MX-65xx series ASCII protocol
User guide V2.0
In this document
Introduction .................................................................................................................................................................. 1
RS232 protocol...................................................................................................................................................... 1
Telnet login ............................................................................................................................................................ 1
About ASCII commands (terminal commands) ................................................................................................ 1
Commands .................................................................................................................................................................... 1
Query firmware version - %VR ............................................................................................................................ 1
Route a single output - %PI ................................................................................................................................. 1
Increase the source number of a single output - %P+ .................................................................................... 2
Decrease the source number of a single output - %P-.................................................................................... 2
Map outputs - %MAP ........................................................................................................................................... 2
Read the EDID from an output - %EDRP ........................................................................................................... 2
Read the EDID from a source - %EDRI ............................................................................................................... 3
Copy the EDID of a display to a source - %EDLP .............................................................................................. 3
Copy an EDID from the default table to a source - %EDLD ............................................................................ 3
Factory reset - %FSET ........................................................................................................................................... 3
Power on - %PON ................................................................................................................................................. 4
Power off - %POFF ................................................................................................................................................ 4
Contact us ...................................................................................................................................................................... 4
Copyright © tvONE 2019
Jan-2019
Introduction
You can use these commands with RS-232 and Telnet.
Inputs connect to sources. Outputs connect to displays.
RS232 protocol
▪
▪
▪
▪
Baud Rate 9600 bps
Data bit: 8 bits
Parity: None
Stop Bit: 1 bit
Telnet login
▪
▪
User name: admin
Password: 123
About ASCII commands (terminal commands)
All commands must include Carrier Return/<CR> (0x0d)
Commands
Query firmware version - %VR
Description
Query the current version of the firmware.
Command
%VR
Arguments
None
Example
Command: %VR
Response: 8x8H_FW_01_02
This response means the device's current firmware is for an 8x8 matrix version 1.02
Route a single output - %PI
Description
This command is for routing to a single output.
Command
%PoxIix
Arguments
Where
Is
ox
The output port number. Must be two digits, 01, 02…
ix
The input port number. Must be two digits, 01, 02…
Example
To connect output 1 with input 3:
Command: %P01I03<CR>
Response: p01i03
To disconnect output 1 from all outputs (use a 0 for the input value
Command: %P01I00<CR>
Response: p01i00
MX-65xx series ASCII protocol user guide V2.0
1
Increase the source number of a single output - %P+
Description
This command is for changing a single output to the next input; similar to a channel up
command.
Command
%Pox+
Arguments
Example
Where
Is
ox
The output port number. Must be two digits, 01, 02…
To increase the source number for output 1, where the current source is input 2
Command: %P01+<CR>
Response: p01i03
Decrease the source number of a single output - %PDescription
This command is for changing a single output to the previous input; similar to a channel
down command.
Command
%Pox-
Arguments
Example
Where
Is
ox
The output port number. Must be two digits, 01, 02…
To decrease the source number for output 1, where the current source is input 3
Command: %P01-<CR>
Response: p01i02
Map outputs - %MAP
Description
This command shows output mapping, also known as a routing table.
Command
%MAP
none
p01i03
p02i01
p03i02
p04i04
Arguments
Response
Read the EDID from an output - %EDRP
Description
This command reads the EDID from an HDMI output .
Command
%EDRPox
Arguments
Where
Is
ox
The output port number. Must be two digits, 01, 02…
Example
To read the EDID from output 1
Command: %EDRP01<CR>
Response:
00 FF FF FF FF FF FF 00
35 34 11 20 00 00 00 1B
2
tvONE
Read the EDID from a source - %EDRI
Description
This command reads the EDID from an HDMI input .
Command
%EDRIix
Arguments
Where
Is
ix
The input port number. Must be two digits, 01, 02…
Example
To read the EDID from input 1
Command: %EDRI01<CR>
Response:
00 FF FF FF FF FF FF 00
35 34 11 20 00 00 00 1B
Copy the EDID of a display to a source - %EDLP
Descriptio
n
Command
Arguments
Example
This command copies the EDID from an output to an input.
%EDLPoxix
Where
Is
ox
The output port number. Must be two digits, 01, 02…
ix
The input port number. Must be two digits, 01, 02…
To copy the EDID from output 1 to input 2
Command: %EDLP0102<CR>
Response: OK
Copy an EDID from the default table to a source - %EDLD
Description
This command copies an EDID from the default EDID table to an input.
Command
%EDLDdxix
Arguments
Example
Where
Is
dx
The default EDID number. Must be two digits, 01, 02…
ix
The input port number. Must be two digits, 01, 02…
To copy the EDID from default 3 to input 2
Command: EDLD0302<CR>
Response: OK
Factory reset - %FSET
Description
This command resets your device to factory settings.
Command
Arguments
%FSET
none
Response
none
MX-65xx series ASCII protocol user guide V2.0
3
Power on - %PON
Description
This command starts your device.
Command
Arguments
%PON
none
Response
none
Power off - %POFF
Description
This command shuts down your device.
Command
Arguments
%POFF
none
Response
none
Contact us
www.tvone.com
[email protected]
tvONE NCSA
North, Central and South America
tvONE EMEA
Europe, Middle East, Africa and Asia Pacific
621 B Wilmer Avenue
Cincinnati, Ohio 45226
USA
Continental Approach, Westwood Industrial Estate,
Margate, Kent, CT9 4JG, UK
Toll Free: +1-800-721-4044
US Main: +1-513-666-4210
US Tech: +1 513-666-4220
Tel +44-1843-873311
Fax +44-1843-873312
Sales: [email protected]
Support: [email protected]
Sales: [email protected]
Support: [email protected]
Copyright 2019 tvONE. All rights reserved.
Information in this document is subject to change without notice. The software described in this
document is furnished under a license agreement or nondisclosure agreement. The software may be
used or copied only in accordance with the terms of those agreements. No part of this publication may be
reproduced, stored in a retrieval system, or transmitted in any form or any means electronic or
mechanical, including photocopying and recording for any purpose other than the purchaser's personal
use without the written permission of tvONE.
4
tvONE