Compuware 17.02 Enterprise Common Components Installation and Configuration Guide
Pubblicità
Pubblicità
Enterprise Common Components
Installation and Configuration Guide
Release 17.02
2
Enterprise Common Components Installation and Configuration Guide
Please direct questions about Enterprise Common Components or comments on this document to:
Compuware Customer Support https://go.compuware.com/
This document and the product referenced in it are subject to the following legends:
Copyright 2017 Compuware Corporation. All rights reserved. Unpublished rights reserved under the Copyright
Laws of the United States.
U.S. GOVERNMENT RIGHTS-Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in Compuware Corporation license agreement and as provided in DFARS 227.7202-1(a) and 227.7202-
3(a) (1995), DFARS 252.227-7013(c)(1)(ii) (OCT 1988), FAR 12.212(a) (1995), FAR 52.227-19, or FAR 52.227-14
(ALT III), as applicable. Compuware Corporation.
This product contains confidential information and trade secrets of Compuware Corporation. Use, disclosure, or reproduction is prohibited without the prior express written permission of Compuware Corporation. Access is limited to authorized users. Use of this product is subject to the terms and conditions of the user’s License
Agreement with Compuware Corporation.
Abend-AID, Abend-AID Fault Analytics, Abend-AID for WebSphere MQ, Abend-AID for CICS, CICS Abend-
AID/FX, Xpediter, DevEnterprise, File-AID for DB2, STROBE, UNIFACE, Compuware Shared Services, CSS,
Compuware Viewing Facility, Compuware/VF, Enterprise Common Components, and ECC are trademarks or registered trademarks of Compuware Corporation.
IBM, CICS, DB2, z/OS and MVS/ESA are trademarks or registered trademarks of International Business Machines
Corp.
Adobe
®
Reader
®
is a trademark of Adobe Systems Incorporated in the United States and/or other countries.
All other company and product names are trademarks or registered trademarks of their respective owners.
Doc. JUL2017
September 29, 2017
Table of Contents
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ECC Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Planning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Prerequisites
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Milestone 1: Install ECC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Milestone 2: Configuration Preparation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Milestone 3: Configuration for an Upgrade
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Milestone 4: Configure LMS for a New Install
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3
4
Enterprise Common Components Installation and Configuration Guide
Milestone 5: Configure HCI for a New Install
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Milestone 6: Configure CMSC for a New Install
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Milestone 7: Configure CSS for a New Install
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Milestone 8: Configure Topaz Workbench Integration
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Milestone 9: Deployment
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Milestone 10: Migration Utility
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Checklist of Milestones and Tasks
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Introduction
This manual provides information about how to install, customize, and maintain Enterprise
Common Components.
Intended Audience
This manual is intended for Enterprise Common Components installers and z/OS system programmers.
System Environment
See the Enterprise Common Components Release Notes for the most current system environment information.
Related Publications
An RFN order email also includes a copy of the Compuware Installer Mainframe Products SMP/E Installation
Guide, which should be used to perform the installation of Enterprise Common Components.
Preparation for installation and post-installation configuration should be done according to this
Guide.
The documents in the following list are available on Compuware FrontLine
(
https://go.compuware.com
).
• Compuware Installer
• Enterprise Common Components Advanced Configuration Guide
• Enterprise Common Components Messages and Codes
• Compuware Shared Services User/Reference Guide
• Enterprise Common Components Release Notes
Documentation Availability
Online Documentation
The Enterprise Common Components product installation package does not include the product documentation. Access the Enterprise Common Components documentation from the Compuware
FrontLine Customer Solutions website at https://go.compuware.com in the following electronic formats:
• Release Notes in HTML format
• Product manuals in PDF format
• Adobe PDF index file (PDX file)
• Product manuals in HTML format.
The product documentation is available for viewing or downloading:
Intro
5
6
Enterprise Common Components Installation and Configuration Guide
• View PDF files with the free Adobe Reader, available at http://www.adobe.com.
• View HTML files with any standard web browser.
Icons
The alerts found in this guide include:
A note or tip providing additional information.
Information important to remember.
If a particular milestone or task doesn’t apply to your site—or your site is not licensed for a particular option—you can skip ahead to the next milestone or task by clicking the icon.
Caution. Failure to follow these instructions can cause serious problems.
Indicates which skill set is most likely needed to perform the following task(s).
Customer Support
Compuware provides a variety of support resources to make it easy for you to find the information you need.
Compuware FrontLine Customer Solutions Website
You can access online information for Compuware products via our FrontLine Customer Solutions website at https://go.compuware.com.
Compuware FrontLine provides access to critical information about your Compuware products. You can review frequently asked questions, read or download documentation, access product fixes, or email your questions or comments. The first time you access Compuware FrontLine, you are required to register and obtain a password. Registration is free.
Contacting Customer Solutions
Phone
• USA and Canada: 1-800-538-7822 or 1-313-227-5444.
• All other countries: Contact your local Compuware office. Contact information is available at
https://go.compuware.com
.
Web
You can report issues via the Quick Link Create & View Support Cases on the Compuware FrontLine home page.
Note: Please report all high-priority issues by telephone.
Introduction
Compuware Customer Solutions
Compuware Corporation
One Campus Martius
Detroit, MI 48226-5099
Corporate Website
To access Compuware’s site on the Web, go to http://www.compuware.com .
The Compuware site provides a variety of product and support information.
7
Information for Customer Support
If problems arise, please check your manual for assistance. If problems persist, please obtain the following information before calling Compuware for assistance. This information will help determine the exact cause of the problem as quickly as possible.
1. Identify the release number of Compuware product(s) in use.
2. Identify the operating system.
3. Identify the release of CICS Transaction Server that is being used.
4. If an abend occurs, note the displacement and the module in which it occurs. If possible, obtain a copy of the system dump.
5. Note the sequence of steps (including all commands issued) that resulted in the problem. Also note any variable data types and programming languages involved.
6. To receive product fixes electronically, be ready to provide your email address.
8
Enterprise Common Components Installation and Configuration Guide
ECC Overview
Enterprise Common Components (ECC) is a product delivered as a single install image for the following Compuware facilities:
• Compuware Mainframe Services Controller (CMSC)
• License Management System (LMS)
• Host Communications Interface (HCI)
• Compuware Shared Services (CSS)
• Base Services
All components of ECC are installed together using the single install image. ECC consists of a single
FMID (MLCXnnn) for all components, operating from one authorized load library (SLCXAUTH) and one non-authorized load library (SLCXLOAD). CMSC, LMS, HCI, CSS, and Base Services are all on the same release level.
Compuware recommends that you activate and configure all the ECC components at the same time to avoid compatibility issues between different release levels. Which components of ECC you need to activate and configure depends on which Compuware products are licensed by your organization.
ECC is installed using SMP/E, facilitated by the Compuware Installer. Each ECC component can be configured individually, depending on your site’s requirements.
Integration of ECC with Other Compuware Products
Compuware Mainframe Services Controller (CMSC) is required for any Compuware mainframe product, release 17.02 or higher, as those products use Compuware’s Common PARMLIB.
License Management System (LMS) is required for any Compuware mainframe product, in order to verify that the corresponding License Certificate exists, enabling use of the product.
Host Communication Interface (HCI) is required to facilitate communications between a distributed Compuware product (for example, Topaz Workbench) and a mainframe Compuware product(s).
Compuware Shared Services (CSS) is required for sharing compiled program information for
Compuware products (for example, Xpediter).
Base Services is required to support CMSC and Abend-AID.
0
9
10
Product Architecture
Enterprise Common Components Installation and Configuration Guide
Compuware Mainframe Services Controller (CMSC) Overview
The CMSC address space is a centralized facility providing license management and common parameter library services. The CMSC can also automatically start HCI address spaces. HCI address spaces started by the CMSC will automatically restart in the event of a failure.
As the service provider for the new Compuware’s Common Parameter Library feature (Common
PARMLIB), the CMSC reads the user’s parameter libraries, stores parameters for Compuware products in memory, and initializes the parameter retrieval service used by Compuware products. Operator commands are provided to refresh the parameters in memory in the event of a change to one or more of the parameter library members.
ECC enables Compuware mainframe products to use PARMLIBs for storing configuration data.
Instructions are provided to guide you through any necessary migration to using PARMLIBs.
Compuware’s mainframe products, with a release of 17.02 or greater, use a Common PARMLIB for specifying configuration and customization parameter values, serviced through the CMSC address space. Parameter values are stored in a PDS or concatenation of PDS libraries. The PARMLIB members are human readable and editable, allowing administrators to view or change values using an operator command. z/OS System Symbolics are supported by Common PARMLIB members, which can be helpful in simplifying, for example, multiple LPAR deployments.
Common PARMLIB to all Compuware mainframe products release 17.02 and higher, similar product information can be expressed to more than one Compuware product. For example, Strobe information can be defined for both Strobe and another product, like HCI.
Users can also specify different PARMLIB members for different invocations of individual products.
For example: HCInn where the nn identifies the PARMLIB member is to be used.
For further information regarding the Common Parameter Library, review “Enterprise Common
Components Advanced Configuration Guide”.
ECC Overview
11
License Management System (LMS) Overview
LMS enables you to manage access to all the Compuware products used by your organization. LMS consists of several small components which allow you to establish, maintain, diagnose, and upgrade your access to the Compuware products licensed by your enterprise:
• An ISPF License Administration Utility application
• A runtime environment
• A program interface to the runtime environment employed by Compuware products
LMS License Certificates are English-like text files that are sent to you electronically. You will receive a License Certificate for each new product release under LMS. You can centrally manage all your organization’s License Certificates in a single License File that can then be distributed to various sites.
LMS now executes in the CMSC address space.
Host Communications Interface (HCI) Overview
The HCI is a facility that provides connectivity between mainframe-based programmer productivity software and peer-node software running on other platforms in a network. The HCI also serves as a server activation facility that is responsible for starting and monitoring application programs that are using the communications facilities.
The HCI now uses a single simplified parameter member that supports all functionality in the HCI for any Compuware product including Topaz Workbench, DevEnterprise, and Strobe.
Compuware Shared Services (CSS) Overview
CSS is an enterprise-wide tool for sharing compiled program information. CSS is used by many
Compuware products spanning the application debugging, application performance management, and fault management product lines.
CSS provides storage, retrieval, and maintenance for Abend-AID reports, source listings, and transaction dump information in datasets called DDIO files. Shared directories and their attached databases are also types of DDIO files being used, which provide improved efficiency in maintaining information and activity within these files. CSS also provides language processing support for
COBOL, PL/I, Assembler, and C.
Base Services Overview
Base Services is an application framework providing batch, server, subsystem and presentation components. Functions include dynamic allocation, storage management, transaction scheduling, message formatting, operator command routing, recovery and termination management, and screen, menu and message presentation in ISPF, VTAM, CICS and web browser environments. This framework is used by CMSC, Abend-AID and Abend-AID for CICS.
12
Enterprise Common Components Installation and Configuration Guide
13
Planning
This section provides information related to planning an installation or update to Enterprise
Common Components (ECC).
Steps Involved
1. Order ECC and its companion products, including the latest maintenance, via Compuware’s
Product Ordering web page or by calling Compuware’s License Management at 800-538-7822. Before
ordering, you should understand the system requirements and prerequisites. See “Prerequisites”.
2. Install ECC per the instructions provided in the order confirmation email. See
3. Follow the instructions in this guide to configure and deploy ECC. See
before beginning an configuration steps. Also, for configuration information for an upgrade see
“Milestone 3: Configuration for an Upgrade”.
Milestones and Roles
identifies the role or skill set required for each of those milestones. Knowing the persons involved, with some proper planning, you may be able to have certain milestones or tasks performed at the same time.
Table 1.
People Required for Each Milestone.
Milestone
“Milestone 3: Configuration for an Upgrade”
“Milestone 4: Configure LMS for a New Install”
“Milestone 5: Configure HCI for a
“Milestone 6: Configure CMSC for a New Install”
“Milestone 7: Configure CSS for a
New
Install
●
●
●
●
●
●
●
●
Upgrade
●
z/OS
Systems
Programmer
●
z/OS Security
Administrator
● ● ●
●
●
●
●
●
●
●
●
0
14
Enterprise Common Components Installation and Configuration Guide
Checklist of Milestones and Tasks
Consult the
checklist of the milestones and tasks involved in the install. For convenience, you may
want to print this page and check off the milestones and tasks to mark your progress through the install.
Preparation
The following are considerations to take notice of, and to remember, when doing the customization of ECC or one of its components.
ECC Considerations
OMVS Segments
• The CMSC and HCI started tasks require that an OMVS segment be defined for the user ID associated with each of these started tasks to perform various TCP/IP services.
TCP/IP Security
• The CMSC and HCI started tasks require access to the TCP/IP stack through which they communicate. This requires that these started tasks have READ authority to the
EZB.STACKACCESS resource class.
HCI Considerations
TCP/IP
To avoid any unpredictable connection issues, make sure all current IBM maintenance is applied to
TCP/IP.
Before you install the HCI on a z/OS LPAR, you must be able to run TCP/IP traffic from the workstation to that LPAR or host.
Prerequisites
System Requirements
Hardware Platforms for Mainframe Systems
• zEC12, zBC12, z13
• z196, z114
• z10-EC/BC
• z9-EC/BC
• z900, z990
• z800, z890
IBM Specialty Processors Enablement
• Language processor is zIIP
Operating Systems
• IBM z/OS V2.1, 2.2
• IBM ISPF for the supported z/OS releases
Languages
• IBM Enterprise COBOL for z/OS V3.4, 4.2, 5.1, 5.1.1, 5.2, 5.3, 6.1
• IBM Enterprise PL/I for z/OS V3.9, 4.2, 4.3, 4.4, 4.5, 5.1
• IBM High Level Assembler for z/OS, z/VM, and z/VSE V1.6
• IBM z/OS XL C/C++ for the supported z/OS releases
Co-requisites – Compuware Products and Components
• Abend-AID 12.3, 12.4, 16.05, 17.02
• Abend-AID for CICS 12.3, 12.4, 16.05, 17.02
• Compuware Program Analyzer 5.3, 16.05
• Compuware Workbench 4.0, 5.0
• DevEnterprise 16.05
• File-AID 10.1, 10.2, 16.03, 17.02
• Strobe 5.1, 5.2, 16.03, 17.02
• Xpediter/CICS 9.3, 9.4, 16.05, 17.02
• Xpediter/TSO 9.3, 9.4, 16.05, 17.02
15
0
16
Enterprise Common Components Installation and Configuration Guide
• Topaz Workbench 16.03, 17.02
Notes:
1. All 17.02 Compuware mainframe products require a minimum of ECC 17.02, including all maintenance.
2. Pre-16.05 releases of the ECC components (which include LMS 4.0, HCI 3.0, and CSS 9.0) will not be supported by any Compuware mainframe products release 17.02 or greater.
3. Abend-AID 16.05 or newer, Compuware Program Analyzer 16.05 or newer, and DevEnterprise
16.05 or newer require ECC 16.05 or newer.
4. ECC 16.05 or newer cannot be in the same Target and Distribution zones as ECC 3.3 and prior releases, Abend-AID 12.4 and prior releases, Compuware Program Analyzer 5.3, or DevEnterprise
5.3 and prior releases. However, they can coexist in the same Global zone.
17
Milestone 1: Install ECC
ECC is a mainframe product delivered using Receive From Network (RFN) and is packaged for installation using System Modification Program Extended (SMP/E). RFN and SMP/E are IBM methods developed to transfer and install software products in the z/OS environment.
This milestone provides information and instructions for transferring the Compuware product to your mainframe and completing the SMP/E process to install the product into Global, target, and distribution zones, in preparation for configuring the product for your site’s use.
Role involved: z/OS Systems Programmer
Be aware that Abend-AID, Xpediter/TSO, Xpediter/CICS, and Strobe make extensive use of ECC. ECC releases are downward compatible but not upward compatible. You must ensure that the products are
NOT pointing to a release of ECC that is lower than the release of ECC used during the step which loads the listing into the DDIO (whether it is part of the compile process or a standalone task). We suggest you review your product configurations to guarantee they are running with the desired release of ECC.
Task 1.1 RFN and SMP/E Install
1. Follow the instructions in the Compuware Installer Mainframe Products SMP/E Installation Guide to transfer and install ECC.
2. Once completed, return to this document to configure and deploy ECC.
ECC 16.05 or newer cannot be in the same Target and Distribution zones as ECC 3.3 and prior releases,
Abend-AID 12.4 and prior releases, Compuware Program Analyzer 5.3, or DevEnterprise 5.3 and prior releases. However, they can co-exist in the same Global zone.
To keep your ECC software current, download and apply the quarterly cumulative maintenance file delivered through Compuware’s FrontLine portal. Follow the instructions in the Compuware Installer
Mainframe Products SMP/E Installation Guide to apply maintenance.
18
Enterprise Common Components Installation and Configuration Guide
Milestone 2: Configuration Preparation
Milestone 2 tasks are required to begin the configuration for ECC, whether for an upgrade to an existing installation, or for a new product installation. This milestone will assist you to prepare for either upgrading your existing ECC to the current release, or to install the current release of ECC.
Role involved: z/OS Systems Programmer
Task 2.1 Verify APF-Authorize SLCXAUTH Load Library
Compuware recommends that the ECC SLCXAUTH library be APF-authorized to z/OS.
As certain ECC components require that some of their modules be in an APF-authorized library,
Compuware has provided a load library, SLCXAUTH, that contains those modules. APF-authorize only the SLCXAUTH load library.
Instructions:
Follow IBM procedures to complete this task.
Task 2.2 Define Compuware’s Common Parameter Library Dataset
Compuware’s Common Parameter Library (PARMLIB) feature requires a partitioned dataset to be allocated on your system to house PARMLIBs for those Compuware products that employ this configuration tool.
At least one Common PARMLIB dataset must exist to contain Compuware product PARMLIB members, which are accessed by CMSC. If you have already allocated the Compuware PARMLIB dataset, skip this task. Otherwise, define a library.
Instructions:
Modify the sample JCL member CMSCALCP, located in library SLCXCNTL, to allocate the PARMLIB dataset.
1. Update the JCL:
a. Add a job card.
b. Specify an appropriate dataset name for the CPWRPARM DD statement by changing the
CPWR.PARMLIB name. Compuware recommends you add a high-level qualifier to the provided dataset name.
2. Submit the job and review the output to verify successful completion.
Task 2.3 Define HCI’s Default ID
The HCI requires a default user ID to be defined that will be used to start the HCI started task.
19
20
Enterprise Common Components Installation and Configuration Guide
This is a valid RACF (ACF2 or Top Secret) user ID to be used by the HCI when TP jobs are submitted or started and when there is no other user ID available. The user ID can be named anything, but the default value of HCIUSER is listed for the parameter DEFAULT_USER in the HCIALL PARMLIB member.
If HCIUSER is used for this ID, the default value for DEFAULT_USER will be automatically used. If
HCIUSER is not used for this id, then add the DEFAULT_USER parameter to the HCIxx PARMLIB member with a value of the user ID defined.
Ensure that the default user ID has either ACCESS(READ) or ACCESS(EXECUTE) to the STEPLIB DD concatenation used in the CSS TP JCL (CXSS0000) and that it has appropriate access to other datasets that it processes under the default user ID.
Task 2.4 Upgrade or New Installation
If you are upgrading an existing release of ECC, continue with
“Milestone 3: Configuration for an
If you are installing ECC for the first time, continue with
“Milestone 4: Configure LMS for a New
.
21
Milestone 3: Configuration for an Upgrade
If you are upgrading from a previous release of ECC, follow these instructions.
This milestone will assist you in upgrading from an existing release of ECC at your site to the current release.
Role involved: z/OS Systems Programmer
Older releases of ECC—which comprised of a suite of products—must migrate some artifacts in order to be compatible with ECC 17.02. Use the following table to determine which tasks need to be completed based on the release of ECC from which you are upgrading.
Table 1. Determine which instructions to upgrade to 17.02
ECC Release
pre-16.05
Instructions to Follow
Comments
Use conversion utility to create PARMLIB members. Refresh of product libraries required.
16.05
“Task 3.2 Upgrade from 16.05 to
Refresh of product libraries required.
Task 3.1 Upgrade from pre-16.05 to 17.02
This task will assist you in upgrading your existing pre-release 16.05 ECC software to the current release of ECC.
To do so will still require an installation and configuration of the current release of ECC (due to the requirement of having a CMSC address space operational and the combining of separate product libraries into one for all library types), but some of the configuration tasks will be easier to complete.
1. Starting with ECC release 16.05, LMS runs in the CMSC address space. The initialization job(s) no longer run independently. By default, LMS is started by the CMSC in non-CLF mode. If you wish
LMS to run in CLF mode, configure the CLF, LMS_CLIENT, and LMS_SERVER parameters for
CMSC.
2. You must delete the pre-16.05 LMS subsystem before you start the CMSC for the current LMS release. To delete the earlier LMS subsystem, specify FUNCTION(DELETE) in the LMS client
PARMLIB member. This must be accomplished using the job LMS from your pre-16.05 LMS
library using the specified SYSIN PARMLIB, possibly located in member LMINPARM from library LMSCNTL.
3. ECC requires the use of Compuware’s Common PARMLIB. You should copy your pre-16.05 LMS parameters from member LMINPARM in library LMSCNTL to member LMCL00 in the Common
PARMLIB dataset.
For testing ECC 17.02, after upgrading from LMS 4.0, you can override the installation of LMS 4.0 by changing the DEFAULT parameter in ECC 17.02 from DEFAULT(YES) to DEFAULT(YES,FORCE).
You will also need to change the LMS subsystem name, checkpoint dataset, and exit PROC. If during testing of ECC 17.02 you encounter any issues, stop ECC 17.02 and reissue the UPDATE for LMS 4.0.
22
Enterprise Common Components Installation and Configuration Guide
Note: Any products that were checked out or running when the earlier LMS’s subsystem was deleted should be shutdown and restarted. Also, any products that are started between the time the earlier LMS’s subsystem was deleted and LMS is started in the CMSC will fail with a license error.
4. Add the LICENSE_DSNAME parameter to the newly created LMCL00 PARMLIB member. Set the value for the parameter to the name of the current license file. This parameter setting will avoid an enqueue reserve on the license file when attempting to update a license.
5. If you are upgrading from HCI 3.0 to ECC 17.02, Compuware provides a migration utility that converts HCI 3.0 XML parameters and their associated CSS TP configuration parameters into a
PARMLIB member for use with ECC 17.02.
Modify the sample JCL member HCIJMGRT, located in the SLCXCNTL library, to execute the migration utility. The utility writes its output into the specified PARMLIB member, for example
HCI00, replacing any data in the member. The output includes the parameters and their values.
a. Update the JCL:
– Add a job card.
– On the HCIXML DD statement, specify the HCI 3.0 member that contains the HCI XML parameters to be converted.
– On the TPCONFIG DD statement, specify the CSS 9.0 library that contains the TP configuration members.
– On the HCIPARM DD statement, specify the pre-allocated PARMLIB dataset and the member to which we will write the converted data.
– On the SYSTSIN DD statement, specify the library member HCIRMGRT in the EXEC statement that contains the modified JCL.
b. Submit the job and review the output PARMLIB member.
c. Make any additional changes to the new PARMLIB member according to your site’s requirements for the current release of ECC.
If you are upgrading from an HCI release prior to 3.0, you will have to manually update the PARMLIB member with your site’s values.
6. Prior to ECC 16.05, Base Services was part of Abend-AID Common Components. Base Services was removed from Abend-AID 16.05 and became part of ECC beginning with release 16.05. If you are upgrading to ECC 17.02 but not upgrading Abend-AID to release 16.05 or 17.02, then the following procedures must be implemented to allow your existing Abend-AID installation to
function correctly with ECC 17.02.
You may continue to use Abend-AID 12.04 (and below) with your prior version of CSS. However, if you want to change existing Abend0-AID servers to use the ECC 17.02 load libraries then these changes will be needed:
a. BDCAS – in the step that executes program FDBMMPLU:
– Add the ECC 17.02 SLCXAUTH library as the first library on the STEPLIB DD statement.
– Add the ECC 17.02 SLCXLOAD library as the first library on the FDBDRPL DD statement.
– Remove the existing SLCXLOAD library from the FDBDRPL DD statement.
Note: If you have steps to execute program FDBASUBS to start or stop an Abend-AID subsystem, update the STEPLIB DD statement to remove the Abend-AID Common library SKAZAUTH and replace it with the ECC 17.02 SLCXAUTH library.
23
b. TDCAS – in the step that executes program FDBMMPLU:
– Add the ECC 17.02 SLCXAUTH library as the first library on the STEPLIB DD statement.
– Remove the HCI library SLHCAUTH library from the STEPLIB DD statement.
– Add the ECC 17.02 SLCXLOAD library as the first library on the FDBDRPL DD statement.
– Remove the existing SLCXLOAD library from the FDBDRPL DD statement.
– Remove the HCI SLHCLOAD library from the FDBDRPL DD statement.
Note: If you have steps to execute program FDBASUBS to start or stop an Abend-AID subsystem, update the STEPLIB DD statement to remove the Abend-AID Common library SKAZAUTH and replace it with the ECC 17.02 SLCXAUTH library.
c. VIEWING SERVER – in the step that executes program FDBMMPLU:
– Add the ECC 17.02 SLCXAUTH library as the first library on the STEPLIB DD statement.
– Remove the HCI library SLHCAUTH library from the STEPLIB DD statement.
– Add the ECC 17.02 SLCXLOAD library as the first library on the FDBDRPL DD statement.
– Remove the existing SLCXLOAD library from the FDBDRPL DD statement.
– Remove the HCI SLHCLOAD library from the FDBDRPL DD statement.
7. If you have steps to execute program FDBASUBS to start or stop an Abend-AID subsystem, update the STEPLIB DD statement to remove the Abend-AID Common library SKAZAUTH and replace it with the ECC 17.02 SLCXAUTH library.
8. If you installed CSS with your ECC pre-16.05 release, copy your existing CSS Compile Information
Table to the ECC 17.02 library. The Compile Information Table is member AAUTCTBL in library
SLCXTABL.
9. Review and modify started tasks (PROCs) or batch jobs to use 17.02 libraries.
a. HCIPROC
b. LMSEXIT
c. CXSS0000
d. CXSSAS
e. Any others that may have older ECC library names.
10. Because your ECC pre-16.05 release did not include the CMSC component, you need to also complete Milestone 6: Configure CMSC to finish the upgrade.
Task 3.2 Upgrade from 16.05 to 17.02
This task will assist you to upgrade your existing ECC software, release 16.05, to the current release of
ECC.
Instructions:
1. Modify started tasks (PROCS) or batch jobs to use 17.02 libraries.
a. CMSC
b. HCIPROC (only if using the HCI)
c. LMSEXIT
d. CXSS0000
e. CXSSAS
24
Enterprise Common Components Installation and Configuration Guide
2. Remove CWLF0000 DD statement in CMSC started task.
3. Authorize the 17.02 SLCXAUTH library.
4. Execute the LMSPREP CLIST to update the CWLMA CLIST to use the 17.02 libraries. Copy the
CWLMA CLIST to an appropriate CLIST system library, if desired.
5. Update the LMCLxx PARMLIB member:
a. Change DEFAULT parameter value to (YES,FORCE).
b. Change CHKPT_DSNAME value to a new library name.
c. Change EXIT_PROC value to the name of the new PROC.
d. Add LICENSE_DSNAME parameter with the value of the current license file, to avoid enqueue reserve on license file when attempting to update a license.
6. Delete the existing LMS subsystem:
a. Update LMCLxx parameter FUNCTION to DELETE.
b. Refresh the LMCLxx PARMLIB member in storage. f cmsc,parmlib
refresh LMCLxx where cmsc is the CMSC started task name (if modified) and
xx is the suffix for the PARMLIB member (default is LMCL00)
c. Shutdown the LMS subsystem. f cmsc,lmshut client
7. Add the 17.02 LMS subsystem:
a. Update LMCLxx parameter FUNCTION to UPDATE.
b. Refresh the LMCLxx PARMLIB member in storage. f cmsc,parmlib refresh LMCLxx
c. Shutdown the LMS subsystem. f cmsc,shutdown immed
d. Restart the CMSC s cmsc
8. If your HCI is controlled by the CMSC, then shutdown the HCIPROC and restart the CMSC. This will execute LMS to load your Compuware licenses into storage and will start the HCIPROC.
Otherwise, stop and restart your HCI started task or batch job.
9. Copy your existing CSS Compile Information Table (member AAUTCTBL) from the 16.05
SLCXTABL library to the 17.02 SLCXTABL library.
Base Services requires no customization for an upgrade other than the refresh to the current releases libraries.
Task 3.3 Verification
This task will assist you to verify that the CMSC is executing, without any errors, that the LMS subsystem was started, and the HCIPROC was started.
Instructions:
1. Verification of CMSC and LMS
a. View the executing CMSC’s job output and look for the following message in the FDBDLOG:
•
MPLU FDBRC1999I REGION INITIALIZATION COMPLETE FOR SERVER CMSC
This message signifies that the CMSC Server initialized and is ready.
• LMS0 MSCSC2512I THE LMS TASK HAS TERMINATED. DETACHING.
25
• This signifies that the LMS Subsystem was started successfully.
Note: The following message may appear shortly afterwards:
MSCSC2512I THE LMS TASK HAS TERMINATED. DETACHING.
This message states that the LMS task that started the LMS subsystem ended and is detaching.
This is an expected message when LMS is functioning in non-CLF mode.
b. Look for the following messages in the LMCPRINT:
LM6012I UPDATE OF CHECKPOINT DATA SET COMPLETED
LM5021I SUBSYSTEM LMS1 HAS BEEN UPDATED ON SYSTEM CW99
LM5003I HIGHEST RETURN CODE WAS 00000000 AND REASON CODE WAS 0
These messages signify that the LMS subsystem was successfully loaded into the CMSC address space and is available for license validation by a Compuware product.
CMSC is the name you gave for your started task, if modified from our sample.
2. Verification of LMS subsystem
a. Modify the sample JCL member LMLFCRPT, located in library SLCXCNTL, to list the contents of the LMS License File.
• Add a job card.
• On the IMPORT step’s STEPLIB DD statement, update the SLCXAUTH library to your installation’s fully qualified dataset name.
• Modify ‘CPWR.LICENSE.FILE’ to the name of your LMS License File.
• Submit the job and review the output to verify successful completion. Also, verify that all your Compuware License Certificates are listed.
3. Verification of HCI
a. Modify the sample JCL member HCITEST, located in library SLCXCNTL, to execute the verification job. The job will attempt to ping the HCI to validate the connection.
• Add a job card.
• On the IVP step’s STEPLIB DD statement, update the SLCXLOAD library to your installation’s fully qualified dataset name.
• On the IVP step’s SYSIN DD for both the HOSTIP and PORT:
HOSTIP – Must contain the value of the host address in which the HCI is executing. It can be the host DNS name or the host IP address.
PORT – Must represent the port on which the HCI is listening.
• Submit the job and review the output.
If a connection was established, the output should resemble:
Compuware Shared Services TP Connection Verification Utility
Control statement specification:
HOSTIP=MVS1.XYZCORP.COM
PORT=16196
OPEN connection RC = 00, ERRNO=00000
26
Enterprise Common Components Installation and Configuration Guide
SEND data RC = 00, ERRNO=00000
RECV data RC = 00, ERRNO=00000
SEND data RC = 00, ERRNO=00000
RECV data RC = 00,
ERRNO=00000
Connection to the port was successfully validated.
Valid Compuware mainframe product license verified.
Task 3.4 Post-upgrade Considerations
Once you have completed the verification for the upgrade of ECC, you have completed the ECC upgrade. You should NOT perform Milestones 4, 5, 6, and 7, which are instructions strictly for configuring new installations. If you plan to integrate with Topaz Workbench, you should proceed directly to
“Milestone 8: Configure Topaz Workbench Integration”
. Otherwise, you should proceed directly to
.
Topaz Workbench Integration” .
If you DO NOT plan to integrate with Topaz Workbench, you should proceed directly to “Milestone 9:
.
27
Milestone 4: Configure LMS for a New Install
This milestone will describe tasks for setting up and customizing LMS for use by the Compuware products licensed to your organization.
The tasks describe only the most basic elements required to establish a Compuware LMS environment.
Role involved: z/OS Systems Programmer
Task 4.1 Transfer License Certificate to Host System
LMS uses License Certificate files to configure access to Compuware products licensed by your organization. A License Certificate is a text file typically sent to your site via email by Compuware’s
Worldwide License Management team. In order to be used by LMS, a License Certificate must be accessible to z/OS.
Instructions:
1. Locate the License Certificate for the Compuware products being installed. A License Certificate file can contain licensing for more than one Compuware product.
2. Allocate a target dataset on the host system for the License Certificate. Use the DCB parameters
RECFM=FB, LRECL=80, and whatever BLKSIZE you prefer.
3. Transfer the License Certificate to the host using File Transfer Protocol (FTP), IND$FILE, cut and
paste, or any other method desired.
Note: If you open the License Certificate dataset in an IPSF editor or transfer it using cut and paste, make sure NUMBERS is set to OFF.
4. If you have more than one License Certificate file, repeat the process as many times as required.
Task 4.2 Create a License File
This task will assist you to create the VSAM License File required to store your License Certificates for all licensed Compuware software. The License File is fully compatible across all releases of LMS.
If you prefer to use the License Administration Utility (LAU) to manage your License File, directions to do so can be found in the
“Enterprise Common Components Advanced Configuration Guide”
.
Instructions:
Modify the sample JCL LMDELDEF, located in library SLCXCNTL, to allocate and initialize the VSAM
License File.
1. Update the JCL as required:
28
Enterprise Common Components Installation and Configuration Guide
a. Add a job card.
b. Modify all instances of ‘CPWR.LICENSE.FILE’ to the name you prefer. We recommend just changing the high-level qualifier, CPWR.
c. Specify a DASD volume within the ‘DEF CLUSTER’ statement – VOL(*).
d. On the INITLF step’s STEPLIB DD statement, update the SLCXAUTH library to your installation’s fully qualified dataset name.
2. Submit the job and review the output to verify successful completion.
This job performs an IDCAMS DELETE on the specified LICENSE FILE. Use with caution.
Task 4.3 Import License Certificates
This task will assist you to import your Compuware license certificates into the VSAM LMS License
File.
Instructions:
Modify the sample JCL member LMIMPORT, located in library SLCXCNTL, to import Compuware
the License File (created in
“Task 4.2 Create a License File”
).
1. Update the JCL:
a. Add a job card.
b. On the IMPORT step’s STEPLIB DD statement, update the SLCXAUTH library to your installation’s fully qualified dataset name.
c. Modify ‘CPWR.LICENSE.FILE’ to the name specified in
“Task 4.2 Create a License File”
. Refer to LMDELDEF JCL.
d. Modify ‘CPWR.CERTIF.FILE’ to the name specified in
“Task 4.1 Transfer License Certificate to
2. Submit the job and review the output to verify successful completion.
If you have more than one License Certificate file, repeat until all License Certificate files have been imported to the LMS License File.
If you want to change which license file you are using, change the LICENSE_DSNAME parameter to reflect that, then run:
F cmscname,PARMLIB REFRESH
After importing a new certificate into a currently active license file, assuming non-CLF, you need to send the following command to CMSC:
F cmscname,LMRESTRT CLIENT
29
Task 4.4 Verify the License File
This task will assist you to verify that the contents of the License File lists License Certificates for each Compuware software licensed to you.
Instructions:
Modify the sample JCL member LMLFCRPT, located in library SLCXCNTL, to list the contents of the
LMS License File.
1. Update the JCL:
a. Add a job card.
b. On the IMPORT step’s STEPLIB DD statement, update the SLCXAUTH library to your installation’s fully qualified dataset name.
c. Modify ‘CPWR.LICENSE.FILE’ to the name specified in
“Task 4.2 Create a License File”
. Refer to LMDELDEF JCL.
2. Submit the job and review the output to verify successful completion. Also, verify that all your
Compuware License Certificates are listed.
Task 4.5 Create LMS Exit Procedure
This task will assist you to copy, to a system PROCLIB, the LMS Exit procedure and to modify the
PROC as required.
The Exit PROC is used by LMS to establish with z/OS a request for it to be notified when any of the following events occur on the LPAR:
• A dynamic CPU upgrade.
• A change to the defined capacity of the LPAR.
• The first SMF interval to expire each midnight.
Each of these system events causes LMS to be notified via a standard z/OS Event Manager Exit. This exit code examines the state of the LPAR and determines whether it should invoke the PROC named in the EXIT_PROC parameter of the LMS client parameters.
You will notice that the EXIT_PROC is invoked once each day, just after midnight (based upon your installation’s SMF Interval). It is necessary for LMS to update the checkpoint data set with values consistent with the change of date.
Instructions:
1. Copy the sample JCL member LMSEXIT, located in library SLCXCNTL, to a system PROCLIB.
2. Update the JCL: On the EVENT step’s STEPLIB DD statement, update the SLCXAUTH library to your installation’s fully qualified dataset name.
Task 4.6 Customize LMS Parameters
By default, LMS is started by the CMSC in non-CLF mode. However, if you wish to run LMS in CLF mode you must specify the parameters CLF=YES and LMS_CLIENT=YES in all CMSC PARMLIB members. In addition, one CMSC PARMLIB member must contain the parameter LMS_SERVER=YES to indicate that the
CMSC must start the License Management Server component with which the LMS clients communicate.
For more information about these parameters, see the
“Enterprise Common Components Advanced
Configuration Guide”
.
30
Enterprise Common Components Installation and Configuration Guide
Compuware provides two LMS PARMLIB members (LMCL00 and LMSV00), located in SLCXCNTL, that include the core parameters for getting a viable LMS subsystem loaded. Compuware provides two other LMS PARMLIB members (LMCLALL and LMSVALL) that include all the possible parameters defined for use by LMS, and may include parameters with default values.
The four LMS PARMLIB members are split into Client and Server versions:
Client:
• LMCL00 – core parameters essential for proper LMS functionality
• LMCLALL – all parameters (may include parameters with default values)
Server:
• LMSV00 – core parameters essential for proper LMS functionality
• LMSVALL – all parameters (may include parameters with default values)
Instructions:
1. Copy the sample PARMLIB member LMCL00, located in library SLCXCNTL, to your Compuware
PARMLIB dataset (created in
“Task 2.2 Define Compuware’s Common Parameter Library
2. Edit the copied member (LMCL00) to provide values for the following parameters:
• FUNCTION(UPDATE)
This parameter, with the UPDATE value, will define a new SUBSYSTEM_ID value to the table of subsystems.
• LICENSE_DSNAME()
This parameter specifies the license file dataset name to be used.
• SITE()
This parameter specifies a site number that is required for LMS execution. This number tells LMS
which site to load from the license file into the license cache.
DD statements must be included in the LMS JCL named CWLFxxxx DD, where xxxx can be any alphanumeric characters.
• SUBSYSTEM_ID()
This parameter specifies the subsystem identifier that this invocation of LMS will process. This value
can contain only uppercase letters and numbers.
Although the operating system allows subsystem names to contain lowercase letters and special characters, LMS does not because the subsystem name may need to be included in the DDNAME of a
CWIDssss DD DUMMY
statement. Therefore, the value chosen for this parameter must also be
valid in a DDNAME.
You must coordinate the use of the subsystem identifier, because duplicate names are not allowed, either within the set of License Management subsystems, or across all subsystems defined. Verify that the subsystem value chosen is not already in use.
• DEFAULT()
This parameter specifies whether this SUBSYSTEM_ID will be declared the default subsystem.
Your choices are DEFAULT(YES), DEFAULT(NO), or DEFAULT(YES,FORCE).
• CHKPT_DSNAME()
This parameter specifies the name of a checkpoint dataset. LMS requires a checkpoint dataset to be available for LMS and to certain operating system exits at all times. This dataset is created automatically by LMS if it does not already exist, or it is updated if it does exist. You must specify
31
the 1- to 38-character name of this dataset.
Note: The user ID under which LMS is run must have ALTER access to the entity named by this parameter. The IDCAMS utility is dynamically invoked to define this dataset.
• EXIT_PROC()
This parameter specifies the 1- to 8-character member name in your system PROCLIB, of the
PROC which LMS automatically starts whenever an event occurs which drives the event notification exit. The events which will cause this PROC to be started are:
– A dynamic CPU upgrade (CPU upgrade on demand).
– A change to the defined capacity of the LPAR.
– The first SMF interval to expire each midnight.
Note: Refer to
“Task 4.5 Create LMS Exit Procedure” for additional information.
• SMF_ID()
This parameter specifies the SMF Record ID number to be used on all SMF records written by LMS.
The SMF_ID must be a three-digit number in the range of 128 through 255.
If SMF_ID is not specified, then SMF recording will not take place regardless of the specification on any license file concerning this recording. Therefore, this parameter is required before any
SMF recording can occur.
You must coordinate the use of SMF identifiers so that no duplicate numbers are defined to any program or system writing SMF records. Verify to ensure that the SMF_ID value chosen is not
already in use.
Note: Specifying an SMF_ID does not automatically start SMF recording. SMF recording is performed on a product-by-product basis and is activated via an indicator within the file itself.
This parameter and its value only state which SMF_ID will be used when SMF recording is activated.
• ROI_CAPTURE(ABEND-AID,HIPERSTATION,STROBE,FILE-AID,XPEDITER)
Recommended by Compuware and turned on by default. SMF_ID() parameter is required for ROI and must contain an SMF Record ID.
3. To ensure access to Compuware products is automatically enabled, establish a procedure in your system PROCLIB to launch your CMSC as a started task during IPL and IML processing.
4. For non-CLF, or local installations, specify the license file dataset name in the LMCL00 module, under the LICENSE_DSNAME parameter.
5. If you changed your LMS PARMLIB member name from the default LMCL00 (for example:
LMCL0005), update your CMSC PARMLIB member to contain the suffix of the new LMS PARMLIB member, LMCL=0005.
Note: For the complete list of LMS parameters, see the “Enterprise Common Components
Advanced Configuration Guide”
If you have any Compuware products that use Host Communication Interface (HCI), continue with the tasks in
“Milestone 5: Configure HCI for a New Install”
—otherwise, skip to
Configure CMSC for a New Install”
.
32
Enterprise Common Components Installation and Configuration Guide
33
Milestone 5: Configure HCI for a New Install
This milestone will assist you to customize the mainframe components needed to support the host communication from the mainframe.
Skip this milestone if you do not have Compuware products that require HCI on this LPAR. Continue configuration with Milestone 5 – Configure CMSC
Role involved: z/OS Systems Programmer
Task 5.1 Define Journals
This task will assist you to allocate HCI and SSAS journal datasets. These journals are used by the HCI and SSAS jobs to log processing requests and to provide trace information that may be required by
Compuware for problem determination and resolution. The CSS TP journals are only necessary if you are going to deploy the SSAS address space, to enable Compuware DDIO file support, or the Code
Coverage/Eclipse plug-in for Topaz Workbench. See
“Milestone 8: Configure Topaz Workbench
.
Instructions:
Modify the sample JCL member HCIJOURN, located in library SLCXCNTL, to define the VSAM journals. The job will use IDCAMS to define and initialize the journal datasets. Compuware recommends defining three journals for HCI use and two journals for SSAS use, as specified in the sample JCL.
1. Update the JCL:
a. Add a job card.
b. On the ALLOCJH step’s DEFINE statements, provide fully qualified dataset names.
Compuware recommends adding a high-level qualifier to the specified name.
c. On the ALLOCJC step’s DEFINE statements, provide fully qualified dataset names. Compuware recommends adding a high-level qualifier to the specified name.
2. Submit the job and review the output to verify successful completion.
Task 5.2 Implement HCI Procedures
This task will create the PROCs required to start the HCI and to provide support to the HCI. The three
PROCs that will be created are:
• The HCIPROC – is the HCI started task procedure. Optionally, the HCI can be run via a batch job, typically to verify configuration. Compuware recommends that the HCIPROC run as a started task that is managed by the CMSC.
• The CXSSAS PROC – is the Shared Services (CSS) Address Space procedure. The CXSSAS PROC is primarily used for DDIO processing and for Xpediter/Code Coverage analysis. This PROC is designed to execute unauthorized.
34
Enterprise Common Components Installation and Configuration Guide
• The CXSS0000 PROC – is the CSS TP procedure. The CXSS0000 PROC is used to support File-AID and Strobe processing. This PROC is designed to execute authorized.
Instructions:
Modify the sample JCL member HCIPROCS, located in library SLCXCNTL, to create three PROCS.
1. Update the JCL:
a. Add a job card.
b. On the HCIPROC step’s SYSUT2 DD statement, specify a system PROCLIB where the job will write the three PROCs. In the sample JCL, SYS1.PROCLIB is specified, but can be changed to an appropriate PROCLIB for your installation.
c. For the HCIPROC member, on the STEP1 step’s STEPLIB DD statement, update the SLCXAUTH library to your installation’s fully qualified dataset name.
d. For the CXSSAS member, on the IEFPROC step’s STEPLIB DD statement, update the
SLCXLOAD library to your installation’s fully qualified dataset name.
e. For the CXSSAS member, the PARM &TPNAME is a value generated by the CSS TP internally and should not be modified.
f. For the CXSS0000 member, on the IEFPROC step’s STEPLIB DD statement, update the
SLCXAUTH library to your installation’s fully qualified dataset name.
2. Submit the job and review the output to verify successful completion.
Task 5.3 Customize HCI Parameters
This task will assist you to allocate HCI and CSS TP journal datasets.
Instructions:
Customize and run the SLCXCNTL member HCIJOURN to allocate the HCI and CSS TP journal datasets. The CSS TP journals are only necessary if you are going to deploy the SSAS address space to enable Compuware DDIO file support or the Code Coverage/Eclipse plug-in within Topaz
Workbench (see the Topaz Workbench Advanced Configuration Guide).
Task 5.4 HCI Parameter Customization
This task will assist you to customize those parameters required to successfully start the HCI.
Compuware provides a default HCI PARMLIB member (HCI00), located in SLCXCNTL, that includes the core parameters for getting a viable HCI started. Compuware provides a second HCI PARMLIB member (HCIALL) that includes all the possible parameters defined for use by HCI, and may include parameters with default values.
Instructions:
1. Copy the sample PARMLIB member HCI00, located in library SLCXCNTL, to your Compuware
PARMLIB dataset (created in
“Define Compuware’s Common Parameter Library Dataset” ).
2. Edit the copied member (HCI00) to provide values for the following parameters:
• SYSID=HCI0
This parameter specifies your subsystem ID. SYSID must be four characters in length and start with an alpha character or #, $, @. The SYSID is used by the HCI initialization routines to dynamically create a z/OS subsystem. It must be unique among all subsystems running on this
LPAR and must not be defined in a system PARMLIB.
• JOURNALn
35
These parameters (one for each HCI journal defined in
“Define Journals” ) specify journal datasets
that allow for logging of HCI activity. The HCI uses the Journaling Facility to write out diagnostic information that may then be provided to Compuware.
Note: Journal datasets cannot be shared across multiple HCI instances. Each HCI instances requires its own set of journal datasets.
• CPWR_PORT=16196
This parameter specifies a port number in which the HCI listens for incoming connection requests. Check with your network administrator for an available port number.
• PORT_CONFIG=16196
This parameter denotes the start of a CSS TP port configuration and must come after any
required HCI parameter statements.
Any parameter statements below this PORT_CONFIG apply to the value specified for
PORT_CONFIG.
All parameters added to the HCIxx PARMLIB member need to come after the cooresponding PORT_CONFIG for which they pertain.
• NOTIFY=YES
This parameter enables the job notification feature. This feature provides for end-of-job notifications that are generated by the NOTIFY=userid JCL parameter to be sent to the user. The
NOTIFY=userid JCL parameter is used on JOB statements.
Normally, end-of-job notifications are sent to the TSO user. This remains in effect, regardless of whether the NOTIFY feature is enabled or disabled. Enabling the feature allows a copy of the same end-of-job notification to be sent to the user’s Topaz Workbench instance, if started.
• NOTIFY_PURGE=2
This parameter provides an automatic mechanism to purge messages that cannot be delivered to a Workstation user after a set period of days. Messages might be undeliverable because the userid associated with the message never uses Topaz Workbench, or the userid has not used Topaz
Workbench for a period longer than the purge duration period. Purging undeliverable messages reduces overhead and keeps the storage required to maintain the undelivered messages to a reasonable level. The NOTIFY_PURGE duration value is in days.
• STASK=CXSS0000
This parameter specifies the CSS TP Started Task procedure name. The STASK is required for CA-
Endevor, File-AID Data Privacy and/or File-AID/Eclipse plug-in support.
• SSAS_PROC=CXSSAS
This parameter is the Shared Services Address Space procedure name. The SSAS_PROC parameter identifies the JCL procedure name used by the Compuware Shared Services Address Space (SSAS).
• SSAS_NAME=CXSSAS00
This parameter is the Shared Services Address Space. The SSAS_NAME identifies the address space name to be used by the Compuware Shared Services Address Space (SSAS). This address space is intended to run unauthorized functions on behalf of Topaz Workbench.
• LOCAL_PORT=16196
36
Enterprise Common Components Installation and Configuration Guide
This parameter identifies the port number of the HCI that owns this configuration section.
The port number example of 16196 is the port number of the TP assigned to service Topaz
Workbench plug-in connections for this HCI image. This should be the same port number that is specified on the corresponding PORT_CONFIG statement.
• LOCAL_HOST=HOST.NAME
This parameter identifies the host name or the IP address of the HCI that owns this configuration section. If you use an IP address it must be in IPV4 format.
• LOCAL_ZIIP=N
This parameter can enable the zIIP processor of the HCI that owns this configuration section.
This parameter is set to N by default, but can be changed to Y to enable the CSS TP to execute selected portions of TP activity on an available zIIP processor.
• HCI_SYSNAME=CPWR-TP-&SYSNAME
This parameter is the user-specified description for the HCI connection point for a given LPAR.
You must code only one HCI_SYSNAME statement in order to support Host Explorer connections to this LPAR, and it is the same HCI as that coded for LOCAL_* statements.
• HCI_LPAR=&SYSNAME
This parameter is the name of the LPAR that this HCI image will be executing.
You must code only one HCI_LPAR statement in order to support Host Explorer connections to this LPAR, and it is the same HCI as that coded for LOCAL_* statements.
• HCI_PORT=16196
This parameter is the port number of the CSS TP for this HCI image.
You must code only one HCI_PORT statement in order to support Host Explorer connections to this LPAR, and it is the same HCI as that coded for LOCAL_* statements.
• HCI_HOST=HOST.NAME
This parameter specifies the host name or IP address of the operating system image where the
HCI executes. If you use an IP address it must be in IPV4 format.
Note: For a complete list of HCI parameters, see the “Enterprise Common Components Advanced
Configuration Guide”.
Figure 1. Example HCIxx PARMLIB member configured for two ISPW instances
************************************************************************
* HCI -- PARAMETER FILE *
************************************************************************
SYSID=HRA1 HCI SUBSYSTEM NAME
DEFAULT_USER=EFHRJA0 DEFAULT USERID
OPCMD=MODIFY WTOR/MODIFY
JRNL_MASK=0000000000000008
JOURNAL1=HC.DEV.&SYSNAME..HCIRA.JOURNAL1
JOURNAL2=HC.DEV.&SYSNAME..HCIRA.JOURNAL2
JOURNAL3=HC.DEV.&SYSNAME..HCIRA.JOURNAL3
************************************************************************
* HCI – PORT DEFINITIONS *
************************************************************************
CPWR_PORT=17100 PORT DEFINITION – TOPAZ/ISPW CMPROD
TCPNAME=TCPIP09
CPWR_PORT=17200 PORT DEFINITION - TOPAZ/ISPW CMTEST
TCPNAME=TCPIP09
************************************************************************
* PORT CONFIGURATION=17100 *
************************************************************************
PORT_CONFIG=17100 -- CONFIGURATION
STASK=RJA10000 STARTED TASK TP PROCEDURE
SSAS_PROC=RJA1SSAS
SSAS_NAME=RJA1SSAS
ENDEVOR=Y
************************************************************************
* LOCAL SPECIFICATIONS *
************************************************************************
LOCAL_PORT=17100 LOCAL PORT
LOCAL_HOST=&SYSNAME..COMPUWARE.COM LOCAL HOST
LOCAL_ZIIP=N Y/N (ZIIP)
************************************************************************
* SERVICE HCI DEFINITIONS *
************************************************************************
HCI_SYSNAME=&SYSNAME.-TP-PROD 20 CHAR SYSNAME
HCI_LPAR=&SYSNAME HCI LPAR NAME
HCI_PORT=17100 HCI PORT
HCI_HOST=&SYSNAME..COMPUWARE.COM HCI HOST NAME
************************************************************************
* ISPW CONFIGURATION *
************************************************************************
ISPW_HOST=CW09.COMPUWARE.COM
ISPW_PORT=3500
************************************************************************
PORT CONFIGURATION=17200 *
************************************************************************
PORT_CONFIG=17200 -- CONFIGURATION
STASK=RJA10000 STARTED TASK TP PROCEDURE
SSAS_PROC=RJA1SSAS
SSAS_NAME=RJA1SSAS
ENDEVOR=Y
************************************************************************
* LOCAL SPECIFICATIONS *
************************************************************************
LOCAL_PORT=17200 LOCAL PORT
LOCAL_HOST=&SYSNAME..COMPUWARE.COM LOCAL HOST
LOCAL_ZIIP=N Y/N (ZIIP)
************************************************************************
* SERVICE HCI DEFINITIONS *
************************************************************************
HCI_SYSNAME=&SYSNAME.-TP-PROD 20 CHAR SYSNAME
HCI_LPAR=&SYSNAME HCI LPAR NAME
HCI_PORT=17200 HCI PORT
HCI_HOST=&SYSNAME..COMPUWARE.COM HCI HOST NAME
************************************************************************
* ISPW CONFIGURATION *
************************************************************************
ISPW_HOST=CW09.COMPUWARE.COM
ISPW_PORT=3600
37
38
Enterprise Common Components Installation and Configuration Guide
Task 5.5 HCI Verification (HCITEST)
This task will assist you to verify that the HCI was configured correctly by testing your port for connectivity.
If you plan to have CMSC control your HCIPROC, then you can bypass this task for now and revisit it after completing
“Milestone 6: Configure CMSC for a New Install” .
Instructions:
1. Modify the sample JCL member HCITEST, located in library SLCXCNTL, to execute the verification job. The job will attempt to ping the HCI to validate the connection.
a. Add a job card.
b. On the IVP step’s STEPLIB DD statement, update the SLCXLOAD library to your installation’s fully qualified dataset name.
c. On the IVP step’s SYSIN DD for both the HOSTIP and PORT:
• HOSTIP – Must contain the value of the host address in which the HCI is executing. It can be the host DNS name or the host IP address.
• PORT – Must represent the port on which the HCI is listening.
2. Submit the job and review the output.
• If a connection was established, the output should resemble:
Compuware Shared Services TP Connection Verification Utility
Control statement specification:
HOSTIP=MVS1.XYZCORP.COM
PORT=16196
OPEN connection RC = 00, ERRNO=00000
SEND data RC = 00, ERRNO=00000
RECV data RC = 00, ERRNO=00000
SEND data RC = 00, ERRNO=00000
RECV data RC = 00, ERRNO=00000
Connection to the port was successfully validated.
Valid Compuware mainframe product license verified.
• If a connection cannot be established, or there are error conditions present, the output resembles:
Compuware Shared Services TP Connection Verification Utility
Control statement specification:
HOSTIP=MVS1.XYZCORP.COM
PORT=16196
OPEN connection RC = 00, ERRNO=00000
SEND data RC = 00, ERRNO=00000
RECV data RC = 28, ERRNO=00054
The connection was unexpectedly terminated. Possible causes:
* HCI configuration macros HCICNPCB or HCICNTPT are not correctly set.
* The PORT number specified is a secure port via AT-TLS.
* The PORT number specified is an active port, but is in use by another kind of application.
• Different messages could be in the output depending on the exact return code received during execution.
• If a connection to the HCI is established, messages will be issued and will be visible in the HCI
job log. The messages might resemble:
CXTPMAI009I 0001 Init CXTP01 HOBB24DD
CXTPCFG019I 0001 Configuration file CXTP01 successfully processed
CXTPMAI043I 0001 Ping from 10.10.0.200
CXTPMAI007I 0001 Term RC=00000000 FDBK=0 Reason=00000000
39
It is recommended that once the HCI is implemented, it should be set up to run as a started task and included in the IPL startup sequence.
40
Enterprise Common Components Installation and Configuration Guide
41
Milestone 6: Configure CMSC for a New Install
This milestone will assist you to customize the CMSC, which will provide support to all the other
Compuware mainframe products that require the use of the CMSC Common PARMLIB.
Role involved: z/OS Systems Programmer
The CMSC address space is a centralized facility providing license management and Common
Parameter Library Services for Compuware mainframe products. The CMSC also has the ability to automatically start HCI address spaces. HCI address spaces started by the CMSC will automatically restart in the event of a failure
Figure 1. Compuware Mainframe Product Parameter Retrieval flowchart
Product
Start-up
Procedure/Job
Common
Memory
Object
(Storage of Data Structures)
PARMLIB API
Get PARMLIB member from
Common Memory Object
Move to Caller’s (Product)
Buffer
Exit
Task 6.1 Customize CMSC Parameters
Compuware provides a default CMSC PARMLIB member (CMSC00), located in library SLCXCNTL, that includes the core parameters for getting a viable CMSC started. Compuware provides a second
CMSC PARMLIB member (CMSCALL), also located in library SLCXCNTL, that includes all the possible parameters defined for use by the CMSC, and may include parameters with default values.
Instructions:
1. Copy the sample PARMLIB member CMSC00, located in library SLCXCNTL, to your Compuware
PARMLIB dataset (created in Task 2.2).
2. Edit the copied member (CMSC00) to provide values for the following parameter:
42
Enterprise Common Components Installation Guide
• CMSC_ID=CMSC
This parameter specifies the name of the CMSC. This parameter must be a 1 to 4-character string.
The string must consist of letters (A-Z), digits (0-9), or national symbols (@, #, $). It must begin
with a letter or national symbol.
CMSC_ID=CMSC must be specified for the primary CMSC.
Note: For other optional CMSC parameters, see the “Enterprise Common Components Advanced
Configuration Guide”.
If you defined each of the LMCL, HCI, and CSS PARMLIB members with the default suffix of 00, then there is no reason to add these parameters to the CMSCxx PARMLIB member as CMSC will automatically default to LMCL00, HCI00, and CSS00.
Task 6.2 Start the CMSC
This task will assist you to copy, to a system PROCLIB, the sample CMSC JCL. This JCL, once customized, will be used to start the CMSC. The CMSC can be submitted as a batch job, however,
Compuware recommends that the PROC be setup as a started task and added to your installation’s IPL process.
Member CMSC in the SLCXCNTL library contains sample JCL to run the CMSC. Copy the sample JCL to your system PROCLIB, follow the instructions in the member and modify the JCL to your site’s requirements. The JCL can be submitted as a batch job, or can be executed as a started task.
Figure 2.
CMSC Initialization Process
CMSC
Start-up
Procedure/Job
Initialization &
Housekeeping
Common Memory Object
(Storage of Data Structures)
■
Allocation of Common Area
■
Recover existing Common Area
Read Current CMSC Parmlib and Generate Common
Storage Data Structures
Wait for Work
CMSC Parmlib
Instructions:
1. Copy the sample JCL member CMSC, located in library SLCXCNTL, to a system PROCLIB.
2. Update the JCL:
a. On the CMSC00 EXEC statement, update the PARM:
PARM=’name
,CMSC,ssss’
– name is the name of the CMSC. This can be any unique name of your choosing, up to eight
43 characters in length. The only restrictions are that it must begin with a letter or national character, and contain letters, digits, or national characters.
– CMSC identifies the address space being initialized by this JCL as a CMSC.
– ssss specifies the one to four-character suffix for the CMSC PARMLIB member, discussed in
Task 6.1. This parameter will be concatenated with the prefix ‘CMSC’ to construct the name of the PARMLIB member to be used for the CMSC startup parameters. The suffix must follow the rules for PDS members.
b. On the CMSC00 step’s STEPLIB DD statement, update the SLCXAUTH library to your installation’s fully qualified dataset name.
c. On the CMSC00 step’s FDBDRPL DD statement, update the SLCXLOAD library to your installation’s fully qualified dataset name.
d. On the CMSC00 step’s CWPARM statement, update the CPWR.PARMLIB to your installation’s fully qualified Compuware Common PARMLIB dataset name.
3. Start the PROC as a started task or for testing purposes, submit as a batch job.
Task 6.3 Verifying CMSC
This task will assist you to verify that the CMSC is executing, without errors, and that the LMS subsystem was started.
Instructions:
1. View the executing CMSC’s job output:
a. Look for the following messages in the FDBDLOG:
FDBRC1999I REGION INITIALIZATION COMPLETE FOR SERVER CMSC
This message signifies that the CMSC Server was initialized and is ready.
MSCSC2512I THE LMS TASK HAS TERMINATED. DETACHING.
This message indicates the LMS task that started the LMS subsystem has ended and is detaching. This is an expected message when LMS is functioning in non-CLF mode.
b. Look for the following messages in the LMCPRINT:
LM6012I UPDATE OF CHECKPOINT DATA SET COMPLETED
LM5021I SUBSYSTEM LMS1 HAS BEEN UPDATED ON SYSTEM CW99
LM5003I HIGHEST RETURN CODE WAS 00000000 AND REASON CODE WAS 0
These messages signify that the LMS subsystem was successfully loaded into the CMSC address space and is available for license validation by the Compuware product requiring it.
If the CMSC controls your HCIPROC, then revisit
, Please
before continuing with the ECC configuration.
44
Enterprise Common Components Installation Guide
45
Milestone 7: Configure CSS for a New Install
This milestone will assist you to configure CSS for use with Compuware products that utilize the CSS functions.
Skip this milestone if you do not have Compuware products that require CSS on this LPAR. Continue
configuration with “Milestone 8:Configure Topaz Workbench Integration”.
Role involved: z/OS Systems Programmer
Task 7.1 Make CSS Load Modules Accessible to Compuware Products
This task is required so that other Compuware products that need the CSS modules will have access to them.
Instructions:
Ensure that the CSS load modules can be accessed by Compuware products by placing the ECC load library in the STEPLIB or ISPLLIB for individual TSO logon PROCs, and in the STEPLIB or JOBLIB for batch jobs. The ECC load library (SLCXLOAD or a copy of it) should be concatenated in front of any
Compuware product library(ies).
If you have previously installed CSS and referenced the load library in batch jobs, compile PROCs,
CLISTs, or logon PROCs, CSS will be loaded from the STEPLIB, ISPLLIB, or JOBLIB where it is specified rather than from the link list. Compuware recommends that you review these locations and remove or modify the CSS load library DDs as appropriate. If you have any Compuware product that uses CSS from a STEPLIB, ISPLLIB, or JOBLIB concatenation, you should include the
ECC load library in front of the Compuware product in that library concatenation.
You can dynamically allocate the ECC load library as part of the ISPLLIB concatenation. Please refer to Option 1 listed in
“Create the Compile Information Table” for more information.
Task 7.2 Create the Compile Information Table
This task will create the compile information table, which is stored in SLCXTABL and used by the CSS
Utilities and the Topaz Workbench Language Compiler Facility. This table contains information about your compilers, compiler libraries, DB2 pre-compile libraries, CICS translator libraries and other miscellaneous items. A series of ISPF dialog panels will take you through the table creation process.
When you have finished creating the table, you will have to make it available to the CSS Utilities in
“Activate Compuware ISPF Dialogs” .
For the Topaz Workbench Language Compile Facility, the compile information table is accessed to populate the Preprocessor Compile Libraries dialog when the Import button is selected (see Topaz
Workbench Host Explorer User Guide product help in Topaz Workbench).
46
Enterprise Common Components Installation and Configuration Guide
Instructions:
1. Edit member CXUECIN2 in the SLCXCNTL library. To avoid having your modifications overlaid by future maintenance, you should copy this member to a non-SMP/E controlled library that is in your
SYSPROC concatenation. Follow the instructions that are in the member. You will need the name of your ECC panel library, SLCXPENU, and your ECC REXX EXEC/CLIST library, SLCXEXEC.
2. If you placed the member CXUECIN2 in a library that is in your SYSPROC concatenation, then you may invoked the REXX EXEC as follows:
TSO %CXUECIN2
Otherwise, you may invoke it as follows:
TSO EXEC ‘your.dataset.library(CXUECIN2)’
Figure 1. The first panel displayed is the Install Menu:
Compuware CSS Utilities --------- Install Menu --------------------------------
COMMAND ===>
Enter the name of the library, which is used to store the compile information
that you supply from the options below. If the library does not exist, it
will be allocated.
===>
If you have already supplied the compile information in a prior installation
and you want to copy that information to a new library, then enter the
'old' library name below. Use the 'C' option to copy from the library named
below to the library named above.
===>
Enter an option on the command line.
1.) Select compilers
2.) Enter compiler libraries
3.) Enter DB2 IDs and precompile libraries (optional)
4.) Enter CICS IDs and translator libraries (optional)
5.) Enter miscellaneous information
A.) Process options 1 through 5
C.) Copy a prior installation's information to a new library
Press ENTER to process or enter END command to terminate
The first field is the name of the compile information table. All the information entered will be saved in this table. If the file does not exist it will be allocated for you. The second field is used during the
COPY command. See
“Option C.) Copy a Prior Installation’s Information to a New Library” .
Option 1.) Select Compilers
This option displays the available compilers that the Compile Facility supports. In the Select
Compile Facility.
This option must be specified first, with at least one compiler selected.
47
Figure 2. Compile Information Table - Select Compilers (1 of 2)
Compuware CSS Utilities ------- Select Compilers ------------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: +
COBOL:
OS/VS COBOL ===> N (Y/N)
VS COBOL II ===> N (Y/N)
COBOL/370 ===> N (Y/N)
COBOL/MVS ===> N (Y/N)
COBOL/390 ===> N (Y/N)
ENTERPRISE/COBOL ===> N (Y/N)
COBOL5 ===> N (Y/N)
CA OPTIMIZER ===> N (Y/N)
5.1 DDNames ===> N (Y/N)
Assembler:
Assembler H ===> N (Y/N)
High Level Assembler ===> N (Y/N)
PL/I:
PL/I ===> N (Y/N)
PLI/370 ===> N (Y/N)
Press ENTER to process or enter END command to terminate
Figure 3. Compile Information Table - Select Compilers (2 of 2)
Compuware CSS Utilities ------- Select Compilers ------------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: -
CA OPTIMIZER ===> N (Y/N)
5.1 DDNames ===> N (Y/N)
Assembler:
Assembler H ===> N (Y/N)
High Level Assembler ===> N (Y/N)
PL/I:
PL/I ===> N (Y/N)
PLI/370 ===> N (Y/N)
VA/PLI ===> N (Y/N)
ENTERPRISE/PLI ===> N (Y/N)
C Language:
C/MVS ===> N (Y/N)
C/390 ===> N (Y/N)
C/ZOS ===> N (Y/N)
Press ENTER to process or enter END command to terminate
Enter Y in the 5.1 DDNames field, if you are using CA Optimizer and the release 5.1 DDNames
SYSUT7, SYSUT8, and CAISTATS are to be allocated.
Option 2.) Enter Compile Libraries
This option allows you to supply the library names for the compiler you selected in
. The compilers that you selected will have their corresponding arrow indicators highlighted and the field names will be modifiable.
48
Enterprise Common Components Installation and Configuration Guide
Figure 4. Compile Information Table - Enter Compiler Libraries (1 of 4)
Compuware CSS Utilities ------ Compiler Libraries -----------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: +
COBOL Libraries:
OS/VS COBOL ===>
Linkedit SYSLIB ===>
VS COBOL II ===>
Linkedit SYSLIB ===>
COBOL/370 ===>
Linkedit SYSLIB ===>
COBOL/MVS ===>
Linkedit SYSLIB ===>
COBOL/390 ===>
Linkedit SYSLIB ===>
ENTERPRISE/COBOL ===>
Linkedit SYSLIB ===>
Press ENTER to process or enter END command to terminate
Figure 5. Compile Information Table - Enter Compiler Libraries (2 of 4)
Compuware CSS Utilities ------ Compiler Libraries -----------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: - +
Linkedit SYSLIB ===>
CA OPTIMIZER ===>
Linkedit SYSLIB ===>
ASSEMBLER Libraries:
Assembler H ===>
High Level Assembler ===>
PL/I Libraries:
PL/I ===>
Linkedit SYSLIB ===>
===>
PLI/370 ===>
===>
Linkedit SYSLIB ===>
Press ENTER to process or enter END command to terminate
Figure 6. Compile Information Table - Enter Compiler Libraries (3 of 4)
Compuware CSS Utilities ------ Compiler Libraries -----------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: - +
Linkedit SYSLIB ===>
VA/PLI ===>
Run-time LIBRARY ===>
Linkedit SYSLIB ===>
ENTERPRISE/PLI ===>
Run-time LIBRARY ===>
Linkedit SYSLIB ===>
C Language Libraries:
C/MVS ===>
LE LIBs ===>
Compiler SYSMSGS ===>
Linkedit SYSLIB ===>
C/390 ===>
LE LIBs ===>
Press ENTER to process or enter END command to terminate
Figure 7. Compile Information Table - Enter Compiler Libraries (4 of 4)
Compuware CSS Utilities ------ Compiler Libraries -----------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: -
Linkedit SYSLIB ===>
C Language Libraries:
C/MVS ===>
LE LIBs ===>
Compiler SYSMSGS ===>
Linkedit SYSLIB ===>
C/390 ===>
LE LIBs ===>
Compiler SYSMSGS ===>
Linkedit SYSLIB ===>
C/ZOS ===>
LE LIBs ===>
Compiler SYSMSGS ===>
Linkedit SYSLIB ===>
Press ENTER to process or enter END command to terminate
49
50
Enterprise Common Components Installation and Configuration Guide
Figure 8. Compiler Libraries – screen 5 of 5
Compuware CSS Utilities ------ Compiler Libraries --------------------------
COMMAND ===>Use 'Page UP' and 'Page DOWN' to scroll this screen.
Compiler libraries appear in the STEPLIB DD of compile JCL.
SYSLIB libraries appear in the SYSLIB DD of the Linkedit step.
More: +
High Level Assembler===>
PL/I Libraries:
PL/I ===>
Linkedit SYSLIB ===>
PLI/370 ===>
===>
Linkedit SYSLIB ===>
VA/PLI ===>
Run-time LIBRARY ===>
Linkedit SYSLIB ===>
Press ENTER to process or enter END command to terminate
Libraries entered on these screens depend on the compile processors used at your site. The following types of libraries can be entered on this screen:
– Compiler libraries
– SYSLIB libraries
– Compiler dependent libraries
Compiler libraries describe the datasets that contain the compile processor load modules. These libraries are required only if the processor libraries are not already included in the concatenation lists for LPA or LINKLIST. When these libraries are supplied, they will appear in the STEPLIB DD of the compile JCL.
The SYSLIB libraries describe the datasets to be used for the primary resolution of external references by the linkage editor or binder. For example, the L/E library, SCEELKED. When these libraries are supplied, they will appear in the SYSLIB DD of the linkedit step.
Compiler dependent libraries are for those compilers that have additional library requirements. For example, the C language SYSMSGS library or the L/E library, SCEERUN.
Option 3.) Enter DB2 IDs and Pre-compile Libraries
AIf your site has DB2, this option will allow you to define DB2 identifiers and associate the identifiers with DB2 libraries. When an identifier is selected, the associated datasets will appear in the STEPLIB
DD of the pre-compile step and in the SYSLIB DD of the linkedit step. The DB2 IDs will appear on the
Compile Menu.
In the column on the left, type in a DB2 identifier. It can be from one to six characters in length. You may have up to two identifiers with the same name. In addition, you may have up to eight unique
DB2 identifiers.
In the column on the right in
type in the DB2 dataset names that are required to perform the
DB2 pre-compile step.
51
Figure 9. Compile Information Table - Enter DB2 IDs and Precompile Libraries
Compuware CSS Utilities --- DB2 Precompile Libraries --------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: +
These libraries are used in the DB2 precompile step. The ID is displayed
on the 'Compile Menu'. When the programmer selects one of the IDs from
the 'Compile Menu', the ID is matched to the corresponding library name(s)
that are listed here. You may have up to two libraries with the same ID
name. The 'Compile Menu' can display up to 8 unique IDs.
ID DB2 Precompile Libraries
(1) ===> ===>
(2) ===> ===>
(3) ===> ===>
(4) ===> ===>
(5) ===> ===>
(6) ===> ===>
(7) ===> ===>
(8) ===> ===>
(9) ===> ===>
(10) ===> ===>
(11) ===> ===>
Press ENTER to process or enter END command to terminate
For example:
(1) ===> D910S1 ===> ‘SYS1.DSN910.SDSNLOAD’
(2) ===> D910S1 ===> ‘SYS1.DSN910.SDSNEXIT’
(3) ===> DA10S1 ===> ‘SYS1.DSNA10.SDSNLOAD’
(4) ===> DA10S1 ===> ‘SYS1.DSNA10.SDSNEXIT’
(5) ===> DB10S1 ===> ‘SYS1.DSNB10.SDSNLOAD’
(6) ===> DB10S1 ===> ‘SYS1.DSNB10.SDSNEXIT’
There are two D910S1 identifiers. That is the maximum for a single identifier. Also, there are three unique identifiers: D910S1, DA10S1, and DB10S1. You may have up to eight of these.
Option 4.) Enter CICS IDs and Translator Libraries
If your site has CICS, this option will allow you to define CICS identifiers and associate the identifiers with CICS libraries. When an identifier is selected, the associated datasets will appear in the STEPLIB
DD of the translator step and in the SYSLIB DD of the linkedit step. The CICS IDs will appear on the
Compile Menu.
In the column on the left, type in a CICS identifier. It can be from one to six characters in length. You may have up to two identifiers with the same name. In addition, you may have up to eight unique
CICS identifiers.
In the column on the right, type in the CICS dataset names that are required to perform the CICS translator step.
For example:
(1) ===> CTS530 ===> ‘SYS1.CICS530.LOADLIB1’
(2) ===> CTS530 ===> ‘SYS1.CICS530.LOADLIB2’
(3) ===> CTS520 ===> ‘SYS1.CICS520.LOADLIB1’
(4) ===> CTS520 ===> ‘SYS1.CICS520.LOADLIB2’
(5) ===> CTS510 ===> ‘SYS1.CICS510.LOADLIB1’
(6) ===> CTS510 ===> ‘SYS1.CICS510.LOADLIB2’
There are two CTS530 identifiers. That is the maximum for a single identifier. Also, there are three unique identifiers: CTS530, CTS520, and CTS510. You may have up to eight of these.
52
Enterprise Common Components Installation and Configuration Guide
Option 5.) Enter Miscellaneous Information
Information that did not fall within the previous option categories (1 through 4) are found on the
Miscellaneous Settings panel (Figure 10).
Figure 10. Miscellaneous Settings
Compuware CSS Utilities ---- Miscellaneous Settings ------------------------
COMMAND ===>
To prohibit foreground compiles, set the following value to ‘N’.
Foreground Compile ===> Y
Hold Queue Sysout Class ===> X (0-9, A-Z)
Job Statement Exit: (Executed before batch job submission)
Exit ===>
The exit syntax uses the ISPF SELECT service syntax.
For example:
Exit ===> CMD(command) or CMD(command) NEWAPPL(applid) PASSLIB
Press ENTER to process or enter END command to terminate
Foreground Compile: Some sites do not want their staff doing foreground compiles. If you do not want your users doing foreground compiles, then set this field to N. The Foreground literal will not be displayed as one of the preparation options.
Job Statement Exit: This is an exit point in which the JOB card is passed to the stated entity before job submission for the Batch option. The invocation of the exit is also done before the JCL is displayed with the Editjcl option.
The invocation of the exit uses the ISPF SELECT service syntax. The following are examples:
Exit ===> PANEL(panelid) or PANEL(panelid) NEWAPPL(applid) PASSLIB
Exit ===> CMD(command) or CMD(command) NEWAPPL(applid) PASSLIB
Exit ===> PGM(program-name) or PGM(program-name) PARM(parameters) or
PGM(program-name) PARM(parameters) NEWAPPL(applid) PASSLIB
Note: Batch, Editjcl, and Foreground refer to Preparation types on the Compile Menu.
Option A.) Process Options 1 through 5
Entering this option on the command line will cause options 1 through 5 to be displayed sequentially.
Option C.) Copy a Prior Installation’s Information to a New Library
The Copy process will take an existing compile information table with member AAUTCTBL and copy the member to a new compile information table. If the new table already has member AAUTCTBL, a message window appears asking if you want to overwrite the existing member or bypass the update.
This process may be used to create a back-up of your completed compile information table. Also, it may be used to carry existing compile information forward to a new release. Thus, avoiding having to retype the compile information.
Specify C on the command line. In the first field, enter the dataset name that you want to contain the compile information. In the second field, enter the dataset name of an existing compile information table. Press Enter to copy the information.
53
During the installation, you will need the dataset name of the compile information table.
The Compile Menu is displayed below to assist you in your understanding of how the values that you supply during this installation will affect the display of the Compile Menu.
Figure 11. Compile Menu – Compile Facility
Compuware CSS Utilities -------- Compile Menu -------------------- CSS 17.2.0
COMMAND ===>
Primary Commands: Listing (Display output) SEtup (Display general settings)
Compile Profile: DEFAULT - DEFAULT COMPILE PROFILE
_ Display the Compile Profile list
Source Dsname ===> ‘user ID.COBOL.SOURCE(CWXTCOB)’
Preparation ===> EDITJCL (Batch/Editjcl/Foreground)
Language ===> E-COBOL Select From The List Below
(COB/COB2/COB370/COBMVS/COB390/E-COBOL/COB5/COB6/CAOPT/HASM/HLASM/PLI/PLI370)
(VAPLI/E/E-PLI/CMVS/C390/CZOS)
SEL Options:
D – Display settings S – Select the DB2 Precompile libraries
S – Process only and/or the CICS Translator libraries
SEL STEPS DB2 Precompile CICS Translator
--- ------------------- -------------------- ---------------------
_ 1. DB2 Precompile _ D910S1 _ DA10S1 _ CTS530 _ CTS520
_ 2. CICS Translator _ DB10S1 _ D910S2 _ CTS510 _ CTS420
_ 3. Compile _ DA10S2 _ DB10S2 _ CTS410 _ CTS320
_ 4. Linkedit _ DA10S3 _ DB10S3 _ CTS310 _ CTS230
Note: The option references refer to the option number on the Install Menu screen.
If you set the Foreground Compile value to Y in the Miscellaneous Settings screen (Figure 10), then
the Foreground literal appears in the parenthetical list to the right of the Preparation field. If you set the Foreground Compile value to N, then the literal does not appear.
If you selected all the compilers, the parenthetical list under the Language field is generated. The user will select the language they want to use for their compile by placing one of the names from the list in the Language field. The name entered tells the compile facility which libraries to use during the compile.
If you used eight unique DB2 identifiers, the list under the DB2 Precompile field would be similar. If you supplied less than eight unique identifiers, then any supplied would appear in a left to right, top to bottom sequence.
If you used eight unique CICS identifiers, the list under the CICS Translator field would be similar. If you supplied less than eight unique identifiers, then any supplied would appear in a left to right, top to bottom sequence.
Task 7.3 Activate Compuware ISPF Dialogs
This task discusses two different ways to activate the CSS Utilities libraries, included with the
Compuware ISPF Dialogs – dynamically, or at TSO startup.
If you do not plan on using the CSS Utilities, continue with
“Link CSS Utilities Tutorials to Your Main
54
Enterprise Common Components Installation and Configuration Guide
Dynamically allocating the libraries is discussed in Option 1. Allocating the libraries at TSO startup is discussed in Option 2. For more information about CSS Utilities functionality, see the Compuware
Shared Services User/Reference Guide.
Option 1: Dynamically Allocate Libraries when CSS Utilities are Executed
To dynamically allocate the CSS Utilities libraries when CSS Utilities are executed, you must determine how to make the REXX EXECs and CLISTs accessible.
CSS provides sample REXX EXECs and CLISTs for invoking CSS Utilities in library SLCXCNTL. You can allocate this library at TSO logon time, or make the CLIST or REXX EXEC accessible in a userdefined library allocated at TSO logon.
Important: If CSS REXX EXECs or CLISTs are currently used to invoke the CSS Utilities, you must replace them with the latest versions in order to use the new Abend-AID features and
Abend-AID for CICS utility features.
Instructions:
1. Determine whether to use REXX EXECs or CLISTs. Compuware recommends using REXX EXECs; you may find them easier to customize and maintain.
2. Determine whether Japanese and English language support is required, or just English language support.
3. If using REXX EXECs, choose the appropriate REXX EXEC for CSS Utilities using the following table as a guide. If using CLISTs, select one CLIST for CSS Utilities.
Use this REXX EXEC:
CWUTREXE
CWUTREXJ
Or this CLIST:
CWUTCLSE
CWUTCLSJ
For:
CSS utilities, English-only language support, set up or run
Xpediter utilities.
CSS utilities, English and Japanese language support, set up or run Xpediter utilities.
4. Change the library names in the REXX EXECs or CLISTs selected in step 3 to match your site
standards.
An optional ISPSLIB can be used with On-the-Fly processing. See Appendix D in the Compuware
Shared Services User/Reference Guide for details about On-the-Fly processing. You may use an existing skeleton library allocated at TSO logon time, or allocate one at viewer startup by
updating the REXX EXECs or CLISTs selected in step 3.
The CSS Utilities require the SLCXSLIB and SLCXTABL datasets to be concatenated to ISPSLIB and
ISPTLIB respectively. The SLCXTABL dataset was created in “Create the Compile Information Table”
5. Allocate the ECC SLCXCNTL library at TSO logon time, or copy the edited REXX EXECs/CLISTs to a library allocated at TSO logon:
– To allocate the ECC SLCXCNTL library at TSO logon:
Add the library to the SYSPROC concatenation in the TSO logon PROC.
– To make specific REXX EXECs/CLISTs accessible in a library allocated at TSO logon:
Copy the REXX EXECs or CLISTs to an existing SYSPROC library allocated at TSO logon.
6. Users can invoke the CSS Utilities by selecting an option from an ISPF panel (recommended), or by executing a REXX EXEC or CLIST.
– To enable users to select an ISPF menu option:
55
Add one or more of the following lines to an ISPF panel. Note that ‘o’ represents the option to be entered at the menu command prompt. o ‘CMD (%CSS Utilities CLIST name or REXX EXEC name)
– To invoke CSS Utilities by executing a REXX EXEC or CLIST:
Enter the appropriate command at the TSO command prompt.
TSO %CSS Utilities CLIST name or REXX EXEC name
Option 2: Allocate the Libraries at TSO Startup
Allocating the load, panel, and message libraries at TSO logon simplifies maintenance. All TSO users have access to CSS Utilities after logging on to TSO, and upgrades that affect all TSO users can be made in one central location. However, allocating these libraries at TSO logon may be inappropriate. In that case, dynamically allocating the libraries may be a better solution.
Steps to provide access to the load, panel, and message modules at TSO logon time:
1. Concatenate each library as shown:
Table 1. ECC Libraries
Place a DD statement for the load library in the concatenation for STEPLIB or ISPLLIB in your TSO logon PROC
Load Library
SLCXLOAD
Message Library
SLCXMENU
Panel Library
SLCXPENU
EXEC Library
SLCXEXEC
OR
Execute a CLIST or REXX EXEC at logon time that will concatenate the load library to the appropriate DD statement before starting ISPF
Note: Abend-AID for CICS users must place a DD statement for the load library in the concatenation for FDBDRPL in your server startup JCL.
Concatenate the library to ISPMLIB in the TSO logon PROC
OR
Concatenate the library to ISPMLIB in a CLIST or REXX EXEC before starting ISPF
Concatenate the library to ISPPLIB in the TSO logon PROC
OR
Concatenate the library to ISPPLIB in a CLIST or REXX EXEC before starting ISPF
Concatenate the library to SYSPROC in the TSO logon PROC
OR
Skeleton Library
SLCXSENU
Table Library
SLCXTABL
Concatenate the library to SYSPROC in a CLIST or REXX EXEC before starting ISPF
Due to the Compile Facility’s requirement for this library this DD is required.
Concatenate the library to ISPSLIB in the TSO logon PROC
OR
Concatenate the library to ISPSLIB in a CLIST or REXX EXEC before starting ISPF
Concatenate the library to ISPTLIB in the TSO logon PROC
OR
Concatenate the library to ISPTLIB in a CLIST or REXX EXEC before starting ISPF
Notes:
56
Enterprise Common Components Installation and Configuration Guide
– Replace any existing CSS libraries in these concatenations.
– When testing a new install of Abend-AID, if the new Abend-AID load and customization libraries have not yet been placed in the link list, they must be added as explained in the instructions for the SLCXLOAD library. Doing this will prevent text merge error messages when viewing an Abend-AID reports.
– When testing a new install of Abend-AID for CICS, if the new Abend-AID for CICS load library has not yet been placed in the link list, it must be added as explained in the instructions for the
SLCXLOAD library. Doing this will prevent error messages when using the CSS Utilities with
Abend-AID for CICS DDIO files.
2. Add one or more of the following lines to an ISPF panel. Note that ‘o’ represents the option to be
entered at the ISPF menu command prompt: o ‘PGM(CWDDIUFE) NEWAPPL(AAUT)’
Task 7.4 Customize CSS Parameters
Compuware provides a default CSS PARMLIB member (CSS00), located in library SLCXCNTL, that includes the core parameters for having a viable CSS configured. Compuware provides a second CSS
PARMLIB member (CSSALL), also located in library SLCXCNTL, that includes all the possible parameters defined for use by CSS, and may include parameters with default values.
Instructions:
CSS does not have any core parameters that need to be customized. However, for a listing of all available CSS parameters, see the “Enterprise Common Components Advanced Configuration Guide”.
Additional Configuration
Additional configuration considerations can be found in the “Enterprise Common Components
Advanced Configuration Guide”.
CSS Configuration Considerations
This section discusses the additional CSS configuration items that will be detailed in the “Enterprise
Common Components Advanced Configuration Guide”.
Implement the Security Exit Program
The Security Exit program is an optional user-coded module for establishing security at each site. If you want to ensure full security access to file resources, refer to the CSS Security Exit chapter in the
Compuware Shared Services User/Reference Guide for detailed information on using the program.
Because CSS is used by more than one Compuware product, the Security Exit program is executed for each Compuware product that uses CSS. If you are using multiple Compuware products, you must update your Security Exit program to accommodate those products.
If, after reviewing the above-mentioned chapter, you want to implement the security exit, please refer to the “Enterprise Common Components Advanced Configuration Guide” for configuration instructions.
Install Customized Translation Tables
Customized translation tables can be created and are used in other Compuware products, like Abend-
AID.
The default translation tables (mixed-case English for both horizontal and vertical display) are automatically used and unless you are using Japanese support with Abend-AID, you do not have to implement customized translation tables.
57
If you want to implement customized translation tables, please refer to the “Enterprise Common
Components Advanced Configuration Guide” for configuration instructions.
Task 7.5 Link CSS Utilities Tutorials to Your Main Tutorial Panel
This task provides two sample tutorial main menu panels for ISPF and ISPF/PDF. The sample panels,
CXTUTOR and CXR00003, are located in the SLCXCNTL library.
Instructions:
To link the CSS utilities tutorial panels to your tutorial main menu panel (TTUTOR or ISR00003), use the applicable member (either CXTUTOR or CXR00003) as an example.
58
Enterprise Common Components Installation and Configuration Guide
59
Milestone 8: Configure Topaz Workbench
Integration
This milestone contains instructions necessary to integrate with Topaz Workbench.
Task 8.1 Activating Xpediter/Eclipse Support
This task is necessary only if you plan to use the Xpediter/Eclipse plug-in, which is used in conjunction with the Xpediter products.
Instructions:
1. Update the HCIxx PARMLIB member for Xpediter/TSO, if necessary:
a. Add the CSPF parameter to specify the fully qualified name for the Compuware Shared Profile
File dataset, as created and populated by the Xpediter/TSO installer.
b. Add the TSO_* parameters (TSO_SYSNAME, TSO_APPLID, TSO_LOGMODE, and TSO_LPAR) to specify the corresponding system name, APPLID, LOGMODE, and LPAR name values for the four parameters.
c. Add the APPLID parameter(s) to specify one or more VTAM APPLIDs defined for use by
Xpediter/Eclipse.
2. Update the HCIxx PARMLIB member for Xpediter/CICS, if necessary:
a. Add the CICS_SYSNAME parameter to specify the CICS region system name.
b. Add the CICS_SOCK parameter to specify
c. Add the CICS_PORT parameter to specify
d. Add the CICS_HOST parameter to specify
3. Refresh the HCIxx PARMLIB
4. Add the Xpediter/TSO Authorized Load Library, SLXTAUTH, to the HCI PROC, HCIPROC.
5. Restart the HCI.
6. Install the TSO Logon Procedure.
7. Verify integration by configuring and running an Xpediter Debug Session.
Task 8.2 Activating Hiperstation/Eclipse Support
This task is necessary only if you plan to use the Hiperstation/Eclipse plug-in, which is used in conjunction with Hiperstation, to create audit files.
Instructions:
1. Modify the HCI PROC (job HCIPROC) to add the fully qualified Hiperstation library (SQQFLOAD) in the STEPLIB ??? concatenation.
2. Modify the HCIxx PARMLIB member to add the HPERPLIB parameter with a value of the fully qualified Hiperstation panel library, SQQFPENU.
3. Restart the HCI.
4. Use the Compuware menu to start the Hiperstation/Eclipse perspective.
60
Enterprise Common Components Installation and Configuration Guide
5. If the perspective launches and displays audit files, then you have properly activated
Hiperstation/Eclipse support.
Task 8.3 Activating Code Coverage/Eclipse Support
This task is necessary only if you plan to use the Code Coverage/Eclipse plug-in, which is used in conjunction with Xpediter/Code Coverage.
Instructions:
1. Modify the SSAS PROC (job CXSSAS) to uncomment the Xpediter/Code Coverage library
(SLXVLOAD) in the STEPLIB concatenation and to update with the fully qualified name.
2. Restart the HCI.
3. Use the Compuware menu to start the Code Coverage/Eclipse perspective. Use the Cheat Sheet provided to help you get started.
4. If the perspective launches and displays Coverage Analysis results from an Xpediter/Code
Coverage repository, then you have properly activated Code Coverage/Eclipse support.
Task 8.4 Activating ISPW Support
This task is necessary only if you plan to activate the ISPW interface in Topaz Workbench release
18.2.1 or higher. Also required is ISPW release 17.02 with cumulative maintenance applied.
To run multiple ISPW instances on the same LPAR, the ISPW parameters (ISPW_PORT, ISPW_HOST, and
ISPW_CTNAME) must be specified in the HCIxx PARMLIB member after the PORT_CONFIG statement corresponding to that instance.
Instructions:
1. Modify the HCIxx PARMLIB member by adding the following ISPW Configuration parameters:
a. ISPW_HOST=ip_addr
where ip_addr is the IP address, or DNS, of the ISPW server.
b. ISPW_PORT=port_num
where port_num is the ISPW server port and must match the value of WZCMXPRT in the ISPW start parms.
c. ISPW_CTNAME=ct_server_name
where ct_server_name is the name of the ISPW/CT server that should be used by Topaz
Workbench clients to access ISPW life cycle datasets. This parameter is required when the
CTLOCAL value defined to ISPW does not have access to the life cycle datasets used by the
Topaz Workbench clients that are connecting through this HCI. This parameter is used in multi-site implementations with a single ISPW server.
2. Refresh the HCIxx PARMLIB within the CMSC address space.
3. Restart the HCI.
Task 8.5 Activating CA-Endevor Support
This task is necessary only if you plan to activate the CA Endevor interface (the appearance of the
Endevor navigation path in Topaz Workbench’s Host Explorer perspective).
Instructions:
1. Modify the HCIxx PARMLIB member to add the ENDEVOR parameter with a value of Y.
2. Add the Endevor APF-authorized library to the STEPLIB DD in the CSS TP started task (job
CXSS0000 in your system PROCLIB).
61
3. Restart the HCI.
4. In the Host Explorer perspective, select a mainframe LPAR and expand to see the paths.
5. Right-click the Endevor path and select Add Filter.
6. In the New Endevor Filter dialog box, use the Environment menu to view available environments.
The appearance of a list of accessible environments validates that the CA-Endevor interface was properly activated.
62
Enterprise Common Components Installation and Configuration Guide
Milestone 9: Deployment
This milestone provides information to assist in deploying ECC to other LPARs.
Role involved: z/OS Systems Programmer
Task 9.1 Deployment Possibilities
Instructions:
Compuware recommends using one of the following two methods to deploy ECC to another LPAR.
Method 1
As ECC components are critical for most other Compuware mainframe products, you may want to conduct a full installation to ensure a smooth and correct ECC installation for the LPAR.
Method 2
If you do not require, or want to conduct a complete SMP/E installation on another LPAR, you can instead copy the existing SMP/E Target libraries from one LPAR to the other LPAR, then follow the configuration tasks for each of the components.
If there is an existing release of ECC (or existing older releases of the ECC components), you can follow the “Migration” path. Otherwise, use the “New Installation” path.
63
64
Enterprise Common Components Installation Guide
65
Milestone 10: Migration Utility
Migration Utility
The migration utility converts all prior CMSC-compatible parameter members to their latest format.
The member MIGDRIVR is included in SLCXCNTL and provides sample JCL to execute the migration driver. This utility appends the second version (Version 2 or V2) of the parameter delimiter text $$$
V2 END $$$ to the migrated member, and before the previous member where applicable. Various options may be specified on the PARM=operand to further refine the migration process.
NOTE: The CMSC PARMLIB member must not contain the Version 2 delimiter text.
EXEC Parameter Options
MEMBER= Specifies a 1- to 8-character member name filter, or explicit member name. Specifying * will migrate all valid Compuware PARMLIB members, NAME* will migrate all valid Compuware
PARMLIB members prefixed with NAME, and NAME will migrate a valid Compuware PARMLIB member prefixed with NAME.
READONLY= Specifies whether members are to be written to their respective output member or the
FDBDLOG DD. Specifying YES will allow for validating migration output prior to writing the member our permanently. Options are YES or NO.
VERSION= Specifies the PARMLIB version for which the migration driver will output. Specifying
BOTH will output the new PARMLIB member data, the version two delimiter text, and the version one member. Specifying 2 will omit the version one member.
DDs
Compuware PARMLIB has been enhanced to provide a centralized point of validation prior to product startup, a more consistent and simplified syntax, and the means to migrate to a newer version at your discretion.
To enable the latest enhancements, you must be running ECC 17.2 with all cumulative maintenance along with the most current version of the Compuware product(s) with all cumulative maintenance.
Once all ECC instances that share the same Compuware PARMLIB member have been upgraded and the Compuware product(s) the require those ECC instances have been upgraded, you are now ready to migrate the Compuware PARMLIB member at your convenience.
//CWPARM This DD is the concatenation of Compuware PARMLIB datasets that will be used as input to the migration driver. Only valid CMSC PARMLIB members will be processed. If a duplicate member name is found only migration of the first V1 section and the first V2 section will be written to
CWPOUT.
//CWPOUT Optional output dataset to which migrated members are written. This DD is optional but if not specified, and if READONLY=NO is in effect, member updates will be written in place,
66
Enterprise Common Components Installation Guide
Checklist of Milestones and Tasks
Checklist of Milestones and Tasks
Milestone 1: Install ECC
Task 1.1 RFN and SMP/E Install
Milestone 2: Configuration Preparation
Task 2.1 Verify APF-Authorize SLCXAUTH Load Library
Task 2.2 Define Compuware’s Common Parameter Library Dataset
Task 2.3 Define HCI’s Default ID
Task 2.4 Upgrade or New Installation
Milestone 3: Configuration for an Upgrade
Task 3.1 Upgrade from pre-16.05 to 17.02
Task 3.2 Upgrade from 16.05 to 17.02
Task 3.3 Verification
Task 3.4 Post-upgrade Considerations
Milestone 4: Configure LMS for a New Install
Task 4.1 Transfer License Certificate to Host System
Task 4.2 Create a License File
Task 4.3 Import License Certificates
Task 4.4 Verify the License File
Task 4.5 Create LMS Exit Procedure
Task 4.6 Customize LMS Parameters
Milestone 5: Configure HCI for a New Install
Task 5.1 Define Journals
Task 5.2 Implement HCI Procedures
Task 5.3 Customize HCI Parameters
❏
Task 5.4 HCI Parameter Customization
67
11
68
Enterprise Common Components Installation and Configuration Guide
Task 5.5 HCI Verification (HCITEST)
Milestone 6: Configure CMSC for a New Install
Task 6.1 Customize CMSC Parameters
Task 6.2 Start the CMSC
Task 6.3 Verifying CMSC
Milestone 7: Configure CSS for a New Install
Task 7.1 Make CSS Load Modules Accessible to Compuware Products
Task 7.2 Create the Compile Information Table
Task 7.3 Activate Compuware ISPF Dialogs
Task 7.4 Customize CSS Parameters
Task 7.5 Link CSS Utilities Tutorials to Your Main Tutorial Panel
Milestone 8: Configure Topaz Workbench Integration
Task 8.1 Activating Xpediter/Eclipse Support
Task 8.2 Activating Hiperstation/Eclipse Support
Task 8.3 Activating Code Coverage/Eclipse Support
Task 8.4 Activating ISPW Support
Task 8.5 Activating CA-Endevor Support
Milestone 9: Deployment
Task 9.1 Deployment Possibilities
❏
Milestone 10: Migration Utility
Scarica
Pubblicità