UNVENTED (VENT-FREE) INFRARED GAS HEATER
SAFETY INFORMATION AND INSTALLATION MANUAL
Model VN30A Shown
Models vn18a, VN18Ta, vp16a, VP16Ta,
vp26a, VP26Ta, vn30a and VN30Ta
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other ­ flammable
vapors and liquids in the ­vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.desatech.com
Table of Contents
Safety Information................................................ 2
Local Codes......................................................... 4
Product Identification............................................ 4
Unpacking............................................................ 4
Product Features.................................................. 4
Air For Combustion and Ventilation...................... 5
Installation............................................................ 7
Operating Heater................................................ 14
Inspecting Heater............................................... 16
Cleaning and Maintenance................................. 17
Safety Information
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to
this manual for correct installation and operational
procedures. For assistance or additional information consult a qualified
installer, service agency or
the gas supplier.
WARNING: This is an
unvented gas-fired heater.
It uses air (oxygen) from the
room in which it is installed.
Provisions for adequate
combustion and ventilation air must be provided.
Refer to Air for Combustion
and Ventilation section on
page 5 of this manual.
This appliance is only for
use with the type of gas
indicated on the rating
plate. This appliance is
not convertible for use
with other gases.
Troubleshooting.................................................. 18
Specifications..................................................... 21
Illustrated Parts Breakdown and Parts List........ 22
Replacement Parts............................................. 26
Service Hints...................................................... 26
Technical Service............................................... 26
Accessories........................................................ 26
Service Publications........................................... 26
Parts Central...................................................... 27
Warranty Information............................Back Cover
This appliance may be installed in an aftermarket,*
permanently located,
manufactured (mobile)
home, where not prohibited by local codes.
* Aftermarket: Completion of sale, not for
purpose of resale, from the manufacturer
WARNING: This product contains and/or generates chemicals
known to the State of California
to cause cancer or birth defects
or other reproductive harm.
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble,
operate or service this heater.
Improper use of this heater can
cause serious injury or death
from burns, fire, explosion,
electrical shock and carbon
monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon
monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs,
the heater may not be working properly. Get fresh
air at once! Have heater serviced. Some people
are more affected by carbon monoxide than others.
These include pregnant women, people with heart
or lung disease or anemia, those under the influence of alcohol and those at high altitudes.
www.desatech.com
113052-01F
Safety Information
Continued
Natural and Propane/LP Gas: Natural and Propane/
LP gases are odorless. An odor-making agent is
added to these gases. The odor helps you detect
a gas leak. However, the odor added to the gas
can fade. Gas may be present even though no
odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your
guide to safe and proper operation of this heater.
WARNING: Any change to
this heater or its controls can
be dangerous.
WARNING: Do not use a blower insert, heat exchanger insert
or other accessory not approved
for use with this heater.
Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.
Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the heater.
Surface of heater becomes very
hot when running heater. Keep
children and adults away from
hot surface to avoid burns or
clothing ignition. Heater will
remain hot for a time after shutdown. Allow surface to cool
before touching.
Carefully supervise young children when they are in the same
room with heater.
Make sure grill guard is in place
before running heater.
113052-01F
Keep the appliance area clear
and free from combustible materials, gasoline and other flammable vapors and liquids.
1. This appliance is only for use with the type
of gas indicated on the rating plate. This appliance is not convertible for use with other
gases.
2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply
tank(s) outdoors.
3. This heater shall not be installed in a bedroom
or bathroom.
4. If you smell gas
• Shut off gas supply
• Do not try to light any appliance
• Do not touch any electrical switch; do not
use any phone in your building
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions
• If you cannot reach your gas supplier, call
the fire department
5. Always run heater with plaque control knob
at the 1, 2, 3 or 4 locked positions. Never
set control knob between locked positions.
Poor combustion and higher levels of carbon
monoxide may result.
6. This heater needs fresh, outside air ventilation
to run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater if
not enough fresh air is available. See Air for
Combustion and Ventilation, page 5.
7. Keep all air openings in front and bottom of
heater clear and free of debris. This will insure
enough air for proper combustion.
8. If heater shuts off, do not relight until you
provide fresh, outside air. If heater keeps
shutting off, have it serviced.
9. Do not run heater
• where flammable liquids or vapors are used
or stored
• under dusty conditions
10. Do not use heater if any part has been under
water. Immediately call a qualified service
technician to inspect the room heater and to
replace any part of the control system and any
gas control which has been under water.
11. Turn off and unplug heater and let cool before
servicing. Only a qualified service person
should service and repair heater.
www.desatech.com
SAFETY INFORMATION
Continued
12. Operating heater above elevations of 4,500
feet could cause pilot outage.
13. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.
14. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
15. Provide adequate clearances around air
openings.
Product
Identification
Ignitor Button
Grill
Guard
Plaque
Local Codes
Install and use heater with care. Follow all local
codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
State of Massachusetts: The installation must
be made by a licensed plumber or gas fitter in
the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired
supplemental room heaters shall provide to
each purchaser a copy of 527 CMR 30 upon
sale of the unit.
Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.
Control
Knob
Front Panel
Heater Cabinet
Figure 1 - Vent-Free Gas Heater
Unpacking
1. Remove heater from carton.
2. Remove all protective packaging applied to
heater for shipment.
3. Check heater for any shipping damage. If
heater is damaged, promptly return to where
you bought heater.
Product Features
Safety Device
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free room
heaters. The ODS/pilot shuts off the heater if there
is not enough fresh air.
Ignition System
This heater has an electronic ignitor to light heater
fuel supply.
Thermostatic Heat Control
(Thermostat Models Only)
Thermostat models have a thermostat sensing
bulb and a control valve. This results in the greatest heater comfort. This can also result in lower
gas bills.
www.desatech.com
113052-01F
Air For Combustion
and Ventilation
WARNING: This heater shall
not be installed in a confined space
or unusually tight construction
unless provisions are provided
for adequate combustion and
ventilation air. Read the following
instructions to insure proper fresh
air for this and other fuel-burning
appliances in your home.
Today’s homes are built more energy efficient
than ever. New materials, increased insulation and
new construction methods help reduce heat loss
in homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out
and the warm air in. During heating months, home
owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must
enter your home. All fuel-burning appliances need
fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers and fuel
burning appliances draw air from the house to
operate. You must provide adequate fresh air for
these appliances. This will insure proper venting
of vented fuel-burning appliances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section 5.3,
Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 5 through 7 will help
you classify your space and provide adequate
ventilation.
113052-01F
Unusually Tight Construction
The air that leaks around doors and windows
may provide enough fresh air for combustion and
ventilation. However, in buildings of unusually
tight construction, you must provide additional
fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the outside
atmosphere have a continuous water vapor
retarder with a rating of one perm (6 x 10-11 kg
per pa-sec-m2) or less with openings gasketed
or sealed and
b. weather stripping has been added on openable
windows and doors and
c. caulking or sealants are applied to areas such
as joints around window and door frames,
between sole plates and floors, between
wall-ceiling joints, between wall panels, at
penetrations for plumbing, electrical and gas
lines and at other openings.
If your home meets all of these three criteria, you
must provide additional fresh air. See Ventilation
Air From Outdoors, page 7.
If your home does not meet all of the three criteria
above, proceed to Determining Fresh-Air Flow
For Heater Location, page 6.
Confined and Unconfined Space
The National Fuel Gas Code, ANSI Z223.1/NFPA
54 defines a confined space as a space whose
volume is less than 50 cubic feet per 1,000 Btu
per hour (4.8 m3 per kw) of the aggregate input
rating of all appliances installed in that space and
an unconfined space as a space whose volume is
not less than 50 cubic feet per 1,000 Btu per hour
(4.8 m3 per kw) of the aggregate input rating of
all appliances installed in that space. Rooms communicating directly with the space in which the
appliances are installed*, through openings not
furnished with doors, are considered a part of the
unconfined space.
* Adjoining rooms are communicating only if
there are doorless passageways or ventilation grills
between them.
www.desatech.com
AIR FOR COMBUSTION
AND VENTILATION
Continued
DETERMINING FRESH-AIR FLOW
FOR Heater LOCATION
Determining if You Have a Confined or
Unconfined Space
Use this work sheet to determine if you have a
confined or unconfined space.
Space: Includes the room in which you will install
heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x
width x height).
Length x Width x Height =__________cu. ft.
(volume of space)
Example: Space size 20 ft. (length) x 16 ft.
(width) x 8 ft. (ceiling height) = 2560 cu. ft.
(volume of space)
If additional ventilation to adjoining room is
supplied with grills or openings, add the volume
of these rooms to the total volume of the space.
2. Multiply the space volume by 20 to determine
the maximum Btu/Hr the space can support.
___________ (volume of space) x 20 = (Maximum Btu/Hr the space can support)
Example: 2560 cu. ft. (volume of space) x 20 =
51,200 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in
the space.
Vent-free heater
____________ Btu/Hr
Gas water heater*
____________ Btu/Hr
Gas furnace
____________ Btu/Hr
Vented gas heater
____________ Btu/Hr
Gas fireplace logs
____________ Btu/Hr
Other gas appliances* +___________ Btu/Hr
Total
=___________ Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors
and vents to the outdoors.
Example:
40,000
Gas water heater
____________
Btu/Hr
20,000
Vent-free heater
+___________
Btu/Hr
60,000
Total
=___________
Btu/Hr
4. Compare the maximum Btu/Hr the space can
support with the actual amount of Btu/Hr used.
__________Btu/Hr (maximum the space can support)
__________Btu/Hr (actual amount of Btu/Hr used)
Example: 51,200 Btu/Hr (maximum the space
can support)
60,000 Btu/Hr (actual amount of
Btu/Hr used)
The space in the above example is a confined space
because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide
additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined
space, remove door to adjoining room or add
ventilation grills between rooms. See Ventilation
Air From Inside Building.
B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7.
C. Install a lower Btu/Hr heater, if lower Btu/Hr size
makes room unconfined.
If the actual Btu/Hr used is less than the maximum
Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh
air ventilation.
WARNING: If the area in
which the heater may be operated is smaller than that defined
as an unconfined space or if the
building is of unusually tight
construction, provide adequate
combustion and ventilation air
by one of the methods described
in the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 Section 5.3
or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining
unconfined space, you must provide two permanent openings: one within 12" of the ceiling and
one within 12" of the floor on the wall connecting
the two spaces (see options 1 and 2, Figure 2,
page 7). You can also remove door into adjoining
room (see option 3, Figure 2, page 7). Follow the
National Fuel Gas Code, ANSI Z223.1/NFPA 54,
Section 5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
www.desatech.com
113052-01F
AIR FOR COMBUSTION
AND VENTILATION
Continued
12"
Ventilation
Grills into
Adjoining
Room,
Option 1
Ventilation Grills
Into Adjoining Room,
Option 2
Or
Remove
Door into
Adjoining
Room,
Option 3
12"
Installation
NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your primary
heating system. Do not install this
heater as your primary heat source.
If you have a central heating system,
you may run system’s circulating
blower while using heater. This will
help circulate the heat throughout
the house. In the event of a power
outage, you can use this heater as
your primary heat source.
WARNING: A qualified service person must install heater.
Follow all local codes.
Figure 2 - Ventilation Air from Inside
Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or
ducts. You must provide two permanent openings:
one within 12" of the ceiling and one within 12"
of the floor. Connect these items directly to the
outdoors or spaces open to the outdoors. These
spaces include attics and crawl spaces. Follow the
National Fuel Gas Code, ANSI Z223.1/NFPA 54,
Section 5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet
or outlet air into attic if attic has a thermostatcontrolled power vent. Heated air entering the attic
will activate the power vent.
CHECK GAS TYPE
Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas
type, do not install heater. Call dealer where you
bought heater for proper type heater.
This appliance is only for use with
the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
WARNING: This appliance
is equipped for (natural or propane/LP) gas. Field conversion
is not permitted.
INSTALLATION ITEMS
Outlet
Air
Outlet
Air
Ventilated
Attic
To Attic
To
Crawl
Space
Inlet
Air
Inlet Air
Ventilated
Crawl Space
Figure 3 - Ventilation Air from Outdoors
113052-01F
Before installing heater, make sure you have the
items listed below.
• for propane/LP gas, external regulator (supplied
by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• ground joint union
• sediment trap
• tee joint
• pipe wrench
• for natural gas, test gauge connection*
* A CSA design-certified equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. The optional CSA designcertified equipment shutoff valve can be purchased
from your dealer. See Accessories, page 26.
www.desatech.com
Installation
Continued
LOCATING HEATER
WARNING: Maintain the
minimum clearances shown
in Figure 4. If you can, provide
greater clearances from floor,
ceiling and joining wall.
You can locate heater on the floor, away from a
wall. A wall mounting bracket and floor base stand
are included with this heater. Determine which
method is best for your application.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing or other flammable objects
are less than 36" from the front,
top or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must
be at least 18" above floor
• locate heater where moving
vehicle will not hit it
CEILING
36"
Minimum
10"
Minimum
From
Sides Of
Heater
CAUTION: This heater creates warm air currents. These
currents move heat to wall surfaces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
IMPORTANT: Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation air may
cause mildew to form from too much moisture.
See Air for Combustion and Ventilation, page
5. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor
content in the air.
For convenience and efficiency, install heater
• where there is easy access for operation, inspection and service
• in coldest part of room
An optional fan kit is available from your dealer.
See Accessories, page 26. If planning to use fan,
locate heater near an electrical outlet.
THERMOSTAT SENSING BULB
(Thermostat Models Only)
The thermostat sensing bulb has been placed
below the heater.
1. Place clamp on thermostat sensing bulb as
shown in Figure 5. Clamp is provided in
hardware package.
2. Snap clamp into upper mounting hole as shown
in Figure 5. Mounting hole is located on lower
left edge on back of heater. Make sure the
thermostat sensing bulb is pointing up.
Thermostat
Sensing
Bulb
Left
Side
Right
Side
Clamp
FLOOR
2" Minimum To
Top Surface
Of Carpeting,
Tile Or Other
Combustible
Material
Figure 5 - Attaching Thermostat Sensing
Bulb
Figure 4 - Mounting Clearances As
Viewed From Front of Heater
www.desatech.com
113052-01F
Installation
Continued
INSTALLING HEATER TO WALL
Mounting Bracket
Locate mounting bracket in heater carton. Remove
mounting bracket from heater carton.
Figure 6 - Mounting Bracket
Removing Front Panel Of Heater
1. Remove the four painted screws, two on each
side of front panel.
2. Pull bottom of front panel forward, then out.
16" remaining packaging
14"
3. Remove any
materials.
Marking Screw Locations
1. Tape mounting bracket to wall where heater
will be located. Make sure mounting bracket
is level.
WARNING: Maintain minimum clearances shown in Figure
8. If you can, ­ provide greater
clearances from floor and joining wall.
2. Mark screw locations on wall (see Figure 8).
Note: Only mark last hole on each end of
mounting bracket. Insert mounting screws
through these holes only.
3. Remove tape and mounting bracket from wall.
12"
Min.
Min.
Screw
Adjoining Wall
Adjoining Wall
Front Panel
25 3/4"
Only Insert Mounting
Optional
Screws Through Last
19 3/4"
Hole On Each End
Min.
14"
25 3/4"
Only Insert Mounting
Optional
Screws Through Last
19 3/4"
Hole On Each End
Min.
Floor
Floor
3 Plaque Heater
Methods For Attaching Mounting Bracket
To Wall
Only use last hole on each end of mounting bracket
to attach bracket to wall. These two holes are 14"
apart from their centers. Attach mounting bracket
to wall in one of two ways:
1. Attaching to wall stud
2. Attaching to wall anchor
Attaching to Wall Stud: This method provides the
strongest hold. Insert mounting screws through
mounting bracket and into wall studs.
Attaching to Wall Anchor: This method allows you
to attach mounting bracket to hollow walls (wall
areas between studs) or to solid walls (concrete
or masonry).
Decide which method better suits your needs.
Either method will provide a secure hold for the
mounting bracket.
113052-01F
1
M
14"
25 3/4"
Only Insert Mounting
Optional
Screws Through Last
19 3/4"
Hole On Each End
Min.
Floor
4 and 5 Plaque Heaters
Figure 8 - Mounting Bracket Clearances
Attaching Mounting Bracket To Wall
Note: Wall anchors, mounting screws and spacers
are in hardware package. The hardware package
is provided with heater.
www.desatech.com
Adjoining Wall
Figure 7 - Removing Front Panel Of
Heater
Adjoining Wall
16"
Min.
Installation
Horizontal Slots
Continued
Mounting
Bracket
(attached
to wall)
Attaching To Wall Stud Method
For attaching mounting bracket to wall studs
1. Drill holes at marked locations using 9/64"
drill bit.
2. Place mounting bracket onto wall. Line up last
hole on each end of bracket with holes drilled
in wall.
3. Insert mounting screws through bracket and
into wall studs.
4. Tighten screws until mounting bracket is
firmly fastened to wall studs.
Attaching To Wall Anchor Method
For attaching mounting bracket to hollow walls
(wall areas between studs) or solid walls (concrete
or masonry)
1. Drill holes at marked locations using 5/16"
drill bit. For solid walls (concrete or masonry),
drill at least 1" deep.
2. Fold wall anchor as shown in Figure 9.
3. Insert wall anchor (wings first) into hole. Tap
anchor flush to wall.
4. For thin walls (1/2" or less), insert red key
into wall anchor. Push red key to “pop” open
anchor wings. IMPORTANT: Do not hammer
key! For thick walls (over 1/2" thick) or solid
walls, do not pop open wings.
5. Place mounting bracket onto wall. Line up
last hole on each end of bracket with wall
anchors.
6. Insert mounting screws through bracket and
into wall anchors.
7. Tighten screws until mounting bracket is
firmly fastened to wall.
Figure 9 - Folding Figure 10 - Popping
Anchor
Open Anchor Wings
For Thin Walls
Stand-Out Tab
Figure 11 - Mounting Heater Onto
Mounting Bracket
Installing Bottom Mounting Screws
1. Locate two bottom mounting holes. These
holes are near bottom on back panel of heater
(see Figure 12).
2. Mark screw locations on wall.
3. Remove heater from mounting bracket.
4. If installing bottom mounting screws into
hollow or solid wall, install wall anchors.
Follow steps 1 through 4 under Attaching To
Wall Anchor Method.
If installing bottom mounting screw into wall
stud, drill holes at marked locations using 9/64"
drill bit.
5. Replace heater onto mounting bracket.
6. Place spacers between bottom mounting holes
and wall anchor or drilled hole.
7. Hold spacer in place with one hand. With other
hand, insert mounting screw through bottom
mounting hole and spacer. Place tip of screw
in opening of wall anchor or drilled hole.
8. Tighten both screws until heater is firmly
secured to wall. Do not over tighten.
Note: Do not replace front panel at this time.
Replace front panel after making gas connections and checking for leaks (see page 11).
Front View
Wall
Heater
Placing Heater On Mounting Bracket
1. Locate two horizontal slots on back panel of
heater.
2. Place heater onto mounting bracket. Slide
horizontal slots onto stand-out tabs on mounting bracket.
Spacer
Side View
Figure 12 - Installing Bottom Mounting
Screws
10
www.desatech.com
113052-01F
Installation
CONNECTING TO GAS SUPPLY
Continued
Mounting heater to floor
Mounting Base Feet to Heater
1. Lay heater cabinet on its back on a table
with the heater bottom overhanging the table
edge.
2. Align holes in base foot with mounting holes
on bottom of cabinet (see Figure 13).
3. Secure base foot to heater using sheet metal
screws.
4. Repeat for other side.
Mounting Base Feet to Floor (Where
required by local code)
1. Remove front cover (see Removing Front
Panel of Heater, page 9).
2. Position heater with base feet in desired location. Mark holes for drilling. Remove heater
with base.
3. For carpeted floors, make a small cut with a
sharp knife at marked locations prior to drilling. If mounting base to a wood floor, drill 1/8"
diameter hole, 3/4" deep. (Do not use anchors
in wood floors).
If mounting base to a concrete floor, drill with
1/4 inch diameter concrete drill bit, 13/8" into
floor. Insert anchors completely into holes.
4. Reposition heater with base feet over holes.
Secure base to floor with wood screws. See
Figure 13.
Wood
Screw
Base Foot
Sheet Metal Screw
Figure 13 - Installing Base Feet
WARNING: This appliance
requires a 3/8" NPT (National
Pipe Thread) inlet connection to
the pressure regulator.
WARNING: A qualified service
person must connect heater to gas
supply. Follow all local codes.
WARNING: For natural
gas, never connect heater to
private (non-utility) gas wells.
This gas is commonly known
as wellhead gas.
IMPORTANT: For natural gas, check gas line
pressure before connecting heater to gas line. Gas
line pressure must be no greater than 10.5" of water. If gas line pressure is higher, heater regulator
damage could occur.
CAUTION: For propane/LP
gas, never connect heater directly to the propane/LP supply.
This heater requires an external
regulator (not supplied). Install
the external regulator between the
heater and propane/LP supply.
For propane/LP gas, the installer must supply an
external regulator. The external regulator will
reduce incoming gas pressure. You must reduce
incoming gas pressure to between 11" and 14" of
water. If you do not reduce incoming gas pressure,
heater regulator damage could occur. Install the
external regulator with the vent pointing down
as shown in Figure 14. Pointing the vent down
protects it from freezing rain or sleet.
Propane/LP
External
Supply Tank
Regulator
Vent
Pointing
Down
Figure 14 - External Regulator With Vent
Pointing Down
113052-01F
www.desatech.com
11
Continued
CAUTION: Use only new,
black iron or steel pipe. Internally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
large enough diameter to allow
proper gas volume to heater. If
pipe is too small, undue loss of
volume will occur.
Typical Inlet Pipe Diameters
16,000 and 18,000 Btu/hr - 3/8" or greater
26,000 and 30,000 Btu/hr - 1/2" or greater
Installation must include equipment shutoff valve,
union and plugged 1/8" NPT tap. Locate NPT tap
within reach for test gauge hook up. NPT tap must
be upstream from heater (see Figure 15).
IMPORTANT: Install an equipment shutoff valve
in an accessible location. The equipment shutoff
valve is for turning on or shutting off the gas to
the appliance.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could result
in clogged heater valves.
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
Install sediment trap in supply line as shown in
Figure 15. Locate sediment trap where it is within
reach for cleaning. Locate sediment trap where
trapped matter is not likely to freeze. A sediment
trap traps moisture and contaminants. This keeps
them from going into heater controls. If sediment
trap is not installed or is installed wrong, heater
may not run properly.
IMPORTANT: Hold the pressure regulator with
wrench when connecting it to gas piping and/or
fittings. Do not over tighten pipe connection to
regulator. The regulator body could be damaged.
12
Pressure
Regulator
Regulator
Bracket
Heater
Cabinet
Test Gauge Connection*
Installation
Tee Joint
Reducer
Bushing to
1/8" NPT
1/8" NPT
Plug Tap
3/8" NPT
Pipe
Nipple
Ground
Joint
Union
Equipment
Shutoff Valve*
Natural Gas
3" From Gas
Min. Meter (7" W.C.
to 10.5" W.C.
Tee Pipe Cap
Pressure)
Joint Nipple
Propane/LP
From External
Sediment Trap
Regulator
(11" W.C. to 14"
W.C. Pressure)
Figure 15 - Gas Connection
* A CSA design-certified equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. Purchase the optional CSA
design-certified equipment shutoff valve from your
dealer. See Accessories, page 26.
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping
and connections, internal and
external to unit, for leaks after
installing or servicing. Correct
all leaks at once.
WARNING: Never use an
open flame to check for a leak.
Apply a noncorrosive leak detection fluid to all joints. Bubbles
forming show a leak. Correct all
leaks at once.
CAUTION: For propane/LP
gas, make sure external regulator has been installed between
propane/LP supply and heater.
See guidelines under Connecting to Gas Supply, page 11.
www.desatech.com
113052-01F
Installation
Continued
Pressure Testing Gas Supply
Piping System
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect appliance with its appliance main
gas valve (control valve) and equipment
shutoff valve from gas supply piping system.
Pressures in excess of 1/2 psig will damage
heater regulator.
2. Cap off open end of gas pipe where equipment
shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas
or using compressed air.
4. Check all joints of gas supply piping system.
Apply a noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff valve
to gas supply. Check reconnected fittings for
leaks.
Test Pressures Equal To or Less Than 1/2
PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 16).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve
located on or near gas meter for natural gas
or using compressed air.
3. Check all joints from gas meter for natural gas
(see Figure 17) or propane/LP supply tank for
propane/LP gas, to equipment shutoff valve
(see Figure 18). Apply a noncorrosive leak
detection fluid to all joints. Bubbles forming
show a leak.
4. Correct all leaks at once.
Pressure Testing Heater Gas
Connections
1. Open equipment shutoff valve (see Figure 16).
2. For natural gas open main gas valve located
on or near gas meter. For propane/LP gas open
propane/LP supply tank valve.
3. Make sure control knob of heater is in the OFF
position.
113052-01F
4. Check all joints from equipment shutoff valve
to thermostat gas valve (see Figure 17 or 18).
Apply a noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 14).
Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appliance, page 15).
8. Replace front panel.
Equipment
Shutoff Valve
Open
Closed
Figure 16 - Equipment Shutoff Valve
Thermostat Gas Valve
Gas
Meter
Equipment
Shutoff Valve
Figure 17 - Checking Gas Joints for
Natural Gas
Thermostat Gas Valve
Propane/LP
Supply Tank
Equipment
Shutoff
Valve
Figure 18 - Checking Gas Joints for
Propane/LP Gas
www.desatech.com
13
Operating Heater
FOR YOUR SAFETY READ
BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly,
a fire or ­ explosion may result
causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand,
don’t try to repair it, call a qualified service
technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information above.
2. Make sure equipment shutoff valve is fully
open.
3. Turn off any electric power to the appliance
if service is to be performed.
4. Turn control knob clockwise
to the
OFF position.
5. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you
smell gas, STOP! Follow “B” in the safety
information above. If you don’t smell gas, go
to the next step.
14
6. Thermostat Models: Turn control knob counterclockwise
to the PILOT position.
Press in control knob for five (5) seconds.
Manual Models: Press in and turn control knob
counterclockwise
to the PILOT position. Keep control knob pressed in for five (5)
seconds.
7. With control knob pressed in, push down and
release ignitor button. This will light pilot. The
pilot is attached to the front of burner.
Note: You may be running this heater for the
first time after hooking up to gas supply. If
so, the control knob may need to be pressed
in for 30 seconds or more. This will allow air
to bleed from the gas system.
If needed, keep pressing ignitor button until
pilot lights. If ignitor does not light pilot, refer
to Troubleshooting, page 18 or contact a qualified service person or gas supplier for repairs.
Until repairs are made, light pilot with match.
See Manual Lighting Procedure, page 15.
8. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
• If control knob does not pop up when released, contact a qualified service person or
gas supplier for repairs.
Note: If pilot goes out, repeat steps 4 thru 7.
Thermostat models have a safety interlock
system. Wait one (1) minute before lighting
pilot again.
9. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Manual control heaters should
be used in locked positions.
WARNING: Always operate
manual control heaters at the
locked positions. Operation
between these positions may
create a possible health hazard
if used in a poorly ventilated
room. Read owner’s manual for
complete instructions.
CAUTION: Do not try to adjust heating levels by using the
equipment shutoff valve.
www.desatech.com
113052-01F
MANUAL LIGHTING
PROCEDURE
Operating Heater
Continued
Control Knob
Ignitor Button
OFF
Figure 19 - Control Knob In The OFF
Position (Manual Controlled Models)
Ignitor Button
Control Knob
1. Remove front panel (see page 9).
2. Follow steps 1 through 7 under Lighting
Instructions, page 14.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow step 9, under Lighting Instructions, page 14.
5. Replace front panel.
OFF
PILO
T
THERMOSTAT
OPERATION
Figure 20 - Control Knob In The OFF
Position (Thermostat Models)
Thermocouple
Ignitor Electrode
Pilot
Burner
Figure 21 - Pilot
The thermostatic control used on these models
differs from standard thermostats. Standard thermostats simply turn on and off the burner. The
thermostat used on this heater senses the room
temperature. At times the room may exceed the
set temperature. If so, the burner will shut off. The
burner will cycle back on when room temperature
drops below the set temperature. The control knob
can be set to any heating level between 1 and 5.
All plaques will turn off and on.
Note: The thermostat sensing bulb measures the
temperature of air near the heater cabinet. This
may not always agree with room temperature
(depending on housing construction, installation
location, room size, open air temperatures, etc.)
Frequent use of your heater will let you determine
your own comfort levels.
TO SELECT
HEATING LEVEL
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the
OFF position.
2. Turn off any electric power to the appliance
if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise
to the PILOT
position.
WARNING: When running
heater, set control knob at LOW,
MEDIUM or HIGH locked positions. Never set control knob
between locked positions. Poor
combustion and higher levels of
carbon monoxide may result.
CAUTION: Do not try to adjust heating levels by using the
equipment shutoff valve.
113052-01F
www.desatech.com
15
Operating Heater
Continued
Slightly press in control knob and turn counterclockwise
to the LOW, MED or HI positions (see Figure 22 or 23).
IMPORTANT: Release downward pressure while
turning control knob. Control knob will lock at the
desired position.
Control
Knob
16,000 &
18,000 Btu/Hr
26,000 &
30,000 Btu/Hr
LOW
• turn heater off (see To Turn Off Gas to Appliance, page 15)
• see Troubleshooting, page 18
Note: The pilot flame on natural gas units will
have a slight curve, but flame should be blue and
have no yellow or orange color.
Blue Flame
Thermocouple
Pilot Burner
Figure 24 - Correct Pilot Flame Pattern
Yellow Flame
MED
Thermocouple
Pilot Burner
HI
Figure 25 - Incorrect Pilot Flame Pattern
OFF
Figure 22 - Burner Patterns for Manual
Controlled Models
Control
Knob
16,000 &
18,000 Btu/Hr
26,000 &
30,000 Btu/Hr
BURNER FLAME PATTERN
Figure 26 shows a correct burner flame pattern. Figure 27 shows an incorrect burner flame pattern.
If burner flame pattern is incorrect, as shown in
Figure 27
• turn heater off (see To Turn Off Gas to Appliance, page 15)
• see Troubleshooting, page 18
Figure 23 - Burner Patterns for
Thermostat Models
Inspecting Heater
Check pilot flame pattern and burner flame pattern often.
Figure 26 - Correct Burner Flame Pattern
PILOT FLAME PATTERN
Figure 24 shows a correct pilot flame pattern.
Figure 25 shows an incorrect pilot flame pattern.
The incorrect pilot flame is not touching the
thermocouple. This will cause the thermocouple
to cool. When the thermocouple cools, the heater
will shut down.
If pilot flame pattern is incorrect, as shown in
Figure 25
16
Figure 27 - Incorrect Burner Flame
Pattern
www.desatech.com
113052-01F
Cleaning and
Maintenance
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner and circulating air ­passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a
qualified service person. Heater
may need more frequent cleaning due to excessive lint from
carpeting, bedding material, pet
hair, etc.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result in
sooting and property damage.
ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized air or small,
soft bristled brush to clean.
Burner Pilot Air Inlet
The primary air inlet holes allow the proper
amount of air to mix with the gas. This provides a
clean burning flame. Keep these holes clear of dust,
dirt and lint. Clean these air inlet holes prior to each
heating season. Blocked air holes will create soot.
We recommend that you clean the unit every three
months during operation and have heater inspected
yearly by a qualified service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust and
dirt. To clean these parts we recommend using
compressed air no greater than 30 PSI. Your local
computer store, hardware store or home center may
carry compressed air in a can. If using compressed
air in a can, please follow the directions on the can.
If you don’t follow directions on the can, you could
damage the pilot assembly.
113052-01F
1. Shut off the unit, including the pilot. Allow
the unit to cool for at least thirty minutes.
2. Inspect burner, pilot for dust and dirt.
3. Blow air through the ports/slots and holes in
the burner.
4. Never insert objects into the pilot tube.
Clean the pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet about two
inches from where the pilot flame comes out of
the pilot assembly (see Figure 28). With the unit
off, lightly blow air through the air inlet. You may
blow through a drinking straw if compressed air
is not available.
Pilot Assembly
Pilot Air Inlet
Figure 28 - Pilot Air Inlet
CABINET
Air Passageways
Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap and
water mixture. Wipe the cabinet to remove dust.
www.desatech.com
17
Troubleshooting
WARNING: Turn off and unplug heater and let cool before servicing.
Only a qualified service person should service and repair heater.
CAUTION: Never use a wire, needle or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed
in, there is no spark at ODS/
pilot
1. Ignitor electrode positioned
wrong
2. Ignitor electrode broken
3. Ignitor electrode not connected to ignitor cable
4. Ignitor cable pinched or wet
1. Replace pilot assembly
5. Broken ignitor cable
6. Bad ignitor
7. Battery not installed, battery
power low or battery not installed correctly
When ignitor button is pressed
in, there is a spark at ODS/Pilot
but no ignition
1. Gas supply turned off or equipment shutoff valve closed
2. Control knob not fully pressed
in while pressing ignitor button
3. Air in gas lines when installed
4. Depleted gas supply (propane/
LP gas)
5. ODS/pilot is clogged
6. Gas regulator setting is not
correct
7. Control knob is not in pilot
position
18
www.desatech.com
2. Replace pilot assembly
3. Reconnect ignitor cable
4. Free ignitor cable if pinched
by any metal or tubing. Keep
ignitor cable dry
5. Replace ignitor cable
6. Replace ignitor
7. Install new alkaline battery
in electronic ignitor. Verify
battery is installed correctly
1. Turn on gas supply or open
equipment shutoff valve
2. Turn to PILOT position. Fully
press in control knob while
pressing ignitor button
3. Continue holding down control knob. Repeat igniting operation until air is removed
4. Contact local propane/LP gas
company
5. Clean ODS/pilot (see Cleaning
and Maintenance, page 17) or
replace ODS/pilot assembly
6. Replace gas regulator
7. Turn control knob to pilot
position
113052-01F
TROUBLESHOOTING
OBSERVED PROBLEM
ODS/pilot lights but flame
goes out when control knob is
released
Burner(s) does not light after
ODS/pilot is lit
Continued
POSSIBLE CAUSE
1. Control knob not fully pressed in
2. Control knob not pressed in
long enough
3. Equipment shutoff valve not
fully open
4. Thermocouple connection
loose at control valve
5. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing
pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
6. Thermocouple damaged
7. Control valve damaged
8. Safety interlock system has
been triggered (thermostat
models only)
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob pressed in 30 seconds
3. Fully open equipment shutoff
valve
4. Hand tighten until snug, then
tighten 1/4 turn more
5. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Cleaning and Maintenance,
page 17) or replace ODS/pilot
assembly
1. Burner orifice(s) is clogged
1. Clean burner orifice(s) (see
Cleaning and Maintenance,
page 17) or replace burner
orifice(s)
2. Contact local natural or propane/LP gas company
2. Inlet gas pressure is too low
Delayed ignition of burner(s)
1. Manifold pressure is too low
2. Burner orifice(s) is clogged
Burner backfiring during combustion
1. Burner orifice(s) is clogged or
damaged
2. Burner damaged
3. Gas regulator defective
Burner plaque(s) does not
glow
Slight smoke or odor during
initial operation
113052-01F
REMEDY
1. Plaque damaged
2. Inlet gas pressure is too low
6. Replace pilot assembly
7. Replace control valve
8. Wait one minute for safety interlock system to reset. Repeat
ignition operation
1. Contact local natural or propane/LP gas company
2. Clean burner orifice(s) (see
Cleaning and Maintenance,
page 17) or replace burner
orifice(s)
1. Clean burner orifice(s) (see
Cleaning and Maintenance,
page 17) or replace burner
orifice(s)
2. Replace burner
3. Replace gas regulator
3. Control knob set between
locked positions
1. Replace burner
2. Contact local natural or propane/LP gas company
3. Turn control knob until it
locks at desired setting
1. Residues from manufacturing
processes
1. Problem will stop after a few
hours of operation
www.desatech.com
19
TROUBLESHOOTING
Continued
WARNING: If you smell gas
Shut off gas supply.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
•
•
•
•
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies,
paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes.
These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking noise just after burner is lit
or shut off
1. Metal expanding while heating
or contracting while cooling
1. This is normal with most heaters. If noise is excessive, contact
qualified service person
White powder residue forming
within burner box or on adjacent
walls or furniture
1. When heated, vapors from
furniture polish, wax, carpet
cleaner, etc., may turn into
white powder residue
1. Turn heater off when using
furniture polish, wax, carpet
cleaners or similar products
Heater produces unwanted
odors
1. Heater burning vapors from
paint, hair spray, glues, etc. See
IMPORTANT statement above
2. Low fuel supply (propane/LP gas)
3. Gas leak. See Warning
statement at top of page
1. Ventilate room. Stop using
odor causing products while
heater is running
2. Refill supply tank
3. Locate and correct all leaks
(see Checking Gas Connections, page 12)
Heater shuts off in use (ODS
operates)
1. Not enough fresh air is available
2. Low line pressure
1. Open window and/or door for
ventilation
2. Contact local natural or propane/LP gas company
3. Clean ODS/pilot (see Cleaning
and Maintenance, page 17)
3. O D S / p i l o t i s p a r t i a l l y
clogged
Gas odor even when control
knob is in OFF position
1. Gas leak. See Warning
statement at top of page
2. Control valve defective
1. Locate and correct all leaks
(see Checking Gas Connections, page 12)
2. Replace control valve
Gas odor during combustion
1. Foreign matter between control valve and burner
2. Gas leak. See Warning
statement at top of page
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connections, page 12)
Moisture/condensation noticed
on windows
1. Not enough combustion/ventilation air
1. Refer to Air for Combustion
and Ventilation requirements
(page 5)
20
www.desatech.com
113052-01F
Specifications
VP16A, VP16TA
VN18A, VN18TA
VP26A, VP26TA
VN30A, VN30TA
•
•
•
•
•
6,000/11,000/16,000 Btu/hr (variable)
Propane/LP Gas Only
Electronic Ignition
Pressure Regulator Setting: 8" W.C.
Inlet Gas Pressure* (in. of water):
Maximum - 14", Minimum - 11"
•
•
•
•
•
6,000/16,000/26,000 Btu/hr (variable)
Propane/LP Gas Only
Electronic Ignition
Pressure Regulator Setting: 8" W.C.
Inlet Gas Pressure* (in. of water):
Maximum - 14", Minimum - 11"
* For purposes of input adjustment.
113052-01F
•
•
•
•
•
6,600/12,000/18,000 Btu/hr (variable)
Natural Gas Only
Electronic Ignition
Pressure Regulator Setting: 6" W.C.
Inlet Gas Pressure* (in. of water):
Maximum - 10.5", Minimum - 7"
•
•
•
•
•
6,600/18,000/30,000 Btu/hr (variable)
Natural Gas Only
Electronic Ignition
Pressure Regulator Setting: 6" W.C.
Inlet Gas Pressure* (in. of water):
Maximum - 10.5", Minimum - 7"
* For purposes of input adjustment.
www.desatech.com
21
Illustrated Parts Breakdown
Cabinet body Models
vp16A, vn18A, vp26A, vn30A, VP16TA, VN18TA, VP26TA and VN30TA
5
17
7
15
14
11
6
See Pages
24 and 25
4
8
16
Replacement
may vary from
grill shown
See Pages
24 and 25
9
10
13
12
3
2
1
22
AAA
Battery
Negative
UP
www.desatech.com
Install Battery
According To
This Illustration
(Actual ignitor
may vary from
illustration)
113052-01F
AA
Battery
Positive
UP
Parts List
KEY
NO. PART NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
107672-01
107675-01
103476-01
103476-02
104635-01
104635-03
107894-12
107894-13
**
111435-01
099066-02
098271-11
098462-01
098325-01
098354-03
099415-18
099415-19
104819-02
098522-24
102394-02
103256-02
107660-01
107660-03
109303-03
109303-04
VP1
6A
VP1
6TA
VN1
8A
VN1
8TA
VP2
6A
VP2
6TA
VN3
0A
VN3
0TA
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions
listed under Replacement Parts on page 26 of this manual.
DESCRIPTION
QTY.
Front Panel
Front Panel
Grill Guard
Grill Guard
Apron
Apron
Reflector Assembly
Reflector Assembly
Cabinet Back Panel
Electronic Ignitor
Mounting Bracket
Ignitor Cable
Control Rod Assembly
Roll Pin
Control Knob
Gas Regulator
Gas Regulator
Regulator Bracket
Thermostat Gas Valve
Thermostat Valve Mounting Bracket
Inlet Tube
Inlet Tube
Inlet Tube
Baffle
Baffle
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
PARTS AVAILABLE - NOT SHOWN
100642-03 Hardware Assembly
116360-01 Lighting/Warning Tag (English)
116360-02 Lighting/Warning Tag (Spanish)
105345-01 Cable Tie
107888-01 Control Position Label
GA4550
Base Foot
** Not a field replaceable part.
113052-01F
www.desatech.com
•
•
•
•
•
•
•
•
•
•
•
•
1
1
1
1
1
1
23
ILLUSTRATED PARTS BREAKDOWN and parts List
Burner Assembly Models vp16A, vn18A, vp16TA and vn18TA
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions
listed under Replacement Parts on page 26 of this manual.
5
5
6
8
7
1
1
2
2
3
7
6
12
4
43
11
13
4
Burner Assembly
VP16TA and VN18TA
10
9
1
4
2
KEY
NO. PART NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
24
110803-02
110803-03
110186-01
098200-03
099387-11
105051-01
099218-08
098508-01
099056-01
099056-02
099056-24
099056-25
103844-01
107660-01
103352-03
103352-04
104818-03
DESCRIPTION
ODS/Pilot
ODS/Pilot
Thermocouple Kit
Control Valve Bracket
Pilot Tubing
Pilot Tubing
Burner
Valve Retainer Nut
Injector - Plaque A
Injector - Plaque A
Injector - Plaque B
Injector - Plaque B
Control Valve
Inlet Tubing
Tubing-Valve to Plaque A
Tubing-Valve to Plaque B
Outlet Tubing
www.desatech.com
VP1
ODS/Pilot
6A
VN1
8A
VP1
6TA
VN1
8TA
Burner Assembly VP16A and VN18A
QTY.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
113052-01F
ILLUSTRATED PARTS BREAKDOWN and parts List
Burner Assembly Models vp26A, vn30A, VP26TA and VN30TA
This list contains replaceable parts used in your heater. When ordering parts, follow the instructions
listed under Replacement Parts on page 26 of this manual.
5
5
1
1
76
6
7
2
2
8
87
76
10
3
7
11
12
12
4
3
4
13
10
14
4
9
Burner Assembly VP26TA and VN30TA
4
1
1
ODS/Pilot
2
3
4
5
6
7
8
9
10
11
12
13
14
113052-01F
110803-02
110803-03
110186-01
098200-03
099387-03
105050-02
099218-09
098508-01
099056-24
099056-25
099056-01
099056-02
100747-01
107660-03
103353-04
103353-05
103353-06
104818-04
DESCRIPTION
ODS/Pilot
ODS/Pilot
Thermocouple Kit
Control Valve Bracket
Pilot Tubing
Pilot Tubing
Burner
Valve Retainer Nut
Injector - Plaque A and C
Injector - Plaque A and C
Injector - Plaque B
Injector - Plaque B
Control Valve
Inlet Tubing
Tubing-Valve to Plaque A
Tubing-Valve to Plaque B
Tubing-Valve to Plaque C
Outlet Tubing
www.desatech.com
VP2
KEY
NO. PART NO.
6A
VN3
0A
VP2
6TA
VN3
0TA
Burner Assembly VP26A and VN30A
2
QTY.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1
1
1
1
1
1
1
1
1-2
1-2
1
1
1
1
1
1
1
1
25
Replacement Parts
Note: Use only original replacement parts. This
will protect your warranty coverage for parts
replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA Heating Products’ Technical Service
Department at 1-866-672-6040.
When calling DESA Heating Products, have
ready
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the
factory.
Parts Not Under Warranty
Contact authorized dealers of this product. If they
can’t supply original replacement part(s), either
contact your nearest Parts Central (see page 27)
or call DESA Heating Products at 1-866-672-6040
for referral information.
When calling DESA Heating Products, have
ready
• model number of your heater
• the replacement part number
Service Hints
When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.
Accessories
Purchase these heater accessories from your local
dealer. If they can not supply these accessories, either
contact your nearest Parts Central (see page 27) or
call DESA Heating Products at 1-866-672-6040 for
referral information. You can also write to the address
listed on the back page of this manual.
equipment SHUTOFF VALVE
GA5010
For all models. Equipment shutoff valve with
1/8" NPT tap.
FAN KITS - GA3250T
For all models. Provides better heat distribution.
Makes heater more efficient. Complete installation
and operating instructions included.
Thermostatically-controlled, blower turns itself on
and off as required.
Service Publications
You can purchase a service manual from the address
listed on the back page of this manual. Send a check
for $5.00 payable to DESA Heating Products.
Technical Service
You may have further questions about installation,
operation or troubleshooting. If so, contact DESA
Heating Products’ Technical Service Department
at 1-866-672-6040. When calling please have your
model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ technical service web site at www.desatech.com.
26
www.desatech.com
113052-01F
Parts Central
These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by
providing original replacement parts and accessories.
Tool & Equipment Co.
5 Manila Ave
Hamden, CT 06514-0322
1-800-397-7553
203-248-7553
Portable Heater Parts
342 N. County Rd. 400 East
Valparaiso, IN 46383-9704
219-462-7441
1-888-619-7060
www.portableheaterparts.com
[email protected]
[email protected]
FBD
1349 Adams Street
Bowling Green, KY 42103-3414
270-846-1199
1-800-654-8534
Fax: 1-800-846-0090
[email protected]
Master Parts Dist.
1251 Mound Ave. NW
Grand Rapids, MI 49504-2672
616-791-0505
1-800-446-1446
www.nbmc.com
113052-01F
Washer Equipment Co.
1715 Main Street
Kansas City, MO 64108-2195
KS, MO, AR
816-842-3911
www.washerparts.com
East Coast Energy
10 East Route 36
W. Long Branch, NJ 07764-1542
732-870-8809
1-800-755-8809
www.njplaza.com/ecep
21st Century
2950 Fretz Valley Road
Perkasie, PA 18944-4034
215-795-0400
800-325-4828
Laporte’s Parts & Service
2444 N. 5th Street
Hartsville, SC 29550-7704
843-332-0191
Parts Department
Cans Unlimited
P.O. Box 645
Taylor, SC 29687-0013
803-879-3009
1-800-845-5301
[email protected]
www.desatech.com
27
Warranty Information
KEEP THIS WARRANTY
Model
Serial No.
Date of Purchase
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our
standard written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTIES FOR NEW AND FACTORY
RECONDITIONED PRODUCTS
New Products: DESA Heating Products warrants this heater and any parts thereof, to be free of defects in materials
and workmanship for four (4) year from the date of first purchase, when operated and maintained in accordance
with the manufacturer's instructions. These warranties are extended only to the original retail purchaser, when
proof of purchase is provided.
Factory Reconditioned Heaters: DESA Heating Products warrants this factory reconditioned heater and any parts
thereof, to be free of defects in materials and workmanship for thirty (30) days from the date of first purchase,
when operated and maintained in accordance with the manufacturer's instructions. These warranties are extended
only to the original retail purchaser, when proof of purchase is provided.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required
to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Heating
Products Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product
and/or DESA Heating Products who will provide original factory replacement parts. Failure to use original factory
replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with
all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts
that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by
improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to
repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE
OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED
WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR
(4) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING
PRODUCTS’ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND
DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER
INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of
incidental or consequential damages, so the above limitation on implied warranties or exclusion or limitation on
damages may not apply to you.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state.
For information about this warranty write:
P.O. Box 90004
Bowling Green, KY 42102-9004
www.desatech.com
Patent Pending
113052 01
NOT A UPC
113052-01