- Sports & recreation
- Camping, tourism & outdoor
- Camping, tourism & outdoor cookware
- Cool boxes
- Electrolux
- RH448LD
- User manual
advertisement
▼
Scroll to page 2
of 16
MANUAL miniBar RH 436D RH 447D RH 430LD RH 440LD RH 441LD RH 455LD RH 456LD RH 460LD RH 461LD RH 456LDE English Type H20 / 60 821 2693 - 81 T.D. 07/02 TABLE OF CONTENTS 1.0 INTRODUCTION 3 2.0 FOR YOUR SAFETY 3 3.0 WARRANTY AND CUSTOMER SERVICE 3 4.0 INSTALLATION 4 4.8 4.9 8 9 5.0 2.1 2.2 4.1 4.2 4.3 4.4 4.5 4.6 4.7 Warnings and Safety Advice Coolants The Purpose of this Manual Tools/Materials Required Unpacking Cleaning Installation Securing Connecting the Device to the Electricity Supply Changing the Sliding Hinge Changing the Doorhang INSTRUCTION FOR USE 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 Initial Operation Temperature Control Automatic Defrost Function Ice-Making Automatic Door Control (ADC) Interior Light Environmental Advice Disposal Energy Saving Tips Declaration Check List Technical Data 2 3 3 4 4 4 4 5 6 7 10 10 10 10 10 11 12 13 13 13 13 14 15 1.0 INTRODUCTION You have made an excellent choice by choosing the Dometic miniBar. We are convinced that you will be satisfied with your new appliance in every way. Silent in operation, the miniBar fulfils high quality standards and guarantees an efficient use of resources and energy during its entire working life, i.e. during manufacturing, use and disposal. Please study the installation and operating instructions carefully before attempting to operate the miniBar. 2.0 2.1 FOR YOUR SAFETY Warnings and Safety Advice 2.2 3.0 In the interests of children's safety: When disposing of the refrigerator, remove all doors and leave the shelves inside. This prevents children from being accidentally trapped or suffocated in the refrigerator. Never open the cooling unit - it is under high pressure. Never store explosive substances, such as lighter fuel, petrol, ether or similar products in the miniBar. The minibar is not suitable for the proper storage of medications. The miniBar must be installed in such a way that accidental contact with the cooling unit (which heats up when in use) is impossible. The appliance has to be connected to a properly earthed socket in line with the relevant valid country regulations. Servicing must only be carried out by authorised service personnel. Coolants Ammonia is used as a coolant. This is a natural compound also used in household cleaning agents (1 litre of Salmiak cleaner contains up to 200g of ammonia - about twice as much as is used in the refrigerator). Sodium chromate is used for corrosion protection (less than 2% of the coolant). If a leak occurs (which can be easily detected due to the unpleasant smell): Switch the device off (pull mains plug, if applicable); Ventilate room thoroughly. Inform hotel personnel. For the safety of hotel guests and personnel, it has been established by inspectors that the coolant poses no threat to health. WARRANTY AND CUSTOMER SERVICE Warranty arrangements are in accordance with EC Directive 44/1999/CE and the normal conditions applicable for the country concerned. For warranty or other servicing, please contact our Dometic Service department. Any damage due to improper use is not covered by the warranty. The warranty does not cover any modifications to the appliance or the use of non-original Dometic parts; the warranty does not apply if the installation and operating instructions are not adhered to and no liability shall be entertained. Parts can be ordered throughout Europe from our Dometic Service department. When contacting customer service, please always state model, product, MLC-Code and serial number! You can find this information on the model label inside the device. e.g. 3 4.0 4.1 4.2 INSTALLATION The Purpose of this Manual The manual shows you how to: install the miniBar correctly. operate the miniBar correctly. guarantee the miniBar´s correct maintenance and functioning. deal with faults by yourself. Tools / Materials Required You will need the following tools for initial operation: mild detergent 4.3 Unpacking Check during unpacking that the device is defect-free. Report transport damage to the transport company within 48 hours. Check that the voltage noted on the model label corresponds to the mains voltage. Depending on the model, the following parts can be found in the miniBar : 2x 4.4 Cleaning Before operating the miniBar, we recommend you clean it both inside and outside. Use a soft cloth, lukewarm water and a mild detergent. Following this, wash out the miniBar using clean water and dry thoroughly. At annual intervals, remove dust from fridge aggregate using a brush or soft cloth. WARNING: To prevent material damage: Do not use soap or detergents which are harsh, coarse or which contain soda. Keep the door seal free from oil and grease. The cylinder locks have been lubricated in the factory to be long-lasting. 4 4.5 Installation IMPORTANT: Please follow the installation details below carefully. Guarantee is valid for products installed as described only. 1. The refrigerator must be level both directions 2. There sould be 20mm clearance to the wall 3. Ventilation must be provided as shown in alternatives A,B,C or D 4. The ventilation duct must at least measure 105mm x the wtdth of the refrigerator 5. Only the entire cooling unit must project into the duct as shown 6 Air passing through the duct must not be preheated by any source of heat 7. Ventilation grills, if used, must have openings of at least 200cm² each 5 4.6 4.6.1 Securing RH456LD/E 1. Tighten screw. 4.6.2 2. Put on cap. RH436D, RH447D, RH430LD, RH440LD, RH441LD, RH460LD, RH461LD The miniBar must be screwed onto the cupboard using the lower hinges. 1. Tighten screw. 2. Put on cap. 6 4.7 Connecting the Device to the Electricity Supply The device must be connected to a properly earthed socket in line with the relevant valid country regulations. Check prior to initial operation that the voltage noted on the model label corresponds to the mains voltage. If this is not the case, do not connect the device and contact your dealer! If the connection cable is damaged it must be replaced by the Customer Service at Dometic, or by respectively qualified personnel, in order to prevent any hazards. 4.7.1 Attention: For GB Only ! Plug connection (for United Kingdom only) If a 3-pin plug is used, it should be fitted with a 3 amp fuse, with other plug types, the circuit should contain a 5 amp fuse. Warning - This appliance must be earthed. IMPORTANT The wires in the mains lead of this appliance are coloured in accordance with the following code: GREEN and YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows. 1. Connect the GREEN and YELLOW coloured wire to the plug terminal marked letter E or earth symbol or coloured green or green and yellow. 2. Connect the BROWN coloured wire to the plug terminal marked letter L or coloured red. 3. Connect the BLUE coloured wire to the plug terminal marked letter N or coloured black. Moulded-On Plug Version The mains lead is fitted with a non-rewirable moulded-on plug containing a 3 amp fuse. If the fuse requires replacing at any time, the fuse cover/carrier should be removed using a small screwdriver to level out. The old fuse should be replaced by a 3 amp ASTA approved BS1362 fuse and the fuse cover/carrier must be refitted before the plug is used again. If the fuse cover-carrier is lost, a replaceement can be obtained from the Dometic service Shops. The fuse cover/carrier must be of the same colour as that of the coloured insert in the base of the plug. In no circumstances must the plug be used without a correct fuse cover/carrier fitted. ..... 7 If the plug supplied on the mains lead is not suitable for the socket in your home, it should be cut off and disposed of safely, or destroyed, to avoid any possible shock hazard resulting from the plug being inserted into a 13 amp socket elswhere in the use. A suitable replacement plug should then be fitted as given above. 4.8 Changing the Sliding Hinge (possible with RH430LD, RH440LD, RH441LD, RH460LD, RH436D, RH447D) 2. 1. 1. 2. 3. 4. Distance to cupboard door (A) 1. mm A 2. mm 1. When closed, the cupboard door (A) must not lie against the rest of the surrounding cupboard area (distance 1-2mm). 2. There must be a distance of 6-8mm between the cupboard door and the miniBar. 8 4.9 Changing the Doorhang ( RH436D, RH447D, RH430LD, RH440LD, RH441LD, RH460LD, RH461LD) L 1. R 2. 3. 2. 1. 4. 5. 6. 7. R L 1. 2. 8. 12. 9. 10. 13. 9 11. 5.0 5.1 INSTRUCTION FOR USE Initial Operation The device must be plugged into a properly earthed socket. The miniBar achieves its operating temperature after several hours. The miniBar operates silently ! 5.2 Temperature Control min. 5.3 max. The miniBar is fitted with an electronic temperature control. The thermostat control button is situated in the internal containers rear area. (RH455LD, RH456LD/E: the thermostat button is situated in the unrefrigerated compartment). Automatic Defrost Function The first defrosting phase commences 39 hours after the initial operation (5.1) and lasts for two hours. After this, the device operates for 22 hours at a time, followed by a defrosting period of 2 hours . T T T S S The ice layer must never be removed using force, nor must the defrosting process ever be accelerated using a heater. 5.4 Ice-Making only use drinking water! B A 1. 2. max. 3. 4. For Figure 3: In all miniBars, the ice tray (A) must be put on the left hand side of the vaporiser plate (B). An exception is model RH456LD. In this model, the ice tray must be placed on the right hand side of the vaporiser plate. Making the ice takes approximately 2-4 hours at an average ambient temperature of 25°C. 10 5.5 Automatic Door Control (ADC) The following descriptions only apply to devices with ADC. Using a red dot in the display window (A, point 3), the ADC shows that the miniBar´s door has been opened. 1. Open the miniBar, check its contents and - if applicable- stock it up again. 2. Close the miniBar. RH456LD/E All other models 2. 2. A A 1. 3. Insert ADC key and turn to the right. 1. 3. Insert ADC key and turn to the left. The red dot has disappeared now. 4. Remove ADC key. 5.5.1 Automatic Door Control (electrical) When the miniBar is opened, a magnetically operated approximation switch located underneath on the fridge is activated (FIG 1.) Depending on the connection (opening/closing mechanism), an electric circuit is closed or opened. Accordingly, this is registered and processed at the hotel reception. Note: Electrical rating! The miniBar´s wiring connection is situated at the rear of the appliance and consists of a 3-pin terminal strip (1). 1= terminal strip 2= approximation switch A= blue (opening mechanism) B= black (closing mechanism) C= white FIG.1 11 5.6 5.6.1 Interior Light RH456LD /E Model RH456LD/E is fitted with low voltage lighting. When the door is opened, the light in the cooling shelf is switched on via a sensor. The light in the uncooled storage shelf is switched on manually by means of a switch integrated into the lamp. Changing bulbs: 1. 2. 1. Pull out the mains plug. 2. Remove the reflector disk. 90° 3. Remove the defective bulb. 4. Insert new bulb. 5.Clip reflector disk back in. 5.6.2 Interior Light (All other models) When the door is opened, the light in the cooling shelf is switched on via a sensor. Changing bulbs: 1. Pull out the mains plug. 4. Insert new bulb. 2. Remove the reflector disk. 5. Clip reflector disk back in. To obtain spare bulbs, please contact your Dometic Service Centre. 12 3. Remove defective bulb. 5.7 5.8 Environmental Advice miniBars manufactured by Dometic GmbH are free from CFCs and fluorinated hydrocarbons. The cooling unit uses ammonia as the coolant (a natural compound of hydrogen and nitrogen). Cyclopentane, which does not damage the ozone layer, is used as propellant for the insulation made from PU-foam. Disposal In order to ensure the re-use of recyclable packaging materials, these must be disposed of using local collection systems. The device itself must be handed over to a disposal company or local council which will guarantee the correct use of recyclable materials and the proper disposal of the rest. Energy Saving Tips 5.9 5.10 At an average room temperature of approx. 22°C, it is sufficient to operate the miniBar with an average thermostat setting. If possible, always store pre-cooled goods. Do not expose the miniBar to direct sunlight and do not place it close to a source of heat. An unobstructed air circulation in the fridge aggregate must be ensured. When removing goods, only open the miniBar briefly. Switch on the miniBar approx. 12 hours prior to stocking. Declaration of conformity 13 5.11 Check List 1. Failure : No cooling (the aggregate at the back of the device is cold). Possible Cause Self Help a.) The thermostat is set to 0. a.) Set temperature control to middle position. b.) The device plug is not plugged in. b.) Plug in device plug. c.) No voltage in socket. c.) Check building fuse. Authorised Service d.) Defective electronics or sensor feelers. d.) Install new electronics or sensor. e.) Defective heating cartridge. e.) Install new heating cartridge. f.) The device is in its defrosting phase. f.) See operating instruction 5.3 2. Failure : No cooling (the aggregate is warm). Possible Cause Self Help a.) The device is not level. a.) Level the device using a spirit level. b.) The device was only switched on a short while ago. b.) Switch on the device and let it run for 5-6 hours. c.) Defective cooling aggregate. Authorised Service c.) Check whether repair is feasible. If not, exchange device. 3. Failure : Poor Cooling Performance. Possible Cause Self Help a.) The cooling aggregate is not sufficiently ventilated. a.) Check that the ventilation grids are not covered. Check that device has been installed properly (installation instruction 4.5). b.) The device is exposed to direct sunlight. b.) Follow installation instruction 4.5. c.) The fridge door does not close tightly. c.) Check installation in line 4.5. d.) Light permanently on when door closed. e.) The fridge was stocked a short while ago. e.) Check fridge after 5-6 hours for proper cooling function. Authorised Service c.) Is door magnet there? Install new door, if required. d.) Replace lighting sensor. Install new door, if required. 4. Failure : Frost formation in fridge. Possible Cause Self Help Authorised Service a.) The fridge door does not close tightly. a.) Check installation is in line with 4.5. a.) Is door magnet there? Install new door. 14 5.12 Technical Data Model RH430LD RH440LD Built-in Built-in RH441LD RH455LD Freestanding / Freestanding Built-in Casing Metal Metal Metal Wood (litres) 30 40 40 55 cooled / uncooled 30 / - 40 / - 40 / - 35 / 20 522x384x412 554x401x446 554x401x449 780x420x445 65 65 65 Gross Contentss Dimensions (mm) (H x W xD) Electrical Rating (W) 65 Power Consumption kWh / 24h* 0,7 0,8 0,8 0,8 Net Weight (kg) 11 14 15 26 Model RH456LDE RH456LD RH460LD RH461LD Built-in Freestanding Freestanding / Freestanding / Built-in Built-in Casing Metal Metal Metal Metal (litres) 56 56 60 60 cooled / uncooled 40 / 16 40 / 16 60 / - 60 / - 658x450x503 721x450x505 563x486x474 563x486x474 65 80 80 Gross Contents Dimensions (mm) (H x W x D) Electrical Rating (W) 65 Power Consumption kWh / 24h* 0,9 0,9 1,0 1,45 Net Weight (kg) 21 24,5 20 23 RH436D RH447D Freestanding / Freestanding / Built-in Built-in Metal Metal (litres) 30 40 cooled / uncooled 30 / - 40 / - 522x384x411 554x401x446 Model Casing Gross Contents Dimensions (mm) (H x W x D) Electrical Rating (W) 65 65 Power Consumption kWh/ 24h* 0,7 0,8 Net Weight (kg) 11 14 * Power consumption measured at an average ambient temperature of 25°C as an average annual value and at a cooling compartment temperature of 7°C in line with DIN/EN153. We reserve the right to make technical modifications to our products without notice! 15 Dometic GmbH In der Steinwiese 16 D-57074 Siegen Phone: +49-(0) 271 / 692 0 Fax: +49-(0) 271 / 692 300 www.dometic.de/minibar www.dometic.com © Dometic GmbH - 2002 - Subject to change without notice - Printed in Germany
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement