MultiTech MTCDTIP-L4N1-267A-915 IP67 Conduit Software Guide
Реклама
Реклама
mPower
TM
Edge Intelligence
Conduit AEP Software Guide
MPOWER EDGE INTELLIGENCE SOFTWARE GUIDE mPower Edge Intelligence Software Guide
Models: MTCDT, MTCDTIP, MTCAP
Part Number: S000727 Version: 5.1
Copyright
This publication may not be reproduced, in whole or in part, without the specific and express prior written permission signed by an executive officer of
Multi-Tech Systems, Inc. All rights reserved.
Copyright © 2019 by Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representations or warranties, whether express, implied or by estoppels, with respect to the content, information, material and recommendations herein and specifically disclaims any implied warranties of merchantability, fitness for any particular purpose and noninfringement.
Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of
Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
Legal Notices
The MultiTech products are not designed, manufactured or intended for use, and should not be used, or sold or re-sold for use, in connection with applications requiring fail-safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or death, significant property damage, or serious physical or environmental damage. Examples of such use include life support machines or other life preserving medical devices or systems, air traffic control or aircraft navigation or communications systems, control equipment for nuclear facilities, or missile, nuclear, biological or chemical weapons or other military applications (“Restricted Applications”). Use of the products in such Restricted
Applications is at the user’s sole risk and liability.
MULTITECH DOES NOT WARRANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE
UNINTERRUPTED, TIMELY, SECURE OR ERROR FREE, NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR
COMMUNICATIONS NETWORK. MULTITECH WILL HAVE NO LIABILITY FOR ANY LOSSES, DAMAGES, OBLIGATIONS, PENALTIES, DEFICIENCIES, LIABILITIES,
COSTS OR EXPENSES (INCLUDING WITHOUT LIMITATION REASONABLE ATTORNEYS FEES) RELATED TO TEMPORARY INABILITY TO ACCESS A CELLULAR
COMMUNICATIONS NETWORK USING THE PRODUCTS.
Trademarks and Registered Trademarks
MultiTech, the MultiTech logo, DeviceHQ, xDot, and MultiConnect and Conduit are registered trademarks and mPower mCard and mDot are trademarks of
Multi-Tech Systems, Inc. All other products and technologies are the trademarks or registered trademarks of their respective holders.
Contacting MultiTech
Knowledge Base
The Knowledge Base provides immediate access to support information and resolutions for all MultiTech products. Visit http://www.multitech.com/kb.go
.
Support Portal
To create an account and submit a support case directly to our technical support team, visit: https://support.multitech.com
.
Support
Business Hours: M-F, 8am to 5pm CT
Country
Europe, Middle East, Africa:
U.S., Canada, all others:
By Email [email protected]
By Phone
+(44) 118 959 7774
(800) 972-2439 or (763) 717-5863
Warranty
To read the warranty statement for your product, visit https://www.multitech.com/legal/warranty . For other warranty options, visit www.multitech.com/es.go
.
World Headquarters
Multi-Tech Systems, Inc.
2205 Woodale Drive, Mounds View, MN 55112
Phone: (800) 328-9717 or (763) 785-3500
Fax (763) 785-9874
2 mPower TM Edge Intelligence Conduit AEP Software Guide
CONTENTS
Contents
mPower TM Edge Intelligence Conduit AEP Software Guide 3
CONTENTS
4 mPower TM Edge Intelligence Conduit AEP Software Guide
CONTENTS
mPower TM Edge Intelligence Conduit AEP Software Guide 5
CONTENTS
6 mPower TM Edge Intelligence Conduit AEP Software Guide
PRODUCT OVERVIEW
Chapter 1 – Product Overview
About mPower Edge Intelligence
This guide reviews the mPower Edge Intelligence software for Conduit devices.
For hardware details, refer to the appropriate hardware guide. Use your device to provide secure data communication between many types of devices that use legacy and the latest communication technologies.
Some device models support (varies with model-refer to your specific hardware guide for details):
Bluetooth communication to devices with this technology
Wi-Fi communication to devices with this technology
GPS capability
Diversity
What's New in This Release
Manual version
5.0
5.1
Update description
Convergence of MTR and AEP Conduit software: Network Interfaces, Global DNS, and various security features
IPv6 support, Password Complexity, Reverse SSH, and LoRaWAN: Spectral Scan.
mPower TM Edge Intelligence Conduit AEP Software Guide 7
USING THE WIZARD TO CONFIGURE YOUR DEVICE
8
Chapter 2 – Using the Wizard to Configure Your
Device
First-Time Setup
Setting Up Your Device using Setup Wizard (After Choosing Reset and Factory Default Settings)
If you need to change the mode of your device, this is the only way to do so. This section is not available through the device management software.
Other than when you first power up the device, you must configure the device to factory default settings, reset it and then, access it through the default 192.168.2.1 IP address to see the first-time setup. To reset the device to factory default settings, go to Administration > Save/Restore > Reset to Factory Default Configuration and click the Reset button. This wizard helps you configure the main features of your device for initial setup.
Depending on the mode, your proceeding options and fields differ (see For Network Router Mode below for the mode's proceeding steps). Here are the steps for first-time setup:
1.
Upon power up for the first time or after you set factory default settings, the device goes into commissioning mode. The system requires you to set up an admin user. Enter your desired username and click OK .
2.
Enter a desired password for the admin user and click OK . This password must be of sufficient length and strength (with a mix of character classes such as letters, numbers, and symbols). Enter the password again to confirm. Click OK .
3.
Log into your device using your new username and password.
4.
On the first page, the mode option lets you set up the device as a Network Router device.
a.
The Network Router mode is the default and establishes the device as a cellular network router.
b.
Click Next .
For Network Router Mode:
1.
Configure Call Home a.
Check Enabled.
(You must have an existing DeviceHQ™ account.) b.
Click the Call Home button to activate Call Home (which enables the device to call home for configuration files, firmware updates, custom applications, and adds your DeviceHQ account key to the device).
NOTE: Clicking the Call Home button, results in the device being reset to factory defaults.
c.
Click Next.
2.
Set the date, time, and time zone.
a.
Enter the desired Date .
b.
Enter the desired Time .
c.
Select the Time Zone in which the device operates.
d.
Click Next .
3.
Configure LAN network interfaces Eth0 and Br0. Enter the device address and network information
(Network Router mode only): mPower TM Edge Intelligence Conduit AEP Software Guide
USING THE WIZARD TO CONFIGURE YOUR DEVICE a.
In the Network Interface Configuration – eth0 section, leave the eth0 assigned to the bridge br0 , or unassign eth0 from bridge and enter network settings for the eth0 interface IPv4 Address and
Mask.
b.
In the Network Interface Configuration – br0 section, enter network settings for the br0 interface -
IPv4 Address and Mask .
4.
Configure your device's PPP .
a.
To use PPP, check Enable . When enabled, your device functions as a router.
b.
Check Diversity to enable the use of two cellular antennas for better performance. (For devices that use two antennas, Diversity is enabled by default. See Installing the Router in your User Guide for more details).
c.
To enable the dial-on-demand feature, check Dial-on-Demand . This indicates to the device to bring up the PPP connection when there is outgoing IP traffic, and take down the PPP connection after a given idle timeout.
d.
Enter the APN (Access Point Name). The APN is assigned by your wireless service provider. (This field is not available on all models.) e.
Click Next .
5.
Set up PPP Authentication : a.
Select the authentication protocol Type used to negotiate with the remote peer: PAP, CHAP, or PAP-
CHAP . The default value is NONE .
b.
Enter the Username with which the remote peer authenticates. Optional. Username is limited to 60 characters.
c.
Enter the Password with which the remote peer authenticates. Optional. Password is limited to 60 characters.
6.
Set up Remote Management: a.
Check Enabled to configure the device to check in at the next scheduled check-in time.
b.
Check SSL Enabled to activate SSL on the annex protocol.
c.
Server Name for DeviceHQ is provided.
d.
Server Port for DeviceHQ is provided.
e.
App Store URL for DeviceHQ is provided.
f.
Enter your DeviceHQ Account Key . ( NOTE: You must already have a DeviceHQ account.) g.
Click Next.
7.
Configure HTTP/HTTPS Access .
a.
In the HTTP Redirect to HTTPS panel define how the device handles HTTP traffic. Check Enabled to enable HTTP and redirect to HTTPS.
b.
Configure HTTP Port . By default, 80.
c.
Check Via LAN (enabled by default) to allow traffic from local area network.
d.
Check Via WAN (disabled by default) to allow traffic from the wide area network.
e.
In the HTTPS panel, define how the device handles secure HTTP traffic.
f.
Check Via WAN to allow traffic from the wide area network. Note: HTTPS traffic via LAN is enabled by default and cannot be changed.
g.
Configure HTTPS Port . By default, 443.
mPower TM Edge Intelligence Conduit AEP Software Guide 9
USING THE WIZARD TO CONFIGURE YOUR DEVICE
8.
Set up Bootloader Protection by setting a u-boot password.
a.
Enter a password and click Enable . The password will be set immediately.
b.
To change the password, enter a new password and click Change Password .
c.
To disable the password, click Disable .
9.
Click Finish .
10.
To save your changes, click Save and Restart .
Note : The Bootloader Protection settings depend on the previous u-boot configuration and are preserved when device is reset to factory defaults.
10 mPower TM Edge Intelligence Conduit AEP Software Guide
HOME
Chapter 3 – Home
Device Information
This page provides a high-level view of the device. It shows the configuration for one or more network interfaces including a cellular interface. Click Home to display the following information:
1.
Device :
Model Number : The MultiConnect® Conduit model ID.
Serial Number : The MultiTech device ID.
IMEI : International Mobile Station Equipment Identity.
Firmware : mPower Edge Intelligence firmware version.
Current Time : Current date and time of the device. For information on setting the date and time, go to Setup > Time Configuration .
Up Time : Amount of time the device has been continuously operating.
WAN Transport : Current transport for IP traffic leaving the LAN. If two WAN interfaces are configured for use (Wi-Fi and cellular), the current WAN will be set based on the WAN configurations at Setup > WAN Configuration .
Current DNS : the actual DNS IP addresses that are used by the current WAN.
GeoPosition : the GPS coordinates of the device (provided a GPS satellite fix is acquired).
2.
LAN ( LAN network interfaces, br0, eth0, eth1, eth2, and wlan1 ):
Bridge ( br0 )
MAC Address : Media Access Control Address used to uniquely identify the devices LAN
Ethernet interface.
IPv4 Address : IP address of this device. To configure the IP address, go to Setup >
Network Interfaces Configuration .
Mask : Network mask of the bridge ( br0 ). To configure the network mask, go to Setup >
Network Interfaces Configuration .
DHCP State : Current state of the DHCP server configured for the bridge (br0). To configure, go to Setup > DHCP Configuration .
Interfaces: lists all the interfaces added to the bridge (br0).
Ethernet (eth0, eth1, and eth2)
Bridge: specifies if the network interface is added into the bridge ( br0 ).
MAC Address : Media Access Control Address used to uniquely identify the devices LAN
Ethernet interface.
IPv4 Address : LAN IP address of the Ethernet interface. To configure the IP address, go
Setup > Network Interfaces Configuration .
Mask : Network mask of the Ethernet interface. To configure the network mask, go to
Setup > Network Interfaces Configuration.
DHCP State : Current state of the DHCP server configured for the bridge ( br0 ). To configure, go to Setup > DHCP Configuration .
mPower TM Edge Intelligence Conduit AEP Software Guide 11
HOME
12
Lease Range : Current DHCP lease range of the Ethernet interface. To configure, go to Setup
> DHCP Configuration .
DHCP State : Current state of this device's DHCP server. To configure go to Setup > DHCP
Configuration .
Lease Range : Current DHCP lease range of this device's DHCP server. To configure go to
Setup > DHCP Configuration .
Wi-Fi Access Point (wlan1) :
State : Current state of the Access Point. To configure go to Wireless > Wi-Fi Access Point .
Bridge : specifies if the network interface is added into the bridge ( br0 ).
MAC Address : Media Access Control Address used to uniquely identify the devices LAN
Ethernet interface.
IPv4 Address : LAN IP address of the wlan1 interface. To configure the IP address, go Setup
> Network Interfaces Configuration .
Mask : Network mask of the Access Point (wlan1). To configure the network mask, go to
Setup > Network Interfaces Configuration .
DHCP State : Current state of the DHCP server configured for the wlan1 network interface.
To configure, go to Setup > DHCP Configuration .
SSID : the Service Set Identifier (SSID) for this device's Wi-Fi Access Point. For configuration go to Wireless > Wi-Fi Access Point .
Security : the current security protocol of this device's Wi-Fi Access Point. To configure go to
Wireless > Wi-Fi Access Point .
3.
Bluetooth Classic
State : Current state of the Bluetooth link. To configure go to Wireless > Bluetooth-IP .
MAC Address : Media Access Control Address used to uniquely identify the Bluetooth interface.
Device Name : Name of Bluetooth device configured to link to. For configuration go to
Wireless > Bluetooth-IP.
Device MAC : Media Access Control Address of the Bluetooth device configured to link to. To configure go to Wireless > Bluetooth-IP .
4.
WAN (WAN network interfaces, ppp0 , wlan0, eth0, eth1, and eth2 ):
Cellular (ppp0) :
State: Current state of the cellular PPP link.
Connection Mode: PPP or WWAN (only visible on LTE devices)
Mode: PPP or P PP-Addresses Only .
Protocol Support : Choose from IPv4 or IPv6 . If you choose IPv6 , also enter the Connect
Timeout .
Signal : Current signal strength of the cellular link. Mouse hover provides dBm value.
Connected : Total time connected for the current PPP session.
IPv4 Address : Current cellular WAN IP address issued to this device by the cellular carrier.
DNS : DNS IP addresses retrieved from the cellular network or configured by user in the
Setup > Network Interfaces Configuration.
mPower TM Edge Intelligence Conduit AEP Software Guide
HOME
Roaming : Indicates whether or not this device's cellular link is currently connected to its home network.
Phone number : Device's cellular phone number also known as Mobile Directory
Number (MDN). This field is blank if the MDN is not stored in the SIM card.
Tower : Tower ID of the cellular tower currently providing cellular service to this device.
Ethernet (eth0, eth1, and eth2):
Mode : Static, DHCP Client or DHCP Client – Addresses Only
MAC Address: Media Access Control Address used to uniquely identify the devices LAN
Ethernet interface.
IPv4 Address: IP address of the Ethernet interface. To configure the IP address, go to
Setup > Network Interfaces Configuration .
Mask: Network mask of the network to which the device is currently connected.
Gateway: Gateway IP address of the network to which the device is currently connected.
DNS: DNS IP addresses retrieved from the cellular network or configured by user in the
Setup > Network Interfaces Configuration.
Wi-Fi (wlan0) :
State : Current state of the Wi-Fi
Mode : DHCP Client or DHCP Client – Addresses Only
MAC Address : Media Access Control Address used to uniquely identify the Wi-Fi interface.
IPv4 Address : The IP address that is obtained from the Wi-Fi network to which the device is currently connected.
Mask: Network mask of the Wi-Fi network to which the device is currently connected.
Gateway: Gateway IP address that is retrieved from the Wi-Fi network to which the device is currently connected.
DNS: DNS IP addresses retrieved from the cellular network or configured by user in the
Setup > Network Interfaces Configuration .
SSID: the Service Set Identifier (SSID) of the Wi-Fi Access Point to which the device is currently connected.
5.
Accessory Cards (if installed)
Card1 (AP1)
Model Number : Model number of accessory card 1.
Serial Number : Serial number of accessory card 1.
Hardware : Hardware version of accessory card 1.
Card2 (AP2)
Model Number : Model number of accessory card 2.
Serial Number : Serial number of accessory card 2.
Hardware : Hardware version of accessory card 2.
mPower TM Edge Intelligence Conduit AEP Software Guide 13
LORAWAN
Chapter 4 – LoRaWAN
LoRaWAN Network Settings
The LoRaWAN Network Settings screen contains settings for the LoRaWAN network server, Lens Server and LoRa packet forwarder. A grouping of a gateway (like your device) and end-devices (sensors) can be connected to create an application network. Through the cloud-based Lens interface, you can manage your LoRa application networks including gateway and end-devices. When the LoRa Network Server is enabled, the gateway device acts as a network server allowing end-points to join with the correct credentials on the correct frequency and sub-band.
LoRa can be configured for the 915 frequency band (AS, AU, KR, and US), or the 868 frequency band (EU, IN, and
RU). For the US, the 915 band allows 8 sub-bands. For the EU, the 868 band has three default channels and five configurable channels.
The TX (transmit power) setting is used to control the transmission power of the gateway. The Rx 1 DR Offset and
RX 2 Datarate are sent with a join response to configure the data rates used for receive windows. The offset is applied to the downlink data rate for reception on the first window according to LoRa WAN standards.
If two cards are installed, the system displays information for both cards: FPGA Version and Frequency Band using
(ap1) and (ap2) labels.
The system chooses the card to activate based on the selected channel plan.
This allows 868 and 915 cards to be installed. Only one card is be active at any time.
Use of two 915 or 868 cards is supported. Only one card is active.
After you change any of these settings, click Submit . Then, click Save and Restart to save your changes.
LoRa Mode
The LoRa Configuration pane contains the configuration values for the LoRa network server that acts as a gateway for the LoRa endpoint devices.
Item
Mode
Packet Forwarder
Packet Forwarder Status
Network Server
Network Server Status
Lens Server
Lens Server Status
Default Value
Network Server
Description
Choose from Network Server, LoRa
Packet Forwarder or Disabled.
Depends on latest software version Packet Forwarder software version
If configured properly, RUNNING Packet Forwarder status. Values include RUNNING, RESTARTED, or
DISABLED.
Depends on latest software version Network Server software version
If configured properly, RUNNING Network Server status. Values include RUNNING, RESTARTED, or
DISABLED.
Depends on latest software version Lens Server software version
If configured properly, RUNNING Lens Server status. Values include
RUNNING, RESTARTED, or DISABLED.
14 mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN
FPGA version
Restart LoRa Services button
Frequency Band (MHz)
Depends on latest software version Shows the FPGA firmware version for the installed MTAC-LORA cards.
N/A Click to restart LoRa Services. Status should change to RESTARTED then
RUNNING as a result of restart.
N/A Frequency band used which is determined by the type of MTAC-
LORA card installed. Values are 868 or 915 MHz.
LoRaWAN Network Server Configuration
The LoRaWAN Server Configuration pane contains the configuration values for the LoRa network server that acts as a gateway for the LoRa endpoint devices.
Item
Channel Plan
Channel Plan
Default Value Description
Channel Mask
US915: 915, AU915: 915, AS923:
915, KR920: 915, EU868: 868, IN865:
868, RU864: 868
N/A
LoRaWAN channel plan used for the upstream and downlink frequencies and datarates. Values are US915,
EU868, IN865, AU915, AS923,
KR920, or RU864. Available channel plans depend on the type of MTAC-
LORA card installed.
Mask of available channels. Leave empty to enable only selected subband or set as desired. Click the Edit button to select your desired channel mask(s) by checking the box under the available list of channels.
Override channel mask to include coverage provided by additional gateways. US/AU 64-channel:
00FFFFFFFFFFFFFFFFFF and
EU/AS/IN/KR: 00FF. Combine the following FSB masks to support more than 8 channels. Settings will be sent to end-devices on first downlink after OTA join: mPower TM Edge Intelligence Conduit AEP Software Guide 15
LORAWAN
Frequency Sub-Band
Frequency Sub-Band 2
Enable Diversity
Enable LBT
Max EIRP
Dwelltime Up
Dwelltime Down
Additional Channels
1
1
FSB0:
00FFFFFFFFFFFFFFFFFF
FSB1:
000100000000000000FF
FSB2:
0002000000000000FF00
FSB3:
00040000000000FF0000
...
FSB8:
0080FF00000000000000
FSB1 + FSB8:
0081FF000000000000FF
For US and AU only, 8 sub-bands are available.
For US and AU only, 8 sub-bands are available (for extra LoRa Card).
Unchecked
Unchecked
20
0 (no limit)
Enable use of two LoRa cards.
Enable Listen Before Talk. Note:
Requires FPGA v33 or v61.
Maximum uplink transmit power of end-devices (in dBm)
Maximum uplink dwell-time for region (ms). 0 : no limit and 1 : 400 ms (depends on region).
0 (no limit) Maximum downlink dwell-time for region (ms). 0 : no limit and 1 : 400 ms (depends on region).
Depends on channel plan selected A set of channels are configured based on this setting (MHz).
Frequencies supported depends on channel plan selected. v2.1
Geolocation GW - default channels must be included in the configured range. The RU864 plan uses the following channels when configured with the default settings of 0:
Radio 0: 868.9 MHz, 869.1 MHz
Radio 1: 864.1 MHz, 864.3 MHz,
864.5 MHz, 864.7 MHz, 864.9
MHz.
16 mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN
Additional Channels 2
Duty Cycle Period
Class B Settings
Enable Beaconing
Beacon Frequency
Beacon Power
Checked
0
27
Disable Ping Slot Frequency Hopping Unchecked
Ping Slot Frequency
Ping Slot Datarate
Info Descriptor
Beacon Latitude
Beacon Longitude
0: uses the Channel Plan default
Default: automatically selects the datarate for your region: US915 -
DR8, AU915 - DR8, EU868 - DR3,
IN865 - DR4, AS923 - DR3, KR920 -
DR3, RU865 - DR3
0
0
0
Enable beacon broadcasting.
Beacon frequency (MHz).
Beacon power (dBm). Select from drop-down: 0, 3, 6, 10, 11, 12, 13,
14, 16, 20, 23, 24, 25, 26, or 27.
Disable frequency hopping on beacons (only available in regions that support frequency hopping).
Frequency to use on ping slots
(MHz).
Datarate to use on ping slots Select from drop-down: DEFAULT, 8 -
SF12BW500, 9 - SF11BW500, 10 -
SF10BW500, 11 - SF9BW500, 12 -
SF8BW500, or 13 - SF7BW500.
Info Descriptor of beacon. Select from drop-down: 0, 1, or 2.
GPS latitude of antenna specified by
Info Descriptor (degrees).
GPS longitude of antenna specified by Info Descriptor (degrees).
Network
Depends on channel plan selected A set of channels are configured based on this setting (MHz).
Frequencies supported depends on channel plan selected. v2.1
Geolocation GW - Configurable for the range within the entire band.The
RU864 plan will use the following channels when configured with the default settings of 0:
Radio 0: 868.9 MHz, 869.1 MHz
60
Radio 1: 864.1 MHz, 864.3 MHz,
864.5 MHz, 864.7 MHz, 864.9
MHz.
Number of minutes in sliding windows for duty cycle restrictions
(for EU only) mPower TM Edge Intelligence Conduit AEP Software Guide 17
LORAWAN
Network Mode
18
Lease Time (dd-hh-mm)
Join Delay (Private mode)
Join Delay (Public mode)
Address Range Start
Address Range End
Rx1 Delay
NetID
Queue Size
Settings
Tx Power (dBm)
ADR Step (cB)
Antenna Gain (dBi)
Min Datarate
Rx 1 DR Offset
3
0
26
30
Public LoRaWAN
00-00-00
1 (5 if user input value is outside of range.)
5 (Also if user input value is outside of range.)
00:00:00:01
FF:FF:FF:FE
1
000000
16
Set Network Mode:
Private MTS (sync word: 0x12 and US/AU) Downlinks per
FrequencySubBand)
Public LoRaWAN (sync word:
0x34)
Private LoRaWAN (sync word:
0x12)
Amount of time until a successful join expires.
Number of seconds before receive windows are opened for join. Must match Dot settings. Range: 1-15
Number of seconds before receive windows are opened for join. Must match Dot settings. Range: 1-15
Start address to assign to OTA joining motes.
End address to assign to OTA joining motes.
Number of seconds before receive windows are opened. Must match
Dot settings. Range: 1-15
LoRaWAN NetID setting for assigning network address and beacons.
Number of downlink messages to hold per node.
0
Transmit power of the device. Value range is from 1 to 27.
Step between each datarate setting for ADR (minimum: 25).
Gain of configured antenna (-128 to
128).
Minimum datarate to use for ADR.
US: 0-4, EU/AS/RU: 0-7, AU: 0-6, KR:
0-5, IN: 1-5,7.
Offset applied to upstream data rate for downstream data rate on first receive window. US: 0-4, EU/RU: 0-5,
AS/IN: 0-7, AU: 0-7, KR: 0-5.
mPower TM Edge Intelligence Conduit AEP Software Guide
Max Datarate
Rx 2 Datarate
ACK Timeout
Database
Database Path
Reduce Uplink Writes
Backup Interval
Skip Field Check
Trim Interval
Trim Size
Fine TimeStamp
FTS Version
DSPs
DSP Stat Interval
FSK SYNC
Room Temperature
AD9361 Code
Match CRC Error mPower TM
0
12
5000 var/config/lora/lora-networkserver.db
Disabled (unchecked)
3600
Disabled (unchecked)
600
100
1
1
10
N/A
22
77
Unchecked
Edge Intelligence Conduit AEP Software Guide
LORAWAN
Maximum datarate to use for ADR.
US: 0-4, EU/AS/RU: 0-7, AU: 0-6, KR:
0-5, IN: 1-5,7.
Datarate for second receive window.
US: 0-4, EU/AS/RU: 0-7, AU: 0-6, KR:
0-5, IN: 1-5,7.
Time in milliseconds to wait for ACK before retry of confirmed downlink
Path to backup database in nonvolatile memory
Write uplink data to database every
100 packets or 5 minutes to increase uplink throughput
Interval in seconds to backup the database to flash
Skip checking JSON fields of UDP packets from packet forwarder, may increase uplink throughput
Interval in seconds to run the trim packet data tables command
Maximum size of packet tables to keep in database
The default version of the encrypted/main fine timestamp (for
FPGA >= v59). Select from dropdown: 0 or 1.
Number of DSPs (Digital Signal
Process) on the board to be booted.
DSP's reporting interval (seconds).
An hexadecimal string, 2 to 16 digits long, setting the "sync word" for FSK transmissions in TX and RX (most significant bit first).
Reference room temperature Tref used for calibration (°C)
Temperature code returned by
AD9361 radio when room temperature is Tref [0..255]
Enable/disable fine timestamp matching for packets with CRC error.
19
LORAWAN
20
GPS Receiver Checked Whether or not to use the GPS receiver in conjunction with the packet forwarder.
Network Server Logging
The logging pane specifies what format, the location and what level of server logs to save for the LoRa Server
Network.
Item
Log Destination
Path
Log Level
Default Value
Syslog blank
INFO
Click Show Advanced Settings to display the following:
Server Ports
To configure the server ports, enter the following:
Item
Local Only
Upstream Port
Default Value
Enabled (checked)
1780
Description
Select the type logging destination, either Syslog or File (use only for debug purposes to avoid filling up device RAM).
Specify the log file location.
Select the log level of the messages to be logged. Choose from dropdown: Info, Error, Warning, Debug,
Trace, and Maximum. Maximum will provide all messages.
Network Server Testing
The testing pane provides testing and debugging functions for the LoRa server.
Item
Disable Join Rx1
Disable Join Rx2
Disable Rx1
Disable Rx2
Disable Duty Cycle
Default Value
Disabled
Disabled
Disabled
Disabled
Disabled
Description
Disable sending join accept message in Rx1.
Disable sending join accept message in Rx2.
Disable sending downlink messages in Rx1.
Disable sending downlink messages in Rx2.
Disable duty cycle restrictions ( this is for testing purposes only do not use for deployments).
Description
Configure local ports only
Upstream port mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN
Downstream Port
App Port Up
App Port Down
1782
1784
1786
Payload Broker
To configure the payload broker, enter the following:
Downstream port
Application port up
Application port down
Item
Enabled
Hostname
Port
Username
Password
Default Value
Enabled (checked)
127.0.0.1
1883
N/A
N/A
Description
Enable MQTT protocol
Hostname of payload broker
Port used by MQTT
Username
Password
LoRa Packet Forwarder Configuration
The LoRaWAN Packet Forwarder pane contains the configuration values for the Packet Forwarder mode.
Item
SX1301
Frequency Band (MHz)
Default Value
N/A
Description
Frequency band used which is determined by the type of MTAC-
LORA card installed. Values are 868 or 915 MHz.
Channel Plan
Channel Plan
Enable Diversity
US915: 915, AU915: 915, AS923:
915, KR920: 915, EU868: 868, IN865:
868, RU864: 868
Unchecked
LoRaWAN channel plan used for the upstream and downlink frequencies and datarates. Values are US915,
EU868, IN865, AU915, AS923,
KR920, or RU864. Available channel plans depend on the type of MTAC-
LORA card installed.
Enable use of two LoRa cards. Both cards will be configured for the same frequencies.
mPower TM Edge Intelligence Conduit AEP Software Guide 21
LORAWAN
Additional Channels Depends on channel plan selected A set of channels are configured based on this setting (MHz).
Frequencies supported depends on channel plan selected. v2.1
Geolocation GW - default channels must be included in the configured range. The RU864 plan uses the following channels when configured with the default settings of 0:
Radio 0: 868.9 MHz, 869.1 MHz
Additional Channels 2
Frequency Sub-Band
Radio 1: 864.1 MHz, 864.3 MHz,
864.5 MHz, 864.7 MHz, 864.9
MHz
Depends on channel plan selected A set of channels are configured based on this setting (MHz).
Frequencies supported depends on channel plan selected. v2.1
Geolocation GW - Configurable for the range within the entire band.The
RU864 plan will use the following channels when configured with the default settings of 0:
Radio 0: 868.9 MHz, 869.1 MHz
1
Radio 1: 864.1 MHz, 864.3 MHz,
864.5 MHz, 864.7 MHz, 864.9
MHz.
For US and AU only, 8 sub-bands are available.
Listen-Before-Talk (LBT) - Available for AS923 and KR920 only
Enabled LBT Unchecked (disabled)
LBT RSSI Offset
LBT RSSI Target
Scan Time
Add LBT channels
Basics
-128 dB
-65 dBm
128 μ
Check s
Enable (check) LBT (Listen-Before-
Talk) when supported by hardware.
Note: Requires FPGA v33 or v61.
Adjustment value for RSSI during
LBT.
Target RSSI level for LBT, if RSSI level is above the target, then transmit is not possible.
Amount of clear time below threshold needed to allow transmission. Select from 128 or
5000 microseconds ( μ s) .
Set the LBT channels automatically.
22 mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN
Public
Gateway ID Source
Gateway ID
Gateway ID 2
Packet Forwarder Path
Beacon Configuration
Beacon Frequency
Beacon Power
Info Descriptor
Beacon Latitude
Beacon Longitude
Intervals
Keep Alive Interval
Stat Interval
Push Timeout
Autoquit Threshold
Server
Network
Unchecked (disabled)
Manual
N/A
N/A opt/lora/lora_pkt_fwd
Enable Beaconing Checked
Disabled Beacon Frequency Hopping Unchecked
0
0
0
0: uses the Channel Plan default
27
10 seconds
20 seconds
100 ms
60
Manual
Enable public mode: sync word
0×34, Disable for private mode: sync word 0×12.
Either specified in configuration
(Manual) or queried from device
(Hardware).
Installed LoRa card EUI (Extended
Unique Identifier).
Second Installed LoRa card EUI
(Extended Unique Identifier).
Path to packet forwarder binary file to execute.
Enable beacon broadcasting.
Disable frequency hopping on beacons (only available in regions that support frequency hopping.
Beacon frequency (MHz).
Beacon power (dBm). Select from drop-down: 0, 3, 6, 10, 11, 12, 13,
14, 16, 20, 23, 24, 25, 26, or 27.
Info Descriptor of beacon. Select from drop-down: 0, 1, or 2.
GPS latitude of antenna specified by
Info Descriptor (degrees).
GPS longitude of antenna specified by Info Descriptor (degrees).
Interval to send a ping to the network server.
Interval to update the network server with gateway statistics.
Timeout default.
Number of messages sent without acknowledgment from the network server
Select the network for Packet
Forwarder mode including Manual
(user determined), The Things
Network, or Semtech Demo.
mPower TM Edge Intelligence Conduit AEP Software Guide 23
LORAWAN
24
Server address
Upstream Port
Downstream Port
N/A
N/A
N/A
Server IP address to forward received uplink packets and transmit received downlink packets. The system provides the default address for The Things Network (based on your channel plan) and Semtech
Demo.
Refer to the router addresses table of The Things Network for the list of specific addresses based on channel plan: https://www.thethingsnetwork.
org/docs/gateways/packetforwarder/semtech-udp.html
If you choose The Things
Network with the AS923 channel plan, there are four different addresses available.
NOTE: No server addresses are available for The Things Network when using IN865 or RU864 channel plans.
IP Port to send received uplinks to.
The system provides default ports for The Things Network and Semtech
Demo.
IP Port to connect to network server for downlink packets. The system provides default ports for The Things
Network and Semtech Demo.
Forward CRC
Forward CRC Disabled
Forward CRC Error
Forward CRC Valid
Unchecked
Checked
Checked
Enable (check) to send packets received with CRC disabled to the network server.
Enable (check) to send packets received with CRC errors to the network server.
Enable (check) to send packets received with CRC valid to the network server.
Key Management
For Local Network Settings, after you change these fields, click Submit . Then, click Save and Restart to save your changes.
mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN
Join Server
Choose the location of your join server.
Item
Location
Default Value
Cloud Key Store
Description
Choose Remote or local Join Server to handle OTA join requests. Select from drop-down either Cloud
Key Store or Local Keys .
Add End Device Credentials
In order to use this section, you must choose Local Keys under Join Server and click on Add New to add new enddevice credentials.
Item
Dev EUI
App EUI
App Key
Class
Device Profile
Network Profile
Default Value
N/A
N/A
N/A
A
N/A
N/A
Description
Enter Device EUI.
Enter App EUI.
Enter App Key.
Select Device Class from A, B, or C.
Select Device Profile from dropdown.
Select Network Profile from dropdown.
Once you enter the above values, click Finish . Your saved end-device information displays under the Local End-
Device Credentials .
Settings ( for Cloud Key Store )
Item
Join Server URL
Enable Lens API
Lens API URL
Check-In Interval
Gateway EUI
UUID
Serial Number
Default Value https://join.devicehq.com/api/m1/join req
Disabled (Unchecked) https://lens.devicehq.com/api/
3600
Description
Join Server address (You can verify the join server by clicking the Test button.)
Enable Lens API to use Lens portal to manage
LoRaWAN network.
Lens API URL.
N/A
N/A
N/A
Number of seconds between device check-in to
Lens cloud.
Gateway EUI (Extended Unique Identifier)
Universally Unique Identifier (128-bit ID)
Device serial number mPower TM Edge Intelligence Conduit AEP Software Guide 25
LORAWAN
26
Messages (available using Cloud Key Store)
Item
Network Stats
Default Value
Enabled
Packet Metadata
Packet data
Gateway Stats
Local Join Metadata
DeviceHQ
Enabled
Disabled
Enabled
Enabled
Enabled
Description
Send periodic network stats to Lens servers.
Send metadata on uplink and downlink packets to Lens servers.
Send data from uplink and downlink packets to Lens servers.
Send periodic gateway stats to Lens servers.
Send periodic gateway stats to Lens servers.
Allows Lens to control DeviceHQ connectivity settings (optional).
Gateway Info (available using Cloud Key Store)
Item
Gateway EUI
UUID
Serial Number
Default Value
N/A
N/A
N/A
Traffic Manager (available using Cloud Key Store)
Item
JoinEUI Filter
Default Value
N/A
DevEUI Filter N/A
Description
Applied to received Join Requests to limit the number of messages sent to Join Server from unwanted devices (Readonly display of logic downloaded from Lens settings).
Applied to received Join Requests to limit the number of messages sent to the Join Server from unwanted devices
(Read-only display of logic downloaded from Lens settings).
Local Network Settings
Item
Enabled
Default Value
Checked (enabled)
Description
Gateway EUI (Extended Unique Identifier)
Universally Unique Identifier (128-bit ID)
Device serial number
Description
Enable or disable Local Network
Settings.
mPower TM Edge Intelligence Conduit AEP Software Guide
Network ID (AppEUI)
Name
Default Profile
Network Key (AppKey)
Passphrase
Key
Spectral Scan Configuration
Item
Enabled
Scan Settings
Samples
Bandwidth
Step
Offset
Floor
Scheduling
Start
Interval
Stop
Duration
Name
Uses local device name.
DEFAULT-CLASS-A
Passphrase
N/A
N/A
9:00
1
Never
1
Default Value
Unchecked (disabled)
10000
250
100000
0
-120 mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN
Specify Network ID format from local application network ID or App EUI.
Select from drop-down: Name or
EUI.
Gateway device name.
Default network profile to use for newly joined end-devices. Choose from Class A, B, or C.
Choose Network Key from
Passphrase or Key.
Enter Passphrase if used.
Enter Key if used. (128-bit hexadecimal value)
Description
Enable or disable Spectral Scan.
Total number of RSSI points.
Channel bandwidth (in KHz).
Frequency step between start and stop (in Hz).
Offset to be applied to resultant data (in db).
Threshold below which results are ignored (in db).
Start time for scans in UTC time
(leave blank if you want current time).
Time period between run sets
(minutes).
Stop criteria for scans. Select from drop-down: Never, After Duration, and After Number of Scans
Time period to run continuous scans
(in hours). Use 0 for once. (Shows up if you choose After Duration under
Stop.)
27
LORAWAN
28
Start 3
Stop 3
Start 4
Stop 4
Start 5
Stop 5
Scan Sets to Run 0 Scan limit (Shows up if you choose
After Number of Scans under Stop.)
Scan Sets - First set range is required and two default ranges are provided. Others are optional up to 5 max. Each range set is independent and flexible. Enter start and stop range and click Add to add that range as an additional set. Click Remove to delete one.
Start 1
Stop 1
Start 2
Stop 2
902100000
903900000
923000000
928000000
Start frequency 1 (in Hz) - Required.
Stop frequency 1 (in Hz) - Required.
Start frequency 2 (in Hz) - Optional.
Stop frequency 2 (in Hz) - Optional.
N/A
N/A
N/A
N/A
N/A
N/A
Start frequency 3 (in Hz) - Optional.
Stop frequency 3 (in Hz) - Optional.
Start frequency 4 (in Hz) - Optional.
Stop frequency 4 (in Hz) - Optional.
Start frequency 5 (in Hz) - Optional.
Stop frequency 5 (in Hz) - Optional.
Gateways
This section displays all active and configured gateways. The following information displays:
Item
Gateway EUI
IP address
IP Port
Version
Last Seen
Options
Description
Gateway EUI (Extended Unique Identifier)
Gateway IP address
Port used for LoRaWAN Gateway
Protocol version of Packet Forwarder
Time of last update, Minutes or hours ago
Additional statistics and details for Gateway option in last five minutes. Click info icon for details.
Packets Received
Item
Gateway EUI
Channels 1 -10
CRC
Adding Total
Network Statistics
Item
Description
Gateway EUI (Extended Unique Identifier)
Number of packets received on this channel
Cyclic Redundancy Check failed
Count of packets on all channels including CRC errors
Description mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN
Join Request Responses
Join Packets
Transmitted Packets
Received Packets
Scheduled Packets
Average Join Request Response in milliseconds: 90%,
70%, 30%
Number of Okay packets, Duplicates and MIC fails,
Unknown, Late, Total
Pkt (Packets) 1st Wnd (Window), Pkt 2nd Wnd, ACK Pkt,
Total, Join 1st Wnd, Join 2nd Wnd, Join Dropped, Join
Total
MIC Fails, Duplicates, CRC Errors, Total
1st Wnd, 2nd Wnd, Dropped, Total
Duty Cycle Time-On-Air Available (seconds - only available for EU)
Item
Gateway EUI
Bands 0-3
Description
Gateway EUI (Extended Unique Identifier)
Channel bands
Devices
This section allows users to add new end-devices. To add a new end-device:
1.
Go to LoRaWAN > Devices .
2.
Under End Devices , click Add New .
3.
Enter the following fields: a.
Dev EUI - the end-device EUI (Extended Unique Identifier) b.
Name - the name of the end-device c.
Class - LoRaWAN operating class of end-device. Is communicated to network server on Join. The end-device must be configured out-of-band for operating class. A, B, or C are currently supported.
(A, B, or C).
d.
Serial Number - Serial number of end-device e.
Product ID - Product ID for end-device f.
Hardware Version - Hardware version for the end-device g.
Firmware Version - Firmware version for the end-device h.
LoRaWAN Version - Software version for LoRaWAN server
4.
Click Finish .
5.
The new end-device displays under the End Devices list including some device details and statistics.
6.
To edit the device, click the pencil icon, or to delete it, click the x icon next to that device.
Device Sessions
The normal join process involving properly configured and registered gateways and end-devices creates sessions
FOTA (Firmware Over-the-Air) automatically.
mPower TM Edge Intelligence Conduit AEP Software Guide 29
LORAWAN
However, you can use the Device Sessions section, if you want to create a session manually, otherwise known as
ABP (Activation by Personalization). The manual session includes only the gateway and end-devices. The server is not involved.
To add a new session manually:
1.
Go to LoRaWAN > Devices .
2.
Under Sessions , click Add New .
3.
Enter the following fields: a.
Dev EUI - End-device EUI (Extended Unique Identifier) b.
Dev Addr - Network device address assigned to end-device c.
App EUI - Application EUI d.
Join EUI - Join Request EUI e.
Net ID - Network ID f.
App Session Key - Pre-shared application session key g.
Net Session Key - Derived network session key based on pre-shared application key
4.
Click Finish .
5.
The new session displays under the Sessions list including some device details and statistics.
a.
Dev EUI - End-device EUI (Extended Unique Identifier) b.
Dev Addr - Network device address assigned to end-device c.
Up FCnt - Packet counter of last received packet d.
Down FCnt - Packet counter of last sent packet e.
Last Seen - Time of last packet received f.
Joined - What is the device joined to, Cloud or local version g.
Details - Additional session information (click on info icon)
6.
To edit the session, click the pencil icon, or to delete it, click the x icon next to that session.
Device Groups
This page allows you to create Device Groups in order to perform mass firmware upgrade OTA and multicast messaging to all devices in that group.
The Groups table displays existing groups. Use the View , Edit, or Remove buttons to see, modify, or delete an existing group in the table.
To create a new device group:
1.
Go to LoRaWAN > Device Groups .
2.
Click the Add New button.
3.
The Add Group dialog box appears. Enter your desired Group Name .
4.
You can also enter an optional Group EUI . If you do not provide one, the system generates a Group EUI automatically.
5.
Select the desired end device(s) to include in your group by clicking the box next to each Device EUI .
6.
Click Add .
30 mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN
To import your device group:
1.
Click Import .
2.
Click Choose File and browse to select your desired file.
3.
Click Import .
To export all your device groups, click Export All .
Groups table fields
Item
Name
EUI
Size
Options
Description
Device Group Name (user-defined)
Optional Device Group EUI (the system generates one for you if undefined)
Number of devices in the group
Edit and Delete options
Profiles
When connected to the LoRaWAN server, the profiles can be downloaded from the cloud. There are two-kinds of profiles: End-Device and Network.
Make profile changes in the Lens cloud and the device updates during a periodic check-in or when end-device associated with the profile joins or rejoins the network.
See existing profiles under the End-Device Profiles and Network Profiles lists. Refer to tables for profile details.
Click Refresh to update the list.
Settings provided in the device profile must reflect the default settings of the end-device when it is first joined to the network. The end-device should be in this default configuration. Any deviation between the device profile and the actual default end-device settings may result in lost downlinks to the end-device due to non-matching Rx window parameters.
To add a new device profile:
1.
Go to LoRaWAN > Profiles .
2.
Under End-Devices Profiles , click Add New .
3.
Enter the fields or check the following boxes: a.
Profile ID - Enter your desired profile name.
b.
Max EIRP c.
Max Duty Cycle - Select from the drop-down including DEFAULT or a range of options from 100% to
0.003%.
d.
MAC Version.
e.
RF Region - Select from the drop-down including DEFAULT, US915, AU915, AS923, KR920, EU868,
IN865, and RU864.
f.
Region Version.
g.
Supports Class C (Check box to enable. If this is enabled, then you may enter a value for the following field.) mPower TM Edge Intelligence Conduit AEP Software Guide 31
LORAWAN
32 i.
Timeout Class C h.
Supports Class B (Check box to enable. If this is enabled, the following fields appear and you may enter values for them.) i.
Ping Slot Period ii.
Ping Slot Datarate iii.
Ping Slot Frequency i.
Supports Join (check box to enable) j.
Support 32 Bit FCnt (check box to enable)
End-Device Profiles (edit/add new)
Parameter
Profile ID
Max EIRP
Max Duty Cycle
MAC Version
RF Region
Region Version
Supports C
Timeout C
Supports B
Timeout B
Ping Slot Period
Ping Slot Datarate
Ping Slot Frequency
Supports Join
Rx1 Delay
Rx1 DR Offset
Rx2 DR Index
Description name of profile maximum transmit power of the end-device maximum duty-cycle of the end-device
LoRaWAN version supported by end-device, LW1_0 has different MAC commands, and network messages from
LW1_1 end-device region or channel plan revision of Regional Parameters specification true if end-device can use class C mode time for the end-device to reply to a confirmed downlink before retransmission true if end-device can use class B mode time for the end-device to reply to a confirmed downlink before retransmission how often the end-device opens class B windows – 1
(once per second) up to 128 (once per beacon period) datarate used for class B window frequency used for class B window true if end-device supports OTA join default delay between end of Tx and beginning of the first Rx window, if not provided the LoRaWAN default for the selected channel plan will be used.
default datarate offset of first Rx window, if not provided the LoRaWAN default for the selected channel plan will be used default datarate of second Rx window, if not provided the LoRaWAN default for the selected channel plan will be used mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN
Rx2 Frequency
Preset Frequencies
Supports 32 Bit FCnt default frequency of second Rx window, if not provided the LoRaWAN default for the selected channel plan will be used additional channels configured at the end-device true if end-device supports 32 bit counters
Network Profiles
Settings provided in the network profile reflect the settings of the end-device to be received in MAC commands after it is first joined to the network. These are the desired settings for the end-device to operate with. Any deviation between the network profile and the default end-device settings are sent to the end-device in successive
MAC commands until all settings have been relayed.
NOTE: Network profile settings will override device profile and network settings.
To add a new network profile:
1.
Go to LoRaWAN > Profiles .
2.
Under Network Profiles , click Add New .
3.
Enter the fields or check the following boxes: a.
Profile ID – Enter your desired profile name.
b.
Max Duty Cycle - Select from the drop-down including DEFAULT or a range of options from 100% to
0.003% c.
Class- Select from the drop-down including A, B, or C.
d.
Timeout Class C e.
Rx1 Delay f.
Rx1 DR Offset - Select from drop-down which varies with your selected channel plan.
g.
Rx2 DR Index - Select from drop-down which varies with your selected channel plan.
h.
Rx2 Frequency i.
Channel Mask j.
Redundacy
Network Profiles (edit/add new)
Parameter
Profile ID
Max Duty Cycle
Class
Timeout C
Rx1 Delay
Description name of profile maximum duty-cycle of the end-device operating class for end-device: A, B or C time for the end-device to reply to a confirmed downlink before retransmission default delay between end of Tx and beginning of the first Rx window, if not provided the LoRaWAN default for the selected channel plan will be used mPower TM Edge Intelligence Conduit AEP Software Guide 33
LORAWAN
Rx1 DR Offset
Rx2 DR Index
Rx2 Frequency
Channel Mask
US
EU
Redundancy default datarate offset of first Rx window, if not provided the LoRaWAN default for the selected channel plan will be used default datarate of second Rx window, if not provided the LoRaWAN default for the selected channel plan will be used default frequency of second Rx window, if not provided the LoRaWAN default for the selected channel plan will be used bitmask of enabled channels, US/AU use a twenty character mask, other use a four character mask first 2 characters are not used, the next two control the
500 KHz channels: enable all channels – 00FFFFFFFFFFFFFFFFFF enable bottom half - 000F00000000FFFFFFFF enable all channels - FFFF number of times an unconfirmed uplink should be repeated
Packets
This section shows three lists: transmitted, recent join requests, and recently received packets on the LoRa network. Each packet includes relevant packet details.
Packets (Transmitted)
Item
Device EUI
Freq
Datarate
SNR
CRC
RSSI
Size
FCnt
Description
End-device EUI (Extended Unique Identifier) transmitting the uplink packet or destination of the downlink packet
Frequency used to transmit packet
Datarate used to transmit packet
Signal to noise ratio of received packet
Cyclic redundancy check failed
Received signal strength
Size in bytes of packet
MAC packet counter
34 mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN
Type Type of packet includes these possible values:
JnAcc - Join Accept Packet
JnReq - Join Request Packet
UpUnc - Uplink Unconfirmed Packet
UpCnf - Uplink Confirmed Packet - ACK response from network requested
DnUnc - Downlink Unconfirmed Packet
DnCnf - Downlink Confirmed Packet- ACK response from end-device requested
Time packet was sent or received
Additional packet details (click on info icon to view popoup)
Tx/Rx Time
Details
Recent Join Requests
Item
Join EUI
Nonce
Elapsed
Result
Description
8-byte EUI (Extended Unique Identifier) found in the join request
Join nonce provided by end-device in the Join Request
Round trip time in milliseconds for the Join Server to service the join request
If the result of the request is valid, it displays: Success .
If the result is an error, one of the following displays:
MICFailed - AppKey setting did not match the end-device record in Join Server
Dropped - Downlink packet could not be scheduled for transmit on any available gateways
Duplicate Dev Nonce - Nonce in join request has already been used
JoinReq Failed - Other server error
UnknownDevEUI - Device record was not found at Join Server
Gateway Mismatch - Join Server configuration does not allow this device to join through this gateway
Server Error - Join Server is not reachable possibly due to Internet connection settings or DNS resolution
Recent Rx Packets
Item
Time mPower TM Edge Intelligence Conduit AEP Software Guide
Description
Time packet was received
35
LORAWAN
36
Freq
Datarate
CRC
SNR
RSSI
Size
Type
Data
Details
Frequency used to transmit packet
Datarate used to transmit packet
Cyclic redundancy check failed
Signal to noise ratio of received packet
Received signal strength
Size in bytes of packet
Type of packet includes these possible values:
JnAcc - Join Accept Packet
JnReq - Join Request Packet
UpUnc - Uplink Unconfirmed Packet
UpCnf - Uplink Confirmed Packet - ACK response from network requested
DnUnc - Downlink Unconfirmed Packet
DnCnf - Downlink Confirmed Packet- ACK response from end-device requested
Actual data in packet (payload)
Additional packet details (click on info icon to view popup)
Downlink Queue
You can manually send a downlink packet to an end-device.
The packet remains in the queue until sent. Once it has been transmitted/received, the packet displays under
Packets .
To manually send a downlink packet:
1.
Go to LoRaWAN > Downlink Queue . Click on Add New .
2.
Enter the following fields for the new Queue Item: a.
Dev EUI - receiving end-device EUI (Extended Unique Identifier) b.
App Port - port field set in the downlink packet c.
Data Format - encoding scheme for the packet (select either Hex or Base64).
d.
Data - the payload (data being transmitted) e.
Ack Attempts - number of allowed downlink request ack retries f.
RxWindow - specify the Rx Window to use for downlink (0 - no priority, 1- first Rx Window, 2second Rx Window)
3.
Click Finish .
4.
The new Queue Item displays under the Downlink Queue list including some device details and statistics.
a.
Dev EUI - receiving end-device EUI (Extended Unique Identifier) b.
App Port - port field set in the downlink packet c.
Size - total packet minus header mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN d.
Ack - number of retries to receive ACK from end-device e.
RxWnd - the Rx Window to use for downlink (0 - no priority, 1- first Rx Window, 2- second Rx
Window) f.
Queued - Time packet has been added to the queue g.
Details - additional statistics displayed related to the packet
5.
To edit the item, click the pencil icon, or to delete it, click the x icon next to that item.
Operations
The LoRaWAN Operations page offers two different features on one page: FOTA or Multicast Messaging .
The device offers the option of FOTA using your LoRaWAN network. To use this feature, you must properly configure your LoRa network and end-devices (must be joined to the network). You may set a countdown for an immediate update or schedule the upgrade for a specific time. You can also update multiple devices on your LoRa network.
The device also offers the option of Multicast Messaging over the LoRaWAN network.
To perform FOTA :
1.
Go to LoRaWAN > Operations .
2.
Under Operations Settings , select FOTA in the Operation Type drop-down.
3.
Click Browse and select your Firmware Upgrade File (.bin).
4.
Under the Fragment Description field, enter the fragment description for the FOTA session in HEX format.
5.
You have the option to specify a Setup Time In by clicking Change . Setup time specifies how long from the time scheduled before the Multicast Setup Process begins. Under Setup Time Input from the dropdown, select either: a.
Countdown to Setup from Now: Enter Number of Days plus hours, minutes and seconds in
HH:MM:SS (default: 30 seconds) OR b.
Specify Future Date and Time: Select your desired Date and Time .
6.
Otherwise, click Hide to hide Setup Time Input details. Click Change to show and modify.
7.
You have the option to specify a Launch Time In . Launch time specifies how long the Multicast Process runs before starting firmware transmission. Under Launch Time Input from drop-down, select either: a.
Countdown to Launch from Setup: Enter Number of Days plus hours, minutes and seconds in
HH:MM:SS (default: 90 seconds) OR b.
Specify Future Date and Time: Select your desired Date and Time .
8.
Choose the desired Target End-Devices to receive the upgrade. Select either a previously-saved End-
Device Group or Individual Devices from the drop-down on the right. Check the box near your desired device or group to designate it for upgrade. You can also check Select/Deselect All box to select or deselect all groups in the list.
9.
Click the Settings tab, if you wish to change the defaults for the following FOTA parameters a.
Delete Successful Logs (default: checked) b.
Number of Parity Fragments per Session (default: 100) c.
Sleep Delay between Setup Messages (default: 1000 microseconds) d.
Sleep Delay between Data Fragments (default: 1500 microseconds) mPower TM Edge Intelligence Conduit AEP Software Guide 37
LORAWAN e.
Sleep Delay between Parity Fragments (default: 3000 microseconds)
10.
After configuring FOTA, click Schedule to finalize your FOTA update.
11.
Once the scheduled upgrade is submitted, you can track its progress through the Progress tab. A progress bar appears at the top of the page. The progress bar shows the transfer of the file from the PC to the device. Once completed, the page switches to the Progress tab. The job displays in either Scheduled,
Active , or Completed Jobs lists depending on the job phase and timing.
To perform the Multicast Messaging :
1.
Go to LoRaWAN > Operations .
2.
Under Operations Settings , select Message in the Operation Type drop-down.
3.
Select from either Textbox or File under Payload Source .
4.
Select from either Hexadecimal or Base64 under Payload Format .
5.
Enter the message contents under Payload .
6.
Enter the Port from a range of 1-220 (default: 1).
7.
Under Transmission Setup , you have the option to specify a Setup Time In by clicking Change . Setup time specifies how long from the time scheduled before the Multicast Setup Process begins. Under Setup Time
Input from the drop-down, select either: a.
Countdown to Setup from Now: Enter Number of Days plus hours, minutes and seconds in
HH:MM:SS (default: 30 seconds) OR b.
Specify Future Date and Time: Select your desired Date and Time .
8.
Otherwise, click Hide to hide Setup Time Input details. Click Change to show and modify.
9.
You have the option to specify a Launch Time In . Launch time specifies how long the Multicast Process runs before starting message transmission. Under Launch Time Input from drop-down, select either: a.
Countdown to Launch from Setup: Enter Number of Days plus hours, minutes and seconds in
HH:MM:SS (default: 90 seconds) OR b.
Specify Future Date and Time: Select your desired Date and Time .
10.
Choose the desired Target End-Devices to receive the message. Select either a previously-saved End-
Device Group or Individual Devices from the drop-down on the right. Check the box near your desired device or group to designate it to receive the message. You can also check Select/Deselect All box to select or deselect all groups in the list.
11.
Click the Settings tab, if you wish to change the defaults for the following message parameters a.
Delete Successful Logs (default: checked) b.
Sleep Delay between Setup Messages (default: 1000 microseconds) c.
Sleep Delay between Data Fragments (default: 1500 microseconds)
These parameters are constants for multicast messaging and cannot be modified: a.
Number of Parity Fragments per Session (value: 100) b.
Sleep Delay between Parity Fragments (value: 3000 microseconds)
12.
After configuring Mulitcast Messaging , click Schedule to schedule your message .
13.
Once the message is submitted, you can track its progress through the Progress tab. A progress bar appears at the top of the page. The progress bar shows the transfer of the message from the PC to the
38 mPower TM Edge Intelligence Conduit AEP Software Guide
LORAWAN device. Once completed, the page switches to the Progress tab. The job displays in either Scheduled,
Active , or Completed Jobs lists depending on the job phase and timing.
mPower TM Edge Intelligence Conduit AEP Software Guide 39
SETUP
Chapter 5 – Setup
Network Interfaces
For configuration management of network interfaces, go to Setup > Network Interfaces > Network Interfaces
Configuration . This section displays the list of network interfaces. Click on the pencil icon to the right of a particular interface in order to edit its configuration. Refer to possible configurations in the table below.
Bridge
This section allows you to create a bridge between network interfaces. All LAN network interfaces are added into the bridge (br0) by default.
Just LAN interfaces are allowed under bridge including Ethernet (eth0, eth1, eth2) and wlan1 (Wi-Fi Access Point).
With this bridge interface added, it is possible to assign any number of LAN interfaces (of both Ethernet and Wi-Fi
AP types) to a specified bridge. Only one bridge interface is supported.
IPv6 support is also available under the bridge using Static IP mode.
Slave Interfaces
Slave interfaces such as Ethernet (eth0, eth1, eth2) or Wi-Fi AP ( wlan1 ) do not have their own IP addresses and are not configured as DHCP clients by default. Static IP address mode is implemented on the bridge level.
Ethernet Interface
The Ethernet interface can be configured as either LAN or WAN . Ethernet interface as LAN can be set to use static pre-set IPv4 or IPv6 addresses or dynamically obtain an IPv4/IPv6 address over DHCP in DHCP client mode. When configured as WAN , only IPv4 is available.
PPP interface
The PPP interface is only allowed to be WAN . The PPP interface listed in the Network Interfaces page can only have its mode changed. Options are PPP and PPP addresses-only modes. IPv6 WAN support is also an option with the PPP interface (configurable fields vary with network carrier).
Wi-Fi integration
Wi-Fi integration is enabled by adding two network interfaces: wlan0 (used exclusively for Wi-Fi as WAN
(STATION) mode) and wlan1 (used exclusively for AP mode). The Web UI as well as API back-end has been modified to add support and validation rules in order to assign LAN interface(s) to a bridge, and removing them from under the bridge.
NOTE: Wi-Fi availability depends on model. Consult the appropriate manual for details.
40
Network configurations
Refer to the following table for the possible network configurations:
Interface Direction Type IP Mode
Br0 N/A
Eth0, Eth1, Eth2 LAN
BRIDGE
Ethernet
STATIC
STATIC
Bridge Mode
Br0
N/A
IPv4/IPv6
Support
Both
Both mPower TM Edge Intelligence Conduit AEP Software Guide
SETUP
Eth0, Eth1, Eth2 LAN
Eth0, Eth1, Eth2 LAN
Eth0, Eth1, Eth2 WAN
Eth0, Eth1, Eth2 WAN
Eth0, Eth1, Eth2 WAN
Wlan0
Wlan0
Wlan1
Wlan1 ppp0 ppp0
WAN
WAN
LAN
LAN
WAN
WAN
Ethernet
Ethernet
Ethernet
Ethernet
Ethernet
Wi-Fi as WAN
Wi-Fi as WAN
Wi-Fi AP
Wi-Fi AP
Cellular
Cellular
DHCP Client
N/A
STATIC
DHCP Client
DHCP Client -
Addresses Only
N/A
Br0
N/A
N/A
N/A
DHCP Client
DHCP Client -
Addresses Only
STATIC
N/A
PPP
PPP - Addresses
Only
N/A
N/A
N/A
Br0
N/A
N/A
Both
N/A
IPv4 only
IPv4 only
IPv4 only
IPv4 only
IPv4 only
IPv4 only
IPv4 only
Both
Both
IPv6 Example Configurations
Configuration Example #1: Cellular WAN, Delegated LAN
This example is the most typical configuration. The admin user enables IPv6 on the Cellular Configuration, configures the bridge interface on the device in Delegated Prefix mode and, configures all LAN interfaces that will perform IPv6 as slaves of the bridge interface. The LAN networks “under” the bridge will all have the whole 64 bit prefix delegated to them. The bridge and Cellular WAN interfaces will have the same IPv6 address. In this manner, the router will act as the gateway to the Internet for all the LAN devices that have delegated addresses.
WAN interface is configured in Automatic Client IPv6 Mode.
All LAN interfaces are connected to the bridge interface.
The bridge interface is configured in the Delegated Prefix mode.
The whole /64 prefix is delegated to the LAN network.
The Bridge interface and Cellular WAN interface have the same IPv6 address.
mPower TM Edge Intelligence Conduit AEP Software Guide 41
SETUP
Configuration Example #2: No IPv6 WAN, Static LAN
This example is essentially the same as the old mode where IPv6 was not supported. The devices have Internet access via IPv4, but not via IPv6. On the LAN side, the admin user assigns a static IPv6 address to the br0 (bridge) interface and all the IPv6 addresses on the LAN side will be assigned by the user. In this case, the device may be managed through the LAN interface over IPv6.
IPv6 support disabled on WAN interface or IPv6 is not supported on cellular provider.
Devices in LAN1 will see each other.
Devices in LAN1 will not have Internet access over IPv6.
42
Configuration Example #3: Cellular WAN, Static LAN with valid addresses
This example is typically the second most widely used IPv6 scenario since not all ISPs support prefix delegation automatically. In this case, the cellular provider or ISP provides the admin user with global address of the device is and the IPv6 prefix that needs to be assigned to the LAN devices. The LAN devices are all programmed with a valid
IPv6 address statically by the admin user with the knowledge of what IPv6 prefix to use provided by the Cellular
Provider / ISP. All the LAN devices can access the Internet via IPv6 if they have a global IPv6 address configured.
mPower TM Edge Intelligence Conduit AEP Software Guide
It is known exactly what IPv6 subnet is assigned to the device by the cellular provider/ISP.
All devices in LAN1 will have IPv6 Internet access.
SETUP
Configuration Example #4: Cellular WAN, Static LAN with user-selected addresses
For this example, the LAN has IPv6 addresses, but they're not in the recognized range of addresses the cellular provider/ISP have specified with a prefix. The LAN devices will network with each other over IPv6, but do not have
Internet access via IPv6. The device can ping IPv6 addresses on the Cellular WAN. However, since the LAN devices don’t have globally routable addresses recognized by the cellular provider/ISP, they get their packets dropped on the WAN link.
LAN subnet is outside of the range of addresses provided by the cellular provider/ISP.
Devices in LAN can see each other via IPv6.
Devices in LAN do not have Internet access via IPv6.
The router can ping IPv6 addresses.
All packets with invalid IPv6 addresses are dropped on the WAN link.
mPower TM Edge Intelligence Conduit AEP Software Guide 43
SETUP
Configuration Example #5: Cellular WAN, Static LAN, Delegated Prefix LAN
This scenario is a combination of examples #1 and #3. The difference is the Static LAN2 does not have Internet access because the prefix for the statically assigned addresses on that LAN do not match the delegated prefix from the cellular provider/ISP. The devices on LAN1 got their IPv6 addresses from the router that is using the delegated prefix from the cellular provider/ISP, so those devices have Internet access via IPv6. This example demonstrates the difference in behavior for the LAN networks based on the prefix delegation.
User configured LAN1 in Delegated Prefix IPv6 mode.
User configured LAN2 in Static IPv6 mode with user-selected addresses
Devices in LAN2 will see each other.
Devices in LAN1 will have Internet access via IPv6.
Devices in LAN2 will not have Internet access via IPv6.
44
Configuration Example #6: No IPv6 WAN, Static LAN
For this example, IPv6 is enabled on the LAN interface but disabled on the WAN side or not supported by the cellular provider/ISP. The delegation fails. This results in LAN1 not receiving delegated IPv6 addresses as it should, but only link-local IPv6 addresses. LAN2 has statically defined IPv6 addresses, but does not have Internet access since the device does not have an established IPv6 connection.
IPv6 support disabled on WAN interface or IPv6 is not supported by cellular provider/ISP.
Delegation fails.
Devices in LAN1 will not get any IPv6 addresses (except link-local).
Devices in LAN2 will see each other and have IPv6 addresses.
No IPv6 Internet access.
mPower TM Edge Intelligence Conduit AEP Software Guide
SETUP
Global DNS
The Global DNS Configuration page allows the user to set user-defined DNS servers. User-defined DNS servers in this page are always used to resolve hostnames regardless of what the WAN settings are and what WAN interface is being used. If the Global DNS primary and secondary servers are not configured here, the DNS servers used default to the servers configured for the current WAN.
Here are the key configuration scenarios for both Global DNS and forwarding server and their results (the device refers to a MultiTech device):
If you do not configure Global DNS and enable forwarding, the device acts as a proxy server for any devices on the LAN network(s). In this mode, the device uses WAN DNS settings. Client settings: On the client, you must configure the device as the default gateway and DNS server. The easiest way to accomplish this is by using the DHCP server on the device.
If you configure Global DNS and enable forwarding, DNS requests are forwarded to servers configured in the Global DNS settings. The device still acts as a proxy. Client settings: Clients must be configured the same as in the previous case above.
If you configure Global DNS and disable forwarding, the default gateway and DHCP server on clients should point to the device and the DNS servers on the client must use the same DNS as the Global DNS settings.
Client settings: The client device uses the device as default gateway and the DHCP server, but must have
DNS servers configured to what options you plan to use.
If neither item is configured/enabled, make sure to configure your device properly to forward DNS.
To configure Global DNS :
1.
Click Setup > Global DNS.
2.
Under Global DNS Configuration , leave Enable Forwarding Server unchecked. (If you check this, the forwarding server is active and global DNS is not configured).
3.
To set global DNS servers, enter IP addresses for the both Primary and Secondary Servers . (These servers override any DNS servers specified elsewhere in the UI. If none are entered, the system defaults to servers configured for the current WAN.)
4.
Under Hostname Configuration , enter the Hostname for your device.
5.
Click Submit .
mPower TM Edge Intelligence Conduit AEP Software Guide 45
SETUP
46
6.
Click Save and Restart to save your changes.
WAN Setup
Configuring WAN Failover Priority
Failover mode regulates which WAN is used for the Internet connection and switches the WAN if a connectivity failure is detected.
Failover mode enables the WAN with the highest priority as displayed on the WAN Configuration page. If the WAN with priority 1 is disabled or a connection failure is detected, the WAN with priority 2 is automatically selected for establishing connection to the Internet.
Ethernet (eth0) is priority 1 by default.
If Ethernet is used as WAN, the DHCP server must be disabled.
1.
Click Setup > WAN Configuration .
2.
Under Options , click the up and down arrows to change the priority of the appropriate WAN.
3.
Click Save and Restart to save the change.
For field descriptions see
For information on editing WAN Failover see
Editing Failover Configuration
Editing Failover Configuration
The device can use the active or passive mode to monitor the Internet availability in WAN. The default condition is active mode.
Active mode can be type ICMP (ping) or TCP. ICMP periodically pings the designated host at the specified interval.
TCP tries to make a connection to the designated host at the interval specified.
For both ICMP and TCP, if a response is not received, the device switches to the WAN with lower priority. The device continues to ping the designated host at the interval specified for WAN with the higher priority and switches back when the ping is successful. When passive mode is enabled, the device switches the WANs when the network interface is down. The currently active WAN is displayed on the home page under the label WAN
Transport.
To edit failover configuration:
1.
Click Setup > WAN Configuration .
2.
Under the Options column at the right, click the pencil icon (edit) for the selected WAN. The Failover
Configuration page is displayed.
3.
Make the desired changes. Refer to
for details.
4.
Click Finish .
5.
If you are finished making changes, click Save and Restart .
Failover Configuration Fields
Field
Monitoring Mode
Description
Use the drop-down list to select the mode to connect to the host: PASSIVE or
ACTIVE.
mPower TM Edge Intelligence Conduit AEP Software Guide
SETUP
Field
Interval
Host Name
Mode Type
TCP Port
ICMP Port
Description
Enter the number of seconds between each check. Default is 60 seconds.
Enter the host name or IP address to use for the check. Default is www.google.com.
Use the drop-down list to select the mode type: ICMP or TCP. Default is ICMP.
(Active Monitoring Mode)
Enter the TCP Port number to connect to the host. (Mode TCP)
Enter the number of ICMP pings to be sent to the specified host. Default is 10.
(Mode ICMP)
Configuring IP Address for LAN
Your device manages traffic for your local area network (LAN). To change the IP address and DNS configuration:
1.
Go to Setup > Network Interfaces > br0 and click the pencil icon to edit.
2.
To configure the address LAN information:
In the IP Address field, type the device's IP address. The default is 192.168.2.1.
In the Mask field, type the mask for the network. The default is 255.255.255.0.
3.
To resolve domain names, configure domain name server information (DNS), go to Setup > Global DNS and refer to the Global DNS section (WAN DNS) for options and instructions on how to properly configure this feature.
4.
Click Submit .
5.
To save your changes, click Save and Restart .
Configuring Dynamic Domain Naming System (DDNS)
This feature allows your router to use a DDNS service to associate a hosted server's domain name with a dynamically changing internet address. To configure your router to use DDNS:
1.
From Setup , select DDNS Configuration .
2.
In the Configuration group, check Enabled .
3.
In the Service drop-down list, select a DDNS service. To define a service that isn't listed choose Custom .
a.
For custom DDNS service, in the Service field, type the DDNS server's URL.
b.
For custom DDNS service, in the Port field, type the DDNS server's port.
4.
In the Domain field, type the registered Domain name.
5.
In the Update Interval field, type the days that can pass with no IP Address change. At the end of this interval, the existing IP Address is updated on the server so that the address does not expire. The range of the interval you can enter is between 1 and 99 days. The default is 28 days.
6.
Check Use Check IP , if you want to query the server to determine the IP address before the DDNS update.
The IP address is still assigned by the wireless provider and the DDNS is updated based on the address returned by Check IP Server. If disabled, the DDNS update uses the IP address from the PPP link. The default is Use Check IP .
7.
In the Check IP Server field, type the name to which the IP Address change is registered. Example: checkip.dyndns.org
8.
In the Check IP Port field, type the port number of the Check IP Server. The default is 80.
mPower TM Edge Intelligence Conduit AEP Software Guide 47
SETUP
9.
Click Submit .
10.
To save your changes, click Save and Restart .
Entering authentication information
Your DDNS server requires you to identify yourself before you can make changes.
1.
In the Username field, type the name that can access the DDNS Server. The default is NULL. You receive your name when you register with the DDNS service.
2.
In the Password field, type the password that can access the DDNS Server. The default is NULL. You receive your password when you register with the DDNS service.
3.
Click Submit . If you are finished making changes click Save and Restart .
Forcing a DDNS server update
To update the DDNS server with your IP address, click Update .
Configuring Dynamic Host Configuration Protocol (DHCP) Server
To view, add, or edit DHCP servers, see the IPv4 DHCP Servers (IPv4 support) or DHCPv6 and Router
Advertisement (for IPv6 support) list under Setup > DHCP Configuration.
You can configure multiple DHCP servers. Only one DHCP server can be created per LAN network interface. You can configure your device to function as DHCP server that supply network configuration information, such as IP address, subnet mask, and broadcast address, to devices on the network.
By default, the DHCP server is configured and enabled for Bridge ( br0 ) network interface. If a LAN network interface is NOT under the bridge, DHCP server can be configured and enabled for it..
DHCP Server is disabled automatically if you modify the network interface under Setup > Network Interface including: changes to the interface subnet adding network interface under the bridge changes the interface from LAN to WAN (Ethernet interface only) removes all LANs from under the bridge (DHCP for br0 will be disabled in this case)
DHCP Server cannot be enabled if the network interface is under the bridge, or is not enabled or configured properly (for example, when eth0 is configured as WAN, or Wi-Fi Access Point is disabled).
To edit the configuration of an existing IPv4 DHCP server or add a new one:
1.
Go to Setup > DHCP Configuration . See the IPv4 DHCP Servers list.
2.
To edit a DHCP Server , click the pencil icon (edit) for the selected interface, OR to add a DHCP Server , click the Add IPv4 DHCP Server button.
3.
The DHCP Configuration fields appear. To use the DHCP feature, check Enabled .
4.
In the Interface field, select the network interface. Note: Interface field is read-only when you edit DHCP
Server.
5.
The Subnet field displays the subnet address.
6.
The Mask field displays the network's subnet mask.
7.
In the Gateway field, type the gateway address.
48 mPower TM Edge Intelligence Conduit AEP Software Guide
SETUP
8.
In the Domain field, type your network domain, if any.
9.
In the Lease Time field, enter the DHCP lease time. Lease time is set in days, hours, and minutes (dd-hhmm). A Lease Time of 00-00-00 is an infinite lease time.
10.
In the Lease Range Start field and in the Lease Range End field, type the range of IP addresses to be assigned by DHCP.
11.
Click Submit . If you are finished making changes, click Save and Restart .
To edit the configuration of an existing DHCPv6 and Router Advertisement server or add a new one:
1.
Go to Setup > DHCP Configuration . See the DHCPv6 and Router Advertisement list.
2.
To edit a DHCP Server , click the pencil icon (edit) for the selected interface, OR to add a DHCP Server , click the Add DHCPv6/RA button.
3.
The DHCP Configuration fields appear. To use the DHCP feature, check Enabled .
4.
In the Interface field, select the network interface from the drop-down including eth0 and wlan1 .
Note:
Interface field is read-only when you edit DHCP Server.
5.
In the Router Advertisement Mode, select from the drop-down the DHCP IPv6 mode including SLAAC or
Stateless DHCP .
6.
In the Lease Time field, type the DHCP lease time. Lease time is set in days, hours, and minutes (dd-hhmm). A Lease Time of 00-00-00 is an infinite lease time.
7.
Click Submit . If you are finished making changes, click Save and Restart .
To add fixed addresses for the DCHP server, see Assigning Fixed Addresses .
Assigning Fixed Addresses
To add fixed addresses for the DCHP server make the changes under the Fixed Addresses section on the DCHP
Configuration page:
1.
In the MAC Address field, type the MAC address to which the specified IP address binds.
2.
In the IP Address field, type the fixed IP address to be assigned.
3.
Click Add .
4.
To save your changes, click Save and Restart .
Configuring SNMP
The device offers Simple Network Management Protocol (SNMP) which is used for collecting information from network devices on an IP network.
You also have the option to configure SNMP traps which are alerts sent from SNMP-enabled devices to an SNMP agent or manager typically providing device status or condition information.
You can also access the MIB file which is a management information base. This file is a formal description of a set of network objects managed using the Simple Network Management Protocol (SNMP). The format of the MIB is defined as part of the SNMP. (All other MIBs are extensions of this basic management information base.)
Click Download MIB , to download the MIB file.
To configure SNMP:
1.
Go to Setup > SNMP Configuration .
2.
Under SNMP Server Configuration , check Enabled to activate the SNMP server. Click Submit .
mPower TM Edge Intelligence Conduit AEP Software Guide 49
SETUP
3.
If needed, click Add under Allowed IP Addresses for SNMP v1/v2c .
4.
Click Add Server Configuration .
a.
Make sure that Enabled is checked.
b.
Under Version , select from the drop-down either SNMP v1/v2c or SNMP v3 .
c.
For SNMP v1 and SNMP v2c : i.
Enter the Configuration Name for your SNMP configuration.
ii.
Enter Community String which is a read-only string used to authenticate incoming SNMP requests.
d.
For SNMP v3 : i.
Enter the Authentication Protocol from the drop-down, including NONE, MD5 , or SHA1 .
ii.
Enter the Security Name which is a username used to authenticate incoming SNMP v3 requests. If you selected MD5 or SHA1 for Authentication Protocol:
Enter the Authentication Password , which is a password used to authenticate incoming SNMPv3 requests.
Confirm the password.
iii.
Enter the Encryption Protocol for SNMPv3 messages from the drop-down, including NONE, DES or AES-128 . If you selected DES or AES-128 for Encryption Protocol :
Enter the Encryption Password .
Confirm the password.
e.
Click Submit .
5.
The SNMP Configuration list displays your recently added SNMP Server Configuration. To edit the configuration, click the pencil icon under Options .
6.
To delete an existing configuration, click the trash can icon under Options .
7.
To save your changes, click Save and Restart . Or continue to SNMP Trap Destinations and Add Trap
Destinations .
To configure SNMP Traps:
1.
Go to Setup > SNMP Configuration > SNMP Trap Configuration , check Enabled to enable sending SNMP traps on the device..
2.
The engine ID displays to the right of Enabled . Modify the engine ID or use the default value.
3.
Click Submit.
4.
Click Add Trap Destination .
a.
Make sure that Enabled box is checked.
b.
Enter the Destination Name.
c.
Select from the drop-down the Version of SNMP ( SNMP v1/v2c or SNMP v3 ).
d.
For SNMP v1 or SNMP v2c i.
Enter the Destination IP Address .
ii.
Enter the Community String .
e.
For SNMPv3 :
50 mPower TM Edge Intelligence Conduit AEP Software Guide
SETUP i.
Enter the Destination IP Address .
ii.
Enter Security Name .
iii.
Enter the Authentication Protocol from the drop-down, including NONE, MD5, or SHA1 . If you selected MD5 or SHA1 for Authentication Protocol : i.
Enter the Authentication Password , which is a password used to authenticate incoming
SNMPv3 requests.
ii.
Confirm the password.
iii.
Enter the Encryption Protocol for SNMPv3 messages from the drop-down, including NONE,
DES , or AES-128 . If you selected DES or AES-128 for Encryption Protocol: i.
Enter the Encryption Password .
ii.
Confirm the password.
f.
Click Submit .
5.
The SNMP Trap Destination list displays your recently added SNMP Trap Destination. To edit the destination, click the pencil icon under Options .
6.
To delete an existing destination, click the trash can icon under Options .
7.
To save your changes, click Save and Restart .
To download the MIB file:
1.
Click Download MIB in the far right corner of the device display.
2.
Download/save the file from your browser.
Configuring the Global Positioning System (GPS)
This GPS information applies only to the device models that support GPS.
Some devices have a built-in GPS receiver. If your device has a GPS receiver, the device can forward NMEA
(National Marine Electronics Association) sentences from the GPS receiver to another device connected to the device. You can also send the GPS data over the network to a remote computer.
The key areas of GPS configuration include: Server Configuration , Client Configuration and NMEA Configuration along with Current Position information.
Notes:
All enabled sentences are forwarded periodically using the interval specified in the NMEA Configuration section. Before forwarding, the device adds an ID prefix and ID to each enabled NMEA sentence. If set, the
NMEA sentences available are those provided by the built-in receiver which are: GPGGA, GPGSA, GPGSV,
GPGLL, GPRMC, GPVTG.
You can simultaneously enable the TCP Server, and TCP/UDP client.
GPS Server Configuration
To setup the GPS Server Configuration:
1.
Go to Setup > GPS Configuration > Server Configuration .
2.
To enable server configuration, check TCP Server .
mPower TM Edge Intelligence Conduit AEP Software Guide 51
SETUP
3.
In the Port field, type the port number on which the TCP server is listening for connections. The default is
5445 . You can use up to five digits. Each digit itself must be between 0 and 9 . Numbers above 65,535 are illegal as the port identification fields are 16 bits long in the TCP header.
4.
Enter Password and confirm Password .
5.
Click Submit .
6.
To save your changes, click Save and Restart .
Sending GPS information to a remote server
The Client Configuration allows the device to connect to a remote server using the IP and port information for uploading GPS data.
1.
To allow the device to connect, go to Setup > GPS Configuration > Client Configuration .
2.
Check TCP/UDP Client .
3.
From the Protocol drop-down list, select the protocol of the client ( TCP or UDP ).
4.
In the Remote Host field, type the IP address of the remote host.
5.
In the Port , field type the port number of the remote host.
6.
If your remote host requests a password, type that password in the Password field. The password is sent to the server in response.
7.
Click Submit .
8.
To save your changes, click Save and Restart .
Configuring NMEA Sentences
To configure the time interval, additional prefix or ID information, and which NMEA sentences that can be sent:
1.
Go to Setup > GPS Configuration > NMEA Configuration .
2.
If Enable NMEA Mode exists (disabled by default), check to enable.
NOTE: GLL and VTG sentences cannot be enabled when NMEA Mode is disabled.
3.
In the Interval field, type the amount of time, in seconds, that passes before the NMEA information is sent. The default is 10 seconds. The range is 1 to 255 seconds.
4.
You can further identify the device, also called a remote asset, that is collecting and sending the GPS information. To do so:
Add ID : The ID is an unique remote asset identification string. The ID string can be any length up to 20 characters. The & and $ are invalid characters. The ID must follow the standard NMEA sentence structure.
Refer to the Universal IP AT Commands Reference Guide for sentence structure.
To add more information to the beginning of the ID, in the Add ID Prefix field, type the information.
5.
For devices that do not have Enable NMEA Mode , you can select which NMEA sentence types you want to send. Check any combination of the available options: GGA, GSA, GSV, GLL, RMC, and VTG .
SMTP Settings
The following table lists the configuration fields in the SMTP window.
Description Field
SMTP Configuration
Enabled Click to use the SMTP feature.
52 mPower TM Edge Intelligence Conduit AEP Software Guide
SETUP
Field
Server
Port
Description
Enter the SMTP server address.
Enter the port number that the SMTP server uses.
Enter the sender email address. This address will be added as the sender email address to the sent emails.
Enter the name that can access the SMTP server.
Enter the password that can access the SMTP server.
Username
Password
Mail Log Settings
Entries to Keep Enter the desired number of mail log entries that are to be stored in the device. The range of values is 10 to 1000 . If you click Submit , this setting is not applied to the emails that are in progress or deferred. Note that logs are not saved on the device. Also, logs do not persist through power cycles.
Send a Test Email
Address To make sure that the SMTP is configured properly, enter a destination email address, then click Send Test Email .
Configuring the Serial Port in Serial IP Mode
This features requires installation and configuration of mCard Accessory Card (such as an MTAC-MFSER) into your device first. To configure the serial terminal connected to the RS-232 connector on your accessory card:
1.
Go to Setup > Serial IP Configuration > Serial Port Settings , check Enabled .
2.
From the Baud Rate drop-down list, select the baud-rate at which the serial terminal communicates. The default is 115200 .
3.
From the Flow Control drop-down list, select the flow control for the serial port. The options are NONE or
RTS-CTS . The default is NONE .
4.
From the Parity drop-down list, select the parity for the serial port. The options are NONE, EVEN, or ODD .
The default is NONE .
5.
To use the Modbus protocol as the protocol the serial devices use to communicate, check Modbus
Gateway to the right of Enabled .
NOTE: You may have the TCP connection encrypted with TLS. Make sure to check Protocol under IP Pipe and select SSL/TLS .
6.
From the Data Bits drop-down list, select the data bits for the serial port. Data bit options are 7 or 8 . The default is 8 .
7.
From the Stop Bits drop-down list, select the stop bits for the serial port. The options are 1 or 2 . The default is 1.
8.
Click Submit .
9.
To save your changes, click Save and Restart .
Configuring Device to Act as Client for Serial IP
You can set up the device to act as a client.
mPower TM Edge Intelligence Conduit AEP Software Guide 53
SETUP
The TCP, UDP, SSL/TLS client feature enables the device to act as a proxy TCP, UDP, or SSL/TLS client to the serial terminal connected to the RS-232 port on the device. This helps the serial terminal access any TCP, UDP, or SSL/TLS server on the LAN/WAN allowing two-way traffic between the serial device and the remote server.
To use this function, you must first check Enabled under Serial Port Settings . To configure the IP Pipe in TCP, UDP, or SSL/TLS client mode:
1.
Go to Setup > Serial-IP Configuration > Serial Port Settings > IP Pipe group.
2.
From the Mode drop-down list, select CLIENT .
3.
From the Protocol drop-down list, select the desired protocol: TCP , UDP , or SSL/TLS .
4.
In the Server IP Address field, enter the address of the far-end TCP, UDP, or SSL/TLS server.
5.
In the Server Port field, enter the port value used by the far-end TCP, UDP, or SSL/TLS server.
6.
If the primary server is unavailable, in the Secondary IP Address field, enter the address of the alternate
TCP, UDP, or SSL/TLS server.
7.
If the primary server is unavailable, in the Secondary Port field, enter port number value of the alternate
TCP, UDP, or SSL/TLS server.
8.
From the Connection Activation drop-down list, select a connection method. Options are:
ALWAYS-ON .
CR . Three carriage returns must be received before the TCP, UDP, or SSL/TLS connection is established to the remote server.
ON-DEMAND . Set the connection as available on-demand.
9.
From the Connection Termination drop-down list, select a disconnect method for the IP pipe. Options are:
ALWAYS-ON .
TIMEOUT . The IP pipe connection disconnects if the configured timer expires with no data sent or received. In the Timeout field, enter the desired number of seconds for this timeout. The valid timeout range is from 0 to 900 seconds . Timeout of zero seconds disables the timeout and it is equivalent to
ALWAYS-ON .
SEQUENCE . A sequence of received characters disconnects the IP pipe.
10.
In the Buffer Timeout field, enter the timeout after which data is sent to the network if the buffer is not full (in milliseconds).
11.
In the Buffer Size field, enter the size of the buffer for reading data from the serial port and sending to the network (in bytes). Data is sent when the buffer is full.
12.
Click Submit .
13.
To save your changes, click Save and Restart .
To configure security settings:
1.
Make sure you select SSL/TLS under Protocol .
2.
Under Security Settings , click the Show to the right.
3.
By default, the Use default cipher suite is checked. If you accept this default, no other action is needed.
4.
Uncheck this box, if you want to select specific TLS versions and Cipher Suites. These fields appear.
5.
Select the TLS version . Check either TLSv1.2
or TLSv1.1
.
54 mPower TM Edge Intelligence Conduit AEP Software Guide
SETUP
6.
Check your preferred Cipher Suite from the following list: ECDHE-RSA-AES256-GCM-SHA384, ECDHE-RSA-
AES256-SHA, DHE-RSA-AES256-GCM-SHA384, AES256-SHA, ECDHE-RSA-AES128-GCM-SHA256, ECDHE-
RSA-AES128-SHA, DHE-RSA-AES128-GCM-SHA256, DHE-RSA-AES128-SHA, and/or AES128-SHA
7.
Click Submit .
8.
To save your settings, click Save and Restart .
Configuring Device to Act as Server for Serial IP
You can set up the device to act as a server.
The TCP, UDP, SSL/TLS server feature enables a TCP, UDP, SSL/TLS client on the Ethernet network to connect to the remote serial terminal that is connected to the RS-232 port on the device. The device acts as a TCP, UDP, SSL/TLS server which allows two-way traffic between the TCP, UDP, SSL/TLS client and the remote terminal on the serial port.
To use this function, you must first check Enabled under Serial Port Settings . To configure the IP Pipe in TCP, UDP,
SSL/TLS server mode:
1.
Go to Setup > Serial-IP Configuration > Serial Port Settings > IP Pipe group.
2.
In the Mode drop-down list, select SERVER .
3.
From the Protocol drop-down list, select the desired protocol: TCP , UDP , or SSL/TLS .
4.
In the Buffer Timeout field, enter the timeout after which data is sent to the network if the buffer is not full (in milliseconds).
5.
In the Server Port field, type the desired port value in the range 1 to 65535 .
6.
In the Buffer Size field, enter the size of the buffer for reading data from the serial port and sending to the network (in bytes). Data is sent when the buffer is full.
7.
From the Connection Termination drop-down list, select a disconnect method for the IP pipe. Options are:
ALWAYS-ON .
TIMEOUT . The IP pipe connection disconnects if the configured timer expires with no data sent or received. In the Timeout field, enter the desired number of seconds for this timeout. The valid timeout range is from 0 to 900 seconds . Timeout of zero seconds disables the timeout and it is equivalent to
ALWAYS-ON.
SEQUENCE . A sequence of received characters disconnects the IP pipe.
8.
Click Submit .
9.
To save your changes, click Save and Restart .
To configure security settings:
1.
Make sure you select SSL/TLS under Protocol .
2.
Under Security Settings , click the Show to the right.
3.
By default, the Use default cipher suite is checked. If you accept this default, no other action is needed.
4.
Uncheck this box, if you want to select specific TLS versions and Cipher Suites. These fields appear.
5.
Select the TLS version . Check either TLSv1.2
or TLSv1.1
.
mPower TM Edge Intelligence Conduit AEP Software Guide 55
SETUP
6.
Check your preferred Cipher Suite from the following list: ECDHE-RSA-AES256-GCM-SHA384, ECDHE-RSA-
AES256-SHA, DHE-RSA-AES256-GCM-SHA384, AES256-SHA, ECDHE-RSA-AES128-GCM-SHA256, ECDHE-
RSA-AES128-SHA, DHE-RSA-AES128-GCM-SHA256, DHE-RSA-AES128-SHA, and/or AES128-SHA
7.
Click Submit .
8.
To save your settings, click Save and Restart .
Time Configuration
You can configure how your device manages the setting of time on its domain of systems. The system date and time display in these formats: MM/DD/YYYY HH:MM . You can set the date and time manually, or you can configure the device to get this information from an SNTP server.
Setting the Date and Time
To set the device's date and time:
1.
From Setup , select Time Configuration .
2.
In the Date field, select today's date from the pop-up calendar that opens.
3.
In the Time field, type the time (24-hour).
4.
From the Time Zone drop-down list, select your time zone. The default selection is UTC (Universal
Coordinated Time, Universal Time).
Note: To learn more about time zones, visit the following website : http://wwp.greenwichmeantime.com/info/current-time.htm
5.
Click Submit .
6.
To save your changes, click Save and Restart .
Configuring SNTP Client to Update Date and Time
To configure the server from which the SNTP date and time information is taken, and how often:
1.
To enable SNTP to update the date and time, check Enabled .
2.
In the Polling Time field, type the time that passes (in minutes), after which the SNTP client requests the server to update the time. Default is 120 minutes.
3.
In the Server field, type the SNTP server name or IP address that is contacted to update the time.
4.
In the Backup Server 1 -4 fields, you may enter the SNTP server name or IP address of up to four backup
SNTP servers. These fields are optional.
5.
Click Submit .
6.
To save your changes, click Save and Restart .
56 mPower TM Edge Intelligence Conduit AEP Software Guide
WIRELESS
Chapter 6 – Wireless
Setting Up Wi-Fi Access Point
If you ordered a device with Wi-Fi capability, it can be configured as a wireless access point (AP). This allows Wi-Fi enabled devices to connect to your device using Wi-Fi. The Wi-Fi access point can have up to 5 clients at a time. To set up your device as an access point:
1.
Go to Wireless > Wi-Fi Access Point .
2.
To enable Wi-Fi Access Point mode, check Enabled .
3.
To set the SSID (service set identifier) for the access point supported by your device, in the SSID field, type the name. The Wi-Fi devices look for this ID in order to join the wireless network. All wireless devices on a WLAN must use the same SSID in order to communicate with the access point.
4.
To specify the data rates supported, in the Network Mode drop-down list, select the desired option.
Possible values are B/G/N-Mixed, B/G-Mixed, B-Only, and N-Only.
5.
From the Channel drop-down list, select the channel on which the device operates. Channels 1-11 are available.
6.
In the Beacon Interval field, enter the period of time, in milliseconds, when the access point sends a beacon packet. Beacons help synchronize a wireless network. For most applications, the default value of
100 provides good performance.
7.
In the DTIM Interval field, enter how often a beacon frame includes a Delivery Traffic Indication Message, and this number is included in each beacon frame. It is generated within the periodic beacon at a frequency specified by the DTIM Interval. A delivery traffic indication message is a kind of traffic indication message (TIM) which informs the clients about the presence of buffered multicast/broadcast data on the access point. The default value of 1 provides good performance for most applications. You might want to increase this value when using battery powered Wi-Fi devices, which can sleep (at reduced power consumption) during the longer DTIM interval period. You must balance the power savings from increasing the DTIM interval against possible reduced communication throughput.
8.
In the RTS Threshold field, type the frame size at which the AP transmissions must use the RTS/CTS protocol. This is often used to solve hidden node problems. Using a small value causes RTS packets to be sent more often, consuming more of the available bandwidth. However, the more RTS packets that are sent, the quicker the system can recover from interference or collisions.
For related information, see
and
Viewing Information About Wi-Fi Clients Using Your Wireless
.
Setting Security Options
Specify the security protocol that your device uses to secure the communications from it to the connected devices under Security Options .
1.
From the Mode drop-down list, select the security protocol you want to use. Options include:
None
WEP : Use Wired Equivalent Privacy protocol to allow a group of devices on the network to exchange coded messages.
WPA-PSK : Use Wi-Fi protected access to secure data exchanged on your network.
WPA2-PSK : Use Wi-Fi protected access version 2 to secure data exchanged on your network.
WPA/WPA2-PSK : Use Wi-Fi protected access version 1 and 2 to secure data exchanged on your network.
mPower TM Edge Intelligence Conduit AEP Software Guide 57
WIRELESS
58
2.
To select WEP mode: a.
From the Encryption drop-down list, select the encryption to be used. Choose from 64 bit 10 hex digits or 128 bit 26 hex digits .
b.
To generate a key from a phrase, in the Passphrase field, type a phrase. Click Generate .
c.
To manually enter keys, type the keys in the Key 1, Key 2, Key 3 or Key 4 fields.
3.
To select WPA-PSK, WPA2-PSK or WPA-PSK/WPA2-PSK modes: a.
Select the WPA Algorithm from the drop-down list. Choose from TKIP, AES or TKIP+AES .
b.
In the Shared Key field, type the key that is used for encrypting and decrypting the data.
c.
To remove the mask characters, thereby making the Shared Key visible, check Unmask .
4.
When done, click Submit .
5.
To save your changes, click Save and Restart .
Viewing Information About Wi-Fi Clients Using Your Wireless Network
To view information about clients (such as computers, tablets, and smart phones) that are connected to your device's Wi-Fi access point:
1.
The Clients group displays a list of clients using your device's Wi-Fi.
2.
To update the list, click Refresh .
Setting Up Wi-Fi as WAN
To setup the device's Wi-Fi as WAN:
1.
Go to Wireless > Wi-Fi as WAN.
2.
To enable Wi-Fi as WAN mode, check Enabled .
3.
Click Save and Restart .
Note : Save and Restart the device to get a list of available Wi-Fi Networks.
4.
Go to Wireless > Wi-Fi as WAN .
5.
Searching for available Wi-Fi networks starts automatically. After 30 to 60 seconds, a list of detected Wi-
Fi Access Points appears in the Available Networks group.
6.
In the Available Wi-Fi Networks group, click the SSID for the Wi-Fi access point you want to use. The Add
Saved Network window opens. Here are the available fields to enter information:
Network Name
Hidden Network (only check if your target network is currently hidden)
SSID
Security Mode: None, WEP, WPA, WPA-PSK, WPA-2 , or WPA-2-PSK
Username
Password
Unmask (Check, Uncheck)
WPA Algorithm: TKIP, +AES, TKIP , or AES
Shared Key
Key Index: 0 - 3
Network Key
IEEE 802.1x
mPower TM Edge Intelligence Conduit AEP Software Guide
WIRELESS
7.
Review the information, enter any required security info, then click Finish . The Wi-Fi access point you just added appears in the Saved Wi-Fi Networks group.
8.
If desired, add additional access points to the list of Saved Networks. The device tries to connect to Saved
Wi-Fi Networks in the order they are listed. You can change the order by clicking the up or down arrows shown under Options .
9.
When finished, click Save and Restart . The Status field displays "Connected" if you have successfully connected to the Wi-Fi access point.
Note: You cannot edit the network name and you cannot delete a network if it is used in another configuration.
Setting up Bluetooth
The Bluetooth-IP feature allows a data connection between a remote TCP/UDP client or server and a local
Bluetooth device. To set up the Bluetooth connection:
1.
Go to Wireless > Bluetooth-IP
2.
To enable the feature, check Enabled . Click Submit .
3.
Confirm that the far-end Bluetooth device is powered on and waiting for a connection.
4.
In the Available Devices group, click Refresh . A list of detected Bluetooth devices appears.
5.
Click the name of the Bluetooth device that you want to use. The name and MAC address appear under the Selected Device .
6.
To add a device, click Add Device and enter the device name and the MAC address .
7.
Click Finish .
8.
To save your changes, click Save and Restart .
Note: You cannot edit the network name and you cannot delete a network if it is used in another configuration.
IP Pipe in TCP/UDP Server mode
1.
In the IP Pipe group, from the Mode drop-down list, select SERVER .
2.
From the Protocol drop-down list, select the desired protocol, either TCP or UDP .
3.
In the Server Port field, type the desired port value in the range 1 to 65535 .
4.
From the Connection Termination drop-down list, select a disconnect method for the IP pipe. Options are:
ALWAYS-ON
SEQUENCE: A sequence of characters received from the Bluetooth side used to disconnect the IP pipe.
TIMEOUT: The IP pipe connection disconnects if the configured timer expires with no data sent or received. A timeout of zero seconds disables the timeout, it is equivalent to ALWAYS-ON .
To configure the IP Pipe in TCP/UDP Client mode
1.
In the IP Pipe group, from the Mode drop down list, select CLIENT .
2.
From the Protocol drop-down list, select the desired protocol, either TCP or UDP .
3.
In the Server IP Address field, type the address of the far-end TCP-UDP server.
4.
In the Server Port field, type the port value used by the far-end TCP/UDP Server.
5.
In case the primary server is unavailable, in the Secondary IP Address field and in the Secondary Port field, type the IP address and port number, respectively, of the alternate TCP/UDP server.
6.
From the Connection Activation drop-down list, select a connection method. Options are: mPower TM Edge Intelligence Conduit AEP Software Guide 59
WIRELESS
60
ALWAYS-ON
ON-DEMAND
CR: Three carriage returns must be received from the Bluetooth side before TCP/UDP connection is established to the remote server.
7.
From the Connection Termination drop-down list select a disconnect method for the IP pipe. Options are:
ALWAYS-ON:
TIMEOUT: The IP pipe connection disconnects if the configured timer expires with no data sent or received. A timeout of zero seconds disables the timeout, it is equivalent to ALWAYS-
ON .
SEQUENCE: A sequence of characters received from the Bluetooth side used to disconnect the
IP pipe.
8.
Click Submit .
9.
To save your changes, click Save and Restart .
The device immediately connects to the local Bluetooth device. If successful the Status field displays Connected . If IP Pipe is configured for SERVER , the IP connection is initiated by the far-end TCP/UDP client.
If Mode is set to CLIENT , the device initiates connections for the far-end TCP/UDP server based on the configured Connection Activation conditions are met.
To configure security settings :
1.
Make sure you select SSL/TLS under Protocol .
2.
Under Security Settings , click the Show to the right.
3.
By default, the Use default cipher suite is checked. If you accept this default, no other action is needed.
4.
Uncheck this box, if you want to select specific TLS versions and Cipher Suites. These fields appear.
5.
Select the TLS version . Check either TLSv1.2
or TLSv1.1
.
6.
Check your preferred Cipher Suite from the following list: ECDHE-RSA-AES256-GCM-SHA384, ECDHE-RSA-
AES256-SHA, DHE-RSA-AES256-GCM-SHA384, AES256-SHA, ECDHE-RSA-AES128-GCM-SHA256, ECDHE-
RSA-AES128-SHA, DHE-RSA-AES128-GCM-SHA256, DHE-RSA-AES128-SHA, and/or AES128-SHA
7.
Click Submit .
8.
To save your settings, click Save and Restart .
Bluetooth Low Energy (BLE)
Bluetooth Low Energy allows you to search and/or scan for BLE devices. You can connect with selected BLE device to obtain the list of UUIDs for services and characteristics that are supported on the device.
A python library called gattlib is integrated into the device and can be used for scans, reads, writes, and handling notifications.
You must develop a custom application to read and accept the data from a BLE device. Please refer to the example on the BLE for mLinux page as well as the Creating a Custom Application page.
1.
Go to Wireless > Bluetooth Low Energy > Settings , check the Enabled box.
2.
Under Power Mode , select from the drop-down including Custom, High, Medium or Low .
3.
Click Submit.
4.
Under the Available Device Servers , the detected BLE devices appear.
mPower TM Edge Intelligence Conduit AEP Software Guide
WIRELESS
5.
To choose a device from the Available Device Servers , click on the name of your desired device.
6.
If you do not see your desired device, click Add Device.
Enter the Name and MAC Address of your BLE device.
7.
Click OK . Your device appears under Saved Devices .
8.
Click Save and Restart to save your changes.
You may also restart BLE by clicking Reset Bluetooth above Saved Devices section.
mPower TM Edge Intelligence Conduit AEP Software Guide 61
FIREWALL
Chapter 7 – Firewall
Defining Firewall Rules
The device's firewall enforces a set of rules that determine how incoming and outgoing packets are handled. By default, all outbound traffic originating from the LAN is allowed to pass through the firewall, and all inbound traffic originating from external networks is dropped. This effectively creates a protective barrier between the LAN and all other networks.
The firewall is built on top of iptables. The different rule groups correspond to their respective chains in iptables.
Note: As a best security practice, the device employs minimum firewall rules by default. This means by default the device allows all outbound traffic from it in the Output Filter Rules. (Traffic through the device is handled by the
Port/Inbound Forwarding Rules.) But all traffic to the device via WAN interfaces is blocked by default in the Input
Filter Rules. Users may create their own specific and targeted input filter rules to allow certain traffic to the device based on their specific needs. For additional information, see:
Trusted IP
Trusted IP is a simplified interface to create iptables rules to allow or block specific IPs, IP ranges, or subnets. This feature allows users to create whitelists (which are allowed or trusted IPs) or black lists (which are blocked or unwanted IPs). You can add, edit, and delete IP addresses as needed.
If you select White List as Trusted IP Mode and you do not set any IP range, no traffic will be allowed. If you select
Black List as Trusted IP Mode and you do not set any IP range, all traffic will be allowed.
To set up a Trusted IP range:
1.
Go to Firewall > Trusted IP .
2.
Check the Enabled box to turn on Trusted IP.
3.
Select the Trusted IP Mode from the drop-down, either White List or Black List . ( NOTE : Be aware of the behavior of each list and its consequences based on your specific configuration. For example, if you select
White List as Trusted IP Mode , you should include the device IP Address Range or IP Address and Subnet
Mask to maintain your local device LAN access.)
4.
To add IP addresses, click Add IP Range in the upper right corner.
5.
Under the Add IP Range , enter or select the following parameters: a.
Name b.
Mode from drop-down, either Subnet or IP Range .
c.
For Subnet : i.
IP Address ii.
Subnet Mask d.
For IP Range :
62 mPower TM Edge Intelligence Conduit AEP Software Guide
FIREWALL i.
IP Address Start ii.
IP Address End e.
Destination Port (default: ANY ) f.
Protocol from drop-down including ANY, TCP/UDP, TCP , or UDP g.
Click Finish .
6.
The system displays your recently added and existing IP ranges in a list. The list includes the relevant details. You may edit any IP ranges by clicking on the pencil icon under Options .
7.
You may delete any IP ranges by clicking on the trash can icon under Options .
8.
If you want to revert back to default settings (where Trusted IP is disabled and all IP ranges are removed), click the Reset to Default button in the lower right corner
9.
Click Submit .
10.
To save your changes, click Save and Restart .
Prerouting Rule
Add a DNAT rule
To add prerouting or DNAT rule to your firewall:
1.
Go to Firewall > Settings to display the Firewall window.
2.
In the Prerouting Rules group, click Add DNAT Rule .
3.
In the Filter Rule section, enter a name for the rule and optionally, a description.
4.
In the Destination IP field, enter the destination IP address that applies to this rule.
5.
In the Destination Port field, enter the destination port that applies to this rule. If there is a range of ports, the ending port is automatically set.
6.
In the Destination Mask field, enter the subnet mask of the destination that applies to this rule.
7.
In the Destination Interface field, select the interface used by the destination that applies to this rule from the drop-down menu. Select from ANY, LAN, WAN, ETHERNET, CELLULAR, WI-FI WAN, WI-FI AP, or
OPENVPN .
8.
In the Source IP field, enter the source IP address that applies to this rule.
9.
In the Source Port field, enter the source port that applies to this rule.
10.
In the SourceMask field, enter source subnet mask that applies to this rule.
11.
In the SourceMAC field, enter the source MAC address for the device that applies to this rule.
12.
In the SourceInterface field, select the source interface that applies to this rule from the drop-down menu. Select from ANY, LAN, WAN, ETHERNET, CELLULAR, WI-FI WAN, WI-FI AP, or OPENVPN .
13.
In the Protocol drop-down list, select the protocol of the messages that apply to this rule. Select from
TCP/UDP , TCP , UDP , or ANY .
14.
In the NAT IP field, enter the public IP address for the Network Address Translation.
15.
In the NAT Port field, enter the port used publicly for the Network Address Translation.
16.
Check Enable NAT Loopback if you want to redirect LAN packets destined for the WAN's public IP address.
17.
Click Submit .
18.
To save your changes, click Save and Restart .
mPower TM Edge Intelligence Conduit AEP Software Guide 63
FIREWALL
64
Postrouting Rule
Add a SNAT rule
To add postrouting or SNAT rule to your firewall:
1.
Go to Firewall > Settings to display the Firewall window.
2.
In the Postrouting Rules group, click Add SNAT Rule .
3.
In the Postrouting Rule section, enter a name for the rule and optionally, a description.
4.
In the Destination IP field, enter the destination IP address that applies to this rule.
5.
In the Destination Port field, enter the destination port that applies to this rule. If there is a range of ports, the ending port is automatically set.
6.
In the Destination Mask field, enter the subnet mask of the destination that applies to this rule.
7.
In the Destination Interface field, select the interface used by the destination that applies to this rule from the drop-down menu. Select from ANY, LAN, WAN, ETHERNET, CELLULAR, WI-FI WAN, WI-FI AP, or
OPENVPN .
8.
In the Source IP field, enter the source IP address that applies to this rule.
9.
In the Source Port field, enter the source port that applies to this rule.
10.
In the SourceMask field, enter source subnet mask that applies to this rule.
11.
In the SourceMAC field, enter the source MAC address for the device that applies to this rule.
12.
In the SourceInterface field, select the source interface that applies to this rule from the drop-down menu. Select from ANY, LAN, WAN, ETHERNET, CELLULAR, WI-FI WAN, WI-FI AP, or OPENVPN .
13.
In the Protocol drop-down list, select the protocol of the messages that apply to this rule. Select from
TCP/UDP , TCP , UDP , or ANY .
14.
In the NAT IP field, enter the public IP address for the Network Address Translation.
15.
In the Target field, select the desired action of the firewall based on this rule from the drop-down menu.
Choose from SNAT or MASQUERADE .
16.
In the NAT Port field, enter the port used publicly for the Network Address Translation.
17.
Click Submit .
18.
To save your changes, click Save and Restart .
Input Filter Rules
To add an input filter rule to your firewall:
1.
Go to Firewall > Settings to display the Firewall window.
2.
In the Input Filter Rules group, click Add Rule .
3.
In the Filter Rule section, enter a name for the rule and optionally, a description.
4.
In the Destination IP field, enter the destination IP address that applies to this rule.
5.
In the Destination Port field, enter the destination port that applies to this rule. If there is a range of ports, the ending port is automatically set.
6.
In the Destination Mask field, enter the subnet mask of the destination that applies to this rule.
7.
In the Destination Interface field, select the interface used by the destination that applies to this rule from the drop-down menu. Select from ANY, LAN, WAN, ETHERNET, CELLULAR, WI-FI WAN, WI-FI AP, or
OPENVPN .
8.
In the Source IP field, enter the source IP address that applies to this rule.
9.
In the Source Ports field, enter the source port range that applies to this rule.
mPower TM Edge Intelligence Conduit AEP Software Guide
FIREWALL
10.
In the Source Mask field, enter source subnet mask that applies to this rule.
11.
In the Source MAC field, enter the source MAC address for the device that applies to this rule.
12.
In the Source Interface field, select the source interface that applies to this rule from the drop-down menu. Select from ANY, LAN, WAN, ETHERNET, CELLULAR, WI-FI WAN, WI-FI AP, or OPENVPN .
13.
In the Protocol drop-down list, select the protocol of the messages that apply to this rule. Select from
TCP/UDP , TCP , UDP , or ANY .
14.
In the Chain field, select the grouping based on the type of traffic affected by the rule from the dropdown menu. Select from INPUT, FORWARD, or OUTPUT .
15.
In the Target field, select the desired action of the firewall based on this rule from the drop-down menu.
Choose from ACCEPT, REJECT, DROP, or LOG .
16.
Click Submit .
17.
To save your changes, click Save and Restart .
Inbound Forwarding Rule
Adding Port Forwarding Rules
For a device within the LAN to be visible from the internet or from an outside network, create a forwarding rule to allow incoming packets to reach the device.
1.
Go to Firewall > Settings to display the Firewall window.
2.
In the Port Forwarding group, click Add Rule .
3.
In the Filter Rule section , enter a name for the rule and optionally, a description.
4.
In the Destination IP field, enter the destination IP address that applies to this rule.
5.
In the Destination Port field, enter the destination port that applies to this rule. If there is a range of ports, the ending port is automatically set.
6.
In the Destination Mask field, enter the subnet mask of the destination that applies to this rule.
7.
In the Destination Interface field, select the interface used by the destination that applies to this rule from the drop-down menu. Select from ANY, LAN, WAN, ETHERNET, CELLULAR, WI-FI WAN, WI-FI AP, or
OPENVPN.
8.
In the Source IP field, enter the source IP address that applies to this rule.
9.
In the Source Ports field, enter the source port range that applies to this rule.
10.
In the Source Mask field, enter source subnet mask that applies to this rule.
11.
In the Source MAC field, enter the source MAC address for the device that applies to this rule.
12.
In the Source Interface field, select the source interface that applies to this rule from the drop-down menu. Select from ANY, LAN, WAN, ETHERNET, CELLULAR, WI-FI WAN, WI-FI AP, or OPENVPN .
13.
In the Protocol drop-down list, select the protocol of the messages that apply to this rule. Select from
TCP/UDP , TCP , UDP , or ANY .
14.
In the Chain field, select the grouping based on the type of traffic affected by the rule from the dropdown menu. Select from INPUT, FORWARD, or OUTPUT .
15.
In the Target field, select the desired action of the firewall based on this rule from the drop-down menu.
Choose from ACCEPT, REJECT, DROP, or LOG .
16.
Click Submit .
17.
To save your changes, click Save and Restart .
mPower TM Edge Intelligence Conduit AEP Software Guide 65
FIREWALL
A default filter allowing forwarded packets through the firewall is automatically created. If desired, you can use the
Advanced Settings mode of the Port Forwarding configuration to further restrict packets based on source address and source ports using the Inbound Filter Rule . In most cases, this is not necessary.
Output Filter Rules
To prevent a device within the LAN from communicating with a device in an external network, you must establish a firewall rule to drop packets destined to the external device.
1.
Go to Firewall > Settings to display the Firewall window.
2.
Click Add Rule in the Output Filter Rules section.
3.
Enter a Name for the rule and optionally, a Description .
4.
In the Destination IP field, type the IP address of the device or network that packets are to be sent to.
Type ANY if the destination address does not matter.
5.
In the Destination Port field, type the port for which that the packets are destined. Common destination ports are listed in the Destination Port field's attached drop down list. Type ANY if the destination port does not matter.
6.
In the Destination Mask field, type the network mask of the destination network.
7.
In the Destination Interface field, select the interface used by the destination that applies to this rule from the drop-down menu. Select from ANY, LAN, WAN, ETHERNET, CELLULAR, WI-FI WAN, WI-FI AP, or
OPENVPN .
8.
In the Source IP field, type the IP address of the device or network that the traffic originates from. Type
ANY if the source address does not matter.
9.
In the Source Port field, type the port that is the origin of the traffic. Type ANY if the source port does not matter.
10.
In the Source Mask field, type a network mask for the origin of the traffic.
11.
In the SourceMAC field, enter the source MAC address for the device that applies to this rule.
12.
In the Source Interface field, select the source interface that applies to this rule from the drop-down menu. Select from ANY, LAN, WAN, ETHERNET, CELLULAR, WI-FI WAN, WI-FI AP, or OPENVPN .
13.
From the Protocol drop-down list, select the protocol of the messages that apply to this rule. Choose from TCP/UDP , TCP , UDP , or ANY .
14.
In the Chain field, select the grouping based on the type of traffic affected by the rule from the dropdown menu. Select from INPUT, FORWARD, or OUTPUT .
15.
In the Target field, select the desired action of the firewall based on this rule from the drop-down menu.
Choose from ACCEPT, REJECT, DROP, or LOG .
16.
Click Submit .
17.
To save your changes, click Save and Restart .
Advanced Settings
The Firewall's Advanced Settings mode lets you manipulate DNAT, SNAT , and Filter rules directly.
DNAT rules can manipulate the destination address and port of a packet; similarly SNAT rules can manipulate the source address and port of a packet.
Filter rules apply an ACCEPT, REJECT, DROP , or LOG action to a packet. A DNAT or SNAT rule with the same name as a Forwarding rule will be associated under Normal Settings for Port Forwarding/NAT rules.
66 mPower TM Edge Intelligence Conduit AEP Software Guide
FIREWALL
Setting up Static Routes
To set up a manually configured mapping of an IP address to a next-hop destination for data packets:
1.
Go to Firewall > Static Routes .
2.
In the Static Routes window, click Add Route .
3.
In the Name field of the Add Route dialog box, type the name of the route.
4.
In the IP Address field, type the remote network IP address of the remote location.
5.
In the IP Mask field, type the network mask that is assigned on the remote location.
6.
In the Gateway field, type the IP address of the routing device that supports the remote IP Network.
7.
Click Finish .
8.
To save your changes, click Save and Restart .
mPower TM Edge Intelligence Conduit AEP Software Guide 67
CELLULAR
Chapter 8 – Cellular
Configuring Cellular
To configure how cellular is used on your device:
1.
Go to Cellular > Cellular Configuration to display the Cellular Configuration window.
2.
Check Enabled .
3.
Check and change the Cellular Configuration fields as desired. For field descriptions, see
.
4.
Click Submit .
5.
To save your changes, click Save and Restart .
Cellular Configuration Fields
Description Field
General Configuration
Enabled
Mode (varies with model)
Dial-on-Demand 1
Diversity(For H5, H6, LTE)
Connect Timeout
Dialing Max Retries
Cellular Mode (varies with model)
IPv4/IPv6 Address
IPv4/IPv6 Primary DNS
Allows the device to establish a cellular PPP or WWAN connection.
Choose from either PPP or WWAN for the cellular connection mode. (NOTE:
For some models, this field is not available and the device defaults to PPP.
Some fields described here are not used in WWAN mode.)
Enables the Dial-on-Demand feature. If enabled, the device brings up and maintains a cellular connection while network activity on the LAN requires
WAN access. The device brings down the cellular connection when outgoing network traffic ceases for the given Idle Timeout duration. Enable this feature when Wakeup-on-Call is enabled to allow the device to "sleep" after it has been "woken up." See Configuring Wakeup-on-Call for more information.
Allows the use of two antennas to increase receive signal quality. Not all models support diversity. If diversity is enabled, connect a second cellular antenna to the AUX port on the device. Otherwise, the cellular performance of the device may degrade.
The time (in seconds) that the device waits before it deems that the connection attempt has failed. The value used is the amount of time that elapses between each dialing retry.
Number of dialing retries allowed; the default is zero, which means an infinite number is allowed.
Select the Cellular Mode from the drop-down based on the cellular radio module in your device including: Auto (default), LTE Only, LTE prefer, 2G only, 3G only, or 3G prefer . NOTE: Values vary based on model. For some models, this field is not available.
The IP address of the device.
The IP address of the primary DNS server (optional).
68 mPower TM Edge Intelligence Conduit AEP Software Guide
CELLULAR
Field
Public IPv4 Mask
Modem Configuration
Firmware Image (Only available for specific models)
Description
The public mask for IPv4 (either 32 or 24).
Dial Number
Connect String
Dial Prefix
SIM Pin
APN
Init String#
Only available for specific radio models including -L4N1, -LNA3, or -MNG2.
Allows user to switch from one network carrier to another. Select from the drop-down either AT&T Compatible (default) , or Verizon for -L4N1. Select from the drop-down either Auto (default), AT&T Compatible, or Verizon for -
LNA3. Select from Auto (default), AT&T Compatible, Verizon, or World-Wide for -MNG2. The Auto option automatically detects your SIM and configures the device for the appropriate carrier.
The modem dial string is:
*99***1# for GSM/GPRS/non-Verizon LTE devices
The modem response to initiate a PPP connection, usually CONNECT .
The modem AT command that initiates a PPP connection, usually ATDT or
ATD .
The pin used to unlock the SIM for use (only required if the SIM is locked).
This does not apply to CDMA radios.
The Access Point Name assigned by the wireless service provider (carrier specific).
Optional fields to apply additional AT commands that execute just before every PPP connection attempt. Use these fields to expand functionality and to troubleshoot.
Authentication
Authentication Type The type of authentication to use when establishing a PPP connection:
NONE, PAP, CHAP, or PAP-CHAP (either). Authentication may not be required by the cellular service provider.
Username
Password
Name of the user that the remote PPP peer uses to authenticate.
Password that the remote PPP peer uses to authenticate.
Keep Alive 1
Used to periodically check if the cellular link is up; if not, the device tries to establish the link.
ICMP/TCP Check 1
An active check that provides the most reliable and reactive diagnosis of the cellular link, but requires sending data through the cellular link.
Enabled 1 Enables the Active Keep Alive check. Depending on the plan type and data usage, this may result in additional data charges.
Keep Alive Type 1 Protocol type for active keep alive, either TCP or ICMP .
ICMP periodically pings the designated host at the specified interval.
TCP tries to make a connection to the designated host at the interval specified.
Interval 1
Hostname 1
Time in seconds between active checking of the cellular link.
Host name or IP address for the keep alive check.
mPower TM Edge Intelligence Conduit AEP Software Guide 69
CELLULAR
Field
TCP Port 1
Description
TCP port number to connect with the TCP server (only visible when Keep
Alive Type TCP is selected).
ICMP Count 1 Number of sequential, unsuccessful ping attempts to the specified host to declare that the link needs to be re-established (only visible when Keep Alive
Type ICMP is selected).
Data Receive Monitor
A passive check that observes the absence of packets received over a given amount of time. This check cannot reliably determine if the link is down; no network traffic may cause the monitor to signal to shutdown and re-establish the cellular link even though the link was in a good state.
Enabled
Window
Enable or disable the passive monitoring of the cellular link.
The amount of time that can pass without receiving network traffic before the cellular link is torn down and re-established.
1 If you choose PPP-IP Passthrough and Serial Modem mode, this field is not available.
Configuring Wake Up On Call
This feature allows the device to wake up and initiate a cellular connection when there is an incoming call, SMS, or
LAN activity.
The Wake Up on Call function is not available for the LVW2 or Cat M1 devices (even though you can access those settings in the device software.)
1.
Go to Cellular > Wake Up On Call to display the configurations.
2.
Check the Wake Up On Call box.
3.
Select a Wake Up setting. For wakeup methods, see
Wake Up On Call Method Settings
.
4.
Click Submit .
5.
To save your changes, click Save and Restart .
Note: This feature only defines when the device brings up its cellular link, not when the device takes it down.
See the Dial on Demand option on the Cellular Configuration page at Cellular > Cellular Configuration to configure the criteria for bringing the cellular link down.
Wake Up On Call Method Settings
The triggers that wake up the device to re-establish the cellular link are:
On Ring:
Any incoming call will bring up the cellular link.
Enabled : Check to allow any incoming call to wake up the device.
Message : The expected response from the integrated cellular modem to an incoming call.
On Caller ID:
Only incoming calls in the caller ID list will bring up the cellular link.
Enabled : Check to allow a specific caller to wake up the device.
70 mPower TM Edge Intelligence Conduit AEP Software Guide
CELLULAR
Caller ID : Field to specify a caller ID. Enter the ID then click Add to add the caller to the approved caller
ID trigger list.
On SMS (not available if you enabled SMS through SMS > General Configuration ):
Only specific SMS messages will bring up the cellular link.
Enabled : Check to allow specific SMS messages to wake up the device.
Message : Field to specify the SMS message contents. Click Add to add the SMS message to the approved
SMS trigger list.
For Wake-Up-On-Call field descriptions, see
Wake Up On Call General Configurations
.
Wake Up On Call General Configurations
Field
Wake Up on Call check box
Dial On Demand LAN
Time Delay
Acknowledgment String to Caller
Init String Number
Description
Enables the Wake Up On Call feature.
When checked, the device allows network activity on the LAN that needs WAN access to trigger the Wake Up and establish the cellular link. If this configuration is not checked, the device will only establish a cellular connection when the selected Wake Up method is triggered via incoming call, caller ID, and/or short message service (SMS).
Time that passes between a receiving call and initiating the Wake Up On Call connection.
String used to acknowledge to the delivering SMSC
(short message service center) the receipt of an SMS.
Device initialization strings specific to the integrated cellular modem required for the Wake Up On Call feature.
mPower TM Edge Intelligence Conduit AEP Software Guide 71
CELLULAR
72
Radio Status
Field
Module Information
IMEI
IMSI
Manufacturer
Model
Description
International Mobile Station Equipment Identifier
International Mobile Subscriber Identifier
Company that developed the cellular module
Cellular module model number
Hardware Revision
MSID
Module's hardware revision
MDN (Phone Number) Mobile Directory Number. In some SIM/carriers, the value may not be present and therefore not displayed.
Mobile Station ID. Some SIM/carriers do not contain this value and therefore the value is not displayed.
Firmware Version Module's firmware version
Service Information
Home Network
Current Network
RSSI
Cellular service provider associated with the module's data account
Current cellular service operator (Not available for C2 or EV3 models)
Received Signal Strength Indication
Service
Roaming
Cellular service connection type
Indicates whether or not the current service is provided by the Home Network carrier
Update Options
MDN (Phone Number) Update the cellular module's phone number. This number is updated only on the device. The MDN that the carrier has associated with this device does not change.
Telit Radio Firmware Upgrade
H5, H6, and LTE only
The update of Telit radio module firmware supports full firmware files and upgrade of H5, H6, and LTE models.
Refer to your product model number on the product label usually found on the bottom or back of your device or also at the top of the page of the device UI.
Note: If you have LoRa capability, you must have it disabled to perform the radio firmware upgrade.
There are two methods for updating the cellular firmware offered: 1) Upgrading using DeviceHQ ® using the device UI only.
and 2) Upgrading
Upgrading Cellular Firmware Using DeviceHQ (Remote Management)
DeviceHQ can manage the Telit Firmware upgrade to your device when annex-client checks in.
NOTE: You must first enable and properly configure Remote Management in the device UI (refer to
mPower TM Edge Intelligence Conduit AEP Software Guide
CELLULAR
1.
Open DeviceHQ .
2.
Select Device > Your Device Name > Schedule > Upgrade Radio Firmware .
3.
DeviceHQ provides a list of eligible Telit module firmware that a particular device can queue for download and install. Select the appropriate firmware.
4.
The device checks in, downloads the firmware, automatically verifies the MD5 sum of the firmware to check the integrity of the upgrade file, and applies it to the modem module.
Note: Allow at least 10 minutes after the device has downloaded the firmware file before taking any action. The system should reboot on its own after a successful download. Otherwise, after 10 minutes, you may reboot the device manually.
5.
Once you have refreshed or the device checks in again, verify that the cellular radio firmware has been updated in DeviceHQ.
In the device UI, you can also check that the cellular radio firmware has been updated. Refer to the Current Radio
Firmware on the Telit Radio Firmware Upgrade page (see step 1 of Upgrading Cellular Firmware Using UI only ) or also see the firmware version on the Radio Status page under Cellular .
Upgrading Cellular Firmware using UI only
You can also use the device UI to upgrade your Telit Firmware. You must first obtain the appropriate binary upgrade file for the cellular radio in your device.
NOTE : If you use the firmware upgrade via Cellular using the UI and you get a timeout failure, first try to boost the signal strength and attempt it again. Otherwise, update via an Ethernet connection or use DeviceHQ .
1.
Open the Telit Radio Firmware Upgrade page on the device. The page is not available through the standard UI. Enter the IP address/URL manually: https://<Device-IP>/upload_radio_firmware (usually your device IP address is the default address unless you changed it).
2.
Find the upgrade zip file in your product page under Downloads on www.multitech.com
. (The file name starts with stream .) Download the zip file from the website and save it on your local computer. Extract the binary upgrade file and MD5 file.
3.
Enter the MD5 Check Sum or hash under File MD5 .
4.
Browse for the file and select it.
5.
Click Start Upgrade . The system should reboot automatically after a successful download. Otherwise, after 10 minutes, you may reboot the device manually.
6.
Check that the cellular radio firmware has been updated. Refer to the Current Radio Firmware on the
Telit Radio Firmware Upgrade page (see step 1 of Upgrading Cellular Firmware Using UI only ) or also see the firmware version on the Radio Status page under Cellular .
mPower TM Edge Intelligence Conduit AEP Software Guide 73
SMS
Chapter 9 – SMS
Configuring SMS
This function is not available if you enable SMS through Cellular > Wake Up On Call . To enable short message service (SMS) via the Web Management interface or API:
1.
From the Web Management interface, go to SMS > SMS Configuration > SMS Settings .
2.
Check Enabled .
3.
In the Sent SMS to Keep field, enter the total number of sent SMS messages to keep in the device's history.
4.
In the Received SMS to Keep field, enter the total number of received SMS messages to keep in the device's history.
5.
In the Resend Failed SMS field, enter the total number of resend attempts for SMS messages that failed to send.
6.
Set messages to keep and resend options.
7.
Click Submit.
8.
To save your changes, click Save and Restart .
For field descriptions see
.
SMS Field Descriptions
Field
Enabled
Sent SMS to Keep
Received SMS to Keep
Resend Failed SMS
Description
Enables the SMS utilities required to send SMS via API and the Web Management interface.
The total number of sent SMS messages to keep in the device's history.
The total number of received SMS messages to keep in the device's history.
The total number of resend attempts for SMS messages that failed to send.
SMS Commands
SMS commands are disabled by default.
First, make sure to enable SMS under SMS > SMS Configuration > SMS Settings .
To enable these available commands (for status and debugging purposes) and set security filters:
1.
Go to SMS > SMS Configuration > SMS Commands , check the SMS commands you wish to enable. Refer to the table of
for details on available commands.
2.
Check the security filters, you wish to use (can be one or both):
Password: If enabled, SMS commands will require p password in the syntax. For example: p
123456 #serial where 123456 is your password.
Use the default password (last six digits of the radio's IMEI or last six digits of the
MEID).
Or click on Use custom password and enter your own password.
You can also toggle the eye icon to make the password visible or hidden.
74 mPower TM Edge Intelligence Conduit AEP Software Guide
SMS
Whitelist : If enabled, SMS commands can only be received from a number in the whitelist (you must enter a phone number).
Enter the phone number and click Add Number .
Note : Due to differences between service providers, for every US number you add to the Whitelist , create two separate entries: 1) one using the phone number and 2) the other using 1 + phone number . Tip: Since the number format varies with provider, you can send your device an SMS message from the number in question and see what format is used.
3.
Refer to the Required SMS Command Format field to see the format based on your chosen settings.
4.
Click Submit .
5.
To save your changes, click Save and Restart .
Here is an example SMS Command (#serial – Server mode):
Serial-IP Port Status:
Mode: Server
Protocol: SSL/TLS
Port: 3000
TX Bytes: 1234567
RX Bytes: 123456789
DCD Status: ON
2016-11-20 19:22
The response message to all SMS commands includes a time stamp. The time stamp format is YYYY-MM-DD
HH:MM .
The system adds the time stamp to the existing commands at the end of the SMS message. In case the message exceeds the 160 character limit, the device information and the occurred event are not truncated. Only the time stamp is lost.
SMS Command Descriptions
The following table describes available SMS Commands under SMS Configuration > SMS Commands > Enabled
Commands . All SMS Commands are disabled by default. Check to enable.
SMS Command
#reboot
#checkin
#rm <enable|disable> <AccountKey>
#setcellular <enable|disable> [<APN>]
Description reboots the device checks in to DeviceHQ enable or disable remote management using DeviceHQ
(You must specify AccountKey when enabling Remote
Management if not previously configured.) enable or disable Cellular and allows setting of the APN mPower TM Edge Intelligence Conduit AEP Software Guide 75
SMS
SMS Command
#ping [<interface>] [<count>] <address>
#apn
#cellular
#radio
#ethernet
#wan
#serial
#wifi
#geoposition
#lnsrestart
Description ping IP address <count> times (range: 1-20, default = 4) through <interface> (choose from cellular, wifi, and ethernet or if not specified, the default gateway interface is used) get APN string
PPP status radio status
Ethernet LAN configuration details
WAN transport type and WAN priority configuration get serial details: Mode (Server or Client), RX bytes, TX bytes, DCD Status, Protocol, Port (Server mode only),
Server IP Address (Client mode only), and Server Port
(Client Mode only) get Wi-Fi details: Date and time in format YYYY-MM-DD
HH:MM, mode (WAN or Access Point), MAC address, status (for WAN mode only), SSID, Security settings (for
Access Point only, None, WEP, WPA, WPA2-PSK, and
WPA/WPA2-PSK)
Upon reception, the device sends back its GPS coordinates, latitude and longitude, as an SMS text message (only available on devices with a GPS module)
Upon reception, the device restarts the LoRa network server
Note: Arguments in square brackets [ ] are optional. Those in angle brackets < > are values.
Sending an SMS Message
To send an SMS message from the device:
1.
Go to SMS > Send SMS to display the Send SMS window.
2.
In the Recipient field, enter a phone number and click Add . You can add up to 100 phone numbers.
3.
In the Message field, enter a text message up to 160 characters long.
4.
Click Send . The system displays a confirmation indicating whether the message has been successfully sent or not.
Viewing Received SMS Messages
To view received SMS messages from the device:
1.
Go to SMS > Received to display the Received SMS window. The messages are sorted by date with the most recent messages on top. The table shows up to 30 characters for each message.
2.
To view the full message, click the eye icon to the right of the message entry.
76 mPower TM Edge Intelligence Conduit AEP Software Guide
SMS
3.
To delete an SMS message, click the trash can icon under Options to the right of the message. A dialog box asks you to confirm that you want to delete the SMS message. Click OK .
4.
To delete all the received SMS messages, click Delete All . A dialog box asks you to confirm that you want to delete all SMS messages. Click OK .
5.
To configure, the receive list to automatically update, check the Auto Refresh box in the upper right corner.
Viewing Sent SMS Messages
To view sent SMS messages from the device:
1.
Go to SMS > Sent to display the Sent SMS window. The messages are sorted by date with the most recent messages on top. The table shows up to 30 characters for each message.
2.
To view a full message, click the eye icon to the right of the message entry.
3.
To delete a sent SMS message, click the trash can icon to the right of the message entry. A dialog box asks you to confirm that you want to delete the SMS message. Click OK .
4.
To delete all the sent SMS messages, click Delete All . A dialog box asks you to confirm that you want to delete all the SMS messages. Click OK .
5.
To configure, the receive list to automatically update, check the Auto Refresh box in the upper right corner.
mPower TM Edge Intelligence Conduit AEP Software Guide 77
TUNNELS
Chapter 10 – Tunnels
Setting Up GRE Tunnels
Tunneling allows the use of a public network to convey data on behalf of two remote private networks. It is also a way to transform data frames to allow them to pass networks with incompatible address spaces or even incompatible protocols. Generic Routing Encapsulation (GRE) is a tunneling mechanism that uses IP as the transport protocol and can be used for carrying many different passenger protocols.
The tunnels behave as virtual point-to-point links that have two endpoints identified by the tunnel source and tunnel destination addresses at each endpoint. Configuring a GRE tunnel involves creating a tunnel interface, which is a logical interface, then configuring the tunnel endpoints for the tunnel interface. To set up GRE tunnels:
1.
From the Web Management interface, go to Tunnels > GRE Tunnels .
2.
Click Add Tunnel .
3.
In the Tunnel Name field, enter a name for the new tunnel.
4.
(Optional) In the Description field, you can enter a description that helps you further identify the tunnel.
5.
In the GRE Tunnel Settings section: a.
In the Remote WAN IP field, type the IP address of the gateway to which you want to connect.
b.
Click Add in the Remote Network Routes table.
c.
In the Remote Network Route field, type the IP address of the network that is routed through the tunnel.
d.
In the Remote Network Mask field, type the mask of the network.
e.
Click Add . The defined Remote Network Route is added and appears in the Network Routes list.
6.
(Optional) In the Checking period (minutes) specify the interval to resolve the Remote WAN hostname by
DynDNS. Recommended for hostnames that have dynamic IP addresses.
7.
Click Submit .
8.
The defined GRE tunnel configuration is added and appears in the GRE Tunnels list .
9.
To save your changes, click Save and Restart .
Configuring Network-to-Network Virtual Private Networks (VPNs)
IPsec Tunnels
The device supports site-to-site VPNs via IPsec tunnels for secure network-to-network communication. Both tunnel endpoints should have static public IP addresses and must be able to agree on the encryption and authentication methods to use. Setting up an IPsec tunnel is a two-stage negotiation process. The first stage negotiates how the key exchange is protected. The second stage negotiates how the data passing through the tunnel is protected. For endpoints that do not have public static IP addresses, additional options may help such as NAT Traversal and
Aggressive Mode .
By default, based on the encryption method chosen, the device negotiates ISAKMP hash and group policies from a default set of secure algorithms with no known vulnerabilities. This allows flexibility in establishing connections with remote endpoints. There is an ADVANCED mode that provides a way to specify a strict set of algorithms to use per phase, limiting the remote endpoint's negotiation options.
The default set of Hash Algorithms is: SHA-1, SHA-2 , and MD5 .
78 mPower TM Edge Intelligence Conduit AEP Software Guide
TUNNELS
The default set of DH Group Algorithms is: DH2(1024-bit), DH5(1536-bit), DH14(2048-bit), DH15(3072-bit),
DH16(4096-bit), DH17(6144-bit), DH18(8192-bit), DH22(1024-bit), DH23(2048-bit) , and DH24(2048-bit) .
To set up a Network-to-Network VPN tunnel on your device:
1.
From the Web Management interface, go to Tunnels > IPsec Tunnels .
2.
Click Add Tunnel in upper right.
3.
Enter a Name for the tunnel and an optional Description .
4.
Click Next . The IPsec Remote Tunnel Endpoint pane opens.
5.
Enter a network manually by entering the Remote Network Route (LAN IP) and Remote Network Mask
(Subnet).
6.
Choose Tunnel Type from the drop-down. Values are IKE and IKEv2 .
7.
The public IP address and LAN of this device do not need to be configured because they are already known by this device.
8.
Select the Authentication Method from the drop-down either Pre-Shared Key or RSA Signatures .
Authentication is performed using secret pre-shared keys and hashing algorithms (like SHA1 MD5 ) or RSA signatures.
9.
If you select Pre-Shared Key , then enter the Secret . This key needs to be the same on both endpoints.
10.
If you select RSA Signatures , enter the following (in .pem format): a.
CA Certificate b.
Local RSA Certificate c.
Local RSA Private Key
11.
Select the Encryption Method from the drop-down including 3DES, AES-128, AES-192, AES-256 , or
ADVANCED . The encryption method needs to be the same on both endpoints. IKE encryption algorithm is used for the connection ( phase 1 - ISAKMP SA) . Based off of phase 1 , a secure set of defaults are used for phase 2 , unless you use the Advanced option, in which case, you must specify all components of both phases 1 and 2 including Encryption , Authentication , and Key Group .
12.
If the remote endpoint is set up with unique IDs, check the Enable UID box, and enter the Local and
Remote IDs .
13.
Click Show for IPSec Tunnel: Advanced features that limit the remote endpoint's negotiation options.
14.
In the IKE Lifetime field, enter the duration in which ISAKMP SA lasts (in hours).
15.
In the Max Retries field, enter the number of retries for the IPSec Tunnel. Enter zero for unlimited retries.
16.
In the Key Life field, duration in which the IPSec SA lasts (in hours).
17.
In the Checking Period field, enter the timeout interval (in minutes).
18.
Check Compression to enable IPComp (compression algorithm).
19.
Check Aggressive Mode to enable exchange identification in plain text (unencrypted for faster negotiation). NOTE: This mode is less secure and prone to dictionary and brute force attacks.
20.
Click Submit .
21.
To save your changes, click Save and Restart .
For field descriptions, see
IPsec Tunnel Configuration Field Descriptions
.
mPower TM Edge Intelligence Conduit AEP Software Guide 79
TUNNELS
IPsec Tunnel Configuration Field Descriptions
Field
IPSec Tunnel
Name
Description
Description
Name used to identify the IPsec tunnel in configurations and logs.
Optional text to describe the IPsec tunnel. This description shows up in the UI while hovering over the summary of an IPsec tunnel.
IPSec Remote Tunnel Endpoint
Remote WAN IP
Remote Network Route
Remote Network Mask
Tunnel Type
External IP address of the remote tunnel endpoint. The remote device is typically a router.
This field is used in conjunction with the Remote Network Mask field and describes the remote endpoint's subnet. This is used to identify packets that are routed over the tunnel to the remote network.
This field is used in conjunction with the Remote Network Route field, to describe the remote endpoint's subnet. It identifies packets that are routed over the tunnel to the remote network.
Internet Key Exchange (IKE) for host-to-host, host-to-subnet, or subnetto-subnet tunnels. Choose from IKE or IKEv2 .
IPsec Tunnel: IKE
Authentication Method
Pre-Shared Key
Secret
Encryption Method
RSA Signatures
CA Certificate
Local RSA Certificate
Local RSA Private Key
Choose between Pre-Shared Key or RSA Signatures . Authentication is performed using secret pre-shared keys and hashing algorithms (like
SHA1 MD5) or RSA signatures (you provide the CA Certificate, Local RSA
Certificate , and Local RSA Private Key in .pem format). If you check
Enable UID , then Local ID and Remote ID become available as options.
Authentication is performed using a secret pre-shared key and hashing algorithms on both sides.
Secret key that is known by both endpoints.
IKE encryption algorithm used for the connection (phase 1 - ISAKMP SA).
Based off of phase 1, a secure set of defaults are used for phase 2, unless the Advanced option is used, in which case, all components of both phases 1 and 2 are specified by the user.
Authentication is performed using digital RSA signatures.
Certificate Authority certificate used to verify the remote endpoint's certificate.
Certificate the local endpoint uses during Phase 1 Authentication .
The private key that the local endpoint uses during Phase 1
Authentication.
80 mPower TM Edge Intelligence Conduit AEP Software Guide
Phase 1 Encryption
Phase 1 Authentication
Phase 1 Key Group
Phase 2 Encryption
Phase 2 Authentication
Phase 2 Key Group
Enable UID
Local ID
Remote ID
IPSec Tunnel: Advanced
IKE Lifetime
Key Life
Max Retries
Checking Period
Field
Encryption Method
TUNNELS
Description
Choose an Encryption Method from the following list: 3DES, AES-128,
AES-192, AES-256, or ADVANCED . IKE encryption algorithm is used for the connection (phase 1 - ISAKMP SA). Based off of phase 1, a secure set of defaults are used for phase 2, unless the Advanced option is used, in which case, all components of both phases 1 and 2 are specified by the user.
If Advanced is selected for Encryption Method , select Phase 1
Encryption from the drop-drown: 3DES, AES-128, AES-192, AES-256,
ANY AES , or ANY .
If Advanced is selected for Encryption Method , select Phase 1
Authentication from the drop-drown: MD5, SHA-1, SHA-2, SHA2-256,
SHA2-384, SHA2-512 , or ANY .
If Advanced is selected for Encryption Method , select the Phase 1 Key
Group from the drop-down: DH2 (1024-bit), DH5 (1536-bit), D14 (2048bit), DH15 (3072-bit), DH16 (4096-bit), DH17 (6144-bit), DH18 (8192bit), DH22 (1024-bit), DH23 (2048-bit), DH24 (2048-bit), and ANY .
If Advanced is selected for Encryption Method , select Phase 2
Encryption from the drop-drown: 3DES, AES-128, AES-192, AES-256,
ANY AES, or ANY .
If Advanced is selected for Encryption Method , select Phase 2
Authentication from the drop-drown: MD5, SHA-1, SHA-2, SHA2-256,
SHA2-384, SHA2-512, or ANY .
If Advanced is selected for Encryption Method , select the Phase 2 Key
Group from the drop-down: DH2 (1024-bit), DH5 (1536-bit), D14 (2048bit), DH15 (3072-bit), DH16 (4096-bit), DH17 (6144-bit), DH18 (8192bit), DH22 (1024-bit), DH23 (2048-bit), DH24 (2048-bit), and ANY .
Unique Identifier String to enable the Local ID and Remote ID fields.
String Identifier for the local security gateway (optional)
String Identifier for the remote security gateway (optional)
Duration for which the ISAKMP SA exists from successful negotiation to expiration.
Duration for which the IPsec SA exists from successful negotiation to expiration.
Number of retry attempts for establishing the IPsec tunnel. Enter zero for unlimited retries.
Timeout interval in minutes. If Remote WAN IP address is a hostname that can be resolved by DynDNS, the hostname will be resolved at the set interval. Recommended for dynamic IP addresses.
mPower TM Edge Intelligence Conduit AEP Software Guide 81
TUNNELS
82
Field
Compression
Aggressive Mode
Description
Enable IPComp. This protocol increases the overall communication performance by compressing the datagrams. Compression requires greater CPU processing.
Whether to allow a less secure mode that exchanges identification in plain text. This may be used for establishing tunnels where one or more endpoints have a dynamic public IP address. Although this mode is faster to negotiate phase 1, the authentication hash is transmitted unencrypted. You can capture the hash and start a dictionary or use brute force attacks to recover the PSK.
OpenVPN Tunnels
OpenVPN is an open-source software application that implements virtual private network (VPN) techniques for creating secure point-to-point or site-to-site connections in routed or bridged configurations and remote access facilities. You can use and setup OpenVPN tunnels with this device.
To use OpenVPN, you must first install an OpenVPN application along with an easy-rsa tool and configure OpenVPN on your computer. Then you must also generate the certificates for the OpenVPN server and client before configuring the device.
To configure OpenVPN client and server on this device the following files are required:
The CA PEM file or CA certificate (.crt)
The Diffie Hellman PEM file (.pem)
The Server Certificate to be used by the device endpoint (.crt)
The Server/Client Key to be used by the device endpoint (.key)
Note: When you configure OpenVPN server and client make sure both sides use the same settings, and certificates.
Configuration 1: OpenVPN Tunnel with TLS Authorization Mode (Device only)
This first configuration establishes the OpenVPN Tunnel connection from a device client to a device server using
TLS as Authorization Mode. This involves adding and configuring both OpenVPN Server and Client sides within the device UI.
To add an OpenVPN Server using TLS :
1.
Go to Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration .
2.
Click Add Tunnel .
3.
Enter the Name .
4.
Select the Type as SERVER from the drop-down.
5.
You can also enter an optional Description .
6.
Under OpenVPN Tunnel Configuration, enter the following fields (using TLS as Authorization Mode ): a.
Interface Type as TUN from the drop-down.
b.
Authorization Mode as TLS from the drop-down.
c.
Protocol as UDP .
d.
VPN Subnet .
mPower TM Edge Intelligence Conduit AEP Software Guide
TUNNELS e.
Port number.
f.
VPN Netmask .
g.
LZO Compression as ADAPTIVE from the drop-down.
h.
Hash Algorithm as DEFAULT .
i.
Encryption Cipher as DEFAULT .
j.
Min. TLS Version as 1.2
.
k.
TLS Cipher Suite as DEFAULT as 1.2
.
l.
Enter the contents of the following files generated from the easy-rsa tool. You can copy and paste this content from the certificate files after opening from a text editor like Notepad. (all required): i.
CA PEM (.crt) ii.
Diffie Hellman PEM (.pem) iii.
Server Certificate PEM (.crt) iv.
Server Key PEM (.key)
Note: Use the same CA PEM certificate and parameters as the server for the OpenVPN clients .
7.
Remote Network Routes create a route from the server network to the client network. This allows the server to get access to the client’s network. In the OpenVPN Tunnel Network Routes , click Add : a.
Enter the Remote Network Route (should be the client subnet). For example, if the client IP address is 192.168.3.1, enter 192.168.3.0.
b.
Enter the Remote Network Mask (usually 255.255.255.0).
c.
You may enter Gateway (optional).
d.
Click Add .
8.
The system displays your recently-added Push Route with the client subnet (remote network route + mask).
9.
Push Routes create a route from client’s network to the server’s network. This allows clients to get access to the server’s network. Under Push Routes : a.
Click Client To Client box if you want this optional feature (this establishes a connection between multiple clients that are connected to the server).
b.
In the Push Network Route , click Add .
c.
In the dialog box, enter the Remote Network Route (same address as the server subnet above).
d.
Enter the Remote Network Mask (same as above).
e.
You may enter Gateway (optional).
f.
Click Add .
Note: If you use Static Key Authorization Mode , the Push Routes do not work.
10.
The system displays your recently-added Push Route with the client subnet (remote network route + mask).
11.
Click Preview to view the tunnel configuration.
12.
Click Submit .
13.
Click Save and Restart to save your changes
To add an OpenVPN Client using TLS : mPower TM Edge Intelligence Conduit AEP Software Guide 83
TUNNELS
1.
Go to Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration .
2.
Click Add Tunnel .
3.
Enter the Name of the tunnel.
4.
Select the Type as CLIENT from the drop-down.
5.
You can also enter an optional Description .
6.
Under OpenVPN Tunnel Configuration, enter the following fields (using TLS as Authorization Mode ): a.
Interface Type as TUN from the drop-down.
b.
Authorization Mode as TLS from the drop-down.
c.
Protocol as UDP .
d.
Remote Host (server public IP address).
e.
Remote Port number.
f.
LZO Compression as ADAPTIVE from the drop-down.
g.
Hash Algorithm as DEFAULT .
h.
Encryption Cipher as DEFAULT.
i.
Min. TLS Version as 1.2.
j.
TLS Cipher Suite as DEFAULT .
k.
Enter the contents of the following files generated from the easy-rsa tool. You can copy and paste this content from the certificate files after opening from a text editor like Notepad. (all required): i.
CA PEM (.crt) ii.
Client Certificate PEM (.crt) iii.
Client Key PEM (.key)
7.
If you use TLS as Authorization Mode , you do not need configure or add Remote Network Routes . The server adds the routes if the server's Push Routes are already configured. If you use Static Key as
Authorization Mode , you must add and configure Remote Network Routes .
8.
Click Preview to view the tunnel configuration.
9.
Click Submit .
10.
Click Save and Restart to save your changes.
Now the device client can access the device server subnet. You can ping the IP address of the device server subnet from the client console to test this.
Note: The PC connected to the device does not have access to the device server subnet.
Configuration 2: OpenVPN Tunnel with TLS Authorization Mode (Device and Connected PC)
This second configuration provides access between a device server and its subnet and device client and its subnet.
An additional configuration is needed on the device server side. This also allows your PC to connect with the device server and ultimately to the device client through that server.
1.
Configure the device server as shown under how to add an OpenVPN Server using TLS .
2.
Open device console, go to /var/config/ovpnccd/openVPNServerName . Create the folder if not present in the device.
3.
Create a file that has the client certificate name with the following information: a.
iroute [Client_Subnet] [Mask ]
84 mPower TM Edge Intelligence Conduit AEP Software Guide
TUNNELS b.
example -- echo “iroute 192.168.3.0 255.255.255.0” > mtrClient1
4.
For each client, you must create a separate file in the folder /var/config/ovpnccd/yourserverName .
Note: Make the file name the same as the Common Name value used to create the certificate.
5.
Configure device client as shown under how to add an OpenVPN Client .
Once properly configured, you should have a connection between the device server and device client and their subnets. Your PC can also connect with the device server and thus the device client through that server.
Configuration 3: OpenVPN Tunnel with Static Key Authorization Mode (device server and client)
This third configuration establishes the OpenVPN Tunnel connection from a device client to a device server using
Static Key as Authorization Mode. This involves adding and configuring both OpenVPN Server and Client sides within the device UI.
When using Static Key, the OpenVPN tunnel is created between only two end-points, the client and server. You cannot connect more than one client to the server in this mode. Remote Network Route must be specified in both configurations, client and server, in order to establish the connection between subnets.
To add an OpenVPN Server using Static Key :
1.
Go to Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration .
2.
Click Add Tunnel .
3.
Enter the Name .
4.
Select the Type as SERVER from the drop-down.
5.
You can also enter an optional Description .
6.
Enter the following fields (using STATIC KEY as Authorization Mode ): a.
Interface Type as TUN from the drop-down.
b.
Authorization Mode as STATIC KEY from the drop-down.
c.
Protocol as UDP .
d.
Local Address as DEFAULT .
e.
Port number.
f.
Remote Address as DEFAULT .
g.
LZO Compression as ADAPTIVE from the drop-down.
h.
Hash Algorithm as DEFAULT .
i.
Encryption Cipher as DEFAULT .
j.
Generate and enter the Static Key PEM (required). Both server and client must use the same static key. See example below:
-----BEGIN OpenVPN Static key V1-----
3f4c9113b2ec15a421cfe21a5af015bb967059021c1fd6f66ecfd00533d967237875215e20e80a2d59efd
79148d6acdea9358dcafe0efdbb54003ff376c71432dd9d16f55e7d8917a32bfe07d61591b7bbb43c7ba d214482b8547ec9dca8910f514d9f4270ccaeff1a79852ae27c1c307c9dc3c836d1c380bece3c70fd2104 e1968ed29b6c3388719226f959f69f9be43688ed27bc3a4dbc83f640370524b47bb871816af79586d07
08781fad384480d0609b11c31d27baa6e902d29277a474e3e2785a8410d595c0f9c75312375b4bd098
76e1a47a598e114749a09c35f098e9123015c2795c702e4a346a8bccd00305c7cb30beef66ad33f43dac c2e662128
-----END OpenVPN Static key V1----mPower TM Edge Intelligence Conduit AEP Software Guide 85
TUNNELS
7.
Remote Network Routes create a route from the server network to the client network. This allows the server to get access to the client’s network. In the OpenVPN Tunnel Network Routes , click Add : a.
Enter the Remote Network Route (should be the client subnet). For example, if the client IP address is 192.168.3.1, enter 192.168.3.0.
b.
Enter the Remote Network Mask (usually 255.255.255.0).
c.
Click Add .
8.
The system displays your recently-added Remote Network Route with the client subnet (remote network route + mask).
Note: Push Routes are not required with Static Key as Authorization Mode.
9.
Click Preview to view the tunnel configuration.
10.
Click Submit .
11.
Click Save and Restart to save your changes.
To add an OpenVPN Client using Static Key :
1.
Go to Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration .
2.
Click Add Tunnel .
3.
Enter the Name .
4.
Select the Type as CLIENT from the drop-down.
5.
You can also enter an optional Description .
6.
Enter the following fields (using STATIC KEY as Authorization Mode ): a.
Interface Type as TUN from the drop-down.
b.
Authorization Mode as STATIC KEY from the drop-down.
c.
Protocol as UDP .
d.
Local Address as DEFAULT .
e.
Remote Host .
f.
Remote Address as DEFAULT .
g.
Remote Port number.
h.
LZO Compression as ADAPTIVE from the drop-down.
i.
Select the Encryption Cipher as DEFAULT from drop-down.
j.
Select the Hash Algorithm as DEFAULT from drop-down.
k.
Min. TLS Version as 1.2.
l.
TLS Cipher Suite as DEFAULT .
m.
Enter the Static Key PEM (required). Both server and client must use the same static key. See example below:
-----BEGIN OpenVPN Static key V1-----
3f4c9113b2ec15a421cfe21a5af015bb967059021c1fd6f66ecfd00533d967237875215e20e80a2d59efd
79148d6acdea9358dcafe0efdbb54003ff376c71432dd9d16f55e7d8917a32bfe07d61591b7bbb43c7ba d214482b8547ec9dca8910f514d9f4270ccaeff1a79852ae27c1c307c9dc3c836d1c380bece3c70fd2104 e1968ed29b6c3388719226f959f69f9be43688ed27bc3a4dbc83f640370524b47bb871816af79586d07
08781fad384480d0609b11c31d27baa6e902d29277a474e3e2785a8410d595c0f9c75312375b4bd098
76e1a47a598e114749a09c35f098e9123015c2795c702e4a346a8bccd00305c7cb30beef66ad33f43dac c2e662128
86 mPower TM Edge Intelligence Conduit AEP Software Guide
TUNNELS
-----END OpenVPN Static key V1-----.
7.
Remote Network Routes create a route from the server network to the client network. This allows the server to get access to the client’s network. In the OpenVPN Tunnel Network Routes , click Add : a.
Enter the Remote Network Route (should be the client subnet). For example, if the client IP address is 192.168.3.1, enter 192.168.3.0.
b.
Enter the Remote Network Mask (usually 255.255.255.0).
c.
Click Add .
8.
The system displays your recently-added Remote Network Route with the client subnet (remote network route + mask).
Note: Push Routes are not required with Static Key as Authorization Mode.
9.
Click Preview to view the tunnel configuration.
10.
Click Submit .
11.
Click Save and Restart to save your changes.
Configuration 4: OpenVPN Tunnel with Static Key Authorization Mode and TCP
This fourth configuration establishes the OpenVPN Tunnel connection from a device client to a device server using
Static Key as Authorization Mode and TCP protocol (instead of UDP for the third configuration). This involves adding and configuring both OpenVPN Server and Client sides within the device UI.
To add an OpenVPN Server using Static Key and TCP :
1.
Go to Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration .
2.
Click Add Tunnel .
3.
Enter the Name .
4.
Select the Type as SERVER from the drop-down.
5.
You can also enter an optional Description .
6.
Enter the following fields (using STATIC KEY as Authorization Mode ): a.
Interface Type as TUN from the drop-down.
b.
Authorization Mode as STATIC KEY from the drop-down.
c.
Protocol as TCP .
d.
Local Address as DEFAULT .
e.
Port number.
f.
Remote Address as DEFAULT .
g.
Hash Algorithm as ECDSA-WITH-SHA1 .
h.
LZO Compression as ADAPTIVE from the drop-down.
i.
Encryption Cipher as CAMELLIA-256-CBC .
j.
Min. TLS Version as NONE.
k.
TLS Cipher Suite as DEFAULT .
l.
Generate and enter the Static Key PEM (required). Both server and client must use the same static key. See example below:
-----BEGIN OpenVPN Static key V1-----
3f4c9113b2ec15a421cfe21a5af015bb967059021c1fd6f66ecfd00533d967237875215e20e80a2d59efd
79148d6acdea9358dcafe0efdbb54003ff376c71432dd9d16f55e7d8917a32bfe07d61591b7bbb43c7ba mPower TM Edge Intelligence Conduit AEP Software Guide 87
TUNNELS
88 d214482b8547ec9dca8910f514d9f4270ccaeff1a79852ae27c1c307c9dc3c836d1c380bece3c70fd2104 e1968ed29b6c3388719226f959f69f9be43688ed27bc3a4dbc83f640370524b47bb871816af79586d07
08781fad384480d0609b11c31d27baa6e902d29277a474e3e2785a8410d595c0f9c75312375b4bd098
76e1a47a598e114749a09c35f098e9123015c2795c702e4a346a8bccd00305c7cb30beef66ad33f43dac c2e662128
-----END OpenVPN Static key V1-----
7.
Click Next .
8.
Remote Network Routes create a route from the server network to the client network. This allows the server to get access to the client’s network. In the OpenVPN Tunnel Network Routes , click Add : a.
Enter the Remote Network Route (should be the client subnet). For example, if the client IP address is 192.168.3.1, enter 192.168.3.0.
b.
Enter the Remote Network Mask (usually 255.255.255.0).
c.
Click Add .
9.
The system displays your recently-added Remote Network Route with the client subnet (remote network route + mask).
Note: Push Routes are not required with Static Key as Authorization Mode.
10.
Click Preview to view the tunnel configuration.
11.
Click Submit .
12.
Click Save and Restart to save your changes.
To add an OpenVPN Client using Static Key and TCP :
1.
Go to Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration .
2.
Click Add Tunnel .
3.
Enter the Name .
4.
Select the Type as CLIENT from the drop-down.
5.
You can also enter an optional Description .
6.
Enter the following fields (using STATIC KEY as Authorization Mode ): a.
Interface Type as TUN from the drop-down.
b.
Authorization Mode as STATIC KEY from the drop-down.
c.
Protocol as TCP .
d.
Local Address as DEFAULT .
e.
Remote Host .
f.
Remote Address as DEFAULT .
g.
Remote Port number.
h.
Hash Algorithm as ECDSA-WITH-SHA1 .
i.
LZO Compression as ADAPTIVE from the drop-down.
j.
Encryption Cipher as CAMELLIA-256-CBC .
k.
Min. TLS Version as NONE.
l.
TLS Cipher Suite as DEFAULT .
m.
Generate and enter the Static Key PEM (required). Both server and client must use the same static key. See example below:
-----BEGIN OpenVPN Static key V1----mPower TM Edge Intelligence Conduit AEP Software Guide
TUNNELS
3f4c9113b2ec15a421cfe21a5af015bb967059021c1fd6f66ecfd00533d967237875215e20e80a2d59efd
79148d6acdea9358dcafe0efdbb54003ff376c71432dd9d16f55e7d8917a32bfe07d61591b7bbb43c7ba d214482b8547ec9dca8910f514d9f4270ccaeff1a79852ae27c1c307c9dc3c836d1c380bece3c70fd2104 e1968ed29b6c3388719226f959f69f9be43688ed27bc3a4dbc83f640370524b47bb871816af79586d07
08781fad384480d0609b11c31d27baa6e902d29277a474e3e2785a8410d595c0f9c75312375b4bd098
76e1a47a598e114749a09c35f098e9123015c2795c702e4a346a8bccd00305c7cb30beef66ad33f43dac c2e662128
-----END OpenVPN Static key V1-----
7.
Click Next .
8.
Remote Network Routes create a route from the server network to the client network. This allows the server to get access to the client’s network. In the OpenVPN Tunnel Network Routes , click Add : a.
Enter the Remote Network Route (should be the client subnet). For example, if the client IP address is 192.168.3.1, enter 192.168.3.0.
b.
Enter the Remote Network Mask (usually 255.255.255.0).
c.
Click Add .
9.
The system displays your recently-added Remote Network Route with the client subnet (remote network route + mask).
Note: Push Routes are not required with Static Key as Authorization Mode.
10.
Click Preview to view the tunnel configuration.
11.
Click Submit .
12.
Click Save and Restart to save your changes.
mPower TM Edge Intelligence Conduit AEP Software Guide 89
ADMINISTRATION
Chapter 11 – Administration
User Accounts
Use this feature to add user accounts or change the password.
The system offers three roles or user types: administrator, engineer, and monitor. Administrators have full rights and permissions including change settings on the device. Engineers have read/write privileges and some access to controls on the device. Monitors have read-only access. Note: the system automatically checks for a strong password and tells you how to improve it.
Username requirements include:
Must be unique.
Is case-sensitive (for example, admin and ADMIN are treated as two different usernames).
Acceptable characters: uppercase alphabetic, lowercase alphabetic, numeric, and non-alphanumeric
(symbols like #).
A hyphen (-) should not be used as the first character.
Password requirements include:
User account is disabled if password is not set up.
Must be at least eight characters in length.
Contains three or more different types of characters such as: uppercase alphabetic, lowercase alphabetic, numeric, and non-alphanumeric (symbols like #).
Administrator details:
Able to delete any local users. (Engineer and Monitor cannot delete any users.)
Able to modify any other user details, except username.
Can not modify another administrator user account if it is the only enabled local administrator user on the device.
Able to modify own account details except Role, Username, and Enabled values.
Able to disable and enable any local users except their own account. Also, not able to disable local user account if this is only local administrator.
Able to change own password and other user passwords.
Engineer and Monitor details:
Able to view and modify own user account details except Role, Username, and Enabled values.
Access to only their own user account.
Not able to delete users.
Able to change own password.
To add new users:
1.
Go to Administration > User Accounts .
2.
Click Add New User .
3.
Under User Details , enter the following fields:
90 mPower TM Edge Intelligence Conduit AEP Software Guide
ADMINISTRATION a.
Username (required) b.
Role (required). Select the user role from the drop-down menu including administrator , engineer , or monitor .
c.
First Name d.
Last Name e.
Title f.
Division g.
Employee Identification
4.
Under Contact Information , enter the following fields: a.
Email b.
Address c.
City d.
State e.
Country f.
Postal Code g.
Work Phone h.
Mobile Phone
5.
Click Submit .
6.
The Change Password page opens. Enter New Password . Click Submit .
7.
The Change Password page opens. Enter New Password . Click Submit .
If the password is not set up for the new user, the user is disabled until the password is set.
Password Complexity
Password Complexity Rules allow an administrative user to choose rules and limitations on user passwords. You can determine various password parameters such as the minimum length of passwords, upper and lower case requirements, and characters not permitted.
Before choosing your options, you must first select between two different complexity modes: Default or Credit .
Default mode uses a minimum character length and may require a specific number of characters from each class.
But requiring specific classes of characters actually makes brute force attacks easier because it reduces the search space.
For this reason, we recommend using Credit mode. This mode grants one credit per password character plus one extra credit for certain character classes up to their respective extra credit cap. You can still specify a minimum number of classes, but the strongest passwords come from their length.
In either mode, you should use longer passwords for increased security.
1.
Go to Administration > User Accounts .
2.
Click Change Password Complexity Rules button.
3.
Under the Change Password Complexity Rules window, select from the drop-down between Default or
Credit mode.
4.
For Default mode , you may enter the following: mPower TM Edge Intelligence Conduit AEP Software Guide 91
ADMINISTRATION
92 a.
Minimum Password Length (default = 8) b.
Minimum Upper Case Characters (default = 0) c.
Minimum Lower Case Characters (default = 0) d.
Minimum Numeric Characters (default = 0) e.
Minimum Special Characters (default = 0) f.
Maximum Password Length (default = 64)* g.
Characters Not Permitted (enter restricted characters in any order with no separators)
5.
For Credit mode , you may enter the following: a.
Minimum Password Credits (default = 8) b.
Minimum Character Classes (default = 3) c.
Upper Case Extra Credit Cap (default = 0) d.
Lower Case Extra Credit Cap (default = 0) e.
Numeral Extra Credit Cap (default = 0) f.
Special Extra Credit Cap (default = 0) g.
Maximum Password Length in number of characters (default = 64)* h.
Characters Not Permitted (enter restricted characters in any order with no separators)
* Note: Entering a value of 0 indicates no maximum.
Self-Diagnostics
The device offers self-diagnostics or periodic monitoring of certain issues such as memory errors or leaks, and security violations by applications. The following self-diagnostic features are available with this device (varies with model) :
Security Violation
Resource Overuse
This monitoring is intended detect corruption, or help prevent malicious activity. After an event is detected, the system disables the cellular radio module, sends an alarm or notification, logs the event, and sends a record of it via SMS, Email, or to the SNMP server. To receive notifications for specific diagnostic features, configure them under Administration > Notifications .
For the self-diagnostic features, go to Administration > Self-Diagnostics and refer to the following sections.
To turn on the Resource Overuse diagnostic that detects memory leaks or errors:
1.
Check Enabled under Resource Overuse .
2.
If you want the system to reboot the device after a Resource Overuse is detected, check Reboot the device under Actions.
To turn on the Security Violation diagnostic that detects security rule violations by applications:
1.
Check Enabled under Security Violation .
2.
If you want the system to disable WAN interfaces after a Security Violation is detected, check Disable
WAN Interfaces under Actions .
3.
If you want the system to disable user-defined firewall rules after a Security Violation is detected, check
Disable User-Defined Firewall Rules under Actions .
mPower TM Edge Intelligence Conduit AEP Software Guide
ADMINISTRATION
After you completed your Self-Diagnostic configuration (selecting any or all of the above):
1.
Click Submit .
2.
To save changes, click Save and Restart .
If at any time you want to return the device to the default setting, click the Reset to Default button in the bottom right corner. (This disables or removes all enabled Self-Diagnostic features.)
Configuring Device Access
This section contains configurations that determine how the device can be accessed as well as security features that decrease susceptibility to malicious activity.
To display the Access Configuration window containing the fields described below, go to Administration > Access
Configuration .
HTTP Redirect to HTTPS
The device allows only secure access to its Web UI. This set of rules automatically redirects HTTP requests to the device's secure HTTPS port.
Field
Enabled
Port
Via LAN/Ethernet
Via WAN/Cellular
Description
Enables HTTP to HTTPS redirect which automatically redirects users trying to access the device via HTTP to
HTTPS.
The port on which the device listens for HTTP requests to redirect.
If checked, the device listens and redirects HTTP requests to HTTPS from the LAN.
If checked, the device listens and redirects HTTP requests to HTTPS from the WAN.
HTTPS
The device provides secure Web UI access to modify its configurations and execute actions.
Field Description
Port
Via WAN/Cellular
Session Timeout ( under Authorization)
The port on which the device will listen for HTTPS requests.
If checked, the device will listen and respond to HTTPS requests from the WAN. This increases susceptibility to malicious activity.
Amount of time a user's session can remain dormant before automatically being logged out (minutes).
HTTPS Security
Configure the HTTPS security settings (like version and cipher suite). Click the Show link to the right under HTTPS
Security . To enable the Web server to authenticate the client via the client’s public key certificate, check Client
Authentication under the Authentication section.
mPower TM Edge Intelligence Conduit AEP Software Guide 93
ADMINISTRATION
Note: Enabling Client Authentication can prevent users from accessing the Web UI. When Client Authentication is enabled it is required that a web browser has a valid client certificate that is signed by a CA that the server can verify. The CA certificate needs to be uploaded to the device using the upload feature at Administration > X.509
CA Certificates . Configure TLS version and cipher suites under the TLS Settings section.
Description Field
Authentication
Client Authentication Requires web browsers to have a valid client certificate that is signed by a Certifying Authority (CA) that the server can verify. Otherwise, user access to the UI is blocked.
NOTE: You must first upload a CA certificate at
Administration > X.509 CA Certificates.
TLS Settings
Use default cipher suite
TLS 1.2 or TLS 1.1
Cipher Suite Name
Enables use of the default cipher (check by default). No other user input is required.
Check which version of the TLS protocol you want to use: TLS 1.2 or TLS 1.1. Default: TLS 1.2 ( Use default cipher suite must be unchecked.)
Check your preferred Cipher Suite from the following list: ECDHE-RSA-AES256-GCM-SHA384,ECDHE-RSA-
AES256-SHA, DHE-RSA-AES256-GCM-SHA384, AES256-
SHA, ECDHE-RSA-AES128-GCM-SHA256,ECDHE-RSA-
AES128-SHA, DHE-RSA-AES128-GCM-SHA256, DHE-
RSA-AES128-SHA, and/or AES128-SHA . Default:
AES128-SHA ( Use default cipher suite must be unchecked.)
SSH
The device's internal system can be accessed securely via SSH. This is intended for advanced troubleshooting and/or custom deployment solutions.
Field
Enabled
Port
Via LAN/Ethernet
Via WAN/Cellular
Description
Enables SSH redirect which automatically redirects users trying to access the device via SSH (disabled by default).
The port on which the device listens for SSH requests.
If checked, the device listens and responds to SSH requests from the LAN.
If checked, the device listens and respond to SSH requests from the WAN.
Reverse SSH Tunnel
Enable and configure a reverse SSH tunnel.
94 mPower TM Edge Intelligence Conduit AEP Software Guide
ADMINISTRATION
Field
Enabled
Server
Remote Port
Username
Authentication Method
Password
Public Key
Private Key
Description
Enable Reverse SSH tunnel to get SSH access to the device with a public IP address.
Remote SSH server IP address or hostname to which the reverse SSH tunnel connection is established.
Tunnel remote port that opens on the remote end of the reverse SSH tunnel connection (2222 by default).
Remote SSH server username.
Defines Authentication method to use for Reverse SSH
Tunnel . Select from drop-down including Password ,
Public Key , or Private Key .
User’s password on the remote SSH server (when you select Password for Authentication Method).
The public key that the Remote SSH server uses to authorize your device and establish the tunnel connection (when you select Public Key for
Authentication Method).
The private key provided by the remote SSH server
(when you select Private Key for Authentication
Method).
SSH Security
Configure the SSH security settings (like ciphers and HMAC). Click Show to the right under Security Settings . Must select SSL/TLS under Protocol .
Field
Use default cipher suite
Ciphers
HMAC
Description
Enables use of the default cipher (check by default). No other user input is required.
Check which Cipher you want to use: AES128-CTR or
AES256-CTR (Use default cipher suite must be unchecked).
Check which hash-based message authentication code, you want to use: SHA1, SHA2-256,and/or SHA2-512
(Use default cipher suite must be unchecked).
ICMP
Internet Control Message Protocol (ICMP) is used by devices to send error messages such as that a requested service is not available or a host or device could not be reached. ICMP can also relay query messages.
Field
Enabled
Respond to LAN/Via Ethernet
Description
Enables ICMP responses.
If checked, the device will respond to ICMP traffic from the LAN, such as ping requests.
mPower TM Edge Intelligence Conduit AEP Software Guide 95
ADMINISTRATION
Field
Respond to WAN/Via Cellular
Description
If checked, the device will respond to ICMP traffic from the WAN, such as ping requests. This increases susceptibility to malicious activity.
SNMP
The device offers Simple Network Management Protocol (SNMP) which is used for collecting information from, and configuring network devices on an IP network. For more details, refer to Configuring SNMP .
Field
Via LAN
Via WAN
Description
Allows SNMP connections via LAN
Allows SNMP connections via WAN.
Modbus Slave
The Modbus feature allows the user to enable the Modbus query server. You can query this server over Modbus-
TCP for status information.
Field
Enabled (under Modbus Slave )
Via LAN
Port
Description
Enables the Modbus Query Server.
If checked, the device can query the Modbus server via
LAN.
Port number configured for Modbus.
For Modbus query information, refer to the MTR Modbus Information page on our Developer Resources website
(on .net) for details: http://www.multitech.net/developer/software/mtr-software/mtr-modbus-information/
IP Defense
A set of rules that decreases susceptibility to malicious activity. If these settings are configured too strictly, they may interfere with non-malicious activity.
Go to Administration > Access Configuration > IP Defense to find these features.
DoS Prevention
This area of the Access Configuration window engages a set of rules at the firewall that prevents Denial-of-Service attacks by limiting the amount of new connection requests to the device.
Field Description
Enabled
Per Minute
Enables DoS prevention (enabled by default).
Allowed number of new connections per minute until burst points are consumed. For example, if 60 new connections are received in a minute, decrement one burst point. If no more burst points, drop the packet.
96 mPower TM Edge Intelligence Conduit AEP Software Guide
ADMINISTRATION
Field
Burst
Description
Number of allowed burst for traffic spikes. A burst occurs when the Per Minute limit is reached. On a period where the Per Minute limit is not reached, one burst point is regained, up to the maximum.
Ping Limit
This area of the Access Configuration window engages a set of rules at the firewall that aims to prevent ping flood attacks by limiting the number of ICMP requests to the device. These rules that mitigate the effects of a ping DoS on your device do not apply if ICMP is disabled.
Field Description
Enabled Enables the Ping Limit feature (enabled by default).
Per Second
Burst
Allowed number of pings per second before burst points are consumed. Once burst points run out, ICMP packets will be dropped.
Number of burst points. On a period where the Per
Second limit is not reached, one burst point is regained, up to this maximum.
Brute Force Protection
This feature tracks login attempts at the RESTFUL API level. Its purpose is to prevent Dictionary attacks that attempt to brute force the user's password.
Field Description
Enabled
Attempts
Enables the Brute Force Prevention feature (enabled by default).
The number of failed attempts allowed before the user's account is locked out.
Lockout Minutes The number of minutes an account is locked out before a new login attempt will be accepted.
Bootloader Protection
To see or set these features, go to Administration > Access Configuration > Bootloader Protection and click Show.
Bootloader Password
This feature enables password authentication to access the device bootloader. It is disabled by default.
Field
Enable
Password
Confirm
Description
Enables the Bootloader Password feature to the right of
Authentication Status (enabled by default).
Enter password to access the device bootloader.
Enter the password again to confirm.
Debug Console mPower TM Edge Intelligence Conduit AEP Software Guide 97
ADMINISTRATION
This feature allows the customer to run Silent Mode which turns off the output to the Debug Console . The console output is enabled by default (i.e.
Silent Mode is disabled).
When Silent Mode is enabled, Debug Console is turned off. ( NOTE: During boot, the device does not output any information after the notice that the Linux Kernel is being decompressed including no login prompt, etc.)
Field
Enable
Description
Enables Silent Mode which turns off output to the
Debug Console (disabled by default meaning Debug
Console output is on).
After making all your desired changes, click Submit , then click Save and Restart .
RADIUS Configuration
The RADIUS protocol supports authentication, user session accounting, and authorization of users to the device.
This authentication, accounting, and authorization is independent of the local users created on the device. The user can enable Authentication, Accounting, or both options.
RADIUS user details:
Access to device if role is one of those in the provided list (Administrator, Engineer, or Monitor).
All RADIUS users do not have SSH access to the device.
RADIUS creates a temporary session instead of a local account like local users.
RADIUS uses shared key encryption.
Local users shall take priority over RADIUS user (if a RADIUS user has the same username as a local user, the
RADIUS user cannot log in even if the local user is disabled).
RADIUS user with Administrator role can view and modify all local users (but cannot delete a local
Administrator if it is the only local admin user on the device).
RADIUS users with Engineer and Monitor role cannot view or modify user details. They do not have access to the User Accounts page.
RADIUS users cannot change their own password in the Web UI.
To set up the RADIUS server configuration:
1.
Go to Administration > RADIUS Configuration .
2.
To enable authentication, check Enable Authentication .
3.
To enable accounting, check Enable Accounting .
4.
Enter the following fields for RADIUS configuration : a.
Primary Server b.
Authentication Port (for Primary Server) c.
Accounting Port (for Primary Server) d.
Secondary Server e.
Authentication Port (for Secondary Server) f.
Accounting Port (for Secondary Server)
5.
Under Options , enter the following fields:
98 mPower TM Edge Intelligence Conduit AEP Software Guide
ADMINISTRATION a.
Shared Secret Key value is used to: 1) encrypt packets between the RADIUS Server and device, 2) encrypt RADIUS attributes such as user password, and 3) verify that RADIUS messages have not been modified in transit. This value must be equal to the shared secret that is set up in RADIUS server. The
Shared Secret Key can be up to 128 characters long. You can click the eye icon to hide the key.
b.
Authentication Protocol: select from drop-down list including PAP , EAP-PEAPv0/MSCHAPv2 , or EAP-
TTLS/PAPv0 c.
Timeout is the interval in seconds between tries to connect to RADIUS server in case of communication failure. Maximum is 10 seconds.
d.
Retries is the number of tries to connect to RADIUS server in case of communication failure.
6.
Advanced Options are used when Authentication Protocol is EAP-PEAPv0/MSCHAPv2 or EAP-TTLS/PAPv0.
If Protocol is PAP, these settings are ignored: a.
Check Use Anonymous ID if you want to enable identity privacy. The device does not send its identity in plain text before the device has authenticated the RADIUS server.
b.
Anonymous ID is a name or value that the device will use in the identity response when “Use
Anonymous ID” is enabled.
c.
Check Check Server Certificate Hostname to allow the server certificate CN (common name) to be validated by the device.
7.
Click Submit .
8.
To save your changes, click Save and Restart
Generating a New Certificate
Because the device uses a self-signed website certificate, your browser shows a certificate error or warning. Ignore the warning and add an exception or add your device address to the trusted sites.
To generate a new certificate:
1.
Go to Administration > X.509 Certificate . The X.509 Certificate window displays the details of the certificate that is currently used.
2.
Click Generate to open the Generate Certificate window.
3.
In the Common Name field, enter the name, hostname, or IP address, depending on what you use to connect to the device. The web browser uses this field to check for a valid certificate.
4.
In the Days field, enter the amount of days before the certificate will expire.
5.
In the Country field, enter the 2-letter code for the country name.
6.
In the State/Province field, enter the state or province for which the certificate is valid.
7.
In the Locality/City field, enter the locality or the city for which the certificate is valid.
8.
In the Organization field, enter the organization name for which the certificate is valid.
9.
In the Email Address field, enter the email address of the person responsible for the device. Typically this is the administrator. This field may be left blank.
10.
Click Generate . Wait until the certificate is generated. You may have to reboot to complete the operation.
11.
If you are finished making changes, click Save and Restart .
Importing a Certificate
To import a certificate (in .pem
format): mPower TM Edge Intelligence Conduit AEP Software Guide 99
ADMINISTRATION
1.
Go to Administration > X.509 Certificate . The Certificate window displays the details of the certificate that is currently used.
NOTE: A certificate with a key size greater than 2048 bits causes a delay accessing the Web UI after the device starts. A certificate with a key size less than 2048 bits is not recommended since it is less secure and may become breakable in the near future.
2.
Click Import to open Upload Certificate window.
3.
Click Browse to select a valid certificate to be uploaded. Check that your certificate file format is .pem
.
4.
Click Upload . Wait until the file is uploaded.
5.
To save your changes, click Save and Restart .
NOTE: Your certificate file must be in .pem
format.
Uploading CA Certificate
This page allows a user to upload an X.509 CA (Certifying Authority) Certificate.
To upload a CA certificate:
1.
Go to Administration > X.509 CA Certificates .
2.
Click Choose File and browse for your CA certificate file.
3.
Click Open .
4.
Once your file is selected, click Import .
5.
Your CA certificate file displays in the certificate list along with relevant details.
6.
You may delete or remove a certificate by clicking the trash can icon to the right under Options .
Note: Both add and remove functions may take up to two minutes to update. Once updated, the changes are applied immediately. There is no need to restart the device after CA certificate is added or removed. For bidirectional certificate authentication or client authentication, go to Device Administration > Access Configuration
> HTTPS Security > Authentication and check Client Authentication.
See HTTPS Security on the Access
Configuration page for more details .
Setting up the Remote Management
To modify DeviceHQ automatic update settings, go to options under Auto-Update Settings and refer to Managing
Your Device Remotely.
1.
Go to Administration > Remote Management > Remote Server . To allow the device to connect to the
Remote Management Server, check Enabled .
2.
If you want the device to use a secure connection, check SSL Enabled .
3.
The Server Name field is pre-populated with the address of the Remote Management Server.
4.
The Server Port field is pre-populated with the port the Remote Management Server listens on. You likely do not need to change this.
5.
In the Account Key field, type the account key received from the Remote Management administrator.
The device is not allowed to connect to the Remote Management Server without a valid account key.
6.
Click Submit .
7.
To save your changes, click Save and Restart .
100 mPower TM Edge Intelligence Conduit AEP Software Guide
ADMINISTRATION
Managing Your Device Remotely
DeviceHQ™ can monitor devices, reboot devices, and perform remote software and configuration updates.
NOTE: Reboot the device before performing any firmware updates.
To configure your device to use DeviceHQ:
1.
Go to Administration > Remote Management and check Enabled .
2.
Go to options under DeviceHQ Check-In Settings .
3.
Enable the Intervals check box to check in to DeviceHQ periodically at the specified interval.
*If you do not select Intervals , certain DeviceHQ features will NOT be available .
See note below for details.
a.
To define how often the device connects to DeviceHQ to check in and request any pending updates, set the Check-In Interval field to the desired number of minutes between 240-10080 (240 minutes to 1 week).
Note: Your device must connect to DeviceHQ every 4 hours at a minimum. If you set the check-in interval to less than 4 hours, your change is ignored.
b.
To define how often the device connects to DeviceHQ to send GPS data, set the GPS Data Interval field to the desired number of minutes, between 240-10080 (240 minutes to 1 week).
Note: Some
MTR models do not have GPS. Then this field does not display.
4.
Enable Single Check-In to configure your device to check-in to DeviceHQ at the specific date and time. If you enable Single Check-In , click the Date field to select the date from the calendar picker, and then enter the Time (HH:MM) for your device to check-in.
5.
Enable Repeatable to check-in to DeviceHQ periodically at the specified time daily or at the specific days of the week.
a.
Select Daily from the Repeat drop-down to check in to DeviceHQ every day, and enter the Time
(HH:MM) for your device to check-in.
b.
Select Custom from the Repeat drop-down, then specify the days of the week, and enter the Time
(HH:MM) for your device to check-in.
6.
Go to options under Update Settings
7.
If Sync with Dial-On-Demand is checked and cellular dial-on-demand is enabled, the connection is not dialed solely for the purpose of connecting to DeviceHQ. The device will connect to DeviceHQ only when other traffic brings up the link.
8.
Check Allow Firmware Upgrade if you want DeviceHQ to make automatic updates of your firmware.
9.
Check Allow Configuration Upgrade if you want DeviceHQ to make automatic updates of your configuration software.
10.
Check Allow Radio Firmware Upgrade if you want DeviceHQ to make automatic updates of your cellular radio firmware.
11.
Click Submit .
12.
Click Save and Restart to save your changes.
*NOTE : If you do not select Intervals , certain DeviceHQ features will NOT be available including: missed check-in alerts device rebooted alerts automatically scheduled device log uploads home page notices for rebooted or missed check-in devices mPower TM Edge Intelligence Conduit AEP Software Guide 101
ADMINISTRATION
102
Notifications
The device can send alerts via email, SMS, and/or SNMP. To use these options, enable SMTP (see
for details), SMS (see
for details), and SNMP Traps (see
for details).
A time stamp is added to the actual notifications. The format is YYYY-MM-DD HH:MM .
To setup notifications:
1.
Go to Administration > Notifications > Configuration .
2.
Under Recipient Group , click Add Group (you must add a group before you can edit/save your alert).
3.
In the Create Recipient Group window, enter your Group Name .
4.
Click Add Phone . Enter the person's Name and Phone Number . Then click Finish .
5.
Click Add Email . Enter the person's Name and Email . Then click Finish .
6.
Add name, phone number and email for each person in your group. When done, click Submit .
7.
See the list of available alerts:
High Data Usage
Low Signal Strength
Device Reboots
Ethernet Interface Failure
Cellular Interface Failure
Ethernet Data Traffic
Cellular Data Traffic
WAN Interface Failover
Ping Failure
Security Violation
Resource Overuse
Wi-Fi Interface Failure*
Wi-Fi Data Traffic*
* Only available on models with Wi-Fi capabilities
8.
Click on the pencil icon under the Edit column for the alert you want to use and configure. The Edit dialog box appears for your chosen alert.
For High Data Usage :
1.
Check Enabled .
2.
Under Data Plan Details , select the Plan Type from the drop down menu which includes Monthly or
Custom Interval .
3.
If you choose Custom Interval , enter the Interval length in days.
4.
Select the Start Date from the calendar picker.
5.
Enter the Limit in MB for data usage.
6.
In Notify At , enter the percentage of the limit that triggers notification to be sent.
7.
Select alert recipients from Recipient Group .
8.
Select how you want to send alerts by clicking Email , SMS , or SNMP .
9.
Click Finish .
mPower TM Edge Intelligence Conduit AEP Software Guide
ADMINISTRATION
10.
To save your changes, click Save and Restart .
For Low Signal Strength :
1.
Check Enabled .
2.
Enter the Signal Threshold in dBm .
3.
Enter the Duration in seconds.
4.
Under Alerts , select the recipients under Recipient Group .
5.
In Notify , enter the frequency of notification (in hours). Default is 24 .
6.
Select how you want to send alerts by clicking Email , SMS , or SNMP .
7.
Click Finish .
8.
To save your changes, click Save and Restart .
For Device Reboots :
1.
Check Enabled .
2.
Under Alerts , select the recipients under Recipient Group .
3.
In Notify , the field for frequency of notification is shown. The predefined value is Always and cannot be modified by the user.
4.
Select how you want to send alerts by clicking Email , SMS , or SNMP .
5.
Click Finish .
6.
To save your changes, click Save and Restart .
For Ethernet Interface Failure :
1.
Check Enabled .
2.
Enter the Duration in seconds.
3.
Under Notification Options , select the recipients from the drop-down in Recipient Group .
4.
In Notify , enter the frequency of notification (in hours). Default is 24 .
5.
Select how you want to send alerts by clicking Email , SMS or SNMP .
6.
Click Finish .
7.
To save your changes, click Save and Restart .
For Cellular Interface Failure :
1.
Check Enabled .
2.
Enter the Duration in seconds.
3.
Under Notification Options , select the recipients from the drop-down in Recipient Group .
4.
In Notify , enter the frequency of notification (in hours). Default is 24 .
5.
Select how you want to send alerts by clicking Email , SMS or SNMP .
6.
Click Finish .
7.
To save your changes, click Save and Restart .
For Ethernet Data Traffic :
1.
Check Enabled .
2.
Enter Interval in hours when alert is sent.
3.
Under Notification Options , select the recipients from the drop-down in Recipient Group .
mPower TM Edge Intelligence Conduit AEP Software Guide 103
ADMINISTRATION
4.
In Notify , the constant value is Always .
5.
Select how you want to send alerts by clicking Email , SMS or both .
6.
Click Finish .
7.
To save your changes, click Save and Restart .
For Cellular Data Traffic :
1.
Check Enabled .
2.
Enter Interval in hours when alert is sent.
3.
Under Notification Options , select the recipients from the drop-down in Recipient Group .
4.
In Notify , the constant value is Always .
5.
Select how you want to send alerts by clicking Email , SMS or both .
6.
Click Finish .
7.
To save your changes, click Save and Restart .
For WAN Interface Failover :
1.
Check Enabled .
2.
Enter the Timeout in seconds.
3.
Select what to Notify On from the drop-down.
4.
Under Notification Options , select the recipients from the drop-down in Recipient Group .
5.
In Notify , the constant value is Always .
6.
Select how you want to send alerts by clicking Email , SMS or SNMP .
7.
Click Finish .
8.
To save your changes, click Save and Restart .
For Ping Failure :
1.
Check Enabled .
2.
Under Ping Details , select the Network Interface from the drop-down.
3.
Enter the IP Address or URL that you want to ping.
4.
Enter the Count .
5.
Enter the Failure Threshold .
6.
Enter the Ping Interval .
7.
Under Notification Options , select the recipients from the drop-down in Recipient Group .
8.
In Notify , the constant value is Always .
9.
Select how you want to send alerts by clicking Email , SMS or SNMP .
10.
Click Finish .
11.
To save your changes, click Save and Restart .
For Security Violation :
1.
Check Enabled .
2.
Under Notification Options , select the recipients from the drop-down in Recipient Group .
3.
In Notify , the constant value is Always .
4.
Select how you want to send alerts by clicking Email, SMS , or SNMP.
104 mPower TM Edge Intelligence Conduit AEP Software Guide
mPower TM Edge Intelligence Conduit AEP Software Guide
ADMINISTRATION
5.
Click OK.
For Resource Overuse :
1.
Check Enabled .
2.
Under Notification Options , select the recipients from the drop-down in Recipient Group .
3.
In Notify , the constant value is Always .
4.
Select how you want to send alerts by clicking Email, SMS , or SNMP.
5.
Click OK.
The following notifications are only available on models with Wi-Fi capabilities:
For Wi-Fi Interface Failure :
1.
Check Enabled .
2.
Enter the Duration in seconds.
3.
Under Notification Options , select the recipients from the drop-down in Recipient Group .
4.
In Notify , enter the frequency of notification (in hours). Default is 24 .
5.
Select how you want to send alerts by clicking Email , SMS or SNMP .
6.
Click Finish .
7.
To save your changes, click Save and Restart .
For Wi-Fi Data Traffic :
1.
Check Enabled .
2.
Enter Interval in hours when alert is sent.
3.
Under Notification Options , select the recipients from the drop-down in Recipient Group .
4.
In Notify , the constant value is Always .
5.
Select how you want to send alerts by clicking Email or SMS .
6.
Click Finish .
7.
To save your changes, click Save and Restart .
Customizing the User Interface
You can change how the user interface on your device appears. To change the interface:
1.
From the Navigation pane, select Administration > Web UI Customization .
2.
To define what information appears on the Administration: Support page, use the Support group. See
Customizing Support Information .
3.
To define other settings, use the Device Settings group. See
.
Customizing Support Information
To customize the interface displaying information that can be used to support users:
1.
To enable display of the custom support information, go to Administration > Web UI Customization >
Support Information and check Show Custom Info .
2.
Type the desired information into the optional fields including:
Company Name
105
ADMINISTRATION
106
Country
Fax
Address 1
Address 2
City
State/ Prv
Zip Code
City
3.
To add a phone number: a.
Click Add Phone .
b.
A label can appear next to the phone number, for example Fax or Phone or International . In the
Label field, enter text that describes the phone number.
c.
In the Number field, type the phone number.
4.
To add a link to a website, click Add Link .
a.
To label the website, type label text in Label field.
b.
In the URL field, type the website's link.
c.
To add further descriptive text about the site, type the information in the Text field.
5.
To add an image, click Upload Image: a.
Click Browse , go to the location of the image, and select the image.
b.
Click OK.
6.
To delete an existing image, click Remove Image .
7.
Click Submit .
8.
To save your changes, click Save and Restart .
Specifying Device Settings
To define other custom settings for devices:
1.
Go to Administration > Web UI Customization > Device Settings .
2.
Enter desired information in the optional fields including:
Device Name
Custom ID
Button Color
Button Font Color
Highlight Color
Highlight Font Color
Note: To define color fields, use #rrggbb format.
3.
To add a favorite icon, also known as a shortcut icon or bookmark icon, in the Custom Favicon field, click
Browse to find where the Favicon file resides, select the desired file, and click Upload Icon .
4.
To remove an existing favorite icon, click Remove Icon .
mPower TM Edge Intelligence Conduit AEP Software Guide
ADMINISTRATION
5.
To add a custom logo, next to the Custom Logo field, click Browse to find where the logo file resides, select the desired file, and click Upload Logo .
6.
To remove an existing logo, click Remove Logo .
7.
Click Submit .
8.
To save your changes, click Save and Restart .
Upgrading Firmware
Before upgrading : reboot the device.
Upgrade the device's firmware to the latest version. You can download firmware upgrades from the MultiTech website or update your firmware automatically through MultiTech's DeviceHQ™ system.
For added security, Signed Firmware Validation is automatically used once it's enabled after upgrading from version 5.1 and higher. This authentication method prevents attempts to load invalid or damaged firmware files in order to defeat possible tampering. The module does not load any firmware that MultiTech did not digitally sign.
First, check your firmware version. Refer to the top of your configuration software window. To upgrade the firmware on your device:
1.
Before you upgrade your firmware, save your present configuration as a backup. Otherwise, see
DeviceHQ .
2.
Go to the MultiTech website, locate the firmware upgrade file you want for your device, and download this file to a known location.
3.
Select Administration > Firmware Upgrade . The Administration: Firmware Upgrade pane opens.
4.
Click the Choose Firmware Upgrade File button: a.
Click Browse to find where the firmware file resides that you want to apply.
b.
Select the file and click Open . The file name appears next to the Choose Firmware Upgrade File button. Make sure you select the correct BIN file; otherwise, your device can become inoperable.
5.
Click Start Upgrade .
6.
A message about time needed to upgrade appears. Click OK . A progress bar appears indicating the status of the upgrade. When upgrade is completed, your device reboots.
7.
After the firmware upgrade is complete, verify your configuration to make sure it is what you expected.
Note:
The new firmware is written into flash memory.
It may take up to 10 minutes to upgrade the firmware. Do not interfere with the devices's power or press the reset button during this time.
The DeviceHQ is a cloud platform that provides the ability to remotely manage and upgrade devices.
Please see the Remote Management section or visit www.devicehq.com
for more information.
Saving and Restoring Settings
To restore previous configuration settings to your device, to restore settings to their factory defaults, or to save the current configuration:
1.
Go to Administration > Save/Restore > Save and Restore Configuration .
2.
To restore a configuration from a previously saved file, go to Restore Configuration From File : mPower TM Edge Intelligence Conduit AEP Software Guide 107
ADMINISTRATION a.
Next to the Restore Configuration field, click Browse .
b.
Navigate to the location where the configuration file is stored and select the desired file.
c.
Click Restore . The device reboots.
3.
To save your current configuration to a file, go to Save Configuration To File : a.
Click Save .
b.
Navigate to the location where you wish to save the file and select location.
4.
This option is only available if you had reset to user-defined configuration. (Also, holding the reset button on the device for 30 seconds overrides user-defined settings and resets to factory default.) To reset the device's configuration to the factory settings, go to Reset to Factory Default Configuration : a.
Click Reset .
b.
A dialog box appears prompting you to confirm that you want to restore to factory default settings.
c.
Click OK .
5.
This option is only available if you set user-defined settings first. (Also, holding the reset button on the device for 5 seconds sets user-defined defaults) To restore the device's configuration to the user-defined configuration settings, go to Reset to User-Defined Configuration : a.
Click Restore .
b.
A dialog box appears prompting you to confirm that you want to restore to a set of user-defined settings.
c.
Click OK .
6.
To set deployment-specific default settings, click Set Current Configuration As User-Defined Default .
a.
A dialog box appears prompting you to confirm that you want to restore to a set of user-defined settings.
b.
Click OK .
7.
To save a current configuration: a.
Click Save .
b.
A dialog box appears asking you if you want to open or save the configuration file. Click Save .
c.
Navigate to the location where you want to store the configuration. Click Save .
d.
A progress dialog box appears to indicate that the configuration is being saved. Click Close .
Using the Debugging Options
The device has utilities to help troubleshoot and solve technical problems. You can set up your device:
To automatically reboot itself at a particular time of day or use a particular offset in hours from boot.
To record and report Syslog messages that can help you resolve potential issues with your device.
You can also communicate directly with the device's cellular radio. To do this:
1.
From Administration , select Debug Options .
2.
Click the down arrow to the far right of the Radio Terminal screen to view the terminal window.
3.
Enter AT commands to the radio.
108 mPower TM Edge Intelligence Conduit AEP Software Guide
ADMINISTRATION
See other topics for additional Debug Options:
Auto Reboot Timer (automatically reboot device)
Remote Syslog (configuring syslog)
Ping and Reset Options
Statistics Settings
See also:
Statistics Configuration Fields
Automatically rebooting the device
To choose a specific time to reboot daily, the amount of time that passes before the device automatically reboots itself, or to disable this function:
1.
Go Administration > Debug Options > Auto Reboot Timer , select DAILY, TIMER, or DISABLED from the drop-down under Auto Reboot .
2.
If you chose DAILY , enter the Time of day you want device to reboot (in HH:MM format).
3.
If you chose TIMER , enter the Interval (in hours) for the amount of time that passes before the device automatically reboots itself.
4.
If you do NOT want the device to automatically reboot, select DISABLED (default).
Configuring Remote Syslog
To enable and configure Remote Syslog to capture and send log data from your device, you must have local syslog software installed.
To set up a log request in DeviceHQ, under Devices , select your device. Then click on Tasks and select Request
Device Logs . After the request has been completed, return to the device administration software.
1.
To activate Remote Syslog , go to Administration > Debug Options > Remote Syslog , check Enabled .
2.
To enable a remote server to receive and store the device's log data, under Remote Syslog , in the IP
Address field, type the IP address of the desired server.
3.
To determine the amount of log information that is collected, under Logging , in the Debug Log Level , select the type of information from the values in the dropdown menu which includes: Minimum, Error,
Warning, Info, Debug, and Maximum . The system will collect the type of information you specify. For example, Maximum will collect all the log data available while Warning will collect anything that is a warning or above that level.
4.
To download syslog information directly from the device, click Download Logs .
5.
Click Submit .
6.
To save your changes, click Save and Restart .
Statistics Settings
To configure Statistics :
1.
Go to Administration > Debug Options > Statistics .
2.
Enter the Save Timeout in seconds.
3.
Enter the Save Data Limit in megabytes.
4.
Click Submit .
5.
To save your settings, click Save and Restart .
mPower TM Edge Intelligence Conduit AEP Software Guide 109
ADMINISTRATION
110
Statistics Configuration Fields
The device saves the statistics periodically depending on the configured timeout and data limit. By default, the
Save Timeout is set to 300 seconds and the Data Limit is set to 5 MB. For the default scenario, the device saves the data if more than 5 minutes has elapsed, or if more than 5 MB has been sent or received from the last check. The device checks these conditions every minute, but the data is saved only if one of the conditions is met.
Field
Save Timeout
Save Data Limit
Description
The device saves the statistical data when the desired timeout period has elapsed. Default is 300 seconds (5 minutes).
The device saves the statistical data if the data limit is reached. Default is 5 MB.
Ping and Reset Options
Perform a Ping Test
Ping allows you to test the IP address or URL to ensure it is operational.
To perform a ping test:
1.
Go to Administration > Debug Options > Ping .
2.
Enter the IP address or URL of the site you wish to ping.
3.
Under Network Interface , choose from the available drop-down list options including: ANY, LAN,
CELLULAR, and ETHERNET .
4.
Click Ping .
Reset Options
For various reset options, go to Administration > Debug Options > Reset Options:
To reset the modem, click Reset Modem.
To reset Wi-Fi, click Reset Wi-Fi .
To reset Bluetooth, click Reset Bluetooth
Usage Policy
The device shall provide a Usage Policy for the system. The default usage policy reads as follows:
This system is for the use of authorized users only. Individuals using this system without authority, or in excess of their authority, are subject to having all their activities on this system monitored and recorded by system personnel.
Anyone using this system expressly consents to such monitoring and is advised that if such monitoring reveals possible evidence of criminal activity, system personnel may provide the evidence of such monitoring to law enforcement officials.
This policy displays on the login page. You may modify or add language to the policy as needed.
To view or modify the Usage Policy :
1.
Go to Administration > Usage Policy .
2.
The default language appears. You may edit the language directly in the text box.
mPower TM Edge Intelligence Conduit AEP Software Guide
ADMINISTRATION
3.
When completed, click Submit .
4.
To save your changes, click Save and Restart .
If at any time you want to return the device to the default setting, click the Reset to Default button in the bottom right corner. (This reverts the Usage Policy back to the default language.) mPower TM Edge Intelligence Conduit AEP Software Guide 111
STATUS & LOGS
Chapter 12 – Status & Logs
Viewing Device Statistics
The device collects sent/received traffic data for WAN, Cellular, and Ethernet networks. The daily statistical data is stored on the device for a 365-day period. All data that is older than 365 days is automatically deleted.
1.
From Status & Logs on the left side of the Web Management interface, select Statistics .
2.
The application categorizes statistics about your device. To see statistics that appear in a particular category, click the appropriate tab.
System
Ethernet
Wi-Fi
Access Point
Cellular
Serial
Bluetooth
GRE
IPSec
OpenVPN
LoRa
Definitions
A data usage bar chart and a cumulative usage line chart are available for Ethernet, Wi-Fi, and Cellular. The Data
Usage bar chart also shows statistics for data sent and data received. The following list includes some definitions to help you understand some of the data. Not all of the available statistics are listed here or shown in every tab.
Total : Total number of sent/received bytes for a 365-day period.
Today : Total number of sent/received bytes for today.
Sessions : Bytes.
Packets : Number of successfully transmitted (TX) and received (RX) packets.
Errors : Number of errors that occurred. Possibly due to connection issues or network congestion.
Dropped : Number of dropped packets. Possibly due to memory constraints.
Overruns : Number of overruns that occurred. Possibly due to processing constraints.
Frame : Number of invalid packets.
Carrier : Number of signal modulation errors that occurred (possibly due to physical connection).
Collisions : Number of packet collisions that occurred due to network congestion.
Queue Length : Length of the transmit queue.
MTU (Maximum Transmission Unit): the maximum size of packet content (Bluetooth only).
ACL ( Asynchronous Connection-Less ): the typical protocol used for data packets (Bluetooth only).
SCO (Synchronous Connection-Oriented): the typical protocol used for voice (Bluetooth only).
Events : Number of events that occurred on a Bluetooth connection (Bluetooth only).
Commands : Number of commands given to devices on a Bluetooth connection (Bluetooth only).
112 mPower TM Edge Intelligence Conduit AEP Software Guide
STATUS & LOGS
Cumulative and Daily Usage
Click Show Cumulative Usage or Show Daily Usage to display the desired view. Default chart view is Daily Usage for 30-day period.
Timeframe of Chart
Change the time frame for the chart by clicking Start Date or End Date using calendar to set a different date.
Show Log
The associated run-time logs for this section.
LoRa Statistics
The LoRa statistics tab contains Received and Sent statistics for LoRa packets received and sent by the LoRa network server. These statistics can be cleared with the Clear History button. This tab also contains the list of nodes that have joined the network the device is supporting. There are statistics for each node and also status information in this table. This list can be refreshed by clicking on the Refresh Node List button.
Service Statistics
On the Web Management interface side menu, click Status & Logs > Services to display the Service Statistics window. This window shows the configuration (enabled or disabled) and the status of the following services:
DDNS
SNTP
Cellular RTC
TCP/ICMP Keep Alive
Dial-on-Demand
SMTP
SMS
Failover
Mail Log
Mail Log shows the recent email delivery attempts and the mail log details. Mail log entries are sorted by date with the most recent on top. You can select the number of emails to display in the queue. Possible values are 5, 10, 25,
50 , or All emails .
1.
Go to Status & Logs > Mail Log to display the Mail Log window.
2.
To see the delivery details, click the eye icon under Options for the desired email entry.
3.
To delete all mail log entries, click Purge Log .
Note: Logs do not persist through power cycles.
Mail Queue
Mail Queue shows the emails that are waiting to be sent. The most recent email delivery attempts are on top. You can select the number of emails to display in the queue. Possible values are 5, 10, 25, 50 , and All emails. Note:
Logs do not persist through power cycles.
mPower TM Edge Intelligence Conduit AEP Software Guide 113
STATUS & LOGS
1.
Go to Status & Logs > Mail Queue to display the Mail Queue window.
2.
To view the delivery details for an individual email, click the eye icon under Options for the desired email entry.
Notifications Sent
This page displays attempts to send Notifications via email, SMS, or SNMP.
The list includes the following details of each attempted notification: Date, Message, Recipient Group , and the status of the notification under each communication method including Email, SMS , and SNMP . A check indicates success via that method. An X means failure. No symbol or a blank space indicates that method was not attempted.
To view Notifications Sent :
1.
Go to Status & Logs > Notifications Sent .
2.
In the upper right corner, click Refresh to update the list.
3.
To the right of Refresh , click Delete All Notifications if you want to remove all items in the list.
RF Survey
RF survey is not available for LTE models.
If you have a non-LTE device with a SIM card and want to perform an RF Survey, enter this address:
192.168.2.1/rf_survey and follow the instructions below. (The link uses the default IP address for the device upon log in. If you change the IP address of the device, make sure to use that new IP address in the link).
After the RF Survey, you must reset the device in order to restore cellular radio functionality.
The RF Survey tool allows you to view the list of the cell towers that belong to the carrier and their signal quality details such as Signal Level and Signal Noise Ratio. You need a SIM card to acquire the list of available cell towers.
Note: Selecting this tool terminates any existing PPP connection
1.
Enter this address: 192.168.2.1/rf_survey to open the RF Survey page.
The search for the cell towers takes up to 2 minutes. The wait icon displays while the search is in progress.
The cell tower to which the device is currently connected displays at the top of the list.
2.
To view the Signal Strength chart of a carrier, under Options , click the eye icon for the carrier.
The Carrier Details window appears.
This feature helps you decide which area has better signal strength and thus a better location for the device.
3.
After the RF survey, reset your device. Go to Commands > Restart Device .
114 mPower TM Edge Intelligence Conduit AEP Software Guide
APPS
Chapter 13 – Apps
Manage Apps
Manage Apps
The Manage Apps screen under Apps provides information on installed custom applications including the status and version of all the installed applications.
Node-RED Apps
The Node-RED Apps section displays information for the currently running Node-RED application. Only one Node-
RED application can be running at a time on the device.
Node-RED is disabled by default to save system resources. First, check Enabled to enable Node-Red .
If you want to launch Node-RED, click the Launch Node-RED button at the top.
You can also upload applications to DeviceHQTM either as a new application or a new version of an existing application. To upload Node-RED applications to DeviceHQ:
1.
Click Upload . Then select a new app or an update from the drop-down.
2.
Enter the application name
3.
Enter the version .
4.
Enter your DeviceHQ login credentials including email and password .
Note: For security purposes, the credentials are not saved on the device.
5.
Click Upload .
DeviceHQ Login Credentials
Item
Password
Default Value
Blank
Blank
Description
Email address used to login to
DeviceHQ account that administers apps.
Password used to login to DeviceHQ account that administers apps.
Custom Apps
The Custom Apps section contains the list of custom applications currently installed on the device. Each listing contains the information for a particular application including the name, version, status, and info of the application. The status value can be Started, Running, Stopped, Failed, Install Failed, and Start Failed .
Refer to Creating a Custom Application on the MultiTech Developer Resources website for complete instructions on developing, installing, and deploying custom applications.
mPower TM Edge Intelligence Conduit AEP Software Guide 115
Завантажити
Реклама