advertisement
▼
Scroll to page 2
of
8
![Triton Systems RT2000 Series User manual | Manualzz Triton Systems RT2000 Series User manual | Manualzz](http://s3.manualzz.com/store/data/051843229_1-a8909c8a9035c6af3b9a94131da91373-360x466.png)
Model RT2000 (X2) Quick Reference Guide THIS AREA FOR SERVICE PROVIDER CONTACT INFORMATION: TDN 07100-00098 Oct 31 2008 MANAGEMENT FUNCTIONS - Access Instructions 1. At ATM Welcome Screen, press and hold down the <CTRL> key (Lower-right corner of keypad), press <1> key, then release both keys. The Password Access prompt is displayed. 2. Enter password and select <Enter>. The Management Functions MAIN MENU is displayed. RESTART / SHUTDOWN TERMINAL Follow Access Instructions to enter Management Functions. Select SYSTEM PARAMETERS. RESTART TERMINAL: This function reboots the terminal. SHUTDOWN TERMINAL: This function powers-down the terminals operating system. When prompted that shutdown is complete, turn On/Off switch on power supply to <Off> position. TERMINAL CONFIGURATION REPORT Follow Access instructions to enter Management Functions. Select DIAGNOSTICS > TERMINAL STATUS. CONFIGURATION SUMMARY: This summary is a comprehensive report of current terminal configuration and hardware status information. NOTE: It is highly recommended that this report be printed and saved after initial setup and whenever changes are made to the terminals configuration. 2 DIAGNOSTICS Follow Access instructions to enter Management Functions. Select DIAGNOSTICS > DISPENSER. PURGE: This instructs the dispenser to remove any notes (jams) in feed path. TEST DISPENSE: This instructs the dispenser to dispense minimum one note from each installed cassette into the reject cassette/area. Select DIAGNOSTICS > PRINTER. RESET / TEST PRINTER: This instructs the printer to re initialize and perform a test printout. CLOSE FUNCTIONS Follow Access instructions to enter Management Functions. Select TERMINAL CLOSE FUNCTIONS. DAY CLOSE: This option is used to complete daily balancing of the ATM with the processor. Totals are cleared and switched to the next business day. TRIAL CLOSE: This option functions like a Day Close except the totals are not cleared. JOURNAL FUNCTIONS Follow Access instructions to enter Management Functions. Select JOURNAL. PRINT LAST X: To view/print previously records, use the Print Last X option. audited or unaudited Example: Entering the number ‘50’ will let you curred. You may print to the receipt printer. view the last 3 50 transactions/events that have oc- CASSETTE CLOSE FUNCTIONS (From the Front Display) Follow Access instructions Select CASSETTE CLOSE. Select cassette(s) to to enter Management Functions. Select TERMINAL CLOSE Functions. Close. A check identifies which cassette(s) are selected. ter>. mark ( √ ) Press <En- After cassette(s) have been reinserted in the dis- penser, press <Enter>. Place selected cassette(s) IN SERVICE. Press <Enter>. Note: For TDM-200/250 dispensers. This A Close report is displayed to be printed or saved. operation will reset the number of bills in the cassette(s) to ZERO (0). Press <Enter>. Enter Cassette Quantity (number of notes, NOT Press <Enter> to accept entry. Repeat for each selected cassette. value) for the selected cassette(s). A Trial Cassette Close report automatically is for starting point reference. Press <Enter> to return displayed to be printed or saved. Print and retain a copy Remove and Replenish the selected cassette(s). Follow Cassette Replenishment Procedures. to Close functions. **IMPORTANT** Ensure the MULTIPLE AMOUNT parameter matches the denomination of currency in each Note Cassette! 4 CASSETTE CLOSE FUNCTIONS (From the Rear Operator Service Panel (Touchscreen) Press to Start. Close Cassette(s) - Touch cas- sette options on touchpad until “Asterick” appears. Select “Continue”. Select the cassettes to close. WARNING: Cassette totals will be reset for the selected cassettes * Cassette A: $10.00 Continue Select the cassettes to place in service. * Cassette A: $10.00 * Cassette B: $20.00 * Cassette B: $20.00 Enter Password. Place cassettes “In-Service”. Touch cassette options on touchpad until “A sterick ” appears . Select “Continue”. Continue Exit Cassette Close report appears. Print report. Press “Exit” when completed. *** Cassette Close *** Enter Cassette Qty (each). Press “OK”. Cassette Quantity - Cassette A: Please enter the number of bills that are in the cassette (not the value). 200 Cassette A S elect “T erminal C lose Functions”. Last Close Date/Time: 6/4/2007 7:49:39 AM Start Quantity: Qty: 200 Amount: $2000.00 Dispensed: Qty: 50 Amount: $500.00 Remaining: Qty: 150 Amount: $1500.00 Select “Cassette Close”. Remove /replenish cassette(s). Press “Enter”. You may now remove and replenish the cassettes. Press ENTER when done. Enter 5 Exit 1 2 3 CANCEL 4 5 6 CHANGE 7 8 9 OK < 0 > Trial Cassette Close report appears. Print report. Press “Exit” when completed. *** Trial Cassette Close *** Cassette A Last Close Date/Time: 6/4/2007 7:55:39 AM Start Quantity: Qty: 200 Amount: $2000.00 Dispensed: Qty: 0 Amount: $00.00 Remaining: Qty: 200 Amount: $2000.00 REPLENISH CASSETTE(S) Note: The RT2000 utilizes TDM dispensers. Currency replenishment for a cassette is the same whether its a single or dual-cassette dispenser mechanism. STEP 1 ACTION Unlock / open vault cabinet door. The dispenser is mounted to a sliding tray. tray ACTION STEP 4 Note: The DOES NOT Place cassette(s) on a flat surface. U nlock note cas - sette with supplied need to be extended key. for currency re - Move plenishment. Open lid. pusher plate to war d s r e ar o f cassette and secure 2 Remove in place with key reject cassette by grasping the latch mechanism. box and pulling from the dispenser. Unlock and remove any rejected notes. 5 Count the number of bills that remain in the cassette, if any. Count the number of bills that are being added to the remaining notes. The TOTAL of these amounts will be entered in the “Enter Cassette Quantity” prompt for Cassette Close procedure. Close, lock, and reinsert the reject cassette back into the dispenser. 6 DO NOT recycle rejected notes! 3 R emove release the latch allowing the packer plate to move forward against the notes. the note cassette(s) Place currency in the cassette and slowly Close by lid, lock cassette and rein - grasping the green sert back into the handle and pull dispenser . from the dispenser. E nsure cassette is fully inserted. 6 REPLENISH RECEIPT PAPER Note: This procedure requires terminal is powered up. STEP 1 ACTION Open the rear cabinet sleeve door. If paper remains on roll, cut or tear pa p e r STEP ACTION 4 R elease (O pen ) the blue tension lever shown. Remove any paper from the printer/ cutter assembly. Move between the ten- sion lever back roll and printer. to the CLOSED position . Ro- tate the Down printer assem bly. 2 Remove 5 spent pa- per roll and spind l e f r o m pa p e r bracket. 3 Pull Install new paper roll/ spindle in bracket. Paper feeds from BOTTOM of roll! release pin, 6 grasp handle, and Feed end of paper over bar and into p r i n t e r ta k e - u p rotate printer as- slot. sembly up to the service position. Printer will a u t o ma t i c a l l y grip and pull paper Note: This position into feed path. also allows receipt access for printing reports if using the Rear Service Panel 7 Closed Open COMBINATION LOCKS Introduction The security cabinet can be secured using either a mechanical or electronic combination lock. This page covers how to operate the combination of either lock. Operating the Mechanical Lock Unlocking the Lock There are two marks on the dial ring. The index at the top is used for opening the lock, The index 30 degrees to the left is used only when changing the combination. The dial should always be turned slowly and evenly. A revolution is counted each time the selected number is Do not turn the dial back to compensate for over-dialing a number. If, when dialing the combination, any number is turned beyond the index, the entire sequence must be repeated. aligned with the opening index. Unlocking 3-number combinations (For Example, “50-25-50”) 1.Turn the dial to the Left at least four (4) complete turns to clear the combination lock to accept the combination. 2.Using the ‘Opening Index’, turn the dial to the Left, stopping when ‘50’ is aligned with the opening index, the Fourth time. 3.Turn the dial to the Right, stopping when ‘25’ is aligned with the opening index, the Third time. 4.Turn the dial to the Left, stopping when ‘50’ is aligned with the opening index, the Second time. 5.Turn the dial slowly to the Right until the bolt retracts. Operating the Electronic Lock The electronic lock combination consists of six digits. Upon arrival, the combination of the lock should already be preset to 1-2-3-4-5-6. Entering the Combination 1.Enter the preset combination and check for proper operation. After each keypress, the lock will beep. After the final digit has been entered, the lock will beep twice, and the open period will begin. 2. When a valid combination has been entered, the operator will have approximately 4 seconds to open the lock. 3.To open the lock, turn the dial clockwise. 4. After the lock is opened, the cabinet door may be opened. Lockout Feature The lock includes a ‘Wrong Try Penalty’ lockout feature that prevents entry from unauthorized personnel. This feature performs as follows: • Entry of four (4) consecutive invalid combinations starts a 5-minute delay period. -LED flashes red at ten (10) second intervals. • At the 5-minute end of the delay period, two delay. (2) more consecutive invalid combinations will restart an additional 8
advertisement