Fujitsu ASGA12BMWA-B Operation Manual


Add to my manuals
48 Pages

advertisement

Fujitsu ASGA12BMWA-B Operation Manual | Manualzz

AIR CONDITIONER

WALL MOUNTED TYPE

COOLING MODEL

Indoor Unit

ASGA12BMWA-B

Outdoor Unit

AOGA12BMWA-B

KEEP THIS MANUAL

FOR FUTURE REFERENCE

OWNER’S MANUAL

SPECIFICATIONS

MODEL

INDOOR UNIT

OUTDOOR UNIT

TYPE

POWER SOURCE

COOLING

CAPACITY

POWER INPUT

CURRENT

ENERGY EFFICIENCY RATIO

MAX. PRESSURE

SUCTION

DISCHARGE

MAX. CURRENT

REFRIGERANT (R32)

DIMENSIONS & WEIGHT (NET)

INDOOR UNIT

H E I G H T

W I D T H

D E P T H

W E I G H T

OUTDOOR UNIT

H E I G H T

W I D T H

D E P T H

N e t W e i g h t

TEMPERATURE AND HUMIDITY RANGE

OUTDOOR TEMPERATURE

C O O L I N G / D R Y

SET TEMPERATURE RANGE

[ k W ]

[ k W ]

[ A ]

[ k W / k W ]

[MPa]

[MPa]

[A]

[ k g ]

[ m m ]

[ m m ]

[ m m ]

[ k g ]

[ m m ]

[ m m ]

[ m m ]

[ k g ]

ASGA12BMWA-B

AOGA12BMWA-B

WALL MOUNTED (COOLING MODEL)

220 - 240V ~ 50Hz

3 .

6 0 0

1 .

0 1 0

4 .

5

3 .

5 6

2.5

4.3

7.5

0 .

6 4

5 4 0

8 4 8

3 2 0

3 0

2 8 9

8 4 5

2 0 9

1 1

[ ° C ]

[ ° C ]

1 8 t o 4 8

1 6 t o 3 0

* The protective function might work when using it outside the temperature range mentioned above.

Acoustic Noise Information: The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor unit.

According to IEC 704-1 and ISO 3744.

If the air conditioner is operated under higher temperature conditions than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperatures than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.

If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip onto the floor or other objects underneath.

Content

Operation Notices

The Refrigerant ....................................................................................................1

Precautions ..........................................................................................................

Parts Name .........................................................................................................

2

9

Screen Operation Guide

Buttons on remote controller ............................................................................ 11

Introduction for icons on display screen ........................................................... 11

Introduction for buttons on remote controller ..................................................... 12

Function introduction for combination buttons.................................................... 1

Operation guide ................................................................................................. 1

Replacement of batteries in remote controller ................................................... 1

Emergency operation .........................................................................................1

Maintenance

Clean and Maintenance ..................................................................................... 1

Malfunction

Malfunction analysis ..........................................................................................

Installation Notice

Installation dimension diagram .......................................................................... 2

Safety precautions for installing and relocating the unit..................................... 2

Tools for installation ........................................................................................... 2

Selection of installation location ......................................................................... 2

Requirements for electric connection ................................................................ 2

Installation

Installation of indoor unit .................................................................................... 2

Installation of outdoor unit ................................................................................. 3

Vacuum pumping ............................................................................................... 3

Leakage detection ............................................................................................. 3

Check after installation ...................................................................................... 3

Test and operation

Test operation ................................................................................................... 3

Attachment

Configuration of connection pipe ....................................................................... 3

Safety operation of flammable refrigerant .........................................................

Pipe expanding method ..................................................................................... 4

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

If it needs to install, move or maintain the air conditioner, please contact dealer or local service center to conduct it at first. Air conditioner must be installed, moved or maintained by appointed unit. Otherw- ise, it may cause serious damage or personal injury or death.

Explanation of Symbols

DANGER

WARNING

CAUTION

NOTICE

Indicates a hazardous situation that, if not avoided, will result in death or serious injury.

Indicates a hazardous situation that, if not avoided, could result in death or serious injury.

Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.

Indicates important but not hazard-related information, used to indicate risk of property damage.

Indicates a hazard that would be assigned a signal word

WARNING or CAUTION.

Appliance filled with flammable gas R32.

Before use the appliance, read the owner’s manual first.

Before install the appliance, read the installation manual first.

Before repair the appliance, read the service manual first.

The Refrigerant

To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The used refrigerant is the fluoride R32, which is specially cleaned.

The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion under certain conditions. But the flammability of the refrigerant is very low. It can be ignited only by fire.

Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm to the ozonosphere. The influence upon the greenhouse effect is also lower. R32 has got very good thermodynamic features which lead to a really high energy efficiency. The units therefore need a less filling.

WARNING :

Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture. Should repair be necessary, contact your nearest authorized Service Centre. Any repairs carried out by unqualified personnel may be dangerous. The appliance shall be stored in a room without continuously operating ignition sources. (for example: open flames, an operating gas appliance or an operating electric heater.) Do not pierce or burn.

Appliance shall be installed, operated and stored in a room with a floor area larger than X m .

(Please refer to table "a" in section of " Safety Operation of Inflammable

Refrigerant" for Space X.)

Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s instructions only. Be aware that refrigrants not contain odour. Read specialist’s manual.

1

Precautions

WARNING

Operation and Maintenance

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance.

Cleaning and user maintenance shall not be made by children without supervision.

Do not connect air conditioner to multi-purpose socket.

Otherwise, it may cause fire hazard.

Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

.

Do not wash the air conditioner with water to avoid electric shock.

Do not spray water on indoor unit. It may cause electric shock or malfunction.

After removing the filter, do not touch fins to avoid injury.

Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.

2

Precautions

WARNING

Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.

Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner.

Do not extend fingers or objects into air inlet or air outlet. It may cause personal injury or damage.

Do not block air outlet or air inlet. It may cause malfunction.

Do not spill water on the remote controller, otherwise the remote controller may be broken.

When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals for service.

Power cord is overheating or damaged.

There’s abnormal sound during operation.

Circuit break trips off frequently.

Air conditioner gives off burning smell.

Indoor unit is leaking.

If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.

When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.

Do not step on top panel of outdoor unit, or put heavy objects. It may cause damage or personal injury.

3

Precautions

WARNING

Attachment

Installation must be performed by qualified professionals.

Otherwise, it may cause personal injury or damage.

Must follow the electric safety regulations when installing the unit.

According to the local safety regulations, use qualified power supply circuit and circuit break.

Do install the circuit break. If not, it may cause malfunction.

An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring.

Including an circuit break with suitable capacity, please note the following table.

Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload.

Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock.

Don't use unqualified power cord.

Make sure the power supply matches with the requirement of air conditioner.

Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.

Properly connect the live wire, neutral wire and grounding wire of power socket.

Be sure to cut off the power supply before proceeding any work related to electricity and safety.

4

Precautions

WARNING

Do not put through the power before finishing installation.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.

The appliance shall be installed in accordance with national wiring regulations.

Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only

The air conditioner is the first class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.

The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.

The grounding resistance should comply with national electric safety regulations.

The appliance must be positioned so that the plug is accessible.

All wires of indoor unit and outdoor unit should be connected by a professional.

If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.

5

Precautions

WARNING

For the air conditioner with plug, the plug should be reachable after finishing installation.

For the air conditioner without plug, an circuit break must be installed in the line.

If you need to relocate the air conditioner to another place, only the qualified person can perform the work.

Otherwise, it may cause personal injury or damage.

Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.

The indoor unit should be installed close to the wall

Please notice that the unit is filled with flammable gas

R32. Inappropriate treatment of the unit involves the risk of severe damages of people and material. Details to this refrigerant are found in chapter “refrigerant”.

Check whether the maintenance area or the room area meet the requirement of the nameplate.

- It’s only allowed to be operated in the rooms that meet the requirement of the nameplate.

Check whether the maintenance area is well-ventilated.

- The continuous ventilation status should be kept during the operation process.

Check whether there is fire source or potential fire source in the maintenance area.

- The naked flame is prohibited in the maintenance area; and the “no smoking” warning board should be hanged.

- Replace the vague or damaged warning mark.

unload and open the container.

No fire source and smoking.

According to the local rules and laws.

6

Precautions

WARNING

The air conditioner is not allowed to use in a room that has running fire (such as fire source, working coal gas ware, operating heater).

It is not allowed to drill hole or burn the connection pipe.

The air conditioner must be installed in a room that is larger than the minimum room area. The minimum room area is shown on the nameplate or following table a.

Leak test is a must after installation.

Instructions for installation and use of this product are provided by the manufacturer.

7

[Information on disposal for users]

This symbol means that waste of electrical and electronic products (e-waste) shall not be dumped into dustbin for general waste. Please dispose of this product appropriately by handing over to authorized collection center or registered dismantler or recycler for e-waste. Do not try to dismantle the system yourself as this could have harmful effects on your health and on the environment.

[Information on hazardous constituents]

This product does not contain 6 hazardous substances in accordance with Article 13(1) in The e-waste (Management and

Handling) Rules, 2011.

8

Parts Name

Indoor Unit air inlet panel aux.button

horizontal louver air outlet

(Display content or position may be different from above graphics, please refer to actual products) remote control

Outdoor Unit air inlet

Connection wire air outlet

NOTICE:

Actual product may be different from above graphics, please refer to actual products.

9

Parts

N

ame

Display display temp.

indicator receiver window

Power LED color indicator:

Green-status-ON.

Red -status-OFF.

Mode LED color indicator:

White-Cool Mode-

Red-Heat Mode(only for heating model)

Orange-Dry Mode-

Display content or position may be different from above graphics, please refer to actual products.

10

Buttons on remote controller

1

3

6

8

10

11

2

4

5

7

9

12

10

11

12

1

2

7

8

9

On/Off button

Mode button

5

6

3 Fan button

4

Swing button

Sleep button

Temp button

Powerful button

Sensor button

Timer button

Auto Clean button

Light button

Introduction for icons on display screen

:Set temp.

Temp. display type

:Indoor ambient temp.

:Outdoor ambient temp.

Powerful mode

Set fan speed

Operation mode

Auto mode

Cool mode

Dry mode

Fan mode

Heat mode

Send signal

Child lock ventilation operation

8 ℃ heating function

Set temperature

Light function

Sensor function

Sleep mode

Set time

Auto clean mode

TIMER ON /TIMER OFF

do not. Please refer to the actual models.

Up & down swing

NOTICE: “ ” This is a general remote controller. Some models have this function while some

11

Introduction for buttons on remote controller

Note:

● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.

● After putting through the power, the air conditioner will give out a sound.

Operation indicator " " is ON (red indicator,the colour is different for different models). After that, you can operate the air conditioner by using remote controller.

● Under on status, pressing the button on the remote controller, the signal icon " " on the display of remote controller will blink once and the air conditioner will give out a “de” sound, which means the signal has been sent to the air conditioner.

● Under off status, set temperature and clock icon will be displayed on the display of remote controller (If timer on, timer off and light functions are set, the corre-

sponding icons will be displayed on the display of remote controller at the same

time); Under on status, the display will show the corresponding set function icons.

1

On/Off button

Press this button to turn on the unit. Press this button again to turn off the unit.

2

Mode button

Each time you press this button,a mode is selected in a sequence that goes from

AUTO, COOL, DRY, FAN, and HEAT *, as the following:

AUTO COOL DRY FAN HEAT

*

* Note: Only for models with heating function.

3

Fan button

This button is used for setting Fan Speed in the sequence that goes from AUTO,

, to , then back to Auto.

* Note: Fan speed under dry mode is low speed.

4

▲ / button

▲ eset temperature. In AUTO mode, set temperature is not adjustable.

When setting Timer On or Timer Off, pres

5

Swing button

Press this button to set up & down swing angle.

6

Sleep button

Under Cool, Heat or Dry mode, press this button to turn on Sleep function.

Press this button again to cancel Sleep function. Under Fan and Auto modes, this function is unavailable.

12

Introduction for buttons on remote controller

7

Temp button

Press this button, you can see indoor set temperature, indoor ambient temperature on indoor unit’s display. The setting on remote controller is selected circularly as below: no display

Note:

● Outdoor temperature display is not available for some models. At that time, indoor unit receives " " signal, while it displays indoor set temperature.

8

Powerful button

Under COOL or HEAT mode, press this button to activate / deactivate the Powerful function.

9

Sensor button

Press this button to start Sensor function and " " will be displayed on the remote controller. After this function is set, the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the detected temperature. Press this button again to close Sensor function and " " will disappear. When Sensor function is turned on, the remote controller should be put within the area where indoor unit can receive the signal sent by the remote controller.

10

Timer button

● Under ON status, press this button to set timer OFF; Under OFF status, press

this button to set timer ON.

● Press this button once and the characters of HOUR ON (OFF) will flash to be displayed. Meanwhile, press " " button or " " button to adjust timer setting (time ▲ will change quickly if holding " " or " " button). Time setting range is 0.5~24hours.

Press this button again to confirm timer setting and the characters of HOUR ON

(OFF)will stop flashing.

If the characters are flashing but you haven’t press timer button,timer setting status will be quit after 5s.If timer is confirmer, press this button again to cancel timer.

11

Auto Clean button

Press this button in COOL or DRY mode to turn on Auto clean function.

When this function is started up, indoor fan will still operate at low fan speed for a while after turning off the unit by remote controller.

12 Light button

Press this button to turn on the display's light and press this button again to turn off the display's light.

13

Function introduction for combination buttons

Combination of " " and " " buttons: About lock

▲ controller is locked, is displayed. In this case, pressing any button, blinks three times.

Combination of "MODE" and " " buttons:

About switch between Fahrenheit and centigrade

At unit OFF, press "MODE" and " " buttons simultaneously to switch between ℃ and ℉ .

Combination of "TEMP" and "TIMER" buttons:

About Energy-saving Function

Press "TEMP" and "TIMER" simultaneously in COOL mode to start e nergy-saving function.

Nixie tube on the remote controller displays "SE". Repeat the operation to quit the function.

Combination of "TEMP" and "TIMER" buttons:

About 8 ℃ Heating Function

Press "TEMP" and "TIMER" simultaneously in HEAT mode to start 8 ℃ Heating Function

Nixie tube on the remote controller displays " " and a selected temperature of "8 ℃ ".

(46 ℉ if Fahrenheit is adopted). Repeat the operation to quit the function.

WIFI Function

Press "MODE" and "POWERFUL" button simultaneously to turn on or turn off WIFI function. When WIFI function is turned on, the " " icon will be displayed on remote controller; Long press "MODE" and "POWERFUL" buttons simultaneously for

10s, remote controller will send WIFI reset code and then the WIFI function will be turned on. WIFI function is defaulted ON after energization of the remote controller.

● This function is only available for some models.

1 4

Operation guide

1.

After putting through the power, press "ON/OFF" button on remote controller to

turn on the air conditioner.

2.

Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN,

HEAT.

3.

Press "▲" or " " button to set your required temperature. (T emperature can’t

be adjusted under auto mode).

4.

Press "FAN" button to set your required fan speed: auto, low, medium and high

speed.

5.

Press "SWING" button to select fan blowing angle.

Replacement of batteries in remote controller

signal sender battery 1. Press the back side of remote controller marked

the cover of battery box along the arrow direction.

2. Replace two 7# (AA A 1.5V) dry batteries, and

make sure the position of "+" polar and "-" polar

are correct.

3. Reinstall the cover of battery box.

reinstall remove

Cover of battery box

NOTICE

● During operation, point the remote co ntrol signal sender at the receiving

window on indoor unit.

● The distance between signal sender and receiving window should be no

more than 8m, and there should be no obstacles between them.

or wireless telephone; remote controller should be close to indoor unit during

operation.

● Replace new batteries of the same model when replacement is required.

● When you don’t use remote controller for a long time, please take out the

batteries.

● If the display on remote controller is fuzzy or there ’s no display, please

replace batteries.

1 5

Emergency operation

If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode.

panel aux. button

WARNING:

Use insulated object to press the auto button

Clean and maintenance

WARNING

■ Turn off the air conditioner and disconnect the power before cleaning the air

conditioner to avoid electric shock.

■ Do not wash the air conditioner with water to avoid electric shock.

■ Do not use volatile liquid to clean the air conditione r.

Clean surface of indoor unit

When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or wet cloth to wipe it.

NOTICE:

● Do not remove the panel when cleaning it.

1 6

Clean and maintenance

1

Open panel

Pull out the panel to a certain 3 ● Use dust catcher or water to

the water (below 45 ℃ ) to clean

it, and then put it in a shady

and cool place to dry .

2

4 panel cover tightl y .

WARNING

operation environment, clean frequency can be increased.

1 7

Clean and maintenance

NOTICE: Checking before use-season

1. Check whether air inlets and air outlets are blocked.

2. Check whether air switch, plug and socket are in good condition.

4. Check whether mounting bracket for outdoor unit is damaged or corroded.

If yes, please contact dealer.

5. Check whether drainage pipe is damaged.

NOTICE: Checking after use-season

1. Disconnect power supply.

3. Check whether mounting bracket for outdoor unit is damaged or corroded.

If yes, please contact dealer.

Notice for recovery

1. Many packing materials are recyclable materials.

Please dispose them in appropriate recycling unit.

2. If you want to dispose the air conditioner, please contact local dealer or

consultant service center for the correct disposal method.

18

Malfunction analysis

General phenomenon analysis

Please check below items before asking for maintenance. If the malfunction still

Phenomenon Check items Solution

Indoor unit can’t receive remote controller’s signal or remote controller has no action.

● Whether it's interfered severely

(such as static electricit y , stable

voltage)?

● Whether remote controller is

within the signal receiving

range?

● Pull out the plug. Reinsert

the plug after about 3min, and

then turn on the unit again.

● Signal receiving range is 8m.

● Whether there are obstacles?

● Whether remote controller is

pointing at the receiving

window?

● Is sensitivity of remote contro-

ller low; fuzzy display and no

display?

● No display when opera

remote controller?

ting

● Fluorescent lamp in room?

● Remove obstacles.

● Select proper angle and point

the remote controller at the re-

ceiving window on indoor unit.

● Check the batteries. If the

power of batteries is too low,

please replace them.

● Check whether remote cont-

roller appears to be damaged.

If yes, replace it.

● Take the remote controller

close to indoor unit.

No air emitted from indoor unit

and then try it again.

● Air inlet or air outlet of indoor

unit is blocked?

● Under heating mode, indoor

temperature is reached to set

temperature?

● Heating mode is turned on just

now?

● Eliminate obstacles.

● After reaching to set temper-

ature, indoor unit will stop bl-

owing out air.

● In order to prevent blowing

out cold air, indoor unit will be

started after delaying for sev-

eral minutes, which is a nor-

mal phenomenon.

1 9

Malfunction analysis

Phenomenon

Air conditioner can’t operate

Check items

● Whether the function setting

for remote controller is

correct?

Solution

● Power failure?

● Is plug loose?

● Wait until power reco v ery.

● Reinsert the plug.

● Air switch trips off or fuse is

burnt out?

● Wiring has malfunction?

● Ask professional to replace

air switch or fuse.

● Ask professional to replace it.

● Unit has restarted immediately

after stopping operation?

● Wait for 3min, and then turn

on the unit again.

● Reset the function.

Mist is emitted from indoor unit’s air outlet

● Indoor temperature and hum-

idity is high?

● Because indoor air is cooled

rapidly. After a while, indoor

temperature and humidity will

be decrease and mist will

disappear.

Set temperature can’t be adjusted

Cooling

(heating) effect is not good.

● Unit is operating under auto

mode?

● Y our required temperature

exceeds the set temperature

range?

● T emperature can’t be adju-

sted under auto mode.

Please switch the operation

mode if you need to adjust

temperature.

● Set temperature range:

16 ℃ ~30 ℃ .

● V oltage is too low?

● Wait until the voltage

resumes normal.

● Filter is dirty?

● Set temperature is in proper

range?

● A djust temperature to proper

range.

● Door and window are open?

● Close door and window.

2 0

Malfunction analysis

Phenomenon Check items Solution

Odours are emitted

● Whether there ’s odour source,

such as furniture and cigarette,

etc.

● Eliminate the odour source.

Air conditioner operates abnormally suddenly

● Whether there ’ s interference,

such as thunder , wireless

devices, etc.

● Disconnect powe r , put back

power , and then turn on the

unit again.

Outdoor unit h vapor as ● Heating mode is turned on?

● During defrosting under he-

ating mode, it may generate

vapor , which is a normal

phenomenon.

“ W ater noise

● Air conditioner is turned on or

turned of f just now?

● The noise is the sound of

the unit, which is a normal

phenomenon.

Cracking noise

● Air conditioner is turned on or

turned of f just now?

● This is the sound of friction

caused by expansion and/or

contraction of panel or other

parts due to the change of

temperature.

2 1

Malfunction analysis

Error Code

● When air conditioner status is abnormal, temperature indicator on indoor unit will

ation of error code.

Error code

E5

T roubleshooting

It can be eliminated a ft er restarting the unit. If not, please

E8

It can be eliminated a ft er restarting the unit. If not, please

U8

It can be eliminated a ft er restarting the unit. If not, please

H6

It can be eliminated a ft er restarting the unit. If not, please

It can be eliminated a ft er restarting the unit. If not, please

H3

C5

F1

F2

F4

F0

E1

It can be eliminated after restarting the unit. If not, please service.

WARNING

■ When below phenomenon occurs, pl ease turn off air conditioner and discon-

for service.

● Power cord is overheating or damaged.

● There’ s abnormal sound during operation.

● Circuit break trips o ff frequently.

● Air conditioner gives o f f burning smell.

● Indoor unit is leaking.

■ If the air conditioner operates under a bnormal conditions, it may cause

2 2

Installation dimension diagram

Space to the wall

At least 15cm

At least 15cm

Space to the wall

At least 300cm

Space to the obstruction

At least 30cm

Space to the wall

At least 200cm

Space to the obstruction

2 3

Space to the obstruction

At least

30cm

At least 50cm

Space to the obstruction

Drainage pipe

Safety precautions for installing and relocating the unit

To ensure safety, please be mindful of the following precautions.

Warning

When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant.

Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury.

When installing or moving this unit, do not charge the refrigerant which is not comply with that on the nameplate or unqualified refrigerant.

Otherwise, it may cause abnormal operation, wrong action, mechanical malfunction or even series safety accident.

When refrigerant needs to be recovered during relocating or repairing the unit, be sure that the unit is running in cooling mode.Then, fully close the valve at high pressure side (liquid valve).About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power. Please note that the time for refrigerant recovery should not exceed 1 minute.

If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury.

During refrigerant recovery, make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe.

If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury.

When installing the unit, make sure that connection pipe is securely connected before the compressor starts running.

If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury.

Prohibit installing the unit at the place where there may be leaked corrosive gas or flammable gas.

If there leaked gas around the unit, it may cause explosion and other accidents.

Do not use extension cords for electrical connections. If the electric wire is not long enough, please contact a local service center authorized and ask for a proper electric wire.

Poor connections may lead to electric shock or fire.

Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the wires so that their terminals receive no external stresses.

Electric wires with insufficient capacity, wrong wire connections and insecure wire terminals may cause electric shock or fire.

2 4

Tools for installation

1 Level meter

4 Drill head

7 Open-end wrench

10 Vacuum pump

2 Screw driver

5 Pipe expander

8 Pipe cutter

11 Pressure meter

3 Impact drill

6 Torque wrench

9 Leakage detector

12 Universal meter

13 Inner hexagon spanner

Note:

14 Measuring tape

● Please contact the local agent for installation.

Selection of installation location

Basic requirement

Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local dealer:

1.The place with strong heat sources,

, or volatile objects spread in the air.

2.The place with high-frequency devices (such as welding machine, medical equipment).

3.The place near coast area.

4.The place with oil or fumes in the air.

5.The place with sulfureted gas.

6.Other places with special circums-

tances.

7.The appliance shall not be install-

ed in the laundry

Outdoor unit

Indoor unit

1. There should be no obstruction near air

inlet and air outlet.

2. Select a location where the condensat-

ion water can be dispersed easily and

won't affect other people.

3. Select a location which is convenient to

connect the outdoor unit and near the

power socket.

4. Select a location which is out of reach

for children.

5. The location should be able to withstand

the weight of indoor unit and won't incr-

ease noise and vibration.

6. The appliance must be installed 2.5m

7. Don't install the indoor unit right above the electric appliance.

8. Please try your best to keep way from fluorescent lamp.

will not affect neighborhood.

2. The location should be well ventilated and dry, in which the outdoor unit

won't be exposed directly to sunlight or strong wind.

3. The location should be able to withstand the weight of outdoor unit.

4. Make sure that the installation follows the requirement of installation dimension diagram.

5. Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.

2 5

Requirements for electric connection

Safety precaution

1. Must follow the electric safety regulations when installing the unit.

air switch.

3. Make sure the power supply matches with the requirement of air conditioner.

Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.

4. Properly connect the live wire, neutral wire and grounding wire of power socket.

5. Be sure to cut off the power supply before proceeding any work related to electricity and safety. For models with a power plug, make sure the plug is within reach after installation.

7. If the supply cord is damaged, it must be replaced by the manufacturer, its

8. The temperature of refrigerant circuit will be high, please keep the interconnec-

tion cable away from the copper tube.

9. The appliance shall be installed in accordance with national wiring regulations.

10. Appliance shall be installed, operated and stored in a room with a floor area

(Please refer to table "a" in section of " Safety Operation of

Inflammable Refrigerant" for Space X.)

Please notice that the unit is filled with flammable gas R32. Inappropriate treatment of the unit involves the risk of severe damages of people and material. Details to this refrigerant are found in chapter “refrigerant”.

Grounding requirement

grounding with specialized grounding device by a professional. Please make

sure it is always grounded effectively, otherwise it may cause electric shock.

2. The yellow-green wire in air conditioner is grounding wire, which can't be used

for other purposes.

3. The grounding resistance should comply with national electric safety regulations.

4. The appliance must be positioned so that the plug is accessible.

5. An all-pole disconnection switch having a contact separation of at least 3mm in

6. Including an air switch with suitable capacity, please note the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload. (Caution: please do not use the fuse only for protect the circuit)

Air-conditioner Air switch capacity

09K

12K

15/18/24K

10A

16A

25A

2 6

Installation of indoor unit

Step one: choosing installation location rm it with the client.

Step two: install wall-mounting frame

1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the

plastic expansion particles in the holes.

3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and

.

Step three: open piping hole

1. Choose the position of piping hole according to the direction of outlet pipe. The position of piping hole should be a little lower than the wall-mounted frame, shown as below.

12K: 9K:

Wall

Space to the wall above

150mm

Mark in the middle of it Level meter

Space to the wall above

150mm

Wall Wall

Space to the wall above

150mm

Mark in the middle of it Level meter

Wall

Space to the wall above

150mm

Left

Φ55mm

Rear piping hole

Right

Φ55mm

Rear piping hole

Left

Φ55mm

Rear piping hole

Right

Φ55mm

Rear piping hole

18K:

Wall

Space to the wall above

150mm

Mark in the middle of it

Left

Φ55mm

Rear piping hole

Level meter

Wall

Space to the wall above

150mm

Right

Φ55mm

Rear piping hole

24K:

Wall

Space to the wall above

150mm

Mark in the middle of it

Left

Φ55/70mm

Rear piping hole

Level meter

Wall

Space to the wall above

150mm

Right

Φ55/70mm

Rear piping hole

2.

Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet pipe position.In order to drain smoothl y , slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5-10°.

2 7

Installation of indoor unit

Note:

● Pay attention to dust prevention and

take relevant safety measures when

opening the hole.

● The plastic expansion particles are

not provided and should be bought

locally.

Indoor

5-10 outdoor

Φ55/

Φ70

Step four: outlet pipe

1. The pipe can be led out in the direction of right, rear right, left or rear left.

right left rear right rear left

2. When select leading out the pipe from left or right, please cut off the corresponding hole on the bottom case.

left right cut off the hole

1. Aim the pipe joint at the corresponding bellmouth.

2. Pretightening the union nut with hand.

pipe joint union nut pipe

3. Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union nut with torque wrench.

28

Installation of indoor unit

torque wrench open-end wrench union nut pipe indoor pipe

4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it with tape.

Hex nut diameter Tightening torque (N.m)

Φ 6 15~20

Φ 9.52

Φ 12

Φ 16

Φ 19

30~40

4 5 ~55

60~65

70~75 insulating pipe

Step six: install drain hose

1. Connect the drain hose to the outlet pipe of indoor unit.

drain hose outlet pipe

2. Bind the joint with tape.

tape

Note:

● Add insulating pipe in the indoor

drain hose in order to prevent

condensation.

● The plastic expansion particles are

not provided.

drain hose drain hose insulating pipe

Step seven: connect wire of indoor unit panel

1. Open the panel, remove the screw on the wiring cover and then take down the cover.

screw wiring cover

2 9

Installation of indoor unit

2. Make the power connection wire go

through the cable-cross hole at the back

of indoor unit and then pull it out from

the front side.

3. Remove the wire clip; connect the power

connection wire to the wiring terminal

according to the color; tighten the screw

with wire clip.

09 12 15 18K :

N(1) 2 cable-cross hole power connection wire

Outdoor unit connection

24K :

N(1) 2 blue black

3 brown yellowgreen

Outdoor unit connection

4. Put wiring cover back and then tighten the screw.

5. Close the panel.

Note:

● All wires of indoor unit and outdoor unit should be connected by a professional.

for a new one. Avoid extending the wire by yourself.

installation.

● For the air conditioner without plug, an circuit break must be installed in the line.

The air switch should be all-pole parting and the contact parting distance should

be more than 3mm.

3 0

Installation of indoor unit

Step eight: bind up pipe

1. Bind up the connection pipe, power

cord and drain hose with the band.

connection pipe indoor unit gas pipe indoor and outdoor power cord band liquid pipe drain hose

2. Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose.

drain hose band indoor power cord

3. Bind them evenly.

4. The liquid pipe and gas pipe should be bound separately at the end.

Note:

● The power cord and control wire

can't be crossed or winding.

● The drain hose should be bound

at the bottom.

Step nine: hang the indoor unit

1. Put the bound pipes in the wall pipe and then make them pass through the wall

hole.

2. Hang the indoor unit on the wall-mounting frame.

3. Stuff the gap between pipes and wall hole with sealing gum.

4. Fix the wall pipe.

5. Check if the indoor unit is installed firmly and closed to the wall.

indoor outdoor upper hook wall pipe sealing gum lower hook of wall-mounting frame

Note:

● Do not bend the drain hose too exce ssively in order to prevent blocking.

3 1

Installation of outdoor unit

(select it according to the actual installation situation)

1. Select installation location according to the house structure.

2. Fix the support of outdoor unit on the selected location with expansion screws.

Note:

installing the outdoor unit.

● Make sure the support can withstand at least

four times of the unit weight.

● The outdoor unit should be installed at least joint.

● For the unit with cooling capacity of 2300W

~5000W , 6 expansion screws are needed; for the unit with cooling capacity of 6000W

~8000W , 8 expansion screws are needed; for the unit with cooling capacity of 10000W

~16000W, 10 expansion screws are needed.

at least 3cm above the floor

(

Step two: install drain joint

O n l y

unit) f o r c o o il n g a n d h e a it n g

1. Connect the outdoor drain joint into

the hole on the chassis, as shown in

the picture below.

2. Connect the drain hose into the drain

vent.

1. Place the outdoor unit on the support.

2. Fix the foot holes of outdoor unit with bolts.

foot holes drain vent

Drain hose chassis outdoor drain joint

3 2 foot holes

Installation of outdoor unit

Step four: connect indoor and outdoor pipes

1. Remove the screw on the right han-

dle of outdoor unit and then remove

the handle.

3. Pretightening the union nut with

hand.

pipe joint screw handle

2. Remove the screw cap of valve and

aim the pipe joint at the bellmouth of

pipe.

liquid valve liquid pipe gas pipe gas valve union nut

4. Tighten the union nut with torque

wrench by referring to the sheet

below.

Φ 6

Φ 9.52

Φ 12

Φ 16

Φ 19

15~20

30~40

4 5~55

60~65

70~75

1. Remove the wire clip; connect the power connection wire and signal control

wire (only for cooling and heating unit) to the wiring terminal according to the

09 12 15K :

N(1) 2 blue black yellowgreen

18K :

N(1) 2 yellowgreen

Indoor unit connection Indoor unit connection

24K:

N(1) 2 blue black

3 brown yellowgreen

Indoor unit connection

3 3

Installation of outdoor unit

2. Fix the power connection wire and signal control wire with wire clip (only for

cooling and heating unit).

Note:

● Never cut the power connection wire to prolong or shorten the distance.

Step six: neaten the pipes

1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min.

semidiameter of bending the pipe is 10cm.

2. If the outdoor unit is higher than the wall hole, you must set a U-shaped curve in the pipe before pipe goes into the room, in order to prevent rain from getting into the room.

wall

U-shaped curve drain hose

Note:

● The through-wal height of drain hose

shouldn't be higher than the outlet

pipe hole of indoor unit.

the drain hose can't raise upwards.

● Slant the drain hose slightly dow-

nwards. The drain hose can't be

The drain hose can't be fluctuant

● The water outlet can't be placed in water in order to drain smoothly.

The drain hose can't be fluctuant

The water outlet can't be fluctuant

The water outlet can't be placed in water

3 4

Vacuum pumping

Use vacuum pump

1. Remove the valve caps on the liquid valve and gas valve and the nut of refri-

gerant charging vent.

2. Connect the charging hose

of piezometer to the refri-

gerant charging vent of gas

valve and then connect the

other charging hose to the

vacuum pump.

3. Open the piezometer com-

pletely and operate for

10-15min to check if the

pressure of piezometer re-

mains in -0.1MPa.

4. Close the vacuum pump liquid valve gas valve refrigerant charging vent nut of refrigerant charging vent inner hexagon spanner

and maintain this status for

1-2min to check if the pres-

sure of piezometer remains

in -0.1MPa. If the pressure decreases, there may be leakage.

piezometer valve cap close open

Lo vacuum pump

5. Remove the piezometer, open the valve core of liquid valve and gas valve

completely with inner hexagon spanner.

6. Tighten the screw caps of valves and refrigerant charging vent.

7. Reinstall the handle.

Hi

Leakage detection

1. With leakage detector:

Check if there is leakage with leakage detector.

2. With soap water:

If leakage detector is not available, please use soap water for leakage detection.

Apply soap water at the suspected position and keep the soap water for more than 3min. If there are air bubbles coming out of this position, there's a leakage.

3 5

Check after installation

Items to be checked Possible malfunction

The unit may drop, shake or emit noise.

Have you done the refrigerant leakage test?

Is water drained well?

(heating) capacity.

It may cause condensation and water dripping.

It may cause condensation and water dripping.

Is the voltage of power supply according to the voltage marked on the nameplate?

Is electric wiring and pipeline installed correctly?

It may cause malfunction or damaging the parts.

It may cause malfunction or damaging the parts.

Is the unit grounded securely?

It may cause electric leakage.

Does the power cord follow the speciIt may cause malfunction or damaging the parts.

Is there any obstruction in the air inlet and outlet?

The dust and sundries caused during installation are removed?

(heating) capacity.

It may cause malfunction or damaging the parts.

The gas valve and liquid valve of connection pipe are open completely?

(heating) capacit y.

Is the inlet and outlet of piping hole been covered?

It may cause insufficient cooling

(heating) capacity or waster eletricity.

Test operation

1. Preparation of test operation

● The client approves the air conditioner.

● Specify the important notes for air conditioner to the client.

2. Method of test operation

● Put through the powe r, press ON/OFF button on the remote controller to start operation.

● Press MODE button to select AUTO, COOL, DRY, F AN and HE AT to check whether the operation is normal or not.

● If the ambient temperature is lower than 16 ℃ , the air conditioner can’t start cooling.

3 6

Configuration of connection pipe

1. Standard length of connection pipe

● 5m 、 7.5m

、 8m

2. Min length of connection pipe

For the unit with standard connection pipe of 5m, there is no limitation for the min length of connection pipe. For the unit with standard connection pipe of

7.5m and 8m, the min length of connection pipe is 3m.

3. Max length of connection pipe

Sheet 1 Max length of connection pipe Unit: m capacity

Max length of connection pipe capacity

Max length of connection pipe

5000Btu/h

(1465W)

7000Btu/h

(2051W)

9000Btu/h

(2637W)

12000Btu/h

(3516W)

15

15

15

20

24000Btu/h

(7032W)

28000Btu/h

(8204W)

36000Btu/h

(10548W)

42000Btu/h

(12306W)

25

30

30

30

18000Btu/h

(5274W)

25

48000Btu/h

(14064W)

30

4. The calculation method of additional refrigerant oil and refrigerant charging amount after prolonging connection pipe

After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for each additional 5m of connection pipe.

The calculation method of additional re f rigerant charging amount (on the basis of liquid pipe):

(1) Additional refrigerant charging amount= prolonged length of liquid pipe × additional

(2) refrigerant charging amount per meter

Basing on the length of standard pipe, add refrigerant according to the requirement as shown in the table. The additional refrigerant charging amount

per meter is di f ferent according to the diameter of liquid pipe. See Sheet 2.

3 7

Configuration of connection pipe

Sheet 2. Additional refrigerant charging amount for R32

Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle

Liquid pipe Gas pipe

Cooling only, cooling and heating

(g / m)

Cooling only

(g / m) cooling and heating

(g / m)

Ф6 Ф9.5 or Ф12 16 12 16

Ф6 or Ф9.5

Ф12

Ф16 or Ф19

Ф19 or Ф22.2

40

80

12

24

40

96

Ф16 Ф25.4 or Ф31.8

_

136 48 96

Ф19 200 200 200

Ф22.2

_

280 280 280

Note: The additional refrigerant charging amount in Sheet 2 is recommended value, not compulsory.

38

Safety operation of flammable refrigerant

Qualification requirement for installation and maintenance man

All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised by the person who bears the qualification for using the flammable refrigerant.

It can only be repaired by the method suggested by the equipment’s manufacturer.

Installation notes

The air conditioner is not allowed to use in a room that has running fire (such as fire source, working coal gas ware, operating heater).

It is not allowed to drill hole or burn the connection pipe.

The air conditioner must be installed in a room that is larger than the minimum room area. The minimum room area is shown on the nameplate or following table a.

Leak test is a must after installation.

Minimum room area( m )

Charge amount (kg) ≤1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9

2 2.1

2.2

2.3

2.4

2.5

floor location window mounted wall mounted ceiling mounted /

/

/

/ 14.5 16.8 19.3

22 24.8 27.8 31 34.3 37.8 41.5 45.4 49.4 53.6

5.2 6.1

7 7.9 8.9 10 11.2 12.4 13.6 15 16.3 17.8 19.3

1.6 1.9 2.1

2.4

2.8 3.1 3.4 3.8

4.2

4.6

5 5.5

6

1.1 1.3 1.4 1.6 1.8 2.1 2.3 2.6 2.8 3.1 3.4 3.7

4

Maintenance notes

Check whether the maintenance area or the room area meet the requirement of the nameplate.

- It’s only allowed to be operated in the rooms that meet the requirement of the nameplate.

Check whether the maintenance area is well-ventilated.

- The continuous ventilation status should be kept during the operation process.

Check whether there is fire source or potential fire source in the maintenance area.

- The naked flame is prohibited in the maintenance area; and the “no smoking” warning board should be hanged.

Check whether the appliance mark is in good condition.

- Replace the vague or damaged warning mark.

Welding

If you should cut or weld the refrigerant system pipes in the process of maintaining, please follow the steps as below:

3 9

Safety operation of flammable refrigerant

a. Shut down the unit and cut power supply b. Eliminate the refrigerant c. Vacuuming d. Clean it with N2 gas e. Cutting or welding f. Carry back to the service spot for welding

The refrigerant should be recycled into the specialized storage tank.

Make sure that there isn’t any naked flame near the outlet of the vacuum pump and it’s well-ventilated.

Filling the refrigerant

Use the refrigerant filling appliances specialized for R32. Make sure that different kinds of refrigerant won’t contaminate with each other.

The refrigerant tank should be kept upright at the time of filling refrigerant.

Stick the label on the system after filling is finished (or haven’t finished).

Don’t overfilling.

After filling is finished, please do the leakage detection before test running; another time of leak detection should be done when it’s removed.

Safety instructions for transportation and storage

Please use the flammable gas detector to check before unload and open the container.

No fire source and smoking.

According to the local rules and laws.

4 0

Pipe expanding method

Note:

Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:

A: Cut the pipe E: Expand the port

● Expand the port with expande r.

the distance of indoor unit and

outdoor unit.

● Cut the required pipe with pipe cutte r.

pipe expander hard mold pipe pipe cutter leaning

B: Remove the burrs

● Remove the burrs with shaper and

prevent the burrs from getting into

the pipe.

pipe shaper downwards uneven burr

C: Put on suitable insulating pipe

D: Put on the union nut

● Remove the union nut on the indoor

connection pipe and outdoor valve;

install the union nut on the pipe.

union pipe

Note:

● "A" is di fferent according to the

diameter, please refer to the sheet

below:

Outer diameter

(mm)

Φ6 - 6.35(1/4")

Φ9.52(3/8")

Φ12-12.7(1/2")

Φ15.8-16(5/8")

Max

A(mm)

Min

1.3

1.6

0.7

1.0

1.8

2.4

1.0

2.2

F: Inspection

● Check the quality of expanding port.

If there is any blemish, expand the

port again according to the steps

above.