advertisement
▼
Scroll to page 2
of
38
KOBE Range Hoods CH00 Series Model No. Under Cabinet: CH0030SQB-1 (30”) CH0036SQB-1 (36”) CH0042SQB-1 (42”) CH0048SQB-1 (48”) Wall Mount: CH0030SQB-WM-1 (30”) CH0036SQB-WM-1 (36”) CH0042SQB-WM-1 (42”) CH0048SQB-WM-1 (48”) RA02 Series Model No. Wall Mount: RA0230SQB-1 / RA0230SQB-DC-1 (30”) RA0236SQB-1 / RA0236SQB-DC-1 (36”) RA0242SQB-1 / RA0242SQB-DC-1 (42”) RA0248SQB-1 / RA0248SQB-DC-1 (48”) RA0230SQB-DC24-1 (30”) RA0236SQB-DC24-1 (36”) RA0242SQB-DC24-1 (42”) RA0248SQB-DC24-1 (48”) RA0230SQB-DC48-1 (30”) RA0236SQB-DC48-1 (36”) RA0242SQB-DC48-1 (42”) RA0248SQB-DC48-1 (48”) INSTALLATION INSTRUCTIONS AND OPERATION MANUAL IMPORTANT READ THIS FIRST READ BEFORE INSTALLATION 1. Carefully check all contents of packages. 2. Thoroughly inspect the unit for any shipping damages, cosmetic damages or defects. 3. Have a certified contractor/electrician test the unit before installation. IF THERE IS ANY PROBLEM: 1. DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL. 2. Have your original invoice as proof of purchase and product serial number ready. 3. Contact your merchant for product replacement due to shipping damages, cosmetic damages or defects. 4. For all other issues, call 1-877-BUY-KOBE (289-5623), or e-mail to [email protected] . NO RETURN, NO REFUND, NO EXCHANGE IF: 1. PRODUCT HAS BEEN INSTALLED 2. KNOCK-OUT HOLES HAVE BEEN PUNCTURED 3. MISSING ORIGINAL PACKAGING MATERIAL AND/OR PARTS [ENGLISH] - READ AND SAVE THESE INSTRUCTIONS - CONTENTS IMPORTANT SAFETY INSTRUCTIONS ..................................................................................... 1 COMPONENTS OF PACKAGE................................................................................................... 3 INSTALLATION ........................................................................................................................... 5 OPERATION INSTRUCTIONS.................................................................................................. 15 MAINTENANCE ........................................................................................................................ 16 SPECIFICATIONS .................................................................................................................... 17 MEASUREMENTS & DIAGRAMS............................................................................................. 21 PARTS LIST.............................................................................................................................. 24 CIRCUIT DIAGRAM .................................................................................................................. 30 TROUBLE SHOOTING ............................................................................................................. 31 WARRANTY ............................................................................................................................. 32 PRODUCT REGISTRATION..................................................................................................... 34 - READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING ALL WIRING MUST BE DONE BY A PROFESSIONAL AND IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES. IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. 2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities. 3) Ducted fans must be vented to the outside. a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT SERVICE PANEL. b) Clean all grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly, make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, crawl spaces or garages. NOTE - This warranty is invalid without an authorized agent’s receipt or if unit is damaged due to misuse, poor installation, improper use, mistreatment, negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents. Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty. - KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood. WARNING: TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE TOP GREASE FIRE: 1. Keep all fan, baffle/spacer/filter/oil tunnel/oil container and grease-laden surfaces clean. Grease should not be allowed to accumulate on fan, baffle/spacer/filter/oil tunnel/oil container. 2. Always turn hood ON when cooking. 3. Use high settings on cooking range ONLY when necessary. 4. Do not leave cooking range unattended when cooking. 5. Always use cookware and utensils appropriate for the type and amount of food prepared. 6. Use this unit only in the manner intended by the manufacturer. 7. Before servicing, switch power off at service panel and lock service panel (if possible) to prevent power from switching on accidentally. 8. Clean ventilating fan frequently. 1 What to Do In The Event Of a Range Top Grease Fire • • • • SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. NEVER PICK UP A BURNING PAN – You May Get Burned. DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result. Use an extinguisher ONLY if: a) You have a Class A, B, C extinguisher and know how to operate it. b) The fire is small and contained in the area where it started. c) The fire department has been called. d) You can fight the fire with your back to an exit. What to Do If You Smell Gas - Extinguish any open flame. Do not try to turn on the lights or any type of appliance. Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company and Fire Department right away. CAUTION 1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors. 2) To reduce the risk of fire, use only metal ductwork. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) to prevent back drafting. 3) Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities. 4) Activating any switch on may cause ignition or an explosion. 5) Due to the size and weight of this hood, two people installation is recommended. ELECTRICAL SHOCK HAZARD – Can result in serious injury or death. Disconnect appliance from electric power before servicing. If equipped, the fluorescent light bulb contains small amounts of mercury, which must be recycled or disposed of according to Local, State, and Federal Codes. 2 COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) CH00 Series RANGE HOOD BOX {A} {B} {C} {D} {E} {F} {G} {H} {I} {J} {K} {L} KOBE Range Hood Warranty Registration Card Quick Reference Guide Oil Tunnel Baffle Filter – 2 (30” & 36”) – 3 (42” & 48”) Spacer x 2 6” Round Plastic Collar (30” & 36”) 8” Round Exhaust Plate (42” & 48”) Screws Package Hood-Mounting Bracket x 2 Screws Package Wire Cap x 3 Screws Package (for Under Cabinet only) {H} {I} {J} {K} {L} {A} Wire caps (3) {B} M4 x 3/4" (4 for 30” & 36”) M4 x 1-1/4” (8 for 42” & 48”) (4 for 30” & 36”) (8 for 42” & 48”) Duct Cover (Included in Wall Mound Hood ONLY) {C} Option Of: Model No. CH0030DC-12 for 30'' hood Duct Cover Screw Package for Duct Cover {D} Model No. CH0036DC-12 for 36'' hood Duct Cover Screw Package for Duct Cover {E} Model No. CH0042DC-12 for 42'' hood Duct Cover Screw Package for Duct Cover {F} Model No. CH0048DC-12 for 48'' hood Duct Cover Screw Package for Duct Cover {G} M4 x 1-1/2” (6) 3 RA02 Series RANGE HOOD BOX {A} {B} {C} {D} {E} {F} {G} {H} {I} {J} {K} {L} {M} KOBE Range Hood Warranty Registration Card Quick Reference Guide Oil Tunnel Baffle Filter x 2 (30” & 36”) x 3 (42” & 48”) Spacer 8” Round Exhaust Plate (42” & 48” only) Screws Package Hood-Mounting Bracket Screws Package Duct Cover (Model No. RA02DC-1) Wire Cap Screws Package {H} {I} {J} {K} {L} {A} Wire caps (3) {M} M4 x 1-1/2” (4) Inner Duct Extension RA02DC-24-1 {B} {C} (Included in RA02 SQB-DC24-1 and SQB-DC48-1) {N} {D} {O} {P} Inner Duct Extension (Model No. RA02DC-24-1) Duct Cover Mounting Bracket Screws Package {N} {O} {P} {E} M4 x 1-1/2” (2) Outer Duct Extension RA02DC-24 (Included in RA02 SQB-DC48-1 Only) {Q} {F} {G} Outer Duct Extension (Model No. RA02DC-24) {Q} - FOR MORE INFORMATION, PLEASE VISIT OUR W EBSITE www.koberangehoods.com OR CONTACT KOBE RANGE HOODS AT (626) 775-8880. 4 INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation Calculate the length of the installation, before installing the hood. (All calculation is measure in inches.) - FOR UNDER THE CABINET TABLE 1 CH00 Series A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood Bottom 30” & 36” Hood (Recommended 27” to 30”) 42” & 48” Hood (Recommended 30” to 36”) D = Height of Hood E = Height of the Cabinet - FOR STAND ALONE TABLE 2 CH00 Series A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood Bottom 30” & 36” Hood (Recommended 27” to 30”) 42” & 48” Hood (Recommended 30” to 36”) [(A – B] – (D + E)] D = Height of Hood E = Height of Duct Cover 5 RA02 Series SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR. CH00 SERIES – UNDER THE CABINET INSTALLATION ..................................................................7 CH00 SERIES – STAND ALONE INSTALLATION ..............................................................................9 RA02 SERIES – INSTALLATION ......................................................................................................12 6 CH00 SERIES – UNDER THE CABINET INSTALLATION Figure 1 Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. A straight, short venting run will allow the hood to perform more efficiently. Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood. Temporarily wire the hood to test for proper operation before installing. Important: Peel protective film off the hood (if any). For installing under the cabinet with recessed bottom, attach 4-inch wide wood filler strips (not included) on each side. Refer to Figure 2. Measure and create access opening for electrical wires under the cabinet. Figure 2 Hood Installation CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. Figure 3 1. Puncture the knockout holes on the hood as shown in Figure 3. 2. (This step only applies to 42” and 48” models.) Attach exhaust plate on hood with four (3/16” x 3/8”) screws (included). Shown in Figure 4. 3. Using references on Table 1 and measurements on page 21 center the hood in place beneath the cabinet and flush with the front of the cabinet. 4. Draw electrical wires through cabinet access opening. Refer to Figure 6. 5. From the bottom of the hood, place screw (provided) into the exact center of each knockout hole. Make sure all screws are in place before tightening screws. CAUTION: MAKE SURE THE HOOD IS SECURE BEFORE RELEASING. 6. For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure installation, use as many mounting holes as needed to secure from the inside of hood (screws included). Figure 4 7 Figure 5 Ductwork Installation 7. Use 6” round steel pipe for 30” and 36” models or 8” round steel pipe for 42” and 48” models (follow building codes in your area) to connect the exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 5. Wiring to Power Supply SAFETY WARNING Figure 6 RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY. 8. Connect the electrical wires. - Connect three wires (black, white and green) to house wires and cap with wire connectors. Connect according to color: black to black, white to white, and green to green as shown on Figure 6. - If necessary to hide the electrical wire connections, push wires back into the wiring box. Access the wire connections underneath the hood. To prevent any damage, make sure wires do not slip between motor or any moving parts. Figure 7 Install Accessories Figure 8 9. Attach Oil Tunnel. Refer to Figure 7. 10. Refer to Figure 8. Slide the baffle filter into the hood. Push the baffle filter upward. Slide forward. Pull downward. Fit into place. 11. Repeat until all baffle filters and spacers are resting against oil tunnel. Refer to page 22. Final Assembly 12. Turn power ON in control panel. Check all lights and fan operation. 13. Make sure to leave this manual for the homeowner. 8 CH00 SERIES – STAND ALONE INSTALLATION Model No. ***This installation required to have Duct Cover CH0030DC-12 / CH0036DC-12 / CH0042DC-12 / CH0048DC-12 Preparation before Installation Figure 9 NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. Refer to Figure 9. A straight, short venting run will allow the hood to perform more efficiently. Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood. Temporarily wire the hood to test for proper operation before installing. Important: Peel protective film off the hood and the duct cover (if any). If necessary, prepare back wall frame with cross framing lumber for secure installation. Using references on Table 2 and measurements on page 21-22, decide the level of the lumber. Refer to Figure 10. Figure 10 Preparation before Installation CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. Figure 11 1. (This step only applies to 42” and 48” models.) Attach exhaust plate on hood with four (3/16” x 3/8”) screws (included). Shown in Figure 11. 2. If necessary, remove the rubber stand on the back of the hood. 3. Use twelve (3/16” x 3/8”) screws (included) to attach the two hood-mounting brackets (included) to the top of the hood. 4. Using references in Table 2 and Measurements and Diagrams on pages 21-22, mark the leveling point of the hood. Position six mounting screws (included) on the wall, leaving 1/8” away from the wall. 9 5. Align hood-mounting bracket to the six screws on the wall and hook hood into place. Tighten screws to secure hood to the wall. 6. For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure installation, use as many mounting holes as needed to secure from the inside of hood (screws included). CAUTION: MAKE SURE HOOD SECURE BEFORE RELEASING. Figure 12 IS Wiring to Power Supply SAFETY WARNING RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY. 7. Connect the electrical wires. - Connect three wires (black, white and green) to house wires and cap with wire connectors. Connect according to color: black to black, white to white, and green to green as shown on Figure 12. - If necessary to hide the electrical wire connections, push wires back into the wiring box. Access the wire connections underneath the hood. To prevent any damage, make sure wires do not slip between motor or any moving parts. 10 Figure 13 Duct Cover Installation 8. Use 6” round steel pipe for 30” and 36” models or 8” round steel pipe for 42” and 48” models (follow building codes in your area) to connect the exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer Figure 13. Slide the duct cover onto the hood. 9. Use 3/16” x 3/8” screws (included) to attach duct cover to hood. Figure 14 Install Accessories 10. Attach oil tunnel. Refer to Figure 14. 11. Refer to Figure 15. Slide the baffle filter into the hood. Push the baffle filter upward. Slide forward. Pull downward. Fit into place. 12. Repeat until all baffle filters and spacers are resting against oil tunnel. Refer to page 22. Final Assembly 13. Turn power ON in control panel. Check all lights and fan operation. 14. Make sure to leave this manual for the homeowner. 11 Figure 15 RA02 SERIES - INSTALLATION Figure 16 Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. (Figure 16) A straight, short venting run will allow the hood to perform more efficiently. Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood. Temporarily wire the hood to test for proper operation before installing Important: Peel protective film off the hood and the duct cover (if any). If necessary, prepare back wall frame with cross framing lumber for secure installation. Refer to Table 2 and measurements on Page 23 to decide the level of the lumber. (Figure 17) Loosen hood-mounting brackets at the back of the hood, adjust brackets and tighten screws. If necessary, remove the rubber stand on the back of the hood. (Figure 18) Figure 17 Figure 18 12 Hood Installation Figure 19 CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. 1. Using references in Table 2 and measurements on Page 23, mark the leveling locations point for hood-mounting bracket on the wall. 2. Secure two mounting screws (provided) to the wall, leaving an 1/8” space from the wall. 3. Align the hood-mounting bracket to the mounting screws on the wall and hang hood into place. 4. Secure and tighten the mounting screws. Figure 20 CAUTION: MAKE SURE HOOD IS SECURE BEFORE RELEASING. Wiring to Power Supply SAFETY WARNING RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY. 5. Connect the electrical wires. - Connect three wires (black, white and green) to house wires and cap with wire connectors. Connect according to color: black to black, white to white, and green to green as shown on Figure 19. - If necessary to hide the electrical wire connections, push wires back into the wiring box. Access the wire connections underneath the hood. To prevent any damage, make sure wires do not slip between motor or any moving parts. 13 Figure 21 Figure 22 Duct Cover Installation 6. Use 6” round steel pipe for 30” and 36” models or 8” round steel pipe for 42” and 48” models (follow building codes in your area) to connect the exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer Figure 20. 7. Use four 4mm x 8mm screws (included) to attach duct cover to hood. Refer to Figure 21. Install Accessories 8. Attach oil tunnel. Refer to Figure 22. 9. Refer to Figure 23. Slide the baffle filter into the hood. Push the baffle filter upward. Slide forward. Pull downward. Fit into place. 10. Repeat until all baffle filters and spacers are resting against oil tunnel. Refer to page 23. Final Assembly 11. Turn power ON in control panel. Check all lights and fan operation. 12. Make sure to leave this manual for the homeowner. 14 Figure 23 OPERATION INSTRUCTIONS This KOBE hood is equipped with two rotary controls with powerful centrifugal squirrel cage, baffle filters, and bright LED lights. The two rotary controls are Light Control & Speed Control. Refer to Figure 28. Figure 28 Note: For best results, turn hood to QuietMode™ prior to preparation or cooking to establish airflow in the kitchen. Adjust speed as needed. • Rotate the Speed Control clockwise to cycle from QuietMode, Low, High, and off; and rotate counterclockwise to cycle from High, Low, QuietMode, and off • Rotate the Light Control clockwise to turn on the light. 15 MAINTENANCE For the optimal level of operation, clean the range hood surface and baffles regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve its fine appearance. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2. If hood looks splotchy (stainless steel hood), use an orange base cleaner to clean the surface of the hood. Avoid cleaner to get on the control switches. Only spread a light coating over the surface of the hood and leave on for a few minutes (do not leave on too long or this may cause damage to hood finish). Use soft towel to wipe off the cleaning solution, gently rubs any stubborn spots. Use a slightly damp towel to get rid of any cleaning solution. Use dry soft towel to dry the hood. 3. To bring the glow back into a stainless steel finish, use a stainless steel cleaner. 4. DO NOT allow deposits to remain for long periods of time. 5. DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust. 6. DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals, which may be harmful. Rinse with water after exposure and wipe dry with a clean cloth. To Clean Baffle Filters & Oil Tunnel CAUTION: DRAIN BAFFLE FILTERS AND OIL TUNNEL BEFORE OIL WILL OVERFLOW. 1. Remove the baffle filters and oil tunnel. 2. Using a sponge, wash with warm soapy water. Dry completely before returning into place. (Note: Baffle Filters are top rack dishwasher safe.) 16 SPECIFICATIONS CH00 Series MODEL / SIZE For Under Cabinet Application CH0030SQB-1 / 30” / Single Blower CH0036SQB-1 / 36" / Single Blower CH0042SQB-1 / 42” / Dual Blowers CH0048SQB-1 / 48” / Dual Blowers For Wall Mount Application CH0030SQB-WM-1 / 30” / Single Blower CH0036SQB-WM-1 / 36” / Single Blower CH0042SQB-WM-1 / 42” / Dual Blowers CH0048SQB-WM-1 / 48” / Dual Blowers COLOR Commercial Grade Stainless Steel CONSUMPTION / AMPERE CH0030SQB-1 and CH0030SQB-WM-1 – 320W CH0036SQB-1 and CH0036SQB-WM-1 – 320W CH0042SQB-1 and CH0042SQB-WM-1 – 350W CH0048SQB-1 and CH0048SQB-WM-1 – 350W VOLTAGE 120V 60Hz NUMBER OF BLOWER 1 (30” & 36”) 2 (42” & 48”) DESIGN 18-Gauge Seamless / Satin Finish FAN TYPE: CENTRIFUGAL Squirrel Cage EXHAUST Top 6” Round (30” & 36”) Top 8” Round (42” & 48”) CONTROLS Rotary Switch LIGHTS 3-Watt LED x 2 – 30”, 36” 3-Watt LED x 3 – 42”, 48” HOOD DIMENSION (W x D x H) CH0030SQB-1 and CH0030SQB-WM-1 CH0036SQB-1 and CH0036SQB-WM-1 CH0042SQB-1 and CH0042SQB-WM-1 CH0048SQB-1 and CH0048SQB-WM-1 OPTIONAL ACCESSORIES (W x D x H) 1) Duct Cover (Included in Wall Mount Hood) Model No. CH0030DC-12 (30” x 12” x 12”) Model No. CH0036DC-12 (36” x 12” x 12”) Model No. CH0042DC-12 (42” x 12” x 12”) Model No. CH0048DC-12 (48” x 12” x 12”) 2) Model No. SSP30 30” Stainless Steel Back Panel (30” x 1/10” x 32”) 3) Model No. SSP36 36” Stainless Steel Back Panel (36” x 1/10” x 32”) HOOD WEIGHT (lbs) CH0030SQB-1 CH0036SQB-1 CH0042SQB-1 CH0048SQB-1 17 Net 62 61 71 75 / 2.86A / 2.86A / 3A / 3A 29-3/4” x 24” x 18” 35-3/4” x 24” x 18” 41-3/4” x 24” x 18” 47-3/4” x 24” x 18” Gross 73 84 93 111 SPEED SINGLE BLOWER CH0030SQB-1 CH0036SQB-1 CH0030SQB-WM-1 CH0030SQB-WM-1 DUAL BLOWERS CH0042SQB-1 CH0048SQB-1 CH0042SQB-WM-1 CH0042SQB-WM-1 QuietMode Low High Air Capacity (cfm) Sone* 300 1.8 580 4.7 760 5.4 Air Capacity (cfm) Sone* 450 2.5 800 6.0 1200 8.0 *One sone is equivalent to the sound of a refrigerator at 40 decibels. **Specifications subject to change without notice. 18 RA02 Series MODEL / SIZE RA0230SQB-1 or RA0230SQB-DC-1 / 30” / Single Blower RA0236SQB-1 or RA0236SQB-DC-1 / 36” / Single Blower RA0242SQB-1 or RA0242SQB-DC-1 / 42” / Dual Blowers RA0248SQB-1 or RA0248SQB-DC-1 / 48” / Dual Blowers RA0230SQB-DC24-1 / 30” / Single Blower RA0236SQB-DC24-1 / 36” / Single Blower RA0242SQB-DC24-1 / 42” / Dual Blowers RA0248SQB-DC24-1 / 48” / Dual Blowers RA0230SQB-DC48-1 / 30” / Single Blower RA0236SQB-DC48-1 / 36” / Single Blower RA0242SQB-DC48-1 / 42” / Dual Blowers RA0248SQB-DC48-1 / 48” / Dual Blowers COLOR Commercial Grade Stainless Steel CONSUMPTION / AMPERE RA0230SQB-1 or RA0230SQB-DC-1 – 320W RA0236SQB-1 or RA0236SQB-DC-1 – 320W RA0242SQB-1 or RA0242SQB-DC-1 – 350W RA0248SQB-1 or RA0248SQB-DC-1 – 350W RA0230SQB-DC24-1 – 320W RA0236SQB-DC24-1 – 320W RA0242SQB-DC24-1 – 350W RA0248SQB-DC24-1 – 350W / 2.86A / 2.86A / 3A / 3A RA0230SQB-DC48-1 – 320W RA0236SQB-DC48-1 – 320W RA0242SQB-DC48-1 – 350W RA0248SQB-DC48-1 – 350W / 2.86A / 2.86A / 3A / 3A / 2.86A / 2.86A / 3A / 3A VOLTAGE 120V 60Hz NUMBER OF BLOWER 1 – 30”, 36” 2 – 42”, 48” DESIGN 18-Gauge Seamless / Satin Finish FAN TYPE: CENTRIFUGAL Squirrel Cage EXHAUST Top 6” Round – 30”, 36” Top 8” Round – 42”, 48” CONTROLS Rotary Switch LIGHTS 3-Watt LED x 2 – 30”, 36” 3-Watt LED x 3 – 42”, 48” HOOD DIMENSION (W x D x H) RA0230SQB-1 / RA0230SQB-DC24-1 / RA0230SQB-DC48-1 29-3/4” x 24” x 18” RA0236SQB-1 / RA0236SQB-DC24-1 / RA0236SQB-DC48-1 35-3/4” x 24” x 18” RA0242SQB-1 / RA0242SQB-DC24-1 / RA0242SQB-DC48-1 41-3/4” x 24” x 18” RA0248SQB-1 / RA0248SQB-DC24-1 / RA0248SQB-DC48-1 47-3/4” x 24” x 18” 19 DUCT COVER DIMENSION (W x D x H) RA02DC-1 (Original Duct Cover) RA02DC-24-1 (Extension Inner Duct Cover) RA02DC-24 (Extension Outer Duct Cover) OPTIONAL ACCESSORIES (W x D x H) 1) Model No. SSP30 30” Stainless Steel Back Panel (30” x 1/10” x 32”) 2) Model No. SSP36 36” Stainless Steel Back Panel (36” x 1/10” x 32”) HOOD WEIGHT (lbs) RA0230SQB-1 or RA0230SQB-DC-1 RA0236SQB-1 or RA0236SQB-DC-1 RA0242SQB-1 or RA0242SQB-DC-1 RA0248SQB-1 or RA0248SQB-DC-1 RA02DC-1 SPEED SINGLE BLOWER RA0230SQB-DC-1 RA0236SQB-DC-1 RA0230SQB-DC24-1 RA0236SQB-DC24-1 RA0230SQB-DC48-1 RA0236SQB-DC48-1 DUAL BLOWERS RA0242SQB-DC-1 RA0248SQB-DC-1 RA0242SQB-DC24-1 RA0248SQB-DC24-1 RA0242SQB-DC48-1 RA0248SQB-DC48-1 15” x 12” x 12” 15” x 12” x 24” 15” x 12” x 24” Net Gross 55 60 75 79 67 74 91 97 5 7 QuietMode Low High Air Capacity (cfm) Sone* 300 1.8 580 4.7 760 5.4 Air Capacity (cfm) Sone* 450 2.5 800 6.0 1200 8.0 *One sone is equivalent to the sound of a refrigerator at 40 decibels. **Specifications subject to change without notice. 20 MEASUREMENTS & DIAGRAMS *** All inch measurements are converted from millimeters. Inch measurements are estimated. *** All measurements in ( ) are millimeters. CH00 Series - FOR UNDER THE CABINET – MODEL NO.: CH0030SQB-1 (30”) CH0036SQB-1 (36”) CH0042SQB-1 (42”) CH0048SQB-1 (48”) - FOR STAND ALONE – MODEL NO.: CH0030SQB-WM-1 (30”) CH0036SQB-WM-1 (36”) CH0042SQB-WM-1 (42”) CH0048SQB-WM-1 (48”) 21 - FOR STAND ALONECH00 Series MODEL NO.: CH0030SQB-WM-1 (30”) CH0036SQB-WM-1 (36”) CH0042SQB-WM-1 (42”) CH0048SQB-WM-1 (48”) ***Hood-Mounting Bracket Baffle Filters & Stainless Steel Spacer 22 *** All inch measurements are converted from millimeters. Inch measurements are estimated. *** All measurements in ( ) are millimeters. RA02 Series MODEL NO.: RA0230SQB-1 or RA0230SQB-DC-1 (30”) RA0236SQB-1 or RA0236SQB-DC-1 (36”) RA0242SQB-1 or RA0242SQB-DC-1 (42”) RA0248SQB-1 or RA0248SQB-DC-1 (48”) Inner Duct Extension Model No.: RA02DC-24-1 *Included in RA02 SQB-DC24-1 and SQB-DC48-1 Series Outer Duct Extension Model No.: RA02DC-24 *Included in RA02 SQB-DC48-1 Series only 23 Baffle Filter for RA02 Series PARTS LIST CH00 Series MODEL NO.: CH0030SQB-1 and CH0030SQB-WM-1 (30”) CH0036SQB-1 and CH0036SQB-WM-1 (36”) CH0042SQB-1 and CH0042SQB-WM-1 (42”) CH0048SQB-1 and CH0048SQB-WM-1 (48”) NO. 1 2 DESCRIPTION Screw(3/16”x3/8”) 6” Round Plastic Exhaust 8” Round Exhaust Plate 3 Light Panel 4 Blower System 4A 5 Motor Support LED Light (3W) 6 7 8 9 10 11 12 13 14 Capacitor Panel Capacitor x 1PCS Capacitor x 2PCS LED Driver Valve Stem(LIGHT) Valve Stem(ON/OFF) Knob Metal Oil Tunnel Metal Oil Tunnel Metal Oil Tunnel Metal Oil Tunnel Baffle Filter Stainless Steel Spacer {1-5/16”( 33)x14-3/8”(365)} Stainless Steel Spacer {4-5/16”(109)x14-3/8”(365)} Stainless Steel Spacer {15/16”(23)x14-3/8”(365)} Stainless Steel Spacer {3-7/8” (98)x14-3/8”(365)} MODEL /SIZE CH0030SQB-1/CH0036SQB-1 CH0042SQB-1/CH0048SQB-1 CH0030SQB-1 CH0036SQB-1 CH0042SQB-1 CH0048SQB-1 CH0030SQB-1/CH0036SQB-1 CH0042SQB-1/CH0048SQB-1 CH0042SQB-1/CH0048SQB-1 CH0030SQB-1 CH0036SQB-1 CH0042SQB-1 CH0048SQB-1 CH0030SQB-1/CH0036SQB-1 CH0042SQB-1/CH0048SQB-1 CH0030SQB-1 CH0036SQB-1 CH0042SQB-1 CH0048SQB-1 CH0030SQB-1 CH0036SQB-1 CH0042SQB-1 CH0048SQB-1 PART NO. L1-0707-0002 L1-0505-0003 L1-0505-0004 B101-0030-06 B101-0036-06 B101-0042-06 B101-0048-06 L1-0302-0120-802RO L1-0302-0120-802RE L1-0233-0242 L1-0403-0301 L1-0201-0030 L1-0201-0036 L1-0201-0042 L1-0201-0048 L1-0401-0120-24 L1-0401-0120-24 L1-0402-D001 L1-0405-0404-B L1-0405-0402-B L1-0405-0400-A B101-9130-14A B101-9136-14A B101-9142-14A B101-9148-14A L1-0214-0191 B101-9130-15 B101-9136-15 B101-9142-15 B101-9148-15 Duct Cover (Included in CH00 SQB-WM-1 Series ONLY) NO. 01 02 DESCRIPTION Duct Cover MODEL /SIZE CH0030DC-12 PART NO. 12-0030DC-1 CH0036DC-12 12-0036DC-1 CH0042DC-12 12-0042DC-1 CH0048DC-12 12-0048DC-1 L1-0707-0002 Screw (3/16” x 3/8”) 24 CH00 Series Model No.: CH0030SQB-1 and CH0030SQB-WM-1 (30”) CH0036SQB-1 and CH0036SQB-WM-1 (36”) 25 CH00 Series Model No.: CH0042SQB-1 and CH0042SQB-WM-1 (42”) CH0048SQB-1 and CH0048SQB-WM-1 (48”) 26 PART LIST RA02 Series MODEL NO.: RA0230SQB-1 / RA0230SQB-DC24-1 / RA0230SQB-DC48-1(30”) RA0236SQB-1 / RA0236SQB-DC24-1 / RA0236SQB-DC48-1 (36”) RA0242SQB-1 / RA0242SQB-DC24-1 / RA0242SQB-DC48-1 (42”) RA0248SQB-1 / RA0248SQB-DC24-1 / RA0248SQB-DC48-1 (48”) NO. DESCRIPTION MODEL /SIZE PART NO. 6” Round Plastic Exhaust RA0230SQB-1/RA0236SQB-1 L1-0505-0003 8” Round Exhaust Plate RA0242SQB-1/RA0248SQB-1 L1-0505-0004 2 Duct Cover RA02DC 3 LED Light (3W) L1-0403-0301 4 Valve Stem(LIGHT) L1-0405-0404-B Valve Stem(ON/OFF) L1-0405-0402-B 1 4A 5 6 Knob 8 8A 9 10 L1-0405-0400-A Metal Oil Tunnel RA0230SQB-1 B101-9130-14A Metal Oil Tunnel RA0236SQB-1 B101-9136-14A Metal Oil Tunnel RA0242SQB-1 B101-9142-14A Metal Oil Tunnel 7 Light Panel Blower System RA0248SQB-1 B101-9148-14A RA0230SQB-1 B101-0230-06 RA0236SQB-1 B101-0236-06 RA0242SQB-1 B101-0242-06 RA0248SQB-1 B101-0248-06 RA0230SQB-1/RA0236SQB-1 L1-0302-0120-802RO RA0242SQB-1/RA0248SQB-1 L1-0302-0120-802RE Motor Support RA0242SQB-1/RA0248SQB-1 L1-0233-0242 Capacitor x 1PCS RA0230SQB-1/RA0236SQB-1 L1-0401-0120-24 Capacitor x 2PCS RA0242SQB-1/RA0248SQB-1 L1-0401-0120-24 LED Driver 11 Capacitor Panel 12 Baffle Filter L1-0402-D001 RA0230SQB-1 L1-0201-0230 RA0236SQB-1 L1-0201-0236 RA0242SQB-1 L1-0201-0242 RA0248SQB-1 13 12-0200-012-61 L1-0201-0248 L1-0214-0191 Stainless Steel Spacer {1-5/16”( 33)x14-3/8”(365)} RA0230SQB-1 B101-9130-15 Stainless Steel Spacer {4-5/16”(109)x14-3/8”(365)} RA0236SQB-1 B101-9136-15 Stainless Steel Spacer {15/16”(23)x14-3/8”(365)} RA0242SQB-1 B101-9142-15 Stainless Steel Spacer {3-7/8” (98)x14-3/8”(365)} RA0248SQB-1 B101-9148-15 27 RA02 Series Model No.: RA0230SQB-1 / RA0230SQB-DC24-1 / RA0230SQB-DC48-1 (30”) RA0236SQB-1 / RA0236SQB-DC24-1 / RA0236SQB-DC48-1 (36”) 28 RA02 Series Model No.: RA0242SQB-1 / RA0242SQB-DC24-1 / RA0242SQB-DC48-1 (42”) RA0248SQB-1 / RA0248SQB-DC24-1 / RA0248SQB-DC48-1 (48”) 29 CIRCUIT DIAGRAM MODEL NO.: CH0030SQB-1 and CH0030SQB-WM-1 (30”) CH0036SQB-1 and CH0036SQB-WM-1 (36”) RA0230SQB-1 / RA0230SQB-DC24-1 / RA0230SQB-DC48-1 (30”) RA0236SQB-1 / RA0236SQB-DC24-1 / RA0236SQB-DC48-1 (36”) MODEL NO.: CH0042SQB-1 and CH0042SQB-WM-1 (42”) CH0048SQB-1 and CH0048SQB-WM-1 (48”) RA0242SQB-1 / RA0242SQB-DC24-1 / RA0242SQB-DC48-1 (42”) RA0248SQB-1 / RA0248SQB-DC24-1 / RA0248SQB-DC48-1 (48”) 30 TROUBLE SHOOTING Issue After Installation, both motors and lights are not working. Lights are working, but motor(s) is not. Possible Cause The power is not on. Solution Make sure the circuit breaker and the unit’s power is ON. Use a voltage meter to check the power supply. The wire connection is not secure. Check and tighten wire connection. The control panel is defective. Replace the control panel. The motor(s) is defective. Replace the motor. The capacitor(s) is defective. Replace capacitor(s). The control panel is defective. Replace the control panel. The range hood is vibrating. The blower system is not secure. The motor is working, but the lights are not working. LED Light(s) is defective. The squirrel cage is not balanced. Hood is not secured in place. The light wiring(s) is loose. Light transformer is defective. The range hood is not venting out correctly. The control panel is defective. The range hood is installed outside of the manufacture recommended clearance. There is no make-up air inside the house. Obstacle blocking the pipe work. Cold air is coming into the home. The pipe size is smaller than the suggested pipe size. The pipe connection is not properly sealed. The damper is not properly installed or is missing from the installation. The damper is not installed. 31 Tighten the turbine impeller/squirrel cage and air chamber. Replace the squirrel cage. Check the installation of hood, tighten the mounting bracket. Replace the LED light. Check wire continuity from light transformer to LED light housing(s). Check power input and power output on the light transformer. If it’s needed, replace the light transformer. Replace the control panel. Adjust the clearance between the range hoods and cook top to 27” to 30”. For Island range hood, the clearance between the range hoods and cook top is 30” to 36”. Open the window to enhance the performance of the range hood by creating a sufficient make-up air. Remove all obstacles from the duct work. Change the ducting according to the manufacture suggestion. Check the pipe installation. Check the damper installation. By installing the damper, it will help to eliminate air backflow. WARRANTY WARRANTY CERTIFICATE In order to obtain warranty service, you must provide proof of original purchase from a KOBE authorized Dealer. Please keep a copy of your original invoice as proof of purchase. TWO-YEAR LIMITED LABOR WARRANTY ON KOBE PREMIUM SERIES: For two years from the date of your original invoice from a KOBE authorized dealer, we will repair any parts or components free of charge that failed due to manufacturing defects. KOBE reserves the right to replace, rather than repair the product free of charge at our sole discretion. It is your sole responsibility to ensure the product is readily accessible for the service technician to perform repairs. The service technician will not, under any circumstance, remove, alter or modify any fixture built around and/or connected to the product to gain access to perform repairs. TWO-YEAR LIMITED PARTS WARRANTY ON KOBE PREMIUM SERIES: For two years from the date of your original invoice from a KOBE authorized dealer, we will provide nonconsumable replacement parts or components free of charge that failed due to manufacturing defects. Consumable parts such as lights bulbs, filters, fuses, and oil cups are not covered by this warranty. WHAT IS COVERED: This warranty is valid in the United States and Canada. It is non-transferable and applies only to the original purchaser and does not extend to subsequent owner of this product. In Hawaii, Alaska and Canada, this warranty is limited. There may be additional shipping charges for parts and service technician travel costs in remote areas or locations 30 miles outside of KOBE authorized service area. WHAT IS NOT COVERED: 1. Normal wear and tear, regular service and maintenance required for the product. 2. Consumable parts such as light bulbs, filters, fuses, and oil cups. 3. Chips, scratches or dents due to abuse or misuse of the product, use of corrosive and abrasive cleaning products. 4. Damages caused by accident, fire, flood and other Acts of God. 5. Services in remote areas or locations 30 miles outside of KOBE authorized service area. 6. Labor cost incurred in connection with the removal of range hood, and reinstallation of replacement range hood, nor does it cover any other contingent expenses. 7. Scratches inside the hood, back of the baffle filter, and inside the duct cover. THIS WARRANTY WILL BE VOIDED WHEN: 1. Improper installation and failure to follow installation instructions. 2. Any repair, alteration, modification not authorized by KOBE. 3. Duct alteration, modification and connection. 4. Incorrect electric current, voltage or wiring. 5. Improper usage of the product such as commercially, outdoor or other usage other than its intended purpose which is residential indoor usage only. 32 6. Product is purchased from an unauthorized KOBE dealer. 7. Product is damaged due to negligence, misuse, abuse, accident. If we determine that the warranty exclusions listed above applies or if you fail to provide all necessary documentation for warranty service, you will be responsible for all expenses associated with the requested service, including parts, labor, shipping, travelling, and any other expense related to the service request. TO REQUEST WARRANTY SERVICE, PLEASE CONTACT KOBE RANGE HOODS SERVICE CENTER: From the 48 contiguous states: Toll Free: 1-877-BUY-KOBE (289-5623) E-Mail: [email protected] From Alaska, Hawaii, and Canada: TEL: 1-626-775-8880 E-Mail: [email protected] 33 WARRANTY INFORMATION FORM Fill in the blanks and keep this paper with the original invoice in a safe place for future service purpose. 1. Date of purchase : 2. Model No. : 3. Serial No. : For warranty service or spare parts purchase contact: KOBE Service Center (USA ONLY) Toll Free: 1-877-BUY-KOBE (289-5623) Email: [email protected] For service in Canada and to report a problem, please contact: Tel: 1-626-775-8880 Email: [email protected] Your notes: 34 KOBE Range Hoods 11775 Clark Street Arcadia, CA 91006 USA www.koberangehoods.com This KOBE hood is made for use in the USA and CANADA only. We do not recommend using this hood overseas as the power supply may not be compatible and may violate the electrical code of that country. Using a KOBE hood overseas is at your own risk and will void your warranty. Cette hotte KOBE est fabriquée pour usage aux États-Unis et au Canada seulement. Il n’est pas recommandé d’utiliser cette hotte à l’étranger puisque l’alimentation électrique pourrait ne pas être compatible et enfreindre le code de l’électricité de ce pays. L’usage de la hotte KOBE à l’étranger est à votre propre risque et la garantie sera annulée. Esta campana de extracción KOBE ha sido fabricada para ser utilizada únicamente en EE.UU. y CANADÁ. No recomendamos la utilización de esta campana en el extranjero debido a que la fuente de energía podría no ser compatible y podría violar el código eléctrico de dicho país. Utilizar una campana KOBE en el extranjero será a su propio riesgo y anulará la garantía. VER. 170301 Information subject to change without notice.
advertisement
Related manuals
advertisement