C S -E 9D K R W
C U -E 9D K R / C S -E 1 2 D K R W
C U -E 1 2 D K R
9 Oper ating Instr uctions
Thank you for purchasing Panasonic Air Conditioner
Definition
To prevent personal injury,
injury to others and property
damage, the following
instructions must be
followed.
Incorrect operation due to
failure to follow instructions
will cause harm or damage,
the seriousness of which is
classified as below:
SAFETY PRECAUTIONS
Installation Precautions
Warning
Do not install, remove and reinstall the unit by yourself.
• Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or
specialist for the installation work.
Caution
Warning
This sign warns of death
or serious injury.
Caution
•
•
•
This air conditioner must be earthed. Improper grounding will cause electric shock.
Ensure that the drainage piping is connected properly. Otherwise, water will leak.
Current leakage protection equipment must be installed. Otherwise, electric shock or fire may
occur.
•
Do not install the unit in a potentially explosive atmosphere.
Operation Precautions
This sign warns of injury
or damage to property.
The instructions to be
followed are classified by
the following symbols:
Warning
•
•
•
•
•
•
This symbol denotes
an action that is
PROHIBITED.
These symbols denote
actions that are
COMPULSORY.
•
•
Do not share power outlet.
Do not modify power cord.
Do not use an extension cord.
Do not operate with wet hands.
Do not insert finger or other objects into the
indoor or outdoor unit.
Do not attempt to repair the unit by
yourself.
Do not use rechargeable (Ni-Cd) batteries.
Keep the remote control away from infants
and small children to prevent them from
accidentally swallowing the batteries.
•
•
•
In case of emergency or abnormal
condition (burnt, smell, etc) occurs, turn
off the power supply.
Do not wash the unit with water, benzene,
thinner or scouring powder.
Do not use for other purposes such as
preservation of food.
Do not use any combustible equipment at
airflow direction.
Do not sit or place anything on the indoor
or outdoor unit.
Do not expose directly to cold air for a
long period.
•
•
Ventilate the room regularly.
Pay attention as to whether the
installation rack is damaged after long
period of usage.
•
Switch off the power supply before
cleaning or servicing.
Turn off the power supply if the unit is not
used for a long period of time.
•
•
Use specified supply cord.
If the supply cord is damaged or needed
to be replaced, it must be replaced by
the manufacturer or its service agent or
a similarly qualified person in order to
avoid a hazard.
Remove the batteries if the unit is not
going to be use for a long period of time.
New batteries of the same type must be
inserted following the polarity stated to
prevent malfunction of the remote control.
Caution
•
•
•
•
•
•
Operation Condition (OC)
Safety Regulation
Use this air conditioner under the following temperature
range.
The appliance is not intended for use by young children or infirm
person without supervision. Young children should be supervised to
ensure that they do not play with the appliance.
44
DBT: Dry Bulb Temperature
WBT: Wet Bulb Temperature
Indoor
Outdoor
DBT WBT DBT WBT
Maximum Temperature (COOL)
32
23
43
26
Maximum Temperature (HEAT)
30
–
24
18
Minimum Temperature (COOL)
16
11
16
11
Minimum Temperature (HEAT)
16
–
-5
-6
CS-E9DKRW CU-E9DKR / CS-E12DKRW CU-E12DKR
Note:
The illustrations in this manual are for explanation purposes only and may differ from the
actual unit. It is subjected to change without notice for future improvement.
PRODUCT OVERVIEW
About
Remote Control Preparation
Air intake
Indoor Unit
Supersonic air
purifying device
Front panel
2. Insert
batteries
(AAA or
R03)
1. Pull out
Auto OFF/ON
button
Air filter
3. Press CLOCK button
POWER TIMER QUIET POWERFUL ION
Receiver
4. Set
current
time
Airflow direction louver
5. Press again to confirm
Discharged air
Ionizer
Do not touch
during operation
Outdoor Unit
• Timer operation will be based on
current time set.
Indicator
POWER TIMER QUIET POWERFUL ION
SUPER
ALLERU-BUSTER
Air inlet (rear)
Air inlet (side)
• The batteries can be used for
approximately 1 year.
• The batteries must be
recycled or disposed of
properly.
Remote Control Signal
• Make sure it is not obstructed.
• Maximum distances: 10m.
Air outlet
Remote Control
Transmitter
• Certain fluorescent lights may
interfere with signal transmission.
Consult your dealer.
Auto OFF/ON Button
• To operate the unit if the
remote control is misplaced or
malfunctioning.
LCD display
Ion operation
Operation mode
Airflow direction
adjustment
Memory reset
Action
Operation
mode
Press once
Automatic
Operation
Press until “beep”
sound and release.
Cooling
Operation
Temperature setting
Off/On
Quiet operation
Powerful operation
Fan speed selection
Press until “beep”
sound and release.
Timer setting
Press again until
“beep-beep”sound
and release.
Clock setting
Check
Heating
Operation
• To OFF, press again the Auto OFF/
ON button.
Troubleshooting
Operation delayed for few minutes after restart.
This is a normal self protection control.
Sound like water flowing during operation.
Caused by refrigerant flow inside.
Mist emerges from indoor unit.
Condensation effect due to cooling process.
Noisy during operations.
Installation work could be slanted or front panel didn’
t close properly.
Remote control/display does not work.
Check whether batteries are correctly inserted or need replacement.
The unit cannot operate.
Check either circuit breaker is tripped or timer is used correctly.
Outdoor unit emits water/steam.
Condensation or evaporation happens at piping surface.
45
CS-E9DKRW CU-E9DKR / CS-E12DKRW CU-E12DKR
HOW TO OPERATE
Operation Details
Auto,Heat,Cool,Dr
D y
AUTO - Automatic Operation
• The unit will automatically select
the operation mode according
to the setting, outdoor and room
temperature. During operation mode
selection, power indicator blinks.
For every 30 minutes, the operation
mode is reselected.
1
HEAT - Heating Operation
Start the
operation.
• Enables you to enjoy the warming
effect at your preferred setting
temperature.
• For cold air prevention, air might
not blow out immediately and
power indicator blinks when
operation starts.
2
• Also operates in defrost mode
(maximum 10 minutes) where by
the power indicator blinks. The
melted frost is drained at outdoor
unit and indoor fan is stopped.
Select the
desired
operation.
COOL - Cooling Operation
• Enables you to enjoy the cooling
effect at your preferred setting
temperature.
AUTO
DRY
HEAT
COOL
DRY - Soft Dry Operation
3
• Enables you to set the desired
temperature at low fan speed which
provides you with the dehumidifying
surroundings.
Set the
temperature.
(16°C~30°C)
Supersonic air purifying device (super alleru-buster) operates
automatically while the air conditioner is switched on.
Powerful, Quiet and Ion operations could be activated in all
operation modes.
Press
button again to stop the operation.
Hint
To save electricity, close the curtains when using air conditioner to prevent sunlight and heat from coming in.
Troubleshooting
The room has a peculiar odour.
This may be a damp smell emitted by the wall, carpet, furniture or
clothing in the room.
Air conditioner does not cool or heat efficiently.
Ensure the temperature has been set correctly.
Ensure windows and doors have been closed properly.
Ensure filters are cleaned or replaced when necessary.
Ensure inlet and outlet vents of the units have not been obstructed.
46
CS-E9DKRW CU-E9DKR / CS-E12DKRW CU-E12DKR
HOW TO OPERATE
Operations Details
Pow erful, Quiet, Ion, Fan Speed,
Air Sw ing
POWERFUL
• To achieve setting temperature
quickly.
QUIET
• To provide a quiet environment.
ION
ION
Enables ion
operation.
QUIET
• To provide fresh air effect by
producing negative ions.
Enables quiet
operation.
• Ion operation could be activated
independently.
• Press
button to stop the
operation.
FAN SPEED
POWERFUL
• To provide you with the various fan
speed selections.
Enables
powerful
operation.
• There are 5 levels of fan speed in
addition to automatic fan speed.
• Automatic fan speed:
The speed of the indoor fan is
automatically adjusted according to
the operation.
AIR SWING
FAN SPEED
D
Select fan speed.
• To ventilate air in the room.
• There are 5 selections in addition to
automatic vertical air flow direction.
• If automatic vertical airflow direction
has been set, the louver swings up
and down automatically.
AIR SWING
Adjust the vertical
or horizontal airflow
direction louver.
• To ventilate air in the room.
• There are 5 selections in addition
to automatic horizontal air flow
direction.
• If automatic horizontal airflow
direction has been set, the louver
swings left and right automatically.
Powerful and Quiet operations could not be activated at the
same time.
• Please do not adjust the vertical and
horizontal airflow direction louver
manually.
Powerful, Quiet and Ion operations could be cancelled by
pressing the respective button again.
Hints
If you wish to have the cool air blowing directly on you, set the airflow direction downward but not for an excessive length of time,
as it may harm your health.
Approximately 10% of electricity can be saved if you set the temperature 1°C higher in cooling operation or 2°C lower in heating
operation than the desired temperature.
Troubleshooting
ION indicator on the indoor unit is blinking.
Press ION button twice. If the indicator is still blinking, please consult
the dealer.
Indoor fan stops occasionally during Automatic Fan
Speed setting.
This is an advanced feature that helps to remove smell from the
surrounding area during operation.
Indoor fan stops occasionally during heating operation. To avoids unintended cooling effect.
47
CS-E9DKRW CU-E9DKR / CS-E12DKRW CU-E12DKR
Operation Details
HOW TO OPERATE
Timer
TIMER
• Use the ON timer to turn on the air
conditioner at the desired time. This
will give you a cooling or warming
environment, e.g. when you return
from work or wake up.
• When the ON timer is set, operation
will start up to 35 minutes before the
actual set time.
• Use the OFF timer to stop the air
conditioner operation at the desired
time. This can save electricity while
you are going out or sleeping.
• The set timer will repeat daily once
it is set.
• If there is a power failure, you can
press SET button to restore the
previous setting once the power is
resumed.
1
Select ON or
OFF timer.
2
Set the
desired time.
• If the timer is cancelled, you can
restore the previous setting by
pressing SET button.
CHECK
• When there is error, the unit stops
its operation and timer indicator
blinks.
3
1. Press for 5 seconds.
Confirm the
setting.
CANCEL
2. Browse for respective error code,
where “beep” sounds are heard.
Cancel the
selected timer.
3. Turn off the power supply and call
authorized distributor.
Note:
Press the ‘Reset’ button to quit
checking.
Unit might operate with limited function
depending on error found.
(Operation starts, 4 “beep” sound is
heard)
Ensure the clock on the remote control has been set
correctly.
You could use the ON and OFF timers at the same time.
To cancel either the ON or OFF timer, press
press
.
or
, then
Hint
Press CLOCK more than 10 seconds to change the time format from 24 hours to AM/PM format.
For your convenience, you could set the air conditioner to operate automatically by using both ON and OFF timer.
Troubleshooting
TIMER indicator always on.
Timer is activated and the setting will repeat itself daily.
POWER indicator is blinking 35 minutes before ON
timer is activated.
The unit is determining the operation mode by sensing the room
temperature. This happens when it has been set to AUTO operation
mode.
48
CS-E9DKRW CU-E9DKR / CS-E12DKRW CU-E12DKR
CARE & CLEANING
Washing Instructions
Switch off the power supply
before cleaning
FRONT PANEL
Raise and pull to remove.
Wash and dry.
• Do not use benzene, thinner or
scouring powder.
• Use soaps or neutral household
detergent ( pH7) only.
≃
• Do not use water with temperature
higher than 40°C.
INDOOR UNIT
• Wipe the unit gently with a soft, dry
cloth.
AIR FILTER
AIR FILTER
• It is recommended to clean the air
filters once every 2 weeks.
Vacuum, wash and dry.
• Purchase the replacement filter if it
is damaged.
Part no.: CWD001144
SUPER ALLERU-BUSTER
• It is recommended to clean the filter
every 6 months.
• Replace the filter every 3 years or
purchase the replacement filter if it
is damaged.
Remove
Part no.: CZ-SA13P
POWER TIMER QUIET POWERFUL ION
IONIZER
Remove
• It is recommended to clean the
ionizer every 6 months.
Preparation for extended
Non-operation
SUPERSONIC AIR
PURIFYING DEVICE
D
INDOOR
D
UNIT
Wipe gently.
Vacuum the super
alleru-buster filter.
Remove
• Operate the unit for 2~3 hours using
ion operation to dry the internal parts.
• Turn off the power supply.
• Remove the remote control batteries.
Pre-season Inspection
IONIZER
Clean with cotton
bud.
• This inspection is recommended
before operating the air conditioner
at every season.
• Check if the remote control batteries
needed to be replaced.
• Ensure there is no obstruction at all
air intake and outlet vents.
• After the start of operation for 15
minutes, it is normal if the
temperature differences between
air intake and outlet vents at indoor
unit is:Operation
Vacuum, wash and
dry the frame.
Temperature
Cooling
8°C
Heating
14°C
Hints
Clean the filter regularly as dirty filters will cause unpurified air, low cooling or heating capacity, unpleasant smells and higher
energy consumption.
The unit will become dirty and the performance of the unit will decrease after used for several seasons. Please consult an
authorized dealer to perform seasonal inspections in addition to regular cleaning.
This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner
from being damaged by abnormally strong lightning activity, you may switch off the power supply.
49