Digital indicator, model DI35-D
EN
Digital indicator for panel mounting
EN
Operating instructions model DI35-D Page 3 - 61
© 2017 WIKA Alexander Wiegand SE & Co. KG
All rights reserved.
WIKA ® is a registered trademark in various countries.
Prior to starting any work, read the operating instructions!
Keep for later use!
2 WIKA operating instructions digital indicator, model DI35-D
Contents
Contents
1. General information
2. Design and function
2.1 Overview, version for panel mounting . . . . . . . . . . . . . . . . 7
6
7
2.2 Overview, version in desktop case . . . . . . . . . . . . . . . . . 8
2.3 Description . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.4 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . 9
3. Safety 10
3.1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . 10
3.2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.3 Improper use. . . . . . . . . . . . . . . . . . . . . . . . . 11
3.4 Personnel qualification . . . . . . . . . . . . . . . . . . . . . 12
3.5 Labelling, safety marks . . . . . . . . . . . . . . . . . . . . . 13
4. Transport, packaging and storage 14
4.1 Transport . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.2 Packaging and storage . . . . . . . . . . . . . . . . . . . . . 14
5. Commissioning 15
5.1 Requirements for the installation location . . . . . . . . . . . . . . . 15
5.2 Mounting, version for panel mounting . . . . . . . . . . . . . . . . 15
5.3 Mounting, version in desktop case . . . . . . . . . . . . . . . . . 16
5.4 Electrical connection . . . . . . . . . . . . . . . . . . . . . . 16
5.4.1 Notes on installation. . . . . . . . . . . . . . . . . . . . 16
5.4.2 Pin assignment, version for panel mounting . . . . . . . . . . . . 17
5.4.3 Pin assignment, version in desktop case . . . . . . . . . . . . . 18
5.5 Interface connector . . . . . . . . . . . . . . . . . . . . . . 19
5.6 Switching on the digital indicator . . . . . . . . . . . . . . . . . . 19
5.7 Connection examples, version for panel mounting . . . . . . . . . . . . 20
6. Operation 22
6.1 Key functions. . . . . . . . . . . . . . . . . . . . . . . . . 22
6.2 Accessing and exiting programming mode. . . . . . . . . . . . . . . 22
6.3 Navigating in the menu . . . . . . . . . . . . . . . . . . . . . 23
6.4 Changing numerical values . . . . . . . . . . . . . . . . . . . . 23
6.5 Accessing or clearing MIN/MAX values . . . . . . . . . . . . . . . . 23
6.6 Switching display between measuring inputs . . . . . . . . . . . . . . 24
EN
WIKA operating instructions digital indicator, model DI35-D 3
Contents
EN
7. Description of program numbers 25
7.1 Setting measuring inputs. . . . . . . . . . . . . . . . . . . . . 25
7.1.1 Input signal . . . . . . . . . . . . . . . . . . . . . . . 25
7.1.2 Start and end value . . . . . . . . . . . . . . . . . . . . 26
7.1.3 Number of decimal places. . . . . . . . . . . . . . . . . . 27
7.1.4 Offset adjustment . . . . . . . . . . . . . . . . . . . . 27
7.2 General settings . . . . . . . . . . . . . . . . . . . . . . . 27
7.2.1 Default display. . . . . . . . . . . . . . . . . . . . . . 27
7.2.2 Switching of measuring inputs . . . . . . . . . . . . . . . . 28
7.2.3 Refresh rate . . . . . . . . . . . . . . . . . . . . . . 29
7.2.4 Measuring time . . . . . . . . . . . . . . . . . . . . . 29
7.2.5 Display brightness . . . . . . . . . . . . . . . . . . . . 29
7.3 Arithmetic function . . . . . . . . . . . . . . . . . . . . . . . 29
7.4 Setting the analogue output (option) . . . . . . . . . . . . . . . . . 30
7.4.1 Start and end value . . . . . . . . . . . . . . . . . . . . 30
7.4.2 Reference value . . . . . . . . . . . . . . . . . . . . . 31
7.4.3 Output signal . . . . . . . . . . . . . . . . . . . . . . 31
7.4.4 Example. . . . . . . . . . . . . . . . . . . . . . . . 31
7.5 Setting the serial interface (option) . . . . . . . . . . . . . . . . . 32
7.6 Setting user authorisations . . . . . . . . . . . . . . . . . . . . 33
7.6.1 Authorisation levels . . . . . . . . . . . . . . . . . . . . 33
7.6.2 Cancelling the password protection . . . . . . . . . . . . . . 33
7.7 Setting special functions . . . . . . . . . . . . . . . . . . . . . 34
7.7.1 Function of the digital input . . . . . . . . . . . . . . . . . 34
7.7.2 Function of the multi-function key . . . . . . . . . . . . . . . 34
7.7.3 TARE function . . . . . . . . . . . . . . . . . . . . . . 34
7.7.4 HOLD function . . . . . . . . . . . . . . . . . . . . . 35
7.8 Setting switching outputs . . . . . . . . . . . . . . . . . . . . 36
7.8.1 Flashing display on reaching the switch points . . . . . . . . . . . 36
7.8.2 Reference value . . . . . . . . . . . . . . . . . . . . . 36
7.8.3 Switch points . . . . . . . . . . . . . . . . . . . . . . 37
7.8.4 Switch behaviour . . . . . . . . . . . . . . . . . . . . . 37
7.9 Linearising sensors . . . . . . . . . . . . . . . . . . . . . . 42
7.10 Reading the serial number . . . . . . . . . . . . . . . . . . . . 44
7.11 Restoring factory settings . . . . . . . . . . . . . . . . . . . . 44
4 WIKA operating instructions digital indicator, model DI35-D
Contents
8. Faults 44
9. Maintenance and cleaning 47
9.1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . 47
9.2 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . 47
10. Dismounting, return and disposal 48
10.1 Dismounting, version for control panel . . . . . . . . . . . . . . . . 48
10.2 Return . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
10.3 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . 48
11. Specifications 49
Appendix 1: Overview of program numbers 55
Declarations of conformity can be found online at www.wika.com.
EN
WIKA operating instructions digital indicator, model DI35-D 5
1. General information
1. General information
EN
■ The digital indicator described in these operating instructions has been designed and manufactured using state-of-the-art technology. All components are subject to stringent quality and environmental criteria during production. Our management systems are certified to ISO 9001 and ISO 14001.
■ These operating instructions contain important information on handling the instrument. Working safely requires that all safety instructions and work instructions are observed.
■ Observe the relevant local accident prevention regulations and general safety regulations for the instrument's range of use.
■ The operating instructions are part of the product and must be kept in the immediate vicinity of the instrument and readily accessible to skilled personnel at any time. Pass the operating instructions on to the next operator or owner of the instrument.
■ Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work.
■ The general terms and conditions contained in the sales documentation shall apply.
■ Subject to technical modifications.
■ Further information:
- Internet address:
- Relevant data sheet:
- Application consultant: www.wika.de / www.wika.com
AC 80.03
Tel.: +49 9372 132-0
Fax: +49 9372 132-406 [email protected]
6 WIKA operating instructions digital indicator, model DI35-D
2. Design and function
2. Design and function
2.1 Overview, version for panel mounting
Designation
Key [☼]
Key [▼]
Key [▲]
Key [○]
Switch point display
Mounting element with clamping screw
7-segment display
Product label
Description
Programming mode is accessed
Changes to a deeper parameter level
MIN memory is accessed
Changes lower limit values
Changes between parameters
Changes parameter values
MAX memory is accessed
Changes lower limit values
Changes between parameters
Changes parameter values
Multi-function key
Displays the status of the switching outputs
Used for fixing
Displays measured values, program numbers or parameters
Contains product information
WIKA operating instructions digital indicator, model DI35-D 7
EN
EN
2. Design and function
2.2 Overview, version in desktop case
(267 incl.
displa
250
mm
inc l. An zeig e un d A
250 m sste cke r oh ne G ege nste cke r)
170
mm
Plug A Plug C
3
2
4
1
4
3
5 6 1
2
3
2
4
1
1
4
6
2
8
5
3
7
Plug B Plug D
Designation
Digital indicator (→ for description see chapter 2.1)
Mains plug with switch
Plug A (measuring input 1)
Plug B (measuring input 2)
Plug C (switching outputs)
Plug D (transmitter power supply, analogue output, serial interface)
8 WIKA operating instructions digital indicator, model DI35-D
2. Design and function
2.3 Description
The model DI35 digital indicator is a multi-function and very accurate instrument for a wide variety of measuring tasks.
The DI35-D is equipped with two inputs for standard signals (0/4 … 20 mA and DC 0 …
10 V) that can be used in any combination. The display can show one of the two input signals or a calculated value. Calculations can be made by means of the four basic arithmetic operations (+ - * /) and an additional constant multiplier.
In addition, both versions offer the possibility to calibrate sensors and linearise using up to 30 points. This allows further adaptation of the displayed values to different sensor signals and application requirements. The standard features are completed by a transmitter power supply, a HOLD function and a TARE function for the correction of offset shifts and sensor drifts. The sampling rate and display time can be configured and the display can be dimmed. Unauthorised alteration of the set instrument parameters can be prevented via different user levels, in conjunction with a freely selectable access code.
Optionally available are up to four freely configurable switch contacts, an analogue output signal and a serial interface.
EN
Functions
■
■
■
■
■
■
■
■
Calculation function (4 basic calculation types, constant multiplier)
Analogue output
Retrieval of the MIN/MAX value
HOLD and TARE function
Linearisation of the measuring input
Semiconductor switching outputs (option)
Switch point display (option)
Adjustable switch points (option)
2.4 Scope of delivery
Version for panel mounting
■
■
■
■
■
Digital indicator
Sealing
2 mounting elements
Operating instructions
Unit characters
WIKA operating instructions digital indicator, model DI35-D 9
2. Design and function / 3. Safety
EN
Version in desktop case
■
■
■
■
■
Digital indicator
Mains connection cable with connector per CEE 7/4
Operating instructions
Unit characters
Mating connector connections
In place of the mains connection cable supplied, other mains connection cables can be used so long as they fulfil the following characteristics:
■
■
■
Connector per IEC 60320 C13 for connection to the instrument
Protective conductor available
Cable is certified and approved by a recognised notified body for the country of operation
Cross-check scope of delivery with delivery note.
3. Safety
3.1 Explanation of symbols
DANGER!
... identifies hazards caused by electrical power. Should the safety instructions not be observed, there is a risk of serious or fatal injury.
WARNING!
... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or damage to equipment or the environment, if not avoided.
Information
... points out useful tips, recommendations and information for efficient and trouble-free operation.
10 WIKA operating instructions digital indicator, model DI35-D
3. Safety
3.2 Intended use
The DI35 digital indicator is designed for the evaluation and display of sensor signals.
With the switching outputs, it is possible to realise simple control functions.
The digital indicator is suitable only for indoor applications with pollution degree 2 and overvoltage category II.
This is a class B instrument for emissions and is intended for use in industrial environments. In other environments, e.g. residential or commercial installations, it can interfere with other equipment under certain conditions. In such circumstances the operator is expected to take the appropriate measures.
Only use the digital indicator in applications that lie within its technical performance limits (e.g. max. ambient temperature).
→ For performance limits see chapter 11 “Specifications”.
The instrument has been designed and built solely for the intended use described here, and may only be used accordingly.
The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use.
EN
3.3 Improper use
WARNING!
Injuries through improper use
Improper use of the instrument can lead to hazardous situations and injuries.
▶ Refrain from unauthorised modifications to the instrument.
▶ Do not open the instrument.
▶ Do not use the instrument within hazardous areas.
Any use beyond or different to the intended use is considered as improper use.
WIKA operating instructions digital indicator, model DI35-D 11
3. Safety
EN
3.4 Personnel qualification
WARNING!
Risk of injury should qualification be insufficient
Improper handling can result in considerable injury and damage to equipment.
▶ The activities described in these operating instructions may only be carried out by personnel who have the qualifications described below.
Skilled electrical personnel
Skilled electrical personnel are understood to be personnel who, based on their technical training, know-how and experience as well as their knowledge of country-specific regulations, current standards and directives, are capable of carrying out work on electrical systems and independently recognising and avoiding potential hazards. The skilled electrical personnel have been specifically trained for the work environment they are working in and know the relevant standards and regulations. The skilled electrical personnel must comply with current legal accident prevention regulations.
12 WIKA operating instructions digital indicator, model DI35-D
3. Safety
3.5 Labelling, safety marks
Product label, panel mounting
Power supply:
Input:
Product no:
Product code:
18...30V / 10...40V (max. 15VA)
2 x DC 0...10V ; DC 0/4...20mA
46855373
DI35-D-2Y5C32B-Z
Serial no: Serial No.
Alarm outputs
21 22 23 24 25 26 27 28 29 30 31 32
Interface
RS-232
(not insulated)
41 42 43
Internal bridge
1 2 3 4 5 6 7 8 9 10 11 12 13 14
+ +
0/4-20mA 0/4-20mA
0-5/10V 0-5/10V
Pin assignment
Serial number
Specifications
Product label, desktop case
Pin assignment
Serial number
Serial no:
Alarm outputs
Serial no.
21 22 23 24 25 26 27 28 29 30 31 32
Internal bridge
1 2 3 4 5 6 7 8 9 10 11 12 13 14
+ +
0/4-20mA 0/4-20mA
0-5/10V 0-5/10V
EN
Symbols
Before mounting and commissioning the instrument, ensure you read the operating instructions!
WIKA operating instructions digital indicator, model DI35-D 13
4. Transport, packaging and storage
4. Transport, packaging and storage
EN
4.1 Transport
Check the digital indicator for any damage that may have been caused by transport.
Obvious damage must be reported immediately.
CAUTION!
Damage through improper transport
With improper transport, damage to property can occur.
▶ When unloading packed goods upon delivery as well as during internal transport, proceed carefully and observe the symbols on the packaging.
▶ With internal transport, observe the instructions in chapter 4.2
“Packaging and storage”.
4.2 Packaging and storage
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during transport (e.g. change in installation site, sending for repair).
Permissible conditions at the place of storage:
■
■
Storage temperature: -20 ... +80 °C
Humidity: 0 ... 75 % relative humidity (no condensation)
Avoid exposure to the following factors:
■
■
■
Direct sunlight or proximity to hot objects
Mechanical vibration, mechanical shock (putting it down hard)
Soot, vapour, dust and corrosive gases
Store the digital indicator in its original packaging in a location that fulfils the conditions listed above. If the original packaging is not available, pack and store the instrument as described below:
1. Wrap the instrument in a plastic film.
2. Place the instrument, along with shock-absorbent material, in the packaging.
14 WIKA operating instructions digital indicator, model DI35-D
5. Commissioning
5. Commissioning
If the instrument is transported from a cold into a warm environment, the formation of condensation may result in instrument malfunction. Before putting it into operation, wait for the instrument temperature and the room temperature to equalise.
EN
■
■
■
■
5.1 Requirements for the installation location
■ In the vicinity there should be no magnetic or electrical fields, e.g. from transformers,
■ radio-telephones or electrostatic discharges.
In the vicinity there should be no strong heat sources. The permissible operating temperature must not be exceeded (max. 50 °C).
The installation location must conform to pollution degree 2.
No direct sunlight or proximity to hot objects
No mechanical vibration, mechanical shock (putting it down hard)
No soot, vapour, dust and corrosive gases
5.2 Mounting, version for panel mounting
107,0
120
,0
3,0
96,0 139
,0
Mounting element with clamping screw
Sealing
Cutting out the control panel
■
■
Control panel thickness max. 15 mm
Panel cutout 92.0
+0.6
x 45.0
+0.3
mm
Recommended mounting grid: 120 mm horizontal, 96 mm vertical
WIKA operating instructions digital indicator, model DI35-D 15
5. Commissioning
EN
Installing the digital indicator
1. As required, slide the unit characters into the window provided via the lateral channel.
2. Remove the mounting elements.
3. Slide the seal over the digital indicator.
4. Slide the digital indicator into the control panel from the front.
Check the seal is properly seated.
5. Lock the mounting elements into place and tighten the clamping screws (max. 0.1 Nm).
5.3 Mounting, version in desktop case
▶ Connect the digital indicator to the socket using the mains connection lead.
5.4 Electrical connection
■
■
■
■
5.4.1 Notes on installation
■
■
The voltage supply must comply with overvoltage category II.
With the panel mounting version, protect the voltage supply with a slow fuse of max.
0.5 A. With the desktop case version, the fuse is integrated.
For the panel-mounting version, a suitable isolation device must be provided.
Route the signal input lines and signal output lines separately.
■
■
Route outward and return lines side-by-side.
Galvanically isolated potentials must be connected to a suitable point (e.g. earth or plant ground).
For high-accuracy requirements and small measuring signals, the sensor wires must be shielded and twisted. The shield should be connected at one end only to a suitable equipotential bonding (e.g. measurement ground).
Avoid electrostatic discharges in the area of the terminals.
16 WIKA operating instructions digital indicator, model DI35-D
5. Commissioning
5.4.2 Pin assignment, version for panel mounting
Terminal assignment (upper terminal block)
Switching outputs Serial interface
21 22 23 24 25 26 27 28 29 30 31 32 41 42 43
GND (RS)
RS 232
EN
GND (RS)
RS 485
For further information see chapter 11 “Specifications”
Terminal assignment (lower terminal block)
1 2
+
3 4 5 6 7 8 9 10 11 121314 l + l + l + l + L N
+
0/4 ... 20 mA l +
0/4 ... 20 mA l
0 ... 10 V 0 ... 10 V
For further information see chapter 11 “Specifications”
WIKA operating instructions digital indicator, model DI35-D 17
EN
5. Commissioning
5.4.3 Pin assignment, version in desktop case
Plug A (measuring input 1) Plug C (switching outputs)
Plug B (measuring input 2)
Plug D (digital input, analogue output, serial interface)
Power supply:
Input:
Product no:
Product code:
Serial no:
Alarm outputs
100..240V (max. 15VA)
2 x DC 0...10V ; DC 0/4...20mA
46857171
DI35-D-2W5CZJB-Z
Serial no.
21 22 23 24 25 26 27 28 29 30 31 32
Internal bridge
1 2 3 4 5 6 7 8 9 10 11 12 13 14
+ +
0/4-20mA 0/4-20mA
0-5/10V 0-5/10V
Suitable mating connectors are included in the delivery.
Depending on the version, not all connections are available (instruments without switch points do not feature a plug C, instruments without analogue output and serial interface do not feature plug D).
18 WIKA operating instructions digital indicator, model DI35-D
5. Commissioning
5.5 Interface connector
RS-232
The RS-232 interface cables must be connected 1:1 (TxD to TxD and RxD to RxD).
PC or
PLC
DI35
EN
RS-485
The RS-485 interface is connected via a shielded data cable with twisted pairs. At each end of the bus segment, a termination of the bus lines must be connected. This is needed in order to ensure safe data transfer over the bus. For this, a resistor (120 Ω) is inserted between data B (+) and data A (-).
PC or PLC
DATA B (+)
DATA A (―)
DI35
Where interfaces are not galvanically isolated, the potential reference between the interface and the measuring input can lead to a compensating current. This compensating current can influence the measuring signals.
5.6 Switching on the digital indicator
▶ Connect the power supply.
⇒ Segment test is carried out. Check the correct operation of all LEDs
Software type and software version are displayed.
⇒ Digital indicator is ready for operation.
WIKA operating instructions digital indicator, model DI35-D 19
EN
5. Commissioning
5.7 Connection examples, version for panel mounting
2-channel measurement with current signals, 2-wire transmitter, AC 100 ... 240 V supply
Input 1 Input 2
Analogue output
Transmitter power supply
Power supply
AC 100 ... 240 V
2-channel measurement with voltage signals, 3-wire transmitter, DC 10 ... 40 V supply
Input 1 Input 2
Analogue output
Transmitter power supply
Power supply
20
DC 10 ... 40 V
WIKA operating instructions digital indicator, model DI35-D
5. Commissioning
1-channel measurement with current signal in conjunction with digital signal and transmitter power supply, 2-wire transmitter, DC 100 ... 240 V supply
Input 1 Input 2
Analogue output
Transmitter power supply
Power supply EN
AC 100 ... 240 V
WIKA operating instructions digital indicator, model DI35-D 21
6. Operation
EN
6. Operation
6.1 Key functions
Key
Key [☼]
Key [☼] + [▼] [▲]
Key [▼]
Key [▲]
Key [○]
Function
Programming mode is accessed
Pressing < 1 s: Changes the cursor position
Pressing > 1 s: Saves all parameters
Scrolls through the program numbers (PN)
Pressing > 1 s: Automatically starts cycle
Pressing < 1 s: Selects or changes parameter
Pressing > 1 s: Switches the input channel display
Pressing < 1 s: Selects or changes parameter
Pressing > 1 s: Switches the input channel display
Multi-function key
Selects functions (e.g. HOLD or TARE)
6.2 Accessing and exiting programming mode
Accessing programming mode
▶ Press [☼].
⇒ Digital indicator is in programming mode
Lowest available program number is displayed.
→ Available program numbers are dependent upon the authorisation level, see chapter
7.6.1 “Authorisation levels”.
Exiting the programming mode
If no keys are pressed within 7 seconds, the digital indicator switches back to display mode.
22 WIKA operating instructions digital indicator, model DI35-D
6. Operation
6.3 Navigating in the menu
[☼]
PN0
[☼] 1s
[
▲/▼
]
[☼]+
[ ▲] [☼]+
[ ▼]
Parameter 1
Parameter 2
Parameter 3
PN1
[☼]+
[ ▲]
PN...
[☼]+
[ ▼]
[☼] 1s
[ ▲/▼ ]
6.4 Changing numerical values
Parameter [☼] 1. Zahl
[ ▲] [▼]
[☼] 1s
-9999 … 99999
[☼]
6.5 Accessing or clearing MIN/MAX values
Accessing MIN value
▶ Press [▼].
⇒ MIN value is displayed 7 s.
Accessing MAX value
▶ Press [▲].
⇒ MAX value is displayed 7 s.
Clearing MIN/MAX values
▶ Press [▼] + [▲].
⇒ Horizontal bars are displayed.
MIN/MAX values are cleared.
2. Zahl
[ ▲] [▼]
[ ▲]
[ ▼]
The MIN/MAX values are lost when the instrument is switched off.
EN
WIKA operating instructions digital indicator, model DI35-D 23
6. Operation
EN
6.6 Switching the display between measuring inputs
The switching of measuring inputs changes between the display values of the measuring inputs and the display value of the arithmetic calculation. The display value of the arithmetic calculation is only displayed when this has been configured.
The following methods are supported:
Method
Static
Triggered
Cyclic
Description
A preset display value is shown for the duration of the trigger signal.
With each trigger pulse, the measuring input is switched further (series Ch1, Ch2, Ar).
The change is made cyclically over a preset time interval
(series Ch1, Ch2, Ar).
For the trigger signal, the multi-function button or the digital input can be used (for programming, see chapter 7.6 “Switching of measuring inputs”)
Before each change, the description of the measuring input is displayed.
■
■
■
Measuring input 1 = Ch1
Measuring input 2 = Ch2
Arithmetic calculation = Ar
24 WIKA operating instructions digital indicator, model DI35-D
7. Description of program numbers
7. Description of program numbers
For an overview of the program numbers see appendix 1 “Overview of program numbers”
7.1 Setting measuring inputs
7.1.1 Input signal
The digital indicator features two measuring inputs. Each measuring input can be set for a different input signal.
EN
PN Function
0 Input signal, measuring input 1
5 Input signal, measuring input 2
Parameter
Factory calibration
1 = DC 0 ... 10 V
2 = 0 ... 20 mA
3 = 4 ... 20 mA
Sensor calibration
4 = DC 0 ... 10 V
5 = 0 ... 20 mA
6 = 4 ... 20 mA
Parameters 1 ... 3 Used for standardised input signals. There must be no signal applied to the measuring input. The corresponding display values can be manually assigned.
→ For assigning display values, see chapter 7.1.2 “Start and end value”
Parameters 4 ... 6 Used for non-standardised input signals. The signal must be applied to the measuring input and the corresponding display value manually assigned.
→ For assigning display values, see chapter 7.1.2 “Start and end value”
WIKA operating instructions digital indicator, model DI35-D 25
7. Description of program numbers
EN
7.1.2 Start and end value
With this value pair, the measuring signal is assigned the desired indication value.
PN Function
1
2
6
7
End value (end of measuring range)
Measuring input 1
Start value (start of measuring range)
Measuring input 1
End value (end of measuring range)
Measuring input 2
Start value (start of measuring range)
Measuring input 2
Parameter
-9999 ... 99999
-9999 ... 99999
-9999 ... 99999
-9999 ... 99999
Procedure for standard signals
▶ Set the corresponding display values.
Procedure for non-standard input signals
1. Apply the end value of the input signal to the measuring input.
2. Select PN 1/PN 6.
3. Set the display value.
4. Press [☼].
⇒ Input signal is associated with display value.
5. Apply the start value of the input signal to the measuring input.
6. Select PN 2/PN 7.
7. Set the display value.
8. Press [☼].
⇒ Input signal is associated with display value.
Display values are assigned.
26 WIKA operating instructions digital indicator, model DI35-D
7. Description of program numbers
7.1.3 Number of decimal places
Specifies the number of decimal places that are displayed on the screen. This parameter has no influence on the scaling of the indication value.
PN
3
8
Function Parameter
Number of decimal places, measuring input 1 00000 ... 0.0000
Number of decimal places, measuring input 2 00000 ... 0.0000
7.1.4 Offset adjustment
The input signal is shifted in parallel by the offset value.
PN
4
9
Function
Offset value, measuring input 1
Offset value, measuring input 2
Parameter
-9999 ... 99999
-9999 ... 99999
EN
This parameter can be altered directly by making a tare if this was triggered through the multi-function button or the digital input.
7.2 General settings
7.2.1 Default display
Defines the measuring input which should be displayed as standard.
PN
10
Function
Default display
Parameter
1 = Measuring input 1
2 = Measuring input 2
3 = Arithmetic function
→ For arithmetic function see chapter 7.3 “Arithmetic function”.
WIKA operating instructions digital indicator, model DI35-D 27
7. Description of program numbers
EN
7.2.2 Switching of measuring inputs
The switching of measuring inputs changes between the display values of the measuring inputs and the display value of the arithmetic calculation. The display value of the arithmetic calculation is only displayed when this has been configured.
The following methods are supported:
Method
Static
Triggered
Cyclic
Description
A preset display value is shown for the duration of the trigger signal.
With each trigger pulse, the measuring input is switched further (series
Ch1, Ch2, Ar).
The change is made cyclically over a preset time interval (series Ch1,
Ch2, Ar).
For the trigger signal, the multi-function button or the digital input can be used (see chapter 7.7 “Setting special inputs”, PN 53/PN 54)
Before each change, the description of the measuring input is displayed.
■
■
■
Measuring input 1 = Ch1
Measuring input 2 = Ch2
Arithmetic calculation = Ar
PN
11
Function
Switching of measuring inputs
Parameter
0 = Key [▼] [▲] (triggered)
1 = Measuring input 1 (static)
2 = Measuring input 2 (static)
3 = Arithmetic function (static)
4 = Multi-function key (triggered)
5 = Cyclic (5 s)
6 = Cyclic (10 s)
7 = Cyclic (20 s)
28 WIKA operating instructions digital indicator, model DI35-D
7. Description of program numbers
7.2.3 Refresh rate
The refresh rate determines how often the display values are updated. With strongly fluctuating input signals, it is recommended that the refresh rate is adjusted (refresh rate
> 1s).
The refresh rate acts only on the presentation of the display values. Switching outputs and other functions are not affected.
EN
PN
13
Function
Refresh rate
Parameter
0.1 ... 10.0 s (default 1 s)
7.2.4 Measuring time
PN
14
Function
Measuring time
Parameter
0.04 ... 10.0 s (two measuring inputs)
0.02 ... 10.0 s (one measuring input)
7.2.5 Display brightness
PN
19
Function
Display brightness
Parameter
0 ... 9 (0 = bright, 9 = dark)
7.3 Arithmetic function
Calculation type
Addition
Subtraction
Multiplication
Ratio
Percent
Formula
(Measuring input 1 + measuring input 2) ∙ constant
(Measuring input 1 + measuring input 2) ∙ constant
(Measuring input 1 ∙ measuring input 2) ∙ constant
(Measuring input 1 / measuring input 2) ∙ constant
(Measuring input 1 ∙100 ) / measuring input 2
Calculation type
Addition
Subtraction
Multiplication
Ratio
Percent
Example applications
Inflow and outflow quantities, weighing technology
Differential measurement (e.g. differential pressure)
Power and energy measurement
Mixing ratios
Percentage ratios
WIKA operating instructions digital indicator, model DI35-D 29
EN
16
17
18
7. Description of program numbers
PN
15
Function
Calculation type
Constant
Number of decimal places of constants
Number of decimal places of calculation
Parameter
1 = Measuring input 1 ∙ constant
2 = Measuring input 2 ∙ constant
3 = Addition
4 = Subtraction
5 = Multiplication
6 = Ratio
7 = Percent
-9999 ... 99999
00000 ... 0.0000
00000 ... 0.0000
With the calculation of the arithmetic function, all set decimal points are included (PN 3, PN 8, PN 17, PN 18)
7.4 Setting the analogue output (option)
The analogue output gives the measured values of the digital indicator as a standard signal (DC 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA).
7.4.1 Start and end value
The analogue output can be assigned any measuring input. The output signal is updated simultaneously with the measuring input. The refresh rate is determined by the configured measuring time. The start and end value for the analogue signal can be assigned user-defined measured values.
The start and end value defines at which display value the minimum and maximum output signal will be given. The display value is dependent upon the setting of the input signal ( see chapter 7.1.1 “Input signal”)
PN
20
21
Function
Full scale
Start value
Parameter
-9999 ... 99999
-9999 ... 99999
30 WIKA operating instructions digital indicator, model DI35-D
7. Description of program numbers
7.4.2 Reference value
The reference value is the value which is given via the analogue output.
PN
22
Function
Reference value
Parameter
0 = Analogue output deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Arithmetic function
7.4.3 Output signal
PN
23
Function
Output signal
Parameter
0 = DC 0 ... 10 V
1 = 0 ... 20 mA
2 = 4 ... 20 mA
In addition, the output signal must be set via the DIP switch on the rear of the instrument.
DC 0 ... 10 V = Switch set to the right
0/4 ... 20 mA = Switch set to the left
With the desktop case, the output signal is determined via the assignment of plug D (see pin assignment).
7.4.4 Example
A rotational speed of 0 ... 3,000 min-1 should be transmitted to a control room via
4 ... 20 mA. The rotational speed sensor is connected to measuring input 1.
1. Set the end value to 3,000.
2. Set the start value to 0.
3. Set the reference value to 1.
4. Set the output signal to 2.
5. Set the DIP switch.
⇒ Analogue output is set.
EN
WIKA operating instructions digital indicator, model DI35-D 31
7. Description of program numbers
7.5 Setting the serial interface (option)
PN
34
Function
Interface properties
Parameter
0 = Standard mode
1 = Sending mode
EN
Interface properties
Standard mode
(= Configuration mode)
Sending mode
Description
In this mode, the digital indicator can be configured. Responses will only be transmitted on request.
The current measured value can be queried via “A↵”.
Measured values are sent cyclically. The cycle corresponds to the set measuring time.
Cancel sending mode
The sending mode is cancelled on receipt of “> ↵” and the instrument returns to standard mode.
Activate sending mode
Restart the digital indicator or transmit the command “S ↵”.
Protocol structure
Display values are transmitted in ASCII format. Minus signs and decimal points can be displayed directly on a terminal display or processed by a PLC. Leading spaces are disabled with transmission. With an over- or underrange, hyphens are transmitted
“- - - - - ↵”.
Example: “0.00 ↵”; “-9.99 ↵” ; “999.99 ↵”; “-123.45”; “ - - - - - ↵”; “Lbr ↵”
The display values can be processed or stored on a PC via a terminal program.
Settings
■
■
■
■
■
Point-to-point connection
Transmission rate 9,600 baud
8 data bits without parity
1 stop bit
32 WIKA operating instructions digital indicator, model DI35-D
7. Description of program numbers
7.6 Setting user authorisations
7.6.1 Authorisation levels
Via the user authorisation, it is possible to limit which settings can be made by the operator. The authorisations can be allocated in different authorisation levels.
Function
Changing the display brightness
Allocating the locking code
Reading the serial number
Changing switch points
Setting the switching output
Setting the interface
Setting the analogue output
Setting measuring inputs
Carrying out a linearisation
Inputting a release code
Changing the authorisation level
PN
59 ... 95
32 ... 34
20 ... 22
0 ... 18
100 ... 170
51
52
Authorisation level
1 2 3 4 5 6 7 8
19
50
200
61, 71, 81, 91
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
The authorisation levels can only be changed if the release code corresponds to the locking code (password protection). On delivery, both parameters are set to the value
0000, whereby the programming lockout is deactivated.
-
-
-
-
-
-
-
PN
50
51
52
Function
Locking code
Release code
Authorisation level
Parameter
0000 ... 9999
0000 ... 9999
0 ... 8
7.6.2 Cancelling the password protection
The password protection is cancelled when the release code corresponds to the locking code.
EN
If the locking code is lost, the instrument can be reset by the manufacturer.
WIKA operating instructions digital indicator, model DI35-D 33
7. Description of program numbers
EN
7.7 Setting special functions
7.7.1 Function of the digital input
PN
53
Function
Function of the digital input
Parameter
0 = Deactivated
1 = Switching the measuring input
2 = HOLD
3 = TARE
7.7.2 Function of the multi-function key
PN
54
Function
Function of the multi-function key
Parameter
0 = Deactivated
1 = Switching the measuring input
2 = HOLD
3 = TARE
7.7.3 TARE function
The TARE function sets the display value of the stored measuring input to zero. The difference between zero and the display value is stored as an offset value.
The TARE function overrides a previously programmed offset shift of the measuring inputs (PN 4/9). Should the TARE function be used during a measurement, the offset shift has to be reprogrammed.
The TARE function can be activated through the multi-function key or the digital input
(→ see chapter 7.7 “Setting special functions”). The key must be activated for at least 3 seconds.
The tare operation is represented as follows:
34 WIKA operating instructions digital indicator, model DI35-D
7. Description of program numbers
PN
55
Function
TARE function
Parameter
0 = Deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Measuring input 1 + 2
7.7.4 HOLD function
The HOLD function freezes the current display value. This is signalled via a flashing display.
The HOLD function can be activated through the multi-function key or the digital input (→ see chapter 7.7 “Setting special functions”).
The HOLD function can be switched statically or triggered.
Method
Static
Triggered
Description
A display value is frozen for the duration of the trigger signal.
The display value is frozen as soon the trigger is activated for a short time. The function is reset when the trigger is activated again.
PN
56
Function
HOLD function
Parameter
0 = Deactivated
1 = Triggered
2 = Static
EN
WIKA operating instructions digital indicator, model DI35-D 35
7. Description of program numbers
EN
7.8 Setting the switching outputs
The switching outputs can be configured independently. Each switching output can be assigned a separate measuring input. The switching outputs react to the measuring input at any time, regardless of which measuring input is shown on the digital display.
7.8.1 Flashing display on reaching the switch points
A switch point being exceeded can be signalled via a simultaneous flashing of the
7-segment display and switch point display.
PN
59
Function
Flashing display
Parameter
0 = not flashing
1 = at switch point 1
2 = at switch point 2
3 = at switch point 3
4 = at switch point 4
5 = at switch point 1 + 2
6 = at switch point 3 + 4
7 = at switch point 1 + 2 + 3 + 4
Reading the switching status
The switching status of the switching outputs can be read from the switch point display.
Switch point display
7.8.2 Reference value
The reference value is the value to which the switching output reacts.
PN
60
70
80
90
Function
Reference value, switching output 1
Reference value, switching output 2
Reference value, switching output 3
Reference value, switching output 4
Parameter
0 = Deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Arithmetic function
36 WIKA operating instructions digital indicator, model DI35-D
7. Description of program numbers
7.8.3 Switch points
PN
61
71
81
91
Function
Switch point, switching output 1
Switch point, switching output 2
Switch point, switching output 3
Switch point, switching output 4
Parameter
-9999 ... 99999
-9999 ... 99999
-9999 ... 99999
-9999 ... 99999
7.8.4 Switch behaviour
84
94
65
93
64
74
75
85
95
82
92
63
73
83
PN
62
72
Function
Hysteresis, switching output 1
Hysteresis, switching output 2
Hysteresis, switching output 3
Hysteresis, switching output 4
Switching function, switching output 1
Switching function, switching output 2
Switching function, switching output 3
Switching function, switching output 4
Switching delay, switching output 1
Switching delay, switching output 2
Switching delay, switching output 3
Switching delay, switching output 4
Delay type, switching output 1
Delay type, switching output 2
Delay type, switching output 3
Delay type, switching output 4
Parameter
1 ... 99999
0 = Normally closed
1 = Normally open
0 ... 10 seconds
0 = none
1 = Switch-on delay
2 = Switch-off delay
3 = Switch-on and switch-off delay
EN
WIKA operating instructions digital indicator, model DI35-D 37
7. Description of program numbers
EN
Normally open
Below the switch point, the switching output is switched off. On reaching the switch point, the switching output is switched on.
The switching output is switched off only when the switch point, less the hysteresis, is reached.
38 WIKA operating instructions digital indicator, model DI35-D
7. Description of program numbers
Normally closed
Below the switch point, the switching output is switched on. On reaching the switch point, the switching output is switched off.
The switching output is switched on only when the switch point, less the hysteresis, is reached.
EN
WIKA operating instructions digital indicator, model DI35-D 39
7. Description of program numbers
EN
Switch-on delay
The switching output is switched on only when the input signal remains above the switch point for at least the set switching delay.
This function prevents an unwanted switching of the switching output as a result of a short-term fluctuation of the input signal.
40 WIKA operating instructions digital indicator, model DI35-D
7. Description of program numbers
Switch-off delay
The switching output is switched off only when the input signal remains under the switch point for at least the set switching delay.
This function prevents an unwanted switching of the switching output as a result of a short-term fluctuation of the input signal.
EN
WIKA operating instructions digital indicator, model DI35-D 41
7. Description of program numbers
EN
7.9 Linearising sensors
Non-linear sensors can be linearised with up to 30 interpolation points per measuring input.
At each interpolation point, the input signal is assigned a new display value manually.
The analogue output is also linearised since it is proportional to the display values.
Each interpolation point must have a higher input signal than the previous. The corresponding display values can be freely assigned.
PN
100
Function
Number of interpolation points, measuring input 1
Parameter
0 ... 30
101 ... 130 Display value for interpolation point, measuring input 1 -9999 ... 99999
140 Number of interpolation points, measuring input 2 0 ... 30
141 ... 170 Display value for interpolation point, measuring input 2 -9999 ... 99999
Procedure
1. Set the number of interpolation points under PN 100/PN 140.
2. Apply the input signal for the first interpolation point, PN 101/PN 141, at the measuring input.
3. Set the desired display value under PN 101/PN 141.
⇒ Input signal is associated with display value.
4. Repeat steps 2 + 3 for all interpolation points.
⇒ Input signal is linearised.
42 WIKA operating instructions digital indicator, model DI35-D
7. Description of program numbers
Example
Linearisation of a pressure sensor for 0 ... 100 mbar with an output signal of 0 ... 20 mA.
■
■
Programming with 5 interpolation points.
Non-linear range 0 ... 75 mbar.
Interpolation point
PN 2
PN 101
PN 102
PN 103
PN 104
PN 105
PN 1
Pressure
[mbar]
40
60
75
0
15
30
100
Transmitter output signal [mA]
0.5
3.3
6.2
9.2
11.4
14.7
20
Display value [mbar] before linearisation after linearisation
2.5
0.0
16.5
31.0
46
57
73.5
100.0
15.0
30.0
40.0
60.0
75.0
100.0
For PN 101 this means:
With a pressure of 15 mbar, the transmitter delivers an output signal of 3.3 mA instead of 3.0 mA. Therefore, before correction, the display shows 16.5 mbar. This value is adjusted to 15.0 mbar using the interpolation point.
EN
100
90
80
70
40
30
20
10
60
50
104
105
102
103
101
10 20 30 40 50 60 70 80 90 100 110
WIKA operating instructions digital indicator, model DI35-D 43
7. Description of program numbers / 8. Faults
7.10 Reading the serial number
PN
200
Function
Serial number
Parameter
0 ... 99999
EN
7.11 Restore factory settings
The factory settings can only be restored if the programming lock PN 50 allows access to all PNs or HELP is displayed. All application-specific data will be lost.
1. Switch off the power supply.
2. Press the multi-function key.
3. Apply power supply and hold the multi-function key for 2 s.
⇒ Factory settings are restored.
8. Faults
CAUTION!
Physical injuries and damage to property and the environment
If faults cannot be eliminated by means of the measures listed above, the instrument must be taken out of service immediately.
▶ Ensure that pressure or signal is no longer present and protect against accidental commissioning.
▶ Contact the manufacturer.
▶ If a return is needed, follow the instructions given in chapter 10.2
“Returns”.
Faults
Instrument shows permanent overrange
Causes
One of the measuring inputs has a very high measured value
With a measuring input with a small voltage signal, this is only connected on one side or the input is open
Not all activated interpolation points are parameterised
The arithmetic result gives an overrange
Measures
Check measuring path
Check relevant parameter
44 WIKA operating instructions digital indicator, model DI35-D
8. Faults
Faults
Instrument shows a permanent underrange
Instrument displays “HELP”
Display values are changing in very large jumps
Program numbers are not available
Causes
One of the measuring inputs has a very small measured value
With a measuring input with a small voltage signal, this is only connected on one side or the input is open
Not all activated interpolation points are parameterised
The arithmetic result gives an underrange
Error in the configuration memory
With a division, the measured value of the divisor is very small small
Access through user authorisation denied
Set sensor type is preventing the desired program number from being parameterised
The analogue output is an option. If this is not implemented, then the program numbers are hidden
Instrument displays “Err1”
Digital input does not react
Measures
Check measuring path
Check relevant parameter
Restore factory settings and re-enter the settings
Check measuring path
Contact the manufacturer
Measure input current of digital input. It should lie between 1 ... 3 mA.
EN
WIKA operating instructions digital indicator, model DI35-D 45
8. Faults
EN
Overrange and underrange display
Each over- or underrange of a measuring input relates to a defined display. This definition ensures that the appropriate switch points go to a defined state.
Calculation type
Addition
Subtraction
Multiplication
Division
Percent
Channel 1
Overrange
Underrange
OK or overrange
OK or underrange
Overrange
Overrange
Underrange
OK or overrange
OK or underrange
Overrange
Overrange
Underrange
OK or overrange
OK or underrange
Overrange
Overrange
Underrange
OK
OK
Overrange
Underrange
OK
OK
Channel 2
OK or overrange
OK or underrange
Overrange
Underrange
Underrange
OK or overrange
OK or underrange
Overrange
Underrange
Underrange
OK or overrange
OK or underrange
Overrange
Underrange
Underrange as required as required
Overrange
Underrange as required as required
Overrange
Underrange
Results
Overrange
Underrange
Overrange
Underrange
Overrange
Overrange
Underrange
Overrange
Underrange
Overrange
Overrange
Underrange
Overrange
Underrange
Overrange
Overrange
Underrange
Underrange
Underrange
Overrange
Underrange
Underrange
Underrange
Illustration of overrange Illustration of underrange
46 WIKA operating instructions digital indicator, model DI35-D
9. Maintenance and cleaning
9. Maintenance and cleaning
9.1 Maintenance
This digital indicator is maintenance-free.
Repairs must only be carried out by the manufacturer.
9.2 Cleaning
DANGER!
Danger to life caused by electric current
Upon contact with live parts, there is a direct danger to life.
▶ Only clean the case and contacts when the current is disconnected.
CAUTION!
Unsuitable cleaning agents
Cleaning with unsuitable cleaning agents may damage the instrument and the product label.
▶ Do not use any aggressive cleaning agents.
▶ Do not use any hard or pointed objects.
▶ Do not use any abrasive cloths or sponges.
EN
1. Disconnect the digital indicator from the supply.
2. Wipe the instrument surface using a soft, damp cloth.
WIKA operating instructions digital indicator, model DI35-D 47
10. Dismounting, return and disposal
10. Dismounting, return and disposal
EN
10.1 Dismounting, version for control panel
1. Disconnect the digital indicator from the supply.
2 .
Disconnect the electrical connection.
3 .
Remove the mounting elements.
4. Pull the digital indicator out of the control panel.
10.2 Return
Strictly observe the following when shipping the instrument:
All instruments delivered to WIKA must be free from any kind of hazardous substances
(acids, bases, solutions, etc.) and must therefore be cleaned before being returned.
When returning the instrument, use the original packaging or a suitable transport packaging.
Information on returns can be found under the heading “Service” on our local website.
10.3 Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an environmentally compatible way and in accordance with the country-specific waste disposal regulations.
48 WIKA operating instructions digital indicator, model DI35-D
11. Specifications
11. Specifications
Specifications
Digital indicator
Principle
Character size
Indication range
Display rate
Memory
Inputs
Inputs
Digital input
Input signals, version for panel mounting
Input signals, version in desktop case
Input configuration
7-segment LED, red, 5-digit, brightness adjustable in 10 gradations
14 mm
-9999 ... 99999
0.1 ... 10.0 seconds
EEPROM (parameter memory), data preservation > 100 years
2 x input for standard signals
< 2.4 V off, >10 V on, max. DC 30 V, Ri ≈ 5 kΩ
0 ... 20 mA, R i
4 ... 20 mA, R i
DC 0 ... 10 V, R i
≈ 50 Ω
≈ 50 Ω
≈ 150 kΩ
4 ... 20 mA, R i
≈ 50 Ω
Selectable via terminal connections and menu-driven programming
Accuracy
Temperature error
Measuring principle
Resolution
Measuring time
Transmitter power supply
Analogue output (option)
Number and type
Output signal
Error
Internal resistance
See the following tables “Accuracy/measuring errors of the input signals”
50 ppm/K, at ambient temperature T
U
T
U
> 40 °C
< 20 °C or
Sigma/delta
24 bit (with 1 second measuring time)
0.02 ... 10.0 s, with 1-channel measurement
0.04 ... 10.0 s, with 2-channel measurement
DC 24 V, max. 50 mA, galvanically isolated
1 analogue output (galvanically isolated)
4 ... 20 mA (12-bit), load ≤ 500 Ω
0 ... 20 mA (12-bit), load ≤ 500 Ω
DC 0 ... 10 V (12-bit), load ≥ 100 kΩ
0.1 % in the range 20 ... 40 °C
50 ppm/K outside temperature error
100 Ω (with measuring input DC 0 ... 10 V)
EN
WIKA operating instructions digital indicator, model DI35-D 49
11. Specifications
EN
Specifications
Switching output (option)
Number and type
Load capacity
Number of switching operations
2 or 4 switch contacts (relays), freely programmable
AC 250 V, 5 A (resistive load)
DC 30 V, 5 A (resistive load)
0.5 ∙105 at max. contact load
5 ∙ 106 mechanical
Isolation in accordance with DIN EN 50178
Parameters in accordance with DIN EN 60255
Voltage supply
Power supply
Power consumption
Electrical connection
See product label
Power supply galvanically isolated
AC 100 ... 240 V, 50/60 Hz, DC 100 ... 240 V
DC 10...40 V, AC 18 ... 30 V, 50/60 Hz
Overvoltage category II
Max. 15 VA
Removable plug-in terminal
Wire cross-section up to 2.5 mm²
Serial interface (option)
Interface
Protocol
Baud rate
Cable length
See product label
■
■
■
■
RS-232 (not galvanically isolated)
RS-232 (galvanically isolated)
RS-485 (not galvanically isolated, only for point-to-point connection)
RS-485 (galvanically isolated, only for point-to-point connection)
Manufacturer-specific ASCII
9,600 baud, no parity, 8 data bits, 1 stop bit
RS-232: max. 3 m
RS-485: max. 1,000 m
Case, panel mounting
Material
Ingress protection
Glass-fibre reinforced polycarbonate, black
Front: IP65, rear: IP00 (per IEC 60529)
Weight approx. 350 g
Recommended mounting grid 120 mm horizontal, 96 mm vertical
Mounting Sliding mounting elements, fixed via screws, for wall thicknesses up to 15 mm
50 WIKA operating instructions digital indicator, model DI35-D
11. Specifications
Specifications
Case, desktop case
Material
Ingress protection
Weight
Fuse
Front, rear, side plates: aluminium, black, powder-coated
Cover, base plate: hard paper, black (Pertinax)
IP40 (per IEC 60529) approx. 1.6 kg
Integrated fuse 0.5 A medium-acting (not to be changed by operator)
Operating conditions
Permissible ambient temperatures
Humidity
Requirements for the installation location
Operation: 0 ... 50 °C
Storage: -20 ... +80 °C
0 ... 75 % r. h. annual mean, without condensation
■
■
■
■
■
Pollution degree 2
No direct sunlight or proximity to hot objects
No mechanical vibration, mechanical shock (putting it down hard)
No soot, vapour, dust or corrosive gases
This is a class B instrument for emissions and is intended for use in industrial environments. In other environments, e.g. residential or commercial installations, it can interfere with other equipment under certain conditions. In such circumstances the operator is expected to take the appropriate measures.
EN
Accuracy/measuring errors of the input signals
Inputs with factory calibration
Input signals Measuring span
Current signals 0 ... 20 mA
4 ... 20 mA
Measuring error in
% of the measuring span 1)
≤ ±0.02 % ±1 digit
≤ ±0.02 % ±1 digit
Minimum measuring time
1-channel measurement
2-channel measurement
0.02 s
0.02 s
0.04 s
0.04 s
WIKA operating instructions digital indicator, model DI35-D 51
11. Specifications
EN
Input signals Measuring span
Measuring error in
% of the measuring span 1)
-
Minimum measuring time
1-channel measurement
2-channel measurement
Voltage signals DC 0 ... 18 mV
DC 0 ... 35 mV
DC 0 ... 75 mV
DC 0 ... 150 mV
DC 0 ... 300 mV
DC 0 ... 600 mV
≤ ±0.06 % ±1 digit
≤ ±0.06 % ±1 digit
≤ ±0.04 % ±1 digit
≤ ±0.03 % ±1 digit
≤ ±0.03 % ±1 digit
≤ ±0.03 % ±1 digit
DC 0 ... 1,250 mV ≤ ±0.03 % ±1 digit
DC 0 ... 2,500 mV ≤ ±0.03 % ±1 digit
DC 0 ... 5 V ≤ ±0.02 % ±1 digit
DC 0 ... 10 V ≤ ±0.01 % ±1 digit
Thermocouples
Type B, PtRh-PtRh
Type E, NiCr-CuNi
Type J, Fe-CuNi
-100 ... +1,810 °C ≤ ±0.10 % ±1 digit
-260 ... +1,000 °C ≤ ±0.06 % ±1 digit
-210 ... +1,200 °C ≤ ±0.05 % ±1 digit
Type K, NiCr-Ni
Type L, Fe-CuNi
Type N, NiCrSi-NiSI
Type R, PtRh-Pt
Type S, PtRh-Pt
Type T, Cu-CuNi
-250 ... +1,271 °C
-200 ... +900 °C
-250 ... +1,300 °C
0 ... 1,760 °C
0 ... 1,760 °C
-240 ... +400 °C
Resistance thermometer 2)
Pt100 (2-/4-wire) -200 ... +850 °C
≤ ±0.05 % ±1 digit
≤ ±0.06 % ±1 digit
≤ ±0.06 % ±1 digit
≤ ±0.07 % ±1 digit
≤ ±0.06 % ±1 digit
≤ ±0.07 % ±1 digit
≤ ±0.04 % ±1 digit
Pt100 (3-wire)
Pt200 (2-/4-wire)
Pt200 (3-wire)
Pt500 (2-/4-wire)
Pt500 (3-wire)
Pt1000 (2-/4-wire)
Pt1000 (3-wire)
-200 ... +850 °C
-200 ... +850 °C
-200 ... +850 °C
-200 ... +850 °C
-200 ... +850 °C
-200 ... +850 °C
-200 ... +850 °C
≤ ±0.04 % ±1 digit
≤ ±0.04 % ±1 digit
≤ ±0.04 % ±1 digit
≤ ±0.04 % ±1 digit
≤ ±0.04 % ±1 digit
≤ ±0.04 % ±1 digit
≤ ±0.04 % ±1 digit
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.02 s
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.04 s
1) The indication of the measuring error applies to ambient temperatures of 20 ... 40 °C and the measuring time of 1 s.
2) The indications for Pt100 3-/4-wire apply at a max. lead resistance of 10 Ω.
52 WIKA operating instructions digital indicator, model DI35-D
11. Specifications
Inputs for sensor calibration
Input signals Measuring span Measuring error in
% of the measuring span 1)
-
-
-
-
-
-
0.02 s
-
-
-
-
-
-
0.02 s
0.02 s
-
-
Minimum measuring time
1-channel measurement
2-channel measurement
-
Current signals
Voltage signals
Resistance (2-,
3-, or 4-wire)
0 ... 2 mA
0 ... 5 mA
0 ... 20 mA
4 ... 20 mA
DC -18 ... +18 mV
DC -35 ... +35 mV
DC -75 ... +75 mV
DC -150 ... +150 mV
DC -300 ... +300 mV
DC -500 ... +600 mV
≤ ±0.02 % ±1 digit
≤ ±0.02 % ±1 digit
≤ ±0.02 % ±1 digit
≤ ±0.02 % ±1 digit
≤ ±0.06 % ±1 digit
≤ ±0.06 % ±1 digit
≤ ±0.04 % ±1 digit
≤ ±0.03 % ±1 digit
≤ ±0.03 % ±1 digit
≤ ±0.03 % ±1 digit
DC -500 ... +1,250 mV ≤ ±0.03 % ±1 digit
DC -500 ... +2,500 mV ≤ ±0.03 % ±1 digit
DC -1 ... +5 V ≤ ±0.02 % ±1 digit
DC -1 ... +10 V
0 Ω ... 100 Ω
0 Ω ... 1 kΩ
0 Ω ... 10 kΩ
≤ ±0.01 % ±1 digit
≤ ±0.04 % ±1 digit
≤ ±0.04 % ±1 digit
≤ ±0.04 % ±1 digit
1) The indication of the measuring error applies to ambient temperatures of 20 ... 40 °C and the measuring time of 1 s.
-
-
-
-
-
-
0.04 s
-
-
-
-
-
-
0.04 s
0.04 s
EN
WIKA operating instructions digital indicator, model DI35-D 53
11. Specifications
Dimensions in mm
Panel mounting
EN
120
,0 including fixing attachments ließlic h Befe stigun g
3,0
DI35
Sealing ng
96,0
Inser mm e eins chli eßli ch A
139
,0 nsc hlus skle
Einb auti efe tion depth including connection terminal
Desktop case
(267 incl.
(267
displa
mm
inc l. An zeig
250 e un d A
250
,0 m nsc m sste cke r oh ne G ege nste cke r) y and coupler connectors without mating connector)
54
170
mm
WIKA operating instructions digital indicator, model DI35-D
Appendix 1: Overview of program numbers
Appendix 1: Overview of program numbers
Parameter PN Function
Measuring input 1
0 Measuring input
Factory setting
0
1
2
3
4
Full scale
Start value
Decimal places
Offset adjustment
Measuring input 2
5 Measuring input
6
7
8
9
Full scale
Start value
Decimal places
Offset adjustment
0 = N/A
Factory calibration
1 = DC 0 ... 10 V
2 = 0 ... 20 mA
3 = 4 ... 20 mA
Sensor calibration
4 = DC 0 ... 10 V
5 = 0 ... 20 mA
6 = 4 ... 20 mA
-9999 ... 99999
-9999 ... 99999
00000 ... 0.0000
-9999 ... 99999
0 = N/A
Factory calibration
1 = DC 0 ... 10 V
2 = 0 ... 20 mA
3 = 4 ... 20 mA
Sensor calibration
4 = DC 0 ... 10 V
5 = 0 ... 20 mA
6 = 4 ... 20 mA
-9999 ... 99999
-9999 ... 99999
00000 ... 0.0000
-9999 ... 99999
10000
0
00000
0
0
10000
0
00000
0
2
2
2
2
2
2
2
2
2
Authorisation level
2
EN
WIKA operating instructions digital indicator, model DI35-D 55
Appendix 1: Overview of program numbers
PN Function
General settings
10 Default display
EN
11 Switching of measuring inputs
13 Refresh rate
14 Measuring time
Parameter Factory setting
1 = Measuring input 1
2 = Measuring input 2
3 = Arithmetic function
0 = Key [▼] [▲] (triggered)
1 = Measuring input 1
(static)
2 = Measuring input 2
(static)
3 = Arithmetic function
(static)
4 = Multi-function key
(triggered)
5 = Cyclic (5 s)
6 = Cyclic (10 s)
7 = Cyclic (20 s)
0.1 ... 10.0 s
0.04 ... 10.0 s (two measuring inputs)
0.02 ... 10.0 s (one measuring input)
0 ... 9
3
0
1.0
0.2
3 19 Display brightness
Arithmetic function
15 Calculation type 3
16 Constant
17 Number of decimal places of constants
18 Number of decimal places of calculation
1 = Measuring input 1 ∙ constant
2 = Measuring input 2 ∙ constant
3 = Addition
4 = Subtraction
5 = Multiplication
6 = Ratio
7 = Percent
-9999 ... 99999
00000 ... 0.0000
00000 ... 0.0000
1
00000
00000
2
2
2
2
2
2
8
2
Authorisation level
2
56 WIKA operating instructions digital indicator, model DI35-D
Appendix 1: Overview of program numbers
PN Function
Analogue output (option)
20 Full scale
21 Start value
22 Reference value
23 Output signal
Interface
34 Interface properties
User authorisation
50 Locking code
51 Release code
52 Authorisation level
Special functions
53 Function of the digital input
54 Function of the multifunction key
55 TARE function
56 HOLD function
Parameter
-9999 ... 99999
-9999 ... 99999
0 = Deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Arithmetic function
0 = DC 0 ... 10 V
1 = 0 ... 20 mA
2 = 4 ... 20 mA
2
0 = Standard mode
1 = Transmission mode
0000 ... 9999
0000 ... 9999
0 ... 8
0
0 = Deactivated
1 = Switching the measuring input
2 = HOLD
3 = TARE
0 = Deactivated
1 = Switching the measuring input
2 = HOLD
3 = TARE
0 = Deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Measuring input 1 + 2
0 = Deactivated
1 = Triggered
2 = Static
0
0
0
0
0000
0000
8
Factory setting
10000
0
3
8
0
0
2
2
2
2
Authorisation level
4
4
2
2
2
EN
WIKA operating instructions digital indicator, model DI35-D 57
EN
Appendix 1: Overview of program numbers
PN Function
59 Flashing display
Switching output 1
60 Reference value
61 Switch point
62 Hysteresis
63 Switching function
64 Switching delay
65 Delay type
Switching output 2
70 Reference value
71 Switch point
72 Hysteresis
73 Switching function
74 Switching delay
75 Delay type
Parameter
0 = Deactivated
1 = at switch point 1
2 = at switch point 2
3 = at switch point 3
4 = at switch point 4
5 = at switch point 1 + 2
6 = at switch point 3 + 4
7 = at switch point 1 + 2 +
3 + 4
Factory setting
0
0 = Deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Arithmetic function
-9999 ... 99999
1 ... 99999
0 = Normally closed
1 = Normally open
0 ... 10.0 seconds
0 = none
1 = Switch-on delay
2 = Switch-off delay
3 = Switch-on and switchoff delay
1
1000
1
1
0.0
1
0 = Deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Arithmetic function
-9999 ... 99999
1 ... 99999
0 = Normally closed
1 = Normally open
0 ... 10.0 seconds
0 = none
1 = Switch-on delay
2 = Switch-off delay
3 = Switch-on and switchoff delay
1
1000
1
1
0.0
1
6
6
6
6
6
Authorisation level
6
6
6
6
6
6
6
6
58 WIKA operating instructions digital indicator, model DI35-D
Appendix 1: Overview of program numbers
PN Function
Switching output 3
80 Reference value
81 Switch point
82 Hysteresis
83 Switching function
84 Switching delay
85 Delay type
Switching output 4
90 Reference value
91 Switch point
92 Hysteresis
93 Switching function
94 Switching delay
95 Delay type
Parameter Factory setting
0 = Deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Arithmetic function
-9999 ... 99999
1 ... 99999
0 = Normally closed
1 = Normally open
0 ... 10.0 seconds
0 = none
1 = Switch-on delay
2 = Switch-off delay
3 = Switch-on and switchoff delay
1
1000
1
1
0.0
1
0 = Deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Arithmetic function
-9999 ... 99999
1 ... 99999
0 = Normally closed
1 = Normally open
0 ... 10.0 seconds
0 = none
1 = Switch-on delay
2 = Switch-off delay
3 = Switch-on and switchoff delay
1
1000
1
1
0.0
1
6
6
6
6
6
6
6
6
6
6
6
Authorisation level
6
EN
WIKA operating instructions digital indicator, model DI35-D 59
Appendix 1: Overview of program numbers
PN Function Parameter
EN
Linearisation
100 Number of interpolation points
Measuring input 1
101
...
130
Display value for interpolation point
Measuring input 1
140 Number of interpolation points
Measuring input 2
141
...
170
Display value for interpolation point
Measuring input 2
Serial number
200 Reading the serial number
0 ... 30
-9999 ... 99999
0 ... 30
-9999 ... 99999
0 ... 99999
Factory setting
0
Authorisation level
2
0
2
2
2
8
60 WIKA operating instructions digital indicator, model DI35-D
WIKA operating instructions digital indicator, model DI35-D 61
EN
EN
62 WIKA operating instructions digital indicator, model DI35-D
WIKA operating instructions digital indicator, model DI35-D 63
EN
64
WIKA Alexander Wiegand SE & Co. KG
Alexander-Wiegand-Straße 30
63911 Klingenberg • Germany
Tel. +49 9372 132-0
Fax +49 9372 132-406 [email protected]
www.wika.de
WIKA operating instructions digital indicator, model DI35-D
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 7 2.1 Overview, version for panel mounting
- 8 2.2 Overview, version in desktop case
- 9 2.3 Description
- 9 2.4 Scope of delivery
- 10 3.1 Explanation of symbols
- 11 3.2 Intended use
- 11 3.3 Improper use
- 12 3.4 Personnel qualification
- 13 3.5 Labelling, safety marks
- 14 4.1 Transport
- 14 4.2 Packaging and storage
- 15 5.1 Requirements for the installation location
- 15 5.2 Mounting, version for panel mounting
- 16 5.3 Mounting, version in desktop case
- 16 5.4 Electrical connection
- 16 5.4.1 Notes on installation
- 17 5.4.2 Pin assignment, version for panel mounting
- 18 5.4.3 Pin assignment, version in desktop case
- 19 5.5 Interface connector
- 19 5.6 Switching on the digital indicator
- 20 5.7 Connection examples, version for panel mounting
- 22 6.1 Key functions
- 22 6.2 Accessing and exiting programming mode
- 23 6.3 Navigating in the menu
- 23 6.4 Changing numerical values
- 23 6.5 Accessing or clearing MIN/MAX values
- 24 6.6 Switching display between measuring inputs
- 25 7.1 Setting measuring inputs
- 25 7.1.1 Input signal
- 26 7.1.2 Start and end value
- 27 7.1.3 Number of decimal places
- 27 7.1.4 Offset adjustment
- 27 7.2 General settings
- 27 7.2.1 Default display
- 28 7.2.2 Switching of measuring inputs
- 29 7.2.3 Refresh rate
- 29 7.2.4 Measuring time
- 29 7.2.5 Display brightness
- 29 7.3 Arithmetic function
- 30 7.4 Setting the analogue output (option)
- 30 7.4.1 Start and end value
- 31 7.4.2 Reference value
- 31 7.4.3 Output signal
- 31 7.4.4 Example
- 32 7.5 Setting the serial interface (option)
- 33 7.6 Setting user authorisations
- 33 7.6.1 Authorisation levels
- 33 7.6.2 Cancelling the password protection
- 34 7.7 Setting special functions
- 34 7.7.1 Function of the digital input
- 34 7.7.2 Function of the multi-function key
- 34 7.7.3 TARE function
- 35 7.7.4 HOLD function
- 36 7.8 Setting switching outputs
- 36 7.8.1 Flashing display on reaching the switch points
- 36 7.8.2 Reference value
- 37 7.8.3 Switch points
- 37 7.8.4 Switch behaviour
- 42 7.9 Linearising sensors
- 44 7.10 Reading the serial number
- 44 7.11 Restoring factory settings
- 47 9.1 Maintenance
- 47 9.2 Cleaning
- 48 10.1 Dismounting, version for control panel
- 48 10.2 Return
- 48 10.3 Disposal