Compuware ECC Enterprise Common Components Installation and Customization Guide
Below you will find brief information for Enterprise Common Components ECC. The Enterprise Common Components ECC are a set of software components that provide a common infrastructure for Compuware products. This guide will help you install and customize these components.
Advertisement
Advertisement
Enterprise Common Components
Installation and Customization Guide
MVS Version
Release 3.2
ii
Enterprise Common Components Installation and Customization Guide
Global technical support contact information is available from our Customer
Support Web Site:
http://go.compuware.com/
This document and the product referenced in it are subject to the following legends:
Copyright 1993-2013 Compuware Corporation. All rights reserved. Unpublished rights reserved under the
Copyright Laws of the United States.
U.S. GOVERNMENT RIGHTS-Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in Compuware Corporation license agreement and as provided in DFARS
227.7202-1(a) and 227.7202-3(a) (1995), DFARS 252.227-7013(c)(1)(ii) (OCT 1988), FAR 12.212(a) (1995),
FAR 52.227-19, or FAR 52.227-14 (ALT III), as applicable. Compuware Corporation.
This product contains confidential information and trade secrets of Compuware Corporation. Use, disclosure, or reproduction is prohibited without the prior express written permission of Compuware
Corporation. Access is limited to authorized users. Use of this product is subject to the terms and conditions of the user’s License Agreement with Compuware Corporation.
Abend-AID, Abend-AID Fault Manager, Abend-AID for WebSphere MQ, Abend-AID for CICS, CICS Abend-
AID/FX, XPEDITER, XPEDITER/DevEnterprise, File-AID for DB2, STROBE, UNIFACE, Compuware Shared
Services, CSS, Compuware Viewing Facility, Compuware/VF, Enterprise Common Components, and ECC are trademarks or registered trademarks of Compuware Corporation.
IBM, CICS, DB2, and MVS/ESA are trademarks or registered trademarks of International Business Machines
Corp.
Adobe
®
Reader
®
is a trademark of Adobe Systems Incorporated in the United States and/or other countries.
All other company and product names are trademarks or registered trademarks of their respective owners.
Doc. CWCYIX3D
October 25, 2013.
iii
Contents
Enterprise Common Components Release 3.2. . . . . . . . . . . . . . . . . . . . . . . . . .xiii
CSS Utilities and Batch File Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Compuware Viewing Facility (Compuware/VF) . . . . . . . . . . . . . . . . . . . . 1-4
Language Processor Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
The License Management Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Information Gathering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Required Components and Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Installing ECC Using JCL Customization Facility. . . . . . . . . . . . . . . . . . . . 2-4
ECC Component Prefixes and FMIDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
iv
Sharing CSS DDIO Files With Multiple CPUs . . . . . . . . . . . . . . . . . . . . . . 2-6
CSS Customer Modification Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
CSS Language Processor (LP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6
Language Processor DD Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9
Writing a Listing to a DDIO File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
Testing and Debugging Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
Debugging Production Programs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
CSS Sample Library Members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
The License Management System Functions . . . . . . . . . . . . . . . . . . . . . . 2-15
License Management Administration . . . . . . . . . . . . . . . . . . . . . . . .2-15
Establishing the Runtime LMS Environment . . . . . . . . . . . . . . . . . . 2-15
Validating Product Access Requests During Product Use . . . . . . . . . 2-16
Chapter 3. Receive From Network (RFN) Installation . . . . . . . . . . . . . . . . . . . . . . 3-1
Step 3. Copy SMP/E Installation Dialog from z/OS UNIX to z/OS . . . . . . . 3-3
Step 1. Make Note of HLQ, Global Zone CSI, and Installation File Name . 3-3
Step 2. Select Installation Components . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Step 3. Specify Installation Environment Information . . . . . . . . . . . . . . . 3-5
Step 5. Specify Global CSI Dataset Name . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Step 6. Specify Job Card Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Step 7. Specify SMP/E High-Level Qualifiers . . . . . . . . . . . . . . . . . . . . . . . . 3-9
Step 8. Specify Target and Distribution Zones . . . . . . . . . . . . . . . . . . . . . . 3-9
Step 9. Verify Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Part 3: Install Compuware Shared Services with SMP/E . . . . . . . . . . . . . . . . . 3-13
Step 1. Allocate Libraries and SMP/E Datasets . . . . . . . . . . . . . . . . . . . . . 3-13
Step 2. Initialize the Target and Distribution Zone CSIs. . . . . . . . . . . . . . 3-14
Step 3. Review HOLDDATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
Step 4. Apply the Base Code and Cumulative Maintenance to the Target
Step 5. Accept the Base Code to the Distribution Libraries . . . . . . . . . . . 3-15
Part 4: Configure Compuware Shared Services . . . . . . . . . . . . . . . . . . . . . . . .3-15
v
Step 2. Receive From Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
Step 3. Copy SMP/E Installation Dialog File from z/OS UNIX to z/OS . . 3-17
Step 1. Make Note of HLQ, Global Zone CSI, and Installation File Name . . .
Step 2. Select Installation Components . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
Step 3. Specify Installation Environment Information . . . . . . . . . . . . . . 3-19
Step 5. Specify Global CSI Dataset Name . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
Step 6. Specify Job Card Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
Step 7. Specify SMP/E High-Level Qualifiers . . . . . . . . . . . . . . . . . . . . . . . 3-23
Step 8. Specify Target and Distribution Zones . . . . . . . . . . . . . . . . . . . . . 3-24
Step 9. Verify Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
Part 3: Install License Management System with SMP/E . . . . . . . . . . . . . . . . . 3-27
Step 1. Allocate Libraries and SMP/E Datasets . . . . . . . . . . . . . . . . . . . . . 3-28
Step 2. Initialize the Target and Distribution Zone CSIs. . . . . . . . . . . . . . 3-28
Step 3. Review HOLDDATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29
Step 4. Apply the Base Code and Cumulative Maintenance to the Target
Step 5. Accept the Base Code to the Distribution Libraries . . . . . . . . . . . 3-30
Part 4: Configure License Management System . . . . . . . . . . . . . . . . . . . . . . . .3-30
Step 2. Receive From Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-31
Step 3. Copy SMP/E Installation Dialog File from z/OS UNIX to z/OS . . 3-31
Step 1. Make Note of HLQ, Global Zone CSI, and Installation File Name . . .
Step 2. Select Installation Components . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33
Step 3. Specify Installation Environment Information . . . . . . . . . . . . . . 3-34
Step 5. Specify Global CSI Dataset Name . . . . . . . . . . . . . . . . . . . . . . . . . 3-36
Step 6. Specify job card Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36
Step 7. Specify SMP/E High-Level Qualifiers . . . . . . . . . . . . . . . . . . . . . . . 3-37
Step 8. Specify Target and Distribution Zones . . . . . . . . . . . . . . . . . . . . . 3-38
Step 9. Verify Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
Part 3: Install Host Communications Interface with SMP/E . . . . . . . . . . . . . . 3-42
Step 1. Allocate Libraries and SMP/E Datasets . . . . . . . . . . . . . . . . . . . . . 3-42
Step 2. Initialize the Target and Distribution Zone CSIs. . . . . . . . . . . . . . 3-43
Step 3. Review HOLDDATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
Step 4. Apply the Base Code and Cumulative Maintenance to the Target
Step 5. Accept the Base Code to the Distribution Libraries . . . . . . . . . . . 3-44
Part 4: Configure Host Communications Interface . . . . . . . . . . . . . . . . . . . . . 3-44
Step 2. Create USS Directory and File Structure . . . . . . . . . . . . . . . . . . . . 3-45
Step 3. Copy the Tar File to USS Tarball Directory . . . . . . . . . . . . . . . . . . 3-46
Step 5. Perform SMP/E Receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-47
SMP/E Customization & JCL generation using Media Browser (Option 1) . . . .4-1
vi
SMP/E Customization & JCL generation using ISPF Dialogs (Option 2) . . . . . . 4-2
Step 1. Implement the Security Exit Program (Optional) . . . . . . . . . . . . . . . . . 5-2
Step 2. Install Customized Translation Tables (Optional) . . . . . . . . . . . . . . . . . 5-3
Step 3. Make New CSS Load Modules Accessible to Compuware Products
Step 4. Create the Compile Information Table (Required) . . . . . . . . . . . . . . . . 5-5
Step 5. Activate Compuware ISPF Dialogs (Required) . . . . . . . . . . . . . . . . . . . 5-15
Option 1 — Dynamically Allocate Libraries when Compuware/VF or CSS
Option 2 — Allocate the Libraries at TSO Startup . . . . . . . . . . . . . . . . . . 5-17
Step 6. Link Compuware/VF and CSS Utilities Tutorials to Your Main Tutorial
Step 7. Associate Contact Information File with Compuware/VF (Optional) . 5-20
Step 8. Establish Access to File-AID (Optional) . . . . . . . . . . . . . . . . . . . . . . . .5-21
Step 9a. Allocate and Format Abend-AID Report Shared Directories and
Databases for Abend-AID Release 9.4 and Later Users . . . . . . . . . . . . . . 5-24
Create the Report Shared Directory. . . . . . . . . . . . . . . . . . . . . . . . . . 5-24
Create the Report Databases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24
Step 9b. Allocate and Format Abend-AID Report Files for Pre-Abend-AID
Allocate the Report Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-24
Format the Report Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
Step 9c. Allocate and Format Source Listing Shared Directories and
Create the Source Listing Shared Directory. . . . . . . . . . . . . . . . . . . . 5-25
Create the Source Listing Databases . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
Step 9d. Allocate and Format Source Listing Files . . . . . . . . . . . . . . . . . . 5-25
Allocate the Source Listing Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
Format the Source Listing Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-26
Step 9e. Allocate and Format Abend-AID for CICS Shared Directories and
Create Abend-AID for CICS Shared Directory (Allocate & Format) . 5-26
Create Abend-AID for CICS Transaction Database (Allocate & Format).
Step 10. Implement the Language Processor JCL (Required) . . . . . . . . . . . . . .5-27
Step 10a. Modify the JCL to Run the COBOL Language Processor . . . . . 5-27
Step 10b. Modify the JCL to Run the PL/I Language Processor . . . . . . . .5-29
Step 10c. Modify the JCL to Run the Assembler Language Processor . . .5-31
Step 10d. Modify the JCL to Run the C Language Processor . . . . . . . . . . 5-32
Step 11. Initialize the zIIP Enablement Service (optional) . . . . . . . . . . . . . . . 5-34
vii
System-wide disablement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35
Step 12. Continue with ECC Customization . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35
Step 2. Set up License Administration Utility (LAU) . . . . . . . . . . . . . . . . . . . . . 6-5
Step 7. Prepare an APF Authorized LMSINIT . . . . . . . . . . . . . . . . . . . . . . . . . . 6-14
Step 10. Continue ECC Customization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-17
Appendix A. SMP/E Installation Using GUI Interface . . . . . . . . . . . . . . . . . . . . . . A-1
Upload Product Files and Perform SMP/E Installation. . . . . . . . . . . . . . . . . . . A-2
System Requirements and Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Information on the Media Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Upload and Submit Installation Jobs . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9
SMP/E JCL Uploaded to the Mainframe . . . . . . . . . . . . . . . . . . . . . . . . . A-10
Install Windows and Third-Party Products . . . . . . . . . . . . . . . . . . . . . . . . . . A-11
Installing Windows Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12
Installing Third-Party Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-12
Appendix B. Installing CSS, LMS, and HCI Using ISPF . . . . . . . . . . . . . . . . . . . . . B-1
Step 3. Specify ECC Installation Environment Information . . . . . . . . . . . . . . .B-4
Step 6. Modify Detail Values for Global SMP/E Datasets . . . . . . . . . . . . . . . . . .B-7
Step 8. Specify Component SMP/E High-Level Qualifiers . . . . . . . . . . . . . . . .B-9
Step 9. Specify CSS Target and Distribution Zones . . . . . . . . . . . . . . . . . . . . . .B-9
Step 10. Modify Detail Values for Component Datasets . . . . . . . . . . . . . . . . .B-11
Step 11. Specify LMS Target and Distribution Zones . . . . . . . . . . . . . . . . . . .B-13
Step 12. Specify HCI Target and Distribution Zones . . . . . . . . . . . . . . . . . . . .B-14
Jobs Created by the Installation JCL Customization Facility . . . . . . . . . .B-17
Step 15. Allocate Compuware Global CSI and SMP/E Datasets . . . . . . . . . . . .B-19
Step 16. Allocate Libraries and SMP/E Datasets . . . . . . . . . . . . . . . . . . . . . . . .B-19
viii
Enterprise Common Components Installation and Customization Guide
Step 17. Initialize the Target and Distribution Zone CSIs . . . . . . . . . . . . . . . B-19
Step 18. Receive the Base Code and Maintenance PTFs . . . . . . . . . . . . . . . . . B-20
Step 19. Apply Base Code and Maintenance PTFs to Target Libraries . . . . . . B-20
Step 20. Accept the Base Code and Maintenance PTFs to the Distribution
Step 21. Continue Installation and Customization . . . . . . . . . . . . . . . . . . . . B-22
Executing the JCL Customization Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
Appendix D. Compuware Maintenance Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1
ix
Figures
Sample JCL to Create USS Directory and File Structure .........................................3-45
Compile Information Table - Select Compilers (1 of 2)...........................................5-6
Compile Information Table - Select Compilers (2 of 2)...........................................5-6
Compile Information Table - Enter Compiler Libraries (1 of 4) ..............................5-7
Compile Information Table - Enter Compiler Libraries (2 of 4) ..............................5-7
Compile Information Table - Enter Compiler Libraries (3 of 4) ..............................5-8
Compile Information Table - Enter Compiler Libraries (4 of 4) ..............................5-8
Compile Information Table - Enter DB2 IDs and Precompile Libraries (1 of 2)......5-9
Compile Information Table - Enter DB2 IDs and Precompile Libraries (2 of 2)......5-9
Compile Information Table - Enter CICS IDs and Translator Libraries (1 of 2) ....5-10
Compile Information Table - Enter CICS IDs and Translator Libraries (2 of 2) ....5-11
Compile Information Table - Enter Miscellaneous Information ...........................5-12
x
Enterprise Common Components Installation and Customization Guide
Prepare License Administration Utility - second screen ..........................................6-6
Main Compuware License Management Screen ....................................................6-10
SMP/E Install Dialog, Zone Info and System Utilities Portion................................ A-8
SMP/E Install Dialog, SMS Parameters and Dataset Definitions Portion ................ A-9
®
Products Tab........................................................................................ A-12
Component Distribution Zone Detail Value Entry................................................B-12
Component SMP/E Work Dataset Detail Value Entry ...........................................B-13
Specifying the LMS Target and Distribution Zones ...............................................B-13
Enter Maintenance, HOLDDATA DSNs, and Global CSI DSN................................ C-2
Compuware Shared Services Target/Distribution Zone Information ..................... C-3
Host Communications Interface Target/Distribution Zone Information............... C-3
License Management System Target/Distribution Zone Information .................... C-3
Summary report without a PRODUCTS DD control file......................................... D-4
xi
Tables
Components Utilized by Each Compuware Product ...............................................2-1
REXX EXECs or CLISTs Used to Invoke Compuware/VF and/or CSS utilities.......5-16
SLCXCNTL Sample Library Members for COBOL Language Processor .................5-29
SLCXCNTL Sample Library Members for PL/I Language Processor .......................5-30
xii
Enterprise Common Components Installation and Customization Guide
xiii
Summary of Changes
The following section describes the updates made to Enterprise Common Components release 3.02.00.
Enterprise Common Components Release 3.2
Enterprise Common Components (ECC) 3.02.00 incorporates the following components:
• Compuware Shared Services (CSS) Release 9.0
• License Management System (LMS) Release 4.0
• Host Communications Interface (HCI) update Release 3.0 Revision 9
The following updates have been made to the Enterprise Common Components Release
3.2
• Removal of Base Services documentation from ECC (Base Services resides with
Abend-AID beginning with release 11.03.00)
• Addition of the Host Communications Interface User/Reference Guide 3.0 to the ECC documentation set.
xiv
Enterprise Common Components Installation and Customization Guide
xv
Introduction
This manual contains instructions for installing, customizing, and maintaining
Enterprise Common Components (ECC).
Enterprise Common Components is essentially a packaging method for the following
Compuware facilities:
• License Management System (LMS)
• Compuware Shared Services (CSS)
• Host Communications Interface (HCI)
Manual Structure
This Enterprise Common Components Installation and Customization Guide is composed of the following chapters:
Chapter 1, “ECC Overview”: A description of the individual components that make up
Enterprise Common Components with overview information on each of the parts. These include: ECC, CSS, LMS, and HCI.
Chapter 2, “Preparing for ECC Installation”: Critical information for planning your
installation of ECC including the LMS, CSS, and HCI components. This chapter also lists which components are required based on your Compuware product, and also lists the libraries that are created during installation with SMP/E.
Chapter 3, “Receive From Network (RFN) Installation”: Step-by-step instructions for
SMP/E installing Compuware Shared Services, License Management System, and Host
Communications Services using Receive From Network (RFN) procedures.
Chapter 4, “Applying Maintenance”: Mandatory step-by-step instructions for applying
maintenance to your installation of ECC.
Chapter 5, “CSS Customization”: Step-by-step instructions for customizing your
installation of CSS and the Compuware Viewing Facility (Compuware/VF).
Chapter 6, “LMS Customization”: Step-by-step instructions for setting up and
customizing LMS for use with the Compuware products licensed by your organization.
Appendix A, “SMP/E Installation Using GUI Interface”: Step-by-step instructions for
SMP/E installing Compuware Shared Services, License Management System, and Host
Communications Services using the Compuware GUI interface (media browser).
Appendix B, “Installing CSS, LMS, and HCI Using ISPF”: Step-by-step instructions
required to install the primary portions of Compuware’s Enterprise Common
Components (ECC) using ISPF.
Appendix C, “JCL Customization”: Describes the usage of the ECC Component JCL
Customization screen.
Appendix D, “Compuware Maintenance Utility”: Explains the purpose and function of
the Maintenance Utility for reporting all currently applied PTFs to a system, for all specified Compuware mainframe products.
Intro
xvi
Enterprise Common Components Installation and Customization Guide
Intended Audience
This manual is intended for installers and application programmers. It is only to be used for installing the MVS/ESA, OS/390, and z/OS versions of Compuware products.
Related Publications
For more information about CSS, LMS, or HCI refer to the Compuware documentation shipped with the ECC CD. For more information about Distributed Viewing Support, refer to the Abend-AID Installation and Customization Guide or Abend-AID for CICS Installation
and Customization Guide. Instructions for accessing this documentation are given in the following paragraphs. For more information on compiling COBOL, PL/I, Assembler, or
C/C++ programs, refer to the appropriate IBM manuals.
FrontLine Support Web Site
Access online technical support for Compuware products through our FrontLine support
Web site. View or download documentation, frequently asked questions, and product fixes, or e-mail Compuware with questions or comments. To access FrontLine, you must first register and obtain a password at http://frontline.compuware.com.
Online Documentation
Documentation for this product is provided on the installation CD-ROM in PDF format.
The following electronic formats are available on http://frontline.compuware.com:
• View PDF files with the free Adobe Reader, available at http://www.adobe.com.
• View HTML files with any standard Web browser.
• View BookManager softcopy files with any version of IBM BookManager READ or the
IBM Softcopy Reader. To learn more about BookManager or to download the free
Softcopy Reader, go to http://www.ibm.com.
World Wide Web
Compuware’s site on the World Wide Web provides information about Compuware and its products. The address is http://www.compuware.com.
Notation Conventions
This section describes common terms and syntax conventions used in this manual. A change bar (|) indicates an update to the manual for this release.
Terminology
The following terms are defined as they are used in this manual:
• DDIO (Dump Dataset Input Output) file is used generically to mean any of the following types of files created by the CSS utilities:
– Report File
– Source Listing File
– Transaction Databases and Shared Directories
– Report Shared Directory and Database
– Source Listing Shared Directory
Introduction
xvii
– Source Listing Database.
For a list of Compuware products that use/require these types of DDIO files, see
Chapter 5, “CSS Customization”.
• Member is used to identify an individual diagnostic report in an Abend-AID report file, a source listing in a source listing file, or a profile in a profile file.
• Entry is used to identify an individual transaction diagnostic report in a transaction database for Abend-AID for CICS.
Getting Help
Compuware continually strives to improve our software products and documentation.
Feedback from our customers helps us to maintain our quality standards.
While the software should execute according to documented specifications, there are times when problems do occur. If problems arise, check the Compuware manuals for assistance. You may also need to consult your site’s technical representative for
Compuware assistance.
If you have attempted to solve the problem using the resources listed above and the difficulty persists, contact the Compuware Customer Support Hotline for assistance.
Customer support is also available via our FrontLine Support web site as described in
“Related Publications”.
Please have the following information available before calling. This information will assist the Customer Support personnel in determining the exact cause of your problem in a timely manner.
Note: If you encounter a CSS problem when compiling your program, Compuware
Customer Support staff may need additional information. You can obtain this information by using the CSS Problem Documentation Utility. Refer to the
“Using the Problem Documentation Utility” appendix in the Compuware Shared
Services User/Reference Guide for complete instructions.
1. Use the following sample JCL members to identify the PTFs and/or APARs that have been applied to the respective ECC components’ libraries:
– CXLPTFS or CXLZAPS in the CSS SLCXCNTL library
– $LMLPTFS in the LMS SLMSCNTL library
– $HCLPTFS in the HCI SLHCCNTL library.
These jobs (with the exception of CXLZAPS) will produce a detailed SMP/E report of
PTFs applied to the above components. The CXLZAPS job will produce a more compact/summarized version of the CSS PTF listing.
2. Determine the release number of the ECC-enabled product.
3. For CSS problems, identify the compiler language and the release number being processed.
4. Identify the CICS release in use if the problem involves a CICS product.
5. Identify the operating system release to help determine operating system dependencies.
6. If an abend occurs, note the displacement and the module in which the interrupt occurs.
7. Note the sequence of issued commands that resulted in the abend, the data type, and the programming language being used.
8. Locate your Compuware customer number.
Compuware Customer Support
xviii
Enterprise Common Components Installation and Customization Guide
http://frontline.compuware.com
1-1
Chapter 1.
ECC Overview
This chapter explains the composition of Compuware’s Enterprise Common Components
(ECC) and provides overview information on each of its component parts.
What is ECC?
Enterprise Common Components is the packaging method for the following Compuware facilities:
• Compuware Shared Services (CSS)
• License Management System (LMS)
• Host Communications Interface (HCI)
Which parts of ECC you need to install depends on which Compuware products are licensed by your organization and which parts of ECC have already been installed. All
Compuware products require the License Management System. Many Compuware products use Compuware Shared Services to provide crucial core functionality. Abend-
AID and Abend-AID for CICS requires the HCI component. A table is provided in Chapter
2, “Preparing for ECC Installation” that makes it easy to determine exactly which parts of
ECC you need to install.
Figure 1-1. ECC Composition
Enterprise Common Components
CSS
Used by many
Compuware
Products
LMS
Required by all
Compuware
Products
HCI
Used by many
Compuware
Products
Each of the following components are installed using SMP/E and can be installed individually, depending on your site’s requirements:
• Compuware Shared Services (CSS): An enterprise-wide tool for sharing compiled program information, CSS is utilized by many Compuware products spanning the
Fault Management and Enterprise Testing Solutions product lines. For more
information, see “CSS Overview” on page 1-2.
• License Management System (LMS): Using LMS enables you to manage access to all the Compuware products used by your organization. LMS consists of several small components which allow you to establish, maintain, diagnose, and upgrade your access to the Compuware products licensed by your enterprise:
1-2
Enterprise Common Components Installation and Customization Guide
– An ISPF License Administration Utility application
– A runtime environment
– A program interface to the runtime environment employed by Compuware products.
LMS License Certificates are English-like text files that are sent to you electronically.
You will receive a License Certificate for each new product release under LMS. You can centrally manage all of your organization’s License Certificates in a single
License File that can then be distributed to various sites.
• Host Communications Interface (HCI): The Host Communications Interface is a facility that provides connectivity between mainframe-based programmer productivity software and peer-node software running on other platforms in a network. The HCI also serves as a server activation facility that is responsible for starting and monitoring application programs that are using the communications facilities.
Note: HCI is a required component for Abend-AID for CICS and Abend-AID users, as well as users of Compuware Workbench and associated features.
CSS Overview
Compuware Shared Services (CSS) is an integral component of many Compuware products spanning the Fault Diagnosis, Interactive Analysis and Debugging, File and Data
Management, and Application Performance Measurement product lines. CSS provides storage, retrieval, and maintenance for Abend-AID reports, source listings, and transaction dump information in datasets called DDIO files. Shared directories and their attached databases are also types of DDIO files being utilized for more efficiency in maintaining information and activity within these files. CSS also provides language processing support for COBOL, PL/I, Assembler, and C.
The following products currently use CSS:
• Abend-AID
• Abend-AID for CICS
• Xpediter/CICS
• Xpediter/TSO and Xpediter/IMS
• Xpediter/Code Coverage
• Strobe
• Benefits of CSS
Prior to CSS Release 1.0, the components that make up CSS were distributed within each product library. For customers with multiple Compuware products, the result was a high degree of redundancy within their product libraries and a complex system of product maintenance. By combining components used by several products into a single unit, CSS provides:
• Easier Installation — All CSS components can be installed at one time rather than piecemeal during installation of other Compuware products.
• Simplified Maintenance — All maintenance to CSS components is applied to ONE set of libraries. It is no longer necessary to search through each product library, determine if a fix must be applied, and then apply the same fix to multiple libraries.
• Frequent New Release Updates — New release updates are made available more frequently.
• Disk Storage — CSS programs and subroutines reside in a separate library.
Compuware customers with multiple products installed can recover disk space previously used by duplicate modules and programs using CSS.
ECC Overview
1-3
• Fewer JCL Changes — The need to change CICS Load Library Definition, TSO logon
PROCs, compile PROCs, and/or rundecks is reduced or eliminated because a central library exists for all products using CSS. This helps to simplify installation.
• Separate Documentation — Documentation for common components is no longer imbedded in the individual product manuals. In addition to your product documentation, you also receive the Enterprise Common Components Installation and
Customization Guide, Compuware Shared Services User/Reference Guide, Enterprise Common
Components Messages and Codes and Host Communications Interface User/Reference Guide.
You no longer need to hunt through the product manuals for information on formatting DDIO files, printing reports and listings, and setting the parameters to run the language processors. Additionally, this ECC documentation set provides greater detail on processing options and customization than was previously available.
System Environment
For System Requirement information, see the Enterprise Common Components Release
Notes available from GO/Frontline, Compuware’s Customer Support web site.
CSS Components
CSS consists of the following components:
• Compuware common files and utilities
– DDIO files: Source Listing Files, Report Files, Shared Directories and Associated
Report, Transaction, and Source Listing Databases
– Batch file utilities: CWDDSUTL, CWFXSDUT, CWAASDUT, CWDDLPUT, and
CWDDALLU
• Compuware Viewing Facility (Compuware/VF)
• Compuware Language Processors (COBOL, Assembler, PL/I, and C)
• Security Exit Program
Common Files and Utilities
CSS components include common files and utilities that provide storage, retrieval, and maintenance functions.
DDIO Files
A generic term used to describe the proprietary file access method that stores Abend-AID reports, transaction dump information, and source listings for several Compuware products. DDIO files can be allocated as either VSAM or sequential datasets. Different products may require different types of DDIO files.
For detailed information on allocating and formatting DDIO files, see the “Allocating and Formatting DDIO Files” chapter in the Compuware Shared Services User/Reference Guide.
CSS Utilities and Batch File Utilities
CSS Utilities walks you step-by-step through CSS language processor functions and DDIO file manipulation using easy-to-use panels.
The batch file utilities (CWDDSUTL, CWAASDUT, CWDDLPUT, CWFXSDUT and
CWDDALLU) provide the same functions as CSS Utilities in a batch environment.
1-4
Enterprise Common Components Installation and Customization Guide
For information on the available online utility functions refer to the “CSS Utilities” chapter in the Compuware Shared Services User/Reference Guide. For information on the available batch utility commands and parameters for CWDDALLU or CWDDSUTL,
CWAASDUT, CWFXSDUT and CWDDLPUT refer to the “Batch File Utility CWDDALLU” chapter in the Compuware Shared Services User/Reference Guide.
Compuware Viewing Facility (Compuware/VF)
The Compuware Viewing Facility (Compuware/VF) provides immediate, online, menudriven access to reports and source listings. From Compuware/VF, you can view a directory that summarizes the members in a DDIO file. You can then access the source listing or Abend-AID report from the directory. While viewing an Abend-AID report, you can directly access any available section of the report, search for particular date or currency formats within the report, or link to Compuware File-AID (to use the BROWSE or EDIT functions only).
Compuware/VF has many features that enable you to view DDIO files easily and quickly.
Its navigation commands let you directly access desired report sections to eliminate cumbersome scrolling. From Compuware/VF you can view, print, lock, unlock, and delete members in a DDIO file online. The members can easily be manually locked to ensure that they remain stored on the DDIO file until you unlock them. Compuware/VF also lets you print members at view time.
Compuware/VF enables you to access the following types of DDIO files:
• Abend-AID reports
• Abend-AID, Abend-AID for CICS, Xpediter/TSO, and Xpediter/CICS source listings.
Note: Viewing access to Abend-AID for CICS source listing files is also provided by the Abend-AID for CICS view server. Abend-AID for CICS users do not need to install Compuware/VF if a server has already been configured to support viewing access. Compuware/VF may be installed, however, in order to view other products’ source listing files.
Note: Beginning with Abend-AID 11.02.00, the Abend-AID viewing server must be used to view Abend-AID reports. Reports created with Abend-AID 11.01.00 and earlier will canstill be viewed with the Compuware Viewing Facility, but use of the Abend-AID viewing server is recommended instead.
CSS Language Processors (LP)
The language processors capture information about a compiler listing and store it in a source listing DDIO file. The majority of this information is gathered from the compiler listing, but optionally, SYSIN and SYSLIB are also examined. The source listing DDIO file may be in standard DDIO, shared directory, or database format.
A language processor can be run using two methods:
• preprocessor
• postprocessor
You may use the preprocessor or postprocessor (whichever is best for your site as needed.)
For information about the pre- and postprocessors, refer to the appropriate language processor chapter in the Compuware Shared Services User/Reference Guide.
Language Processor Types
CSS provides language processing support for the following languages:
• COBOL
• PL/I
• Assembler
ECC Overview
1-5
• C
The COBOL language processor reads the compiler listing produced by the COBOL compiler and writes either a compiler listing or an enhanced listing to the DDIO file. The enhanced listing merges the information normally found in the data division map
(DMAP) and the condensed listing (CLIST) or procedure map (PMAP) into the source statement lines. The COBOL compiler options in effect are sorted alphabetically and appear at the beginning of the enhanced listing. The enhanced listing provides you with a condensed hardcopy of the compiler information.
The COBOL and PL/I listings may be used to provide source support during a debugging or diagnostic session using any of the following products:
• Abend-AID
• Abend-AID for CICS
• Xpediter/CICS
• Xpediter/TSO
• Xpediter/Eclipse
The Assembler listings may be used to provide source support during a debugging or diagnostic session using any of the following products:
• Abend-AID
• Xpediter/CICS
• Xpediter/TSO
• Xpediter/Eclipse
The C language processor reads the compiler listing produced by the C compiler and writes the compiler listing to the DDIO file and SYSCPRT. The source listing in DDIO can then be used to provide source support during a debugging or diagnostic session using:
• Xpediter/TSO
• Xpediter/CICS
Security Exit Program
CSS also includes the Compuware Security Exit Program. This is an optional user-written exit for your Compuware products. It can be used in conjunction with your existing security package to secure sensitive data used by the following Compuware products:
• Abend-AID
• Abend-AID for CICS
• Abend-AID Fault Manager
• Xpediter/CICS
• Xpediter/TSO and Xpediter/IMS
• Xpediter/Code Coverage
• Strobe
The Compuware Security Exit enables you to control access to DDIO file members or restrict access to various commands through a user-written exit program. For the Abend-
AID for CICS product, you can restrict access to some of the CWFXSDUT and
CWDDALLU functions for transaction database and source listing files. For transaction databases, you can use the Security Exit Program to restrict access to individual dumps within a transaction database.If you install a Security Exit program, it will be called by all
Compuware products installed at your site. For more information on the Security Exit
Program, see the “CSS Security Exit” chapter in the Compuware Shared Services User/Reference
Guide.
1-6
Enterprise Common Components Installation and Customization Guide
Executing CSS
CSS is primarily executed at the following times:
• Abend-AID and Abend-AID for CICS
– at compile time (when source support is used)
– at time of abend or application program failure
– at view time when using Compuware/VF or the Abend-AID Viewer
– at installation and maintenance time when formatting a DDIO file.
– when a compile listing that has been stored elsewhere is needed for Abend-AID or Abend-AID for CICS viewing with source support.
• Xpediter/TSO and Xpediter/CICS
– at compile time (when source support is used)
– at execution time for interactive debugging
– at view time when using Compuware/VF
– at installation and maintenance time when formatting a DDIO file.
LMS Overview
LMS is located on the ECC CD-ROM included in the product shipping package. LMS enables you to centrally administer Compuware’s product License Certificates and manage access to Compuware products at your site. LMS includes several components that together enable you to establish, maintain, diagnose, and upgrade access to the
Compuware products licensed by your enterprise.
LMS Advantages
LMS provides the following advantages:
• Electronically-delivered License Certificates that contain product access parameters in a human-readable text format
• Programs and reports to verify the contents of the License File and LMS runtime environment
• Capability to employ a single centralized Enterprise License File and centralized administration of License Files
• Easy updates to License Certificates and the License File with no disruption to your
Compuware products
• No production impact from the testing of LMS runtime systems, installation and validation of new License Certificates, or installation of new or updated LMS software
• Optional E-mail alerts and SMF logging when licensing events occur.
Operating Environment
LMS operates under IBM MVS/ESA Release 4.3 and more current, and all OS/390 and z/OS releases.
The License Management Process
The license management process begins when you acquire a Compuware product through a license agreement, trial agreement, or beta agreement.
ECC Overview
1-7
Information Gathering
Compuware obtains the relevant information for license management from you at the time of the agreement. Your organization supplies information such as name and the sites and CPUs for which the product is being licensed. Information about the
Compuware product licensed, such as product name, release number, and options licensed, is obtained from your Compuware representative.
License Certificate
Upon the completion of an agreement, Compuware creates a License Certificate representing a portion of the information in that agreement. The License Certificate is used by LMS to provide access to Compuware products. The License Certificate is not the same thing as a license agreement. You are still responsible for abiding by your license agreement, and although not its primary role, you will find that the LMS can help in that effort.
The License Certificate, LMS, and the Compuware product are all delivered to you by
Compuware. Typically, you receive the License Certificate via e-mail, but other methods can be used, if necessary.
Installation
The first time your enterprise receives LMS, you must install the LMS software. Then you set up your LMS environment, import your License Certificate into a License File, activate the Runtime License Management System, and install your Compuware product. From then on, access to your Compuware mainframe products occurs transparently.
After you accomplish the initial LMS installation, you would typically only need to import a new product License Certificate and re-initialize the LMS runtime environment in conjunction with events such as the following:
• obtaining a new release of a product under the terms of your software maintenance agreement
• adding new products through additional license agreements
• amending your agreement to include new options
• changing the CPUs licensed in your original agreement.
HCI Overview
The Host Communications Interface (HCI) is a facility that provides connectivity between mainframe-based programmer productivity software and peer-node software running on other platforms in a network. These communications facilities provide a simple application programming interface so that Compuware software can be written to communicate with peer programs running on different platforms. Additionally, the communications system is flexible, simple to operate, and reliable. It has been designed to support open-ended communications protocols, and it can operate on older releases of the MVS operating system. It allows application programs to communicate over any one of several protocols without knowing which protocol is in use at any given time.
The HCI also serves as a server activation facility that is responsible for starting and monitoring application programs that are using the communications facilities.
And finally, the HCI has been designed with no architected upper limit on the number of concurrent sessions supported, nor on throughput rates. The following figure shows how the HCI fits into the scheme of the TP application and the MVS subsystem components.
1-8
Enterprise Common Components Installation and Customization Guide
Figure 1-2. TP Subsystem, HCI and Application. HCI Position as Middleware
TCP/IP
Application
Application
HCI
VTAM
Application
2-1
Chapter 2.
Preparing for ECC Installation
This chapter contains important information that can help you prepare to install the
Enterprise Common Components (ECC) CD-ROM in the most efficient manner. Review it before beginning the installation process.
Required Components and Procedures
This section explains how to determine which parts of ECC need to be installed at your site and which chapters in this manual contain the applicable installation and customization procedures.
Component Selection
Different Compuware products utilize different portions of ECC. Use Table 2-1 to
determine which parts of ECC are needed at your site.
Notice that Compuware’s License Management System (LMS) is required for every mainframe product, while HCI and CSS are components for some products.
DVS can be used with the following products:
• Abend-AID version 9.0 or later
• CICS Abend-AID/FX version 4.4 or Abend-AID for CICS version 4.5 or later
Table 2-1.
Components Utilized by Each Compuware Product
Compuware Product LMS CSS
Abend-AID x x
Abend-AID Fault Manager
Abend-AID for CICS
DBA-XPERT for DB2
File-AID/Data Solutions
File-AID for DB2
File-AID for IMS x x x x x x x x
File-AID/MVS
File-AID/RDX
Hiperstation
STROBE
UNIFACE
Xpediter/CICS
Xpediter/Code Coverage
Xpediter/DevEnterprise
Compuware Workbench/MMC x x x x x x x x x* x x x x
HCI
x x x**** x** x** x
2-2
Enterprise Common Components Installation and Customization Guide
Table 2-1.
Components Utilized by Each Compuware Product
Compuware Product LMS CSS
Xpediter/TSO and IMS x x
HCI
Xpediter/Xchange x
* CSS is required only if creating profiles with source code indexing. CSS minimum release is 7.8.
** HCI can be optionally installed from the ECC CD. Please refer to the product’s documentation for customization instructions.
**** HCI is only required if using the Hiperstation viewer.
Required Procedures
Determining which chapters to use in this manual is actually very simple:
• Every mainframe Compuware product utilizes LMS. Therefore, every installation of a
Compuware product requires, at a minimum, that the latest maintenance be applied to LMS. So regardless of which product you are installing, you must perform the applicable procedures in the following chapters:
– Chapter 3, “Installing Enterprise Common Components” (if current release has not been previously installed)
– Chapter 4, “Applying Maintenance”
– Chapter 6, “LMS Customization”
• If the Compuware product you are installing requires CSS, you must also perform the
procedures in Chapter 5, “CSS Customization”. To configure Distributed Viewing
Support, see the Abend-AID Installation and Customization Guide.
The information within each chapter will direct you as to which steps apply in your situation.
Note: If you are installing the Host Communications Interface (HCI) components, refer to the appropriate product manual for specific customization/configuration instructions.
ECC Packaging
The ECC product media, which includes LMS, CSS, and HCI, is packaged for installation using System Modification Program Extended (SMP/E). SMP/E is a method developed by
IBM to install software products in the MVS environment.
SMP/E provides enhanced installation management and maintenance tracking capabilities. To facilitate SMP/E, the LMS, CSS, and HCI components are shipped on the
ECC CD-ROM separately from the products. The separate ECC CD contains both the base code and all cumulative, approved maintenance to-date. The ECC CD is shipped with each Compuware product that utilizes the CSS, HCI, or License Management components. To install the ECC, refer to Chapter 3, “Installing Enterprise Common
Components”.
The installation utilizes the Installation JCL Customization Facility consisting of a set of
REXX EXECs, JCL skeletons, and panels. This facility prompts you for the installation information and then builds the necessary jobs required to perform the SMP/E installation. You can also view reporting information from the installation facility, such as parameters and execution information.
Cumulative maintenance for ECC components is available for download from the
Compuware Frontline web site (frontline.compuware.com). It is recommended that you
Preparing for ECC Installation
2-3
periodically download and apply cumulative maintenance to keep your product version current.
SMP/E Installation and Maintenance
This section describes allocating SMP/E zones, SMP/E jobs to be executed, and libraries created during the SMP/E installation.
Allocating SMP/E Zones
SMP/E uses a VSAM cluster called a CSI (Consolidated Software Inventory) to control all product installation and maintenance information. Within a CSI, there are a minimum of 3 zones:
• Global zone
• Target zone
• Distribution zone
If a CSI is shared among several different products, there will be a single Global zone and a separate set of Target and Distribution zones for each product installed as illustrated in
Table 2-2. A site may have many CSIs, each with its own Global, Target, and Distribution
zones.
CAUTION:
To prevent possible conflicts, Compuware strongly recommends that all Compuware products and components distributed via SMP/E share a single Global zone reserved solely for Compuware products. Target and distribution zones should not be shared with other products or different releases of the same product.
If you need to maintain more than one release of CSS at a time under SMP/E control, then they must be installed into separate Target and Distribution Zones. If you try to install CSS into the same Target and Distribution Zones as an existing release, then
the previous release of CSS will be deleted.
Table 2-2.
SMP/E Zones
Target Zone Product 1
Target Zone Product 2
Target Zone Product 3
Global Zone
Distribution Zone Product 1
Distribution Zone Product 2
Distribution Zone Product 3
There are many different ways to allocate the zones. These methods include the following:
• The Global, Target, and Distribution zones may all reside together in a single VSAM cluster.
• The zones may each reside in separate VSAM clusters.
• The zones may each reside in a combination of VSAM clusters.
For example, you could have a single VSAM cluster for your Global zone and combine all the Target and Distribution zones in a second VSAM cluster. Or each set of Target and
Distribution zones may be combined in a single VSAM cluster. Compuware recommends that all zones be placed in separate VSAM clusters so that each zone can be backed up and restored individually, if necessary, without impacting any other zone.
2-4
Enterprise Common Components Installation and Customization Guide
Installing with SMP/E
The SMP/E portion of the installation process for LMS, CSS, and/or HCI consists of four basic steps:
1. Allocate and initialize the SMP/E datasets
2. Receive base and maintenance
3. Apply base and maintenance
4. Accept base and maintenance
After a function or maintenance (such as a PTF) has gone through the ACCEPT step, that becomes your current release-base level. At any time prior to the ACCEPT step, you may issue a RESTORE command to reset your Target libraries to the way they were as of the last ACCEPT command. The RESTORE command is used to remove maintenance, or even entire functions, while the ACCEPT command effectively sets a new base level of the release to which further maintenance will be applied. For more information about using the RESTORE command, refer to your site’s IBM SMP/E documentation.
Installing ECC Using JCL Customization Facility
The Installation JCL Customization Facility consists of a set of REXX EXECs, JCL skeletons, messages, and panels contained in the SMP/E installation sample library. The facility will display several panels to obtain installation information, and then will build the necessary jobs required to perform the SMP/E installation. The facility allows you to input SMP/E information, such as the Global SMP/E and SMP/E dataset high-level qualifiers, one time. They can then be used in all SMP/E installation jobs.
Note: Compuware recommends a minimum of ISPF/PDF version 3.5 when using the
Installation JCL Customization Facility. REXX is also required.
Using the Installation JCL Customization Facility, you can install any or all of the following:
• Compuware Shared Services (CSS)
• License Management System (LMS)
• Host Communications Interface (HCI)
Please note the following:
• The HCI component must be installed only if you are using the following products:
– Abend-AID 11.02.00 and greater
– Abend-AID 9.0 through 11.01.00 for Distributed Viewing Support
– CICS Abend-AID/FX 4.4 or Abend-AID for CICS 4.5 or later
• If you need to install more than one component, Compuware recommends simultaneously installing those components.
ECC Component Prefixes and FMIDs
Compuware has registered the following element prefixes with IBM for the ECC components:
• LCX for CSS
• LMS for LMS
• LHC for HCI
The FMIDs for each component are listed below.
• MLCXnnn — CSS base code
Preparing for ECC Installation
2-5
• NLCXnnn — CSS Japanese support
• MLMSnnn — LMS base code
• MLHCnnn — HCI base code
ECC Installation Considerations
This section describes considerations for installing and customizing ECC that applies to
LMS, CSS, and/or HCI. Check your mainframe product installation documentation to verify if these any of the ECC component applications have already been installed. If
they are installed, you may consider only applying maintenance. See Chapter 4,
“Applying Maintenance” for more information.
Link Lists
Refer to your Compuware product documentation to determine whether the load library or libraries for your components should be placed in the link list.
PDS/E Support
ECC components support Partitioned Data Set/Extended (PDS/E) libraries. LMS, CSS, and/or HCI can be installed in PDS/E object libraries. Input source members for the CSS preprocessor or compiled listings for the CSS postprocessor may reside in a data PDS/E library. The following are supported for PDS/E libraries:
• PDS/E object libraries are supported with DFSMS 1.1 and above.
• PDS/E data libraries are supported with DFSMS 1.0 and above.
CSS Installation Considerations
This section describes considerations for installing Compuware Shared Services.
APF Authorization
Following IBM system integrity guidelines, Compuware recommends that your CSS load
Library (SLCXLOAD) NOT be APF-authorized. Depending on your MVS system installation options, libraries placed in the link list may be APF-authorized automatically.
Note: If you are using Abend-AID and Abend-AID is APF-authorized, then CSS should also be APF-authorized. If Abend-AID is not APF-authorized, then CSS should not be APF-authorized. The ONLY time the CSS load library should be APF-authorized is when you are using the Abend-AID load library as APF-authorized.
If you will be installing and configuring the Mainframe Common Components
Mainframe Interface TP, this component does require an APF-authorized library.
However, this component will install into a separate and very small load library
(SLCXAUTH) and the main CSS load library need not be APF-authorized subject to the note above.
CICS Load Library Definition
The CSS library must be included with Compuware product libraries in the CICS startup
JCL or RDO definitions for the following product:
• Xpediter/CICS (all supported releases)
2-6
Enterprise Common Components Installation and Customization Guide
TSO Logon PROCs
If the CSS load library is not in the link list and dynamic library allocation is not used, the CSS load library must be placed before all Compuware product load libraries in the
STEPLIB or ISPLLIB concatenations in the TSO logon PROC. The CSS message and panel libraries must be placed before all Compuware product message and panel libraries in the
ISPMLIB and ISPPLIB concatenations in the TSO logon PROC.
Beginning with CSS 6.0, the CSS load, message, and panel libraries can be dynamically
allocated for use with Compuware/VF. For more information, see “Step 5. Activate
Compuware ISPF Dialogs (Required)” on page 5-15.
Sharing CSS DDIO Files With Multiple CPUs
If you are sharing CSS DDIO files among multiple CPUs, the following qnames must be changed from LOCAL to GLOBAL enqueues.
• ABENDAID
• ABENDDAM
• ABENDSMF
• CWCATALG
Note: These qnames are needed for all products. Please refer to the individual
Compuware product documents with which CSS was distributed for other product requirements.
For IBM’s GRS (Global Resource Serialization), these qnames must be added to the inclusion RNL. This RNL is defined in the GRSRNLxx member of SYS1.PARMLIB for
MVS/XA and later. For pre-MVS/XA systems, these qnames are maintained in the
ISGSIRNL entry point of ISGGRNLO. Please consult the IBM product documentation for further details.
The CSS sample library contains an example of how qnames should be coded in the
GRSRNLxx member of SYS1.PARMLIB. See “CSS Sample Library Members” on page 2-10
for more information.
For resource serialization packages other than GRS (for example MIM), consult the product documentation for changing LOCAL to GLOBAL enqueues.
CSS Customer Modification Facility
The CSS Customer Modification Facility retrofits your site’s CSS restricted zaps to the
SMP/E environment. If you are migrating to the current CSS release from a CSS release prior to CSS 7.4, and have a restricted zaps applied to your system, you must use the CSS
Customer Modification Facility. For more information on using this facility, refer to the
“Using the Customer Modification Facility” appendix in the Compuware Shared Services
User/Reference Guide.
CSS Language Processor (LP)
The language processor captures information about a compiler listing and stores it in a source listing DDIO file. The majority of this information is gathered from the compiler listing, but optionally, SYSIN and SYSLIB are also examined. The source listing DDIO file may be in standard DDIO, shared directory, or database format. Releases prior to
Xpediter/TSO 7.3, Xpediter/CICS 7.6, and Abend-AID for CICS 4.5 do not support source listing shared directories. Instead, individual source databases may be specified for lower levels.
The language processor can be run using two methods:
• preprocessor
Preparing for ECC Installation
2-7
• postprocessor
You may use the preprocessor or postprocessor (whichever is best for your site as needed).
This section discusses the benefits of the preprocessor and the postprocessor and describes when to use them. See the appropriate language processor chapters in the
Compuware Shared Services User/Reference Guide for additional information on determining when to use the pre- or postprocessor.
Preprocessor
Some information about a program module is not always available from the compiler listing. The preprocessor, in addition to gathering information from the compiler listing, gathers information from SYSIN and SYSLIB. The preprocessor provides additional functionality for Xpediter/CICS and Xpediter/TSO, and is required for PL/I programs that use the %NOPRINT statement.
When setting up the language processors, Compuware recommends that you use the preprocessor instead of the postprocessor. The postprocessor should only be used in situations where compiled source listings have been stored.
Preprocessor Steps
1. Determines the proper compiler options required to process the listing file.
2. Automatically invokes the compiler or assembler to compile or assemble your source program.
3. Writes the listing to the DDIO file. An enhanced listing for COBOL programs can be produced, if desired. PL/I and Assembler listings are written to SYSPRINT. C listings are written to SYSCPRT.
Preprocessor Benefits
• Better handling of compiler errors. By using the preprocessor, you can avoid the potential problem of processing a listing with compiler errors. The preprocessor, in conjunction with the CONDDDIO parameter, internally checks the return code from the compiler and doesn’t write a DDIO listing that contains errors. For example, if you set the CONDDDIO parameter to 8, the preprocessor will write the compiler listing to the DDIO file unless the compiler return code exceeds 8. The preprocessor can process the compiler errors more effectively than the postprocessor. Compuware recommends that you use the preprocessor rather than the postprocessor.
• Capturing suppressed source code. When any of the following parameters are used, sections of source code can be suppressed from the compiler listing:
For COBOL
COPY SUPPRESS
For PL/I
%NOPRINT
For Assembler
PRINT OFF or PRINT NOGEN
For C
NOSHOWINC and NOEXPMAC
The preprocessor captures this information from SYSIN and SYSLIB, or by forcing on more revealing compiler options, then altering the listing to emulate the options you requested.
• Automated compiler options. The postprocessor requires that certain compiler options be specified in order to process all needed sections of the compiler listing.
The preprocessor can automatically pass the required options to the compiler.
• Simplified JCL. While the postprocessor requires that the user add a step after the compile step, the preprocessor requires only that minor modifications be made to your existing compile step.
2-8
Enterprise Common Components Installation and Customization Guide
Files Dynamically Allocated
The following files are dynamically allocated by the Compuware preprocessor. The attributes can be overridden by specifying a DD in the JCL.
Table 2-3.
Files Dynamically Allocated by the Preprocessor
DDname Attributes
CWPWRKn (0-6) BLKSIZE=19000 SPACE(TRK,(100,80)) UNIT=SYSDA
SORTWK01
TEMPLIN
BLKSIZE=19000 SPACE(TRK,(100,80)) UNIT=SYSDA
BLKSIZE=3200 SPACE(TRK,(200,100)) UNIT=SYSDA
CWPERRM
SYSPRINT
SYSOUT
SYSOUT=*
SYSOUT=*
SYSOUT=*
CWPPRTI (PL/I) BLKSIZE=19000 SPACE(TRK,(100,200)) UNIT=SYSDA
CWPPRTI (all other languages) BLKSIZE=16093 SPACE(TRK,(100,200)) UNIT=SYSDA DISP=MOD
CWPPDS2 SPACE (TRK,(100,80,80)) UNIT=SYSDA
CWPPRTO is dynamically allocated as a work file (for the preprocessor). SYSPRINT is where the listing goes.
Postprocessor
The postprocessor is executed as a single step and it can be a separate job. It reads in the listing created from the compiler. Information is gathered from the source listing, XREF, data maps, and object code sections of the listing. This information is stored in a DDIO file member and is used by various Compuware products.
While the preprocessor is the preferred method of loading the compiled listing to the
DDIO, there are situations that necessitate the use of the postprocessor as a viable alternative. This is commonly found in production environments where the listings may be archived. In order for the listings to populate the DDIO, they must be compiled using the required options specified in the appropriate language processor chapters in the
Compuware Shared Services User/Reference Guide. Note that these are usually the default options at many shops.
If the programs contain suppressed source code, certain additional control statements must be added to the language processor. Please view the Language Processor chapters in the Compuware Shared Services User/Reference Guide for the programming language desired for more details.
If the programs are compiled with OFFSET as well as OPT(imize), certain additional control statements must be added to the language processor. Please view the Language
Processor chapters in the Compuware Shared Services User/Reference Guide for the programming language desired for more details.
Postprocessor Benefits
• Exact match of compiled output listings with the executable load module. This is especially important in production environments where time is critical.
• Eliminates the risk of copybook or source code changes prior to recompiling the code since the listing reflects the code that is being executed.
• Significantly less time is needed to process source listings as opposed to recompiling the source code.
Preparing for ECC Installation
2-9
Language Processor DD Statements
Table 2-6 lists the DD statements for the Assembler, COBOL, PL/I, and C language processors. Not every DD Name applies to every language processor.
Table 2-4.
Language Processor DD Statements.
DDname Purpose
CWPWRK (0-6) LP work files
CWPPRMO
CWPDDIO
CWPPRTI
CWPPRTO
LP parameter input dataset
Target source listing DDIO file
Compiler listing input to postprocessor
Compiler listing output from postprocessor
CWPLOAD
CWPDECK
CWPERRM
Option LOAD or OBJECT module input to postprocessor
Option DECK module input to postprocessor
LP Error Messages
Note: CWPLOAD and CWPDECK correspond to the SYSLIN and SYSPUNCH compiler outputs. If you specify compiler option OBJECT, you should use CWPLOAD in your postprocessor JCL. If you specify compiler option DECK, you should use
CWPDECK in your postprocessor JCL. Do not feed the SYSLIN output into
CWPDECK or the SYSPUNCH output into CWPLOAD. The updated OBJECT contained in CWPLOAD and CWPDECK should be used in the program’s linkedit step. The preprocessor does not use CWPLOAD and CWPDECK.
Writing a Listing to a DDIO File
Several options exist to place listings in a DDIO file. Each option requires that some changes be made to your JCL. The type of changes needed depend on whether you are using the preprocessor or the postprocessor, and the type of debugging session. Refer to
“CSS Sample Library Members” for a list of the sample JCL that can be used for the
various options.
Testing and Debugging Programs
The actual method used for handling testing and debugging programs depends on whether you are preprocessing or postprocessing:
• Preprocessing — Run the preprocessor and link your program.
• Postprocessing — Compile your program, run the postprocessor, and then link your program.
With either of these methods, the language processor places a listing in the DDIO file whenever a program is compiled.
Debugging Production Programs
If the original compiler listing is available in machine-readable format, you can retrieve the listing and use it as input to the postprocessor in order to reprocess the listing and recreate it in the DDIO file. The postprocessor can process listings stored by most products.
Note: If the listing you use as input to the postprocessor contains any other information
(such as translator or link edit output), in addition to the compiler information, you may not obtain the desired results.
2-10
Enterprise Common Components Installation and Customization Guide
CSS Sample Library Members
The following list describes the members of the CSS sample JCL library that you may work with during installation (depending on your installation options). These members are distributed on the CSS distribution CD and updated via SMP/E. The members will be located in the following files after the Apply and Accept steps are complete.
• COMPWARE.MLCXnnn.SLCXCNTL (target library)
• COMPWARE.MLCXnnn.ALCXCNTL (distribution library) where nnn indicates the CSS release number.
To print the CSS sample library members, submit the JCL contained in library member
CXPRINT after the CD has been unloaded.
CWASSECD
CWASSECU
Security Exit program DSECT.
Sample Security Exit program.
CWCMTRHE
Sample customized horizontal translation table for mixed-case English.
CWCMTRHT
Sample customized horizontal translation table for uppercase English.
CWCMTRHU
Sample customized horizontal translation table for mixed-case English with Euro character.
CWCMTRVE
Sample customized vertical translation table for mixed-case English.
CWCMTRVT
Sample customized vertical translation table for uppercase English.
CWCMTRVU
Sample customized vertical translation table for mixed-case English with Euro character.
Note: The following five members are specific for Abend-AID. They allow browse access to diagnostic reports and source listings directly through ROSCOE or print access via a job submitted from ROSCOE to run in batch. Refer to the members for additional information.
CWROSBAT
ROSCOE sample members.
CWROSBRW
ROSCOE sample members.
CWROSCOE
ROSCOE sample members.
CWROSDIR
ROSCOE sample members.
CWROSPDF
ROSCOE sample members.
CWUTCLSE
Sample CLIST to invoke CSS online utilities with English messages and panels.
CWUTCLSJ
Sample CLIST to invoke CSS online utilities with Japanese messages and panels.
CWUTREXE
Sample REXX EXEC to invoke CSS online utilities with English messages and panels.
CWUTREXJ
Sample REXX EXEC to invoke CSS online utilities with Japanese messages and panels.
CWVFCLPT
CLIST to invoke the language processor debugging aid.
Preparing for ECC Installation
2-11
CWVFCLSE
CWVFCLSJ
Note: The debugging aid is a diagnostic tool to be used only under the supervision of Compuware Technical Support in the event of a problem related to the language processor.
Sample CLIST to invoke Compuware/VF using English messages and panels.
Sample CLIST to invoke Compuware/VF using Japanese messages and panels.
CWVFDB2
Sample CLIST to activate the File-AID DB2 interface to the Compuware
Viewing Facility.
CWVFREXE
Sample REXX EXEC to invoke Compuware/VF using English messages and panels.
CWVFREXJ
Sample REXX EXEC to invoke Compuware/VF using Japanese messages and panels.
CWVFRXPT
Sample REXX EXEC to invoke the Compuware language processor debugging aid.
Note: The debugging aid is a diagnostic tool to be used only under the supervision of Compuware Technical Support.
CXAADIRX
Abend-AID CWAASDUT DIRX sample JCL.
CXAAEXPO
Abend-AID CWAASDUT EXPORT command sample JCL.
CXAAIMPO
Abend-AID CWAASDUT IMPORT command sample JCL.
CXAAMOVE
Abend-AID CWAASDUT MOVE command sample JCL
CXALLBAA
CXALLBLP
JCL for creating sequential Abend-AID database files.
JCL for creating sequential source listing database files.
CXALLBSD
JCL for creating Abend-AID for CICS sequential transaction databases.
CXALLDAA
JCL for creating Abend-AID shared directories.
CXALLDLP
CXALLDS
CXALLMC
CXALLVAA
CXALLVLP
CXALLVS
JCL for creating Source Listing Shared Directories.
JCL to allocate a sequential DDIO file.
JCL for creating Abend-AID for CICS shared directories.
JCL for creating VSAM Abend-AID database files.
JCL for creating VSAM Source Listing Database files.
JCL to allocate a standard VSAM Abend-AID report or source listing
DDIO file.
JCL for creating Abend-AID for CICS VSAM transaction databases.
CXALLVSD
CXASM
CXASMPRE
CXC
JCL for running the Assembler language postprocessor.
JCL for running the Assembler language preprocessor.
Sample JCL for running the C postprocessor.
2-12
Enterprise Common Components Installation and Customization Guide
CXCAPTUR
CXCFGEXT
Sample JCL for creating a tape from the output of the CSS Problem
Documentation Utility.
Sample JCL to extract a source file from the configuration module in a
CSS load library.
Sample source configuration file.
CXCFGINI
CXCFGSET
CXCIREG
CXCIVSAM
Sample JCL to build a configuration module in a CSS load library, from a source configuration file you create.
Sample JCL to register the Contact Information dataset.
Sample JCL to create the Contact Information dataset.
CXCOBPRE
JCL for running the COBOL language preprocessor.
CXCOB1
JCL for the step to be added after the compile step in your current
COBOL compile and link edit JCL. This is used in order to process the compiler listing through the Compuware language postprocessor.
CXCOB2
JCL to process COBOL compiler listings stored in machine-readable format.
CXCOB99
CXCPRE
CXC2
Sample JCL for running the COBOL postprocessor.
Sample JCL for running the C preprocessor.
Sample JCL to postprocess C compiler listings stored in machinereadable format.
CXDCRADB
JCL to allocate and CREATE a multivolume Abend-AID report database.
CXDCRASD
JCL to allocate and CREATE an Abend-AID shared directory and a multivolume report database.
CXDCRLDB
JCL to allocate and CREATE a multi-volume source listing database.
CXDCRLSD
JCL to allocate and CREATE a source shared directory and a multivolume Source Listing database.
CXDCRTDB
JCL to allocate and CREATE a multi-volume transaction database.
CXDCRTSD
JCL to allocate and CREATE an Abend-AID for CICS shared directory and a multi-volume transaction database.
CXDDSUTL
Sample JCL for running the CWDDSUTL batch file utility.
CXDDUNLP
Sample JCL to execute the CWDDUNLP source extraction utility.
CXDFMAA
JCL to allocate and FORMAT a standard multi-volume Abend-AID report
DDIO file.
CXDFMSL
CXEXPORT
JCL to allocate and FORMAT a standard multi-volume source listing
DDIO file.
Sample JCL for running the CWDDSUTL EXPORT command.
CXFLAG
CXFMTAA
Sample JCL for the CWDDSUTL utility FLAG command.
Sample JCL and CWDDSUTL control statement for formatting Abend-
AID report files.
Preparing for ECC Installation
2-13
CXFMTSL
Sample JCL and CWDDSUTL control statement for formatting a source listing file.
Abend-AID for CICS CWFXSDUT DIRX sample JCL.
CXCFDIRX
CXCFEXPO
CXCFEXTL
Abend-AID for CICS CWFXSDUT EXPORT command sample JCL.
Sample JCL to export a Abend-AID for CICS transaction and a source listing to a single tape.
Abend-AID for CICS CWFXSDUT IMPORT command sample JCL.
CXCFIMPO
CXCFMOVE
Abend-AID for CICS CWFXSDUT MOVE command sample JCL.
CXIMPORT
Sample JCL for running the CWDDSUTL IMPORT command.
CXJCLSEC
CXJCLTRT
CXLPASM
CXLPC
JCL to assemble and link edit the Security Exit program.
JCL to assemble and link edit the custom translation tables.
Sample Assembler language processor options.
Sample C language processor options.
CXLPCOBB
Sample COBOL language processor options (batch programs).
CXLPCOBC
Sample COBOL language processor options (CICS programs).
CXLPDIRX
CXLPEXPO
LP source CWDDLPUT DIRX sample JCL.
LP source CWDDLPUT EXPORT command sample JCL.
CXLPIMPO
LP source CWDDLPUT IMPORT command sample JCL.
CXLPMOVE
LP source CWDDLPUT MOVE command sample JCL.
CXLPPLI
CXLPTFS
Sample PL/I language processor options.
Sample JCL to run SMPE LIST on CSS Target/Distribution zones.
CXLZAPS
Sample JCL to list the PTFs and APARs on a CSS load library
CXMODMAP
Sample JCL member to map the CSECTs in a load module.
CXOTFPRE
CXOTFPST
Sample CLIST stub for preprocessing exit for OTF
Sample CLIST stub for postprocessing exit for OTF
CXPDDSU
CXPLI
CXPLIPRE
CXPLI2
CXPRCTL
CXPRINT
CXRELS
Sample JCL to print a listing or report from a DDIO file.
JCL for running the PL/I language postprocessor.
JCL for running the PL/I language preprocessor.
JCL to postprocess PL/I compiler listings stored in machine-readable format.
IEBPTPCH control statements for job CXPRINT.
JCL to print the entire CSS installation library.
PTF/APAR tracking module. Do not modify this member.
2-14
Enterprise Common Components Installation and Customization Guide
CXR00003
CXSPRE01
CXSPST01
CXTUTOR
CXUECEXT
CXUECIN2
Sample Tutorial main menu.
Sample Skeleton for on-the-fly preprocessing.
Sample Skeleton for on-the-fly postprocessing.
Alternate Sample Tutorial main panel.
Sample CLIST for the Compile Facility JOB card exit
REXX EXEC used to invoke the Compile Information installation screens
DDIODAYS
DDIODAYJ
REXX utility to delete DDIO file members by age.
Sample JCL for running the DDIODAYS REXX utility. This utility deletes
DDIO file members by age.
File-AID DB2 Interface CLIST.
FDXTRN01
GRSRNLXX
P@CPRE01
P@CPST01
P@HPRE01
Sample GRS qname inclusion RNL.
Sample panel for preprocessing exit for on the fly.
Sample panel for postprocessing exit for on the fly.
Sample Help panel for preprocessing exit for on-the-fly processing.
P@HPST01
ATSOECLP
CSPFINIT
CSSTPCFG
Sample Help panel for postprocessing exit for on-the-fly processing.
Sample TSO logon procedure for Xpediter/TSO via Mainframe Common
Components.
Sample JCL to create and initialize the Compuware Shared Profile dataset.
Sample Mainframe Common Components TP configuration file member.
CXCFGBLD
Sample JCL to create the Mainframe Common Components configuration file dataset.
CXTPDEF
Sample HCI configuration parameters to be inserted into an existing
HCI configuration.
CXTP01
HCICFG
Sample HCI PARMLIB member for the Mainframe Common
Components TP.
Sample JCL and macros that define a total HCI configuration for the
Mainframe Common Components TP (use with a newly installed or copied HCI).
HCIJCL
HCIJOURN
HCILOAD
HCIPARM
Sample HCI start-up JCL.
Sample JCL to create the HCI journals.
Sample JCL to create the HCI configuration load library.
Sample JCL to create the HCI PARMLIB library and member.
Preparing for ECC Installation
2-15
LMS Installation Considerations
This section describes considerations for installing and customizing LMS.
APF Authorization
Following IBM system integrity guidelines, Compuware requires that your LMS load library be APF-authorized. You must provide an APF-authorized load library into which you place the modules for LMSINIT since all load modules for LMSINIT must reside in an
APF-authorized load library.
Execution Sequence
In order to ensure availability of Compuware products with LMS-controlled access, the
LMS runtime environment must be established before any of those products are initialized. For this reason, Compuware strongly recommends that you institute an MVS start-up procedure based on the sample proc provided. It should run automatically as part of IPL and IML processing prior to any procs utilized by other Compuware products.
It may be necessary to consult your site’s MVS system programmer.
The License Management System Functions
The License Management System has three basic functions.
License Management Administration
You will create and maintain your License File using the License Administration Utility
(LAU) installed with your License Management Software. Your License File is used as the source from which Compuware products will validate access for your site. When you receive License Certificates for Compuware products, your organization’s License
Administrator must use the LAU to import the License Certificates into the License File.
Additional features of the LAU assist in the maintenance of your License Files. In addition to browsing the License Certificates in your License File, you may run a number of administrative reports from the LAU. These reports will reveal the contents of your
License File, from a number of perspectives, allowing you to determine the state of the
License Certificate for any particular Compuware product release.
Depending on the requirements of your organization, you may have more than one
License File. Each License File can be centrally administered from the License
Administration Utility.
In addition to using the LAU to administer licenses in individual license files, an optional feature called the Centralized Licensing Facility (CLF) can be used to manage your licensing environment from a single z/OS system regardless of where your production or test LPARs reside. Please see the License Management System User/Reference Guide—Centralized
Licensing Facility for more information about CLF.
Establishing the Runtime LMS Environment
You will use the License Files created and maintained by the License Administration
Utility as input to a program that establishes your Compuware LMS runtime environment. This program is named LMSINIT. LMSINIT is the License Management
System program that reads the License File
1
and constructs the License Cache and
License Management System subsystem against which Compuware product runtime license access requests are later made.
1. LMSINIT can read more than one License File if you are an organization that administers Compuware product access for more than one Compuware customer.
2-16
Enterprise Common Components Installation and Customization Guide
Important: You must re-establish your runtime License Management System environment at each IPL, and whenever you have an update to your License File, the update must be made available to your z/OS systems. At IPL startup, LMSINIT must be completed before starting up any Compuware product.
Validating Product Access Requests During Product Use
Your access to your Compuware products will be validated when you use your
Compuware products. The Compuware product will make a request of the License
Management System to determine if your site has a valid License Certificate for the product release. The requests are made by the product at various times during its execution depending on the product’s needs. The Compuware product will access the
LMS subsystem established, request License File information and act upon the information. If the License Certificate information is valid, users will proceed with their use of the product without disruption. Any abnormal License Management event detected will be reported to the product’s user and may optionally be reported by e-mail to your organization’s License Administrator. The disposition and frequency of the reporting of these events can be controlled by the customer using the "Message
Suppression and Distribution" feature of LMS. See the License Management System
User/Reference Guide—Centralized Licensing Facility for more information about this feature.
Optionally, these events may also be recorded in SMF Logging.
Note: LMSINIT can read more than one License File if you are an organization that administers Compuware product access for more than one Compuware customer.
HCI Installation Considerations
This section describes considerations for installing the Host Communications Interface which is a requirement for Distributed Viewing Support and Abend-AID for CICS.
APF Authorization
The HCI component library (COMPWARE.MLHCnnn.SLHCAUTH) must be APFauthorized. This library is used in the server region for Abend-AID Distributed Viewing
Support and Abend-AID for CICS (with or without DVS) as well as functions for other
Compuware products. See Table 2-1 on page 2-1 for the specific products.
TSO Logon PROCs
If you are utilizing Abend-AID Distributed Viewing Support via the Compuware Viewing
Facility, you should update the CWVFCLSE, CWVFCLSJ, CWVFREXE, and CWVFREXJ members to add the HCI library to the ISPLLIB concatenations
(COMPWARE.MLHCnnn.SLHCLOAD). It may also be added to your TSO logon PROC or
added to the link list. For more information, see “Step 5. Activate Compuware ISPF
Dialogs (Required)” on page 5-15.
3-1
Chapter 3.
Receive From Network (RFN) Installation
Notes:
1. If you received the Compuware Shared Services (CSS), License Management System
(LMS), or Host Communications Interface (HCI) product files using the Receive From
Network (RFN) installation procedures, continue with this chapter.
2. If you received the product files using the GUI interface (media browser), continue
with Appendix A, “SMP/E Installation Using GUI Interface”.
This chapter describes how to use the Compuware Receive From Network (RFN) installation procedures to upload the product files and execute the SMP/E installation jobs.
Installation Procedures
In response to customer requests, Compuware has added Receive From Network (RFN) to its product delivery and installation methods. The RFN process enables you to receive the product directly to your z/OS environment and install it using System Modification
Program Extended (SMP/E).
After you select a licensed product from Compuware’s online ordering system, you receive an e-mail message containing sample JCL for creating the SMP/E Global Zone and performing the RFN job. It may also contain a link for downloading any PC-based products that may have been ordered at the same time.
The complete RFN installation for Enterprise Common Components Release 3.2 consists of the following three product components:
• Compuware Shared Services (CSS) Release 9.0
• License Management System (LMS) Release 4.0
• Host Communications Interface (HCI) Release 3.0 Revision 9
Depending on the requirements at your site, you can install any or all of the above three components for which you are licensed. However, with the RFN product delivery process, you can install only one at a time:
• To continue with the RFN installation procedures for CSS, see “Compuware Shared
• To install LMS using RFN installation, continue with “License Management System” on page 3-16.
• To install HCI using RFN installation, continue with “Host Communications
Compuware Shared Services
The following steps provide a checklist for installing Compuware Shared Services.
Part 1: Initialize Installation Environment
1. Create Global Zone CSI
3-2
Enterprise Common Components Installation and Customization Guide
2. Receive From Network
3. Copy SMP/E Installation Dialog from z/OS UNIX to z/OS
Part 2: Customize Installation JCL with ISPF
1. Make Note of HLQ, Global Zone CSI, and Installation File Name
2. Select Installation Components
3. Specify Installation Environment Information
4. Specify SMS Parameters
5. Specify Global CSI Dataset Name
6. Specify job card Information
7. Specify SMP/E High-Level Qualifiers
8. Specify Target and Distribution Zones
9. Verify Installation Information
10. Process the JCL.
Part 3: Install Compuware Shared Services with SMP/E
1. Allocate Libraries and SMP/E Datasets
2. Initialize the Target and Distribution Zone CSIs
3. Review HOLDDATA
4. Apply the Base Code and Cumulative Maintenance to the Target Libraries
5. Accept the Base Code to the Distribution Libraries
Part 4: Configure Compuware Shared Services
Before continuing with the installation steps, be sure to read Chapter 2, “Preparing for
ECC Installation” to determine the considerations that are specific to your needs.
Part 1: Initialize Installation Environment
Step 1. Create Global Zone CSI
A valid SMP/E Global Zone CSI configured for Compuware software is required. If you need to create an SMP/E Global Zone CSI, you can use the sample JCL provided in the file create_smpe_global.txt. Follow the instructions in the comments of the sample JCL to customize the batch job, then submit it to create an SMP/E Global Zone CSI.
Step 2. Receive From Network
Notes:
1. If your order contained multiple products, this step may have already been performed. This step is only required once per order because the smpe_receive job receives everything that was ordered into the specified Global Zone.
2. Ensure enough space has been allocated to perform the Receive From Network for your order.
The most common Receive From Network installation is directly to the mainframe, but not all sites can.
• If you are able to do a Receive From Network directly to your mainframe, you can use the sample JCL attached to the product order e-mail in the file named smpe_receive.txt to facilitate an SMP/E Receive From Network. Follow the instructions in the comments of the sample JCL to customize the batch job, then submit it to perform the RECEIVE. Note that input within this job is case sensitive.
Receive From Network (RFN) Installation
3-3
• If you are unable to do a Receive From Network directly to your mainframe, follow
the instructions in “Tar File SMP/E Receive” on page 3-45 before proceeding. This
section is applicable only if you are not performing an SMP/E Receive From Network directly to your mainframe.
Step 3. Copy SMP/E Installation Dialog from z/OS UNIX to z/OS
Compuware provides an ISPF SMP/E installation dialog in one of the z/OS UNIX System
Services files created by the Receive From Network batch job. Customize and submit the
JCL below to copy that install file to your z/OS system.
Figure 3-1. Sample JCL to Copy Installation Dialog File
//jobname JOB (account),'programmer-name',NOTIFY=&SYSUID,
// MSGLEVEL=(1,1),MSGCLASS=?,CLASS=?,REGION=0M
//*********************************************************************
//* This job will copy the install file to a dataset that will *
//* be customized to complete the SMP/E install. *
//* *
//* @@@@@> INPUT WITHIN THIS JOB IS CaSe sENsiTivE. <@@@@@@ *
//* *
//* NOTES: *
//* 1 - Update the jobcard as required. (REGION=0M is recommended.) *
//* 2 - The PATH='/temp/nts/#######/SMPRELF' on the SMPDIR DD must *
//* point to the directory that contains the install file. *
//* Change the '/temp/nts' portion to what was used when you *
//* customized the PATH= variable on the SMPNTS DD in the *
//* Receive From Network JCL. Change the ####### to the *
//* id= number located on the PACKAGE statement in the Receive *
//* From Network JCL. *
//* 3 - Change ???????? to the SMP/E dataset prefix you used when *
//* you customized the Receive From Network JCL. This should be *
//* the same as the dataset name prefix used for your SMP/E *
//* Global CSI. *
//* 4 - Examine the name= value. The F0 qualifier references the *
//* English version of the installation dialog. For the Japanese *
//* version of the dialog, change the F0 qualifier to F99. *
//*********************************************************************
//SMPER1 EXEC PGM=GIMUNZIP,REGION=0M
//SMPDIR DD PATHDISP=KEEP,PATH='/temp/nts/#######/SMPRELF'
//SMPOUT DD SYSOUT=*
//SYSPRINT DD SYSOUT=*
//SYSUT3 DD UNIT=SYSALLDA,SPACE=(6160,(0230,0760))
//SYSUT4 DD UNIT=SYSALLDA,SPACE=(6160,(0230,0760))
//SYSIN DD *
<GIMUNZIP>
<ARCHDEF
name="IS.PROD.CX.V090000.CPWR.MLCX900.F0.pax.Z"
replace="YES"
newname="????????.MLCX900.INS">
</ARCHDEF>
</GIMUNZIP>
//
Part 2: Customize Installation JCL with ISPF
The ISPF Installation JCL Customization Facility uses screens to gather your installation information. It then uses that information to build the jobs needed to complete the
SMP/E installation.
Step 1. Make Note of HLQ, Global Zone CSI, and Installation File Name
Note: To prevent possible conflicts, Compuware strongly recommends that all
Compuware products and components distributed via SMP/E share a single
Global zone reserved solely for Compuware products. Target and distribution
zones cannot be shared.
3-4
Enterprise Common Components Installation and Customization Guide
The installation process utilizes System Modification Program Extended (SMP/E). For more information about this type of installation, consult the IBM SMP/E Reference or the
IBM SMP/E User’s Guide.
In using Receive from Network (RFN) to receive and install this product, the following steps should have already been performed:
1. Using JCL provided with the order of this product, you should have allocated and initialized an SMP/E Global Zone Consolidated Software Inventory (CSI) that will be used during this install. Optionally, you may have had an SMP/E Global Zone CSI already prepared for Compuware products.
Make a note of the High-Level-Qualifier (HLQ) you specified when creating the CSI:
__________________________________________________________________________
2. Make a note of the full Global Zone CSI name:
__________________________________________________________________________
3. Using JCL provided with the order of this product, you should have performed an
SMP/E Receive from Network for the product(s) ordered. The Installation file was
copied in “Step 3. Copy SMP/E Installation Dialog from z/OS UNIX to z/OS” on page
After running the job, make a note of the installation file name:
__________________________________________________________________________
Step 2. Select Installation Components
The ISPF Installation JCL Customization Facility uses screens to gather your installation information. It then uses that information to build the jobs needed to perform the SMP/E installation.
Notes:
1. The Installation JCL Customization Facility uses ISPF and REXX to generate customized jobstreams and store them in the Installation PDS.
2. Slight variations in the following procedure may exist depending on the format in which you received the product.
Begin the process of installing products using the ISPF Installation JCL Customization
Facility as follows:
1. Invoke the installation facility for the Compuware Shared Services product by entering the TSO EXECUTE command with the dataset name of the installation library followed by $$ECINST. For example:
TSO EX 'hlq.MLCX900.INS($$ECINST)' where hlq is the high-level qualifier you entered when transferring files to the mainframe.
The SMP/E Installation JCL Customization Facility screen (Figure 3-2 on page 3-5) is
displayed.
Receive From Network (RFN) Installation
3-5
Figure 3-2. Selecting Components to Install
Compuware Enterprise Common Components Release 3.2
SMP/E Installation JCL Customization Facility
Command ==>
Place an "S" by one or more of the following components to select that
component for Installation JCL Customization.
To deselect a component, delete the "S"
_ Compuware Shared Services 9.0
Press PF1 for help, END to exit.
2. Type an S to the left of each component you want to install.
3. Press Enter. To indicate your choices, the word SELECTED will be displayed in the
Status column next to each component chosen.
4. To modify a selection, add or delete the S to the left of the component.
5. When you are satisfied with your selections, press Enter again to start the JCL
customization process. The screen shown in Figure 3-3 is displayed.
Step 3. Specify Installation Environment Information
Note: Depending on your installation choices, you may not see all of the screens documented herein.
Figure 3-3. Installation Environment Screen
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services
Please enter the following parameters.
Do you want to enter SMS parameters? NO
DASD Unit: SYSDA
DASD Volser (optional):
SMP/E Work Unit: SYSDA
DASD DSN High Level Qualifier
GLOBAL SMP/E dataset High-level Qualifier: COMPWARE.GLOBAL
This HLQ must match the value in the Receive From Network job.
Press Enter to continue, PF1 for help, or END to return to previous panel.
3-6
Enterprise Common Components Installation and Customization Guide
This screen prompts you to enter information about the installation environment. Notice that the names of the components selected for installation are listed below the
Command prompt. Those names will remain there during the rest of this procedure.
1. Specify installation information as follows:
Do you want to enter SMS parameters?
If you specify YES in the SMS Parameters field, you will be prompted to enter SMS
(Storage Management Subsystem) parameters on the next screen. Depending on your site’s SMS installation options, default SMS parameters may be supplied when datasets are being allocated during execution of the job. If so, or if you do not want to specify SMS parameters, enter NO. Otherwise, enter YES to supply or override the SMS parameters. The default value is NO.
DASD unit
Enter a valid DASD unit name. The value of this field will be used in the UNIT= parameter of the DD statements that allocate non-VSAM libraries and datasets.
The default value is SYSDA.
DASD volser
This field is optional. If a volume is specified, SMP/E will use it as the target for library and dataset allocation.
SMP/E work unit
Enter the name of a DASD unit to use for allocating SMP/E work files. The default value is SYSDA.
DASD DSN High Level Qualifier
Enter the High-level-qualifier of the datasets created by the download procedure.
Global SMP/E dataset high-level qualifier
The HLQ name can be found in the notes you made in “Step 1. Make Note of
HLQ, Global Zone CSI, and Installation File Name” on page 3-3.
2. Press Enter to continue.
Step 4. Specify SMS Parameters
If, in the previous step, you specified NO in the SMS Parameters field, you can skip this step.
The screen shown in Figure 3-4 on page 3-7 was displayed when you pressed Enter in the
previous step.
Receive From Network (RFN) Installation
3-7
Figure 3-4. Specifying SMS Parameters
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services
Enter any or all of the following SMS parameters.
Data Class: dataclas
Storage Class: storclas
Management Class: mgmtclas
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the data class, storage class, and/or management class parameters for the SMS operating environment as follows:
Data Class
Specify the eight-character data class name for SMS.
Storage Class
Specify the eight-character storage class name for SMS.
Management Class
Specify the eight-character management class name for SMS.
Note: Installation defaults are not displayed on this screen. They will be applied during execution of the SMP/E jobstream generated by this procedure. If your site does not supply defaults or you want to override the supplied defaults, enter the desired SMS parameters on this screen.
2. Press Enter to continue.
Step 5. Specify Global CSI Dataset Name
The screen shown in Figure 3-5 on page 3-8 was displayed when you pressed Enter in the
previous step.
3-8
Enterprise Common Components Installation and Customization Guide
Figure 3-5. Specifying Global CSI Dataset Name
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services
The following dataset name will be used for the Global CSI:
COMPWARE.GLOBAL.CSI
If this is not the Global CSI used during the Receive From Network job,
enter the correct Global CSI DSN.
The dataset currently does not exist.
Press Enter to continue, PF1 for help, or END to return to previous panel.
Enter the DSN for the existing global CSI as follows:
1. Verify that the global CSI dataset name is correct.
2. Press Enter.
Step 6. Specify Job Card Information
The screen shown in Figure 3-6 was displayed when you pressed Enter in the previous
step. It prompts you for job card information.
Figure 3-6. Entering Job Card Information
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services
Enter Job Card Information:
//$$$$$$$$ JOB ('ACCT'),'USER NAME',
// CLASS=?,MSGCLASS=?,NOTIFY=PROGRAMMER
//* OPTIONAL JES PARAMETER CARD COULD GO HERE
//*
//*
NOTE: The class selected MUST allow enough CPU time for long running jobs.
Jobs $xxI2APL and $xxI3ACC can easily exceed 5 CPU minutes each.
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the job card information for the ISPF Installation JCL Customization Facility by updating the supplied model job card to follow your site standards. You may enter up to five lines of job information.
Receive From Network (RFN) Installation
3-9
The installation facility will set the $$$$$$$$ value equal to the member name of each job created. You also have the option of specifying the job name using the format xxxxxxx$ or xxxxxxxx, where the x’s are whatever name you choose. If you set it to xxxxxxx$, the installation facility will set the job name for each job to xxxxxxx and append a number to it. A letter will be appended for jobs 10 and above. If you set it to xxxxxxxx, the installation facility will use the specified name for all jobs created.
Note: The job class specified must allow enough CPU time for long-running jobs.
2. Press Enter to continue.
Step 7. Specify SMP/E High-Level Qualifiers
The screen shown in Figure 3-7 was displayed when you pressed Enter in the previous
step. It prompts you for the SMP/E high-level qualifiers of the components previously selected for installation.
Figure 3-7. Specifying SMP/E High-Level Qualifiers
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services
Enter the following information:
Compuware Shared Services
SMP/E Dataset High-level Qualifier: COMPWARE.MLCXnnn
Press Enter to continue, PF1 for help, or END to return to previous panel.
Note: If a high-level qualifier is longer than 28 characters, the installation facility is not able to generate a default dataset name for the target and distribution zones. You can either change the high-level qualifier entered, or manually modify the zone dataset names to valid lengths.
1. Specify the high-level qualifiers as applicable for your installation as follows:
Component-Specific SMP/E Dataset High-level Qualifier
Enter a value to be used in generating names of component-specific datasets, including target and distribution zone CSIs, and their respective non-SMP/E target and distribution libraries. The value entered cannot exceed 28 characters.
2. Press Enter.
Step 8. Specify Target and Distribution Zones
The screen shown in Figure 3-8 on page 3-10 is an example of what was displayed when
you pressed Enter in the previous step.
3-10
Enterprise Common Components Installation and Customization Guide
Figure 3-8. Specifying Target and Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services
Enter the following information for Compuware Shared Services
Distribution Zone Name: LCXnnnD
DZone CSI_Dataset Name: COMPWARE.MLCXnnn.DZONE.CSI
DZone CSI currently does not exist
Target Zone Name: LCXnnnT
TZone CSI Dataset Name: COMPWARE.MLCXnnn.TZONE.CSI
TZone CSI currently does not exist
Japanese Language Support? NO
Modify detail value for Component datasets Yes/No/Reset? N
Default values are being used
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the target and distribution zone information as follows:
Distribution Zone Name
Specifies the name of the SMP/E distribution zone used by the product to be installed. The name you specify must be unique within the global zone. The default is LCXnnnD.
DZone CSI Dataset Name
Specifies the dataset name of the SMP/E distribution zone used by the product to be installed.
DZone CSI currently exists/does not exist
Indicates whether the distribution zone CSI dataset exists.
Target Zone Name
Specifies the name of the SMP/E target zone used by the product to be installed.
The name you specify must be unique within the global zone. The default is
LCXnnnT.
TZone CSI Dataset Name
Specifies the dataset name of the SMP/E target zone used by the product to be installed.
TZone CSI currently exists/does not exist
Indicates whether the target zone CSI dataset exists.
Japanese Language Support
CSS can allocate message and panel libraries to display Japanese language characters rather than English. Specify YES to allocate and install the Japanese language message and panel libraries. Specify NO to bypass allocating these libraries.
Modify detail value for Component datasets Yes/No/Reset? N
Default values are being used.
Note: If either the Target or Distribution CSI's already exist, the following screen will display.
Receive From Network (RFN) Installation
3-11
Figure 3-9. Installing into Pre-existing Target/Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility - Tutorial
CAUTION. The CSI(s) for either or both the Target and Distribution Zones
already exist. If you are installing into an existing set of Target and
Distribution Zones, there is a possibility of destroying data in or related
to the existing Zones.
Compuware strongly suggests you install components into new Zones.
If you try to install a component into the same Zones in a pre-existing CSI,
the SMPMCS for ECC is designed to delete previous releases of that component.
To install a new release of a component into a CSI without deleting previous
releases, you must install using a different Zone Name (default).
2. You can modify or enter detail values for Component datasets by specifying Y (yes).
3. To reset any overridden detail values to default, specify R (reset).
4. Press Enter.
Step 9. Verify Installation Information
When you pressed Enter in the previous step, the first of a series of confirmation screens was displayed. On each confirmation screen you have the following choices.
• To accept the information on the screen, press Enter.
• To correct a particular parameter, press End to return to the associated entry screen.
After you accept the information on each of the confirmation screens, the installation process will continue.
Step 10. Process the JCL
The screen shown in Figure 3-10 was displayed when you pressed Enter the final time in
the previous step.
Figure 3-10. Confirming JCL Processing
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Processing Verification Screen
Command ==>
Customizing: Compuware Shared Services
Press Enter to begin customizing the JCL.
3-12
Enterprise Common Components Installation and Customization Guide
1. Press Enter to start the processing that builds customized JCL members or press End to cancel the installation.
When you press Enter, the progress of the JCL customization process is displayed in a scrollable area on the screen. You can scroll up or down to view the list of jobs and the members generated.
2. After the installation JCL has been created, press End. A screen is displayed informing
you that a parameter report has been generated (Figure 3-11). This report details the
JCL created and lists the parameters and execution information used during installation.
Figure 3-11. Report Member Detailing JCL Processing
Enterprise Common Components
SMP/E Installation JCL Customization Facility
The following PDS member contains a report of all parameters used during
customization and a log of all JCL members created:
hlq.MLCXnnn.INS($$CSRPT)
Press Enter to browse the report, END to exit.
3. If you want to browse the report at this time, press Enter. You can also examine the report later by accessing the installation library report member shown on this screen.
4. Press End. The screen first displayed in Figure 3-2 on page 3-5 will be redisplayed,
showing a status of COMPLETE for each component (Figure 3-12).
Figure 3-12. Displaying Completion Status
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Place an "S" by one or more of the following components to select that
component for Installation JCL Customization.
To deselect a component, delete the "S"
_ Compware Common Components 09.00.00 COMPLETE
Press PF1 for help, END to exit.
5. Press End. The screen shown in Figure 3-13 on page 3-13 will be displayed instructing
you to refer to the product installation guides to complete the installation process.
Receive From Network (RFN) Installation
3-13
Figure 3-13. Final JCL Customization panel
Command ==>
Place an "S" by one or more of the following components to select that
component for Installation JCL Customization.
To deselect a component, delete the "S"
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Enterprise Common Components
SMP/E Installation JCL Customization Facility return to the ECC Installation and Customization Guide.
Press END to exit.
Note: To complete the installation of the selected component(s),
S Compware Common Components 09.00.00 COMPLETE
6. The processing of the ISPF Installation JCL Customization Facility is now finished.
Press End to exit.
Note: Compuware recommends you maintain availability to your customized install library. Otherwise, it may be necessary to unload and recustomize the install library from product or maintenance media to perform future maintenance.
Part 3: Install Compuware Shared Services with SMP/E
There are six sample jobs for using SMP/E to install Compuware Shared Services.
Installation JCL members are described in the following table.
Table 3-1. Installation JCL Members
Member Function
$CSI0GBA
Unnecessary for a Receive From Network-initiated Install.
$CSI1PRA
$CSI1PRB
Performs the allocation of the zones and related SMP/E datasets.
Initializes the CSIs with the required entries.
$CSI2RCV
$CSI3APL
$CSI4ACC
Unnecessary for a Receive From Network-initiated Install.
Applies the base code and maintenance.
Accepts the base code.
Note: Except where otherwise noted, the return code from all jobs should be zero.
Step 1. Allocate Libraries and SMP/E Datasets
This step allocates target and distribution zone CSIs as well as product-specific SMP/E datasets. These datasets include the product-specific load libraries.
The installation facility has created a job called $CSI1PRA that allocates the required libraries and datasets.
Note: The space allocations used are based on 3390 DASD. If you use 3380 DASD, you may decide to change the BLKSIZE for the load library to 6356 for a better blocking factor.
1. Review the job $CSI1PRA for any necessary changes.
3-14
Enterprise Common Components Installation and Customization Guide
2. Submit the job to start the allocation process.
Step 2. Initialize the Target and Distribution Zone CSIs
This step initializes the Compuware Shared Services target and distribution zone CSIs.
The installation facility has created a job called $CSI1PRB that performs the initialization.
1. Review the job $CSI1PRB for any necessary changes.
Note: Before you submit this job, make sure the job submitted in the previous step has completed.
2. Submit the job to start the initialization process. This job uses REP statements rather than ADD statements to simplify rerunning the job. It is normal to receive a return code of 4 with the following messages:
GIM56501W The aaaaaa subentry was added rather than replaced
because it did not exist.
GIM27701W aaaaaaaa ENTRY bbbbbbbbbbbbbbbbb does not exist. the replace
operation has been changed to an add.
Otherwise, the return code should be 0.
Step 3. Review HOLDDATA
At times, installing base code and maintenance requires additional actions that must be performed after a PTF(s) is applied. In these cases, the PTF is identified as an exception with:
++HOLD and the HOLDDATA contains information on the additional actions you must perform to completely implement the change. The HOLDDATA can be found in the SMPRPT output from the RFN job.
If the SMPRPT is not available, you can execute a batch SMPE job against the Global Zone with the following commands to display the HOLDDATA:
SET BOUNDARY(GLOBAL).
LIST HOLDDATA FORFMID(MLCXnnn).
If the Japanese FMID was installed, add NLCXnnn) to the FORFMID() parm.
CAUTION:
It is very important that you perform any HOLDDATA action. Failure to do so can cause unpredictable results, including incorrect data and abends. It is possible that the installation does not have any hold actions.
Step 4. Apply the Base Code and Cumulative Maintenance to the Target
Libraries
This step applies the Compuware Shared Services base code and cumulative maintenance to the target zone. The installation facility has created a job called $CSI3APL that performs the apply process.
Receive From Network (RFN) Installation
3-15
CAUTION:
Be sure to run $CSI3APL in a job class suitable for long-running batch jobs.
Note: The default control statements apply the base FMID and all cumulative maintenance. However, you may want to run an APPLY CHECK before applying the software.
1. Review the job $CSI3APL for any necessary changes.
2. Submit the job to start the apply process.
When the base code is applied, it is normal to receive a return code of 4 with messages similar to the following:
GIM43401W MODULE ADSIM100 IN SYSMOD MLXTnnn
was not installed in any target zone.
GIM43401W MODULE ADSIM101 IN SYSMOD MLXTnnn
was not installed in any target zone.
GIM43401W MODULE ADSIM102 IN SYSMOD MLXTnnn
was not installed in any target zone.
Note: An APPLY may end with a non-zero return code, even though the APPLY CHECK ended with RC=0. This is because the APPLY may invoke external utilities, such as IEBCOPY or the linkage editor, while the APPLY CHECK only checks the SMP/E environment. A return code of 4 is expected from the linkage editor with messages similar to the following:
IEW2454W 9203 SYMBOL module-name UNRESOLVED.
NO AUTOCALL (NCAL) SPECIFIED.
Step 5. Accept the Base Code to the Distribution Libraries
This step accepts the Compuware Shared Services base code to the distribution libraries.
The installation facility has created a job called $CSI4ACC that accepts the base code into the distribution libraries.
CAUTION:
Be sure to run $CSI4ACC in a job class suitable for long-running batch jobs.
Note: The default control statements accept the base FMID. However, you may want to run an ACCEPT CHECK before accepting the software.
1. Review the job $CSI4ACC for any necessary changes.
2. Submit the job to start the accept process.
Note: An ACCEPT may end with a non-zero return code, even though the ACCEPT
CHECK ended with RC=0. This is because the ACCEPT may invoke external utilities, such as IEBCOPY or the linkage editor, while the ACCEPT CHECK only checks the SMP/E environment.
Part 4: Configure Compuware Shared Services
After the installation has been completed, continue with the procedures in Chapter 5,
3-16
Enterprise Common Components Installation and Customization Guide
License Management System
If you’re installing License Management System using the Receive From Network (RFN)
procedures, continue with “Installation Procedures” below.
Installation Procedures
The following steps provide a checklist for installing License Management System.
Part 1: Initialize Installation Environment
1. Create Global Zone CSI
2. Receive From Network
3. Copy SMP/E Installation Dialog File from z/OS UNIX to z/OS
Part 2: Customize Installation JCL with ISPF
1. Make Note of HLQ, Global Zone CSI, and Installation File Name
2. Select Installation Components
3. Specify Installation Environment Information
4. Specify SMS Parameters
5. Specify Global CSI Dataset Name
6. Specify job card Information
7. Specify SMP/E High-Level Qualifiers
8. Specify Target and Distribution Zones
9. Verify Installation Information
10. Process the JCL.
Part 3: Install License Management System with SMP/E
1. Allocate Libraries and SMP/E Datasets
2. Initialize the Target and Distribution Zone CSIs
3. Review HOLDDATA
4. Apply the Base Code and Cumulative Maintenance to the Target Libraries
5. Accept the Base Code to the Distribution Libraries
Part 4: Configure License Management System
Before continuing with the installation steps, be sure to read Chapter 2, “Preparing for
ECC Installation” to determine the considerations that are specific to your needs.
Part 1: Initialize Installation Environment
Step 1. Create Global Zone CSI
A valid SMP/E Global Zone CSI configured for Compuware software is required. If you need to create an SMP/E Global Zone CSI, you can use the sample JCL provided in the file create_smpe_global.txt
. Follow the instructions in the comments of the sample JCL to customize the batch job, then submit it to create an SMP/E Global Zone CSI.
Receive From Network (RFN) Installation
3-17
Step 2. Receive From Network
Notes:
1. If your order contained multiple products, this step may have already been performed. This step is only required once per order because the smpe_receive job receives everything that was ordered into the specified Global Zone.
2. Ensure enough space has been allocated to perform the Receive From Network for your order.
The most common Receive From Network installation is directly to the mainframe, but not all sites can.
• If you are able to do a Receive From Network directly to your mainframe, you can use the sample JCL attached to the product order e-mail in the file named smpe_receive.txt to facilitate an SMP/E Receive From Network. Follow the instructions in the comments of the sample JCL to customize the batch job, then submit it to perform the RECEIVE. Note that input within this job is case sensitive.
• If you are unable to do a Receive From Network directly to your mainframe, follow
the instructions in “Tar File SMP/E Receive” on page 3-45 before proceeding. This
section is applicable only if you are not performing an SMP/E Receive From Network directly to your mainframe.
Step 3. Copy SMP/E Installation Dialog File from z/OS UNIX to z/OS
Compuware provides an ISPF SMP/E installation dialog in one of the z/OS UNIX System
Services files created by the Receive From Network batch job. Customize and submit the
JCL below to copy that install file to your z/OS system.
Figure 3-14. Sample JCL to Copy Installation Dialog File
//jobname JOB (account),'programmer-name',NOTIFY=&SYSUID,
// MSGLEVEL=(1,1),MSGCLASS=?,CLASS=?,REGION=0M
//*********************************************************************
//* This job will copy the install file to a dataset that will *
//* be customized to complete the SMP/E install. *
//* *
//* @@@@@> INPUT WITHIN THIS JOB IS CaSe sENsiTivE. <@@@@@@ *
//* *
//* NOTES: *
//* 1 - Update the jobcard as required. (REGION=0M is recommended.) *
//* 2 - The PATH='/temp/nts/#######/SMPRELF' on the SMPDIR DD must *
//* point to the directory that contains the install file. *
//* Change the '/temp/nts' portion to what was used when you *
//* customized the PATH= variable on the SMPNTS DD in the *
//* Receive From Network JCL. Change the ####### to the *
//* id= number located on the PACKAGE statement in the Receive *
//* From Network JCL. *
//* 3 - Change ???????? to the SMP/E dataset prefix you used when *
//* you customized the Receive From Network JCL. This should be *
//* the same as the dataset name prefix used for your SMP/E *
//* Global CSI. *
//* 4 - Examine the name= value. The F0 qualifier references the *
//* English version of the installation dialog. For the Japanese *
//* version of the dialog, change the F0 qualifier to F99. *
//*********************************************************************
//SMPER1 EXEC PGM=GIMUNZIP,REGION=0M
//SMPDIR DD PATHDISP=KEEP,PATH='/temp/nts/#######/SMPRELF'
//SMPOUT DD SYSOUT=*
//SYSPRINT DD SYSOUT=*
//SYSUT3 DD UNIT=SYSALLDA,SPACE=(6160,(0230,0760))
//SYSUT4 DD UNIT=SYSALLDA,SPACE=(6160,(0230,0760))
//SYSIN DD *
<GIMUNZIP>
<ARCHDEF
name="IS.PROD.LM.V040000.CPWR.MLMS400.F0.pax.Z"
replace="YES"
newname="????????.MLMS400.INS">
</ARCHDEF>
</GIMUNZIP>
//
3-18
Enterprise Common Components Installation and Customization Guide
Part 2: Customize Installation JCL with ISPF
The ISPF Installation JCL Customization Facility uses screens to gather your installation information. It then uses that information to build the jobs needed to complete the
SMP/E installation.
Step 1. Make Note of HLQ, Global Zone CSI, and Installation File Name
Note: To prevent possible conflicts, Compuware strongly recommends that all
Compuware products and components distributed via SMP/E share a single
Global zone reserved solely for Compuware products. Target and distribution
zones cannot be shared.
The installation process utilizes System Modification Program Extended (SMP/E). For more information about this type of installation, consult the IBM SMP/E Reference or the
IBM SMP/E User’s Guide.
In using Receive from Network (RFN) to receive and install this product, the following steps should have already been performed:
1. Using JCL provided with the order of this product, you should have allocated and initialized an SMP/E Global Zone Consolidated Software Inventory (CSI) that will be used during this install. Optionally, you may have had an SMP/E Global Zone CSI already prepared for Compuware products.
Make a note of the high-level qualifier (HLQ) you specified when creating the CSI:
__________________________________________________________________________
Make a note of the full Global Zone CSI name:
__________________________________________________________________________
2. Using JCL provided with the order of this product, you should have performed an
SMP/E Receive from Network for the product(s) ordered. The Installation file was
copied in “Step 3. Copy SMP/E Installation Dialog File from z/OS UNIX to z/OS” on page 3-17.
After running the job, make note of the installation file name:
__________________________________________________________________________
Step 2. Select Installation Components
The ISPF Installation JCL Customization Facility uses screens to gather your installation information. It then uses that information to build the jobs needed to perform the SMP/E installation.
Notes:
1. The Installation JCL Customization Facility uses ISPF and REXX to generate customized jobstreams and store them in the Installation PDS.
2. Slight variations in the following procedure may exist depending on the format in which you received the product.
Begin the process of installing products using the ISPF Installation JCL Customization
Facility as follows:
1. Invoke the installation facility for the Enterprise Common Components product by entering the TSO EXECUTE command with the dataset name of the installation library followed by $$ECINST. For example:
TSO EX 'hlq.MLMS400.INS($$ECINST)'
Receive From Network (RFN) Installation
3-19
where hlq is the high-level qualifier you entered when transferring files to the
mainframe. The exact dataset name can be found in the notes you made from “Step
1. Make Note of HLQ, Global Zone CSI, and Installation File Name” on page 3-18.
The SMP/E Installation JCL Customization Facility screen (Figure 3-15) is displayed.
Figure 3-15. Selecting Components to Install
Compuware Enterprise Common Components Release 3.2
SMP/E Installation JCL Customization Facility
Command ==>
Place an "S" by one or more of the following components to select that
component for Installation JCL Customization.
To deselect a component, delete the "S"
_ License Management 4.0
Press PF1 for help, END to exit.
2. Type an S to the left of the component to be installed.
3. Press Enter. To indicate your choices, the word SELECTED will be displayed in the
Status column next to each component chosen.
4. To modify a selection, add or delete the S to the left of the component.
5. When you are satisfied with your selections, press Enter again to start the JCL
customization process. The screen shown in Figure 3-16 on page 3-20 is displayed.
Step 3. Specify Installation Environment Information
Note: Depending on your installation choices, you may not see all of the screens documented herein.
3-20
Enterprise Common Components Installation and Customization Guide
Figure 3-16. Installation Environment Screen
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: License Management
Please enter the following parameters.
Do you want to enter SMS parameters? NO
DASD Unit: SYSDA
DASD Volser (optional):
SMP/E Work Unit: SYSDA
DASD DSN High Level Qualifier
GLOBAL SMP/E dataset High-level Qualifier: COMPWARE.GLOBAL
This HLQ must match the value in the Receive From Network job.
Press Enter to continue, PF1 for help, or END to return to previous panel.
This screen prompts you to enter information about the installation environment. Notice that the names of the components selected for installation are listed below the
Command prompt. Those names will remain there during the rest of this procedure.
1. Specify installation information as follows:
Do you want to enter SMS parameters?
If you specify YES in the SMS Parameters field, you will be prompted to enter SMS
(Storage Management Subsystem) parameters on the next screen. Depending on your site’s SMS installation options, default SMS parameters may be supplied when datasets are being allocated during execution of the job. If so, or if you do not want to specify SMS parameters, enter NO. Otherwise, enter YES to supply or override the SMS parameters. The default value is NO.
DASD unit
Enter a valid DASD unit name. The value of this field will be used in the UNIT= parameter of the DD statements that allocate non-VSAM libraries and datasets.
The default value is SYSDA.
DASD volser
This field is optional. If a volume is specified, SMP/E will use it as the target for library and dataset allocation.
SMP/E work unit
Enter the name of a DASD unit to use for allocating SMP/E work files. The default value is SYSDA.
DASD DSN High Level Qualifier
Enter the High-level-qualifier of the datasets created by the download procedure.
Global SMP/E dataset high-level qualifier
The HLQ name can be found in the notes you made from “Step 1. Make Note of
HLQ, Global Zone CSI, and Installation File Name” on page 3-18.
2. Press Enter to continue.
Receive From Network (RFN) Installation
3-21
Step 4. Specify SMS Parameters
If, in the previous step, you specified NO in the SMS Parameters field, you can skip this step.
The screen shown in Figure 3-17 was displayed when you pressed Enter in the previous
step.
Figure 3-17. Specifying SMS Parameters
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: License Management
Enter any or all of the following SMS parameters.
Data Class: dataclas
Storage Class: storclas
Management Class: mgmtclas
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the data class, storage class, and/or management class parameters for the SMS operating environment as follows:
Data Class
Specify the eight-character data class name for SMS.
Storage Class
Specify the eight-character storage class name for SMS.
Management Class
Specify the eight-character management class name for SMS.
Note: Installation defaults are not displayed on this screen. They will be applied during execution of the SMP/E jobstream generated by this procedure. If your site does not supply defaults or you want to override the supplied defaults, enter the desired SMS parameters on this screen.
2. Press Enter to continue.
Step 5. Specify Global CSI Dataset Name
The screen shown in Figure 3-18 on page 3-22 was displayed when you pressed Enter in
the previous step.
3-22
Enterprise Common Components Installation and Customization Guide
Figure 3-18. Specifying Global CSI Dataset Name
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: License Management
The following dataset name will be used for the Global CSI:
COMPWARE.GLOBAL.CSI
If this is not the Global CSI used during the Receive From Network job,
enter the correct Global CSI DSN.
The dataset currently does not exist.
Press Enter to continue, PF1 for help, or END to return to previous panel.
Enter the DSN for the existing global CSI as follows:
1. Verify that the global CSI dataset name is correct. If necessary, change the name to
2. Press Enter.
Step 6. Specify Job Card Information
The screen shown in Figure 3-19 was displayed when you pressed Enter in the previous
step. It prompts you for job card information.
Figure 3-19. Entering Job Card Information
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: License Management System
Enter Job Card Information:
//$$$$$$$$ JOB ('ACCT'),'USER NAME',
// CLASS=?,MSGCLASS=?,NOTIFY=PROGRAMMER
//* OPTIONAL JES PARAMETER CARD COULD GO HERE
//*
//*
NOTE: The class selected MUST allow enough CPU time for long running jobs.
Jobs $xxI2APL and $xxI3ACC can easily exceed 5 CPU minutes each.
Press Enter to continue, PF1 for help, or END to return to previous panel.
Receive From Network (RFN) Installation
3-23
1. Specify the job card information for the ISPF Installation JCL Customization Facility by updating the supplied model job card to follow your site standards. You may enter up to five lines of job information.
The installation facility will set the $$$$$$$$ value equal to the member name of each job created. You also have the option of specifying the job name using the format xxxxxxx$ or xxxxxxxx, where the x’s are whatever name you choose. If you set it to xxxxxxx$, the installation facility will set the job name for each job to xxxxxxx and append a number to it. A letter will be appended for jobs 10 and above. If you set it to xxxxxxxx, the installation facility will use the specified name for all jobs created.
Note: The job class specified must allow enough CPU time for long-running jobs.
2. Press Enter to continue.
Step 7. Specify SMP/E High-Level Qualifiers
The screen shown in Figure 3-20 was displayed when you pressed Enter in the previous
step. It prompts you for the SMP/E high-level qualifiers of the components previously selected for installation.
Figure 3-20. Specifying SMP/E High-Level Qualifiers
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: License Management
Enter the following information:
License Management System
SMP/E Dataset High-level Qualifier: COMPWARE.MLMSnnn
Press Enter to continue, PF1 for help, or END to return to previous panel.
Note: If a high-level qualifier is longer than 28 characters, the installation facility is not able to generate a default dataset name for the target and distribution zones. You can either change the high-level qualifier entered, or manually modify the zone dataset names to valid lengths.
1. Specify the high-level qualifiers as applicable for your installation as follows:
Component-Specific SMP/E Dataset High-level Qualifier
Enter a value to be used in generating names of component-specific datasets, including target and distribution zone CSIs, and their respective non-SMP/E target and distribution libraries. The value entered cannot exceed 28 characters.
2. Press Enter.
3-24
Enterprise Common Components Installation and Customization Guide
Step 8. Specify Target and Distribution Zones
The screen shown in Figure 3-21 is an example of what was displayed when you pressed
Enter in the previous step.
Figure 3-21. Specifying Target and Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: License Management
Enter the following information for License Management System
Distribution Zone Name: LMSnnnD
DZone CSI_Dataset Name: COMPWARE.MLMSnnn.DZONE.CSI
DZone CSI currently does not exist
Target Zone Name: LMSnnnT
TZone CSI Dataset Name: COMPWARE.MLMSnnn.TZONE.CSI
TZone CSI currently does not exist
Japanese Language Support? NO
Modify detail value for Component datasets Yes/No/Reset? N
Default values are being used
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the target and distribution zone information as follows:
Distribution Zone Name
Specifies the name of the SMP/E distribution zone used by the product to be installed. The name you specify must be unique within the global zone. The default is LMSnnnD.
DZone CSI Dataset Name
Specifies the dataset name of the SMP/E distribution zone used by the product to be installed.
DZone CSI currently exists/does not exist
Indicates whether the distribution zone CSI dataset exists.
Target Zone Name
Specifies the name of the SMP/E target zone used by the product to be installed.
The name you specify must be unique within the global zone. The default is
LMSnnnT.
TZone CSI Dataset Name
Specifies the dataset name of the SMP/E target zone used by the product to be installed.
TZone CSI currently exists/does not exist
Indicates whether the target zone CSI dataset exists.
Japanese Language Support
CSS can allocate message and panel libraries to display Japanese language characters rather than English. Specify YES to allocate and install the Japanese language message and panel libraries. Specify NO to bypass allocating these libraries.
Receive From Network (RFN) Installation
3-25
Modify detail value for Component datasets Yes/No/Reset? N
Default values are being used.
Note: If either the Target or Distribution CSI's already exist, the following screen will display.
Figure 3-22. Installing into Pre-existing Target/Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility - Tutorial
CAUTION. The CSI(s) for either or both the Target and Distribution Zones
already exist. If you are installing into an existing set of Target and
Distribution Zones, there is a possibility of destroying data in or related
to the existing Zones.
Compuware strongly suggests you install components into new Zones.
If you try to install a component into the same Zones in a pre-existing CSI,
the SMPMCS for ECC is designed to delete previous releases of that component.
To install a new release of a component into a CSI without deleting previous
releases, you must install using a different Zone Name (default).
2. You can modify or enter detail values for Component datasets by specifying Y (yes).
3. To reset any overridden detail values to default, specify R (reset).
4. Press Enter.
Step 9. Verify Installation Information
When you pressed Enter in the previous step, the first of a series of confirmation screens was displayed. On each confirmation screen you have the following choices.
• To accept the information on the screen, press Enter.
• To correct a particular parameter, press END (PF3) to return to the associated entry screen.
After you accept the information on each of the confirmation screens, the installation process will continue.
Step 10. Process the JCL
The screen shown in Figure 3-23 on page 3-26 was displayed when you pressed Enter the
final time in the previous step.
3-26
Enterprise Common Components Installation and Customization Guide
Figure 3-23. Confirming JCL Processing
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Processing Verification Screen
Command ==>
Customizing: License Management
Press Enter to begin customizing the JCL.
1. Press Enter to start the processing that builds customized JCL members or press END
(PF3) to cancel the installation.
When you press Enter, the progress of the JCL customization process is displayed in a scrollable area on the screen. You can scroll up or down to view the list of jobs and the members generated.
2. After the installation JCL has been created, press END (PF3). A screen is displayed
informing you that a parameter report has been generated (Figure 3-24). This report
details the JCL created and lists the parameters and execution information used during installation.
Figure 3-24. Report Member Detailing JCL Processing
Enterprise Common Components
SMP/E Installation JCL Customization Facility
The following PDS member contains a report of all parameters used during
customization and a log of all JCL members created:
hlq.MLMSnnn.INS($$xxRPT)
Press Enter to browse the report, END to exit.
3. If you want to browse the report at this time, press Enter. You can also examine the report later by accessing the installation library report member shown on this screen.
4. Press END (PF3). The screen first displayed in Figure 3-15 on page 3-19 will be
redisplayed, showing a status of COMPLETE for each component (Figure 3-25 on page 3-27).
Receive From Network (RFN) Installation
3-27
Figure 3-25. Displaying Completion Status
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Place an "S" by one or more of the following components to select that
component for Installation JCL Customization.
To deselect a component, delete the "S"
_ License Management System 04.00.00 COMPLETE
Press PF1 for help, END to exit.
5. Press END (PF3). The screen shown in Figure 3-26 will be displayed instructing you to
refer to the product installation guides to complete the installation process.
Figure 3-26. Final JCL Customization panel
Command ==>
Place an "S" by one or more of the following components to select that
component for Installation JCL Customization.
To deselect a component, delete the "S"
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Enterprise Common Components
SMP/E Installation JCL Customization Facility return to the ECC Installation and Customization Guide.
Press END to exit.
Note: To complete the installation of the selected component(s),
S Compware Common Components 09.00.00 COMPLETE
6. The processing of the ISPF Installation JCL Customization Facility is now finished.
Press END (PF3) to exit.
Note: Compuware recommends you maintain availability to your customized install library. Otherwise, it may be necessary to unload and recustomize the install library from product or maintenance media to perform future maintenance.
Part 3: Install License Management System with SMP/E
There are six sample jobs for using SMP/E to install License Management System. Use the
dataset name found in the notes you made from “Step 1. Make Note of HLQ, Global Zone
CSI, and Installation File Name” on page 3-18.
3-28
Enterprise Common Components Installation and Customization Guide
Installation JCL members are described in the following table.
Table 3-2. Installation JCL Members
Member Function
$LMI0GBA Unnecessary for a Receive From Network-initiated Install.
$LMI1PRA
$LMI1PRB
$LMI2RCV
$LMI3APL
$LMI4ACC
Performs the allocation of the zones and related SMP/E datasets.
Initializes the LMIs with the required entries.
Unnecessary for a Receive From Network-initiated Install.
Applies the base code and maintenance.
Accepts the base code.
Note:
Except where otherwise noted, the return code from all jobs should be zero.
Step 1. Allocate Libraries and SMP/E Datasets
This step allocates target and distribution zone CSIs as well as product-specific SMP/E datasets. These datasets include the product-specific load libraries.
The installation facility has created a job called $LMI1PRA that allocates the required libraries and datasets.
The installation facility has created a job called $LMI1PRA that allocates the required libraries and datasets.
Note:
The space allocations used are based on 3390 DASD. If you use 3380 DASD, you may decide to change the BLKSIZE for the load library to 6356 for a better blocking factor.
1. Review the job $LMI1PRA for any necessary changes.
2. Submit the job to start the allocation process.
Step 2. Initialize the Target and Distribution Zone CSIs
This step initializes the License Management System target and distribution zone LMIs.
The installation facility has created a job called $LMI1PRB that performs the initialization.
1. Review the job $LMI1PRB for any necessary changes.
Note: Before you submit this job, make sure the job submitted in the previous step has completed.
2. Submit the job to start the initialization process. This job uses REP statements rather than ADD statements to simplify rerunning the job. It is normal to receive a return code of 4 with the following messages:
GIM56501W The aaaaaa subentry was added rather than replaced
because it did not exist.
GIM27701W aaaaaaaa ENTRY bbbbbbbbbbbbbbbbb does not exist. the replace
operation has been changed to an add.
Otherwise, the return code should be 0.
Receive From Network (RFN) Installation
3-29
Step 3. Review HOLDDATA
At times, installing base code and maintenance requires additional actions that must be performed after a PTF(s) is applied. In these cases, the PTF is identified as an exception with:
++HOLD and the HOLDDATA contains information on the additional actions you must perform to completely implement the change. The HOLDDATA can be found in the SMPRPT output from the RFN job.
If the SMPRPT is not available, you can execute a batch SMPE job against the Global Zone with the following commands to display the HOLDDATA:
SET BOUNDARY(GLOBAL)
LIST HOLDDATA FORFMID(MLMSnnn)
CAUTION:
It is very important that you perform any HOLDDATA action. Failure to do so can cause unpredictable results, including incorrect data and abends. It is possible that the installation does not have any hold actions.
Step 4. Apply the Base Code and Cumulative Maintenance to the Target
Libraries
This step applies the License Management System base code and cumulative maintenance to the target zone. The installation facility has created a job called $LMI3APL that performs the apply process.
CAUTION:
Be sure to run $LMI3APL in a job class suitable for long-running batch jobs.
Note: The default control statements apply the base FMID and all cumulative maintenance. However, you may want to run an APPLY CHECK before applying the software.
1. Review the job $LMI3APL for any necessary changes.
2. Submit the job to start the apply process.
When the base code is applied, it is normal to receive a return code of 4 with messages similar to the following:
GIM43401W MODULE ADSIM100 IN SYSMOD MLXTnnn
was not installed in any target zone.
GIM43401W MODULE ADSIM101 IN SYSMOD MLXTnnn
was not installed in any target zone.
GIM43401W MODULE ADSIM102 IN SYSMOD MLXTnnn
was not installed in any target zone.
Note: An APPLY may end with a non-zero return code, even though the APPLY CHECK ended with RC=0. This is because the APPLY may invoke external utilities, such as IEBCOPY or the linkage editor, while the APPLY CHECK only checks the SMP/E environment. A return code of 4 is expected from the linkage editor with messages similar to the following:
IEW2454W 9203 SYMBOL module-name UNRESOLVED.
NO AUTOCALL (NCAL) SPECIFIED.
3-30
Enterprise Common Components Installation and Customization Guide
Step 5. Accept the Base Code to the Distribution Libraries
This step accepts the License Management System base code to the distribution libraries.
The installation facility has created a job called $LMI4ACC that accepts the base code into the distribution libraries.
CAUTION:
Be sure to run $LMI4ACC in a job class suitable for long-running batch jobs.
Note: The default control statements accept the base FMID. However, you may want to run an ACCEPT CHECK before accepting the software.
1. Review the job $LMI4ACC for any necessary changes.
2. Submit the job to start the accept process.
Note: An ACCEPT may end with a non-zero return code, even though the ACCEPT
CHECK ended with RC=0. This is because the ACCEPT may invoke external utilities, such as IEBCOPY or the linkage editor, while the ACCEPT CHECK only checks the SMP/E environment.
Part 4: Configure License Management System
After the installation has been completed, continue with the procedures in Chapter 6,
Host Communications Interface
If you’re installing Host Communications Interface using the Receive From Network
(RFN) procedures, continue with “Installation Procedures” below.
Installation Procedures
The following steps provide a checklist for installing Host Communications Interface.
Part 1: Initialize Installation Environment
1. Create Global Zone CSI
2. Receive From Network
3. Copy SMP/E Installation Dialog File from z/OS UNIX to z/OS
Part 2: Customize Installation JCL with ISPF
1. Make Note of HLQ, Global Zone CSI, and Installation File Name
2. Select Installation Components
3. Specify Installation Environment Information
4. Specify SMS Parameters
5. Specify Global CSI Dataset Name
6. Specify job card Information
7. Specify SMP/E High-Level Qualifiers
8. Specify Target and Distribution Zones
9. Verify Installation Information
10. Process the JCL.
Receive From Network (RFN) Installation
3-31
Part 3: Install Host Communications Interface with SMP/E
1. Allocate Libraries and SMP/E Datasets
2. Initialize the Target and Distribution Zone CSIs
3. Review HOLDDATA
4. Apply the Base Code and Cumulative Maintenance to the Target Libraries
5. Accept the Base Code to the Distribution Libraries
Part 4: Configure Host Communications Interface
Before continuing with the installation steps, be sure to read Chapter 2, “Preparing for
ECC Installation” to determine the considerations that are specific to your needs.
Part 1: Initialize Installation Environment
Step 1. Create Global Zone CSI
A valid SMP/E Global Zone CSI configured for Compuware software is required. If you need to create an SMP/E Global Zone CSI, you can use the sample JCL provided in the file create_smpe_global.txt. Follow the instructions in the comments of the sample JCL to customize the batch job, then submit it to create an SMP/E Global Zone CSI.
Step 2. Receive From Network
Notes:
1. If your order contained multiple products, this step may have already been performed. This step is only required once per order because the smpe_receive job receives everything that was ordered into the specified Global Zone.
2. Ensure enough space has been allocated to perform the Receive From Network for your order.
The most common Receive From Network installation is directly to the mainframe, but not all sites can.
• If you are able to do a Receive From Network directly to your mainframe, you can use the sample JCL attached to the product order e-mail in the file named smpe_receive.txt to facilitate an SMP/E Receive From Network. Follow the instructions in the comments of the sample JCL to customize the batch job, then submit it to perform the RECEIVE. Note that input within this job is case sensitive.
• If you are unable to do a Receive From Network directly to your mainframe, follow
the instructions in “Tar File SMP/E Receive” on page 3-45 before proceeding. This
section is applicable only if you are not performing an SMP/E Receive From Network directly to your mainframe.
Step 3. Copy SMP/E Installation Dialog File from z/OS UNIX to z/OS
Compuware provides an ISPF SMP/E installation dialog in one of the z/OS UNIX System
Services files created by the Receive From Network batch job. Customize and submit the
JCL below to copy that install file to your z/OS system.
Figure 3-27. Sample JCL to Copy Installation Dialog File
//jobname JOB (account),'programmer-name',NOTIFY=&SYSUID,
// MSGLEVEL=(1,1),MSGCLASS=?,CLASS=?,REGION=0M
//*********************************************************************
//* This job will copy the install file to a dataset that will *
//* be customized to complete the SMP/E install. *
//* *
//* @@@@@> INPUT WITHIN THIS JOB IS CaSe sENsiTivE. <@@@@@@ *
3-32
Enterprise Common Components Installation and Customization Guide
//* *
//* NOTES: *
//* 1 - Update the jobcard as required. (REGION=0M is recommended.) *
//* 2 - The PATH='/temp/nts/#######/SMPRELF' on the SMPDIR DD must *
//* point to the directory that contains the install file. *
//* Change the '/temp/nts' portion to what was used when you *
//* customized the PATH= variable on the SMPNTS DD in the *
//* Receive From Network JCL. Change the ####### to the *
//* id= number located on the PACKAGE statement in the Receive *
//* From Network JCL. *
//* 3 - Change ???????? to the SMP/E dataset prefix you used when *
//* you customized the Receive From Network JCL. This should be *
//* the same as the dataset name prefix used for your SMP/E *
//* Global CSI. *
//* 4 - Examine the name= value. The F0 qualifier references the *
//* English version of the installation dialog. For the Japanese *
//* version of the dialog, change the F0 qualifier to F99. *
//*********************************************************************
//SMPER1 EXEC PGM=GIMUNZIP,REGION=0M
//SMPDIR DD PATHDISP=KEEP,PATH='/temp/nts/#######/SMPRELF'
//SMPOUT DD SYSOUT=*
//SYSPRINT DD SYSOUT=*
//SYSUT3 DD UNIT=SYSALLDA,SPACE=(6160,(0230,0760))
//SYSUT4 DD UNIT=SYSALLDA,SPACE=(6160,(0230,0760))
//SYSIN DD *
<GIMUNZIP>
<ARCHDEF
name="IS.PROD.HC.V030000.CPWR.MLHC300.F0.pax.Z"
replace="YES"
newname="????????.MLHC300.INS">
</ARCHDEF>
</GIMUNZIP>
//
Part 2: Customize Installation JCL with ISPF
The ISPF Installation JCL Customization Facility uses screens to gather your installation information. It then uses that information to build the jobs needed to complete the
SMP/E installation.
Step 1. Make Note of HLQ, Global Zone CSI, and Installation File Name
Note: To prevent possible conflicts, Compuware strongly recommends that all
Compuware products and components distributed via SMP/E share a single
Global zone reserved solely for Compuware products. Target and distribution
zones cannot be shared.
The installation process utilizes System Modification Program Extended (SMP/E). For more information about this type of installation, consult the IBM SMP/E Reference or the
IBM SMP/E User’s Guide.
In using Receive from Network (RFN) to receive and install this product, the following steps should have already been performed:
1. Using JCL provided with the order of this product, you should have allocated and initialized an SMP/E Global Zone Consolidated Software Inventory (CSI) that will be used during this install. Optionally, you may have had an SMP/E Global Zone CSI already prepared for Compuware products.
Make a note of the high-level qualifier (HLQ) you specified when creating the CSI:
__________________________________________________________________________
Make a note of the full Global Zone CSI name:
__________________________________________________________________________
2. Using JCL provided with the order of this product, you should have performed an
SMP/E Receive from Network for the product(s) ordered. The Installation file was
Receive From Network (RFN) Installation
3-33
copied in “Step 3. Copy SMP/E Installation Dialog File from z/OS UNIX to z/OS” on page 3-31.
After running the job, make a note of the installation file name:
__________________________________________________________________________
Step 2. Select Installation Components
The ISPF Installation JCL Customization Facility uses screens to gather your installation information. It then uses that information to build the jobs needed to perform the SMP/E installation.
Notes:
1. The Installation JCL Customization Facility ruses ISPF and REXX to generate customized jobstreams and store them in the Installation PDS.
2. Slight variations in the following procedure may exist depending on the format in which you received the product.
Begin the process of installing products using the ISPF Installation JCL Customization
Facility as follows:
1. Invoke the installation facility for the Enterprise Common Components product by entering the TSO EXECUTE command with the dataset name of the installation library followed by $$ECINST. For example:
TSO EX 'hlq.MLHC300.INS($$ECINST)' where hlq is the high-level qualifier you entered when transferring files to the
mainframe. The exact dataset name can be found in the notes you made in “Step 1.
Make Note of HLQ, Global Zone CSI, and Installation File Name” on page 3-32.
The SMP/E Installation JCL Customization Facility screen (Figure 3-28) is displayed.
Figure 3-28. Selecting Components to Install
Compuware Enterprise Common Components Release 3.2
SMP/E Installation JCL Customization Facility
Command ==>
Place an "S" by one or more of the following components to select that
component for Installation JCL Customization.
To deselect a component, delete the "S"
_ Host Communications Interface 9.0
Press PF1 for help, END to exit.
2. Type an S to the left of each component you want to install.
3. Press Enter. To indicate your choices, the word SELECTED will be displayed in the
Status column next to each component chosen.
4. To modify a selection, add or delete the S to the left of the component.
3-34
Enterprise Common Components Installation and Customization Guide
5. When you are satisfied with your selections, press Enter again to start the JCL
customization process. The screen shown in Figure 3-29 is displayed.
Step 3. Specify Installation Environment Information
Note: Depending on your installation choices, you may not see all of the screens documented herein.
Figure 3-29. Installation Environment Screen
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Host Communications Interface
Please enter the following parameters.
Do you want to enter SMS parameters? NO
DASD Unit: SYSDA
DASD Volser (optional):
SMP/E Work Unit: SYSDA
DASD DSN High Level Qualifier
GLOBAL SMP/E dataset High-level Qualifier: COMPWARE.GLOBAL
This HLQ must match the value in the Receive From Network job.
Press Enter to continue, PF1 for help, or END to return to previous panel.
This screen prompts you to enter information about the installation environment. Notice that the names of the components selected for installation are listed below the
Command prompt. Those names will remain there during the rest of this procedure.
1. Specify installation information as follows:
Do you want to enter SMS parameters?
If you specify YES in the SMS Parameters field, you will be prompted to enter SMS
(Storage Management Subsystem) parameters on the next screen. Depending on your site’s SMS installation options, default SMS parameters may be supplied when datasets are being allocated during execution of the job. If so, or if you do not want to specify SMS parameters, enter NO. Otherwise, enter YES to supply or override the SMS parameters. The default value is NO.
DASD unit
Enter a valid DASD unit name. The value of this field will be used in the UNIT= parameter of the DD statements that allocate non-VSAM libraries and datasets.
The default value is SYSDA.
DASD volser
This field is optional. If a volume is specified, SMP/E will use it as the target for library and dataset allocation.
SMP/E work unit
Enter the name of a DASD unit to use for allocating SMP/E work files. The default value is SYSDA.
DASD DSN High Level Qualifier
Enter the High-level-qualifier of the datasets created by the download procedure.
Receive From Network (RFN) Installation
3-35
Global SMP/E dataset high-level qualifier
The HLQ name can be found in the notes you made in “Step 1. Make Note of
HLQ, Global Zone CSI, and Installation File Name” on page 3-32.
2. Press Enter to continue.
Step 4. Specify SMS Parameters
If, in the previous step, you specified NO in the SMS Parameters field, you can skip this step.
The screen shown in Figure 3-30 was displayed when you pressed Enter in the previous
step.
Figure 3-30. Specifying SMS Parameters
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Host Communications Interface
Enter any or all of the following SMS parameters.
Data Class: dataclas
Storage Class: storclas
Management Class: mgmtclas
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the data class, storage class, and/or management class parameters for the SMS operating environment as follows:
Data Class
Specify the eight-character data class name for SMS.
Storage Class
Specify the eight-character storage class name for SMS.
Management Class
Specify the eight-character management class name for SMS.
Note: Installation defaults are not displayed on this screen. They will be applied during execution of the SMP/E jobstream generated by this procedure. If your site does not supply defaults or you want to override the supplied defaults, enter the desired SMS parameters on this screen.
2. Press Enter to continue.
3-36
Enterprise Common Components Installation and Customization Guide
Step 5. Specify Global CSI Dataset Name
The screen shown in Figure 3-31 was displayed when you pressed Enter in the previous
step.
Figure 3-31. Specifying Global CSI Dataset Name
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Host Communications Interface
The following dataset name will be used for the Global CSI:
COMPWARE.GLOBAL.CSI
If this is not the Global CSI used during the Receive From Network job,
enter the correct Global CSI DSN.
The dataset currently does not exist.
Press Enter to continue, PF1 for help, or END to return to previous panel.
Enter the DSN for the existing global CSI as follows:
1. Verify that the global CSI dataset name is correct. If necessary, change the name to
2. Press Enter.
Step 6. Specify job card Information
The screen shown in Figure 3-32 on page 3-37 was displayed when you pressed Enter in
the previous step. It prompts you for job card information.
Receive From Network (RFN) Installation
3-37
Figure 3-32. Entering Job Card Information
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Host Communications Interface
Enter Job Card Information:
//$$$$$$$$ JOB ('ACCT'),'USER NAME',
// CLASS=?,MSGCLASS=?,NOTIFY=PROGRAMMER
//* OPTIONAL JES PARAMETER CARD COULD GO HERE
//*
//*
NOTE: The class selected MUST allow enough CPU time for long running jobs.
Jobs $xxI2APL and $xxI3ACC can easily exceed 5 CPU minutes each.
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the job card information for the ISPF Installation JCL Customization Facility by updating the supplied model job card to follow your site standards. You may enter up to five lines of job information.
The installation facility will set the $$$$$$$$ value equal to the member name of each job created. You also have the option of specifying the job name using the format xxxxxxx$ or xxxxxxxx, where the x’s are whatever name you choose. If you set it to xxxxxxx$, the installation facility will set the job name for each job to xxxxxxx and append a number to it. A letter will be appended for jobs 10 and above. If you set it to xxxxxxxx, the installation facility will use the specified name for all jobs created.
Note: The job class specified must allow enough CPU time for long-running jobs.
2. Press Enter to continue.
Step 7. Specify SMP/E High-Level Qualifiers
The screen shown in Figure 3-33 on page 3-38 was displayed when you pressed Enter in
the previous step. It prompts you for the SMP/E high-level qualifiers of the components previously selected for installation.
3-38
Enterprise Common Components Installation and Customization Guide
Figure 3-33. Specifying SMP/E High-Level Qualifiers
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Host Communications Interface
Enter the following information:
Host Commmications Interface
SMP/E Dataset High-level Qualifier: COMPWARE.MLHCnnn
Press Enter to continue, PF1 for help, or END to return to previous panel.
Note: If a high-level qualifier is longer than 28 characters, the installation facility is not able to generate a default dataset name for the target and distribution zones. You can either change the high-level qualifier entered, or manually modify the zone dataset names to valid lengths.
1. Specify the high-level qualifiers as applicable for your installation as follows:
Component-Specific SMP/E Dataset High-level Qualifier
Enter a value to be used in generating names of component-specific datasets, including target and distribution zone CSIs, and their respective non-SMP/E target and distribution libraries. The value entered cannot exceed 28 characters.
2. Press Enter.
Step 8. Specify Target and Distribution Zones
The screen shown in Figure 3-34 on page 3-39 is an example of what was displayed when
you pressed Enter in the previous step.
Receive From Network (RFN) Installation
3-39
Figure 3-34. Specifying Target and Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Host Communications Interface
Enter the following information for Host Communications Interface
Distribution Zone Name: LHCnnnD
DZone CSI_Dataset Name: COMPWARE.MLHCnnn.DZONE.CSI
DZone CSI currently does not exist
Target Zone Name: LHCnnnT
TZone CSI Dataset Name: COMPWARE.MLHCnnn.TZONE.CSI
TZone CSI currently does not exist
Japanese Language Support? NO
Modify detail value for Component datasets Yes/No/Reset? N
Default values are being used
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the target and distribution zone information as follows:
Distribution Zone Name
Specifies the name of the SMP/E distribution zone used by the product to be installed. The name you specify must be unique within the global zone. The default is LHCnnnD.
DZone CSI Dataset Name
Specifies the dataset name of the SMP/E distribution zone used by the product to be installed.
DZone CSI currently exists/does not exist
Indicates whether the distribution zone CSI dataset exists.
Target Zone Name
Specifies the name of the SMP/E target zone used by the product to be installed.
The name you specify must be unique within the global zone. The default is
LHCnnnT.
TZone CSI Dataset Name
Specifies the dataset name of the SMP/E target zone used by the product to be installed.
TZone CSI currently exists/does not exist
Indicates whether the target zone CSI dataset exists.
Japanese Language Support
CSS can allocate message and panel libraries to display Japanese language characters rather than English. Specify YES to allocate and install the Japanese language message and panel libraries. Specify NO to bypass allocating these libraries.
Modify detail value for Component datasets Yes/No/Reset? N
Default values are being used.
Note: If either the Target or Distribution CSI's already exist, the following screen will display.
3-40
Enterprise Common Components Installation and Customization Guide
Figure 3-35. Installing into Pre-existing Target/Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility - Tutorial
CAUTION. The CSI(s) for either or both the Target and Distribution Zones
already exist. If you are installing into an existing set of Target and
Distribution Zones, there is a possibility of destroying data in or related
to the existing Zones.
Compuware strongly suggests you install components into new Zones.
If you try to install a component into the same Zones in a pre-existing CSI,
the SMPMCS for ECC is designed to delete previous releases of that component.
To install a new release of a component into a CSI without deleting previous
releases, you must install using a different Zone Name (default).
2. You can modify or enter detail values for Component datasets by specifying Y (yes).
3. To reset any overridden detail values to default, specify R (reset).
4. Press Enter.
Step 9. Verify Installation Information
When you pressed Enter in the previous step, the first of a series of confirmation screens was displayed. On each confirmation screen you have the following choices.
• To accept the information on the screen, press Enter.
• To correct a particular parameter, press END (PF3) to return to the associated entry screen.
After you accept the information on each of the confirmation screens, the installation process will continue.
Step 10. Process the JCL
The screen shown in Figure 3-36 was displayed when you pressed Enter the final time in
the previous step.
Figure 3-36. Confirming JCL Processing
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Processing Verification Screen
Command ==>
Customizing: Host Communications Interface
Press Enter to begin customizing the JCL.
Receive From Network (RFN) Installation
3-41
1. Press Enter to start the processing that builds customized JCL members or press END
(PF3) to cancel the installation.
When you press Enter, the progress of the JCL customization process is displayed in a scrollable area on the screen. You can scroll up or down to view the list of jobs and the members generated.
2. After the installation JCL has been created, press END (PF3). A screen is displayed
informing you that a parameter report has been generated (Figure 3-37). This report
details the JCL created and lists the parameters and execution information used during installation.
Figure 3-37. Report Member Detailing JCL Processing
Enterprise Common Components
SMP/E Installation JCL Customization Facility
The following PDS member contains a report of all parameters used during
customization and a log of all JCL members created:
hlq.MLHCnnn.INS($$xxRPT)
Press Enter to browse the report, END to exit.
3. If you want to browse the report at this time, press Enter. You can also examine the report later by accessing the installation library report member shown on this screen.
4. Press END (PF3). The screen first displayed in Figure 3-28 on page 3-33 will be
redisplayed, showing a status of COMPLETE for each component (Figure 3-38).
Figure 3-38. Displaying Completion Status
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Place an "S" by one or more of the following components to select that
component for Installation JCL Customization.
To deselect a component, delete the "S"
_ Host Communications Interface 03.00.00 COMPLETE
Press PF1 for help, END to exit.
5. Press END (PF3). The screen shown in Figure 3-39 on page 3-42 will be displayed
instructing you to refer to the product installation guides to complete the installation process.
3-42
Enterprise Common Components Installation and Customization Guide
Figure 3-39. Final JCL Customization panel
Command ==>
Place an "S" by one or more of the following components to select that
component for Installation JCL Customization.
To deselect a component, delete the "S"
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Enterprise Common Components
SMP/E Installation JCL Customization Facility return to the ECC Installation and Customization Guide.
Press END to exit.
Note: To complete the installation of the selected component(s),
S Compware Common Components 09.00.00 COMPLETE
6. The processing of the ISPF Installation JCL Customization Facility is now finished.
Press END (PF3) to exit.
Note: Compuware recommends you maintain availability to your customized install library. Otherwise, it may be necessary to unload and recustomize the install library from product or maintenance media to perform future maintenance.
Part 3: Install Host Communications Interface with
SMP/E
There are six sample jobs for using SMP/E to install Host Communications Interface. Use
the dataset name found in the notes you made in “Step 1. Make Note of HLQ, Global
Zone CSI, and Installation File Name” on page 3-32.
Installation JCL members are described in the following table.
Table 3-3. Installation JCL Members
Member Function
$HCI0GBA
Unnecessary for a Receive From Network-initiated Install.
$HCI1PRA
$HCI1PRB
Performs the allocation of the zones and related SMP/E datasets.
Initializes the CSIs with the required entries.
$HCI2RCV
$HCI3APL
$HCI4ACC
Unnecessary for a Receive From Network-initiated Install.
Applies the base code and maintenance.
Accepts the base code.
Note: Except where otherwise noted, the return code from all jobs should be zero.
Step 1. Allocate Libraries and SMP/E Datasets
This step allocates target and distribution zone CSIs as well as product-specific SMP/E datasets. These datasets include the product-specific load libraries.
The installation facility has created a job called $HCI1PRA that allocates the required libraries and datasets.
Receive From Network (RFN) Installation
3-43
Note: The space allocations used are based on 3390 DASD. If you use 3380 DASD, you may decide to change the BLKSIZE for the load library to 6356 for a better blocking factor.
1. Review the job $HCI1PRA for any necessary changes.
2. Submit the job to start the allocation process.
Step 2. Initialize the Target and Distribution Zone CSIs
This step initializes the Host Communications Interface target and distribution zone
CSIs. The installation facility has created a job called $HCI1PRB that performs the initialization.
1. Review the job $HCI1PRB for any necessary changes.
Note: Before you submit this job, make sure the job submitted in the previous step has completed.
2. Submit the job to start the initialization process. This job uses REP statements rather than ADD statements to simplify rerunning the job. It is normal to receive a return code of 4 with the following messages:
GIM56501W The aaaaaa subentry was added rather than replaced
because it did not exist.
GIM27701W aaaaaaaa ENTRY bbbbbbbbbbbbbbbbb does not exist. the replace
operation has been changed to an add.
Otherwise, the return code should be 0.
Step 3. Review HOLDDATA
At times, installing base code and maintenance requires additional actions that must be performed after a PTF(s) is applied. In these cases, the PTF is identified as an exception with:
++HOLD and the HOLDDATA contains information on the additional actions you must perform to completely implement the change. The HOLDDATA can be found in the SMPRPT output from the RFN job.If the SMPRPT is not available, you can execute a batch SMPE job against the Global Zone with the following commands to display the HOLDDATA:
SET BOUNDARY(GLOBAL)
LIST HOLDDATA FORFMID(MLHCnnn)
CAUTION:
It is very important that you perform any HOLDDATA action. Failure to do so can cause unpredictable results, including incorrect data and abends. It is possible that the installation does not have any hold actions.
Step 4. Apply the Base Code and Cumulative Maintenance to the Target
Libraries
This step applies the Host Communications Interface base code and cumulative maintenance to the target zone. The installation facility has created a job called
$HCI3APL that performs the apply process.
3-44
Enterprise Common Components Installation and Customization Guide
CAUTION:
Be sure to run $HCI3APL in a job class suitable for long-running batch jobs.
Note: The default control statements apply the base FMID and all cumulative maintenance. However, you may want to run an APPLY CHECK before applying the software.
1. Review the job $HCI3APL for any necessary changes.
2. Submit the job to start the apply process.
When the base code is applied, it is normal to receive a return code of 4 with messages similar to the following:
GIM43401W MODULE ADSIM100 IN SYSMOD MLXTnnn
was not installed in any target zone.
GIM43401W MODULE ADSIM101 IN SYSMOD MLXTnnn
was not installed in any target zone.
GIM43401W MODULE ADSIM102 IN SYSMOD MLXTnnn
was not installed in any target zone.
Note: An APPLY may end with a non-zero return code, even though the APPLY CHECK ended with RC=0. This is because the APPLY may invoke external utilities, such as IEBCOPY or the linkage editor, while the APPLY CHECK only checks the SMP/E environment. A return code of 4 is expected from the linkage editor with messages similar to the following:
IEW2454W 9203 SYMBOL module-name UNRESOLVED.
NO AUTOCALL (NCAL) SPECIFIED.
Step 5. Accept the Base Code to the Distribution Libraries
This step accepts the Host Communications Interface base code to the distribution libraries.
The installation facility has created a job called $HCI4ACC that accepts the base code into the distribution libraries.
CAUTION:
Be sure to run $HCI4ACC in a job class suitable for long-running batch jobs.
Note: The default control statements accept the base FMID. However, you may want to run an ACCEPT CHECK before accepting the software.
1. Review the job $HCI4ACC for any necessary changes.
2. Submit the job to start the accept process.
Note: An ACCEPT may end with a non-zero return code, even though the ACCEPT
CHECK ended with RC=0. This is because the ACCEPT may invoke external utilities, such as IEBCOPY or the linkage editor, while the ACCEPT CHECK only checks the SMP/E environment.
Part 4: Configure Host Communications Interface
After the The Host Communications Interface (HCI) installation has been completed, refer to the appropriate Compuware product manual for specific customization/configuration instructions.
Receive From Network (RFN) Installation
3-45
Tar File SMP/E Receive
This section contains instructions only for those sites unable to do a Receive From
Network directly to the mainframe.
Step 1. Download the Tar File
The product order e-mail contains a link to a .tar file. Click the link and save the file to your default download directory.
Step 2. Create USS Directory and File Structure
Certain directories, sub-directories, and files must exist before transferring the installation package to the Unix System Services (USS) workspace. To create them,
customize and run the sample JCL shown in Figure 3-40.
Figure 3-40. Sample JCL to Create USS Directory and File Structure
//jobname JOB (account),'programmer-name',NOTIFY=&SYSUID,
// MSGLEVEL=(1,1),MSGCLASS=?,CLASS=?,REGION=0M
//*********************************************************************
//* This job will create the directories / files necessary for
//* housing the RFN tarball on your USS workspace.
//*
//* CAUTION: This is not a complete job. Before using this JCL,
//* you will have to make modifications.
//*
//* @@@@@> INPUT WITHIN THIS JOB IS CaSe sENsiTivE. <@@@@@@
//*
//* Notes:
//* 1 - Update jobcard as required. REGION=0M is important!
//* 2 - If necessary, change the dataset name on the SYSEXEC DD
//* card to match the name of your BPX REXX library.
//* 3 - Change all ???????? to the desired USS work directory.
//* (Be careful with the placement of the '/' character(s).)
//* 4 - Change nnnnnnn to the high level portion of the name of the
//* .tar file that was downloaded earlier.
//*
//* EXAMPLES:
//* If your USS work directory is sub directory 'work' under
//* your 'userid' directory, then:
//* C '????????' '/userid/work'
//* If the downloaded tarball file is 0000005.tar, then:
//* C 'nnnnnnn' '0000005'
//*********************************************************************
//STEP1 EXEC PGM=IKJEFT01,DYNAMNBR=50
//SYSEXEC DD DISP=SHR,DSN=SYS1.SBPXEXEC
//SYSTSPRT DD SYSOUT=*
//SYSPRINT DD SYSOUT=*,TERM=TS
//SYSOUT DD SYSOUT=*,TERM=TS
//SYSTSIN DD *
oshell cd ????????
oshell rm -r rfn
oshell mkdir rfn
oshell cd ????????/rfn
oshell mkdir -p rfn/nnnnnnn
oshell mkdir -p rfn/nts
oshell mkdir -p rfn/tarball
//
3-46
Enterprise Common Components Installation and Customization Guide
Step 3. Copy the Tar File to USS Tarball Directory
Use an FTP client such as WS_FTP or FileZilla to copy the downloaded .tar file to your mainframe USS tarball sub-directory created by the JCL in Step 2 above. The example in
Figure 3-41 shows FileZilla, a free FTP client, being used to drag-and-drop the .tar file into
the tarball folder.
Figure 3-41. Copying Tar File to Tarball Folder
Step 4. Extract Tar File Contents
Before completing the Receive From Network process, the contents of the .tar file must be extracted into the directory and file structure created in Step 2 above. To extract the
contents of the .tar file, customize and run the sample JCL shown in Figure 3-42 on page
Receive From Network (RFN) Installation
3-47
Figure 3-42. Sample JCL to Extract Contents of Tar File
//jobname JOB (account),'programmer-name',NOTIFY=&SYSUID,
// MSGLEVEL=(1,1),MSGCLASS=?,CLASS=?,REGION=0M
//*********************************************************************
//* This job will extract a tarball file, creating the required
//* directory / file structure for the Receive from Network job.
//*
//* CAUTION: This is not a complete job. Before using this JCL,
//* you will have to make modifications.
//*
//* @@@@@> INPUT WITHIN THIS JOB IS CaSe sENsiTivE. <@@@@@@
//*
//* Notes:
//* 1 - Update jobcard as required. REGION=0M is important!
//* 2 - If necessary, change the dataset name on the SYSEXEC DD
//* card to match the name of your BPX REXX library.
//* 3 - Change all ???????? to the desired USS work directory.
//* (Be careful with the placement of the '/' character(s).)
//* 4 - Change nnnnnnn to the high level portion of the name of the
//* .tar file that was downloaded earlier.
//*
//* EXAMPLES:
//* If your USS work directory is sub directory 'work' under
//* your 'userid' directory, then:
//* C '????????' '/userid/work'
//* If the downloaded tarball file is 0000005.tar, then:
//* C 'nnnnnnn' '0000005'
//*********************************************************************
//*
//*--------------------------------------------------------------------
//* CREATE COMMAND FILE
//*--------------------------------------------------------------------
//BUILD1 EXEC PGM=IKJEFT01
//SYSEXEC DD DISP=SHR,DSN=SYS1.SBPXEXEC
//SYSTSPRT DD SYSOUT=*
//SYSPRINT DD SYSOUT=*,TERM=TS
//SYSOUT DD SYSOUT=*,TERM=TS
//SYSTSIN DD *
oshell cat > ????????/rfn/commands.sh
//*--------------------------------------------------------------------
//* POPULATE COMMAND FILE
//*--------------------------------------------------------------------
//BUILD2 EXEC PGM=IKJEFT01
//SYSTSPRT DD SYSOUT=*
//SYSPRINT DD SYSOUT=*,TERM=TS
//SYSOUT DD SYSOUT=*,TERM=TS
//OUT DD PATH='????????/rfn/commands.sh'
//IN DD *
cd ????????/rfn/nnnnnnn
pax -rvf ????????/rfn/tarball/nnnnnnn.tar
//SYSTSIN DD *
OCOPY INDD(IN) OUTDD(OUT) TEXT PATHOPTS(USE)
//*--------------------------------------------------------------------
//* Extract TAR file (execute shell)
//*--------------------------------------------------------------------
//EXTRACT EXEC PGM=BPXBATCH
//STDIN DD PATH='????????/rfn/commands.sh'
//STDOUT DD SYSOUT=*
//STDERR DD SYSOUT=*
//
Step 5. Perform SMP/E Receive
The Receive From Network package is now staged in the USS workspace. Use the sample
JCL provided in the file named smpe_receive.txt to facilitate an SMP/E Receive. Follow
3-48
Enterprise Common Components Installation and Customization Guide
the instructions in the comments of the sample JCL to customize the batch job, with the following additions:
• The host= variable should point to your site, with the appropriate settings for user= and pw=.
• The file= variable should point to ????????/rfn/nnnnnnn/GIMPAF.XML where
???????? is the USS work directory used when running the job to extract the tar file and nnnnnnn is your 7-digit order number.
Submit the customized JCL to perform the RECEIVE. When the job has completed, return to one of the following:
• For Compuware Shared Services: “Step 3. Copy SMP/E Installation Dialog from z/OS
4-1
Chapter 4.
Applying Maintenance
This chapter describes the procedures for applying ECC maintenance given the various methods available for performing maintenance updates. The method which gets used is determined in large part by the process you chose for performing the ECC SMP/E
Installation. Although there are several paths you could have taken to perform the SMP/E installation, ultimately they arrive at only two options
• SMP/E Customization and JCL generation using the Media Browser
• SMP/E Customization and JCL generation using the ISPF Dialogs.
When files are uploaded to the mainframe by the Media Browser and then unloaded, the following files are relevant to the maintenance process:
hlq.CPWR.CYnnnnnn.ABS
— Maintenance Abstracts
hlq.CPWR.CYnnnnnn.HLD
— HOLDDATA
hlq.CPWR.CYnnnnnn.INS
— Installation PDS (ISPF Dialog path)
hlq.CPWR.CYnnnnnn.MNT
— Maintenance file (PTFs)
Note: If you have executed the $$ECCUST ISPF Dialog (see Appendix C, “JCL
CAUTION:
Products using address spaces or server regions where CSS and/or HCI libraries are allocated must be shut down while maintenance is being applied to their CSS libraries and restarted after the maintenance process is complete. This applies especially to Abend-AID for CICS, Compuware Workbench/MMC, and Xpediter/CICS users.
SMP/E Customization & JCL generation using Media
Browser (Option 1)
For option 1 (Media Browser), JCL was generated and stored in dataset
hlq.prodid.SMPE.JCL
The
hlq.prodid.SMPE.JCL file contains the following members related to processing the maintenance files.
$10MNTJB — This jobstream is the JCL that is submitted when Upload SMP/E JCL to
the Mainframe and Submit is clicked in the Media Browser. It is a concatenation of members $14MRECV and $15MAPLY (minus extra jobcards) into a single member.
$14MRECV — This jobstream Receives the maintenance file(s) for installed components. Update JCL statements SMPPTFIN and SMPHOLD to point to the files uploaded from CD/CD-image or Frontline.
$15MAPLY — This jobstream will Apply the maintenance PTFs to the SMP/E files
$16MACPT — This jobstream will Accept the maintenance PTFs to the SMP/E files
4-2
Enterprise Common Components Installation and Customization Guide
Note: These jobstreams contain control statements to process ALL the products selected during the Media Browser Upload function. If you wish to process products
individually, you can execute the $$ECCUST ISPF Dialog (see Appendix C, “JCL
Once you have uploaded the maintenance files to the mainframe (regardless of the method used to obtain them), they are RECEIVED using job $14MRECV and APPLYed using job $15MAPLY. You may need to update job $14MRECV to point to the uploaded files.
During a normal maintenance cycle, we recommend you perform the following steps
Note: Review section “General Maintenance Notes” on page 4-3 before proceeding.
1. Accept previous maintenance (job $16MACPT).
2. RECEIVE new maintenance files (job $14MRECV). Review the HOLDDATA for any special processing needs.
3. Apply the new maintenance to your test system (job $15MAPLY).
4. Validate the new maintenance functions properly on your system.*
5. Migrate new maintenance into your production environment.*
*Your site processes will determine how you perform steps 4 and 5.
SMP/E Customization & JCL generation using ISPF
Dialogs (Option 2)
JCL for applying maintenance to ECC products is generated by the $$ECCUST ISPF
Dialog. See Appendix C, “JCL Customization” if you have not executed the ISPF Dialog
yet. The following jobs will be customized:
• $CSM1RCV (CSS), $LMM1RCV (LMS), and $HCM1RCV (HCI) perform an SMP/E receive of the maintenance file. Modify SMPPTFIN and SMPHOLD DD statements as necessary.
• $CSM2APL (CSS), $LMM2APL (LMS), or $HCM1APL (HCI) performs an SMP/E apply to target libraries.
• $CSM3ACC (CSS), $LMM3ACC (LMS), or $HCM3ACC (HCI) performs an SMP/E accept to the respective distribution libraries.
The following steps are recommended for the maintenance cycle
Note: Review section “General Maintenance Notes” on page 4-3 before proceeding.
1. Accept any PTFs from a previous maintenance run that have not been accepted yet.
2. Receive the new maintenance PTFs. Review the HOLDDATA for any special processing needs.
3. Apply the new maintenance PTFs.
4. Test the new PTFs for any problems that may arise due to site dependencies.
5. Move them into production and accept the new PTFs. You could wait until the next maintenance run before accepting PTFs if desired.
Applying Maintenance
4-3
General Maintenance Notes
• The SMP/E Installation process only performs an ACCEPT on the Base Code. The maintenance applied during the original installation process is not ACCEPTed until the appropriate maintenance ACCEPT job is run.
• You should review the maintenance abstracts file before applying new maintenance.
The following members in the abstract file contain information on the PTFs supplied for the corresponding products:
$LCXABS
— Compuware Shared Services
$LHCABS
— Host Communications Interface
$LMSABS
— License Management System
• The maintenance RECEIVE job may get RC=4. If the job completes with RC=4, review the job output for the following message
“GIM24801W NO SYSMODS SATISFIED THE OPERANDS SPECIFIED ON THE RECEIVE
COMMAND”
If this message appears, no preventive service is applicable for the specified FMIDs.
• Reviewing HOLDDATA
At times, installing maintenance requires additional actions that must be performed after PTFs are applied. In these cases, the PTF is identified as an exception with
++HOLD and the HOLDDATA contains information on any additional actions you must perform to completely implement the change. It is very important that you perform any HOLDDATA action. Failure to do so can cause unpredictable results, including incorrect data and abends.
It is possible that the maintenance file does not have any hold actions. In this case, the HOLDDATA dataset will be empty.
The following parameter must be added to the APPLY and ACCEPT commands to bypass any HOLDDATA
BYPASS(HOLDUSER(ACTION)
)
• Do NOT perform an ACCEPT on any USERMODs!
4-4
Enterprise Common Components Installation and Customization Guide
5-1
Chapter 5.
CSS Customization
5
Chap 5
The procedures in this chapter are used to customize Compuware Shared Services (CSS) and the Compuware Viewing Facility (Compuware/VF). If you are installing Abend-AID
11.02.00 or higher or Abend-AID for CICS, you must install HCI prior to customizing
CSS. For information about configuring the HCI server, refer to the Abend-AID
User/Reference Guide or the Abend-AID for CICS Installation and Customization Guide.
As shown in Table 5-1, some of the steps in this chapter are required, while others are
optional.
Table 5-1.
CSS Procedure Requirements
Step Number
“Step 1. Implement the Security Exit Program (Optional)”
“Step 2. Install Customized Translation Tables (Optional)”
“Step 3. Make New CSS Load Modules Accessible to Compuware Products
“Step 4. Create the Compile Information Table (Required)”
“Step 5. Activate Compuware ISPF Dialogs (Required)”
“Step 6. Link Compuware/VF and CSS Utilities Tutorials to Your Main
“Step 7. Associate Contact Information File with Compuware/VF
“Step 8. Establish Access to File-AID (Optional)”
“Step 9. Prepare the DDIO Files”
“Step 10. Implement the Language Processor JCL (Required)”
Required
x x x x x
Optional
x x x x x
5-2
Enterprise Common Components Installation and Customization Guide
Step 1. Implement the Security Exit Program (Optional)
The Security Exit program is an optional user-coded module for establishing security at each site. If you want to ensure full security access to file resources, refer to the “CSS
Security Exit” chapter in the Compuware Shared Services User/Reference Guide for detailed information on using the program. A sample Security Exit program is located in
SLCXCNTL sample library member CWASSECU.
If the Security Exit program is present, it is called for each member selected. The Security
Exit program determines if the user command is permitted, and passes the appropriate return code. If the command is unacceptable for one of the selected members, it will not be executed at all.
Because CSS is used by more than one Compuware product, the Security Exit program is executed for each Compuware product that uses CSS. If you are using multiple
Compuware products, you must update your Security Exit program to accommodate those products.
Notes:
1. The sample Security Exit program is for illustration purposes only and does not provide any useful functions. You must update it to serve the needs of your site.
2. This Security Exit program is invoked in the MVS environment and does not provide for CICS services.
3. If CICS Abend-AID/FX or Abend-AID for CICS is installed at your site, or if you are installing Abend-AID for CICS, the Security Exit program must be reentrant.
To Implement the Security Exit Program:
Use the following procedure to implement the CWASSECU Security Exit program:
1. Create the Security Exit program. Use the sample Security Exit program as the basis for your exit.
You must use the program name CWASSECU because other programs reference it and search specifically for this program name.
2. Assemble and linkedit the Security Exit program as a separate load module named
CWASSECU. Linkedit CWASSECU into the same load library as CSS. The SLCXCNTL library member CXJCLSEC contains sample JCL that can be used to assemble and linkedit CWASSECU to the CSS load library.
3. If CICS Abend-AID/FX or Abend-AID for CICS is installed at your site, the Security
Exit program must be reentrant.
CSS Customization
5-3
Step 2. Install Customized Translation Tables (Optional)
Note: If you omit this step, the default translation tables will be used.
You must perform this step if you are using Japanese language support with Abend-AID.
You may optionally perform this step if you have Abend-AID with the following product facilities:
• Abend-AID
– Basic Support
– with Compuware/VF
– with Compuware/VF and Compuware language processor
When necessary, Abend-AID products dump storage in both hexadecimal and character representation. These storage areas will appear in one of two formats:
• Horizontal dump
• Vertical dump
The character representation for either format is controlled by a default translation table.
The default character set is mixed-case English. You can override either, or both, of these default translation tables with customized translation tables. Different customized translation tables can be specified for either dump format. These customized tables may also allow display of certain otherwise non-displayable fields.
If you install vertical and/or horizontal customized translation tables, CWCMTRVT must be used as the load module name for the vertical translation table, and CWCMTRHT must be used as the load module name for the horizontal translation table. A different internal name can be defined to identify a table. The internal table name must be eight characters long. The table length, excluding the table name, must be 256 bytes.
Therefore, the total table length is 264 bytes. If an error is made installing a customized translation table, the Compuware default table is used.
The following SLCXCNTL sample library members contain sample translation tables:
CWCMTRVT
CWCMTRHT
CWCMTRVE
CWCMTRHE
CWCMTRVU
CWCMTRHU
Vertical translation table for uppercase English.
Horizontal translation table for uppercase English.
Vertical translation table for mixed-case English. This is the default vertical translation table that will be used if you choose not to install a customized vertical translation table.
Horizontal translation table for mixed-case English. This is the default horizontal translation table that will be used if you choose not to install a customized horizontal translation table.
Vertical translation table for mixed-case English with the Euro
Character X‘9F’ included.
Horizontal translation table for mixed-case English with the Euro character X’9F’ included.
CSS SLCXCNTL sample library member CXJCLTRT contains the sample JCL to assemble and link-edit customized translation tables.
5-4
Enterprise Common Components Installation and Customization Guide
Step 3. Make New CSS Load Modules Accessible to
Compuware Products (Required)
You must perform this step.
Ensure that the new CSS load modules can be accessed by Compuware products by using one or more of the following methods. Regardless of the method chosen, the CSS load library (SLCXLOAD or a copy of it) should be concatenated in front of any Compuware product library(ies). The method you choose will depend on the Compuware products you have at your site.
• Compuware recommends that you place the CSS load library in the link list. This will provide access to the CSS load modules for TSO users and batch jobs that need CSS
(for example, language processors, CSS utilities, and/or Abend-AID). This also minimizes any JCL changes that might be needed for a CSS upgrade. (A refresh of the
link list is required to activate this change.) Refer to “APF Authorization” on page
2-15 for additional information and cautions about APF authorizations.
• If you have a supported release of Xpediter/CICS installed at your site, you are required to include the CSS load library with the Xpediter/CICS library in the CICS startup JCL or RDO definitions for each CICS region.
• You may also place the CSS load library in the STEPLIB or ISPLLIB for individual TSO logon PROCs, and in the STEPLIB or JOBLIB for batch jobs. These library specifications will override the CSS load library specified in the link list. This is useful for testing a new version of CSS prior to placing it into the link list for production use.
Notes:
1. If you have previously installed CSS and referenced the load library in batch jobs, compile PROCs, CLISTs, or logon PROCs, CSS will be loaded from the STEPLIB,
ISPLLIB, or JOBLIB where it is specified rather than from the link list. Compuware recommends that you review these locations and remove or modify the CSS load library DDs as appropriate. If you have any Compuware product that uses CSS from a
STEPLIB, ISPLLIB, or JOBLIB concatenation, you should include the CSS load library in front of the Compuware product in that library concatenation.
Beginning with CSS 6.0, you have the ability to dynamically allocate the CSS load library as part of the ISPLLIB concatenation. Please refer to Option 1 listed in the next step for more information.
2. For Abend-AID for CICS, specify the CSS, and HCI load library names in the server
JCL. Refer to the Abend-AID for CICS Installation and Customization Guide for more information.
3. If you use the Abend-AID Distributed Viewing Support feature, you must make the
HCI (SLHCLOAD) load library available to the Compuware Viewing Facility either in your TSO logon PROC or CLIST, or dynamically when you start the Viewing Facility.
See “Option 1 — Dynamically Allocate Libraries when Compuware/VF or CSS
Utilities is Executed” on page 5-15 for more information.
4. If you plan to use the Compuware Viewing Facility to view an Abend-AID report, you should use a CSS release that is the same as or more current than the CSS release that was used to write the report or source listing. Using an older CSS release at view-time may cause unpredictable results. In addition, the current Abend-AID load and customization libraries must be available in the link list, through your TSO logon
PROC or CLIST, or dynamically allocated when you invoke the Viewing Facility. This will prevent text merge and CWROUTE errors during view-time.
CSS Customization
5-5
Step 4. Create the Compile Information Table
(Required)
You should perform this step if you plan to use the Compuware Viewing Facility, CSS
Utilities or the Eclipse Compile Facility within Host Explorer (see Compuware Workbench
Installation Guide).
The purpose of this step is to create the compile information table, which is stored in
SLCXTABL. This table contains information about your compilers, compiler libraries,
DB2 pre-compile libraries, CICS translator libraries and some miscellaneous items. A series of ISPF dialog panels will take you through the table creation process. When you have finished creating the table, you will have to make it available to the Compuware
Viewing Facility and/or CSS Utilities. See “Step 5. Activate Compuware ISPF Dialogs
For the Eclipse Compile Facility, the compile information table is accessed to populate the Preprocessor Compile Libraries dialog when the Import button is selected (see Host
Explorer product Help).
Create the Compile Information Table:
1. You must edit the CXUECIN2 member of the SLCXCNTL sample library. To avoid having your modifications overlaid by future maintenance, you may want to copy the member to a non-SMP/E controlled library that is in your SYSPROC concatenation. Follow the instructions that are in the member. You will need the name of your CSS panel library, SLCXPENU, and your CSS REXX EXEC/CLIST library,
SLCXEXEC.
2. If you placed the member, CXUECIN2, in a library that is in your SYSPROC concatenation, then you may invoke the REXX EXEC as follows: TSO %CXUECIN2.
Otherwise, you may invoke it as follows: TSO EXEC
'your.dataset.library(CXUECIN2)'.
The first panel displayed is the "Install Menu". See Figure 5-1below.
Figure 5-1. Compile Information Table - Install Menu
Compuware CSS Utilities --------- Install Menu --------------------------------
COMMAND ===>
Enter the name of the library, which is used to store the compile information
that you supply from the options below. If the library does not exist, it
will be allocated.
===>
If you have already supplied the compile information in a prior installation
and you want to copy that information to a new library, then enter the
'old' library name below. Use the 'C' option to copy from the library named
below to the library named above.
===>
Enter an option on the command line.
1.) Select compilers
2.) Enter compiler libraries
3.) Enter DB2 IDs and precompile libraries (optional)
4.) Enter CICS IDs and translator libraries (optional)
5.) Enter miscellaneous information
A.) Process options 1 through 5
C.) Copy a prior installation's information to a new library
Press ENTER to process or enter END command to terminate
The first field is the name of the Compile Information table. All of the information entered will be saved in this table. If the file does not exist, then it will be allocated for you.
5-6
Enterprise Common Components Installation and Customization Guide
The second field is used during the COPY command. See “C. Copy a Prior
Installation's Information to a New Library” on page 5-12.
Options:
1. Select Compilers
This option displays the available compilers that the Compile Facility supports. Place a Y next to each compiler that your site uses and you want your programmers to be able to use with the Compile Facility. You must enter this option first and select at
least one compiler. See Figure 5-2 on page 5-6 and Figure 5-3 on page 5-6 below.
Figure 5-2. Compile Information Table - Select Compilers (1 of 2)
Compuware CSS Utilities ------- Select Compilers ------------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: +
COBOL:
OS/VS COBOL ===> N (Y/N)
VS COBOL II ===> N (Y/N)
COBOL/370 ===> N (Y/N)
COBOL/MVS ===> N (Y/N)
COBOL/390 ===> N (Y/N)
ENTERPRISE/COBOL ===> N (Y/N)
COBOL5 ===> N (Y/N)
CA OPTIMIZER ===> N (Y/N)
5.1 DDNames ===> N (Y/N)
Assembler:
Assembler H ===> N (Y/N)
High Level Assembler ===> N (Y/N)
PL/I:
PL/I ===> N (Y/N)
PLI/370 ===> N (Y/N)
Press ENTER to process or enter END command to terminate
Figure 5-3. Compile Information Table - Select Compilers (2 of 2)
Compuware CSS Utilities ------- Select Compilers ------------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: -
CA OPTIMIZER ===> N (Y/N)
5.1 DDNames ===> N (Y/N)
Assembler:
Assembler H ===> N (Y/N)
High Level Assembler ===> N (Y/N)
PL/I:
PL/I ===> N (Y/N)
PLI/370 ===> N (Y/N)
VA/PLI ===> N (Y/N)
ENTERPRISE/PLI ===> N (Y/N)
C Language:
C/MVS ===> N (Y/N)
C/390 ===> N (Y/N)
C/ZOS ===> N (Y/N)
Press ENTER to process or enter END command to terminate
Note: On the Compile Information Table screen shown in the Figure 5-2 on page 5-6,
enter YES in the 5.1 DDNames field if you are using CA OPTIMIZER and the release 5.1 DDNames SYSUT7, SYSUT8, and CAISTATS are to be allocated.
CSS Customization
5-7
2. Enter Compiler Libraries
This option allows you to supply the library names for the compiler you selected in
Option 1. See Figure 5-4 on page 5-7 through Figure 5-7 on page 5-8. The compilers
that you selected will have their corresponding arrow indicators highlighted and the field names will be modifiable.
Figure 5-4. Compile Information Table - Enter Compiler Libraries (1 of 4)
Compuware CSS Utilities ------ Compiler Libraries -----------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: +
COBOL Libraries:
OS/VS COBOL ===>
Linkedit SYSLIB ===>
VS COBOL II ===>
Linkedit SYSLIB ===>
COBOL/370 ===>
Linkedit SYSLIB ===>
COBOL/MVS ===>
Linkedit SYSLIB ===>
COBOL/390 ===>
Linkedit SYSLIB ===>
ENTERPRISE/COBOL ===>
Linkedit SYSLIB ===>
Press ENTER to process or enter END command to terminate
Figure 5-5. Compile Information Table - Enter Compiler Libraries (2 of 4)
Compuware CSS Utilities ------ Compiler Libraries -----------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: - +
Linkedit SYSLIB ===>
CA OPTIMIZER ===>
Linkedit SYSLIB ===>
ASSEMBLER Libraries:
Assembler H ===>
High Level Assembler ===>
PL/I Libraries:
PL/I ===>
Linkedit SYSLIB ===>
===>
PLI/370 ===>
===>
Linkedit SYSLIB ===>
Press ENTER to process or enter END command to terminate
5-8
Enterprise Common Components Installation and Customization Guide
Figure 5-6. Compile Information Table - Enter Compiler Libraries (3 of 4)
Compuware CSS Utilities ------ Compiler Libraries -----------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: - +
Linkedit SYSLIB ===>
VA/PLI ===>
Run-time LIBRARY ===>
Linkedit SYSLIB ===>
ENTERPRISE/PLI ===>
Run-time LIBRARY ===>
Linkedit SYSLIB ===>
C Language Libraries:
C/MVS ===>
LE LIBs ===>
Compiler SYSMSGS ===>
Linkedit SYSLIB ===>
C/390 ===>
LE LIBs ===>
Press ENTER to process or enter END command to terminate
Figure 5-7. Compile Information Table - Enter Compiler Libraries (4 of 4)
Compuware CSS Utilities ------ Compiler Libraries -----------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: -
Linkedit SYSLIB ===>
C Language Libraries:
C/MVS ===>
LE LIBs ===>
Compiler SYSMSGS ===>
Linkedit SYSLIB ===>
C/390 ===>
LE LIBs ===>
Compiler SYSMSGS ===>
Linkedit SYSLIB ===>
C/ZOS ===>
LE LIBs ===>
Compiler SYSMSGS ===>
Linkedit SYSLIB ===>
Press ENTER to process or enter END command to terminate
Libraries entered on these screens depend on the compile processors used at your site. The following types of libraries can be entered on this screen:
– Compiler libraries
– SYSLIB libraries
– Compiler dependent libraries
Compiler libraries describe the datasets that contain the compile processor load modules. These libraries are required only if the processor libraries are not already included in the concatenation lists for LPA or LINKLIST. When these libraries are supplied they will appear in the STEPLIB DD of the compile JCL.
The SYSLIB libraries describe the datasets to be used for the primary resolution of external references by the linkage editor or binder. For example, the L/E library,
SCEELKED. When these libraries are supplied, they will appear in the SYSLIB DD of the linkedit step.
CSS Customization
5-9
Compiler dependent libraries are for those compilers that have additional library requirements. For example, the C language SYSMSGS library or the L/E library,
SCEERUN.
3. Enter DB2 IDs and Precompile Libraries (Optional)
If your site has DB2, this option will allow you to define DB2 identifiers and associate
the identifiers with DB2 libraries. See Figure 5-8 and Figure 5-9 below. When an
identifier is selected, the associated datasets will appear in the STEPLIB DD of the precompile step and in the SYSLIB DD of the linkedit step. The DB2 IDs will appear
on the Compile Menu. See Figure 5-13 on page 5-13.
Figure 5-8. Compile Information Table - Enter DB2 IDs and Precompile Libraries (1 of 2)
Compuware CSS Utilities --- DB2 Precompile Libraries --------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: +
These libraries are used in the DB2 precompile step. The ID is displayed
on the 'Compile Menu'. When the programmer selects one of the IDs from
the 'Compile Menu', the ID is matched to the corresponding library name(s)
that are listed here. You may have up to two libraries with the same ID
name. The 'Compile Menu' can display up to 8 unique IDs.
ID DB2 Precompile Libraries
(1) ===> ===>
(2) ===> ===>
(3) ===> ===>
(4) ===> ===>
(5) ===> ===>
(6) ===> ===>
(7) ===> ===>
(8) ===> ===>
(9) ===> ===>
(10) ===> ===>
(11) ===> ===>
Press ENTER to process or enter END command to terminate
Figure 5-9. Compile Information Table - Enter DB2 IDs and Precompile Libraries (2 of 2)
Compuware CSS Utilities --- DB2 Precompile Libraries --------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: -
ID DB2 Precompile Libraries
(1) ===> ===>
(2) ===> ===>
(3) ===> ===>
(4) ===> ===>
(5) ===> ===>
(6) ===> ===>
(7) ===> ===>
(8) ===> ===>
(9) ===> ===>
(10) ===> ===>
(11) ===> ===>
(12) ===> ===>
(13) ===> ===>
(14) ===> ===>
(15) ===> ===>
(16) ===> ===>
Press ENTER to process or enter END command to terminate
In the column on the left, type in a DB2 identifier. It can be from one to six characters in length. You may have up to two identifiers with the same name. In addition, you may have up to eight unique DB2 identifiers.
5-10
Enterprise Common Components Installation and Customization Guide
In the column on the right, type in the DB2 dataset names that are required to perform the DB2 precompile step.
For Example:
ID DB2 Precompile Libraries
(1) ===> D610S1 ===> 'SYS1.DSN610.SDSNLOAD'
(2) ===> D610S1 ===> 'SYS1.DSN610.SDSNEXIT'
(3) ===> D710S1 ===> 'SYS1.DSN710.SDSNLOAD'
(4) ===> D710S1 ===> 'SYS1.DSN710.SDSNEXIT'
(5) ===> D810S1 ===> 'SYS1.DSN810.SDSNLOAD'
(6) ===> D810S1 ===> 'SYS1.DSN810.SDSNEXIT'
There are two D610S1 identifiers. That is the maximum for a single identifier. Also, there are three unique identifiers D610S1, D710S1, and D810S1. You may have up to eight of these.
4. Enter CICS IDs and Translator Libraries (Optional)
If your site has CICS, this option will allow you to define CICS identifiers and
associate the identifiers with CICS libraries. See Figure 5-10 and Figure 5-11 below.
When an identifier is selected, the associated datasets will appear in the STEPLIB DD of the translator step and in the SYSLIB DD of the linkedit step. The CICS IDs will
appear on the Compile Menu. See Figure 5-13 on page 5-13.
Figure 5-10. Compile Information Table - Enter CICS IDs and Translator Libraries (1 of 2)
Compuware CSS Utilities --- CICS Translator Libraries -------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: +
These libraries are used in the CICS translator step. The ID is displayed
on the 'Compile Menu'. When the programmer selects one of the IDs from
the 'Compile Menu', the ID is matched to the corresponding library name(s)
that are listed here. You may have up to two libraries with the same ID
name. The 'Compile Menu' can display up to 8 unique IDs.
ID CICS Translator Libraries
(1) ===> ===>
(2) ===> ===>
(3) ===> ===>
(4) ===> ===>
(5) ===> ===>
(6) ===> ===>
(7) ===> ===>
(8) ===> ===>
(9) ===> ===>
(10) ===> ===>
(11) ===> ===>
Press ENTER to process or enter END command to terminate
CSS Customization
5-11
Figure 5-11. Compile Information Table - Enter CICS IDs and Translator Libraries (2 of 2)
Compuware CSS Utilities --- CICS Translator Libraries -------------------------
COMMAND ===>
Use 'Page UP' and 'Page DOWN' to scroll this screen.
More: -
ID CICS Translator Libraries
(1) ===> ===>
(2) ===> ===>
(3) ===> ===>
(4) ===> ===>
(5) ===> ===>
(6) ===> ===>
(7) ===> ===>
(8) ===> ===>
(9) ===> ===>
(10) ===> ===>
(11) ===> ===>
(12) ===> ===>
(13) ===> ===>
(14) ===> ===>
(15) ===> ===>
(16) ===> ===>
Press ENTER to process or enter END command to terminate
In the column on the left, type in a CICS identifier. It can be from one to six characters in length. You may have up to two identifiers with the same name. In addition, you may have up to eight unique CICS identifiers.
In the column on the right, type in the CICS dataset names that are required to perform the CICS translator step.
For example:
ID CICS Translator Libraries
(1) ===> CTS310 ===> 'SYS1.CICS310.LOADLIB1'
(2) ===> CTS310 ===> 'SYS1.CICS310.LOADLIB2'
(3) ===> CTS220 ===> 'SYS1.CICS220.LOADLIB1'
(4) ===> CTS220 ===> 'SYS1.CICS220.LOADLIB2'
(5) ===> CTS210 ===> 'SYS1.CICS210.LOADLIB1'
(6) ===> CTS210 ===> 'SYS1.CICS210.LOADLIB2'
There are two CTS310 identifiers. That is the maximum for a single identifier. Also, there are three unique identifiers CTS310, CTS220, and CTS210. You may have up to eight of these.
5. Enter Miscellaneous Information
There are some options that don't fall under the previously mentioned options.
Those items are found on this screen. See Figure 5-12 on page 5-12.
5-12
Enterprise Common Components Installation and Customization Guide
Figure 5-12. Compile Information Table - Enter Miscellaneous Information
Compuware CSS Utilities ---- Miscellaneous Settings ---------------------------
COMMAND ===>
To prohibit foreground compiles, set the following value to 'N'.
Foreground Compile ===> Y
Job Statement Exit: (Executed before batch job submission)
Exit ===>
The exit syntax uses the ISPF SELECT service syntax.
For example:
Exit ===> CMD(command) or CMD(command) NEWAPPL(applid) PASSLIB
Press ENTER to process or enter END command to terminate
Foreground Compile: Some sites do not want their staff doing foreground compiles.
If you do not want your users doing foreground compiles, then set this field to N.
The Foreground literal will not be displayed as one of the Preparation options. See
Job Statement Exit: This is an exit point in which the JOB card is passed to the stated entity before job submission for the Batch option. The invocation of the exit is also done before the JCL is displayed with the Editjcl option.
The invocation of the exit uses the ISPF SELECT service syntax.
The following are examples:
Exit ===> PANEL(panelid) or PANEL(panelid) NEWAPPL(applid) PASSLIB
Exit ===> CMD(command) or CMD(command) NEWAPPL(applid) PASSLIB
Exit ===> PGM(program-name) or PGM(program-name) PARM(parameters) or
PGM(program-name) PARM(parameters) NEWAPPL(applid) PASSLIB
Note: Batch, Editjcl and Foreground refer to Preparation types on the Compile Menu.
A. Process Options 1 through 5
Entering this option on the command line will cause options 1 through 5 to be displayed sequentially.
C. Copy a Prior Installation's Information to a New Library
The Copy process will take an existing compile information table with member
AAUTCTBL and copy the member to a new compile information table. If the new table already has member AAUTCTBL, a message window appears asking if you want to overwrite the existing member or bypass the update.
This process may be used to create a back-up of your completed compile information table. Also, it may be used to carry existing compile information forward to a new release. Thus, avoiding having to retype the compile information.
Place a C on the command line. In the first field, enter the dataset name that you want to contain the compile information. In the second field, enter the
CSS Customization
5-13
dataset name of an existing compile information table. Hit enter to copy the information.
Later on during the CSS installation, you will need the dataset name of the compile information table.
The Compile Menu is displayed below to assist you in your understanding of how the values that you supply during this installation will affect the display of the Compile
Menu.
Figure 5-13. Compile Facility - Compile Menu
Compuware CSS Utilities -------- Compile Menu ------------------- CSS V8.6.0
COMMAND ===>
Primary Commands: Listing (Display output) SEtup (Display general settings)
Compile Profile: DEFAULT - DEFAULT COMPILE PROFILE
_ Display the Compile Profile list
Source Dsname ===> 'USERID.COB.SOURCE'
Preparation ===> BATCH (Batch/Editjcl/Foreground) <-Opt 5
Language ===> E-COBOL Select From The List Below <-Opt 2
(COB/COB2/COB370/COBMVS/COB390/E-COBOL/CAOPT/HASM/HLASM/PLI/PLI370) <-Opt 1
(VAPLI/E-PLI/CMVS/C390/CZOS)
SEL Options:
D - Display settings S - Select the DB2 Precompile libraries
S - Process only and/or the CICS Translator libraries
SEL STEPS DB2 Precompile CICS Translator
-- ------------------- -------------------- ----------------------
_ 1. DB2 Precompile _ D810S1 _ D710S1 _ CTS31A _ CTS31B <-Opt 3&4
_ 2. CICS Translator _ D610S1 _ D810S2 _ CTS31C _ CTS21A
_ 3. Compile _ D710S2 _ D610S2 _ CTS21B _ CTS21C
_ 4. Linkedit _ D510S1 _ D510S2 _ CTS11A _ CTS11B
Note: The option references refer to the option number on the Install Menu screen.
If you select all of the compilers, this is the list that is generated (option 1). The user will select the language he wants to use for his compile by placing one of the names from the list in the Language field. The name entered tells the compile facility which libraries to use during the compile (option 2).
If you used eight unique DB2 identifiers and libraries, then the DB2 Precompile list will be similar to this list (option 3). If you supplied less than eight unique identifiers, then they will appear in a left to right, top to bottom sequence.
If you used eight unique CICS identifiers and libraries, then the CICS Translator list will be similar to this list (option 4). If you supplied less than eight unique identifiers, then they will appear in a left to right, top to bottom sequence.
If you set the Foreground Compile value to Y, then the Foreground literal appears in the Preparation list (option 5). If you set the value to N, then the literal does not appear.
The following figure shows the Compile Menu with fewer values supplied during installation. In addition, the Foreground Compile option is set to N.
5-14
Enterprise Common Components Installation and Customization Guide
Figure 5-14. Compile Facility - Compile Menu
Compuware CSS Utilities -------- Compile Menu -------------------- CSS V8.3.0
COMMAND ===>
Primary Commands: Listing (Display output) SEtup (Display general settings)
Compile Profile: DEFAULT - DEFAULT COMPILE PROFILE
_ Display the Compile Profile list
Source Dsname ===> 'USERID.COB.SOURCE'
Preparation ===> BATCH (Batch/Editjcl)
Language ===> E-COBOL Select From The List Below
(COB390/E-COBOL/CAOPT/HLASM/VAPLI/E-PLI/C390/CZOS)
SEL Options:
D - Display settings S - Select the DB2 Precompile libraries
S - Process only and/or the CICS Translator libraries
SEL STEPS DB2 Precompile CICS Translator
--- ------------------- -------------------- ---------------------
_ 1. DB2 Precompile _ D810S1 _ D710S1 _ CTS31A _ CTS21A
_ 2. CICS Translator _ D610S1 _ CTS11A
_ 3. Compile
_ 4. Linkedit
CSS Customization
5-15
Step 5. Activate Compuware ISPF Dialogs (Required)
You should perform this step if you plan to use the Compuware Viewing Facility and/or
CSS Utilities.
Note: There is a new Abend-AID viewer that may be used in place of the Compuware
Viewing Facility. While installing Abend-AID release 10.02 or later you will have the option of installing the new viewer to access your Abend-AID reports.
Detailed information on the Abend-AID viewer is available in the Abend-AID
Installation and Customization Guide.
Compuware ISPF dialogs include the Compuware Viewing Facility (Compuware/VF) and
CSS Utilities. This section covers two different ways to activate the Compuware/VF and
CSS Utilities libraries—dynamically, or at TSO startup.
Dynamically allocating the libraries is discussed in Option 1 below. Allocating the
see the Compuware Shared Services User/Reference Guide.
Note: To enable use of the Abend-AID HOTKEY function, you must set up access to
either the REXX EXEC or CLIST listed in Table 5-2 on page 5-16 for the
Compuware/VF. Follow the instructions detailed in this section for their installation and allocation. Further information on the use of the HOTKEY function is available in the Abend-AID Installation and Customization Guide or Abend-
AID User/Reference Guide. The HOTKEY function can only be invoked while Abend-
AID is active, after an abend has occurred, and while it is being displayed on an
ISPF screen.
Option 1 — Dynamically Allocate Libraries when Compuware/VF or CSS
Utilities is Executed
To dynamically allocate the Compuware/VF and CSS Utilities libraries, you must determine how to make the REXX EXECs and CLISTs accessible.
CSS provides sample REXX EXECs and CLISTs for invoking Compuware/VF and CSS
Utilities in SLCXCNTL sample library. You can allocate this library at TSO logon time, or make the CLIST or REXX EXEC accessible in a user-defined library allocated at TSO logon.
IMPORTANT
If CSS REXX EXECs or CLISTs are currently used to invoke the Compuware/VF or CSS utilities, you must replace them with the latest versions in order to use the new
Abend-AID features, Abend-AID for CICS utility features, or the new Compile
Facility. With release 8.3, the Compile Facility has requirements for a new table library and a new skeleton library. Also with release 8.3, the CSS utilities have requirements for the Abend-AID for CICS load library when use with CICS type
DDIO files is anticipated.
If the current Abend-AID load and customization libraries are not available in the link list or through your TSO logon PROC or CLIST, they must be dynamically allocated from Compuware/VF REXX EXEC or CLIST. This will prevent text merge and CWROUTE errors during view-time.
Complete the following steps:
1. Determine whether to use REXX EXECs or CLISTs.
Compuware recommends using REXX EXECs; you may find them easier to customize and maintain.
5-16
Enterprise Common Components Installation and Customization Guide
2. Determine whether Japanese and English language support is required, or just
English language support.
3. If using REXX EXECs, choose the appropriate REXX EXEC for Compuware/VF and
the appropriate REXX EXEC for CSS Utilities using Table 5-2 as a guide. If using
CLISTs, select one CLIST for Compuware/VF and one CLIST for CSS Utilities.
4. Change the library names in the REXX EXECs or CLISTs selected in Step 3 to match your site standards.
Note: Effective with CSS Release 8.1, an optional ISPSLIB can be used with On-the-Fly processing. See Appendix D in the Compuware Shared Services User/Reference Guide for details about On-the-Fly processing. You may use an existing skeleton library allocated at TSO logon time, or allocate one at viewer startup by updating the
REXX EXECs or CLISTs selected in “Step 3. Make New CSS Load Modules
Accessible to Compuware Products (Required)” on page 5-4.
Note: Effective with CSS Release 8.3, the online compile facility of the Compuware
Viewing Facility and the CSS Online Utilities require the SLCXSLIB and
SLCXTABL datasets to be concatenated to ISPSLIB and ISPTLIB respectively. The
SLCXTABL dataset was created in “Step 4. Create the Compile Information Table
Table 5-2.
REXX EXECs or CLISTs Used to Invoke Compuware/VF and/or CSS utilities
Use this REXX EXEC Or this CLIST For
CWVFREXE
CWVFREXJ
CWUTREXE
CWUTREXJ
CWVFCLSE
CWVFCLSJ
CWUTCLSE
CWUTCLSJ
Compuware/VF, English-only language support, view Abend-AID reports or run utilities
Compuware/VF, English and Japanese language support, view
Abend-AID reports or run utilities
CSS Utilities, English-only language support, set up or run
XPEDITER utilities
CSS Utilities, English and Japanese language support, set up or run XPEDITER utilities
Note: When testing a new install of Abend-AID, if the new Abend-AID load and customization libraries have not yet been placed in the link list, they must be included in CWVFREXE or CWVFCLSE (and/or the Japanese versions) under the ISPLLIB concatenation. Doing this will prevent text merge error messages when viewing an Abend-AID report.
5. Allocate the CSS SLCXCNTL library at TSO logon time, or copy the edited REXX
EXECs/CLISTs to a library allocated at TSO logon:
– To allocate the CSS SLCXCNTL library at TSO logon
Add the library to the SYSPROC concatenation in the TSO logon PROC.
– To make specific REXX EXECs/CLISTs accessible in a library allocated at TSO
logon
Copy the REXX EXECs or CLISTs to an existing SYSPROC library allocated at TSO logon.
6. The sample REXX EXECs (CWVFREXE, CWVFREXJ) and CLISTs (CWVFCLSE,
CWVFCLSJ) invoke the Compuware Viewing Facility. All of them accept an optional parameter that specifies one of the options from the Abend-AID primary menu. To bypass the primary menu and directly access a menu option, enter one of the following:
TSO %CWVFREXE section-id
TSO %CWVFCLSE SECT(section-id)
where, section-id is one of the options from the Abend-AID primary menu.
CSS Customization
5-17
Note: The Abend-AID primary menu displays, if you do not enter a section-id.
Following is a list of valid section-ids:
• 1 (VIEW)
• 2 (CREATEJCL)
• 3 (SOURCE)
• 4 (AAREPORT)
• 5 (CONTACTS)
• L (LP)
• D (DDIO)
• C (LEGAL)
Refer to the “Compuware Viewing Facility” chapter in the Compuware Shared Services
User/Reference Guide for more information on these options.
7. Users can invoke either Compuware/VF or CSS Utilities by selecting an option from an ISPF panel (recommended), or by executing a REXX EXEC or CLIST.
– To enable users to select an ISPF menu option
Add one or more of the following lines to an ISPF panel. Note that ‘o’ represents the option to be entered at the menu command prompt.
To invoke Compuware/VF o,'CMD (%
Compuware/VF CLIST name
or
Compuware/VF REXX
EXEC name
)
To invoke CSS Utilities o,'CMD (%
CSS Utilities CLIST name
or
CSS Utilities REXX EXEC name
)
– To invoke Compuware/VF or CSS Utilities by executing a REXX EXEC or
CLIST
Enter the appropriate command at the TSO command prompt:
To invoke Compuware/VF
TSO %
Compuware/VF CLIST name
or
Compuware/VF REXX EXEC name
To invoke CSS Utilities TSO %
CSS Utilities CLIST name
or
CSS Utilities REXX EXEC name
Option 2 — Allocate the Libraries at TSO Startup
Allocating the load, panel, and message libraries at TSO logon simplifies maintenance.
All TSO users have access to Compuware/VF and CSS Utilities after logging on to TSO, and upgrades that affect all TSO users can be made in one central location. Allocating these libraries at TSO logon may be inappropriate, however. In that case, dynamically allocating the libraries may be a better solution.
To provide access to the load, panel, and message modules at TSO logon time, complete the following steps.
5-18
Enterprise Common Components Installation and Customization Guide
1. Concatenate each library as shown in Table 5-3:
Table 5-3.
Allocating CSS Libraries
Place the CSS load library in the link list (see “Step 3. Make New CSS Load Modules
Accessible to Compuware Products (Required)” on page 5-4 for instructions)
Load library
SLCXLOAD
OR
Place a DD statement for the load library in the concatenation for STEPLIB or ISPLLIB in your TSO logon PROC
OR
Execute a CLIST or REXX EXEC at logon time that will concatenate the load library to the appropriate DD statement before starting ISPF
Place the HCI load library in the link list (see “Step 3. Make New CSS Load Modules
Accessible to Compuware Products (Required)” on page 5-4 for instructions)
OR
Load library
SLHCLOAD Place a DD statement for the load library in the concatenation for STEPLIB or ISPLLIB in your TSO logon PROC
HCI — required for Abend-AID or
Abend-AID for
CICS
OR
Execute a CLIST or REXX EXEC at logon time that will concatenate the load library to the appropriate DD statement before starting ISPF
Note: Abend-AID for CICS users must place a DD statement for the load library in the concatenation for FDBDRPL in your server startup JCL.
Concatenate the library to ISPMLIB in the TSO logon PROC
Message library
SLCXMENU
OR
Concatenate the library to ISPMLIB in a CLIST or REXX EXEC before starting ISPF
Concatenate the library to ISPPLIB in the TSO logon PROC
Panel library
SLCXPENU
OR
Concatenate the library to ISPPLIB in a CLIST or REXX EXEC before starting ISPF
Concatenate the library to SYSPROC in the TSO logon PROC
EXEC library
SLCXEXEC
OR
Concatenate the library to SYSPROC in a CLIST or REXX EXEC before starting ISPF
Due to the Compile Facility's requirement for this library, as of CSS release 8.3, this DD is required.
Concatenate the library to ISPSLIB in the TSO logon PROC
Skeleton Library
SLCXSENU
OR
Concatenate the library to ISPSLIB in a CLIST or REXX EXEC before starting ISPF.
Optional - concatenate the library for On-the-Fly processing. See Appendix D in the
Compuware Shared Services User/Reference Guide for details.
Concatenate the library to ISPTLIB in the TSO logon PROC
Table Library
SLCXTABL
OR
Concatenate the library to ISPTLIB in a CLIST or REXX EXEC before starting ISPF.
Note: This file is created in “Step 4. Create the Compile Information
Table (Required)” on page 5-5.
CSS Customization
5-19
Notes:
a. Replace any existing CSS libraries in these concatenations.
b. The low level qualifiers are listed below their respective library names.
c. When testing a new install of Abend-AID, if the new Abend-AID load and customization libraries have not yet been placed in the link list, they must be added as explained in the instructions for the SLCXLOAD library. Doing this will prevent text merge error messages when viewing an Abend-AID report.
d. When testing a new install of Abend-AID for CICS, if the new Abend-AID for
CICS load library has not yet been placed in the link list, it must be added as explained in the instructions for the SLCXLOAD library. Doing this will prevent error messages when using the CSS Utilities with Abend-AID for CICS DDIO files.
2. Add one or more of the following lines to an ISPF panel. Note that ‘o’ represents the option to be entered at the ISPF menu command prompt.
To invoke Compuware/VF
To invoke CSS Utilities o,'PGM(CWDDSUTL) NEWAPPL(AAUT) PARM(SPF)' o,'PGM(CWDDIUFE) NEWAPPL(AAUT)'
Step 6. Link Compuware/VF and CSS Utilities Tutorials to Your Main Tutorial Panel (Optional)
CSS SLCXCNTL sample library contains two sample tutorial main menu panels for ISPF and ISPF/PDF:
• CXTUTOR
• CXR00003
To link the Compuware/VF and CSS Utilities tutorial panels to your tutorial main menu panel (TTUTOR or ISR00003), use the applicable member as an example.
5-20
Enterprise Common Components Installation and Customization Guide
Step 7. Associate Contact Information File with
Compuware/VF (Optional)
The Contact Information feature enables Compuware/VF users to associate contact information (for example, the phone number and e-mail address of an off-duty programmer) with a particular job name. In order to use this feature, the contact information file must be associated with Compuware/VF.
Complete the following steps:
1. Use the following members from the CSS SLCXCNTL sample library:
– CXCIVSAM
– CXCIREG
2. Edit member CXCIVSAM and modify the COMPWARE.CONTACT.INFO dataset name to conform to your installation’s naming standards.
3. Execute CXCIVSAM to allocate the VSAM dataset that will store contact information.
4. Edit member CXCIREG and change the CDSN symbolic parameter to the dataset name used in Step 2.
5. Set the CXLOAD symbolic parameter to the CSS load library dataset name.
6. Set the CXCNTL symbolic parameter to the CSS SLCXCNTL sample JCL dataset name.
7. (Optional) Specify the UNIT and ASSEMBLER symbolic parameters.
8. Execute CXCIREG to register the contact information dataset.
9. To populate the Contact Information file, refer to the Compuware Shared Services
User/Reference Guide “Working with Contact Information” section in the Compuware
Viewing Facility chapter.
If you wish to use a Contact Information dataset created prior to CSS 7.8 (PTF level
CXF0168), it must be converted into the new extended format. The CSS SLCXCNTL sample library contains the CXCIVSAM and CXCICONV members.
1. Edit the CXCIVSAM member and change the dataset name to a new name. Execute the job.
2. Edit the CXCICONV member. Change the CIDSN symbolic parameter to point to the original contact information dataset.
3. Change the CODSN symbolic parameter to point to the new dataset you just allocated.
4. Execute CXCICONV. Follow the instructions for step 9 above and adjust the Contact
Information data if necessary.
CSS Customization
5-21
Step 8. Establish Access to File-AID (Optional)
File-AID users may now access File-AID/MVS, File-AID for DB2, or File-AID for IMS directly from the appropriate Abend-AID report sections by using simple line commands within the Compuware/VF. Installation requirements for each version of File-AID are listed below. Abend-AID release 9.1 or higher must also be installed.
File-AID/MVS Users
To access File-AID/MVS from the Compuware/VF Output Selection Menu Option 8, complete the following steps:
1. Ensure that a supported version of File-AID/MVS is installed.
2. Either:
– Allocate the File-AID/MVS libraries at TSO logon
OR
– Locate the CWVFCLSE CLIST or CWVFREXE REXX EXEC in the SLCXCNTL sample library. Uncomment the lines labeled FA/MVS PANEL LIB, FA/MVS
MESSAGE, FA/MVS LOADLIB, and FA/MVS LOADLIB and replace the existing library names with your actual File-AID/MVS library names.
File-AID for DB2 Users
To access File-AID for DB2 from the Compuware/VF Output Selection Menu Option 11, complete the following steps:
1. Ensure that a supported version of File-AID for DB2 is installed.
2. Locate the CWVFDB2 and FDXTRN01 CLISTs in the SLCXCNTL sample library.
3. Move these CLISTs to a library allocated at TSO logon.
If Compuware/VF is started by executing CWVFCLSE or CWVFREXE you can place these CLISTs into the SLCXEXEC library.
4. Locate the following line in CLIST CWVFDB2:
/* SET &FADB2CL = '????????.FADB2.ISRCLIB'
Replace this dataset name with the name of the File-AID for DB2 CLIST library.
5. (Optional) To dynamically allocate the File-AID for DB2 ISPF and CLIST libraries when a user accesses File-AID from Compuware/VF, set the LIBDEF PROC variable in
CLIST CWVFDB2 to Y.
File-AID for IMS Users
To access File-AID for IMS from the Compuware/VF Output Selection Menu Option 9, the following conditions must be met:
• A supported version of File-AID for IMS must be installed.
• File-AID for IMS CLISTs FIALLOC and FIFREE must exist in a CLIST allocated to the user’s SYSPROC DD.
Note: If any File-AID error messages are received within the Compuware/VF while viewing any of the sections listed above, and access to the required File-AID libraries has been set up properly, please contact your File-AID support representative.
5-22
Enterprise Common Components Installation and Customization Guide
Step 9. Prepare the DDIO Files
You must perform this step if you are a new CSS user or have never created DDIO
files and now need to use them. If you are an Abend-AID user you will need to allocate a Report Shared Directory and one or more Report databases.
CSS DDIO files are used to store Abend-AID reports, transaction dump information, and source listings. The term DDIO file is a generic term used to refer to the datasets that store the reports and listings from Compuware Products that use CSS. This step describes the various types of DDIO files available and who needs to allocate which type.
Types of DDIO Files
There are two main categories of DDIO files: report or source listing files and report or source listing databases which are grouped into pools that are attached to Shared
Directories. CSS uses the Shared Directory architecture to manage the available pool space.
Within these two categories of DDIO files, there are three different types of DDIO files characterized by the type of information that is stored in them: Abend-AID reports, source listings, and CICS transaction dump information.
Note: If you use the Shared Directory architecture for your DDIO files, different database types cannot be attached to the same Shared Directory (for example, you cannot attach a source listing database to a report shared directory, and vice versa). Starting with CSS release 8.3, you can now attach transaction databases and report databases to the same Shared Directory.
Note: Non-database report or source listing files cannot be attached to a Shared
Directory until they have been converted using the batch utility CONVERT command in CWDDALLU, or CWAASDUT (report only) and CWDDLPUT (source listing only). See the “Batch File Utility” chapters in the Compuware Shared Services
User/Reference Guide for more information, specifically Chapter 8 "Batch File
Utility CWDDALLU" for detailed command and parameter descriptions.
1. Abend Reports: a. Report Shared Directories and Databases. This type of file is used to store abend reports created by Abend-AID. This Report Shared Directory architecture is only
supported for Abend-AID Release 9.4 and later. Report databases are attached to a report shared directory. The report databases are managed as a POOL of space belonging to the report shared directory to which they are attached.
b. Report DDIO files. This type of DDIO file is used to store Abend Reports created by Abend-AID. Prior to Abend-AID Release 9.4, this was the only type of report file available. For compatibility purposes, Abend-AID Release 9.4 can also use this type of report file. A conversion utility is available to run when the user is ready to migrate the report file to the report database format.
2. Source Listings: a. Source Listing Shared Directories and Databases. This type of DDIO file is used to store compiler source listings for use by various Compuware Products. Source listing databases are attached to a source listing shared directory. The source listing databases are managed as a POOL of space belonging to the source listing shared directory to which they are attached. The Source Listing Shared Directory
architecture can now be used with all supported language compilers. However, XPEDITER
users should see notes and exceptions below.
b. Source Listing DDIO Files. This type of DDIO file is used to store compiler source listings. A conversion utility is available to run when the user is ready to migrate the listing file to the source listing database format.
CSS Customization
5-23
The same source listing file, database, or source listing member can be used by multiple
Compuware Products. It is not necessary to create duplicate source listing files, databases, or source listing members for each Compuware Product.
3. Transaction Databases and Shared Directory for Abend-AID for CICS. Transaction databases are used by Abend-AID for CICS to store CICS transaction dump information. Abend-AID for CICS catalogs both CICS transaction dumps and imported Region Dumps into the shared directory.
The following table lists the types of DDIO files created by the CSS utilities and which products use/require them:
Table 5-4.
DDIO File Formats
Compuware Product
Report
File
Source
Listing File
Transaction
Databases &
Shared Dir.
Abend-AID
Abend-AID for CICS x x x x
Xpediter/TSO
Xpediter/IMS
Xpediter/CICS
Xpediter/Eclipse
Strobe x x x x x
Report
Shared Dir.
& Database
x
Source
Listing
Shared Dir.
x x x
1
See Note x
1
See Note
See Note
See Note
Source
Listing
Database
x x x x x x
1
If using Xpediter/TSO and /IMS with the C Language Processor, VisualAge PL/I, or Enterprise PL/I, and you use Long Program Names, the Source Listing Shared Directory must be used.
Refer to the “Source Listing Databases and Shared Directories” section of Chapter 2 in the
Compuware Shared Services User/Reference Guide for more information.
File Access Methods
You may use either sequential or VSAM files for DDIO files. Shared directories must be
VSAM files. If you are using VSAM files for your DDIO files, you can copy them using the
IDCAMS REPRO command. You cannot, however, change any of the file attributes such as CISIZE without reallocating a DDIO/DB file. Allocation and format requirements, along with the steps for preparing the various DDIO files, will vary according to the type of file. Source listing files can be shared between all Compuware products that use CSS, while report files, transaction databases, work files, and profile files, cannot. Source listing files used by XPEDITER/CICS must be VSAM.
CAUTION:
CWDDSUTL, CWFXSDUT, CWAASDUT, CWDDLPUT, and CWDDALLU are the only utilities recommended for use with Compuware DDIO files.
File-AID/MVS and other VSAM-related vendor products (including vendor packages that compress or enhance buffer management on VSAM files) should NOT be used against Compuware DDIO files. Doing so can result in corrupting the contents of the
DDIO file. Refer to “Chapter 2. Allocating and Formatting DDIO Files” in the
Compuware Shared Services User/Reference Guide for more information.
5-24
Enterprise Common Components Installation and Customization Guide
Step 9a. Allocate and Format Abend-AID Report Shared Directories and
Databases for Abend-AID Release 9.4 and Later Users
This step should only be performed by Abend-AID users who have installed, are installing, or are migrating to Abend-AID Release 9.4 or later. The purpose of this step is to allocate and format a Report Shared Directory and one or more Report Databases attached to that Shared Directory. Note that Abend-AID 9.4 is the minimum release able to use these types of DDIO file.
Typically, this step would be performed during Abend-AID release 9.4 or later installation. For more information, see the Abend-AID Installation and Customization Guide.
The CSS online utilities can be used to allocate and format Abend-AID report DDIO files.
Refer to “Chapter 3. CSS Utilities” in the Compuware Shared Services User/Reference Guide for more information.
Create the Report Shared Directory
Use the sample JCL in the CSS SLCXCNTL dataset to allocate and format the Report
Shared Directory (member is CXALLDAA). For additional options refer to the "Batch File
Utility CWDDALLU" chapter in the Compuware Shared Services User/Reference Guide. The shared directory CREATE command will both ALLOCATE and FORMAT the shared directory. If the file currently exists, you must specify parameter REALLOCATE=YES or the allocate will fail with a duplicate file error.
Create the Report Databases
You must have already created the Report Shared Directory before attempting to create the Report Database. You can create both in the same job as long as the Report Shared
Directory create is done first. The database CREATE command will both ALLOCATE and
FORMAT the database. If the file currently exists, you must specify parameter
REALLOCATE=YES or the allocate will fail with a duplicate file error.
VSAM Report Databases can be created using the sample JCL in the CSS SLCXCNTL dataset (member is CXALLVAA). To allocate and create a database that spans multivolumes, use member CXDCRADB. To create a report shared directory in the same job, use member CXDCRASD.
Sequential Report Databases can be created using the sample JCL in the CSS SLCXCNTL dataset (member is CXALLBAA).
Step 9b. Allocate and Format Abend-AID Report Files for Pre-Abend-
AID Release 9.4 Users
You must perform this step if you are an Abend-AID user and did not perform “Step 9a.
Allocate and Format Abend-AID Report Shared Directories and Databases for Abend-AID
Release 9.4 and Later Users”, and do not have an existing Report File.
Allocate the Report Files
VSAM Report files can be allocated using the sample JCL in the CSS SLCXCNTL dataset member CXALLVS. To allocate and format a report DDIO file that spans multi-volumes, use member CXDFMAA.
Sequential Report files can be allocated using the sample JCL in the CSS SLCXCNTL dataset member CXALLDS.
CSS Customization
5-25
Format the Report Files
After the report files have been allocated, they must be formatted before they can be used. The formatting process initializes the directory structure and specifies the file options.
CSS SLCXCNTL library member CXFMTAA contains sample JCL to format a report file with appropriate defaults for the sample files allocated using members CXALLVS or
CXALLDS. Adjust the formatting parameters to meet your DDIO file needs. Do not execute the CXFMTAA member, if you have already run the CXDFMAA job.
Step 9c. Allocate and Format Source Listing Shared Directories and
Databases
This step may be performed by all users who use Source Listing support. However, releases prior to XPEDITER/TSO 7.3, XPEDITER/CICS 7.6, and Abend-AID for CICS 4.5 do not support Source Listing Shared Directories. Instead, individual source databases may be specified for lower levels. Source Listing Databases used by XPEDITER/CICS must be
VSAM.
The CSS online utilities can be used to allocate and format source listing DDIO files. Refer to “Chapter 3. CSS Utilities” in the Compuware Shared Services User/Reference Guide for more information.
Create the Source Listing Shared Directory.
Use the sample JCL in the CSS SLCXCNTL dataset to allocate and format the Source
Listing Shared Directory (member is CXALLDLP). For additional options refer to the
"Batch File Utility CWDDALLU" chapter in the Compuware Shared Services User/Reference
Guide. The shared directory CREATE command will both ALLOCATE and FORMAT the shared directory. If the file currently exists, you must specify parameter
REALLOCATE=YES or the allocate will fail with a duplicate file error.
Create the Source Listing Databases
You must have already created the Source Listing Shared Directory before attempting to create the Source Listing Database. You can create both in the same job as long as the
Source Listing Shared Directory create is done first. The database CREATE command will both ALLOCATE and FORMAT the database. If the file currently exists, you must specify parameter REALLOCATE=YES or the allocate will fail with a duplicate file error.
VSAM Source Listing Databases can be created using the sample JCL in the CSS
SLCXCNTL dataset (member is CXALLVLP). To allocate and create a database that spans multi-volumes, use member CXDCRLDB. To create a source shared directory in the same job, use member CXDCRLSD.
Sequential Source Listing Databases can be created using the sample JCL in the CSS
SLCXCNTL dataset (member is CXALLBLP).
Step 9d. Allocate and Format Source Listing Files
You must perform this step if you did not perform “Step 9c. Allocate and Format Source
Listing Shared Directories and Databases” and you do not have an existing source listing
file or database. Source listing files used by XPEDITER/CICS must be VSAM.
Allocate the Source Listing Files
VSAM Source Listing files can be allocated using the sample JCL in the CSS SLCXCNTL dataset member CXALLVS. To allocate and format a source DDIO file that spans multivolumes, use member CXDFMSL).
5-26
Enterprise Common Components Installation and Customization Guide
Sequential Source Listing files can be allocated using the sample JCL in the CSS
SLCXCNTL dataset member CXALLDS.
Format the Source Listing Files
After the source listing files have been allocated, they must be formatted before they can be used. The formatting process initializes the directory structure and specifies the file options.
CSS SLCXCNTL library member CXFMTSL contains sample JCL to format a source listing file with appropriate defaults for the sample files allocated using members CXALLVS or
CXALLDS. Adjust the formatting parameters to meet your DDIO file needs. Do not execute the CXFMTSL member, if you have already run the CXDFMSL job.
Step 9e. Allocate and Format Abend-AID for CICS Shared Directories and Transaction Databases
Normally this would be performed during the Abend-AID for CICS install procedure. For additional information, see the Abend-AID for CICS Installation and Customization Guide.
Create Abend-AID for CICS Shared Directory (Allocate & Format)
Use the sample JCL to create the shared directory. CSS SLCXCNTL sample library member
CXALLMC contains the sample JCL for creating a Abend-AID for CICS shared directory.
Create Abend-AID for CICS Transaction Database (Allocate & Format)
You must create the shared directory before proceeding to this step. Use one of the following two sets of sample JCL to create each Abend-AID for CICS database as needed:
VSAM Abend-AID for CICS Database: CSS SLCXCNTL sample library member
CXALLVSD contains sample JCL for creating a Abend-AID for CICS VSAM transaction database. To allocate and create a database that spans multi-volumes, use member
CXDCRTDB. To create an Abend-AID for CICS shared directory in the same job, use member CXDCRTSD.
Sequential Abend-AID for CICS Database: CSS SLCXCNTL sample library member
CXALLBSD contains sample JCL for creating a Abend-AID for CICS sequential transaction database.
CSS Customization
5-27
Step 10. Implement the Language Processor JCL
(Required)
See the sub-steps below to determine when you must perform this step.
The language processors support two methods of processing your programs: preprocessing and postprocessing. Both of these choices may involve modifications to your compile JCL.
You may use the preprocessor or postprocessor (whichever is best for your site as needed.)
This section discusses the benefits of the preprocessor and the postprocessor and describes when to use them. See the Compuware Shared Services User/Reference Guide for more information on determining when to use the pre- or postprocessor.
Refer to “CSS Language Processor (LP)” on page 2-6 for descriptions of preprocessing and
postprocessing and a summary of the benefits provided by each method.
To use the language processor, you must have previously completed installation of the
CSS load library and also prepared a DDIO file. For each language you are using, you should modify the corresponding compiler procedure to provide for the type of processing you will be implementing.
When running the language processor as a preprocessor, you can specify assembler/compiler options in the CWPPRMO dataset or in the PARM statement passed to the preprocessor. The CWPPRMO is an input dataset that contains the language processor compiler options. Depending on the method used, it may be necessary to include the LANGPARM command with these options.
If you are currently using the postprocessor, and you will be converting to the preprocessor, you are not required to spool your SYSPRINT to a temporary dataset.
Note: For each of the following steps, it is possible that you will receive a return code other than zero. Should this occur, note the accompanying language processor error message and refer to the Enterprise Common Components Messages and Codes guide for further information.
Step 10a. Modify the JCL to Run the COBOL Language Processor
You must perform this step if either of the following is true:
• You are installing XPEDITER/CICS for the first time.
• You are installing Abend-AID for the first time or you are upgrading a current Abend-
AID installation with Abend-AID source support and you are licensed for the
Compuware COBOL language processor.
You may optionally perform this step if you are installing Abend-AID for CICS or
XPEDITER/TSO and you are licensed for the Compuware COBOL language processor.
XPEDITER/TSO customers can either perform this step now in batch mode, or online as part of the XPEDITER/TSO installation procedure.
This step contains instructions for both the COBOL language preprocessor and postprocessor. You should follow the instructions that apply to the type of processing you will be performing.
Preprocessor
SLCXCNTL sample library member CXCOBPRE contains sample JCL necessary to run the
COBOL language preprocessor.
Modify the compile step of your COBOL JCL:
5-28
Enterprise Common Components Installation and Customization Guide
• On the EXEC statement, change the name of your compiler to CWPCMAIN and add the following to any existing COBOL compiler options:
LANGUAGE(compiler version)
Notes:
a. The LANGUAGE command may be specified in the CWPPRMO command stream rather than on the EXEC statement.
b. The preprocessor accepts VSCOBOLII, VSCOBOLIIREL3, VSCOBOLIIREL4,
COBOL/370, COBOL/390, COBOL/MVS, and COBOLZ/OS as being equivalent because the program name is the same. The compiler that is actually executed depends on the library specified in the STEPLIB, JOBLIB, and/or LINKLIST concatenation.
• Add the CSS SLCXLOAD DSN to the STEPLIB or JOBLIB concatenation if it is not in the link list.
• Add the CWPDDIO DD statement to specify the name of the source listing DDIO file you will be using. The source listing DDIO file may be in standard DDIO, shared directory, or database format. Releases prior to XPEDITER/TSO 7.3, XPEDITER/CICS
7.6, and Abend-AID for CICS 4.5 do not support source listing shared directories.
Instead, individual source databases may be specified for lower levels.
Note: If the source member is to be used by XPEDITER/CICS, the source listing file specified here must be VSAM.
• Determine the language processor options you will use as input and add them to the
EXEC parameter, or add a CWPPRMO DD statement that points to the appropriate options. Sample options are contained in SLCXCNTL sample library members
CXLPCOBB (for batch programs) and CXLPCOBC (for CICS programs) to provide the smallest output to the source listing file (for minimizing space) and generate a printout of the COBOL enhanced listing. When using these options, a printout of the listing from the DDIO file contains only the source statements. The XREF and other portions of the listing are not written to the DDIO file. If you use the sample options, note the following:
– If you do not have XPEDITER/TSO, remove DDIO(OUTPUT(FIND)).
– If the program will be used by XPEDITER/CICS or Abend-AID for CICS, use the options in sample CXLPCOBC.
• The SYSPRINT file will be LRECL=133, RECFM=FBA.
Postprocessor
You can use the postprocessor to process compile listings that were previously stored, or you can modify your COBOL compile JCL to pass the compiler listing to the postprocessor as described below.
• Check the COBOL compiler options.
• Change the COBOL compiler JCL to write the compiler listing (SYSPRINT) to a sequential file that can be used as input to the COBOL language postprocessor. A sample of the necessary JCL is shown below.
//SYSPRINT DD UNIT=SYSDA,SPACE=(TRK,(25,20)),DCB=BLKSIZE=16093,
// DISP=(MOD,PASS) <===== CA-OPTIMIZER NEEDS 'MOD'
The above example is a temporary file. You can save the JCL as a permanent file to be reused as shown in the example below:
//SYSPRINT DD DSN=CX,STORED.LISTINGS(MEMBER)
CSS Customization
5-29
• The SYSPRINT file will be LRECL=133, RECFM=FBA.
• Add SLCXCNTL sample library member CXCOB1 as the postprocessor step following your COBOL compile step.
• Determine the language processor options you will use as input and add them to the
EXEC parameter, or add a CWPPRMO DD statement that points to the appropriate options. Sample options are contained in SLCXCNTL sample library members
CXLPCOBB (for batch programs) and CXLPCOBC (for CICS programs) to provide the smallest output to the source listing file (for minimizing space) and generate a printout of the COBOL listing. When using these options, a printout of the listing from the DDIO file will contain only the source statements. The XREF and other portions of the listing will not be written to the DDIO file. If you use the sample options, note the following:
– If you do not have XPEDITER/TSO, remove DDIO(OUTPUT(FIND)).
– If the program will be used by XPEDITER/CICS or Abend-AID for CICS, use the options in sample CXLPCOBC.
The SLCXCNTL sample library members that are supplied for the COBOL language postprocessor invoke the language processor in different ways:
Table 5-5.
SLCXCNTL Sample Library Members for COBOL Language Processor
Member Purpose
CXCOB1
CXCOB2
Processes compiler listings through the language postprocessor. Add this JCL after your
COBOL compile step and before your link edit step (if one exists).
Postprocesses compiler listings stored from a previous compile job. Use this JCL to process listings that have been previously compiled and stored in machine-readable format.
CXCOB99 Compiles COBOL programs and feeds the compiler output into the COBOL postprocessor.
• The CWPPRTO file will be LRECL=133, RECFM=FBA.
• The CWPLOAD file must be allocated using DISP=OLD or DISP=SHR.
• The object module that is processed by the postprocessor must be used as input to the linkedit step.
Step 10b. Modify the JCL to Run the PL/I Language Processor
You must perform this step if the following is true:
• You are installing Abend-AID with Compuware/VF, or XPEDITER/CICS, or
XPEDITER/TSO and you are licensed for the Compuware PL/I language processor.
This step contains instructions for both the PL/I language preprocessor and postprocessor. You should follow the instructions that apply to the type of processing you will be performing.
Preprocessor
SLCXCNTL sample library member CXPLIPRE contains sample JCL necessary to run the
PL/I language preprocessor.
Modify the compile step of your PL/I JCL:
• On the EXEC statement, change the name of your compiler to CWPPMAIN and add the following to any existing PL/I compiler options:
LANGUAGE(compiler version)
Refer to the Compuware Shared Services User/Reference Guide for a list of the compiler versions that can be specified with the LANGUAGE command. The default compiler for PL/I is the compiler currently in use on your system.
5-30
Enterprise Common Components Installation and Customization Guide
Note: The LANGUAGE command may be specified in the CWPPRMO command stream rather than on the EXEC statement.
• Add the CSS SLCXLOAD DSN to the STEPLIB or JOBLIB concatenation if it is not in the link list.
• Add the CWPDDIO DD statement to specify the name of the source listing DDIO file you will be using. The source listing DDIO file may be in standard DDIO, shared directory, or database format. Releases prior to XPEDITER/TSO 7.3, XPEDITER/CICS
7.6, and Abend-AID for CICS 4.5 do not support source listing shared directories.
Instead, individual source databases may be specified for lower levels.
Note: If the source member is to be used by XPEDITER/CICS, the source listing file specified here must be VSAM.
• Determine the language processor options you will use as input and add them to the
EXEC parameter, or add a CWPPRMO DD statement that points to the appropriate options. Sample options are contained in SLCXCNTL sample library member
CXLPPLI to provide the smallest output to the source listing file (for minimizing space). If you use these options, and you will be using the PL/I language preprocessor, add LANGUAGE(xxx) to the EXEC PARM or to the CWPPRMO DD statement.
See the Compuware Shared Services User/Reference Guide for more information on this JCL and
PL/I language processor options.
Postprocessor
You can use the postprocessor to process compile listings that were previously stored, or you can modify your PL/I compile JCL to pass the compiler listing to the postprocessor as described below.
• Check the PL/I compiler options.
• Change the PL/I compile JCL to write the compiler listing (SYSPRINT) to a sequential file for use as input to the PL/I language postprocessor. A sample of the necessary JCL is shown below.
//SYSPRINT DD UNIT=SYSDA,SPACE=(CYL,(100,10)),DCB=BLKSIZE=19069,
// DISP=(MOD,PASS)
The above example is a temporary file. You can save the JCL as a permanent file to be reused as shown in the example below:
//SYSPRINT DD DSN=CX,STORED.LISTINGS(MEMBER)
• The SYSPRINT file will be LRECL=133, RECFM=FBA.
Table 5-6.
SLCXCNTL Sample Library Members for PL/I Language Processor
Member Purpose
CXPLI
Processes compiler listings through the language postprocessor. Add this JCL after your PL/I compile step and before your link edit step (if one exists). CXPLI can be customized to meet your site’s requirements.
CXPLI2
Postprocesses compiler listings stored from a previous compile job. Use this JCL to process listings that have been previously compiled and stored in machine-readable format.
• The CWPLOAD file must be allocated using DISP=OLD or DISP=SHR.
• The object module that is processed by the postprocessor must be used as input to the linkedit step.
CSS Customization
5-31
See the Compuware Shared Services User/Reference Guide for more information on this JCL and
PL/I language processor options.
Step 10c. Modify the JCL to Run the Assembler Language Processor
You must perform this step if you are licensed for the Assembler language processor option for any product.
You can optionally perform this step if you are installing XPEDITER/TSO and you are licensed for the Compuware Assembler language processor. XPEDITER/TSO customers can either perform this step now in batch mode, or online as part of the XPEDITER/TSO installation procedure.
This step contains instructions for both the Assembler language preprocessor and postprocessor. You should follow the instructions that apply to the type of processing you will be performing.
SLCXCNTL sample library member CXASMPRE contains sample JCL necessary to run the
Assembler language preprocessor.
Preprocessor
Modify the assembly step of your Assembler JCL:
• On the EXEC statement, change the name of your compiler to CWPAMAIN and add the following to any existing assembler options:
LANGUAGE(assembler version)
Refer to the Compuware Shared Services User/Reference Guide for a list of the assembler versions that can be specified with the LANGUAGE command. The default assembler is Assembler H.
Note: The LANGUAGE command may be specified in the CWPPRMO command stream rather than on the EXEC statement.
• Add the CSS SLCXLOAD DSN to the STEPLIB or JOBLIB concatenation if it is not in the link list.
• Add the CWPDDIO DD statement to specify the name of the source listing DDIO file you will be using. The source listing DDIO file may be in standard DDIO, shared directory, or database format. Releases prior to XPEDITER/TSO 7.3, XPEDITER/CICS
7.6, and Abend-AID for CICS 4.5 do not support source listing shared directories.
Instead, individual source databases may be specified for lower levels.
Note: If the source member is to be used by XPEDITER/CICS, the source listing file specified here must be VSAM.
• Determine the language processor options you will use as input and add them to the
EXEC parameter, or add a CWPPRMO DD statement that points to the appropriate options. Sample options are contained in SLCXCNTL sample library member
CXLPASM to provide the smallest output to the source listing file (for minimizing space). When using these parameters, a printout of the listing from the DDIO file will contain only the source statements. The XREF will not be written to the DDIO file. If you use these options and you will use the Assembler language preprocessor, add
LANGUAGE(xxx) to the EXEC PARM or to the CWPPRMO DD statement.
• Specify the compiler (and release) you will use by including it as a parameter of the
LANGUAGE command in your EXECUTE parameter or CWPPRMO DD statement.
Refer to the Compuware Shared Services User/Reference Guide for more information on the
LANGUAGE command, for a list of available compilers, and for more information on this
JCL and language processor options.
5-32
Enterprise Common Components Installation and Customization Guide
Postprocessor
You can use the postprocessor to process compile listings that were previously stored, or you can modify your Assembler compile JCL to pass the compiler listing to the postprocessor as described below.
• Check the assembler options.
• Change your assembler JCL to write the compiler listing (SYSPRINT) to a sequential file for use as input to the Assembler language postprocessor. A sample of the necessary JCL is shown below.
//SYSPRINT DD UNIT=SYSDA,SPACE=(TRK,(25,20)),DCB=BLKSIZE=16093,
// DISP=(MOD,PASS)
The above example is a temporary file. You can save the JCL as a permanent file to be reused as shown in the example below:
//SYSPRINT DD DSN=CX,STORED.LISTINGS(MEMBER)
• The SYSPRINT file will be LRECL=133, RECFM=FBA.
• Add SLCXCNTL sample library member CXASM as the postprocessor step following your assembler step. CXASM can be customized to meet your site’s requirements.
Note: The CWPLOAD file must be allocated using DISP=OLD or DISP=SHR.
• The object module that is processed by the postprocessor must be used as input to the linkedit step.
Refer to the Compuware Shared Services User/Reference Guide for more information on this JCL and language processor options.
Step 10d. Modify the JCL to Run the C Language Processor
You must perform this step if you are installing XPEDITER/TSO and you are licensed for the Compuware C language processor.
This step contains instructions for both the C language preprocessor and postprocessor.
You should follow the instructions that apply to the type of processing you will be performing.
Preprocessor
SLCXCNTL sample library member CXCPRE contains sample JCL necessary to run the C language preprocessor.
Modify the compile step of your C JCL:
• On the EXEC statement, change the name of your compiler to CWPZMAIN and add the following to any existing C compiler options:
LANGUAGE(compiler version)
Refer to the Compuware Shared Services User/Reference Guide for a list of the compiler versions that can be specified with the LANGUAGE command. The default compiler for C is the compiler currently in use on your system.
Note: The LANGUAGE command may be specified in the CWPPRMO command stream rather than on the EXEC statement.
CSS Customization
5-33
• Add the CSS SLCXLOAD DSN to the STEPLIB or JOBLIB concatenation if it is not in the link list.
• Add the CWPDDIO DD statement to specify the name of the source listing DDIO file you will be using. The source listing DDIO file may be in standard DDIO, shared directory, or database format. Releases prior to XPEDITER/TSO 7.3 do not support source listing shared directories. Instead, individual source databases may be specified for lower levels.
• Determine the language processor options you will use as input and add them to the
EXEC parameter, or add a CWPPRMO DD statement that points to the appropriate options. Sample options are contained in SLCXCNTL sample library member CXLPC to provide the smallest output to the source listing file (for minimizing space). If you use these options, and you will be using the C language preprocessor, add
LANGUAGE(xxx) to the EXEC PARM or to the CWPPRMO DD statement.
Refer to the Compuware Shared Services User/Reference Guide for more information on this JCL and C language processor options.
Postprocessor
You can use the postprocessor to process compile listings that were previously stored, or you can modify your C compile JCL to pass the compiler listing to the postprocessor as described below.
• Check the C compiler options.
• Change the C compile JCL to write the compiler listing (SYSCPRT) to a sequential file for use as input to the C language postprocessor. A sample of the necessary JCL is shown below.
//SYSCPRT DD UNIT=SYSDA,SPACE=(CYL,(100,10)),
// DCB=(RECFM=VB,BLKSIZE=16096),
// DISP=(MOD,PASS)
For more information on C language processor JCL, see the “C Language Processor” chapter in the Compuware Shared Services User/Reference Guide.
The above example is a temporary file. You can save the JCL as a permanent file to be reused as shown in the example below:
//SYSPRINT DD DSN=CX,STORED.LISTINGS(MEMBER)
• The SYSPRINT file will be LRECL=133, RECFM=FBA.
• Add SLCXCNTL sample library member CXC as the postprocessor step following your C compile step. CXC can be customized to meet your site’s requirements.
Note: The CWPLOAD file must be allocated using DISP=OLD or DISP=SHR.
• The object module that is processed by the postprocessor must be used as input to the linkedit step.
See the Compuware Shared Services User/Reference Guide for more information on this JCL and
C language processor options.
5-34
Enterprise Common Components Installation and Customization Guide
Step 11. Initialize the zIIP Enablement Service
(optional)
Overview
IBM has provided a mechanism for Independent Software Vendors (ISV), such as
Compuware, to execute portions of ISV product code on zIIP processors on the customer's system. Work executed on a zIIP processor is not charged for usage as with general use processors. As a result, when portions of Compuware product code are offloaded to execute on a zIIP processor, it can result in reduced costs for the customer.
The CSS zIIP Enablement Service provides a common method to enable selected portions of Compuware product code to be eligible to run on a zIIP processor. If available on your system, performance of Compuware software products can be enhanced by executing selected portions of the product on a zIIP processor. Execution on a zIIP processor can result in less billable CPU time used and significantly fewer I/O operations for normal product operation.
The CSS Cobol, PL/I, and Assembler language processors are particularly well-suited for zIIP processing. Executing the language processors with zIIP processing enabled can reduce CPU time used by 35 to 65% depending on the size and nature of the compiler listing being processed.
Enabling the Service
Before the service can be used, it must be started. Starting the service enables its API for use by other Compuware products. The service should be started once after system IPL; it remains active as long as the system remains running. The service can optionally be stopped, if desired.
In order to start the service, run the initialization utility program CXZPINIT, which just takes a moment. Once this is completed, Compuware products can begin using zIIP processing. The default JCL used to start the service is below.
//GO EXEC PGM=CXZPINIT
//STEPLIB DD DSN=COMPWARE.CX.SLCXAUTH,DISP=SHR
//SYSPRINT DD SYSOUT=*
//
It is recommended that the initialization utility be executed in an automated fashion after each system IPL. The utility can be executed as a job (just add an appropriate job card to the JCL above), or as a start command (if the JCL above is placed into a system
PROCLIB).
Upon successful initialization, the following message will appear in the job log:
CXZPINIT010I Initialization successful for ID CPWR
Other error messages are possible, and these are documented in the ECC Messages and
Codes.
Disabling the Service
This service can be temporarily disabled on a job-by-job basis, or completely disabled for the entire system.
CSS Customization
5-35
Job disablement
To disable the service for a specific job, use the CXZPIGNR DD statement:
//CXZPIGNR DD DUMMY
This statement will cause the job to execute without using the service. Note that the portions of the product that were designated for zIIP processing will still be executed normally, but not on a zIIP processor.
System-wide disablement
If you wish to disable the service for all jobs, use the initialization utility with an EXEC
PARM field to specify the keyword "DELETE", as shown in the example below:
//GO EXEC PGM=CXZPINIT,PARM=DELETE
//STEPLIB DD DSN=COMPWARE.CX.SLCXAUTH,DISP=SHR
//SYSPRINT DD SYSOUT=*
//
After running this JCL, the service will no longer be active in the system. The initialization utility can be re-executed to re-enable the service, if desired.
Step 12. Continue with ECC Customization
If you have any Compuware products that have been licensed for use by your organization and you have installed the LMS component, you must continue with the
procedures in Chapter 6, “LMS Customization”.
Note: If you have installed the Host Communications Interface (HCI) components, you should refer to the Host Communications Interface User/Reference Guide and appropriate product manuals for specific customization/configuration instructions.
5-36
Enterprise Common Components Installation and Customization Guide
6-1
Chapter 6.
LMS Customization
This chapter provides the basic procedures for setting up and customizing Compuware’s
License Management System (LMS) for use with the Compuware products licensed by your organization. It includes instructions for:
• Transferring a License Certificate to your host system.
• Setting up and using the License Administration Utility (LAU) to create a License File and define system nodes.
• Importing a Certificate into a License File.
• Initializing the LMS runtime environment.
This chapter provides only the most basic elements needed to establish a Compuware
LMS environment. To gain a more complete understanding of the LMS features consult the License Management System User/Reference Guide—MVS and the License Management System
User/Reference Guide—Centralized Licensing Facility. Both of these LMS manuals can be found on Frontline and on the product distribution media.
Preliminary Considerations
Which tasks you need to perform will depend on whether LMS has already been enabled at your site and whether you want to manage your Compuware license certificate from a central location or manage them individually on each of your LPARs.
The following is a list of items you might want to consider:
• Managing your licenses from a centralized location
• Running more that one license management system
• Managing more than one Compuware customer number
Managing your licenses from a centralized location
Please refer to the License Management System User/Reference Guide—Centralized Licensing
Facility for instructions on how to install a centralized licensing facility (CLF). The remainder of this document will discuss only the local maintenance of license certificates on each of your LPARs.
Running More than One License Management System
Under certain circumstances, a site may decide to run more than one instance of LMS on an MVS system. For instance, you might want both test and production LMS environments on the same MVS system. Compuware supports the environment of multiple LMS systems on a particular LPAR and information for establishing such an environment can be found in the User/Reference Guice (named previously), though for all but the most unusual implementations it is not necessary to run more than one LMS subsystem on any particular LPAR. One possible exception would be the installation of a complete new release of LMS where it is desired that existing Compuware products continue to execute normally during the time that the new release is installed and tested.
6-2
Enterprise Common Components Installation and Customization Guide
Managing More than One Compuware Customer Number
A site that manages multiple Compuware customer numbers, for example a service bureau, will have a License File for each Compuware customer number. The details for establishing a licensing environment consisting of multiple Compuware customer numbers can be found in the LMS User/Reference Guide.
Migration Considerations
The following items should be considered when upgrading from an earlier release of LMS to LMS release 4.0 or later:
• An LMS subsystem cannot be updated with an LMS 4.0 or later load library. You must delete the earlier version’s subsystem and then create the LMS subsystem. By specifying FUNCTION(DELETE) in the LMSINIT SYSIN parms the older subsystem will be deleted.
Note: Any products that were checked out or running when the earlier version’s subsystem was deleted should be shutdown and restarted.
• The LMS 2.0 checkpoint dataset cannot be updated with an LMS 4.0 or later load library. A new checkpoint that uses the LMS 4.0 or later file attributes must be created on each system running LMS 4.0 or later. LMS will automatically create the checkpoint data set using the name you supplied in the LMSINIT SYSIN parameters.
Choose a data set name that is different from the one you used with the older release.
• Ensure that the LMS EXIT_PROC passes the correct parameter format:
EXEC PGM=LMSENMGR,PARM=&LMSSYS
Be especially careful to insure that the //STEPLIB DD in the LMS EXIT PROC points to the new release 4.0 (or later) data sets. Often this step is overlooked and results with the LMS EXIT PROC for the older release unable to update the checkpoint data set created by LMS 4.0.
Which Steps Do I Need to Perform?
The choice of which steps to perform depends on whether LMS has already been installed and initialized as part a previous Compuware product installation. For this reason, the procedures in this chapter are tailored for two possible scenarios:
• You need to install and set up LMS for the first time, then enable it to work with the
Compuware product being installed.
• You are an established LMS user who only needs to enable it to work with the
Compuware product being installed.
As shown in Table 6-1, a first-time user must perform every step. Most established LMS
users can skip Steps 3, 4, and 5.
Table 6-1.
LMS Steps Required
First-Time User Step
x x
“Step 1. Transfer License Certificate to Host”
“Step 2. Set up License Administration Utility (LAU)”
x x
“Step 3. Create License File” on page 6-7
“Step 4. Verify License File” on page 6-9
x x x
“Step 5. Define Nodes” on page 6-10
“Step 6. Import License Certificate” on page 6-12
“Step 7. Prepare an APF Authorized LMSINIT” on page 6-14
Established User
x x a x x
LMS Customization
6-3
Table 6-1.
LMS Steps Required
First-Time User Step
x
“Step 8. Run LMSINIT” on page 6-15
x x
“Step 9. Verify Proper LMS Function” on page 6-16
“Step 10. Continue ECC Customization” on page 6-17
a.This step is required only if new license certificates have been received.
Established User
x x x
6-4
Enterprise Common Components Installation and Customization Guide
Installing and Enabling LMS
Follow the instructions below that apply to your situation.
Step 1. Transfer License Certificate to Host
LMS uses License Certificate files to configure access to Compuware products licensed by your organization. A License Certificate is a text file typically sent to your site via e-mail by Compuware’s Worldwide License Management team. To be used by LMS, a License
Certificate must be accessible to MVS.
1. Locate the License Certificate for the Compuware products being installed. A License
Certificate file can contain licensing for more than one Compuware product.
2. Allocate a target dataset on the host system for the License Certificate. Use the DCB parameters RECFM=FB, LRECL=80, and whatever BLKSIZE you prefer.
3. Transfer the License Certificate to the host using File Transfer Protocol (FTP),
IND$FILE, cut and paste, or any other method desired.
Note: If you open the License Certificate in an ISPF editor or transfer it using cut and paste, make sure NUMBERS is set to OFF.
4. If you have more than one License Certificate file, repeat the process as required.
LMS Customization
6-5
Step 2. Set up License Administration Utility (LAU)
This step creates the CLIST for starting the LAU, prepares the LAU to run, and makes it accessible to the License Administrators at your site.
1. Enter the following command to execute the LMSPREP EXEC from the SLMSCNTL library.
TSO EX '
your SMP/E dataset prefix
.SLMSCNTL(LMSPREP)'
Figure 6-1. Prepare License Administration Utility Screen
--------------------- Compuware License Management 04.00.00 -------------------
Prepare License Administration Utility
Type the data set prefix that will be used to execute the License
Administration Utility. The prefix shown below matches the
prefix that you selected for your License Management SMP/E data
sets. If you plan to execute the License Management System from
data sets other than the License Management SMP/E target or
distribution libraries, then enter the appropriate data set
prefix below.
Data Set Prefix. LM.PROD.R040000
The following messages will notify you that you have successfully tailored the
SLMSCNTL screen. Message LMP100I will be shown for each successfully tailored data set. Error messages will be displayed for any unsuccessful execution.
An example of the list of messages is shown below. You may have more messages in your particular environment-based upon features chosen:
LMP100I SLMSCNTL(CWLMA) SUCCESSFULLY TAILORED
LMP100I SLMSCNTL(CWLMQURY) SUCCESSFULLY TAILORED
LMP100I SLMSCNTL(CWLMDMSG) SUCCESSFULLY TAILORED
LMP100I SLMSCNTL(CWLMCHKP) SUCCESSFULLY TAILORED
LMP100I SLMSCNTL(LMUSER) SUCCESSFULLY TAILORED
LMP100I SLMSCNTL(ROIMAINT) SUCCESSFULLY TAILORED
LMP100I SLMSSENU(LMASTPLB) SUCCESSFULLY TAILORED
2. The second screen will be displayed only when the dataset prefix field displayed in the first screen was changed to a value that did not match the dataset prefix of the
SLMSCNTL library that contained LMSPREP. This is to accommodate customers who do not want to execute the LAU directly from the SMP/E target libraries for the
License Management System.
6-6
Enterprise Common Components Installation and Customization Guide
Figure 6-2. Prepare License Administration Utility - second screen
--------------------- Compuware License Management 04.00.00 -------------------
Prepare License Administration Utility
Please copy the contents of the SLMSCNTL and SLMSSENU SMP/E data sets
to the non-SMP/E controlled data sets that you wish to execute the
License Management System from.
3. Perform either of the following:
– Add the SLMSCNTL library to your SYSPROC concatenation, or
– Copy member CWLMA from the SLMSCNTL library into a dataset already concatenated to your SYSPROC DD.
4. Add the following line to an ISPF selection panel of your choice:
L,'CMD(%CWLMA) NOCHECK'
Note: Adding CWLMA to ISPF is optional, and you may execute CWLMA as a CLIST.
5. If your site has elected to secure the ISPF Command Table via an external security manager (i.e., RACF, TOPSECRET, or ACF2), then you must take appropriate steps to identify the command LMAMAIN to your external security manager.
6. If you are an established user, go to “Step 4. Verify License File” on page 6-9.
LMS Customization
6-7
Step 3. Create License File
If you have previously installed Compuware’s License Management System software, go
to “Step 4. Verify License File” on page 6-9.
In this step, you will use the LAU to create a License File.
screen (Figure 6-3) will be displayed.
Figure 6-3. License File Selection Screen
--------------------- Compuware License Management 04.00.00 -- Row 1 to 2 of 2
Command ===> SCROLL ===> PAGE
License File Selection
Current Selection:
Enter New DSN . .
(fully qualified without quotes)
Delete/Define . N (Y|N)
OR select below:-
Action DSN Added by
******************************* Bottom of data ********************************
2. Type the name you want to use for your License File (fully qualified without quotes) in the Enter New DSN field.
3. Type Y in the Delete/Define field.
4. Press Enter. The Delete/Define and Initialize License File screen (Figure 6-4) will be
displayed, and the file name you specified above will be shown in the New License
File field.
Figure 6-4. Delete/Define and Initialize License File Screen
--------------------- Compuware License Management 04.00.00 -- Row 1 to 2 of 2
Command ===> SCROLL ===> PAGE
Delete/Define and Initialize License File
New License File . : TSOID01.License.File.New
Unit . . . . . . . . _________ (required for JES3 only)
Volume Serial . . . _______ (blank for system determined volume)
Edit JCL . . . . . . Y (Y-Yes,N-No)
Press END Key to skip this process
Jobcard:
//Job Card information line 1
//Job Card information line 2
//Job Card information line 3
//Job Card information line 4
Select Node Description
******************************* Bottom of data ********************************
5. Type Y in the Edit JCL field.
6. Type the information for your jobcard in the four lines of the Jobcard field.
6-8
Enterprise Common Components Installation and Customization Guide
Note: If you are not using all four lines of the job card, comment out the unused lines.
7. Press Enter. The Edit Delete/Define JCL screen (Figure 6-5) will be displayed.
Figure 6-5. Edit Delete/Define JCL Screen
File Edit Confirm Menu Utilities Compilers Test Help
-------------------------------------------------------------------------------
EDIT SYS98274.T095731.RA000.TSOID01.R0111344 Columns0000100080
Command ===> Scroll ===>CSR
*************************************** Top of Data ***************************
000001 //Job Card information line 1
000002 //Job Card information line 2
000003 //Job Card information line 3
000004 //Job Card information line 4
000005 //*
000006 //*********************************************************************
000007 //* DELETE/DEFINE COMPUWARE LICENSE FILE
000008 //*
000009 //* JCL GENERATED BY TSOID01 ON 2001-05-17 AT 15:22
000010 //*********************************************************************
000011 //*
000012 //LFDELDEF EXEC PGM=IDCAMS
000013 //*
000014 //SYSPRINT DD SYSOUT=*
000015 //SYSIN DD *
000016 DELETE (TSOID01.License.File.New)
000017 SET MAXCC = 0
000018 DEF CL(NAME(TSOID01.License.File.New)
000019 IXD
8. Make any necessary edits, then enter the END command. A Confirm Submission window will be displayed over the Delete/Define and Initialize License File screen.
9. Type Y in the Confirm Submission window and press Enter. The JCL to create your
License File will be submitted.
10. Enter the END command. The License File Selection screen (Figure 6-3) will be
displayed.
11. After your job has completed with a good return code, type S in the Action field next to your new License File and press Enter. Your License File name will appear in the
Current Selection field.
12. Enter the END command.
– If you are a first-time user, the main Compuware License Management screen
(Figure 6-8 on page 6-10) will appear.
– If you are an established user, the Parameter Option screen (Figure 6-9 on page
6-10) will appear. To access the main Compuware License Management screen
(Figure 6-8 on page 6-10), enter the END command.
LMS Customization
6-9
Step 4. Verify License File
In this step, you will use the LAU to verify which License File you will be using.
before and a License File already exists, the main Compuware License Management
screen shown in Figure 6-8 on page 6-10 will be displayed. If the dataset name of the
License file that you want to use is displayed next to the Browse option, go to “Step
5. Define Nodes” on page 6-10.
2. Type 0 in the Option field and press Enter. The Parameter Option screen (Figure 6-6)
will be displayed.
Figure 6-6. Parameter Option Screen
--------------------- Compuware License Management 04.00.00 ------------------
Option ===>
1) Select License File - TSOID01.LICENSE.FILE
2) Node Specify System Nodes
X) Exit Return to previous panel
(C) Copyright 1998, Compuware Corp. All Rights Reserved.
3. Type 1 in the Option field and press Enter. The License File Selection screen (Figure 5-
7) will be displayed.
Figure 6-7. License File Selection Screen
--------------------- Compuware License Management 04.00.00 -- Row 1 to 2 of 2
Command ===> SCROLL ===> PAGE
License File Selection
Current Selection:
Enter New DSN . .
(fully qualified without quotes)
Delete/Define . N (Y|N)
OR select below:-
Action DSN Added by
_ LICENSE.FILE1 USERID1 2000-08-07
_ LICENSE.FILE2 USERID1 2000-08-07
******************************* Bottom of data ********************************
4. Type S in the Action field next to the file that you want to use and press Enter. Your selected file should appear in the current selection field.
6-10
Enterprise Common Components Installation and Customization Guide
Step 5. Define Nodes
If your installation does not consist of multiple nodes in a JES network, or if you do not require the ability to route License Management work (Import, Export, or Reporting)
In this step, you will use the LAU to define (to LMS) the network nodes on which License
Management maintenance or reporting tasks could be dispatched.
Figure 6-8. Main Compuware License Management Screen
--------------------- Compuware License Management 04.00.00 ------------------
Option ===>
0) Parameters Specify System Parameters
1) Browse License File - TSOID01.License.File
2) Update License File
3) IMPORT Import License Certificate
4) EXPORT Export License Certificate
5) Reports Run Reports
6) Disaster Enable Disaster Site
7) Emergency Emergency Password
X) Exit License Management
Copyright (c) 1999 Compuware Corporation. All Rights Reserved.
Unpublished rights reserved under the Copyright Laws of the United States.
Enter HELP for Copyright/Trade Secret Notice information.
1. Type 0 in the Option field and press Enter. The Parameter Option screen (Figure 6-9)
will be displayed.
Figure 6-9. Parameter Option Screen
--------------------- Compuware License Management 04.00.00 ------------------
Option ===>
1) Select License File - TSOID01.LICENSE.FILE
2) Node Specify System Nodes
X) Exit Return to previous panel
(C) Copyright 2010, Compuware Corp. All Rights Reserved.
2. Type 2 in the Option field and press Enter. The Maintain Nodes Table screen (Figure
LMS Customization
6-11
Figure 6-10. Maintain Nodes Table Screen
--------------------- Compuware License Management 04.00.00 -- Row 1 to 6 of 6
Command ===> SCROLL ===> PAGE
Maintain Nodes Table
Enter new node . . . ________
Description . . . . ____________________
OR
(C-Change,D-Delete)
Action Node Description Added by
_ Node1 Production TSOID01 2001-05-06 08:51
_ Node2 MVS Test1 TSOID01 2001-05-05 10:44
_ Node3 QA Test TSOID01 2001-05-22 10:38
******************************* Bottom of data ********************************
3. In the Enter new node field on the Maintain Nodes Table (Figure 6-10), specify the
name of the network node you want to add to the display list. This name identifies your installation’s local JES in a network of systems or system complexes being used for network job entry (NJE) tasks. The node name can be up to eight alphanumeric characters.
4. Describe the new node briefly in the Description field. This description can be up to
20 alphanumeric characters.
5. Press Enter. The screen will be redisplayed with the new node in the selection list at
the bottom of the screen. Repeat tasks step 3 through step 5 until you have defined
all of the required nodes.
6. Enter the END command. The Parameter Option screen (Figure 6-9) will be displayed.
7. Enter the END command again. The main Compuware License Management screen
(Figure 6-8) will be displayed.
6-12
Enterprise Common Components Installation and Customization Guide
Step 6. Import License Certificate
In this step the License Certificate for the Compuware product being installed will be imported into your site’s License File.
1. On the main Compuware License Management screen (Figure 6-8 on page 6-10), type
3 in the Option field and press Enter. The first of two Import License Certificate
screens (Figure 6-11) will be displayed.
Figure 6-11. First Import License Certificate Screen
---------------------- Compuware License Management 04.00.00 ------------
Command ===>
IMPORT License Certificate
Process DSN . : TSOID01.License.File
IMPORT From . . LICENSE.CERTIF__________________
(fully qualified without quotes)
Preview Only . . N (Y|N)
Reminder . . N (Y|N)
2. Type the name of the dataset used for your License Certificate file (fully qualified without quotes) in the IMPORT From field.
3. Type N in the Preview Only field.
Note: If you prefer to generate and review a report detailing the implications of the
License Certificate importation, enter Y in the Preview Only field. You then need to repeat this step with Preview Only set to N.
4. If you type Y in the Reminder field you will see the message LMA104I changes to the license file will not take effect until LMSINIT has been executed. If you type N, the reminder message will not appear.
5. Press Enter. The second Import License Certificate screen (Figure 6-12) will be
displayed.
Figure 6-12. Second Import License Certificate Screen
--------------------- Compuware License Management 04.00.00 -- Row 1 to 5 of 6
Command ===> SCROLL ===> PAGE
IMPORT License Certificate
Process DSN . : TSOID01.License.File
IMPORT From . . LICENSE.CERTIF
Preview Only . . N
Reminder . . N
Edit JCL . . . . Y (Y-Yes,N-No)
Jobcard:
//Job Card information line 1
//Job Card information line 2
//Job Card information line 3
//Job Card information line 4
Select Node Description
_ Node1 Production
_ Node2 MVS Test1
_ Node3 QA Test
****************************** Bottom of data ***********************
LMS Customization
6-13
6. Type Y in the Edit JCL field.
7. Type the information for your job card in the four lines of the Jobcard field.
Note: If you are not using all four lines of the job card, comment out the unused lines.
8. Type S next to the nodes on which you want the Import job to run. If no node is selected, the job is submitted without any specific routing.
Note: If you are running on only one node, do not make a selection here.
9. Press Enter. The Edit JCL screen (Figure 6-13) will be displayed.
Figure 6-13. Edit JCL Screen
File Edit Confirm Menu Utilities Compilers Test Help
-------------------------------------------------------------------------------
EDIT SYS98274.T095731.RA000.TSOID01.R0111344 Columns0000100080
Command ===> Scroll ===>CSR
************************************ Top of Data ******************************
000001 //Job Card information line 1
000002 //Job Card information line 2
000003 //Job Card information line 3
000004 //Job Card information line 4
000005//*
000006//*********************************************************************
000007//* IMPORT COMPUWARE LICENSE CERTIFICATE
000008//*
000009//* JCL GENERATED BY TSOID01 ON 2001-07-08 AT 15:32:17
000010//*********************************************************************
000011//*
000012//IMPORT EXEC PGM=LMALFIM,
000013// PARM=’UPDATE’
000014//STEPLIB DD DSN=LM.DEVL.LOAD,
000015// DISP=SHR
000016//*
000017//CWLF0000 DD DSN=TSOID01.License.File,
000018// DISP=SHR
000019//CWLFIMP DD DSN=LICENSE.CERTIF,
10. Make any necessary edits, then enter the END command. A Confirm Submission window will be displayed over the second Import License Certificate screen.
11. Type Y in the Confirm Submission window and press Enter. The JCL to create your
License File will be submitted.
12. Enter the END command. The main Compuware License Management screen (Figure
6-8 on page 6-10) will be displayed.
13. Type X in the Option field and press Enter to exit the LAU.
14. Proceed as follows:
– If you are a first-time user, continue with “Step 7. Prepare an APF Authorized
– If you are an established user, go to “Step 8. Run LMSINIT” on page 6-15.
6-14
Enterprise Common Components Installation and Customization Guide
Step 7. Prepare an APF Authorized LMSINIT
If you are an established user, please ensure that the modules listed below are copied from your License Management SMP/E target load library into your License Management
APF authorized load library and go to “Step 8. Run LMSINIT” on page 6-15.
In this step, you will ensure that the LMS modules will be loaded from an APF authorized library, and you will also create the customized proc, JCL, and parameters dataset that will be used by LMSINIT to build the LMS runtime environment.
1. In order to function correctly, the LMS load modules must reside in an MVS APF authorized library. Consult your site’s MVS system programmer for details. This can be accomplished in either of the following ways:
– APF authorize the library in which all the load modules for LMSINIT currently reside.
Because modules can be added over time via PTF, the most current list of modules that must reside in an APF-authorized data set can be found in the SAMPLE data set member name #APFMODS. Please refer to this member for a current list of modules.
Note that modules suffixed with two asterisks must be bound with AC=1. All other modules must be bound with AC=0 or allowed to default to this value.
Parameters used by LMSINIT are read from a SYSIN dataset. Edit the sample dataset
provided in SLMSCNTL(LMINPARM) (see Figure 6-13).
– The operand and its associated value can start in any column and can be continued on more than one statement.
– Columns 1 through 71 are available for use.
– Column 72 is reserved.
– Columns 73 through 80 can be used for sequence numbers. They are ignored by
LMSINIT.
– To continue an operand on a second statement, complete the first statement through column 71, and continue the operand on the next statement starting in column 1.
– Only the value specified for SUBSYSTEM_ID is case-sensitive. All other operands and their values are folded to upper case by LMSINIT.
– Only one occurrence of each of the operands is allowed. If duplicates exist, the last one encountered will be used.
– An asterisk ‘*’ in column 1 causes the entire statement to be a comment.
– Line level comments are supported using the ‘/*’ to start a comment and ‘*/’ to end the comment. Imbedded comments are supported.
For more information about specific parameters, refer to the chapter entitled
“Creating Runtime Environment” in the License Management System User/Reference Guide.
Note: The following parameters are required: FUNCTION(UPDATE), SITE(),
SUBSYSTEM_ID(), CHKPT_DSNAME(), EXIT PROC().
Sample LMSINIT Parameters Dataset
You will find a sample LMSINIT parameter data set in the sample data set shipped to you and installed with LMS. The member name is LMINPARM and should be used as a skeleton for parameters for you particular installation. Since this member can change with PTF maintenance, it is not listed here.
LMS Customization
6-15
2. To ensure access to Compuware products is automatically enabled, establish a procedure in your SYS1.PROCLIB to launch LMSINIT as a started task during IPL and
IML processing. Consult your site’s MVS system programmer for details. Edit the
sample proc provided in SLMSCNTL(LMINPROC) (Figure 6-14). Change the data set
names to match those used at your site.
Note: This proc must run before any other Compuware product procs.
Figure 6-14. Sample LMSINIT Proc
//LMSINIT PROC
//LMSSTEP EXEC PGM=LMSINIT,PARM=’LANGUAGE=EN’
//STEPLIB DD DISP=SHR,DSN=USER.LMS.AUTHLOAD <==== CHANGE DSN
//SYSPRINT DD SYSOUT=*
//CWLF0000 DD DISP=SHR,DSN=YOUR.VSAM.LICENSE.FILE <==== CHANGE DSN
//SYSIN DD DISP=SHR,
// DSN=<SMPE.HLQ>.SLMSCNTL(LMINPARM) <==== CHANGE DSN
3. Edit the sample JCL provided in SLMSCNTL(LMINJCL) (Figure 6-15). Change the
dataset names to match those used at your site.
Figure 6-15. Sample LMSINIT JCL
//*
//* YOUR JOBCARD GOES HERE
//*
//LMSSTEP EXEC PGM=LMSINIT,PARM=’LANGUAGE=EN’
//STEPLIB DD DISP=SHR,DSN=USER.LMS.AUTHLOAD <==== CHANGE DSN
//SYSPRINT DD SYSOUT=*
//CWLF0000 DD DISP=SHR,DSN=YOUR.VSAM.LICENSE.FILE <==== CHANGE DSN
//SYSIN DD DISP=SHR,
// DSN=<SMPE.HLQ>.SLMSCNTL(LMINPARM) <==== CHANGE DSN
Step 8. Run LMSINIT
Submit your site’s customized LMSINIT JCL created from the sample provided in
SLMSCNTL(LMINJCL) (Figure 6-15). This will establish the runtime environment that
enables LMS to function.
6-16
Enterprise Common Components Installation and Customization Guide
Step 9. Verify Proper LMS Function
In this step, you will use the LAU to generate a License Verification Report. You can then use that report to verify that the procedures in this chapter were performed correctly and
LMS is operating properly.
Management screen shown in Figure 6-8 on page 6-10 will be displayed.
2. Type 5 in the Option field and press Enter. The Reports screen (Figure 6-16) will be
displayed.
Figure 6-16. Reports Screen
--------------------- Compuware License Management 04.00.00 -- Row 1 to 3 of 7
Command ===> SCROLL ===> PAGE
Report Selection
Select "D" for Detail, or "S" for Summary
Expire Date Process DSN
_ License Verification
_ Current Cache Report
_ VSAM License File
_ SAM License File
_ SMF License Records
_ Product Activity
_ Activity Extract
Edit JCL . . . . N
Jobcard:
//Job Card information line 1
//Job Card information line 2
//Job Card information line 3
//Job Card information line 4
Select Node Description
_ Node1 Production
_ Node2 MVS Test1
_ Node3 QA Test
3. Type S next to License Verification.
4. Type Y in the Edit JCL field.
5. Type the information for your jobcard in the four lines of the Jobcard field.
Note: If you are not using all four lines of the job card, comment out the unused lines.
6. Type S next to the nodes on which you want the Report job to run. If no node is selected, the job is submitted without any specific routing.
Note: If you are running on only one node, do not make a selection here.
7. Press Enter. An Edit JCL screen will be displayed.
8. Make any necessary edits, then enter the END command. A Confirm Submission window will be displayed over the Reports screen.
9. Type Y in the Confirm Submission window and press Enter. The JCL to create your
License Verification Report will be submitted.
10. Enter the END command. The main Compuware License Management screen (Figure
6-8 on page 6-10) will be displayed.
11. Type X in the Option field and press Enter to exit the LAU.
LMS Customization
6-17
12. Use SDSF to examine the License Verification Report and ensure that the Compuware product being installed is recognized and enabled by LMS.
Step 10. Continue ECC Customization
The ECC installation and customization procedures are now complete. Please return to your product’s installation guide and proceed with the installation instructions provided there.
Notes:
1. If you have installed the Host Communications Interface (HCI) components, you should refer to the appropriate product manual for specific customization/configuration instructions.
2. If you are installing Abend-AID or Abend-AID for CICS, refer to the respective installation and customization guides for configuration instructions concerning the
HCI libraries.
Resolving Problems
If any error messages were returned while performing steps in this chapter, refer to the
Enterprise Common Components Messages and Codes guide.
If you encountered any other difficulties related to License Management System, please consult the License Management System User/Reference Guide for more information. If problems persist, contact Compuware Technical Support.
6-18
Enterprise Common Components Installation and Customization Guide
A-1
Appendix A.
SMP/E Installation Using GUI Interface
Appendix A.
Note: Compuware recommends using the Receive From Network (RFN) installation procedures to SMP/E install the product files. Follow the instructions in this
appendix only if you cannot perform an RFN installation. See Chapter 3,
“Receive From Network (RFN) Installation” for more information.
IMPORTANT:
If the current release of the ECC components exists on your system, select the
Maintenance Only checkbox in the file upload dialog executed on your PC. This will upload the maintenance, HOLDDATA, and abstract files to your mainframe.
See Chapter 4, “Applying Maintenance”.
CAUTION:
To prevent possible conflicts, Compuware strongly recommends that all
Compuware products and components distributed via SMP/E share a single
Global zone reserved solely for Compuware products. Target and distribution zones should not be shared with other products or different releases of the same product.
This chapter explains the steps required to install the primary portions of Compuware’s
Enterprise Common Components (ECC), including:
• Compuware Shared Services (CSS)
• License Management System (LMS)
• Host Communications Interface (HCI)
The procedures in this chapter unload the ECC media and install the components into datasets. Although the full ECC installation procedure is discussed in this chapter, you may only need to perform certain portions depending on which products are used at your site. You should already have determined in the previous chapter which components you need to install.
Except where otherwise noted, the return code from all jobs should be zero.
The ECC installation process utilizes System Modification Program Extended (SMP/E).
For more information about this type of installation, and other installation
considerations, please refer to Chapter 2, “Preparing for ECC Installation”. For more
information about SMP/E, consult the IBM SMP/E Reference or the IBM SMP/E User’s Guide.
Notes:
1. If you have previously installed components from an ECC release, some of the values displayed on the install panels may be populated from values stored in the installing user’s TSO profile. Please verify each panel carefully before continuing.
2. Approved PTFs are normally added to the Enterprise Common Components CD on a monthly basis. If you receive more than one CD dated within a given month, the
maintenance on these CDs may be identical. See Chapter 4, “Applying Maintenance”
for complete maintenance installation instructions.
A-2
Enterprise Common Components Installation and Customization Guide
Upload Product Files and Perform SMP/E Installation
Compuware provides a convenient way to upload product files and perform an SMP/E installation, all from a straightforward PC workstation interface. When you insert the product media for mainframe Extended Play (EP) products (or double-click the Setup.exe file from an electronic distribution), the product Setup dialog box appears. You can use this interface to upload product installation and/or maintenance files to the mainframe and perform a full SMP/E installation.
Notes:
• Some product media do not support SMP/E installation. Such media can be easily identified by the absence of the SMP/E Install tab on the Setup dialog box’s
Mainframe Products tab. If your product media does not contain the SMP/E Install tab, skip these instructions and go to the appropriate appendix in the product’s
Installation Guide that contains upload and installation instructions for non-SMP/E media.
• If you prefer using a mainframe TSO session to complete the SMP/E installation or application of maintenance, go to the appropriate appendix in the Installation Guide for the product you are installing and continue with the instructions there.
• You may optionally upload the files only, including all SMP/E installation JCL, and then use a mainframe session to perform the SMP/E installation.
The interface also includes a tab for contacting Compuware Customer Support and may include tabs for Windows
®
products and third-party products. For more information, see
“Install Windows and Third-Party Products” on page A-11.
System Requirements and Preparation
Before using the upload/installation interface, make sure your system meets the following requirements:
• Internet Explorer 6.0 or above
• Adobe Reader 6.0 or above to view PDF documents
• If your PC’s display DPI setting makes the interface difficult to view, temporarily set it to Normal size (96 DPI).
Firewall Settings
Either configure software firewalls running on your PC to grant the upload application
(cwftpw.exe located in folder \cpwr of the media) network access to your mainframe, or disable firewalls during the upload.
Information on the Media Label
If you are installing from physical media, the media label provides information about installation or operating capability, as noted below:
Name/Release
Name and release of the product.
Creation
The product’s installation media label shows when it was made. Compare this creation date with any maintenance posted on the Compuware Go customer support
Website at http://go.compuware.com.
If additional maintenance has become available since the date on the installation media, either download the maintenance, or call Customer Support to request new installation media with the current maintenance.
SMP/E Installation Using GUI Interface
A-3
Select Items for Upload
IMPORTANT: Sample Xpediter Setup dialog boxes are shown in this section, but the steps are applicable to other Compuware mainframe products.
In addition to installation, maintenance, and documentation files, the product media (or electronic distribution) contains an HTML-based upload/installation application used to
FTP-transfer the necessary files to your mainframe.
1. Insert the media into the drive or double-click Setup.exe. A product Setup dialog box similar to that shown in Figure A-1 appears. The Mainframe Upload tab of the
Mainframe Products tab is shown first. Fields marked with an asterisk (*) are required.
Figure A-1. Mainframe Upload Dialog, Upper Portion
Note: Do not click the Upload Product Files button until all required fields have been filled in.
2. Following your site’s standards, enter a value in the High Level Qualifier for
Common Files field. Common files are datasets that can be used across multiple products on the EP and may include maintenance files, MCS files, and sample libraries. The default high level qualifier is SYS1.CPWR.COMMON. If you do not have ALTER access to this hlq, you must change it to a qualifier you can create files under.
3. Select the files to be uploaded as follows:
– If you want to upload files for all of the products listed, use the All row as follows:
1. Click either the Product and Maintenance check box or the Maintenance
only check box.
2. Enter an appropriate qualifier in the Unload High Level Qualifier field. Be sure you are allowed to create files under this qualifier.
A-4
Enterprise Common Components Installation and Customization Guide
Note: The ISPF SMP/E JCL generation dialogs are currently designed to handle only a Common Unload High Level Qualifier. If you plan to use the mainframe ISPF dialog to generate SMP/E JCL for more than one product, you must use the same upload hlq for all of them. This restriction does not apply if you are planning to use the Setup dialog box’s SMP/E Install tab to generate installation JCL.
– If you want to upload a selected combination of product and/or maintenance files, use the individual product rows as follows:
Note: Some products may require a component that is common to multiple products. For example, if you select Abend-AID and/or Abend-AID for
CICS, you should also select Abend-AID Base Services.
1. Click either the Product and Maintenance check box or the Maintenance
only check box for each product you want to install or apply maintenance to.
2. Optionally, click the Japanese Support check box if you plan on installing localized or Japanese language support.
3. Optionally, enter an appropriate qualifier in the product Unload High Level
Qualifier field. If the product is not selected for upload, this field will be ignored. If this field is cleared, it will be reset to the default value.
4. Scroll down to view the lower portion of the dialog box as shown in Figure A-2.
5. Edit the sample information in the Job Card field as required.
Note: The job class specified must allow enough CPU time for long-running jobs.
Running the SMP/E APPLY and ACCEPT steps will result in the generation of a large amount of output. Be sure to set your job card Class and Lines parameters accordingly.
Figure A-2. Mainframe Upload Dialog, Lower Portion
SMP/E Installation Using GUI Interface
A-5
Enter File Transfer Settings
1. In the Mainframe FTP Information area, specify the values to be used during FTP transfer of the product installation and maintenance files as follows:
– In the Host field, enter your host mainframe’s IP or DNS name.
– In the User Id field, enter the TSO user ID to use for the FTP session.
– In the Password field, enter the password associated with the TSO user ID above.
– In the Port field, enter the number of the host port used for FTP uploads and downloads. The default is 21.
– In the Dasd Unit field, enter the esoteric unit to delete temporary upload files.
The default is SYSDA.
2. (Optional) Specify the storage options to be used on the mainframe as follows:
– In the Volume field, enter the name of the volume on which to place the uploaded files. Be sure the target volume has enough space to hold all the files uploaded.
Note: Click the File Size button to display an estimate of the minimum number of tracks required to upload the selected products. The estimate assumes
3390 DASD and will be less accurate for different DASD. Compuware recommends adding 5% to the estimated minimum tracks value.
– If using SMS, enter the appropriate class to apply to the uploaded files in the SMS
Storage Class field.
Upload Files
When the desired installation and/or maintenance files have been selected and all required fields have been filled in, click Upload Product Files to upload the selected files in TSO XMIT format, along with the JCL to perform a TSO RECEIVE of the files.
The upload/installation application uploads the required files to your mainframe. The name of the file containing the JCL to TSO RECEIVE the files is shown at the bottom of the screen.
Note: The Compuware EP Setup upload confirmation dialog may include one or more messages indicating the upload status of Common file set n. The upload of
Common file set 0 normally includes UNLOAD, UPLDEL, and SMPE.DATA files.
Other files may also be uploaded, depending on the design of the EP.
Enter SMP/E Settings
Notes:
• If you prefer using a mainframe TSO session to complete the SMP/E installation or application of maintenance, go to the appropriate appendix in the Installation Guide and continue with the instructions there.
• At the end of the SMP/E install process below, if you click Upload SMP/E JCL to the
Mainframe and SUBMIT, the TSO RECEIVE discussed above is executed automatically as part of the SMP/E install.
The products’ Setup dialog box enables SMP/E installation of the selected product and/or maintenance files directly from your PC.
1. Click the SMP/E Install tab. The dialog shown in Figure A-3 appears, listing the product installation and/or maintenance files you uploaded previously.
A-6
Enterprise Common Components Installation and Customization Guide
Figure A-3. SMP/E Install Dialog, Upper Portion
Note: Do not click either of the Upload SMP/E JCL to the Mainframe buttons until all required fields, including those under SMP/E Options, have been filled in. Be sure to use names or hlq that you have UPDATE or ALTER access for as necessary.
2. Specify the basic values to be used during the SMP/E process as follows:
– In the Compuware GLOBAL CSI Dataset field, enter the name of the CSI dataset used for Compuware products. The default is SYS1.CPWR.GLOBAL.CSI.
– Click the appropriate button under Does the Global CSI already exist? depending on whether the CSI exists and, if so, whether it has been set up for
Compuware use.
– In the HLQ for Compuware SMP/E Datasets field, enter the high-level qualifier to be used for the SMP/E datasets on the mainframe. The default is
SYS1.CPWR.GLOBAL.
– In the Compuware Products High-level qualifier field, enter the high-level qualifier associated with the products to be installed. The default is SYS1.CPWR.
Note: The value entered in this field becomes the default for the High Level
Qualifier fields on the Zone Info part of the screen in the next step. Any
HLQ you enter there will override the default value for installing that specific product.
– In the DASD Unit field, enter the appropriate symbolic unit. The default is
SYSDA.
– (Optional) In the DASD Volser field, enter the appropriate storage volume serial information. Be sure the target volume has enough space to hold all your files.
– In the SMP/E Work Unit field, enter the name of the appropriate SMP/E work symbolic unit. The default is SYSDA.
SMP/E Installation Using GUI Interface
A-7
3. Click the plus (+) sign next to SMP/E Options to expand that area of the screen as shown in Figure A-4.
Figure A-4. SMP/E Install Dialog, SMP/E Options Area
4. Click the plus sign next to Zone Info. The SMP/E target and distribution zone fields shown in the upper part of Figure A-5 appear. For each item listed, edit the values in the Target Zone Name, Distribution Zone Name, and each of the High Level
Qualifier fields, as necessary. The High Level Qualifier fields default to the value in the Compuware Products High-level qualifier field, but you can enter override values on a product-by-product basis.
A-8
Enterprise Common Components Installation and Customization Guide
Figure A-5. SMP/E Install Dialog, Zone Info and System Utilities Portion
5. Click the plus sign next to System Utilities. The utilities fields shown in the lower part of Figure A-5 appear. Standard defaults are pre-filled. For each item listed, enter the applicable value as required.
6. Click the plus sign next to SMS parameters. The parameters fields shown in the upper part of Figure A-6 appear. Enter the data class, storage class, or management class SMS parameters for SMP/E datasets if they are required at your site.
SMP/E Installation Using GUI Interface
A-9
Figure A-6. SMP/E Install Dialog, SMS Parameters and Dataset Definitions Portion
7. Click the plus sign next to Cross-Product and/or Non-Compuware Dataset
Definitions. Dataset Name fields similar to those shown in the middle part of Figure
A-6 appear. Enter the appropriate DSN for each dataset listed. If you are installing individual products or maintenance only, you may not need to enter values for all
DSNs.
Note: DevEnterprise requires a DSN for the Host Communications loadlib (SLHCLOAD), and if that field is left blank, a message may appear. If you are installing
DevEnterprise, click Cancel, enter a DSN for SLHCLOAD, and retry the upload.
Otherwise click OK to dismiss the message and continue with the installation.
8. If necessary, edit the sample information in the Job Card field as required.
9. Make any necessary revisions to the Mainframe FTP Information fields.
Upload and Submit Installation Jobs
When the desired items on the SMP/E Install tab have been selected and all required fields have been filled in, do one of the following:
• Recommended: To upload the JCL and submit it immediately to initiate the SMP/E process, click Upload SMP/E JCL to the Mainframe and SUBMIT.
• Optional: To upload the JCL to be submitted manually later, click Upload SMP/E
JCL to the Mainframe. You will need to use a mainframe TSO session to complete the SMP/E installation or application of maintenance. Go to the Installation Guide appendix entitled “Installing Enterprise Common Components Using ISPF” and continue with the instructions there.
The upload/installation application uploads the required files to your mainframe and, if
SUBMIT was clicked, initiates the SMP/E installation procedure.
A-10
Enterprise Common Components Installation and Customization Guide
Continue the installation and product configuration process below. For the most current installation instructions and Release Notes, visit the Compuware Go customer support
Website at go.compuware.com.
SMP/E JCL Uploaded to the Mainframe
When SMP/E installation generation is done from the PC using the upload/installation application rather than using the ISPF Installation JCL Customization Facility, dataset
<hlq>.<prodid>.SMPE.JCL
is uploaded to the mainframe. This dataset contains the JCL used to perform an SMP/E installation, along with jobs that process maintenance files
(uploaded from media or downloaded from Compuware Go).
*$01GLCSI 1. Allocate the SMPLOG and SMPPTS datasets.
2. Define a VSAM cluster for use as a separate global CSI for installing
Compuware products, then load the SMP/E initialization record
(GIMZPOOL) into it.
3. Initialize the global CSI with appropriate Zonedef, option, and DDDEF entries.
* Depending on the selection made in the upload/installation application, this member may not exist, or items 1 and 2 may be bypassed.
$02TZCSI
$03ALDSN
$04RECV
$05APPLY
$06ACCPT
$07SUBMT
$10MNTJB
$14MRECV
$15MAPLY
$16MACPT
2. Delete and define the target and distribution zone clusters and support files.
3. Update the global CSI with component specific Zonedef, option, and
DDDEF entries.
4. Initialize the product target and distribution zone CSIs with DLIBZONE,
TARGETZONE, option, and DDDEF entries.
1. Delete any existing SMP/E libraries and datasets.
2. Allocate the SMP/E libraries and datasets.
Receive the base code and maintenance PTFs
Apply base code and maintenance PTFs into target SMP/E libraries.
Accept base code into the SMP/E distribution libraries.
Note: Use job $16MACPT to accept maintenance PTFs.
This jobstream is the JCL that is submitted when Upload SMP/E JCL to the
Mainframe and Submit is clicked. It is a concatenation of the above members (minus extra jobcards) into a single member.
This jobstream is the JCL that is submitted when Upload SMP/E JCL to the
Mainframe and Submit is clicked and Maintenance Only is selected. It is a concatenation of members $14MRECV and $15MAPLY (minus extra jobcards) into a single member.
This jobstream receives the maintenance file(s) for installed components.
Update JCL statements SMPPTFIN and SMPHOLD to point to the files uploaded from the media, electronic distribution, or Compuware Go (or downloaded from FTP).
This jobstream will apply the maintenance PTFs to the SMP/E files
This jobstream will accept the maintenance PTFs to the SMP/E files
SMP/E Installation Using GUI Interface
A-11
Upload/Installation FAQs
What should I do if I receive a message stating that I am not an Administrator and cannot perform product installation?
For Windows releases prior to Windows 7, this message can be ignored. You do not need
Administrator rights because nothing is being installed on your PC from the media. The upload/installation application simply facilitates the upload of files to the mainframe and, optionally, their installation there.
Windows 7 users with User Account Control (UAC) settings higher than Never notify must have administrator privileges on their PC—or have access to an ID and password with administrator privileges—to run the upload/installation application.
What should I do if I receive a message stating “Install Program As Other User”?
Select Run the program as your-domain\your-domain-id and click OK to continue.
Nothing is installed on your PC. The upload/installation application simply facilitates the upload of files to the mainframe and, optionally, their installation there.
What should I do if I receive a message stating “Error: You must have a supporting browser”?
Install Internet Explorer 6.0 or above and set it as your default browser. Contact your
System Administrator for more information.
What should I do if I receive a message stating “Cannot connect to host xxxxx:nn”?
The host name or remote port you specified on the Mainframe Upload dialog is incorrect.
Contact your System Administrator for the host ID of the mainframe. The host name is the domain name or IP address of the mainframe. It may be the LPAR system ID or it may be some other name.
What should I do if the upload is slow, doesn’t complete, or I receive a number of transfer-retry messages?
Windows firewall and third-party firewalls can cause numerous retries and time-outs. All firewalls should either be configured to allow the upload application access to the mainframe or they should be disabled during the upload process.
What should I do if I am using Windows 7, and a Program Compatibility Assistant dialog box appears after I close the product Setup dialog box?
You can simply click Cancel to dismiss the dialog box. To prevent it from reappearing the next time you close the product Setup interface, click This program installed correctly instead. Note that the dialog box may reappear when using subsequent product distributions.
What should I do if I can’t view some or all of the documentation?
Adobe Reader 6.0 or above is required to view and use the PDF/PDX files. You may be able to view the PDF files with an older version. However, you will not be able to use a PDF index file (.pdx), which significantly speeds searches and allows you to search the entire set of documents at once. Download a free copy of the reader from www.adobe.com.
Install Windows and Third-Party Products
The same Extended Play (EP) Setup dialog box that allows you to upload and install mainframe products (see “Upload Product Files and Perform SMP/E Installation” on page
A-2) also includes a Contact Us tab for contacting Compuware Customer Support and
may include tabs for Windows
®
products and third-party products.
A-12
Enterprise Common Components Installation and Customization Guide
Installing Windows Products
When you insert the product media for mainframe EP products (or double-click the
Setup.exe file from an electronic distribution), the products’ Setup dialog box appears.
Click the Windows
®
Products tab. A dialog box similar to the one shown in Figure A-7 appears. Use the links and follow the on-screen prompts to install the desired software.
Figure A-7. Windows
®
Products Tab
Installing Third-Party Products
Click the 3rd Party Products tab. A dialog box similar to the one shown in Figure A-8 appears. Use the links and follow the on-screen prompts to install the desired software.
Figure A-8. 3rd Party Products Tab
B-1
Appendix B.
Installing CSS, LMS, and HCI Using ISPF
Appendix A.
Notes:
1. Compuware recommends using the Receive From Network (RFN) installation
procedures to SMP/E install the products. See Chapter 3, “Receive From Network
(RFN) Installation” for the instructions.
2. If your site cannot use the Receive From Network (RFN) installation procedures,
Compuware recommends using the EP upload and installation procedure described
in Appendix A, “SMP/E Installation Using GUI Interface”.
3. Appendix B is intended for only those sites that either must use ISPF to SMP/E install the product files, or used the EP interface only to upload product files to the mainframe and plan to use ISPF to complete the SMP/E installation.
IMPORTANT:
If the current release of the ECC components exist on your system, select the
Maintenance Only checkbox in the file upload dialog executed on your PC. This will upload the maintenance, HOLDDATA, and abstract files to your mainframe.
See Chapter 4, “Applying Maintenance”.
CAUTION:
To prevent possible conflicts, Compuware strongly recommends that all
Compuware products and components distributed via SMP/E share a single
Global zone reserved solely for Compuware products. Target and distribution zones should not be shared with other products or different releases of the same product.
This chapter explains the steps required to install the primary portions of Compuware’s
Enterprise Common Components (ECC), including:
• Compuware Shared Services (CSS)
• License Management System (LMS)
• Host Communications Interface (HCI)
The procedures in this chapter unload the ECC media and install the components into datasets. Although the full ECC installation procedure is discussed in this chapter, you may only need to perform certain portions depending on which products are used at your site. You should already have determined in the previous chapter which components you need to install.
Except where otherwise noted, the return code from all jobs should be zero.
The ECC installation process utilizes System Modification Program Extended (SMP/E).
For more information about this type of installation, and other installation
considerations, please refer to Chapter 2, “Preparing for ECC Installation”. For more
information about SMP/E, consult the IBM SMP/E Reference or the IBM SMP/E User’s Guide.
Notes:
1. If you have previously installed components from an ECC release, some of the values displayed on the install panels may be populated from values stored in the installing user’s TSO profile. Please verify each panel carefully before continuing.
B-2
Enterprise Common Components Installation and Customization Guide
2. Approved PTFs are normally added to the Enterprise Common Components CD on a monthly basis. If you receive more than one CD dated within a given month, the
maintenance on these CDs may be identical. See Chapter 4, “Applying
Maintenance” for complete maintenance installation instructions.
Step 1. Unload the ECC Installation Files
The ECC installation sample library contains JCL used to complete the ECC installation process. This library is contained on the second file of the ECC tape, or is downloaded to the mainframe from CD or the CD image from the FTP site. Files downloaded from the
CD or FTP are in TSO XMIT compressed format. After unloading the files from tape or running the jobstream to do the TSO RECEIVE, you can review member $$INDEX of the installation sample library for a description of each of the supplied members.
If you are installing from CD or FTP, JCL to do a RECEIVE is included in dataset hlq.CYnnnnnn.UNLOAD. Update the jobstream per the instructions in the file and
submit to RECEIVE the Installation files, then proceed with “Step 2. Select Installation
If you are installing from a tape, you should have received a document containing sample JCL to unload the files from tape to disk. Cut/paste the sample JCL to a file or
PDS member and update per the instructions in the file.
Step 2. Select Installation Components
The ECC Installation JCL Customization Facility uses ISPF panels to gather your installation information. It then uses that information to build the jobs needed to perform the SMP/E installation.
Note: The Installation JCL Customization Facility requires a minimum of ISPF/PDF version 3.5. REXX is also required.
For information on resolving error messages from the installation facility, refer to the
Enterprise Common Components Messages and Codes guide.
Begin the process of installing LMS, CSS, and/or HCI using the Installation JCL
Customization Facility as follows:
1. Invoke the installation facility by entering the TSO EXECUTE command with the dataset name of the installation library followed by ECCINST. For example:
TSO EX 'hlq.CPWR.CYnnnnnn.INS($$ECINST)' where hlq.CPWR.CYnnnnnn.INS is the name of your installation sample library.
The entry panel for the Installation JCL Customization Facility (Figure B-1) will be
displayed.
Installing CSS, LMS, and HCI Using ISPF
B-3
Figure B-1. Selecting
Components
to Install
Compuware Enterprise Common Components Release 3.2.0
SMP/E Installation JCL Customization Facility
Command ==>
Place an "S" by one or more of the following components to select that
component for customization. To deselect a component, delete the "S"
_ Compuware Shared Services 9.0
_ License Management System 4.0
_ Host Communications Intf. 3.0
Press PF1 for help, END to exit.
2. Enter an S to the left of each component you want to install. Remember the following:
– If you are installing from files uploaded from CD, you will only be able to install the components you selected in the upload dialog.
– If you have previously installed any of the above component releases, you should not select them. Use the install CD as a maintenance CD instead for that
component. See Chapter 4, “Applying Maintenance”. Ignore comments below
that state you MUST install that particular component: it does not need to be reinstalled.
– If you only require CSS, select only CSS on this panel.
– If you only require LMS, select only LMS on this panel.
– If you use Abend-AID 9.0 or more current and plan to use Distributed Viewing
Support, you must install the CSS and HCI components.
Note: If you are installing more than one component, Compuware recommends installing them simultaneously.
To indicate your choices, the word SELECTED will be displayed next to each
component chosen. Figure B-2 shows the confirmation text that would be displayed
if component CSS was selected for installation.
B-4
Enterprise Common Components Installation and Customization Guide
Figure B-2. Confirming Installation Selections
Compuware Enterprise Common Components Release 3.02.00
SMP/E Installation JCL Customization Facility
Command ==>
Place an "S" by one or more of the following components to select that
component for customization. To deselect a component, delete the "S"
S Compuware Shared Services 9.0 SELECTED
_ License Management System 4.0
_ Host Communications Intf. 3.0
Press Enter to begin JCL Customization for the selected component(s).
Select all desired components before continuing.
Press PF1 for help, END to exit.
3. To modify a selection, add or delete the S to the left of the component.
4. When you are satisfied with your selections, press Enter again to start the JCL customization process.
Step 3. Specify ECC Installation Environment
Information
Note: Changing a value on this screen from its value in a prior execution of this dialog could result in the message 'Default values have been overridden' on subsequent screens. You can select option R to reset values to the new default, or Y to review or modify those values.
The panel shown in Figure B-3 is displayed when you press Enter to confirm your
component selections.
Figure B-3. Installation Environment Panel
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services
Please enter the following parameters.
Do you want to enter SMS parameters? NO
DASD Unit: SYSDA
DASD Volser (optional):
SMP/E Work Unit: SYSDA
DASD DSN High Level Qualifier
GLOBAL SMP/E dataset High-level Qualifier: COMPWARE.GLOBAL
Press Enter to continue, PF1 for help, or END to return to previous panel.
Installing CSS, LMS, and HCI Using ISPF
B-5
This panel prompts you to enter information about the installation environment. Notice that the names of the components selected for installation are listed below the
Command prompt. Those names will remain there during the rest of this procedure.
1. Enter the fields for this screen as follows:
SMS Parameters
If you specify YES in the SMS Parameters field, you will be prompted to enter SMS
(Storage Management Subsystem) parameters on the next panel. Depending on your site’s SMS installation options, default SMS parameters may be supplied automatically. In this case, you may not need to specify SMS parameters to the
Installation JCL Customization Facility. If you want to supply SMS parameters, specify YES in this field. Otherwise specify NO. The default value is NO.
DASD Unit
Enter a valid DASD unit name. The value of this field will be used in the UNIT= parameter of the DD statements that allocate non-VSAM libraries and datasets.
The default value is SYSDA.
DASD Volser
This field is optional. If a volume is specified, SMP/E will use it as the target for library and dataset allocation.
SMP/E Work Unit
Enter the name of a DASD unit to use for allocating SMP/E work files. The default value is VIO.
DASD DSN High Level Qualifier
Enter the High-level-qualifier of the datasets created by the download procedure.
See the CD Download or FTP Download procedure instructions.
Global SMP/E dataset High-Level Qualifier
Enter a value to be used for generating the names of the SMP/E system datasets.
These datasets include SMPLOG, SMPPTS, SMPTLIB, and the Global Consolidated
Software Inventory (CSI).
Note: Due to limits on the length of the DSPREFIX parameter (used to build the
SMPTLIB names for SMP/E RELFILES), this field cannot be longer than 26 characters.
2. When you have completed the fields as required, press Enter to continue, then proceed with Step 4.
Step 4. Specify SMS Parameters
If, in the previous step, you did not specify that you wanted to enter SMS parameters, this panel will not appear. Therefore, you can skip this step.
If you specified, on the Installation Environment Panel (Figure B-3 on page B-4), that you
wanted to enter SMS parameters, the panel shown in Figure B-4 is displayed when you
press Enter.
B-6
Enterprise Common Components Installation and Customization Guide
Figure B-4. Specifying SMS Parameters
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services License Management
Host Communications Intf.
Enter any or all of the following SMS parameters.
Data Class: dataclas
Storage Class: storclas
Management Class: mgmtclas
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the data class, storage class, and/or management class parameters for the SMS operating environment as follows:
Data Class
Specify the eight-character data class name for SMS.
Storage Class
Specify the eight-character storage class name for SMS.
Management Class
Specify the eight-character management class name for SMS.
2. When you complete the fields as required, press Enter to continue.
Step 5. Specify Global CSI Dataset Name
The panel shown in Figure B-5 is displayed when you pressed Enter in the previous step.
Figure B-5. Verifying Global CSI Dataset Name c Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services License Management
Host Communications Intf.
The following dataset name will be used for the Global CSI:
COMPWARE.GLOBAL.CSI
If you do not want to use this CSI, type in a new CSI name.
Erase the field to set it to the default.
The dataset currently does not exist.
Modify detail values for Global SMP/E datasets Yes/No/Reset? N
Default values have been overridden
Press Enter to continue, PF1 for help, or END to return to previous panel.
Installing CSS, LMS, and HCI Using ISPF
B-7
Note: The DSN for a new global CSI cannot exceed 38 characters. If the global CSI is predefined outside of the Customization Facility, it can consist of up to 44 characters.
1. Verify that the global CSI dataset name is correct. Change the name or specify a new name if necessary.
2. You can modify or enter detail values for Global SMP/E datasets by specifying Y (yes).
3. To reset any overridden detail values to default, specify R (reset).
4. Press Enter to continue.
The Installation JCL Customization Facility determines whether the dataset currently exists. One of the following will occur:
If: Then:
The dataset exists but has not been set up for use with Compuware products.
A jobstream is generated to add the appropriate parameters to the CSI.
This job is named $xxI0GBA, where xx specifies the components you are installing:
• CS for CSS only
• LM for LMS only
• HC for HCI only
• EC for two or more of the above components
Review the resulting jobstream and compare the generated parameters to any existing SMP/E parameters.
The dataset exists and is already set up for use with
Compuware products.
Job $xxI0GBA is not created.
The dataset does not exist.
Jobstream $xxI0GBA is generated to build the dataset and initialize it with the required Compuware SMP/E parameters.
Step 6. Modify Detail Values for Global SMP/E Datasets
If you entered Y (yes) to modify detail values for Global SMP/E datasets, the following screen displays. If you did not, skip to the next step.
Figure B-6. Modify Global SMP/E Detail Values
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services License Management
Host Communications Intf.
Reset any field to default by clearing it
GBLCSI: CPWR.GBLHLQ.CSI
VOLSER: xxxxxx DASD Unit: SYSDA
SMS... Dataclass: xxxxxxxx Mgmtclass: xxxxxxxx Storclass: xxxxxxxx
SMPLOG: CPWR.GBLHLQ.SMPLOG
SMPPTS: CPWR.GBLHLQ.SMPPTS
VOLSER: xxxxxx DASD Unit: SYSDA
SMS... Dataclass: xxxxxxxx Mgmtclass: xxxxxxxx Storclass: xxxxxxxx
SMPTLIB (DSPREFIX): CPWR.GBLHLQ
VOLSER: xxxxxx DASD Unit: SYSDA
SMP/E DASD Work Unit: VIO
Press Enter to continue, PF1 for help, or END to return to previous panel.
B-8
Enterprise Common Components Installation and Customization Guide
Detail values for the Global CSI and other SMP/E Global datasets can be entered on this screen. Individual fields can be reset to the default value by clearing them.
Detail values can be entered for the following groups:
• Global CSI
• SMPLOG/SMPPTS
• SMPTLIB (DSPREFIX)
• DASD unit for Global SMP/E work files
Overtype the fields with desired values. The value for SMPTLIB (DSPREFIX) can be changed by returning to the Global Options screen and changing the value for Global
SMP/E High Level Qualifier.
Step 7. Specify Jobcard Information
The panel shown in Figure B-7 is displayed when you pressed Enter in the previous step.
It prompts you for assembler and job card information.
Figure B-7. Entering Assembler and Job Card Information
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services License Management
Host Communications Intf.
Enter Job Card Information:
//$$$$$$$$ JOB ('ACCT'),'USER NAME',
// CLASS=?,MSGCLASS=?,NOTIFY=PROGRAMMER
//* OPTIONAL JES PARAMETER CARD COULD GO HERE
//*
//*
NOTE: The class selected MUST allow enough CPU time for long running jobs.
Jobs $xxI2APL and $xxI3ACC can easily exceed 5 CPU minutes each.
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the job card information for the Installation JCL Customization Facility as follows:
Job Card Information
Update the supplied model job card to follow your site standards. You may enter up to five lines of job information.
By default, the installation facility will set the $$$$$$$$ value equal to the member name of each job created. You also have the option of specifying the job name using the format xxxxxxx$ or xxxxxxxx, where the x’s are whatever name you choose. If you set it to xxxxxxx$, the installation facility will set the job name for each job to xxxxxxx and append a number to it. A letter will be appended for jobs 10 and above. If you set it to xxxxxxxx, the installation facility will use the specified name for all jobs created.
Note: The job class specified must allow enough CPU time for long-running jobs.
2. After you have supplied the required information, press Enter to continue.
Installing CSS, LMS, and HCI Using ISPF
B-9
Step 8. Specify Component SMP/E High-Level Qualifiers
The panel shown in Figure B-8 is displayed when you pressed Enter in the previous step.
It prompts you for the SMP/E high-level qualifiers of the components previously selected for installation.
Figure B-8. Specifying SMP/E High-Level Qualifiers
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services License Management
Host Communications Intf.
Enter the following information:
Compuware Shared Services
SMP/E Dataset High-level Qualifier: COMPWARE.MLCXnnn
License Management
SMP/E Dataset High-level Qualifier: COMPWARE.MLMSnnn
Host Communications Intf.
SMP/E Dataset High-level Qualifier: COMPWARE.MLHCnnn
Press Enter to continue, PF1 for help, or END to return to previous panel.
Note: If a high-level qualifier is longer than 28 characters, the installation facility is not able to generate a default dataset name for the target and distribution zones. You can either change the high-level qualifier entered, or manually modify the zone dataset names to valid lengths.
1. Specify the CSS, LMS, and/or HCI high-level qualifiers as applicable for your installation as follows:
For each component, enter a value to be used in generating names of the specific datasets, including target and distribution zone CSIs, and their respective non-SMP/E target and distribution libraries. The value entered cannot exceed 35 characters.
2. After you supply the appropriate high-level qualifiers, press Enter. You will be prompted for the CSS, LMS, and/or HCI target and distribution zones, depending on which components you are installing.
3. Continue with the appropriate steps below, skipping any that do not apply.
Step 9. Specify CSS Target and Distribution Zones
If CSS was not selected for install, this panel will not appear, you may skip this step.
If you are installing the CSS component, you will be prompted to specify the CSS
target and distribution zones as shown in Figure B-9.
B-10
Enterprise Common Components Installation and Customization Guide
Figure B-9. Specifying CSS Target and Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services License Management
Host Communications Intf.
Enter the following information for Compuware Shared Services
Distribution Zone Name: LCXnnnD
DZone CSI_Dataset Name: COMPWARE.MLCXnnn.DZONE.CSI
DZone CSI currently does not exist
Target Zone Name: LCXnnnT
TZone CSI Dataset Name: COMPWARE.MLCXnnn.TZONE.CSI
TZone CSI currently does not exist
Japanese Language Support? NO
Modify detail value for Component datasets Yes/No/Reset? N
Default values are being used
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the CSS target and distribution zone information as follows, you can reset a field to its default value by clearing it:
Distribution Zone Name
Specifies the name of the SMP/E distribution zone used by CSS. The name you specify must be unique within the global zone. The default is LCXnnnD.
DZone CSI Dataset Name
Specifies the dataset name of the SMP/E distribution zone used by CSS. The default is COMPWARE.MLCXnnn.DZONE.CSI.
DZone CSI Currently exists/does not exist
Indicates whether the CSS distribution zone CSI dataset exists.
Target Zone Name
Specifies the name of the SMP/E target zone used by CSS. The name you specify must be unique within the global zone. The default is LCXnnnT.
TZone CSI Dataset Name
Specifies the dataset name of the SMP/E target zone used by CSS. The default is
COMPWARE.MLCXnnn.TZONE.CSI.
Target CSI Currently exists/does not exist
Indicates whether the CSS target zone CSI dataset exists.
Japanese Language Support
CSS can allocate message and panel libraries to display Japanese language characters rather than English. Specify YES to allocate and install the Japanese language message and panel libraries. Specify NO to bypass allocating these libraries.
Warning: Dzone and/or Tzone name differ from default for CSS release x.y.
You will get this warning message only if the distribution and/or target zone names entered are different from the default.
Note: If either the Target or Distribution CSI's already exist, the following screen will display.
Installing CSS, LMS, and HCI Using ISPF
B-11
Figure B-10. Installing into Pre-existing Target/Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility - Tutorial
CAUTION. The CSI(s) for either or both the Target and Distribution Zones
already exist. If you are installing into an existing set of Target and
Distribution Zones, there is a possibility of destroying data in or related
to the existing Zones.
Compuware strongly suggests you install components into new Zones.
If you try to install a component into the same Zones in a pre-existing CSI,
the SMPMCS for ECC is designed to delete previous releases of that component.
To install a new release of a component into a CSI without deleting previous
releases, you must install using a different Zone Name (default).
2. You can modify or enter detail values for Component datasets by specifying Y (yes).
3. To reset any overridden detail values to default, specify R (reset).
4. After you supply the appropriate information, press Enter. You may be prompted for the LMS, and/or HCI target and distribution zones, depending on which components you are installing.
5. Continue with the next appropriate steps, skipping any that do not apply.
Step 10. Modify Detail Values for Component Datasets
If you entered Y (yes) to modify detail values for Component datasets, the following screens will display. If you did not, skip to the next step.
Figure B-11. Modify Detail Values for Component Datasets
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Modify Detail Dataset information for Compuware Shared Services
1. Distribution Zone Datasets Details
2. Target Zone Datasets Details
3. SMP/E Work Datasets Details
Press Enter to continue, PF1 for help, or END to return to previous panel.
Detail values for the Component and SMP/E work datasets can be entered or modified by entering 1, 2, or 3 on this screen. The appropriate panel will be displayed:
B-12
Enterprise Common Components Installation and Customization Guide
Figure B-12. Component Distribution Zone Detail Value Entry
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Enter Distribution Zone Details for Compuware Shared Services
(Clear a field to reset to default value)
Zone Name: LCXnnnD DSN: COMPWARE.MLCXnnn.DZONE.CSI
Zone VOLSER: xxxxxx DASD Unit: SYSDA
SMS... Dataclass: xxxxxxxx Mgmtclass: xxxxxxxx Storclass: xxxxxxxx
Library VOLSER: xxxxxx DASD Unit: SYSDA
SMS... Dataclass: xxxxxxxx Mgmtclass: xxxxxxxx Storclass: xxxxxxxx
ALCXCNTL DSN: COMPWARE.MLCXnnn.ALCXCNTL
ALCXEXEC DSN: COMPWARE.MLCXnnn.ALCXEXEC
ALCXLOAD DSN: COMPWARE.MLCXnnn.ALCXLOAD
ALCXMENU DSN: COMPWARE.MLCXnnn.ALCXMENU
ALCXMJPN DSN: COMPWARE.MLCXnnn.ALCXMJPN
ALCXPENU DSN: COMPWARE.MLCXnnn.ALCXPENU
ALCXPJPN DSN: COMPWARE.MLCXnnn.ALCXPJPN
ALCXSENU DSN: COMPWARE.MLCXnnn.ALCXSENU
ALCXSJPN DSN: COMPWARE.MLCXnnn.ALCXSJPN
Enter desired value or clear individual fields to reset them to defaults.
Figure B-13. Component Target Zone Detail Value Entry
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Enter Target Zone Details for Compuware Shared Services
(Clear a field to reset to default value)
Zone Name: LCXnnnT DSN: COMPWARE.MLCXnnn.TZONE.CSI
Zone VOLSER: xxxxxx DASD Unit: SYSDA
SMS... Dataclass: xxxxxxxx Mgmtclass: xxxxxxxx Storclass: xxxxxxxx
Library VOLSER: xxxxxx DASD Unit: SYSDA
SMS... Dataclass: xxxxxxxx Mgmtclass: xxxxxxxx Storclass: xxxxxxxx
SLCXAUTH DSN: COMPWARE.MLCXnnn.SLCXAUTH
SLCXCNTL DSN: COMPWARE.MLCXnnn.SLCXCNTL
SLCXEXEC DSN: COMPWARE.MLCXnnn.SLCXEXEC
SLCXLOAD DSN: COMPWARE.MLCXnnn.SLCXLOAD
SLCXMENU DSN: COMPWARE.MLCXnnn.SLCXMENU
SLCXMJPN DSN: COMPWARE.MLCXnnn.SLCXMJPN
SLCXPENU DSN: COMPWARE.MLCXnnn.SLCXPENU
SLCXPJPN DSN: COMPWARE.MLCXnnn.SLCXPJPN
SLCXSENU DSN: COMPWARE.MLCXnnn.SLCXSENU
SLCXSJPN DSN: COMPWARE.MLCXnnn.SLCXSJPN
Enter desired value or clear individual fields to reset them to defaults.
Installing CSS, LMS, and HCI Using ISPF
B-13
Figure B-14. Component SMP/E Work Dataset Detail Value Entry
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Enter SMP/E-Work Dataset Details for Compuware Shared Services
(Clear a field to reset to default value)
SMPMTS COMPWARE.MLCXnnn.SMPMTS
SMPSCDS COMPWARE.MLCXnnn.SMPSCDS
SMPSTS COMPWARE.MLCXnnn.SMPSTS
VOLSER: xxxxxx DASD Unit: SYSDA
SMS... Dataclass: xxxxxxxx Mgmtclass: xxxxxxxx Storclass: xxxxxxxx
SMPWRKn/SYSUTn DASD Unit: VIO
SYSPUNCH DASD Unit: SYSDA
Press Enter to continue, PF1 for help, or END to return to previous panel.
Enter desired value or clear individual fields to reset them to defaults.
Step 11. Specify LMS Target and Distribution Zones
If LMS was not selected for install, this panel will not appear, you may skip this step.
If you are installing LMS, you will be prompted to specify the LMS target and distribution
zones as shown in Figure B-15.
Figure B-15. Specifying the LMS Target and Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services License Management
Host Communications Intf.
Enter the following information for License Management
Distribution Zone Name: LMSnnnD
DZone CSI Dataset Name: COMPWARE.MLMSnnn.DZONE.CSI
DZone CSI currently does not exist
Target Zone Name: LMSnnnT
TZone CSI Dataset Name: COMPWARE.MLMSnnn.TZONE.CSI
TZone CSI currently does not exist
Modify detail values for Component datasets Yes/No/Reset? N
Default values have been overridden
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify the LMS target and distribution zone information as follows, you can reset a field to its default value by clearing it:
Distribution Zone Name
Specifies the name of the SMP/E distribution zone used by LMS. The name you specify must be unique within the global zone. The default is LMSnnnD.
DZone CSI Dataset Name
B-14
Enterprise Common Components Installation and Customization Guide
Specifies the dataset name of the SMP/E distribution zone used by LMS. The default is COMPWARE.MLMSnnn.DZONE.CSI.
Distribution CSI Currently exists/does not exist
Indicates whether the distribution zone CSI dataset exists.
Target Zone Name
Specifies the name of the SMP/E target zone used by LMS. The name you specify must be unique within the global zone. The default is LMSnnnT.
Target Zone CSI Dataset Name
Specifies the dataset name of the SMP/E target zone used by LMS. The default is
COMPWARE.MLMSnnn.TZONE.CSI.
Target CSI Currently exists/does not exist
Indicates whether the target zone CSI dataset exists.
Warning: Dzone and/or Tzone name differ from default for LMS release x.y
You will get this warning message only if the distribution and/or target zone names entered are different from the default.
Note: If either the Target or Distribution CSI's already exist, the following screen will display.
Figure B-16. Installing into Pre-existing Target/Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility - Tutorial
CAUTION. The CSI(s) for either or both the Target and Distribution Zones
already exist. If you are installing into an existing set of Target and
Distribution Zones, there is a possibility of destroying data in or related
to the existing Zones.
Compuware strongly suggests you install components into new Zones.
If you try to install a component into the same Zones in a pre-existing CSI,
the SMPMCS for ECC is designed to delete previous releases of that component.
To install a new release of a component into a CSI without deleting previous
releases, you must install using a different Zone Name (default).
2. You can modify or enter detail values for Component datasets by specifying Y (yes).
3. To reset any overridden detail values to default, specify R (reset).
If you entered Y (yes) to modify detail values for Component datasets, see “Step 10.
Modify Detail Values for Component Datasets” on page B-11.
Step 12. Specify HCI Target and Distribution Zones
If Host Communications Interface (HCI) was not selected for install, the associated panel will not appear, you may skip this step.
HCI is required if you are installing Abend-AID for CICS or Abend-AID. Refer to the
Abend-AID for CICS Installation and Customization Guide or Abend-AID User/Reference Guide for information on installing and customizing this component.
If you are installing the HCI component, you will be prompted to specify the target and
distribution zones as shown in Figure B-17.
Installing CSS, LMS, and HCI Using ISPF
B-15
Figure B-17. Specifying HCI Target and Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Command ==>
Customizing: Compuware Shared Services License Management
Host Communications Intf.
Enter the following information for Host Communications Intf.
Distribution Zone Name: LHCnnnD
DZone CSI Dataset Name: COMPWARE.MLHCnnn.DZONE.CSI
DZone CSI currently does not exist
Target Zone Name: LHCnnnT
TZone CSI Dataset Name: COMPWARE.MLHCnnn.TZONE.CSI
TZone CSI currently does not exist
Modify detail values for Component datasets Yes/No/Reset? N
Default values have been overridden
Press Enter to continue, PF1 for help, or END to return to previous panel.
1. Specify HCI target and distribution zone information as follows, you can reset a field to its default value by clearing it:
Distribution Zone Name
Specifies the name of the SMP/E distribution zone used by HCI. The name you specify must be unique within the global zone. The default is LHCnnnD.
DZone CSI Dataset Name
Specifies the dataset name of the SMP/E distribution zone used by HCI. The default is COMPWARE.MLHCnnn.DZONE.CSI.
Distribution CSI Currently exists/does not exist
Indicates whether the HCI distribution zone CSI dataset exists.
Target Zone Name
Specifies the name of the SMP/E target zone used by HCI. The name you specify must be unique within the global zone. The default is LHCnnnT.
Target Zone CSI Dataset Name
Specifies the dataset name of the SMP/E target zone used by HCI. The default is
COMPWARE.MLHCnnn.TZONE.CSI.
Target CSI Currently exists/does not exist
Indicates whether the target zone CSI dataset exists.
Warning: Dzone and/or Tzone name differ from default for HCI release x.y.
You will get this warning message only if the distribution and/or target zone names entered are different from the default.
Note: If either the Target or Distribution CSI's already exist, the following screen will display.
B-16
Enterprise Common Components Installation and Customization Guide
Figure B-18. Installing into Pre-existing Target/Distribution Zones
Enterprise Common Components
SMP/E Installation JCL Customization Facility - Tutorial
CAUTION. The CSI(s) for either or both the Target and Distribution Zones
already exist. If you are installing into an existing set of Target and
Distribution Zones, there is a possibility of destroying data in or related
to the existing Zones.
Compuware strongly suggests you install components into new Zones.
If you try to install a component into the same Zones in a pre-existing CSI,
the SMPMCS for ECC is designed to delete previous releases of that component.
To install a new release of a component into a CSI without deleting previous
releases, you must install using a different Zone Name (default).
2. You can modify or enter detail values for Component datasets by specifying Y (yes)
3. To reset any overridden detail values to default, specify R (reset)
If you entered Y (yes) to modify detail values for Component datasets, see “Step 10.
Modify Detail Values for Component Datasets” on page B-11.
Step 13. Verify Installation Information
When you pressed Enter in the previous step, the first of a series of confirmation panels was displayed. These panels verify all of the information you have entered up to this point.
• To accept the information on each confirmation panel, press Enter.
• To correct a particular parameter, press END to return to the associated entry panel.
After you accept the information on each of the confirmation panels, the installation process will continue.
Step 14. Process the JCL
The panel shown in Figure B-19 is displayed when you pressed Enter the final time in the
previous step.
Figure B-19. Confirming JCL Processing
Enterprise Common Components
SMP/E Installation JCL Customization Facility
Processing Verification Screen
Command ==>
Customizing: Compuware Shared Services License Management
Press Enter to begin customizing the JCL.
1. Press Enter to start the processing that builds customized JCL members. Press END to cancel the installation.
When you press Enter, the progress of the JCL customization process is displayed on the screen. After the installation JCL has been created, a panel is displayed informing
Installing CSS, LMS, and HCI Using ISPF
B-17
you that a parameter report has been generated (Figure B-20). This report details the
JCL created and lists the parameters and execution information used during installation.
Figure B-20. Report Member Detailing JCL Processing
Enterprise Common Components
SMP/E Installation JCL Customization Facility
The following PDS member contains a report of all parameters used during
customization and a log of all JCL members created:
hlq.CPWR.CYnnnnnn.INS($$xxRPT)
Press Enter to browse the report, END to exit.
2. If you want to browse the report at this time, press Enter. You can also examine the report later by accessing the applicable installation library report member shown on this panel:
– CSREPORT (CSS only)
– LMREPORT (LMS only)
– HCREPORT (HCI only)
– ECREPORT (Two or more components)
3. The processing of the Installation JCL Customization Facility is now finished. Press
END to exit.
Jobs Created by the Installation JCL Customization Facility
All of the jobs created during installation customization are described below. Note that in addition to component-specific jobs, a series of jobs used during the maintenance cycle are also created. See “Maintenance Jobs” on page B-18 for more information.
Jobs Common to All Components
The jobs in this section are customized for use when you install an ECC component. The
xx that appears in the job names is replaced with a two-letter code during installation.
Which two-letter code is used depends on which components you are installing:
• CS (CSS only)
• LM (LMS only)
• HC (HCI only)
• EC (Two or more components)
$xxI0GBA
Allocates and/or initializes the Compuware Global CSI and Global SMP/E datasets.
$xxI1PRA
$xxI1PRB
$xxI2RCV
Note: This job is not built if the Global CSI already exists and you indicate it is already set up for Compuware use.
Allocates the CSS, LMS, and/or HCI libraries and SMP/E datasets.
Initializes the CSS, LMS, and/or HCI SMP/E target and distribution zone
CSIs. It then adds the required CSS, LMS, and/or HCI entries to the
Global Zone CSI.
Receives the CSS, LMS, and/or HCI base code and maintenance.
B-18
Enterprise Common Components Installation and Customization Guide
$xxI3APL
Applies the CSS, LMS, and/or HCI base code and maintenance.
$xxI4ACC
Accepts the CSS, LMS, and/or HCI base code and maintenance.
$PRTABS
Optional job to print abstracts of all PTFs in the maintenance file.
$RSTABS
JCL to unload current PTF abstracts from an installation or maintenance
Tape.
CSS Installation Jobs
The following jobs are customized for installing CSS only.
$CSPABS
$CSLPTFS
Optional job that lists current CSS PTF abstracts.
Lists all PTFs applied to the CSS target and distribution zones. This optional job is for reporting purposes only.
LMS Installation Jobs
The following jobs are customized for installing LMS only.
$LMPABS
Optional job that lists current LMS PTF abstracts.
$LMLPTFS
Lists all PTFs applied to LMS target and distribution zones. This optional job is for reporting purposes only.
HCI Installation Jobs
The following jobs are customized for installing HCI only.
$HCPABS
Optional job that lists current HCI PTF abstracts.
$HCLPTFS
Lists all PTFs applied to the HCI target and distribution zones. This optional job is for reporting purposes only.
Maintenance Jobs
The following jobs may also be built by the installation facility but are used for applying maintenance PTFs. These jobs are used when maintenance is applied. For more
information on applying maintenance, refer to Chapter 4, “Applying Maintenance”.
CSS Jobs
• $CSM0RCV
• $CSM2APL
• $CSM3ACC
LMS Jobs
• $LMM0RCV
• $LMM2APL
• $LMM3ACC
HCI Jobs
• $HCM0RCV
• $HCM2APL
• $HCM3ACC
Installing CSS, LMS, and HCI Using ISPF
B-19
Step 15. Allocate Compuware Global CSI and SMP/E
Datasets
Note: If your site previously installed a Compuware product using SMP/E, skip this step.
This step allocates and initializes the Compuware Global CSI for use with SMP/E. It also allocates the SMPLOG and SMPPTS datasets. For more information on these datasets,
refer to Table 2-3 on page 2-8.
The installation facility has created a job to allocate the required datasets based on which components were chosen for installation at your site:
$CSI0GBA (CSS only)
$LMI0GBA (LMS only)
$HCI0GBA (HCI only)
$ECI0GBA (Two or more components)
1. Review the appropriate job for any necessary changes.
2. Submit the job to start the allocation process.
Step 16. Allocate Libraries and SMP/E Datasets
This step allocates target and distribution zone CSIs as well as product-specific SMP/E datasets.
The installation facility has created a job to allocate the required libraries and datasets based on which components were chosen for installation at your site:
$CSI1PRA (CSS only)
$LMI1PRA (LMS only)
$HCI1PRA (HCI only)
$ECI1PRA (Two or more components)
Note: The space allocations used are based on 3390 DASD. If you use 3380 DASD, you may decide to change the BLKSIZE for the load library and APF authorized load library to 23476 for a better blocking factor.
1. Review the appropriate job for any necessary changes.
2. Submit the job to start the allocation process.
Step 17. Initialize the Target and Distribution Zone CSIs
This step initializes the CSS, LMS, and/or HCI target and distribution zone CSIs.
The installation facility has created a job to initialize the target and distribution zone
CSIs based on which components were chosen for installation at your site:
$CSI1PRB (CSS only)
$LMI1PRB (LMS only)
$HCI1PRB (HCI only)
$ECI1PRB (Two or more components)
B-20
Enterprise Common Components Installation and Customization Guide
1. Review the appropriate job for any necessary changes.
Note: Before you submit this job, make sure the job submitted in the previous step has completed.
2. Submit the job to start the initialization process.
Note: This job may return RC=4 if either of the following messages are issued:
GIM56501W THE aaaaaa SUBENTRY WAS ADDED RATHER THAN REPLACED BECAUSE IT
DID NOT EXIST.
GIM27701W aaaaaa ENTRY bbbbbbb WAS ADDED RATHER THAN REPLACED BECAUSE
IT DID NOT EXIST.
Otherwise, the return code should be 0. These messages can be ignored.
Step 18. Receive the Base Code and Maintenance PTFs
This step receives the CSS, LMS, and/or HCI base code and maintenance PTFs from the
SMP/E files into the SMPPTS and SMPTLIBs.
The installation facility has created a job to receive the base code and maintenance PTFs and to accept the base code depending on which components were chosen for installation at your site:
$CSI2RCV (CSS only)
$LMI2RCV (LMS only)
$HCI2RCV (HCI only)
$ECI2RCV (Two or more components)
1. Review the appropriate job for any necessary changes.
2. Submit the job to start the initialization process.
3. Review any HOLDDATA listed by the job (if any) and take appropriate actions.
4. This job may return RC=4 in step RCVMAINT if there are no holds to be listed.
CAUTION:
Be sure to run the Receive job(s) in a job class suitable for long-running batch jobs.
Step 19. Apply Base Code and Maintenance PTFs to
Target Libraries
This step applies the CSS, LMS, and/or HCI base code and maintenance PTFs to the target zones.
The installation facility has created a job to apply the base code to the target zone depending on which components were chosen for installation at your site:
$CSI3APL (CSS only)
$LMI3APL (LMS only)
$HCI3APL (HCI only)
$ECI3APL (Two or more components)
1. Review the appropriate job for any necessary changes.
Installing CSS, LMS, and HCI Using ISPF
B-21
2. Submit the job to Apply the base code and maintenance PTFs.
CAUTION:
Be sure to run $CSI3APL, $LMI3APL, $HCI3APL, or $ECI3APL in a job class suitable for long-running batch jobs.
Notes:
1. During maintenance Apply, various libraries may fill up (especially the load libraries), and you will receive the following messages:
GIM44001I SYSTEM ABEND D37 OCCURRED WITH A REASON CODE OF '00000004'X...
GIM43903I RETRY PROCESSING WILL BE ATTEMPTED...
GIM30302I COMPRESS PROCESSING WAS SUCCESSFUL...
As long as the 3rd message indicates compressing was successful, then these messages can be ignored.
2. If the HOLDDATA file from Step 18 is not empty, then the Maintenance Apply Step could receive a return code=4. This is normal and can be ignored.
3. The following message may be issued during the APPLY processing and can be ignored if the return code is not greater than 04:
GIM23903W LINK-EDIT PROCESSING FOR SYSMOD xxxxxxxx WAS SUCCESSFUL FOR
MODULE mmmmmmmm IN LMOD llllllll IN THE yyyyyyyy LIBRARY.
THE RETURN CODE WAS nn.
4. The following message may be issued during the APPLY processing of the HCI component and can be ignored:
IEW2609W 5104 SECTION HCISCPIC USABILITY ATTRIBUTE OF NON-REUSABLE
CONFLICTS WITH REQUESTED USABILITY OF REENTRANT.
IEW2454W 9203 SYMBOL xxxxxxxx UNRESOLVED. NO AUTOCALL (NCAL) SPECIFIED.
Step 20. Accept the Base Code and Maintenance PTFs to the Distribution Libraries
This step accepts the CSS, LMS, and/or HCI base code and maintenance PTFs into the distribution libraries.
The installation facility has created a job to accept the base code into the distribution libraries depending on which components were chosen for installation at your site:
$CSI4ACC (CSS only)
$LMI4ACC (LMS only)
$HCI4ACC (HCI only)
$ECI4ACC (Two or more components)
1. Review the appropriate job for any necessary changes.
2. Submit the job to Accept the base code and maintenance PTFs.
CAUTION:
Be sure to run $CSI4ACC, $LMI4ACC, $HCI4ACC, or $ECI4ACC, in a job class suitable for long-running batch jobs.
Notes:
This job may return RC=4 if any of the following messages are issued:
B-22
Enterprise Common Components Installation and Customization Guide
GIM24701W SMP/E COULD NOT OBTAIN LINK-EDIT PARAMETERS FOR LOAD MODULE
xxxxxxxx FOR SYSMOD xxxxxxxx. DEFAULTS WERE USED.
GIM23903W LINK-EDIT PROCESSING FOR SYSMOD xxxxxxxx WAS SUCCESSFUL FOR
MODULE mmmmmmmm IN LMOD llllllll IN THE ALCXLOAD LIBRARY.
THE RETURN CODE WAS 04.
During the ACCEPT processing for CSS, individual object modules of a PTF are linked into the ALCXLOAD library. ALCXLOAD is not an executable library. Since CSS specifies the linkedit parm NCAL (meaning “Do not dynamically include modules called external to the one being processed.”), and the fact that some of these modules contain external calls, the binder issues these warning messages. These calls are usually taken care of during the APPLY link edit processing.
These messages can be ignored.
Step 21. Continue Installation and Customization
Now that the component base code and maintenance have been installed, there may be further customization tasks that need to be addressed. Depending on which components you have installed, continue with the following chapters as necessary:
• Chapter 5, “CSS Customization”
• Chapter 6, “LMS Customization”
Notes:
1. If you have installed the Host Communications Interface (HCI) components, you should refer to the appropriate product manual for specific customization/configuration instructions.
2. If you are installing Abend-AID 11.02.00+ or Abend-AID for CICS, refer to the respective installation and customization guides for configuration instructions concerning the HCI libraries.
C-1
Appendix C.
JCL Customization
Appendix A.
This appendix describes usage of the ECC Component JCL Customization screen. This screen will customize JCL members for the selected components by inserting filenames and other information needed by each particular component. It will also generate JCL members on a per-component basis to Receive, Apply, and Accept maintenance from files uploaded from Frontline and/or the Media Browser.
Note: If you have previously installed components from an ECC release, some of the values displayed on these panels may be populated from values stored in the installing user’s TSO profile. Please verify each panel carefully before continuing.
Executing the JCL Customization Screen
1. Enter the TSO EXECUTE command with the dataset name of the installation library followed by $$ECCUST to initiate the JCL Customization screen. For example:
TSO EX 'hlq.CPWR.CYnnnnnn.INS($$ECCUST)' where hlq.CPWR.CYnnnnnn.INS is the name of your installation sample library.
The Installation Customization Facility screen appears (Figure C-1).
Figure C-1. Installation Customization Facility
Compuware Enterprise Common Components Release 3.1
Installation Customization Facility
Command ==>
Enter the Dataset Name of the PDS that contains the stored variables from the
SMP/E JCL Customization process. If the Dataset does not exist or is not
available, enter a DSN to store new variables and enter option C to Create a
new PDS. Enter B to bypass the DSN and continue. If you enter B to bypass
stored variable processing then no variables will be loaded or stored for this
run.
EFHRNC0.ECC310.CY.SMPE.DATA FILE EXISTS
Create or Bypass (C/B).
If the Dataset above is correct, press Enter to validate and/or Continue.
Press PF1 for help, END to exit.
2. Specify the dataset name of the file that contains the stored variables from the SMP/E
JCL Customization screen or the file that was uploaded from the Media Browser.
Variables found in this file will be used to pre-load fields on subsequent screens. If the file is not available, you have the option of creating a new file or skipping the file usage completely.
Press Enter to validate or continue. The Component Selection screen appears (Figure
C-2
Enterprise Common Components Installation and Customization Guide
Figure C-2. Component Selection screen
Compuware Enterprise Common Components Release 3.1
Installation Customization Facility
Command ==>
Place an "S" by one or more of the following components to select that
component for Customization. To deselect a component, delete the "S"
_ Compuware Shared Services 8.8
_ License Management System 4.0
_ Host Communications Intf. 3.0
Press PF1 for help, END to exit.
3. Select the components you want to customize. You can override any pre-selected components. Press Enter to continue. The Maintenance, HOLDDATA, and Global CSI
DSN screen appears (Figure C-3).
Figure C-3. Enter Maintenance, HOLDDATA DSNs, and Global CSI DSN
Compuware Enterprise Common Components Release 3.1
Installation Customization Facility
Command ==>
Enter the following High-Level-Qualifiers and/or DSNs:
Global CSI DSN: EFHRNC0.ECC310.GLOBAL.CSI
DATASET NOT FOUND
Maintenance DSN: EFHRNC0.ECC310.COMPWARE.CY.MAINT
FILE EXISTS
HOLDDATA DSN: EFHRNC0.ECC310.COMPWARE.CY.HOLDDATA
FILE EXISTS
Press Enter to continue, PF1 for help, or END to return to previous panel.
4. Enter the Global CSI DSN, Maintenance DSN, and HOLDDATA DSN. Press Enter to
continue. The screen for entering job card information appears (Figure C-4).
Figure C-4. Enter Job Card Information
Compuware Enterprise Common Components Release 3.1
Installation Customization Facility
Command ==>
Enter Job Card Information:
//EFHRNC0X JOB ('OCXBAS8.8QC',5M),'RANDY CONK',
// CLASS=A,MSGCLASS=R,NOTIFY=&SYSUID
/*JOBPARM S=CW01
//*
//*
Press Enter to continue, PF1 for help, or END to return to previous panel.
JCL Customization
C-3
5. Enter Job card information. Press Enter to continue.
The next series of panels defines Target/Distribution Zone information. Each component has a separate screen that appears only if that component was previously selected.
Figure C-5. Compuware Shared Services Target/Distribution Zone Information
Compuware Enterprise Common Components Release 3.1
Installation Customization Facility
Command ==>
Enter the following information for Compuware Shared Services:
Distribution Zone Name: LCX880D
Target Zone Name: LCX880T
Target Zone Libraries
High-level Qualifier: EFHRNC0.ECC310.MLCX880
Japanese Language Selected: YES
Press Enter to continue, PF1 for help, or END to return to previous panel.
Figure C-6. Host Communications Interface Target/Distribution Zone Information
Compuware Enterprise Common Components Release 3.1
Installation Customization Facility
Command ==>
Enter the following information for Host Communications Interface:
Distribution Zone Name: LHC300D
Target Zone Name: LHC300T
Target Zone Libraries
High-level Qualifier: EFHRNC0.ECC310.MLHC300
Press Enter to continue, PF1 for help, or END to return to previous panel.
Figure C-7. License Management System Target/Distribution Zone Information
Compuware Enterprise Common Components Release 3.1
Installation Customization Facility
Command ==>
Enter the following information for License Management System:
Distribution Zone Name: LMS400D
Target Zone Name: LMS400T
Target Zone Libraries
High-level Qualifier: EFHRNC0.ECC310.MLMS400
Press Enter to continue, PF1 for help, or END to return to previous panel.
C-4
Enterprise Common Components Installation and Customization Guide
6. Verification panels for each of the preceding screens will appear next. If the values on a screen need to be changed, press PF3 to return to that screen.
Figure C-8. Begin Customization screen
Compuware Enterprise Common Components Release 3.1
Installation Customization Facility
Processing Verification Screen
Command ==>
Press Enter to begin customizing the JCL.
After all screens have been verified, the Begin Customization screen will appear.
7. Press PF3 to return to the Maintenance/Global CSI entry panel to make changes or press Enter to begin the JCL customization.
The next screen displays a real-time log of the customization progress.
Figure C-9. Customization Real-Time Log
Compuware Enterprise Common Components Release 3.1
Installation Customization Facility
----------------------------------------------------------------------------
Member: $CXSSAS Job Name: EFHRNC0X - Customized
Member: $CXS0000 Job Name: EFHRNC0X - Customized
Member: $ZIIPINI Job Name: EFHRNC0X - Customized
Member: $LMPABS Job Name: EFHRNC0X - Customized
Member: $LMM1RCV Job Name: EFHRNC0X - Customized
Member: $LMM2APL Job Name: EFHRNC0X - Customized
Member: $LMM3ACC Job Name: EFHRNC0X - Customized
Member: $LMLPTFS Job Name: EFHRNC0X - Customized
Member: $HCPABS Job Name: EFHRNC0X - Customized
Member: $HCM1RCV Job Name: EFHRNC0X - Customized
Member: $HCM2APL Job Name: EFHRNC0X - Customized
Member: $HCM3ACC Job Name: EFHRNC0X - Customized
Member: $HCLPTFS Job Name: EFHRNC0X - Customized
Member: $HCICFG Job Name: EFHRNC0X - Customized
Member: $HCIJCL Job Name: EFHRNC0X - Customized
*** JCL customization process ended at 09:06:40 ***
Press PF1 for help, END to exit.
8. Press PF3 when it ends to proceed to the next screen. You now have an opportunity to display the log information from the JCL customization run you just executed.
Figure C-10. Log Information from JCL Customization Run
Compuware Enterprise Common Components Release 3.1
Installation Customization Facility
The following PDS member contains a report of all parameters used during
customization and a log of all JCL members created:
EFHRNC0.ECC310.COMPWARE.CY030100.INSTALL($$CSTRPT)
Press Enter to browse the report, END to exit.
JCL Customization
C-5
9. Press PF3 repeatedly to exit the customization screen.
After completing the JCL Customization screen, member $ECCOPY will contain a job stream that will copy some of the sample members just created to the sample libraries of each selected component.
C-6
Enterprise Common Components Installation and Customization Guide
D-1
Appendix D.
Compuware Maintenance Utility
Appendix A.
The Compuware Maintenance Utility (CMU) is a program executed through JCL that, by default, generates reports listing all PTFs currently applied to a particular system, for all specified Compuware mainframe products. With the addition of an optional control file
(available from Frontline (
http://go.compuware.com
)), the CMU can produce reports that include a list of PTFs that have not been applied or are otherwise missing. The contents of the control file (Figure D-2) are placed into a dataset or in stream JCL for the CMU to scan.
The CMU is distributed in the License Management System loadlib (SLMSLOAD).
Note: The CMU was introduced in License Management System (LMS) via a PTF in May
2013. Since then, the CMU has been enhanced and requires PTF LMF0064 to support the new control file format. Make sure all current maintenance is applied to LMS before attempting to use the CMU. Refer to the Compuware products listed in the “z/OS, Compatibility and Supported Releases Table” on
Frontline for any additional product PTF requirements.
The CMU processes a simple list of dataset names, which it will scan and report on. The utility is able to scan the system link list for CMU supported Compuware product datasets. It will also scan the STEPLIB DD concatenation of the JCL as well as the datasets specified for SYSIN. The combined scan results from these sources will be presented in the output reports.
JCL Required to Execute the CMU
Several DD statements are required to execute the CMU and some are optional. Sample
JCL is provided in the LMS samples library (SLMSCNTL) member LMMNTUTL. The general JCL structure required is shown below:
Figure D-1. General JCL Structure
//JOBCARD JOB CLASS=A
//MAINT EXEC PGM=LMMNTUTL
//STEPLIB DD DISP=SHR,DSN=COMPWARE.MLMSNNN.SLMSLOAD
//SYSPRINT DD SYSOUT=*
//REPORT DD SYSOUT=*
//ALLPTFS DD SYSOUT=*
//PRODUCTS DD DISP=SHR,DSN=COMPWARE.LM.MAINTCTL(LMMNTCTL)
//SYSIN DD *
product.dataset.name1
product.dataset.name2
product.dataset.namen
/*
//
Required Datasets
STEPLIB — this dataset must point to the License Management System SLMSLOAD library where the CMU resides. Any other Compuware product dataset may optionally be specified in the STEPLIB DD concatenation for scanning and reporting on their contents as well.
D-2
Enterprise Common Components Installation and Customization Guide
SYSPRINT — a required SYSOUT dataset. This output dataset will contain any error messages resulting from the scan.
REPORT — a required SYSOUT dataset. This output dataset will contain the summary "one-page" report for each product dataset found in STEPLIB, SYSIN, or the system link list.
ALLPTFS — a required SYSOUT dataset. This output dataset will contain the full list of applied or missing PTFs for each product dataset found in STEPLIB, SYSIN, or the system link list.
PRODUCTS — this optional input dataset contains the control file information for the CMU. The CMU uses the information in this dataset to determine the highest levels of maintenance that are available for each product. When this dataset is available and processed successfully, the CMU will produce reports based on PTFs that are not yet applied (missing), by product.
When the PRODUCTS DD statement is not present in the JCL, or if the associated dataset was not in the proper format and could not be processed, the CMU will produce the default report based on all of the PTFs that are applied, by product.
The control file input specified by PRODUCTS can be in stream data in the JCL, or be a PDS dataset member. If the control information resides in a physical dataset, the dataset must be 80-byte fixed length records, any valid blocksize.
The format of the control file data is discussed below in “Control File Format”
SYSIN - this is an optional, but recommended, input dataset. This dataset specifies a list of Compuware product dataset load libraries that are to be scanned. If this dataset is coded, the product dataset names should be specified in columns 1 through
44, one dataset per line.
Control File Format
The control file, provided on Frontline (
http://go.compuware.com
), under License
Management System, contains a list of Compuware products and release numbers, which includes a list of all the currently available PTFs for each.
The control file is used by the CMU to determine which PTFs have not yet been applied.
That determination is based on what PTFs are actually applied compared to the inclusion list of all the PTFs that are currently available.
The control file will be updated on Frontline each time maintenance is released for the participating products. Be sure to check for updates before running the utility to ensure the reporting is current.
An example of the control file input is in Figure D-2.
Compuware Maintenance Utility
D-3
Figure D-2. Example of the Control File input
******************************
***** PTF-INCLUDE-LIST *****
******************************
UPDATED 2013 SEP 23
** Compuware Shared Services
*
PRODUCT CX 08.05.00
CXM0001-CXM0097 CXM0099-CXM0101 CXM0103-CXM0141 CXM0143-CXM0408
PRODUCT CX 08.06.00
CXN0001-CXN0088 CXN0090-CXN0526 CXN0528-CXN0559 CXN0561-CXN0575
CXN0577-CXN0593
PRODUCT CX 08.07.00
CXO0001-CXO0071 CXO0073-CXO0080 CXO0082-CXO0105 CXO0108-CXO0418
CXO0420-CXO0480 CXO0482-CXO0741 CXO0743
PRODUCT CX 08.08.00
CXP0001-CXP0119 CXP0121-CXP0180 CXP0182-CXP0287 CXP0289-CXP0446
CXP0448
PRODUCT CX 09.00.00
CXQ0001-CXQ0046 CXQ0048-CXQ0049 CXQ0052
** License Management System
*
PRODUCT LM 04.00.00
LMF0000-LMF0061
** Abend-AID Common
*
PRODUCT AC 12.03.00
* FMID MKAZ231
ACB001Y-ACB002Y ACB004Y ACB006Y ACB008Y-ACB009Y ACB012Y ACB014Y-ACB016Y
ACB020Y ACB022Y ACB027Y-ACB030Y ACB032Y ACB034Y ACB037Y ACB043Y
ACB045Y ACB050Y ACB053Y ACB055Y ACB057Y ACB060Y-ACB061Y ACB065Y
* FMID OKAZ231
ACB004Z ACB006Z ACB008Z-ACB009Z ACB020Z ACB022Z ACB028Z-ACB030Z
** Abend-AID
*
PRODUCT AA 12.03.00
* FMID MPAA230
AAB005Y AAB007Y AAB010Y AAB013Y AAB015Y AAB019Y-AAB023Y AAB026Y
AAB028Y AAB031Y-AAB032Y AAB035Y AAB045Y-AAB048Y AAB050Y-AAB052Y
AAB054Y AAB060Y AAB065Y-AAB066Y
* FMID OPAA230
AAB020Z AAB022Z AAB032Z
** Abend-AID for CICS
*
PRODUCT CF 12.03.00
* FMID MKFX231
CFB003J CFB011J CFB015J CFB018J CFB020J-CFB022J CFB025J CFB044J
CFB050J-CFB051J CFB065J
* FMIDS NKFX232-NKFX236
CFB017*-CFB018* CFB021* CFB024* CFB033* CFB036* CFB038* CFB041*
CFB049*-CFB050* CFB065*
* FMID OKFX231
CFB020A CFB022A
** Fault Analytics
*
PRODUCT MF 12.03.00
MFB002J
******************************
*** END-PTF-INCLUDE-LIST ***
******************************
The control file specifies all CMU supported Compuware mainframe products back to a reasonable release level, typically no more than two releases back from current (n-2).
Lines within the control file that contain an asterisk (*) in column 1 are considered comments and are ignored.
D-4
Enterprise Common Components Installation and Customization Guide
If the CMU is unable to parse the control file information because the format is incorrect or because the information was garbled as a result of download, it will report an error message to SYSPRINT, then produce the default report containing only applied PTFs.
Report Output
Figure D-3 shows the output for the summary report when the CMU is executed without a control file (no PRODUCTS DD statement). Following this summary report, is an example of the output showing the list of PTFs applied (Figure D-4).
Further examples are shown providing a sample of the CMU output with a control file present (Figure D-5 and Figure D-6).
In the reports, if a product dataset was specified in one of the input sources but it could not be identified as a CMU Supported Compuware product dataset (no xxRELSMP-like module), a double-question mark (
??
) will appear in the report for the product code and an
N/A
will appear in the description and release.
If a product dataset was scanned successfully, but that product was not represented in the control file input, then a double-question mark (
??
) will appear in the highest available
PTF column because no control information was available. When this condition occurs, the CMU will also be unable to determine the number of missing PTFs.
Figure D-3. Summary report without a PRODUCTS DD control file
for specified datasets
Compuware Product Maintenance at a Glance
Highest #
Product PTF PTFs
Product code and name Release Applied Applied Source Library
---------------------------- -------- ------- ------- -------- ---------------------
-------------
CX Shared Services 08.07.00 CXO0486 481 STEPLIB CX.PROD.R080700.SLCXLOAD
HC Host Communic. Interface 02.50.00 HCA0045 44 SYS2.HC250.S1.AUTHLIB
?? N/A N/A SYS2.HC250.S2.AUTHLIB
CX Shared Services 08.08.00 CXP0187 186 CX.PROD.R080800.ALLPTFS.SLCXLOAD
CX Shared Services 08.05.00 CXM0413 404 EXPLICIT CX.PROD.R080500.SLCXLOAD
FA File-AID/MVS 09.03.01 FA9A011 9 FA.PUBLIC.V9R3M1T.MXFA931.SXFAAUTH
XT Xpediter/TSO 09.01.00 XTI0056 56 XT.PROD.MLXT910.ALLPTFS.SLXTLOAD
XT Xpediter/TSO 07.06.00 XTF0164 163 XT.PROD.MLXT760.ALLPTFS.SLXTLOAD
XD Xpediter/CICS 09.01.00 XDNL068 66 XD.R090100.NMXD910.SMXD065L
XD Xpediter/CICS 08.03.00 XDMI207 205 XD.R080300.MMXD839.SMXD063L
XG Xpediter/Xchange 05.00.00 XGB0014 14 XG.PROD.MLXG500.ALLPTFS.SLXGLOAD
XG Xpediter/Xchange 04.00.00 XGA0077 71 XG.PROD.MLXG400.ALLPTFS.SLXGLOAD
XV Xpediter/Code Coverage 03.01.00 XVC0041 40 XV.PROD.MLXV310.ALLPTFS.SLXVLOAD
XV Xpediter/Code Coverage 03.00.00 XVB0033 33 XV.PROD.MLXV300.ALLPTFS.SLXVLOAD
CX Shared Services 08.08.00 CXP0142 140 LINKLIST
FA File-AID/MVS 09.03.01 FA9A028 20
Compuware Maintenance Utility
D-5
Figure D-4. Full report without a PRODUCTS DD control file
Compuware Product Maintenance Applied
for specified datasets
CX Shared Services 08.07.00
-------------------------------------------------------------------------
From: STEPLIB DSN: CX.PROD.R080700.ALLPTFS.SLCXLOAD
PTFs applied:
CXO0001 CXO0002 CXO0003 CXO0004 CXO0005 CXO0006 CXO0007 CXO0008 CXO0009
CXO0010 CXO0011 CXO0012 CXO0013 CXO0014 CXO0015 CXO0016 CXO0017 CXO0018
CXO0019 CXO0020 CXO0021 CXO0022 CXO0023 CXO0024 CXO0025 CXO0026 CXO0027
CXO0028 CXO0029 CXO0030 CXO0031 CXO0032 CXO0033 CXO0034 CXO0035 CXO0036
CXO0037 CXO0038 CXO0039 CXO0040 CXO0041 CXO0042 CXO0043 CXO0044 CXO0045
CXO0046 CXO0047 CXO0048 CXO0049 CXO0050 CXO0051 CXO0052 CXO0053 CXO0054
CXO0055 CXO0056 CXO0057 CXO0058 CXO0059 CXO0060 CXO0061 CXO0062 CXO0063
CXO0064 CXO0065 CXO0066 CXO0067 CXO0068 CXO0069 CXO0070 CXO0071
CXO0073 CXO0074 CXO0075 CXO0076 CXO0077 CXO0078 CXO0079
CXO0082 CXO0083 CXO0084 CXO0085 CXO0086 CXO0087 CXO0088 CXO0089 CXO0090
CXO0091 CXO0092 CXO0093 CXO0094 CXO0095 CXO0096 CXO0097 CXO0098 CXO0099
CXO0100 CXO0101 CXO0102 CXO0103 CXO0104 CXO0105 CXO0108
CXO0109 CXO0110 CXO0111 CXO0112 CXO0113 CXO0114 CXO0115 CXO0116 CXO0117
CXO0118 CXO0119 CXO0120 CXO0121 CXO0122 CXO0123 CXO0124 CXO0125 CXO0126
CXO0127 CXO0128 CXO0129 CXO0130 CXO0131 CXO0132 CXO0133 CXO0134 CXO0135
..
.. these lines omitted for brevity
..
CXO0460 CXO0461 CXO0462 CXO0463 CXO0464 CXO0465 CXO0466 CXO0467 CXO0468
CXO0469 CXO0470 CXO0471 CXO0472 CXO0473 CXO0474 CXO0475 CXO0476 CXO0477
CXO0478 CXO0479 CXO0480 CXO0481 CXO0482 CXO0483 CXO0484 CXO0485 CXO0486
D-6
Enterprise Common Components Installation and Customization Guide
Figure D-5. Summary report with a Product DD control File
Compuware Product Maintenance at a Glance
for specified datasets
Highest Highest #
Product PTF PTF PTFs
Product code and name Release Applied Avail Missing Source Library
---------------------------- -------- ------- ------- -------- -------- ----
CX Shared Services 08.07.00 CXO0488 CXO0488 2 STEPLIB CX.PROD.R080700.SLCXLOAD
HC Host Communic. Interface 02.50.00 HCA0045 HCA0045 0 SYS2.HC250.S1.AUTHLIB
?? N/A N/A ?? SYS2.HC250.S2.AUTHLIB
CX Shared Services 08.08.00 CXP0171 CXP0189 23 CX.PROD.R080800.SLCXLOAD
CX Shared Services 08.05.00 CXM0408 CXM0413 15 EXPLICIT CX.PROD.R080500.LOADLIB
FA File-AID/MVS 09.03.01 FA9A027 FA9A028 2 FA.PUBLIC.V9R3M1T.MXFA931.SXFAAUTH
XT Xpediter/TSO 09.01.00 XTI0057 XTI0042 0 XT.PROD.MLXT910.ALLPTFS.SLXTLOAD
XT Xpediter/TSO 07.06.00 XTF0164 XTI0164 1 XT.PROD.MLXT760.ALLPTFS.SLXTLOAD
XD Xpediter/CICS 09.01.00 XDNL068 XD*L070 4 XD.R090100.NMXD910.SMXD065L
XD Xpediter/CICS 09.01.00 XDML068 XD*L070 4 XD.R090100.MMXD910.SMXD064L
XD Xpediter/CICS 08.03.00 XDMI207 XD*I207 2 XD.R080300.MMXD830.SMXD063L
XW DevEnterprise 05.03.00 XWE0026 ?? X2.PROD.MLXW530.ALLPTFS.SLXWLOAD
XG Xpediter/Xchange 05.00.00 XGB0015 XGB0015 0 XG.PROD.MLXG500.ALLPTFS.SLXGLOAD
XG Xpediter/Xchange 04.00.00 XGA0077 XGA0077 6 XG.PROD.MLXG400.ALLPTFS.SLXGLOAD
XV Xpediter/Code Coverage 03.01.00 XVC0041 XVC0041 1 XG.PROD.MLXG310.ALLPTFS.SLXGLOAD
XV Xpediter/Code Coverage 03.00.00 XVB0033 XVB0033 0 XG.PROD.MLXG300.ALLPTFS.SLXGLOAD
CX Shared Services 08.08.00 CXP0142 CXP0189 49 LINKLIS
FA File-AID/MVS 09.03.01 FA9A028 FA9A028 1
}
Figure D-6. Full report with a PRODUCTS DD control file
Compuware Product Maintenance Requirements
for specified datasets
CX Shared Services 08.07.00
-------------------------------------------------------------------------
From: STEPLIB DSN: CX.PROD.R080700.ALLPTFS.SLCXLOAD
PTFs missing:
CXO0080 CXO0081
HC Host Communic. Interface 02.50.00
-------------------------------------------------------------------------
From: STEPLIB DSN: SYS2.HC250.S1.AUTHLIB
PTFs missing:
NONE
CX Shared Services 08.08.00
-------------------------------------------------------------------------
From: STEPLIB DSN: CX.PROD.R080800.SLCXLOAD
PTFs missing:
CXP0086 CXP0164 CXP0168 CXP0169 CXP0170 CXP0172 CXP0173 CXP0174 CXP0175
CXP0176 CXP0177 CXP0178 CXP0179 CXP0180 CXP0181 CXP0182 CXP0183 CXP0184
CXP0185 CXP0186 CXP0187 CXP0188 CXP0189
CX Shared Services 08.05.00
-------------------------------------------------------------------------
From: EXPLICIT DSN: CX.PROD.R080500.LOADLIB
PTFs missing:
CXM0013 CXM0070 CXM0119 CXM0120 CXM0121 CXM0122 CXM0142 CXM0236 CXM0294
CXM0298 CXM0409 CXM0410 CXM0411 CXM0412 CXM0413
FA File-AID/MVS 09.03.01
-------------------------------------------------------------------------
From: EXPLICIT DSN: FA.PUBLIC.V9R3M1T.MXFA931.SXFAAUTH \
PTFs missing:
FA9A007 FA9A028
G-1
Glossary
Abend-AID. The Compuware product for fault diagnosis that provides an immediate, detailed analysis of application program failures in a comprehensive report format.
Abend-AID Fault Analytics. The Compuware
Abend-AID option that assists managers in monitoring, measuring, controlling, and improving the fault resolution process in the IT environment.
Abend-AID Fault Analytics (formerly Abend-AID
Fault Manager) offers comprehensive fault management of the IBM OS/390 , IBM z/OS, Windows
2000/NT, IBM/AIX, HP/UX, and Sun Solaris UNIX environments
Abend-AID for CICS. The Compuware product for fault diagnosis that provides a full range of analysis functions for managing abnormal CICS transaction terminations (abends) and CICS region outages.
Abend-AID for WebSphere (MQ). The Compuware product that enables developers to clearly define reason, return, and error codes, obtain MQ environment information whenever an application fails, and quickly solve enterprise and e-business systems problems. Comprehensive support is provided for WebSphere MQ/MQSeries in batch,
IMS, and CICIS environments.
Abend-AID products. A generic name for the
Abend-AID product family including Abend-AID
(MVS), Abend-AID for CICS, Abend-AID Fault
Manager, and Abend-AID for WebSphere (MQ).
Abend-AID Report. (1) A set of records containing data extracted at abend time from the affected
MVS region and associated control blocks that are stored in the Abend-AID DDIO report file. (2) A readable report produced at view time using the records stored in the Abend-AID DDIO report file.
Abend time. The time when an abend occurs and Abend-AID products perform their analyses.
Allocation group. A set of blocks assigned to a
DDIO file member when the member requires additional storage.
APF Authorization. APF can be used to restrict access to system functions and can require that all modules loaded by an authorized program be loaded from an authorized load library.All modules loaded by LMSINIT must be loaded from authorized load libraries or LMSINIT will fail. Only individuals with proper RACF authority will have permission to update authorized load libraries.
Automatic lock. Automatic locks are created whenever a member is added to a DDIO file format using the AUTODELETE=DUPS or AUTODE-
LETE=STAGED option. The most recent member is automatically locked. See also manual lock.
AUTODELETE. An attribute of a DDIO file, specified during formatting of the file, that determines the action to be taken when the file becomes full and an attempt is made to add a new member to the file.
Base Services. Former ECC component now distributed with Abend-AID Common Components of the Abend-AID product line. It provides basic viewing server-related services enabling the Distributed Viewing Support.
Batch File Utility. A set of CSS utilities used to prepare, maintain, and manipulate DDIO files, shared directories, and databases.
CEC. Central Electronic Complex designates the physical computer which can contain one or more
LPARs. CECs can be of the older type designated as
G1 through G6 or can be the new z/800 or z/900.
CEC Licensing. The number of MSUs provided by that CEC across all LPARs.
CGI. Common Gateway Interface. A way of interfacing computer programs with HTTP or WWW servers, so that a server can offer interactive sites instead of just static text and images.
CGI-bin. Common Gateway Interface-BINaries. A special directory where common gateway interface
(CGI) scripts are kept.
Compuware Shared Services (CSS). A set of components used by several Compuware products to provide storage, retrieval, and maintenance for source listings and diagnostic reports.
Compuware Viewing Facility (Compu-
ware/VF). An online ISPF application, providing menu-driven access to DDIO files such as Abend-
AID reports, databases, shared directories and source listings. Compuware V/F supports online viewing, printing, locking, unlocking and deleting of members in any DDIO file. Most batch utility functions are also available, including creating and deleting databases or shared directories.
G-2
Enterprise Common Components Installation and Customization Guide
Source listings on remote files can be also be viewed.
Customer Modification Facility (CMF). A method for activating specialized code modifications to the CSS base code. This facility can retrofit your restricted zaps from a release prior to CSS 7.4 to the SMP/E environment.
Customized Translation Table. An optional table provided by Compuware customers for translating non-printable characters. It is used by the batch file utility and Compuware/VF for printing or displaying lines containing storage displayed by
Abend-AID products at abend time.
CWAASDUT. The batch file utility used for
Abend-AID shared directories and report databases. CWAASDUT allows you to manage the files used by an Abend-AID shared directory and its associated abend report files. The shared directory is used to process all directory requests related to an abend report file and maintain information about database activity.
CWASSECU. The name of the user-coded Security Exit program.
CWDDALLU. The batch file utility program that can manage all source listing and report file DDIO types previously handled separately by CWAAS-
DUT, CWDDSUTL, CWFXSDUT and CWDDLPUT.
CWDDLPUT. The batch file utility program used to manage source shared directories and databases for all of the supported languages. The shared directory maintains information about source listing processing and database activity.
CWDDSUTL. The program for Compuware/VF and the batch file utility used by Abend-AID, Xpediter/CICS, and Xpediter/TSO. CWDDSUTL allows you to print, delete, lock, unlock, copy, move, import, and export DDIO file. members, and to list
DDIO file directory entries. It also allows you to initially format a DDIO file.
CWFXSDUT. The batch file utility used by
Abend-AID for CICS. CWFXSDUT allows you to manage the files used by a shared directory and its associated transaction databases. The shared directory is used to process all directory requests related to a transaction database.
CWPDDIO. The DDIO file that contains the source member output generated during language processing.
CWPERRM. Dynamically allocated dataset generated during language processing containing all the
CSS messages.
CWPPRMO. A language processor input dataset that contains all of the language processor options. This DD statement can also be used to specify in-stream options.
CWPPRTI. Compiler or assembler listing input to the CSS postprocessor.
CXTRACE. A report that CSS technical support requests to assist in problem resolution. This report traces processing through CSS code and can be a useful tool for determining the cause of an abend.
DBMODEL. The name of an OBJECT that contains the specifications required to create a new source listing database during dynamic database creation (DYNCREATE). The information is stored in the specified source listing shared directory. It is used during language processing to dynamically create a new source listing database to contain the source member if all attached databases are full.
DDIO (Dump Dataset Input Output). A proprietary file access method that stores Abend-AID reports, transaction dump information, and source listings within specially formatted DDIO files for several Compuware products that use CSS. You can allocate DDIO files as VSAM or sequential datasets depending on specific product requirements.
DDIOCALC. An online calculator provided to calculate optimal allocation and formatting parameters for DDIO files. DDIOCALC cannot be used for shared directories.
DDIO File. A generic term that refers to the DDIO database or dataset used to store Abend-AID reports, transaction dump information, or source listings from Compuware products that use CSS.
DDIO File Member. A generic name for an individual diagnostic report in an Abend-AID report file, a source listing in a source listing file, or transaction dump information in a transaction database.
Directory entry. A record in the fixed portion of the DDIO file (Directory) that contains information specific to a member. Each member has a corresponding directory entry. The number of directory entries is specified during formatting of the DDIO file and cannot be changed without reformatting the file.
DIRX Report. A report produced by the DIRX command of the batch file utility or the “I” line command of the Compuware V/F utility panel.
This report contains attribute and alloaction information about the specified DDIO file and a listing of the directory entries.
G-3
Distributed Viewing Support (DVS). Allows
Abend-AID and Abend-AID for CICS users to view both merged and base reports, where either the base report or listing file resides on a remote system. Abend-AID users can have source support across remote MVS systems that don’t share DASD.
DYNCREATE. A term used to denote the
“dynamic database creation” process that can be invoked when using the CSS Language Processor with a source shared directory listed for the compiler output (CWPDDIO). A DBMODEL must first be defined in the desired source shared directory using the batch utility CWDDLPUT or CWD-
DALLU with DYNCREATE=YES specified to allow invoking of the dynamic database creation process. If enough space is not found in any of the attached source listing databases, then the DYN-
CREATE process is invoked. A new source listing database is created and attached, and the new source member is written.
Enhanced Listing. A convenient source of quick reference information and program documentation that merges DMAP and CLIST information, in addition to error and diagnostic messages, with a
COBOL source listing.
Enterprise Common Components (ECC). ECC is the packaging method for the following Compuware facilities:
• Compuware Shared Services (CSS)
• License Management System (LMS)
• Host Communications Interface (HCI)
Entry. A generic name for a transaction diagnostic report in a transaction database for Abend-AID for CICS.
Formatting a DDIO File. The preparation of an allocated VSAM or sequential file to be used as a
DDIO file.
Full DDIO File. A DDIO file for which all allocation groups and/or all directory entries are allocated to members. This scenario invokes the
AUTODELETE process.
Host Communications Interface (HCI). A facility that provides connectivity between mainframebased programmer productivity software and peer node software running on other platforms in a network. It allows application programs to communicate over any one of several protocols without knowledge of which protocol is in use at any given time.
Installation JCL Customization Facility. A CSS facility consisting of a set of screens that prompt you to enter installation information. This information is used to build the jobs necessary to perform the CSS SMP/E installation.
Language Processor (LP). The CSS processor that analyzes and builds Assembler, C, COBOL, or PL/I compiler output into sort work records. The C and
COBOL processors then sort and merge these records with the listing. The Assembler and PL/I processors build an incore symbol table of all the identifiers. Processor control blocks are then generated and written to a source listing DDIO file.
These DDIO members can then be used as input for Compuware products that require this information.
License Administration Utility (LAU). The LAU is the license administration control center for your organization’s IT professional who is responsible for managing your access to Compuware products. The LAU is an ISPF application that enables
• the creation of a License File
• the import of License Certificates into a
License File
• the maintenance and export of a License File
• the reporting and analysis of your License File and License Certificate information in virtual storage
Your organization’s License Administrator will also set up License Management System parameters and system operation options using the LAU.
License Certificate. English-like readable electronic records that contain a portion of the information from your license agreement for a product release’s use at a particular site. The License Certificate is used to update your License File.
License File. Dataset containing imported
License Certificate information for all licensed releases of Compuware products. This file is in
ASCII text format.
License Management System (LMS). Facility that enables you to centrally administer Compuware product License Certificates and manage access to Compuware products at your site. The
LMS includes several components that together enable you to establish, maintain, diagnose, and upgrade access to the Compuware products licensed by your enterprise. The LMS replaces the customer profile utility provided with earlier versions of Compuware mainframe products.
Line command. A command entered next to the line to be processed. A line command is executed only for the specified member.
LMVERIFY. See Verification Report.
G-4
Enterprise Common Components Installation and Customization Guide
Locked member. A DDIO file member that was manually locked using the batch file utility or
Compuware/VF, or automatically locked as a result of AUTODELETE=DUPS or AUTODELETE=STAGED processing. A manually locked member is identified by an M in the directory report or directory screen while an automatically locked member is identified by an L in the directory report or directory screen. When manually locked, a member cannot be automatically deleted when the DDIO file becomes full.
LPAR. Logical Partition is one operating system image, such as OS/390, z/OS, or z/OS-e.
LPAR Licensing. Refers to the defined capacity or
“capped capacity” of the LPAR itself.
Manual lock. A member that was locked using the L line command in Compuware/VF or by using the LOCK batch command. Members that have been manually locked retain their locks during the autodeletion process. See also automatic lock.
MIPS. Millions of Instructions per Second. A unit of measure of processing performance equal to one million instructions per second.
MSU. Millions of Service Units per Hour.
Oldest member. (1) For report files, the diagnostic report with the earliest abend date and time.
(2) For source listing files, the program with the earliest compile date and time.
Primary Command. A command entered in the
COMMAND INPUT field while in TSO.
Problem Documentation Utility. A CSS utility that captures the documentation needed by Compuware for resolving technical issues and problems. This utility allows you to collect the documentation — such as copybooks, SYSPRINT, and DDIO members — that CSS Technical Support requires for problem resolution.
Report File. An Abend-AID DDIO file containing diagnostic reports.
Security Exit Program. A user-coded program that allows or denies execution of a requested command for a selected member by a specific user against particular DDIO files.
Server Grace. The amount of time an LPAR can run without being connected to the server.
Shared Directory. A variable-length record
VSAM RRDS that maintains information about abends and language processing along with the attached database activity. A shared directory can contain Abend-AID for CICS directory records for each region and transaction dump known to a server, Abend-AID directory records for abend report processing, or source listing shared directory records necessary to process source listing database members.
SMP/E. System Modification Program/Extended is IBM’s standard facility for installing and maintaining software modifications in the MVS environment.
Source Listing. A compiled or enhanced listing and additional information about a program, that is stored in a source listing DDIO file.
Source Listing Database. A specially formatted source listing DDIO file, attached to and managed by a source shared directory.
Source Listing File. A DDIO file containing source listings generated by the Language Processor.
STROBE. The STROBE MVS Application Performance Measurement System is a product that determines where and how application time is spent in online regions and batch processing programs and how system resources are used. STROBE collects several types of data as it tracks activity within an MVS environment and produces a collection of reports that helps you determine where to revise applications to improve their performance.
Suppressed statements. Statements that are not displayed in the compiler listing. Suppressed statements in a DDIO source member contain an internal flag that the Xpediter/TSO product can use to display or suppress source statements using the
GEN command.
Transaction Database. A DDIO file, containing transaction dump information, that is managed by a shared directory in Abend-AID for CICS. Multiple entries created from CICS transaction terminations are stored in a single transaction database.
Unlocked Member. A DDIO file member that is not currently locked. The locked member can be unlocked either manually, using the batch file utility or Compuware/VF, or automatically as a result of AUTODELETE=DUPS or AUTODE-
LETE=STAGED processing. An unlocked member in a full DDIO file formatted with AUTODE-
LETE=YES, AUTODELETE=DUPS, or AUTODE-
LETE=STAGED can be automatically deleted when another member is added to the file.
Verification Report (LMVERIFY). Displays the result of a verification program that checks out each product version in cache. This data is exactly what a product would receive when it runs. Run-
ning this report will prove that the License Management System environment is properly set up for the customer.
View time. The time when a diagnostic report or source listing is presented in a readable format for online viewing or printing.
.
G-5
G-6
Enterprise Common Components Installation and Customization Guide
I-1
Index
B
A
Abend-AID for WebSphere (MQ), G-1
Abend-AID report files
allocating and formatting, 5-24
Abend-AID report shared directories
allocating and formatting, 5-24
accept base code
to distribution libraries, B-21
accept base code to distribution libraries, 3-15, 3-30,
Acrobat PDF online documentation, xvi
allocating
Abend-AID for CICS transaction shared directories,
Abend-AID report shared directories and databases,
dynamically allocating libraries, 5-15
global CSI and SMP/E datasets, B-19 libraries and SMP/E datasets, B-19
libraries at TSO startup, 5-17
source listing files, 5-25 source listing shared directories and databases, 5-25
allocating libraries and SMP/E datasets, 3-13, 3-28,
APF authorization
apply
base code to target libraries, B-20
maintenance during installation, B-22
apply base code to target libraries, 3-14, 3-29, 3-43
Assembler Language Processor
modify JCL for installation, 5-31
postprocessor, 5-32 postprocessor DD statement, 5-32
specifying jobcard information, B-8
automated compiler options, 2-7
base code
accept to distribution libraries, 3-15, 3-30, 3-44,
apply to target libraries, 3-14, 3-29, 3-43, B-20
batch file utility
BookManager softcopy documentation, xvi
C
C Language Processor
CD
modify JCL for installation, 5-32
capturing suppressed source code, preprocessor, 2-7
changes
CMF (Customer Modification Facility), 2-6
COBOL Language Processor
modify JCL for installation, 5-27
postprocessor, 5-28 postprocessor compiler JCL, 5-28
SLCXCNTL installation library members, 5-29–5-30
common components
compile errors, handling
Compuware
Frontline web site, xviii phone number and address, xviii
Compuware GLOBAL CSI Dataset field, A-6
Compuware Shared Services
Compuware/VF
allocating libraries at TSO startup, 5-17
dynamically allocating libraries, 5-15 installing, 5-15
linking tutorials to main tutorial panel, 5-19
confirm JCL processing screen, B-16
confirming installation selections screen, B-4
I-2
Enterprise Common Components Installation and Customization Guide
Contact Information feature, installing, 5-20
creating
Abend-AID for CICS databases, 5-26
Abend-AID for CICS shared directories, 5-26
source listing databases, 5-25 source listing shared directories, 5-25
CSI for Compuware products, A-6
CSS
common files and utilities, 1-3 components, 1-3
Customer Modification Facility, 2-6
installation library members, 2-10
sharing DDIO files with multiple CPUs, 2-6
SLCXCNTL sample library tutorials, 5-19
SLCXMENU message library, 5-18
target and distribution zones, B-9
allocating libraries at TSO startup, 5-17
dynamically allocating libraries, 5-15 installing, 5-15
linking tutorials to main tutorial panel, 5-19
Customer Modification Facility, 2-6
customer number, more than one, 6-2
customer support web site, xvi
customized translation table, G-2
CWPPRMO command
D
DD statements
C Language Processor postprocessor, 5-33
DDIO files
debugging production programs, 2-9
sharing with multiple CPUs, 2-6
testing and debugging programs, 2-9 writing listings to, 2-9
debugging
Distributed Viewing Support
distribution zones, 3-9, 3-24, 3-38
DVS
dynamically allocated files, 2-8
E
ECC
component prefixes and FMIDs, 2-4
installation considerations, 2-5
installation, overview of, 2-1
JCL Customization Facility, B-2
Enterprise Common Components, G-3 entry, G-3
environment
executing
Extended Play (EP) products, A-2, A-11
I-3
F
host system
transferring a License Certificate, 6-1, 6-4
Figure 1-12 on page 1-12, 3-26
file formats
File-AID for DB2 users
File-AID for IMS users
File-AID link from Compuware/VF
File-AID/MVS users
formatting
Abend-AID for CICS transaction shared directories,
Abend-AID report shared directories and databases,
source listing files, 5-25 source listing shared directories, 5-25
FrontLine support web site, xvi
FTP transfer of installation files, A-5
G
global CSI dataset name, specifying, 3-7, 3-21, 3-36,
H
HCI
installation considerations, 2-16
target and distribution zones, B-14
help
high-level qualifiers
HLQ
for distribution zone datasets, A-7 for target zone datasets, A-7
HOLDDATA, reviewing, 3-14, 3-29, 3-43
horizontal translation table
Host Communications Interface, G-3
J
I
import license certificate, 6-12
initializing
target and distribution zone CSIs, B-19
initializing target and distribution zone CSIs, 3-14,
installation
Contact Information feature, 5-20
DASD unit name, 3-6, 3-20, 3-34
ECC installation overview, 2-1
File-AID access from Compuware/VF, 5-21
global SMP/E dataset high-level qualifier, 3-6, 3-20,
installation cautions, ECC, A-1, B-1
installing and enabling LMS, 6-4
JCL Customization Facility, 3-4, 3-18, 3-33, B-2
job card information, 3-8, 3-23, 3-37, B-8
selecting components, 3-4, 3-18, 3-33, B-2
SMP/E work unit, 3-6, 3-20, 3-34
SMS data class, 3-7, 3-21, 3-35, B-6
SMS management class, 3-7, 3-21, 3-35, B-6 specify global CSI dataset name, 3-7, 3-21, 3-36, B-6
specify SMS parameters, 3-6, 3-21, 3-35, B-5
specifying environment information, 3-5, 3-19,
storage class, 3-7, 3-21, 3-35, B-6
translation tables, customized, 5-3
Installation JCL Customization Facility, G-3
installation jobs
installing third-party products, A-12
installing Windows products, A-11
Internet, Compuware WWW address, xvi
ISPF dialogs, activating, 5-15
Japanese language support, 3-10, 3-24, 3-39, B-10
JCL
I-4
Enterprise Common Components Installation and Customization Guide
Unload SMP/E Installation Sample Library, B-2
JCL Customization Facility
JCL Customization Facility, using, 3-4, 3-18, 3-33
JCL processing, 3-11, 3-25, 3-40
job card
information screen, Assembler, B-8 specifying information, B-8
job card, specifying information, 3-8, 3-22, 3-36
L
label, installation media, A-2
preparing LAU screen, 6-5 set up, 6-5
License Administration Utility
creating, 6-7 selection screen, 6-7, 6-9
License Management System, G-3
license verification report, 6-16
LMS
establishing runtime environment, 2-15 execution sequence, 2-15 functions, 2-15
importing a license certificate, 6-1
information gathering, 1-7 installation, 1-7
installation considerations, 2-15
installation steps (table), 6-2
license verification report, 6-16
more than one customer number, 6-2
operating environment, 1-6 overview, 1-6
preliminary considerations, 6-1
running more than one LMS, 6-1 runtime environment, 6-1
target and distribution zones, B-13
transferring a License Certificate to host system, 6-1
validating product access requests, 2-16
LMSINIT
prepare an APF authorize LMSINIT, 6-14
M
mainframe FTP information, A-5
maintenance
modify global SMP/E detail values, B-7
N
O
overview
I-5
P
PL/I Language Processor
modify JCL for installation, 5-29
Assembler Language Processor, 5-32
Assembler Language Processor DD statement, 5-32
COBOL Language Processor, 5-28
COBOL Language Processor compiler JCL, 5-28
Assembler Language Processor, 5-31
automated compiler options, 2-7 benefits, 2-7
capturing suppressed source code, 2-7
COBOL Language Processor, 5-27
dynamically allocated files, 2-8
simplified JCL, 2-7 steps, 2-7
Problem Documentation Utility, G-4
R
Receive From Network installation
receiving
report databases
report files
report member detailing JCL processing screen, B-17
report shared directory
restricted zaps
Customer Modification Facility, 2-6
revisions, changes in each, xiii
runtime environment
S
selecting components to install screen, B-3, C-2–C-4
sequential source listing database
SLCXCNTL
COBOL Language Processor, 5-29–5-30
CXCIREG sample library member, 5-20
CXCIVSAM sample library member, 5-20
installation library members, 5-3, 5-30
sample library tutorials, 5-19
SLCXCNTL installation library members, 5-3
SLCXLOAD load library, 5-4, 5-18
SLCXMENU message library, 5-18
allocating global datasets, B-19
allocating libraries and datasets, 3-13, 3-28, 3-42,
allocating zones, 2-3 caution, 2-3
installation and maintenance, 2-3
JCL Customization Facility, description of, 2-4
SMP/E high-level qualifiers, 3-9, 3-23, 3-37
SMP/E installation
firewall settings, A-2 from a PC, A-2 system requirements and preparation, A-2
SMS
data class, 3-7, 3-21, 3-35, B-6 management class, 3-7, 3-21, 3-35, B-6
specifying parameters screen, B-6
source listing, G-4 source listing database, G-4
source listing databases
source listing files
allocating and formatting, 5-25
source listing shared directories
allocating and formatting, 5-25 creating, 5-25
specifying jobcard information, 3-8, 3-22, 3-36
storage class, 3-7, 3-21, 3-35, B-6
system environment
system nodes
I-6
Enterprise Common Components Installation and Customization Guide
T
testing and debugging programs, 2-9
third-party installation files, A-12
transfer license certificate to host, 6-4
translation tables, installing custom, 5-3
TSO logon PROCs
tutorials
U
unload ECC installation sample library, B-2
uploading installation files, A-2 uploading maintenance files, A-2
V
validating LMS product access requests, 2-16
verification report (LMVERIFY), G-4
verify installation information, 3-11, 3-25, 3-40, B-16
verifying global CSI dataset name screen, B-6
vertical translation table
Viewing Facility
VSAM Source Listing Database
W
Windows installation files, A-11
World Wide Web, Compuware address, xvi
X
Xpediter/CICS
Xpediter/TSO
Download
Advertisement
Key features
Provides a common infrastructure for Compuware products
Includes Compuware Shared Services, License Management System, and Host Communications Interface
Supports various MVS operating systems
Offers customization options to tailor ECC to your environment
Provides detailed installation instructions and customization steps
Frequently asked questions
Enterprise Common Components (ECC) is a set of software components that provide a common infrastructure for Compuware products. ECC includes Compuware Shared Services (CSS), the License Management System (LMS), and the Host Communications Interface (HCI).
ECC provides a common infrastructure for Compuware products, supports various MVS operating systems, and allows for customization to tailor the components to your environment.
This document provides detailed instructions on installing and customizing ECC. It includes information on required components, procedures, and specific customization steps for each component.