Contents
Requirements for Connection between the NEC ESMPRO Manager Server and Managed Server 16
NEC ESMPRO Manager Server Managed Server...................................................... 19
About the coexistence of NEC ESMPRO Manager with DianaScope Agent or NEC
About shutdown OS during DC-OFF state by scheduled running....................................... 37
2
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
3
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
Trademarks
NEC ESMPRO and NEC EXPRESSBUILDER are trademarks of NEC Corporation.
Microsoft, Windows, Windows Vista, Windows Server, Windows NT, and MS-DOS are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries.
Intel and Pentium are registered trademarks of Intel Corporation.
Datalight is a registered trademark of Datalight, Inc.
ROM-DOS is a trademark of Datalight, Inc.
LSI-Logic, MegaRAID, and Power Console Plus are registered trademarks or trademarks of LSI Logic Corp.
Novell and NetWare are registered trademarks of Novell, Inc. of the United States.
AT is a registered trademark of International Business Machines Corporation in the United States and other countries.
Adaptec and its logo is a registered trademark of Adaptec, Inc. of United States.
SCSISelect is a trademark of Adaptec, Inc. of the United States.
Adobe, Adobe logo, and Acrobat are trademarks of Adobe Systems Incorporated.
DLT and DLTtape are trademarks of Quantum Corporation of the United States.
All other product, brand, or trade names used in this publication are the trademarks or registered trademarks of their respective trademark owners.
Windows 2008 stands for Microsoft® Windows Server™
2008 Standard Edition operating system and
Microsoft® Windows Server™
2008 Enterprise Edition operating system. Windows Vista stands for
Microsoft® Windows Vista® Business operating system. Windows Server 2003 x64 Editions stands for
Microsoft® Windows® Server™ 2003 R2, Standard x64 Edition Operating system and Microsoft®
Windows® Server™ 2003 R2, Enterprise x64 Edition operating system, or Microsoft® Windows® Server™
2003, Standard x64 Edition operating system and Microsoft® Windows® Server™ 2003, Enterprise x64
Edition operating system. Windows 2003 stands for Microsoft® Windows Server™
2003 operating system and Microsoft® Windows Server™
2003 Standard Edition and Enterprise Edition. Windows XP x64 Edition stands for Microsoft® Windows® XP Professional x64 Edition operating system. Windows XP stands for
Microsoft® Windows® XP Professional operating system and Microsoft® Windows® XP Home Edition operating system. Windows 2000 stands for Microsoft® Windows® 2000 Server operating system and
Microsoft® Windows® 2000 Advanced Server operating system, and Microsoft® Windows® 2000
Professional operating system. Windows Me stands for Microsoft® Windows® Millennium Edition operating system. Windows 98 stands for Microsoft® Windows® 98 operating system. Windows 95 stands for Microsoft® Windows® 95 operating system. DOS stands for MS-DOS® or ROM-DOS®.
NEC ESMPRO Manager includes JRE (Java Runtime Environment) distributed free of charge by Sun
Microsystems, Inc. , Tomcat distributed free of charge by Apache Software Foundation, and the VNC distributed free of charge by AT&T laboratories Cambridge. The end user license agreement is necessary for using these products. For details on their copyright and ownership, see the LICENSE files below.
Tomcat: LICENSE under the /opt/nec/es_manager/wbserver /wbserver
JRE: LICENSE under the /opt/nec/es_manager/wbserver /jre
NEC ESMPRO Manager uses DWR distributed free of charge by Getahead and prototype.js distributed free of charge by Prototype, sortable.js distributed free of charge by Stuart Langridge. For details on their copyright and ownership, see the LICENSE files below.
DWR (dwr.jar): ApacheLicense_v2.txt under the /opt/nec/es_manager/wbserver /wbserver. prototype.js: prototypejs_LICENSE.txt under the /opt/nec/es_manager/wbserver /wbserver. sortable.js: sortablejs_licence.htm under the /opt/nec/es_manager/wbserver /wbserver.
4
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
Notes
(1) No part of this document may be reproduced in any form without the prior written permission of NEC
Corporation.
(2) The contents of this document may be revised without prior notice.
(3) The contents of this document shall not be copied or altered without the prior written permission of NEC
Corporation.
(4) All efforts have been made to ensure the accuracy of all information in this document. If you notice any part unclear, incorrect, or omitted in the document, contact your authorized NEC sales representative.
(5) NEC assumes no liability for damages arising from the use of this product, nor any liability for incidental or consequential damages arising from the use of this document regardless of (4).
5
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
About This Document
This document introduces remote management using the server management utility “NEC ESMPRO
Manager” for Linux and explains the complete procedures from installation to managed server’s setup.
Before attempting to operate the server management utility NEC ESMPRO Manager, read this document so as to gain an adequate understanding of the contents.
Notes
This document is intended for persons who are familiar with the operating system’s functions and operations and the network’s functions and setup. For operations and inquiries about the operating system, see its online help information.
This document covers universal information about generally managed servers. The notes and restrictions on use of each product as a managed server are explained in the user’s guide provided with the managed server and “Appendix C. Managed Servers Summary” on the “NEC ESMPRO Manager Ver.5”.
If the NEC EXPRESSBUILDER(SE) CD-ROM or Maintenance Management Tool CD-ROM is attached to the managed server, read the word in place of “NEC EXPRESSBUILDER” in this document.
Names used with screen images in this document are fictitious. They are unrelated to existing product names, names of organizations, or individual names. The setting values on the screen images are shown as examples, so setting values such as IP addresses on screen images are not guaranteed for operation.
In this document , “¥” expresses back slash.
About Symbols in This Document
The following explains three symbols that are used in this document:
IMPORTANT:
Points or particular notes you must follow when handling software of servers.
CHECK:
Points or notes you need to check when handling software or servers.
TIPS:
Useful information.
Other Documents for NEC ESMPRO Manager
For other information about the NEC ESMPRO Manager, see the documents below.
Which servers can NEC ESMPRO Manager control?
See the “Appendix C. Managed Servers Summary” of the “NEC ESMPRO Manager Ver.5 Setup
Guide”.
How to operate after setup.
See the NEC ESMPRO Manager’s online help information.
How to operate the command line Interface.
See the “NEC ESMPRO Manager Command Line Interface”.
6
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
About Download of the Latest NEC ESMPRO Manager
See the following URL for NEC ESMPRO Manager information. You can download the latest version of the
NEC ESMPRO Manager from the URL. http://www.nec.co.jp/smsa/
7
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
Chapter1 About NEC ESMPRO Manager
NEC ESMPRO Manager is software designed for reducing operational management costs by remotely managing servers.
The ESMPRO Manager is primarily made up of “NEC ESMPRO Manager” running on a management PC
(called a “ESMPRO Manager server”) and “NEC ESMPRO Agent Extension” running on a managed server.
Remotely manageable servers with ESMPRO Manager are the servers that conform to IPMI (Intelligent
Platform Management Interface) Ver.1.5 or Ver.2.0 as the industry standard for server management.
The ESMPRO Manager provides the following capabilities:
Rebuilding even if the operating system on the managed server has failed.
Even if the operating system on the managed server is inoperable (in the state of operating system’s stall, BIOS POST (Power On Self Test), or DC OFF), ESMPRO Manager allows you to collect the managed server’s hardware information and control the power supply.
Operation while viewing the managed server’s screen.
While key-in and mouse operations are enabled, the managed server’s screen can be viewed on the remote browser at any time during POST just after the managed server is turned ON.
Operation of more than one managed server at a time.
By specifying a server group, you can provide power control or change a setting for managed servers through a single operation.
Specification of remote operation time
The managed server can be turned OFF or information can be collected at pre-specified time, so
ESMPRO Manager is available for nighttime batch processing.
Easy operation through the Internet.
The managed server can be operated with a Web browser. If you use Internet’s standard SSL (Secure
Socket Layer) for the ESMPRO Manager, you enable secure remote operation from an external network.
8
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
1.1 Components
The NEC ESMPRO Manager consists of the following software group:
Software running on the NEC ESMPRO Manager server
NEC ESMPRO Manager Manages a remote server by communicating with the BMC (Baseboard
Management Controller), System BIOS, and DianaScope Agent or NEC ESMPRO Agent
Extension that are on the managed server.
Software running on the managed server
NEC ESMPRO Agent Extension
Configures the BMC on the managed server, and executes commands specified by the NEC
ESMPRO Manager.
TIPS:
BMC is provided with form below. For details, see “Appendix C. Managed Servers
Summary” of the “NEC ESMPRO Manager Ver.5 Setup Guide”.
- Managed server integrates BMC.
- Managed server integrates EXPRESSSCOPE Engine or EXPRESSSCOPE Engine 2.
- Remote Management Card integrates BMC.
- Advanced Remote Management Card integrates BMC.
EXPRESSSCOPE Engine and EXPRESSSCOPE Engine 2 are generically called
EXPRESSSCOPE Engine series.
1.2 Connection Types
There are only via LAN of connections that can be made between the NEC ESMPRO Manager server and managed server.
9
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
1.3 Functions
The NEC ESMPRO Manager has following functions:
Remote console
The remote console function allows the operator to view the managed server’s display screen from the remote console.
During POST (Power On Self Test) just after the power is turned ON, or while DOS is active, data can be input into the managed server from the keyboard. The managed server’s BIOS setup and POST monitoring can be enabled remotely by this function.
Even after Linux has been booted, the operator can perform various operations such as OS setting change or application execution while viewing the managed server’s screen on the remote browser.
Information collection
The information collection function allows the operator to collect information from the managed server.
Server Status: Managed server’s STATUS lamp state and power state.
Version Information: Information about the versions of DianaScope Agent or NEC ESMPRO Agent
Extension, operating system,
LAN driver, and System BIOS
BMC Configuration: BMC configuration information. You can also change the information.
Power Restore Delay: Interval from AC-ON to DC-ON that is also set using BIOS Setup utility on
the managed server.
IPMI Information: Hardware information, log information, and the current status of each sensor.
Power Management: Managed server’s power value. You can read it for spcified period.
Power control
The following power control is provided for the managed server:
Power ON
Power OFF
Power Cycle (turns power on after turning it off.)
Reset
DUMP Switch (The managed server performs the same operation as when the dump switch is pressed.)
Sutdown OS
Server Monitoring
The server monitoring function always monitors the managed server’s STATUS lamp state and power state. When a failure occurs, the function notifies the operator of the failure.
If the managed server is a CPU blade, this function also monitors and notifies the operator of the slot change.
The server monitoring function is supported only via LAN.
10
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
Remote batch
The remote batch function enables the following control automatically at specified time:
Power ON
Power OFF
Shutdown OS
Clear System Event Log
Collect System Event Log, Sensor Information, Filed Replaceable Unit Information
Scheduled running
The scheduled running function enables the setting of a down period for the managed server. According to the specified schedule, the managed server shuts down the operating system at the start of the down period and turns the power ON at the end.
Operation through the command line
In general, NEC ESMPRO Manager is operated on the Web browser. The command line interface also provides commands like power control or information collection.
TIPS:
For details of the command line interface, see “NEC ESMPRO Manager Command Line
Interface”.
11
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
1.3.1 NEC ESMPRO Agent Extension Function
Before the following of the functions introduced in 1.3”Functions” can be used, NEC ESMPRO Agent
Extension must be installed in the managed server.
Remote console
NEC ESMPRO Agent Extension is required for remote console function that displays the graphic screen after Linux has been booted on the managed server. The remote console screen data is encrypted by the
NEC ESMPRO Agent Extension, and then securely sent to the NEC ESMPRO Manager.
Shutdown OS
The NEC ESMPRO Agent Extension shuts down the operating system upon request of the NEC
ESMPRO Manager .
Version Information collection
Information about the versions of the operating system, LAN driver, and BIOS in addition to the NEC
ESMPRO Agent Extension can be collected upon request of the NEC ESMPRO Manager.
BMC configuration information collection/change
The BMC configuration information set on the managed server can be collected or changed upon request of the NEC ESMPRO Manager.
Scheduled Running
According to the specified schedule sent by the NEC ESMPRO Manager, the NEC ESMPRO Agent
Extension shuts down the operating system at the start of the down period. It also makes a setting for the
BMC to turn the power OFF at the end of the down period.
TIPS:
NEC ESMPRO Agent Extension will perform the scheduled running after the NEC
ESMPRO Manager set the schedule in the NEC ESMPRO Agent Extension.
12
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
Chapter2 System Requirements
2.1 NEC ESMPRO Manager server
Install NEC ESMPRO Manager in a management PC.
The management PC installed the NEC ESMPRO Manager is called a “NEC ESMPRO Manager server.”
Hardware
Processor
Intel Celeron 566MHz or more, , or equivalent compatible processor
(Recommended Intel Pentium III 1GHz or more)
Memory
128MB or more. (Recommended 256MB or more)
Availability of hard disk
256MB or more
Communication Medium
TCP/IP network
Software
Operating System
Red Hat Enterprise Linux ES 2.1
Red Hat Enterprise Linux AS 2.1
Red Hat Enterprise Linux ES 3.0 (x86, Intel EM64T)
Red Hat Enterprise Linux AS 3.0 (x86, Intel EM64T)
Red Hat Enterprise Linux ES 4 (x86, IntelEM64T)
Red Hat Enterprise Linux AS 4 (x86, intelEM64T)
Red Hat Enterprise Linux 5 (x86, intelEM64T)
Red Hat Enterprise Linux 5 AP (x86, intelEM64T)
Miracle Linux Standard Edition 2.1
Miracle Linux 3.0 – Asianux Inside
Miracle Linux 4.0 – Asianux Inside (32bit, 64bit)
Number of managed servers
Addition of server licenses permits a single NEC ESMPRO Manager to manage a maximum of 512 servers.
13
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
2.2 Web client
The NEC ESMPRO Manager is operable on Web clients connected to the NEC ESMPRO Manager server via
LAN that satisfy the following conditions:
The NEC ESMPRO Manager server can also be used as a Web client.
Web browser
Internet Explorer 6.0 and above
FireFox 2.0 and above
CHECK:
If you use NEC ESMPRO Manager from a browser, install JRE 1.4.2 and above on the browsing PC. If JRE is not installed, some screen is not displayed correctly.
Java Applet and Java scripts must be executable.
1024 by 768 pixels or more are recommended as a screen area in display properties.
14
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
2.3 Managed server
This section explains conditions for servers to be managed by the NEC ESMPRO Manager.
Hardware
-- The server that integrates a standard BMC conforming to IPMI Ver.1.5 or Ver.2.0.
-- The server that integrates EXPRESSSCOPE Engine or EXPRESSSCOPE Engine 2 conforming to
IPMI Ver.2.0.
-- The server that is installed a Remote Management Card [N8115-01CP01] conforming to IPMI
Ver.1.5 or Ver.2.0.
-- The server that is installed an Advanced Remote Management Card [N8115-02CP01] conforming to
IPMI Ver.2.0.
CHECK:
The monitor function by the SNMP does not support it. NEC ESMPRO Manager will not be managed as the result of the install. See the “Appendix C. Managed Servers Summary” of the “NEC ESMPRO Manager Ver.5 Setup Guide”.
The required environment varies depending on the connection type with the managed
TIPS:
EXPRESSSCOPE Engine and EXPRESSSCOPE Engine 2 are generically called
EXPRESSSCOPE Engine series.
Software
-- You cannot use the monitoring function by the SNMP even if you install NEC ESMPRO Agent.
15
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
2.4 Requirements for Connection between the NEC ESMPRO
Manager Server and Managed Server
LAN connection
TCP/IP network
LAN port
-- LAN port that BMC uses depends on the type of BMC. Some BMC uses standard LAN port. Other
BMC uses an exclusive LAN port (Management LAN Port). See the “Appendix C. Managed Servers
Summary” of the “NEC ESMPRO Manager Ver.5 Setup Guide”.
-- There are 2 types of managed servers that BMC uses standard LAN port: one type is permitted to use only LAN1 port, and the other type is permitted to use both LAN1 and LAN2 ports. See the
“Appendix C. Managed Servers Summary” of the “NEC ESMPRO Manager Ver.5 Setup Guide”.
16
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
2.4.1 Notes on Managed Servers and Network Devices
This section explains particular notes on managed servers and network devices.
-- Use of network switch / router
If the managed server installed BMC that uses a standard LAN port or loaded Advanced Remote
Management Card, and there is network switch / router between manager server and the managed servers, please set the network switch / router to receive Gratuitous ARP.
See each instruction manual of the switch / router about how to set it.
-- Use of a layer-2/layer-3 switching hub
Set “Disable” for the STP (Spanning Tree Protocol) function of the switching hub or the STP of the port to which a managed server is connected.
Set “Enable” for the auto-negotiation function of the port to which a managed server is connected.
-- Use of DHCP
In case that BMC on the managed server uses a standard LAN port, communication between the NEC
ESMPRO Manager and System BIOS or BMC is not compatible with a DHCP environment.
Be sure to use a fixed IP address with the NEC ESMPRO Manager server in which the NEC ESMPRO
Manager is to be installed.
To use a managed server in a DHCP environment, start the DianaScope Agent or NEC ESMPRO Agent
Extension.
-- Setting of Teaming for standard LAN with the OS (providing redundancy or multiplexing with multiple network adapters) for the managed server installed BMC that uses a standard LAN port:
The managed server installed BMC that uses a standard LAN port shares the embedded standard LAN controller between BMC, System BIOS and OS, but the BMC and System BIOS do not support the LAN teaming modes including AFT (Adapter Fault Tolerance) and ALB (Adaptive Load Balancing). So if the
AFT mode or ALB mode was made available by OS, NEC ESMPRO Manager can communicate with
BMC and System BIOS only under the following conditions while Failover does not occur.
- If RLB (Receive Load Balancing) is set with ALB (Adaptive Load Balancing), disable the RLB. (If RLB
cannot be disabled, NEC ESMPRO Manager cannot communicate with BMC.)
- Make the Teaming-set address (“preferred primary”) identical to the LAN1 IP address and MAC address
in the BMC configuration information.
- Even if the configuration of LAN2 for the BMC on the managed server is available, do not set LAN2 in
the BMC configuration information.
- Even if the configuration of LAN2 for the BMC on the managed server is available, do not set LAN2 in
the BMC configuration information.
- If the teaming is set with channel bonding on Linux, please add “mode” and “primary” definition to the
line of /etc/modprobe.conf or /etc/modules.conf as following. options bondname mode=1 primary=eth0 miimon=100
-- Setting of Teaming for LAN with the OS (providing redundancy or multiplexing with multiple network adapters) for the managed server installed BMC that uses an exclusive LAN port (Management LAN port):
If the teaming setting was made available for the LAN port that DianaScope Agent or NEC ESMPRO
Agent Extension uses, see “Appendix C. Managed Servers Summary” of the “NEC ESMPRO Manager
Ver.5 Setup Guide”.
17
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
-- Change of the hardware of a default gateway or an alert receiver
In case that there is a gateway between NEC ESMPRO Manager server and a managed server, re-configure
BMC on the managed server after the change the hardware of the gateway. In case that there is not gateway between an alert receiver and a managed server, re-configure BMC on the managed server after the change the hardware of the alert receiver. The BMC on the managed server can know MAC address of the new hardware by setting the BMC configuration.
-- Use of a dialup router or a PPP server
If an alert receiver via modem uses Windows Remote Access Service, please select “Allow any authentication including clear text” about the encryption on the Windows Remote Access Service properties.
-- Restrictions on use of the standard serial port 2 (COM2)
The standard serial port 2 (COM2) on a managed server cannot be used for connecting another device in the following cases because the BMC occupies the serial port 2:
- The managed server compatible with SOL and set enable on following BMC Configuration items:
“Remote control (WAN/Direct)”
“Redirection (LAN)”
“Redirection (WAN/Direct)”
- Connection via modem or Direct connection has been made.
- Direct connection has been set in the BMC configuration information. (Even if the NEC ESMPRO
Manager and managed server are not connected, the BMC occupies the serial port 2 (COM2).)
CHECK:
See “Appendix C. Managed Servers Summary” of the “NEC ESMPRO Manager Ver.5
Setup Guide” to confirm whether that your server supports SOL.
18
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
2.5 Port numbers that NEC ESMPRO Manager uses
NEC ESMPRO Manager uses the following port numbers:
2.5.1 Web Client
NEC ESMPRO Manager Server
Function Web Client Protocol NEC ESMPRO Manager Server
Module Name Port No.
/direction
Port No. Module Name
Management
/ monitoring
Web Browser Unknown TCP
←→
8080
(*1)
NEC ESMPRO Manager
*1 The port number used by Tomcat can be changed on setting of NEC ESMPRO Manager.
2.5.2 NEC ESMPRO Manager Server
Managed Server
Function
Operation with
Command Line I/F
Alert from BMC
Web Client
Module Name
NEC ESMPRO Manager
NEC ESMPRO Manager
Port No.
47117
(*2)
162
Protocol
UDP
←→
UDP
←
NEC ESMPRO Manager Server
/direction Port No.
Remote Console
(CUI, non-SOL)
Remote Console
(CUI, SOL)
Remote Console
(GUI,
GUI Remote Console
Setting Enabled)
Remote Console
(GUI,
GUI Remote Console
Setting Disabled)
Power Control
NEC ESMPRO Manager
NEC ESMPRO Manager
NEC ESMPRO Manager
47115
47117
(*2)
NEC ESMPRO Manager Unknown
(*3)
Unknown
(*3)
TCP
←→
Server Monitoring
NEC ESMPRO Manager 47117
(*2)
NEC ESMPRO Manager 47117
(*2)
UDP
←→
UDP
←→
Information Collection NEC ESMPRO Manager Unknown
(through NEC
ESMPRO Agent
(*3)
Extension or
DianaScope Agent)
TCP
←→
Information Collection UDP
(through BMC) (*2) ←→
Remote Batch
Scheduled Running
NEC ESMPRO Manager 47117
(*2)
NEC ESMPRO Manager Unknown
(*3)
UDP
←→
TCP
←→
UDP
←→
UDP
←→
TCP
←→
623 BMC
47130-
47139
(*4)
5900-
5901
623 BMC
47120-
47129
(*4)
Module Name
NEC ESMPRO Agent
Extension,
DianaScope Agent
GUI Remote
Console Function
623 BMC
NEC ESMPRO Agent
Extension,
DianaScope Agent
623 BMC
623 BMC
47120-
47129
(*4)
NEC ESMPRO Agent
Extension,
DianaScope Agent
623 BMC
623 BMC
*2 The NEC ESMPRO Manager port number used for communication with the BMC can be changed on the “Environment” screen.
*3 “Unknown” means that the module uses one port that any module does not use.
*4 The module uses one port of the range.
19
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
2.5.3 NEC ESMPRO Manager Server
EM Card
Function Web Client
Module Name Port No.
Protocol NEC ESMPRO Manager Server
/direction
Port No. Module Name
Information Collection
Server Monitoring
BMC configuration of
CPU blade
Operation with
Command Line I/F
NEC ESMPRO Manager 47117
(*2)
NEC ESMPRO Manager 47170-
47179
(*4)
NEC ESMPRO Manager 47180-
47189
(*4)
NEC ESMPRO Manager 47117
(*2)
NEC ESMPRO Manager 47117
(*2)
NEC ESMPRO Manager 47117
(*2)
UDP
←→
TCP/IP
←→
UDP
←→
UDP
←→
UDP
←→
UDP
←→
*2 The NEC ESMPRO Manager uses a same port number for communication with BMC and EM card.
The port number can be changed on the “Environment” screen.
*4 The module uses one port of the range.
2.5.4 NEC ESMPRO Manager Server Inside
Function Web Client Protocol NEC ESMPRO Manager Server
Module Name Port No.
NEC ESMPRO Manager NEC ESMPRO Manager 1099
*4 The module uses one port of the range.
/direction
Port No.
UDP
←→
1099
Module Name
NEC ESMPRO Manager
20
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
Chapter3 NEC ESMPRO Manager Installation
3.1 NEC ESMPRO Manager Installation for Linux
3.1.1 Check before installation
Check the followings:
-- See chapter 2.1 to check the system requirement of NEC ESMPRO Manager server.
-- Login to Linux as root user, or get authority of root by “su” command.
CHECK:
NEC ESMPRO Manager use the port number 8080. When Tomcat using port 8080 for is installed, please stop Tomcat before installing NEC ESMPRO Manager.
After installation of NEC ESMPRO Manager, you can change a port number to use.
3.1.2 Install the NEC ESMPRO Manager
Install the NEC ESMPRO Manager.
In below input examples, the installer file name is shown like “esmpro-N.NN.sh”. “N.NN.NN” means the version.
(1) Copy the NEC ESMPRO Manager installer into any directory.
(2) Move to the directory containing the NEC ESMPRO Manager installer.
The following is an example of installation into /usr/local/bin: cd /usr/local/bin
(3) Start the NEC ESMPRO Manager installer.
The NEC ESMPRO Manager will be installed under /opt/nec/es_manager.
./esmpro-N.NN.sh
(4) The terms of the end user license agreement for the product will be displayed. Carefully read the terms, and if you agree to the terms, input “yes” and “Enter” key.
CHECK:
When the NEC ESMPRO Manager has already been installed, a message to confirm whether you continue the installation is displayed. If you continue the installation, input
“add“ and “Enter” key. If you quit the installation, input “exit “and “Enter” key.
21
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
(5) A message to register an administrator of NEC ESMPRO Manager. Enter the administrator name and password.
(6) A message to confirm whether you specify web clients to login to the NEC ESMPRO Manager is displayed. If you specify them, input “yes “ and “Enter” key. And then input IP address range in which login to the NEC ESMPRO Manager is permitted.
TIPS:
You can also set this item after finishing the installation. If this item is not set, NEC
ESMPRO Manager permits login from a web browser on the NEC ESMPRO Manager server.
When the installation is completed, the following message is displayed:
“Installation of NEC ESMPRO Manager is now completed.”
22
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
3.1.3 Update install the NEC ESMPRO Manager
Install the NEC ESMPRO Manager.
In below input examples, the installer file name is shown like “esmpro-N.NN.sh”. “N.NN.NN” means the version.
(1) Copy the NEC ESMPRO Manager installer into any directory.
(2) Move to the directory containing the NEC ESMPRO Manager installer.
The following is an example of installation into /usr/local/bin: cd /usr/local/bin
(3) Start the NEC ESMPRO Manager installer.
./esmpro-N.NN.sh
(4) A message to confirm whether you continue the installation is displayed. Input “add“ and “Enter” key.
When the update installation is completed, the following message is displayed:
“Installation of NEC ESMPRO Manager is now completed.”
23
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
3.2 DianaScope Manager Un-installation for Linux
3.2.1 Uninstall the DianaScope Manager
In below input examples, the installer file name is shown like “esmpro-N.NN.NN.sh”. “N.NN.NN” means the version.
(1) Start the NEC ESMPRO Manager installer.
./esmpro-N.NN.NN.sh
(2) The terms of the end user license agreement for the product will be displayed. Input “yes” and “Enter” key.
(3) A message to confirm whether you continue the installation is displayed. Input “delete “ and “Enter” key.
When the un-installation is completed, the following message is displayed:
“Uninstallation of NEC ESMPRO Manager is now completed.”
24
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
3.3 Login
After installation of the NEC ESMPRO Manager is completed, confirm that you can log into the NEC
ESMPRO Manager.
(1) Make access to the following address using the Web browser on the Web client.
URL: http:// “the computer name installed the NEC ESMPRO Manager” : ”port number that the
Tomcat uses” /esmpro/
An Example of address to access from the web browser on the NEC ESMPRO Manager server is shown.
”http://localhost:8080/esmpro/”
(2) The login screen of the NEC ESMPRO Manager will be open.
Input the administrator name and the password that has registered at the installation, and then click
“login”.
25
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
When the login is successful, the following screen will appear:
CHECK:
“Tools”, “Search”, “Environment Setting” and other commands are displayed in the bar.
This bar is called “Header menu”.
3.4 Setting Environment
You can change the optional setting of the NEC ESMPRO Manager. Click “Environment Setting” on the
“Header menu” to check the setting. For details, see the online help.
26
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
3.5 Change of the port number
After installation of NEC ESMPRO Manager, you can change a port number to use.
(1) Stop the NEC ESMPRO Manager.
/etc/rc.d/init.d/esmsm stop
/etc/rc.d/init.d/esmweb stop
(2) Edit the “server.xml” file to change a port number. The “server.xml” is in the directory containing the
“conf” directory of the installation directory of NEC ESMPSRO Manager.
Move to the “conf” directory that there is a “server.xml” file. cd /opt/nec/es_manager/wbserver/conf
Open the server.xml file with an editor tool, search the description of <Connector> which is specified port number 8080, and change a port number.
<!-- Define a non-SSL HTTP/1.1 Connector on port 8080 -->
<Connector port="8080" maxHttpHeaderSize="8192" maxThreads="150" minSpareThreads="25" maxSpareThreads="75" enableLookups="false" redirectPort="8443" acceptCount="100" connectionTimeout="20000" disableUploadTimeout="true" />
(3) Start the NEC ESMPRO Manager.
/etc/rc.d/init.d/esmsm start
/etc/rc.d/init.d/esmweb start
27
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
3.6 SSL
If you need to login to the NEC ESMPRO Manager using SSL, you should change the setting of the NEC
ESMPRO Manager.
Perform the procedure that is necessary in order to use SSL with the NEC ESMPRO Manager as follows:
(1) Create a key
The Key tool is needed for creating the key using with SSL. The Key tool is contained the NEC
ESMPRO Manager.
Create the key as follows:
/opt/nec/es_manager/jre/bin/keytool -genkey -alias tomcat -keyalg RSA
Some messages are displayed with dialog style. Input the information about the creator of the key.
You need to set the same password as the keystore password to the key password for <sdo>.
The following is shown an example.
Enter keystore password: ******
What is your first and last name?
[Unknown]: Scott Oaks
What is the name of your organizational unit?
[Unknown]: SMCC
What is the name of your organization?
[Unknown]: Sun Microsystems
What is the name of your City or Locality?
[Unknown]: New York
What is the name of your State or Province?
[Unknown]: NY
What is the two-letter country code for this unit?
[Unknown]: US
Is <CN=Scott Oaks, OU=SMCC, O=Sun Microsystems, L=New York, S=NY, C=US> correct?
[no]: yes
Enter key password for <sdo>
(RETURN if same as keystore password): ******
Confirm that the key was created.
~/.keystore
TIPS:
~/ means a home directory for login user.
28
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
(2) Change the setting of the NEC ESMPRO Manager
Edit the server.xml file to enable SLL. The server.xml is in the directory containing the NEC ESMPRO
Manager.
Move to the conf directory that there is a server.xml file. cd /opt/nec/es_manager/wbserver/conf
Open the server.xml file with an editor tool, search the description of <Connector> which is specified port number 8443, and modify the description to a comment form with “<!-” and “->”.
Modify the port number if you need.
Add the keystore file path and the password that is specified at the time creating the keystore, in the description of <Factory>.
<!-- Define a SSL HTTP/1.1 Connector on port 8443 -->
<!-- NOTES: Delete these lines .
<Connector port="8443" NOTES: Change it if you need.
maxHttpHeaderSize="8192"
maxThreads="150" minSpareThreads="25" maxSpareThreads="75"
enableLookups="false" disableUploadTimeout="true"
acceptCount="100" scheme="https" secure="true"
clientAuth="false" sslProtocol="TLS" /> keystoreFile=”< the directory that contains keystore >/.keystore” keystorePass=”< the password >” NOTES:Add these lines.
/>
--> NOTES: Delete thess lines.
(3) Reboot the DianaScope server
Reboot the DianaScope server installed the NEC ESMPRO Manager.
(4) Login
Confirm to login to the NEC ESMPRO Manager with “https:”.
Make access to the following address using the Web browser on the Web client.
URL: https://” the computer name installed the NEC ESMPRO Manager”:” port number that is specified in server.xml”/esmpro/
An Example of address to access from the web browser on the NEC ESMPRO Manager server is shown.
”https://localhost:8443/esmpro/”
29
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
Chapter4 Precautions for Use
4.1 About NEC ESMPRO Manager
4.1.1 About use of two or more NEC ESMPRO Manager
A single managed server can be controlled remotely by up to three NEC ESMPRO Manager servers. Follow these notes on the remote control:
-- Use only one NEC ESMPRO Manager to set/execute the scheduled running function and remote batch function.
-- While one NEC ESMPRO Manager is using the remote console function of a managed server, the other
NEC ESMPRO Managers cannot use the managed server’s remote console function.
-- More than one NEC ESMPRO Manager cannot collect IPMI information from the same managed server concurrently.
-- Use one NEC ESMPRO Manager for managing an EM card. Use one NEC ESMPRO Manager for all EM cards and CPU blades on one blade enclosure.
4.1.2 About Power Control
4.1.2.1 Power OFF, Power Cycle, Reset, and Dump
Since power control is provided by hardware regardless of the state of the managed server’s operating system, the system may be damaged. Be careful of operation under power control.
4.1.2.2 Power OFF, Power Cycle, Reset with the BIOS Setup Utility Active
Do not control the power supply while the BIOS Setup Utility is active on the managed server. Otherwise, the alert setting of BMC configuration will be disabled.
4.1.3 About IPMI Information Collection
While a managed server is tuned OFF, some records of management controller information and FRU (Field
Replaceable Unit) information cannot be read in. Error messages about records which could not be read in are shown in the details display area.
The current status of some sensors cannot be read in either while the managed server is turned OFF.
4.1.4 About Remote Console
4.1.4.1 Restriction on Concurrent Connection to the Remote Console
When a single NEC ESMPRO Manager is operating the remote console of a managed server, another
Manager cannot execute the remote console function for the managed server. A managed server can transmit redirection data to only a single NEC ESMPRO Manager.
4.1.4.2 About Remote Console before OS boot or during DOS program running
If a graphic screen is displayed on a managed server, data cannot be displayed correctly on the CUI remote console. The CUI remote console screen is displayed only when the managed server displays a text screen.
If the DOS program running on a managed server displays Japanese words, follow these notes:
-- On the BIOS Setup Utility screen of the managed server, select “Server”
“Console Redirection” and change Terminal Type” to “PC-ANSI” in advance. (If a managed server of which BIOS Setup does not include the item Terminal Type, Terminal Type is already set to PC-ANSI, so the managed server can be used as it is.)
-- Boot the DOS in English mode (with no Japanese-language driver). At this time, the screen contents cannot be displayed correctly on the managed server, but Japanese words are displayed correctly on the CUI remote console of the NEC ESMPRO Manager.
30
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
4.1.4.3 About Remote Console after starting Linux
Notes in the case of using the remote console after starting Linux on the managed server by the redirection function of Linux are shown below.
-- The Home key and End key are not enabled when you operate Linux with the CUI remote console function.
-- If the managed server is rebooted after NEC ESMPRO Manager displays CUI remote console for the managed server that runs Linux, you may not input following keys on remote console:
F5-F12, Arrows, Insert, Delete, Home, End, Page Up, and Page Down.
Close the remote console window and re-open it.
4.1.4.4 About the display of a special character
The CUI remote console screen is not displayed correctly in the following cases:
-- Terminal Type
If Terminal Type is not set to PC-ANSI on the BIOS Setup Utility screen of a managed server, Japanese words on the POST or DOS screen cannot be displayed correctly on the CUI remote console.
-- Special character
Ruled lines, arrows correctly and en-size left arrows cannot be displayed.
4.1.4.5 In Case of Key-in Failure on the Remote Console
During DOS boot or access to the FD or CD-ROM drive immediately after the managed server’s power switch is turned ON, data cannot be keyed in from the remote console or the keyed data display may be delayed.
4.1.4.6 About power off during GUI remote console
If the managed server is forced a power off by using a power button, reset or pushing DUMP switch during
GUI remote console, the GUI remote console will not be updated. Please reopen the remote console window in this case.
4.1.5 Power Management
The power value which NEC ESMPRO Manager reads from the managed server has about +/-10% margin of error.
4.1.6 About CPU blade auto registration
-- When “Check Connection” of “CPU blade auto registration” was failed.
Retry of “CPU Blade auto registration” is not necessary. You can execute “Check Connection” on “Server
Properties” – “Connection Setting”. If a specified IP address is set from a CPU blade to another CPU blade during “CPU blade auto registration” process (ex. when you replace CPU blade and execute “CPU blade auto registration”), NEC ESMPRO Manager may not be able to connect the CPU blade because old information remains in the ARP table on the management PC. Wait for a few minutes and try the “Check
Connection”.
4.1.7 About the coexistence of NEC ESMPRO Manager with DianaScope
Agent or NEC ESMPRO Anget Extension on the same server
If the managed server is installed Advanced Remote Management Card or EXPRESSSCOPE Engine series
(the BMC uses exclusive LAN port (management LAN port)), NEC ESMPRO Manager can manage the server itself installed. Notice that you cannot use the GUI Remote Console function,
It the managed server is installed BMC that uses the standard LAN port, NEC ESMPRO Manager cannot manage the server itself installed. It is possible only to install NEC ESMPRO Manager and DianaScope
Agent or NEC ESMPRO Agent Extension on the same server. But the communication with BMC on the server is prevented by local loopback function of OS and the BMC cannot receive any packets from the NEC
ESMPRO Manager.
31
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
32
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
4.2 About managed server
4.2.1 About Windows Firewall
If Windows firewall is enabled on the managed server, DianaScope Agent or NEC ESMPRO Agent
Extension may not work correctly.
Please perform following settings:
(1) Open “Windows firewall” from “control panel” of Windows.
(2) Select “Add Port” on “Exceptions” tab page.
(3) Enter following setting:
Port number: Port number that you need to add.
If DianaScope Manager cannot communicate with DianaScope Agent or NEC
ESMPRO Agent Extension:
47120 – 47129
If the remote console does not display the Windows screen of the managed server:
The setting of GUI remote console function is enabled: 47130
The setting of GUI remote console function is disabled: 5900
TCP/UDP: TCP
See 4.2.2.5”About Windows Server 2003 x64 Edition” for remote console function.
4.2.2 About Remote Console
The SOL (Serial over LAN) system implements a CUI remote console via LAN by the following method: the
BMC gets redirection data that has been output to the serial port 2 by System BIOS or console-less OS and transmits the data via the LAN. If the remote console has been set in the BMC configuration information, the serial port 2 (COM2) cannot be used for connecting another device such as UPS because the BMC occupies the serial port 2.Please refer to “Appendix C. Managed Servers Summary” of the “NEC ESMPRO Manager
Ver.5 Setup Guide” to confirm the managed server supports SOL.
The remote console of Linux or SAC (Special Administration Console) of Windows Server 2003 can be used when the managed server support SOL. However, there are the following notes:
-- Use of serial port 2 is restricted. See 2.4.1 ”Notes on Managed Servers and Network Devices”.
There are the following notes in the managed server which does not support SOL:
-- Do not attempt to boot Windows or Linux on the managed server when you use Remote Control function with utility boot mode via LAN connection. Booting of Windows or Linux may result in a failure.
-- To operate RAID EzAssist for a SOL-incompatible managed server from the CUI remote console via LAN, set the item “Console Redirection” to “Disable” on the BIOS Setup Utility screen, reboot the system, and then boot the RAID EzAssist Configuration Utility.
-- The remote console by the redirection function of Linux and the remote console of SAC (Special
Administration Console) of Windows Server 2003 cannot be used via LAN.
4.2.2.2 About video adapter
When the managed server does not use the driver corresponding to the video adapter, the remote console of
NEC ESMPRO Manager may not display the Windows screen.
If the remote console does not display the Windows screen of the managed server, please confirm a setting
33
NEC ESMPRO Manager Ver.5 Installation Guide (Linux) shown below at the managed server side.
-- The driver corresponding to the video adapter is set in properties for Display of Windows.
4.2.2.3 Power Control with the BIOS Setup Utility Active
Do not control the power supply while the BIOS Setup Utility is active on the managed server. Otherwise, the alert setting of BMC configuration will be disabled.
4.2.2.4 CUI Remote Console of DOS
To execute the CUI remote console function of the DOS screen, select “Server” -> “Console Redirection” and change “ACPI Redirection” to “Disable” on the BIOS Setup Utility screen of the managed server if
“ACPI Redirection” exists on the “Console Redirection”.
4.2.2.5 About Windows Server 2003 x64 Edition
If OS of managed server is Windows Server 2003 x64 Edition, the remote console of NEC ESMPRO
Manager may not display the Windows screen correctly. Please perform following settings:
(1) To open the properties dialog box of VNC, click “Start” -> “All Programs” -> “VNC” ->
“Administrative Tools” -> “Slow Default Settings”.
(2) Change following settings in “Update Handling”:
- Uncheck “Poll Console Windows Only”.
- Check “Poll Window Under Cursor”.
(3) Click “OK”.
4.2.2.6 CUI Remote Console after Windows Boot
-- The remote console via LAN cannot be used for SAC if the managed server does not support SOL.
-- To execute the CUI remote console function of the SAC screen after Windows boot, select “Server” ->
“Console Redirection” and change “ACPI Redirection” to “Enable” on the BIOS Setup Utility screen of the managed server. When “ACPI Redirection” is set to “Enable” on the BIOS Setup Utility screen, the
CUI remote console function cannot be executed after POST.
If “ACPI Redirection” does not exist on the “Console Redirection” menu, please confirm that “Console
Redirection after POST” is enabled.
4.2.2.7 CUI Remote Console under Linux
-- The remote console by the redirection function of Linux cannot be used via LAN if the managed server does not support SOL.
-- To execute the CUI remote console function of the Linux redirection, select “Server” -> “Console
Redirection” and change “ACPI Redirection” to “Disable” on the BIOS Setup Utility screen of the managed server if “ACPI Redirection” exists on the “Console Redirection”.
-- When you execute a remote console by the redirection function of Linux, following settings are necessary.
(1) Set as following example at the line that begins with “kernel/vmlinuz” in the setting file
(/boot/grub/grub.conf) on Linux: console=tty0 console=ttyS1,19200n8r
34
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
(2) Make a setting like the following example in the setting file (/etc/inittab) on Linux:
S0:2345:respawn:/sbin/agetty –h –L 19200 ttyS1 vt100
(Explanation of the example setting)
“agetty” is to be used in the following conditions:
* Hardware control (RTS/CTS) is enabled. (This setting is an example. Determine whether to enable/disable it, conforming to the configuration information setting on the managed server.)
* A directly connected local line not requiring carrier detection is assumed.
* Baud rate 19200 bps (This setting is an example. Set the baud rate conforming to the BMC configuration information setting on the managed server.)
* Serial1 port 2 of the managed server is used.
* The terminal type is vt100.
-- Even if connection with a managed server is of any type (LAN, WAN, or Direct), Linux on the managed server recognizes that operation through the remote console of the DianaScope Manager is connection via the serial port. The initial setting on Linux does not permit any super-user (root) to log in via the serial port.
To log in as a super-user, disable the security function for the serial port 2. Be very careful of operation in this case.
To disable the security function for the serial port 2, add “ttyS1” to the /etc/security file.
-- To display the editor or menu screen on the CUI remote console, set the OS terminal screen to the
80-column, 24-line size.
4.2.2.8 In case of Change of the authentication key
If you do not use DianaScope Agent ver.2.00.00 and above, please execute either way below when you change the authentication key of the configuration information,
-- Reboot the managed server.
-- Restart the VNC service on the managed server.
4.2.2.9 About GUI Remote Console
When the OS of the managed server is Windows Server 2008, this function is disabled.
35
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
4.3 About BMC Configuration
4.3.1 About BMC Configuration tool
Among the BMC configuration information tools there are some tools which cannot be used to setup
ESMPRO.
-- NEC MWA Agent cannot be used.
-- If the DianaScope is not stored in the NEC EXPRESSBUILDER CD-ROM, “A setup of a system management” stored in the CD-ROM cannot be used.
-- The Console-less function of the NEC EXPRESSBUILDER can be used only when ESMPRO is stored in the same NEC EXPRESSBUILDER CD-ROM.
4.3.2 In Case of Exchange of management PC
If a management PC as an alert receiver has been exchanged, register the managed server’s BMC configuration information again even when the IP address of the management PC remains unchanged.
Otherwise, the BMC may fail to recognize the alert receiver.
4.3.3 About the function “Obtain an IP Address automatically (DHCP)
The managed server included the BMC that uses an exclusive LAN port (Management LAN port) supports the function “Obtain an IP Address automatically (DHCP)”.
(1) Following version of NEC ESMPRO Manager modules supports the setting of the function.
Managed server
The managed server that integrates DianaScope Agent
EXPRESSSCOPE Engine series. DianaScope Configuration
The managed server installed Advanced
Remote Management Card.
DianaScope Agent
DianaScope
DianaScope Configuration
Ver.2.03.05 and above
Ver.1.02 and above
Ver.2.06.00 and above
Ver.1.02 and above
When you use the module that does not support the setting of the function “Obtain an IP Address automatically (DHCP)” for the managed server that supports the function, please note followings:
-- If DianaScope Agent does not support the setting of the function, the DianaScope Agent always set
“disable” for the function when it registers the BMC configuration. The DianaScope Agent also set
“disable” when it writes the BMC configuration information file.
-- If DianaScope Configuration does not support the setting of the function, the DianaScope Configuration always set “disable” for the function when it writes the BMC configuration information file.
-- If “System Management” tool on NEC EXPRESSBUILDER does not support the setting of the function, the tool always set “disable” for the function when it registers the BMC configuration. The tool also set
“disable” when it writes the BMC configuration information file.
-- If remote console feature of NEC EXPRESSBUILDER does not support the setting of the function, the tool always set “disable” for the function when it registers the BMC configuration.
(2) If the managed server has been installed Advanced Remote Management Card, the BMC may not immediately obtain the IP address after DianaScope PXE Service configures the BMC to obtain the IP address by the DHCP. Please turn the managed server AC-OFF and then AC-ON because the BMC try to obtain the IP address whenever the managed server is turned AC-ON.
4.3.4 About shutdown OS
When the screen of a managed server is rocked (for example, by screen saver with password), DianaScope
Agent or NEC ESMPRO Agent Extension cannot shutdown OS of the managed server.
36
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
4.3.5 About shutdown OS during DC-OFF state by scheduled running
When “Agent Setting” – “Shut down OS after DC-ON during Scheduled Running Halt” on NEC ESMPRO
Manager is enabled, the DianaScope Agent or NEC ESMPRO Agent Extension shutdowns OS if the managed server is powered up during the down period (DC OFF state time by scheduled running).
Only if the managed server is powered up from NEC ESMPRO Manager, DianaScope Agent or NEC
ESMPRO Agent Extension does not shutdown OS. However, in case that any error is occurred during booting, DianaScope Agent or NEC ESMPRO Agent Extension may shutdown OS even though power up by
NEC ESMPRO Manager.
4.3.6 About the Port that BMC uses
In case that Linux on the managed server uses port 623, NEC ESMPRO Manager cannot communicate with the BMC that uses standard LAN port.
Please perform following settings:
(1) Add following entries in services files (/etc/services) to reserve port 623. asf-rmcp 623/tcp ASF Remote Management and Control Protocol asf-rmcp 623/udp ASF Remote Management and Control Protocol
(2) Reboot the OS.
4.3.7 About the initialization of the BMC Configuration Information setting
When you set “Default value” on the BMC Configuration Information with DianaScope Agent or NEC
ESMPRO Agent Extension, or create New Configuration with “System Management Tool” started from NEC
EXPRESSBUILDER CD-ROM, each items of the BMC Configuration Information are initialized.
If the managed server integrates EXPRESSSCOPE Engine series or Advanced Remote Management Card, following items for BMC Web server are also initialized because they are shared with BMC Configuration
Information:
DHCP Configuration
IP Address
Subnet Mask
Default Gateway
How to set the Web server is following:
- Select “System Management Tool” on “Tool” started from NEC EXPRESSBUILDER CD-ROM, and then select “Web server of BMC”.
- Login to Web server of the BMC, and then select “Configuration” – “Network”.
37
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
4.4 About Web client
4.4.1 About the operation from two or more browsers
NEC ESMPRO Manager cannot be operated using two or more browser windows by one Web client. When you use the browser which has tabbed browsing, the NEC ESMPRO Manager cannot be operated using two or more tab.
4.4.2 About downloading configuration information file
When you try to download the file from “Configuration Information File” of “Linkage Service” on NEC
ESMPRO Manager, Internet Explorer may block the download. Internet Explorer will also display the message on the information bar.
In this case, you can download the file with following settings:
(1) Click information bar on Internet Explorer.
(2) Click “Download File”.
(3) Please read the information carefully, and select “save”.
4.4.3 About the login to EXPRESSSCOPE Engine series
4.4.3.1 About Java Plug-in
To login to EXPRESSSCOPE Engine series through ESMPRO, Java plug-in of the web browser should be version 1.4.2_12 and above. If JAVA plug-in version is 1.4.2_11 and below, the web browser may stall.
4.4.3.2 About Microsoft Internet Explorer
The “login to EXPRESSSCOPE Engine series” screen might not be displayed.
In this case, add URL of the EXPRESSSCOPE Engine series to “Add this Web site to the zone”.
(1) Select “Internet Options” on “Tools” menu of Internet Explorer.
(2) Click the Security tab.
(3) Click “Local Internet” zone, and then click “Sites”.
(4) Enter the URL of the EXPRESSSCOPE Engine series on “add this Web site to the zone”.
For example: If the EXPRESSSCOPE Engine series has IP address 192.168.0.100, the URL is
“http://192.168.0.100”.
(5) Click “add” zone, and then click “OK”.
The screen including Java Applet might not be displayed on Internet Explorer.
Through the following procedure, the situation can be avoided.
--Disable the check box.
[Java control panel] - [Advanced] tab
“Enable the next-generation Java Plug-in”
The screen including Java Applet might not be displayed on Firefox.
Through the following procedure, the situation can be avoided.
-- Modify the version of Java Plug-in of Web browser.
-- Use Internet Explorer.
-- Disable the check box.
[Java control panel] - [Advanced] tab
“Enable the next-generation Java Plug-in”
38
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
Revision History
2009/01/30 1.01 Appends about the NEC ESMPRO Agent Extension.
NEC ESMPRO Manager Installation Manual
© NEC Corporation 2009
39
NEC ESMPRO Manager Ver.5 Installation Guide (Linux)
40
Unduh
Iklan