Residential & Light Commercial HVAC Ultra Quiet Series Electric Air Handler 11⁄2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz The Fedders multi-position air handlers, when matched with our air conditioners or heat pumps, offer a complete line of quiet, efficient split systems for today’s heating and cooling equipment. Easy To Install And Service Breaker accessible from front of unit when heater applied Performance External Access to heater circuit breakers pull / disconnects Dual rated 208/230 volt operation Provisions for field installed electrical connections from either side of air handler cabinet 1 1⁄2 to 5 tons External sweat refrigerant connections Built in filter rack TXV – factory installed standard, which precisely controls refrigerant distribution for improved comfort and cost savings Standard Features Pressure taps on suction and liquid line Corrosion resistant condensate drain pan. Primary and secondary drain Multiposition installation, upflow or horizontal left standard, horizontal right and downflow with minor modifications Optional Features 3-speed, permanently-lubricated PSC direct drive blower motor is resilient mounted for ultra quiet, vibration-free operation and flexible installation Field installed heater packages from 5 kW – 20 kW Foil faced insulation reduces noise and bacterial growth and features an easy to clean surface area 5-year limited parts warranty All indoor coils have copper tubing and aluminum fins Time Delay relay comes standard and allows for retro-fit installations 3/4" primary and secondary drains on all models Warranty Rated in Accordance with ARI Standard 210/240. Certification Applies Only When Used with Proper Components as Listed with ARI. Additional rating information can be found at www.aridirectory.org MODEL TONS REFRIGERANT AIR FLOW RANGE (CFM) DIMENSIONS H x W x D (in) RECOMMENDED FILTER SIZE H x W x D (in) SHIP/ OPERATIONS WEIGHT (lbs) AFPB24A1 1.5 - 2 R-22 625 – 900 43 3/8 x 18 x 22 16 x 20 x 1 115 / 109 AFPB24B1 1.5 - 2 R-22 615 – 880 43 3/8 x 18 x 22 16 x 20 x 1 120 / 113 AFPB36A1 2.5 - 3 R-22 950 – 1,260 43 3/8 x 18 x 22 16 x 20 x 1 120 / 113 AFPC48A1 3.5 - 4 R-22 1,190 – 1,590 48 3/8 x 22 x 26 20 x 25 x 1 161 / 152 AFPC48B1 4 R-22 1,195 – 1,590 48 3/8 x 22 x 26 20 x 25 x 1 167 / 160 AFPC60A1 5 R-22 1,340 – 1,895 48 3/8 x 22 x 26 20 x 25 x 1 167 / 160 AZFPC60B1 5 R-410A 1,340 – 1,895 48 3/8 x 22 x 26 20 x 25 x 1 167 / 160 Product Specifications PHYSICAL DATA MODEL NUMBER AFPB24A1 AFPB24B1 AFPB36A1 AFPC48A1 AFPC48B1 AFPC60A1 AZFPC60B1 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 MINIMUM CIRCUIT AMPACITY MCA (AMPS) 15 15 15 15 15 15 15 MAXIMUM OVERCURRENT PROTECTIVE DEVICE - MOCP (AMPS) 15 15 15 15 15 15 15 ELECTRIC DATA (208/230 VOLT, SINGLE PHASE, 60 Hz) VOLTAGE BLOWER FAN MOTOR TYPE PSC HP BLOWER DIMENSIONS 1/6 1/6 1/3 1/2 1/2 3/4 3/4 9x7 9x7 9 x 10 9x8 9x8 10 x 9 10 x 9 5.8 5.8 5.8 COIL DATA TYPE A-COIL COIL FACE AREA (ft 2) 4 4 4 O.D. ROWS / FPI 5.8 3/8" 2 - 14 3 - 14 3 - 14 3 - 12 4 - 12 3 - 12 4 - 12 LIQUID LINE CONNECTION SIZE (IN. OD) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 SUCTION LINE CONNECTION SIZE (IN. OD) 3/4 7/8 7/8 7/8 7/8 7/8 7/8 16 x 20 x 1 16 x 20 x 1 16 x 20 x 1 20 x 25 x 1 20 x 25 x 1 20 x 25 x 1 20 x 25 x 1 REFRIGERANT LINE CONNECTION FILTER DATA RECOMMENDED FILTER SIZE (H X W X D) (in) (FILTER NOT SUPPLIED) Clearance to Combustible Material Clearances from the air handler to the combustibles are zero inches from all sides, top, and bottom; one inch from discharge air plenum; and the duct within 36 inches of the plenum. 2 Specifications subject to change without notice. Product Specifications AIRFLOW PERFORMANCE MODEL NUMBER AFPB24A1 AFPB24B1 AFPB36A1 AFPC48A1 AFPC48B1 AFPC60A1 AZFPC60B1 MEASURED STATIC PRESSURE INLET TO OUTLET (INCHES WATER COLUMN) BLOWER SPEED 0.20 0.30 0.40 0.50 0.60 HIGH 925 900 850 795 690 MEDIUM 800 760 745 670 N/A LOW 655 625 600 N/A N/A HIGH 905 880 830 780 680 MEDIUM 785 735 730 655 N/A LOW 645 615 590 N/A N/A HIGH 1440 1350 1260 1180 1040 MEDIUM 1300 1220 1050 940 860 LOW 1160 1070 950 880 780 HIGH 1680 1640 1590 1520 1430 MEDIUM 1440 1410 1380 1340 1250 LOW 1240 1220 1190 1150 1100 HIGH 2230 2105 1990 1895 1725 MEDIUM 1950 1930 1840 1770 1590 LOW 1360 1360 1350 1340 1080 Specifications applicable to upflow and horizontal applications. Air flow shown at the following conditions: - No heat elements in Air Handler. Decrease CFM 2% for 5 kW, 7.5 kW or 10 kW heat kits. Decrease CFM 1% for 15 kW or 20 kW heat kits. - 60 Hertz – 230 volts. Decrease CFM 6% for 208 volt operations. - Dry coil airflow shown. 3 Specifications subject to change without notice. Accessories ELECTRIC HEATER KITS PART NUMBER DESCRIPTION USE WITH MODEL SIZE EEC05N1 5 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER ALL EEC05B1 5 KW, SINGLE PHASE, WITH CIRCUIT BREAKER ALL EEC07N1 7.5 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER ALL EEC07B1 7.5 KW, SINGLE PHASE, WITH CIRCUIT BREAKER ALL EEC10N1 10 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER ALL EEC10B1 10 KW, SINGLE PHASE, WITH CIRCUIT BREAKER ALL EEC15B1 15 KW, SINGLE PHASE, WITH CIRCUIT BREAKER AFPB36A1, AFPC48A1, AFPC48B1, AFPB60A1, AZFPB60B1 EEC20B1 20 KW, SINGLE PHASE, WITH CIRCUIT BREAKER AFPB36A1, AFPC48A1, AFPC48B1, AFPB60A1, AZFPB60B1 ELECTRIC HEAT - ELECTRICAL DATA SINGLE CIRCUIT SUPPLY kW 240 Phase VAC No. of Supply Circuits MBTUH 208/240 Heat Load Amps Min. Max. Wire À Fuse Á Ampacity Size Wire Size  Ground Size Á DUAL CIRCUIT SUPPLY Min. Wire Ampacity À Max. Fuse Size Á AWG MM2 AWG MM2 Ckt 1 Ckt 2 Ckt 1 Ckt 2 Wire Size  Ckt 1 Ckt 2 Ground Size  Ckt 1 Ckt 2 AWG / MM2 AWG / MM2 AWG / MM2 AWG / MM2 0 1 1 - - 5.0 15 14 2.1 14 2.1 - - - - - - - - 5* 1 1 14.8 / 17.1 20.9 30 30 10 5.3 10 5.3 - - - - - - - - 7.5* 1 1 22.1 / 25.6 31.3 43 50 8 8.4 10 5.3 - - - - - - - - 10* 1 1 29.5 / 34.1 41.7 57 60 6 13.3 10 5.3 - - - - - - - - 15* 1 1 or 2 44.3 / 51.2 62.5 83 90 4 21.2 8 8.4 57 26 60 30 6 / 13.3 10 / 5.3 10 / 5.3 10 / 5.3 20* 1 1 or 2 59.0 / 68.2 83.4 109 110 2 33.6 6 13.3 57 53 60 60 6 / 13.3 10 / 13.3 10 / 5.3 10 / 5.3 NOTES: *kW does not include motor watts. À Ampacities and over current protection based on largest air handler motor load. Refer to specific name plate for exact ampacity and overcurrent protection size. Minimum wire ampacity values are used for sizing field power conductors. Refer to the National Electrical Code (latest version), Article 310, for sizing conductors. NOTE: when more than three current-carrying conductors are in the same conduit, the conductor's ampacity must be derated. Á Maximum size fuse or HACR-type circuit breaker for field wiring protection.  Wire size based on 75°C copper wire with no more than three current-carrying conductors in the same conduit. All wiring must conform to the National Electrical Code and all local codes. 4 Specifications subject to change without notice. DIMENSIONS A I H F INLET WIDTH ACCESS COVER TO TXV B D E G PTH DE ET L IN C LOW VOLT CONNECTIONS LINE VOLTAGE KNOCKOUTS Product Specifications Specifications subject to change without notice. 5 Electric Air Handler Residential & Light Commercial Air Handler Model Number Identification R-22 Models A F P B 24 A 1 * A Product Type A = Air Handler Brand Motor Electrical Designation P = PSC 1 = 208 / 230 Volts, 1 Phase, 60 Hz 2 = 220 Volts, 1 Phase, 50 Hz 3 = 208 / 230 Volts, 3 Phase, 60 Hz 4 = 460 Volts, 3 Phase, 60 Hz 5 = 230 Volts, 3 Phase, 50 Hz 6 = 380 Volts, 3 Phase, 50 Hz Chassis Size B = 43 3/8"H x 18"W x 22"D C = 48 3/8"H x 22"W x 26"D Nominal BTUH 24 = 18,000/24,000 BTU/H (5.28 kW) / (7.03 kW) 36 = 30,000/36,000 BTU/H (8.79 kW) / (10.55 kW) 42 = 42,000 BTU/H (12.31 kW) 48 = 48,000 BTU/H (14.07 kW) 60 = 60,000 BTU/H (17.58 kW) Design Series A = A Series R-410A Models A Z F P C 60 B 1 * A Product Type Electrical Designation A = Air Handler 1 = 208 / 230 Volts, 1 Phase, 60 Hz 2 = 220 Volts, 1 Phase, 50 Hz 3 = 208 / 230 Volts, 3 Phase, 60 Hz 4 = 460 Volts, 3 Phase, 60 Hz 5 = 230 Volts, 3 Phase, 50 Hz 6 = 380 Volts, 3 Phase, 50 Hz 410A Refrigerant Brand Motor Design Series P = PSC A = A Series Nominal BTUH Chassis Size 24 = 18,000/24,000 BTU/H (5.28 kW) / (7.03 kW) 36 = 30,000/36,000 BTU/H (8.79 kW) / (10.55 kW) 42 = 42,000 BTU/H (12.31 kW) 48 = 48,000 BTU/H (14.07 kW) 60 = 60,000 BTU/H (17.58 kW) B = 43 3/8"H x 18"W x 22"D C = 48 3/8"H x 22"W x 26"D Fedders Corporation 505 Martinsville Rd. Liberty Corner, NJ 07938 USA (908) 604-8686 Form No. F-13AH All product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. Copyright ©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc. FD-015-0407-k 6 Specifications subject to change without notice.
advertisement