MultiTech MTR-H6-B19 Cellular Router User Guide
Pubblicità
Pubblicità
MultiConnect
®
rCell 100
MTR-H6 User Guide
MULTICONNECT® RCELL 100 SERIES ROUTER USER GUIDE MultiConnect ® rCell 100 Series Router User Guide
Models: MTR-H6 Part Number: S000555 Version: 4.0
Copyright
This publication may not be reproduced, in whole or in part, without the specific and express prior written permission signed by an executive officer of Multi-Tech Systems, Inc. All rights reserved.
Copyright © 2018 by Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representations or warranties, whether express, implied or by estoppels, with respect to the content, information, material and recommendations herein and specifically disclaims any implied warranties of merchantability, fitness for any particular purpose and non infringement.
Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
Legal Notices
The MultiTech products are not designed, manufactured or intended for use, and should not be used, or sold or re-sold for use, in connection with applications requiring fail-safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or death, significant property damage, or serious physical or environmental damage. Examples of such use include life support machines or other life preserving medical devices or systems, air traffic control or aircraft navigation or communications systems, control equipment for nuclear facilities, or missile, nuclear, biological or chemical weapons or other military applications (“Restricted Applications”). Use of the products in such Restricted Applications is at the user’s sole risk and liability.
MULTITECH DOES NOT WARRANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE UNINTERRUPTED, TIMELY, SECURE OR ERROR FREE, NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR COMMUNICATIONS NETWORK. MULTITECH WILL HAVE NO LIABILITY FOR ANY LOSSES, DAMAGES, OBLIGATIONS, PENALTIES, DEFICIENCIES, LIABILITIES, COSTS OR EXPENSES (INCLUDING WITHOUT LIMITATION REASONABLE ATTORNEYS FEES) RELATED TO TEMPORARY INABILITY TO ACCESS A CELLULAR COMMUNICATIONS NETWORK USING THE PRODUCTS.
Trademarks and Registered Trademarks
MultiTech, and the MultiTech logo, DeviceHQ, and MultiConnect are registered trademarks and Conduit is a trademark of Multi-Tech Systems, Inc. All other products and technologies are the trademarks or registered trademarks of their respective holders.
Contacting MultiTech Knowledge Base
The Knowledge Base provides immediate access to support information and resolutions for all MultiTech products. Visit http://www.multitech.com/kb.go
.
Support Portal
To create an account and submit a support case directly to our technical support team, visit: https://support.multitech.com
.
Support
Business Hours: M-F, 8am to 5pm CT
Country
Europe, Middle East, Africa: U.S., Canada, all others:
By Email
By Phone
+(44) 118 959 7774 (800) 972-2439 or (763) 717-5863
Warranty
To read the warranty statement for your product, visit www.multitech.com/warranty.go
. For other warranty options, visit www.multitech.com/es.go
.
World Headquarters
Multi-Tech Systems, Inc.
2205 Woodale Drive, Mounds View, MN 55112 Phone: (800) 328-9717 or (763) 785-3500 Fax (763) 785-9874 2 MultiConnect ® rCell 100 MTR-H6 User Guide
CONTENTS
Contents
MultiConnect ® rCell 100 MTR-H6 User Guide 3
CONTENTS
4
MultiConnect ® rCell 100 MTR-H6 User Guide
CONTENTS
MultiConnect ® rCell 100 MTR-H6 User Guide 5
CONTENTS
6
MultiConnect ® rCell 100 MTR-H6 User Guide
CONTENTS
MultiConnect ® rCell 100 MTR-H6 User Guide 7
PRODUCT OVERVIEW
Chapter 1 – Product Overview About MultiConnect rCell 100 Series Router
This guide describes the MultiConnect rCell 100 Series Router. Use the rCell family of routers to provide secure data communication between many types of devices that use legacy and the latest communication technologies.
Some device models support: Bluetooth communication to devices with this technology Wi-Fi communication to devices with this technology GPS capability
What's New in This Release Manual version
2.8
3.0
4.0
Update description
Modbus Slave, Cellular Radio Firmware Upgrade (H5 and H6 only) Improvements to Firewall settings, User Accounts, Radius Configuration, and Commissioning Mode (First-Time Setup) Trusted IP, Self-Diagnostic, Signed upgrade file (integrity check), improved security (authentication, encryption, and cipher suites), and more items for Notifications The router has an integrated cellular modem and includes 10/100 BaseT Ethernet and RS-232 serial connectivity.
An image of the device follows: 8
Intended use:
office/home/light industrial
Documentation
The following table describes additional documentation for your device. The documentation is available on the Multi-Tech Installation Resources website at http://www.multitech.com/brands/multiconnect-rcell-100-series .
MultiConnect ® rCell 100 MTR-H6 User Guide
Document User Guide API Developer Guide AT Commands PRODUCT OVERVIEW Description
This document provides an overview, safety and regulatory information, schematics and general device information.
You can use the rCell API to manage configurations, poll statistics, and issue commands. Documentation is available on the MultiTech Developer Resources website at http://www.multitech.net/developer/software/mtr-api-reference/ .
This document describes AT commands that are available for your device. These commands are documented in the Reference Guide part number S000574.
Product Build Options
Product
MTR-H6-B16 MTR-H6-B18 MTR-H6-B19
Description
Supports HSPA+ only (RED compliant) Supports HSPA+, Wi-Fi, and Bluetooth Supports HSPA+, Wi-Fi, Bluetooth, and GPS MultiConnect ® rCell 100 MTR-H6 User Guide 9
PRODUCT OVERVIEW
Descriptions of LEDs
The top panel contains the following LEDs: Power and Status LEDs—The Power LED indicates that DC power is present and the Status LED blinks when the unit is functioning normally.
Wi-Fi—Indicates if the device is serving as a Wi-Fi access point or acting as a Wi-Fi client. Not all models support Wi-Fi.
Modem LEDs—Two modem LEDs indicate carrier detection and link status.
Signal LEDs—Three signal LEDs display the signal strength level of the wireless connection.
Ethernet LEDs—These LEDs are not on the top panel. See the section Ethernet LED Descriptions for descriptions of these LEDs.
LED Indicators
POWER STATUS Wi-Fi CD LS Indicates presence of DC power when lit.
The LED is a solid light when the device is booting up, saving the configuration, restarting, or updating the firmware. When the Status LED begins to blink, the router is ready for use.
Infrastructure mode: The Wi-Fi LED is lit when Wi-Fi AP mode is enabled, unlit when disabled.
The LED flashes rapidly to indicate traffic.
Client mode: The Wi-Fi LED is lit when Wi-Fi client mode is enabled.
The Wi-Fi LED blinks slowly when associated with an Access Point.
The Wi-Fi LED flashes rapidly to indicate traffic.
Carrier Detect. When lit, indicates data connection has been established.
Link Status OFF — No power to the cellular radio SIGNAL Continuously Lit — Not registered Slow Blink (-0.2Hz) — Registered or connected Signal strength for cellular (RSSI range: 0 - 31) ALL OFF — Unit is off, not registered on network, or extremely weak signal (0 <= RSSI < 6).
1 Bar “ON” — Very weak signal (7 <= RSSI <14).
1 Bar and 2 Bar “ON” — Weak signal (15 <= RSSI <23).
1 Bar, 2 Bar, and 3 Bar “ON” — Good signal (24 <= RSSI >= 31).
10 MultiConnect ® rCell 100 MTR-H6 User Guide
PRODUCT OVERVIEW
Side Panel Connectors
The device has connectors on both sides of the housing. The right side of the device contains a SIM card holder, a reset button, a GPS antenna connector, and a cellular-auxiliary antenna connector pair. Depending on the model of your device, the GPS and WiFi antenna connector may or may not appear.
The following shows the right side panel of the device: The following shows the left side panel of the device containing an RS-232 connector, an Ethernet connector, and the power receptacle.
The following table describes the items on the two side panels:
Label
CELL, AUX GPS WiFi SIM RESET RS-232 E-NET
Description
Cellular antenna inputs. Use with the San Jose Technology EEN-301 antenna supplied with the device if ordered as a bundle.
CELL - Primary. AUX - Diversity.
GPS antenna input. Use with the Trimble GPS antenna 66800-52 supplied with the device when ordered as a bundle.
Used only on the B19 model.
Wi-Fi antenna input. Use with the Taoglas Antenna Solutions GW.11.A153 antenna supplied with the device if ordered as a bundle.
Receptacle for a SIM card (Subscriber Identity Module).
Resets the device. Refer to
Device
.
Resetting the Device
or
Resetting User Defined Settings to the
DE 9-pin, female-D Sub through-hole connector.
RJ-45 receptacle for standard Ethernet 10/100 Base-T.
Caution:
Ethernet ports and command ports are not designed to be connected to a public telecommunication network or used outside the building or campus.
MultiConnect ® rCell 100 MTR-H6 User Guide 11
PRODUCT OVERVIEW
12
Label
Power
Description
9-32 VDC power receptacle for provided power cord. The device uses a Globtek GT-41052 1509 9V 1.7A power supply.
Ethernet LED Descriptions
Two Ethernet LEDs are physically on the RJ-45 connector(s). The table that follows describes these LEDs.
Ethernet Link Ethernet Speed Right LED on Ethernet connector. Blinks when there is transmit and receive activity on the Ethernet link. It shows a steady light when there is a valid Ethernet connection.
Left LED on Ethernet connector. Lit when the Ethernet is linked at 100 Mbps.
If it is not lit, the Ethernet is linked at 10 Mbps.
Specifications
MTR-H6
Category General
Performance
Description
HSPA GPRS/EDGE Refer to the following RF Specifications table for details.
Frequency Bands
Radio
Cellular Wi-Fi, Bluetooth
Speed
Packet Data Telit HE910-EUD Murata LBEE5ZSTNC-523 Up to 7.2 Mbps downlink/5.76 Mbps uplink This is theoretical maximum speed.
SMS SMS Point-to-Point Messaging Mobile-Terminated SMS Mobile-Originated SMS
Connectors
Cellular WiFi SIM GPS
Power Requirements 1
Female SMA connectors for cellular Reverse polarity female SMA connectors for Wi-Fi 1.8 V and 3 V SIM holder for mini-SIM card Female SMA connector MultiConnect ® rCell 100 MTR-H6 User Guide
PRODUCT OVERVIEW Category
Voltage
Physical Description
Safety Compliance
Description
7 V to 32 V DC Dimensions Weight
Environment
Operating Temperature 1 Refer to the
Dimensions
8.2 ounces or 230 grams topic that follows.
EMC Compliance -40° C to +60° C Humidity Relative humidity 15% to 93% non-condensing
Certifications, Compliance, Warranty
EN55022 Class B EN55024 UL 201 IEC 60950-1 ANSI/ISA 12.12.01 2013 & CSA C22.2 No. 213 EN 60079-0:2012+A11:2013 Network Compliance Warranty EN 60079-15:2010 GCF Two years 1 Optional power supply must be a Listed ITE power supply marked LPS or Class 2 rated 1.0 A minimum.
Certification does not apply or extend to voltages outside certified range, and has not been evaluated by UL for operating voltages beyond tested range.
2 For information regarding extended range, please contact MultiTech.
Installation in outdoor locations has not been evaluated by UL. UL Certification does not apply or extend to outdoor applications.
Note:
Radio performance may be affected at the temperature extremes. This is considered normal. There is no single cause for this function. Rather, it is the result of an interaction of several factors, such as the ambient temperature, the operating mode, and the transmit power.
RF Specifications (for H6)
Mode Frequency TX (MHz) Frequency RX (MHz) Channels
GSM850 EGSM900 DCS1800 PCS1900 824 to 849 890 to 915 880 to 890 1710 to 1785 1850 to 1910 869 to 894 935 to 960 925 to 935 1805 to 1880 1930 to 1990 128 to 251 0 to 124 975 to 1023 512 to 885 512 to 810
TX - RX Offset (MHz)
45 45 45 95 80 MultiConnect ® rCell 100 MTR-H6 User Guide 13
PRODUCT OVERVIEW Mode Frequency TX (MHz) Frequency RX (MHz) Channels
WCDMA850 WCDMA900 WCDMA2100 824 to 849 880 to 915 1920 to 1980 869 to 894 925 to 960 2110 to 2170
HE910 Telit Transmission Output Power
Band
GSM 850/900 MHz DCS 1800, PCS 1900 MHz EDGE, 850/900 MHz EDGE, 1800/1900 MHz WCDMA 850/900, AWS 1700, 1900/2100 MHz
Power Class
4 (2W) 1 (1W) E2 (0.557W) Class E2 (0.4W) Class 3 (0.25W)
Dimensions
TX: 4132 to 4233 RX: 4357 to 4458 TX: 2712 to 2863 RX: 2937 to 3088 TX: 9612 to 9888 RX: 10562 to 10838
TX - RX Offset (MHz)
45 45 190 14 MultiConnect ® rCell 100 MTR-H6 User Guide
Labels
The images that follow show regulatory information for your device.
PRODUCT OVERVIEW
MultiConnect ® rCell 100 MTR-H6 User Guide 15
PRODUCT OVERVIEW
16 MultiConnect ® rCell 100 MTR-H6 User Guide
PRODUCT OVERVIEW
Power Draw
Radio Protocol Cellular Cell Box Connection No Data (Amps) (AVG) Measured Current (Amps) at Max Power TX Pulse (AVG) Amplitude Current (Amps) for GSM850 or Peak Current for HSDPA) Total Inrush Charge Measured in Millicoulomb (mC) 7.0 Volts GSM 850 MHz HSDPA 9.0 Volts GSM 850 MHz HSDPA 32.0 Volts GSM 850 MHz HSDPA
0.239
N/A 0.206
N/A 0.067
N/A 0.589
0.797
0.315
0.606
0.151
0.185
1.67
0.808
1.06
0.624
0.356
0.188
2.09
N/A 1.86
N/A 0.720
N/A Note: Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source when determining product load. The above power draw numbers are measurements from an MTR-H6-B19.
MultiConnect ® rCell 100 MTR-H6 User Guide 17
SAFETY WARNINGS
Chapter 2 – Safety Warnings Lithium Battery
A lithium battery (3V, coin cell, CR1632) located within the product provides backup power for the timekeeping. This battery has an estimated life expectancy of ten years.
When this battery starts to weaken, the date and time may be incorrect.
Battery is not user replaceable. If the battery fails, the device must be sent back to MultiTech Systems for battery replacement.
Lithium cells and batteries are subject to the Provisions for International Transportation. Multi-Tech Systems, Inc. confirms that the Lithium batteries used in the MultiTech product(s) referenced in this manual comply with Special Provision 188 of the UN Model Regulations, Special Provision A45 of the ICAO-TI/IATA DGR (Air), Special Provision 310 of the IMDG Code, and Special Provision 188 of the ADR and RID (Road and Rail Europe).
CAUTION:
instructions.
Attention:
Risk of explosion if this battery is replaced by an incorrect type. Dispose of batteries according to Risque d'explosion si vous remplacez la batterie par un modèle incompatible. Jetez les piles usagées selon les instructions.
Ethernet Ports
CAUTION:
network.
Ethernet ports and command ports are not designed to be connected to a public telecommunication
User Responsibility
Respect all local regulations for operating your wireless device. Use the security features to block unauthorized use and theft.
Power Supply Caution
CAUTION:
modem and void your warranty. Adapter shall be installed near the equipment and shall be easily accessible.
CAUTION:
Do not replace the power supply with one designed for another product; doing so can damage the Pour garantir une protection continue contre les risques d'incendie, remplacez les fusibles uniquement par des fusibles du même type et du même calibre. L'adaptateur doit être installé à proximité de l'appareil et doit être facilement accessible.
Device Maintenance
Do not attempt to disassemble the device. There are no user serviceable parts inside.
When maintaining your device: Do not misuse the device. Follow instructions on proper operation and only use as intended. Misuse could make the device inoperable, damage the device and/or other equipment, or harm users.
Do not apply excessive pressure or place unnecessary weight on the device. This could result in damage to the device or harm to users.
18 MultiConnect ® rCell 100 MTR-H6 User Guide
SAFETY WARNINGS
Do not use this device in explosive or hazardous environments unless the model is specifically approved for such use. The device may cause sparks. Sparks in explosive areas could cause explosion or fire and may result in property damage, severe injury, and/or death.
Do not expose your device to any extreme environment where the temperature or humidity is high. Such exposure could result in damage to the device or fire. Refer to the device specifications regarding recommended operating temperature and humidity.
Do not expose the device to water, rain, or spilled beverages. Unless the device is IP67 rated, it is not waterproof. Exposure to liquids could result in damage to the device.
Do not place the device alongside computer discs, credit or travel cards, or other magnetic media. The information contained on discs or cards may be affected by the device.
Using accessories, such as antennas, that MultiTech has not authorized or that are not compliant with MultiTech's accessory specifications may invalidate the warranty.
If the device is not working properly, contact MultiTech Technical Support.
Vehicle Safety
When using your device in a vehicle: Do not use this device while driving.
Respect national regulations on the use of cellular devices in vehicles.
If incorrectly installed in a vehicle, operating the wireless device could interfere with the vehicle’s electronics. To avoid such problems, use qualified personnel to install the device. The installer should verify the vehicle electronics are protected from interference.
Using an alert device to operate a vehicle’s lights or horn is not permitted on public roads.
UL evaluated this device for use in ordinary locations only. UL did NOT evaluate this device for installation in a vehicle or other outdoor locations. UL Certification does not apply or extend to use in vehicles or outdoor applications.
Notice regarding Compliance with FCC, EU, and Industry Canada Requirements for RF Exposure
The antenna intended for use with this unit meets the requirements for mobile operating configurations and for fixed mounted operations, as defined in 2.1091 of the FCC rules for satisfying RF exposure compliance. This device also meets the European RF exposure requirements of EN 62311. If an alternate antenna is used, consult user documentation for required antenna specifications.
Compliance of the device with the FCC, EU and IC rules regarding RF Exposure was established and is given with the maximum antenna gain as specified above for a minimum distance of 20 cm between the devices radiating structures (the antenna) and the body of users. Qualification for distances closer than 20 cm (portable operation) would require re-certification.
Wireless devices could generate radiation. Other nearby electronic devices, like microwave ovens, may also generate additional radiation to the user causing a higher level of RF exposure.
Radio Frequency (RF) Safety
Due to the possibility of radio frequency (RF) interference, it is important that you follow any special regulations regarding the use of radio equipment. Follow the safety advice given below.
MultiConnect ® rCell 100 MTR-H6 User Guide 19
SAFETY WARNINGS
Operating your device close to other electronic equipment may cause interference if the equipment is inadequately protected. Observe any warning signs and manufacturers’ recommendations.
Different industries and businesses restrict the use of cellular devices. Respect restrictions on the use of radio equipment in fuel depots, chemical plants, or where blasting operations are in process. Follow restrictions for any environment where you operate the device.
Do not place the antenna outdoors.
Switch OFF your wireless device when in an aircraft. Using portable electronic devices in an aircraft may endanger aircraft operation, disrupt the cellular network, and is illegal. Failing to observe this restriction may lead to suspension or denial of cellular services to the offender, legal action, or both.
Switch OFF your wireless device when around gasoline or diesel-fuel pumps and before filling your vehicle with fuel.
Switch OFF your wireless device in hospitals and any other place where medical equipment may be in use.
Interference with Pacemakers and Other Medical Devices
Potential interference
Radio frequency energy (RF) from cellular devices can interact with some electronic devices. This is electromagnetic interference (EMI). The FDA helped develop a detailed test method to measure EMI of implanted cardiac pacemakers and defibrillators from cellular devices. This test method is part of the Association for the Advancement of Medical Instrumentation (AAMI) standard. This standard allows manufacturers to ensure that cardiac pacemakers and defibrillators are safe from cellular device EMI.
The FDA continues to monitor cellular devices for interactions with other medical devices. If harmful interference occurs, the FDA will assess the interference and work to resolve the problem.
Precautions for pacemaker wearers
If EMI occurs, it could affect a pacemaker in one of three ways: Stop the pacemaker from delivering the stimulating pulses that regulate the heart's rhythm.
Cause the pacemaker to deliver the pulses irregularly.
Cause the pacemaker to ignore the heart's own rhythm and deliver pulses at a fixed rate.
Based on current research, cellular devices do not pose a significant health problem for most pacemaker wearers.
However, people with pacemakers may want to take simple precautions to be sure that their device doesn't cause a problem.
Keep the device on the opposite side of the body from the pacemaker to add extra distance between the pacemaker and the device.
Avoid placing a turned-on device next to the pacemaker (for example, don’t carry the device in a shirt or jacket pocket directly over the pacemaker).
Antenna
The antenna intended for use with this unit meets the requirements for mobile operating configurations and for fixed mounted operations, as defined in 2.1091 and 1.1307 of the FCC rules for satisfying RF exposure compliance.
If an alternate antenna is used, consult user documentation for required antenna specifications.
20 MultiConnect ® rCell 100 MTR-H6 User Guide
CELLULAR INFORMATION
Chapter 3 – Cellular Information Antenna System Cellular Devices
The cellular/wireless performance depends on the implementation and antenna design. The integration of the antenna system into the product is a critical part of the design process; therefore, it is essential to consider it early so the performance is not compromised. If changes are made to the device's certified antenna system, then recertification will be required by specific network carriers.
Requirements for Cellular Antennas with regard to FCC/IC Compliance
There cannot be any alteration to the authorized antenna system. The antenna system must maintain the same specifications. The antenna must be the same type, with similar in-band and out-of-band radiation patterns.
This device has been designed to operate with the antennas listed below and having a maximum gain for 850 MHz of <= 6.4 dBi , for 1700 MHz of <= 6.5 dBi, and for 1900 MHz of <= 3 dBi. Antennas not included in this list or that have a gain greater than specified are strictly prohibited for use with this device. The required antenna impedance is 50 ohms.
Antenna Information
This device was approved with the following antenna: Manufacturer: Description: Model Number: Multi-Tech Part Number: San Jose Penta band antenna EEN-301 45009780L
Multi-Tech ordering information: Model
ANPB2-1HRA ANPB2-10HRA ANPB2-50HRA
Quantity
1 10 50
Antenna Requirements/Specifications
Frequency range Impedance VSWR Radiation Polarization 824-960/1710-2170 MHz 50 ohm <2.5:1 Omni directional Linear horizontal MultiConnect ® rCell 100 MTR-H6 User Guide 21
CELLULAR INFORMATION
GPS Antenna Specifications
Manufacturer: Description: Model Number: Multi-Tech Part Number: Trimble GPS Antenna with low noise amplifier 66800-52 45009665L
MultiTech Ordering Information
Model
ANGPS-1MM ANGPS-10MM ANGPS-50MM
Quantity
1 10 50
Antenna Specifications
Category
Frequency Range Impedance VSWR Gain LNA Current Consumption Noise Figure Polarization Input voltage
Description
1575.24 MHz 50 Ohms 2.0:1 max 10-30 dBi 40 mA max < 2dB RHCP 3.0V
M M 0.2V
Bluetooth and Wi-Fi Antennas
Manufacturer: Manufacturer's Model Number: Multi-Tech Systems: Taoglas Antenna Solutions GW.11.A153
45009740L
Multi-Tech Ordering Information
Model Number
ANWF-1HRA ANWF-10HRA ANWF-50HRA
Quantity
1 10 50 22 MultiConnect ® rCell 100 MTR-H6 User Guide
CELLULAR INFORMATION
Antenna Specifications
Category
Frequency Range Impedance VSWR Peak Radiated Gain Radiation Polarization Connector
Description
2.4000 to 2.4835 GHz 50 Ohms VSWR should not exceed 2.0:1 at any point across the bands of operation 2.3 dBi on azimuth plane Omni-directional Linear Vertical RP-SMA(M) MultiConnect ® rCell 100 MTR-H6 User Guide 23
INSTALLING THE ROUTER
Chapter 4 – Installing the Router Installing the SIM Card
If you want to operate the router on a particular network, install a SIM card (Subscriber Identity Module).
To install the SIM:
1.
2.
Locate the SIM card slot on the side of the router. The slot is labeled SIM.
Push the SIM card into the slot until it snaps into place.
24
3.
To remove the SIM, push the edge of the card in. When released, the card pops out of the device.
Installing the Router
1.
2.
3.
4.
5.
6.
7.
8.
9.
To use the router’s cellular features, connect a suitable antenna to the antenna connector.
If your device is capable of supporting antenna diversity, see the section about diversity.
Using an Ethernet cable, connect one end of the cable to the E-NET connector on the back of the router and the other end to your computer, either directly or through a switch or hub.
If you are connecting to a serial interface, connect the DE-9 connector (9-pin) of the RS-232 cable to the RS-232 connector on the router. Then connect the other end to the serial port on the desired device.
Some routers support the use of a GPS receiver. If you are using a GPS receiver with the router, attach the GPS cable to the GPS connector on the router.
Attach a power cable to your power supply module.
Screw-on the power lead from the power supply module into the power connection on the router.
Plug the power supply into your power source.
The POWER LED lights after the device powers up.
When the Status LED begins to blink, the device is ready for use.
You can configure your router by using your router’s web management interface. You might need to change the IP address of your computer to be in the same IP and subnet mask range as the device.
MultiConnect ® rCell 100 MTR-H6 User Guide
INSTALLING THE ROUTER a.
b.
c.
Open a web browser. In the browser's address field, type the default address for the router: http://192.168.2.1. (If the browser displays a message that there is a problem with the website's security certificate, ignore this and click
Continue to the webpage
).
On first-time power up of the device, its Web UI displays the initial setup in commissioning mode requiring a
username
and
password
for the first administrative user. Enter your desired username and password. Refer to
First-Time Setup
for more details.
If you are not powering up the device for the first time and simply upgrading the firmware of your device, your existing logins are still active.
Mounting the Device
1.
2.
3.
Locate the groove on the bottom of the modem.
Slide the mounting rod through the groove.
To secure the rod to the desired surface, place and tighten two screws in the holes on either end of the mounting rod. The dimensions illustration in this guide shows the mounting rod, as well as the dimensions for placement of the screws.
Setting up Wi-Fi
Some models have Wi-Fi capability. If your device supports this feature, you need to use the device’s web management interface to enable Wi-Fi. Then, see the online help file for information on working with Wi-Fi.
Resetting the Device
You need: A pin, paperclip, or similar thin object that can fit into the reset hole The following is the default condition for the RESET button on the device. You can program a change to the behavior of the button if needed.
To reset the device:
1.
2.
Find the hole labeled RESET. The reset button is recessed into the case.
Use the pin to press and release the RESET button as follows: Reset options: To reboot, press RESET for less than 3 seconds.
To reboot and restore user-defined defaults (if previously set), press RESET for 3 to 29 seconds.
To reboot, restore factory settings, and erase user-defined defaults, press RESET for 30 seconds or longer.
The device restarts in commissioning mode. The system automatically removes all user accounts.
Enter a new username and password to create your new administrative account. (Refer to
User Accounts
for more details on username and password requirements.)
Note:
The device reboots when restoring settings.
MultiConnect ® rCell 100 MTR-H6 User Guide 25
INSTALLING THE ROUTER
Restoring User Defined Settings to the Device
You can restore user defined settings to your device.
You need: A pin, paperclip, or similar thin object that can fit into the reset hole
1.
2.
Locate the hole in the panel labeled RESET. The reset button is recessed into the housing.
Use the pin to press in the button for about 3 seconds and then release the reset button.
a.
b.
If you do not press in the button long enough, the device will reset, but the user defined settings will not be restored.
If you hold it too long, factory default settings will be restored.
26 MultiConnect ® rCell 100 MTR-H6 User Guide
USING THE WIZARD TO CONFIGURE YOUR DEVICE
Chapter 5 – Using the Wizard to Configure Your Device First-Time Setup
If you need to change the mode of your device, this is the only way to do so. This section is not available through the device management software.
Other than when you first power up the device, you must configure the device to factory default settings, reset it and then, access it through the default 192.168.2.1 IP address to see the first-time setup. This wizard helps you configure the main features of your device.
Depending on the mode you choose, your proceeding options and fields differ (see the description of each step for details below). Here are the steps for first-time setup:
1.
2.
3.
Upon power up for the first time or after you reset the device and accept factory default settings, the device goes into commissioning mode. The system requires you to set up an admin user. Enter your desired username and click
OK
.
Enter a desired password for the admin user and click strength (with a mix of character classes such as letters, numbers, and symbols). Enter the password again to confirm. Click
OK
.
OK
. This password must be of sufficient length and Next, the mode option lets you set up the product as a
Network Router
,
PPP-IP Passthrough
, or
Serial Modem
device. If you switch modes, we recommend that you reset the device and configure to factory default settings.
a.
b.
The
Network Router
In the mode is the default and establishes the device as a cellular network router.
PPP-IP Passthrough
mode, the rCell assigns the IP address it receives from the cellular provider to the Ethernet-attached device. In this mode, the rCell only allows one DHCP lease.
Note:
In this mode, many of the rCell services described in this document are non-configurable and do not appear in the device configuration menu. All IP traffic is passed between the Ethernet attached device and the cellular provider with no firewall functionality.
c.
d.
The
Serial Modem
mode creates a serial connection to the device which can be configured for speed and flow control. The serial port talks to the cellular radio in order to send and receive messages via the cellular radio.
Click
Next
.
4.
5.
b.
c.
d.
In the
Time Configuration
page, set the date, time, and time zone.
a.
In the opens.
Date
field, type in the date you desire, or select the date from the pop-up calendar that In the
Time
field, type the desired time.
From the
Time Zone
drop-down list, select the time zone in which the router operates.
Click
Next
. Or if you are done making changes, click
Finish
.
In the
IP Setup
page, give the router its address and network information (the fields shown vary based on the selected mode): If you select
PPP-IP Passthrough
mode, the following options are displayed: MultiConnect ® rCell 100 MTR-H6 User Guide 27
USING THE WIZARD TO CONFIGURE YOUR DEVICE 6.
7.
8.
a.
b.
c.
d.
In the
IPv4 Protocol Support
and
IPv6
).
field, choose the internet protocol from the drop down menu (select from In the
Protocol Support
field, choose
IPv4
only as the cell radios for C2 and EV3 do not support
IPv6
.
In the 24).
Mask
field, enter the IP mask (default: 255.255.255.255 for mask 32, 255.255.255.0 for mask In the
IPv6/IPv4 Primary DNS
field, type the address of the primary DNS (optional).
Note:
This is an optional value that can be used if you use a DNS server other than the servers received from your carrier.
e.
f.
In the Click
Public IPv4 Mask Next
field, select the public mask from the drop down either . Or if you are done making changes, click
Finish
.
32
or If you select
Network Router
or
Serial Modem
mode, the following options are displayed:
24
.
a.
b.
c.
In the
IP Address
field, type the router's IP address.
In the
Mask
field, type the mask for the network. The default is 255.255.255.0.
This field is only available in In the
IPv4 Primary DNS Network Router
mode. If you select
Serial Modem
field, type the address of the primary DNS (optional).
mode, skip this step.
Note:
This is an optional value that can be used if you use a DNS server other than the servers received from your carrier.
d.
Click
Next
. Or if you are done making changes, click
Finish
.
This section is only available if you select
Serial Modem
mode, skip this step. In the
Network Router
or
PPP Configuration PPP-IP Passthrough
mode. If you select page, configure PPP for your router.
a.
b.
c.
d.
e.
This section is only available if you select
Serial Modem Network Router
or
PPP-IP Passthrough
mode, skip this step. In the PPP Authentication page: mode. If you select
a.
b.
c.
To use PPP, check
Enabled
. When enabled, your device functions as a router.
For devices that use two antennas,
Diversity
is enabled by default. Diversity enables the use of two cellular antennas for better performance. ( See
Installing the Router
for more details).
To enable the dial-on-demand feature, check up the PPP connection when there is outgoing IP traffic, and take down the PPP connection after a given idle timeout.
Dial-on-Demand
. This indicates to the router to bring In the
APN
field, type the APN (Access Point Name). The APN is assigned by your wireless service provider (not applicable to LVW2 and certain Verizon devices).
Click
Next
. Or if you are done making changes, click
Finish
.
From
Type
, select the authentication protocol type used to negotiate with the remote peer:
CHAP, or PAP-CHAP
. The default value is
NONE
.
PAP,
In the
Username
field, type the username with which the remote peer authenticates. You can leave this field blank, if desired. Username is limited to 60 characters.
In the
Password
field, type the password with which the remote peer authenticates. You can leave this field blank, if desired. Password is limited to 60 characters.
This section is only available if you select
Serial Port Configuration
page:
Serial Modem
mode. For any other mode, skip this step. In the 28 MultiConnect ® rCell 100 MTR-H6 User Guide
USING THE WIZARD TO CONFIGURE YOUR DEVICE a.
b.
c.
d.
e.
From
Baud Rate
, select baud rate in BPS for the serial port from the drop down list. Default setting is
115200
.
In the from
Flow Control NONE
or field, select the flow control option from the drop down list provided. Choose
RTS-CTS
.
In the
EVEN
.
Parity
field, select the parity option from the drop down list. Choose from
NONE
,
ODD
, or In the
Data Bits
field, select the data bits option from the drop down list. Choose from
7
or
8
.
In the
Stop Bits
field, select the stop bit option from the drop down list. Choose from
1
or
2
.
9.
10.
Click
Finish
.
To save your settings, click
Save and Restart
.
MultiConnect ® rCell 100 MTR-H6 User Guide 29
CONFIGURING YOUR DEVICE
Chapter 6 – Configuring Your Device Home Page (Dashboard)
The Home page (dashboard) displays a summary of the configuration settings for the MultiConnect rCell device.
The following settings, where applicable, include the area of the Web Management interface where they can be accessed and changed.
Click
Home
to display the following information:
Router
:
Model Number
: The MultiConnect rCell model ID.
Serial Number
: The MultiTech device ID.
IMEI
: International Mobile Station Equipment Identity.
Note:
Not applicable for the MTR-C2 or MTR-EV3 models.
Firmware
: MultiConnect rCell MTR firmware version.
Current Time
: Current date and time of the router. For information on setting the date and time, go to
Setup > Time Configuration
.
Up Time
: Amount of time the device has been continuously operating.
WAN Transport
: Current transport for IP traffic leaving the LAN. If two WAN interfaces are configured for use (Wi-Fi and cellular), the current WAN will be set based on the WAN configurations at
Setup > WAN Configuration.
LAN
:
MAC Address
: Media Access Control Address used to uniquely identify the devices LAN Ethernet interface.
IP Address
: LAN IP address of this device. To configure the IP address, go to
Setup > IP Configuration
.
Netmask
: Network mask of the LAN. To configure the network mask, go to
Setup > IP Configuration
.
Gateway
: Default gateway IP address of the LAN. To configure the default gateway, go to
Configuration
.
Setup > IP DNS
: Current Domain Name System IP addresses known by this device. To configure the DNS, go to
Setup > IP Configuration
.
DHCP State
: Current state of this device's DHCP server. To configure, go to
Setup > DHCP Configuration
.
Lease Range
: Current DHCP lease range of this device's DHCP server. To configure, go to
Configuration
.
Setup > DHCP Cellular
:
Protocol Support
choose
IPv6
(only available when you choose , also enter the
Connect Timeout
.
PPP-IP Passthrough
): Choose from
IPv4
or
IPv6
. If you
Protocol Support
(only available when you choose EV3 as their cell radios do not support
IPv6
.
PPP-IP Passthrough
): Choose only
IPv4
for C2 and
State
: Current state of the cellular PPP link. For more information, go to
Configuration
.
Cellular > Cellular Signal
: Current signal strength of the cellular link. Mouse hover provides dBm value.
Connected
: Total time connected for the current PPP session.
30 MultiConnect ® rCell 100 MTR-H6 User Guide
CONFIGURING YOUR DEVICE IP Address
: Current cellular WAN IP address issued to this device by the cellular carrier.
Roaming
: Indicates whether or not this device's cellular link is currently connected to its home network.
Phone number
: Device's cellular phone number also known as Mobile Directory Number (MDN). This field is blank if the MDN is not stored in the SIM card.
Tower
: Tower ID of the cellular tower currently providing cellular service to this device.
Wi-Fi
:
Mode
: Indicates the current Wi-Fi mode. Options include None, Wi-Fi as WAN, or Wi-Fi Access Point. For configuration go to
Wireless > Wi-Fi
.
MAC Address
: Media Access Control Address used to uniquely identify the Wi-Fi interface. This MAC will be the same as the Ethernet MAC when in Access Point mode.
State
: Current state of the Wi-Fi.
SSID
: In Access Point mode, this is the Service Set Identifier (SSID) for this device's Wi-Fi Access Point. In Wi-Fi As WAN mode, this is the SSID of the Wi-Fi Access Point this device is currently connected to or trying to connect to. For configuration go to
Wireless > Wi-Fi
.
Security
: In Access Point mode, this is the current security protocol of this device's Wi-Fi Access Point. To configure go to
Wireless > Wi-Fi
.
Bluetooth
:
State
: Current state of the Bluetooth link. To configure go to
Wireless > Bluetooth
.
MAC Address
: Media Access Control Address used to uniquely identify the Bluetooth interface.
Device Name
: Name of Bluetooth device configured to link to. For configuration go to
Bluetooth
.
Wireless >
Device MAC
: Media Access Control Address of the Bluetooth device configured to link to. To configure go to
Wireless > Bluetooth
.
Time Configuration
You can configure how your device manages the setting of time on its domain of systems. The system date and time display in these formats:
MM/DD/YYYY / HH:MM
. You can set the date and time manually, or you can configure the device to get this information from a cellular RTC (real time clock) or an SNTP server.
Setting the Date and Time
To set the device's date and time:
1.
2.
3.
4.
5.
6.
From
Setup
, select
Time Configuration
.
In the
Date
field, type in the date you desire, or select the date from the pop-up calendar that opens.
In the
Time
field, type the time.
From the
Time Zone
drop-down list, select your time zone. The default selection is UTC (Universal Coordinated Time, Universal Time).
Note:
To learn more about time zones, visit the following website : http://wwp.greenwichmeantime.com/info/current-time.htm
Click
Submit
.
To save your changes, click
Save and Restart
.
MultiConnect ® rCell 100 MTR-H6 User Guide 31
CONFIGURING YOUR DEVICE
Configuring SNTP to Update Date and Time
To configure the server from which the SNTP date and time information is taken, and how often:
1.
2.
3.
4.
5.
To enable SNTP to update the date and time, check
Enabled
.
In the
Server
field, type the SNTP server name or IP address that is contacted to update the time.
In the
Polling Time
field, type the time that passes (in minutes), after which the SNTP client requests the server to update the time. Default is 120 minutes.
Click
Submit
.
To save your changes, click
Save and Restart
.
Unavailable Services in PPP-IP Passthrough and Serial Modem Modes
In both
PPP-IP Passthrough
and
Serial Modem
modes, many rCell services described in this document are non configurable and therefore do not appear in the device configuration menu. If you choose one of these modes, all sections between this and the next note on this subject are not available.
Configuring IP Address and DNS Information for LAN
Your router manages traffic for your local area network (LAN). To change the IP address and DNS configuration:
1.
2.
3.
4.
5.
From
Setup
, select
IP Configuration
.
To configure the address LAN information: In the
IP Address
field, type the router's IP address. The default is 192.168.2.1.
In the
Mask
field, type the mask for the network. The default is 255.255.255.0.
In the
Gateway
field, type the IP address of the network's gateway (router). If this device is the gateway, leave this field blank.
To resolve domain names, configure domain name server information (DNS).
To allow the router to behave as a local DNS forwarder, check
Enable Forwarding Server
.
Note:
When a DNS request is received, the router forwards the request to a remote DNS server if there is no record in the router’s cache. New requests are cached in the router for future requests.
In the
Primary Server
field, type the address of the primary DNS.
In the
Secondary Server
field, type the address of the secondary DNS.
The
WAN DNS Servers
field displays information about DNS servers, if any, that have been detected on the WAN link of the router.
Click
Submit
.
To save your changes, click
Save and Restart
.
WAN Setup
Configuring WAN Failover Priority
Failover mode regulates which WAN is used for the Internet connection and switches the WAN if a connectivity failure is detected.
32 MultiConnect ® rCell 100 MTR-H6 User Guide
CONFIGURING YOUR DEVICE
Failover mode enables the WAN with the highest priority as displayed on the establishing connection to the Internet.
WAN Configuration
page. If the WAN with priority 1 is disabled or a connection failure is detected, the WAN with priority 2 is automatically selected for Wi-Fi as WAN is priority 1 by default.
If Ethernet is used as WAN, the DHCP server must be disabled.
1.
2.
3.
Click
Setup > WAN Configuration
.
Under
Options
, click the up and down arrows to change the priority of the appropriate WAN.
Click
Save and Restart
to save the change.
For field descriptions see
For information on editing WAN Failover see
Editing Failover Configuration
Editing Failover Configuration
The device can use the active or passive mode to monitor the Internet availability in WAN. The default condition is active mode.
Active mode can be type ICMP (ping) or TCP. ICMP periodically pings the designated host at the specified interval.
TCP tries to make a connection to the designated host at the interval specified.
For both ICMP and TCP, if a response is not received, the device switches to the WAN with lower priority. The device continues to ping the designated host at the interval specified for WAN with the higher priority and switches back when the ping is successful. When passive mode is enabled, the device switches the WANs when the network interface is down. The currently active WAN is displayed on the home page under the label WAN Transport.
To edit failover configuration:
1.
2.
3.
4.
5.
Click
Setup > WAN Configuration
Under the
Options Configuration
column at the right, click the pencil icon (edit) for the selected WAN. The page is displayed.
.
Make the desired changes. Refer to
for details.
Click
Finish
.
If you are finished making changes, click
Save and Restart
.
Failover
Failover Configuration Fields
Field Monitoring Mode Interval Host Name Mode Type TCP Port Description
Use the drop-down list to select the mode to connect to the host: PASSIVE or ACTIVE.
Enter the number of seconds between each check. Default is 60 seconds.
Enter the host name or IP address to use for the check. Default is www.google.com.
Use the drop-down list to select the mode type: ICMP or TCP. Default is ICMP.
(Active Monitoring Mode) Enter the TCP Port number to connect to the host. (Mode TCP) MultiConnect ® rCell 100 MTR-H6 User Guide 33
CONFIGURING YOUR DEVICE
34
Field ICMP Port Description
Enter the number of ICMP pings to be sent to the specified host. Default is 10.
(Mode ICMP)
Configuring Dynamic Domain Naming System (DDNS)
This feature allows your router to use a DDNS service to associate a hosted server's domain name with a dynamically changing internet address. To configure your router to use DDNS:
1.
2.
3.
From
Setup
, select
DDNS Configuration
.
In the
Configuration
group, check
Enabled
.
In the
Service
drop-down list, select a DDNS service. To define a service that isn't listed choose
Custom
.
a.
b.
For custom DDNS service, in the
Service
field, type the DDNS server's URL.
For custom DDNS service, in the
Port
field, type the DDNS server's port.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
In the
Domain
field, type the registered Domain name.
In the
Update Interval
field, type the days that can pass with no IP Address change. At the end of this interval, the existing IP Address is updated on the server so that the address does not expire. The range of the interval you can enter is between 1 and 99 days. The default is 28 days.
Check
Use Check IP
The IP address is still assigned by the wireless provider and the DDNS is updated based on the address returned by Check IP Server. If disabled, the DDNS update uses the IP address from the PPP link. The default is , if you want to query the server to determine the IP address before the DDNS update.
Use Check IP
.
In the
Check IP Server
checkip.dyndns.org
field, type the name to which the IP Address change is registered. Example: In the
Check IP Port
field, type the port number of the Check IP Server. The default is 80.
From the
System
drop-down list, select the desired system registration type, either Dynamic or Custom.
The default is Dynamic.
Enter
Username
of the server.
Enter
Password
of the server.
To force update of DDNS, click
Update
.
Click
Submit
.
To save your changes, click
Save and Restart
.
Entering authentication information
Your DDNS server requires you to identify yourself before you can make changes.
1.
2.
3.
In the
Username
field, type the name that can access the DDNS Server. The default is NULL. You receive your name when you register with the DDNS service.
In the
Password
field, type the password that can access the DDNS Server. The default is NULL. You receive your password when you register with the DDNS service.
Click
Submit
. If you are finished making changes click
Save and Restart
.
Forcing a DDNS server update
To update the DDNS server with your IP address, click
Update
.
MultiConnect ® rCell 100 MTR-H6 User Guide
CONFIGURING YOUR DEVICE
Configuring Dynamic Host Configuration Protocol (DHCP) Server
You can configure your device to function as a DHCP server that supplies network configuration information, such as IP address, subnet mask, and broadcast address, to devices on the network. To configure the DHCP server:
1.
2.
3.
4.
5.
6.
7.
8.
9.
From
Setup
, select
DHCP Configuration
.
To use the DHCP feature, check
Enabled
.
The
Subnet
field displays the subnet address.
The
Mask
field displays the network's subnet mask.
In the device.
Gateway
field, type the gateway address. The default Gateway address is the LAN IP address of the In the
Domain
field, type your network domain, if any.
In the
Lease Range Start
assigned by DHCP.
field and in the
Lease Range End
field, type the range of IP addresses to be In the
Lease Time
field, type the DHCP lease time. Lease time is set in days, hours, and minutes.
Click
Submit
. If you are finished making changes, click
Save and Restart
.
Assigning Fixed Addresses
To add fixed addresses for the DCHP server:
1.
2.
3.
4.
5.
In the
Fixed Address
group, click
Add
. A dialog box opens, where you define the address.
In the
MAC Address
field, type the MAC address to which the specified IP address binds.
In the
IP Address
field, type the fixed IP address to be assigned.
Click
Finish
.
To save your changes, click
Save and Restart
.
Configuring the Global Positioning System (GPS)
This GPS information applies only to the MTR models that support GPS including: Model B19 Some routers have a built-in GPS receiver. If your router has a GPS receiver, the router can forward NMEA (National Marine Electronics Association) sentences from the GPS receiver to a device connected to the router's serial port. You can also send the GPS data over the network to a remote computer.
There are four areas of GPS configuration including:
Configuration
and
NMEA Configuration
along with
Server Configuration Current Position
,
Local Configuration
information.
,
Client
Notes: All enabled sentences are forwarded periodically using the interval specified in the GPGLL, GPRMC, GPVTG.
NMEA Configuration
section. Before forwarding, the router adds an ID prefix and ID to each enabled NMEA sentence. If set, the NMEA sentences available are those provided by the built-in receiver which are: GPGGA, GPGSA, GPGSV, You can simultaneously enable the TCP Server, TCP/UDP client, and serial port dump.
GPS Server Configuration
To setup the GPS Server Configuration: MultiConnect ® rCell 100 MTR-H6 User Guide 35
CONFIGURING YOUR DEVICE 1.
2.
3.
4.
5.
6.
Go to
Setup > GPS Configuration > Server Configuration
.
To enable server configuration, check
TCP Server
.
In the
Port
field, type the port number on which the TCP server is listening for connections. The default is
5445
. You can use up to five digits. Each digit itself must be between
0
and
9
. Numbers above
65,535
are illegal as the port identification fields are 16 bits long in the TCP header.
Enter
Password
and confirm
Password
.
Click
Submit
.
To save your changes, click
Save and Restart
.
Dumping NMEA Sentence Information to the Router's TCP Server Port
To configure the TCP server port where you can send the NMEA sentences:
1.
2.
3.
4.
5.
Complete the steps under
GPS Server Configuration
.
To use the serial port for GPS, you must disable the serial port client/server. Go to
Configuration > Serial Port Settings
and uncheck
Enabled
.
Setup > Serial IP
Then, under
Local Configuration
, check
Serial Port Dump
.
Submit
.
To save your changes, click
Save and Restart
.
Sending GPS information to a remote server
The
Client Configuration
uploading GPS data.
allows the device to connect to a remote server using the IP and port information for
1.
2.
3.
4.
5.
6.
7.
8.
To allow the device to connect, go to
Setup > GPS Configuration > Client Configuration
.
Check
TCP/UDP Client
.
From the
Protocol
drop-down list, select the protocol of the client (
TCP or UDP
).
In the
Remote Host
field, type the IP address of the remote host.
In the
Port
, field type the port number of the remote host.
If your remote host requests a password, type that password in the to the server in response.
Password
field. The password is sent Click
Submit
.
To save your changes, click
Save and Restart
.
Configuring NMEA Sentences
To configure the time interval, additional prefix or ID information, and which NMEA sentences that can be sent:
1.
2.
Go to
Setup > GPS Configuration > NMEA Configuration
and in the
Interval
field, type the amount of time, in seconds, that passes before the NMEA information is sent. The default is
10
seconds. The range is
1
to
255
seconds.
You can further identify the router, also called a remote asset, that is collecting and sending the GPS information. To do so:
Add ID
: The ID is an unique remote asset identification string. The ID string can be any length up to 20 characters. The
&
and
$
are invalid characters. The ID must follow the standard NMEA sentence structure.
Refer to the Universal IP AT Commands Reference Guide for sentence structure.
To add more information to the beginning of the ID, in the Add ID Prefix field, type the information.
36 MultiConnect ® rCell 100 MTR-H6 User Guide
CONFIGURING YOUR DEVICE 3.
You can select which NMEA sentence types you want to send. Check any combination of the available options:
GGA, GSA, GSV, GLL, RMC,
and
VTG
.
SMTP Settings
The following table lists the configuration fields in the SMTP window.
Description Field SMTP Configuration
Enabled Server Port Email Username Password
Mail Log Settings
Entries to Keep Click to use the SMTP feature.
Enter the SMTP server address.
Enter the port number that the SMTP server uses.
Enter the sender email address. This address will be added as the sender email address to the sent emails.
Enter the name that can access the SMTP server.
Enter the password that can access the SMTP server.
Enter the desired number of mail log entries that are to be stored in the router. The range of values is
10
to
1000
. If you click
Submit
, this setting is not applied to the emails that are in progress or deferred. Note that logs are not saved on the device. Also, logs do not persist through power cycles.
Send a Test Email
Address To make sure that the SMTP is configured properly, enter a destination email address, then click
Send Test Email
.
Configuring the Serial Port
To configure the serial terminal connected to the RS-232 connector on the router:
1.
2.
3.
4.
5.
6.
7.
Go to
Setup > Serial IP Configuration > Serial Port Settings
, check
Enabled
.
From the default is
Baud Rate
drop-down list, select the baud-rate at which the serial terminal communicates. The
115200
.
From the
Flow Control
drop-down list, select the flow control for the serial port. The options are
RTS-CTS
. The default is
NONE
.
NONE
or From the
Parity
The default is drop-down list, select the parity for the serial port. The options are
NONE
.
NONE, EVEN,
or
ODD
.
To use the Modbus protocol as the protocol the serial devices use to communicate, check
Modbus Gateway
to check to the right of
Protocol
under
Enabled
.
IP Pipe NOTE:
You may have the TCP connection encrypted with TLS. Make sure and select
SSL/TLS
.
From the default is
Data Bits 8
.
drop-down list, select the data bits for the serial port. Data bit options are
7
or
8
. The From the
Stop Bits
default is 1.
drop-down list, select the stop bits for the serial port. The options are
1
or
2
. The MultiConnect ® rCell 100 MTR-H6 User Guide 37
CONFIGURING YOUR DEVICE
38
8.
9.
Click
Submit
.
To save your changes, click
Save and Restart
.
Configuring Device to Act as Client
You can set up the router to act as a client.
The TCP, UDP, SSL/TLS client feature enables the router to act as a proxy TCP, UDP, or SSL/TLS client to the serial terminal connected to the RS-232 port on the router. This helps the serial terminal access any TCP, UDP, or SSL/TLS server on the LAN/WAN allowing two-way traffic between the serial device and the remote server.
To use this function, you must first check or SSL/TLS client mode:
Enabled
under
Serial Port Settings
. To configure the IP Pipe in TCP, UDP,
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Go to
Setup > Serial-IP Configuration > Serial Port Settings > IP Pipe
group.
From the
Mode
drop-down list, select
CLIENT
.
From the
Protocol
drop-down list, select the desired protocol:
TCP
,
UDP
, or
SSL/TLS
.
In the
Server IP Address
field, enter the address of the far-end TCP, UDP, or SSL/TLS server.
In the
Server Port
field, enter the port value used by the far-end TCP, UDP, or SSL/TLS server.
If the primary server is unavailable, in the TCP, UDP, or SSL/TLS server.
Secondary IP Address
field, enter the address of the alternate If the primary server is unavailable, in the TCP, UDP, or SSL/TLS server.
Secondary Port
field, enter port number value of the alternate From the
Connection Activation
drop-down list, select a connection method. Options are:
ALWAYS-ON
. If you select this option, you cannot change the
Connection Termination
option.
DTR-ASSERT
. When the DTR signal is asserted, the connection is established.
CR
. Three carriage returns must be received before the TCP, UDP, or SSL/TLS connection is established to the remote server.
ON-DEMAND
. Set the connection as available on-demand.
From the are:
Connection Termination
drop-down list, select a disconnect method for the IP pipe. Options
ALWAYS-ON
.
TIMEOUT
. The IP pipe connection disconnects if the configured timer expires with no data sent or received. In the
Timeout
field, enter the desired number of seconds for this timeout.
SEQUENCE
. A sequence of received characters disconnects the IP pipe.
DTR-TOGGLE
. When the DTR control signal is toggled, the IP pipe disconnects.
In the
Buffer Timeout
full (in milliseconds).
field, enter the timeout after which data is sent to the network if the buffer is not In the
Buffer Size
field, enter the size of the buffer for reading data from the serial port and sending to the network (in bytes). Data is sent when the buffer is full.
Click
Submit
.
To save your changes, click
Save and Restart
.
To configure security settings:
1.
Make sure you select
SSL/TLS
under
Protocol
.
MultiConnect ® rCell 100 MTR-H6 User Guide
CONFIGURING YOUR DEVICE 2.
3.
4.
5.
6.
7.
8.
Under
Security Settings
, click the
Show
to the right.
By default, the
Use default cipher suite
is checked. If you accept this default, no other action is needed.
Uncheck this box, if you want to select specific TLS versions and Cipher Suites. These fields appear.
Select the
TLS version
. Check either
TLSv1.2
or
TLSv1.1
.
Check your preferred
Cipher Suite
from the following list: ECDHE-RSA-AES256-GCM-SHA384, ECDHE-RSA AES256-SHA, DHE-RSA-AES256-GCM-SHA384, AES256-SHA, ECDHE-RSA-AES128-GCM-SHA256, ECDHE RSA-AES128-SHA, DHE-RSA-AES128-GCM-SHA256, DHE-RSA-AES128-SHA, and/or AES128-SHA Click
Submit
.
To save your settings, click
Save and Restart
.
Configuring Device to Act as Server
You can set up the router to act as a server.
The TCP, UDP, SSL/TLS server feature enables a TCP, UDP, SSL/TLS client on the Ethernet network to connect to the remote serial terminal that is connected to the RS-232 port on the router. The router acts as a TCP, UDP, SSL/TLS server which allows two-way traffic between the TCP, UDP, SSL/TLS client and the remote terminal on the serial port.
To use this function, you must first check SSL/TLS server mode:
Enabled
under
Serial Port Settings
. To configure the IP Pipe in TCP, UDP,
1.
2.
3.
4.
5.
6.
7.
8.
9.
Go to In the In the
Setup > Serial-IP Configuration > Serial Port Settings > IP Pipe Mode
drop-down list, select From the
Protocol Buffer Timeout
full (in milliseconds).
SERVER
.
drop-down list, select the desired protocol:
TCP
, group.
UDP
, or
SSL/TLS
.
field, enter the timeout after which data is sent to the network if the buffer is not In the
Server Port
field, type the desired port value in the range
1
to
65535
.
In the
Buffer Size
field, enter the size of the buffer for reading data from the serial port and sending to the network (in bytes). Data is sent when the buffer is full.
From the are:
Connection Termination
drop-down list, select a disconnect method for the IP pipe. Options
ALWAYS-ON
.
TIMEOUT
. The IP pipe connection disconnects if the configured timer expires with no data sent or received. In the
Timeout
field, enter the desired number of seconds for this timeout.
SEQUENCE
. A sequence of received characters disconnects the IP pipe.
DTR-TOGGLE
. When the DTR control signal is toggled, the IP pipe disconnects.
Click
Submit
.
To save your changes, click
Save and Restart
.
To configure security settings:
1.
2.
3.
Make sure you select Under
SSL/TLS
under
Security Settings
By default, the , click the
Protocol
.
Show
to the right.
Use default cipher suite
is checked. If you accept this default, no other action is needed.
MultiConnect ® rCell 100 MTR-H6 User Guide 39
CONFIGURING YOUR DEVICE
40
4.
5.
6.
7.
8.
Uncheck this box, if you want to select specific TLS versions and Cipher Suites. These fields appear.
Select the
TLS version
. Check either
TLSv1.2
or
TLSv1.1
.
Check your preferred
Cipher Suite
from the following list: ECDHE-RSA-AES256-GCM-SHA384, ECDHE-RSA AES256-SHA, DHE-RSA-AES256-GCM-SHA384, AES256-SHA, ECDHE-RSA-AES128-GCM-SHA256, ECDHE RSA-AES128-SHA, DHE-RSA-AES128-GCM-SHA256, DHE-RSA-AES128-SHA, and/or AES128-SHA Click
Submit
.
To save your settings, click
Save and Restart
.
Adding Saved Networks
You can define, edit, and delete networks that your router supports. These networks can appear in your list of choices when configuring other items, such as tunnels. To setup networks:
1.
2.
Go to
Setup
>
Saved Networks
. A list of networks already saved appears.
Add, edit, or delete networks, as described in
.
and
Editing or Deleting an Existing
Adding Networks
To add a network:
1.
2.
3.
4.
5.
6.
Click
Add Network
.
In the
Name
field, type the name of the network.
In the
IP Address
field, type the IP address of the network.
In the
Subnet Mask
field, type the network mask.
Click
Finish
.
To save your changes, click
Save and Restart
.
Editing or Deleting an Existing Network
1.
2.
3.
4.
5.
To delete a network, click the
trash can
.
At the top of the pane, a message tells you the network is deleted. To undo the delete, click the link found in the message.
Undo
To edit a network, click Click
Finish
.
pencil icon
To save your changes, click . Change the IP address or subnet mask as desired.
Save and Restart
.
Note:
You cannot edit the network name and you cannot delete a network if it is used in another configuration.
Configuring SNMP
The device offers Simple Network Management Protocol (SNMP) which is used for collecting information from, and configuring network devices on an IP network.
You also have the option to configure SNMP traps which are alerts sent from SNMP-enabled devices to an SNMP agent or manager typically providing device status or condition information.
You can also access the
MIB
file which is a management information base. This file is a formal description of a set of network objects managed using the Simple Network Management Protocol (SNMP). The format of the
MIB
is defined as part of the SNMP. (All other
MIBs
are extensions of this basic management information base.) MultiConnect ® rCell 100 MTR-H6 User Guide
CONFIGURING YOUR DEVICE
Click
Download MIB
, to download the MIB file.
To configure SNMP:
1.
2.
3.
4.
Go to (either
Setup > SNMP Configuration
, check the
SNMP V1/V2C
and/or
SNMP V3
).
Enabled
box for each of the SNMP versions that apply Under
SNMP Server Configuration
, check
Enabled
to activate the SNMP server. Click
Submit
.
If needed, click
Add
under
Allowed IP Addresses
for
SNMP v1/v2c
.
Click
Add Server Configuration
.
a.
b.
c.
Make sure that For
i.
ii.
SNMP v1 Enabled
is checked.
Under
Version
, select from the drop-down either and
SNMP v2c
:
SNMP v1/v2c
or
SNMP v3
.
Enter the
Configuration Name
for your SNMP configuration.
Enter
Community String
requests.
which is a read-only string used to authenticate incoming SNMP
d.
For
SNMP v3
:
i.
ii.
Enter the selected
Authentication Protocol MD5
or
SHA1
from the drop-down, including for Authentication Protocol:
NONE, MD5
, or
SHA1
. If you Enter the
Security Name
v3 requests.
which is a username used to authenticate incoming SNMP Enter the
Authentication Password
, which is a password used to authenticate incoming SNMPv3 requests.
Confirm the password.
Enter the
Encryption Protocol
or
AES-128
. If you selected for SNMPv3 messages from the drop-down, including
DES or AES-128
for
Encryption Protocol
:
NONE, DES
Enter the
Encryption Password
.
Confirm the password.
5.
6.
7.
8.
9.
Click
Submit
.
The
SNMP Configuration
list displays your recently added SNMP Server Configuration. To edit the configuration, click the pencil icon under
Options
.
To delete an existing configuration, click the trash can icon under
Options
.
If finished, click
Submit
. Or continue to
SNMP Trap Destinations
and
Add Trap Destinations
.
To save your changes, click
Save and Restart
.
To configure SNMP Traps:
1.
2.
3.
4.
5.
6.
Go to
Setup > SNMP Configuration > SNMP Trap Configuration
traps on the device..
, check
Enabled
to enable sending SNMP The engine ID displays to the right of
Enabled
. Modify the engine ID or use the default value.
Click
Submit.
Click
Add Trap Destination
.
Make sure that
Enabled
box is checked.
Enter the
Destination Name.
MultiConnect ® rCell 100 MTR-H6 User Guide 41
CONFIGURING YOUR DEVICE 7.
8.
9.
Select from the drop-down the
Version
of SNMP (
SNMP v1/v2c
or
SNMP v3
).
For
SNMP v1
or
SNMP v2c
:
a.
b.
c.
d.
Enter the Enter the Click Click
Destination IP Address Community String Submit
.
Save and Restart
.
.
.
For
SNMPv3
:
a.
b.
c.
Enter the
Destination IP Address
Enter
Security Name
.
.
Enter the
Authentication Protocol
selected
MD5
or
SHA1
for from the drop-down, including
Authentication Protocol
:
NONE, MD5,
or
SHA1
. If you
i.
ii.
Enter the
Authentication Password
, which is a password used to authenticate incoming SNMPv3 requests.
Confirm the password.
d.
Enter the
Encryption Protocol AES-128
. If you selected
DES
or for SNMPv3 messages from the drop-down, including
AES-128
for Encryption Protocol:
NONE, DES
, or
i.
ii.
Enter the
Encryption Password
Confirm the password.
.
e.
f.
g.
The
SNMP Trap Destination
list displays your recently added SNMP Trap Destination. To edit the destination, click the pencil icon under
Options
.
To delete an existing destination, click the To save your changes, click To download the MIB file:
trash can Save and Restart
.
icon under
Options
.
1.
2.
Click
Download MIB
in the far right corner of the device display.
Download/save the file from your browser.
Unavailable Services in PPP-IP Passthrough and Serial Modem Modes
In both
PPP-IP Passthrough
and
Serial Modem
modes, many rCell services described in this document are non configurable and therefore do not appear in the device configuration menu. If you choose one of these modes, all sections between this and the previous note on this subject are not available.
42 MultiConnect ® rCell 100 MTR-H6 User Guide
SETTING UP WIRELESS FEATURES
Chapter 7 – Setting Up Wireless Features Setting Up Wi-Fi Access Point
If you ordered a device with Wi-Fi capability, your router can be configured as a wireless access point (AP). This allows Wi-Fi enabled devices to connect to the router using Wi-Fi. The Wi-Fi access point can have up to 8 clients at a time. To set up your router as an access point:
1.
2.
3.
4.
5.
6.
7.
8.
Go to
Wireless > Wi-Fi
to display the
Wi-Fi
window.
From the
Wi-Fi Mode
dropdown list, select
Access Point
.
To set the SSID (service set identifier) for the access point supported by your router, in the devices on a WLAN must use the same SSID in order to communicate with the access point.
SSID
field, type the name. The Wi-Fi devices look for this ID in order to join the wireless network. All wireless To specify the data rates supported, in the
Network Mode
drop-down list, select the desired option.
Possible values are B/G/N-Mixed, B/G-Mixed, B-Only, and N-Only.
From the available.
Channel
drop-down list, select the channel on which the router operates. Channels 1-11 are In the
Beacon Interval
field, enter the period of time, in milliseconds, when the access point sends a beacon packet. Beacons help synchronize a wireless network. For most applications, the default value of 100 provides good performance.
In the
DTIM Interval
field, enter how often a beacon frame includes a Delivery Traffic Indication Message, and this number is included in each beacon frame. It is generated within the periodic beacon at a frequency specified by the DTIM Interval. A delivery traffic indication message is a kind of traffic indication message (TIM) which informs the clients about the presence of buffered multicast/broadcast data on the access point. The default value of 1 provides good performance for most applications. You might want to increase this value when using battery powered Wi-Fi devices, which can sleep (at reduced power consumption) during the longer DTIM interval period. You must balance the power savings from increasing the DTIM interval against possible reduced communication throughput.
In the
RTS Threshold
field, type the frame size at which the AP transmissions must use the RTS/CTS protocol. This is often used to solve hidden node problems. Using a small value causes RTS packets to be sent more often, consuming more of the available bandwidth. However, the more RTS packets that are sent, the quicker the system can recover from interference or collisions.
For related information, see
.
and
Viewing Information About Wi-Fi Clients Using Your Wireless
Setting Security Options
You can specify the security protocol that the router uses to secure the communications from the router to the connected devices.
1.
From the
Mode
drop-down list, select the security protocol you want to use. Options include: None
WEP
: Use Wired Equivalent Privacy protocol to allow a group of devices on the network to exchange coded messages.
WPA-PSK
: Use Wi-Fi protected access to secure data exchanged on your network.
WPA2-PSK
: Use Wi-Fi protected access version 2 to secure data exchanged on your network.
WPA/WPA2-PSK
: Use Wi-Fi protected access version 1 and 2 to secure data exchanged on your network.
MultiConnect ® rCell 100 MTR-H6 User Guide 43
SETTING UP WIRELESS FEATURES 2.
3.
4.
5.
To select
WEP
mode:
a.
b.
c.
From the
digits
or
Encryption
drop-down list, select the encryption to be used. Choose from
128 bit 26 hex digits
.
64 bit 10 hex
To generate a key from a phrase, in the
Passphrase
field, type a phrase. Click To manually enter keys, type the keys in the Key 1, Key 2, Key 3 or Key 4 fields.
To select
WPA-PSK, WPA2-PSK
or
WPA-PSK/WPA2-PSK
modes:
Generate
.
a.
b.
c.
Select the WPA Algorithm from the drop-down list. Choose from In the
Shared Key
When done, click
Submit
.
To save your changes, click
Save and Restart
.
TKIP, AES
or
TKIP+AES
.
field, type the key that is used for encrypting and decrypting the data.
To remove the mask characters, thereby making the Shared Key visible, check
Unmask
.
Viewing Information About Wi-Fi Clients Using Your Wireless Network
To view information about clients (such as computers, tablets, and smart phones) that are connected to your router's Wi-Fi access point:
1.
2.
The Clients group displays a list of clients using your router's Wi-Fi.
To update the list, click
Refresh
.
Setting Up Wi-Fi as WAN
To setup the router's Wi-Fi as WAN:
1.
2.
3.
4.
5.
Go to
Wireless > Wi-Fi
to display the
Wi-Fi
window.
From the
Wi-Fi Mode
drop down list, select
Wi-Fi as WAN
.
Searching for available Wi-Fi networks starts automatically. After 30 to 60 seconds, a list of detected Wi Fi Access Points appears in the
Available Networks
group.
In the
Available Wi-Fi Networks Saved Network
group, click the SSID for the Wi-Fi access point you want to use. The window opens. Here are the available fields to enter information:
Add Network Name SSID Security Mode: None, WEP, WPA, WPA-PSK, WPA-2
, or
WPA-2-PSK Username Password Unmask (Check, Uncheck) WPA Algorithm: TKIP, +AES, TKIP
, or
AES Shared Key Key Index: 0 - 3 Network Key IEEE 802.1x
Review the information, enter any required security info, then click added appears in the
Saved Wi-Fi Networks
group.
Finish
. The Wi-Fi access point you just 44 MultiConnect ® rCell 100 MTR-H6 User Guide
SETTING UP WIRELESS FEATURES 6.
7.
If desired, add additional access points to the list of Saved Networks. The router tries to connect to Saved Networks in the order they are listed. You can change the order by clicking the up or down arrows shown under
Options
.
When finished, click
Save and Restart
. The Status field displays "Connected" if you have successfully connected to the Wi-Fi access point.
Note: You cannot edit the network name and you cannot delete a network if it is used in another configuration.
Setting up Bluetooth
The Bluetooth-IP feature allows a data connection between a remote TCP/UDP client or server and a local Bluetooth device. To set up the Bluetooth connection:
1.
2.
3.
4.
5.
6.
7.
8.
Go to
Wireless > Bluetooth
To enable the feature, check
Enabled
. Click
Submit
.
Confirm that the far-end Bluetooth device is powered on and waiting for a connection.
In the
Available Devices
group, click
Refresh
. A list of detected Bluetooth devices appears.
Click the name of the Bluetooth device that you want to use. The name and MAC address appear under the selected device.
To add a device, click
Add Device
and enter the device name and the
MAC address
.
Click
Finish
.
To save your changes, click
Save and Restart
.
Note: You cannot edit the network name and you cannot delete a network if it is used in another configuration.
IP Pipe in TCP/UDP Server mode
1.
2.
3.
4.
In the
IP Pipe
group, from the
Mode
drop-down list, select
SERVER
.
From the
Protocol
drop-down list, select the desired protocol, either
TCP
or
UDP
.
In the
Server Port
field, type the desired port value in the range
1
to
65535
.
From the are:
Connection Termination
drop-down list, select a disconnect method for the IP pipe. Options
Always Connected Sequence:
A sequence of characters received from the Bluetooth side used to disconnect the IP pipe.
Timeout:
received.
The IP pipe connection disconnects if the configured timer expires with no data sent or
To configure the IP Pipe in TCP/UDP Client mode
:
1.
2.
3.
In the
IP Pipe
group, from the
Mode
drop down list, select
CLIENT
.
From the
Protocol
drop-down list, select the desired protocol, either
TCP
or
UDP
.
In the
Server IP Address
field, type the address of the far-end TCP-UDP server.
4.
5.
In the
Server Port
field, type the port value used by the far-end TCP/UDP Server.
In case the primary server is unavailable, in the
Secondary IP Address
field and in the
Secondary Port
field, type the IP address and port number, respectively, of the alternate TCP/UDP server.
6.
From the
Always On Connection Activation
drop-down list, select a connection method. Options are: MultiConnect ® rCell 100 MTR-H6 User Guide 45
SETTING UP WIRELESS FEATURES 7.
8.
9.
On-Demand CR:
Three carriage returns must be received from the Bluetooth side before TCP/UDP connection is established to the remote server.
From the
Connection Termination
drop-down list select a disconnect method for the IP pipe. Options are:
Always On: Sequence:
A sequence of characters received from the Bluetooth side used to disconnect the IP pipe
Timeout:
The IP pipe connection disconnects if the configured timer expires with no data sent or received Click
Submit
.
To save your changes, click
Save and Restart
.
The router immediately connects to the local Bluetooth device. If successful the displays
Connected
. If
IP Pipe
is configured for
SERVER Status
field , the IP connection is initiated by the far-end TCP/UDP client.
If
Mode
is set to
Client
, the router initiates connections for the far-end TCP/UDP server based on the configured
Connection Activation
conditions are met.
To configure security settings
:
1.
2.
3.
4.
5.
6.
7.
8.
Make sure you select
SSL/TLS
under
Protocol
.
Under
Security Settings
, click the
Show
to the right.
By default, the
Use default cipher suite
is checked. If you accept this default, no other action is needed.
Uncheck this box, if you want to select specific TLS versions and Cipher Suites. These fields appear.
Select the
TLS version
. Check either
TLSv1.2
or
TLSv1.1
.
Check your preferred
Cipher Suite
from the following list: ECDHE-RSA-AES256-GCM-SHA384, ECDHE-RSA AES256-SHA, DHE-RSA-AES256-GCM-SHA384, AES256-SHA, ECDHE-RSA-AES128-GCM-SHA256, ECDHE RSA-AES128-SHA, DHE-RSA-AES128-GCM-SHA256, DHE-RSA-AES128-SHA, and/or AES128-SHA Click
Submit
.
To save your settings, click
Save and Restart
.
46 MultiConnect ® rCell 100 MTR-H6 User Guide
SETTING UP THE FIREWALL
Chapter 8 – Setting Up the Firewall Defining firewall rules
The router's firewall enforces a set of rules that determine how incoming and outgoing packets are handled. By default, all outbound traffic originating from the LAN is allowed to pass through the firewall, and all inbound traffic originating from external networks is dropped. This effectively creates a protective barrier between the LAN and all other networks. For additional information, see:
Adding Port Forwarding Rules Adding Input Filter Rules
Inbound Forwarding Rule
Adding Port Forwarding Rules
For a device within the LAN to be visible from the internet or from an outside network, create a forwarding rule to allow incoming packets to reach the device.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Go to
Firewall > Settings
to display the
Firewall
window.
In the
Port Forwarding
group, click
Add Rule
.
In the
Inbound Forwarding Rule
dialog box, enter a name for the rule and optionally, a description.
In the second
Inbound Forwarding Rule
be forwarded. Common ports are listed in the field's attached drop-down list and are exposed once you enter a character. Type
ANY
dialog box, in the to forward all ports.
External WAN Port(s)
field, type the port(s) to In the
Destination LAN IP
field, type the IP address of the device that packets will be forwarded to.
In the
Destination LAN Port(s)
field, type the port to which packets are translated. If there is a range of ports, the ending port is automatically set. The Destination LAN ending port is based on the Destination LAN starting port and the range provided in the
External WAN Port(s)
field.
From the
TCP/UDP
,
Protocol TCP
, drop-down list, select the protocol of the messages that can be forwarded. Select from
UDP
, or
ANY
.
In the
External Source IP
field, enter the IP address of the source of the messages.
In the
External Source Ports
field, enter the port range for the source of the messages.
In the
Mask
field, enter the external source subnet mask.
Check
Enable NAT Loopback
address.
if you want to redirect LAN packets destined for the WAN's public IP Click
Submit
.
To save your changes, click
Save and Restart
.
A default filter allowing forwarded packets through the firewall is automatically created.
Input Filter Rules
To add an input filter rule to your firewall:
1.
2.
Go to
Firewall > Settings
to display the
Firewall
window.
In the
Input Filter Rules
group, click
Add Rule
.
MultiConnect ® rCell 100 MTR-H6 User Guide 47
SETTING UP THE FIREWALL
48
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
In the
FilterRule
dialog box, enter a name for the rule and optionally, a description.
In the
Destination IP
field, enter the destination IP address that applies to this rule.
In the
Destination Port
field, enter the destination port that applies to this rule. If there is a range of ports, the ending port is automatically set.
In the
Destination Mask
field, enter the subnet mask of the destination that applies to this rules.
In the
Destination Interface
field, select the interface used by the destination that applies to this rule from the drop-down menu. Select from
ANY, LAN, WAN, CELLULAR,
or
WI-FI WAN
.
In the
Source IP
field, enter the source IP address that applies to this rule.
In the
Source Ports
field, enter the source port range that applies to this rule.
In the
Source Mask
field, enter source subnet mask that applies to this rule.
In the
Source MAC
field, enter the source MAC address for the device that applies to this rule.
In the
Source Interface
menu. Select from field, select the source interface that applies to this rule from the drop-down
ANY, LAN, WAN, CELLULAR,
or
WI-FI WAN
.
In the
Protocol TCP/UDP
,
TCP
, drop-down list, select the protocol of the messages that apply to this rule. Select from
UDP
, or
ANY
.
In the
Chain
field, select the grouping based on the type of traffic affected by the rule from the drop down menu. Select from
INPUT, FORWARD,
or
OUTPUT
.
In the
Target
Choose from field, select the desired action of the firewall based on this rule from the drop-down menu.
ACCEPT, REJECT, DROP,
or
LOG
.
Click
Submit
.
To save your changes, click
Save and Restart
.
Output Filter Rules
To prevent a device within the LAN from communicating with a device in an external network, you must establish a firewall rule to drop packets destined to the external device.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Go to
Firewall > Settings
to display the
Firewall
window.
Click
Add Rule
in the
Output Filter Rules
section.
Enter a name for the rule and optionally, a description.
In the Type
Destination IP ANY
field, type the IP address of the device or network that packets are to be sent to.
if the destination address does not matter.
In the
Destination Port
field, type the port for which that the packets are destined. Common destination ports are listed in the Destination Port field's attached drop down list. Type
ANY
if the destination port does not matter.
In the
Destination Mask
field, type the network mask of the destination network.
In the
Destination Interface
field, select the interface used by the destination that applies to this rule from the drop-down menu. Select from
ANY, LAN, WAN, CELLULAR,
or
WI-FI WAN
.
In the
ANY Source IP
field, type the IP address of the device or network that the traffic originates from. Type if the source address does not matter.
In the
Source Port
not matter.
field, type the port that is the origin of the traffic. Type
ANY
if the source port does In the
Source Mask
field, type a network mask for the origin of the traffic.
In the
SourceMAC
field, enter the source MAC address for the device that applies to this rule.
In the
SourceInterface
menu. Select from field, select the source interface that applies to this rule from the drop-down
ANY, LAN, WAN, CELLULAR,
or
WI-FI WAN
.
MultiConnect ® rCell 100 MTR-H6 User Guide
SETTING UP THE FIREWALL 13.
14.
15.
16.
17.
From the from
Protocol TCP/UDP
, drop-down list, select the protocol of the messages that apply to this rule. Choose
TCP
,
UDP
, or
ANY
.
In the
Chain
field, select the grouping based on the type of traffic affected by the rule from the drop down menu. Select from
INPUT, FORWARD,
or
OUTPUT
.
In the
Target
Choose from field, select the desired action of the firewall based on this rule from the drop-down menu.
ACCEPT, REJECT, DROP,
or
LOG
.
Click
Submit
.
To save your changes, click
Save and Restart
.
Advanced Settings
The
Firewall's Advanced Settings
mode lets you manipulate
DNAT, SNAT
, and manipulate the destination address and port of a packet; similarly
SNAT Filter
rules directly.
DNAT
rules can rules can manipulate the source address and port of a packet.
Filter rules apply an as a
Forwarding ACCEPT, REJECT, DROP
, or rule will be associated under
LOG
action to a packet. A
Normal Settings
for
DNAT or SNAT Port Forwarding/NAT
rule with the same name rules.
Prerouting Rule
Add a DNAT rule
To add prerouting or DNAT rule to your firewall:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
Go to
Firewall > Settings
to display the
Firewall
window.
In the
Prerouting Rules
group, click
Add DNAT Rule
.
In the
FilterRule
dialog box, enter a name for the rule and optionally, a description.
In the
Destination IP
field, enter the destination IP address that applies to this rule.
In the
Destination Port
field, enter the destination port that applies to this rule. If there is a range of ports, the ending port is automatically set.
In the
Destination Mask
field, enter the subnet mask of the destination that applies to this rules.
In the
Destination Interface
field, select the interface used by the destination that applies to this rule from the drop-down menu. Select from
ANY, LAN, WAN, CELLULAR,
or
WI-FI WAN
.
In the
Source IP
field, enter the source IP address that applies to this rule.
In the
Source Port
field, enter the source port that applies to this rule.
In the
SourceMask
field, enter source subnet mask that applies to this rule.
In the
SourceMAC
field, enter the source MAC address for the device that applies to this rule.
In the
SourceInterface
menu. Select from field, select the source interface that applies to this rule from the drop-down
ANY, LAN, WAN, CELLULAR,
or
WI-FI WAN
.
In the
Protocol TCP/UDP
,
TCP
, drop-down list, select the protocol of the messages that apply to this rule. Select from
UDP
, or
ANY
.
In the
NAT IP
field, enter the public IP address for the Network Address Translation.
In the
NAT Port
field, enter the port used publicly for the Network Address Translation.
Check Enable NAT Loopback if you want to redirect LAN packets destined for the WAN's public IP address.
MultiConnect ® rCell 100 MTR-H6 User Guide 49
SETTING UP THE FIREWALL
50
17.
18.
Click
Submit
.
To save your changes, click
Save and Restart
.
Postrouting Rule
Add a SNAT rule
To add postrouting or SNAT rule to your firewall:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
Go to
Firewall > Settings
to display the
Firewall
window.
In the
Postrouting Rules
group, click
Add SNAT Rule
.
In the
Postrouting Rule
dialog box, enter a name for the rule and optionally, a description.
In the
Destination IP
field, enter the destination IP address that applies to this rule.
In the
Destination Port
field, enter the destination port that applies to this rule. If there is a range of ports, the ending port is automatically set.
In the
Destination Mask
field, enter the subnet mask of the destination that applies to this rules.
In the
Destination Interface
field, select the interface used by the destination that applies to this rule from the drop-down menu. Select from
ANY, LAN, WAN, CELLULAR,
or
WI-FI WAN
.
In the
Source IP
field, enter the source IP address that applies to this rule.
In the
Source Port
field, enter the source port that applies to this rule.
In the
SourceMask
field, enter source subnet mask that applies to this rule.
In the
SourceMAC
field, enter the source MAC address for the device that applies to this rule.
In the
SourceInterface
menu. Select from field, select the source interface that applies to this rule from the drop-down
ANY, LAN, WAN, CELLULAR,
or
WI-FI WAN
.
In the
Protocol TCP/UDP
,
TCP
, drop-down list, select the protocol of the messages that apply to this rule. Select from
UDP
, or
ANY
.
In the
NAT IP
field, enter the public IP address for the Network Address Translation.
In the
Target
Choose from field, select the desired action of the firewall based on this rule from the drop-down menu.
SNAT
or
MASQUERADE
.
In the
NAT Port
field, enter the port used publicly for the Network Address Translation.
Click
Submit
.
To save your changes, click
Save and Restart
.
Trusted IP
Trusted IP is a separate firewall configuration that allows users to create whitelists (which are allowed or trusted IPs) or black lists (which are blocked or unwanted IPs). You can add, edit, and delete IP addresses as needed.
If you select
Black List
as
White List
as
Trusted IP Mode Trusted IP Mode
and you do not set any IP range, no traffic will be allowed. If you select and you do not set any IP range, all traffic will be allowed.
To set up a Trusted IP range:
1.
2.
3.
Go to
Firewall > Trusted IP
.
Check the
Enabled
box to turn on Trusted IP.
Select the behavior of each list and its consequences based on your specific configuration. For example, if you select
White List Trusted IP Mode
as from the drop-down, either
Trusted IP Mode White List
, you should include the router or
Black List IP Address Range
. (
NOTE
or : Be aware of the
IP Address
and
Subnet Mask
to maintain your local router LAN access.) MultiConnect ® rCell 100 MTR-H6 User Guide
SETTING UP THE FIREWALL 4.
5.
a.
b.
c.
To add IP addresses, click
Add IP Range
in the upper right corner.
Under the
Add IP Range
, enter or select the following parameters:
Name
Mode from drop-down, either
Subnet
or
IP Range
.
For
Subnet
:
d.
i.
ii.
IP Address Subnet Mask
For
IP Range
:
e.
f.
g.
i.
ii.
Destination Port Protocol
Click
IP Address Start IP Address End Finish
.
(default:
ANY
) from drop-down including
ANY, TCP/UDP, TCP
, or
UDP 6.
7.
8.
9.
10.
The system displays your recently added and existing IP ranges in a list. The list includes the relevant details. You may edit any IP ranges by clicking on the pencil icon under
Options
.
You may delete any IP ranges by clicking on the trash can icon under
Options
.
If you want to revert back to default settings (where click the
Reset to Default Trusted IP
button in the lower right corner is disabled and all IP ranges are removed), Click
Submit
.
To save your changes, click
Save and Restart
.
Setting up Static Routes
To set up a manually configured mapping of an IP address to a next-hop destination for data packets:
1.
2.
3.
4.
5.
6.
7.
8.
Go to
Firewall > Static Routes
.
In the
Static Routes
window, click
Add Route
.
In the
Name
field of the
Add Route
dialog box, type the name of the route.
In the
IP Address
field, type the remote network IP address of the remote location.
In the
IP Mask
field, type the network mask that is assigned on the remote location.
In the
Gateway
field, type the IP address of the routing device that supports the remote IP Network.
Click
Finish
.
To save your changes, click
Save and Restart
.
MultiConnect ® rCell 100 MTR-H6 User Guide 51
SETTING UP CELLULAR FEATURES
Chapter 9 – Setting Up Cellular Features Configuring Cellular
To configure how cellular is used on your device:
1.
2.
3.
4.
5.
On the Web Management interface, go to
Configuration Setup
.
Cellular > Cellular Configuration
to display the window. If you choose IPv6 Passthrough mode, you must select
Cellular Administration > Initial
Check
Enabled
.
Check and change the Cellular Configuration fields as desired. For field descriptions, see
.
Click
Submit
.
To save your changes, click
Save and Restart
.
Cellular Configuration Fields
Field General Configuration
Enabled Dial-on-Demand 1 Diversity Connect Timeout Dialing Max Retries
Description
Allows the device to establish a cellular connection (Cellular WAN).
Enables the Dial-on-Demand feature. If enabled, the device brings up and maintains a cellular connection while network activity on the LAN requires WAN access. The device brings down the cellular connection when outgoing network traffic ceases for the given Idle Timeout duration. Enable this feature when Wakeup-on-Call is enabled to allow the device to "sleep" after it has been "woken up." See
Configuring Wakeup-on-Call
for more information.
Allows the use of two antennas to increase receive signal quality. Not all models support diversity. If diversity is enabled, connect a second cellular antenna to the AUX port on the device. Otherwise, the cellular performance of the device may degrade.
The time (in seconds) that the device waits before it deems that the connection attempt has failed. The value used is the amount of time that elapses between each dialing retry.
Number of dialing retries allowed; the default is zero, which means an infinite number is allowed.
Modem Configuration
Dial Number Connect String Dial Prefix The modem dial string is:
*99***1#
for GSM/GPRS/non-Verizon LTE devices The modem response to initiate a PPP connection, usually
CONNECT
.
The modem AT command that initiates a PPP connection, usually
ATD
.
ATDT
or 52 MultiConnect ® rCell 100 MTR-H6 User Guide
SETTING UP CELLULAR FEATURES Field
SIM Pin
Description
The pin used to unlock the SIM for use (only required if the SIM is locked).
This does not apply to CDMA radios.
APN Init String# The Access Point Name assigned by the wireless service provider (carrier specific).
Optional fields to apply additional AT commands that execute just before every PPP connection attempt. Use these fields to expand functionality and to troubleshoot.
Authentication
Authentication Type Username The type of authentication to use when establishing a PPP connection:
NONE, PAP, CHAP, or PAP-CHAP
(either). Authentication may not be required by the cellular service provider.
Name of the user that the remote PPP peer uses to authenticate.
Password
Keep Alive 1
Password that the remote PPP peer uses to authenticate.
Used to periodically check if the cellular link is up; if not, the device tries to establish the link.
ICMP/TCP Check 1
An active check that provides the most reliable and reactive diagnosis of the cellular link, but requires sending data through the cellular link.
Enabled 1 Enables the Active Keep Alive check. Depending on the plan type and data usage, this may result in additional data charges.
Keep Alive Type 1 Interval 1 Hostname 1 TCP Port 1 ICMP Count 1 Protocol type for active keep alive, either
TCP
or
ICMP
.
ICMP
pings the designated host at the specified interval.
TCP
tries to make a connection to the designated host at the interval specified.
Time in seconds between active checking of the cellular link.
Host name or IP address for the keep alive check.
periodically TCP port number to connect with the TCP server (only visible when
Alive Type TCP
is selected).
Keep
Number of sequential, unsuccessful ping attempts to the specified host to declare that the link needs to be re-established (only visible when
Keep Alive Type ICMP
is selected).
Data Receive Monitor
A passive check that observes the absence of packets received over a given amount of time. This check cannot reliably determine if the link is down; no network traffic may cause the monitor to signal to shutdown and re-establish the cellular link even though the link was in a good state.
Enabled Enable or disable the passive monitoring of the cellular link.
Window The amount of time that can pass without receiving network traffic before the cellular link is torn down and re-established.
1
If you choose
PPP-IP Passthrough
and
Serial Modem
mode, this field is not available.
MultiConnect ® rCell 100 MTR-H6 User Guide 53
SETTING UP CELLULAR FEATURES
Unavailable Services in PPP-IP Passthrough and Serial Modem Modes
In both
PPP-IP Passthrough
and
Serial Modem
modes, many rCell services described in this document are non configurable and therefore do not appear in the device configuration menu. If you choose one of these modes, all sections between this and the next note on this subject are not available.
Configuring Wake Up On Call
This feature allows the router to wake up and initiate a cellular connection when there is an incoming call, SMS, or LAN activity.
1.
2.
3.
4.
5.
Go to
Cellular > Wake Up On Call
Check the Click
Wake Up On Call
box.
to display the configurations.
Select a Wake Up setting. For wakeup methods, see
Submit
.
To save your changes, click
Save and Restart
.
Wake Up On Call Method Settings
.
Note:
See the This feature only defines when the device brings up its cellular link, not when the device takes it down.
Dial on Demand
option on the
Cellular Configuration
page at
Cellular > Cellular Configuration
to configure the criteria for bringing the cellular link down.
Wake Up On Call Method Settings
The triggers that wake up the router to re-establish the cellular link are: On Ring: Any incoming call will bring up the cellular link.
Enabled
: Check to allow any incoming call to wake up the router.
Message
: The expected response from the integrated cellular modem to an incoming call.
On Caller ID: Only incoming calls in the caller ID list will bring up the cellular link.
Enabled
: Check to allow a specific caller to wake up the router.
Caller ID
: Field to specify a caller ID. Enter the ID then click ID trigger list.
Add
to add the caller to the approved caller On SMS (not available if you enabled SMS through
SMS > General Configuration
): Only specific SMS messages will bring up the cellular link.
Enabled
: Check to allow specific SMS messages to wake up the router.
Message
: Field to specify the SMS message contents. Click SMS trigger list.
Add
to add the SMS message to the approved For Wake-Up-On-Call field descriptions, see
Wake Up On Call General Configurations .
Wake Up On Call General Configurations
Field
Wake Up on Call check box
Description
Enables the Wake Up On Call feature.
54 MultiConnect ® rCell 100 MTR-H6 User Guide
SETTING UP CELLULAR FEATURES Field
Dial On Demand LAN Time Delay Acknowledgment String to Caller Init String Number
Description
When checked, the router allows network activity on the LAN that needs WAN access to trigger the Wake Up and establish the cellular link. If this configuration is not checked, the router will only establish a cellular connection when the selected Wake Up method is triggered via incoming call, caller ID, and/or short message service (SMS).
Time that passes between a receiving call and initiating the Wake Up On Call connection.
String used to acknowledge to the delivering SMSC (short message service center) the receipt of an SMS.
Router initialization strings specific to the integrated cellular modem required for the Wake Up On Call feature.
Using Telnet to Communicate with the Cellular Radio
Your router comes with an integrated cellular radio. You can use this cellular radio directly without using any router functions. To do so, you must use re-director software on your computer. This software creates a virtual serial port that allows your computer to communicate with the integrated cellular radio over IP using telnet. To communicate directly with the cellular modem:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
From the Web Management interface, go to
Cellular > Telnet Radio Access
.
Check
Enabled
.
To enable raw mode, check without any processing.
Raw
. The program transfers data between the computer and cellular modem To enable the Auto Dialout Login feature, check the re-director software on your computer to communicate to the cellular modem integrated on the router.
Login
. The Auto Dialout port is the Telnet port used by In the
Port
field, enter the serial Auto Dialout port number. The default is
5000
.
In the
Inactivity
field, enter the time in seconds that the auto dialout session remains active before becoming inactive.
To enable the EIA standard signal characteristics (time and duration) used between different electronic devices, check
Handle EIA Signal
.
In the
Telnet TCP Keep Alive
section of the window, in the
Time
field, enter the time in seconds that the device waits before it probes the Telnet connection for the first time. The default is
7200
(seconds).
In the is
75 Interval
(seconds).
field, enter the time interval in seconds that the device waits between probes. The default In the
Probes
field, enter the number of probes that the device makes. The default is
9
.
Click
Submit
.
To save your changes, click
Save and Restart
.
MultiConnect ® rCell 100 MTR-H6 User Guide 55
SETTING UP CELLULAR FEATURES
56
Radio Status
Field Module Information
IMEI IMSI Manufacturer Model Hardware Revision MDN (Phone Number) MSID
Description
International Mobile Station Equipment Identifier International Mobile Subscriber Identifier Company that developed the cellular module Cellular module model number Module's hardware revision Mobile Directory Number. In some SIM/carriers, the value may not be present and therefore not displayed.
Mobile Station ID. Some SIM/carriers do not contain this value and therefore the value is not displayed.
Module's firmware version Firmware Version
Service Information
Home Network Current Network RSSI Service Roaming Cellular service provider associated with the module's data account Current cellular service operator (Not available for C2 or EV3 models) Received Signal Strength Indication Cellular service connection type Indicates whether or not the current service is provided by the Home Network carrier
Update Options
MDN (Phone Number) Update the cellular module's phone number. This number is updated only on the device. The MDN that the carrier has associated with this device does not change.
Telit Radio Firmware Upgrade
H5 and H6 only
The update of Telit radio module firmware supports full firmware files and upgrade of H5 and H6 models. Refer to your product model number on the product label usually found on the bottom or back of your device or also at the top of the page of the device UI.
There are two methods for updating the cellular firmware offered: 1) Upgrading using DeviceHQ ® using the device UI only.
and 2) Upgrading
Upgrading Cellular Firmware Using DeviceHQ (Remote Management)
DeviceHQ can manage the Telit Firmware upgrade to your device when annex-client checks in.
first enable and properly configure Remote Management in the device UI (refer to
NOTE:
You must
1.
Open
DeviceHQ
.
MultiConnect ® rCell 100 MTR-H6 User Guide
SETTING UP CELLULAR FEATURES 2.
3.
4.
5.
Select
Device > Your Device Name > Schedule > Upgrade Radio Firmware
.
DeviceHQ
provides a list of eligible Telit module firmware that a particular device can queue for download and install. Select the appropriate firmware.
The device checks in, downloads the firmware, automatically verifies the MD5 sum of the firmware to check the integrity of the upgrade file, and applies it to the modem module.
Note:
Allow at least 10 minutes after the device has downloaded the firmware file before taking any action. The system should reboot on its own after a successful download. Otherwise, after 10 minutes, you may reboot the device manually.
Once you have refreshed or the device checks in again, verify that the cellular radio firmware has been updated in DeviceHQ.
In the device UI, you can also check that the cellular radio firmware has been updated. Refer to the
Firmware
on the
Telit Radio Firmware Upgrade
page (see step 1 of
Current Radio Upgrading Cellular Firmware Using UI only
) or also see the firmware version on the
Radio Status
page under
Cellular
.
Upgrading Cellular Firmware using UI only
You can also use the device UI to upgrade your Telit Firmware. You must first obtain the appropriate binary upgrade file for the cellular radio in your device.
NOTE
: If you use the firmware upgrade via Cellular using the UI and you get a timeout failure, first try to boost the signal strength and attempt it again. Otherwise, update via an Ethernet connection or use
DeviceHQ
.
1.
2.
3.
4.
5.
6.
Open the
Telit Radio Firmware Upgrade
page on the device. The page is not available through the standard UI. Enter the IP address/URL manually:
https://
your device IP address is the default address unless you changed it).
Find the upgrade zip file in your product page under
Downloads
on www.multitech.com
. (The file name starts with
stream
.) Download the zip file from the website and save it on your local computer. Extract the binary upgrade file and MD5 file.
Enter the MD5 Check Sum or hash under
File MD5
.
Browse for the file and select it.
(usually Click
Start Upgrade
. The system should reboot automatically after a successful download. Otherwise, after 10 minutes, you may reboot the device manually.
Check that the cellular radio firmware has been updated. Refer to the
Current Radio Firmware
on the
Telit Radio Firmware Upgrade
the firmware version on the page (see step 1 of
Radio Status Upgrading Cellular Firmware Using UI only
page under
Cellular
.
) or also see MultiConnect ® rCell 100 MTR-H6 User Guide 57
CONFIGURING SMS
Chapter 10 – Configuring SMS Configuring SMS
This function is not available if you enable SMS through service (SMS) via the Web Management interface or API:
Cellular > Wake Up On Call
. To enable short message
1.
2.
3.
4.
5.
6.
7.
8.
From the Web Management interface, go to
SMS > SMS Configuration > General
.
Check
Enabled
.
In the
Sent SMS to Keep
history.
field, enter the total number of sent SMS messages to keep in the device's In the
Received SMS to Keep
device's history.
field, enter the total number of received SMS messages to keep in the In the
Resend Failed SMS
to send.
field, enter the total number of resend attempts for SMS messages that failed Set messages to keep and resend options.
Click
Submit.
To save your changes, click
Save and Restart
For field descriptions see
.
SMS Field Descriptions
Field
Enabled Sent SMS to Keep Received SMS to Keep Resend Failed SMS
Description
Enables the SMS utilities required to send SMS via API and the Web Management interface.
The total number of sent SMS messages to keep in the device's history.
The total number of received SMS messages to keep in the device's history.
The total number of resend attempts for SMS messages that failed to send.
SMS Commands
SMS commands
are disabled by default. To enable these available commands (for status and debugging purposes) and set security filters:
1.
2.
Go to
SMS > SMS Configuration > SMS Commands
, check the SMS commands you wish to enable. Refer to the table of
for details on available commands.
Check the security filters, you wish to use (can be one or both):
Password:
If enabled, SMS commands will require
123456 #serial
where 123456 is your password.
p password
in the syntax. For example:
p
Use the MEID).
default password
(last six digits of the radio's IMEI or last six digits of the Or click on
Use custom password
and enter your own password.
You can also toggle the eye icon to make the password visible or hidden.
58 MultiConnect ® rCell 100 MTR-H6 User Guide
CONFIGURING SMS Whitelist
: If enabled, SMS commands can only be received from a number in the whitelist (you must enter a phone number).
Enter the phone number and click
Add Number
.
Note
: Due to differences between service providers, for every US number you add to the
Whitelist
other using , create two separate entries: 1) one using the
1 + phone number
.
phone number
and 2) the
3.
4.
5.
Refer to the Click
Submit
.
Required SMS Command Format
To save your changes, click
Save and Restart
.
field to see the format based on your chosen settings.
Here is an example SMS Command (#serial – Server mode): Serial-IP Port Status: Mode:
Server
Protocol: SSL/TLS Port: 3000 TX Bytes: 1234567 RX Bytes: 123456789 DCD Status: ON 2016-11-20 19:22 The response message to all SMS commands includes a time stamp. The time stamp format is
HH:MM
.
YYYY-MM-DD
The system adds the time stamp to the existing commands at the end of the SMS message. In case the message exceeds the 160 character limit, the device information and the occurred event are not truncated. Only the time stamp is lost.
SMS Command Descriptions
The following table describes available SMS Commands under
SMS Configuration Commands
. All SMS Commands are disabled by default. Check to enable.
>
SMS Commands
>
Enabled SMS Command
#reboot #checkin #rm
Description
reboots the device checks in to DeviceHQ enable or disable remote management using DeviceHQ (You must specify AccountKey when enabling Remote Management if not previously configured.) enable or disable Cellular and allows setting of the APN ping IP address
CONFIGURING SMS
60
SMS Command
#apn #cellular #radio #ethernet #wan #serial #wifi
Description
get APN string PPP status radio status Ethernet LAN configuration details WAN transport type and WAN priority configuration get serial details: Mode (Server or Client), RX bytes, TX bytes, DCD Status, Protocol, Port (Server mode only), Server IP Address (Client mode only), and Server Port (Client Mode only) get Wi-Fi details: Date and time in format YYYY-MM-DD HH:MM, mode (WAN or Access Point), MAC address, status (for WAN mode only), SSID, Security settings (for Access Point only, None, WEP, WPA, WPA2-PSK, and WPA/WPA2-PSK)
Note:
Arguments in square brackets [ ] are optional. Those in angle brackets < > are values.
Sending an SMS Message
To send an SMS message from the router:
1.
2.
3.
4.
Go to In the In the Click
Send
or not.
SMS > Send SMS Recipient Message Send SMS
window.
field, enter a phone number and click
Add
. You can add up to 100 phone numbers.
field, enter a text message up to 160 characters long.
. The system displays a confirmation indicating whether the message has been successfully sent
Viewing Received SMS Messages
To view received SMS messages from the router:
1.
2.
3.
4.
5.
Go to
SMS > Received
to display the
Received SMS
window. The messages are sorted by date with the most recent messages on top. The table shows up to 30 characters for each message.
To view the full message, click the
eye
icon to the right of the message entry.
To delete an SMS message, click the
trash can
icon under
Options
to the right of the message. A dialog box asks you to confirm that you want to delete the SMS message. Click
OK
.
To delete all the received SMS messages, click to delete all SMS messages. Click
OK
.
Delete All
. A dialog box asks you to confirm that you want To configure, the receive list to automatically update, check the corner.
Auto Refresh
box in the upper right
Viewing Sent SMS Messages
To view sent SMS messages from the router: MultiConnect ® rCell 100 MTR-H6 User Guide
CONFIGURING SMS 1.
2.
3.
4.
5.
Go to
SMS > Sent
to display the
Sent SMS
window. The messages are sorted by date with the most recent messages on top. The table shows up to 30 characters for each message.
To view a full message, click the
eye
icon to the right of the message entry.
To delete a sent SMS message, click the
trash can
icon to the right of the message entry. A dialog box asks you to confirm that you want to delete the SMS message. Click
OK
.
To delete all the sent SMS messages, click delete all the SMS messages. Click
OK
.
Delete All
. A dialog box asks you to confirm that you want to To configure, the receive list to automatically update, check the corner.
Auto Refresh
box in the upper right MultiConnect ® rCell 100 MTR-H6 User Guide 61
DEFINING TUNNELS
Chapter 11 – Defining Tunnels Setting Up GRE Tunnels
Tunneling allows the use of a public network to convey data on behalf of two remote private networks. It is also a way to transform data frames to allow them to pass networks with incompatible address spaces or even incompatible protocols. Generic Routing Encapsulation (GRE) is a tunneling mechanism that uses IP as the transport protocol and can be used for carrying many different passenger protocols.
The tunnels behave as virtual point-to-point links that have two endpoints identified by the tunnel source and tunnel destination addresses at each endpoint. Configuring a GRE tunnel involves creating a tunnel interface, which is a logical interface, then configuring the tunnel endpoints for the tunnel interface. To set up GRE tunnels:
1.
2.
3.
4.
5.
From the Web Management interface, go to Click In the
Tunnel Name
(Optional) In the
Description
In the next wizard pane:
Tunnels > GRE Tunnels > GRE Tunnels Configuration Add Tunnel
. A series of wizard pages helps you configure the connection.
field, enter a name for the new tunnel.
.
field, you can enter a description that helps you further identify the tunnel.
5.
6.
a.
b.
In the
Remote WAN IP
field, type the IP address of the gateway to which you want to connect.
Click
Add
under
Remote Network Routes
.
c.
1.
2.
3.
4.
In the (Optional) From the through it.
Saved Network
drop-down list, select the network that is to be routed through the tunnel. To select a local interface: Select the local interface on which the tunnel is being created. Eventually, the packets destined for this tunnel will be routed If you are not using a saved network, in the
Remote Network Route
address of the network that is routed through the tunnel.
field, type the IP If you are not using a saved network, in the the network.
Remote Network Mask
field, type the mask of Click
Add
.
Checking Period
field, enter the timeout interval in minutes. The default is 10 minutes.
Click
Submit
.
To save your changes, click
Save and Restart
.
Configuring Network-to-Network Virtual Private Networks (VPNs)
The device supports site-to-site VPNs via IPsec tunnels for secure network-to-network communication. Both tunnel endpoints should have static public IP addresses and must be able to agree on the encryption and authentication methods to use. Setting up an IPsec tunnel is a two-stage negotiation process. The first stage negotiates how the key exchange is protected. The second stage negotiates how the data passing through the tunnel is protected. For endpoints that do not have public static IP addresses, additional options may help such as
NAT Traversal
and
Aggressive Mode
.
By default, based on the encryption method chosen, the device negotiates ISAKMP hash and group policies from a default set of secure algorithms with no known vulnerabilities. This allows flexibility in establishing connections with remote endpoints. There is an
ADVANCED
mode that provides a way to specify a strict set of algorithms to use per phase, limiting the remote endpoint's negotiation options.
62 MultiConnect ® rCell 100 MTR-H6 User Guide
DEFINING TUNNELS
The default set of Hash Algorithms is:
SHA-1, SHA-2
, and
MD5
.
The default set of DH Group Algorithms is:
DH2(1024-bit), DH5(1536-bit), DH14(2048-bit), DH15(3072-bit), DH16(4096-bit), DH17(6144-bit), DH18(8192-bit), DH22(1024-bit), DH23(2048-bit)
, and
DH24(2048-bit)
.
To set up a Network-to-Network VPN tunnel on your router:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
From the Web Management interface, go to
Tunnels > IPsec Tunnels
.
Click
Add Tunnel
in upper right.
Enter a
Name
for the tunnel and an optional
Description
.
Click
Next
. The
IPsec Remote Tunnel Endpoint
pane opens.
Under the
Saved Network
entering the drop-down, you can add a saved network
Remote Network Route
(LAN IP) and
OR
enter a network manually by
Remote Network Mask
(Subnet).
Choose
Tunnel Type
from the drop-down. Values are
IKE
and
IKEv2
.
The public IP address and LAN of this device do not need to be configured because they are already known by this device.
Select the
Authentication Method
from the drop-down either
Pre-Shared Key
or
RSA Signatures
.
Authentication is performed using secret pre-shared keys and hashing algorithms (like
SHA1 MD5
) or RSA signatures.
If you select
Pre-Shared Key
, then enter the
Secret
. This key needs to be the same on both endpoints.
If you select
RSA Signatures
, enter the following (in .pem format):
a.
b.
c.
CA Certificate Local RSA Certificate Local RSA Private Key 11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
Select the
Encryption Method
from the drop-down including
3DES, AES-128, AES-192, AES-256
, or
ADVANCED
. The encryption method needs to be the same on both endpoints. IKE encryption algorithm is used for the connection (
phase 1 - ISAKMP SA)
. Based off of
phase 1
, a secure set of defaults are used for
phase 2
, unless you use the
Advanced
option, in which case, you must specify all components of both
phases 1 and 2
including
Encryption
,
Authentication
, and
Key Group
.
If the remote endpoint is set up with unique IDs, check the
Remote IDs
.
Enable UID
box, and enter the
Local
and Click
Show
for
IPSec Tunnel: Advanced
features that limit the remote endpoint's negotiation options.
In the
IKE Lifetime
field, enter the duration in which ISAKMP SA lasts (in hours).
In the
Max Retries
field, enter the number of retries for the IPSec Tunnel. Enter zero for unlimited retries.
In the
Key Life
field, duration in which the IPSec SA lasts (in hours).
In the
Checking Period
field, enter the timeout interval (in minutes).
Check
Compression
to enable IPComp (compression algorithm).
Check
Aggressive Mode
to enable exchange identification in plain text (unencrypted for faster negotiation). NOTE: This mode is less secure and prone to dictionary and brute force attacks.
Click
Submit
.
To save your changes, click
Save and Restart
.
For field descriptions, see
IPsec Tunnel Configuration Field Descriptions .
MultiConnect ® rCell 100 MTR-H6 User Guide 63
DEFINING TUNNELS
IPsec Tunnel Configuration Field Descriptions
Field IPSec Tunnel Name Description Description
Name used to identify the IPsec tunnel in configurations and logs.
Optional text to describe the IPsec tunnel. This description shows up in the UI while hovering over the summary of an IPsec tunnel.
IPSec Remote Tunnel Endpoint Remote WAN IP Saved Network Remote Network Route Remote Network Mask Tunnel Type
External IP address of the remote tunnel endpoint. The remote device is typically another router.
Select a saved network from the pre-defined list of user-defined networks on the
Setup > Saved Networks
page. This network describes the remote endpoint's subnet, and is used to identify packets that are routed over the tunnel to the remote network.
This field is used in conjunction with the
Remote Network Mask
field and describes the remote endpoint's subnet. This is used to identify packets that are routed over the tunnel to the remote network.
This field is used in conjunction with the
Remote Network Route
field, to describe the remote endpoint's subnet. It identifies packets that are routed over the tunnel to the remote network.
Internet Key Exchange (IKE) for host-to-host, host-to-subnet, or subnet to-subnet tunnels. Choose from
IKE
or
IKEv2
.
IPsec Tunnel: IKE Authentication Method Pre-Shared Key Secret Encryption Method RSA Signatures CA Certificate Local RSA Certificate Local RSA Private Key
Choose between
Pre-Shared Key
or
RSA Signatures
SHA1 MD5) or RSA signatures (you provide the . Authentication is performed using secret pre-shared keys and hashing algorithms (like
CA Certificate, Local RSA Certificate
, and
Local RSA Private Key Enable UID
, then
Local ID
and in .pem format). If you check
Remote ID
become available as options.
Authentication is performed using a secret pre-shared key and hashing algorithms on both sides.
Secret key that is known by both endpoints.
IKE encryption algorithm used for the connection (phase 1 - ISAKMP SA).
Based off of phase 1, a secure set of defaults are used for phase 2, unless the
Advanced
option is used, in which case, all components of both phases 1 and 2 are specified by the user.
Authentication is performed using digital RSA signatures.
Certificate Authority certificate used to verify the remote endpoint's certificate.
Certificate the local endpoint uses during
Phase 1 Authentication
.
The private key that the local endpoint uses during Phase 1 Authentication.
64 MultiConnect ® rCell 100 MTR-H6 User Guide
Field Encryption Method Phase 1 Encryption Phase 1 Authentication Phase 1 Key Group Phase 2 Encryption Phase 2 Authentication Phase 2 Key Group Enable UID Local ID Remote ID IPSec Tunnel: Advanced IKE Lifetime Key Life Max Retries Compression
MultiConnect ® rCell 100 MTR-H6 User Guide
DEFINING TUNNELS Description
Choose an
Encryption Method
from the following list:
3DES, AES-128, AES-192, AES-256,
user.
or
ADVANCED
. IKE encryption algorithm is used for the connection (phase 1 - ISAKMP SA). Based off of phase 1, a secure set of defaults are used for phase 2, unless the
Advanced
option is used, in which case, all components of both phases 1 and 2 are specified by the If
Advanced Encryption
is selected for
Encryption Method
from the drop-drown: , select
Phase 1 3DES, AES-128, AES-192, AES-256, ANY AES
, or
ANY
.
If
Advanced
is selected for
Authentication SHA2-384, SHA2-512
, or
Encryption Method
, select from the drop-drown:
ANY
.
Phase 1 MD5, SHA-1, SHA-2, SHA2-256,
If
Advanced
is selected for
Encryption Method
, select the
Phase 1 Key Group
from the drop-down:
DH2 (1024-bit), DH5 (1536-bit), D14 (2048 bit), DH15 (3072-bit), DH16 (4096-bit), DH17 (6144-bit), DH18 (8192 bit), DH22 (1024-bit), DH23 (2048-bit), DH24 (2048-bit),
and
ANY
.
If
Advanced Encryption
is selected for
Encryption Method
from the drop-drown: , select
Phase 2 3DES, AES-128, AES-192, AES-256, ANY AES,
or
ANY
.
If
Advanced
is selected for
Authentication SHA2-384, SHA2-512,
or
Encryption Method
, select from the drop-drown:
ANY
.
Phase 2 MD5, SHA-1, SHA-2, SHA2-256,
If
Advanced
is selected for
Encryption Method
, select the
Phase 2 Key Group
from the drop-down:
DH2 (1024-bit), DH5 (1536-bit), D14 (2048 bit), DH15 (3072-bit), DH16 (4096-bit), DH17 (6144-bit), DH18 (8192 bit), DH22 (1024-bit), DH23 (2048-bit), DH24 (2048-bit),
and
ANY
.
Unique Identifier String to enable the
Local ID
and
Remote ID
fields.
String Identifier for the local security gateway (optional) String Identifier for the remote security gateway (optional) Duration for which the ISAKMP SA exists from successful negotiation to expiration.
Duration for which the IPsec SA exists from successful negotiation to expiration.
Number of retry attempts for establishing the IPsec tunnel. Enter zero for unlimited retries.
Enable IPComp. This protocol increases the overall communication performance by compressing the datagrams. Compression requires greater CPU processing.
65
DEFINING TUNNELS
66
Field Aggressive Mode Description
Whether to allow a less secure mode that exchanges identification in plain text. This may be used for establishing tunnels where one or more endpoints have a dynamic public IP address. Although this mode is faster to negotiate phase 1, the authentication hash is transmitted unencrypted. You can capture the hash and start a dictionary or use brute force attacks to recover the PSK.
OpenVPN Tunnels
OpenVPN is an open-source software application that implements virtual private network (VPN) techniques for creating secure point-to-point or site-to-site connections in routed or bridged configurations and remote access facilities. You can use and setup OpenVPN tunnels with this device.
To use OpenVPN, you must first install an OpenVPN application along with an easy-rsa tool and configure OpenVPN on your computer. Then you must also generate the certificates for the OpenVPN server and client before configuring the device.
To configure OpenVPN client and server on this device the following files are required:
The CA PEM file or CA certificate (.crt) The Diffie Hellman PEM file (.pem) The Server Certificate to be used by the device endpoint (.crt) The Server/Client Key to be used by the device endpoint (.key) Note:
When you configure OpenVPN server and client make sure both sides use the same settings, and certificates.
Configuration 1: OpenVPN Tunnel with TLS Authorization Mode (Device only)
This first configuration establishes the OpenVPN Tunnel connection from a device client to a device server using TLS as Authorization Mode. This involves adding and configuring both OpenVPN Server and Client sides within the device UI.
To add an
OpenVPN Server using TLS
:
1.
2.
3.
4.
5.
6.
You can also enter an optional
a.
b.
c.
d.
e.
f.
g.
Go to
Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration
.
Click
Add Tunnel
.
Enter the
Name
.
Select the
Type
as
SERVER
from the drop-down.
Description
.
Under OpenVPN Tunnel Configuration, enter the following fields (using
Interface Type
as
TUN
from the drop-down.
Authorization Mode
as
TLS
from the drop-down.
Protocol
as
UDP
.
VPN Subnet
.
Port
number.
VPN Netmask
.
LZO Compression
as
ADAPTIVE
from the drop-down.
TLS
as
Authorization Mode
): MultiConnect ® rCell 100 MTR-H6 User Guide
DEFINING TUNNELS h.
i.
j.
k.
l.
m.
Hash Algorithm
as
DEFAULT
.
Encryption Cipher
as
DEFAULT
.
Min. TLS Version
as
1.2
.
TLS Cipher Suite
as
DEFAULT
as
1.2
.
Enter the contents of the following files generated from the easy-rsa tool. You can copy and paste this content from the certificate files after opening from a text editor like Notepad. (all required):
i.
ii.
iii.
iv.
CA PEM (.crt) Diffie Hellman PEM (.pem) Server Certificate PEM (.crt) Server Key PEM (.key)
Select the
Encryption Cipher 7.
8.
Click
Next
.
Note: Use the same
CA PEM
certificate and parameters as the server for the OpenVPN clients .
Remote Network Routes
create a route from the server network to the client network. This allows the server to get an access to the client’s network. In the
OpenVPN Tunnel
dialog box, under
Remote Network Routes
:
a.
b.
c.
d.
e.
Choose an available
Saved Network
(optional).
as your remote network route from the drop-down if desired Or enter the
Remote Network Route
(should be the client subnet). For example, if the client IP address is 192.168.3.1, enter 192.168.3.0.
Enter the
Remote Network Mask
(usually 255.255.255.0).
You may enter
Gateway
(optional).
Click
Add Route
.
9.
10.
The system displays your recently-added mask).
Push Route
with the client subnet (remote network route +
Push Routes
create a route from client’s network to the server’s network. This allows clients to get access to the server’s network. Under
Push Routes
:
a.
b.
c.
d.
e.
f.
Click
Client To Client
box if you want this optional feature (this establishes a connection between multiple clients that are connected to the server).
Choose an available
Saved Network
as your push route from the drop-down if desired (optional).
Or enter the
Remote Network Route
(same address as the server subnet above).
Or enter the
Remote Network Mask
(same as above).
You may enter
Gateway
(optional).
Click
Add Route
.
Note: If you use
Static Key Authorization Mode
, the
Push Routes
do not work.
11.
12.
13.
14.
The system displays your recently-added mask).
Push Route
with the client subnet (remote network route + Click
Next
.
The system displays the
Configuration Preview
window (read-only).
Click
Finish
.
MultiConnect ® rCell 100 MTR-H6 User Guide 67
DEFINING TUNNELS 15.
Click
Save and Restart
to save your changes To add an
OpenVPN Client using TLS
:
1.
2.
3.
4.
5.
6.
Go to Click
Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration Add Tunnel
.
Enter the Select the
Name
of the tunnel.
Type
as
CLIENT
from the drop-down.
You can also enter an optional
Description
.
.
Under OpenVPN Tunnel Configuration, enter the following fields (using
TLS
as
Authorization Mode
):
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
k.
Interface Type
as
TUN
from the drop-down.
Authorization Mode
as
TLS
from the drop-down.
Protocol
as
UDP
.
Remote Host
(server public IP address).
Remote Port
number.
LZO Compression
as
ADAPTIVE
from the drop-down.
Hash Algorithm
as
DEFAULT
.
Encryption Cipher
as
DEFAULT.
Min. TLS Version
as
1.2.
TLS Cipher Suite
as
DEFAULT
.
Enter the contents of the following files generated from the easy-rsa tool. You can copy and paste this content from the certificate files after opening from a text editor like Notepad. (all required):
i.
ii.
iii.
CA PEM (.crt) Client Certificate PEM (.crt) Client Key PEM (.key)
Click Next.
l.
7.
8.
9.
10.
11.
If you use
TLS
as
Authorization Mode
server adds the routes if the server's
Authorization Mode
, you do not need configure or add
Push Routes
, you must add and configure
Remote Network Routes
. The are already configured. If you use
Remote Network Routes
.
Static Key
as Click
Next
.
The system displays the
Configuration Preview
window (read-only).
Click
Finish
.
Click
Save and Restart
to save your changes.
Now the device client can access the device server subnet. You can ping the IP address of the device server subnet from the client console to test this.
Note:
The PC connected to the device does not have access to the device server subnet.
Configuration 2: OpenVPN Tunnel with TLS Authorization Mode (Device and Connected PC)
This second configuration provides access between a device server and its subnet and device client and its subnet.
An additional configuration is needed on the device server side. This also allows your PC to connect with the device server and ultimately to the device client through that server.
68 MultiConnect ® rCell 100 MTR-H6 User Guide
DEFINING TUNNELS 1.
2.
3.
Configure the device server as shown under how to add an
OpenVPN Server using TLS
(steps 1-14).
Open device console, go to in the device.
/var/config/ovpnccd/openVPNServerName
. Create the folder if not present Create a file that has the client certificate name with the following information:
a.
b.
iroute [Client_Subnet] [Mask
]
example
-- echo “iroute 192.168.3.0 255.255.255.0” > mtrClient1
4.
5.
For each client, you must create a separate file in the folder
/var/config/ovpnccd/yourserverName
.
Note:
Make the file name the same as the Common Name value used to create the certificate.
Configure device client as shown under how to
add an OpenVPN Client
(steps 1-12).
Once properly configured, you should have a connection between the device server and device client and their subnets. Your PC can also connect with the device server and thus the device client through that server.
Configuration 3: OpenVPN Tunnel with Static Key Authorization Mode (device server and client)
This third configuration establishes the OpenVPN Tunnel connection from a device client to a device server using Static Key as Authorization Mode. This involves adding and configuring both OpenVPN Server and Client sides within the device UI.
When using Static Key, the OpenVPN tunnel is created between only two end-points, the client and server. You cannot connect more than one client to the server in this mode. Remote Network Route must be specified in both configurations, client and server, in order to establish the connection between subnets.
To add an
OpenVPN Server using Static Key
:
1.
2.
3.
4.
5.
6.
7.
Go to Click
Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration Add Tunnel
.
Enter the Select the Click
Next
.
Name
.
Type
as
SERVER
from the drop-down.
You can also enter an optional Enter the following fields (using
Description
.
STATIC KEY
as
Authorization Mode
): .
g.
h.
i.
j.
a.
b.
c.
d.
e.
f.
Interface Type
as
TUN
from the drop-down.
Authorization Mode
as
STATIC KEY
from the drop-down.
Protocol
as
UDP
.
Local Address
as
DEFAULT
.
Port
number.
Remote Address
as
DEFAULT
.
LZO Compression
as
ADAPTIVE
from the drop-down.
Hash Algorithm
as
DEFAULT
.
Encryption Cipher
as
DEFAULT
.
Generate and enter the key. See example below:
Static Key PEM
(required). Both server and client must use the same static -----BEGIN OpenVPN Static key V1---- 3f4c9113b2ec15a421cfe21a5af015bb967059021c1fd6f66ecfd00533d967237875215e20e80a2d59efd 79148d6acdea9358dcafe0efdbb54003ff376c71432dd9d16f55e7d8917a32bfe07d61591b7bbb43c7ba MultiConnect ® rCell 100 MTR-H6 User Guide 69
DEFINING TUNNELS
70
8.
9.
d214482b8547ec9dca8910f514d9f4270ccaeff1a79852ae27c1c307c9dc3c836d1c380bece3c70fd2104 e1968ed29b6c3388719226f959f69f9be43688ed27bc3a4dbc83f640370524b47bb871816af79586d07 08781fad384480d0609b11c31d27baa6e902d29277a474e3e2785a8410d595c0f9c75312375b4bd098 76e1a47a598e114749a09c35f098e9123015c2795c702e4a346a8bccd00305c7cb30beef66ad33f43dac c2e662128 -----END OpenVPN Static key V1---- Click
Next
.
Remote Network Routes
create a route from the server network to the client network. This allows the server to get access to the client’s network. In the
OpenVPN Tunnel
dialog box, under
Remote Network Routes
:
a.
b.
c.
d.
Choose an available
Saved Network
(optional).
as your remote network route from the drop-down if desired Or enter the
Remote Network Route
(should be the client subnet). For example, if the client IP address is 192.168.3.1, enter 192.168.3.0.
Enter the
Remote Network Mask
(usually 255.255.255.0).
Click
Add Route
.
10.
11.
12.
13.
14.
The system displays your recently-added route + mask).
Remote Network Route
with the client subnet (remote network Note:
Push Routes are not required with Static Key as Authorization Mode.
Click
Next
.
The system displays the
Configuration Preview
window (read-only).
Click
Finish.
Click
Save and Restart
to save your changes.
To add an
OpenVPN Client using Static Key
:
1.
2.
3.
4.
5.
6.
7.
Go to Click
Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration Add Tunnel
Enter the
Name
.
Select the
Type
Click
Next
.
.
as
CLIENT
from the drop-down.
You can also enter an optional Enter the following fields (using
Description
.
STATIC KEY
as
Authorization Mode
): .
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
Interface Type
as
TUN
from the drop-down.
Authorization Mode
as
STATIC KEY
from the drop-down.
Protocol
as
UDP
.
Local Address
as
DEFAULT
.
Remote Host
.
Remote Address
as
DEFAULT
.
Remote Port
number.
LZO Compression
as
ADAPTIVE
from the drop-down.
Select the
Encryption Cipher
as
DEFAULT
from drop-down.
Select the
Hash Algorithm
as
DEFAULT
from drop-down.
MultiConnect ® rCell 100 MTR-H6 User Guide
DEFINING TUNNELS 8.
9.
k.
l.
m.
Min. TLS Version
as
1.2.
TLS Cipher Suite
as
DEFAULT
.
Enter the
Static Key PEM
example below: (required). Both server and client must use the same static key. See -----BEGIN OpenVPN Static key V1---- 3f4c9113b2ec15a421cfe21a5af015bb967059021c1fd6f66ecfd00533d967237875215e20e80a2d59efd 79148d6acdea9358dcafe0efdbb54003ff376c71432dd9d16f55e7d8917a32bfe07d61591b7bbb43c7ba d214482b8547ec9dca8910f514d9f4270ccaeff1a79852ae27c1c307c9dc3c836d1c380bece3c70fd2104 e1968ed29b6c3388719226f959f69f9be43688ed27bc3a4dbc83f640370524b47bb871816af79586d07 08781fad384480d0609b11c31d27baa6e902d29277a474e3e2785a8410d595c0f9c75312375b4bd098 76e1a47a598e114749a09c35f098e9123015c2795c702e4a346a8bccd00305c7cb30beef66ad33f43dac c2e662128 -----END OpenVPN Static key V1-----.
Click
Next
.
Remote Network Routes
create a route from the server network to the client network. This allows the client to get access to the server's network. In the
OpenVPN Tunnel
dialog box, under
Remote Network Routes
:
a.
b.
c.
d.
Choose an available
Saved Network
(optional).
as your remote network route from the drop-down if desired Or enter the
Remote Network Route
(should be the client subnet). For example, if the client IP address is 192.168.2.1, enter 192.168.2.0.
Enter the
Remote Network Mask
(usually 255.255.255.0).
Click
Add Route
.
10.
11.
12.
13.
14.
The system displays your recently-added route + mask).
Remote Network Route
with the client subnet (remote network Note:
Push Routes
are not required with
Static Key
as
Authorization Mode.
Click
Next
.
The system displays the
Configuration Preview
window (read-only).
Click
Finish
.
Click
Save and Restart
to save your changes.
Configuration 4: OpenVPN Tunnel with Static Key Authorization Mode and TCP
This fourth configuration establishes the OpenVPN Tunnel connection from a device client to a device server using Static Key as Authorization Mode and TCP protocol (instead of UDP for the third configuration). This involves adding and configuring both OpenVPN Server and Client sides within the device UI.
To add an
OpenVPN Server using Static Key and TCP
:
1.
2.
3.
4.
5.
6.
Go to
Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration
.
Click
Add Tunnel
.
Enter the
Name
.
Select the
Type
as
SERVER
from the drop-down.
You can also enter an optional
Description
.
Click
Next
.
MultiConnect ® rCell 100 MTR-H6 User Guide 71
DEFINING TUNNELS 7.
8.
9.
Enter the following fields (using
STATIC KEY
as
Authorization Mode
):
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
k.
l.
Interface Type
as
TUN
from the drop-down.
Authorization Mode
as
STATIC KEY
from the drop-down.
Protocol
as
TCP
.
Local Address
as
DEFAULT
.
Port
number.
Remote Address
as
DEFAULT
.
Hash Algorithm
as
ECDSA-WITH-SHA1
.
LZO Compression
as
ADAPTIVE
from the drop-down.
Encryption Cipher
as
CAMELLIA-256-CBC
.
Min. TLS Version
as
NONE.
TLS Cipher Suite
as
DEFAULT
.
Generate and enter the key. See example below:
Static Key PEM
(required). Both server and client must use the same static -----BEGIN OpenVPN Static key V1---- 3f4c9113b2ec15a421cfe21a5af015bb967059021c1fd6f66ecfd00533d967237875215e20e80a2d59efd 79148d6acdea9358dcafe0efdbb54003ff376c71432dd9d16f55e7d8917a32bfe07d61591b7bbb43c7ba d214482b8547ec9dca8910f514d9f4270ccaeff1a79852ae27c1c307c9dc3c836d1c380bece3c70fd2104 e1968ed29b6c3388719226f959f69f9be43688ed27bc3a4dbc83f640370524b47bb871816af79586d07 08781fad384480d0609b11c31d27baa6e902d29277a474e3e2785a8410d595c0f9c75312375b4bd098 76e1a47a598e114749a09c35f098e9123015c2795c702e4a346a8bccd00305c7cb30beef66ad33f43dac c2e662128 -----END OpenVPN Static key V1---- Click
Next
.
Remote Network Routes
create a route from the server network to the client network. This allows the server to get access to the client’s network. In the
OpenVPN Tunnel
dialog box, under
Remote Network Routes
:
a.
b.
c.
d.
Choose an available
Saved Network
(optional).
as your remote network route from the drop-down if desired Or enter the
Remote Network Route
(should be the client subnet). For example, if the client IP address is 192.168.3.1, enter 192.168.3.0.
Enter the
Remote Network Mask
(usually 255.255.255.0).
Or click
Add Route
.
10.
11.
12.
13.
14.
The system displays your recently-added route + mask).
Remote Network Route
with the client subnet (remote network Note:
Push Routes are not required with Static Key as Authorization Mode.
Click
Next.
The system displays the
Configuration Preview
window (read-only).
Click
Finish
.
Click
Save and Restart
to save your changes.
To add an
OpenVPN Client using Static Key and TCP
: 72 MultiConnect ® rCell 100 MTR-H6 User Guide
DEFINING TUNNELS 1.
2.
3.
4.
5.
6.
7.
i.
j.
k.
l.
m.
a.
b.
c.
d.
e.
f.
g.
h.
Go to
Tunnels > OpenVPN Tunnels > OpenVPN Tunnel Configuration
.
Click
Add Tunnel
.
Enter the
Name
.
Select the
Type
as
CLIENT
from the drop-down.
You can also enter an optional
Description
.
Click
Next
.
Enter the following fields (using
STATIC KEY
as
Authorization Mode
):
Interface Type Authorization Mode Protocol
as
TCP Local Address Remote Host Remote Port
.
as .
as
TUN DEFAULT Remote Address
as number.
Hash Algorithm
as
Encryption Cipher
as
Min. TLS Version
as
TLS Cipher Suite
as as from the drop-down.
STATIC KEY NONE.
.
DEFAULT
.
from the drop-down.
ECDSA-WITH-SHA1
.
LZO Compression
as
ADAPTIVE DEFAULT
.
from the drop-down.
CAMELLIA-256-CBC
.
Generate and enter the key. See example below:
Static Key PEM
(required). Both server and client must use the same static -----BEGIN OpenVPN Static key V1---- 3f4c9113b2ec15a421cfe21a5af015bb967059021c1fd6f66ecfd00533d967237875215e20e80a2d59efd 79148d6acdea9358dcafe0efdbb54003ff376c71432dd9d16f55e7d8917a32bfe07d61591b7bbb43c7ba d214482b8547ec9dca8910f514d9f4270ccaeff1a79852ae27c1c307c9dc3c836d1c380bece3c70fd2104 e1968ed29b6c3388719226f959f69f9be43688ed27bc3a4dbc83f640370524b47bb871816af79586d07 08781fad384480d0609b11c31d27baa6e902d29277a474e3e2785a8410d595c0f9c75312375b4bd098 76e1a47a598e114749a09c35f098e9123015c2795c702e4a346a8bccd00305c7cb30beef66ad33f43dac c2e662128 -----END OpenVPN Static key V1-----
8.
9.
Click
Next
.
Remote Network Routes create a route from the server network to the client network. This allows the client to get access to the server's network. In the
OpenVPN Tunnel
dialog box, under
Remote Network Routes
:
a.
b.
c.
d.
Choose an available
Saved Network
(optional).
as your remote network route from the drop-down if desired Or enter the
Remote Network Route
(should be the client subnet). For example, if the client IP address is 192.168.2.1, enter 192.168.2.0.
Enter the
Remote Network Mask
(usually 255.255.255.0).
Click
Add Route
.
10.
The system displays your recently-added route + mask).
Remote Network Route
with the client subnet (remote network MultiConnect ® rCell 100 MTR-H6 User Guide 73
DEFINING TUNNELS 11.
12.
13.
14.
Note:
Push Routes are not required with Static Key as Authorization Mode.
Click
Next
.
The system displays the
Configuration Preview
window (read-only).
Click
Finish
.
Click
Save and Restart
to save your changes.
Unavailable Services in PPP-IP Passthrough and Serial Modem Modes
In both
PPP-IP Passthrough
and
Serial Modem
modes, many rCell services described in this document are non configurable and therefore do not appear in the device configuration menu. If you choose one of these modes, all sections between this and the previous note on this subject are not available.
74 MultiConnect ® rCell 100 MTR-H6 User Guide
DEVICE ADMINISTRATION
Chapter 12 – Device Administration User Accounts
Use this feature to add user accounts or change the password.
The system offers three roles or user types: administrator, engineer, and monitor. Administrators have full rights and permissions including change settings on the device. Engineers have read/write privileges and some access to controls on the device. Monitors have read-only access. Note: the system automatically checks for a strong password and tells you how to improve it.
Username requirements include: Must be unique.
Is case-sensitive (for example, admin and ADMIN are treated as two different usernames).
Acceptable characters: uppercase alphabetic, lowercase alphabetic, numeric, and non-alphanumeric (symbols like #).
A hyphen (-) should not be used as the first character.
Password requirements include: User account is disabled if password is not set up.
Must be eight characters in length.
Contains three or more different types of characters such as: uppercase alphabetic, lowercase alphabetic, numeric, and non-alphanumeric (symbols like #).
Administrator details: Able to delete any local users. (Engineer and Monitor cannot delete any users.) Able to modify any other user details, except username.
Can not modify another administrator user account if it is the only enabled local administrator user on the device.
Able to modify own account details except Role, Username, and Enabled values.
Able to disable and enable any local users except their own account. Also, not able to disable local user account if this is only local administrator.
Able to change own password and other user passwords.
Engineer and Monitor details: Able to view and modify own user account details except Role, Username, and Enabled values.
Access to only their own user account.
Not able to delete users.
Able to change own password.
To add new users:
1.
2.
3.
Go to
Administration
>
User Accounts
.
Click
Add New User
.
Under
User Details
, enter the following fields: MultiConnect ® rCell 100 MTR-H6 User Guide 75
DEVICE ADMINISTRATION
76
4.
a.
b.
c.
d.
e.
f.
g.
Username (required) Role (required). Select the user role from the drop-down menu including
monitor
.
administrator
,
engineer
, or First Name Last Name Title Division Employee Identification Under
Contact Information
, enter the following fields:
a.
b.
c.
d.
e.
f.
g.
h.
Email Address City State Country Postal Code Work Phone Mobile Phone
5.
6.
7.
Click
Submit
.
The
Change Password
The
Change Password
page opens. Enter
New Password
. Click
Submit
.
page opens. Enter
New Password
. Click
Submit
.
If the password is not set up for the new user, the user is disabled until the password is set.
Self-Diagnostic
The device offers self-diagnostics or periodic monitoring of certain issues such as: flash memory checksums, memory errors or leaks, and security violations by applications.
This monitoring is intended to improve performance, detect corruption, or help prevent malicious activity. After an event is detected, the system disables the cellular radio module, sends an alarm or notification, logs the event, and sends a record of it to the SNMP server.
For the self-diagnostic features, go to
Administration > Self-Diagnostic
and refer to the following sections.
To turn on the
Resource Overuse
diagnostic that detects memory leaks or errors:
1.
2.
Check
Enabled
under
Resource Overuse
.
If you want the system to reboot the device after a
device
under
Actions.
Resource Overuse
is detected, check
Reboot the
To turn on the
Security Violation
diagnostic that detects security rule violations by applications:
1.
2.
3.
Check
Enabled
under
Security Violation
.
If you want the system to disable WAN interfaces after a
WAN Interfaces
under
Actions
.
Security Violation
is detected, check
Disable
If you want the system to disable user-defined firewall rules after a
Disable User-Defined Firewall Rules
under
Actions
.
Security Violation
is detected, check MultiConnect ® rCell 100 MTR-H6 User Guide
DEVICE ADMINISTRATION
To turn on the
Flash Memory Violation
integrity of device firmware: diagnostic that performs a flash memory checksum check to protect the
1.
2.
3.
4.
Check
Enabled
Enter the under
Flash Memory Violation Flash Memory Check Interval
.
(ranging between 4-24 hours). Default is 24.
If you want the system to disable WAN interfaces after a
Disable WAN Interfaces
under
Actions
.
Flash Memory Violation
is detected, check If you want the system to disable user-defined firewall rules after a check
Disable User-Defined Firewall Rules
under
Actions
.
Flash Memory Violation
is detected, After you completed your
Self-Diagnostic
configuration (selecting any or all of the above):
1.
2.
Click
Submit
.
To save changes, click
Save and Restart
.
If at any time you want to return the device to the default setting, click the right corner. (This disables or removes all enabled
Self-Diagnostic
features.)
Reset to Default
button in the bottom
Configuring Device Access
This section contains configurations that determine how the device can be accessed as well as security features that decrease susceptibility to malicious activity.
To display the
Configuration
.
Access Configuration
window containing the fields described below, go to
Administration > Access
HTTP Redirect to HTTPS
The device allows only secure access to its Web UI. This set of rules automatically redirects HTTP requests to the device's secure HTTPS port.
Field Enabled Port Via LAN/Ethernet Via WAN/Cellular Description
Enables HTTP to HTTPS redirect which automatically redirects users trying to access the device via HTTP to HTTPS.
The port on which the device listens for HTTP requests to redirect.
If checked, the device listens and redirects HTTP requests to HTTPS from the LAN.
If checked, the device listens and redirects HTTP requests to HTTPS from the WAN.
HTTPS
The device provides secure Web UI access to modify its configurations and execute actions.
Field Description Port
The port on which the device will listen for HTTPS requests.
MultiConnect ® rCell 100 MTR-H6 User Guide 77
DEVICE ADMINISTRATION
78
Field Via WAN/Cellular Timeout Minutes Description
If checked, the device will listen and respond to HTTPS requests from the WAN. This increases susceptibility to malicious activity.
Amount of time a user's session can remain dormant before automatically being logged out.
HTTPS Security
Configure the HTTPS security settings (like version and cipher suite). Click the
Settings
. Must select
SSL/TLS
under
Protocol
.
Show
to the right under
Security Field Use default cipher suite TLS 1.2 or TLS 1.1
Cipher Suite Name Description
Enables use of the default cipher (check by default). No other user input is required.
Check which version of the TLS protocol you want to use: TLS 1.2 or TLS 1.1. (Use default cipher suite must be unchecked.) Check your preferred Cipher Suite from the following list: ECDHE-RSA-AES256-GCM-SHA384,ECDHE-RSA AES256-SHA, DHE-RSA-AES256-GCM-SHA384, AES256 SHA, ECDHE-RSA-AES128-GCM-SHA256,ECDHE-RSA AES128-SHA, DHE-RSA-AES128-GCM-SHA256, DHE-RSA AES128-SHA, and/or AES128-SHA
SSH
The device's internal system can be accessed securely via SSH. This is intended for advanced troubleshooting and/or custom deployment solutions.
Field Enabled Port Via LAN/Ethernet Via WAN/Cellular Description
Enables SSH redirect which automatically redirects users trying to access the device via SSH.
The port on which the device listens for SSH requests.
If checked, the device listens and responds to SSH requests from the LAN.
If checked, the device listens and respond to SSH requests from the WAN.
SSH Security
Configure the select
SSL/TLS SSH security settings
under
Protocol
.
(like ciphers and HMAC). Click
Show
to the right under
Security Settings
. Must
Field Use default cipher suite Description
Enables use of the default cipher (check by default). No other user input is required.
MultiConnect ® rCell 100 MTR-H6 User Guide
DEVICE ADMINISTRATION Field Ciphers HMAC Description
Check which Cipher you want to use: AES128-CTR or AES256-CTR Check which hash-based message authentication code, you want to use: SHA1, SHA2-256,and/or SHA2-512
ICMP
Internet Control Message Protocol (ICMP) is used by devices to send error messages such as that a requested service is not available or a host or device could not be reached. ICMP can also relay query messages.
Field Enabled Respond to LAN/Via Ethernet Respond to WAN/Via Cellular Description
Enables ICMP responses.
If checked, the device will respond to ICMP traffic from the LAN, such as ping requests.
If checked, the device will respond to ICMP traffic from the WAN, such as ping requests. This increases susceptibility to malicious activity.
SNMP
The device offers Simple Network Management Protocol (SNMP) which is used for collecting information from, and configuring network devices on an IP network. For more details, refer to
Configuring SNMP
.
Field Via LAN Via WAN Description
Allows SNMP connections via LAN Allows SNMP connections via WAN.
Modbus Slave
The Modbus feature allows the user to enable the Modbus query server. You can query this server over Modbus TCP for status information.
Field Enabled
(under
Modbus Slave
)
Via LAN Port Description
Enables the Modbus Query Server.
If checked, the device can query the Modbus server via LAN.
Port number configured for Modbus.
For Modbus query information, refer to the MTR Modbus Information page on our Developer Resources website (on .net) for details: http://www.multitech.net/developer/software/mtr-software/mtr-modbus-information/ After making all your desired changes, click
Submit
, then click
Save and Restart
.
IP Defense
A set of rules that decreases susceptibility to malicious activity. If these settings are configured too strictly, they may interfere with non-malicious activity.
MultiConnect ® rCell 100 MTR-H6 User Guide 79
DEVICE ADMINISTRATION DoS Prevention
This area of the Access Configuration window engages a set of rules at the firewall that prevents Denial-of-Service attacks by limiting the amount of new connection requests to the device.
Field Description Enabled
Enables DoS prevention.
Per Minute Burst
Allowed number of new connections per minute until burst points are consumed. For example, if 60 new connections are received in a minute, decrement one burst point. If no more burst points, drop the packet.
Number of allowed burst for traffic spikes. A burst occurs when the Per Minute limit is reached. On a period where the Per Minute limit is not reached, one burst point is regained, up to the maximum.
Ping Limit
This area of the Access Configuration window engages a set of rules at the firewall that aims to prevent ping flood attacks by limiting the number of ICMP requests to the device. These rules that mitigate the effects of a ping DoS on your device do not apply if ICMP is disabled.
Field Description Enabled
Enables the Ping Limit feature.
Per Second Burst
Allowed number of pings per second before burst points are consumed. Once burst points run out, ICMP packets will be dropped.
Number of burst points. On a period where the Per Second limit is not reached, one burst point is regained, up to this maximum.
Brute Force Protection
This feature tracks login attempts at the RESTFUL API level. Its purpose is to prevent Dictionary attacks that attempt to brute force the user's password.
Field Description Enabled
Enables the Brute Force Prevention feature.
Attempts Lockout Minutes
The number of failed attempts allowed before the user's account is locked out.
The number of minutes an account is locked out before a new login attempt will be accepted.
RADIUS Configuration
The RADIUS protocol supports authentication, user session accounting, and authorization of users to the device.
This authentication, accounting, and authorization is independent of the local users created on the device. The user can enable Authentication, Accounting, or both options.
80 MultiConnect ® rCell 100 MTR-H6 User Guide
DEVICE ADMINISTRATION
RADIUS user details: Access to device if role is one of those in the provided list (Administrator, Engineer, or Monitor).
All RADIUS users do not have SSH access to the device.
RADIUS creates a temporary session instead of a local account like local users.
RADIUS uses shared key encryption.
Local users shall take priority over RADIUS user (if a RADIUS user has the same username as a local user, the RADIUS user cannot log in even if the local user is disabled).
RADIUS user with Administrator role can view and modify all local users (but cannot delete a local Administrator if it is the only local admin user on the device).
RADIUS users with Engineer and Monitor role cannot view or modify user details. They do not have access to the
User Accounts
page.
RADIUS users cannot change their own password in the Web UI.
To set up the RADIUS server configuration:
1.
2.
3.
4.
5.
Go to
a.
b.
c.
d.
e.
f.
Administration
Primary Server Secondary Server >
RADIUS Configuration
.
To enable authentication, check To enable accounting, check Enter the following fields for
Enable Authentication
.
Enable Accounting
.
RADIUS configuration
: Authentication Port (for Primary Server) Accounting Port (for Primary Server) Authentication Port (for Secondary Server) Accounting Port (for Secondary Server) Under
Options
, enter the following fields:
6.
a.
b.
c.
d.
Shared Secret Key
value is used to: 1) encrypt packets between the RADIUS Server and device, 2) encrypt RADIUS attributes such as user password, and 3) verify that RADIUS messages have not been modified in transit. This value must be equal to the shared secret that is set up in RADIUS server. The Shared Secret Key can be up to 128 characters long. You can click the eye icon to hide the key.
Authentication Protocol: select from drop-down list including
TTLS/PAPv0 PAP
,
EAP-PEAPv0/MSCHAPv2
, or
EAP-
Timeout is the interval in seconds between tries to connect to RADIUS server in case of communication failure. Maximum is 10 seconds.
Retries is the number of tries to connect to RADIUS server in case of communication failure.
Advanced Options are used when Authentication Protocol is EAP-PEAPv0/MSCHAPv2 or EAP-TTLS/PAPv0.
If Protocol is PAP, these settings are ignored:
a.
b.
Check
Use Anonymous ID
if you want to enable identity privacy. The device does not send its identity in plain text before the device has authenticated the RADIUS server.
Anonymous ID is a name or value that the device will use in the identity response when “Use Anonymous ID” is enabled.
MultiConnect ® rCell 100 MTR-H6 User Guide 81
DEVICE ADMINISTRATION
82
7.
8.
c.
Check
Check Server Certificate Hostname
validated by the device.
to allow the server certificate CN (common name) to be Click
Submit
.
To save your changes, click
Save and Restart
Unavailable Services in PPP-IP Passthrough and Serial Modem Modes
In both
PPP-IP Passthrough
and
Serial Modem
modes, many rCell services described in this document are non configurable and therefore do not appear in the device configuration menu. If you choose one of these modes, all sections between this and the next note on this subject are not available.
Generating a New Certificate
Because the router uses a self-signed website certificate, your browser shows a certificate error or warning. Ignore the warning and add an exception or add your device address to the trusted sites.
To generate a new certificate:
4.
5.
6.
7.
8.
9.
1.
2.
3.
10.
11.
Go to
Administration > X.509 Certificate
. The certificate that is currently used.
X.509 Certificate
window displays the details of the Click
Generate
to open the
Generate Certificate
window.
In the
Common Name
field, enter the name, hostname, or IP address, depending on what you use to connect to the router. The web browser uses this field to check for a valid certificate.
In the
Days
field, enter the amount of days before the certificate will expire.
In the
Country
field, enter the 2-letter code for the country name.
In the
State/Province
field, enter the state or province for which the certificate is valid.
In the
Locality/City
field, enter the locality or the city for which the certificate is valid.
In the
Organization
field, enter the organization name for which the certificate is valid.
In the
Email Address
field, enter the email address of the person responsible for the router. Typically this is the administrator. This field may be left blank.
Click
Generate
. Wait until the certificate is generated. You may have to reboot to complete the operation.
If you are finished making changes, click
Save and Restart
.
Importing a Certificate
To import a certificate:
1.
Go to
Administration > X.509 Certificate
. The Certificate window displays the details of the certificate that is currently used.
NOTE:
A certificate with a key size greater than 2048 bits causes a delay accessing the Web UI after the device starts. A certificate with a key size less than 2048 bits is not recommended since it is less secure and may become breakable in the near future.
2.
Click
Import
to open
Upload Certificate
window.
3.
4.
Click
Browse
to select a valid certificate to be uploaded.
Click
Upload
. Wait until the file is uploaded.
MultiConnect ® rCell 100 MTR-H6 User Guide
DEVICE ADMINISTRATION 5.
To save your changes, click
Save and Restart
.
Uploading CA Certificate
This page allows a user to upload an X.509 CA (Certifying Authority) Certificate.
To upload a CA certificate:
1.
2.
3.
4.
5.
6.
Go to
Administration > X.509 CA Certificates
Click
Choose File
Click
Open
.
Once your file is selected, click
Import
.
.
and browse for your CA certificate file.
Your CA certificate file displays in the certificate list along with relevant details.
You may delete or remove a certificate by clicking the trash can icon to the right under
Options
.
Note:
It can take up to two minutes to add or remove a certificate. The changes are applied immediately and there is no need to restart the device after CA certificate is added or removed.
Setting up the Remote Management
To modify DeviceHQ automatic update settings, go to options under Your Device Remotely.
Auto-Update Settings
and refer to Managing
1.
2.
3.
4.
5.
6.
7.
Go to
Administration > Remote Management > Remote Server
. To allow the device to connect to the Remote Management Server, check
Enabled
.
If you want the device to use a secure connection, check
SSL Enabled
.
The
Server Name
field is pre-populated with the address of the Remote Management Server.
The
Server Port
field is pre-populated with the port the Remote Management Server listens on. You likely do not need to change this.
In the
Account Key
field, type the account key received from the Remote Management administrator.
The device is not allowed to connect to the Remote Management Server without a valid account key.
Click
Submit
.
To save your changes, click
Save and Restart
.
Managing Your Device Remotely
DeviceHQ can monitor devices, reboot devices, and perform remote software and configuration updates.
To configure your device to use DeviceHQ:
1.
2.
3.
Go to
Administration > Remote Management
Remote Server.
and check
Enabled
. See other options under Setting up the Go to options under
Auto-Update Settings
.
To define how often the device connects to DeviceHQ to check in and request any pending updates, set the
Check-In Interval
field to the desired number of minutes between 240-10080 (240 minutes to 1 week).
Note:
Your device must connect to DeviceHQ every 4 hours at a minimum. If you set the check-in interval to less than 4 hours, your change is ignored.
MultiConnect ® rCell 100 MTR-H6 User Guide 83
DEVICE ADMINISTRATION
84
4.
5.
To define how often the device connects to DeviceHQ to send GPS data, set the the desired number of minutes, between 240-10080 (240 minutes to 1 week).
do not have GPS. In this case, the system does not display this field.
GPS Data Interval Note:
field to Some MTR models If you want the device to connect to DeviceHQ only when the device's cellular link is up, check
Dial-On-Demand
.
Sync with
If
Sync with Dial-On-Demand
is checked and cellular dial-on-demand is enabled, the connection is not dialed solely for the purpose of connecting to DeviceHQ. The device will connect to the system only when other traffic brings up the link.
6.
7.
8.
9.
Check
Allow Firmware Upgrade
if you want DeviceHQ to make automatic updates of your firmware.
Check
Allow Configuration Upgrade
configuration software.
if you want DeviceHQ to make automatic updates of your Click
Submit
.
Click
Save and Restart
to save your changes.
Unavailable Services in PPP-IP Passthrough and Serial Modem Modes
In both
PPP-IP Passthrough
and
Serial Modem
modes, many rCell services described in this document are non configurable and therefore do not appear in the device configuration menu. If you choose one of these modes, all sections between this and the previous note on this subject are not available.
Notifications
The device can send alerts via email, SMS, and/or SNMP. To use these options, enable SMTP (see details), SMS (see
for details), and SNMP Traps (see
for details).
for A time stamp is added to the actual notifications. The format is
YYYY-MM-DD HH:MM
.
To setup notifications:
1.
2.
3.
4.
5.
6.
7.
Go to Under In the Click
Administration > Notifications > Configuration Recipient Group
, click
Create Recipient Group Add Phone
. Enter the person's Click
Add Email
. Enter the person's Add name, phone number and email for each person in your group. When done, click See the list of available alerts:
High Data Usage Add Group
(you must add a group before you can edit/save your alert).
Low Signal Strength Device Reboots
window, enter your
Group Name
.
Name
and
Ethernet Interface Failure Cellular Interface Failure Ethernet Data Traffic Cellular Data Traffic WAN Interface Failover
.
Name
and
Phone Number
. Then click
Finish
.
. Then click
Finish
.
Submit
.
MultiConnect ® rCell 100 MTR-H6 User Guide
DEVICE ADMINISTRATION 8.
Ping Failure Security Violation Flash Memory Violation Resource Overuse Wi-Fi Interface Failure* Wi-Fi Data Traffic* *
Only available on non-LTE devices Click on the pencil icon under the box appears for your chosen alert.
Edit
column for the alert you want to use and configure. The
Edit
dialog For
High Data Usage
:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Check
Enabled
.
Under
Data Plan Details
, select the
Custom Interval
.
Plan Type
from the drop down menu which includes
Monthly
or If you choose
Custom Interval
, enter the
Interval
length in days.
Select the
Start Date
from the calendar picker.
Enter the
Limit
in
MB
for data usage.
In
Notify At
, enter the percentage of the limit that triggers notification to be sent.
Select alert recipients from
Recipient Group
.
Select how you want to send alerts by clicking
,
SMS
, or
SNMP
.
Click
Finish
.
To save your changes, click
Save and Restart
.
For
Low Signal Strength
:
1.
2.
3.
4.
5.
6.
7.
8.
Check
Enabled
.
Enter the
Signal Threshold
in
dBm
.
Enter the
Duration
in seconds.
Under
Alerts
, select the recipients under
Recipient Group
.
In
Notify
, enter the frequency of notification (in hours). Default is
24
.
Select how you want to send alerts by clicking
,
SMS
, or
SNMP
.
Click
Finish
.
To save your changes, click
Save and Restart
.
For
Device Reboots
:
1.
2.
3.
4.
5.
6.
Check
Enabled
.
Under
Alerts
, select the recipients under
Recipient Group
.
In
Notify
, the field for frequency of notification is shown. The predefined value is modified by the user.
Select how you want to send alerts by clicking
,
SMS
, or
SNMP
.
Click
Finish
.
To save your changes, click
Save and Restart
.
Always
and cannot be For
Ethernet Interface Failure
: MultiConnect ® rCell 100 MTR-H6 User Guide 85
DEVICE ADMINISTRATION 1.
2.
3.
4.
5.
6.
7.
Check
Enabled
Enter the Under Click .
Duration
in seconds.
Notification Options
, select the recipients from the drop-down in In
Notify
, enter the frequency of notification (in hours). Default is Select how you want to send alerts by clicking
,
Finish
.
To save your changes, click For
Cellular Interface Failure
:
Save and Restart
.
24
.
SMS
or
SNMP
.
Recipient Group
.
1.
2.
3.
4.
5.
6.
7.
Check
Enabled
.
Enter the
Duration
in seconds.
Under
Notification Options
, select the recipients from the drop-down in
Recipient Group
.
In
Notify
, enter the frequency of notification (in hours). Default is
24
.
Select how you want to send alerts by clicking
,
SMS
or
SNMP
.
Click
Finish
.
To save your changes, click
Save and Restart
.
For
Ethernet Data Traffic
:
1.
2.
3.
4.
5.
6.
7.
Check
Enabled
Enter
Interval
In Click
Finish
.
.
in hours when alert is sent.
Under
Notification Options
, select the recipients from the drop-down in
Notify
, the constant value is To save your changes, click For
Cellular Data Traffic
:
Always
.
Select how you want to send alerts by clicking
,
Save and Restart
.
SMS
or
both
.
Recipient Group
.
1.
2.
3.
4.
5.
6.
7.
Check Enter Under In
Enabled Interval
.
in hours when alert is sent.
Notification Options
, select the recipients from the drop-down in
Notify
, the constant value is
Always
.
Select how you want to send alerts by clicking
, Click
Finish
.
To save your changes, click For
WAN Interface Failover
:
Save and Restart
.
SMS
or
both
.
Recipient Group
.
1.
2.
3.
4.
5.
6.
Check
Enabled
.
Enter the
Timeout
in seconds.
Select what to
Notify On
from the drop-down.
Under
Notification Options
, select the recipients from the drop-down in
Recipient Group
.
In
Notify
, the constant value is
Always
.
Select how you want to send alerts by clicking
,
SMS
or
SNMP
.
86 MultiConnect ® rCell 100 MTR-H6 User Guide
DEVICE ADMINISTRATION 7.
8.
Click
Finish
For
Ping Failure
: .
To save your changes, click
Save and Restart
.
For
Security Violation
:
1.
2.
3.
4.
5.
Check Under
Enabled
.
Notification Options
, select the recipients from the drop-down in In
Notify
, the constant value is
Always
.
Select how you want to send alerts by clicking
Email, SMS
Click
OK.
For
Flash Memory Violation
: , or
SNMP.
Recipient Group
.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
Check
Enabled
.
Under
Ping Details
, select the
Network Interface
from the drop-down.
Enter the
IP Address
or
URL
that you want to ping.
Enter the
Count
.
Enter the
Failure Threshold
.
Enter the
Ping Interval
.
Under
Notification Options
, select the recipients from the drop-down in
Recipient Group
.
In
Notify
, the constant value is
Always
.
Select how you want to send alerts by clicking
,
SMS
or
SNMP
.
Click
Finish
.
To save your changes, click
Save and Restart
.
Check
Enabled
.
Under
Notification Options
, select the recipients from the drop-down in
Recipient Group
.
In
Notify
, the constant value is
Always
.
Select how you want to send alerts by clicking
Email, SMS
, or
SNMP.
Click
OK.
For
Resource Overuse
:
1.
2.
3.
4.
5.
Check Under In
Enabled
.
Notification Options
, select the recipients from the drop-down in
Notify
, the constant value is
Always
.
Select how you want to send alerts by clicking Click
OK.
Email, SMS
, or
SNMP.
Recipient Group
.
The following notifications are only available on non-LTE devices: For
Wi-Fi Interface Failure
:
1.
2.
3.
Check
Enabled
.
Enter the
Duration
in seconds.
Under
Notification Options
, select the recipients from the drop-down in
Recipient Group
.
MultiConnect ® rCell 100 MTR-H6 User Guide 87
DEVICE ADMINISTRATION
88
4.
5.
6.
7.
In
Notify
, enter the frequency of notification (in hours). Default is Select how you want to send alerts by clicking Click
Finish
.
To save your changes, click For
Wi-Fi Data Traffic
:
Save and Restart
.
,
24
.
SMS
or
SNMP
.
1.
2.
3.
4.
5.
6.
7.
Check
Enabled
.
Enter
Interval
in hours when alert is sent.
Under
Notification Options
, select the recipients from the drop-down in
Recipient Group
.
In
Notify
, the constant value is
Always
.
Select how you want to send alerts by clicking
or
SMS
.
Click
Finish
.
To save your changes, click
Save and Restart
.
Customizing the User Interface
You can change how the user interface on your device appears. To change the interface:
1.
2.
3.
From the Navigation pane, select
Administration > Web UI Customization
.
To define what information appears on the
Customizing Support Information
.
Administration: Support
page, use the Support group. See To define other settings, use the
Device Settings
group. See
.
Customizing Support Information
To customize the interface displaying information that can be used to support users:
1.
2.
3.
To enable display of the custom support information, go to
Support Information
and check
Show Custom Info
.
Administration > Web UI Customization >
Type the desired information into the optional fields including:
Company Name Country Fax Address 1 Address 2 City State/ Prv Zip Code City
To add a phone number:
a.
b.
c.
Click
Add Phone
.
A label can appear next to the phone number, for example
Label
field, enter text that describes the phone number.
In the
Number
field, type the phone number.
Fax
or
Phone
or
International
. In the MultiConnect ® rCell 100 MTR-H6 User Guide
DEVICE ADMINISTRATION 4.
5.
6.
7.
8.
To add a link to a website, click
Add Link
.
a.
b.
c.
To label the website, type label text in In the
URL
To add an image, click
Upload Image: Label
field, type the website's link.
field.
To add further descriptive text about the site, type the information in the
Text
field.
a.
b.
Click
Browse
, go to the location of the image, and select the image.
Click
OK.
To delete an existing image, click
Remove Image
.
Click
Submit
.
To save your changes, click
Save and Restart
.
Specifying Device Settings
To define other custom settings for devices:
1.
2.
Go to
Administration > Web UI Customization > Device Settings
.
Enter desired information in the optional fields including:
Device Name Custom ID Button Color Button Font Color Highlight Color Highlight Font Color Note:
To define color fields, use
#rrggbb
format.
3.
To add a favorite icon, also known as a shortcut icon or bookmark icon, in the
Browse
to find where the Favicon file resides, select the desired file, and click
Custom Favicon Upload Icon
.
field, click
4.
5.
6.
7.
8.
To remove an existing favorite icon, click
Remove Icon
.
To add a custom logo, next to the select the desired file, and click
Custom Logo Upload Logo
.
field, click
Browse
to find where the logo file resides, To remove an existing logo, click
Remove Logo
.
Click
Submit
.
To save your changes, click
Save and Restart
.
Upgrading Firmware
Before upgrading
: reboot the device.
Upgrade the device's firmware to the latest version. You can download firmware upgrades from the MultiTech website or update your firmware automatically through MultiTech's DeviceHQ™ system.
For added security, you have the option to use higher. This authentication method prevents attempts to load invalid or damaged firmware files in order to defeat possible tampering. If you check this option, the module does not load any firmware that Multitech did not digitally sign.
Signed Firmware Validation
when upgrading from version 4.1 and MultiConnect ® rCell 100 MTR-H6 User Guide 89
DEVICE ADMINISTRATION
90 When downgrading to an older version of firmware or upgrading from versions lower than 4.1, you must uncheck this option.
If the
Signed Firmware Validation
is unchecked, the system runs an MD5 checksum automatically to check integrity of your target firmware file. If the MD5 checksum fails, the system generates an error saying the file integrity checks failed on the target file.
First, check your firmware version. Refer to the upper right corner of your configuration software window. To upgrade the firmware on your device:
1.
2.
3.
4.
5.
Before you upgrade your firmware, save your present configuration as a backup. Otherwise, see DeviceHQ .
Go to the MultiTech website, locate the firmware upgrade file you want for your device, and download this file to a known location.
Select
Administration
>
Firmware Upgrade
. The Administration: Firmware Upgrade pane opens.
If you want further validation of your upgrade file, you can check automatically runs an MD5 checksum.)
Signed Firmware Validation
option (checked by default). This works for upgrading from versions 4.1 or higher. (If unchecked, the system Click the
Choose Firmware Upgrade File
button:
a.
b.
Click
Browse
to find where the firmware file resides that you want to apply.
Select the file and click
Open
. The file name appears next to the
Choose Firmware Upgrade File
button. Make sure you select the correct BIN file; otherwise, your device can become inoperable.
6.
7.
8.
Note:
Click
Start Upgrade
.
A message about time needed to upgrade appears. Click
OK
. A progress bar appears indicating the status of the upgrade. When upgrade is completed, your device reboots.
After the firmware upgrade is complete, verify your configuration to make sure it is what you expected.
The new firmware is written into flash memory.
It may take up to 10 minutes to upgrade the firmware. Do not interfere with the devices's power or press the reset button during this time.
The DeviceHQ is a cloud platform that provides the ability to remotely manage and upgrade devices.
Please see the
Remote Management
section or visit www.devicehq.com
for more information.
Saving and Restoring Settings
To restore previous configuration settings to your device, to restore settings to their factory defaults, or to save the current configuration:
1.
2.
Go to
Administration > Save/Restore > Upload Configuration
.
To restore a configuration from a previously saved file, go to
Restore Configuration From File
:
a.
b.
c.
Next to the Navigate to the location where the configuration file is stored and select the desired file.
Click
Restore Configuration Restore
. The device reboots.
field, click
Browse
.
3.
To save your current configuration to a file, go to
Save Configuration To File
:
a.
Click
Save
.
MultiConnect ® rCell 100 MTR-H6 User Guide
DEVICE ADMINISTRATION 4.
5.
6.
7.
b.
Navigate to the location where you wish to save the file and select location.
This option is only available if you had reset to user-defined configuration. (Also, holding the reset button on the device for 30 seconds overrides user-defined settings and resets to factory default.) To reset the device's configuration to the factory settings, go to
Reset to Factory Default Configuration
:
a.
b.
c.
Click Click
Reset OK
.
.
A dialog box appears prompting you to confirm that you want to restore to factory default settings.
This option is only available if you set user-defined settings first. (Also, holding the reset button on the device for 5 seconds sets user-defined defaults) To restore the device's configuration to the user-defined configuration settings, go to
Reset to User-Defined Configuration
:
a.
b.
c.
To set deployment-specific default settings, click
Set Current Configuration As User-Defined Default
.
a.
b.
Click
Restore
.
A dialog box appears prompting you to confirm that you want to restore to a set of user-defined settings.
Click
OK
settings.
Click
OK
.
.
A dialog box appears prompting you to confirm that you want to restore to a set of user-defined To save a current configuration:
a.
b.
c.
d.
Click
Save
.
A dialog box appears asking you if you want to open or save the configuration file. Click Navigate to the location where you want to store the configuration. Click
Save
.
A progress dialog box appears to indicate that the configuration is being saved. Click
Save
.
Close
.
Using the Debugging Options
The device has utilities to help troubleshoot and solve technical problems. You can set up your device: To automatically reboot itself at a particular time of day or use a particular offset in hours from boot.
To record and report Syslog messages that can help you resolve potential issues with your device.
You can also communicate directly with the device's cellular radio. To do this:
1.
2.
3.
From
Administration
, select
Debug Options
.
Click the down arrow to the far right of the Radio Terminal screen to view the terminal window.
Enter AT commands to the radio.
See also:
Statistics Configuration Fields
Automatically rebooting the device
To specify the amount of time that passes before the device automatically reboots itself:
1.
Go
Administration > Debug Options > Auto Reboot Timer
, select from the drop-down list under
Auto Reboot
.
DISABLED
,
HOUR OF DAY
, and
TIMER
MultiConnect ® rCell 100 MTR-H6 User Guide 91
DEVICE ADMINISTRATION 2.
3.
In the
Auto Reboot Timer Restart
(0-23).
field, select the
Hour of the Day
(0-23) and then enter
Hour of the Day to
If you do NOT want the device to automatically reboot, set the time to
0
. The default setting is
0
.
Setting up Telnet
To enable and configure Telnet on your device:
1.
2.
3.
4.
5.
6.
Go to
Administration > Debug Options > Telnet
, check
Enabled
.
Enter the
Port
number for Telnet.
Enter the
Username
.
Enter the
Password
. Enter it again under
Confirm Password
.
Click
Submit
.
To save your settings, click
Save and Restart
.
Configuring Remote Syslog
To enable and configure Remote Syslog to capture and send log data from your device, you must have local syslog software installed.
To set up a log request in DeviceHQ, under
Devices
, select your device. Then click on Tasks and select
Device Logs
. After the request has been completed, return to the device administration software.
Request 1.
2.
3.
4.
5.
6.
To activate
Enabled
.
Remote Syslog
, go to
Administration > Debug Options > Logging
under
Remote Syslog
, check To enable a remote server to receive and store the device's log data, in the address of the desired server.
IP Address
field, type the IP To determine the amount of log information that is collected, in the information from the values in the dropdown menu which includes:
Debug,
and
Maximum Minimum, Error, Warning, Info,
. The system will collect the type of information you specify. For example,
Maximum
will collect all the log data available while above that level.
Warning Debug Log Level
, select the type of will collect anything that is a warning or To download syslog information directly from the device, click
Download
.
Click
Submit
.
To save your changes, click
Save and Restart
.
Statistics Settings
To configure
Statistics
:
1.
2.
3.
4.
5.
6.
7.
Go to
Administration > Debug Options > Statistics
.
Enter the
Save Timeout
in seconds.
Enter the
Save Data Limit
in megabytes.
To delete cell activity history, click
Delete Cellular History
.
To delete ethernet history, click
Delete Ethernet History
.
Click
Submit
.
To save your settings, click
Save and Restart
.
92 MultiConnect ® rCell 100 MTR-H6 User Guide
DEVICE ADMINISTRATION
Ping and Reset Options
Perform a Ping Test
Ping allows you to test the IP address or URL to ensure it is operational.
To perform a ping test:
1.
2.
3.
4.
Go to
Administration > Debug Options > Ping
.
Enter the
IP address or URL
of the site you wish to ping.
Under
Network Interface
, choose from the available drop-down list options including:
CELLULAR,
and
ETHERNET
.
ANY, LAN,
Click
Reset Options Ping
.
To reset the modem, go to
Administration > Debug Options > Reset Options
, click system displays a message confirming a successful reset.
Reset Modem.
If successful, the
Usage Policy
The device shall provide a Usage Policy for the system. The default usage policy reads as follows:
This system is for the use of authorized users only. Individuals using this system without authority, or in excess of their authority, are subject to having all their activities on this system monitored and recorded by system personnel.
Anyone using this system expressly consents to such monitoring and is advised that if such monitoring reveals possible evidence of criminal activity, system personnel may provide the evidence of such monitoring to law enforcement officials.
This policy displays on the login page. You may modify or add language to the policy as needed.
To view or modify the
Usage Policy
:
1.
2.
3.
4.
Go to
Administration > Usage Policy
The default language appears. You may edit the language directly in the text box.
When completed, click
Submit
.
To save your changes, click .
Save and Restart
.
If at any time you want to return the device to the default setting, click the right corner. (This reverts the
Usage Policy
back to the default language.)
Reset to Default
button in the bottom MultiConnect ® rCell 100 MTR-H6 User Guide 93
DEVICE STATUS
Chapter 13 – Device Status Viewing Device Statistics
The device collects sent/received traffic data for WAN, Cellular, and Ethernet networks. The daily statistical data is stored on the device for a 365-day period. All data that is older than 365 days is automatically deleted.
1.
2.
From
Status & Logs PPP-IP Passthrough
on the left side of the Web Management interface, select mode, go to
Status
menu and then
Statistics
.)
Statistics
. (If you select The application categorizes statistics about your device. To see statistics that appear in a particular category, click the appropriate tab.
System Ethernet Wi-Fi Access Point Cellular Serial Bluetooth GRE IPSec OpenVPN Definitions
A data usage bar chart and a cumulative usage line chart are available for Ethernet, Wi-Fi, and Cellular. The Data Usage bar chart also shows statistics for data sent and data received. The following list includes some definitions to help you understand some of the data. Not all of the available statistics are listed here or shown in every tab.
Total
: Total number of sent/received bytes for a 365-day period.
Today
: Total number of sent/received bytes for today.
Sessions
: Bytes
Packets
: Number of successfully transmitted (TX) and received (RX) packets.
Errors
: Number of errors that occurred. Possibly due to connection issues or network congestion.
Dropped
: Number of dropped packets. Possibly due to memory constraints.
Overruns
: Number of overruns that occurred. Possibly due to processing constraints.
Frame
: Number of invalid packets.
Carrier
: Number of signal modulation errors that occurred (possibly due to physical connection).
Collisions
: Number of packet collisions that occurred due to network congestion.
Queue Length
: Length of the transmit queue.
Cumulative and Daily Usage
Click
Show Cumulative Usage
for 30-day period.
or
Show Daily Usage
to display the desired view. Default chart view is Daily Usage
Timeframe of Chart
94 MultiConnect ® rCell 100 MTR-H6 User Guide
DEVICE STATUS
Change the time frame for the chart by clicking
Start Date
or
End Date
using calendar to set a different date.
Show Log
The associated run-time logs for this section.
Mail Log
Mail Log
shows the recent email delivery attempts and the mail log details. Mail log entries are sorted by date with the most recent on top. (This function is not available if you use
PPP-IP Passthrough
or
Serial Modem
mode). You can select the number of emails to display in the queue. Possible values are
5, 10, 25, 50
, or
All emails
.
1.
2.
3.
Go to
Status & Logs > Mail Log
to display the
Mail Log
window.
To see the delivery details, click the eye icon under
Options
for the desired email entry.
To delete all mail log entries, click
Note: Purge Log
.
Logs do not persist through power cycles.
Mail Queue
Mail Queue
shows the emails that are waiting to be sent. The most recent email delivery attempts are on top. You can select the number of emails to display in the queue. Possible values are
5, 10, 25, 50
, and
All emails
. (This function is not available if you use power cycles.
PPP-IP Passthrough
or
Serial Modem
mode). Note: Logs do not persist through
1.
2.
Go to
Status & Logs > Mail Queue
To view the delivery details for an individual email, click the eye icon under email entry.
to display the
Mail Queue
window.
Options
for the desired
RF Survey
RF survey is not available for LTE models.
If you have a non-LTE device with a SIM card and want to perform an RF Survey, enter this address: 192.168.2.1/rf_survey and follow the instructions below. (The link uses the default IP address for the device upon log in. If you change the IP address of the device, make sure to use that new IP address in the link).
After the RF Survey, you must reset the device in order to restore cellular radio functionality.
The RF Survey tool allows you to view the list of the cell towers that belong to the carrier and their signal quality details such as Signal Level and Signal Noise Ratio. You need a SIM card to acquire the list of available cell towers.
Note:
Selecting this tool terminates any existing PPP connection
1.
2.
Enter this address: 192.168.2.1/rf_survey to open the
RF Survey
page.
The search for the cell towers takes up to 2 minutes. The wait icon displays while the search is in progress.
The cell tower to which the router is currently connected displays at the top of the list.
To view the Signal Strength chart of a carrier, under
Options
, click the eye icon for the carrier.
The
Carrier Details
window appears.
This feature helps you decide which area has better signal strength and thus a better location for the router.
MultiConnect ® rCell 100 MTR-H6 User Guide 95
DEVICE STATUS 3.
After the RF survey, reset your device. Go to
Commands > Restart Device
.
Service Statistics
On the Web Management interface side menu, click
Status & Logs > Services
to display the
Service Statistics
window. (If you use
PPP-IP Passthrough
mode, go to
Status
menu and follow the remaining instructions.) This window shows the configuration (enabled or disabled) and the status of the following services:
DDNS SNTP Cellular RTC TCP/ICMP Keep Alive Dial-on-Demand SMTP SMS Failover
Statistics Configuration Fields
The device saves the statistics periodically depending on the configured timeout and data limit. By default, the Save Timeout is set to 300 seconds and the Data Limit is set to 5 MB. For the default scenario, the device saves the data if more than 5 minutes has elapsed, or if more than 5 MB has been sent or received from the last check. The device checks these conditions every minute, but the data is saved only if one of the conditions is met.
Field
Save Timeout Save Data Limit Delete Cellular History Delete Ethernet History
Description
The device saves the statistical data when the desired timeout period has elapsed. Default is 300 seconds (5 minutes).
The device saves the statistical data if the data limit is reached. Default is 5 MB.
Deletes all Cellular history on the device.
Deletes all Ethernet history on the device.
Notifications Sent
This page displays attempts to send Notifications via email, SMS, or SNMP.
The list includes the following details of each attempted notification: attempted.
Date, Message, Recipient Group
, and the status of the notification under each communication method including success via that method. An
X Email, SMS
, and
SNMP
. A check indicates means failure. No symbol or a blank space indicates that method was not To view
Notifications Sent
:
1.
2.
3.
Go to
Status & Logs > Notifications Sent
.
In the upper right corner, click
Refresh
to update the list.
To the right of
Refresh
, click
Delete All Notifications
if you want to remove all items in the list.
96 MultiConnect ® rCell 100 MTR-H6 User Guide
: REGULATORY INFORMATION
Chapter 14 – : Regulatory Information 47 CFR Part 15 Regulation Class B Devices
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Warning:
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Industry Canada Class B Notice
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Reglement Canadien sur le matériel brouilleur.
This device complies with Industry Canada license-exempt RSS standard(s). The operation is permitted for the following two conditions:
1.
2.
the device may not cause interference, and this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes:
1.
2.
l'appareil ne doit pas produire de brouillage, et l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
FCC Interference Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1.
2.
This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation.
MultiConnect ® rCell 100 MTR-H6 User Guide 97
: REGULATORY INFORMATION
FCC and IC Antenna Requirements Toward License Exempt Radio Transmitters (Bluetooth/WLAN)
The license-exempt Bluetooth/WLAN radio transmitter contained in this equipment may only be operated with an antenna of a type, a maximum gain and the required antenna impedance as approved and specified below. To reduce potential radio interference to other users, choose the antenna type and it's gain so that the equivalent isotropically radiated power (EIRP) is not more than that necessary for successful communication.
Requirements for Cellular Antennas with regard to FCC/IC Compliance
There cannot be any alteration to the authorized antenna system. The antenna system must maintain the same specifications. The antenna must be the same type, with similar in-band and out-of-band radiation patterns. This device has been designed to operate with the antennas listed below and having a maximum gain for 850 Mhz of <= 6.4 dBi , for 1700 Mhz of <= 6.5 dBi, and for 1900 Mhz of <= 3 dBi. Antennas not included in this list or that have a gain greater than specified are strictly prohibited for use with this device. The required antenna impedance is 50 ohms.
EMC, Safety, and Radio Equipment Directive (RED) Compliance
The CE mark is affixed to this product to confirm compliance with the following European Community Directives: Council Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment; and Council Directive 2014/53/EU on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity.
MultiTech declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The declaration of conformity may be requested at https://support.multitech.com
.
Restriction of the Use of Hazardous Substances (RoHS)
98
Multi-Tech Systems, Inc.
Certificate of Compliance 2011/65/EU
Multi-Tech Systems, Inc. confirms that its embedded products comply with the chemical concentration limitations set forth in the directive 2011/65/EU of the European Parliament (Restriction of the use of certain Hazardous Substances in electrical and electronic equipment - RoHS).
These MultiTech products do not contain the following banned chemicals 1 : Lead, [Pb] < 1000 PPM MultiConnect ® rCell 100 MTR-H6 User Guide
: REGULATORY INFORMATION
Mercury, [Hg] < 1000 PPM Hexavalent Chromium, [Cr+6] < 1000 PPM Cadmium, [Cd] < 100 PPM Polybrominated Biphenyl, [PBB] < 1000 PPM Polybrominated Diphenyl Ether, [PBDE] < 1000 PPM Environmental considerations: Moisture Sensitivity Level (MSL) =1 Maximum Soldering temperature = 260C (in SMT reflow oven) 1 Lead usage in some components is exempted by the following RoHS annex, therefore higher lead concentration would be found in some modules (>1000 PPM); - Resistors containing lead in a glass or ceramic matrix compound.
REACH Statement
Registration of Substances
After careful review of the legislation and specifically the definition of an “article” as defined in EC Regulation 1907/2006, Title II, Chapter 1, Article 7.1(a)(b), it is our current view that Multi-Tech Systems, Inc. products would be considered as “articles.” In light of the definition in § 7.1(b) which requires registration of an article only if it contains a regulated substance that “is intended to be released under normal or reasonably foreseeable conditions of use,” our analysis is that Multi-Tech Systems, Inc. products constitute nonregisterable articles for their intended and anticipated use.
Substances of Very High Concern (SVHC)
Per the candidate list of Substances of Very High Concern (SVHC) published October 28, 2008 we have reviewed these substances and certify the Multi-Tech Systems, Inc. products are compliant per the EU “REACH” requirements of less than 0.1% (w/w) for each substance. If new SVHC candidates are published by the European Chemicals Agency, and relevant substances have been confirmed to be greater than 0.1% (w/w), Multi-Tech Systems, Inc. will provide updated compliance status.
Multi-Tech Systems, Inc. also declares it has been duly diligent in ensuring that the products supplied are compliant through a formalized process which includes collection and validation of materials declarations and selective materials analysis where appropriate. This data is controlled as part of a formal quality system and will be made available upon request.
Waste Electrical and Electronic Equipment Statement
WEEE Directive
The WEEE Directive places an obligation on EU-based manufacturers, distributors, retailers, and importers to take back electronics products at the end of their useful life. A sister directive, ROHS (Restriction of Hazardous Substances) complements the WEEE Directive by banning the presence of specific hazardous substances in the products at the design phase. The WEEE Directive covers all MultiTech products imported into the EU as of August 13, 2005. EU-based manufacturers, distributors, retailers and importers are obliged to finance the costs of recovery from municipal collection points, reuse, and recycling of specified percentages per the WEEE requirements.
MultiConnect ® rCell 100 MTR-H6 User Guide 99
: REGULATORY INFORMATION
Instructions for Disposal of WEEE by Users in the European Union
The symbol shown below is on the product or on its packaging, which indicates that this product must not be disposed of with other waste. Instead, it is the user's responsibility to dispose of their waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or where you purchased the product.
July, 2005 100 MultiConnect ® rCell 100 MTR-H6 User Guide
: REGULATORY INFORMATION
Information on HS/TS Substances According to Chinese Standards
In accordance with China's Administrative Measures on the Control of Pollution Caused by Electronic Information Products (EIP) # 39, also known as China RoHS, the following information is provided regarding the names and concentration levels of Toxic Substances (TS) or Hazardous Substances (HS) which may be contained in Multi-Tech Systems Inc. products relative to the EIP standards set by China's Ministry of Information Industry (MII).
Hazardous/Toxic Substance/Elements Name of the Component
Printed Circuit Boards Resistors Capacitors Ferrite Beads Relays/Opticals ICs Diodes/ Transistors Oscillators and Crystals Regulator Voltage Sensor Transformer Speaker Connectors LEDs Screws, Nuts, and other Hardware AC-DC Power Supplies Software /Documentation CDs Booklets and Paperwork Chassis O O O O O O O O O O O O O O O O O O O O X X O O O O X O O O O O O X
Lead (PB)
O O O O
Mercury (Hg)
O O O O O O O O O O O O O O O O O O O
Cadmium (CD) Hexavalent Chromium (CR6+)
O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O
Polybromi nated Biphenyl (PBB)
O O O
Polybrominat ed Diphenyl Ether (PBDE)
O O O O O O O O O O O O O O O O O O O
X
material of such component is higher than the SJ/Txxx-2006 Requirements for Concentration Limits.
O
Represents that the concentration of such hazardous/toxic substance in all the units of homogeneous Represents that no such substances are used or that the concentration is within the aforementioned limits.
MultiConnect ® rCell 100 MTR-H6 User Guide 101
: REGULATORY INFORMATION
Information on HS/TS Substances According to Chinese Standards (in Chinese)
依 照中 标准 有毒 物质 息 根据中华人民共和国信息产业部 控制管理办法》(第 39 (MII) 制定的电子信息产品 (EIP) 号),也称作中国 RoHS, 下表列出了 标准-中华人民共和国《电子信息产品污染 Multi-Tech Systems, Inc.
产品中可能含有的有毒 物质 (TS) 或有害物质 (HS) 的名称及含量水平方面的信息。 有 害 // 有 物质 // 元 素 成 分名 印刷电路板 电阻器 电容器 铁氧体磁环 继电器 / 光学部件 ICs 二极管 / 晶体管 振荡器和晶振 调节器 电压传感器 变压器 扬声器 连接器 LEDs 螺丝、螺母以及其它五金件 交流 直流电源 软件 / 文档 CD 手册和纸页 底盘 O O O O O O O O O O O O O O O O O O O O X X O O O O X O O O O O O O O O X O 铅
(PB)
汞
(Hg)
O O O O O O O O O O O O O O O O O O O
(CD)
O O O O O O O O O O O O O O O O O 六 铬
(CR6+)
多 溴联
(PBB)
O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O 多 溴二 醚
(PBDE)
O O
X O
表示所有使用类似材料的设备中有害 / 有毒物质的含量水平高于 表示不含该物质或者该物质的含量水平在上述限量要求之内。 SJ/Txxx-2006 限量要求。 102 MultiConnect ® rCell 100 MTR-H6 User Guide
Scarica
Pubblicità