Fedders Air Conditioner C30ABD1VF User manual

Add to My manuals
6 Pages

advertisement

Fedders Air Conditioner C30ABD1VF User manual | Manualzz
Residential & Light Commercial HVAC
Split System Air Conditioner
11⁄2 thru 5 Tons
208/230 Volt, 1-Phase, 60 Hz
Performance:
Efficiency rating of 13 SEER and 14 SEER
Cooling capacities from 11⁄2 to 5 tons
Refrigerant Circuit:
Factory installed liquid line filter drier
Long life copper tubes, aluminum fins
State-of-the-art compressors
Large, wrap-around coil surface
Quality Built:
Galvanized steel exterior cabinet with
1,000-hour salt spray, powder-coated finish
Powder-coated fan guard
Full louvered panel to protect coil
Formed base with 21⁄2" ground clearance
Limited 5-year warranty on parts
Easy To Install:
Factory-charged with R-22 refrigerant
Only three screws to access electrical controls
Easy access to service valves
Rated in Accordance with ARI Standard 210.
Certification Applies Only When Used with
Proper Components as Listed with ARI.
Additional rating information can be found
at www.aridirectory.org
Model
Number
C18ABD1VF
C24ABD1VF
C30ABD1VF
C36ACD1VF
C42ACD1VF
C48ACD1VF
C60ACD1VF
Size
(tons)
Nominal
BTUH
Min. Circuit
Ampacity
Max. Fuse or
Breaker
Operating Dimensions
H x W x D (inches)
1 1⁄2
2
2 1⁄2
18,000
24,000
9.1
11.5
15
15
30,000
36,000
20
42,000
48,000
14.3
18.7
20.3
23.1
60,000
30.1
50
26 1⁄2 X 21 1⁄2 X 21 1⁄2
26 1⁄2 X 21 1⁄2 X 21 1⁄2
32 1⁄2 X 21 1⁄2 X 21 1⁄2
32 1⁄2 X 29 1⁄2 X 29 1⁄2
32 1⁄2 X 29 1⁄2 X 29 1⁄2
32 1⁄2 X 29 1⁄2 X 29 1⁄2
39 X 29 1⁄2 X 29 1⁄2
3
3 1⁄2
4
5
30
35
40
Min. Mounting Ship / Operating
Pad Size (inches)
Weight (lbs)
24
24
24
32
32
32
32
x
x
x
x
x
x
x
24
24
24
32
32
32
32
144 / 138
142 / 136
169 / 163
189 / 180
213 / 204
217 / 208
230 / 220
Product Specifications
PHYSICAL DATA
MODEL SIZE
18
24
30
36
42
48
60
18,000
24,000
30,000
36,000
42,000
48,000
60,000
FAN MOTOR TYPE
PSC
PSC
PSC
PSC
PSC
PSC
PSC
HP
1/6
1/6
1/5
1/3
1/3
1/3
1/3
DIAMETER
18"
18"
18"
22"
22"
22"
24"
3
3
3
3
3
3
3
RPM
1,050
1,050
1,050
1,050
1,050
1,050
950
CFM
1,800
1,800
1,800
3,400
3,400
3,400
4,000
PERFORMANCE DATA
NOMINAL CAPACITY (BTUH)
FAN DATA
BLADE
OUTDOOR COIL
TYPE
Enhanced Aluminum Plate Fin / Rifled Copper Tube
COIL FACE AREA (ft )
9.5
9.5
12.2
18.2
18.2
18.2
22.2
O.D.
7mm
7mm
7mm
7mm
7mm
7mm
7mm
FPI / ROWS
18 -2
18-2
18-2
18-1
18-2
18-2
18-3
2
ELECTRICAL DATA (208/230 – 1-60, VOLTAGE RANGE 197V - 253V)
MINIMUM CIRCUIT AMPACITY - MCA (amps) 1
9.1
11.5
14.3
18.7
20.3
23.1
30.1
MAXIMUM OVERCURRENT PROTECTIVE DEVICE - MOCP (amps) 2
15
15
20
30
35
40
50
COMPRESSOR RLA (Rated Load Amps)
6.5
8.4
10.3
13.5
14.8
17
22.1
COMPRESSOR LRA (Locked Rotor Amps)
48
39
61
78
78
86
137
FAN MOTOR FLA (Full Load Amps)
1.0
1.0
1.4
1.8
1.8
1.8
1.9
LIQUID LINE CONNECTION SIZE (In. OD)
3/8
3/8
3/8
3/8
3/8
3/8
1/2
SUCTION LINE CONNECTION SIZE (In. OD)
3/4
3/4
7/8
7/8
7/8
7/8
1 1/8
RECOMMENDED LINE SET LIQUID TUBE DIAMETER (In. OD)
3/8
3/8
3/8
3/8
3/8
3/8
1/2
RECOMMENDED LINE SET SUCTION DIAMETER (In. OD)
3/4
3/4
7/8
7/8
7/8
7/8
1 1/8
FACTORY CHARGE R-22 - OZ.
72
106
91
87
128
150
204
REFRIGERANT CONNECTIONS
NOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from
service disconnect to unit. ALL motors/compressors contain internal overload protection.
1. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will
require larger wire sizes.
2. Time delay fuses may be used in place of HACR circuit breaker.
2
Specifications subject to change without notice.
Product Specifications
ARI CERTIFIED COMBINATION PERFORMANCE RATINGS
UNIT
Outdoor Unit
SIZE
18
Factory
Supplied
Enhancement
AC1A024A
Cooling Capacity (BTUH)
SEER1
EER
12,750
13
11.3
17,500
12,750
13
11.3
TXV/TDR
18,000
13,500
14
12.0
AC1A024A
TXV
21,600
15,750
13
11.3
AFPB24A1
TXV/TDR
21,600
15,750
13
11.3
AC1A042A + FV80A070-4
TXV/TDR
21,600
17,000
14
12.2
AC1A042A + FV80A085-4
TXV/TDR
21,600
17,000
14
12.2
AC1A030A
TXV
26,600
19,500
13
11.4
AC1A036A
TXV
26,600
19,500
13
11.4
AFPB36A1
TXV/TDR
26,600
19,500
13
11.4
AC1A060A + FV80A085-4
TXV/TDR
28,000
21,000
14
12.0
AC1A060A + FV80A115-5
TXV/TDR
28,000
21,000
14
12.0
AC1A036A
TXV
34,000
24,750
13
11.4
AFPB36A1
TXV/TDR
34,000
24,750
13
11.4
AC1A060A + FV80A085-4
TXV/TDR
35,000
25,500
14
11.8
AC1A060A + FV80A115-4
TXV/TDR
35,000
25,500
14
11.8
AC1A042A
TXV
40,000
29,250
13
11.5
AFPC48A1
TXV/TDR
40,000
29,250
13
11.5
AC1A060A + FV80A115-5
TXV/TDR
41,500
31,000
14
12.0
AC1A060A
TXV
44,000
32,250
13
11.5
AFPC48A1
TXV/TDR
44,000
32,250
13
11.5
AC1A060A
TXV
53,000
38,750
13
11.5
AFPC60A1
TXV/TDR
53,000
38,750
13
11.5
Total
Sensible
TXV
17,500
AFPB24A1
TXV/TDR
AC1A036 + FV80A070-4
C18ABD1VF
24
Indoor Unit
C24ABD1VF
30
C30ABD1VF
36
C36ACD1VF
42
C42ACD1VF
48
C48ACD1VF
60
C60ACD1VF
1. TDR required to obtain SEER rating
Notes:
a. Fedders coils include factory installed TXV. Fedders gas furnaces and air handlers
contain the TDR as standard equipment.
b. TDR kit available as accessory. Part Number TDR001A.
c. Tested outdoor and indoor combinations have been tested in accordance with
DOE test procedures for central air conditioners.
d. Above ratings based on 80ºF (27ºC) DB and 67ºF (19ºC) WB indoor entering
air temperature and 95ºF (35ºC) DB air entering outdoor unit.
EER
SEER
TDR
TXV
-
Energy Efficiency Ratio
Seasonal Energy Efficiency Ratio
Time-Delay Relay
Thermostatic Expansion Valve
3
Specifications subject to change without notice.
Product Specifications
LINE SET LENGTH AND SIZE
BTUH
SUCTION LINE SIZES
LIQUID LINE SIZES
15 ft.
25 ft.
50 ft.
75 ft.
15 ft.
25 ft.
50 ft.
75 ft.
18
3/4"
3/4"
3/4"
3/4"
3/8"
3/8"
3/8"
3/8"
24
3/4"
3/4"
3/4"
3/4"
3/8"
3/8"
3/8"
3/8"
30
7/8"
7/8"
7/8"
7/8"
3/8"
3/8"
3/8"
3/8"
36
7/8"
7/8"
7/8"
7/8"
3/8"
3/8"
3/8"
3/8"
42
7/8"
7/8"
7/8"
1 1/8"
3/8"
3/8"
3/8"
3/8"
48
7/8"
7/8"
7/8"
1 1/8"
3/8"
3/8"
3/8"
3/8"
60
1 1/8"
1 1/8"
1 1/8"
1 1/8"
1/2"
1/2"
1/2"
1/2"
Recommended liquid and suction tube line size is for standard installations. The unit charge is correct for the outdoor unit, matched indoor coil and
15 feet of refrigerant tubing. For tubing length other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied
by the per foot value. These recommendations do not apply to Long Line Length Installations that exceed 75 feet or where there is more than 40 feet
vertical separation between indoor and outdoor units. (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.)
Note: See unit installation instructions for proper installation.
EXTENDED COOLING CAPACITIES
OUTDOOR
UNIT MODEL
INDOOR UNIT
AC1A024A
RATINGS AT
STANDARD CONDITIONS
CONDENSER ENTERING AIR TEMPERATURE DEGREES (F)
BTUH
SEER*
CFM
80
85
90
95
100
105
110
115
TOTAL
19,100
18,550
18,025
17,500
16,800
16,150
15,550
14,850
17,500
13
650
SENSIBLE
13,900
13,550
13,150
12,750
12,250
11,800
11,300
10,850
TOTAL
19,700
19,100
18,600
18,000
17,400
16,900
16,300
15,800
SENSIBLE
14,300
14,000
13,800
13,500
13,200
12,900
12,500
12,100
TOTAL
23,700
22,900
22,150
21,600
20,700
19,950
19,150
18,400
SENSIBLE
17,300
16,750
16,200
15,750
15,100
14,550
14,000
13,500
TOTAL
24,000
23,200
22,400
21,600
20,600
19,800
19,000
18,200
SENSIBLE
17,900
17,600
17,300
17,000
16,600
16,300
16,000
15,700
TOTAL
29,150
28,300
27,500
26,600
25,650
24,750
23,850
23,000
SENSIBLE
21,300
20,750
20,100
19,500
18,750
18,100
17,500
16,800
TOTAL
31,000
30,000
29,000
28,000
27,000
26,000
25,000
24,200
SENSIBLE
22,200
21,800
21,400
21,000
20,600
20,200
19,800
19,400
TOTAL
37,000
36,200
35,150
34,000
32.900
31,800
30,700
29,650
SENSIBLE
27,000
26,450
25,650
24,750
24,000
23,250
22,500
21,650
TOTAL
39,000
37,600
36,400
35,000
34,000
33,000
31,800
30,600
SENSIBLE
27,200
26,600
26,200
25,500
25,000
24,600
24,200
23,600
TOTAL
43,450
42,300
41,150
40,000
38,800
37,650
36,550
35,500
SENSIBLE
31,750
30,850
30,100
29,250
28,350
27,500
26,700
25,950
TOTAL
47,650
46,400
45,250
44,000
42,700
41,550
40,330
39,200
SENSIBLE
34,750
33,850
33,100
32,250
31,200
30,500
29,400
28,650
TOTAL
56,600
55,400
54,150
53,000
51,800
50,600
49,500
48,600
SENSIBLE
41,250
40,500
39,550
38,750
37,850
36,950
36,150
35,500
C18ABD1VF
AC1A036A + FV80A070-4
AC1A024A
18,000
21,600
14
13
640
810
C24ABD1VF
AC1A042A + FV80A070-4 /
AC1A042A + FV80A085-4
21,600
AC1A030A
26,600
14
13
810
1,000
C30ABD1VF
AC1A060A + FV80A085-4 /
AC1A060A + FV80A115-5
28,000
AC1A036A
34,000
14
13
1,000
1,150
C36ACD1VF
C42ACD1VF
C48ACD1VF
C60ACD1VF
AC1A060A + FV80A085-4 /
AC1A060A + FV80A115-5
35,000
AC1A042A
40,000
AC1A048A
AC1A060A
44,000
53,000
14
13
13
13
1,150
1,350
1,550
1,750
*TDR required to obtain SEER rating.
4
Specifications subject to change without notice.
Specifications subject to change without notice.
5
21 1/2
21 1/2
21 1/2
29 1/2
29 1/2
29 1/2
29 1/2
C24ABD1VF
C30ABD1VF
C36ACD1VF
C42ACD1VF
C48ACD1VF
C60ACD1VF
A
C18ABD1VF
MODELS
E
VAPOR LINE
CONNECTION
D
LIQUID LINE
CONNECTION
FIELD CONTROL
SUPPLY CONNECTION
1/4" HOLE
FIELD POWER
SUPPLY CONNECTION
1 1/8" HOLE
DIMENSIONS
39
32 1/2
32 1/2
32 1/2
32 1/2
26 1/2
26 1/2
B
29 1/2
29 1/2
1/2
3/8
3/8
3/8
29 1/2
29 1/2
3/8
3/8
3/8
D
21 1/2
21 1/2
21 1/2
C
ALL DIMENSIONS
AIR DISCHARGE
A
1 1/8
7/8
7/8
7/8
7/8
3/4
3/4
E
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
2 1/2
F
DIMENSIONS IN INCHES
F
B
AIR IN
32 x 32
32 x 32
32 x 32
39 1⁄2 x 31 x 31
33 x 31 x 31
33 x 31 x 31
33 x 31 x 31
33 x 23 x 23
24 x 24
27 x 23 x 23
27 x 23 x 23
32 x 32
AIR IN
SHIPPING DIMENSIONS
HxWxD
AIR DISCHARGE
24 x 24
24 x 24
MINIMUM
MOUNTING
PAD SIZE
AIR IN
(FRONT)
C
Product Specifications
Product Specifications
Residential & Light Commercial
AC Condensing Units
Model Number Identification
C 24 A B D 1
VF*A
Product Type
C = Air Conditioner
CH = Heat Pump
Brand
Nominal Capacity
Fitting Type
18 = 18,000 BTUH [5.28 kW]
24 = 24,000 BTUH [7.03 kW]
30 = 30,000 BTUH [8.79 kW]
36 = 36,000 BTUH [10.55 kW]
42 = 42,000 BTUH [12.31 kW]
48 = 48,000 BTUH [14.07 kW]
60 = 60,000 BTUH [17.58 kW]
V = Sweat
Electrical Designation
1 = 208 / 230 Volts, 1 Phase, 60 Hz
2 = 220 Volts, 1 Phase, 50 Hz
3 = 208 / 230 Volts, 3 Phase, 60 Hz
4 = 460 Volts, 3 Phase, 60 Hz
5 = 230 Volts, 3 Phase, 50 Hz
6 = 380 Volts, 3 Phase, 50 Hz
Series
Chassis Size
B = 211⁄2" W x 211⁄2" D x H - Determined by BTU Size
C = 291⁄2" W x 291⁄2" D x H - Determined by BTU Size
Fedders Corporation
505 Martinsville Rd.
Liberty Corner, NJ 07938
(908) 604-8686
Form No. F-C13
Refrigerant Variations
D = R-22 Refrigerant
All product specifications reflect available information at the printing of this brochure.
Fedders reserves the right to revise or modify products and/or specifications without notice.
©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc.
FD-071 0507