JUNG 211-60GDE is a rotary dimmer with a 2-way push switch designed for use with incandescent lamps and HV halogen lamps. It features a dimming principle of phase cut-off, electronic short circuit protection, and electronic over-temperature protection. Changeover switching is possible when combined with changeover switches. The JUNG 211-60GDE can be used to switch and dim lights in various applications, such as residential, commercial, and hospitality settings.
advertisement
Rotary dimmer with 2-way push switch 60 Hz
Rotary dimmer with 2-way push switch 60 Hz
Art.-No.: 211-60 GDE
Operationsmanual
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and other hazards.
Always disconnect before carrying out work on the device or power supply. In so doing, take all the circuit breakers into account, which support dangerous voltages to the device and or load.
The device is not suitable for disconnection from supply voltage.
Do not connect electronic lamps, e.g. switchable or dimmable energy-saving lamps or
LED lamps. Otherwise the possibility of a device defect cannot be ruled out.
These instructions are an integral part of the product, and must remain with the end customer.
2 Device components
picture 1: Device components
(1) Dimmer
(2) Frame
(3) Central plate
(4) Adjusting knob
(5) Screw terminals
3 Function
Intended purpose
- Switching and dimming incandescent lamps and HV halogen lamps
- Installation in appliance box to DIN 49073
- Suitable for mixed operation up to the specified output (see chapter 6.1. Technical data) i No operation with transformers.
82574103
J:0082574103
1/4 11.08.2009
Rotary dimmer with 2-way push switch 60 Hz
Product characteristics
- Dimming principle, phase cut-off
- Soft locking on actuation
- Electronic short circuit protection
- Electronic over-temperature protection
- Changeover switching possible in combination with changeover switches. i Flickering of the connected lamps due to undershoot of the specified minimum load or through centralised pulses from the power stations and soft humming due to the radio interference suppressor. These are not device faults.
4 Operation
Switch light o Press the adjusting knob.
Adjust the brightness
Light is switched on. o Turn the adjusting knob in the clockwise direction.
The light gets brighter up to maximum brightness. o Turn the adjusting knob in the anti-clockwise direction
Light gets darker to minimum brightness.
5 Information for qualified electricians
5.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before working on the device, disengage all the corresponding miniature circuit breakers. Cover up live parts in the working environment.
Connecting and mounting the dimmer picture 2: Connection diagram o Connect the dimmer (1) according to the connection diagram (picture 2).
82574103
J:0082574103
2/4 11.08.2009
Rotary dimmer with 2-way push switch 60 Hz o Mount the dimmer in the accessory socket. o Mount the frame and the central plate. o Attach the adjusting knob.
Connection in changeover switch i No changeover switch possible with two dimmers. picture 3: Changeover switch
(1) Dimmer
(6) Changeover switch o Connect the dimmer (1) and the changeover switch (6) according to the connection diagram (picture 3).
6 Appendix
6.1 Technical data
Rated voltage
Mains frequency
Ambient temperature
Connected load at 25 °C
Incandescent lamps
HV halogen lamps
Power reduction per 5°C in excess of 25°C
Installation in wooden or dry construction walls
Installation in multiple combinations
Connection
Single stranded
AC 230 / 240 V ~
60 Hz
+5 ... +25 °C
100 ... 1000 W
100 ... 1000 W
-10 %
-15 %
-20 % max. 4 mm²
Power extensions
The symbols used to label the dimmer load shows the load type that can be connected to a dimmer and the electric behaviour of a load: R = ohmic none
82574103
J:0082574103
3/4 11.08.2009
Rotary dimmer with 2-way push switch 60 Hz
6.2 Troubleshooting
The devices switches the load off and only on again after some time.
Over-temperature protection has tripped.
Reduce the connected load.
Check the installation situation. i Automatic switch-on after cooling.
The device switches the load off and cannot be switched on again.
Short-circuit protection has tripped.
Eliminate short-circuit. i After elimination of the short circuit, automatic switch-on. Short-circuit protection is not based on a conventional fuse, no metallic separation of the operational current.
6.3 Warranty
We reserve the right to make technical and formal changes to the product in the interest of technical progress.
We provide a warranty as provided for by law.
Please send the unit postage-free with a description of the defect to our central customer service office:
ALBRECHT JUNG GMBH & CO. KG
Service Center
Kupferstr. 17-19
D-44532 Lünen
Service-Line: +49 (0) 23 55 . 80 65 51
Telefax: +49 (0) 23 55 . 80 61 89 [email protected]
General equipment
Service-Line: +49 (0) 23 55 . 80 65 55
Telefax: +49 (0) 23 55 . 80 62 55 [email protected]
KNX equipment
Service-Line: +49 (0) 23 55 . 80 65 56
Telefax: +49 (0) 23 55 . 80 62 55 [email protected]
The Œ symbol is a free trade symbol, which is solely intended for the authorities and does not guarantee any properties.
ALBRECHT JUNG GMBH & CO. KG
Volmestraße 1
D-58579 Schalksmühle
Telefon: +49.23 55.8 06-0
Telefax: +49.23 55.8 06-1 89
E-mail: [email protected]
Internet: www.jung.de
www.jung-katalog.de
82574103
J:0082574103
4/4 11.08.2009