Water Quality Measurement Systems
Process Analytical Measurement Systems
2010
Ordering
Guide
pH
Optical DO
ORP
Free Chlorine
Turbidity
Contact Conductivity
Dissolved Oxygen
Toroidal Conductivity
Dissolved Ozone
Table of Contents:
Typical AdvantEDGE System .................................................................1
Interface Module..…………………………………… ................................2
Communication Adapter ……………………………………… ..................3
pH Sensor Head ………………………………………………… ...............4
pH accessories ……………………………………………………… ..........5
ORP Sensor Head ……………………………………………… ................6
ORP accessories ……………………………………………………… .......7
Free Chlorine Panel Measurement System ..........................................8
Turbidity System ………………………………………………… ...............9
Contacting Conductivity Sensor Head ……………………… ..................10
Toroidal Conductivity Sensor Head ………………………… ...................11
Dissolved Oxygen Sensor Head ……………………………… ................12
Optical Dissolved Oxygen Measurement…………………… ..................13
Dissolved Ozone Sensor Head .............................................................14
LD500 Local Display .............................................................................15
Profibus Gateway Adapter .....................................................................16
Mounting Hardware ……………………………………………… ..............17
Guide to Ordering Worksheet ................................................................18
AdvantEDGE System Components
As shown below, any AdvantEDGE sensor head plugs into the front end of the Interface Module. Any Comm unications Adapter plugs into the back end of the Interface Module to form a complete measurement system that can be mounted in process and be wired directly to a PLC, PDA or PC network. Measurement, calibration, configuration and diagnostics can be performed from a computer or from an intermediate LD500 Local Display.
A typical AdvantEDGE System consists of the three components listed below - Communications Adapter, Interface Module and Sensor Head.
See page 18 for a helpful guide to ordering worksheet.
Communications Adapter
A selection of plug and play communication modules provide power and direct interactive communications with control systems and computers. The table below shows the available protocols. If a local display is desired, the LD500 can be used. Multiple sensor assemblies can be used with the LD500.
Interface Module
The heart of the sensor assembly is the Universal Interface Module. It’s encapsulated measurement electronics automatically converts sensor signals into calibrated measurement units. It works with a variety of Communication Adapters to operate directly with any computer system.
Sensor Head
Pre-calibrated plug and play sensor heads can be replaced at any time, making AdvantEDGE the most versatile and accurate analytical measurement system on the market. The table below shows the parameters available.
Parameters
pH
ORP
Free Chlorine
Turbidity
Dissolved Oxygen
Optical Dissolved
Oxygen
Dissolved Ozone
Conductivity
Interface
Direct
Local Display
Communications
Protocols
Modbus RTU
Profibus
RS 485 ASCII
CANOpen
Device Net
Ethernet IP
USB
Control Room
SCADA
PLC
DCS
PC
Optional LD500
Local Display
Typical AdvantEDGE System Assembly
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
1
Rev 1.3 10-11-10
Communication Adapter
Interface Module
Sensor Head
AdvantEDGE Interface Module
Model Number
IM500 Interface Module integrates all sensor and communications functions. 1” NPT mounting standard. Sanitary and insertion mounting options available.
Body Material
1 316 Stainless Steel (Abrasion Resistant, Robust)
2 CPVC (Low Cost, All-Purpose)
3 PEEK (Food Grade, Chemically
Mounting Options
1 1-inch NPT threads, front and back (Standard)
CONTACT FACTORY FOR ADDITIONAL MOUNTING OPTIONS
IM Interface Module body part number
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
2
Rev 1.3 10-11-10
Communication Adapter
Interface Module
Sensor Head
AdvantEDGE Communications Adapter
Model Number
CA The AdvantEDGE Communications Adapter plugs into any Interface Module for direct connection to PLC, computer or PDA for full-featured measurement, calibration, configuration and diagnostics. It removes the need for an intermediate analyzer electronics box/local display. A Local Display can be used if desired.
Body Material
1 316 Stainless Steel (Abrasion Resistant, Robust)
2 CPVC (Low Cost, All-Purpose)
3 PEEK (Food Grade, Chemically
Communications
2B Modbus RTU, for LD500, PLC and Modbus networks. Required for Profibus networks.
1A RS-232 ASCII, for PC communication. AquaComm software included.
2A Modbus RS-232, for direct PC and PLC applications.
4B CANopen for PC and PLC networks.
5R DeviceNet for PLC networks.
7R Ethernet IP, Modbus TCP and TCP/IP for POE switches.
8R USB cables for PC and portable applications. AquaComm software included.
Cable Length
1 10 Feet
2 20 Feet
3 30 Feet
X Where X = Number of Feet/10
Reserved Category
CA A
Communications Adapter part number
General Guide for Communications Adapter Cable Length
Protocol
USB
RS-232 ASCII
DeviceNet
Max Drop Length
16.4 ft (5 meters)
50 ft (15 meters)
20 ft (6 meters)
Modbus RTU 50 ft (15 meters)
Modbus RS-232 50 ft (15 meters)
Notes
Supplied with Series ‘A’ Plug for direct connection to PC. Use with AquaComm™ software.
RS-232 power injector recommended (PN: JBOX232). Use with AquaComm™ software.
See Table 1 for details. Use Device Tap hardware for trunk connection.
See Table 2 for details. Use Device Tap hardware for trunk connection.
RS-232 power injector recommended (PN: JBOX232).
CANopen
Ethernet
72 ft (22 meters) See Table 3 for details. Use Device Tap hardware for trunk connection.
328 ft (100 meters) Use Ethernet Hub or Switch every 328 feet to extend cable distance.
Table 1: DeviceNet data rate versus drop length.
Data Rate Trunk Distance
125 kbps
250 kbps
500 kbps
1640 ft (500 meters)
820 ft (250 meters)
328 ft (100 meters)
Maximum
20 ft (6 meters)
Drop Length
Cumulative
512 ft (156 meters)
256 ft (78 meters)
128 ft (39 meters)
Table 2: Modbus RTU (RS-485) data rate versus drop length.
Data Rate
19.2 kbps
Trunk Distance
4000 ft (1219 meters)
Maximum
50 ft (15 meters)
Drop Length
Cumulative
250 ft (76 meters)
Table 3: CANOpen data rate versus drop length.
Data Rate Trunk Distance
125 kbps
250 kbps
500 kbps
1640 ft (500 meters)
820 ft (250 meters
328 ft (100 meters)
36 ft (11 meters)
18 ft (5.5 meters)
256 ft ( 78 meters)
128 ft (39 meters)
Note 1: For Profibus DP (V0/V1), connect up to 30 Modbus RTU Communications Adapter with a Profibus Gateway Adapter (Part Number: PA26R on page 16.
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
3
Rev 1.3 10-11-10
Communication Adapter Interface Module pH Sensor Head
AdvantEDGE pH Sensor Head
Model Number
PH Differential pH Sensor Head plugs in to any AdvantEDGE Interface Module and provides factory-calibrated measurement.
Integral ground rod, temperature measurement and replaceable salt bridge/reference solution.
Body Material
2 CPVC (Low Cost, All-Purpose)
3 PEEK (Food Grade, Chemically
Measurement Electrode
1 General Purpose Glass (Standard)
2 HF Glass (recommended for hydrofluoric acid (HF) applications)
3 Low Temperature Glass (recommended for temperatures below 5°C)
4 Pure Water Glass (recommended for conductivity below 10µS/cm)
5 High Temperature Glass (recommended for temperatures above 85°C)
Sensor Tip
A Protected Electrode (Standard)
B Process Flat (reduce protrusions)
C Face Seal for flow chamber installations (PEEK® material only)
Reserved Category
Ground Rod
1 316 Stainless Steel (for HF or customer specified applications)
2 Titanium (standard configuration)
PH 1A pH Sensor Head part number
AdvantEDGE System
Components
Description
316 Stainless Steel 1-inch sensor body
CPVC 1-inch sensor body
Communications Adapter CPVC Modbus RTU with 10 foot cable
Profibus Gateway Adapter Modbus RTU AdvantEDGE connects to Profibus DP
Local Display
LD500 Local Display
Description
One 4-20mA output, PID. 24VDC.
One 4-29mA output, PID, 100 – 240 VAC
Two 4-20mA outputs, PID, 2 Relays, Modbus Host, 24VDC.
Two 4-20mA outputs, PID, 2 Relays, Modbus Host, 100-240VAC
Part Number
IM11
IM21
CA22B1A
PA26R
Part Number
LDBB0A1
LDBB0A2
LDCB4C1
LDCB4C2
Typical pH Measurement Systems
(system without local display)
Communication Adapter Interface Module pH Sensor Head
CPVC Body
Modbus RS-232 30 ft of cable
CPVC Body
1-inch NPT
CPVC General Purpose Glass
Protected Tip Titanium Ground Rod
CA 2 2A 3 A IM 2 1 PH 2 1 A 1A 2
Reference
Page 1
Page 2
Page 16
Reference
Page 15
Optional
LD500 Local Display
One 4-20 output 24 VDC
Modbus RTU No Relays
LD B B 4 A 1
(system with local display)
Communication Adapter Interface Module
CPVC Body
Modbus RTU 10 ft of cable
CA 2 2B 1 A
CPVC Body
1-inch NPT
IM 2 1 pH Sensor Head
CPVC General Purpose Glass
Process Flat Tip Titanium Ground Rod
PH 2 1 B 1A 2
Note 1:
Note 2:
Table above shows selected Interface, Communications and LD500 components. See referenced pages for options.
Refer to data sheet for mounting hardware configuration details.
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
4
Rev 1.3 10-11-10
pH Calibration and Storage Solutions and other Accessories
Product
Solutions
4 pH buffer
7 pH buffer
10 pH buffer
Standard Cell Solution – 60ml
Standard Cell Solution – 500ml
Reference Cell Solution pH storage solution
Salt Bridges
PEEK, Protected Qty 1
PEEK, Protected Qty 3
PEEK, Protected Qty 10
PEEK, Process Flat Qty 1
PEEK, Process Flat Qty 3
PEEK, Process Flat Qty 10
PEEK, Face Seal Qty 1
PEEK, Face Seal Qty 3
PEEK, Face Seal Qty 10
CPVC, Protected Qty 1
CPVC, Protected Qty 3
CPVC, Protected Qty 10
CPVC, Process Flat Qty 1
CPVC, Process Flat Qty 3
CPVC, Process Flat Qty 10
Storage cover
Description
For Calibration – 500ml bottle
For Calibration – 500ml bottle
For Calibration – 500ml bottle
For sensor reference chamber – 60ml bottle
For sensor reference chamber – 500ml bottle
For sensor reference before serial number 2419 – 60ml bottle
Place in storage caps to keep glass electrode wet – 60ml bottle
For all pH and ORP sensors with PEEK bodies. Quantity 1
For all pH and ORP sensors with PEEK bodies. Quantity 3
For all pH and ORP sensors with PEEK bodies. Quantity 10
For all pH and ORP sensors with PEEK bodies. Quantity 1
For all pH and ORP sensors with PEEK bodies. Quantity 3
For all pH and ORP sensors with PEEK bodies. Quantity 10
For all pH and ORP sensors with PEEK bodies. Quantity 1
For all pH and ORP sensors with PEEK bodies. Quantity 3
For all pH and ORP sensors with PEEK bodies. Quantity 10
For all pH and ORP sensors with CPVC bodies. Quantity 1
For all pH and ORP sensors with CPVC bodies. Quantity 3
For all pH and ORP sensors with CPVC bodies. Quantity 10
For all pH and ORP sensors with CPVC bodies. Quantity 1
For all pH and ORP sensors with CPVC bodies. Quantity 3
For all pH and ORP sensors with CPVC bodies. Quantity 10
Comes with sponge to keep stored sensor electrodes wet
Note 1: Standard external salt bridge junctions constructed with Kynar. Ceramic available on request.
Note 2: Standard fill solutions can be gelled for high temperature applications on request.
Note 3: Refer to data sheet for mounting hardware configuration details.
Part Number
PHSOL4
PHSOL7
PHSOL10
RCS01
RCS01-500
RCS02
RCS03
SBS01-1
SBS01-3
SBS01-10
SBS02-1
SBS02-3
SBS02-10
SBS08-1
SBS08-3
SBS08-10
SBS03-1
SBS03-3
SBS03-10
SBS04-1
SBS04-3
SBS04-10
SBC01
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
5
Rev 1.3 10-11-10
Communication Adapter Interface Module ORP Sensor Head
AdvantEDGE Interface Differential ORP Sensor Head
Model Number
ORP Differential ORP Sensor Head plugs in to any AdvantEDGE Interface Module and provides factory-calibrated measurement.
Integral ground rod, temperature measurement and replaceable salt bridge/reference solution.
Body Material
2 CPVC (Low Cost, All-Purpose)
3 PEEK (Food Grade, Chemically
Measurement Electrode
1 Platinum (Standard applications)
2 Gold (Poisoning applications)
Sensor Tip
A Protected Electrode (Standard)
B Process Flat (reduce protrusions)
C Face Seal for flow chamber installations (PEEK® material only)
Reserved Category
Ground Rod
1 316 Stainless Steel (for HF or customer specified applications)
2 Titanium (standard configuration)
ORP 1A
ORP Sensor Head part number
AdvantEDGE System
Components
Description
316 Stainless Steel 1-inch sensor body
CPVC 1-inch sensor body
Communications Adapter CPVC Modbus RTU with 10 foot cable
Profibus Gateway Adapter Modbus RTU AdvantEDGE connects to Profibus DP
Local Display
LD500 Local Display
Description
One 4-20mA output, PID. 24VDC.
One 4-29mA output, PID, 100 – 240 VAC
Two 4-20mA outputs, PID, 2 Relays, Modbus Host, 24VDC.
Two 4-20mA outputs, PID, 2 Relays, Modbus Host, 100-240VAC
Part Number
IM11
IM21
CA22B1A
PA26R
Part Number
LDBB0A1
LDBB0A2
LDCB4C1
LDCB4C2
Reference
Page 1
Page 2
Page 16
Reference
Page 15
Typical ORP Measurement Systems
(system without local display)
Communication Adapter Interface Module ORP Sensor Head
CPVC Body
Modbus RS-232 30 ft of cable
CPVC Body
1-inch NPT
CPVC Platinum Electrode
Protected Tip Titanium Ground Rod
CA 2 2A 3 A IM 2 1 ORP 2 1 A 1A 2
Optional
LD500 Local Display
One 4-20 output 24 VDC
Modbus RTU No Relays
LD B B 4 A 1
(system with local display)
Communication Adapter Interface Module
CPVC Body
Modbus RTU 10 ft of cable
CA 2 2B 1 A
CPVC Body
1-inch NPT
IM 2 1
ORP Sensor Head
CPVC Platinum Electrode
Process Flat Tip 10 ft of cable
ORP 2 1 B 1A 2
Note 1:
Note 2:
Table above shows selected Interface, Communications and LD500 components. See referenced pages for options.
Refer to data sheet for mounting hardware configuration details.
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
6
Rev 1.3 10-11-10
ORP Calibration and Storage Solutions and other Accessories
Product
Solutions
200mV Solution
600mV Solution
Standard Cell Solution – 60ml
Standard Cell Solution – 500ml
Reference Cell Solution – 60ml
ORP storage solution
Salt Bridges
PEEK, Protected Qty 1
PEEK, Protected Qty 3
PEEK, Protected Qty 10
PEEK, Process Flat Qty 1
PEEK, Process Flat Qty 3
PEEK, Process Flat Qty 10
PEEK, Face Seal Qty 1
PEEK, Face Seal Qty 3
PEEK, Face Seal Qty 10
CPVC, Protected Qty 1
CPVC, Protected Qty 3
CPVC, Protected Qty 10
CPVC, Process Flat Qty 1
CPVC, Process Flat Qty 3
CPVC, Process Flat Qty 10
Storage cover
Description
ORP Calibration Solution – 500ml bottle
ORP Calibration Solution – 500ml bottle
For sensor reference chamber – 60ml bottle
For sensor reference chamber – 500ml bottle
For sensor reference before serial number 2419 – 60ml bottle
For storage caps to keep glass electrode wet – 60ml bottle
For all pH and ORP sensors with PEEK bodies. Quantity 1
For all pH and ORP sensors with PEEK bodies. Quantity 3
For all pH and ORP sensors with PEEK bodies. Quantity 10
For all pH and ORP sensors with PEEK bodies. Quantity 1
For all pH and ORP sensors with PEEK bodies. Quantity 3
For all pH and ORP sensors with PEEK bodies. Quantity 10
For all pH and ORP sensors with PEEK bodies. Quantity 1
For all pH and ORP sensors with PEEK bodies. Quantity 3
For all pH and ORP sensors with PEEK bodies. Quantity 10
For all pH and ORP sensors with CPVC bodies. Quantity 1
For all pH and ORP sensors with CPVC bodies. Quantity 3
For all pH and ORP sensors with CPVC bodies. Quantity 10
For all pH and ORP sensors with CPVC bodies. Quantity 1
For all pH and ORP sensors with CPVC bodies. Quantity 3
For all pH and ORP sensors with CPVC bodies. Quantity 10
Comes with sponge to keep stored sensor electrodes wet
Part Number
ORPSOL200
ORPSOL600
RCS01
RCS01-500
RCS02
RCS04
SBS01-1
SBS01-3
SBS01-10
SBS02-1
SBS02-3
SBS02-10
SBS08-1
SBS08-3
SBS08-10
SBS03-1
SBS03-3
SBS03-10
SBS04-1
SBS04-3
SBS04-10
SBC01
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
7
Rev 1.3 10-11-10
AdvantEDGE Free Chlorine Measurement Panel
Model Number
AEC500 Chlorine measurement system using the precalibrated chlorine sensor head, integral temperature with Interface module electronics, flow chamber, mounting plate and local display.
Display Configuration
1 Integral mount.
2 Remote mount with 20 foot cable.
LD500 Display Configuration
A User Interface with 1 current output. 24 VDC power.
B User Interface with 2 current outputs, 2 relays. 24 VDC power.
C User Interface with 2 current outputs, 2 relays. 100 VAC to 240 VAC power.
LD500 Host Communications Option
0 None
4 Modbus RTU (24 VDC and RS485 terminal connections in LD500)
5 DeviceNet (24 VDC and DeviceNet terminal connections in LD500)
6 CANopen (24 VDC and DeviceNet terminal connections in LD500)
7 Ethernet IP, Modbus/TCP, TCP/IP (PoE RJ45 Connector in LD500) pH Compensation
A Manual
B Automatic (with active pH sensor)
AEC
Free Chlorine Panel part number
Recommended AEC Panel Systems
Typical System
AEC Panel System. Integral LD500 with 1 output, flow chamber, Manual pH. 24VDC.
AEC Panel System. Integral LD500 with 2 outputs, 2relays, flow chamber, Automatic pH. 100/240VAC
Part Number
AEC1A0A
AEC1C0B
Chlorine Electrolyte and Accessories
Product
Chlorine Electrolyte
Membrane Assembly
Protective Cap
Description
Electrolyte in the PPM range. – 60ml bottle
Chlorine Membrane Cap with pre-stretched membrane
To keep membrane wet when stored.
Part Number
RDOK9
DMR09
SBC01
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
8
Rev 1.3 10-11-10
Interface
Module not needed
AdvantEDGE High Range Turbidity System
Communications Adapter Turbidity Sensor Head
Model Number
RT1 High Range Turbidity Measurement System. 0 to 4000 NTU Range. Polycarbonate sensor body. Temperature measurement included. Precalibrated.
Back-Body and Comms Adapter Material
1 CPVC 1-Inch NPT
2 316 Stainless Steel 1-Inch NPT
AdvantEDGE Communications Adapter
4 Modbus RTU. (Required for use with LD500 Local Display).
5 DeviceNet
6 CANopen
7 Ethernet IP, Modbus TCP, TCP/IP. Connect to PoE Switch with RJ45 connector.
8 USB 10 foot cable with A type connector for use with PC and portable computers.
Cable Length
1 10 Feet
2 20 Feet
3 30 Feet
X Where X = Number of Feet/10
RT1
High Range Turbidity Measurement System Part Number
AdvantEDGE System
Components
Profibus Gateway Adapter
Description
Modbus RTU AdvantEDGE connect to Profibus DP
Part Number Reference
PA26R Page16
Local Display Description
LD500 Local Display One 4-20mA output, PID. 24VDC.
One 4-20mA output, PID. 100 – 240 VAC
Two 4-20mA outputs, PID, 2 Relays, Modbus Host, 24VDC.
Two 4-20mA outputs, PID, 2 Relays, Modbus Host,100-240VAC
Turbidity Calibration Solutions
Product Description
Formazin Stock 4000 NTU Stock Solution – 500ml bottle
Formazin Kit
Wash Adapter
Wash Adapter
40 NTU Calibration Kit. Injector and 500ml mix bottle.
Air Purge Wash Adapter for DO Electrode, CPVC
Water Purge Wash Adapter for DO Elect., CPVC
Part Number Reference
LDBB0A1
LDBB0A2
LDCB4C1
LDCB4C2
Page 15
Part Number
FOR4K
FOR40
MH1142
MH1132
Typical Turbidity Systems
(system without local display)
Turbidity Sensor Head with Communications Adapter
CPVC 1 inch NPT
Modbus RTU 30 ft Cable
RT1 1 4 3
(system with local display)
Optional
LD500 Local Display Turbidity Sensor Head with Communications Adapter
Two 2 4-20mA outputs 2 Relays
Modbus RTU 24 VDC
CPVC 1 inch NPT
Modbus RTU 10 ft Cable
LD B B 0 A 1
RT1 1 4 1
NOTE 1: Use a Modbus RTU Communications Adapter for connection to a LD500 Local Display.
NOTE 2: Sensor is integrated into the Interface Module and is not needed as a separate line item.
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
9
Rev 1.3 10-11-10
Communication Adapter Interface Module
Contacting Conductivity / Resistivity Sensor Head
Contacting Conductivity Sensor Head
Model Number
CC Two Electrode Conductivity Sensor Head plugs into any AdvantEDGE Interface Module and provides factorycalibrated measurement. Integral Temperature.
Body Material
2 CPVC (Low Cost, All Purpose)
3 PEEK® (Food Grade, High Temperature)
Electrode Material
1 Titanium (Standard)
2 316 Stainless Steel
Cell Constant
A 0.1 Cell Constant (500 μS/cm Range. PEEK® Material Recommended)
B 1.0 Cell Constant (500 μS/cm Range.
D 0.01 Cell Constant (Resistivity to 50 μS/cm Range. PEEK® Material Required)
CC
AdvantEDGE System
Components
Interface Module
Contacting Conductivity Sensor Head Part Number
Description Part Number
Reference
Communications Adapter
Profibus Gateway Adapter
316 Stainless Steel 1” sensor body
CPVC 1-inch sensor body
PEEK® 1-inch sensor body
IM11
IM21
IM31
CPVC Modbus RTU with 10 foot cable CA22B1A
Modbus RTU AdvantEDGE connects to Profibus DP PA26R
Page 1
Page 2
Page 16
Local Display Description
LD500 Local Display One 4-20mA output, PID. 24VDC.
One 4-20mA output, PID. 100 – 240 VAC
Two 4-20mA outputs, PID, 2 Relays, Modbus Host, 24VDC.
Two 4-20mA outputs, PID, 2 Relays, Modbus Host,100-240VAC
Conductivity Solutions and Replacement Parts
Product Description
Calibration Solution
Calibration Solution
Calibration Solution
Cleaning Solution
Protective Cap
1000 μS/cm – 500ml bottle
2000 μS/cm – 500ml bottle
5000 μS/cm – 500ml bottle
Conductivity Electrode Cleaner – 500ml bottle
Protective Cap for Contacting Cond. Electrodes
Part Number
Reference
LDBB0A1
LDBB0A2
LDCB4C1
LDCB4C2
Page 15
Part No.
SOL1000
SOL2000
SOL5000
SOL2C
SBC01
Common Contacting Conductivity Measurement Systems
(system without local display)
Communication Adapter Interface Module Conductivity Sensor Head
CPVC Body
Modbus RS-232 30 ft of cable
CPVC Body
1-inch NPT
CPVC Titanium Electrode
1.0 Cell Constant
CA 2 2A 3 A IM 2 1 CC 2 1 B
Optional
LD500 Local Display
(system with local display)
Communication Adapter
Interface Module
Conductivity Sensor Head
One 4-20 output 24 VDC
Modbus RTU No Relays
LD B B 4 A 1
CPVC Body
Modbus RTU 10 ft of cable
CA 2 2B 1 A
CPVC Body
1-inch NPT
IM 2 1
NOTE 1: Table above shows selected Interface, Com. and LD500 components. See referenced pages for options.
NOTE 2: Refer to data sheet for mounting hardware configuration details.
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
10
CPVC Titanium Electrode
1.0 Cell Constant
CC 2 1 B
Rev 1.3 10-11-10
Communication Adapter Interface Module Torodial Conductivity Sensor Head
Toroidal Conductivity Sensor Head
Model Number
TC Toroidal Conductivity Sensor Head plugs into any AdvantEDGE Interface Module and provides factory-calibrated measurement. Integral temperature.
Body Material
2 CPVC (Low Cost, All Purpose)
3 PEEK® (Food Grade, High Temperature)
TC Toroidal Conductivity Sensor Head part number
AdvantEDGE System
Components
Interface Module
Communications Adapter
Profibus Gateway Adapter
Description Part Number Reference
Page 1 316 Stainless Steel 1” sensor body
CPVC 1-inch sensor body
PEEK® 1-inch sensor body
IM11
IM21
IM31
CPVC Modbus RTU with 10 foot cable CA22B1A
Modbus RTU AdvantEDGE connects to Profibus DP PA26R
Page 2
Page 16
Local Display Description
LD500 Local Display One 4-20mA output, PID. 24VDC.
One 4-20mA output, PID. 100 – 240 VAC
Two 4-20mA outputs, PID, 2 Relays, Modbus Host, 24VDC.
Two 4-20mA outputs, PID, 2 Relays, Modbus Host,100-240VAC
Conductivity Solutions and Replacement Parts
Product
Calibration Solution
Calibration Solution
Calibration Solution
Cleaning Solution
Description
1000 μS/cm – 500ml bottle
2000 μS/cm – 500ml bottle
5000 μS/cm – 500ml bottle
Conductivity Electrode Cleaner – 500ml bottle
Part Number Reference
LDBB0A1
LDBB0A2
LDCB4C1
LDCB4C2
Page 15
Part No.
SOL1000
SOL2000
SOL5000
SOL2C
Common Toroidal Conductivity Measurement Systems
(system without local display)
Toroidal Conductivity Sensor Head
Communication Adapter
CPVC Body
Modbus RS-232 30 ft of cable
Interface Module
CPVC Body
1-inch NPT
CPVC
CA 2 2A 3 A IM 2 1
TC 2
Optional
LD500 Local Display
One 4-20 output 24 VDC
Modbus RTU No Relays
LD B B 4 A 1
(system with local display)
Communication Adapter Interface Module
CPVC Body
Modbus RTU 10 ft of cable
CA 2 2B 1 A
CPVC Body
1-inch NPT
IM 2 1
Toroidal Conductivity Sensor Head
CPVC
TC 2
NOTE 1: Table above shows selected Interface, Com. and LD500 components. See referenced pages for options.
NOTE 2: Refer to data sheet for mounting hardware configuration details.
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
11
Rev 1.3 10-11-10
Communication Adapter Interface Module Dissolved Oxygen Sensor Head
Dissolved Oxygen Sensor Head
Model Number
DO31 Dissolved Oxygen (ppm) Sensor Head plugs into any AdvantEDGE Interface Module and provides factory-calibrated measurement. Integral Temperature. Replaceable membrane cap. PEEK® Body.
Sensor Tip Options
A Protected membrane (Standard)
B Process Flat (without face seal)
C Face Seal (for flow chamber mounting)
Reserve Category
Membrane Options
A FEP Teflon (Standard)
B Membrane w/SS mask to protect membrane from particles and pressure
DO31 1
Dissolved Oxygen Sensor Head part number
AdvantEDGE System
Components
Interface Module
Description Part Number
Reference
Communications Adapter
Profibus Gateway Adapter
316 Stainless Steel 1” sensor body
CPVC 1-inch sensor body
PEEK® 1-inch sensor body
IM11
IM21
IM31
CPVC Modbus RTU with 10 foot cable CA22B1A
Modbus RTU AdvantEDGE connects to Profibus DP PA26R
Page 1
Page 2
Page 16
Local Display Description
LD500 Local Display One 4-20mA output, PID. 24VDC.
One 4-20mA output, PID. 100 – 240 VAC
Two 4-20mA outputs, PID, 2 Relays, Modbus Host, 24VDC.
Two 4-20mA outputs, PID, 2 Relays, Modbus Host,100-240VAC
Dissolved Oxygen Accessories and Electrolyte
Product
ppm electrolyte
Protected Cap
Protected Cap & Mask
Storage Cover
Description
Electrolyte in ppm range – 60ml bottle
Protected Cap with Pre-stitched membrane
Protected Cap with Pre-stitched membrane & mask
To keep stored membrane wet when stored
Part Number
Reference
LDBB0A1
LDBB0A2
LDCB4C1
LDCB4C2
Page 15
Part Number
RDOK1
DMR03
DMR03M
SBC01
Common Dissolved Oxygen Measurement Systems
(system without local display)
Communication Adapter Interface Module
Dissolved Oxygen Sensor Head
CPVC Body
Modbus RS-232 30 ft of cable
CPVC Body
1-inch NPT
CPVC Protected Membrane
FEP Teflon
CA 2 2A 3 A IM 2 1
DO31 A 1 A
Optional
LD500 Local Display
One 4-20 output 24 VDC
Modbus RTU No Relays
LD B B 4 A 1
(system with local display)
Communication Adapter
Interface Module
CPVC Body
Modbus RTU 10 ft of cable
CA 2 2B 1 A
CPVC Body
1-inch NPT
IM 2 1
Dissolved Oxygen Sensor Head
CPVC Process Flat
FEP Teflon
DO31 B 1 A
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
12
Rev 1.3 10-11-10
Communication
Adapter not needed
Interface
Module not needed
Optical Dissolved Oxygen RDO Sensor
Model
OPDO
Optical Dissolved Oxygen Sensor Assembly. 0-20 PPM (mg/1), 0-200% saturation. Integrated temperature compensation.
Communications
1
2
For connection to LD500 Local Display. See LD500 options below and on Page 15.
4-20 mA, Modbus (RS-485), SDI-12. For connection to PLC or SCADA.No Local Display.
Cable Connection Type
C
Titanium connector at back end of Sensor body. Order cable separately. See Accessories.
D
Cable permanently attached to Sensor body.
Cable Length
3
30 Feet. For permanently attached cable.
X
Where X = Number of Feet / 10. For permanently attached cable.
N
No Cable. For Sensor having titanium connector. Order cable separately. See Accessories
OPDO
Optical Dissolved Oxygen Sensor Assembly part number
Local Display Options For
OPDO “1” Configurations
LD500 Local Display
Description
One 4-20 mA output, 24 VDC
One 4-20 mA output, 100 – 240 VAC
Two 4-20 mA outputs, 2 Relays, Modbus Master, 24 VDC
Two 4-20 mA outputs, 2 Relays, Modbus Host, 100-240 VAC
Part
Number
LDBB0A1
LDBB0A2
LDCB4C1
LDCB4C2
OTHER HOST COMMUNICATIONS OPTIONS AVAILABLE. SEE PAGE 16
Reference
Page 15
Product Description
Sensor Cap Replacement Kit
Cable
O-Ring Replacement Kit
Nose Cone Replacement Kit
Calibration Kit
Replacement Cap Assembly. Must be replaced annually
Includes sensor cap, lubricant and lens wipe
Cable with Titanium Connector for use only with Sensor
With Connector Type “C”
Includes o-ring for sensor body, internal nose cone o-ring, sensor cap o-rings, lubricant and lens wipe
Includes Nose, lubricant, lens wipe, pre-installed o-ring and o-ring for sensor body
Includes Calibration and Storage Chamber, Calibration Cap,
Storage Cap and Sodium Sulfite
Part
Number
DMROP03
-----------
OPORKIT
OPNOSEKIT
OPCALKIT
Common Optical Dissolved Oxygen Measurement Systems
(system with local display)
Optional
LD500 Local Display Optical Dissolved Oxygen Sensor Assembly
One 4-20 output
24 VDC
LD B B 0 A 1
For LD500
Permanent 30 ft cable
OPDO 1 D 3
(system without local display)
Optical Dissolved Oxygen Sensor Assembly
For 4-20mA, Modbus - No Local Display
Permanent 30 ft cable
OPDO 2 D 3
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
13
Rev 1.3 10-11-10
Communication Adapter Interface Module Dissolved Ozone Sensor Head
Dissolved Ozone Sensor Head
Model Number
OZ31 Ozone Sensor Head plugs into any AdvantEDGE Interface Module and provides factory-calibrated measurement.
Integral temperature. Replaceable Membrane Cap. PEEK
Sensor Tip Options
B Process Flat (Standard)
C Face Seal (For Flow Chamber Mounting)
OZ31 Dissolved Ozone Sensor Head part number
AdvantEDGE System
Components
Interface Module
Communications Adapter
Profibus Gateway Adapter
Description
316 Stainless Steel 1” sensor body
CPVC 1-inch sensor body
PEEK® 1-inch sensor body
Part
Number
IM11
IM21
IM31
CPVC Modbus RTU with 10 foot cable CA22B1A
Modbus RTU AdvantEDGE connects to Profibus DP PA26R
Reference
Page 1
Page 2
Page 16
Local Display Description
LD500 Local Display One 4-20mA output, PID. 24VDC.
One 4-20mA output, PID. 100 – 240 VAC
Two 4-20mA outputs, PID, 2 Relays, Modbus Host, 24VDC.
Two 4-20mA outputs, PID, 2 Relays, Modbus Host,100-240VAC
Part
Number
LDBB0A1
LDBB0A2
LDCB4C1
LDCB4C2
Reference
Page 15
Product
Ozone Electrolyte
Membrane Cap Flat
Membrane Cap Face Seal
Protective Cap
Description
Electrolyte in the ppm range – 60ml bottle
Process Flat for Ozone
Flat cap for O-Ring with pre-stretched membrane
To keep membrane wet when stored
Part
Number
RDOK2
DMR08-Z
DMR04-Z
SBC01
Common Dissolved Ozone Measurement Systems
Communication Adapter
(system without local display)
Interface Module
Dissolved Ozone Sensor Head
CPVC Body
Modbus RS-232 30 ft of cable
CPVC Body
1-inch NPT
PEEK
Process Flat Sensor Tip
CA 2 2A 3 A
IM 2 1 OZ31 B
Optional
LD500 Local Display
(system with local display)
Communication Adapter Interface Module
Dissolved Ozone Sensor Head
One 4-20 output 24 VDC
Modbus RTU No Relays
LD B B 4 A 1
CPVC Body
Modbus RTU 30 ft of cable
CA 2 2B 1 A
CPVC Body
1-inch NPT
IM 2 1
NOTE 1: Table above shows selected Interface, Com. and LD500 components. See referenced pages for options.
NOTE 2: Refer to data sheet for mounting hardware configuration details.
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
14
PEEK
Face Seal
OZ31 C
Rev 1.3 10-11-10
AdvantEDGE LD500 Local Display
Model Number
LD500 Local Display for measurement, calibration and configuration capability of AdvantEDGE systems. Full featured analog output and relay functions. PID function standard with pH and conductivity. pH compensation available with Chlorine.
NEMA 4X Wall mount standard. Panel and pipe mount options available.
Outputs
B One 4-20mA Analog Output Only
C Two 4-20mA Analog Outputs and Two Alarm/Control/Wash Relays (Form C)
Reserved Category
Host Communications
0 None
1 RS-232 ASCII
2 Modbus RS-232
4 Modbus RTU (RS-485). For Modbus and Profibus networks.
5 DeviceNet
6 CanOpen
7 Ethernet IP, Modbus TCP, TCP/IP
Relays
A No Relays
C Two Alarm/Control/Wash Relays (Form C)
Power
1 24 VDC
2 100 to 240 VAC
LD B LD500 Local Display part number
Hardware
¼ DIN Panel Mount
½ DIN Panel Mount
Pipe Mount
AC/DC Power Supply
Sun Shield
Cord Grips
Description
Hardware for mounting in a 3.5” square cutout.
Hardware for mounting in a 5.25” square cutout.
Hardware to mount onto a 2” pipe.
External 100-240 VAC input to 24VDC output.
To protect Display from full sunlight
½ Inch cord grips for conduit boxes (Qty 5)
Part Number
DIN4KIT
DIN2KIT
PIP2KIT
PS24
SUN01
CGRIP01
NOTE 1: Relays are only available when choosing 2 analog outputs.
NOTE 2: For Profibus DP (V0/V1), configure the LD500 with Modbus RTU Host Communications and purchase a Profibus Gateway Adapter (PN: PA26R on Page 16).
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
15
Rev 1.3 10-11-10
Profibus Gateway Adapter
Model Number
PA500 Profibus Gateway Adapter connects up to 30 Modbus Communications Adapter to a Profibus DP (V0 or V1) network with M12 connector. Full-featured measurement, calibration, configuration and diagnostics. 24 VDC
Power.
Reserve Category
Reserve Category
PA 26 R PA500 Profibus Gateway Adapter part number
Communications Hardware
Profibus Accessories
M12 Profibus Tee Connector
Male Termination Network
Female Termination Network
Female Field-wireable M12 Connector
Male Field-wireable M12 Connector
9-Pin Male D Connector
Profibus Cable
Modbus/DeviceNet Accessories
1 Port Device Tap, DIN Rail
2 Port Device Tap, DIN Rail
4 Port Device Tap, NEMA4X
Multi-port termination resistors
Extension Cable
Ethernet Accessories
Modbus to Ethernet Gateway
Power Injector with Cross Over cable
PoE Switch – Consumer Grade
General Accessories
RS-232 junction w/power and connector
AC/DC Power Supply
AquaComm™ Software
Description
Mating connector for Profibus Gateway Adapter
M12 Termination at the end of the network-Male
M12 Termination at the end of the network-Female
Female field-wireable connection to M12 Tee
Profibus cable connection to M12 Tee
Profibus cable to D connector (usually to PLC)
Profibus network cable (purple).
1 Interface connection on network with DIN rail
2 Interface connections on network with DIN rail
4 Interface connections on network with NEMA4X
Termination for Device Taps at the end of network
Interface extension cable
Up to 32 parameters from multiple Modbus Interface
One Interface plugs in directly for power injection.
8 Interface plugs in directly.
Connect RS-232 Interface to power and computer
External 100-240 VAC input to 24VDC output
PC software for USB and RS-232 Advantage.
Measure, calibrate, configure, diagnose, data log
Part Number
AS-RKSW2RSSW45
AS-RSSW45-TR
AS-RKSW45-TR
AS-BMWS8151-8.5
AS-BMSWS8151-8.5
AS-D9S
PSECxx; xx=ft
AS-810-902/000-001
AS-810-901/000-001
AS-810-900/000-001
MPTR
DSECxx; xx=ft
AS-451EM-D
AS-POE-48i
AS-FS108P
JBOX232
PS24
AquaComm™
NOTE 1: Consult communications hardware data sheet for product descriptions.
NOTE 2: Use Port Device Tap to connect multiple Modbus RTU Communications Adapters to the Profibus Gateway Adapter.
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
16
Rev 1.3 10-11-10
Mounting Hardware
Mounting Hardware
1.5” Union Mount
1.5” Union Mount Assembly
1.5” Tee
Immersion Assembly
Immersion Assembly w/
Swivel Rail Mounting
Immersion Assembly w/
Swivel and Ball Float
1.5” Ball Valve
Flow Chamber Assembly
Ball Float Platform
Wash Hardware
Junction box
Extension Cable
Description
Stainless Steel for Turbidity Sensor
CPVC for Turbidity Sensor
Stainless Steel
CPVC
Schedule 40, Stainless Steel
Schedule 80, CPVC
7 ft PVC extension with junction box – 1” Sensors
7 ft PVC extension with junction box - for Optical DO Sensors
7 ft PVC extension with junction box – 1” Sensors With swivel hand rail mount.
7 ft PVC extension with junction box – 1” Sensors With swivel hand rail mount and inflatable float.
Low Pressure, CPVC
Low Pressure, Stainless Steel
High Pressure, CPVC
High Pressure, Stainless Steel
Flow Chamber with mounting plate w/ kynar fittings.
Dual Flow Chamber with mounting plate w/ fittings.
PVC Float Platform for up to 4 AdvantEDGE Systems
Attach air/water purge block to sensor body. Works with compressor & LD500 wash relay or PLC.
Attach air/water purge block to Optical DO Sensor body.
Works with customer supplied compressor & LD500 wash relay or PLC.
For extension cables. Terminal strip included.
Interface Extension cable
Part Number
MH1041-RT
MH1042-RT
MH1041
MH1042
MH3011
MH3022
MH3083
MH3083-RD
MH1242
MH1252
MH1112
MH1111
MH1122
MH1121
FC002
FC003
MHFB02
MH1222
MH1222-RD
JBOXX01
DSECxx; xx=ft
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
17
Rev 1.3 10-11-10
Guide to Ordering Worksheet pH System
Optional
LD500 Local Display
LD B
Communication Adapter
CA A
ORP System
Optional
LD500 Local Display
LD B
Communication Adapter
CA A
Interface Module
IM 1 PH pH Sensor Head
1A
Interface Module
IM 1 ORP
OPR Sensor Head
1A
Turbidity System
Optional
LD500 Local Display
LD B
Turbidity Sensor Head
RT1
Contacting Conductivity/Resistivity System
Optional
LD500 Local Display Communication Adapter
LD B CA A
Toroidal Conductivity System
Optional
LD500 Local Display Communication Adapter
LD B CA A
Dissolved Oxygen System
Optional
LD500 Local Display
LD B
Communication Adapter
CA A
Interface Module
IM 1
Contacting Conductivity Sensor Head
CC
Interface Module
IM 1
Toroidal Conductivity Sensor Head
TC
Interface Module
IM 1
Optical Dissolved Oxygen RDO System
Optional
LD500 Local Display
Optical Dissolved Oxygen Sensor Head
LD B OPDO
Dissolved Oxygen Sensor Head
DO31 1
Dissolved Ozone System
Optional
LD500 Local Display
LD B
Communication Adapter
CA A
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
18
Interface Module
IM 1
Dissolved Ozone Sensor Head
OZ31
Rev 1.3 10-11-10
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com Rev 1.3 10-11-10
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 5 Typical AdvantEDGE System
- 6 Interface Module
- 7 Communication Adapter
- 8 pH Sensor Head
- 9 pH accessories
- 10 ORP Sensor Head
- 11 ORP accessories
- 12 Free Chlorine Panel Measurement System
- 13 Turbidity System
- 14 Contacting Conductivity Sensor Head
- 15 Toroidal Conductivity Sensor Head
- 16 Dissolved Oxygen Sensor Head
- 17 Optical Dissolved Oxygen Measurement
- 18 Dissolved Ozone Sensor Head
- 19 LD500 Local Display
- 22 Guide to Ordering Worksheet