GE PT7800SH3SS Wall Oven/Microwave Combo installation Guide

Add to My manuals
4 Pages

advertisement

GE PT7800SH3SS Wall Oven/Microwave Combo installation Guide | Manualzz
Installation
Instructions
DESIGN INFORMATION
27" & 30" Electric Built-ln Wall Ovens
Questions?
In Canada,
Call 1,800,GE,CARES
call 1,800,561,3344
(1,800,432,2737)
Read these
carefully.
instructions
or visit www,GEAppliances,ca
" IMPORTANT
completely
-- Savetheseinstructions
for local inspector's
" IMPORTANT
and
•
Note to Consumer
- Keep these instructions
for future reference.
•
Skill levelInstallation
of this appliance
requires a qualified
installer or electrician.
•
Proper installation
of the installer.
Note to Installer
instructions
with
- Be sure to leave these
Consumer.
ATTENTION
approved
Product failure due to improper
is not covered under Warranty.
in a cabinet
IMPORTANT: Always refer to irrdividual
requirements.
alone or above a warming
irrstallation
irrstructions
,
Product
is for indoor
F2I
an
braces or runners must be installed to support the weight
of the oven. For single ovens, the runners and braces
must support 200 Ibs (91 kg). For double ovens, the
runners and braces must support 375 Ibs. (170 kg).
installation,
switch
power off at the service panel and
lock the service disconnecting
means to prevent power from being switched
service disconnecting
means cannot be locked, securely fasten a prominent
to the service panel.
on accidentally. When the
warning device, such as a tag,
the marks or opening
NOTE: If the cabinet
for specific
the oven can withstand
Junction
1/8" Drill Bit arrd Electric or Hand Drill
Box
Wire Nuts
Strain Relief Clamp for 1/2" Corrduit
36" (91 ca) of String
from
sides
305" (77.5ca)
observe
30"
models
to establish
_
the cutout
I
_
..........
',
,
I
J
',
]
!
L
I
I
and
dimensions
Cutout
rements,
and
i
requirements
Dimension
Description
27" Single
30" (76.2 cm)
T20 Screwdriver
1/4" Nut Driver
C
Cutout
Height
27%" (70.2 cm) min.
28W' (71.4 ca) max.
271/4" (69.2 cm) min.
27_?' (69.4 ca) max.
CUTOUT
3/4"l1.9 cm)
hick, shim
FOR DOUBLE OVENS (with
NOTE: If the cabinet does not have a front frame
both sides equally to establish
the cutout width.
Upper
and the sides are less than
Microwave
1" (2.5 cm)
1Xd' (1.75 cm)
E
Clearance
to
Adjacent
Corners,
Drawers,
Walls, etc.,
When Door Is Open
23" (58.4 cm) min.
23" (58.4 cm) min.
F
Overlap
of Oven
Top of Cutout
1" (2.5 cm) min.
1" (2.5 cm) min.
(11A" (3.2 cm) for PT9050)
G
Overlap
Bottom
of Oven
of Cutout
1" (2.5 cm) min.
11/4" (3.2 cm)
8_" (22.2 cm) max.
right side only
91//' (24.1 cm) max.
right side only
Junction
3/4"(1.9 cm) thick, shim
For double oven with
so that the upper
t
•
If cabinet
shims
•
_28" (71.1 ca)
microwave
or Advantium
oven can be secured
is at maximum
to bring cabinet
upper
ovens.
to the cleat with
provided
width
cabinet
condition,
to minimum
is in minimum
t
Cabinet
27" (68.6 ca)
30" (76.2 ca)
30" (76.2 ca)
B
Cutout
Width
25" (63.5 ca) rain.
25X" (64.1 ca) max.
28W' (72.4 ca) rain.
28%" (72.7 ca) max.
28Y/' (72.4 ca) rain.
28%" (72.7 ca) max.
C
Cutout
Height
491_t/' (126.2 cm) min.
50W' (127.3 ca) max.
51 _:_6" (131.6 ca) min.
511_6" (131.9 ca) max.
50 W' (127.64cm)
Overlap of Oven
Over Side Edges
of Cutout
1" (2.5 ca)
1Xd' (1.75 ca)
1Xd' (1.75 ca)
Clearance to
Adjacent Corners,
Drawers, Walls, etc.,
When Door Is Open
23" (58.4 ca) rain.
Overlap of Oven
Top of Cutout
1" (2.5 ca) rain.
Overlap of Oven
Bottom of Cutout
1" (2.5 cm) rain.
Description
with
A
F
G
rain.
23" (58.4 ca) rain.
1" (2.5 ca) rain.
(1X" (3.2 cm) for P19550)
1" (2.5 ca) rain.
(1X" (3.2 cm) for P19550)
1X" (3.2 cm)
1X" (3.2 cm)
H
Junction
Box
Location
8¾" (22.2 cm) max.
right side only
9Y/' (24.1 cm) max.
right side only
9Y/' (24.1 cm) max.
right side only
J
Height to Bottom
of Junction
Box
44" (111.8 ca)
47" (119.4 ca)
47" (119.4 ca)
K
Continue
Recommended
Cutout Location
from Floor
to Section
Cabinet
B
Cutout
C
Cutout
Width
Height
D
Overlap
E
Clearance
to Adjacent Corners,
Drawers, Walls, etc., When Door
Is Open
F
G
H
Continue
of Oven Over Side Edges
of Cutout
Overlap
Overlap
of Oven Top of Cutout
of Oven Bottom
Junction
to Section
27" Oven
Microwave
27" (68.6 ca)
Width
of Cutout
Box Location
installing
a Warming
grounded
receptacle
the Warming Drawer
A
Dim.
23" (58.4 ca)
the oven only with
NOTE: Additional
clearances
above the Warming
Drawer
30" Double Oven
without Pedestal
to side of cabinet
screws
cabinet
condition,
is in minimum
with
41W' (104.5 crn) rain.
41X" (104.8 cm) max.
42_d' (107.2 cm) min.
42X" (107.3 cm) max.
1" (2.5 cm)
11A6"(1.75 cm)
23" (58.4 cm) rain.
23" (58.4 cm)
1" (2.5 ca)
rain.
Dimension
3 for DWO with
(33.7 ca)
Pedestal.
12" (30.5 ca)
Otherwise,
continue
to Section
Description
27" Single
Oven
30" Single
Oven
25" (63.5 cm) min.
25X" (64.1 cm) max.
281//' (72.4 cm) min.
28%" (72.7 cm) max.
B
Cutout
Height
27%" (70.2 cm) min.
28W' (71.4 ca) max.
271/4" (69.2 cm) min.
27_6" (69.4 ca) max.
Top
1" (2.5 cm)
1" (2.5 cm)
(I X" (3.2 cm) for PT9050)
Bottom
1" (2.5 cm)
11/4" (3.2 cm)
Side Edges
1" (2.5 cm)
1X6" (1.75 cm)
8¾" (22.2 cm) max.
right side only
91/z'' (24.1 cm) max.
right side only
Unit Overlap
Unit Overlap
Unit
F
Overlap
Junction
to Section
Box Location
4.
PEDESTAL RAIL INSTALLATION (30" DOUBLE OVENS ONLY)
A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom
flush with side of cabinet opening. Locate each rail so that front of rail is behind front cabinet
opening.
B. Drill pilot holes and attach
rails to runner
or bottom
of cabinet
with
provided
hardware.
3.0"
t
Wood
Cleats
27.5"
fix the wood
on 30" cabinet
cutout
condition
specific:
models
listed on the label located
on top of the oven.
Drawer
below
a single
or double
must be installed. Refer to installation
for specific: installation
requirements.
oven, a separate
instructions
120V, 60 HZ, properly
packed
.......-_-_----____
with
...........111
-
DOOR REMOVAL
1
NOTE: Door removal
To remove
Anti-Tip
Block Against
Rear Wall Per Warming
Drawer Requirement
//
_///
for installation
of the product
but is an added
C. Push both hinge
This may require
HANDLE!
position
1" (2.5 ca) rain.
11A" (3.2 ca)
Per Warming
Drawer
Requirement
from front frame
door functionality
locks down
a flat-blade
on both
Hinge Bracket
and set aside. The hinge
when door is reinstalled.
bracket
must
toward the door frame to the unlocked position.
screwdriver.
DO NOT LIFT THE DOOR BY THE
sides of the door and (:lose the oven door to the removal
(approximately
1 "-2"
[2.5 cm-5.1
cm] from
the closed
E. Lift the door up and out until the hinge arms (:lear the slots.
NOTE: The oven door is very heavy. Be sure
you have a firm grip before lifting the oven door offthe hinges.
once the door is removed. Do not lay the door on its handle.
This could cause dents or scratches.
4.
I!_
Hinge Unlocked
position).
Use caution
Position
12" (30.5 ca)
4.
to Section
convenience.
the door:
A. Open the oven door as far as it will go.
2" (5.1 cm)
Min.
91½" (24.1 cm) max.
right side only
(RECOMMENDED)
is not a requirement
B. Remove hinge bracket
be replaced for proper
Continue
4
Hinge Arm
J31-10965-1J 0s-14GE
oven in
Width
E
l_]
over either
Cabinet
/_
13X"
crn)M_n
A
D. Place hands
8¾" (22.2 cm) max.
right side only
(51
between cutouts may be required. Check to be sure the oven supports
location do not obstruct the required interior depth and height.
30" (76.2 ca)
28Y/' (72.4 cm) rain.
28%" (72.7 cm) max.
min.
'r
30" Oven
Microwave
25" (63.5 cm) rain.
25X" (64.1 cm) max.
1" (2.5 ca)
2
m
6.375"_
add wood
condition.
when
_
CUTOUT FOR INSTALLATION OVER A WARMING DRAWER
Minimum
NOTE: Install
A
E
cleat
•1=1.6" _,
when
If cabinet is at maximum
width
cleats as shown in illustration.
When
D
requirements.
Min,
(59,7 cm) Min,
Width
requirements.
Continue
OVEN TO CABINET
Secure a wooden
Cleat locations
with maximum
Depth
Cutout - observe
all dimensions
and
D
Box Location
27" Cabinet
requirements
• No shims (or cleats) required
width condition.
Junction
Box
Location
(junction
box
/
may be
located
in adjacent
cabinet)
may
30" Double Oven with
Pedestal
"!
Cutout - observe
all dimensions
and
C
SECURING UPPER MICROWAVE/ADVANTIUM
Oven)
H
B
23 1/2"
Oven
" (68.58cm) 27" models
Dimension
Overlap of Oven Over
Side Edges of Cutout
H
• (59.7 ca)
27" Double
!
Line
NOTE: One cooktop may be centered
the side-by-side
installation.
D
G
Description
Center
305" (77.5ca) 30" models
Oven
281//' (72.4 cm) min.
28%" (72.7 cm) max.
J
Dim.
30" Single
27" (68.6 cm)
located
in adjacent
Cutout
Oven
25" (63.5 cm) min.
25X" (64.1 cm) max.
(hinge bracket)
Width
30" Cabinet
requirements
* No shims (or cleats) required
width condition.
_
Line
I
I
I
Width
cahinet)
_----_"
200 Ibs. (90 kg) FOR SINGLE OVENS
375 Ibs. (170 kg) FOR DOUBLE OVENS
all
F
-""
Center
Cutout
D-_
SUPPORT
SUPPORT
Side-by-Side
Installations
two ovens in separate cutouts.
Install
Cabinet
_
MUST
MUST
b--
B
/box
_ - __ -
1
of oven
_l
Location
(junction
/be
32 1/2" (82,6ca)
A
Junction
Box
_1
Recommended
Cutout
Location
from Floor
ca)
u
observe
Dimension
i_jdth.
_'I
_ "1
.
i
35" (91.4 cm)
Countertop
Height
A
2T' (68.5Bca)
27" models
all
dimensions
Cutout
Failure to remove packaging
materials could result in damage
to the appliance.
Remove all packing
parts from oven, racks and heating elements. Remove protective film and labels on the outer door
and control panel. Also, remove plastic: on trims and panel, all tape around the oven and any shipping
screws securing the oven to the base pad. Open oven door and remove literature
pack and oven
racks. Remove the bottom trim from the top of the oven. It will be installed at the end of the installation
process. The trim is wrapped separately
and taped to the top of the unit. Remove pedestal rails from
seperate box and set aside (30" Double Wall Ovens Only).
both sides equally
m
Phillips Screwdriver
Wire Strippers
7/18" Nut Driver
and the sides are less than
Gas and Electrical
Connections
for Gas Cooktop
Must be Located
in an Adjacent
Accessible
Location
to the Right
v
........
t
Sided)y
Side Installations
Install two ovens
in separate
cutouts
Center
Line
Center
Line
y
_t
FOR DOUBLE OVENS (2 THERMAL OVENS)
240W208V
Junction
Box
Location (junction
box may be
in adjacent cabinet)
C
G
side
edges
door
REMOVE PACKAGING MATERIALS
does not have a front flame
LJ='_
Allow
1/4" (064
clearances
req
TOOLS YOU MAY NEED
on the unit.
This Oven.
B
the heat
MATERIALS YOU MAY NEED
as labeled
F
22" (55.9
cm) Min to
Bottom of
Junction
Box
Note:
Suitable
Bracing
to Support
models
(597 ca) Min
Be sure the oven is securely irrstalled in a cabinet that is firmly attached to the house structure.
Weight on the oven door could cause the oven to tip arrd result in irrjury. Never allow anyorre to climb, sit,
stand or hang on the oven door.
around
"_='_
Cutout Depth
!
Make sure the wall coverings, counters and cabinets
(up to 200°F [93.3°C]) generated by the oven.
Over
See Cooktop installation
Instructioms for Cutout Size.
See Label on Top of Oven for Approved
Models•
....................
and
the sides are less than 3/4" (1.9 cm) thick, shim both
equally to establish the cutout width.
Be Installed
the specific:
in a d acent
cabinet)
are covered.
does not have a front frame
May
under
25" (63.5 ca)
NOTE: If marks, blemishes or the cutout opening are
visible above the installed oven, it may be necessary to
add wood shims under the runners and front trim until
^-.WARNING:Before
beginning
the
Cooktops
to be installed
(junction
2" x 4"(5 cm x 10 cm)
or Equivalent Runners Level
with Bottom of Cutout
and Flush with Bides of Cutout
two
NOTE: These ovens are only approved
Gas or Electric
Opening
Between Inside
Walls Must he
at Least 28 1/2"
(72,4 ca) Wide
does not have a solid bottom,
3/4"(1.9 cm) thick, shim
H
Junction
Box
Location
PREPARE THE OPENING
NOTE: If the cabinet
FOR YOUR SAFETY:
CUTOUT
width.
use only.
A, electric: wall ovens must be hard-wired
(direct-wired)into
box. A plug and receptacle
is NOT permitted on these products.
NOTE: If the cabinet
the cutout
and the sides are less than
These ovens
are not
approved for
stackable
installations.
drawer. See the label on top of the
packed with each product
to establish
installation
INSTALLER:
junction
A double oven may be irrstalled
oven for approved models.
CUTOUT FOR SINGLE OVENS- UNDER COUNTER
FOR SINGLE OVENS IN WALL CABINET
does not have a front frame
is the responsibility
,
codes and ordinances.
•
both sides equally
DOUBLE OVEN INSTALLATIONS
use.
-- Observea, governing
NOTE: If the cabinet
The single oven may be installed in a cabinet alone or above a warming drawer. The single oven may also
be irrstalled below a countertop or below specified cooktops. See the label on top of the oven for approved
models.
or visit www,GEAppliances,com
BEFORE YOU BEGIN
CUTOUT
SINGLE OVEN INSTALLATIONS
_!l=(_
Hinge Clears Slot
SHIPPING SCREWS REMOVAL (FOR 30" DOUBLE WALL
OVEN WITH UPPER MICROWAVE OVEN ONLY)
Shipping
screws
must be removed
as shown
in illustration.
[_
ELECTRICAL
REQUIREMENTS
r_
(CONT.)
This appliance must be supplied with the proper voltage and frequency and connected to an irrdividual,
properly grounded branch circuit, protected by a circuit breaker or fuse. See the rating plate located on the
oven frame to determine the rating of the product.
You will need a 1/4" Nut [)river.
MAKE ELECTRICAL CONNECTIONS
[=8-7 FOUR-CONDUCTOR
a, WARNING: Switch power off at the service panel and Iockthe service disconnecting
means to prevent power From being switched
cannot be locked, securely fasten a prominent
to the service panel.
on accidentally. When the service disconnecting
warning device, such as a tag,
means
Place oven on table or platform even with the cutout opening. For a single oven, the platform must support
200 Ibs. (91 kg)i and for a double oven, the platform must support 375 Ibs. (170 kg). Connect the flexible
corrduit to the electrical junction
box as shown below _. Position the corrduit in such a manner that it will
lie behind the unit in a natural loop when the oven is installed <*. You will need to purchase an appropriate
strain relief clamp to complete the connection of the conduit to thejunction
box.
RemoveShipping
ScrewsFrom
Both Sides
Rating P|ate
Location-
,Junction Box
;
NOTE: If residence
A. Cut the neutral
the proper
(white) lead from
length
beginning
irrstallation.
WARNING:Improper connection of alurninum house wiring to copper leads can result
in an electrical
manufacturer's
hazard or fire. Use only corrnectors
recommended
procedure closely.
designed
for joining
copper to aluminum
arrd follow
plate is located
the minimum
recommended
dedicated
circuit
KW Rating
240V
KW Rating
208V
Recommended
Circuit Size
(Dedicated)
<4.8 KW
<4.t KW
20 Amp
4.9 KW-7.2 KW
4.2 KW-6.2 KW
30 Amp
7.3 KW-9.6 KW
6.3 KW-8.3 KW
40 Amp
9.7 KW-12.0 KW
8.4 KW-IO.4 KW
50 Amp
|SLIDE
The 3 power leads supplied with this appliance are suitable for connection to heavier gauge household
wiring. The irrsulation of these 3 leads is rated for temperatures
much higher than the temperature
rating of
the household wiring. The current-carrying
capacity of the conductor is governed by the wire gauge arrd the
temperature
rating of the irrsulation around the wire.
the
Strain Relief Clamp
(not included) Must Be
Used at ,Junction Box
Place Oven on a
•
< Ovens come equipped with a 40" or 54" long conduit. If a longer corrduit is desired, there may be one
available for your model. To check availability or order parts, call 1.800.GE.CARES.
*< Double Oven with upper microwave oven we recommend
install the corrduit to side ofjunction
box as
shown in illustration above.
THREE-CONDUCTOR
NOTE: If residence
in Section
oven and make
unit is level.
SWO's and DWO installations
without
pedestal
•
Drive the color-matched
screws
screws
INTO OPENING
A. Locate
branch circuit,
if local codes
in
[_
__ound
I
_
L
local (:()des, using wire nuts.
and Neutral
'Wires
"",,J "_
,Junction Box
Cover
box cover.
included
oven rack guide
B. Place oven rack guides
C. Install
guides
on cavity
using the 8 provided
Manual
oven (as view
Requirements.
to a three-conductor
with
Pull Out
on String
Loop While
Pushing
the Oven Into
the Cabinet
CONNECTION
for detailed
mounting
hardware.
wall studs with
mounting
!
L bracket
towards
back
of cavity
as shown.
rack installation
REPLACING THE OVEN
and different
DOOR
NOTE: The oven door isheavy. You may need help lifting
the door high enough
to slideitintothe hinge slots.Do not lift
the door by the handle.
A. Lift the oven door by grasping
nuts.
each side.
B. With the door at the same angle as the removal position (approximately
1 "-2" [2.5 cm-5.1 cm] from the closed position), seat the notch of the hinge
rack configuration.
tray in the
arm into the bottom edge of the hinge slot. The notch
be fully seated into the bottom of the slot.
the side flanges.
It is recommended
,Junction Box
Cover
D. When you are sure the conduit
is out of the way, slide the oven
s/4 way back into the opening.
Remove the string by pulling on
one end of the loop.
C,
Drill pilot holes through
OVEN
side of the lower
from the front).
sure that the tray in the
•
side flanges.
see WARNING
OVEN RACK GUIDE INSTALLATION (IF APPLICABLE)
BOTTOM TRIM INSTALLATION
D. See Owner's
a turntable
CIRCUIT
conductors,
B. Connect the oven red lead to the branch circuit red lead
and the oven black lead to the branch circuit black lead
in the opening.
Open the door, place
BRANCH
A. Connect the bare oven ground conductor
with the crimped
neutral (white) lead to the branch circuit neutral (white or gray
color), using a wire nut.
control panel are against the cabinet
frame. Make sure that the oven is (:entered
•
leads are aluminum
5, Electrical
When corrnecting
permit:
• With oven installed, attach the bottom trim through
its mounting
holes in front vertical brace using
two trim screws provided. Bottom trim lip must be placed under flange of bottom air duct.
Slide the oven the remaining
way into
the opening so that the side flanges and
"_
box cover.
C. As you slide the oven back, pull
the string so that the conduit
will lie on top of the oven in a
natural loop. For double oven
with upper microwave
oven pull
conduit so that it sits above left
Support to Assist in
Connecting Conduit
in accordance
OVEN)
nuts.
leads are aluminum
using the oven opening as a
grip.Carefullypush against oven
front frame. Do not push against
outside edges.
[_
new construction
(not existing) utilize
an electric oven in new construction,
prohibit grounding
through the
circuit connections.
SCREWS (UPPER MICROWAVE
local (:()des, using wire
B. Lift
oven intocabinet cutout
DO NOT shorten the flexible corrduit. The conduit strain relief clamp must be securely attached to the
junction
box and the flexible corrduit must be securely attached to the clamp. If the flexible corrduit will not
fit within the clamp, do not irrstall the oven until a clamp of the proper size is obtained.
(:()des which apply in your area. Failure to wire your oven
in a hazardous condition.
If there are no local (:()des, your
National Electrical Code, NFPA No. 70 - latest edition,
Association.
MOUNTING
with
A. Loop (do not tie)a 36" (91cm) stringaround the conduit before the oven isslidinto place.This will
keep the conduit from fallingbehind the oven.
C. Install junction
INSTALL
Gro;nd
protection:
You must use a single-phase, 120/208 VAC or 120/240 VAC,60 Hertz electrical system. If you corrnect to
aluminum wiring, properly installed corrnectors approved for use with aluminum wiring must be used.
Check with your local utilities for electrical
according
to governing codes could result
oven must be wired and fused to meet the
available from the National Fire Protection
Requirements.
on the oven side trim.
We recommend you have the electrical wiring arrd hookup of your appliance corrnected by a qualified
electrician. After irrstallation, have the electrician show you how to disconnect power from the appliance.
Effective ,January 1, 1996, the National Electrical Code requires that
a four-conductor
connection
to an electric oven. When installing
a mobile home, recreational
vehicle or an area where local codes
neutral conductor,
refer to the section on four-conductor
branch
5, Electrical
(white) lead to expose
C. Connect the oven neutral (white) lead to the branch circuit
neutral (white or gray) in accordance
with local (:()des, using
a wire nut.
E. Install junction
Rating
A WARNING: To prevent shock, remove house fuse or open circuit breaker before
in Section
the neutral
""4
[
WARNING:This
app,iance
re.st
be
proper,y
grounded
a, WARNING:To prevent fire or shock, do not use an extension cord with this appliance.
see WARNING
Re-strip
of conductor.
NOTE: If the residence red, black or white
conductors,
see WARNING
in Section 5.
Conduit
ELECTRICAL REQUIREMENTS
the crimp.
B. Attach the appliance
grounding
lead (green or bare copper)
in accordance
with local (:()des. If the residence grounding
conductor
is aluminum,
see WARNING in Section 5.
in accordance
J_
CIRCUIT CONNECTION
conductors,
D. Connect the oven red lead to the branch circuit red lead
and the oven black lead to the branch circuit black lead
i
Use the chart below to determine
BRANCH
leads are aluminum
Fully open the door. If the door will not fully open, the indentation
seated correctly
in the bottom edge of the slot.
D. Push the hinge locks up against
to the locked position.
into the
that the
E. Replace hinge
functionality.
be hand tightened.
of the hinge
bracket.
the front frame
The hinge
bracket
arm must
is not
of the oven cavity,
must be replaced
for proper
door
F. Close the oven door.
Hinge Bracket
Hingein
AWARN
Bottom
_
LockedI1 I/'
MOUNT THE OVEN
Edge of
[
Hinge
I II
l i
i'N
i
s,ot\/tl
0
I N G: Mounting
s( rews
must be use(]. Failure to do so could result
the oven falling out of the cabinet, causing
serious injury.
I
I>/
Position_
in
NOTE: During oven mounting
step, ensure that no
damage is done to oven gasket which lines the
edge of oven cavity.
NOTE: Before drilling the pilot holes, make sure
the oven is pushed as far back into the opening
as it will go and is centered.
Securely Fitted
._
Into Bottom of
Mounting
Hole
Locations
(hole locations
may vary)
The Screws
Must Be a
Minimum of
1/4" (6 ram)
From the
Front of
the Cutout.
ik_\_.'"-.
I[1_
\.
\
.... \\
"-.
Hinge Slot
DWO's with
pedesta
Hinge
Notch
Is
FINAL INSTALLATION CHECKLIST
NOTE: If the cabinet is particle board, you must
use #8 x s/4" particle board screws. These may be
purchased
at any hardware
store.
* Check to make
sure the circuit
* Be sure power
is in service
A. Drill through the mounting
holes (top and
bottom) of the side trim for the #8 mounting
screws provided.
, Check that all packing
could result in damage
heated.
material and tape have been removed. Failure to remove these materials
to the appliance
once the appliance
has been turned on and surfaces have
, Remove
inside
B. Secure the oven cabinet
with
Oven rack
guide shown
in place.
the screws
provided.
all items from
breaker
(RESET) or the circuit
fuses are replaced.
the oven.
, Check to be sure that the mounting
(see Section 10).
, Check that the bottom
is closed
to the building.
trim
screws
is installed
are installed
properly
, Ensure that air duct opening
at bottom
of unit
, Check that oven rack guides
(if applicable)
and flush with the side trim
(see Section
11).
is free of obstructions.
are installed
correctly
and oven racks function
smoothly.
OPERATION CHECKLIST
* Turn on the power to the oven (refer to your
and all cooking functions operate properly.
* See your
Owner's
Manual
for the troubleshooting
* Be sure all of the oven controls
i the
MPORTANT:
bottom trim
If this
must
unitbeisremoved
ever removed
first orfrom
damage
the cabinet
to the trim
or the
willoven
occur.is ever pulled out for service,
J31-10965-1J 0s-140E
Owner's
are OFF before
Manual).
Verify that the bake and broil units
list.
leaving
the oven.
Instrucciones
de instalacion
INFORMACION
Hornos
deparedelectricos
empotrados
de27"y30"
LPreguntas?
Llame al 1,8OO,GE,CARES (1,800,432,2737)
En Canada,
al 1,8OO,561,3344
Ilame
o visite
per complete
y con
INSTALACIONES
Nota
•
instrucciones
para referencia
futura.
Nivel de destreza - La instalacion
de este
aparato
requiere
calificados.
para el use de inspectores locales.
•
" IMPORTANT - Cumpla
con_odos
loscodigos
y
Nota al instalador- Asegurese de dejar estas
instrucciones con el Consumidor.
un instalador
estas
o electricista
El instalador tiene la responsabilidad
efectuar
una instalacion
adecuada.
.
ordenanzas vigentes.
- Conserve
La garantia
provocadas
.
Este producto
interiores.
NOTA: Si el gabinete
IMPORTANTE: Siempre consulte
para requerimientos
especificos.
las instrucciones
de instalaciones
individuales
Yea la etiqueta
enviadas
de la
con cada producto
ILl
solo se debe usar en areas
PARA SU SEGURIDAD:
A ADVE RTE NC ]A: Ant÷s
d÷comenzar,a
insta,aciOn,
desconect÷,a
ene,
g,a
del panel de servicio y bloquee los medics de desconexion para evitar el accionamiento de la energia de manera
accidental. Cuando los medics de desconexion de servicio no pueden bloquearse, coloque sobre
el panel de servicio un dispositivo de advertencia bien visible, come una etiqueta.
El homo debe instalarse bien en un gabinete que se encuentre firmemente sujeto a la estructura de la casa. Si se
coloca peso sobre la puerta del homo, este puede volcarse y provocar lesiones. Nunca permita que nadie se suba,
siente, pare o cuelgue de la puerta del homo.
de
(la caja de
conexiones
puede
hallarse
Guias de 2"x 4" (5 cm x 10 cm)
o equivalentes
a nive| con
el fondo del recorte
Abrazadetas
adeeuadas
-para sostener
las gu_s
b
modelo
30"
30,5"(77,5cm)
i
27'r
(68'58 2711
cm)
modelo
cumpla
las
DimensiOn
HERRAMIENTAS NECESARIAS
A
Caja de conexiones
Tapones de alambre
Abrazadera de alivio de tension para conduct() de 1/2"
36" (91 cm) de cuerda
Broca de perforadora
de 1/8" y perforadora
electrica o de mane
Destornillador
de estrella
B
C
adherido en la parte superior de la unidad. Retire los rieles del pedestal de la caja que esta aparte y dejelos a
un costado (Hornos con Pared Doble de 30 _'Unicamente).
TleRMICOS)
H
de la caja de
conexiones (la caja
de conexiones
puede
Ubicadonha]larse
en un gabinete
UbicaciOn
t
Linea
•
en aberturas
central
!
A
4" (10,2 cm)
separadas.
Linea
%
Placa de protecciOn
central
27" (6858 cm) modelo27"
I
I
(5rl
crn)
Abertura - cumpla
con todas las
dimensiones
y
requerimientos,
mln
Horno
unico
de 27"
Homo
unico
30" (762
de 30"
de la abertura
25" (63,5 cm) min.
25X" (64,1 cm) max.
281//` (72,4 cm) min.
28%" (72,7 cm) max.
Altura
de la abertura
27%" (70,2 cm) min.
28W' (71,4 cm) max.
271/4'' (69,2 cm) min.
27_6" (69,4 cm) max.
Superposicion
del horno
sobre los costados
laterales
de la abertura
1" (2,5 cm)
11A6"(1,75 cm)
Espacio respecto
de esquinas
adyacentes,
cajones, paredes, etc.,
cuando la puerta
esta abierta
23" (58,4 cm) rain.
F
Superposicion
de la
parte superior
del homo
de la abertura
1" (2,5 cm) min.
1" (2,5 cm) min.
(1X" (3.2 cm) para PT9050)
G
Superposicion
de la
_arte inferior del homo
de la abertura
1" (2,5 cm) min.
11/4" (3,2 cm)
H
Ubicacion
de la caja
de conexiones
8¾" (22,2 cm) max.
solo lade derecho
91//' (24,1 cm) max.
solo lade derecho
_l
_
'r
(5rl
c_r,)MiD,
Descripcion de la dimension
Ancho
Altura
C
o Advantium.
Asegure un (ace de
superior pueda set asegurado
al (ace
Horno
unico
de 30"
28Y/' (72,4 cm) min.
28%" (72,7 cm) max.
de la abertura
27%" (70,2 cm) min.
28W' (71,4 cm) max,
271/4" (69,2 cm) min.
27%6" (69,4 cm) max,
de la
superior
1" (2,5 cm)
1" (2,5 cm)
(lY4" (3.2 cm) para PT9050)
de la
inferior
1" (2,5 cm)
11/4" (3,2 cm)
Superposicion
unidad en parte
Superposicion
unidad en parte
E
Superposicion
de la
unidad en costados laterales
1" (2,5 cm)
1_A6"(1 #5 cm)
F
Ubicacion
de la caja
de conexiones
8¾" (22,2 cm) max.
solo lade derecho
91/z'' (24,1 cm) max.
solo lade derecho
en la seccion
4.
INSTALACION DEL RIEL CON PEDESTAL (30" HORNOS DOBLES
ONICAMENTE)
B. Realice agujeros
equipo provisto.
de prueba
y adjunte
3.0"
los rieles a la rodadura
o a la parte
inferior
del gabinete
con el
/
a
en la
de 27"
A. Coloque un riel con pedestal en cada rodadura del gabinete o centrado
en el lade opuesto de la
parte inferior del gabinete solido nivelado con el lateral de la abertura del gabinete. Ubique cada riel
de mode que la parte frontal de los mismos se encuentre
detras del lade frontal de la abertura
del
gabinete.
el gabinete
el gabinete
unico
25" (63,5 cm) min.
25X" (64,1 cm) max.
D
Continue
[_]
Horno
del gabinete
23" (58,4 cm) rain.
B
de ancho
se muestra
2
NOTA: Una estufa puede centrarse sobre cualquier
homo en la instalacion
de lade a lade.
A
Si el gabinete se encuentra
en la condicion
de ancho
maximo, agregue cunas de madera para Ilevar el gabinete
la condicion
de ancho minimo.
Si el gabinete se encuentra
en la condicion
maximo, repare los tacos de madera come
ilustracion,
Abertura - cumpla
con todas las
dimensiones
y
requerimientos.
cm)
Dimension
Requisites
para el gabinete
de 30"
• No se requiere el use de cunas (o tacos) cuando
se encuentre
en la condicion
de ancho minimo.
28" (71,1 cm) m_n.
hasta la parte inferior
de la caja de conextones
LBS. (90 kg) PARA HORNOS UNICOS
LBS. (170 kg) PARA HORNOS DOBLES
lade a lade
cumpla
las
Para homes dobbs come homes superiores (:on microondas
Madera sobre el cos(ado del gabinete, de mode que el homo
con los tornillos
provistos.
•
J
--
COMO ASEGURAREL HORNO MICROONDAS/ADVANTIUM
SUPERIORAL GABINETE
F
200
375
1_30,5" (77,5cm) modelo30" }_'i
Requisites
para el gabinete de 27"
• No se requiere el use de cunas (o tacos) cuando
se encuentre
en la condicion
de ancho minimo.
de la caja
--
Ancho
ABERTURA PARAHORNOS DOBLES(con homo de microondas superior)
NOTA: Si el gabinete no cuenta con un armazon frontal y los lados son menores a un grosor de 3/4"
(1,9 cm), coloque cunas uniformemente
sobre ambos lados para establecer
al ancho de la abertura.
SOSTENER
SOSTENER
Ins(ale dos homes
27" (68,6 cm)
QUITE LOS MATERIALES DE EMPAQUE
PODER
PODER
Instalaciones
del gabinete
E
No quitar los materiales de empaque puede provocar danes al electrodomestico.
Quite todas las partes de
empaque del homo, bandejas y elementos de calentamiento.
Quite la pelicula protectora y las etiquetas de
la puerta exterior y panel de control. Tambien, quite los elementos plasticos de los rebordes y panel, toda la
cinta que cubre el homo y los tornillos de envio que fian el homo a la almohadilla
base. Abra la puerta del
homo y quite el material informative y las bandejas del borne. Quite el reborde inferior de la parte superior del
borne. Se colocara al final del proceso de instalacion. El reborde se encuentra envuelto en forma separada y
DEBE
DEBE
horno
Ancho
D
36" (91,4 cm)
Altura del mostrador
de encimera
desde
el piso
32 1/2" (826 cm)
b----
Descripcion de la dimension
de bisagra)
Las conexiones
de gas
y el_ctricas para estufas
a gas deben ubicarse
en
una ubicacion
adyacente
accesible
sobre la derecha.
F
22" (55,9 cm) rain.
sobre la plataforma
dimensiones
y
requerimientos,
2"
en la etiqueta
!
l
Abertura
con todas
y
se indica
Ubicancion
recomendada
de la abertura
desdelos
lateralesde
la
puerta
del
I!
fi
_,_l,_
Alicates pelacables
Dave de tuercas de 7/16"
_,_
come
C
G
conexiones
extremes
Instalacionesladea la
db'____
en aberturas
sep_t_a'_
_
Li......... tra,
Li......... tra,
Abeltura
con todas
especificos
t
dos homes
dimensiones
requerimientos,
NOTA: Si el gabinete no cuenta con un armazon frontal y los lados son menores a un grosor de 3/4" (1,9 cm),
coloque cunas uniformemente
sobre ambos lados para establecer al ancho de la abertura.
22"
(55,9cm)
rain,hasta
la Ur_==_
parte inferior
de la caja de
Nota: Deje
1/4"(0,64cm)
de espacio
NOTA: Si el gabinete no cuenta con un armazon
frontal y los lades son menores a un grosor de 3/4"
(1,9 cm), coloque cunas uniformemente
sobre ambos
lades para establecer
al ancho de la abertura.
b_jo los modelos
f
t
E _--}-_-
Instab
instalarse
25" (53,5 cm)
F
',
solo pueden
Pueden instalarse
estufas a gas o el_ctricas
sobre este homo.
Vet las instrucciones
de instalacibn
de la estufa para el
tama5o de la abertura.
Ver la etiqueta
de la parte superior del homo para
UbicaciOn de la caja
modelos
aprobados,
de conexiones
de
240V/208V
(la caja de conexiones
puede haHarse en un
gabinete
adyacente)
i
i
y niveladas
costados de I_Labertura
NOTA: Si marcas, imperfecciones
o la abertura
resultaran
visibles sobre el homo instalado, puede
ser necesario agregar cunas de madera bajo las
guias y el reborde frontal hasta cubrir las marcas
o la abertura,
ABERTURAPARAHORNOSUNICOS- BAJO EL MOSTRADORDE ENCIMERA
NOTA: Estos hornos
de la unidad.
i'i ._------B-===_
en un gabinete
adyancente)
MATERIALES QUE PUEDE NECESITAR
/adyacente
de la caja
conexiones
i
i
i
i
u
u
u
',f
Verifique que el revestimiento de las paredes, mostradores y gabinetes ubicados alrededor del homo puedan
soportar el calor (hasta 200°F [93,3°C]) generado per el horno.
DOBLES (2 HORNOS
4
PREPARE LAABERTURA
NOTA: Si el gabinete no cuenta con un rondo solido,
deben instalarse
dos abrazaderas
o guias para
soportar el peso del homo, Para hornos unicos, las
guias o abrazaderas
deben soportar 200 Ibs (91 kgs).
Para hornos dobbs, las guias o abrazaderas
deben
soportar 375 Ibs (170 kgs).
|
Ubicancion
I
entre ]as paredes
nternas
debe ser
(cabbad0
direct0)
dentr0
deunacajadec0nexi0nes
apr0bada,
Enestospr0ductos
NOsepermite
h c0nexi0n
deltip0"enchufe
yreceptacud',
PARA HORNOS
al ancho de la abertura.
La abertura
ATENCION
INSTALADOR:
Todos
loshornos
deparedebctricos
@bencontarconcabbado
deconexi0n
permanente
ABERTURA
frontal y los lades son menores a un grosor de 3/4" (1,9 cm),
sobre ambos lades para establecer
Estos homes
no estan
aprobados
para
instalaciones
apilables.
de
no cubre las fallas del producto
per una instalacion incorrecta.
Destornillador
T20 (soporte
Dave de tuercas de 1/4"
no cuenta con un armazon
coloque cunas uniformemente
DE HORNO DOBLE
Puede instalarse un homo doble solo en un gabinete o sobre un cajon calentador.
parte superior del horno para consul(at los modelos aprobados.
•
" IMPORTANTE - Guarde
e<asinstrucciones
•
GEAppliances,com
al consumidor
ABERTURAPARA HORNOS UNICOS EN UN GABIENTE DE PARED
DE HORNO 0NICe
El horno _]nico puede instalarse solo en un gabinete o sobre un cajon calentador.
El horno _]nico tambien
puede instalarse debajo de un mostrador de encimera o debajo de las estufas especificadas.
Vea la
etiqueta de la parte superior del homo para consul(at los modelos aprobados.
www,GEAppliances,ca,
ANTES DE COMENZAR
Lea estas instrucciones
detenimiento.
o visite
INSTALACIONES
DE DISE--O
6"375"I
i
Ubicaciones
de los tacos en un gabinete
de
30" con la condicion
de abertura
m_xima
G
~
-""
_-_-_/"
?
Profundidadde la
abertura 23-!/2"
,_
(59 7 cm)
UbicaciOn
desde
_
NOTA: Instale el horno solo con
en la parte superior del homo,
mlnlmo
A
Dim.
Descripcion
Homo
doble
de 27"
Homo doble de 30"
con pedestal
Homo doble de 30"
sin pedestal
27" (68,6 cm)
30" (76,2 cm)
30" (76,2 cm)
Dim.
25" (63,5 cm) min.
25X" (64,1 cm) max.
28Y/' (72,4 cm) min.
28%" (72,7 cm) max.
28_½'' (72,4 cm) min.
28%" (72.7 cm) max.
A
491_A6'' (126,2 cm) min.
501/?' (127,3 cm) max.
5113_6" (131,6
cm) min.
511%6" (131,9 cm) max.
50 Y_" (127,64cm)
B
Superposicion
del
homo sobre los
costados
laterales
de
la abertura
1" (2,5 cm)
1X6" (1,75 cm)
Espacio respecto de
esquinas adyacentes,
cajones paredes, etc.,
cuando la puerta esta
abierta
23" (58,4 cm) rain.
Superposicion
de la
parte superior
del
homo de la abertura
1" (2,5 cm) rain.
Superposicion
de
la parte inferior del
homo de la abertura
1" (2,5 cm) rain.
Ubicacion de la caja
de conexiones
8¾" (22,2 cm) max.
solo lado derecho
%½" (24,1 cm) max.
solo lado derecho
%½" (24,1 cm) max.
solo lado derecho
J
Altura hasta la parte
inferior de la caja de
conexiones
44" (111,8 cm)
47" (119,4 cm)
47" (119,4 cm)
K
Ubicacion
recomendada
de la
abertura
desde el piso
13_A'' (33,7 cm)
12" (30,5 cm)
12" (30,5 cm)
A
B
C
D
E
F
G
H
Continue
Ancho
del gabinete
Ancho de la abertura
Altura
de la abertura
a la Seccion 3 para conocer
31-10965-1]
os-_4_E
23" (58,4 cm) rain.
1X6" (1,75 cm)
C
1" (2,5 cm) rain.
(1X" (3.2 cm) para
PT9550)
1X" (3,2 cm)
1X" (3,2 cm)
Ancho
Ancho
Altura
Homo de 27"
con microondas
Homo de 30"
con microondas
del gabinete
27" (68.6 cm)
3(Y (76.2 cm)
de la abertura
25" (63,5 cm) m(n.
25X" (64,1 cm) max.
28V/' (72,4 cm) m(n.
28%" (72,7 cm) max.
411_'' (104,5 cm) min,
41X" (104,8 cm) max.
42_6" (107,2 cm) m(n.
421A '' (107,3 cm) max.
de la abertura
D
Superposicion
del homo sobre los
costados
laterales
de la abertura
1" (2,5 cm)
_Ao" (1,75 cm)
E
Espacio respecto de esquinas
adyacentes,
cajones paredes, etc.,
cuando la puerta esta abierta
23" (58,4 cm) m(r_.
23" (58,4 cm)
23" (58,4 cm) rain.
1" (2,5 cm) rain.
(1X" (3.2 cm) para
PT9550)
Descripci0n
F
G
H
Continue
Superposicion
de la parte superior
del homo de la abertura
Superposicion
del homo
de la parte inferior
de la abertura
Ubicacion
de la caja de
conexiones
en la seccion
ABERTURA PARA INSTALACION SOBRE UN CAJON CALENTADOR
el piso
1" (2,5 cm) m(r_.
1" (2,5 cm) m(r_.
8¾" (22,2 cm) max.
solo lade derecho
91½" (24,1 cm) max.
solo lade derecho
especificos
listados
en la etiqueta
NOTA: Pueden necesitarse
espacios adicionales
entre las aberturas. Verifique
del homo sobre la ubicacion
de cajon calentador
no obstruyan
la profundidad
requeridas.
ubicada
que los soportes
y altura interiores
./
Cuando ins(ale un cajon calentador
debajo de un homo Onico o doble, debe instalarse
un tomacorriente
separado de 120V, 60 HZ (:on adecuada
conexion a tierra. Consulte
las instrucciones
de instalacion
enviadas con el cajon calentador
para requisitos
especificos
de instalacion.
REMOCION
Para quitar
A. Abra
Bloque
anti=volcaduras
contra la pared trasera
segtin requisito
del
cajOn calentador
a la Seccion 4.
no es un requerimiento
de la instalacion
del producto,
pero es una
de la Bisagra
en su totalidad.
C. Presione ambas trabas de la bisagra hacia abajo en direccion del marco de
la puerta basra destrabarlas.
Para esto puede hacer falta un destornillador
de
lades planes, iNO LEVANTE LA PUERTA DE LA MANIJA!
2" (5J era]
ram,
D. Coloque las manes sobre ambos lades y cierre la puerta del horno hasta la posicion
de remocion (aproximadamente
1 "-2" [2,5 cm-5,1 cm] de la posicion de cierre).
desde el piso
21 5/8" (54 9 cm)
4.
Segl_n los requisites
del cajon calentador
en la seccion
/
B. Retire el soporte de la bisagra de la estructura
frontal y d@jelo a un lade. El
soporte de la bisagra debe set colocado nuevamente
para un funcionamiento
apropiado
de la puerta cuando esta Liltima sea reinstalada.
/
UbicaciOn
recomendada
de la abertura
Continue
/
Soporte
del homo
E. Levante la puerta basra que los brazes de la bisagra hayan salido de las ranuras.
NOTA: La puerta del homo es muy pesada. Asegurese de tenet un agarre firme
antes de levantar la puerta del homo de sus bisagras. Tenga cuidado una vez que haya quitado
puerta. No deposite la puerta sobre la manija. Esto puede provocar abolladuras
o rayones.
/ _.I_.
/
de,a isa ra
del DWO con Pedestal. De otra forma, continue
./
la puerta:
la puerta
Ranura
detalles
./
DE LA PUERTA (recomendada)
NOTA: La remocion de la puerta
comodidad
adicional.
T
1" (2,5 cm) m(r_.
1 _A"(3,2 cm)
los modelos
4.
.zo
de,a ,sa ra
_
_
/_
Posicion destrabada
de la bisagra
__'_'__/
La bisagra
sale de la ranura
la
RETIRO DE LOS TORNILLOS DE EMBALAJE (PARA HORNO
F_
DE PARED DOBLE CON HORNO
Este aparato debe recibir el voltaje y fiecuencia adecuados, y debe conectarse a un circuito derivado
individual con adecuada conexion a tierra, protegido pot un interruptor de circuitos o Fusible. Ver la placa de
clasificacion ubicada en el armazon del homo para determinar la clasificacion del producto.
MICROONDAS
SUPERIOR
ONICAMENTE)
Los tornillos de embalaje
destornillador
de ¼".
deben
ser retirados
como
se muestra
en la ilustracion.
Necesitara
REQUISITOS ELECTRICOS (CONT.)
F_
un
Rating Plate
Location ....... ;
RetirelosTornillos
de Embalaje a
Arnbos Lados
REALICE LAS CONEXIONES
[-8-1 CONEXION DE CIRCUITO DERIVADO DE CUATRO
CONDUCTORES
ELECTRICAS
A ADVERTENCIA:
Desconecte
la energia del panel de servicio y bloquee
los medios
NOTA: Si los cables domesticos
de desconexion para evitar el accionamiento
de la energia de manera accidental, Cuando los medios
de desconexion de servicio no pueden bloquearse, coloque sobre el panel de servicio un dispositivo de
advertencia bien visible, como una etiqueta.
de la seccion
!
La placa de clasificacion
lateral
Utilice la tabla de abajo
para determinar
la proteccion
se encuentra
del homo.
de circuito
Clasificacion
de KW
208V
<4,8 KW
4,9 KW-7,2
acuerdo
minima recomendada:
interruptor
de circuitos
antes de comenzar
la instalacion.
A ADVERTENClA:Nna
correxion
irradecuada
decab,eado
domest,co
de
a,um,n,o
con
cables de cobre puede generar un peligro electrico o un incendio. Solo use conectores disenados
cobre con aluminio y siga al pie de la letra el procedimiento
recomendado
del fabricante.
<4,1 KW
20 Amp
40 Amp
50 Amp
B. Levante el homo
KW
8,4 KW-IO,4
KW
Coloque el homo
en un soporte para
ayudar a la conexion
conducto
Los 3 cables de energia suministrados
con este aparato son adecuados para conexiones con cableados
domesticos de calibre mayores. La aislacion de estos 3 cables esta clasificada a temperaturas
mucho mas
elevadas que la clasificacion
del cableado domestico. La capacidad
de transmitir corriente del conductor esta determinada
por el calibre del cable y la clasificacion
de temperatura
de la aislacion alrededor del cable.
La abrazadera del alivio
de tension (no incluido)
debe usarse en la caja de
conexiones
* los hornos vienen equipados con un conducto de 40" o 54" de Iongitud, Si desea un conducto mas largo, puede
haber uno disponibb para su modelo, Para venficar la disponibilidad o solidtar piezas, Ilame al 1,80O,GECAR[S,
NOTA: Si los cables domesticos
son conductores
del conducto al costado de la caja
de aluminio,
dentro de la abertura. Quite el hilo
]alando de un extremo del lazo.
gabinete.
centrado
•
Verifique que el homo
en la abertura.
Abra la puerta,
coloque
•
Perfore orificios piloto
bridas latera les.
Introduzca
las bridas
los tornillos
laterales.
bles a
derivado y el
(:able negro del homo a l cable negro del circuito derivado
con los codigos locales, utilizando tapones de alambre.
_'
de acuerdo
I
_
tlerray
L
"-41_
_neutrales
Tapade
la caja ae
conexiones
C. Instale la tapa de la caja de conexiones.
Instalaciones
DE LA ESTANTER[A
DEL HORNO
COMO VOLVER A COLOCAR LA PUERTA DEL HORNO
(SI
CORRESPONDE)
A. Ubique el equipo
de montaje
B. Posicione el conducto
homo sea instalado.
SWO y DWO sin pedestal
este
C. Instale
I
las guias
de la guia del homo
de modo tal que se apoye
usando
las 8 tuercas
D. Para una instalacion
de estantes
Manual del Propietario.
de montaje
detallada
NOTA: La puerta del homo es pesada. Puede necesitar ayuda para levantar la puerta Io suficiente
como para deslizarla dentro de las ranuras de la bisagra. No levante la puerta de la manija.
incluida.
detras
de la unidad
en un circulo
natural
cuando
provistas.
y una configuracion
a traves
de estantes
diferente,
consulte
el
los tornillos
a mano.
Bisagra en
la posiciorr
INSTALE EL HORNO
bisagra bien
_l
colocada en la
parte inferior de
la ranura de la
bisagra
Deben utilizarse tornillos de montaje. Si no Io hace,
el horno puede caer del gabinete, Io que provocaria
una lesion grave,
NOTA: Si el gabinete es de placa de particulas,
deben utilizarse tornillos #8 x s/4" para dicho
material. Estos pueden adquirirse
en cualquier
ferreteria.
Ubicaciones
de montaje
(las ubicaciones
pueden vanar)
Los tornillos
deben
hallarse a
un minimo
de ¼"
(6 mm) desde
el ffente de
la abertura.
del homo
lados.
de remocion
la posicion de cerrado),
de la bisagra. El soporte
para un funcionamiento
la
frontal
de
de la bisagra debe set
apropiado
de la puerta.
del homo,
][[I[
Lado
inferior de
la ranura
i_
Brazo
III
I
Soporte
de la bisagra
de la Bisagra
_
I[ _'
LL_>
III F.\-- "_
_(_'\_
[ 1'I,.\ ".
"-..."-1
_
"\
Ranura de la bisagra
DWO sin pedestales
LISTA DE CONTROL
FINAL DE LA INSTALACION
• Verifiqueque el interruptorde circuitosse encuentre cerrado (RESET)o que losfusiblesdel circuito
se hayan reemplazado.
• AsegLirese de que haya suministro electricoen el edificio.
A. Perfore a traves de los orificios de montaje
(superiores e inferiores) del reborde lateral
para los tornillos de montaje #8 provistos.
B. Asegure el gabinete
provistos.
de ambos
de trabado
__
Rarrura de la
__
A ADVERTENCIA:
NOTA: Antes de perforar los orificios piloto,
asegurese de que el homo se encuentre
en la posicion final de la abertura
y centrado.
tomandola
introduzca
la muesca del brazo de la bisagra dentro del extremo inferior de
la ranura de la bisagra. La ranura del brazo de la bisagra debe estar bien
colocada en la parte inferior de la ranura.
F. Cierre la puerta
NOTA: Durante el montaje del homo, asegurese
de que no haya danos sobre lajunta
del homo,
que alina el extremo de la cavidad del homo
del homo
E. Reemplace el soporte
colocado nuevamente
de
ajustar
la puerta
D. Presione las trabas de la bisagra hacia arriba contra el armazon
la cavidad del homo, hasta alcanzar la posicion de trabado.
........
de color dentro
A. Levante
C. Abra la puerta pot completo. Si la puerta no se abre pot completo,
muesca no est___bien colocada en el extremo inferior de la ranura.
_-
de las
Se recomienda
el
B. Con la puerta en el mismo angulo de la posicion
(aproximadamente
1"-2" [2,5 cm-5,1 cm] desde
una bandeja
giratoria
dentro del homo y asegurese de
que la bandeja de la unidad este nivelada.
o
A. Conecte el conductor a tierra del homo con el (:able neutral (blanc())
en rizo al neutral del circuito derivado (blanco o gris) utilizando un
tapon de alambre.
• Una vez instaladoel homo, adjunte el borde inferiora traves de sus agujeros de montaje frenteal
soporte vertical,
utilizandolosdos tornillos
con cabeza recortada provistos.El labiode lacubierta
inferior
debera set ubicado debajo de la brida de la parte inferior
del conducto de aire.
C. A medida que desliza el homo
hacia arras,]ale del hilo para que
el conducto quede sobre el homo
(:on un lazo natural. For double
D. Cuando se asegure de que el
conduct() no est@ en el camino,
deslice el horno sA hacia arras
de tres conductores,
GU[A DE INSTALACION
Jale del
lazo de hilo
mientras
empuja el
homo dentro
del gabinete
oven with upper microwave
oven
pull conduit so that it sits above
left side of the lower oven (as
view from the front).
vet la ADVERTENCIA de la seccion 5, Requisitos electricos,
INFERIOR
dentro de la
No presione sobre los bordes
externos.
del
** Para el Homo Doble con homo microondas superior recomendamos la instabdon
de empaimes, como se muestra en [a ilustraciOn anterior.
Imagen de la guia
de la estanteria
en su lugar
correspondiente.
con los tornillos
• Controle que se haya quitado todo el material de empaque y lacinta adhesiva. No quitarestos
materiales puede provocar danos al electrodomestico una vez que el aparato se haya encendido y
lassuperficiesse hayan calentado.
• Quite todos loselementos ubicados dentro del homo.
• Asegurese de que lostornillos
de montaje se encuentren
lateral(verseccion I0).
• Verifique
• Asegurese
que el reborde
inferior
de que la abertura
este bien instalado
inferior
• Controle que las guias de los estantes
y que los estantes del homo funcionen
del conducto
instaladosy nivelados con el reborde
(vet seccion
11).
de aire de la unidad
del homo (si corresponde)
de forma fluida.
esten
este libre de obstrucciones.
instaladas
de forma
LISTA DE CONTROL DE FUNCIONAMIENTO
• Accione la energia del homo (consulte el Manual del propietario).
Verifique
de horneado y asado y que todas las funciones
de coccion operen bien.
• Vet el Manual
IMPORTANTF:
Siesta unidad alguna
reborde inferior debe quitarse antes
J31-10965-1J os44 GE
en su
abertura del gabinete utilizando
el homo abierto como agarre.
Con cuidado empuje contra
el armazon frontaldel horn().
F_l CONEXION DE ClRCUITODERIVADO DE TRESCONDUCTORES
INSTALACION DEL REBORDE
C) (:30)
(:30
rm
DE LA ABERTURA
KW
B. Conecte el cable rojo del homo al (:able rojo del circuito
0
DENTRO
6,3 KW=8,3
Consulte alas empresas de servicio p0blico sobre los codigos electricos que se aplican en su area. No
realizar el cableado de su horno de acuerdo con los codigos vigentes puede provocar una situacion
peligrosa. Si no existen codigos locales, el cableado y Fusibles de su homo deben cumplir con el Codigo
Electrico Nacional, NFPA N ° 70, 01tima edicion, disponible en National Fire Protection Association (Asociacion
Nacional de Proteccion contra Incendios).
00 rmo
OE3 rm_
0 I"--I
(:30
de
7,3 KW=9,6 KW
Vigente desde el 1 de enero de 1996, el Codigo Electrico Nacional re( uiere que las nuevas construcciones
(no existentes) utilicen una conexion de cuatro conductores
a un homo electrico. Cuando instale un homo
electrico en una construccion
nueva, una casa rodante, un vehiculo recreativo o un ___readonde los codigos
locales prohiben la conexion a tierra a traves de un conductor neutral, consulte la seccion sobre conexiones
en circuito derivado de cuatro conductores.
I
de alambre.
la tapa de la caja de conexiones.
DESLICE EL HORNO
Cuando conecte un circuito derivado
si Io permiten los codigos locales:
bridas laterales y el panel de control
se encuentren
contra el armazon del
tapones
A. Enrosque (no ate) un hilode 36" (91 cm) alrededor del conducto antes de deslizarel homo
lugar.Esto no permitiraque el conducto caiga detras del homo.
Usted debe usar un sistema electrico de fase L_nica de 120/208 VAC o 120/240 VAC de 60 hercios. Si tiene
una conexion con cableado de aluminio, deben utilizarse conectores adecuadamente
instalados para
utilizar con cableado de aluminio.
Deslice el homo pot la distancia
que
falta dentro de la abertura
para que las
utilizando
30 Amp
Recomendamos
que un electricista calificado conecte el cableado electrico de su aparato. Despues
de la instalacion, solicite al electricista que le indique como desconectar
la energia del aparato.
•
locales,
KW
para unit
INSTALE LOS TORNILLOS DE MONTAJE (HORNO
MICROON DAS SUPERIOR)
con los codigos
Tapa de
la caja de
conexiones
4,2 KW-6,2
NO acorte el conducto Flexible. La abrazadera del alivio de tension del conducto debe estar bien sujeta a la
caja de conexiones y el conducto Flexible debe estar bien sujeto a la abrazadera. Si el conducto Flexible no
entra dentro de la abrazadera, no instale el homo basra obtener una abrazadera
del tamano adecuado.
A ADVE RTEN CIA: Papa
preven,r
una
desca,ga
e,ectrica,
e,Fus,b,eoab
e, a
de alambre.
Tamaffo de circuito
recomendado
(dedicado)
A ADVERTENCIA:Esto
apa,ato
debo
conta,
con
una
adecuada
corroxionatio.a
A ADVERTENCIA:Pa,apreven,run,ncond,oodoscargao,ec.,ca,
nou ,,icouncab,e
de extension con este aparato.
ea
KW
9,7 KW-12,0
I_] REQUISITOS ELECTRICOS
un tapon
NOTA: Si los cables rqjos, negros o blancos son conductores
aluminio, vet ADVERTENCIA de la seccion 5.
E. Ilnstale
Clasificacion
de KW
24OV
de engarce.
la Iongitud correcta
D. Conecte el (:able rojo del homo al (:able rojo del circuito derivado
y el (:able negro del homo al cable negro del circuito derivado de
en el reborde
dedicado
ver la ADVERTENCIA
C. Conecte el (:able neutral (blanco) del homo (:on el neutral
de circuito derivado (blanco o gris) de acuerdo con codigos
Conducto
D
de aluminio,
B. Conecte el (:able a tierra del artefacto
(verde o cobre)
de acuerdo con los codigos locales. Si el conductor
a tierra de la
residencia
es de aluminio, vet ADVERTENCIA de la seccion 5.
locales, utilizando
i
son conductores
electricos.
A. Corte el (:able neutral (blanco) del conector
Pele el (:able neutral (blanco) para exponer
del conductor.
Coloque el horno sobre una mesa o plataforma en Forma nivelada con la abertura. Para un horno _]nico,
la plataforma debe soportar 200 Ibs. (91 kg); para un horno doble, la plataforma debe soportar 375 Ibs.
(170 kg). Conecte el conducto Flexible a la caja de conexiones electrica como se indica abajo*, Posicione
el conducto de modo tal que se apoye detras de la unidad en un circulo natural cuando el horno sea
instalado _*. Tendra que comprar una abrazadera para alivio de tension apropiada para completar la
conexion del conducto a la caja de conexiones.
Caja de conexiones
S
5, Requisitos
vez se quita del gabinete o si el homo
o el reborde sufrira danos,
se quita de servicio,
el
1
|
1
del propietario
• Asegurese
de que todos
de dejar el homo.
para la lista de deteccion
los controles
del homo
y solucion
se encuentren
que las unidades
de problemas.
en OFF (apagado)
antes
correcta

advertisement

Related manuals