JUNG 254UDIE1 Universal rotary dimmer insert 50 – 420 W/VA Operating instructions

Add to My manuals
6 Pages

advertisement

JUNG 254UDIE1 Universal rotary dimmer insert 50 – 420 W/VA Operating instructions | Manualzz

Light Management

Universal rotary dimmer insert, incremental control

Art.-No.: 254 UDIE 1

Satellite rotary dimmer insert, incremental control

Art.-No.: 254 NIE 1

Operationsmanual

1 Safety instructions

Electrical equipment may only be installed and fitted by electrically skilled persons.

Failure to observe the instructions may cause damage to the device and result in fire and other hazards.

Danger of electric shock. Always disconnect before carrying out work on the devise or load. At the same time, take into account all circuit breakers that supply dangerous voltage to the device or load.

Danger of electric shock. Device is not suitable for disconnection from supply voltage.

The load is not electrically isolated from the mains even when the device is switched off.

Fire hazard. For operation with inductive transformers, each transformer must be fused on the primary side in accordance with the manufacturer's instructions. Only safety transformers according to EN 61558-2-6 may be used.

Do not connect any electronic lamps, e.g. switchable or dimmable compact fluorescent lamps or LED lamps. Device can be damaged.

These instructions are an integral part of the product, and must remain with the end customer.

2 Device components

picture 1: Device components

(1) Dimmer

(2) Frame

(3) Central plate

(4) Control button

(5) Measuring points for voltage test

(6) Release lever for plug terminal

32534733

J:0082534733

1/6 19.08.2010

Light Management

3 Function

Intended use

- Switching and dimming of incandescent lamps, HV halogen lamps and dimmable inductive transformers or Tronic transformers with halogen lamps

- Suitable for mixed operation up to the specified output (see chapter 6.1. Technical data)

- Installation in appliance box acc. to DIN 49073 i No mixed operation of Tronic and inductive transformers.

Product characteristics

- Connection of more than one dimmer is possible

- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest

- Electronic over-temperature protection

- Bulb-preserving soft start

- Power extension through power boosters (see power booster instructions)

- Automatic setting of the dimming principle suitable for the load

Load type

Incandescent lamps

HV halogen incandescent lamps

Tronic transformers with halogen lamps dimmable inductive transformers with halogen lamps

Electrical behaviour ohmic ohmic capacitive inductive

Dimming principle

Phase cut-off

Phase cut-off

Phase cut-off

Phase cut-on i Flickering of the connected lamps due to undershoot of the minimum load or through centralised pulses from the power stations. Brief flickering upon load detection of ohmic loads. No operation is possible during load detection. These are not device faults.

4 Operation

Switch light o Press the control button.

Light is switched on again with the last brightness level set or switched off.

Switching the light on with minimum brightness

32534733

J:0082534733 picture 2: Minimum brightness

2/6 19.08.2010

Light Management o Turn control button a quarter turn in the anti-clockwise direction and press control button

(picture 2).

Switching the light on with maximum brightness picture 3: Maximum brightness o Turn control button a quarter turn in the clockwise direction and press control button

(picture 3).

Adjusting the brightness

Light is switched on. o Turn the control button in the clockwise direction.

The light gets brighter. o Turn the control button in the anti-clockwise direction.

Light gets darker. i The dimmer detects the turning speed: with quick turning there is 360° between minimum and maximum brightness, with slow turning 720°.

5 Information for electrically skilled persons

5.1 Fitting and electrical connection

DANGER!

Electrical shock when live parts are touched.

Electrical shocks can be fatal.

Before carrying out work on the device or load, disengage all the corresponding circuit breakers. Cover up live parts in the working environment.

32534733

J:0082534733

3/6 19.08.2010

Light Management

Connecting and mounting the dimmer picture 4: Connection diagram for dimmer with extension o Remove approx. 15 mm of insulation from the connecting cables. o Connect dimmer (1) and optionally an extension (7) according the connection diagram

(picture 4). o If multiple miniature circuit breakers supply dangerous voltages to the device or load, couple the miniature circuit breakers or label them with a warning, to ensure release is guaranteed. o Install the device in the appliance box. Fit dimmer in appliance box, connection terminals must be at the bottom. o Mount the frame and the central plate. o Attach the control button.

Pull the connecting cable out of the push terminal. picture 5: Releasing plug terminal o Raise release lever (6) as described in illustration and pull out connecting wire (picture 5).

32534733

J:0082534733

4/6 19.08.2010

Light Management

6 Appendix

6.1 Technical data

Universal rotary dimmer insert, incremental control, Art.-No.: 254 UDIE 1

Rated voltage

Mains frequency

Ambient temperature

Connected load at 25 °C

AC 230 V ~

50 / 60 Hz

+5 ... +25 °C i Power specifications including transformer power dissipation. i Operate inductive transformers with at least 85% nominal load. i For ohmic-inductive mixed load, maximum 50% proportion of ohmic load. Otherwise incorrect calibration of the dimmer may result.

Incandescent lamps

HV halogen lamps

50 ... 420 W

50 ... 420 W

Tronic transformers

Inductive transformers

Ohmic-inductive ohmic-capacitive capacitive-inductive

50 ... 420 W

50 ... 420 VA

50 ... 420 VA

50 ... 420 W not permitted

Power reduction per 5°C in excess of 25°C when installed in wooden or dry construction walls when installed in multiple combinations

-10 %

-15 %

-20 %

Power boosters

Connection

Single stranded

See power booster instructions

1.0 ... 2.5 mm²

Number of extension units

Total length of extension unit cable

Total length power cable

The symbols used to label the dimmer load shows the load type that can be connected to a dimmer and the electric behaviour of a load:

R = ohmic, L = inductive, C = capacitive

5 max. 100 m max. 100 m

Satellite rotary dimmer insert, incremental control, Art.-No.: 254 NIE 1

Rated voltage

Mains frequency

Ambient temperature

Connection

Single stranded

Total length of extension unit cable

6.2 Troubleshooting

The device switches the load off briefly and then on again.

Cause: short-circuit protection has tripped but now there is no longer a fault.

AC 230 V ~

50 / 60 Hz

+5 ... +25 °C

1.0 ... 2.5 mm² max. 100 m

The device switches the load off and cannot be switched on again.

Cause 1: short-circuit protection has tripped.

Eliminate short-circuit. i Short-circuit protection is not based on a conventional fuse, no metallic separation of the operational current.

Cause 2: overheating protection has tripped.

Disconnect dimmer from mains, also switch associated off circuit breakers.

Let dimmer cool down for at least 15 minutes.

Reduce the connected load.

32534733

J:0082534733

5/6 19.08.2010

Light Management

Check the installation situation.

Switch circuit breakers and dimmer on again.

6.3 Warranty

We reserve the right to make technical and formal changes to the product in the interest of technical progress.

We provide a warranty as provided for by law.

Please send the unit postage-free with a description of the defect to our central customer service office:

ALBRECHT JUNG GMBH & CO. KG

Service Center

Kupferstr. 17-19

D-44532 Lünen

Service-Line: +49 (0) 23 55 . 80 65 51

Telefax: +49 (0) 23 55 . 80 61 89 [email protected]

General equipment

Service-Line: +49 (0) 23 55 . 80 65 55

Telefax: +49 (0) 23 55 . 80 62 55 [email protected]

KNX equipment

Service-Line: +49 (0) 23 55 . 80 65 56

Telefax: +49 (0) 23 55 . 80 62 55 [email protected]

The Πsymbol is a free trade symbol, which is solely intended for the authorities and does not guarantee any properties.

ALBRECHT JUNG GMBH & CO. KG

Volmestraße 1

D-58579 Schalksmühle

Telefon: +49.23 55.8 06-0

Telefax: +49.23 55.8 06-1 89

E-mail: [email protected]

Internet: www.jung.de

www.jung-katalog.de

32534733

J:0082534733

6/6 19.08.2010

advertisement

Key Features

  • Suitable for mixed operation of incandescent, halogen, Tronic, and inductive loads
  • Electronic short-circuit and over-temperature protection
  • Bulb-preserving soft start
  • Automatic dimming principle adjustment
  • Power extension through power boosters (sold separately)

Related manuals

Frequently Answers and Questions

What types of loads can be connected to the dimmer?
Incandescent lamps, HV halogen lamps, dimmable inductive transformers, and Tronic transformers with halogen lamps
Can I connect multiple dimmers?
Yes, you can connect multiple dimmers to control larger lighting systems
Does the dimmer have any safety features?
Yes, it has electronic short-circuit and over-temperature protection
Download PDF

advertisement