Triton Systems RT2000 Series User manual

Add to My manuals
8 Pages

advertisement

Triton Systems RT2000 Series User manual | Manualzz
Model RT2000 (X2)
Quick Reference Guide
THIS AREA FOR SERVICE PROVIDER
CONTACT INFORMATION:
TDN 07100-00098
Oct 31 2008
MANAGEMENT FUNCTIONS
- Access Instructions 1.
At ATM Welcome Screen, press and hold down the <CTRL>
key (Lower-right corner of keypad), press <1> key, then release
both keys. The Password Access prompt is displayed.
2. Enter password and select <Enter>. The Management Functions MAIN MENU is displayed.
RESTART / SHUTDOWN TERMINAL
Follow Access Instructions to enter Management Functions. Select
SYSTEM PARAMETERS.
RESTART TERMINAL: This function reboots the terminal.
SHUTDOWN TERMINAL: This function powers-down the terminals
operating system.
When prompted that shutdown is complete, turn
On/Off switch on power supply to <Off> position.
TERMINAL CONFIGURATION REPORT
Follow Access instructions to enter Management Functions. Select
DIAGNOSTICS > TERMINAL STATUS.
CONFIGURATION SUMMARY: This summary is a comprehensive
report of current terminal configuration and hardware status
information.
NOTE: It is highly recommended that this report be printed and saved after initial setup and whenever
changes are made to the terminals configuration.
2
DIAGNOSTICS
Follow Access instructions to enter Management Functions. Select
DIAGNOSTICS > DISPENSER.
PURGE: This instructs the dispenser to remove any notes (jams) in
feed path.
TEST DISPENSE: This
instructs the dispenser to dispense minimum
one note from each installed cassette into the reject cassette/area.
Select DIAGNOSTICS > PRINTER.
RESET / TEST PRINTER:
This
instructs the printer to re initialize and perform a test
printout.
CLOSE FUNCTIONS
Follow Access instructions to enter Management Functions. Select
TERMINAL CLOSE FUNCTIONS.
DAY CLOSE: This option is used to complete daily balancing of
the ATM with the processor. Totals are cleared and switched to
the next business day.
TRIAL CLOSE: This option functions like a Day Close except the totals are not cleared.
JOURNAL FUNCTIONS
Follow Access instructions to enter Management Functions. Select
JOURNAL.
PRINT LAST X: To view/print previously
records, use the Print Last X option.
audited or unaudited
Example: Entering the number ‘50’ will let you
curred. You may print to the receipt printer.
view the last
3
50
transactions/events that have oc-
CASSETTE CLOSE FUNCTIONS
(From the Front Display)
Follow Access instructions
Select CASSETTE CLOSE.

Select
cassette(s) to
to enter
Management Functions. Select TERMINAL CLOSE Functions.
Close. A check
identifies which cassette(s) are selected.
ter>.

mark ( √ )
Press <En-
After
cassette(s) have been reinserted in the dis-
penser, press
<Enter>.

Place selected cassette(s) IN SERVICE. Press
<Enter>. Note: For TDM-200/250 dispensers.

This
A Close report is displayed to be printed or saved.
operation will reset the number of bills in the
cassette(s) to
ZERO (0). Press <Enter>.

Enter Cassette Quantity (number of notes, NOT
Press <Enter> to
accept entry. Repeat for each selected cassette.
value) for the selected cassette(s).


A Trial Cassette Close
report automatically is
for starting point reference.
Press <Enter> to return
displayed to be printed or saved. Print and retain a copy
Remove and Replenish the selected cassette(s).
Follow Cassette Replenishment Procedures.
to
Close functions.
**IMPORTANT**
Ensure the MULTIPLE AMOUNT parameter matches
the denomination of currency in each Note Cassette!
4
CASSETTE CLOSE FUNCTIONS
(From the Rear Operator Service Panel (Touchscreen)

Press to Start.

Close Cassette(s) - Touch cas-
sette options on touchpad until
“Asterick” appears. Select “Continue”.
Select the cassettes to close.
WARNING: Cassette totals will be
reset for the selected cassettes
* Cassette A: $10.00

Continue
Select the cassettes to place in
service.
* Cassette A: $10.00
* Cassette B: $20.00
* Cassette B: $20.00
Enter Password.
Place cassettes “In-Service”.
Touch cassette options on touchpad until “A sterick ” appears .
Select “Continue”.

Continue
Exit
 Cassette Close report appears.
Print report. Press “Exit” when
completed.
*** Cassette Close ***

Enter Cassette Qty (each).
Press “OK”.
Cassette Quantity - Cassette A:
Please enter the number of bills that
are in the cassette (not the value).
200
Cassette A

S elect “T erminal C lose
Functions”.
Last Close Date/Time:
6/4/2007 7:49:39 AM
Start Quantity:
Qty:
200
Amount: $2000.00
Dispensed:
Qty:
50
Amount: $500.00
Remaining:
Qty:
150
Amount: $1500.00


Select “Cassette Close”.
Remove /replenish cassette(s).
Press “Enter”.
You may now remove and replenish
the cassettes. Press ENTER when
done.
Enter
5
Exit
1
2 3
CANCEL
4 5 6
CHANGE
7 8
9
OK
< 0 >
 Trial Cassette Close report appears.
Print report. Press “Exit”
when completed.
*** Trial Cassette Close ***
Cassette A
Last Close Date/Time:
6/4/2007 7:55:39 AM
Start Quantity:
Qty:
200
Amount: $2000.00
Dispensed:
Qty:
0
Amount: $00.00
Remaining:
Qty:
200
Amount: $2000.00
REPLENISH CASSETTE(S)
Note: The RT2000 utilizes TDM dispensers. Currency replenishment for a cassette is the same
whether its a single or dual-cassette dispenser
mechanism.
STEP
1
ACTION
Unlock / open vault
cabinet door. The
dispenser is mounted to a sliding
tray.
tray
ACTION
STEP
4
Note: The
DOES NOT
Place cassette(s) on a flat surface.
U nlock
note cas -
sette with supplied
need to be extended
key.
for currency re -
Move
plenishment.
Open
lid.
pusher plate
to war d s r e ar o f
cassette and secure
2
Remove
in place with key
reject cassette by grasping the
latch mechanism.
box and pulling from the dispenser.
Unlock and remove any rejected notes.
5
Count the number of bills that remain in
the cassette, if any.
Count the number of bills that are being
added to the remaining notes.
The TOTAL of these amounts will be entered in the “Enter Cassette Quantity”
prompt for Cassette Close procedure.
Close, lock, and reinsert the reject cassette back into the dispenser.
6
DO NOT recycle rejected notes!
3
R emove
release the latch allowing the packer
plate to move forward against the notes.
the note
cassette(s)
Place currency in the cassette and slowly
Close
by
lid, lock
cassette and rein -
grasping the green
sert back into the
handle and pull
dispenser .
from the dispenser.
E nsure
cassette is fully inserted.
6
REPLENISH RECEIPT PAPER
Note: This procedure requires terminal is powered up.
STEP
1
ACTION
Open the rear cabinet sleeve door.
If paper remains on
roll, cut or tear
pa p e r
STEP
ACTION
4
R elease (O pen ) the blue tension lever
shown. Remove any paper from the printer/
cutter assembly.
Move
between
the ten-
sion lever back
roll and printer.
to the CLOSED
position .
Ro-
tate
the
Down
printer assem bly.
2
Remove
5
spent pa-
per roll and spind l e f r o m pa p e r
bracket.
3
Pull
Install new paper
roll/ spindle in
bracket.
Paper feeds from
BOTTOM of roll!
release pin,
6
grasp handle, and
Feed
end of paper
over bar and into
p r i n t e r ta k e - u p
rotate printer as-
slot.
sembly up to the
service position.
Printer will
a u t o ma t i c a l l y
grip and pull paper
Note: This position
into feed path.
also allows receipt
access for printing
reports if using the
Rear Service Panel
7
Closed
Open
COMBINATION LOCKS
Introduction
The security cabinet can be secured using either a mechanical or electronic combination lock. This page covers
how to operate the combination of either lock.
Operating the Mechanical Lock
Unlocking the Lock
There are two marks on the dial ring. The index at the top is used for opening the lock, The index 30 degrees to
the left is used only when changing the combination.
The
dial should always be turned slowly and evenly.
A revolution is counted each time the selected number is
Do not turn the dial back to compensate for over-dialing a number. If, when dialing
the combination, any number is turned beyond the index, the entire sequence must be repeated.
aligned with the opening index.
Unlocking 3-number combinations (For Example, “50-25-50”)
1.Turn the dial to the Left at least four (4) complete turns to clear the combination lock to accept the
combination.
2.Using the ‘Opening Index’, turn the dial to the Left, stopping when ‘50’ is aligned with the opening index,
the Fourth time.
3.Turn the dial to the Right, stopping when ‘25’ is aligned with the opening index, the Third time.
4.Turn the dial to the Left, stopping when ‘50’ is aligned with the opening index, the Second time.
5.Turn the dial slowly to the Right until the bolt retracts.
Operating the Electronic Lock
The electronic lock combination consists of six digits. Upon arrival, the combination of the lock should already
be preset to
1-2-3-4-5-6.
Entering the Combination
1.Enter the preset combination and check for proper operation. After each keypress, the lock will beep. After
the final digit has been entered, the lock will beep twice, and the open period will begin.
2.
When a valid combination has been entered, the operator will have approximately 4 seconds to open the lock.
3.To open the lock, turn the dial clockwise.
4.
After the lock is opened, the cabinet door may be opened.
Lockout Feature
The lock includes a ‘Wrong Try Penalty’ lockout feature that prevents entry from unauthorized personnel. This
feature performs as follows:
•
Entry of four (4) consecutive invalid combinations starts a 5-minute delay period.
-LED flashes red at ten (10) second intervals.
•
At the
5-minute end of the delay period, two
delay.
(2)
more consecutive invalid combinations will restart an additional
8