Digital Watchdog DW-DTLA500 SiteWatch™ 1640ft (500m) Laser surveillance sensor User's Manual


Add to my manuals
19 Pages

advertisement

Digital Watchdog DW-DTLA500 SiteWatch™ 1640ft (500m) Laser surveillance sensor User's Manual | Manualzz

SiteWatch™ laser sensor

DW-DTLA500

User’s Manual

Ver. 09/19

Before installing and using the camera, please read this manual carefully.

Be sure to keep it handy for future reference.

Safety Information

BEFORE OPERATION

This section of the manual uses the following warning symbols to provide information regarding use of the product to prevent you and others from being harmed and your product from being damaged. These warning symbols are described below. Ensure you understand these precautions before proceeding with the installation.

Warning Caution

Failure to follow the instructions provided by this warning and improper handling may cause death or serious injury Failure to follow the instructions provided by this caution and improper handling may cause injury and/or property damage This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

This symbol requires an ac tion or gives an instruction.

Warning

Never attempt to disassemble or repair the product. It may cause fire or damage to the devices.

Hold the main unit securely when you install or service it. Exercise care not to bump the product against nearby objects or drop it inadvertently.

Caution

Only use approved Power over Ethernet power supplies.

Never try to power the device other than with the RJ45 PoE connection.

Do not touch the unit connections with a wet hand or when the product is wet from rain. It may cause a short circuit and damage the unit.

Clean and check the products periodically for safe use. If any problem is found, contact DW product.

® or authorized partners to solve the issue before continuing to use the This product is intended to detect people and is not designed to prevent theft, disasters or accidents. The manufacturer shall not be held liable for any damage to user’s property resulting from theft, disasters or accidents.

Contents

INTRODUCTION

04 Specifications 05 Before operation 05 05 06 Part identification Preparing to mount the laser sensor Cabling the laser sensor

INSTALLATION AND DETECTION METHODS

06 Detection methods 06 06 06 Perimeter detection Spot surveillance Change detection

OPERATION PRINCIPLES

07 Sensor placement 07 07 Laser divergence Multiple reflections 08 09 Alarm zones Combining SiteWatch™ laser sensor with cameras

INSTALLATION AND ANGLE ADJUSTMENT

10 Alignment 10 Hardware reset

USER INTERFACE

11 Factory default settings 11 Login 11 Installation and configuration 11 Alignment 12 13 14 Device configuration Import and export settings Firmware update

ALARM SETTINGS

15 Alarm settings 15 Zone alarms 16 17 Alarm zones actions Reference point 18 Timer/Heartbeat 19 Weather alarm 19 Logout

20 WARRANTY 21 LIMITS AND EXCLUSIONS

Introduction

The DW-DTLA500 is a laser surveillance sensor that allows the user to monitor and locate intrusions for applications where physical fences are not desirable, possible or where enhanced security is required. The 1640ft (500m) sensor works without reflectors and reacts in fractions of a second. The DW-DTLA500 SiteWatch™ sensor knows the exact position of an object and offers adaptive alarm settings. For example, the sensor can be set to react to cars only in a specific lane and alarm if an object has stopped or if a door opens, while ignoring all other activities.

1.1. SPECIFICATIONS

FIELD OF APPLICATION ALARM ZONES ALARM ACTIONS SELF AWARENESS DETECTION RANGE DETECTION RESOLUTION UPDATE RATE LASER WAVELENGTH BEAM DIVERGENCE ALIGNMENT LASER LASER CLASS POWER SUPPLY POWER CONSUMPTION OPERATING TEMPERATURE INTERFACE RELAY SWITCH MOUNTING ENCLOSURE RATING COLOR WEIGHT Warranty Outdoor surveillance and monitoring Up to 20 fully adaptable zones, each zone has individual alarm sensitivity settings and alarm actions.

Network alarm, relay. Easy direct integration with IP to VMS, enabling PTZ control, automatic video recording and object position.

Adaptive digital processing algorithm suppresses noise from fog and snow, and detects challenging weather to allow alarms to VMS.

0 - 1640ft (500m) +/- 1 dm 250 Hz 905nm 2.0 x 2.0 mRad Yes Class 2 laser product, eye-safe Power over Ethernet (48V DC) or 12 V DC 4W (PoE class 2) -22°F to +140°F (-30°C to +60°C) Ethernet IEEE 802. 3af, TCP/IP, web browser user interface Max 30V 200mA, NC and NO 4 x M5 - Bosch compatible 2.87” x 1.61” (73 x 41mm) 4 x M5 - Axis compatible 1.57” x 2.44” (40 x 62mm) 2 x M6 - common standard 2.87” (73mm C-C) 5/8”-11 UNC (tripod mount) IP66 Shell: gray, sensor: black 2.4Kg

1 year warranty

1.2. BEFORE OPERATION

The SiteWatch™ laser sensor is designed to be intuitive and easy to use. To ensure best performance, all users should read this instruction manual carefully before use.

4

Precautions

1.3. PART IDENTIFICATION

Shell screw (Countersunk M4x6 mm) Main unit Shell Cable gland Service lid

NOTE:

The sensor must always be mounted on a steady foundation, such as a wall or a pole that is well secured to minimize risk of misalignment due to vibrations.

NOTE:

The sensor has a maximum detection range of up to 1640.42ft (500m). Recommended range for demanding applications is 984.25ft (300m) to ensure detection of small objects such as people, even in difficult weather conditions. Service lid screw (M3x8 mm)

1.4. PREPARING TO MOUNT THE LASER SENSOR

1. Do not stare directly into the red alignment laser. Do not leave the red alignment laser turned on after installation process is complete. 2. Use wall brackets and tripod with compatible mounting only.

3. Install the product on a solid surface. 4. Install the product so that the detection line is not obscured by interference from tall grass or tree branches waving in the wind.

5. For perimeter protection, the unit should be placed at an optional detection height and parallel to ground.

6. Do not install or leave the product in a location exposed to heat, vibration or impact. 7. The SiteWatch™ laser sensor is compatible with a number of conventional wall brackets used for surveillance cameras, all standard accessories, such as pole mounts, corner mounts etc., can be used. 8. When using the product for mobile applications, the threaded UNC 5/8” - 11 hole is compatible with most surveyor tripods. 9. Using the mounting accessory, mark and drill all necessary holes in the mounting surface.

1.5. CABLING THE LASER SENSOR

The SiteWatch™ laser sensor is powered with PoE and all communication is made with TCP/IP. For applications that require cables over 328ft (100m) between unit location and nearest switch or router it is necessary to use network extenders or fiber optics. 1. Remove the shell and service lid.

2. Insert the network cable without a connector through the cable gland. Crimp RJ45 connector to the cable then plug into the RJ45 jack.

Power input

Power over Ethernet (48V DC) or 12V DC

Power consumption

4W, class 2 3. Tighten the cable gland to secure the cable and seal the casing. 4. If the relay is desired to be used, replace the plug on the backside with supplied cable gland. 5. Connect the signal cable to the terminals. Choose connection for desired function, normally open (N/O) or normally closed (N/C). 6. Replace the service lid and shell.

5

Installation

2. INSTALLATION AND DETECTION METHODS 2.1. Detection methods

With fully adaptable alarm zones, the sensor has many detection methods customizable to any application. Below are three typical applications.

2.1.1. Perimeter detection

The sensor is used to detect all objects crossing the virtual fence. Zones can be created along the line of sight to permit different actions based on object location. For these types of applications, the sensor should be placed at the optimal detection height and aligned with the ground. SiteWatch™ sensor SiteWatch™ sensor SiteWatch™ sensor

2.1.2. Spot surveillance

Detection is only desired in a specific area (a part of a road, an entrance to a house or along a wall). In these applications, the sensor can be located anywhere with a clear line of sight to the detection area. SiteWatch™ sensor

2.1.3. Change detection

The sensor is used to detect if an object moves. In these applications, the sensor can be located anywhere with a clear line of sight to the object. 6

Operation Principles

3. OPERATION PRINCIPLES 3.1. Sensor placement

The sensor has a maximum detection range of 1640ft (500m). The recommended range for demanding applications is 984ft (300m), to ensure detection of small objects such as humans, even in difficult weather conditions. There are two ways to create a continuous virtual fence with the sensors. 1. They can be placed 984ft (300m) apart and have an overlapping detection area as shown in figure A. Sensor placement type A is recommended to get highest security level. With the overlapping detection areas, the sensors cover each other. 2. They can be placed in pairs, with 1968.5ft (600m) between each pair, as shown in figure B. Sensor placement type B allows for lower installation expense, with fewer points needing network connection. However, it can create a weak point at the sensor’s locations.

NOTE:

When placing the SiteWatch™ laser sensors opposite each other (as shown in B below), make sure the lasers are crossed and not aimed directly at each other.

A

SiteWatch™ sensor SiteWatch™ sensor 984ft (300m) SiteWatch™ sensor SiteWatch™ sensor

B

SiteWatch™ sensor SiteWatch™ sensor SiteWatch™ sensor SiteWatch™ sensor 1968.5ft (600m)

3.2. Laser divergence

The laser has a beam divergence of 2.0x0.2 m Rad. It spreads more in height than in width. This means that the laser beam is approximately 1 x 0.1m at a distance of 1640ft (500m).

SiteWatch™ sensor 3.28ft (1m) 1640ft (500m) SiteWatch™ sensor SiteWatch™ sensor 984ft (300m) SiteWatch™ sensor SiteWatch™ sensor SiteWatch™ sensor SiteWatch™ sensor 984ft (300m) SiteWatch™ sensor SiteWatch™ sensor

3.3. Multiple reflections

As the laser beam diverges, it is possible for the beam to hit multiple targets. Each target will cause a reflection back to the sensor. The sensor’s algorithm analyzes the different reflections and calculates the distance to the object. If it is more than 16.4ft (5m) between the objects, the sensor will only use measurements from the far object to calculate the object position. If for example, a tree branch partly covers the sensor’s line of sight. The laser may still be able to detect objects behind it. It is, however, strongly recommended to ensure that the sensor’s line of sight is clear to maintain the highest performance.

Calculated distance SiteWatch™ sensor 16.4ft (5m) 7

Operation Principles

If it is less than 16.4ft (5m) between the objects, the sensor will cluster the objects and use a weighted averaging to calculate a virtual object position. If each object gets 50% of the laser beam, the calculated distance will be in the middle between the objects. If the first object gets 75% and the other 25%, the calculated dis tance will move closer to the first object.

Calculated distance SiteWatch™ sensor > 16.4ft (5m) Calculated distance SiteWatch™ sensor > 16.4ft (5m) Calculated distance SiteWatch™ sensor > 16.4ft (5m)

3.4. Alarm zones

Users can set up 20 separate alarm zones. Each zone has individual start- and stop-distance, alarm sensitivity and alarm action.

SiteWatch™ sensor Using all 20 zones can make it possible to have unique alarms for each 82ft (25m) sections of the sensor’s perimeter if the zones are equally distributed. The sensor is also able to send the exact intrusion distance for even more accurate location. In most cases, it is not recommended to have the zones equally distributed – it is better to set the zones to match the surrounding area.

For example, if the detection area includes a crossing road, it is useful to create zones to match the road, as seen in the example below.

SiteWatch™ sensor Each zone in the SiteWatch™ laser sensor has an individual start- and stop-distance. This means the zones can overlap in any way. It also means that only areas of interest will create alarms. It is also possible to have different alarm sensi tivity for each zone, allowing for additional fine-tuning of the system.

SiteWatch™ sensor Zone B Zone A Zone C Zone D 8

Combining the laser sensor with IP cameras

3.5. Combining the SiteWatch™ laser sensor with surveillance cameras

The SiteWatch™ laser sensor is designed to detect objects and alarm to a VMS software such as DW Spectrum® IPVMS, or directly to an IP camera. With a dedicated detector, fewer cameras can be used since they can be programmed to the exact location of an intrusion. The number of cameras required depends on camera type. Pan tilt-zoom (PTZ) and multi-sensor cameras are recommended to use in combination with the SiteWatch™ laser sensor, but fixed and vari-focal cameras can also be used. We recommend using fixed and vari-focal cameras for high-interest locations, such as gates and entrances, and PTZ cameras for the rest of the area.

SiteWatch™ sensor

Multi-sensor

camera

Multi-sensor

camera SiteWatch™ sensor

PTZ

camera SiteWatch™ sensor

Fixed

camera

Fixed

camera

PTZ

camera

Fixed

camera 9

Combining the laser sensor with IP cameras

4. INSTALLATION AND ANGLE ADJUSTMENT 4.1. Alignment

The final alignment adjustment of the sensor is made with the adjustment screws on the side of the sensor. To facilitate the alignment, horizontal and vertical adjustments must be completed separately.

Vertical Alignment Adjustment Horizontal Alignment Adjustment To align the sensor: 1. Remove the sensor’s shell.

2. Fasten the telescopic sight (optional) with the quick release mounts.

3. Release all adjustment screws using the included 2.5mm hex Allen wrench.

4. Use the screw on one side to push the sensor in the desired direction. 3/4 turns of the adjustment screws are equal to 3.28ft (1m) movement at 328ft (100m), 6.56ft (2m) at 656ft (200m) and so on. 5. When the sensor is aligned, tighten the screws from both sides to lock the alignment into place. 6. Confirm that alignment is correct once all the screws have been tightened. 7. Replace the sensor’s shell.

4.2. Hardware reset

1. Remove the sensor’s shell and service lid.

2. Disconnect the network cable.

3. Press and hold the reset button, while reconnecting the network cable back.

4. Replace the sensor’s service lid and shell.

5. The unit will change its IP address back to the default IP address. 6. When accessing the unit using the web-based user interface, it will load the bootloader screen. 7. If there is any issue with the firmware, please restore factory firmware by pressing ‘Restore factory firmware’.

8. Press ‘Start firmware’ to restart the unit with the factory default IP address and login.

Reset button 10

Web interface - Login

5. USER INTERFACE

All settings to the sensor can be made through the web-based user interface. The instructions for the web-based user interface described below are valid for firmware 1.8 and higher.

5.1. FACTORY DEFAULT SETTINGS

When using the sensor for the first time, or if a factory reset has been made, the following settings are used:

Default IP address:

192.168.0.10

Default username: Default password:

admin admin

5.2. LOGIN

1. Open a web browser.

2. 3. 4. In the address field, type in the sensor’s IP address. The web-based user interface login page will be shown. Enter your username and password to access the sensor’s settings.

5.3. INSTALLATION AND CONFIGURATION 5.3.1. Alignment

1. Alignment is the default tab shown when logging into the sensor. 2. Turn on and off the alignment laser with the buttons on the bottom right. Remember to turn off the laser when the installation process is complete. 3. The two diagrams on this page show live data from the sensor. The upper diagram shows data from the last 10 seconds. The second data from the last 60 seconds. Each diagram has three curves, representing the highest value (green), average value (yellow) and lowest value (blue). This means the diagram displays rapid changes accurately. It is also a good indication of the signal stability. A significant difference between highest and lowest values indicates an unstable reference point, such as tree branches.

4. To the right, the screen shows the sensor’s current distance, highest and lowest distance measured in the last 60 second and the current weather intensity.

11

Web interface - Device configuration

5.3.2. Device configuration

1. Open the ‘Device configuration’ tab. 2. The sensor’s current network and user settings are shown.

3. To change TCP/IP settings, press ‘edit settings’ under the network settings. Input fields will appear to the right. 4. Modify the settings as needed and press the save button when done. If you change the sensor’s IP address, you will have to reload the page with the new IP address.

5. To change current login settings, press ‘edit settings’ under the login section. Input fields will appear to the right.

6. Enter a new username and password. 7. Press the save button to confirm. 12

Web Interface - Import & export settings

5.3.3. Import and export settings

Alarm settings can be exported as a file for backup and to copy settings to other sensors. IP address and login settings are not included in the exported file.

1. Open the Import and export settings tab.

2. Export all current alarm settings by pressing the ‘Download’ button. Pay attention to the file location on your hard drive. The file name is individual for each sensor as it includes the sensor’s MAC address. 3. To import a setting file, press ‘Choose File’ and navigate to the location of the previously saved setting file on your hard drive.

4. When the file is selected, press the ‘Upload’ button. Pay attention to the status message next to the button. Importing a setting file will overwrite all current settings.

13

Web interface - Firmware update

5.3.4. Firmware update

The SiteWatch™ laser sensor’s firmware should be updated when new versions are available. To update the sensor’s firmware: 1. Open the Firmware update tab. The sensor’s current firmware version is displayed. 2. Press the ‘Update firmware’ button to enter the system bootloader.

3. In the bootloader, you have the option to upload a new firmware, clear all settings (restore factory settings) and restore to the factory firmware.

4. Press ‘Start firmware’ to start the laser sensor’s current firmware again. 5. Press ‘Clear settings’ to restore the unit to its factory settings. 6. Press ‘Restore factory firmware’ to restore the unit’s factory firmware.

7. To upload a new firmware, press ‘Choose File’ and navigate to the location of the firmware file on your hard drive. When a file is selected, the file name will be displayed next to the button.

NOTE:

Uploading a new firmware will erase all alarm and configuration settings.

8. Press ‘Upload’. When the firmware file is uploaded, the unit will reboot the system with the new firmware. 9. After a reboot the firmware settings page will be shown again. 10. Press Start firmware button to restart the Night Watch™ laser with the new firmware.

14

Web interface - Alarm settings

5.4. ALARM SETTINGS

The SiteWatch™ laser has four types of alarms, zone alarms, reference point alarms, time/heartbeat alarms and weather alarms. All alarms are designed for network communication, but the built-in relay can also be used.

5.4.1. Zone alarms

Zone alarms are standard alarms for object detection. Up to 20 zones can be created and each zone can have individual settings and alarm actions. 1. Open the Alarm settings tab.

2. Press ‘+ Add zone’ to create a new alarm zone. Input fields will appear on the right.

3. Enter a zone name.

4. Under ‘near distance’, enter the distance at which the zone should start.

5. Under ‘far distance’, enter the distance at which the zone should end. 6. Click ‘Add alarm’ to save the settings. The laser sensor also offers advanced alarm settings. These settings can be used to adapt the zones for special pur poses. We recommend to thoroughly verify the function of the alarm zone if these settings are changed. 7. Press ‘Advanced settings’ to show the additional settings options. 8. Sensitivity: use the sensitivity bar to adjust the detection sensitivity. High sensitivity levels can be used for appli cations where highest detection is necessary. This may also increase the probability of false alarms. Low sensitivi ty can be used where the objects are big and slow (for example: detection of boats). 9. Delay: allow a zone alarm to react if an object has stopped in the zone. Enter the time for which an object must stay in the zone before the alarm is activated. Default value is 0 seconds, maximum is 120 second (2 minutes).

10. Timeout: the time before a zone alarm resets once an object has been detected. This can be used to avoid extra alarms from objects that may create multiple detections (for example: masts on a boat). Default value is 0 sec onds, maximum is 120 seconds (2 minutes).

11. Speed limit: enter a speed limit which an object must travel before the alarm is activated. Enter in meters per second. Repeat the steps above for each new zone. To edit a zone, press the zone name. To remove a zone, press ‘Remove’ next to the zone name. The zone and all actions for the zone will be removed. 15

Web interface - Alarm zones actions

5.4.2. Alarm zones actions

1. Press ‘+ Add action’ under the desired alarm zone. Input fields appear on the right.

2. Choose the action event type from the options in the drop-down menu. ‘Relay action’ and ‘Connect to URL’ are available. For relay action, go to step 5. 3. If ‘Connect to URL’ is selected, enter the IP address to connect to, such as the VMS server.

4. Depending on the VMS, alarm disable URL may be needed. 5. Press the ‘Save’ button to confirm settings.

6. Repeat for each zone as needed.

7. To edit an action, press ‘Edit’ next to the action in the list.

8. To remove an action, press ‘Remove’ next to the action in the list. 16

Web interface - Reference point

5.4.3. Reference point

Reference point alarm is a tampering alarm used to detect if the sensor has been moved or covered. Reference point alarm is possible only when the laser sensor is aligned in a manner where there is a reference object and the signal stability is good. To add a reference point alarm: 1. In the Alarm settings tab, click on ‘Add alarm’. 2. Select ‘Reference point’ from the ‘Input’ drop-down menu. 3. Enter the distance to a selected reference point in meters. 4. Enter the target variance, the maximum allowed change in distance relative to the reference point before the alarm is triggered. Enter values in meters.

5. If applicable, enter a value for alarm delay. This indicates the time which the reference point must be faulty before an alarm is activated. To avoid false alarms, the alarm delay should be significantly different from the time of a standard object passage. 6. Press ‘Add’ to confirm the settings.

7. To create alarm actions for the reference point, press ‘+ Add action’. Input fields appear on the right. 8. Choose the action event type from the drop-down menu options. 9. Press ‘Save’ to confirm settings.

17

Web interface - Timer / Heartbeat

5.4.4. Timer / Heartbeat

The timer / heartbeat is a tampering alarm used to detect a cable break or product malfunction by periodically send ing a short message to the server.

To setup a timer / heartbeat alarm: 1. In the Alarm settings tab, click on ‘Add alarm’. 2. Select ‘Timer/heartbeat’ from the ‘Input’ drop-down menu. 3. Enter an alarm name for the new alarm. 4. Enter the time interval in seconds. This will indicate how often the system will send a short message to the server. 5. Click ‘Add alarm’ to save the new alarm settings. To add an action for a timer/heartbeat alarm: 6. Click on ‘Add action’ under the alarm’s name. 7. Choose the action event type from the drop-down menu options. 8. Press ‘Save’ to confirm settings.

18

Web interface - Weather alarm

5.4.5. Weather alarm

The laser sensor is constantly evaluating the measurement signal to determine the weather intensity at a scale from 0 to 10. This allows users to create alarm actions based on weather intensity. 1. In the Alarm settings tab, click on ‘Add alarm’. 2. Select ‘Weather alarm’ from the ‘Input’ drop-down menu. 3. Enter desired threshold level on weather intensity alarm (default is 1).

4. Enter a timeout value, the shortest time the weather alarm is active. Each time the weather intensity exceeds the threshold, the timeout is reset. Default time is 10 minutes.

5. Press ‘Add’ to save the new alarm.

6. Create Alarm actions for the weather alarm by pressing “+ Add action”. 7. Choose action event type from the drop-down menu options.

Connect to URL

If the weather intensity threshold is exceeded, the unit alarms to the URL.

- Enter desired URL, for example the VMS server.

- Depending on VMS, alarm disable URL can be needed.

Relay action

Activates the internal relay.

Disable reference point

If the weather intensity threshold is exceeded, reference point alarms are ignored.

8. Press the Add action button to confirm settings.

5.5. LOGOUT

1. Press the ‘Logout’ button on the top right of the menu bar. 2. You will automatically be logged out of the sensor’s web user. The system will log off from all users connected from any computer. 19

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

Can the Digital Watchdog DW-DTLA500 sensor detect reflections from multiple targets simultaneously?
Yes, the DW-DTLA500 sensor can analyze various reflections simultaneously thanks to its advanced algorithm.
What is the recommended detection range for demanding applications with the DW-DTLA500 sensor?
For optimal performance in challenging environments, it is recommended to use the sensor within a range of 984ft (300m).
How many alarm zones can be configured on the DW-DTLA500 sensor?
The DW-DTLA500 sensor supports up to 20 fully adaptable alarm zones, each with customizable sensitivity and actions.
How should the sensor be placed for perimeter detection?
For perimeter detection, position the sensor at the desired detection height and align it parallel to the ground.
What types of alarm actions can be configured for the DW-DTLA500 sensor?
The sensor allows you to configure various alarm actions, including network alarms, relay triggers, and easy integration with IP to VMS for PTZ control, automatic video recording, and object position monitoring.