advertisement
Acceleration
Inclination
Remote Sensing
Tilt Switching
SINCE
1917
Tilt Sensing Solutions Guide
Since 1917
, Rieker Inc - a worldwide leader in the manufacturing of quality electronic and mechanical inclinometers and tilt sensing instruments – has been committed to customer service, product reliability, on-time delivery, and technical support.
•
Decades of manufacturing experience
•
Stock & Custom made-to-order
•
Electronic & mechanical
•
Made for harsh environments & wide operating temperatures
•
OEMs welcome!
The products in this catalog meet a variety of applications; however, if you have an application that requires custom specifications, please contact us with your requirements.
Call 610-500-2000 today, one of our application experts will be happy to discuss your requirements.
1000 Series Inclinometers
Mechanical “Ball-in-Tube” Tilt Angle Indicators
Page 1 of 2
(Customer Specified Color Zone) Part Number Shown: 1023W1SPL3-10/15/20
Rugged All-weather Accurate Slope Indicators
Instantly Alert the Operator to Out-of-level or Tip-over Danger
Description
Rieker manufactures mechanical inclinometers using precision glass tube and ball construction with engraved markings and customer specified color warning zones. All our tubes are filled with a proprietary damping fluid that controls the movement of the ball for a smooth and error free roll. The fluid combined with large, clear number and degree markings make it easy to get quick, accurate readings under a wide variety of severe environmental conditions.
Applications
Visual Reference of Slope Angle
Roll or Tip-over Prevention
Platform Leveling
Load Balancing
Measuring Degree of Angle or Slope
Equipment Types
Aerial lift trucks, Aircraft, Bucket/Utility trucks,
Cranes, Construction Equipment, Conveyor and
Material Handling Equipment, Emergency and Fire
Aerial Ladder trucks, Government and Military
Vehicles, Marine Vessels, Recreational Vehicles (RV),
Trailers.
Models 1017(-12VT) and 1023(-12VT) comply with
National Fire Protection Association 1901 Standards for Automotive Fire Apparatus.
Features
ALL-Weather - Will Not Rust or Hang Up
Easy Installation – Retrofit in the field
Color Warning Zones – Customizable
Backlit Models – Night Operation
Extreme Shock / Vibration Resistant
UV Resistant
Wide Operating Temperature Range
Custom Color Warning Zones
The color zone or "SPL" models are designed to instantly alert the operator of tip-over danger utilizing highly visible color zones - based on degree settings specified by the customer specified at time of order. See “PART NUMBER CONFIGURATION” on the next page, lower left column in purple.
Backlit Models
These highly visible backlit models use an innovative technique that lights the tube (not the housing) so you can actually see the ball position. Specifically developed for fire trucks that are required to have all instrumentation lighted, the "-12VT" models are well suited for any industry when instrumentation must be visible in low light or night operation.
Available with customer specified color zones right on the tube for best visibility.
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
1000 Series Inclinometers
Mechanical “Ball-in-Tube” Tilt Angle Indicators
Page 2 of 2
CASE MATERIAL
TUBE CONSTRUCTION
OPERATING TEMPERATURE
General Technical Data for 1017 and 1023 Models
ALUMINUM, BLACK PAINTED; ENGRAVED MARKINGS FILLED WHITE
PRECISION GLASS TUBE, DAMPING FLUID FILLED; BLACK BALL
-40°C TO +72°C (-40ºF TO +162ºF)
±5/±10º 1017 Model Ordering Specifications
DIMENSIONS
6"w X 1.625”h" X 0.625"d
±20º 1023 Model Ordering Specifications
DIMENSIONS
5.375"w X 1.75"h X 0.625"d
RANGE
±5°
RANGE
±20°
MARKINGS
0.5°
MARKINGS
5°
RANGE
MARKINGS
±10°
2°
RANGE
MARKINGS
±20°
1°
RANGE
MARKINGS
±10°
1°
RANGE
±10°
MARKINGS
COLOR 1
COLOR 2
PN SHOWN
2°
RANGE
±10°
MARKINGS
COLOR 1
COLOR 2
COLOR 3
PN SHOWN
2°
RANGE
5-0-5
10-5 5-10
1017SPL2-5/10
3.5-0-3.5
8-5
10-8
5-8
8-10
1017SPL3-3.5/8/10
MARKINGS
COLOR 1
COLOR 2
COLOR 3
PN SUBMITTAL
EXAMPLE: 1017SPL3-3.5/8/10
1017 = ba se model (±10º)
SPL = part has custom color zones
2 = number of color zones
-3.5/8/10 = degree range for each color zone (±)
GREEN = safe operation under ±3.5º
YELLOW = warning zone between 3.5 and 8º
RED = unsafe operation over ±8º
RANGE
±20°
MARKINGS
1°
Fluorescent yellow background & engraved markings, visible under UV Light
RANGE
±20°
MARKINGS
COLOR 1
COLOR 2
PN SHOWN
5°
RANGE
±20°
20-10
10-0-10
10-20
1023SPL2-10/20
MARKINGS
COLOR 1
COLOR 2
COLOR 3
PN SHOWN
1°
RANGE
±20°
15-10
20-15
10-0-10
10-15
15-20
1023W1SPL3-10/15/20
MARKINGS
5°
COLOR 1
COLOR 2
COLOR 3
PN SHOWN
8-0-8
12-8 8-12
20-12 12-20
1023SPL3-8/12/20-12VT
NOTE: All 1000 Series are available with color zones. *The
“SPL” models shown are samples of customer specified color zones. Zones dependent upon customer specified degree ranges and colors. Models with custom color zones have extended part numbers - based on degree range and number of zones. If you have any questions on how to create the correct color zone part number, give us a call today for assistance.
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
2000 Series
Mechanical “Ball-in-Tube” Clinometers
Page 1 of 2
Rugged All-weather Angle Indicators for Quick Slope or Heel Position
Up to 12 Feet Away!
Description
A Clinometer is any of various surveying instruments for measuring angles of elevation, slope, or incline, with respect to gravity. Also known as an inclinometer, slope indicator, tilt meter, or gradiometer, these precision instruments provide accurate real-time measurement of slope in Degrees.
Rieker manufactures commercial off-the-shelf mechanical type inclinometers using precision ball in tube construction - each filled with a special damping fluid that controls ball movement, providing a smooth steady roll during static and dynamic applications. The fluid combined with large, clear number and degree markings make it easy to get quick, accurate readings under a wide variety of severe environmental conditions.
Rieker Clinometers are the industry standard - typically used on sail boats and watercraft to indicate small changes in attitude and provide real time angle of the vessel. Other applications include aerial lift/off-road material handlers, cranes, construction equipment, aircraft, submarines, military and government vehicles for pitch and roll indication, balancing and preventing roll-over.
Features
ALL-Weather - Will
Not Rust or Hang Up
Easy Installation –
Field Retrofit
Extreme Shock /
Vibration Resistant
UV Resistant
Wide Operating
Temperature Range
Applications
Visual Reference of
Slope Angle
Roll or Tip-over
Prevention
Platform Leveling
Load Balancing
Measuring Degree of
Angle or Slope
Equipment Types
Aerial lift trucks
Aircraft
Bucket/Utility trucks
Cranes
Construction Equipment
Conveyor and Material
Handling Equipment
Emergency Vehicles
Fire Aerial Ladder trucks
Government and Military
(wheeled or tracked)
Vehicles
Marine Vessels (including sailboats)
Recreational Vehicles (RV)
Trailers
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
2000 Series
Mechanical “Ball-in-Tube” Clinometers
Page 2 of 2
GENERAL TECHNICAL DATA
Case Material
Tube Format
Polycarbonate, IP68
Precision dampening fluid filled, color-coordinated ball
Operating Temperature
-50° F to +180° F (-45ºC to +82ºC)
CLINOMETER PN SPECIFICATIONS
2055 2055E Dimensions
6"w X 2.5"h X 0.375"d
(152,4mm X 63,5mm X 9,6mm)
Degree Range ±60°
Markings
Case Color
5°
White or Black
Dimensions
6"w X 3.75"h X 0.375"d
(152,4 X 95,25 X 9,6mm)
UPPER
SCALE
±6º, 1º steps
Degree Range
LOWER
SCALE
±60º, 5º steps
Case Color
White or Black
Dimensions
6.5"w X 2.375"h X 0.375"d
(165,1 X 60,4 X 9,6mm)
Degree Range
CENTER
SCALE
±10º, 2.5º steps
OUTER
SCALE
±45º, 5º steps
Case Color
White or Black
2056
2058
2056E
2058E
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
2100 Series
Mechanical “Ball-in-Tube” Inclinometers
Page 1 of 2
Rugged Inclinometers for Measuring Slope Angle & Grade
Description
A Clinometer is any of various surveying instruments for measuring angles of elevation, slope, or incline, with respect to gravity. Also known as an inclinometer, slope meter, or gradiometer, Rieker precision instruments provide accurate real-time measurement of slope angle in Degrees and Percent Grade.
Features
ALL-Weather - Will Not
Rust or Hang Up
Easy Installation – Field
Retrofit
Extreme Shock /
Vibration Resistant
Rieker Inc. manufactures commercial off-theshelf mechanical type inclinometers using precision ball in tube construction - each filled with a special damping fluid that controls ball movement, providing a smooth steady roll during static and dynamic applications. The fluid combined with large, clear number and degree markings make it easy to get quick, accurate readings under a wide variety of severe environmental conditions.
UV Resistant
Wide Operating
Temperature Range
Custom Warning Zones
(Red/Green)
Applications
Quick Visual of…
Boom Angle
Rieker Clinometers are the industry standard - typically used to indicate small changes in attitude and provide real time angle of vehicle or equipment under harsh rugged conditions.
Slope Meter
Pitch and Roll
Tip-over Warning
Contact us today for a quote. OEMs welcome, quantity pricing available.
Platform Leveling
Load Balancing
Equipment Types
Aerial lift trucks
Aircraft
Bucket/Utility trucks
Cranes
Construction Equipment
Conveyor and Material
Handling Equipment
Emergency Vehicles
Fire Aerial Ladder trucks
Government and Military
(wheeled or tracked)
Vehicles
Marine Vessels (including sailboats)
Recreational Vehicles (RV)
Trailers
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
2100 Series
Mechanical “Ball-in-Tube” Inclinometers
Page 2 of 2
2126 GENERAL TECHNICAL DATA
6"w X 2.375"h X 0.375"d (152,4mm X 60,4mm X 9,6mm)
Dimensions
Case Material
100% Polycarbonate, IP68
Operating Temperature
-50° F to +180° F (-45ºC to +82ºC)
2126 PART NUMBER SPECIFICATIONS
2126-C
Degree Range
Degree Markings
Background Color
Markings Color
±26°
2°
Black
White
2126-D (Gradiometer)
Percent Range
Degree Range
Background Color
Markings Color
UPPER SCALE
LOWER SCALE
Black
White
±45%, 5%
±26º, 2º
2126-E
Degree Range
Degree Markings
Background Color
±26°
2°
White
Markings Color
Black
Customer Specified Warning Zones
Zone Example*
UPPER SCALE
LOWER SCALE
±25% to 45%
±14 to 26°
Red
Red
Zone Example*
Background Color
Black
White
Markings Color
*Please note that color zones are specified by the customer – your sales representative will be happy to assist.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
4120 Series
Mechanical Boom Angle Indicators
Page 1 of 2
Accurate, Rugged & ALL-Weather
Boom Angle Indicator
Meets OSHA Standards for
Cranes and derricks
Rugged housing withstands weight of SUV
Back lit model meets FEMA regulations for fire apparatus
DESCRIPTION
Rieker's mechanical boom angle indicators are all-weather and will not rust, freeze, or otherwise "hang up" like oldfashioned metal pendulum styles. Like all of our instruments, each indicator is properly dampened for smooth reliable readings.
The housing is designed for easy mounting with two screws, allowing for quick and efficient retrofitting in the field.
With bright, long-lasting LEDs, the backlit models are highly visible for increased safety - especially at night!
APPLICATIONS
The 4120 is recommended for use on any boom where quick accurate inclination measurements must be taken under difficult conditions and harsh environments.
The 4120 meets OSHA Standards for Cranes and derricks and with installation makes the equipment compliant to the standard.
Typical applications include aerial lifts, truck-mounted boom cranes, any fire truck with a mounted boom or ladder, telescoping off-road variable reach fork lifts, cranes and derricks.
FEATURES
Oversized inclinometer for easy read
High visibility markings
Hermetically sealed – will not leak
Weatherproof - will not rust or hang up
UV Resistant
Operational from -50° F to
+180° F
Shock & vibration resistant
Easily installed – quick retrofitting
Right-hand & left-hand models available
12-Volt backlighting - highly visible at night for added safety
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
4120 Series
Mechanical Boom Angle Indicators
Page 2 of 2
Dimensions
TECHNICAL DATA
14"w X 6 3/8"h X 1 3/4"d
Degree Range
Degree Markings
-30° through +90°
5° increments
Case Material
100% Polycarbonate (white or black based on pn)
Tube Construction
Clear tube filled with dampening fluid; precision ball (white or black based on pn)
Operating Temperature
-50° F to +180° F
Backlit Model Operating Voltage
12 Volt
Rieker Boom Angle Indicators comply with current OSHA Standards
OSHA -- Occupational Safety & Health Administration, U.S. Department of Labor
• Part Title: Safety and Health Regulations for Construction
• Subpart Title: Cranes, Derricks, Hoists, Elevators, and Conveyors
<Link below goes to the OSHA web site> http://www.osha-slc.gov/OshStd_data/1926_0550.html
<Then follow these breadcrumbs: > Regulations (Standards - 29 CFR) > PART 1926 Safety and Health Regulations for
Construction > 1926.550 - Cranes and derricks > 1926.550(a)(1)
4120 MODEL ORDERING SPECIFICATIONS
LEFT HAND PART NUMBERS RIGHT HAND PART NUMBERS
4120WWL 412OWWR
White case/white label/black markings
4120WBL
White case/black label/white markings
White case/white label/black markings
4120WBR
White case/black label/white markings
4120BBL
Black case/black label/white markings
4120BBR
Black case/black label/white markings
4120WWL-12V
White case/white label/black markings/backlit
4120WWR-12V
White case/white label/black markings/backlit
Contact us today for a quote. OEMs welcome. Quantity pricing available .
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
5012P Gradiometer
Mechanical “Ball-in-Tube” Grade (Slope) Indicator
Page 1 of 1
Features
Part Number Shown: 5012P “Gradiometer”
Accurate, Rugged Inclinometer for Measuring Slope or Grade
2 Scales: Inch per Ft-Rise and % Grade
Weatherproof - will not rust or hang up
UV Resistant
Extremely shock and vibration resistant
Description
Easily installed – quick retrofitting
Quick and accurate visual reference
Operational from -50° F to +180° F
A Gradiometer is any of various surveying instruments for measuring angles of elevation, slope, or incline, as of an embankment or roadway. Also called clinometer or inclinometer, the 5012P provides accurate measurement of slope in Percent Grade and Inch Per Foot Rise. Rieker manufacturers these manual type gradiometers (or inclinometers) using precise glass tube and ball construction. All our tubes are filled with a special dampening fluid that controls the movement of the ball. The fluid combined with large, clear number and degree markings make it easy to get quick, accurate readings under a wide variety of severe environmental conditions.
Applications
Plows, graders, excavators, trenchers, and pavers are only a few examples of the types of applications well suited for gradiometers.
Contact us today for a quote. OEMs welcome, quantity pricing available.
DIMENSIONS
MEASURING RANGE
CASE MATERIAL
TUBE CONSTRUCTION
OPERATING TEMPERATURE
GENERAL TECHNICAL DATA
8.0"W X 2.875"H X 0.375"D (203,2MM X 73MM X 9,6MM)
UPPER ±1.5 INCH PER FOOT RISE, IN 0.125” (1/8”) INCREMENTS
LOWER ±13% GRADE, IN 1% INCREMENTS
BLACK ACRYLIC, ENGRAVED MARKINGS FILLED WHITE
CLEAR GLASS TUBE FILLED WITH DAMPENING FLUID; BLACK BALL
-50° F TO +180° F (-46ºC TO +82ºC)
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
C Series
Precision Circular “Bulls-Eye” Bubble Levels
Page 1 of 2
Description
Photo Above: C0007 Circular Bubble Level, 2.75” dia.
Also referred to as a “bulls-eye” level, the C Series of
Circular Bubble Levels provide accurate measurement of level in an all-weather machined Aluminum housing (Anodized black). Several sizes available to fit most space limits.
Manufactured to exacting specifications, the accuracy is guaranteed and maintained through the use of precision ground glass and machined Aluminum.
Rigorous testing completed to assure high performance over long-term all weather conditions, exceeding Salt Fog survivability per ASTM B117.
Each instrument is filled with a special damping fluid that controls the movement of the bubble. The background is a metallic silver finish, providing the best contrast for viewing bubble position.
Features
•
ALL-Weather Machined Aluminum Housing
•
Precision Ground Glass – No Discoloration or
Crazing over time
•
Permanently Markings
•
Metallic Silver Background Finish for High
Contrast Visibility of Bubble Position
•
Operating Temperature -40°C to +80ºC
Applications
•
Quick and Accurate Visual Reference
•
Leveling, Balancing and Preventing Tip-over
•
Machining or Anywhere Precise Leveling
Required
These precision circular vials have three mounting holes for installation calibration. Since most mounting surfaces may vary, for exact zero calibration the
C000X-A models all come with mounting hardware.
Equipment Types
•
Aerial lift trucks, Bucket/utility trucks, Cranes
•
Construction Equipment, Conveyor/Material
Handling Equipment
•
Emergency and Fire Aerial Ladder trucks
•
Government and Military Vehicles
•
Recreational Vehicles (RV) and Trailers
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
C Series
Precision Circular “Bulls-Eye” Bubble Levels
Page 2 of 2
GENERAL TECHNICAL DATA
Environmental Testing
Salt-Fog per ASTM B117
Housing Material
Glass Construction
Machined Aluminum, Anodized Black
Precision Ground Glass
Operating Temperature
-40ºC to +80ºC (-40° F to +176° F)
MECHANICAL SPECIFICATIONS
Part #
C0005-A
C0008-A
Sensitivity per
0.1“
C0004-A 45 Minutes
20 Minutes
C0006-A 10 Minutes
C0007-A 10 Minutes
10 Minutes
1
1
4
Concentric Rings Cross Hair
1 --
1 --
--
-- yes
ORDERING SPECIFICATIONS
Outside Dia.
(inches [mm])
1.25 [31,75]
1.44 [36,57]
2.00 [50,8]
2.75 [69,85]
3.15 [80]
Part # Description
C0004-A 1.25" Circular Level, 1 Ring, Mounting Bumper & Hardware
C0005-A 1.44" Circular Level, 1 Ring, Mounting Bumper & Hardware
C0006-A 2.00" Circular Level, 1 Ring, Mounting Bumpers & Hardware
C0007-A 2.75" Circular Level, 1 Ring, Mounting Bumpers & Hardware
C0008-A 3.15" Circular Level, Cross Hair Rings at 0º, 1º, 3º, 5º rings, Jack Springs & Hardware
Contact us today for a quote. OEM pricing available.
Height
(inches [mm])
0.44 [11,17]
0.50 [12,7]
0.68 [17,27]
0.69 [17,52]
0.49 [12,44]
Spare Hardware P/N
E-309
E-309
E-308
E-318
E-348
Photo 1: C000X Series Various Sizes. Photo 2: C0008, 3.15” dia, 4 Concentric Rings
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
B Series
General Specifications Brochure
Page 1 of 2
Compact Static Accelerometer:
for acceleration or angle measurement in frequency ranges 0Hz to 550Hz.
Description
The B1, B2, and B3 sensors are capacitive spring mass accelerometers with integrated sensor electronics. Requiring very low power consumption these are characterized by a high degree of longterm stability. Resonant peaks are minimised by means of a special gas-dynamic damping in the primary transformer.
Manufactured with an Analog DC output, the integrated sensor electronics require only minimal power and are in conjunction with the capacitive primary transformer characterized by high accuracy, linearity, and long-term stability.
Applications
The B Series are used for applications requiring high overload tolerance, high long-term stability, small lower cut-off frequency down to measurement of static acceleration, very short on-transition delay and low power consumption.
Typical applications include: measurements on vehicles, machinery, buildings, and plants for process control and error diagnosis seismic measurements inclination measurements (i.e. ±90º) safety engineering dynamic measurement of position & velocity
Housing
Protection Degree
Mounting
Mounting Plane
Outline Dimensions
Electrical
Connection
Standard
Optional
Weight
Operating Temperature
Storage temperature
Features
Compact housing, less than 1” diameter
Very high overload resistance
Insensitive to interference by magnetic and electric fields
Lower cut-off frequency is zero, hence suitable for measuring static acceleration, such as gravity
(inclinations) or radial acceleration
(centrifugal force)
Linear frequency response with little or no resonant peak at upper cut-off frequency
Low non-linearity
High signal-to-noise ratio
No measurable hysteresis of signal
Hermetically sealed
High long-term stability
Small temperature drift
Integrated sensor electronics
Analog DC or pulse width modulated or frequency modulated output
Low power consumption
Very short settling time
Multiple housing options
MECHANICAL CHARACTERISTICS
Nickel Plated Brass
IP65
M4 Mounting Stud, M3 optional
See “Figure 1”
Ø 0.945” (Ø 24mm) X .434” (11mm) h
3 highly flexible, color-coded wires Ø 0.04” (Ø 1.0mm) x 7.0” (18cm)
A: Shielded cable Ø 0.083” (Ø 2.1mm) x 1.65’ (0.5m)
B: 3 highly flexible, single color wires with Teflon isolation for extended temperature range
Approx. 0.89 ounces (25 grams) (not including cable)
-40°F to +185°F (-40° to +85°C ), optional +257ºF (+125ºC)
-49°F to +194°F (-45° to +90°C ), optional +257ºF (+125ºC) voice: 610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 email: [email protected]
web: www.riekerinc.com
B Series
General Specifications Brochure
Page 2 of 2
TYPE
Measuring Range
Resolution
Frequency Range
Max. Non-linearity
Cross Axis Sensitivity
Mechanical Overloading in
Measuring Direction
Power Supply U bN
(Regulated)
Min ... Max. Supply U bz
Current Consumption U b
=5Volt
B1
±3g (Approx. ±30m/s
2
)
B2
±10g (Approx. ±100m/s
2
)
B3
±50g (Approx. ±500m/s
2
)
<.001g <.005g <.020g
0…160Hz 0…350Hz 0…550Hz
<0.5%
<1%
10,000g (Approx. 100,000m/s
2
)
Sensitivity
Temperature Drift of Sensitivity
Temperature Drift of Zero
5 Volt
3 ... 6 Volt
Approx. 1mA
ANALOG VOLTAGE OUTPUT MODEL AT U
BN
=5VOLT
Approx. 110mV/g Approx. 23mV/g
< +0.06%/°C
< 0.1mV/°C
Approx. 6.5mV/g
Zero Offset at Ub=5V 2.5 ±0.1 Volt - generally: 0.5Ub ±4%
Output Impedance 10k
Ω
Digital pulse-width modulated output signal - linear to the degree of angle - available upon request.
CABLE WIRING TABLE:
RED
WHITE
BLUE
3-WIRE (standard)
+5VDC Stable
Output Signal
GND (housing)
RED
BLUE
SHIELD
SHIELDED CABLE (optional)
+5VDC Stable
Output Signal
GND (housing)
ATTENTION! The supply voltage must not exceed 6 Volt and the polarity must not be reversed.
Figure 1:
Dimensions and Mounting Position ([mm])
voice: 610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 email: [email protected]
web: www.riekerinc.com
BDK Series
General Specifications Brochure
Page 1 of 2
Compact Accelerometer:
for Dynamic Measurement of
Acceleration or Vibration in
Frequency Ranges 1Hz to 1.5kHz.
Description
BDK sensors are dynamic accelerometers that are capacitive spring-mass based, with incorporated sensor electronics. Resonance peaks are minimised by means of a special gas-dynamic damping in the primary transformer. With very low power consumption, these sensors are characterised by very low drift (or error) and long-term stability.
Applications
These accelerometers are used for applications requiring high overload tolerance, high long-term stability, small lower cut-off frequency, light weight and low power consumption.
Typical applications include: measurements on vehicles, machinery, buildings, and plants for process control and error diagnosis seismic measurements vibration measurements safety engineering dynamic measurement of position & velocity
Features
Compact housing, less than 1” diameter
Light weight
Very high overload resistance
Insensitive to interference by magnetic and electric fields
Low cut-off frequency
Linear frequency response with little or no resonant peak at upper cut-off frequency
Low non-linearity
High signal-to-noise ratio
Very low cross-axis sensitivity
Hermetically sealed
High long-term stability
Small temperature drift
Integrated sensor electronics
Long connection leads available
Multiple housing options
6 1 5 0 2 0 0
0
Type 1
Type 2
Type 1
Type 2
Type 1
Type 2
Standard
Optional
MECHANICAL CHARACTER ISTICS
Stainless Steel, M6 Mounting Stud
Nickel Plated Brass
Ø 0.87” (Ø 22mm) X 0.39” (10mm) h
Ø 0.80” (Ø 20mm) X 0.30” (7,5mm) h
Approx. 0.60 ounces (17 grams)
Approx. 0.25 ounces (7 grams)
IP65
See “Figure 1”
See “Figure 1”
3 highly flexible, color-coded wires Ø 0.04” (Ø 1.0mm) x 7.0” (18cm)
Type 1 Housing: Shielded cable Ø 0.083” (Ø 2.1mm) x 1.65’ (0.5m)
-40°F to +185°F (-40° to +85°C )
-49°F to +194°F (-45° to +90°C )
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
BDK Series
General Specifications Brochure
Page 2 of 2
Me chanical Overloading in
±3g (Approx. ±30m/s
2
)
<10
-3 g
1…300Hz
±10g (Approx. ±100m/s
2
) ±100g (Approx. ±1000m/s
2
)
<5*10
-3 g <5*10
-2 g
1…800Hz 1…1500Hz
<0.5%
<1%
10,000g (Approx. 100,000m/s
2
)
5 Volt
2 ... 16 Volt
BD: Approx. 250uA (optional 30uA), BDK: Approx. 2mA
ANALOG VOLTAGE OUTPU T
Approx. 150mV/g Approx. 60mV/g Approx. 10mV/g
< +0.06%/°C
< 0.1mV/°C
Zero Offset at
Ub=5V 2.5 ±0.1 Volt - generally: 0.5Ub ±4%
100 Ohm
Digital pulse-width modulated output signal - linear to the degree of angle - available upon request.
+5VDC Stable
Output Signal
GND (housing)
+5VDC Stable
Output Signal
GND (housing)
ATTENTION! Do not reverse voltage operating polarity!
Figure 1: Dimensions and Mounting Position ([mm])
6 1 5 0 2 0 0
0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
BS24
Sensor Mounting Cube
Page 1 of 1
Allows mounting up to five
(5) sensors for multi-axis acceleration and/or inclination measurements.
Available in Delrin (POM) plastic or Aluminum.
Compatible with the following Seika sensors:
•
NB3 Inclinometer
•
Note:
B1, B2, and B3 Accelerometers
•
Sensors sold separately
•
Sensor must be ordered with the M4 mounting stud option.
Plastic (Polyoxymethylene)
Aluminum
Figure 1: BS24 Dimensions (in millimeters)
.65 Ounces (18.5 Grams)
1.13 Ounces (32 Grams)
6 1 5 0 2 0 0
0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 n q yy
@riekerinc.com
w w w
CARS
™
Brochure
Curve Advisor
y Reporting Service
Features
•
Safe & Continuous Operation o
1 Pass each direction o
With Traffic
•
•
•
•
•
•
•
•
•
•
•
•
FHWA Compliant
Meets Federal MUTCD
Requirements
Integrated GPS
Key Data Collection o
Curve Radius o
Super Elevation o
GPS coordinates o
Date/Time
USB Connectivity
Secure Online Data Storage
Automated Curve Speed
Calculations
Printable Reports
Adjustable Trip Angle Setting
Auto Leveling
Dash Mount Quick Installation
Portable Multi-vehicle Use
Rieker Total Solutions:
Curve Advisory
Reporting
Service
CARS™ is a integrated
Road Survey system, with internal GPS, that will automatically record and determine recommended safe curve speed along with the curve radius and super elevation. This system will allow a driver to continuously survey miles of roads over hours of driving in a day without stopping. Road telemetry is recorded to the tablet as a permanent record for later analysis.
One pass each direction, with traffic at any speed - get the job done safer, faster and
FHWA MUTCD compliant.
Accurate, Safe and Efficient
Based on the Federal Highway Administration (FHWA) guidelines on how to determine safe curve speed, our new system allows the operator to simply drive as many miles of road in a day as needed, even stop & go rush hour traffic! Review and analyze individual curve data after a road has been surveyed, or anytime on any computer. No need for constant speeds or manual data input, making the job safer, faster, and under budget. Automatic calculation of the Safe Curve Advisory Speed to meet MUTCD requirements.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
CARS
™
Brochure
Curve Advisory Reporting System
Page 10 of 10
CARS Solution…
• SAFETY FIRST – Allows driving with traffic – any speed.
• CONSISTENCY – Meets FHWA MUTCD requirements.
• ON-TIME Project Completion – Reduces time in the field, analyzing data and creating reports.
• BUDGET SAVINGS – Saves man hours, reduces safety risk.
Find out more: http://www.riekerinc.com/CurveAdvisoryReporting.htm
Or call us today at: 610-500-2000
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
H4 Series
General Information Brochure
Page 1 of 4
Rugged ALL-weather
Inclinometer Providing
Analog Voltage (0…5VDC) or Digital Serial (RS232)
Output.
Description
The H4 Series of inclinometers provide single axis inclination sensing in a rugged environmentally protected metal housing. The sensing package incorporates a liquid capacitive sensing element and integrated temperature compensation over the industrial operating range of –40° to +85°C.
These sensors are available with a choice of two output configurations, analog voltage or digital serial outputs. These outputs are linear with respect to the input angle directly.
Digital Serial (RS232) Output
The Serial output (RS232) transmits the degree of angle in a decimal format. This output provides a continuous stream of readings - one reading per line at approximately 250msec per reading. The H4 transmits the output to a computer through its serial port, using HyperTerminal as the interface.
The unit is configured for 9600 baud, 8 data bits, no parity, 1 stop bit.
Features
Single Axis Angle Measurement
3 Ranges: ±30°, ±45º, ±70°
Temperature Compensated
Analog Voltage 0…5V Output
Serial Digital RS232 Output
Vibration and shock resistant
Environmentally sealed to IP67
Rugged die-cast Zinc housing
EMC protected
Mechanical Zero adjustment
Common footprint for easy field install
Applications
Platform Leveling
Vehicle Tilt Monitoring
Antenna Positioning
Boom Angle Indicating
Process Machinery
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 inquiry@riekerinc.com
www .riekerinc.com
H4 Series
General Information Brochure
Page 2 of 4
Technical Specifications
MEASURING RANGES
MEASUREMENT AXIS
POWER SUPPLY
NON-LINEARITY
1
NULL REPEATABILITY
TRANSVERSE SENSITIVITY
SENSOR ELEMENT RESPONSE TIME
BANDWIDTH
OPTIONAL TEMPERATURE
COMPENSATION OUTPUT DRIFT
INPUT PARAMETERS
±30°, ±45º, ±70°
Single
8…30 VDC Non-Regulated
OUTPUT PARAMETERS
optional 5VDC Regulated
< 0.5% Full Range for ±30º model
< 0.2% Full Range for ±45º, ±70º models
< 0.05°
< 1.0% at 30º Tilt
< 0.3 seconds (<300mSec)
3 Hz
< ±1.0° (over full operating temperature range)
TEMPERATURE RANGE
-40ºF to +185ºF (-40°C to +85°C)
-49ºF to +194ºF (-45°C to +90°C)
OPERATING TEMPERATURE
STORAGE TEMPERATURE
ANALOG (0…5V) OUTPUT
ZERO OFFSET
ANALOG VOLTAGE OUTPUT (Linear Range)
OUTPUT VOLTAGE SENSITIVITY
±30º
±45º
±70º
ACCURACY OVER TEMPERATURE
±30º
±45º
±70º
RESOLUTION
±30º
±45º
±70º
CURRENT CONSUMPTION
OUTPUT IMPEDANCE
DIGITAL (RS232) OUTPUT
±30º
±45º
±70º
CURRENT CONSUMPTION
RS232 OUTPUT FORMAT
BAUD RATE
DATA BITS
PARITY
STOP BITS
TRANSMISSION RATE
Temperature Compensation
Over full operating temperature range
2.5VDC typical
0.5…4.5VDC
66.7mV/º
44.4mV/º
28.6mV/º
< ±0.5º
< ±0.5º
< ±1.0º
< 0.02º
< 0.03º
< 0.04º
10mA typical
< 100 OHMS
Temperature Compensation
Over full operating temperature range
< ±0.5º
< ±0.5º
< ±1.0º
10mA typical
ASCII Decimal
9600
8
None
1
Continuously updated every 25mSEC
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 inquiry@riekerinc.com
www .riekerinc.com
H4 Series
General Information Brochure
Page 3 of 4
HOUSING
ENVIRONMENTAL RATING
MOUNTING HOLES
MOUNTING PLANE
OUTLINE DIMENSIONS
ELECTRICAL CONNECTION
WEIGHT
MECHANICAL CHARACTERISTICS
Die Cast Zinc
IP67
Two #6-32
Vertical Surface
Ø1.95” x 1.1” (Ø49.5 x 28mm) See Drawing
1ft. Teflon Cable with 3 pigtail leads
8 ounces (227 grams)
Notes: 1. Non-linearity generated by best fit straight line using least squares regression. Output is linear with respect to the input angle directly.
Figure 1: Dimensions (inches [mm]) and Wiring Connections
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 inquiry@riekerinc.com
www .riekerinc.com
H4 Series
General Information Brochure
Page 4 of 4
TABLE 1: Part Number for Ordering Information
P ART NUMBER MATRIX CHART
H 4
OPTION
CODE
4
N/A
HOUSING
MACHINED ZINC METAL (Default)
ALTERNATIVE HOUSING
OUTPUT
ANALOG
DIGITAL SERIAL (RS232)
TEMPERATURE COMPENSATION
LEVEL 1
A
S
1
ANGLE RANGES
“XX” = ±30º, ±45º, ±70º
SPECIAL SCALING
INPUT POWER
8 TO 30VDC (Default)
5VDC
MODEL NUMBER
STANDARD (or stock) CONFIGURATION (Default)
CUSTOM SPECIAL: “-X” = LETTER ASSIGNED AT TIME OF ORDER
“XX”
N/A
BLANK
V
BLANK
“-X”
A 1 - 30 -
As shown above the part number H4A1-30 represents a single axis unit with a ±30º measuring range, Analog output, Level 1 Temperature Compensation, 8 to 30VDC supply power.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 inquiry@riekerinc.com
www .riekerinc.com
Flex Series H4360
General Information Brochure
Page 1 of 4
Accurate, Rugged,
ALL-weather 360 Degree inclinometer provides
Analog Current 4..20mA
& Digital RS485 outputs.
H4360
Description
The highly accurate H4360 inclinometer provides
360 degree total measurement along a single axis in a rugged environmentally protected metal housing.
The sensing package incorporates a MEMs sensing element and integrated temperature compensation over the industrial operating range of –40° to +85°C.
This sensor is available with analog current 4..20mA and digital RS485 outputs. These outputs are linear with respect to the input angle directly. Depending on the required angle range, the H4360 measuring range can be scaled anywhere along the range.
The output parameters can be modified at the factory to meet your speciications (ie range, polarity). We also offer the Flex Series Development
Kit allowing the end customer to modify the sensor as needed right from a PC – providing full flexibility for R&D and OEM production lines.
Features
Single Axis Angle Measurement
Measuring Range: ±180 (360º Full Scale)
Fully Temperature Compensated
Analog Current 4..20mA Output
Serial RS485 Output
Vibration and shock resistant
Environmentally sealed to IP68
Rugged die-cast Zinc housing
EMC protected
Over voltage/overcurrent protection
Mechanical Zero adjustment
Common footprint for easy field install
Applications
Platform Leveling
Solar Panel Array Alignment
Antenna Positioning
Boom Angle Indicating
Process Machinery
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
Flex Series H4360
General Information Brochure
Page 2 of 4
Technical Specifications
MEASURING RANGE
MEASUREMENT AXIS
POWER SUPPLY
4..20MA
RS485
SENSOR ELEMENT RESPONSE TIME
START-UP TIME
INPUT PARAMETERS
360º (optional scaled ranges)
Single
11..36VDC Non-Regulated
11..36VDC Non-Regulated
OUTPUT PARAMETERS
< 0.3 Sec
< 1 Sec
TEMPERATURE RANGE
-40ºF..+185ºF (-40°C..+85°C)
-49ºF..+194ºF (-45°C..+90°C)
OPERATING TEMPERATURE
STORAGE TEMPERATURE
ANALOG CURRENT 4-20mA
ZERO OFFSET
OUTPUT (LINEAR RANGE)
OUTPUT CURRENT SENSITIVITY
ACCURACY OVER TEMPERATURE
RESOLUTION
CURRENT CONSUMPTION (NO LOAD)
DIGITAL RS485
Temperature Compensated Output
12mA
4..20mA
Relative to scaled degree range
±0.1° Typical / ±0.2º Max
0.05º
37mA @ 12VDC 23mA @ 24VDC
Temperature Compensated Output
ISOLATION
H4360 BAUD RATE
DATA BITS
PARITY
STOP BITS
CHECKSUM
INFORMATION RATE
Non-isolated, -7..+12VDC common mode
125 Kilobaud
8
None
1
CRC16
Polled
HOUSING
MOUNTING HOLES
MOUNTING PLANE
OUTLINE DIMENSIONS
ELECTRICAL CONNECTION
CONNECTOR
MATING CONNECTOR
WEIGHT
MECHANICAL CHARACTERISTICS
Die Cast Zinc, IP67
Two #6-32
Vertical Surface
Ø1.95” x 1.1” (Ø49.5 x 28mm) See Drawing
10” Shielded TFE Teflon 6 conductor 22 AWG Cable
Deutsch DTM04-6P-E005
Deutsch DTM06-6S-E005
8 ounces (227 grams)
Notes: Output is linear with respect to the input angle directly.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
Figure 1: Mounting Position and Dimensions (inches [mm])
Flex Series H4360
General Information Brochure
Page 3 of 4
COLOR
RED
BLACK
WHITE
ORANGE
GREEN
BLUE
CONNECTOR WIRING TABLE:
FUNCTION
SUPPLY VOLTAGE +11 TO +36VDC
POWER/SIGNAL COMMON
4..20MA OUTPUT
RS485-A
RS485-B
NO CONNECTION
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
PIN
1
2
3
4
5
6
Flex Series H4360
General Information Brochure
Page 4 of 4
Figure 2: Wiring Diagram met:
H4360 CURRENT SENSE
Rsense is dependent upon supply voltage and cable/wire resistance. Ensure the following equation is
QUICK REFERENCE
SUPPLY VOLTAGE SENSE RESISTOR
12V
24V
200-350 OHMS
200-1000 OHMS
Rsense <= Vsupply - 2.5 - Rwire
0.020
28V 200-1000 OHMS
ACCESSORIES AVAILABLE (Sold Separately)
Interface Cable o
Input power / outputs o
Stock lengths and OEM custom lengths available o
Includes mating connector to sensor, with pigtail leads
Flex Series Development Kit o
Flexware
TM
Toolkit Application o
USB Interface Cable from Sensor to PC o
AC Wall Adaptor
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
H5 Series
General Information Brochure
Page 1 of 3
Rugged, Temperature
Compensated Single Axis
Inclinometer provides Analog
0…5V & 0…10V Outputs simultaneously or Digital
Serial (RS232) output, in angle ranges up to ±90º.
Description
The H5 Series of inclinometers provide single axis inclination sensing in a rugged environmentally protected metal housing.
These sensors are available with a choice of two output configurations, analog voltage or digital serial outputs. These outputs are linear with respect to the input angle directly. The sensing package incorporates a liquid capacitive sensing element with integrated temperature compensation over the industrial operating range of –40° to +85°C.
The Analog version provides both 0…5V and 0…10V outputs with 12…30VDC input voltage. An individual wire for each output is provided, allowing use of both at the same time.
The Serial output (RS232) transmits the degree of angle in a decimal format. This output provides a continuous stream of readings - one reading per line at approximately 250msec per reading. The H5 transmits the output to a PC’s serial port, using
HyperTerminal as the interface – HyperTerminal is a program included with Windows 95, 98, 2000.
Features
Single Axis Angle Measurement
4 Ranges: ±30º, ±45º, ±60º, ±90º
Temperature Compensated Output
Analog Output: 0-5V and 0-10V
Digital Ouput: Serial RS232
Vibration and Shock Resistant
ALL-Weather IP67 Housing
Rugged Machined Aluminum Housing
EMC Protected
Mechanical Zero Adjustment
Common footprint for easy field install
Applications
Platform Leveling
Vehicle Tilt Monitoring
Antenna Positioning
Boom Angle Indicating
Process Machinery
Potentiometer-like Replacement
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
H5 Series
General Information Brochure
Page 2 of 3
INPUT PARAMETERS
MEASURING RANGES
MEASUREMENT AXES
POWER SUPPLY
CURRENT CONSUMPTION
TEMPERATURE RANGE
OPERATING TEMPERATURE
STORAGE TEMPERATURE
ANALOG OUTPUT
ZERO OFFSET
ANALOG VOLTAGE OUTPUT
±30º
±45º
±60º
±90º
±30º to ±90º
±30º
±45º
±60º
±90º
OUTPUT POLARITY
RESPONSE TIME
BANDWIDTH
SERIAL OUTPUT (RS232)
OUTPUT FORMAT
BAUD RATE
DATA BITS
PARITY
STOP BITS
TRANSMISSION RATE
±30º to ±90º
RESOLUTION
MECHANICAL CHARACTERISTICS
HOUSING
MOUNTING HOLES
MOUNTING PLANE
OUTLINE DIMENSIONS
ELECTRICAL CONNECTION
WEIGHT
±30°, ±45º, ±60, ±90º
Single
ANALOG
12-30VDC Non-reg (4-10VDC opt)
10mA typical, 17mA max
SERIAL
8-30VDC Non-regulated
15mA typical
-40°C to +85°C
-45°C to +90°C
Output 1 (0..5V)
Output 2 (0..10V)
2.5VDC TYP
±2.25VDC
5VDC TYP
±4.5VDC
OUTPUT VOLTAGE SENSITIVITY
75mV/º
50mV/º
150mV/º
100mV/º
37.5mV/º
25mV/º
75mV/º
50mV/º
TOTAL ERROR OVER TEMPERATURE
< ±0.5º
RESOLUTION
< 0.02º
< 0.03º
< 0.03º
<0.05º
Output increases with counter-clockwise rotation
<0.3 seconds
3 Hz
ASCII Decimal
9600
8
None
1
Continuously updated every 250mSEC
TOTAL ERROR OVER TEMPERATURE
< ±0.5º
0.1º
Anodized Aluminum (Black), IP67
Four #4-40 X 0.3” Deep
Vertical Surface
Ø2.52” x 1.1” (Ø64mm x 28mm) See Drawing
1ft. FEP Insulated Cable with Four 22 Gauge Pigtail Leads
7.5 ounces
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
Figure 1: Dimensions and Wiring Connections
H5 Series
General Information Brochure
Page 3 of 3
WIRE
COLOR
RED
BLACK
GREEN
WHITE
ANALOG CABLE
WIRING
SERIAL CABLE WIRING
FUNCTION
Input Power
Power/Signal Common
Input Power
Power/Signal Common
Analog Output 1 (0-5VDC) RS232 Output
Analog Output 2 (0-10VDC) No Connection
PART NUMBER MATRIX CHART
HOUSING
MACHINED ALUMINUM (ANODIZED BLACK)
OUTPUT
ANALOG
DIGITAL SERIAL (RS232)
TEMPERATURE COMPENSATION
LEVEL 1
ANGLE RANGES
“XX” = ±30º, ±45º, ±60º, ±90º
INPUT POWER
12- 30VDC (Analog) / 8-30VDC (Serial)
4-10VDC
MODEL NUMBER
STANDARD CONFIGURATION
CUSTOM SPECIAL: “-X”
Default
Default
Default
H 5 A 1 - 60 -
OPTION
CODE
5
A
S
1
“XX”
BLANK
V
BLANK
“-X”
As shown above the part number H5A1-60 represents the following configuration: single axis unit with a ±60º measuring range, Analog output (BOTH 0…5V AND 0…10V OUTPUTS), Level 1
Temperature Compensation, 12 to 30VDC supply power.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
Flex Series – H6
General Information Brochure
Page 1 of 4
User-Configurable,
Accurate All-in-One
Inclinometer
DESCRIPTION
The H6 inclinometer provides dual axis inclination sensing in a rugged environmentally protected housing.
This unit incorporates a MEMS sensing element referenced to gravity with integrated temperature compensation over the industrial operating range of
-40° to +85°C.
The H6 provides a continuous analog current 4..20mA output and a selectable digital output of a polled RS-485 half–duplex (2-wire) output. Available upon request, the
H6 is CAN ready with customer specified protocols. All outputs are linear with respect to the input angle directly.
Used as integrated devices by original equipment manufacturers (OEMs) or as standalone sensors for test and measurement, the H6 is made for applications where high accuracy and long-term stability are required in noisy and wide temperature changing environments.
The output parameters can be modified at the factory to meet your specifications (i.e. range, polarity). We also offer the Flex Series Development Kit allowing the end customer to modify the sensor as needed right from a PC – providing full flexibility for R&D and OEM production lines.
For use with most all applications including commercial, industrial, military applications.
FEATURES
Dual Axis
Scalable Angle Range up to ±180°
Temperature Compensated
Outputs: o o
Analog Current 4..20mA
Digital RS-485
Outputs Optional: o
CAN o
Open Collector Switch
Daisy-chain Multiple Sensors
Vibration and shock resistant
Environmentally sealed IP68
Rugged metal housing
EMC protected to 100V/m
Overvoltage/overcurrent protection
-40° to +85°C Operating
Temperature
CE Certificate of Conformance
APPLICATIONS
Platform Leveling
Solar Panel Array Alignment
Vehicle Tilt Monitoring
Antenna Positioning
Boom Angle Indicating
Process Controls
INDUSTRIES
Aerospace & Defense
Construction
Energy
Mining
Offshore
Transportation
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
Flex Series – H6
General Information Brochure
Page 2 of 4
SUPPLY VOLTAGE
TABLE 1: H6 SENSOR SPECIFIATIONS
INPUT PARAMETERS
+12..36 VDC Non-Regulated
22mA @ 24VDC (Digital Output only)
SUPPLY CURRENT
1
30mA @ 24VDC (Analog Output - no load)
75mA @ 24VDC max (Analog and Digital Outputs enabled)
85mA @ 12VDC max (Analog and Digital Outputs enabled)
Scalable To ±180°
ANALOG MEASURING RANGE
DIGITAL MEASURING RANGE
INPUT PROTECTION
RANGE: ±180°
±180°
Reverse Polarity, ESD & Surge Protected
ABSOLUTE ACCURACY OVER FULL OPERATING TEMPERATURE
±0.1º
OUTPUT TYPE
SENSITIVITY
2
NULL (0º)
RESOLUTION
FREQUENCY RESPONSE
OUTPUT TYPE
INCLINATION OUTPUT
BAUD RATE
BYTE FORMAT
PACKET FORMAT
INFORMATION RATE
OPERATING TEMPERATURE
STORAGE TEMPERATURE
CURRENT OUTPUT PARAMETERS
Factory Default: 4..20 mA (Configurable within 0..24mA)
Relative to Scaled Range
Factory Default: 12 mA Nominal (User Configurable)
0.05º Max
0.5Hz Nominal
DIGITAL OUTPUT PARAMETERS
RS-485 Half Duplex (2-wire)
IEEE Packetized 32-Bit Float
125K Default (Configurable within 9600 to 250K)
8 Data Bits, No Parity, 1-stop Bit, No Flow Control, CRC16 Checksum
See Installation Guide for Packet Details and Commands
Polled (up to 20 times/sec)
TEMPERATURE RANGES
-40ºF..+185ºF (-40ºC..+85ºC)
-49ºF..+194ºF (-45ºC..+90ºC)
MECHANICAL CHARACTERISTICS
HOUSING
WEIGHT
MOUNTING HOLES
MOUNTING PLANE
OUTLINE DIMENSIONS
ELECTRICAL CONNECTION
Aluminum, IP68, All-weather, Submersible
18.6 oz. (525 Grams)
Accept #8 or M4.5 screws (See Dimensional Drawing)
Flat Horizontal Surface
4.34” x 3.26” x 1.8”
See Electrical Connection Drawing
Notes: 1. Supply Current varies depending on outputs connected. Digital output only assumes analog output section is always active however current loop is not connected. 2. Sensitivity defined as (max current range) / (sensor input range).
Ex, A current range set to 4..20mA with a ±30° input range will have a corresponding sensitivity of 16mA/60° or 0.267mA/°.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
Flex Series – H6
General Information Brochure
Page 3 of 4
FIGURE 1: Dimensions (inches [mm]) and Mounting Position
Mounting surface o Dual axis Horizontal surface only.
o Single Axis Vertical surface (must be specified at time of order).
Zero position connector facing user (see FRONT/SIDE VIEW of drawing below)
X axis clockwise (connector to the right and down) tilt “+” (see SIDE VIEW of drawing below)
Y axis clockwise tilt “+” (see FRONT VIEW of drawing below)
1.63
[41,4]
0.89
[22,58]
0.32
[8,13]
Ø 0.196
[4,98]
(4 PLCS)
R 3.815 REF
[96,9]
0.295
[7,49]
TOP VIEW
BOTTOM VIEW
3.75
[95,25]
X
Y
3.618
[91,9]
3.71
[94,23]
SERIAL NUMBER
AND
SENSOR CONFIGURATION
LOCATION
M12 Male
(8-Pin)
Connector
Ø 0.196
[4,98]
(2 PLCS)
-
+
FRONT VIEW (Y-AXIS)
M12 Female
(5-Pin)
Connector
-
+
SIDE VIEW (X-AXIS)
3.26
[82,8]
Mounting Position - Horizontal Surface
4.34
[110,24]
European Compliance Statement:
This product complies with the requirements of European Directives 2004/108/EC.
1.80
[45,72]
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
Flex Series – H6
General Information Brochure
Page 4 of 4
4
5
6
7
8
PIN
1
2
3
TABLE 2: MALE 8-PIN INPUT CONNECTOR
FUNCTION
SUPPLY VOLTAGE +11.. +36VDC
POWER / SIGNAL COMMON
RS485 D+ OR CAN HI
RS485 D- OR CAN LO
CAN SHIELD
X AXIS 4..20MA CURRENT OUTPUT
Y AXIS 4..20MA CURRENT OUTPUT
NO CONNECTION
TABLE 3: FEMALE 5-PIN OUTPUT CONNECTOR
FUNCTION PIN
1
2
3
CAN SHIELD
SUPPLY VOLTAGE +11..+36VDC
POWER COMMON
4
5
RS485 D+ OR CAN HI
RS485 D- OR CAN LO
TABLE 4: CURRENT SENSE
QUICK REFERENCE
Rsense is dependent upon supply voltage and cable/wire resistance. Ensure the following equation is met:
SUPPLY VOLTAGE
Rsense <= Vsupply - 2.5 - Rwire
0.020
12V
24V
28V
TABLE 5: ACCESSORIES (SOLD SEPARATELY)
SENSE RESISTOR
200-350 OHMS
200-1000 OHMS
200-1000 OHMS
FLEX SERIES DEVELOPMENT KIT
TM
•
Flexware Toolkit Application
•
USB Interface Cable from Sensor to PC
•
AC Wall Adaptor
INTERFACE CABLE
•
Input power / outputs
•
Both 8-pin and 5-pin available
•
Stock lengths and OEM custom lengths available
•
Includes mating connector to sensor, with pigtail leads
Display Box
•
Single or Dual Line LCD
•
0.1º Resolution
•
Battery or 12..24VDC input supply
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
DB1C DISPLAY
General Specifications Brochure
Page 1 of 2
LCD Display Box
Provides 360 Degrees of Angle from Remote
Sensor NG360, SB360 or XB360
Description
This Display box is used to display the tilt angle of a single
NG360 - also compatible with the SB360 or XB360 sensor. It is designed for indoor and outdoor use.
Applications
Typical areas of application include construction, mining, vehicles, aircraft, ships, surveying equipment, and transportation and conveyor systems.
Features
Die-cast Aluminium housing (IP65) with saltwater proof coating
Backlit LCD
0.01° Resolution
Full 360° Angle Sensing
0...360° or ±180° display
(depending on state of solder bridge)
RS485 Output of Angle
Zero point can be set by shunting an internal contact and persists after power off
Connects direct to NG360, SB360,
XB360 sensor (converter not required)
MEASURING RANGE
RESOLUTION
TERMINALS
TECHNICAL SPECIFICATIONS
360º (±180º optional configuration)
0.01º
3 x 1.5 mm
2
for power supply and 4 x 1,5mm
2 for sensor
POWER SUPPLY
ENVIRONMENTAL PROTECTION
CABLE FIXING
ORIENTATION OF CABLE FIXINGS
OUTLINE DIMENSIONS
BACKLIGHT
WEIGHT
OPERATING TEMPERATURE
MAX DISTANCE TO SENSOR
12 V (24V optionally) ca.120mA (both Display and Sensor)
IP65
Two M12 x 1.5 cable gland, cable diameter 6mm … 7.5mm
Both cable fixings at bottom side.
Alternatively, one fixing at the left and the other cable fixing at the right side.
2.52” (64mm) W X 3.86” (98mm) L x 1.42” (36mm) H
LED, white
Approx. 16 ounces (454 grams)
-40°F to +149°F (-40° to +65°C )
3281 FT. (ca. 1 km)
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
Figure 1:
Connection and Programming
DB1C DISPLAY
General Specifications Brochure
Page 2 of 2
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
NB3 Series
General Specifications Brochure
Page 1 of 2
Compact Inclinometer Sensors:
NB3 (0…7 Hz) & NB3S (0…60 Hz)
provide High Accuracy for Small
Measuring Ranges within ±10º
Description
The NB3 is a static accelerometer (utilized as an inclinometer) with a high degree of accuracy for measuring small tilt angles of any object with respect to gravity. The sensor's primary transformer consists of a capacitive spring-mass system with gasdynamic damping.
Manufactured either with an Analog DC or a Pulse
Width Modulated (PWM) output, the integrated sensor electronics require only minimal power and are in conjunction with the capacitive primary transformer characterized by high accuracy, linearity, and long-term stability.
Applications
Well suited for industrial use where the demands for compact inclinometers with good long-term stability
(very low power consumption) and relatively small tilt angle measuring ranges (±10º) are preferred.
Typically used for automation and inspections applications as well as safety engineering, medical
& communications equipment, and leveling systems.
Features
Small compact housing, less than 1” diameter
0.3 or 0.01 Second Response Time
Linear output characteristics
Minimal zero offset drift
Hysteresis free measuring signal
High measurement accuracy
Very low relative linearity errors
High long-term stability
Analog or PWM output signals
Very low power consumption
Hermetically sealed housing to IP65
Low transverse sensitivity over full
range
Housing
Mounting
Mounting Plane
Outline Dimensions
Electrical Connection
Weight
Operating Temperature
Storage temperature
MECHANICAL CHARACTERISTICS
Nickel Plated Brass
M3 Mounting Stud, M4 optional
Vertical Surface
Ø 0.945” (Ø 24mm) X .434” (11mm) h
3 highly flexible, color-coded wires Ø 0.04” (Ø 1.0mm) x 7.0” (18cm)
Optional: Shielded cable Ø 0.083” (Ø 2.1mm) x 1.65’ (0.5m)
Approx. 0.89 ounces (25 grams) (not including cable)
-40°F to +185°F (-40° to +85°C ), optional +257ºF (+125ºC)
-49°F to +194°F (-45° to +90°C ), optional +257ºF (+125ºC) voice: 610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 email: [email protected]
web: www.riekerinc.com
NB3 Series
General Specifications Brochure
Page 2 of 2
Measuring range
Resolution
Max. Non-linearity
NB MODEL SPECIFICATIONS
±10°
< 0.001°
< 0.2% Full Range for ±10° model
< 0.5% Expanded Range for ±20°
Transverse Sensitivity
Response Tme
Power Supply U b
Min ... Max. Supply U bz
NB3
NB3S
Negligible
< 0.3 Sec., Frequency 0-7Hz
< 0.01 Sec., Frequency 0-60Hz
5 Volt regulated
3 ... 6 Volt
Current Consumption U b
=5Volt
Protection Degree
Approx. 1mA
IP65
VALUES FOR ANALOG DC OUTPUT MODEL AT U
BN
=5VOLT
Sensitivity
Temperature drift of sensitivity
Temperature drift of zero
Approx. 15mV/°
< +0.01% /°C
< ± 0.025mV /°C
Zero offset at Ub=5V 2.5 ±0.1 Volt - generally: 0.5Ub ±4%
Output Impedance
10k
Ω
Digital pulse-width modulated output signal - linear to the degree of angle - available upon request.
CABLE WIRING TABLE:
RED
WHITE
3-WIRE (standard)
+5VDC Stable
Output Signal
RED
BLUE
SHIELDED CABLE (optional)
+5VDC Stable
Output Signal
GND (housing) BLUE GND (housing) SHIELD
Figure 1:
Dimensions and Mounting Position (inches [mm])
voice: 610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 email: [email protected]
web: www.riekerinc.com
NG360
General Specifications Brochure
Page 1 of 6
Liquid Capacitive Inclinometer
Sensor with Full 0° to 360° measurement range.
Description
The NG360 is a liquid capacitive based inclinometer used for measuring the tilt angle of any object with respect to gravity within a 0 to 360° range. This inclinometer features an integrated 16-bit single chip microprocessor, which provides for linearity and temperature compensation. The basic sensor consists of four separate sensing elements whose outputs are combined to provide a highly accurate linear output over a complete 360° tilt range. An inclusive EEPROM stores the calibration data and dynamic control functions. The embedded software virtually eliminates total errors by compensating temperature drifts and sets the sensor dynamics for specific customer applications. It provides a very accurate
360° angle output with a RS485 interface. When used along with the SC485B (RS232/RS485) converter the user has the possibility of connecting up to 78 units on the same communication line.
Two computer programs are included along with the
NG360, “Get Angle” and “NG360 Setup”, for viewing the measured angle real time. These programs run on Intel compatible PC’s under MS Windows 95/98. Although the
NG360 can be operated on any half duplex RS485 interface, we recommend the Rieker Electronics interface converter SC485B for problem free operation.
Features
RS485 Output – Bus and Multi-
Sensor Capable
Integrated 16 Bit
Microprocessor
EEPROM Storage of Sensor
Parameters
Windows Based Software
Supporting Bi-Directional
Calibration
Full 360° Angle Sensing
0.01° Resolution
Linearity and Temperature
Compensated
Insensitive to electromagnetic fields
Adjustable zero-position with
360° locking ring
-40°C to +85°C Operating
Temperature Range
Applications
IP65 Protection
Vibration and Shock Resistant
The NG360 inclinometer is suitable for applications requiring the measurement of any angle for further processing on a PC.
Typical areas of application include construction, mining, vehicles, aircraft, ships, surveying equipment, and transportation and conveyor systems.
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
TRANSVERSE SENSITIVI TY
OUTPUT RESPONSE T
SUPPLY VOLTAGE “ON” DELAY TIME
P
OWER SUPPLY
ENVIRONMENTAL PROTEC TION
ELECTRICAL CONNECTIO
N
OPERATING TEMPERATUR E
NG360
General Specifications Brochure
Page 2 of 6
TECHNICAL SPECIFICAT IONS
360º
0.01º
±0.25°
<1% at 45° cross angle
< 0.3 Sec. (<300mSec)
< 50mSec
9V ... 15V approx. 40mA
MECHANICAL CHARACTER ISTICS
30% Glass Filled PBT Plastic
IP65
Flat Vertical Surface with Supplied Mounting Ring
Ø 1.92” (Ø 48.8mm) X 0.85” (21.6mm) h
With Mounting Ring: Ø 2.64” (Ø 67mm) X .85” (21.6mm) h
Ø 0.182” (Ø 4.6mm) Shielded Cable x 1.65’ (0.5m) pigtail leads
Approx. 3.88 ounces (110 grams) (not including mounting ring)
-40°F to +185°F (-40° to +85°C )
-49°F to +194°F (-45° to +90°C )
Figure 1: Dimensions and Mounting Position (inches [mm])
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
Figure 2:
Connection to RS232/RS485 converter (p/n SC485B)
NG360
General Specifications Brochure
Page 3 of 6
Figure 3:
NG360 Sensor Connection to RS485 Bus
•
One sensor on bus can use address
177=hB1 (#00) or individual sensor address
•
110 Ohm terminator internal or external
Single Sensor
•
•
•
•
Maximum of 78 sensors on bus
Maximum cable length is 4km
Do not use address 177 for multiple sensors
No internal terminators, only one at cable end allowed
Multiple Sensors
PC COM PORT TO RS232 / RS485 PROTOCOL
9600
8
None
1
None
110 Ohm
Terminator
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
NG360
General Specifications Brochure
Page 4 of 6
NG360 DATA PROTOCOL
STEP PC TRANSMIT
Address (e.g. B1, B2 or B3…)
ENQ (05h)
15ms Pause (switching from transmit to receive in sensor)
STX (02h)
359,99
Angle in ASCII code
ETB (17h)
Check Sum
(2 Byte ASCII code)
$(24h)
The check sum is a byte by byte
XOR concatenation of the sensor value measured in step 4
(Ex.: 02h XOR 359.99 XOR 17h)
15ms Pause (Switching from receive to transmit in sensor)
ACK (06h)
When check sum is OK
NAK (15h)
When check sum fails
If ACK, then finish
If NAK, return to 3
INSTALLATION AND MOU N
STEP HARDWARE PREPARATION
The NG360 inclinometer will need to be mounted on a vertical mounting plane. The SC485B (RS232/RS485) adapter can be mounted on either a horizontal or vertical mounting plane.
To mount the NG360, prepare a vertical surface with two tapped holes 2.283” apart for the supplied M4 mounting screws. Refer to Figure 1 for the NG360 outline dimensions.
To mount the SC485B adapter, prepare the mounting surface with two tapped holes, tap for either M4 or #8-32 screws. (Screws are not supplied.) Refer to Figure 2 for mounting hole locations. Note all dimensions are in millimeters.
Mount the NG360 to the mounting surface using the supplied mounting ring and M4 mounting screws. Ensure the unit is oriented so that the writing on the label appears horizontal and upright when looking at it straight on. This is the approximate zero position. To zero the unit, loosen the two mounting screws and rotate the sensor within its ring until the output reads zero. Tighten screws when satisfied.
Remove the 4 screws from the SC485B adapter lid to lift the cover.
Route the NG360 cable through the SC485B adapter port and connect the wires as shown in Figure 3. Refer to
Figure 4 for the NG360 and RS485 Bus diagram.
Mount the SC485B adapter with two M4 or #8-32 screws. Replace cover.
Connect the 12VDC adapter plug to the SC485B adapter and the other end to 110VAC wall receptacle.
Connect a 9-pin D-Sub male connector and cable to the PC com port.
STEP SOFTWARE PREPARATION
To display the measurement results and configure the sensor the following programs are used. These programs require a PC running Windows 95/98 or Windows XP. Although the NG360 will operate from any half-duplex RS485 port, we recommend using the SEIKA interface converter SC485B. NG360 programs should be copied to the hard drive before running them!
Load the enclosed software NG360Setup.exe and GetAngle.exe onto a PC.
NG360Setup.exe: This program can be used to change several parameters of the NG360. These parameters can be read, modified and then saved permanently in the NG360 EEPROM. This does not affect any calibration values.
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
NG360
General Specifications Brochure
Page 5 of 6
Run the executable file, NG360Setup.exe to setup system parameters. Parameters that can be reconfigured are data filtering with regards to filter type (Bessel, Period, Butterworth, or Tschebychev), filter order (either no filter, first, or second order), and filter frequency (0.1Hz, 0.5Hz, and 1Hz). The sensor address can also be set and changed if more than one sensor is connected. Refer to Figure 3 for connecting multiple sensors. PC COM port assignment is also accomplished with this program.
The following screen should appear when NG360Setup.exe is executed. The PC COM port shows in the bottom left hand corner and the current sensor address in the bottom right hand corner. If only one sensor is connected, the default address of
177 (hB1) #00 will enable the software to output sensor angles. If multiple units are connected, address 177 (hB1) cannot be used!!! The reason being that all sensors are programmed to respond to the base address of
177 (hB1), in the event of multiple units, a bus conflict would result.
Each individual sensor on the bus will need to have a unique address.
Once a sensor address is selected, the corresponding sensor can be probed for its current parameter settings. Click on “read variables”. This will read the current filter settings and sensor address and display them in the appropriate fields. The variables can be modified by selecting on the drop down menus and then permanently written to the
EEPROM memory by clicking on “write variables”. The variable V064 “delay for serial port” determines the time delay between the individual data bytes transmitted by the sensor. This value can be increased for slower PC interfaces for safer data communication. Default value is 500.
GetAngle.exe: This program displays the angle of one or more NG360, which are connected through a RS232/RS485-
Converter (i.e. p/n SC485B) to the PC. The serial port COM, the sensor address and the display speed (averaging of several measurements) can be adjusted. Additionaly, measurements can be saved to a logfile in regular time-intervals, for further processing i.e. with MS Excel.
Now run the executable file,
GetAngle.exe. This program displays the measured angle for each sensor queried on the RS485 Bus. The following screen should appear.
Set the correct Com port and address. Note address 177 (hB1) #00 can only be used when one sensor is connected.
Clicking on Start will show the sensor output real time. If you want to change the filter parameters go back to the setup program.
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
NG360
General Specifications Brochure
Page 6 of 6
NG360Scan.exe: Use this program to identify every NG360 sensor connected to a serial PC COM port through a
RS232/RS485-Converter. The program scans the whole range of possible NG360 addresses and displays the angle values send by each connected sensor.
Program NG360Scan.exe is also supplied on the disk. This program will determine which sensors are active on the bus and then allow continuous reading of multiple sensors. The following screen will appear when executed.
Select the Com port and click on Scan. The program transmits an inquiry to all 78 possible NG360 addresses and waits for a response. If a sensor answers, the received measured angle is displayed over that sensors address. Click on Start reading to obtain continuous angle measurements from the active sensors. Press Stop reading when finished.
NG360Example.exe: This directory contains an example program for programmers, with complete MS Visual
C++ sourcecode. This open source example program developed using MS
Visual C++ 5.0 provides some information how to develop interface software for the RS232/RS485 converter and the NG360 sensors.
The NG360 sensor is RESET automatically at power on by a defined sequence of operations. The timing for the power on sequence is important for the correct function of the internal microcomputer. The starting edge of the supply voltage should be as short as possible for correct operation.
A supply voltage with a slow rise time or one that bounces can lead to the internal microcomputer program to crash. If this occurs, the sensor will give the impression that it is defective and no longer working. This can normally be fixed by shutting the power off and restarting the process over again making sure the proper input conditions are met. Similar problems can occur if the operating voltage drops below 9V. With the correct input voltage the actual sensor life is unlimited.
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
NGi (4..20mA) Series
General Specifications Brochure
Page 1 of 3
Liquid Capacitive Inclinometer
providing Temperature Compensated
2-Wire Current Loop 4..20mA Output
Description
The NGi Series of inclinometers are liquid capacitive gravity based sensors with integrated sensor and excitation electronics. The thermal drift of the primary sensor is further compensated by an electronic equalization of the temperature.
An integrated highly stable voltage regulator makes it possible to supply the inclinometer from any unregulated supply or battery as low as +8V and up to
+30VDC. The measuring principle assures a linear angle output with 4..20mAs calibrated to equal the measuring range of the sensor. The measuring time constant can be ordered with longer rise times as an option. The power is obtained from the measurement current loop, thereby eliminating the need for a separate power supply and enabling operation with a two wire connection.
Applications
The NGi Series with its current loop output is well suited for industrial use in a noisy environment where high temperature changes occur and non-stable supply voltages are present.
Features
Temperature compensated
4..20mA output
Non regulated +8..+30VDC input
Integrated sensor electronics with 4..20mA excitation
Linear output characteristics
2 wire connection – sensor power obtained from the current loop
High measurement accuracy
Minimal linearity errors
High long-term stability
EMC protected
Vibration and shock insensitive due to non mechanical internal parts
Sensor electronically isolated from housing
Sensor zero mechanically adjusted with mounting ring
Current loop limitation
For additional functionality the SB1i (single axis) and
SB2i (dual axis) inclinometer sensor packages have both zero and gain adjustments. The SB2i is available with ATEX or CSA Certification for Intrinsic Safety.
Typically used in building and bridge construction, mining, radar alignment systems, pitch and roll, agricultural and construction equipment, and process machinery.
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
NGi (4..20mA) Series
General Specifications Brochure
Page 2 of 3
MODEL SPECIFICATIONS
MEASURING RANGE
RESOLUTION
SENSITIVITY
MAX. NON-LINEARITY
TRANSVERSE SENSITIVITY
RESPONSE TME
TEMPERATURE DRIFT OF
SENSITIVITY
TEMPERATURE DRIFT OF ZERO
ZERO OFFSET
POWER SUPPLY
CURRENT CONSUMPTION
HOUSING
ENVIRONMENTAL PROTECTION
MOUNTING
OUTLINE DIMENSIONS
ELECTRICAL CONNECTION
WEIGHT
OPERATING TEMPERATURE
STORAGE TEMPERATURE
BROWN
WHITE
NG2i
±10°
< 0.001°
0.8mA/°
NG3i
±30°
< 0.003°
0.266mA/°
< 1*10
-3
FS
<1% at 45° tilt
< 0.3 Sec. (<300mSec), (optional 1s, 2s, 3s)
NG4i
±80°
< 0.01°
0.1mA/°
<-0.01% /°C
<±10
-3
°/°C
12mA
8..30VDC non-regulated (either polarity)
Approx. 10mA
MECHANICAL CHARACTERISTICS
30% Glass Filled PBT Plastic
IP65
Flat Vertical Surface with Supplied Mounting Ring
Ø 1.92” (Ø 48.8mm) X 0.85” (21.6mm) h
With Mounting Ring: Ø 2.64” (Ø 67mm) X .85” (21.6mm) h
Ø 0.182” (Ø 4.6mm) Cable x 1.65’ (0.5m) (2-wire pigtails leads)
Approx. 3.88 ounces (110 grams) (not including mounting ring)
-40°F to +185°F (-40° to +85°C )
-49°F to +194°F (-45° to +90°C )
CABLE WIRING TABLE:
+VDC input or output
+VDC input or output
Note: wires are interchangeable.
Figure 1:
Block Diagram
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
Figure 2: Wiring Connections
NGi (4..20mA) Series
General Specifications Brochure
Page 3 of 3
Figure 3: Dimensions and Mounting Position (inches [mm])
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
NGU Series
General Specifications Brochure
Page 1 of 2
Single Axis Inclinometer
Analog 0..5VDC Output up to ±80º Range
Description
The NGU Series of inclinometers -
NG2U (±10º), NG3U
(±30º), and NG4U (±80º) - are liquid capacitive gravity based sensors with integrated sensor and excitation electronics. The thermal drift of the primary sensor is further compensated by an electronic equalization of the temperature for uniform accuracy over temperature.
An integrated highly stable voltage regulator makes it possible to supply the inclinometer from any unregulated supply or battery as low as +8V and up to +30VDC. The measuring principle assures a linear angle output with
0..5VDC calibrated to equal the measuring range of the sensor. The measuring time constant can be ordered with longer rise times upon request.
Applications
The NGU Series is well suited for industrial use where high accuracy, long-term stability, and high voltage outputs are desired in environments that experience large temperature changes and where non-stable supply voltages are present.
For additional functionality in an all-weather housing, the
SB1U and SB2G Inclinometer Sensor Packages have both zero and gain adjustments. For dual axis applications refer to the SB2G.
Typically used in building and bridge construction, mining, radar alignment systems, pitch and roll, agricultural/ construction equipment, and process machinery.
Features
Temperature Compensated 0..5V output
Non regulated +8..+30VDC supply input
Integrated sensor electronics with
5VDC excitation
Linear output characteristics
High measurement accuracy
Very low relative linearity errors
Long-term stability
Hysteresis free measuring signal
Not affected by ambient electromagnetic fields
Housing rated IP65
Sensor galvanically isolated from housing
Sensor zero offset mechanically adjusted with mounting ring
EMC Certified
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
NGU Series
General Specifications Brochure
Page 2 of 2
NGU Model Specifications
MEASURING RANGE
RESOLUTION
SENSITIVITY
MAX. NON-LINEARITY
TRANSVERSE SENSITIVITY
RESPONSE TME
TEMPERATURE DRIFT OF
SENSITIVITY
TEMPERATURE DRIFT OF ZERO
ZERO OFFSET
POWER SUPPLY
CURRENT CONSUMPTION
HOUSING
ENVIRONMENTAL PROTECTION
MOUNTING
OUTLINE DIMENSIONS
ELECTRICAL CONNECTION
WEIGHT
OPERATING TEMPERATURE
STORAGE TEMPERATURE
<±10
-3
°/°C
2.5 V
8…30VDC non-regulated
Approx. 10mA
MECHANICAL CHARACTERISTICS
30% Glass Filled PBT Plastic
IP65
Flat Vertical Surface with Supplied Mounting Ring
Ø 1.92” (Ø 48.8mm) X 0.85” (21.6mm) h
With Mounting Ring: Ø 2.64” (Ø 67mm) X .85” (21.6mm) h
Ø 0.182” (Ø 4.6mm) Shielded Cable x 1.65’ (0.5m) pigtail leads
Figure 1: Dimensions and Mounting Position (inches [mm])
NG2U
±10°
< 0.001°
200 mV/º
-40°F to +185°F (-40° to +85°C )
-49°F to +194°F (-45° to +90°C )
NG3U
±30°
< 0.003°
66.67 mV/º
< 1*10
-3
FS
<1% at 45° tilt
< 0.3 Sec. (<300mSec), (optional 1s, 2s, 3s)
<-0.01% /°C
Approx. 3.88 ounces (110 grams) (not including mounting ring)
NG4U
±80°
< 0.01°
25 mV/º
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
NG360
General Specifications Brochure
Page 1 of 6
Liquid Capacitive Inclinometer
Sensor with Full 0° to 360° measurement range.
Description
The NG360 is a liquid capacitive based inclinometer used for measuring the tilt angle of any object with respect to gravity within a 0 to 360° range. This inclinometer features an integrated 16-bit single chip microprocessor, which provides for linearity and temperature compensation. The basic sensor consists of four separate sensing elements whose outputs are combined to provide a highly accurate linear output over a complete 360° tilt range. An inclusive EEPROM stores the calibration data and dynamic control functions. The embedded software virtually eliminates total errors by compensating temperature drifts and sets the sensor dynamics for specific customer applications. It provides a very accurate
360° angle output with a RS485 interface. When used along with the SC485B (RS232/RS485) converter the user has the possibility of connecting up to 78 units on the same communication line.
Two computer programs are included along with the
NG360, “Get Angle” and “NG360 Setup”, for viewing the measured angle real time. These programs run on Intel compatible PC’s under MS Windows 95/98. Although the
NG360 can be operated on any half duplex RS485 interface, we recommend the Rieker Electronics interface converter SC485B for problem free operation.
Features
RS485 Output – Bus and Multi-
Sensor Capable
Integrated 16 Bit
Microprocessor
EEPROM Storage of Sensor
Parameters
Windows Based Software
Supporting Bi-Directional
Calibration
Full 360° Angle Sensing
0.01° Resolution
Linearity and Temperature
Compensated
Insensitive to electromagnetic fields
Adjustable zero-position with
360° locking ring
-40°C to +85°C Operating
Temperature Range
Applications
IP65 Protection
Vibration and Shock Resistant
The NG360 inclinometer is suitable for applications requiring the measurement of any angle for further processing on a PC.
Typical areas of application include construction, mining, vehicles, aircraft, ships, surveying equipment, and transportation and conveyor systems.
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
TRANSVERSE SENSITIVI TY
OUTPUT RESPONSE T
SUPPLY VOLTAGE “ON” DELAY TIME
P
OWER SUPPLY
ENVIRONMENTAL PROTEC TION
ELECTRICAL CONNECTIO
N
OPERATING TEMPERATUR E
NG360
General Specifications Brochure
Page 2 of 6
TECHNICAL SPECIFICAT IONS
360º
0.01º
±0.25°
<1% at 45° cross angle
< 0.3 Sec. (<300mSec)
< 50mSec
9V ... 15V approx. 40mA
MECHANICAL CHARACTER ISTICS
30% Glass Filled PBT Plastic
IP65
Flat Vertical Surface with Supplied Mounting Ring
Ø 1.92” (Ø 48.8mm) X 0.85” (21.6mm) h
With Mounting Ring: Ø 2.64” (Ø 67mm) X .85” (21.6mm) h
Ø 0.182” (Ø 4.6mm) Shielded Cable x 1.65’ (0.5m) pigtail leads
Approx. 3.88 ounces (110 grams) (not including mounting ring)
-40°F to +185°F (-40° to +85°C )
-49°F to +194°F (-45° to +90°C )
Figure 1: Dimensions and Mounting Position (inches [mm])
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
Figure 2:
Connection to RS232/RS485 converter (p/n SC485B)
NG360
General Specifications Brochure
Page 3 of 6
Figure 3:
NG360 Sensor Connection to RS485 Bus
•
One sensor on bus can use address
177=hB1 (#00) or individual sensor address
•
110 Ohm terminator internal or external
Single Sensor
•
•
•
•
Maximum of 78 sensors on bus
Maximum cable length is 4km
Do not use address 177 for multiple sensors
No internal terminators, only one at cable end allowed
Multiple Sensors
PC COM PORT TO RS232 / RS485 PROTOCOL
9600
8
None
1
None
110 Ohm
Terminator
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
NG360
General Specifications Brochure
Page 4 of 6
NG360 DATA PROTOCOL
STEP PC TRANSMIT
Address (e.g. B1, B2 or B3…)
ENQ (05h)
15ms Pause (switching from transmit to receive in sensor)
STX (02h)
359,99
Angle in ASCII code
ETB (17h)
Check Sum
(2 Byte ASCII code)
$(24h)
The check sum is a byte by byte
XOR concatenation of the sensor value measured in step 4
(Ex.: 02h XOR 359.99 XOR 17h)
15ms Pause (Switching from receive to transmit in sensor)
ACK (06h)
When check sum is OK
NAK (15h)
When check sum fails
If ACK, then finish
If NAK, return to 3
INSTALLATION AND MOU N
STEP HARDWARE PREPARATION
The NG360 inclinometer will need to be mounted on a vertical mounting plane. The SC485B (RS232/RS485) adapter can be mounted on either a horizontal or vertical mounting plane.
To mount the NG360, prepare a vertical surface with two tapped holes 2.283” apart for the supplied M4 mounting screws. Refer to Figure 1 for the NG360 outline dimensions.
To mount the SC485B adapter, prepare the mounting surface with two tapped holes, tap for either M4 or #8-32 screws. (Screws are not supplied.) Refer to Figure 2 for mounting hole locations. Note all dimensions are in millimeters.
Mount the NG360 to the mounting surface using the supplied mounting ring and M4 mounting screws. Ensure the unit is oriented so that the writing on the label appears horizontal and upright when looking at it straight on. This is the approximate zero position. To zero the unit, loosen the two mounting screws and rotate the sensor within its ring until the output reads zero. Tighten screws when satisfied.
Remove the 4 screws from the SC485B adapter lid to lift the cover.
Route the NG360 cable through the SC485B adapter port and connect the wires as shown in Figure 3. Refer to
Figure 4 for the NG360 and RS485 Bus diagram.
Mount the SC485B adapter with two M4 or #8-32 screws. Replace cover.
Connect the 12VDC adapter plug to the SC485B adapter and the other end to 110VAC wall receptacle.
Connect a 9-pin D-Sub male connector and cable to the PC com port.
STEP SOFTWARE PREPARATION
To display the measurement results and configure the sensor the following programs are used. These programs require a PC running Windows 95/98 or Windows XP. Although the NG360 will operate from any half-duplex RS485 port, we recommend using the SEIKA interface converter SC485B. NG360 programs should be copied to the hard drive before running them!
Load the enclosed software NG360Setup.exe and GetAngle.exe onto a PC.
NG360Setup.exe: This program can be used to change several parameters of the NG360. These parameters can be read, modified and then saved permanently in the NG360 EEPROM. This does not affect any calibration values.
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
NG360
General Specifications Brochure
Page 5 of 6
Run the executable file, NG360Setup.exe to setup system parameters. Parameters that can be reconfigured are data filtering with regards to filter type (Bessel, Period, Butterworth, or Tschebychev), filter order (either no filter, first, or second order), and filter frequency (0.1Hz, 0.5Hz, and 1Hz). The sensor address can also be set and changed if more than one sensor is connected. Refer to Figure 3 for connecting multiple sensors. PC COM port assignment is also accomplished with this program.
The following screen should appear when NG360Setup.exe is executed. The PC COM port shows in the bottom left hand corner and the current sensor address in the bottom right hand corner. If only one sensor is connected, the default address of
177 (hB1) #00 will enable the software to output sensor angles. If multiple units are connected, address 177 (hB1) cannot be used!!! The reason being that all sensors are programmed to respond to the base address of
177 (hB1), in the event of multiple units, a bus conflict would result.
Each individual sensor on the bus will need to have a unique address.
Once a sensor address is selected, the corresponding sensor can be probed for its current parameter settings. Click on “read variables”. This will read the current filter settings and sensor address and display them in the appropriate fields. The variables can be modified by selecting on the drop down menus and then permanently written to the
EEPROM memory by clicking on “write variables”. The variable V064 “delay for serial port” determines the time delay between the individual data bytes transmitted by the sensor. This value can be increased for slower PC interfaces for safer data communication. Default value is 500.
GetAngle.exe: This program displays the angle of one or more NG360, which are connected through a RS232/RS485-
Converter (i.e. p/n SC485B) to the PC. The serial port COM, the sensor address and the display speed (averaging of several measurements) can be adjusted. Additionaly, measurements can be saved to a logfile in regular time-intervals, for further processing i.e. with MS Excel.
Now run the executable file,
GetAngle.exe. This program displays the measured angle for each sensor queried on the RS485 Bus. The following screen should appear.
Set the correct Com port and address. Note address 177 (hB1) #00 can only be used when one sensor is connected.
Clicking on Start will show the sensor output real time. If you want to change the filter parameters go back to the setup program.
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
NG360
General Specifications Brochure
Page 6 of 6
NG360Scan.exe: Use this program to identify every NG360 sensor connected to a serial PC COM port through a
RS232/RS485-Converter. The program scans the whole range of possible NG360 addresses and displays the angle values send by each connected sensor.
Program NG360Scan.exe is also supplied on the disk. This program will determine which sensors are active on the bus and then allow continuous reading of multiple sensors. The following screen will appear when executed.
Select the Com port and click on Scan. The program transmits an inquiry to all 78 possible NG360 addresses and waits for a response. If a sensor answers, the received measured angle is displayed over that sensors address. Click on Start reading to obtain continuous angle measurements from the active sensors. Press Stop reading when finished.
NG360Example.exe: This directory contains an example program for programmers, with complete MS Visual
C++ sourcecode. This open source example program developed using MS
Visual C++ 5.0 provides some information how to develop interface software for the RS232/RS485 converter and the NG360 sensors.
The NG360 sensor is RESET automatically at power on by a defined sequence of operations. The timing for the power on sequence is important for the correct function of the internal microcomputer. The starting edge of the supply voltage should be as short as possible for correct operation.
A supply voltage with a slow rise time or one that bounces can lead to the internal microcomputer program to crash. If this occurs, the sensor will give the impression that it is defective and no longer working. This can normally be fixed by shutting the power off and restarting the process over again making sure the proper input conditions are met. Similar problems can occur if the operating voltage drops below 9V. With the correct input voltage the actual sensor life is unlimited.
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA a x:::: 610-500-2002 [email protected]
www.riekerinc.com
RAD AV Series
Remote Angle Display for Sound Engineers
Page 1 of 6
The RAD is a portable remote angle display monitoring system for line array alignment, capable of coordinating multiple sensors from one LCD reader.
Photo A: RAD2 (±70º, dual line display with remote sensor boxes - horizontal mount)
Features
•
Hand Held Display Box
•
Rugged Remote Sensors
•
XLR Cord Plug Connectors
•
±70° Measuring Range
•
Non-symmetrical Ranges
Available
•
Angle Displayed in Degrees
•
0.1° LCD Resolution
•
Battery Powered
•
ON/OFF Switch
•
Low Battery Warning
•
Relative Zero or Relative
Difference
•
Minimum/Maximum Angle
Display
•
RS232 Output Optional
Applications
•
Sound System Remote
Alignment
•
Line Array/Speaker
Positioning/Installation
•
Remote Platform Leveling
Description
The (RAD) Remote Angle Display is a precision instrument designed for line array speaker positioning – allowing the sound engineer to quickly establish optimum position of the PA system during installation.
Available as a single line display reading one sensor at a time (RAS2, see Photo B) or a dual line display to measure two sensors at the same time (RAD2, see Photo A), multiple sensors can be used interchangeably with one display box to coordinate multiple stacks.
The dual line RAD allows the installer to view to line arrays simultaneously and is typically sold as a set (ie (1) reader matched to (2) remote sensors).
For maximum flexibility, the single line reader works best for production companies needing to permanently install the remote sensors into various bumpers or rigs, while maintaining a smaller number of readers on the shelf. No more worrying about cross compatibility issues, especially when setting up multiple venues.
The RAD system has two sensor options (see Figures 2 & 3). A typical configuration includes one LCD Reader box with a number of matched sensors; typically 2 or 4 sensors. Both sensor and reader use standard type XLR connectors.
Custom angle range scaling available. For example, a ±70° sensor can be scaled to read +50° to -90°. (Typical V-DOSC configuration).
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RAD AV Series
Remote Angle Display for Sound Engineers
Page 2 of 6
Sensor Measuring Range
Optional Non-Symmetrical
Power Supply (default)
Power Supply (optional)
Remote Sensor Option A
Remote Sensor Option B
Output Units
LCD Display RAD
LCD Display RAS
LCD Resolution
Min / Max Readings - Standard
Relative Zero - Standard
INPUT PARAMETERS
±70°
+50/-90º
9 VDC Battery
Wall adapter (110 or 240VAC) or 8-30VDC Non-regulated
“Black Box” Nema 4 Housing
CS9 IP67 Housing
LCD DISPLAY PARAMETERS
Degrees
Dual Line (see Figure 1A)
Single Line (see Figure 1B)
0.1°
Stored in Volatile Memory
Stored in Volatile Memory
Display LEDs
Open Collector Outputs
Open Collector Current
Switch Function
Switch Trip Delay
Switch Trip Angles
RS232 Output
Baud Rate
Data Bits
Parity
Stop Bits
Display Housing
Mounting Holes
Outline Dimensions
Electrical Connection
Display Box Weight
Operating Temperature
Storage Temperature
Pin 1
Pin 2
Pin 3
OPTIONAL FEATURES
Activated per customer request only* (1 green, 1 yellow, 1 red)
Up to 4 provided
1A each
Normally Open or Normally Closed
0 to 16 seconds
Anywhere within sensor range
OPTIONAL RS232 OUTPUT
Decimal Output
9600
8
None
1
MECHANICAL CHARACTERISTICS - DISPLAY/REMOTE BOX
Die Cast Aluminum – Painted Black
Two M4 x 0.7 or Two #8-32
4.53” x 3.54” x 2.21” (115 x 90 x 56mm)
Female XLR Cord Plug Receptacle (Switchcraft PN D3F)
16 ounces
-20°C to +70°C
-40°C to +85°C
XLR CONNECTING WIRE - DISPLAY/REMOTE BOX
Sensor Ground
Sensor Signal Output
Sensor Supply Voltage
*LED trip angles can only be set within the measuring range of the device and must match the open collector switch outputs if they are chosen.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RAD AV Series
Remote Angle Display for Sound Engineers
Page 3 of 6
FIGURE 1A:
RAD2
LCD Display “Reader” Box
Dimensions (inches [mm])
Dual Line LCD Display Box - battery operated, hand-held two (2) sensor “reader”.
FIGURE 1B: RAS2
LCD Display “Reader” Box
Dimensions (inches [mm])
Single Line LCD Display Box - battery operated, hand-held one (1) sensor “reader”.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RAD AV Series
Remote Angle Display for Sound Engineers
Page 4 of 6
RAD/RAS Button Functions
MIN/MAX Button
The MIN/MAX function provides the smallest and largest angle the device has sensed since it was last reset.
Relative Zero (REL) Button
Standard on all display models: The REL button allows the user to set a new zero position after the RDI is mounted. Press the REL button and release and the display will read REL ON * for 1 sec then 0.00° *. The ( * ) indicates the measurement is not referenced to the true calibrated 0, but a referenced zero. The MIN/MAX angles are now referenced to the new referenced zero. Press the REL button again and the display will read
REL OFF for 1 second then return to the true calibrated zero. The MIN/MAX angles are now again referenced to the true calibrated zero.
Relative Difference (REL) Button
Available for RAD2 only: The REL button is programmed to give the difference between the TOP and BOTTOM sensors. A RAD2 with this feature would display the following: SENSOR 1/SENSOR 2: SENSOR 1 would be placed on top of the speaker array = TOP LINE OF DISPLAY = TOP CONNECTOR on side of box; SENSOR 2 will be placed on the bottom of the speaker array = BOTTOM LINE OF DISPLAY = BOTTOM CONNECTOR on side of box.
REMOTE SENSOR OPTION A: “Black Box”
Description
Tilt angle sensor is mounted and calibrated into a rugged
Nema-4 rated housing, which protects the electronics, provides cable strain relief, and allows either horizontal or vertical mounting.
Connection
(1)
XLR connector is built into box for easy connection.
Mounting
Bolt or screw on for permanent mounting onto the frame or mount with gaff tap, heavy Velcro, or magnet for easy removal for transport and storage.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RAD AV Series
Remote Angle Display for Sound Engineers
Page 5 of 6
FIGURE 2A: Remote Inclinometer Dimensions (inches [mm]) - (Horizontal Mount)
Figure 2B:
Remote Inclinometer Housing Dimensions (inches [mm]) - (Vertical Mount)
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RAD AV Series
Remote Angle Display for Sound Engineers
Page 6 of 6
REMOTE SENSOR OPTION B: “CS9”
Description
This ±70º tilt angle sensor has a rugged potted all-weather Die-Cast metal housing, which protects the electronics in a space saving small footprint.
Connection
XLR connector attached to the robust built-in 3” cable for easy connection.
Mounting
Bolt or screw on for permanent mounting onto the frame. Mounts on a flat vertical surface, like a clock on the wall.
FIGURE 3: CS9 Remote Inclinometer Dimensions (inches [mm])
HOUSING
MOUNTING HOLES
MOUNTING PLANE
OUTLINE DIMENSIONS
ELECTRICAL CONNECTION
WEIGHT
CS9 MECHANICAL CHARACTERISTICS
Die Cast Zinc
Two #6-32
Vertical Surface
Ø1.95” x 1.1” (Ø49.5 x 28mm) See Drawing
1ft. Teflon Cable with 3 pigtail leads
8 ounces (227 grams)
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RDI Series
Rieker Digital Inclinometer Brochure
Page 1 of 5
The RDI Series is a Complete Digital Display of Angle Monitoring and Roll
Over Early Warning System
Description
The RDI provides single or dual axis inclination sensing in a rugged environmentally protected housing. This is a semi-custom unit where all subassemblies are stock but specific functions are customized. A modular design allows the customer to select the measurement range, output type, and temperature compensation that best suits the individual application. Standard input ranges ±10°,
±30° and ±70° are available for both single and dual axis models – these can be scaled to specific ranges
(ie: ±45º) per axis. Special single axis ranges up to
±90° are available. Non-symmetrical (or scalable) ranges (ie: -10° to +90°) are available for applications that only tilt in one direction.
The RDI can be supplied with multiple output configurations: Digital LCD Display, Analog Voltage output, Digital Serial RS232 output, and up to four
(4) Open Collector Switch Outputs providing maximum functionality.
The LCD displays angle in degrees “º”, or optional percent grade “%”, or inch per foot rise with either
0.1 or 0.01 degree resolution. The display models come standard with 3 built in LED’s (1 green, 1 yellow, and 1 red). These can be activated to trip at predefined angles within the specified measurement range - providing the operator a bright visual warning signal - field adjustable trip angle settings optional.
Most all RDI packages are powered by external 8-
30VDC non-regulated input supply (default), with optional 9V battery, 110VAC or 240VAC wall or cigarette lighter adaptor. Interface cables available for remote packages, special connectors available based on request.
Features
Single or Dual Axis Measurement
Custom Input Ranges up to ±90°
LCD Angle in Degrees
LCD Resolution 0.1° or 0.01º
Relative Zero Function
Minimum/Maximum Angle Achieved
Function
Options
LCD Displays Angle in Percent Grade
Analog 0…5VDC Output
RS232 Serial Output
Up to 4 Open Collector Switch Outputs
Adjustable Trip Angle Settings
High Current-Sink Capability
Lamp/Solenoid/Relay Driver
Applications
Slope Warning System
Roll Over Early Warning
Platform Leveling
Pitch and Roll Monitoring
Vehicle Tilt Monitoring
Antenna Positioning
Boom Angle Indicating
Safe Curve Speed Assignment (Ball
Banking)
Sound System Remote Speaker Alignment
Mining/Boring Equipment Leveling
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RDI Series
Rieker Digital Inclinometer Brochure
Page 2 of 5
All RDI LCD display models provide a Relative Zero and a
Minimum/Maximum Angle function as a standard feature, certain options selected may be substituted. The Relative Zero (REL) allows the operator to temporarily zero the digital readout to obtain relative slope changes. The operator will always know when the device is in the REL mode by the (*) symbol that is displayed after the angle. The Minimum/Maximum Angle (MIN/MAX) function provides the smallest and largest angle the device has sensed since the last reset.
RDI Model Types
RD LCD Inclinometer
Examples of LED programming:
For leveling applications - the LED function is set so the green LED turns on when level then switches to yellow or red when out of level;
For indication of safe and unsafe conditions (such as preventing vehicle rollover) - the green light would indicate the vehicle is within the safe operating zone, the yellow light would indicate a warning zone, and the red light would indicate the vehicle is on a slope that exceeds the recommended safe operating zone - giving the operator a bright visual immediate danger signal to return to more even ground.
RDI Optional Features:
RDR LCD Remote Inclinometer
Temperature Compensation can be added depending on the required accuracy over temperature (recommended based on operating temperature). For applications that require remote angle measurement (the sensor unit is mounted separately from the
Display box) we offer remote display inclinometer packages.
0..5VDC analog voltage (0.25…4.25V) output is available - a 12 bit digital to analog converter is used to perform the conversion.
RAD Remote Angle Display
RS232 digital output is presented in decimal format in degrees, percent grade, or inch per foot rise. The output is formatted one reading per line for single axis units and two readings per line for dual axis units. The first reading for a dual axis unit represents channel 1 (typically side to side/roll) and the second reading represents channel 2 (typically front to back/pitch). The dual RDI can also be configured with both channels reading along the same axis for double redundancy.
Non-Display Output Only
Open Collector Switch Outputs (up to 4) can be factory set to switch at a predetermined angle anywhere within the selected measurement range. The switching function can be configured for either Normally Open for out of range indication or Normally Closed for in range indication. The outputs can be used to drive an external buzzer, horn, lamp, solenoid, or relay allowing for audible and/or visual warnings and equipment shut down control. Delay option -
Each switch output can be delayed from 0 to 16 seconds to help eliminate false triggering. Available in both display and non-display models, with a display model the outputs are tied directly to the
LED’s on the front panel and are configured to indicate when switching occurs for the open collector switch outputs.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RDI Series
Rieker Digital Inclinometer Brochure
Page 3 of 5
Measuring Angle Ranges
Measurement Axes
Axis Mounting
Input Power Supply
Current Consumption
INPUT PARAMETERS
Standard: ±10°, ±30°, ±70°
Scalable: Symmetrical ±4° min to ±70° max (single axis up to ±90°)
Scalable: Non-Symmetrical anywhere within full scale of range (ie: -10º to +90º)
Single or Dual
Any Direction
8..30 VDC Non-Regulated, (5VDC Regulated, 9V Battery, 110VAC or 240VAC wall adaptor optional)
Display Version (Without LED): 15mA typical
Display Version (One LED): 35mA typical
Max All Options: 100mA max.
OUTPUT PARAMETERS
< 0.5% FR
Non-Linearity
1
Null Repeatability
Transverse Sensitivity
Response Time
Temperature Drift of Sensitivity
Temperature Drift of Zero
2
2
< 0.05°
<1.0% at 30° Tilt
< 0.3 seconds (300mSec), (slower response times available)
< -0.17%/°C for ±10° models and lower
< -0.12%/°C for models greater than ±10°
< ±0.05 mV/°C for ±10° models and lower
< ±0.025 mV/°C for models greater than ±10°
Temperature Compensated Output
Drift
Output Units
LCD
LCD Resolution
Min / Max Readings
Relative Zero
LED
3
Analog Voltage Output
Voltage Resolution
< ±1.0° (over full operating temperature range)
Degrees, (Percent Grade optional)
LCD BOX PARAMETERS
Single Axis: Single Line Display, Dual Axis: Dual Line Display
Standard: 0.1°, (0.01° optional)
Stored in Volatile Memory
Stored in Volatile Memory
1 green, 1 yellow, 1 red (Activated per customer request)
ANALOG VOLTAGE 0-5V OUTPUT
2.25 ± 2.0 VDC
±10°
<0.01°
±30°
<0.02°
DIGITAL SERIAL RS232 OUTPUT (DECIMAL OUTPUT)
±70°
<0.04°
Baud Rate
Data Bits
Parity
Stop Bits
9600
8
None
1
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RDI Series
Rieker Digital Inclinometer Brochure
Page 4 of 5
Open Collector Outputs
Open Collector Current
Switch Function
Switch Trip Delay
Switch Trip Angles
OPEN COLLECTOR SWITCH OUTPUT
Up to 4 available for activation
1A each
Normally Open: out of range indication, Normally Closed: in range indication
0 to 16 seconds
Factory set anywhere within range, (Adjustable Trip Setting optional)
MECHANICAL CHARACTERISTICS
Housing
Environmental Rating
Mounting Holes
Die Cast Aluminum – Painted Black
Nema 4
Outline Dimensions
Electrical Connection
Two M4 x 0.7 or Two #8-32 (Mounting Feet Optional)
4.54” x 3.54” x 2.27” (115 x 90 x 56mm) See Drawing
15 pin Din (Refer to Wiring); alternative connectors available
Weight
Operating Temperature
16 ounces (not including cable)
LCD Models
-20°C to +70°C, (-4ºF to +158ºF)
Non-Display Models, Storage
-40°C to +85°C, (-40ºF to +185ºF)
Notes: 1. Non-linearity generated by best fit straight line using least squares regression. Output is linear with respect to the input angle directly. 2. Sensor Temperature Drifts apply to Non-Temperature Compensated versions. 3. LED trip angles can only be set within the measuring range of the device and must match the open collector switch outputs if they are selected.
FIGURE 1:
Dimensions (Inches [mm]) and Mounting Position (showing single and dual axis configurations)
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RDI Series
Rieker Digital Inclinometer Brochure
Page 5 of 5
FIGURE 2: DSUB Wiring Connector for Input Power and Selected Outputs
Note: the DSUB15 pin connector is the default electrical connection for the RDI LCD package. The chart below shows all optional outputs, specific models and customer specifications may be different - options may vary from model to model.
Semi-custom models may also include alternate connectors.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RDR Series
Rieker Remote Digital Inclinometer Brochure
Page 1 of 6
The RDR Series is a Complete Remote Display of Angle Monitoring and Roll
Over Early Warning System
Description
The RDR Remote Inclinometer Package is an extension of the RDI Digital Inclinometer series. The package is supplied as a calibrated set featuring an environmentally sealed inclinometer (single or dual axis) and LCD. The RDR has the same features as the RDI including user defined inclination ranges, multiple outputs combinations, and adjustable switch output trip angle settings.
The RDI provides single or dual axis inclination sensing in a rugged environmentally protected housing. This is a semi-custom unit where all subassemblies are stock but specific functions are customized. A modular design allows the customer to select the measurement range, output type, and temperature compensation that best suits the individual application. Standard input ranges ±10°,
±30° and ±70° are available for both single and dual axis models – these can be scaled to specific ranges per axis. Special single axis ranges up to ±100° are available. Non-symmetrical (or scalable) ranges (ie:
-10° to +90°) are available for applications that only tilt in one direction.
The RDI can be supplied with multiple output configurations: Digital LCD Display, Analog Voltage output, Digital Serial RS232 output, and up to four
(4) Open Collector Switch Outputs providing maximum functionality.
The LCD displays angle in degrees with optional percent grade or inch per foot rise. The LCD comes standard with 3 built in LED’s (1 green, 1 yellow, and 1 red). These can be activated to trip at predefined angles within the specified measurement range - providing the operator a bright visual warning signal.
Features
Single or Dual Axis Measurement
Custom Input Ranges up to ±90°
LCD Angle in Degrees
LCD Resolution 0.1° or 0.01º
Relative Zero Function
Minimum/Maximum Angle Achieved
Function
Options
LCD Displays Angle in Percent Grade
Analog 0…5VDC Output
RS232 Serial Output
Up to 4 Open Collector Switch Outputs
Adjustable Trip Angle Settings
High Current-Sink Capability
Lamp/Solenoid/Relay Driver
Applications
Slope Warning System
Roll Over Early Warning
Platform Leveling
Pitch and Roll Monitoring
Vehicle Tilt Monitoring
Antenna Positioning
Boom Angle Indicating
Safe Curve Speed Assignment (Ball
Banking)
Sound System Remote Speaker Alignment
Mining/Boring Equipment Leveling
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RDR Series
Rieker Remote Digital Inclinometer Brochure
Page 2 of 6
All RDI LCD display models provide a Relative Zero and a
Minimum/Maximum Angle function as a standard feature, certain options selected may be substituted. The Relative Zero (REL) allows the operator to temporarily zero the digital readout to obtain relative slope changes. The operator will always know when the device is in the REL mode by the (*) symbol that is displayed after the angle. The Minimum/Maximum Angle (MIN/MAX) function provides the smallest and largest angle the device has sensed since the last reset.
RDI Model Types
RD LCD Inclinometer
Examples of LED programming:
For leveling applications - the LED function is set so the green LED turns on when level then switches to yellow or red when out of level;
For indication of safe and unsafe conditions (such as preventing vehicle rollover) - the green light would indicate the vehicle is within the safe operating zone, the yellow light would indicate a warning zone, and the red light would indicate the vehicle is on a slope that exceeds the recommended safe operating zone - giving the operator a bright visual immediate danger signal to return to more even ground.
RDI Optional Features:
Temperature Compensation can be added depending on the required accuracy over temperature (recommended based on operating temperature). For applications that require remote angle measurement (the sensor unit is mounted separately from the
Display box) we offer remote display inclinometer packages.
0..5VDC analog voltage (0.25…4.25V) output is available - a 12 bit digital to analog converter is used to perform the conversion.
RS232 digital output is presented in decimal format in degrees, percent grade, or inch per foot rise. The output is formatted one reading per line for single axis units and two readings per line for dual axis units. The first reading for a dual axis unit represents channel 1 (typically side to side/roll) and the second reading represents channel 2 (typically front to back/pitch). The dual RDI can also be configured with both channels reading along the same axis for double redundancy.
RDR LCD Remote Inclinometer
RAD Remote Angle Display
Non-Display Output Only
Open Collector Switch Outputs (up to 4) can be factory set to switch at a predetermined angle anywhere within the selected measurement range. The switching function can be configured for either Normally Open for out of range indication or Normally Closed for in range indication. The outputs can be used to drive an external buzzer, horn, lamp, solenoid, or relay allowing for audible and/or visual warnings and equipment shut down control. Delay option - Each switch output can be delayed from 0 to 16 seconds to help eliminate false triggering. Available in both display and nondisplay models, with a display model the outputs are tied directly to the LED’s on the front panel and are configured to indicate when switching occurs for the open collector switch outputs.
Interface cables sold separately, special connectors available upon request.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RDR Series
Rieker Remote Digital Inclinometer Brochure
Page 3 of 6
Measuring Angle Ranges
Measurement Axes
Axis Mounting
Input Power Supply
Current Consumption
INPUT PARAMETERS
Standard: ±10°, ±30°, ±70°
Scalable: Symmetrical ±4° min to ±70° max (single axis up to ±90°)
Scalable: Non-Symmetrical anywhere within full scale of range (ie: -10º to +90º)
Single or Dual
Any Direction
8..30 VDC Non-Regulated, (5VDC Regulated, 9V Battery, 110VAC or 240VAC wall adaptor optional)
Display Version (Without LED): 15mA typical
Display Version (One LED): 35mA typical
Max All Options: 100mA max.
OUTPUT PARAMETERS
< 0.5% FR
Non-Linearity
1
Null Repeatability
Transverse Sensitivity
Response Time
Temperature Drift of Sensitivity
Temperature Drift of Zero
2
2
< 0.05°
<1.0% at 30° Tilt
< 0.3 seconds (300mSec), (slower response times available)
< -0.17%/°C for ±10° models and lower
< -0.12%/°C for models greater than ±10°
< ±0.05 mV/°C for ±10° models and lower
< ±0.025 mV/°C for models greater than ±10°
Temperature Compensated Output
Drift
Output Units
LCD
LCD Resolution
Min / Max Readings
Relative Zero
LED
3
Analog Voltage Output
Voltage Resolution
< ±1.0° (over full operating temperature range)
Degrees, (Percent Grade optional)
LCD BOX PARAMETERS
Single Axis: Single Line Display, Dual Axis: Dual Line Display
Standard: 0.1°, (0.01° optional)
Stored in Volatile Memory
Stored in Volatile Memory
1 green, 1 yellow, 1 red (Activated per customer request)
ANALOG VOLTAGE 0-5V OUTPUT
2.25 ± 2.0 VDC
±10°
<0.01°
±30°
<0.02°
DIGITAL SERIAL RS232 OUTPUT (DECIMAL OUTPUT)
±70°
<0.04°
Baud Rate
Data Bits
Parity
Stop Bits
9600
8
None
1
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RDR Series
Rieker Remote Digital Inclinometer Brochure
Page 4 of 6
Open Collector Outputs
Open Collector Current
Switch Function
Switch Trip Delay
Switch Trip Angles
Housing
OPEN COLLECTOR SWITCH OUTPUT
Up to 4 available for activation
1A each
Normally Open: out of range indication, Normally Closed: in range indication
0 to 16 seconds
Factory set anywhere within range, (Adjustable Trip Setting optional)
MECHANICAL CHARACTERISTICS
LCD
Die Cast Aluminum – Painted Black
Nema 4 – not 100% waterproof
Remote Inclinometer
Die Cast Aluminum – Painted Black
Nema 4 – ALL-Weather
Two M4 x 0.7 or Two #8-32 (Mounting Feet Optional)
4.54” x 3.54” x 2.27” (115 x 90 x 56mm) See Drawing
DSUB15-pin & Amphenol PT0 Type Amphenol PT0 Type
Environmental Rating
Mounting Holes
Outline Dimensions
Electrical Connection
Weight
Operating Temperature
16 ounces (not including mounting feet)
-20°C to +70°C (-4ºF to +158ºF) -40°C to +85°C (-40ºF to +185ºF)
Notes:
1. Non-linearity generated by best fit straight line using least squares regression. Output is linear with respect to the input angle directly.
2. Sensor Temperature Drifts apply to Non-Temperature Compensated versions.
3. LED trip angles can only be set within the measuring range of the device and must match the open collector switch outputs if they are selected.
FIGURE 1: RDI Display Box, Dimensions (Inches [mm]) and Mounting Position
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RDS7-BB-09
Digital Ball Banking Indicator
Page 1 of 3
The RDS7-BB is an electronic ball banking indicator for use in determining safe curve speed.
Features
Angle Range: ±30°
Audible Alarm: adjustable trip settings
Relative Zero: Auto Leveling
Angle Display: Degrees or Percent Grade
Display Resolution: 0.1°
2 Power Options: o
Cigarette Lighter Adaptor Cable/Plug o
8-30VDC input supply ready
Velcro Mounting: Quick Installation and
Easy Removal
Min/Max Reading: freezes the highest
Left and Right corner readings
RS232 Serial Output: connects directly to your PC laptop
Description: The RDS7_BB model was specifically designed for determining safe curve speed of horizontal curves and road signing without the need for a passenger or observer.
The standard digital ball banking unit has a single line LCD display showing angle or slope in degrees. It has a built-in buzzer that is set to alarm at ±10° of angle, which is the limiting angle used by most traffic engineers in the US - however please verify this with your state DOT.
The display has 3 built-in LEDs (GREEN, YELLOW, RED), only the GREEN and RED are activated for this unit. The Green
LED will light when the angle is within the ±10º range, the
Red LED indicates when under or over the limiting angle
(>±10º). Note: this angle can be adjusted if required by your
DOT (either at the factory or by the operator with the adjustable trip angle option).
As you drive through a curve, the microprocessor records the largest positive and negative angles measured since the last reset. The most negative angle is recorded as a left turn and the most positive angle is recorded as a right turn, which would allow the operator to drive an S curve in one sweep.
Once the driver has finished going through a curve, the driver presses the MIN/MAX button once - the left angle is displayed - driver presses the button again - the Right angle is displayed - driver presses the button a third time to reset the display.
Mounting: The RDS7-BB can be mounted on any surface that is within 10 degrees of level. To determine if the surface is within the appropriate level, power up the unit and place it on the desired location. If the unit displays less than 10 degrees then the chosen location is fine. Once the mounting location has been determined, wipe the surface clean with a cleanser such as Windex and then apply one of the supplied strips of Velcro. Apply the remaining strip of Velcro to the bottom of the unit. The RDS7-BB is ready to attach to the vehicle’s surface. With the vehicle on a relatively level surface, power up the unit and look at the digital display to determine if the unit is reading 0 degrees or level. If the selected mounting location is level the unit is ready to begin ball bank operation.
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 n q yy @ www.riekerinc.com
RDS7-BB-09
Digital Ball Banking Indicator
Page 2 of 3
Power Supply: The RDS7-BB has two power options - standard 12 Volt cigarette lighter style cable connection or 8-30VDC non-regulated input via the DSUB15 connector if the vehicle does not have a standard cigarette lighter socket.
Auto Leveling (RELATIVE ZERO): If the unit is not level, but within ±10 degrees, press and release the REL button. The display will read “REL ON” for one second then revert to normal with the unit reading zero. If after pressing the REL button and the display reads “OVER RANGE” the unit is not within ±10 degrees from level. The operator must re-position the unit then repeat auto leveling.
When the unit is in REL mode you will see the (*) symbol displayed indicating that the relative zero
(REL) function is active. Please remember that the unit should be auto leveled using the REL button while the vehicle is on a flat surface. Auto leveling with the REL button must be performed whenever the unit has been powered off.
Operation: Once the RDS7-BB unit has been auto leveled, the operator is ready to go to work. Before driving the stretch of road with the curve that will be evaluated, press the MIN/MAX button slowly three (3) times: The first press will display “LEFT” for one second, then freeze the (-) side reading. The second press will display “RIGHT” for one second, then freeze the (+) side reading. The third press of the
MIN/MAX button will display “RESET”, then immediately go back to normal function.
When in the act of determining safe curve speed, the
MINIMUM reading corresponds to left hand turns and the MAXIMUM corresponds to right hand turns. The
RDS7-BB unit comes factory set to sound an alarm at
±10 degrees, allowing the operator to safely drive through the corner - eyes on the road, not the unit. If the system determines the vehicle has exceeded ±10 degrees, it will sound an alarm, which indicates to the operator to press the MIN/MAX button to display the highest value achieved – providing the necessary information to determine the safe speed for that curve.
RS232 Output: If a laptop computer will be used in conjunction with the RDS7-BB, the appropriate
Rieker power cord will be needed to provide RS232 output. This modified power cord splits to provide a serial port connector as well as the cigarette lighter adaptor.
To install: First, insert the cable’s single-end serial connector into the RDS7-BB’s serial port then attach the computer serial port connector to the laptop’s serial port. Finally, insert the cigarette lighter adaptor end into the cigarette lighter socket of the vehicle – the unit and computer can now be switched on.
When power is supplied to the unit data will begin to flow to the laptop. The data is recorded by a program called HyperTerminal, which is available on PCs running Windows (95, 98, 2000, XP). A single column of numbers will appear on the screen with a (+) or (-) sign to distinguish between a left or right turn. The output provides a continuous stream of readings - one reading per line at approximately 250mSec per reading. The unit is configured for 9600 baud, 8 data bits, no parity, 1 stop bit.
Pressing the MIN/MAX button will stop the flow of data from the RDS7-BB. We recommend you press the MIN/MAX two (2) times in order to display the
“MAX” reading, specifically so that the unit is not outputting data to the computer. When driving and ready to start recording data press the MIN/MAX button one more time to reset the unit and it will resume sending data. Once you have completed the course that you want to record press the MIN/MAX button again to stop the flow of data.
Over Range: The RDS7-BB has a total range of 60 degrees (±30°). When this range is exceeded the display will read “OVER RANGE”. While this will probably not occur during normal use it can occur when mounting the unit or when using the REL button for auto leveling. If you are mounting the unit on a surface that is out of level by more than ±10 degrees the display will read “OVER RANGE”. If this occurs, simply re-position the unit to within ±10 degrees of level.
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 n q yy @ www.riekerinc.com
Figure 1: RDS7-BB Dimensions and Mounting position (inches [mm])
RDS7-BB-09
Digital Ball Banking Indicator
Page 3 of 3
Power Input/Output Cable Assembly p/n: CBL-DB15-6-G
Supplied with your RDS7-BB-09, for input power supply and Digital Serial RS232 Output.
Features:
Two (2) split cables from one (1) DSUB15 male mating connector:
Cable #1: 6 FOOT BELDEN CABLE # 83556 for power input via cigarette lighter adaptor (CLA) plug.
Cable #2: 6 FOOT BELDEN CABLE # 9967 for RS232 output connects to PC via DSUB-9 female serial port connector. NOTE: for laptops with USB ports only, USB/RS232 converter plug connector required, part number A-USB sold separately.
CABLE WIRING TABLE
CONNECTOR
DSUB15
PIN 2
PIN 3
PIN 9
PIN 10
PIN 11
DESCRIPTION
CABLE #1: 6-FT, POWER INPUT
INPUT POWER (+8 TO 30VDC)
POWER/SIGNAL/SWITCH COMMON
CABLE #2: 6-FT, RS232 OUTPUT
RXD
TXD
RS232 COMMON
WIRE
COLOR
WHITE
BLACK
COLOR
WHITE
RED
BLACK
TERMINATION
CLA PLUG
CENTER TAP
OUTER TABS
DSUB-9
PIN 3
PIN 2
PIN 5
6 1 5 0 2 0 0 0
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 n q yy @ www.riekerinc.com
RDSR3-BA-09
Digital Boom Angle Indicator Brochure
Page 1 of 4
Rugged Remote Digital
Boom Angle Inclinometer
FEATURES
Rugged Nema4 Housing
DESCRIPTION
Rieker's Digital Boom Angle Indicator Remote
Inclinometer Package (model RDSR3-BA-09) is an extension of the RDI series of digital inclinometers. The
RDSR3 is supplied as a calibrated set featuring an environmentally sealed measurement inclinometer sensor package and a separate LCD display box
(connected by an interface available in various lengths).
This unit is Temperature Compensated to provide increased accuracy over industry standard operating temperatures.
Specifically configured to comply with safety regulatory agencies (OSHA, ANSI) concerning Boom Angle Indication for Cranes and Derricks (and certain boom lift equipment), the LCD display comes standard with 3 built-in LED’s (1 green, 1 yellow, and 1 red). These can be set to activate at predefined angles within the specified measurement range. An optional audible alarm version (RDSR3-BA-09-A) is also available.
For indication of safe and unsafe conditions - the green light indicates the boom is within the safe operating zone, the yellow light indicates a warning zone, and the red light indicates the boom angle exceeds the recommended safe operating zone - giving the operator a bright visual immediate danger signal.
NOTE: It is the operator’s responsibility to know their particular equipment specifications based on load, height, and length. At no time will Rieker be held liable for damage or injury caused by inappropriate use of this device beyond its intended purpose.
Single Axis Measurement
Operating Temperature -
40..+85ºC
Angle Range -10º..+90º
Backlit LCD
Display Resolution 0.1°
LED Trip Angle Warning Lights
Adjustable Trip Angle Settings
Optional Audible Alarm
Input Supply 8..30VDC Nonregulated
Relative Zero for Level Adjust
Minimum/Maximum: presents last high and low angle achieved
APPLICATIONS
Cranes
Off-Road Forklifts
Material Handlers
Antenna Positioning
INDUSTRIES
Aerospace & Defense
Construction
Energy
Mining
Offshore
Transportation
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
RDSR3-BA-09
Digital Boom Angle Indicator Brochure
Page 2 of 4
RELATIVE ZERO (REL) BUTTON: To temporarily “zero” the RDSR if the remote sensor box is not level but within ±10 degrees - press and release the REL button. The display will read “REL ON” for one second then revert to normal operation with the LCD display reading 0.0º. If after pressing the
REL button and the display reads “OVER RANGE” the remote sensor box is not within ±10 degrees from level. The operator must re-position the remote sensor box then repeat auto leveling. When the unit is in REL mode you will see the (*) symbol displayed indicating that the relative zero (REL) function is active. Please remember that the unit should be auto leveled using the REL button while the equipment is on a flat surface. Once powered down, the RDSR will return to its factory calibrated zero.
MIN/MAX BUTTON: “Minimum/Maximum Angle” function provides the smallest and largest angle the device has sensed since the last reset.
OVER RANGE: The RDSR3-BA-09 has a total range of 100 degrees (-10º/+90º). When this range is exceeded the display will read “OVER RANGE”. The display will return to normal operation by bringing the remote sensor box back within its range.
TECHNICAL SPECIFICATIONS:
Measuring Angle Ranges
Measurement Axes
Power Supply
Current Consumption
Non-Linearity
1
Null Repeatability
Transverse Sensitivity
Response Time
Temperature Drift of Sensitivity
2
Temperature Drift of Zero
2
Temperature Compensation Output
Drift
Output Units
INPUT PARAMETERS
-10º..+90º (full scale of 100º)
Single
8..30VDC Non-Regulated via DSUB mating connector
35mA typical (100mA max.)
OUTPUT PARAMETERS
< 0.5% FR
< 0.05°
<1.0% at 30° Tilt
< 0.3 seconds (300mSec)
< -0.12%/°C
< ±0.025 mV/°C
< ±1.0° (over full operating temperature range of -40/+85ºC)
LCD Display
Display Resolution
Min / Max Readings
Relative Zero
Display LED’s
3
Degrees
DISPLAY PARAMETERS
Single Line Display
0.1°
Stored in Volatile Memory
Stored in Volatile Memory
1 Green, 1 Yellow, 1 Red (Adjustable Trip Angle Settings)
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
RDSR3-BA-09
Digital Boom Angle Indicator Brochure
Page 3 of 4
Housing
Environmental Rating
Display Box Mounting Thru-Holes
Display Box Outline Dimensions
Remote Box with Mounting Feet
Remote Box Outline Dimensions
MECHANICAL CHARACTERISTICS
Die-Cast Aluminum – Painted Black
Nema 4 (please note the LCD is not 100% waterproof)
Two M4 x 0.7 or Two #8-32
4.54” x 3.54” x 2.27” (115 x 90 x 56mm) See Figure 1
Remote Box Only
5.89” x 3.75” x 2.33” (149,6 x 95,3 x 59,19mm) See Figure 2
AMP 745782-4 DSUB15 Female mates to AMP 747908-2 Male
Display Box Electrical Connection
Interface Cable Connection
Weight Per Box
Operating Temperature
PT06E8-4P(SR)-ND (interface cable sold separately)
16 ounces (not including cable)
Display Box
-20°C to +70°C, (-4ºF to +158ºF)
DSUB15 WIRING TABLE - POWER INPUT ONLY
Remote Sensor Box/Storage Temp
-40°C to +85°C, (-40ºF to +185ºF)
PIN NUMBER
PIN 2
FUNCTION
Supply Voltage +8 to +30VDC
PIN 3
Power Common
NOTES
1. Non-linearity generated by best fit straight line using least squares regression. Output is linear with respect to the input angle directly.
2. Sensor Temperature Drifts apply to Non-Temperature Compensated versions.
3. LED trip angles can only be set within the measuring range of the device and must match the open collector switch outputs if they are selected.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
RDSR3-BA-09
Digital Boom Angle Indicator Brochure
Page 4 of 4
FIGURE 1: LCD Display Box Dimensions (inches [mm]) and Mounting Position
FIGURE 2: Remote Inclinometer Box Dimensions (inches [mm]) and Mounting Position
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
RDR Series
Rieker Remote Digital Inclinometer Brochure
Page 5 of 6
FIGURE 2: RDI Remote Inclinometer Box, Dimensions (Inches [mm]) and Mounting Position
FIGURE 3: RDI Display Box with Mounting Feet, Dimensions (Inches [mm]) and Mounting Position
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
RDR Series
Rieker Remote Digital Inclinometer Brochure
Page 6 of 6
FIGURE 4: Remote Box (optional mounting feet) Dimensions (Inches [mm]) & Mounting Position
FIGURE 5: DSUB Wiring Connector for Input Power and Selected Outputs
Note: the DSUB15 pin connector is the default electrical connection for the RDI LCD package. The chart below shows all optional outputs, specific models and customer specifications may be different - options may vary from model to model.
Semi-custom models may also include alternate connectors.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
SB1i
Single Axis Inclinometer Package
Page 1 of 4
The SB1i is a rugged, all-weather sensor package providing a robust 2-wire
4…20mA output.
Features
Die-cast Aluminum housing with sea water resistant finish
Environmental Protection up to IP67
Housing designed for extra stable sensor platform
4…20mA amplifier for 2-wire connection
Temperature compensation beyond the sensors own compensation data
No extra power required
Customer specified angle ranges
Sensor and amplifier are galvanically separated from the housing
Extensive EMC protection
Highly stable sensor supply voltage
Dynamic parameters are programmable
Current-loop with maximum current limitation
High overload resistance
Reverse polarity protected
Low-pass signal filter with optional setting of maximum frequency for suppression of interference frequencies
Description
The SB1i sensor unit is packaged in a solid and compact pressure-cast Aluminum housing with an integrated sensor for single axis inclination or acceleration measurements.
Within the box are 2 sections: An amplifier with a
4…20mA output signal - allowing a 2-wire system; and a separate highly stable power supply for the sensor. The amplifier contains a low-pass filter for upper frequency limitation, with noise suppression filtering and a diode bridge for the unipolar current-loop operation. Both sensor and amplifier are galvanically isolated from the housing - further reducing susceptibility to outside noise. Specific response time constants and maximum current output limitations are additional options.
For a higher degree of accuracy, an NG-type sensor can be integrated into the SB1i box, which considerably reduces temperature drift over the entire temperature range. Add a strong metal PG cable fixing combined with the 2-wire current-loop output the SB1i provides a high-quality system for use under many types of harsh working conditions.
Applications
The SB1i is used where inclination or acceleration measurements need to be combined with a 4…20mA current-loop output: especially where noise and/or distance to source are a concern. Typically used in building and bridge construction, mining, radar alignment systems, pitch and roll, agricultural equipment, and all types of process machinery.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
SB1i
Single Axis Inclinometer Package
Page 2 of 4
Termination/Cable Diameter
Cable Fixing
Measuring Ranges
Protection Degree
Mounting
TECHNICAL DATA
max.: 3 x 1.5 mm
2
M12 x 1.5 cable gland; clamping range 6…7mm
In accordance with the actual sensor
IP65
IP67 with RTV fill
Any direction
Inclinometer Measuring Plane
Accelerometer Measuring Directions
Supply voltage to the box
Minimum loop current
Maximum loop current
Output current loop signal
Adjustable parameters via potentiometers
Max. Load impedance
Operating temperature
N Series: 3 directions of mounting
NG Series: Parallel to the base of housing (default)
B, BDK Series: Place in X, Y, Z co-ordinates to the housing
+10…+30VDC
3mA
22…26mA
4…20mA (12mA as zero point)
Signal-zero (12mA), Span
500 Ohm (at 24 Volt loop supply)
-40…+85°C
OPTIONS
Special measuring ranges, test report, custom wiring
The SB1i Sensor Box is extremely versatile, allowing various configurations with other Rieker sensors. If you have an application that requires alternative specifications, one of our engineers will be happy to discuss how to customize the box for your inclination or acceleration needs.
FIGURE 1:
Dimensions and Mounting Position
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
SB1i
Single Axis Inclinometer Package
Page 3 of 4
FIGURE 2:
Dimensions and Mounting Position
(Shown with N- or NB-type inclinometer sensor or B- or BDK-type Accelerometer)
FIGURE 3:
Measuring Level and Rotation Directions
The above diagrams demonstrate the feasibility of measuring most angles of inclination and directions of acceleration with SB1i sensor packages. With so many choices, we’d be happy to advise you. Contact us today, one of our application experts would be happy to speak with you. A sketch of your application would helpful as necessary.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
FIGURE 4:
Block Diagram and Wiring Connections
SB1i
Single Axis Inclinometer Package
Page 4 of 4
NOTES: Since the supply voltage for the SB1i is obtained from the current-loop and requires a max.
3mA, an input voltage of 9 Volts/min. must be present at the connection block. This is also required in order to guarantee correct operation when the highest loop current of approximately 24mA is used.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
®
SB1S (0-5V)
Single Axis Inclinometer + Switch Output
Page 1 of 3
®
Rugged, all weather housing with integrated sensor & signal amplifier for Analog
0…5 V output.
Includes (2) Open-collector
Switch Outputs.
Description
The SB1S sensor package is for measuring acceleration or inclination along a single axis under harsh operating conditions. Its pressure die-cast Aluminum IP65 rated housing protects an integrated sensor and signal conditioner - providing Analog 0...5V output with a separate, highly stable supply voltage that can be used externally as a reference point.
The signal conditioner also includes an active low pass filter, whole upper cut-off frequency / settling time can be tailored to suit the measurement task, and a noise voltage filter to guarantee the EMC.
Interference signals caused by unwanted ground currents are eliminated by electrically isolating sensor and signal conditioner from the housing.
In addition to the voltage output, the SB1S has two open-collector switch outputs. Two helical trim-potentiometers enable the adjusting of two trigger thresholds within the measuring range, the exceeding of which causes the corresponding output switch to trigger. Optionally at time of order, the state transition can be set to be either off to on or on to off. The switching hysteresis can be adapted to the measuring task.
The SB1S accommodates the N and NG sensor types, the larger NG type has a higher measuring accuracy. A special electronic temperature compensation system significantly reduces the temperature sensitivity of the implemented sensor.
Applications
Suitable for applications requiring precise inclination or acceleration measurements under harsh circumstances, returning of a 0.5 ... 4.5V output signal and the availability of output switches.
Areas of successful implementation include construction, mining, agricultural machinery, transportation and conveyor systems, ships, operation and automation technology as well as general mechanical engineering. The output switches have their application in safety surveillance systems and direct process control.
Features o
Rugged Die-cast Aluminum Housing (IP65) with Saltwater Proof Coating. o
Twist Free 4-point fastening of rigid,
3.2mm thick PCB. o
Integrated Signal Conditioner with 0…5V
Output. o
Temperature Drift Compensation o
8...30 Volt supply voltage. o
Housing and sensitive axis orientations per customer specification. o
Output signal calibrated to customer specifications. o
Sensor and signal conditioner electrically isolated from housing. o
EMC certified. o
Highly stable sensor supply voltage. o
Programmable dynamic response. o
Either connection polarity. o
High overload resistance. o
Low pass filter with optional choice of cut-off frequency for suppression of interference frequencies. o
Two adjustable Open-Collector Switch outputs - switch status indicated via two internal red LED’s.
500----2000
34 Mount Pleasant Road • Aston • PA • 19014 • USA fax: info www.
®
SB1S (0-5V)
Single Axis Inclinometer + Switch Output
Page 2 of 3
®
Internal Wiring Termina
M easuring plane
M easuring plane
M easuring directions
Op erating current ls
(B or BD K
6 x 1.5 mm
2
M12 x 1.5 cable gland, clamping range 6mm - 7.5mm
In accordance with the actual sensor
IP65
Any direction
3 main housing planes
Parallel to the bottom of housing
Place in X, Y, Z coordinates to the housing
+8… +30 Volt
5mA
0.5V…4.5V
2.5Volt
0.05V… 4.95V
( 5+/-0.005) Volt (max.10mA) 20ppm/ºC
100 Ohm any, taking dynamic requirements into account
Switching transistors BCX56
50Volt, 0.3A zero point (2.5V), amplification, lower and upper switch output trigger threshold
Active, 5 th
order, minimal ripple
-40ºC…+85ºC (-40ºF…+185ºF)
Special measuring ranges, custom switching hysteresis, switching state transition: LOW to HIGH or HIGH to LOW, calibration record, silicon encapsulation (RTV for IP67), cable to length available upon request. If you have an application that requires alternative specifications, one of our engineers will be happy to discuss how to customize the box for your inclination or acceleration needs.
500----2000
34 Mount Pleasant Road • Aston • PA • 19014 • USA fax: info www.
®
SB1S (0-5V)
Single Axis Inclinometer + Switch Output
Page 3 of 3
®
Figure 1:
Dimensions and Mounting Position (inches [mm]) - Shown with NG-type inclinometer.
NOTES:
1)
WARNING! Do not short circuit the supply voltage with one of the outputs. The supply voltage (8 to 30VDC) must NOT be incorrectly connected to any output signal.
2)
Diodes protect the open-collector outputs against voltage spikes when switching inductive loads.
3)
Open-collector Switch Output Options:
Version (L): upon exceeding trigger threshold conducting - offers the possibility of connecting both opencollector outputs to one line (wired OR), thereby activating the control signal (e.g. siren) if either of the trigger thresholds is traversed.
Version (N): upon exceeding trigger threshold non-conducting - offers greater security in the activation of an alarm, since a transmission line break or supply voltage failure causes a traversing of the trigger threshold (principle of quiescent current).
500----2000
34 Mount Pleasant Road • Aston • PA • 19014 • USA fax: info www.
®
SB1U (0-5V)
Single Axis Inclinometer Sensor Package
Page 1 of 2
®
The SB1U is a rugged, environmentally sealed sensor package with an integrated inclinometer & signal amplifier for Analog Voltage
0…5 V output.
Features
Specially designed aluminium housing for
extra stable sensor platform
IP65 in sea water resistant coated finish
Integrated 0…5V amplifier
Temperature compensation beyond the
sensors own compensation data
No extra power required
The output signal of the SB1U can be
scaled to customer’s requirements
Sensor and amplifier are galvanically
separated from the housing
Extensive EMC protection
Highly stable sensor supply voltage
Dynamic parameters are programmable
8-30 VDC power supply
High overload resistance
Reverse polarity protected
Low-pass signal filter with optional
setting of maximum frequency for
suppression of interference frequencies
Description
The SB1U sensor box is packaged in a solid and compact pressure-cast aluminum housing with an integrated sensor for single axis inclination or acceleration measurements.
Within the box are 2 sections: An amplifier with a 0…5VDC output signal; and a separate highly stable power supply for the sensor, which can also be used as an external reference Voltage! The amplifier contains a low-pass filter for upper frequency limitation, with noise suppression filtering and a diode bridge that guarantees the electromagnetic compatibility. Both sensor and amplifier are galvanically isolated from the housing - further reducing susceptibility to outside noise. Specific response time constants and maximum current output limitations are additional options.
For a very high degree of accuracy, an NG-type sensor can be integrated into the SB1U box, which considerably reduces temperature drift over the entire temperature range. Add a strong metal PG cable fixing combined with the 2-wire current-loop output the SB1U provides a high-quality system for use under many types of harsh working conditions.
Applications
The SB1U is used where inclination or acceleration measurements need to be combined with a high level DC output. It has been used in building construction, mining, radar systems, bridges, ships, agricultural equipment, and all types of process machinery.
voice: 610-500-2000
34 Mount Pleasant Road • Aston • PA • 19014 • USA
fax: 610-500-2002 email: [email protected]
web: www.riekerinc.com
®
SB1U (0-5V)
Single Axis Inclinometer Sensor Package
Page 2 of 2
®
Technical Data
Termination/Cable diameter max.: Max.: 6 x 1 mm
2
/ Ø 5 ... Ø7 mm
Cable fixing PG7 (Metal with integrated stress relief)
Measuring ranges In accordance with the actual sensor
Protection degree IP65
Mounting Any direction
Sensor measuring plane
(N Series)
Sensor measuring plane
(NG Series)
Accelerometer measuring directions
(B or BD Series)
3 directions of mounting
Parallel to the base of housing
Place in X, Y, Z coordinates to the housing
Supply voltage to the box +8 ... +30 Volt
Operating current 5mA
Maximum range of the output signal +0.05 to +4.95 Volt
Reference initial voltage ( 5+/-0.005) Volt (max.10mA) 20ppm/°C
Output impedance 100Ω
Adjustable parameters via potentiometers
Signal-zero (2.5V), Span
Low-pass filter Active, 5 th
order, minimal ripple
Operating temperature -40 ... +85°C
Options
Special measuring ranges, test report, silicone filled housing, custom wiring
The SB1u Sensor Box is extremely versatile, allowing various configurations with other Rieker sensors. If you have an application that requires alternative specifications, one of our engineers will be happy to discuss how to customize the box for your inclination or acceleration needs.
SB1U Dimensions (in mm) - Shown with NG-type Inclinometer
Caution ! The supply voltage (8 to 30V) must NOT be incorrectly connected to any output signal.
34 Mount Pleasant Road • Aston • PA • 19014 • USA
voice: 610-500-2000 fax: 610-500-2002 email: [email protected]
web: www.riekerinc.com
®
®
SB2i
Dual Axis Inclinometer Sensor Package
Page 1 of 4
The SB2i is a rugged, all-weather sensor package providing two
4…20mA 2-wire outputs.
Features
Die-cast Aluminum housing with sea water resistant finish
Environmental Protection up to
IP67
Housing designed for extra stable sensor platform
2 integrated signal conditioners with 4…20mA, 2-wire outputs
Temperature drift compensation
No separate supply voltage needed
Angle measuring range can be scaled to customer requirements
Compatible with B, BDK, N, and
NB sensor types
Extensive EMC protection
Highly stable sensor supply voltage
Programmable dynamic response
Current-loop with maximum current limitation
High overload resistance
Reverse polarity protected – possibility of 3-wire connection for both measuring loops
Low-pass signal filter with optional setting of maximum frequency for suppression of interference frequencies
Description
The SB2i sensor box is packaged in a solid and compact pressure-cast aluminum housing with two integrated sensors for dual axis inclination or acceleration measurements.
Within the box are 2 amplifier sections, each with
4…20mA output signal, which allows for two separate 2wire systems; and a separate highly stable power supply for the sensor. The amplifiers contain a low-pass filter for upper frequency limitation, with noise suppression filtering and a diode bridge for the unipolar current-loop operation. Both sensor and amplifier are galvanically isolated from the housing - further reducing susceptibility to outside noise. Specific response time constants and maximum current output limitations are additional options.
For a higher degree of accuracy and a considerably reduced temperature drift over the entire operating temperature range, the SB2i box is optimized with special temperature compensation. Add a strong metal PG cable fixing combined with the 2-wire current-loop output the
SB2i provides a high-quality system for use under many types of harsh working conditions.
Applications
The SB2i is used where inclination or acceleration measurements need to be combined with a 4…20mA current-loop output: especially where noise and/or distance to source are a concern. Typically used in building and bridge construction, mining, radar alignment systems, pitch and roll, agricultural equipment, and all types of process machinery.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
®
SB2i
Dual Axis Inclinometer Sensor Package
Page 2 of 4
®
Termination
Cable Fixing
Measuring Ranges
Environmental Protection Rating
Mounting
Inclinometer Measuring Plane
Accelerometer Measuring Directions
Supply Voltage
Minimum Loop Current
TECHNICAL DATA
6 x 1 mm
2
M12 x 1.5 cable gland, clamping range 6mm ... 7.5mm
In accordance with selected sensor
IP65 (with RTV fill IP67)
Any direction
N Series: 3 directions of mounting
B, BD Series: Place in X, Y, Z co-ordinates to the housing
+10 ... +30 VDC non-regulated
2.5mA...3.5mA
Maximum Loop Current
Output Current Loop Signal
22mA…26mA
4...20mA (12mA as zero point)
Adjustable Parameters via Potentiometers
Signal-zero (12mA), Span
Max. Load Impedance
Low Pass Filter
Operating Temperature
500 Ohm (at 24 Volt loop supply)
Active , 3 rd
order, minimal ripple
-40 ... +85°C
OPTIONS
Scaled Angle Measuring Ranges, Calibration Certificate, Slicone RTV Flled Housing (IP67)
The SB2i Sensor Box is extremely versatile, allowing various configurations. If you have an application that requires alternative specifications, one of our engineers will be happy to discuss how to customize the box for your inclination or acceleration needs.
FIGURE 1:
Dimensions ([mm]) and Mounting Position
(Shown with N- or NB-type inclinometer sensor or B- or BD-type Accelerometer)
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
®
®
FIGURE 2:
Mounting Positions and Rotation Directions
SB2i
Dual Axis Inclinometer Sensor Package
Page 3 of 4
FIGURE 3:
Block Diagram
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
®
®
FIGURE 4:
Wiring Connections
SB2i
Dual Axis Inclinometer Sensor Package
Page 4 of 4
NOTES
: Since the supply voltage for the SB2i is obtained from the current-loop and requires a max. 3mA, an input voltage of 9 Volts/min. must be present at the connection block. This is also required in order to guarantee correct operation when the highest loop current of approximately 24mA is used
.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax 610-500-2002 inquiry@riekerinc.com
www.riekerinc.com
SBB Mounting Plate
General Specifications Brochure
Page 1 of 2
SB Sensor Box
Mounting Plates
- Fits SB1i & SB2i models
- Sold separately
- Factory installation available upon request
Description
The stainless steel mounting plates simplify mounting and zero calibration of the SB sensor boxes.
Available in three (3) variations to meet most mounting orientations and space limitations.
Accessories
Screws and tapped bushings included.
Part Number
SBBB1: Square 100x100 mm
SBBS1: Rectangle 129x65mm
SBBW1: Right Angle 129x72x38mm
MATERIAL
WEIGHT (PLATE ONLY)
HARDWARE WEIGHT
DIMENSIONS
Figure 1:
SBBB1 “Square” Dimensions
TECHNICAL SPECIFICATIONS
Stainless Steel
SBBB1 SBBS1 SBBW1
128 grams 102 grams 272 grams approx. 10 grams see dimension drawings
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 support@riekerinc.com
www.riekerinc.com
Figure 2:
SBBS1 “Rectangle” Dimensions
SBB Mounting Plate
General Specifications Brochure
Page 2 of 2
Figure 3:
SBBW1 “L-Bracket” Dimensions
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 support@riekerinc.com
www.riekerinc.com
®
SBG2U (0-5V)
Dual Axis Inclinometer Sensor Package
Page 1 of 2
®
Rugged, Environmentally
Sealed Inclinometer Package with Two Integrated NG
Sensors and Signal Amplifiers,
Providing Temperature
Compensated Dual Axis
Analog 0…5V Output
Features
Rugged pressure die-cast Aluminium housing with saltwater resistant coating
IP65 to IP67 Environmental Protection
2 integrated 0…5V amplifiers
Temperature drift compensation
8…30V unregulated power supply
Angle measuring range can be scaled to customer requirements
Compatible with NG Sensor
Sensor and amplifier are galvanically separated from the housing
Extensive EMC protection
Highly stable sensor supply voltage
Programmable dynamic response
5V reference voltage is available
High overload resistance
Description
The SBG2U sensor box is packaged in a solid and compact pressure-cast aluminum housing with two integrated sensors for dual axis inclination measurement.
Within the box are 2 amplifier sections, each with
0…5V output signal and a separate highly stable power supply for the sensor (this can be used as an external voltage reference). The amplifiers contain a low-pass filter for upper frequency limitation, with noise suppression filtering and a diode bridge guarantee the electromagnetic compatibility. Both sensor and amplifier are galvanically isolated from the housing - further reducing susceptibility to outside noise. Specific response time constants and maximum current output limitations are additional options.
The NG sensors add a very high degree of accuracy and a considerably reduced temperature drift over the whole temperature range. The strong metal PG cable fixing combined with the high voltage signal output makes the SBG2U a high-quality system for use under many types of harsh working conditions.
Low-pass signal filter with optional setting of maximum frequency for suppression of interference frequencies
Applications
The SBG2U is used where a high degree of accuracy for inclination measurements need to be combined with a high level DC voltage output. It has been used in building construction, car manufacturing, mining, radar systems, bridges, ships, agricultural equipment, and all types of process machinery.
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
610-500-2000 www.riekerinc.com
®
SBG2U (0-5V)
Dual Axis Inclinometer Sensor Package
Page 2 of 2
®
Termination/Cable Diameter
Cable Fixing
Measuring Ranges
Protection Degree
Mounting
Sensor Measuring Planes
Supply voltage to the box
Output current
Measuring range of output signal
TECHNICAL DATA max.: 6 x 1 mm
2
/ Ø 5 ... Ø7 mm
M12 x 1.5 cable gland, clamping range 6mm ... 7.5mm
In accordance with selected NG sensor
IP65 (with RTV fill IP67)
Wall mounted, flat vertical surface
Parallel and 90° to the base of the housing
+8 ... +30 Volt
Approx. 12mA
+0.5 to +4.5 Volt
Maximum range of output signal
Reference initial voltage
Output impedance
Output signal zero
Adjustable parameters via potentiometers
Low-pass filter
+0.05 to +4.95 Volt
(5+/-0.005) Volt (max. 10mA)
100
+2.5 Volt
Signal-zero (2.5V), Span
Active, 3 rd
order, minimal ripple
Operating temperature -40 ... +85°C
OPTIONS
Scaled Angle Measuring Ranges, Calibration Certificate, Slicone RTV Flled Housing (IP67)
The SBG2U Sensor Box is extremely versatile, allowing various configurations. If you have an application that requires alternative specifications, one of our engineers will be happy to discuss how to customize the box for your inclination or acceleration needs.
FIGURE 1:
Dimensions ([mm]) and Mounting Position
Attention! Do not short circuit the supply voltage with one of the outputs.
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
®
SBG3i (4-20mA)
Tri-Axis Inclinometer Sensor Package
Page 1 of 2 ®
Rugged, environmentally sealed sensor package with (3) integrated sensors & signal amplifiers for (3) 4…20mA
2-wire outputs.
Features
Rugged pressure die-cast Aluminium housing with saltwater resistant coating
IP65 to IP67 Environmental Protection
Twist free 4-point fastening of rigid,
3.2mm thick base PCB
Three integrated signal conditioners with 4...20mA, 2-wire outputs
No separate supply voltage necessary
All B-, BD- and N- series fit the housing and can be installed in different directions of operation
Output signals calibrated to customer's specifications
Sensors and signal conditioners electrically isolated from housing
Both output channels are electrically isolated from and independent of each other
EMC certified
Internal, highly stable sensor supply voltages
10...30 Volt terminal voltage
Programmable dynamic response
High mechanical overload resistance
Either connection polarity - possibility of 4-wire connection for both measuring loops
Low pass filter with optional choice of cut-off frequency for suppression of interference frequencies
Description
The SBG3i is a pressure die-cast Aluminum sensor housing (IP65) with up to three integrated sensors for measuring acceleration (along three axis for acceleration) and/or inclination (and/or two axis for tilt).
This package also contains three independent signal conditioners, each with a 4...20mA, 2-wire output, and three separate highly stable voltage supply feeding off the corresponding current loop
- one for each sensor. Each signal conditioner includes an active low pass filter, which the upper cut-off frequency / settling time can be adjusted to suit the measurement task, an output stage with current limitation, a noise voltage filter and a diode bridge for unipolar connection to the current loop. Interference signals caused by unwanted ground currents are eliminated by electrically isolating each sensor and signal conditioner from each other and the housing.
A special electronic temperature compensation system can significantly reduce the temperature sensitivity of the implemented sensors. The compact PG cable gland and compact housing size in combination with the 3-wire connection enable the use of this high quality measuring system in harsh operating conditions.
Applications
The SBG3i is suitable for applications requiring precise acceleration or inclination measurements along three axis under harsh circumstances and returning of a 4...20mA output signal each.
Areas of successful implementation include construction, mining, agricultural machinery, transportation and conveyor systems, ships, operation and automation technology as well as general mechanical engineering.
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 inquiries@riekerinc.com
610-500-2000
www.riekerinc.com
®
SBG3i (4-20mA)
Tri-Axis Inclinometer Sensor Package
Page 2 of 2 ®
Termination/Cable Diameter
Cable Fixing
Measuring Ranges
Environmental Protection Rating
Mounting
TECHNICAL DATA
max.: 6 x 1 mm
2
/ Ø 5 ... Ø7 mm
M12 x 1.5 cable gland, clamping range 6mm ... 7.5mm
In accordance with selected sensor
IP65 (with RTV fill IP67)
Any direction
Inclinometer Measuring Plane
Accelerometer Measuring Directions
Supply Voltage
N Series: 3 directions of mounting
B, BD Series: Place in X, Y, Z co-ordinates to the housing
+8 ... +30 VDC non-regulated
Minimum Loop Current
Maximum Loop Current
Output Current Loop Signal
Adjustable Parameters via
Potentiometers
Max. Load Impedance
Operating Temperature
3mA
Approx.24mA
4...20mA (12mA as zero point)
Signal-zero (12mA), Span
500 Ohm (at 24 Volt loop supply)
-40 to +85°C (-40º to +185ºF)
OPTIONS
Scaled Angle Measuring Ranges, Calibration Certificate, Slicone RTV Flled Housing (IP67)
FIGURE 1: Dimensions ([mm]) and Mounting Position
(Shown with N- or NB-type inclinometer sensor or B- or BDK-type Accelerometer) acceleration in direction of the arrow causes a rise of the loop current
2 M4 fastening screws
Housing Height: 58mm
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 inquiries@riekerinc.com
www.riekerinc.com
®
®
SBL1i (4-20mA)
Single Axis Inclinometer Sensor Package
Page 1 of 3
The SBL1i is a rugged, environmentally sealed sensor package with an integrated inclinometer & signal amplifier for a 2-wire Analog Current
4…20mA output
Features
Large, robust pressure die cast aluminum housing (IP65)
Angular adjustable, vibration damped 3point fastening of rigid, 3.2mm thick base PCB
Integrated signal conditioner with
4...20mA, 2-wire output
Temperature drift compensation
No separate supply voltage necessary
Output signal calibrated to customer's specifications
Sensor and signal conditioner electrically isolated from housing
Extensive EMC protection
Highly stable sensor supply voltage
10...30VDC terminal voltage
Loop current limitation
Mechanical overload resistance
Either connection polarity
Low pass filter with optional choice of cut-off frequency for suppression of interference frequencies
Description
The SBL1 sensor box is packaged in a solid die-cast aluminum housing with an integrated sensor for single axis inclination measurements.
Within the box are 2 sections: An amplifier with a 4…20mA current-loop output proportional with the working range of the integrated sensor and a separate highly stable power supply for the sensor, which obtains its power from the
8…30VDC box supply. Both sensor and amplifier are galvanically isolated from the housing - further reducing susceptibility to outside noise. A custom low-pass filter and a suppression filter combine to eliminate interference coming into the system.
The NG-type sensor is integrated into the SBL1 box , which considerably reduces temperature drift over the entire temperature range, for a high degree of accuracy.
Applications
Recommended for use where precise inclination measurements must be taken under harsh environments where an added level of vibration damping is needed. Areas such as construction, mining (especially large open pit mining machinery), agricultural machinery, transportation and conveyor systems, civil engineering (bridge applications), operation and automation technology.
500----2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: [email protected]
www.riekerinc.com
®
®
Termination/Cable D iameter
Inclinometer Measuring Plan e
SBL1i (4-20mA)
Single Axis Inclinometer Sensor Package
Page 2 of 3 max.: 3 x 1.5 mm
2
/ Ø 5 ... Ø7 mm
PG21 (Metal with integrated stress relief)
In accordance with the actual sensor
IP65 (with RTV fill IP67)
Any direction
N Series: 3 directions of mounting
NG Series: Parallel to the base of housing
B, BD Series: Place in X, Y, Z co-ordinates to the housing
+8 ... +30 Volt
3mA
Approx.24mA
4...20mA (12mA as zero point)
Signal-zero (12mA), Span
500 Ohm (at 24 Volt loop supply)
-40 ... +85°C
The SB1i Sensor Box is extremely versatile, allowing various configurations with other Rieker sensors. If you have an application that requires alternative specifications, one of our engineers will be happy to discuss how to customize the box for your inclination or acceleration needs.
FIGURE1: Cable Connections
Since the supply voltage of the SBL1 feeds off the loop current (the SBL1 requires 3mA at the most), a voltage of 9V across the SBL1 terminals must be guaranteed to ensure correct functionality even for the maximum loop current of 24mA (maximum voltage drop across transmission line and load resistor).
500----2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: [email protected]
www.riekerinc.com
®
®
FIGURE2: Mounting Position, Dimensions in [mm]
SBL1i (4-20mA)
Single Axis Inclinometer Sensor Package
Page 3 of 3
500----2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: [email protected]
www.riekerinc.com
®
®
SBL1S
Single Axis/Dual Sensor + Safety Relays
Page 1 of 4
The SBL1S is a Rugged
Inclinometer Package with
Two (2) Independent Sensors for
Uni-Axial Measurement of Tilt, including Two (2) Safety Relays for Threshold Monitoring.
Features
Large, robust pressure die-cast aluminum housing (IP65)
Angular adjustable, vibration damped 3point fastening of rigid, 3.2mm thick base PCB
Two (2) integrated, independent measuring channels (4..20mA currentloop output and 0..5 VDC output), electrically isolated from each other and housing for redundant single axis measurements.
Temperature drift compensation
Channel 1
Signal conditioner with 4...20mA, 2-wire output
No separate supply voltage necessary
Channel 2
Signal conditioner with 0 ... 5V output
12 or 24 Volt supply voltage two separate, individually adjustable safety relay outputs, each with a separate open and close mechanism
Both Channels
Temperature drift compensation
Extensive EMC protection
Either connection polarity
Highly stable sensor supply voltage
Mechanical overload resistance
Low pass filter with optional choice of cut-off frequency for suppression of interference frequencies
Description
In addition to the sensors, the housing contains one signal conditioner with 4...20mA output and one signal conditioner with 0...5V output. These include active low pass filters, whose upper cut-off frequencies / settling times can be adjusted to fit the measuring task, and noise voltage filters to ensure the EMC. Interference signals caused by undefined ground currents are eliminated by electrically isolating sensors and signal conditioners from each other and housing.
The voltage output of the SBL1S has two switch outputs, each with a safety relay. Two helical potentiometers allow the setting of two trigger thresholds within the measuring range, at which the corresponding relay triggers. Each relay output has an independent opening and closing contact. The switching hysteresis can be adapted to the measurement task.
The SBL1S - with a double securing ON/OFF safety control system with both current and voltage outputs combined with special electronic temperature compensation significantly reduces the temperature sensitivity - provides a very stable and strong tilt measuring system for utilization under harsh circumstances.
Applications
Recommended for use where precise inclination measurements must be taken where an added level of vibration damping is needed. Industries include construction, mining, agricultural machinery, transportation and conveyor systems, civil engineering (bridge applications), operation and automation technology.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
®
®
SBL1S
Single Axis/Dual Sensor + Safety Relays
Page 2 of 4
Cable Connection
Cable Diameter
Cable Fixing
Measuring Ranges
Protection Degree
Mounting
Operating Temperature
TECHNICAL DATA
Max.: 15 x 1 mm
Ø12…Ø21,5mm
PG21 (Metal with integrated stress relief)
In accordance with the actual sensor
IP65 (with RTV fill IP67)
In accordance with the actual sensor
-40 ... +85°C
2
(screw connectors)
Inclinometer Measuring Plane
Channel 1
Supply Voltage to Box
Minimum Loop Current
Maximum Loop Current
Output Current Loop Signal
Zero/Amplifier Potentiometer
Max. Load Impedance
Channel 2
Supply Voltage
Supply Current
Nominal Measuring Range
Nominal Zero Output
Maximum Oerating Range
Output Load Impedance
Capacitive Signal Output Load
N or NB Series: 3 directions of mounting
NG Series: Parallel to the base of housing
4...20mA current-loop output
+8 ... +30 Volt
3mA (approximately)
24mA (approximately)
4...20mA (12mA as zero point)
Signal-zero (12mA), Span
500 Ohm (at 24 Volt loop supply)
0..5 VDC voltage and relay outputs
+12 or +24 Volt
Maximum 5mA
+0.5 to +4.5 Volt
+2.5 Volt
+0.05 to +4.96 Volt
100 Ohm
Switching stages
Contacts
Contact Load
Any, considering the high-powered ones
Two SIEMENS safety relays (type SR2A311) – which meet the safety
and technical regulations for usage as safeguard relays an independent open and close contact per relay
250V, 6A
Adjustable Potentiometers
Low-pass Filter
Options
Signal zero (2.5V), amplifier, under- and over-trigger threshold
Active, 4 th
order, minimum ripple
Special measuring ranges, custom switching hysteresis, calibration record
This Sensor Box is extremely versatile, allowing various configurations. If you have an application that requires alternative specifications, one of our engineers will be happy to discuss your needs.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
®
®
FIGURE1:
Mounting Position, Dimensions in [mm]
- Housing Height 100mm
SBL1S
Single Axis/Dual Sensor + Safety Relays
Page 3 of 4
0-5VDC
Output
Sensor
RELAY
RELAY
4-20mA
Output
Sensor
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
®
®
FIGURE2:
Wiring Connections and Set Points
SBL1S
Single Axis/Dual Sensor + Safety Relays
Page 4 of 4
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
®
®
SBS1U
Single Axis Servo Inclinometer Package
Page 1 of 3
Highly sensitive ±1º, environmentally sealed servo inclinometer with ±5 Volt output signal
Description
The SBS1U sensor box is packaged in a solid and compact pressure-cast aluminum housing (IP65) with an integrated sensor for highly sensitive single axis inclination or acceleration measurements.
Within the box are 2 sections: a voltage amplifier with a
±5 Volt output signal and a separate highly stable voltage regulator that supplies power to the sensor.
The amplifier also contains an active low pass filter to suppress interference signals and transient suppression to ensure conformance to EMV regulations. The sensor and the amplifier are galvanically isolated from the housing to avoid interference from signals generated by undefined earth currents. An asymmetric 0 to 5V or a symmetrical
±5V analog voltage signal, each mutually inverse, can be measured on both signal outputs.
The tightly sealed PG metal cable connector and the compact dimensions of the 100% metal sensor housing enable this high quality measurement system to be used under severe operating conditions.
Applications
The SBS1U is recommended for use where extremely precise inclination and acceleration measurements must be taken under difficult conditions and harsh environments.
Typical applications include stability monitoring in the building, machinery, and construction industries as well as inclination monitoring of bridges, dams, towers, tunnels, slopes, and of all structures where there is risk of earthquakes or collapse.
Features
Servo inclinometer with ±1° measurement range and extremely high resolution
±5V output signal for reduced error susceptibility over long signal cables
Rugged IP65 rated pressure-cast aluminum housing with seawater resistant coating
12VDC ± 20% supply voltage
Output signal calibration to customer’s specifications
Sensor and voltage scaling galvanically isolated from housing
EMC Protected
Highly stable internal voltage regulator
Reverse voltage polarity protected
High mechanical shock resistance
Internal low pass filter for
interfering frequency suppression
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
®
SBS1U
Single Axis Servo Inclinometer Package
Page 2 of 3
®
TERMINAL CONNECTIONS
CABLE CONNECTION
MEASUREMENT RANGE
RESOLUTION
PROTECTION LEVEL
INSTALLATION POSITION
OPERATING VOLTAGE OPTIONS
OPERATING CURRENT
STANDARD ASYMMETRIC OUTPUT
VOLTAGE RANGE (GND
→ UA+)
STANDARD ASYMMETRIC OUTPUT
VOLTAGE RANGE (GND
→ UA-)
STANDARD SYMMETRICAL OUTPUT
VOLTAGE RANGE (UA-
→ UA+)
ASYMMETRIC ZERO OUTPUT VOLTAGE
(GND
→ UA+)
TECHNICAL DATA
Max.: 6 x 1.5mm
2
(6 x 16 AWG)
PG9, clamping range 6.5mm - 9.5mm (metal with integrated strain relief)
Max. ±1 degree
0.01 arc seconds = 48µm/km!
IP65
See FIGURE 1
12Volt or 24Volt (±10%)
Max. 100mA
0.5V ... 4.5V
4.5V ... 0.5V
-4V ... 4V
+2.5 VDC
ASYMMETRIC ZERO OUTPUT VOLTAGE
(GND
→ UA-)
SYMMETRIC ZERO OUTPUT VOLTAGE
(UA-
→ UA+)
SIGNAL OUTPUT IMPEDANCE
RECOMMENDED CABLE
CABLE LENGTH TAKING INTO ACCOUNT
VOLTAGE DROP BY THE OPERATING
CURRENT
+2.5 VDC
0 VDC
Approx. 100Ohm
See FIGURE 2
Any (ex. 500m for 12V supply voltage or 1 km for 15V supply voltage when using the recommended or equivalent cable)
CAPACITIVE OUTPUT LOAD CAPACITY
RESISTIVE OUTPUT LOAD CAPACITY
OUTPUT DRIVER
ADJUSTMENT CONTROL
Any
In excess of 100 kOhm
Operational amplifier TLC2274
Amplification
SIGNAL RESPONSE TIME
JUMP OVERRUN FUNCTION
Approx. 2 seconds (98% OF THE EXPECTED VALUE)
PT2 procedure
AMBIENT OPERATING TEMPERATURE -40… +85 °C
MECHANICAL ANGLE ADJUSTMENT RANGE ±2°
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
®
SBS1U
Single Axis Servo Inclinometer Package
Page 3 of 3
®
FIGURE1:
MOUNTING POSITION, DIMENSIONS IN [MM], AND TERMINAL CONNECTIONS
FIGURE2:
CABLE CONNECTIONS
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 [email protected]
www.riekerinc.com
SC485B
General Specifications Brochure
Page 1 of 2
Rugged Interface Converter for Connection of NG360
Sensor with RS485 Interface to RS232 Port of a Computer
Description
The SC485B serves as a very reliable interface between
Rieker sensors with RS485 outputs - such as the NG360 - and computers with RS232 serial ports. Packaged in a solid and compact pressure die-cast Aluminum housing
(IP65) with integrated electronics, this converter has the potential for up to 128 sensors on the RS485 bus.
The interface converter within the housing, consists of a
PCB, a 9-channel DSUB port for the RS232 bus, a 4channel clamp for the RS485 bus, a plug for the external
12V supply voltage, two LED’s for monitoring system operation, the bus voltage level and termination resistances and the interface electronics with voltage level converters and transmission line drivers and receivers.
Applications
The interface converter connects any SEIKA sensor with
RS485 data output interface to the RS232 port of a computer.
Features
Rugged, Pressure Die-cast
Aluminum Housing with
Saltwater Proof Coating
Environmental Protection: IP65
9...15 Volt Supply Voltage
Reverse Polarity Protected
Internal 5 Volt Stabilizing and
Internal Generation of the +/-
RS232 Voltage Levels
Half-duplex RS232 / RS485 bus
RS485 Bus Capacity Up to 128
Participants
9-channel DSUB RS232 Port
4-pole Terminal Block for RS485
Input
Plug Jack for External 12V
Adapter
LED Indicating Bus Activity
INPUT VOLTAGE
CURRENT CONSUMPTION
RS485 WIRE TERMINAL
RS232 CONNECTOR
RS485 BUS
LOAD RESISTOR
RS485 BUS ESD PROTECTION
BUS CAPACITY
DATA TRANSFER RATE
TECHNICAL SPECIFICATIONS
12V ±3VDC
Approx. 30mA + Sensor Current Consumption
4 x 1.5mm
2 max. (4 x 0.059in
2
), 16 AWG max
DSUB 9
Half Duplex
100 Ohm (can be terminated by solder bridge on board)
±15kV (Human Body Model)
128 max.
250kbps max. voice: 610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 email: [email protected]
web: www.riekerinc.com
Figure 1:
Dimensions and Mounting Position [mm]
SC485B
General Specifications Brochure
Page 2 of 2
Figure 2:
Connection to RS232/RS485 converter
BAUD RATE (BIT/SEC)
DATA BITS
PARITY
STOP BIT
PROTOCOL
PC COM PORT TO RS232 / RS485 PROTOCOL
9600
8
None
1
None voice: 610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002 email: [email protected]
web: www.riekerinc.com
SlopeAlert
TM
Tilt Warning System Specification Brochure
Page 1 of 7
DESCRIPTION
SlopeAlert is a reliable, low cost solution for determining inrange and out of range tilt conditions. Originally designed for off-road, in-motion vehicles and equipment that operate in high vibration/shock, rough terrain environments, it is well suited for any application where tilt angle needs to be limited.
Two of the most common applications for this warning device:
1) to help prevent vehicle or equipment rollover on steep slopes; and
2) to aid track vehicles that need protection for over rotation while in motion, especially in rough terrain.
Connected to a lamp, horn, or solenoid relay, this compact single or dual axis unit can indicate both safe and unsafe conditions as well as provide a control signal to help prevent equipment over rotation.
Trip settings are factory set based on customer specification, with trip points indicating side to side and front to back or two points along the same axis. For example first trip at 10º would be the “caution getting close” alert, the second trip at 15º would be the “danger possible roll-over condition” alert).
Rugged Tilt Warning Switch for
Rough Terrain Vehicles &
Equipment in Motion.
FEATURES
Rugged All-Weather Housing
Single or Dual Axis
Open Collector (NPN transistor type)
Relay Option (12 or 24VDC)
Normally Open or Closed Output
Lamp / Buzzer / Solenoid Driver
Single Supply Input (8-30VDC)
Reverse Polarity Protection
Output Short Circuit Protected
High Current-Sink Capability
Inductive Load Protection
-40°C to +75°C Operating
Temperature Range
Shockproof to 500g
Mercury Free
APPLICATIONS
Safe-unsafe Level Alert
Platform Out of Level
Angle Limiting
Roll Over Warning
Process Controls Limit Switch
INDUSTRIES
Aerospace & Defense
Agriculture
Construction
Dump & Tip
Earth Moving
Irrigation
Lawn & Turf Care
Lift & Access
Mining
Offshore
Transportation
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
SlopeAlert
TM
Tilt Warning System Specification Brochure
Page 2 of 7
Standard Trip Point Settings
Non-Standard Trip Point
Power Supply
Current Consumption
INPUT PARAMETERS
±5, ±10, ±15, ±20, ±25, ±30, ±35, ±40, ±45° custom 1º increment settings available (min ±5º/max ±55º and 90º)
8..30 VDC Non-regulated
Optional: 5 VDC Regulated
30 mA typical (60 mA maximum)
OUTPUT PARAMETERS
±1°
±2°
1.0 Amps
Trip Point Tolerance
Actuation Repeatability
Continuous Collector Current
Output Saturation Voltage
Open Collector Switch Output
Supply Voltage
Reverse Battery Voltage
Output Voltage Collector
0.4 V max.
Normally Open for out of range indication
Optional: Normally Closed for in range indication
MAXIMUM RATINGS
35 VDC (35 VDC+ Available upon request)
50 VDC
Emitter (V
CEO
): 50 VDC
Output Transistor Collector
Output Transistor Emitter
Output Collector Current
Operating Temperature
Storage Temperature
Base (V
CBO
): 50 VDC
Base (V
EBO
): 5 VDC
1.5 Amps
-40°.. +75°C (-40º..+167ºF)
-40° ..+85°C (-40º..+185ºF)
MECHANICAL CHARACTERISTICS
Housing
Mounting
Outline Dimensions
Noryl Plastic, Epoxy filled (IP67)
Two #8 screws
2.87” x 2.09” x1.50” (72.6 x 52.8 x 38.1mm) - small single axis model
3.88” x 3.09” x1.50” (88.9 x 78.5 x 38.1mm) - large single or dual axis model
Electrical Connection
24 AWG wires
3 Ounces (Approximately 85 grams) - small single axis model
Weight
12 Ounces (Approximately 340 grams) - large single or dual axis model
OPTIONS
Custom Trip Angle, LED, Buzzer, Relay, Cable Length (see Matrix Chart)
If you have an application that requires alternative specifications, contact one of our application experts who will guide you to the
SlopeAlert best suited for your tilt sensing needs.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
SlopeAlert
TM
Tilt Warning System Specification Brochure
Page 3 of 7
GENERAL NOTES:
1.
The SlopeAlert is a semi-custom sensor, although each model is available with multiple options certain options may not be available simultaneously.
2.
SlopeAlert default Open Collector Output “sinks” current only (NPN Transistor type)
3.
Norly Plastic is a Polyphenylene Oxide-Styrene material, well suited for rugged all-weather environments.
4.
Dual alarm option only available in dual sensor/same axis (RTC) models.
5.
Dual axis units (RTA) with buzzer option - alarm activates when either axis trip setting achieved.
FIGURE 1:
Dimensions for Single Axis SlopeAlert Noryl Enclosure (inches / mm)
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
SlopeAlert
TM
Tilt Warning System Specification Brochure
Page 4 of 7
FIGURE 2: Dimensions for Dual Axis SlopeAlert Enclosure (inches / mm)
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
SlopeAlert
TM
Tilt Warning System Specification Brochure
Page 5 of 7
WIRING NOTES:
1.
CONNECT DIODE TO SUPPLY VOLTAGE WHEN USING INDUCTIVE LOADS.
2.
BASIC UNIT IS SUPPLIED WITH A 4-CONDUCTOR NON-SHIELDED CABLE.
3.
OPTIONS SELECTED WILL DETERMINE IF ADDITIONAL CONDUCTORS SUPPLIED.
FIGURE 3: Basic Wiring Diagram Single Axis
- specific wiring instructions included with each unit depending on options selected
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
SlopeAlert
TM
Tilt Warning System Specification Brochure
Page 6 of 7
FIGURE 4: Basic Wiring Diagram Dual Axis
- specific wiring instructions included with each unit depending on options selected
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
SlopeAlert
TM
Tilt Warning System Specification Brochure
Page 7 of 7
SLOPEALERT PART NUMBER MATRIX
RT C 15 25
AXIS CONFIGURATION
SINGLE AXIS WITH NORYL ENCLOSURE (Default)
DUAL AXIS WITH NORYL ENCLOSURE
DUAL SENSORS SAME AXIS WITH NORYL ENCLOSURE
OPTION
CODE
S
A
C
SIDE TO SIDE SWITCHING ANGLE IN DEGREES
"XX" = 5, 10, 15, 20, 25, 30, 35, 40, 45
Note, custom angles available upon request
FRONT TO BACK SWITCHING ANGLE IN DEGREES
SINGLE AXIS SWITCH (Default)
"XX" = 5, 10, 15, 20, 25, 30, 35, 40, 45
Note, insert higher switch setting if both sensors measure same axis.
Custom angles available upon request.
INPUT POWER
8 TO 30VDC (Default)
5VDC
OUTPUT CONFIGURATION
NORMALLY OPEN (Default)
NORMALLY CLOSED
LED OPTION
NO LED (Default)
ONE RED LED
ONE GREEN LED
ONE YELLOW LED AND ONE RED LED
"XX"
BLANK
"XX"
BLANK
V
BLANK
C
BLANK
G
H
K
BUZZER OPTION
NO BUZZER (Default)
CONSTANT ALARM
PULSING ALARM
PULSING ALARM AND CONSTANT ALARM
INTERNAL LOAD RESISTOR OPTION
NO LOAD
LOAD (Switching ground or power)
INTERNAL RELAY 12 VDC
INTERNAL RELAY 24 VDC
CABLE LENGTH
1 FOOT (0.3 METER - Default)
4 FEET (1.3 METER)
6 FEET (1.9 METER)
10 FEET (3 METER)
20 FEET (6 METER)
30 FEET (9 METER)
BLANK
X
Y
Z
BLANK
P
E*
F*
BLANK
3
4
6
7
8
K Z 6
As shown above the part number RTC1525KZ6 represents a unit with dual sensors measuring the same axis, Noryl enclosure. The first trip setting is ±15°, the larger trip setting is ±25°. The box uses an 8 to 30VDC input, works in a normally open configuration (warns at out of range), has one yellow and one red LED, and one pulse and one constant tone alarm. The yellow LED and pulse tone buzzer activate when ±15° is exceeded; the red LED and constant tone buzzer will activate when
±25° has been exceeded. A cable length of 10 feet has also been requested.
*”E” and “F” RELAY options have the relay wiper internally connected to 12VDC or 24VDC respectively. Consult factory for optional external wiring of relay wiper.
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
XB Series
Sub-Sea + Extreme Conditions Inclinometer Package
Page 1 of 2
Heavy Duty Protection
Against Extreme & Sub
Sea Environments,
Aggressive Media, and
Seawater.
Photo above shows XB with
PG9 Connector.
Photo to left shows XB with
SubConn Underwater Quick
Disconnect Connector.
Features
Heavy-duty stainless steel housing alternative to the Aluminum SB housing
Inclination or acceleration
Single or dual axis
0-5V or 4-20mA outputs up to ±80º measuring range
Seawater resistant - rated V4A
Pressure resistant - 10 bar (1Mpa), 100m
WG
Corrosion resistant
Rigid 4 point attachment of 3.2mm base circuit board
Sensor and sensor electronics are galvanically isolated from housing
Description
The XB is a pressure, seawater, and corrosion resistant stainless steel sensor enclosure that is perfect for extreme environment protection and underwater use.
Available as a single or dual inclinometer package, the XB offers a housing option to the SB
Aluminum housing sensor packages. Sensor specifications and outputs are exactly the same as with the SB sensor packages.
Power input and sensor output would be provided by a cable (optional) that attaches via a liquid tight cable grip fitting (PG9 VA) or an underwater quick disconnect patch cord. The SubConn
Underwater connector adds flexibility to the sealed environment.
Applications
The XB can be used in any extremely rough environment where exact inclination or acceleration measurements must be obtained in aggressive media or below sea level under pressure load.
Typically used for platform leveling or boom angle monitoring of off shore drilling platforms, construction and mining equipment, as well as sea going vessels. It is particularly suited for offshore applications where the use of an underwater patch cord allows sensor connection underwater.
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 [email protected]
www.riekerinc.com
XB Series
Sub-Sea + Extreme Conditions Inclinometer Package
Page 2 of 2
TERMINAL CONNECTION
RANGE, RESOLUTION, OUTPUT
SENSING POSITION
INCLINATION PLANE
ACCELERATION PLANE
ELECTRICAL VALUES
HOUSING
PRESSURE STRENGTH
ENVIRONMENTAL PROTECTION
MOUNTING
INPUT/OUTPUT
CONNECTION
Cable Entry
Patch Cord
WEIGHT
OPERATING TEMPERATURE
STORAGE TEMPERATURE
TECHNICAL DATA
Maximum: 2 x 1.5 mm
2
(2 x 16 AWG)
According to sensor used
Arbitrary
SB1, SB2 (N)
SB1, (NG)
SB1, SB2 (B, BD, BDK)
3 main Housing Directions
Parallel to the Housing Bottom
X, Y, Z-coordinates of Housing
According to the Appropriate SB Sensor Box Requirements
MECHANICAL CHARACTERISTICS
Stainless Steel V4A (seawater resistant)
10 bar (1Mpa), 100 meters below sea level
IP68
Flat Vertical or Horizontal Surface (specified at time of order)
PG9 (V4A steel with integrated strain relief, handles 8-10mm cable diameter)
SubConn® Underwater Plug Connector
4 lbs (1,82 kilograms) (not including cable)
-40°F to +185°F (-40° to +85°C )
-49°F to +194°F (-45° to +90°C )
Figure 1: Dimensions and Mounting Position (inches [mm])
610-500-2000
34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA
fax: 610-500-2002 [email protected]
www.riekerinc.com
Testing & Recalibration Services
Our Testing & Recalibration Services facility is one of the most complete and modern in the industry.
Our engineers and technicians stay abreast of the latest developments in precision measurement and testing - often pioneering advanced testing techniques.
To assist you in establishing and maintaining a routine calibration program, we can automatically notify you when the next certification is due.
Call us today at
610-500-2000
to find out more.
POSITION SOLUTIONS PROVIDER
Industries:
Aerospace & Defense
Agricultural
Automotive
Aviation
Civil Engineering
Construction
Drilling & Boring
Fire & Rescue
Government
Industrial Automation
Lift & Access
Marine
Military
Mining
Offshore
Railroad
RV & Coach
Sound-Reinforcement
Trailer & Chassis
Transportation
Utility
Applications:
Antenna Positioning
Auto-Leveling Systems
Ball Banking
Boom Angle Indication
Grade Control
Line-Array Alignment
Pitch & Roll
Platform Leveling
Process Controls
Rollover Warning
610-500-2000
RIEKER INC • 34 MOUNT PLEASANT ROAD • ASTON • PA • 19014 • USA fax: 610-500-2002
www.riekerinc.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 COVER
- 2 Introductory Page
- 14 Accelerometers
- 14 B Series Static type
- 16 BDK Series Dynamic type
- 98 SBG3i 3-Axis package
- 3 Ball Bank Indicators
- 3 1023W1 traditional ball in tube type
- 72 RDS7-BB digital ball bank type
- 19 CARS Automated Service
- 9 Boom Angle Indication
- 75 Digital Remote LCD Boom Angle Indicators
- 9 Mechanical Boom Angle Indicators
- 12 Bulls-Eye Bubble Levels, Precision Circular
- 32 Electronic Inclinometers
- 32 4..20mA Output (analog)
- 25 H4360 360º, Single Axis
- 32 H6 Dual Axis Programmable
- 46 NGi Single Axis
- 81 SB1i Single Axis
- 90 SB2i Dual Axis
- 119 XBi Stainless Steel Sub Sea
- 21 0..5VDC Output (analog)
- 21 H4A Single Axis
- 29 H5A Single axis (+0-10VDC)
- 38 NB3 fast response sensor
- 49 NGU Single Axis
- 96 SBG2U Dual Axis
- 29 0..10VDC Output (analog)
- 29 H5A Single axis
- 21 RS232 Output (digital)
- 21 H4S Single Axis
- 29 H5S Single axis
- 63 RDI Digital Inclinometers
- 32 RS485 Output (digital)
- 32 H6 ±180º dual axis
- 51 NG360 360º single axis
- 32 CAN Ready
- 107 Servo Inclinometer
- 32 Flex Series Programmable Inclinometers
- 32 H6 ±180º Dual Axis 4..20mA, RS485, CAN
- 11 Gradiometers
- 11 5012P Gradiometer, mechanical
- 7 2064EGM Gradiometer, mechanical
- 3 Mechanical Inclinometers (Tilt Meters)
- 3 1000 Series 10º, 20º, Metal Housing
- 5 2000 Series 26º, 45º, 60º Plastic Housing
- 7 2100 Series Customizable Clinometers
- 63 RDI Digital LCD Display Inclinometers
- 68 Digital Remote LCD (RDR)
- 57 Remote Angle Display (RAD)
- 112 Tilt Switches & Relays
- 112 SlopeAlert Tilt Warning
- 63 RDI Digital Inclinometers
- 85 SB1S 0..5VDC, Open Collector
- 103 SBL1S Safety Relays
- 94 Accessories
- 18 BS24 Mounting Cube (B, BDK, N, NB only)
- 110 RS485 to RS232 Converter
- 94 SBB Mounting Plates (SB types only)
- 121 BACK COVER, contact information