Optical Dissolved Oxygen RDO Sensor
Model
OPDO
Optical Dissolved Oxygen Sensor Assembly. 0-20 PPM (mg/1), 0-200% saturation. Integrated temperature compensation.
Communications
1
2
For connection to LD500 Local Display. See LD500 options below and on Page 15.
4-20 mA, Modbus (RS-485), SDI-12. For connection to PLC or SCADA.No Local Display.
Cable Connection Type
C
Titanium connector at back end of Sensor body. Order cable separately. See Accessories.
D
Cable permanently attached to Sensor body.
Cable Length
3
30 Feet. For permanently attached cable.
X
Where X = Number of Feet / 10. For permanently attached cable.
N
No Cable. For Sensor having titanium connector. Order cable separately. See Accessories
OPDO
Optical Dissolved Oxygen Sensor Assembly part number
Local Display Options For
OPDO “1” Configurations
LD500 Local Display
Description
One 4-20 mA output, 24 VDC
One 4-20 mA output, 100 – 240 VAC
Two 4-20 mA outputs, 2 Relays, Modbus Master, 24 VDC
Two 4-20 mA outputs, 2 Relays, Modbus Host, 100-240 VAC
Part
Number
LDBB0A1
LDBB0A2
LDCB4C1
LDCB4C2
OTHER HOST COMMUNICATIONS OPTIONS AVAILABLE. SEE PAGE 16
Reference
Page 15
Product Description
Sensor Cap Replacement Kit
Cable
O-Ring Replacement Kit
Nose Cone Replacement Kit
Calibration Kit
Replacement Cap Assembly. Must be replaced annually
Includes sensor cap, lubricant and lens wipe
Cable with Titanium Connector for use only with Sensor
With Connector Type “C”
Includes o-ring for sensor body, internal nose cone o-ring, sensor cap o-rings, lubricant and lens wipe
Includes Nose, lubricant, lens wipe, pre-installed o-ring and o-ring for sensor body
Includes Calibration and Storage Chamber, Calibration Cap,
Storage Cap and Sodium Sulfite
Part
Number
DMROP03
-----------
OPORKIT
OPNOSEKIT
OPCALKIT
Common Optical Dissolved Oxygen Measurement Systems
(system with local display)
Optional
LD500 Local Display Optical Dissolved Oxygen Sensor Assembly
One 4-20 output
24 VDC
LD B B 0 A 1
For LD500
Permanent 30 ft cable
OPDO 1 D 3
(system without local display)
Optical Dissolved Oxygen Sensor Assembly
For 4-20mA, Modbus - No Local Display
Permanent 30 ft cable
OPDO 2 D 3
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916
Phone: 239-337-2116 Fax: 239-332-7643 Toll Free: 888-203-7248
Web: www.hfscientific.com
13
Rev 1.3 10-11-10
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 5 Typical AdvantEDGE System
- 6 Interface Module
- 7 Communication Adapter
- 8 pH Sensor Head
- 9 pH accessories
- 10 ORP Sensor Head
- 11 ORP accessories
- 12 Free Chlorine Panel Measurement System
- 13 Turbidity System
- 14 Contacting Conductivity Sensor Head
- 15 Toroidal Conductivity Sensor Head
- 16 Dissolved Oxygen Sensor Head
- 17 Optical Dissolved Oxygen Measurement
- 18 Dissolved Ozone Sensor Head
- 19 LD500 Local Display
- 22 Guide to Ordering Worksheet