Residential & Light Commercial HVAC Split System Air Conditioner 11⁄2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz Performance: Efficiency rating of 13 SEER and 14 SEER Cooling capacities from 11⁄2 to 5 tons Refrigerant Circuit: Factory installed liquid line filter drier Long life copper tubes, aluminum fins State-of-the-art compressors Large, wrap-around coil surface Quality Built: Galvanized steel exterior cabinet with 1,000-hour salt spray, powder-coated finish Powder-coated fan guard Full louvered panel to protect coil Formed base with 21⁄2" ground clearance Limited 5-year warranty on parts Easy To Install: Factory-charged with R-22 refrigerant Only three screws to access electrical controls Easy access to service valves Rated in Accordance with ARI Standard 210. Certification Applies Only When Used with Proper Components as Listed with ARI. Additional rating information can be found at www.aridirectory.org Model Number C18ABD1VF C24ABD1VF C30ABD1VF C36ACD1VF C42ACD1VF C48ACD1VF C60ACD1VF Size (tons) Nominal BTUH Min. Circuit Ampacity Max. Fuse or Breaker Operating Dimensions H x W x D (inches) 1 1⁄2 2 2 1⁄2 18,000 24,000 9.1 11.5 15 15 30,000 36,000 20 42,000 48,000 14.3 18.7 20.3 23.1 60,000 30.1 50 26 1⁄2 X 21 1⁄2 X 21 1⁄2 26 1⁄2 X 21 1⁄2 X 21 1⁄2 32 1⁄2 X 21 1⁄2 X 21 1⁄2 32 1⁄2 X 29 1⁄2 X 29 1⁄2 32 1⁄2 X 29 1⁄2 X 29 1⁄2 32 1⁄2 X 29 1⁄2 X 29 1⁄2 39 X 29 1⁄2 X 29 1⁄2 3 3 1⁄2 4 5 30 35 40 Min. Mounting Ship / Operating Pad Size (inches) Weight (lbs) 24 24 24 32 32 32 32 x x x x x x x 24 24 24 32 32 32 32 144 / 138 142 / 136 169 / 163 189 / 180 213 / 204 217 / 208 230 / 220 Product Specifications PHYSICAL DATA MODEL SIZE 18 24 30 36 42 48 60 18,000 24,000 30,000 36,000 42,000 48,000 60,000 FAN MOTOR TYPE PSC PSC PSC PSC PSC PSC PSC HP 1/6 1/6 1/5 1/3 1/3 1/3 1/3 DIAMETER 18" 18" 18" 22" 22" 22" 24" 3 3 3 3 3 3 3 RPM 1,050 1,050 1,050 1,050 1,050 1,050 950 CFM 1,800 1,800 1,800 3,400 3,400 3,400 4,000 PERFORMANCE DATA NOMINAL CAPACITY (BTUH) FAN DATA BLADE OUTDOOR COIL TYPE Enhanced Aluminum Plate Fin / Rifled Copper Tube COIL FACE AREA (ft ) 9.5 9.5 12.2 18.2 18.2 18.2 22.2 O.D. 7mm 7mm 7mm 7mm 7mm 7mm 7mm FPI / ROWS 18 -2 18-2 18-2 18-1 18-2 18-2 18-3 2 ELECTRICAL DATA (208/230 – 1-60, VOLTAGE RANGE 197V - 253V) MINIMUM CIRCUIT AMPACITY - MCA (amps) 1 9.1 11.5 14.3 18.7 20.3 23.1 30.1 MAXIMUM OVERCURRENT PROTECTIVE DEVICE - MOCP (amps) 2 15 15 20 30 35 40 50 COMPRESSOR RLA (Rated Load Amps) 6.5 8.4 10.3 13.5 14.8 17 22.1 COMPRESSOR LRA (Locked Rotor Amps) 48 39 61 78 78 86 137 FAN MOTOR FLA (Full Load Amps) 1.0 1.0 1.4 1.8 1.8 1.8 1.9 LIQUID LINE CONNECTION SIZE (In. OD) 3/8 3/8 3/8 3/8 3/8 3/8 1/2 SUCTION LINE CONNECTION SIZE (In. OD) 3/4 3/4 7/8 7/8 7/8 7/8 1 1/8 RECOMMENDED LINE SET LIQUID TUBE DIAMETER (In. OD) 3/8 3/8 3/8 3/8 3/8 3/8 1/2 RECOMMENDED LINE SET SUCTION DIAMETER (In. OD) 3/4 3/4 7/8 7/8 7/8 7/8 1 1/8 FACTORY CHARGE R-22 - OZ. 72 106 91 87 128 150 204 REFRIGERANT CONNECTIONS NOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit. ALL motors/compressors contain internal overload protection. 1. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 2. Time delay fuses may be used in place of HACR circuit breaker. 2 Specifications subject to change without notice. Product Specifications ARI CERTIFIED COMBINATION PERFORMANCE RATINGS UNIT Outdoor Unit SIZE 18 Factory Supplied Enhancement AC1A024A Cooling Capacity (BTUH) SEER1 EER 12,750 13 11.3 17,500 12,750 13 11.3 TXV/TDR 18,000 13,500 14 12.0 AC1A024A TXV 21,600 15,750 13 11.3 AFPB24A1 TXV/TDR 21,600 15,750 13 11.3 AC1A042A + FV80A070-4 TXV/TDR 21,600 17,000 14 12.2 AC1A042A + FV80A085-4 TXV/TDR 21,600 17,000 14 12.2 AC1A030A TXV 26,600 19,500 13 11.4 AC1A036A TXV 26,600 19,500 13 11.4 AFPB36A1 TXV/TDR 26,600 19,500 13 11.4 AC1A060A + FV80A085-4 TXV/TDR 28,000 21,000 14 12.0 AC1A060A + FV80A115-5 TXV/TDR 28,000 21,000 14 12.0 AC1A036A TXV 34,000 24,750 13 11.4 AFPB36A1 TXV/TDR 34,000 24,750 13 11.4 AC1A060A + FV80A085-4 TXV/TDR 35,000 25,500 14 11.8 AC1A060A + FV80A115-4 TXV/TDR 35,000 25,500 14 11.8 AC1A042A TXV 40,000 29,250 13 11.5 AFPC48A1 TXV/TDR 40,000 29,250 13 11.5 AC1A060A + FV80A115-5 TXV/TDR 41,500 31,000 14 12.0 AC1A060A TXV 44,000 32,250 13 11.5 AFPC48A1 TXV/TDR 44,000 32,250 13 11.5 AC1A060A TXV 53,000 38,750 13 11.5 AFPC60A1 TXV/TDR 53,000 38,750 13 11.5 Total Sensible TXV 17,500 AFPB24A1 TXV/TDR AC1A036 + FV80A070-4 C18ABD1VF 24 Indoor Unit C24ABD1VF 30 C30ABD1VF 36 C36ACD1VF 42 C42ACD1VF 48 C48ACD1VF 60 C60ACD1VF 1. TDR required to obtain SEER rating Notes: a. Fedders coils include factory installed TXV. Fedders gas furnaces and air handlers contain the TDR as standard equipment. b. TDR kit available as accessory. Part Number TDR001A. c. Tested outdoor and indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. d. Above ratings based on 80ºF (27ºC) DB and 67ºF (19ºC) WB indoor entering air temperature and 95ºF (35ºC) DB air entering outdoor unit. EER SEER TDR TXV - Energy Efficiency Ratio Seasonal Energy Efficiency Ratio Time-Delay Relay Thermostatic Expansion Valve 3 Specifications subject to change without notice. Product Specifications LINE SET LENGTH AND SIZE BTUH SUCTION LINE SIZES LIQUID LINE SIZES 15 ft. 25 ft. 50 ft. 75 ft. 15 ft. 25 ft. 50 ft. 75 ft. 18 3/4" 3/4" 3/4" 3/4" 3/8" 3/8" 3/8" 3/8" 24 3/4" 3/4" 3/4" 3/4" 3/8" 3/8" 3/8" 3/8" 30 7/8" 7/8" 7/8" 7/8" 3/8" 3/8" 3/8" 3/8" 36 7/8" 7/8" 7/8" 7/8" 3/8" 3/8" 3/8" 3/8" 42 7/8" 7/8" 7/8" 1 1/8" 3/8" 3/8" 3/8" 3/8" 48 7/8" 7/8" 7/8" 1 1/8" 3/8" 3/8" 3/8" 3/8" 60 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1/2" 1/2" 1/2" 1/2" Recommended liquid and suction tube line size is for standard installations. The unit charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing length other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. These recommendations do not apply to Long Line Length Installations that exceed 75 feet or where there is more than 40 feet vertical separation between indoor and outdoor units. (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.) Note: See unit installation instructions for proper installation. EXTENDED COOLING CAPACITIES OUTDOOR UNIT MODEL INDOOR UNIT AC1A024A RATINGS AT STANDARD CONDITIONS CONDENSER ENTERING AIR TEMPERATURE DEGREES (F) BTUH SEER* CFM 80 85 90 95 100 105 110 115 TOTAL 19,100 18,550 18,025 17,500 16,800 16,150 15,550 14,850 17,500 13 650 SENSIBLE 13,900 13,550 13,150 12,750 12,250 11,800 11,300 10,850 TOTAL 19,700 19,100 18,600 18,000 17,400 16,900 16,300 15,800 SENSIBLE 14,300 14,000 13,800 13,500 13,200 12,900 12,500 12,100 TOTAL 23,700 22,900 22,150 21,600 20,700 19,950 19,150 18,400 SENSIBLE 17,300 16,750 16,200 15,750 15,100 14,550 14,000 13,500 TOTAL 24,000 23,200 22,400 21,600 20,600 19,800 19,000 18,200 SENSIBLE 17,900 17,600 17,300 17,000 16,600 16,300 16,000 15,700 TOTAL 29,150 28,300 27,500 26,600 25,650 24,750 23,850 23,000 SENSIBLE 21,300 20,750 20,100 19,500 18,750 18,100 17,500 16,800 TOTAL 31,000 30,000 29,000 28,000 27,000 26,000 25,000 24,200 SENSIBLE 22,200 21,800 21,400 21,000 20,600 20,200 19,800 19,400 TOTAL 37,000 36,200 35,150 34,000 32.900 31,800 30,700 29,650 SENSIBLE 27,000 26,450 25,650 24,750 24,000 23,250 22,500 21,650 TOTAL 39,000 37,600 36,400 35,000 34,000 33,000 31,800 30,600 SENSIBLE 27,200 26,600 26,200 25,500 25,000 24,600 24,200 23,600 TOTAL 43,450 42,300 41,150 40,000 38,800 37,650 36,550 35,500 SENSIBLE 31,750 30,850 30,100 29,250 28,350 27,500 26,700 25,950 TOTAL 47,650 46,400 45,250 44,000 42,700 41,550 40,330 39,200 SENSIBLE 34,750 33,850 33,100 32,250 31,200 30,500 29,400 28,650 TOTAL 56,600 55,400 54,150 53,000 51,800 50,600 49,500 48,600 SENSIBLE 41,250 40,500 39,550 38,750 37,850 36,950 36,150 35,500 C18ABD1VF AC1A036A + FV80A070-4 AC1A024A 18,000 21,600 14 13 640 810 C24ABD1VF AC1A042A + FV80A070-4 / AC1A042A + FV80A085-4 21,600 AC1A030A 26,600 14 13 810 1,000 C30ABD1VF AC1A060A + FV80A085-4 / AC1A060A + FV80A115-5 28,000 AC1A036A 34,000 14 13 1,000 1,150 C36ACD1VF C42ACD1VF C48ACD1VF C60ACD1VF AC1A060A + FV80A085-4 / AC1A060A + FV80A115-5 35,000 AC1A042A 40,000 AC1A048A AC1A060A 44,000 53,000 14 13 13 13 1,150 1,350 1,550 1,750 *TDR required to obtain SEER rating. 4 Specifications subject to change without notice. Specifications subject to change without notice. 5 21 1/2 21 1/2 21 1/2 29 1/2 29 1/2 29 1/2 29 1/2 C24ABD1VF C30ABD1VF C36ACD1VF C42ACD1VF C48ACD1VF C60ACD1VF A C18ABD1VF MODELS E VAPOR LINE CONNECTION D LIQUID LINE CONNECTION FIELD CONTROL SUPPLY CONNECTION 1/4" HOLE FIELD POWER SUPPLY CONNECTION 1 1/8" HOLE DIMENSIONS 39 32 1/2 32 1/2 32 1/2 32 1/2 26 1/2 26 1/2 B 29 1/2 29 1/2 1/2 3/8 3/8 3/8 29 1/2 29 1/2 3/8 3/8 3/8 D 21 1/2 21 1/2 21 1/2 C ALL DIMENSIONS AIR DISCHARGE A 1 1/8 7/8 7/8 7/8 7/8 3/4 3/4 E 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 F DIMENSIONS IN INCHES F B AIR IN 32 x 32 32 x 32 32 x 32 39 1⁄2 x 31 x 31 33 x 31 x 31 33 x 31 x 31 33 x 31 x 31 33 x 23 x 23 24 x 24 27 x 23 x 23 27 x 23 x 23 32 x 32 AIR IN SHIPPING DIMENSIONS HxWxD AIR DISCHARGE 24 x 24 24 x 24 MINIMUM MOUNTING PAD SIZE AIR IN (FRONT) C Product Specifications Product Specifications Residential & Light Commercial AC Condensing Units Model Number Identification C 24 A B D 1 VF*A Product Type C = Air Conditioner CH = Heat Pump Brand Nominal Capacity Fitting Type 18 = 18,000 BTUH [5.28 kW] 24 = 24,000 BTUH [7.03 kW] 30 = 30,000 BTUH [8.79 kW] 36 = 36,000 BTUH [10.55 kW] 42 = 42,000 BTUH [12.31 kW] 48 = 48,000 BTUH [14.07 kW] 60 = 60,000 BTUH [17.58 kW] V = Sweat Electrical Designation 1 = 208 / 230 Volts, 1 Phase, 60 Hz 2 = 220 Volts, 1 Phase, 50 Hz 3 = 208 / 230 Volts, 3 Phase, 60 Hz 4 = 460 Volts, 3 Phase, 60 Hz 5 = 230 Volts, 3 Phase, 50 Hz 6 = 380 Volts, 3 Phase, 50 Hz Series Chassis Size B = 211⁄2" W x 211⁄2" D x H - Determined by BTU Size C = 291⁄2" W x 291⁄2" D x H - Determined by BTU Size Fedders Corporation 505 Martinsville Rd. Liberty Corner, NJ 07938 (908) 604-8686 Form No. F-C13 Refrigerant Variations D = R-22 Refrigerant All product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. ©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc. FD-071 0507
advertisement
Related manuals
advertisement