BEA 1SAFE User Guide
BEA 1SAFE is an active infrared safety sensor for automatic doors, designed to detect presence and prevent collisions. It features a 35mm x 70mm detection field, adjustable detection range from 0.6m to 3m, and a response time of 64ms. With a compact design and easy installation, it ensures increased door safety and can be used in various applications, including automatic doors, gates, and barriers.
Reklama
Reklama
User’s Guide for product version 0601 and higher
See product label for serial number
DESCRIPTION
1
2
1SAFE
Active infrared safety sensor for automatic doors*
7
3
4
9
8
5
6
1. LED
2. Emitter
3. DIP-switch
4. Push button
5. Setup adjustment screw
6. Fixation screw
7. Receiver
8. Cable with connector
9. Front face
TECHNICAL SPECIFICATIONS
Technology:
Detection mode:
Detection field:
Light indicator:
Response time:
Mounting height:
Supply voltage:
Mains frequency:
Max. current consumption:
Standard output:
Max. contact voltage:
Max. contact current:
Max. switching power:
Monitoring input:
Max. contact voltage:
Voltage threshold:
Hold time:
Reflectivity:
Temperature range:
Degree of protection:
Dimensions:
Housing material:
Length of main cable:
Norm conformity:
Test body: active infrared presence detection by distance measurement
35 mm x 70 mm (at 2.2 m mounting height) red LED: is ON during detection - orange LED flashes 1x after power on
64 ms
0.6 m - 3 m
12 V - 24 V AC/DC -5 % / + 10 %
50 - 60 Hz
120 mA @ 24 V AC / 80 mA @ 24 V DC relay (free of potential contact)
42 V AC/DC
1A (resistive)
30 W (DC) / 42 VA (AC)
1 optocoupler (free of potential contact)
30 V
High state: >10 V - Low state: <1 V
0.5 s min. 10 % at IR-wavelength of 850 nm
-25 °C - +55 °C; 0-95 % rel. humidity, non condensing
IP53
145 mm (L) x 40 mm (H) x 50 mm (D)
ABS (black)
2.5 m
EN 61000-6-2; EN 61000-6-3; EN 50581; EN ISO 13849-1 Performance Level «c» CAT. 2
(under the condition that the door control system monitors the sensor at least once per door cycle)
Test body CA in conformity with EN 16005
Specifications are subject to changes without prior notice.
Measured in specific conditions.
* Other use of the device outside of the permitted purpose can not be guaranteed by the manufacturer.
1
INSTALLATION
1 2 3
Use the mounting template to cut out the opening for the sensor.
4
After inserting the sensor, fix the 2 screws firmly.
6
Adapt the angle of the sensor.
5
Connect the cable and insert the sensor into the opening.
BROWN
GREEN
POWER SUPPLY
12-24 V AC/DC
YELLOW - COM
WHITE - NC
BLACK - NO
RED
BLUE
MONITORING
NO - ACTIVE
YELLOW-BLACK
NC - PASSIVE
YELLOW-WHITE
NO POWER
NO DETECTION
DETECTION
7 8
Unclips the front face by inserting a screwdriver as shown.
9
Push the push button shortly to launch an automatic setup.
The LED will flash RED-GREEN.
When the LED turns OFF the sensor is correctly installed.
Fasten the front face and test the good functioning of the sensor.
If the LED continues flashing, you have to adjust the sensor further (see SETUP next page).
The sensor can also be installed on the surface by using thesurface mount accessory (sold seperately).
2
1
ADDITIONAL ADJUSTMENTS (DIP-SWITCH)
OFF
(FACTORY VALUES)
AUTOMATIC MODE
ON
MANUAL MODE
Do not touch the screw.
It should be positioned as shown.
Push the push button shortly to launch an automatic setup.
When?
- low reflectivity of background
- no background or mounting height > 3 m
- mounting height < 1.6 m
- uncovered zone > 40 cm
How?
Decrease (-) or increase (+) the uncovered zone and check it by moving a white paper up and down under the sensor.
LED flashes RED-GREEN.
OK
2
3
Switch to manual mode.
SMALL (25 CM AT 2.2 M)
When?
When increased door safety is required.
Relaunch a setup after changing DIP 2.
4 Do not move the white paper horizontally!
BIG (40CM AT 2.2 M)
When?
When increased immunity to disturbances is required.
Relaunch a setup after changing DIP 2.
FREQUENCY 1
When?
When 2 or more sensors are installed in proximity to each other, it is recommended to choose different frequencies to avoid crosstalk.
FREQUENCY 2
When?
When 2 or more sensors are installed in proximity to each other, it is recommended to choose different frequencies to avoid crosstalk.
4
ACTIVE HIGH
When?
When the monitoring input mode is active high or when no monitoring is required.
ACTIVE LOW
When?
When the monitoring input mode is active low.
After changing a DIP-switch, the orange LED flashes. A LONG push on the push button confirms the settings.
INSTALLATION TIPS
Avoid reflective background or objects in the detection field of the sensor.
Avoid high intensity lightning in the detection field.
Do not cover the sensor.
Do not touch the optical parts.
TROUBLESHOOTING
The RED LED is
ON sporadicly or permanently.
The sensor does not react, but a calibration can be launched.
Bad calibration.
Bad adjustment of the uncovered zone.
The sensor is disturbed by lamps or another sensor.
The monitoring is activated, but the test input is not powered.
1
1
2
1
2
1
2
Launch a calibration.
Check if the DIP 2 is in correct position.
Launch a calibration.
Select a different frequency for each module (DIP 3).
Launch a calibration.
Check wiring.
- Door control with test:
Connect RED and BLUE wires to test output.
- Door control without test:
Connect BLUE to 0 V and RED to +12 V - 30 V DC.
Change position of DIP 4.
The ORANGE LED is on permanently.
The monitoring mode is wrong.
The sensor encounters a memory problem.
1 Send the sensor back for a technical check-up.
The ORANGE LED flashes quickly.
DIP-switch setting awaiting confirmation.
1 Confirm the DIP-switch setting: long push on the push button.
1
2
4
The ORANGE LED flashes 1 x every 3 seconds.
The ORANGE LED flashes 2 x every 3 seconds.
The ORANGE LED flashes 4 x every 3 seconds.
5
The ORANGE LED flashes 5 x every 3 seconds.
The sensor signals an internal fault.
Power supply is out of limit.
The sensor does not receive enough IR-energy.
Calibration error.
1
2
1
2
Cut and restore power supply.
If orange LED flashes again, replace sensor.
Check power supply (tension, capacity).
Reduce the cable length or change cable.
1
2
3
1
2
3
Launch a new calibration.
Step out of the detection field.
Change angle of spots.
Check mounting height.
Change position of calibration screw.
Launch a new calibration.
• The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer of the sensor.
• The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance
with applicable national and international regulations and standards on door safety.
• The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor.
• Only trained and qualified personnel may install and setup the sensor.
• The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel.
BEA SA | LIEGE Science Park | ALLÉE DES NOISETIERS 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | WWW.BEA-SENSORS.COM
BEA hereby declares that the 1SAFE is in conformity with the basic requirements and the other relevant provisions of the directives EMC 2014/30/EU and the RoHS 2 2011/65/EU.
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 13089615
The complete declaration of conformity is available on our website.