Aeris 750GT Owner's Manual

Add to My manuals
129 Pages

advertisement

Aeris 750GT Owner's Manual | Manualzz
 owner's guide
Distinguishea by сея
LIMITED TWO-YEAR WARRANTY
For details, refer to the Product Warranty Registration Card provided.
COPYRIGHT NOTICE ry
This owner's guide is copyrighted, all rights are reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, :
or reduced to any electronic medium or machine readable form without prior consent in writing from AERis / 2002 Design.
750GT Owner's Guide, Doc. No. 12-7041
© 2002 Design 1999
2002 Davis Street
San Leandro, Ca. USA 94577
510/569-3100
TRADEMARK NOTICE
AERIS, the AERIS logo, 750GT, and the 750GT logo are all registered and unregistered trademarks of Aeris. All rights are reserved.
PATENT NOTICE
U.S. Patents have been issued, or applied for, to protect the following design features: Pod
Dive Time Remaining (U.S. Patent no. 4,586,136), Data Sensing and Processing Device (U.S. Patent no. 4,882,678), Nitrogen Bar Graph
(U.S. Patent no. 4,582,657), and Ascent Rate Indicator (U.S. Patent no. 5,156,055), User Setable Display (U.S. Patent no. 5,845,235) is с ;
owned by Suunto Oy (Finland). LÀ
DECOMPRESSION MODEL 23
The programs within the 750GT simulate the absorption of nitrogen into the body by using a mathematical model. This model is merely a way 7
to apply a limited set of data to a large range of experiences. The 750GT dive computer model is based upon the latest research and experiments |
in decompression theory. Still, using the 750GT, just as using the U.S. Navy (or other) No Decompression Tables, is no gnarantet .
of avoiding decompression sickness, i.e. “the bends.” Every diver’s physiology is different, and can even vary from day to day. No
machine can predict how your body will react to a particular dive profile.
750GT
FCC ID: MHSA
FCC Compliance:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause
harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Interference Statement:
This equipment has been tested and found to comply with the limits for an Intentional Radiator, a Class B Digital Device, pursuant to
Part 15 of FCC Rules, Title 47 of the Code of Federal Regulations. These limits are designed to provide reasonable protection against
harmful interference in a commercial or residential installation. This equipment generates, uses, and can radiate radio frequency energy,
and if not installed and used in accordance with the instructions, may cause interference to radio communications.
There is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or
television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interfer-
ence by one or more of the following measures:
a. Reorient or relocate the receiving antenna.
b. Increase the separation between the equipment and the affected receiver.
c. Connect the equipment and the affected receiver to power outlets on separate circuits.
d. Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications not expressly approved by AERIS could void the user's authority to operate
the equipment.
CONTENTS
FEATURES AND DISPLAYS ...... paonenoanennno eupanobronoooeooatocavanearorveneceneneaaee
Introduction ........... | : sancescenmaae es roecianeconeerav anne near nene eneeeenea penneapanenaas
Control Buttons ........... prenaannan vanes ererononacarcactorbataconeaonan penenmeneneaceneceen avena enacactcaeca aca nracapnacanenena 4
Informational Displays .............—m—r.w...e.eeveeezons parereacione
Bar Graphs ems. crrnsasasac sense meurs
Nitrogen Bar Graph .............—.—.... peoonoaneneneree ccoo nenpnoaca rear reanecacenerenanorenantonccraeeceoe
Oxygen Accumulation Bar Graph... crsssasasenss
Ascent Rate Indicator .................. prnnconnnano ... prapeeceseme are re arae rar eran creme ces 8
Breathing Gas Consumption Indicator ennaceniooo ataron nena ieee rears rree sree sear areata nner ean re tren nrannnnans .... 9
Breathing Gas Time Remaining Bar Graph .................eee nee ee IDR DT IND A 10
Dive Time Remaining.... eomneooncoaveecoaaoevarrovnae eo rta neeonocacrtaoriecee enn cenearatoconrecanancarenos LO
Breathing Gas Time Remaining penacaroorenmarcemee. Preenoaorreananenarea ena nareneeacatereeecaneneeeeens 11
No Decompression Dive Time Remaining ...... Grarsssseurs reearenarecara conan eeneana „ее 13
Oxygen Accumulation Time Remaining ................. parvencenerenarrenenaneane DE!
Alpha Numeric Display Seesen ER er De cveverseue verres 14
Cylinder Pressure Display ..….……reiseoncearmmeeenenmnnsennmenn£nnnnnnnnnnnnnnnn peventanoananenananrenconos 14
Depth Displays .. .. ee eannoraocacacreaaceneea
Time Displays ...........e.......m.. pucenooonasranenena
Ambient Temperature Display
Audible Alarm... eens érsnarécensceereneneneemanaensenennengreanes era ere sceau ne noancenmecane ae nenesaan rene 17
Warning Message essen anne raveconrennaa tana ne neon nen anonnenanecenarentarenacareococananeracanecareracrrcecaa 19
Backlight Feature ....
=. +. = " ана т ани +
$ ERFEREFEFENEE EFE E ны PEA OA 15
чт ниве рн ни не ан EEE FFAA A 16
тина кн ELE REE REE EE Ee EE EE EE EEE EE EES EE EL EL ES RE EEE EERIE ERY ENE ERE EEE ET EEN NEE EN PE 19
7150GT
an mn a
CONTENTS (continued)
Operating Temperature ............ VV EE OPC o 20
Sharing the 750GT ...............wee=eereeceeccncee e RD DIRIIR O TRIO IDO O RD De eee ee 21
LCD Key ……….…...……ssserseces ESS VE PSE ER ESS EEE EEE em mee . 22
ACTIVATION AND SETUP rrr в oo 23
Making the 750GT Personal ........ yr eT CU URN 0. BA
Activating the Display .................. prcecerenanenrraneeom. ne... DO 25
Surface Mode ...... неее. empero - peoneanvenaeoconra DO
Mode Menu SySt@m …..…..….…sccriseseesceresceeenearensesencenereransenrencanvenee ER a, 29
Entering Settings ................. sraneesesseensensepennesarun0es ve SA e 30
Set Time ......... a ne... e .. 31
Set Date essen nnn a aaa ... EN .32
Set Alternate Display ............. VS CO EV SOV НЕЕ 33
Set Units of Measure. .................. . .. En!
Breathing Gas and Depth Alarm Settings penecenas A 35
Depth Alarm Setting ..............e.........eme.. EE EEE EESHER 35
Breathing Gas Alarm Setting nano. sxanansssas en en sasen ee sssee0s ‚ 36
Set Depth, Breathing Gas, and Audible Alarms . EEE 37
Linking Procedure ..................renvemeere DD EEE ‚ 38
Set Language ......... a ES SSR SOUR ES EVE 41
Language Correction Procedure …………………….….……. A pracraransansanees sans ensenenman aan ses ‚42
CONTENTS (continued)
PREDIVE AND DIVE MODES .. panaancanaaenenene 43
Positioning of the Display Module ….…....…...….………eceecrernrennntntnnnnennnnnnnnnennnnnnnn*nnnnnns 45
Link Interruption UndErWAtET ….……reererenannennnnnnenennsnennnnnnnnnannnnnnnnnnnnnnnnbnnenen 4.0... 45
Operational Modes..................e.....e. penoanonenonenensarenerenereonecaceceacerecae naar even 46
FOZ Mode ....................e.neiiecicaeoonernenne ro re neeranooorreeeracee. N
FOZ Set for Air … prescrperasenes ve O Y
Settings FO2 for a Nitrox Dive ...., prarsensresremrasre me recacaa acces prsveroonvoroncoencenarooenenru stan eeanenreecónos O
Plan Mode ............—.e-.e.e.enenene rene nen eDA Garspesenee rss sen sentence ns nareroceracaroacacranacaneaarneee 49
No Decompression Dive Mode …….………..….…….…erecseree poninoraoacorrereoeneninerceNoeareaoecertaranran ee enmas e... 53
Decompression Dive Mode ...............ree=.er essere RR RR ROI RR Dee nenita neon na nenens 54
Violation Modes ser rer mesi e VERKARREKKAKAKAERRRRERERRKARKELKEEREUEKARBEATERKRERUUREUUEHG 20... DO
Gauge Mode .............emmmeescccececioreciceceococereca mean carr ne nececeorr avantavanceneeceveravererusvenanana nana sac prsaanens es DO
Ascending to the Surface ...............e.e.... er einer reee e Re e reee... DO
АН а Di 1 7
1611 e ving LRA RETR E RENE LR EEE REESE RRELEERS IRENE STER ESSN TRERY) été kdb bbb ra rad Pr Fr rr br AP Pra FF FEAF FEI EAR FE EAT HN IA RA FFAS FFARR RF Fra RR 5
POST DIVE MODES ......es==mmesvaco eeDurmanvenze runcenarao 39
Post Dive Surface Mode ................ee.eeeeerecereenrnte en aerea near tner reee ennene nn reraane ee. 60
Transition Period..................... ercer peninvanonenena N
КОЗ Моде... perinoonoooreenane rene ene nancar ea eerareen ones pneenannaano nano naana one recpenenen acarreo es 61
Plan Mode .............. pessasasensnen senc asen crane anus venassaneenvanpanpanen sens rrenranrennrcen re 62
Time to Fly......... prrconnoonecone nano errar enamore perrnaneenca ves сене. 68
Dive Log Mode ................m2...... pecinrnnararanonecea oo norenennnenananecea souvesoneansensas cas oncresressssrerercenmanesrnne nes O4
History Mode ...........m........ prasasnres Grsatressrn care rerennan rene eee ec ne ssrrperiasenteenense re raser nee rene a cancer rennes OT
External Access MOC®@.......….....rreersserenrarantancanenaranarsansnrsenareran serres nacsecansas sance nes crunen se OS
750GT
CONTENTS (continued)
HANDLING THE EXTREMES sos... ...... 69
Emergency Decompression aaa aaa Tae aan e. AA ra 70
Gas Time Remaining During Decompression .. nconeeranenrenoene remates .72
Caution Zone (Nitrogen Bar Graph) ..............—.=e-resmenserarciórectan nea rene n enero neon caera caceres 19
Decompression Dive Mode ......... .. cerenoeenecenenentaor nace oeae neon rtacentonee near ncecrnane 14
Violation Modes ................-.e.emensecacanenarneane retar cene secre cerar race reeea .. .. 76
Conditional Violation Mode ...............—....+==eeerercacconee ene prscapeesemssa encre uersre mascara ST 76
Delayed Violation Mode ...................e.erereascocooieeeaos prcurinerennotonacenacenaareancecee UN
Immediate Violation Mode ...............—.r.e.+=mmmvesenen.. ee 79
(Gauge Mode ......... a DA A 80
Permanent Violation ......... a ННЕЕя EEE mo O1
Exceeding Maximum Operating Depth NN ONES LAO CA 81
Oxygen Exposure... ve >
Partial Pressure of Oxygen + a
High PO2 Dive Mode ..................w...mececarernannnenonos
Oxygen Accumulation ........ pecenenenenanee. Uy a rrr CT re 84
FCO ry CTL TTYL LT Ly Vm 85
Warning Messages ESS
Unexpected Loss of Dee lio Cee EE EEC Ee oe Ae .... 97
CONTENTS (continued)
CARE AND MAINTENANCE covernseavarnan g....... sancossernen caen 89
Care and Cleaning esse peaseaneanere nee ceness eenananonecaanenoeaonntecerenTa „неее. В9
Annual Inspections and Service NH
How to Obtain Service ......... paneacaonoeonenaneaooena reo nennanan acre penorarenrrnacocaoreracoornaer reeeoe rear ena 92
Battery Life cone TURTON preenennnna 93
Low Battery Condition ...............—..=e. reee aer e ere ID TT TRE A
Battery Replacement iinet .. en 06
Flooded Battery Compartment ................. perooroneceooeenerevnanencenimacaotencensoecrorrecamaancaneranarrancereoes DO
Transmitter Instaliation Instructions .. ER AREA EEG : неее 99
Transmitter Compatibility with Nitrox aan rer penononeccareneoconarcarenenorneccoaeecarrereas 100
REFERENCE .......... enennanecono eeconoenanenenTenvecranrenenre enanmentas 101
More About Flying After Diving... rooreceocaioarocannaneoaa re rooacauean ere reacaa Teno nactrroraroaaceaaenenen cane ncenerenea 102
More About Altitude Diving..........ew...em....... perrnaranereenencrarenee. prumivioreoerecaoenrcer 103
More About Nitrox Diving ..............e_.eonececes perrasreeracssacauvennencees O Y
Multiple Tissue Tracking as perenaneceoonno preecenerereceonerarentaracanereccenererneraos AUD
No Decompression Limits ...................ermeesmacreres pennanenos provecacieneerartoaaerreranoracrecenees … 108
Repetitive Decompression Diving.......... Peoinerooaortooneereaeeraaran aran ee terarear orar terre remareararuneen „еее. 108
Specifications ................. . pnnceroaronenaracaneaceaeeona irene DE
Responsible Computer Diving panrentnnornananacenere nano encarerearenaerararaeanananneraarenenaa ener venennaracenracrmaraare 113
Language Cross Reference .................. ненененннееееененеенененнннененннененннннннненнннненнннненнннннннннныые. „еее 114
Glossary ........ pinooocareoenioneneooneoniontaneanennanaararcorea torero enerceerantnaaracenranetnavanaraoraaraneaar avena arere nacen ceneoa 117
750GT Service Record ........e.—..... preneononooeoeaacane terna enarTaens ves E Y
750GT
X
750GI
e
A =7705
INTRODUCTION
Welcome to AERIS and thank you for choosing the 750GT!
Your new 750GT is a two component, hoseless, integrated system that consists
of a computer Display Module and a radio frequency Transmitter that will be
installed into a high pressure port of your regulator first stage.
The Transmitter sends tank pressure data to the Display Module via a low fre-
quency signal. In addition to nitrogen and oxygen loading data, breathing gas
consumption is calculated and displayed in graphic and alpha/numerical for-
mats on the Display Module's screen.
The Display Module can also be used without the Transmitter as a stand alone,
non-integrated computer, and will retain full use of all functions except those
related to tank pressure.
Your 750GT presents the information that you need before, during, and after
your air (or nitrox) dives using an intuitive combination of easy to read dis-
plays and unique identification icons. Tissue loading of nitrogen, accumulation
of oxygen, ascent rate, breathing gas consumption rate, and breathing gas time
remaining are presented as segmented bar graphs beside color coded reference
indicators that bring quick focus to these important status displays.
As you progress through this instructional guide, you will become familiar
with all of the unique functions and features available and see examples of the
displays that you could expect to see in the various operational modes. Refer
to the Glossary of terms in the back of this manual, and keep the waterproof
Review Card handy during your dive trips. Although it will require an initial
investment of time to become acquainted with the various icons and bar
graphs, you’ll soon agree that the 750GT is easy to understand and use.
Remember that the rules you learned in your basic scuba certification course
still apply to the diving you will do while using a dive computer - some will be-
come even more important. Technology is no substitute for common sense,
and a dive computer only provides the person using it with data, not the
knowledge to use it.
#% NOTE: Throughout this owner's guide reference is made to the
== term ‘breathing gas. The rational being that the 750GT can be
used for ‘air’ dives or nitrox’ dives. For clarity these terms are
defined as -
Breathing Gas - the gaseous mixture breathed during a dive.
Air - a breathing gas that contains approximately 21% oxygen and 79%
nitrogen (nature's common nitrogen-oxygen mixture).
Nitrox - a nitrogen-oxygen breathing gas that contains a higher fraction
of oxygen (22 to 50%) than air.
750GT
Bea-
RESPONSIBLE DIVER
at all times.
CONTROL BUTTONS
The 750GT is a unique dive computer with interactive controls that allow you
to select various display options and access specific information when you
choose to see it. The Advance (Left) and Select (Right) control buttons (Fig.
1) can be pressed repeatedly, or held in to scroll as you define settings or access
different display modes.
On the surface, before diving, you can perform the following operations using
the buttons:
» Activate the Display Module
* Select units of measure - English or Metric
* Select language for messages - English, Italian, German, Spanish, or
French
* Set depth alarm
* Set gas pressure alarm
* Turn the audible alarm - on or off
* Turn the Alternate Dive Mode display - on or off
Advance Select * Set the current date and time
* Set the display module/transmitter link code
EEE AL. Eee пои IE RE
Fig. 1 - Control Buttons
750GT
While on the surface, you can access the following Modes with the buttons:
* FO2 mode - to program the percentage of oxygen in the nitrox mix.
* Plan mode - to view no decompression limits and plan your next dive.
* Log mode - to view data from your 12 most recent dives.
* History mode - to view the total number of dives, maximum depth, etc.
* Set mode - to establish preferred selections.
* External Access mode - to download (copy) dive data from the 750GT to
a PC log/profile program.
During Dive modes, the Advance (Left) button can be used to activate the
display's backlight, and the Select (Right) button can be used to access an Al-
ternate Dive mode that displays additional information including maximum
depth, dive time and temperature.
INFORMATIONAL DISPLAYS
Operational modes and status information is visually represented numerically
and/or graphically and can be understood at a glance with the aide of Universal
Icons (Fig. 2) that identify and bring quick focus to the displays. Also, segmented
bar graphs will show how close you are to critical limits. Refer to the LCD Keyon
page 22 for identification of icons, symbols and bar graphs.
Fig. 2 - Universal Icons
emi
E
rT — EE
тт, Te
a A
Ra fe
HE
i i
e
0A
730 E Fin
Fig. 4 - Bar Graphs
Each numeric and graphic display represents a unique piece of infor-
mation, It is imperative that you understand the formats, ranges,
and values of the information represented to avoid any possible mis-
understanding that could result in error.
In critical situations, urgent messages appear in the lower screen and an au-
dible alarm sounds to alert you to check this information. These concise,
simple messages (Fig. 3), such as “TOO FAST” or “TOO DEEP" are displayed
in the language that you choose during setup.
BAR GRAPHS
Five segmented bar graphs appear around the perimeter of the upper screen
(Fig. 4). The green, yellow, and red color coded portions of the peripheral de-
cal denote normal, caution, and danger zones, respectively. When underwater,
you can quickly focus on the bar graphs to make sure that they are in the
green. You can quickly verify that you're not getting too close to the no de-
compression limit or the oxygen tolerance limit, or ascending too fast, or con-
suming breathing gas too fast, or running low on breathing gas.
Nitrogen Bar Graph
The Nitrogen Bar Graph represents nitrogen loading, showing your relative no =
decompression or decompression status. As your depth and elapsed dive time
increase, segments will add to the graph beginning in the lower left portion of
the screen. As you ascend to shallower depths, this bar graph will begin to re-
cede, indicating that additional no decompression time is allowed for multilevel
diving.
The Nitrogen Bar Graph (Fig. 5) monitors 12 different nitrogen compartments
simultaneously and displays the one that is in control of your dive. It is di-
vided into a green No Decompression zone, a yellow Caution zone, and a red
Decompression zone. The yellow Caution Zone (Fig. 5a) provides a visual rep-
resentation of how close you are to the no decompression limit, allowing you
to make a decision regarding safety stop duration or necessity. While you can-
not provide a guarantee against the occurrence of decompression sickness, you
may choose your own personal zone of caution based upon age, physique, ex-
cessive weight, etc., to reduce the statistical risk.
The Nitrogen Bar Graph assists you with managing decompression by filling a
large red ceiling stop required’ segment (Fig. 5b).
71% WARNING: AERIS advocates responsible diving practices con-
li sistent with your individual level of formal training and experi-
ence, and does not recommend decompression diving or diving
below 130 feet (39 m).
750GT
Te o
PLE
Fig. 5 - Nitrogen
Bar Graph
Oxygen Accumulation (02) Bar Graph
#% NOTE: Displays associated with oxygen and the O2 bar graph
= will only appear if FO2 has been set at a value other than 'Air'.
The Oxygen Accumulation (02) Bar Graph (Fig. 6a) represents oxygen load-
ing, your relative oxygen tolerance dosage (OTU), showing the maximum of
either per dive allowable oxygen, or 24 hour period allowable oxygen. As your
exposure (accumulation of oxygen) increases during the dive, segments will
add to the graph around the upper right perimeter of the screen. As accumu-
lation decreases, the bar graph will begin to recede, indicating that additional
exposure (accumulation) is allowed for that dive, and that 24 hour period.
gen (PO?) by flashing the large red Danger zone segment as a warning when
the level of PO2 exceeds the maximum allowed limit of 1.60 ATA . This is ex-
plained in detail in the Handling the Extremes section.
Ascent Rate Indicator
The Ascent Rate Indicator (Fig. 6b) is provided to help you avoid excessive as-
cent rates by providing a visual representation of ascent speed, rather than
Fig. 6 - 02 Bar Graph & just showing that you are ascending too fast.
Ascent Rate Indicator
The 02 Bar Graph also assists you with managing high partial pressure of oxy- .
The 8 triangular segments of the bar graph, located beside green, yellow, and
red reference zones, appear beginning from the bottom and may be considered
an ascent rate speedometer. Green is a ‘normal’ rate, yellow is a ‘caution’ rate,
and red is "Too Fast’. The actual speeds that the segments represent are
shown at the left.
When your ascent rate exceeds the maximum recommended rate of 60 feet (18
meters) per minute, the bar graph segments will enter the red zone and all dis-
played segments will flash once per second until your ascent speed is slowed.
When this occurs, you should immediately slow your ascent.
The Ascent Rate Indicator has been granted U.S. Patent No. 5,156,055.
Breathing Gas Consumption Indicator
The Breathing Gas Consumption Indicator bar graph (Fig. 7) is a true biofeed-
back monitor that indicates your current breathing rate as compared to your
personally established breathing parameters. The comparison is based upon
an average rate established during the first 70 seconds of breathing that is
sensed.
After the comparison, the bar graph will provide you with continuous visual
indication of your breathing rate as it slows or increases.
750GT
Segments = Ascent Speed
QG = 0 - 10 fpm (0-3 mpm)
= 11-20 fpm (3 - 6 mpm)
2 = 21 - 30 fom (6 - 9 mpm)
à = 31 - 40 fom (9 - 12 mpm)
4 = 41-50 fpm (12 - 15 mpm)
О = 51 - 60 fpm (15 - 18 mpm)
6 = 61 - 90 fpm (18 - 27 mpm)
7 = 91 - 120 fpm (27 - 36 mpm)
8= >120 fpm (>36 mpm)
(when > 5, the segments flash)
Fig. 7 - Breathing Gas
Consumption Indicator
9
Breathing Gas Time Remaining Bar Graph
The Breathing Gas Time Remaining Bar Graph (Fig. 8) provides a graphic rep-
resentation of the time that you can remain at your present depth and then,
following a safe ascent, surface with a predetermined breathing gas reserve,
This calculation and display is based on your breathing gas consumption rate
that is continually monitored, and it takes into account the breathing gas re-
quired for a safe ascent including any required decompression stops.
The green, yellow, and red zones adjacent to the bar graph enable you to
quickly focus on remaining breathing gas times of 60 minutes or less, based on
your pre selected Gas Alarm Set Point. The bar graph is more precise as time
remaining decreases toward the red zone.
DIVE TIME REMAINING
One of the most important pieces of information on the 750GT is the patented
Dive Time Remaining numeric display. To numerically display Dive Time Re-
maining, the 780GT constantly monitors three critical pieces of information;
no decompression status, oxygen accumulation status, and rate of breathing
gas consumption. The Dive Time Remaining display will indicate the time
that is more critical for you at that particular moment (i.e.; whichever time 1s
Fig. 8 - Breathing Gas Time the least amount available of the three).
Remaining Bar Graph
10
The time being displayed is identified by the No Decompression Dive Time ee Ads
icon, or Gas Time Remaining icon displayed to the left of the numeric display, \ a м
or the O2 symbol displayed to the right of the numeric display (Fig. 9). (No Decompression Time)
Knowing that you have 45 minutes of no decompression time remaining is not
as critical as knowing that you only have 40 minutes of breathing gas time re-
maining. Or, knowing that you have 40 minutes of breathing gas time remain- er A
ing is not as critical as knowing that you only have 35 minutes of oxygen accu- sa ba
mulation time remaining. The 750GT presents the dive time remaining that is (Oxvgen Accumulation Time)
considered to be of primary importance. This unique feature has been granted _ |
U.S. Patent No. 4,586,136. Fig. 9 - Dive Time Remaining
Breathing Gas Time Remaining
Breathing Gas Time Remaining will appear as the numeric Dive Time Remain-
ing display (Fig. 10a) only when it is less than N 0 Decompression Time Re-
maining and Oxygen Accumulation Time Remaining. Breathing Gas Time Re-
maining of 60 minutes, or less, will be displayed continuously as the Gas Time
Remaining Bar Graph (Fig. 10b) regardless of which time is being displayed as
the numeric Dive Time Remaining. The bar graph represents only Breathing
Gas Time information and it will be the only indication of breathing gas time
remaining if you are in a decompression or violation mode,
Fig. 10 - Breathing Gas
Time Remaining
11
A =77053:
12
The 750GT calculates Breathing Gas Time Remaining using a patented algo-
rithm that is based on a diver's individual breathing gas consumption rate and
depth. Tank pressure is measured once each second, and an average rate of
consumption 1s calculated over a 90 second period, This rate of consumption is -
then used in conjunction with a knowledge of the depth dependence to predict
the breathing gas required for a safe ascent including any required decompres-
sion stops.
Breathing gas consumption and depth are continuously monitored, and
Breathing Gas Time Remaining reflects any change in your circumstances.
For example, when a buddy starts breathing from your octopus or you sud-
denly find yourself swimming against a strong current and begin breathing
more rapidly, the 750GT will recognize this change and adjust your Breathing
Gas Time Remaining accordingly.
Remember, the Breathing Gas Time Remaining is the time you can remain at
the present depth and still surface with the tank pressure reserve (Gas Alarm
Set Point) that you set during setup. When Gas Time Remaining indicates
zero, you should immediately initiate a controlled ascent. However, thereisno
reason to panic, the 750GT has allowed for the breathing gas necessary for a
safe ascent including any emergency decompression stops.
750GT
No Decompression Dive Time Remaining
No Decompression Dive Time Remaining is the maximum amount of time that
you can stay at your present depth before entering a decompression situation.
It is calculated based on the amount of nitrogen absorbed by twelve hypotheti-
cal tissue compartments. The rates each of these compartments absorb and
release nitrogen is mathematically modeled and compared against a maximum
allowable nitrogen level. Whichever one of the twelve is closest to this maxi-
mum level is the controlling compartment for that depth. Its resulting value
will be displayed numerically (Fig. 11a) along with the No Decompression Dive
icon and graphically as the N itrogen Bar Graph (Fig. 11b).
Âs you ascend from depth following a dive that has approached the no decom-
pression limit, the Nitrogen Bar Graph will diminish as control shifts to slower
compartments. This is a feature of the decompression model that is the basis
for multilevel diving, one of the most important advantages the 750GT offers.
See the Reference section for more information pertaining to tissue tracking.
The no decompression algorithm is based upon Haldane’s theory using maxi-
mum allowable nitrogen levels developed by Merrill Spencer. Repetitive diving
control is based upon experiments designed and conducted by Dr. Ray Rogers
and Dr. Michael Powell in 1987. Diving Science and Technology? (DSAT), a
corporate affiliate of PADI*, commissioned these experiments and now uses Fig. 11 - No Decompression
the findings in the Recreational Dive Planner" distributed by PADI Dive Time Remaining
13
a A A UI aia
Fig. 12 - Oxygen Accumula-
tion Time Remaining
Fig. 13 - Cylinder Pressure
14
Oxygen Accumulation Time Remaining
Oxygen accumulation (exposure) during a dive, or 24 hour period, appears
graphically as the O2 Bar Graph. As time remaining before reaching the oxy-
gen exposure limit decreases, segments are added to the O2 bar graph. When
the amount of time remaining before reaching the oxygen limit becomes less
than the No Decompression Dive Time Remaining or Breathing Gas Time Re-
maining, calculations for the dive will be controlled by oxygen. Oxygen Time
Remaining will then appear as the main numeric time display (Fig. 12a) as sig-
nified by the O, symbol appearing to the right of the display.
As oxygen accumulation continues to increase, the O2 bar graph will enter the
yellow Caution Zone. High O2 Mode is explained in detail in the Handling the
Extremes section.
ALPHA/NUMERIC DISPLAYS
Cylinder Pressure Display
The Cylinder Pressure display (Fig. 13a) indicates how much breathing gas is
in your cylinder, up to 5000 PSI (352 BAR) to nearest 10 PSI (.5 BAR). The
value of pressure will be displayed during all dive modes when the Display
Module is linked to the Transmitter and within the operating range. Linking
is explained in more detail in the Pre Dive and Dive Mode section.
Depth Displays
NI TTT rT feb Tre macia
e A EE EEE
Par RASE EE rt SEE A
i cna yy BoA
Ts
GE
During a dive, the Current Depth display (Fig. 14a) indicates depths from 0
to 330 feet (99.5 meters) in 1 foot (.5 meter) increments,
The value of Current Depth will be displayed during all dive modes unless you
descend deeper than 330 feet (99.5 meters), at which point the display will
show three dashes ( - - - ) to indicate that you have gone 'out of range’. This is
described in detail in the Handling the Extremes section.
A second depth display (Fig. 14h) indicates the Maximum Depth reached
during that dive. If the Alternate Mode is turned ‘off, the display will appear
when the Select/Right button is pressed. More critical information such as a
message will override it,
In the event that you descend deeper than 330 feet (99.5 meters), this display
will only show three dashes ( - - - ) as the Maximum Depth for the remainder
of that dive, and as the Max Depth in the Dive Log for that dive. This is de-
scribed in detail in the Handling the Extremes section.
During a Decompression Dive, the required Ceiling Stop Depth appears
(Fig. 15a). The display toggles with the message CEILING once every 15 sec-
onds. This is described in detail in the Handling the Extremes section.
pred
16
Fig. 17 - Time Displays
(Alternate Mode On)
Time Displays
The Main Time display (Fig. 16a) has larger digits than the other numerical
displays. Depending on the operating mode that the 750GT is in at the time,
the display indicates Elapsed Surface Time, theoretical Dive Time Available,
Dive Time Remaining, or Total Ascent Time required.
A second Time display indicates Elapsed Dive Time, Decompression Stop
Time required, Time of Day (Fig. 16b), or Time to Fly.
Each display is described in detail in subsequent sections of this owner's guide.
Most of the time displays are shown in hour:minute format (ie. 1:02 repre-
sents one hour and two minutes, not 102 minutes!). The colon that separates
hours and minutes blinks once per second when the display is indicating real
time such as elapsed Surface Time. Dive Time Available, No Decompression
Dive Time Remaining, Total Ascent Time required, or Time to Fly are calcu-
lated projections of time and use a solid (non-blinking) colon to indicate that
they are counting down, rather than counting up.
Elapsed Dive Time (Fig. 17a) appears when the Alternate Mode is turned ON
(described on page 33). If the Alternate Mode is turned OFF, Elapsed Dive
Time can be displayed during a dive by depressing the Select/Right button.
Ambient Temperature Display
When the Alternate Mode is turned ON , ambient Temperature is displayed
continuously during a dive (Fig. 18a). If the Alternate Mode has been turned
OFF, Temperature can be displayed by depressing the Select/Right button.
#4 NOTE: More critical information such as Ceiling Stop Depth
= required or a Message will override the display.
AUDIBLE ALARM
When the Audible feature is set ON (described on page 38), the 750GT alerts
you to check the Message, bar graphs, and numeric displays when you are ap-
proaching dangerous situations. There are four Audible Alarms,
Potential Danger -- One Double Deep
During situations that may pose potential danger, one Double Beep is emitted
from the 750GT. These situations include:
* Entry into decompression.
* Breathing Gas Dive Time Remaining decreasing to 5 minutes.
* Partial pressure of oxygen (PO2) equal to or greater than 1.40 ATA.
(Potential Danger)
17
Immediate Danger - continuous One Beep per Second
When the 750GT senses immediate danger to you, it emits One Beep per Sec-
ond until the situation is corrected. These situations include:
E * Descending deeper than the Depth Alarm Setting.
se = * Continuous interruption of signal link of more than 60 seconds.
& Fin ° Ascending to a depth shallower than a required stop depth.
E * Ascent rate that exceeds 60 ft./min (18 m/min).
* Gas Time Remaining equals required Decompression time.
(Immediate Danger) * Gas Time Remaining equals zero (0:00).
* Partial pressure of oxygen (PO2) equal to or greater than 1.60 ATA,
* Oxygen accumulation greater than the allowed per dive or 24 hour limit.
Permanent Violations — Single Long Beep
If you enter a Delayed or Immediate Violation Mode, a Single Long Beep will |
be emitted. This will occur if one of these Violation rules are broken:
BES * Depth is shallower than the required stop depth for more than 5 minutes.
* Required Decompression exceeds a 60 FT/ 18 M ceiling.
©
(Violation)
18
750GT
Transition — Short Веер
To indicate that a command has been accepted, the 750GT will emit a Short
Beep whenever you use the control buttons, and immediately following activa-
tion and the Diagnostic Mode.
WARNING MESSAGES
(Transition)
The Message display (Fig. 19) provides a visual explanation of what is occur-
ring when the Audible Alarm sounds, working in conjunction with the Depth
and Gas Alarm Set Points, as well as Decompression and Violation Modes, and
the Ascent Rate Indicator. Messages, such as TOO FAST, TOO DEEP, GAS
ALARM, and VIOLATION, flash on the display in the language that you set.
This is described in detail in the Handling the Extremes section. A language
cross reference is provided in the back of this manual for your convenience.
BACKLIGHT FEATURE .
In addition to using a high contrast LCD for easy readability in low light condi- | OSESEGSAS
tions, the 750GT backlight feature evenly and easily illuminates the full dis- | dems EL
play. On night dives, in caves, or during any other low light situation, you can
illuminate the display when you wish to with the touch of a button. Fig. 19 - Warning Messages
19
Fig. 20 - Backlight
140°F (60°C)
Tac prat a ea
00°
20 10-
Fig. 21 - Operating
Temperature Range
20
Upon activation the backlight will illuminate the display while the unit per-
forms its diagnostic check. To activate the backlight during the Dive mode,
simply press the Advance/Left control button (Fig. 20). The backlight will re-
main illuminated as long as the button is depressed, plus 10 seconds after be-
ing released (for a maximum of 15 seconds).
AERIS recommends that you always carry primary and backup dive
lights when conducting dives that could include low light situations.
OPERATING TEMPERATURE
The 750GT will operate in almost any temperature diving environment in the
world (Fig. 21) between 32 and 140°F (0 and 60°C). At extremely low tempera-
tures, the LCD may become sluggish, but this will not affect it's accuracy. If = |
stored or transported in extremely low temperature areas (below freezing), you
should warm the module and its batteries with body heat before diving. ==“
Even though the 750GT will operate in this wide range of temperatures, it is
possible to damage the electronics if left exposed to direct sunlight,
or in a hot confined space (like a car trunk). After the dive, cover the o
Display Module and keep it out of the sun. If inadvertently left in the direct
sunlight for a long period, the LCD display may become totally black. If this ©.
occurs, immediately immerse the Display Module in water. The display should | |
recover its normal appearance after a few minutes.
750GT
# % NOTE: Damage from excess heat, or cold, is not covered by the
&— 750GT two year limited warranty.
SHARING THE 750GT
dí WARNING: Never participate in sharing or swapping of a dive
CA computer. Doing so may result in injury or death.
The 750GT provides information based upon a diver's personal dive profile,
and therefore must not be “shared” between divers. You should never,
under any circumstances, swap your computer with another unit between
dives, or share your computer with another diver underwater.
It is impossible for two divers to stay precisely together underwater, and your
computer's dive profile tracking of previous dives will be pertinent to
you only. Nitrogen and oxygen loading of a second user may be significantly
different and thus swapping dive computers could lead to inaccurate and po-
tentially dangerous predictions of decompression and oxygen accumulation sta-
tus. This rule applies to the use of all dive computers, but is especially impor-
tant when using the 750GT, due to the personal information it provides.
Be a -
RESPONSIBLE DIVER
at all times.
21
a- Gas Consumption Indicator
b- Nitrogen Bar Graph
e- O3 Bar Graph
d- Ascent Rate Indicator
e- Gas Time Remaining Bar Graph
f- Operating mode icon (detail A) .
g- Log mode icon
h- Oxygen mode symbol
i- Low Battery icon (detail B)
j- Maximum Depth icon
k- Elapsed Dive Time icon
1- Temperature icon
m- Transmitter Link icon
n- PC Interface sensors
DETAIL À: À J
(5
синь Титов LS Fa
Firdepançrensten Tr Arana | Desert Sa Tre
AE e E
e We
E
EA
DETAL. E:
Rasines
Fig. 22 - LCD Key
E) Ч
22
750GI
a
Fig. 23 - Positioning of
Transmitter/First Stage
24
MAKING THE 750GT PERSONAL
Before you dive with the 750GT for the first time, you will need to become ac-
quainted with its interactive features, and select your personal display settings =~
using the Control Buttons and Mode Menu.
The Transmitter must first be installed into a high pressure port of your regu-
lator first stage, facing to one side (Fig. 23). AERIS strongly recommends that
installation be performed by an Authorized AERIS Dealer at the time of pur-
chase. Instructions for this procedure are provided on page 99.
#% NOTE: The 750GT transmitter is compatible with most first
E stages, but cannot be guaranteed to fit certain models. Check
with your Authorized AERIS Dealer to verify compatibility with =
your regulator first stage.
For the Display Module to receive a tank pressure signal from the Transmit-
ter, the two devices must first be 'Linked'. The serial number of the Transmit- '
ter must be entered as the 'Link' code in the Display Module. If the Display
Module and Transmitter were packaged and shipped from the factory asa
complete system, the code of the Transmitter has already been entered as the
Link’ code in the Display Module.
rr ye a ES
e
750GT
If the two units have been purchased separately by you or your Authorized
AERIS Dealer, it will be necessary to set the Link code in the Display Module
so that a tank pressure signal can be received. If the Display Module has been
purchased as a stand alone computer without the Transmitter, it has been pre-
set at the factory as a non-linked unit, but can easily be reset at any time to
Link’ with a Transmitter code (serial number) using the Control Buttons.
SET:LINK is described on page 39.
ACTIVATING THE DISPLAY
Before activating the Display Module, the regulator containing the Transmit-
ter must be connected to a full tank and pressurized by slowly opening the
tank valve. Tank pressure of 50 psi (3.5 BAR ), or greater, is required for the
Transmitter to activate. Position the Display Module within 3 feet (1 meter)
of, and parallel to, the Transmitter (Fig. 24) and hold it in this location during
activation.
ТА, WARNING: Never activate the 730GT underwater. This may
ED result in inaccurate depth and no-decompression time displays.
H activated deeper than 4 feet (1 meter) underwater a message
“TOO DEEP" will appear and the unit will shut off.
Fig. 24 - Positioning
During Activation
25
To activate the Display Module
* press the Select/Right button once and release.
The 750GT will immediately enter Diagnostic Mode, displaying all “8’s”, fol-
lowed by “dashes”, and then a countdown from 9 to 0 (Fig. 25). The Message
SELF - TEST will appear and the backlight will illuminate the display
throughout the diagnostic check. A single beep will be emitted to indicate suc-
cessful completion of the operation.
While conducting diagnostics, the 750GT checks its display functions, coded
frequency link to the Transmitter, and battery voltage to ensure that every-
thing is working correctly.
Fig. 25 - Diagnostics
in Progress
If the Display Module is already set to the Transmitter's link code, the Link
icon will disappear from the screen and tank pressure will be displayed nu-
| 39 o 00- | merically (Fig. 26).
4 7 Bai :
It will also check the ambient barometric pressure, and calibrate its present
3 depth as zero. At elevations of 2,000 ft. (610 m) or higher, it will recalibrate
itself to measure depth in feet of fresh water' instead of feet of sea water.
Fig. 26 - Diagnostics’
Successful
26
750GT
During the diagnostic mode, battery voltage level of both the Display Module
and the Transmitter are measured to determine if sufficient voltage is avail-
able to maintain operation for one day of diving. If there is not enough battery
voltage in the Display Module, it will deactivate itself or would not have acti-
vated at all. If there is not sufficient voltage in the Transmitter, the Link icon
and a tank pressure of "00" PSI (BAR) will flash on display (Fig. 27). This
could also indicate one of the following conditions:
* The Transmitter was not pressurized prior to activation of the Display
Module.
* The Display Module was not positioned in close proximity to the Trans-
mitter during activation, or not correctly positioned parallel to it.
* The Display Module is not linked to the same coded frequency as the
Transmitter.
In the latter case, it will be necessary to follow the prescribed linking proce-
dure outlined on page 89 to set the Display Module to the Link code that
matches that of the Transmitter's serial number, or to set a specific link code
that will allow the Display Module to function as a stand alone unit.
If the Display Module was out of the range of the Transmitter while in Surface
Mode, tank pressure reappears and the Link icon disappears within 5 seconds nn
after the Display Module is returned to its correct proximity to the Transmit- Fig. 27 - Unsuccessful Link
ter.
27
„``
28
Be a -
RESPONSIBLE DIVER
at all times.
Low Battery conditions and battery power conservation are described in more
detail in the Care and Maintenance section.
ds WARNING: If either or both of the Low Battery icons remain
22 on display following diagnostics, AERIS strongly recommends
that you DO NOT dive until the batteries are replaced. See the
battery replacement procedure on page 96.
If no dive is made within 2 hours after initial activation, the Display Module
will automatically deactivate to conserve its battery power. Check your Dis-
play Module before entering the water to verify that it is functioning and
doesn’t need reactivation.
To save its battery power while on the surface, the Display Module will stop
searching for a Transmitter signal after 10 minutes. The signal Link can be
restored by depressing the Select/Right button on the Display Module. It will
also be restored automatically upon descent on a dive.
/ft WARNING: During activation and diagnostics, if any display or
f= message varies from the information presented here, return the
750GT to your AERIS Dealer for inspection.
T50GT
SURFACE MODE
Surface Mode (Fig. 28), identified by the Surface Time icon, immediately fol-
lows Diagnostic Mode after initial activation, or after the linking procedure has
been performed. It also appears after a dive when you ascend shallower than 3
feet (1 meter). Information displayed includes Tank Pressure, Depth (00 FT),
Surface Time with flashing colon, Temperature, and Time of Day with colon
flashing.
MODE MENU SYSTEM
The Mode Menu system allows you to set the various display options that will
make the 750GT your personal computer. The Advance/Left button is used to
move through the Mode Menu and change each setting, and the Select/Right
button is used to select (enter) the mode or setting that is currently on the
screen. A brief glossary and hierarchy of the menu system is as follows:
| \30(5-
Mode - Each mode provides a different display of information, or access to a
submenu or setting, Some modes, such as Dive Mode and Surface Mode, are
entered into automatically after activation. Others, such as the FO? Mode,
Plan Mode and Alternate Dive Mode, are accessed using the Control Buttons,
when you want to view specific information. : Que
Menu - The main menu allows interactive access from the surface Mode to Fig. 28 - Surface Mode
various other modes used while on the surface.
29
ECTS EE
a
30
Settings - These are display options (settings) that are determined by you be-
fore going diving. For example, with 'alarms' you can set the depth and tank
pressure values at which you want to be alerted when you are going too deep
or running low on breathing gas.
Mode Menu Sequence Settings Sequence
* Surface * Time
s FO2 * Date
* Plan s Alternate
* Log * Unit
* History * Alarms
* Set * Link
> External Access - Language
E ¿he Mode Menu, it will automatically revert to Surface Mode.
ENTERING SETTINGS
Before going diving, enter the general settings to be used for each of your
dives. These include - Time, Date, Alternate Display, Units of Measure, Depth =:
Alarm, Gas (tank pressure) Alarm, Link code, and Language.
Fa NOTE: If the 750GT is left unattended for five minutes while in =
Fy NOTE: FO2 is a ‘pre dive' setting that must be entered prior to
5 each nitrox dive. Setting FO2 value for the breathing gas being
used is described beginning on page 46.
Set Time
Your 750GT has been factory set for 12:00 AM. To change to the current
Time, follow this procedure, beginning in Surface Mode- In _
1. Press the Advance/Left button 5 times to advance to the Set Mode.
MODE:SET will appear, with SET flashing (Fig, 29). IF you accidentally
pass the Set Mode, you will need to press the Advance/Left button repeat-
edly until MODE:SET reappears.
2. Press the Select/Right button once to select (enter) the Set Mode.
SET:TIME will appear, with TIME flashing (Fig. 30).
3. Press the Select/Right button once to select (enter) the Time setting,
Time of day will appear, with the first digit flashing (Fig. 31).
4. To set the time, press the Advance/Left button to change that digit until
it matches that of the current time, and press the Select/Right button to
save the digit shown and move on to the next.
5. Press the Advance/Left button to toggle between AM or PM, and press
the Select/Right button to save the one displayed.
Fig. 31 - Set Time of Day
31
ни”
After the time has been set, SET-DATE will appear with DATE flashing. To
set the date, continue with step 4 of the following Set Date procedure, or to re-
turn to the Surface Mode press the Advance/Left button 6 times.
set Date
Ts Ze | follow this procedure, beginning with step 1 if in Surface Mode; or beginning
is with step 4, if you just set the Time:
Fig. 32 - Set Date 1. Press the Advance/Left button 5 times to advance to the Set Mode,
2. Press the Select/Right button once to select the Set Mode.
3. Press the Advance/Left button 2 times to advance to the Date setting.
SET:DATE will appear, with DATE flashing (Fig. 32).
4. Press the Select/Right button to select the Date setting. The date will ap- ° /
pear, with the Month flashing (Fig. 33).
5. To set the Date, press the Advance/Left button to change the Month, and
press the Select/Right button to save it. Repeat for the Day and Year.
After the year has been set, SET: ALT will appear, with ALT flashing. To set
the Alternate display continue with step 4 of the following Set Alternate Dis-
play procedure, or to return to the Surface Mode press the Advance/Left but-
ton 5 times.
о JR 26 99
Teo £ уни FE Ema а A
Fig. 33 - Set Month
32
750GT
Set Alternate Dispiay
Your unit has been factory set so the values of l'emperature, Elapsed Dive
Time, and Maximum Depth will be displayed continuously during the Dive
Mode. You can turn this Alternate display OFF and have them appear only
when you depress the Select/Right button during the dive. To turn the Alter-
nate Display OFF, begin with step 1 if in the Surface Mode, or begin with step
4 if you just set the Date:
1. Press the Advance/Left button 5 times to advance to the Set Mode.
2. Press the Select/Right button once to select the Set Mode. Fig. 34 - Set Alt
3. Press the Advance/Left button 3 times to advance to the Alternate set-
ll nee
ting. SET: ALT will appear with ALT flashing (Fig. 34).
4. Press the Select/Right button to select the Alternate Display setting,
ALT: ON will appear with ON flashing (Fig. 35).
5. Press the Advance/Left button to toggle between ON and Off, and press
the Select/Right button to select the one displayed.
After the Alternate display has been set, SET:UNITS will appear with UNITS
flashing. To set the Units of Measure continue With step 4 of the following Set
Units of Measure procedure, or to return to the Surface Mode press the Ad-
vance/Left button 4 times.
Fig. 35 - Alt On/Off
33
Set Units of Measure
You can choose between Imperial (PSI and Feet) and Metric (BAR and Meters)
units of measure. Your unit has been factory set for F'T and PSL. To change to
metric units of measure, follow this procedure, beginning with step 1 if in the
Surface Mode, or beginning with step 4 if you just set the Alternate Display:
. Press the Advance/Left button 5 times to advance to the Set Mode.
. Press the Select/Right button once to select the Set Mode.
. Press the Advance/Left button 4 times to advance to the Unit setting.
SET:UNIT will appear, with UNIT flashing (Fig. 36).
4. Press the Select/Right button to select the Unit setting. PSI and FT will
appear, flashing (Fig. 37).
5. Press the Advance/Left button to toggle between Imperial and Metric
units, and press the Select/Right button to accept the one displayed.
Go D HA
After the Units have been set, SET:ALRM will appear with ALRM flashing.
To set the alarm values continue with step 4 of the Set Gas and Depth Alarm
procedure beginning on page 40, or to return to the Surface Mode press the
Advance/Left button 3 times.
Fig. 37 - Units
34
750GT
BREATHING GAS AND DEPTH ALARM SETTINGS
After planning each dive according to the no-decompression dive
times shown to be available in the Planning Sequence, AERIS
strongly recommends that you utilize one of the greatest safety fea-
tures the 750GT offers - the Gas and Depth Alarm settings.
While the 750GT uses the Audible Alarm, Messages, and Bar Graphs
to automatically alert you whenever you enter a potentially danger-
ous situation, the Alarm settings allow you to preset more conserva-
tive limits to better avoid these situations,
Depth Alarm Setting
The Depth Alarm will alert you whenever you reach or exceed the maximum
depth value that you have chosen. If you set the Depth Alarm for a depth that
is deeper than the no-decompression limits for that dive, you will first be
alerted by other built-in alarms before the Depth Alarm is activated.
When the Depth Alarm is activated by reaching or exceeding your preset maxi-
mum depth, the audible alarm will sound once per second, while the Message
TOO DEEP (Fig. 38) flashes until you ascend above the alarm value set. The
Depth Alarm value may be set for depths ranging from 30-320 feet (9-97.5 Fig. 38 - Too Deep Message
meters) in 10 foot (3 and 3.5 meter) increments, (60 FT Set Point)
35
a”
The setting that you choose for the Depth Alarm does not change the displayed
limits of no-decompression dive time remaining.
Breathing Gas Alarm Setting
The Breathing Gas Alarm is an alert that indicates you are approaching a criti- - -
cal Breathing (Gas Time Remaining. The Breathing Gas Alarm Setting refers
to the tank pressure reserve that you choose to surface with. It can be set for
tank pressures ranging from 300 to 1000 psi (21 to 70 bar).
You will recall that Breathing Gas Time Remaining is the time that you can
remain at your present depth and, following a safe ascent, still surface with a
prescribed breathing gas reserve (identified here as the Breathing Gas Alarm
Setting).
When Breathing (Gas Time Remaining reaches 5 minutes, the Gas Alarm will
emit a double beep as a preliminary warning. If your Breathing Gas Time Re-
maining decreases to zero, the tank pressure display and Message GAS
7 a / RS - ALARA - = ALARM flash (Fig. 39) until you ascend to a depth of 5 feet (1.5 meters).
o a eden TENT
While an immediate safe ascent is called for if the Breathing Gas Time Re-
maining decreases to zero, there is no reason to panic. The 750GT has allowed :
Fig. 39 - Gas Alarm for the breathing gas you will consume during a safe ascent, including decom-
pression stops if they are required, and still provide the reserve you chose.
36
Set Depth, Breathing Gas, and Audible Alarms
Your 750GT alarms have been factory set for 320 FT and 300 PSI, and the Au-
dible Alarm set for ON. These settings will be retained unless you alter them.
A, WARNING: Turning off the Audible Alarm disables an impor-
E tant tool that can help you avoid decompression diving or low
breathing gas emergencies. Although possible, AERIS does not
recommend the disablement of the Audible Alarm.
Underwater photographers may find that the alarm frightens off marine life at
a close distance, and will therefore want to turn it off temporarily before they
begin a dive involving that activity. When the Audible Alarm is turned off, the
750GT will otherwise continue to display information according to the values
that have been entered for the Alarm settings.
To set your desired Depth and Breathing Gas Alarm values. or turn the Au-
dible Alarm OFF, begin with step 1 if in the Surface Mode, or begin with step 4
if you just set Units of Measure:
1. Press the Advance/Left button 5 times to advance to the Set Mode.
2. Press the Select/Right button once to select the Set Mode.
3. Press the Advance/Left button 5 times to advance to the Alarm setting.
SE'T:ALRM will appear, with ALRM flashing (Fig. 40).
750GT
A
о SETIALPA
Pos
НН
НН
37
4. Press the Select/Right button to select the Alarm setting. The current
Depth Alarm Set Point value will appear, flashing (Fig. 41).
= 5. Press the Advance/Left button repeatedly to change the Depth Alarm Set
= Point value to the depth you choose, and press the Select/Right button to
O mae:
i era accept (save) that setting. The current Breathing Gas Alarm Set Point
7 “ALPE: E H value will appear, flashing (Fig. 42).
6. Press the Advance/Left button repeatedly to change the Breathing Gas
Alarm Set Point value to the pressure you choose, and press the Select/
Right button to save that setting. ALARM:ON will appear, with ON
flashing (Fig. 43).
7. Press the Advance/Left button to toggle between ON and OFF, and press
the Select/Right button to accent the one displayed.
After the Alarm values have been set, SET:LINK will appear with LINK flash- =
ing. To set the Transmitter Link code. continue with step 4 of the following
LINKING procedure, or to return to the Surface Mode press the Advance/Left
button 2 times.
LINKING PROCEDURE
Your 750GT Display Module has been factory set with the Transmitter's serial
number, or at serial number 999999 if no Transmitter was purchased. If the
Fig. 43 - Alarm On
38
to perform the Linking procedure.
750GT linked automatically immediately following activation, there is no need °—°
If the Link icon and pressure value of 00 PSI (00 BAR) remained flashing on
the screen after diagnostics, the Linking procedure must be performed before
the Display Module can receive tank pressure data from the Transmitter.
The linking procedure may also need to be performed in the event that your
750GT Display Module or Transmitter has received factory service, and is re-
turned to you with a different Linking code.
You may also choose to “unlink” your Display Module from the Transmitter to
use the Display Module as a stand alone computer, without its pressure inte-
grated features, or to link it to a Transmitter that has been purchased sepa-
rately at a time in the future.
To set the Display Module with the link code (serial number of the Transmit-
ter), begin with step 1 of the following procedure if in the Surface Mode, or be-
gin with step 4 if you just set the Alarms:
1. Press the Advance/Left button 5 times to advance to the Set Mode.
2. Press the Select/Right button once to select the Set Mode.
3. Press the Advance/Left button 6 times to advance to the LINK setting.
SET:LINK will appear, with LINK flashing (Fig. 44).
4. Press the Select/Right button to select the Link Mode (Fig. 45).
750GT
Fig. 44 - Set Link
Fig. 45 - Link Mode
39
EA E-7735.
40
Fig. 46 - Stand Alone
5. Compare the 6 digit serial number code shown on the display to the first
6 digits of the serial number embossed on the Transmitter.
a. If the numbers are the same, press the Select/Right button 6 times to ac-
cept (save) the code number shown. DO NOT press the Advance/Left
button, this will change the code to an incorrect number.
b. If the numbers are not the same, press the Advance/Left button to change -—
the first digit of the code as required, then press the Select/Right button
to save that digit. Repeat until all 6 digits are set correctly.
If you would like to set the Display Module to function as a stand alone, non
pressure Integrated computer, use the control buttons as described above to
set the code as 999999 (Fig. 46).
After the Link code has been set, SET: LANG will appear with LANG flashing.
To set your preferred Language continue with step 4 of the following Set Lan-
guage procedure, or to return to the Surface Mode press the Advance/Left but-
ton once.
Set Language
Warning Messages and information in the Mode Menu system are displayed in
the language that you choose - English, Italian, German, Spanish, or French.
It is very important that you do not accidentally change this setting
to a language that you do not understand.
Your unit has been factory set for English. To change the language, begin
with step 1 if in the Surface Mode, or begin with step 4 if you just set the Link
code:
1. Press the Advance/Left button 5 times to advance to the Set Mode.
2. Press the Select/Right button once to select the Set Mode.
3. Press the Advance/Left button 7 times to advance to the Language set-
ting. SET:LANG will appear, with LANG flashing (Fig, 47).
4. Press the Select/Right button to select the Language setting. The default
setting ENGLISH will appear, flashing (Fig. 48).
5. Press the Advance/Left button to scroll through the Language setting op-
tions until you arrive at the one you prefer.
6. Be careful to ensure that the language selection flashing is the one that
you prefer before you press the Select/Right button.
. Press the Select/Right button to save the Language chosen and return to
the Surface Mode.
=]
750GT
Fig. 47 - Set Language
Fig. 48 - Language
41
a
ENE G T £ a Wl pp pen
2 \
“a an rm ee A
Fig. 49 - Language
(Set: Link - German)
42
Language Correction Procedure
If you accidentally selected a language that you do not prefer or understand,
you may find it very confusing to navigate further in the Mode Menu or under- .
stand the Messages (Fig. 49).
To correct the language, it is recommended that you wait 5 minutes to allow
the Display Module to default to the Surface Mode, then carefully perform the
following procedure:
1. Press the Advance/Left button 5 times to arrive at the Set Mode.
2. Press the Select/Right button once to enter Set Mode.
3. Press the Advance/Left button 7 times to arrive at the Language sub-
menu,
4. Press the Select/Right button once to select the Language submenu.
5. Press the Advance/Left button as needed until your preferred language
appears.
6. Press the Select/Right button to save the language chosen and return to
the Surface Mode.
750GT
43
Poor
reception
Poor reception distance.
(Greater than 3 feet)
reception
zone.
44
(50GT
POSITIONING OF THE DISPLAY MODULE
The Transmitter emits a low frequency signal that radiates outward in a semi-
circular pattern that is parallel to the length dimension of the Transmitter. A
coiled antenna inside the Display Module receives the signal when it is posi-
tioned within a zone parallel to, or at a 45 degree angle to, the Transmitter as
shown on page 44. The Display Module cannot effectively receive the signal
when it is held out to the sides of the Transmitter, or held at distances greater
than 6 feet (2 meters) in front of the Transmitter. Best reception is achieved
when the Display Module is within 3 feet (1 meter) of the Transmitter.
When installed into a high pressure port of your first stage regulator, the
Transmitter must be positioned so that it faces horizontally outward from the
tank valve.
LINK INTERRUPTION UNDERWATER
During a dive, you may at times move the Display Module out of the signal
pattern resulting in a temporary interruption of the link signal.
An interruption greater than 15 seconds will cause the Link icon and tank
pressure display to flash (Fig. 50). Also, an audible alarm will sound once per
second until the link is restored. The link will be restored within 4 seconds
after the Display Module is moved back into its correct position,
Fig. 50 - Underwater Link
Interruption
45
IE ross
46
An interruption may also occur while the Display Module is within 3 to 4 feet
(1 meter) of a running dive propulsion vehicle. The link will be restored
within 4 seconds after the vehicle motor is shut off or when the Display Mod-
ule is moved out of this area.
When using a photo strobe, temporary link interruption may occur shortly af-
ter the strobe flashes. The link will be restored in 4 seconds.
A WARNING: During the period of link interruption, the Display
=== Module wiil temporarily loose transmitted pressure related
functions and displays. These will be regained 4 seconds after
the link is restored.
OPERATIONAL MODES
The 750GT can be used either as an Air computer or a Nitrox computer. After |
activation, the Display Module will operate as an Air computer without dis-
playing information associated with oxygen calculations, unless the percentage =
of oxygen (FO?) is 'set' for a numerical value of 21 to 50 %.
Fin WARNING: The percentage of oxygen (FO2) in the nitrox mix
= being used must be set before each nitrox dive.
FO2 MODE
FO2 Set for Air
If you are using 'Air' as your breathing gas, you can verify that 'Air' is the FO2
value by performing the following procedure beginning in the Surface Mode:
1. Press the Advance/Left button once to enter the Mode Menu. MODE:
FO2 will appear, with FO2 flashing (Fig. 51).
2. Press the Select/Right button once to select the FO2 Mode. FO2 Air will
appear, with Air flashing (Fig. 52).
3. Press the Select/Right once to accept Air as the setting. MODE:PLAN
will appear with PLAN flashing.
4. Press the Advance/Left button 5 times to return to the Surface Mode.
When set with an FO2 value of Air’, the 750GT will perform calculations the
same as if FOZ were set for 21% oxygen, internally accounting for oxygen load-
ing for any subsequent Nitrox dives.
Pe
Oxygen related displays, warnings, and the O2 bar graph wil! not appear on
the LCD display when FO2 is set for 'Air' (Fig. 53). To have them appear dur-
ing an Air dive, set the FO2 value at 21%.
5
r
“и
47
48
Е
Fig. 54 - FOZ Default
(after nitrox dive)
Setting FOZ for a Nitrox Dive
You can program the 750GT for nitrogen-oxygen (nitrox) mixtures of 21% to
50% oxygen (02) before each nitrox dive. If FO2 is set at a value of 21%, the
unit will remain set as a '21% nitrox computer’ for subsequent nitrox dives un-
til FOR is set to a higher value, or the Display Module automatically turns off.
Once FO2 is set to a value ‘greater than 21%' to match the nitrox mix being о
used for that nitrox dive, the FOZ value displayed during the FOZ Mode thatis -
accessible 10 minutes after that dive will be 50%, the default value (Fig. 54).
FO2 must be reset for each repetitive nitrox dive, or the value will automati-
cally default to 50 and the dives will be calculated based on 50% O2 for oxygen
calculations and 21% O2 (79% nitrogen) for nitrogen calculations. Once a dive *
is made with the 750GT set as a nitrox computer (FO2 set for a numerical у
value), the unit cannot be programmed to operate as an 'Air' computer until 24 *
hours after the last dive. ‘Air’ will not be displayed as an option in the FO2
Mode.
a WARNING: The 750GT will default to an FO2 value of 50 (%)
tL after a 10 minute surface interval following a nitrox dive.
Therefore, the following procedure must be performed prior to
descent on each and every nitrox dive, even if the percentage ой
oxygen in the nitrox mixtures used remains the same. Be
750GT
To set (enter) a numerical value for the percentage of oxvgen (FO?) in your
nitrox mix, perform the following procedure beginning in the Surface Mode:
1. Press the Advance/Left button once to enter the Mode Menu. MODE:
FOZ will appear with FO2 flashing.
2. Press the Select/Right button once to select the FO2 Mode. If a previous
dive was made that day with the unit set for Air, FO2 and Air will appear,
with Air flashing. If a previous dive was made with the unit set for a nu-
merical value of FO2, FO2 and 50 will appear, with 50 flashing.
3. Press and hold the Advance/Left button, or press it repeatedly, until the
proper value of FO2 appears (Fig. 55). The percentage displayed will ad-
vance 1 (%) per second from 21 to 50 (%), then display 'Air' again,
4. Once the proper value of FO2 is displayed, press the Select/Risht once to
save the value shown as the setting for that dive. MODE:PLAN will ap-
pear with PLAN flashing.
5. Press the Advance/Left button 5 times to return to the Surface Mode.
PLAN MODE
AERIS strongly recommends that you access the Plan Mode prior to
every dive to review the Planning Sequence that will help you plan
your dive as required to avoid exceeding no decompression, or OXY-
gen exposure limits. This is especially important for repetitive dives, when Fig. 55 - Setting FO2
the Planning Sequence will indicate for you the 'adjusted' no decompression
49
dive times that are available to you for your next dive, based on any residual
nitrogen or oxygen accumulation (whichever is in control) following your last
dive and surface interval.
, WARNING: The Planning Sequence predicts only no decom-
à pression times for subsequent dives. Depending on cylinder ;
size, breathing gas consumption, and oxygen accumulation, you
may have less time available than indicated because of breath-
ing gas quantity or other limitations.
To access the Plan Mode, perform the following beginning in the Surface Mode
1. Press the Advance/Left button two times. MODE:PLAN will appear,
with PLAN flashing (Fig. 56).
Fig 57 -FO2 Value Set 2. Press the Select/Right button once to enter the Plan Mode.
If FOZ was set for a numerical value, FOZ and the value set will appear as the =
first screen (Fig. 57), followed by a screen showing the maximum depth that
can be achieved for an oxygen partial pressure (PO2) of 1.60 ATA for that FO2
(Fig. 58).
CHOSE PLAN |
| If FO2 was set for ‘Air’, the PO2 screen will not appear and the 750GT will be-
gin to scroll through the Planning Sequence.
a :
Fig. £ 58 - Max Allowed Depth
50
(50GT
The 750GT scrolls through the Planning Sequence displaying a sequence of
depths from 30 to 160 feet (9 to 48 meters) in 10 foot (3 meter) increments.
With each depth display, you will see either ‘predicted’ no decompression limits
based upon your previous dive profiles (if calculated to be nitrogen controlled),
or ‘predicted’ oxygen tolerance limits based upon either a single dive oxygen
dose or your 24 hour accumulation of oxygen (if calculated to be oxygen con-
trolled). |
Information displayed includes Previous Dive #, Depth, Dive Time available at
that depth which includes descent time at a rate of 120 feet (36 meters) per
minute, Plan Mode icon, and the message MODE: PLAN.
No decompression times are only displayed for depths where there is at least 3
minutes of dive time available at that depth, taking into account a descent rate
of 120 feet (36 meters) per minute. Depths greater than the maximum depth
that can be achieved with a partial pressure of oxygen (PO2) of 1.60 ATA will
not be displayed.
After scrolling once through depth and dive times available, the 750GT will
automatically return to the Surface Mode. Plan Mode can be accessed and the
sequence repeated as often as you choose. If you wish to interrupt the Plan-
ning Sequence to return to the Surface Mode, you may do so at any time by
pressing either control button.
51
a, 7
Me
52
“ ADIE : PLAN —
“Fig. 61 - Max Daily O2
Limit Exceeded
Prior to a Repetitive Nitrox Dive
H the segments of the Nitrogen Bar Graph are displayed during the Planning
Sequence (Fig 59), that next dive is calculated to be controlled by nitrogen
loading.
If the segments of the O2 bar graph are displayed Planning Sequence (Fig. 60),
that next dive is calculated to be controlled by oxygen loading.
The 750GT will store oxygen accumulation for up to 10 dives conducted during
a 24 hour period. In the event that the maximum limit for oxygen loading has
been exceeded for that day (24 hour period), all of the segments of the O2 bar
graph will be displayed (Fig. 61). Depth and Time displays will not appear un-
til the O2 bar graph recedes into the green (normal) zone (i.e, your daily oxy- :
gen dosage decreases an amount equivalent to the amount accumulated during
the latest dive completed).
#25 WARNING: The 750GT must be manually activated and be in
== an operating mode prior to start of a dive. The unit will not ac-
tivate automatically by immersion in water. Also, FO2 must be
set prior to commencing each nitrox dive.
чи”
NO DECOMPRESSION DIVE MODE
After it has been manually activated and completed its diagnostic checks, the
750GT will enter the No Decompression Dive Mode when you descend deeper
than 5 feet (1.5 meters). No Decompression Dive Mode (Fig. 62) can be recog-
nized by the No Decompression Dive Mode icon (Pig. 62a). Also displayed are
Tank Pressure, Current Depth, and the applicable bar graphs.
If you set the Alternate display option 'ON' during setup, the values of Tem-
perature, Elapsed Dive Time, and Maximum Depth will be displayed continu-
ously in the lower screen (Fig. 62), unless overridden by more critical informa- Fig. 62 - No Decompression
tion. If vou set the Alternate display option 'OFF" (Fig. 63), the values can be Dive Mode (Alternate ON)
viewed by depressing the Select/Right button. Time of Day will appear briefly
when the button is released.
To activate the backlight during a dive. press the Advance/Left button. The
display will be illuminated as long as the button is depressed plus 10 seconds
after it is released (for a maximum illumination time of 15 seconds).
As your depth and/or elapsed dive time increase, the Nitrogen Bar Graph will
fill with segments (green toward red) to represent the absorption of nitrogen;
and if FO2 was set for a value other than Air’, the O2 bar graph will fill with
segments (green toward red) to represent oxygen accumulation for that dive, Fig. 63 - Alternate OFF
or 24 hour period, whichever is greater.
53
Deco Zone
E pr bina Ea i E
aa AE ERA ON
1 OFT 01 |
Fig. 64 - Decompression
Dive Mode
54
The Gas Time Remaining bar graph will recede from green toward red as
breathing gas time remaining decreases from 60 to 0 minutes. Segments of ВЕ
the Breathing Gas Consumption and Ascent Rate Indicator bar graphs fill (and
recede) as their respective rates increase (and decrease) throughout the dive.
A WARNING: Every effort should be made to keep all of the bar
Co graphs in the green throughout your dives to reduce your risk
of exposure to decompression sickness and oxygen toxicity.
DECOMPRESSION DIVE MODE
The 750GT provides information that will help you avoid, or if necessary, man- ВЕ
age emergency decompression,
The Decompression Dive Mode activates when the No Decompression Limits
are exceeded and the Nitrogen Bar Graph enters the red decompression zone
(Fig. 64).
Decompression Dive Mode is described on page 74.
T50GT
VIOLATION MODES
The 750GT enters Violation Modes when it is unable to predict an ascent pro-
cedure,
Violation Modes are described beginning on page 76.
GAUGE MODE
If the 750GT enters Gauge Mode (a permanent violation), it will not display
information relating to nitrogen or oxygen loading for the remainder of that
dive or for subsequent dives conducted during the 24 hour period after surfac-
ing.
Gauge Mode is described on page 80.
ASCENDING TO THE SURFACE
While ascending to shallower depths, the segments that have filled up the Ni-
trogen Bar Graph will begin to recede (Fig. 65}, offering a graphic representa-
tion of your multilevel diving capability. A safety stop made between 15-
20 feet (5-6.5 meters) is strongly recommended as a standard proce-
dure before completing your ascent.
Fig. 65 - Nitrogen Bar Graph
Receding
55
TG e755
Fig. 66 - Ascent "Too Fast
56
If you inadvertently entered Decompression Mode, you must not com-
plete your ascent until the Nitrogen Bar Graph is at least inside the
yellow Caution Zone.
You should make every effort to complete all of your ascents with the Nitrogen Ш
Bar Graph inside of the green zone.
While you cannot provide a guarantee against the occurrence of de-
compression sickness, you may choose your own personal zone of
caution based upon your individual age, physique, excessive weight,
training, experience, etc. to reduce the statistical risk.
Ascending Too Fast
The Ascent Rate Indicator shows how fast vou are ascending. When you ex-
ceed the maximum recommended ascent rate of 60 feet (18 meters)per minute, ©
the bar graph will enter the red (Too Fast) zone (Fig. 66), and you will be
alerted by the segments flashing. You will also be alerted by an Audible Alarm -—:
(1 beep per second), and the Message TOO FAST will appear flashing. The
warnings will stop when your ascent rate is slowed.
750GT
ALTITUDE DIVING
The mathematical model within the 750GT accounts for the reduced No De-
compression dive time available at higher elevations based on NOAA (National
Oceanic and Atmospheric Administration) guidelines. When diving in high al-
titude lakes or rivers from 2,000 to 14,000 feet (610 to 4,268 meters), the
750GT will adjust automatically, providing corrected depth and reduced No
Decompression and Oxygen Exposure times,
WARNING: If activated above 14,000 feet (4,268 meters), the
244 Message TOO HIGH will appear and the unit will shut off.
When above 2,000 feet (610 meters), depth calibration is automatically
changed to read in 'feet of freshwater’ rather than feet of seawater’
A WARNING: Until it has shut itself off, you must not use the
“= 750GT at a different altitude than the altitude where it was
originally activated. Doing so will result in an error equal to
the difference in barometric pressure, and possibly a false dive
mode with erroneous data. RESPONSIBLE DIVER
at all times.
More about altitude diving is presented on page 103.
57
IH e705
(This page intentionally left blank.)
58
750GT
Fig. 67 - Transition Period
60
POST DIVE SURFACE MODE
When you ascend to 3 feet (1 meter) or shallower, the 750GT will enter Sur-
face Mode (Fig. 67) and begin counting your surface interval.
TRANSITION PERIOD
The first 10 minutes is, in affect, a Transition Period during which time:
* The main time display starts counting Surface interval (colon flashing).
* The Surface Mode icon will appear (flashing).
* The Nitrogen Bar Graph will indicate current nitrogen loading.
* The O2 bar graph will indicate current oxygen loading, if the dive was a
nitrox dive (FOZ set for a numerical value).
Temperature and Time of Day will also be displayed.
If you descend during the 10 minute Transition Period, time underwater will
be considered a continuation of that dive. The time at the surface (if less than =
10 minutes) will not be added as Elapsed Dive Time. During the 10 minute
Transition Period, the Log Mode is accessible in the Mode Menu and will dis-
play that dive's data, however, the data will not be stored in the unit's memory —
until the 10 minute period on the surface is completed. No other modes are
accessible in the Mode Menu during the 10 minute Transition Period.
Once 10 minutes have elapsed, the Surface Mode icon and Surface Interval
time display colon will stop flashing (Fig. 68) indicating that the dive and tran-
sition period are completed, and a subsequent descent will be considered a new
dive. Other information will continue to be displayed as previously described
and you will have full access to the Mode Menu.
FO2 MODE
If the 750GT was set for FO2 of 'Air' or 21% prior to the dive, it will stay set
for 'Air' or 21%, respectively, unless you reset it to a higher numeric value
prior to the next dive. If it was set for a numeric value of FO2 greater than
21% (22 to 50 %) prior to the dive, the FO2 value displayed after the dive will
default to 50 % (Fig. 69) and subsequent dives will be calculated based on 50%
oxygen for oxygen calculations and 21% oxygen (79% nitrogen) for nitrogen
calculations, unless you set FO2 for another value.
To set FO2, refer to instructions on page 49.
Remember!! You must set the FO2 to match the specific nitrox mix
for each nitrox dive, even if the percentage of oxygen in the mix is
the same as the previous.
El iE « H md
Fig. 68 - Surface Mode
(> 10 min)
Fig. 69 - FO2 Default
61
62
PLAN MODE
When you access the Plan Mode after a dive -
* MODE:PLAN will appear
When you enter the Plan Mode after a dive -
* The FO2 screen will appear displaying the FTO2 set point value that you
entered for the next dive.
* The PO2 screen will then appear indicating the maximum depth allowed
for the FO2 set point and your 24 hour oxygen accumulation (dose).
The Time to Fly screen (described on page 63) will then appear.
* The Planning Sequence will then begin.
The Planning Sequence will show 'adjusted' no decompression limits based on
residual nitrogen calculated to be remaining from previous dives. Calculated
dive times and the maximum allowed depth displayed will increase as the real
time surface interval increases after completion of a dive,
The Planning Sequence will only scroll to the maximum depth allowed by the
nitrogen or oxygen limit, whichever is in control. The respective bar graph
will be displayed to indicate which is in control.
To access the Plan Mode, refer to instructions on page 50.
750GT
Time to Fly
As you should be aware from your own training, the longer you wait
to fly (or travel to higher elevations) after diving, the more you will
reduce your exposure to decompression sickness.
The Time To Fly counter begins counting down 10 minutes after the last dive
has ended to assist you with deciding when encugh surface time has elapsed to
fly. It appears prior to the Planning Sequence when vou access the Plan Mode,
and shows the word 'FLY' with a countdown (Fig. 70) that starts at 23:50
(hr:min) and counts down to 12:00 (hr:min).
Twelve hours after the last dive, the Surface Mode will disappear from the
screen, and the Fly Mode will be displayed continuously, with the final 12 hour
countdown from 11:59 to 0:00.
After a surface interval of 12 hours, you may choose to fly (or travel to higher
elevations), provided that your dive profile(s} did not enter decompression.
If your diving involved decompression or a repetitive, multi day profile, it is
strongly recommended that you wait a full 24 hours after your last dive to add
a greater degree of protection.
Fig. 70 - Time to Fly
(first 12 hours)
63
Fig. 71 - Log Mode Icon
WE Mal 7 ZE
| MODE: LOB |
Fig. 72 - Dive Log Mode
64
DIVE LOG MODE
Dive Log Mode, identified by the Dive Log icon (Fig. 71a), can be accessed us-
ing the Mode Menu while on the surface. Information from your 12 latest |
dives is stored in the Log for viewing, giving you the opportunity to record data
in your log book before it is eventually overwritten by subsequent data. After
12 dives are accumulated, each subsequent dive will overwrite the oldest dive
that exists in the log, ie, the 750GT will add the most recent dive while delet-
ing the oldest. Dive Log information will be retained when batteries are re-
moved from the Display Module.
Dives are displayed in a reverse sequence that starts with the dive most re-
cently conducted back to the oldest of the 12 dives stored. Thus, your most re-
cent dive will always be the first shown in the sequence.
To eliminate confusion, each dive is separately ‘stamped’ (identified) with the
date on which it was made and the time of day that the dive started.
Each dive has four log screens that display date, time, nitrogen related data,
and oxygen related data, respectively. To access the Dive Log Mode, follow
this procedure, beginning in Surface Mode:
1. Press the Advance/Left button 3 times to advance to the Log Mode.
MODE: LOG will appear with LOG flashing (Fig. 72).
2. Press the Select/Right button once to select (enter) the Log Mode. If you
accidentally pass Log Mode, press the Select/Right button repeatedly un-
til MODE:LOG appears.
3. The first screen to appear (Fig. 73) will display the most recent dive re-
corded, identified by the Log Mode icon, the dive Number and dive Date .
4. To bypass the dive currently being displayed to view an older dive, press x
the Select/Right button until the desired dive ig displayed, identified by 100 es
the dive number and date of the dive, Fig. 78 - Log (first screen)
5. Press the Advance/Left button once more to display the Time of Day (Fig. ——
74) when the dive started.
6. Press the Advance/Left button once more to view the information associ-
ated with nitrogen (Fig. 75). Displayed will be: Log Mode icon, dive Num-
ber, Surface Time between that dive and the one previous to it, lowest
water Temperature during the dive, Elapsed Dive Time, and Maximum
Depth.
E
TRENT EE
rei
gd fii
Cre ii TEA
If the dive shown in the log display was the only one of the day, Surface
Time will represent the time between initial activation and the beginning
of the first dive. Also shown will be the tissue nitrogen loading at the
time you surfaced from the dive (N itrogen Bar Graph), the maximum
rate of breathing gas consumption (Gas Consumption Indicator), and the ;
maximum rate of ascent at any time during the dive (Ascent Rate Indica- EEE E
tor). Fig. 75 - Log (third s
65
7. Press the Advance/Left button once more to view the information associ-
ated with oxygen (Fig. 76). Displayed will be: Log Mode icon, dive Num-
ber, FO2 symbol and the value that FO2 was set at for the dive. If FO2
was set for a value other than ‘Air’, the POZ symbol and value of the
maximum partial pressure of oxygen attained during the dive will also be
displayed. Also shown will be the oxygen loading (02 bar graph) at the
time you surfaced from the dive (maximum for that dive or 24 hour pe-
riod, whichever was greater at the time). The O2 bar graph will also dis-
play the segment that represents the maximum level of oxygen exposure
(dose) that you achieved during that dive.
8. Press either button to advance to the first screen (Date) of the next dive
in the Logs reverse sequence.
To exit the Log Mode, press the Select/Right button repeatedly to advance
through all recorded dives and return to the Surface Mode.
Fig. 76 - Log (fourth screen)
66
HISTORY MODE
The History Mode offers a convenient summary of your 750GT computer since
it was originally purchased, or last received factory service. Information pro-
vided on three sequential screens includes total number of all dives, total num-
ber of decompression dives, total elapsed dive time in hours, deepest maximum
depth, and total number of violation dives.
To access the information provided in History Mode, follow this procedure, be-
ginning in the Surface Mode:
1.
2.
. Press the Advance/Left button once to view the second screen (Fig, 79) Fig. 79 - Hist
. Press the Advance/Left button once more to view the third and final
. Press either button to return to the Surface Mode.
Press the Advance/Left button 4 times to advance to the History Mode.
MODE:HIST will appear, with HIST flashing (Fig. 77).
Press the Select/Right button once to select (enter) the History Mode. O ———
The first screen (Fig. 78) will show the No Decompression icon, total | sam |
number of dives, total elapsed dive time, and maximum depth. Ea e
Pi
iia mai aire
mé E DT AE E
o
Eves ihe ie bat
ory (second
that shows the Decompression Dive icon and the total number of Decom- ET rps
pression dives. Total elapsed dive time and maximum depth will remain Г ‘999
on display. +
screen (Fig. 80) that shows the Dive Mode icon and the total number of
dives during which the 750GT entered a Violation Mode.
is TARO TL
screen)
67
Fig. 81 - External Access
Mode
Fig. 82 - EACC Countdown
68
щи”
EXTERNAL ACCESS MODE (EACC)
Using special infrared linking hardware and a unique PC software program,
data from your dives can be downloaded (copied) from your 750GT into an
IBM compatible PC program running on a Windows® 95 or Windows® 98 oper-
ating system. Instructions for performing the interface and download are pro-
vided with the hardware and software package that is available separately
from your Authorized AERIS Dealer. Ask for Dive Downloader for 750GT.
The software program provides dive profile data, and nitrogen and oxygen
loading information that was sampled throughout the dives downloaded.
Once you have acquired your Downloader package, to access the External Ac-
cess Mode, follow this procedure, beginning in the Surface Mode:
1. Press the Advance/Left button 6 times to advance to the External Access
Mode. MODE:EACC will appear, with EACC flashing (Fig. 81).
2. If you are going to download information, follow the procedures described ----
in the Dive Downloader User's Manual.
3. If you are not going to download information, press the Advance/Left but-
ton once to return to the Surface Mode. If you press the Select/Right but-
ton once, the letters EACC will appear with a countdown from '8' to '0'
(Fig. 82). After counting down to '0', the 750GT will revert to the Surface >
Mode.
750GT
69
/ DEC OMPRES SION \
RULES
ARE NOT MEANT
TO BE BENT
EMERGENCY DECOMPRESSION
There are few legitimate excuses for making unplanned Decompression dives,
and the consequences of this type of diving can be severe. Decompression div-
ing requires special training and support. The 750GT is intended for use
by recreational divers not engaged in intentional decompression div- =
ing. Decompression features are provided only for emergency situa-
tions. By entering decompression, you automatically impose a “ceiling” above
you which you cannot immediately ascend beyond, denying you free access to
the surface.
Professional military and commercial divers plan ahead for this situation by
ensuring that they have complete surface support, including a redundant
breathing gas supply for emergencies. They also navigate very carefully
throughout their dive to ensure that they begin and complete their ascent
while maintaining contact with a rope or a line to the surface. This is neces-
sary for making a well controlled ascent. The 750GT is not intended for
use by military or commercial divers.
By making an unplanned Decompression dive without the necessary prepara-
tion and training, you will have placed yourself in an unnecessarily danger-
ous situation. Consider also, that one mistake can quickly be compounded by
several others.
The 750GT is a sophisticated instrument designed with capabilities that go be-
yond the range of recreational diving with compressed air. It should not be
considered, however, that these built-in capabilities provide any im-
plied approval or consent from AERIS for individuals to exceed the
defined limits of recreational dive profiles, as agreed on by all inter-
nationally recognized training agencies.
The 750GT is designed to help you by providing a complete representation of
how close you are to entering decompression. In the event that you do inad-
vertently enter decompression, the red zone of the Nitrogen Bar Graph (Fig.
83a), the 750GT can provide you with limited information to help you ascend
to the surface, if you follow the instructions given in this section.
, WARNING: Existing data for making planned decompression
3 dives is extremely limited, and virtually nonexistent for repeti-
tive decompression diving. You must therefore avoid decom-
pression diving and allow a surface interval of at least 24 hours
before reentering the water in the event a dive requiring emer-
gency decompression is made.
If you're not careful, it is possible to enter decompression rapidly,
whether at deep depths or during repetitive dives.
Fig. 83 - Decompression
Mode
71
Upon entering decompression, you must immediately change the focus of your
me enter the red Decompression zone, you should immediately begin a safe con-
FU |! trolled ascent, 60 feet (18 meters) per minute or slower, to a depth slightly
nn 2 SE deeper than or equal to the required ceiling Stop Depth (Fig. 84).
DA ANRIXNNZONNICENAE
= МЕ Рос сон
oa you continue the dive at a depth more than a few feet (1 meter)
deeper than the required ceiling Stop Depth, your exposure to de-
compression sickness will increase, and you will risk entering a viola-
tion mode and losing the information needed to ascend properly.
GAS TIME REMAINING DURING DECOMPRESSION
Breathing Gas Time Remaining will fluctuate throughout your dive, decreas-
ing as you dive deeper or breath heavier, and increasing as you ascend to shal-
lower depths or relax your breathing efforts. Once you enter Decompres-
sion Mode, you will need to refer to the Gas Time Remaining bar
graph for Breathing Gas Dive Time Remaining information.
When Breathing Gas Time Remaining decreases to 5 minutes, the Tank Pres-
sure numerals will flash (Fig. 85) and a Double Beep will sound. This means
that only 5 minutes remain before your breathing gas supply will be reduced to:
the minimum level necessary to perform the required decompression stops and ~~
still provide a tank pressure reserve upon surfacing.
Fig. 85 - Gas Time Remain-
ing (5 minutes)
72
dive to getting safely back to the surface. Upon seeing the Nitrogen Bar Graph .-
When the Breathing Gas Time Remaining decreases to zero minutes, the Au-
dible Alarm will continuously beep once per second (Fig. 86), signaling the
need for an immediate safe ascent to your first decompression stop. However,
there is no need to panic. The 750GT has allowed for the breathing gas you
will consume during a safe ascent including the required decompression stops
and still provide the surfacing tank pressure reserve you chose (entered) dur-
ing setup, e.g. 500 psi.
CAUTION ZONE (NITROGEN BAR GRAPH)
Your dive training taught you not to get too close to the No Decompression
limits. The yellow Caution Zone of the N itrogen Bar Graph (Fig. 87a) offers
you a convenient way to consistently monitor how close you are coming to the
No Decompression limit. AERIS suggests always leaving the water with
the Nitrogen Bar Graph in the green No Decompression zone.
JIN WARNING: Exiting the water with the Nitrogen Bar Graph in
=== the red Decompression zone greatly increases the risk of de-
compression sickness, and may result in injury or death.
Body metabolism varies from person to person, and even from day to day. If
you are feeling less than 100%, or you are in less than perfect physical shape,
use the yellow Caution Zone as a visual reference to place a wider
margin of protection between you and the No Decompression limit.
: aa
S ALARM |
E Аии TA
Mea has EH]
Fig. 86 - Gas Time Remain-
ing (zero minutes)
| 590 120” E
v 003
NAUSEAS
Fig. 87 - Caution Zone
(Nitrogen Bar Graph)
73
Mode
| immosEn ot Ee
| [Eun aana san 6
1580 20
ex 009
man i
en AE SR i
| СЕЙ TLINE
Fig. 89 - Alternate Message
74
DECOMPRESSION DIVE MODE
The 750GT will help you to avoid and manage decompression.
¡ WARNING: AERIS recommends the application of responsible
> diving practices and does not recommend decompression div-
ing, or diving deeper than 130 feet (39 meters), as these prac-
tices will greatly increase your risk of decompression sickness.
Decompression Dive Mode, identified by the flashing bar of the Decompression
Dive icon (Fig, 88a), activates when the theoretical no decompression dive/
depth limits are exceeded causing the Nitrogen Bar Graph to pass the yellow
Caution zone and enter the red Decompression zone. The Audible Alarm will
emit a double beep to alert you.
Information displayed includes required ceiling Stop Depth and Time (Fig.
885), Tank Pressure, Current Depth, and Total Ascent Time (Fig. 88c) that
includes stop times required at all ceilings and vertical ascent time calculated
at 60 feet (18 meters) per minute. Other bar graphs will continue to represent
their respective information.
The Message CEILING alternates with required Stop Depth and Time (Fig.
89).
750GT
The amount of decompression credit time that you receive is dependent on
depth, with slightly less credit given the deeper you are. Still, you must
never ascend shallower than your decompression ceiling. Doing so
will greatly increase your risk of decompression sickness, and place the
750GT into a Conditional Violation Mode described later. When coping with
surge and swells, it may be difficult to stay at an exact depth. You should stay
slightly deeper (Fig. 90a) than the required stop depth indicated (Fig. 90b) un-
til the next shallower stop depth appears. Then, you can ascend to, but not
shallower than, that indicated ceiling stop depth.
Once you have performed the required decompression, the 750GT will switch
to the No Decompression Dive Mode, allowing additional time underwater.
Though more time is theoretically available, it is strongly recommended that a
you spend the remainder of the dive continuing to decompress at, or slightly
deeper than, 10 feet (3 meters). This will let the Nitrogen Bar Graph recede
further into the yellow Caution zone or green No Decompression zone, helping
you reduce your tissue nitrogen loading as much as possible.
7, WARNING: If you exceed certain limits, the 750GT will not be
3 able to tell you how to get safely back to the surface. These
situations will make the 750GT enter Violation Modes and must b
be avoided at all costs. They exceed tested limits and can result
in loss of some 750GT functions for 24 hours after the dive in Fig. 90 - Managing a Stop
which a violation occurred.
75
VIOLATION MODES
The Violation Modes that the 750GT can enter, depending on the situation,
are termed Conditional, Delayed, and Immediate. Gauge Mode and Perma-
nent Violation Mode are continuations of these Violation Modes. It is impor-
tant to understand each different Violation Mode and how to carry out emer-
gency procedures in the event you enter one.
CONDITIONAL VIOLATION MODE
The 750GT will alert you to the possibility of losing decompression manage-
ment abilities by entering the Conditional Violation Mode. If properly
handled, the Conditional Violation Mode can assist you in getting back to the
surface and allow continued use of the 750GT. The situation that will force
the 750GT to enter a Conditional Violation Mode is: Ascent to a Depth
Shallower (Fig. 91a) than the Required Decompression Ceiling.
A momentary rise above the ceiling, such as with a surge or swell, could cause
this to happen. Therefore you should stay slightly deeper than the exact ceil-
ing Stop Depth, watching the 760GT closely when managing decompression.
The Audible Alarm will beep once per second and the Messages CEILING
Fig. 91 - Conditional Viola- and VIOLATION will alternately appear until you descend below the re-
quired decompression ceiling Stop Depth.
tion (above ceiling)
76
aa
750GT
if you descend below the required decompression ceiling before 5 minutes have
elapsed, the 750GT will continue to function as if no violation had occurred. In
this case, no off-gassing credit will be given, and for each minute above the ceil-
ing 1'/, minutes of penalty time is added to decompression stop time.
The added penalty decompression time will have to be ‘worked off first, before
obtaining off-gassing credit. Once the penalty time is worked-off, and off-gas-
sing credit begins, required decompression Stop Depths and Time will decrease
and the Nitrogen Bar Graph will recede into the Caution zone and revert to the
No Decompression Dive Mode.
If you stay above (shallower than) the required ceiling Stop Depth for more
than 5 minutes, the Nitrogen Bar Graph segments will flash and the Delayed
Violation Mode will be entered.
DELAYED VIOLATION MODE
Three conditions will cause the 750GT to enter the Delayed Violation Mode: +
e ERE na Ral AE] eb ph rd Ta
| CEILIN |
1. You remain above the required Decompression Ceiling Stop Depth |) EEILIMB O |
for more than 5 minutes (Fig, 92). т —
The Audible Alarm will beep once per second and the Messages CEILING and Fig. 92 - Delay ed Violation
VIOLATION will alternately appear until you descend below the required ceil- (above ceiling >5min)
77
Fig. 93 - Delayed Violation
(>60 FT ceiling required)
78
ing Stop Depth. You would then need to follow the Stop Depths and Times to-
ward the surface as the Nitrogen Bar Graph recedes into the Caution zone.
2. Your necessary decompression requires a ceiling Stop Depth be-
tween 60 feet (18 meters) and 70 feet (21 meters).
In this situation the Audible Alarm will emit One Long Beep, the Nitrogen Bar
Graph will flash, and the Messages EXCEEDED and CEILING alternately
flash (Fig. 93) four times. Total Ascent Time needed to get back to the surface
will still be displayed numerically in the Main Time display.
To get back to the surface, you must safely ascend to just deeper than 60 feet
(18 meters) staying as close to 60 feet (18 meters) as possible without causing
the Messages to flash. After waiting until the required ceiling Stop Depth dis- :
play indicates 50 FT/15 M, you can ascend to, but no shallower than 50 feet (15 ~~
meters) and continue decompressing. As the required ceiling Stop Depth dis- -
play indicates 40 FT/12 M, 30 FT/9 M, 20 FT/6 M, and then 10 FT/3 M, you can
ascend to, but no shallower than the reguired ceiling Stop Depth indicated.
After Total Ascent Time reaches zero and the Nitrogen Bar Graph recedes into
the yellow Caution zone, you can surface. To add a greater margin of pro-
tection, AERIS recommends that you wait until the segments of the
Nitrogen Bar Graph are well within the green No Decompression
zone, unless a low Tank Pressure condition requires you to surface.
750GT
3. You descend deeper than 330 feet (99.5 meters).
A NOTE: AERIS reminds you that expanded capabilities of the
== 750GT are provided as safety features to assist you with emer-
gency situations.
Upon descending deeper than 330 feet (99.5 meters), the Nitrogen Bar Graph
will flash and the Current Depth and Maximum Depth displays will only indi-
cate 3 dashes (Fig. 94) until ascent is made to a depth shallower than 330 feet
(99.5 meters), at which time the Current Depth display will be restored. Max
Depth will continue to display 3 dashes. Exceeding the maximum operating
depth is described on page 81.
Five minutes after reaching the surface from a dive in which a De-
layed Violation occurred, the 750GT will enter an Immediate Viola-
tion Mode and revert to Gauge Mode for 24 hours.
IMMEDIATE VIOLATION MODE
\ WARNING: Immediate Violation Mode is entered when a situa-
2 tion totally exceeds the 750GT's capacity to predict an ascent
procedure. These dives represent gross excursions into decom-
pression that are beyond the boundaries and spirit of the Fig. 94 - Delayed Violation
750GT design, and a 750GT should not be used for the dives, (>330 ft / 99.5 m)
79
Immediate Violation Mode occurs when a Decompression Stop Depth
— ee. much greater than 60 feet (18 meters) is required. This situation would
a ЕЙ о i A . , , , i
E (Sr TTT) aagaon | be preceded by entering the Delayed Violation Mode previously described.
BOO 1407
The 750GT cannot accurately calculate decompression times for Stop Depths
much greater than 60 feet (18 meters) and offers no indication of how much
Te “a aaa BRIAN
A ea Co uml time spent underwater would result in the need for greater than a 60 foot (18
| oI OGLATIOA | meter) decompression Stop Depth.
If a ceiling much greater than 60 feet (18 meters) is required, an Immediate
Fig. 95 - Immediate Violation Mode (Fig. 95) will be entered, and you will be alerted by a single
Violation long beep of the Audible Alarm. This situation would be preceded by the De-
layed Violation Mode. The 750GT would then operate with limited functions
{Current Depth, Maximum Depth, and Elapsed Dive Time) in Gauge Mode
during the remainder of that dive and for 24 hours after surfacing.
GAUGE MODE
bn | Underwater, the Gauge Mode is a continuation of the Immediate Violation
re Mode that turns the 750GT into a Digital Instrument without any decompres-
“ru ©2272) gion or oxygen monitoring functions (Fig. 96). The Nitrogen Bar Graph and
the Message VIOLATION flash. The numeric Dive Time Remaining will be
absent from the screen. The Alternate Dive Mode may still be accessed under- oo
water by pressing the Select/Right button.
Fig. 96 - Gauge Mode
(underwater)
80
After surfacing, the Nitrogen and 02 Bar Graphs continue to flash while Sur-
face Mode is displayed (Fig. 97). Gauge Mode does not provide the FO2, Plan,
or Time to Fly features. When Plan Mode is accessed 10 minutes after the
dive, a countdown Timer appears with a “triple dash” display (Fig. 98). The
Timer is to inform you of the time remaining before normal 750GT operation
can resume with full features and functions.
PERMANENT VIOLATION
Entering the Immediate Violation Mode, then Gauge Mode, will result in loss
of all 750GT decompression and oxygen monitoring functions for 24 hours af-
ter that dive. This condition is considered a Permanent Violation.
EXCEEDING MAXIMUM OPERATING DEPTH
Although the 750GT will withstand the pressures found at 330 feet (99.5
meters), the depth that you can still use all of its features could be much shal-
lower.
/N WARNING: The maximum recommended sport diving depth
fa limit is 130 feet (39 meters). Any deeper dive should be
avoided. Special training, equipment, and support are neces-
sary for this type of diving.
Fig. 97 - Gauge Mode
{on surface)
Fig. 98 - Countdown Timer
(10 min after surfacing)
81
presea ce ee een
82
Fig. 99 - Qut of Range
(>330 ft / 99.5 m))
The maximum depth the 750GT will display all of its features is 330 feet (99.5
meters). Upon exceeding a depth of 330 feet (99.5 meters), the Nitrogen Bar
Graph will flash, and Current Depth and Max Depth displays will only indicate
and flash three dashes ( - - - ) signifying that you are 'Out of Range’. Also, the
Message VIOLATION will appear alternating with the lower screen displays
(Fig. 99). The numeric display for Current Depth will reappear when you as-
cend shallower than 330 feet (99.5 meters). You will also enter the Delayed
Violation Mode previously described. For the remainder of that dive, and in
the Log for that dive, only three dashes will be displayed as the value for Maxi-
mum Depth.
OXYGEN EXPOSURE
There are few legitimate excuses for exceeding the maximum limits for expo-
sure to oxygen, and the consequences of CNS (Central Nervous System) oxy-
gen toxicity can be severe, resulting in Gran Mal convulsions and drowning.
Diving with enriched nitrogen-oxygen (nitrox) mixtures requires special train-
ing and certification.
AZ WARNING: The oxygen features of the 750GT are intended for
£23 use only by recreational divers trained for nitrox diving by an
instructor certified by a recognized training agency to teach
diving with nitrox. The 750GT is not intended for use by mili-
tary or commercial divers.
150GT
By making a nitrox dive without the necessary training, preparation, and
equipment, you will have placed yourself in an unnecessarily dangerous situ-
ation. The 750GT is a sophisticated instrument designed with capabilities that
go beyond the range of recreational diving with compressed air. It should
not be considered, however, that these built-in capabilities provide
any implied approval or consent from A- for individuals to exceed the
defined limits of oxygen exposure, as agreed on by all internationally
recognized nitrox training agencies. Nitrox diving should therefore
be strictly controlled.
PARTIAL PRESSURE OF OXYGEN
As depth increases during the dive, the partial pressure of oxygen increases.
As you approach the depth limit for the FO? value set before that dive, the
750GT will alert you and display the PO2 level while you reduce oxygen partial if я
pressure according to your training. i { (Вт
ки o
High PO2 Dive Mode : E Ме ' i
The 750GT enters the High PO2 Dive Mode when partial pressure of oxygen
becomes equal to or greater than 1.40 ATA. The Audible Alarm will emit a
double beep, and the PO2 value and the symbol PO? will appear in the lower
portion of the display (Fig. 100). They will remain on display until partial Fig. 100 - High PO2 Mode
pressure of oxygen decreases below a value of 1.40 ATA. ( 1.40 ATA)
83
Fig. 101 - High PO2 Mode
( 1.60 BAR)
Fig. 102 - O2 Bar Graph
84
If partial pressure of oxygen continues to increase, the value of PO2 displayed
will increase from 1.40 toward a value of 5.00 ATA in increments of .01' ATA.
When PO2 reaches the maximum limit of 1.60 ATA, the Audible Alarm con-
tinuously emits one beep per second, and the large red segment of the 02 Bar
Graph, the PO2 value, and PO2 symbol will flash continuously as a warning
(Fig. 101) until the level of PO2 decreases below 1.60 ATA.
In the event that you enter High PO2 Dive Mode, you must immediately focus
on reducing the partial pressure of oxygen by slowly ascending to a shallower
depth at a safe rate in accordance with your nitrox training. If you continue
the dive at your current depth, or descend deeper, your exposure to
CNS oxygen toxicity will increase.
OXYGEN ACCUMULATION
it is also important that you understand that conducting repetitive dives using -
enriched nitrogen-oxygen (nitrox) mixtures can lead to oxygen buildup, reduc-
ing oxygen tolerance while increasing the risk of pulmonary oxygen toxicity.
The 02 Bar Graph (Fig. 102a) provides a visual representation of oxygen accu-
mulation for either that dive or 24 hour period, whichever is greater.
AERIS strongly recommends that you avoid exceeding oxygen expo-
sure limits, and reminds you that nitrox diving requires special train- — -
ing and understanding of the effects of oxygen toxicity.
\ WARNING: In the event that you exceed the maximum per dive
d allowable oxygen exposure (dose), it is recommended that you
allow a surface interval of at least 2 hours before reentering
the water. If you exceed the maximum 24 hour period allow-
able oxygen exposure (dose), you must allow a surface interval
of at least 24 hours before reentering the water.
HE ET Ame
rH a minos
i
: o
Li
Y DRRNSENIRR
HIGH OXYGEN ACCUMULATION LL |
Your nitrox dive training taught you not to get too close to the oxygen toler-
ance limits. The O2 Bar Graph provides you with a convenient graphic repre-
sentation of your oxygen accumulation, displaying either oxygen accumulated
during that dive or during your repetitive dives conducted during that 24 hour
period, whichever of the two is greater at that time.
Fig. 103 - High Oxygen
Accumulation (warning)
As your accumulation increases, segments will add to the O2 Bar Graph.
When it enters the yellow Caution zone, the Audible Alarm will emit a double
beep as a warning (Fig. 103). If accumulation exceeds the limit of oxygen tol-
erance (Oxygen Dive Time Remaining is 0:00), the Audible Alarm will emit a
continuous one beep per second, and the O2 Bar Graph will enter the red Dan-
ger zone and the full bar graph will flash as a warning (Fig. 104).
Fig. 104 - High Oxygen
Accumulation (alarm)
You must then immediately focus on making a safe controlled ascent to the
surface to prevent further exposure.
85
As your accumulation (dose) decreases during your surface interval, the 02
Bar Graph will gradually recede into the yellow Caution and green Normal
zones. AERIS suggests always keeping the O2 Bar Graph in the green zone.
N WARNING: DO NOT allow the O2 Bar Graph to enter the red
===2 (Danger) zone. Doing so greatly increases the risk of CNS oxy-
gen toxicity, and may result in serious injury or death.
VIOLATION Body metabolism varies from person to person, and even from day to day. H
you are feeling less than 100%, or you are in less than perfect physical shape,
GAS ALARM use the Caution zone as a visual reference to place a wider margin of
protection between you and the limits of oxygen tolerance.
EXCEEDED WARNING MESSAGES
CEILING
When diving beyond the normal limits of recreational sport diving, it is pos- Lo
TOO FAST sible that you will violate more than one condition at a time, such as exceeding
the maximum recommended ascent rate, ascending above a required ceiling |
TOO DEEP Stop Depth, or exceeding the maximum allowed partial pressure of oxygen. In
these situations, the Message that appears will reflect the most important
warning for that time, allowing more critical warnings to override others of
: lesser importance (Fig. 105). Example: The message TOO FAST will override
Fig, 105 - Message Hierarch ;
8 5 Y the message TOO DÉEP due to the severity of a rapid ascent rate.
86
750GT
UNEXPECTED LOSS OF DISPLAYED INFORMATION
While No Decompression diving, if you find that any major piece of
equipment is not functioning correctly, you must abort the dive im-
mediately and surface slowly in a controlied manner.
If your 750GT stops working for any reason, it is important that you have an-
ticipated this possibility and are prepared for it. This is an important rea-
son to avoid pushing the no decompression and oxygen tolerance lim-
its, and a critical reason to avoid entering decompression. Regardless
of your diving habits, AERIS advises you to dive with additional backup instru-
mentation that can provide the data necessary to properly surface if and when
your primary instruments fail.
As with any other piece of equipment, unforeseen things can happen. By pre-
paring ahead of time, you can spare yourself a great deal of frustration and dis-
appointment.
If you dive in situations where your trip would be ruined or your
safety would be jeopardized by losing the use of your 750GT, an ana-
log or digital backup system or use of standard air (or nitrox) tables
is highly recommended.
87
88
A FINAL WORD OF CAUTION
Although the 750GT represents the latest in user friendly dive com-
puter technology, it cannot force you to understand how to use it.
Before diving with the 750GT, be sure you thoroughly understand its
functions and displays. Contact your local Authorized AERIS Dealer
if you have a question. Above all remember, technology is not a re-
placement for training, experience, and common sense |!
Be a Responsible Diver at all times !!
+
- |
N
90
CARE AND CLEANING
The 750GT is a sensitive electronic instrument. Although it has been designed
to withstand the rigors of diving, it still must be handled carefully to protect it
from shock, excessive heat, chemical attack, and tampering.
The housing is made of an impact resistant resin that is extremely shock resis-
tant but is susceptible to chemical attack and scratches. If the transparent
face becomes scratched, AERIS can replace it, although small scratches will
naturally disappear underwater.
da CAUTION: Never spray aerosols of any kind on, or near, the
#23 750GT. The propellants may chemically attack the plastic.
BEFORE THE DIVE
Be careful not to place the 750GT in an unsupervised, unprotected location
where it might be damaged. Dive computers, and dive trips, can be quickly ru-
ined due to carelessly tossed weight belts or cylinders. Keep your Display Mod-
ule and Transmitter protected from undue shock.
750GT
AFTER THE DIVE
Soak and rinse the Display Module in fresh water following each dive, and
check the low pressure sensor guard cap to ensure that it is free of any debris
or obstructions. For the Transmitter, soak and rinse the regulator in fresh
- water following each dive as you normally would, according to the proper
maintenance procedures prescribed for that model. If possible, use lukewarm
- water to dissolve any salt crystals. Salt deposits can also be dissolved using a
— slightly acidic vinegar/water bath. After removal from a fresh water bath,
place the 750GT under gently running water and towel dry before storing.
Transport your 750GT cool, dry, and protected.
i WARNING: Never, under any circumstances, poke any object
£23 through any slots or holes of the Display Module. Doing so may
damage the depth sensor, possibly resulting in erroneous depth
and/or dive time remaining displays.
ANNUAL INSPECTIONS AND SERVICE
Your 750GT should be inspected annually by an Authorized AERIS Dealer who
will perform a factory prescribed function check and inspection for damage or
— Wear, To keep the 2 year limited warranty in effect, this inspection must be
completed one year after purchase (+/- 30 days). AERIS recommends that you
91
92
continue to have this inspection performed every year to ensure your 750GT is
working properly. A convenient service record is provided in the rear of this
owner's guide. This should be signed by the service technician after each an-
nual inspection or factory service. The cost of annual inspections are not cov-
ered under the terms of the 2 year limited warranty.
di, WARNING: If you are in doubt about the accuracy of your
E 750GT's depth readings, DO NOT attempt to dive with it until it
has been inspected by AERIS Customer Service.
It is possible to damage the 750GT depth sensor if it is not pressure tested
properly. Please take heed of the following warning:
28, WARNING: Never pressure test the 750GT Display Module in
Ex an air environment. Doing so may damage the depth sensor:
possibly resulting in erroneous depth or time readings.
HOW TO OBTAIN SERVICE
Take your 750GT to an Authorized AERIS Dealer.
7% NOTE: The Transmitter and Display Module must be returned
E—— together, regardless of the reported problem or symptom.
To return your 750GT to AERIS:
° Remove the Transmitter from the regulator.
* Package the Display Module and Transmitter together, using a cushion-
ing material to keep them isolated from each other.
* Authorized AERIS Dealers should use an AERIS Product Return Form.
° Include a legible note stating specific reason for return, your name, ad-
dress, daytime phone number, serial number, and a copy of your original
sales receipt from your Authorized AERIS Dealer.
* Send prepaid and insured to the nearest AERIS service facility.
* If you have any questions regarding 750GT service, call AERIS Customer
Service at (510) 346-0010, 8 to 5 PST, or E-MAIL: [email protected].
A NOTE: Previous dive Log and History data will be erased
== whenever your 750GT receives factory service.
BATTERY LIFE
The 750GT battery consumption rate varies throughout periods of operation,
which begin upon activation and continue for 24 hours after surfacing from a
dive. The Transmitter and Display Module consume power any time batteries
are installed in them, even in standby when pressure to the Transmitter is
purged and the Display Module has shut down.
750GT
93
94
The exact number of dives, or hours of operation, that you will obtain with a
set of batteries is subject to variables such as, the number of dives conducted
during an operational period, the manufacturer, model and age of batteries ac-
tually used, the amount of time batteries remain in the Transmitter and Dis-
play Module during periods of inactivity, and the freguency and duration of
backlight use.
, NOTE: Tests and calculations indicate that the number of
% dives that you can obtain from a set of batteries will vary. Ap-
proximately 100 dives could be conducted with the recom-
mended batteries. This is still considered to be substantial
given the convenience of the user replaceable feature.
Due to the convenience of the user replaceable battery feature, AERIS recom-
mends that batteries be removed during extended periods of inactivity ex-
pected to exceed one week, during air travel that is not conducted during re-
petitive dive surface intervals, and during storage.
#% NOTE: The disposable batteries supplied with the 750GT dive
== computer are not covered by the limited 2 year warranty.
LOW BATTERY CONDITION
While in Surface Mode, Low Battery Icons appear on display to alert you of the
need for a battery change for either the Transmitter (Fig. 106a) or Display
Module (Fig. 107a).
If a Low Battery condition occurs while in a dive mode, the icons will not ap-
pear until you surface and the 750GT reverts to Surface Mode. There will be
sufficient battery power (reserve) to complete the dive with full functions and
features. Remaining battery life may also be shortened by a sudden change in
temperature,
AERIS strongly advises that you replace the batteries and DO NOT
attempt to dive with the 750GT when either battery icon remains on
display, and that you replace the batteries of the Transmitter and
Display Module with new prior to any multi-day dive trip.
Fe. WARNING: Adjusted No Decompression Limits (nitrogen and
t= oxygen calculations) will be erased when the Display Module
batteries are replaced between repetitive dives. Also, date and
time settings will have to be reset.
Fig. 107 - Low Battery
(Display Module)
95
BATTERY REPLACEMENT
Whenever replacing the batteries of the Display Module, it is recommended
that you also replace the batteries of the Transmitter, and vice-versa.
Æà WARNING: Damage due to improper battery replacement is
Ex not covered by the 750GT limited 2 year warranty. Follow di-
rections precisely.
* Apply a coin (not a screwdriver) to the recessed slot of the battery cap,
and turn the cap out counterclockwise to remove it from the housing.
Note: The battery compartment should only be opened in a dry and clean — .
environment, with extreme care taken to prevent the entrance of mois-
ture or dust.
* Remove the battery from the cap using care not to lose the spring located
behind the battery. Closely examine the spring and contact area inside
the battery compartment for any signs of corrosion indicating entrance of —
moisture into the unit. If found, return your 750GT to an Authorized
AFRIS Dealer, and DO NOT use it until it has received service.
* To remove the o-ring, press the sides with your fingertips to cause it to
protrude slightly from the groove of the cap and lift it over the head of
the cap. DO NOT use tools to remove,
96
° Closely check the threads of the battery cap and the housing for any signs
of damage that might impair proper threading. If found, return your
150GT to your Authorized AERIS Dealer, and DO NOT attempt to use
until it has received factory service.
* To replace the o-ring, lightly lubricate it with silicon grease and stretch it
slightly to work it down over the head of the cap (Fig. 108), DO NOT roll
it over the threads. Ensure that it is evenly seated inside the groove
above the threads.
* Insert the spring into the cap with the large end first (small end facing
out), and insert the battery into the housing (Fig. 109). For the Trans-
mitter, the positive (+) end of the battery goes into the housing first with
the negative (-) end toward the cap. For the Display Module, the negative
(-) end of the battery goes into the housing first with the positive (+) end
toward the cap.
* Carefuliy insert the battery cap into the housing and turn clockwise by
hand until snug. To ensure correct threading and overcome spring pres-
sure apply slight inward pressure as you begin turning the cap. Apply a
coin to the recessed slot and tighten until secure.
° Activate the Display Module and watch carefully as it performs a full diag-
nostic and battery check, and signal link with the Transmitter.
* Examine the LCD display to ensure it is consistently clear and sharp in
contrast throughout the screen.
Fig. 108 - O-ring
Installation
Transmitter
(-)
Battery
H2AA
3.6 y
Battery Spring
Cap
Display Module
(+)
+ С
Battery
1/2484
3.6v
a tery Sprin g
Cap
Fig. 109 - Battery
Installation
97
FLOODED BATTERY COMPARTMENT
#% NOTE: For any cause of flooding other than a bad o-ring, re-
“== turn the complete 750GT for factory service.
If moisture is found in the battery compartment, it is best to have your 750GT
inspected and cleaned by an Authorized AERIS Dealer.
To perform a repair in the field:
* Remove the battery and discard, DO NOT attempt to reuse.
o Check the o-ring for damage (nicks, cuts, divots, ete.). If found, discard
and replace with new.
» Before replacing the o-ring and batteries, flush the battery compartment
with a solution of 50% white vinegar and 50% water. Rinse with fresh
water, and allow to dry overnight or blow dry with a hair dryer (set at 'no
heat) Prior to installing the spring and battery, ensure that no moisture
is present around the retaining ring located inside the base of the com-
partment.
A NOTE: The retainer ring cannot be removed or replaced by the
38
750GT
~~ TRANSMITTER INSTALLATION INSTRUCTIONS
As an integrated unit, the 750GT requires attachment of its Radio Frequency
— (AF) Transmitter unit to your regulator first stage.
ft, CAUTION: Installing the Transmitter improperly to your regu-
== lator first stage may damage the Transmitter, regulator, or
both. AERIS strongly recommends that installation be per-
formed by an Authorized AERIS Dealer.
To install the Transmitter on your regulator first stage:
| * Remove your current pressure gauge high pressure hose, or high pressure
port plug from the regulator first stage port marked “HP” with the
proper wrench or hex key.
° Very lightly lubricate the o-ring and threads of the Transmitter fitting
with a halocarbon based lubricant such as Christo-Lube MCG111 (pro-
vided in the AERIS battery kit).
* Thread the Transmitter clockwise by hand into the regulator HP port and
tighten until secure with a 5/8” open-end wrench.
° Attach the regulator first stage to a full SCUBA cylinder.
* Open the cylinder valve slowly, listening for gas escaping around the fit-
ting. If gas is leaking, take the complete regulator system to an Autho-
rized AERIS Dealer for inspection and repair.
99
TRANSMITTER COMPATIBILITY WITH NITROX
All AERIS 750GT Transmitters can be used with compressed air and/or nitrogen-oxygen (Nitrox)
breathing gas mixtures in which the percentage of oxygen (02) in the Nitrox mixture does not ex-
ceed 50 (%). However, use with Nitrox (up to 50%) requires that the Transmitter end fitting be
Oxygen Cleaned and fitted with Nitrox compatible parts (i.e., o-ring and lubricant) by an autho-
rized AERIS Dealer Nitrox Service Technician.
Transmitters that have been specifically prepared for Oxygen Service by the AERIS factory, as
identified to be Oxygen Clean and Oxygen Compatible by a special tag affixed to it, can be used
with any nitrogen-oxygen (Nitrox) breathing gas mixture to a maximum of 100 (%) Oxygen.
If a Transmitter prepared by the AERIS factory, and certified and tagged for Oxygen Service, is
subsequently used with compressed air, it cannot then be used with nitrogen-oxygen (Nitrox)
breathing gas mixtures in which the percentage of oxygen (02) in the Nitrox will be greater than
50 (%).
Only the AERIS factory can prepare AERIS 750GT Transmitters for use with nitrogen-oxygen
(Nitrox) breathing gas mixtures in which the percentage of oxygen (02) in the Nitrox will be
greater than 50 (%).
100
750GT
101
102
MORE ABOUT FLYING AFTER DIVING
In 1990 the Undersea and Hyperbaric Medical Society (UHMS) published a set
of guidelines aimed at minimizing the possibility of decompression sickness due *
to flying too soon after diving. The UHMS suggests™ divers using standard air
cylinders and exhibiting no symptoms of decompression sickness wait 24 hours :
after their last dive to fly in aircraft with cabin pressures up to 8,000 feet |
(2,440 meters). * excerpted from “The UHMS Flying After Diving Workshop”
The two exceptions to this recommendation are:
o Ifa diver had less than 2 hours total accumulated dive time in the last 48
hours, then a 12 hour surface interval before flying is recommended.
* Following any dive that required a decompression stop, flying should be
delayed for at least 24 hours, and if possible, for 48 hours.
Since the 1990 UHMS guidelines were introduced, data from the Diver’s Alert
Network (DAN) was introduced that resulted in DAN's position** that “A
minimum surface interval of only 12 hours would be required in order to be
reasonably assured a diver will remain symptom free upon ascent to altitude in
a commercial jet airliner (altitude up to 8,000 feet/2,440 meters). Divers who
plan to make daily, multiple dives for several days, or make dives that require
decompression stops, should take special precautions and wait for an extended :
surface interval beyond 12 hours before flight”.
“* excerpted from “DAN’s Current Position on Recreational Flying After Diving” 0
750GT
Both the UHMS and DAN agree that “There can never be a flying after diving
rule that is guaranteed to prevent decompression sickness completely. Rather,
there can be a guideline that represents the best estimate for a conservative . .
. surface interval for the vast majority of divers. There will always be an occa-
sional diver whose physiological makeup or special diving circumstances will
result in the bends”.
To reduce the risk of developing decompression sickness after a single no de-
compression dive, current guidelines suggest waiting 12 hours prior to expo-
sure to atmospheric pressures equivalent to 1,000 feet (330 meters) above sea
level, or greater. When repetitive dives are conducted during the same day, or
period of days, it is suggested that the interval be increased to a minimum of
24 hours. Note that land travel to higher elevations after diving must also be
considered as an exposure to altitude. 4 ON
DECOMPRESSION
MORE ABOUT ALTITUDE DIVING RULES
ARE NOT MEANT
WARNING: Diving at high altitude requires special knowledge TO BE BENT
E. > of the variations imposed upon divers, their activities, and
their equipment by the decrease in atmospheric pressures.
AERIS recommends completion of a specialized Altitude train-
ing course by a recognized training agency prior to diving in
high altitude lakes or rivers.
и
104
Atmospheric pressure decreases as altitude increases above sea level. Weather
systems and ambient temperature also affect barometric pressures. Conse-
quently, depth reading instruments that do not compensate for the decrease in
pressure indicate depth readings shallower than the depth they are actually at. =
The 750GT automatically compensates for decreased ambient pressure when
activated at high altitudes up to 14,000 feet (4,267 meters). lts program con-
tains a high altitude algorithm that reduces no decompression and oxygen ex-
posure limits to add a larger zone of caution.
Whenever the 750GT is manually activated at altitudes higher than 2,000 feet
(610 meters), it will automatically recalibrate itself to measure depth in feet of -
fresh water rather than feet of sea water. Therefore, when returning to lower
altitudes, diving should not be conducted until the 760GT automatically clears г |)
of any residual nitrogen and oxygen loading and resets to operate at the new
altitude.
da, WARNING: Altitude compensation provided by the 750GT
E takes place when the unit is activated. DO NOT dive at any dif-
ferent altitude until the 750GT shuts off. It will automatically
recalibrate when reactivated at the new altitude.
MORE ABOUT NITROX DIVING
Fy, WARNING: Diving with enriched nitrogen-oxygen (nitrox)
Ex mixtures requires special knowledge of the variations imposed
upon divers, their activities, and their equipment by the in-
creased percentage of oxygen. AERIS recommends completion
of a specialized Nitrox training course by a recognized training
agency prior to diving with any enriched nitrogen-oxygen
(nitrox) mixtures,
Both central nervous system (CNS) oxygen toxicity and pulmonary oxygen
toxicity were taken into consideration when the current maximum limits (Fig.
110) for exposure to oxygen were published by NOAA in the October 1991
NOAA Diving Manual. Although CNS oxygen toxicity is considered the pri-
mary constraint for higher levels of PO2, there are circumstances in which
pulmonary oxygen toxicity can limit exposures.
CNS oxygen toxicity is not considered likely at PO2 levels below 1.30 ATA, It
is however related to the diver's work level. Performing strenuous tasks could
cause the symptoms of oxygen poisoning to occur at PO2 levels lower than
they normally would appear during casual recreational diving.
=”
(50GT
Maximum
Exposure Time
|
PO2 Per Dive Per 24hr
(ATA) (Min) (Min)
|
0.60 720 720
0.70 570 570
0.80 450 450
0.90 360 360
1.00 300 300
1.10 240 270
1.20 210 240
1.30 180 210
1.40 150 180
1.50 120 180
1.60 45 150
Fig, 110 - Oxygen
Exposure Limits
105
106
The nitrox features of the 750GT are intended for use only by recre-
ational divers trained for nitrox diving by an instructor certified by a
recognized training agency to teach diving with nitrox. |
# WARNING: In the event that you exceed the maximum limit of
£23 per dive allowable oxygen exposure, it is recommended that you --
allow a surface interval of at least 2 hours before reentering the
water. If you exceed the maximum limit of 24 hour period al-
lowable oxygen exposure, you should allow a surface interval of
at least 24 hours before reentering the water.
MULTIPLE TISSUE TRACKING
The 750GT tracks twelve tissue compartments with halftimes ranging from 5
to 480 minutes. The Nitrogen Bar Graph always displays the controlling com-
partment that is the only one important at that time. Think of the Nitrogen
Bar Graph as twelve separate transparent displays laid on top of one another
(Fig. 111). The tissue compartment that has filled up fastest is the only one
the viewer can see from the top.
At any particular point, one tissue compartment may be absorbing nitrogen,
while another that was previously higher may be off-gassing. Figure 112 illus- .
trates the point at which one compartment “hands over” control to another
compartment at a different depth. This feature of the Decompression Model is - |
No. of
Segments
15
14
13
12
Displav Seen by the Diver
Tissue
Half-Time
20
40
80
120
169
etc.
Fig. 111 - Nitrogen Bar Graph
Display Seen bv the Diver
No. of
Segments
750GT
Tissue
Half- Time
20
40
Fig. 112 - Control Hand-Over
107
750GT U.S.
Depth NDL-mins, Navy
feet (meters) Eng (Metric) NDL -mins.
30 (9) 260 (283) - = -
35 “mn ee 310
40 (12) 137 (144) 200
50 (15) 50 (84) . 100
60 (18) 57 (58) 60
70 (21) 40 (41) 50
60 (24) 30 (31) 40
90 (27) 24 126) 30
100 (30) 19 (20 25
110 (33) 16 (16) 20
120 (36) 13 da 15
130 (39) 10 (11) 10
140 (42) 9 (9) 10
150 (45) 8 (8) 5
160 (48) 7 (7) 5
170 (51) i 7 5
180 (54) * + 5
190 (57) * + 5
PF The 750GT will not scroll past 160 feet (48
meters}, or when projected bottom /descent time
is less than one minute.}
Fig. 113 - No Decompression Limits
108
the basis of multilevel diving, one of the most important contribu-
tions the 750GT offers you. Take advantage of this feature and
make all of your dives multilevel dives.
NO DECOMPRESSION LIMITS
Note how the No Decompression Limits for the 750GT are con-
trasted with the U.S. Navy limits (Fig. 113). For most depths, the
750GT provides somewhat less no decompression times than the
U.S. Navy Tables. However, while the no decompression limits
may be less, you will receive greatly increased allowable bottom
times as you take advantage of the multilevel dive capabilities of- *
fered by the 750GT. Notice also that the 750GT Planning Se-
quence does not scroll past 160 feet (48 meters).
REPETITIVE DECOMPRESSION DIVING
The decompression model used by the 7T50GT is based on the no
decompression multilevel repetitive dive schedules successfully
tested by Dr. Ray Rogers and Dr. Michael Powell. These tests did
not include repetitive dives deeper than 90 feet (27 meters) or de- =
compression dives. a
750GT
Due to the present unavailability of statistical data, 750GT decompression pre-
dictions are based on U.S. Navy theory . Therefore, pay special attention to
the following warnings.
MM WARNING: AERIS advocates responsible diving practices and
É= does not recommend decompression diving, or diving below 130
feet (39 meters). The decompression capabilities of the 750GT
are intended strictly for emergency use. Decompression diving
is inherently hazardous and greatly increases your risk of de-
compression sickness - even when performed according to the
computer's calculations. In the event that you must make an
emergency decompression dive, you must not make another
dive for at least 24 hours.
#6 WARNING: Using the 750GT, just as using the U.S. Navy (or
== other) No Decompression Tables, is no guarantee of avoiding
decompression sickness, i.e. “the bends.”
CONCLUSION
The 750GT is an informational tool whose entire worth depends on under- RESPONSIBLE DIVER
standing all of its features and functions, and using it correctly. Learn how to at all times.
use it and use it wisely. Thank you for being a responsible diver!!
109
SPECIFICATIONS
NO DECOMPRESSION MODEL
Basis:
+ Modified Haldanean Algorithm
* 12 tissue compartments
Data Base:
* Diving Science and Technology (DSAT) - Royers/Powell
Performance:
» Tissue compartment halftimes {in mins.) Spencer's “M” values
5, 10, 20, 40, 80, 120, 160, 200, 240, 320, 400, 480
» Reciprocal subsurface elimination
* 60 minute surface credit control for compartments faster than 60 minutes
* Tissue compartments tracked up to 24 hours after last dive
Decompression Capabilities:
» Decompression ceilings at 10, 20, 30, 40, 50, & 60 feet
(3, 6, 9, 12, 15, & 16 meters)
Altitude Algorithm:
* Based on NOAA tables
Oxygen Tolerance Limits:
* Based on NOAA tables
110
OPERATIONAL MODES
Modes:
+ a Li + * » + + + +
Activation/Diagnostic
Surface
FOZ Set
PO2 Max Depth
Pian
Log
History
Set, «
* Time (hour, minute, am/pm)
Date (month, day, year)
Alternate Display (on/off)
Unit (imperial / metric
Alarm (depth, air, on/off)
* Link (serial no?
« Language (English, Italian, German, Spanish, French?
КАСС (External Access)
No Decompression Dive
Alternate No Decompression Dive
Decompression Dive
Temperature € Backlight
Violation (conditional, delayed, & immediate}
High PO? Level
High Oxygen Accumulation
(Gauge
Time to Fir
DISPLAY RANGE/RESOLUTION
Numeric Displays:
”
“
»
=.
+
>
+
*
a
*
+
Li
Dive Number
Depth
Maximum Depth
FOZ Set Point
PO2 Value
Gas Time Remaining
No Decompression Time
Decompression Time
Elapsed Dive Time
Surface Time
Dive Log Surface Interval
Time to Fly
Cylinder Pressure
Range:
0-9
0 - 330 £t (0. 99.6 m)
1330 ft (99.5 m)
21-50%
1.40 - 5.00 ATA
0-9 hr. 59 min,
0 - 9 hr, 59 min.
0 - 9 hr, 59 min.
0 - 99 min,
G - li hr. 59 min.
O - 11 hr. 59 min.
23 hr, 50 min, - 0*
SPECIFICATIONS (continued)
Resolution:
1
18 (5 т)
1 ft (.5 m)
1%
01 ATA
1 minute
1 minute
1 minute
1 minute
1 minute
1 minute
1 minute
(* starting 10 min. after the dive)
0 - 8190 psi
(0 - 564 BAR)
GRAPHIC DIVER INTERFACE
Nitrogen Bar Graph
No Decompression zone (green) 1
No Deco Caution zone (yellow)
Decompression Warning zone (red)
segments
e E do
10 psi
(5 BAR}
Oxygen Accumulation (023 Bar Graph
serments
Normal zone (green) 17
Caution zone (yellow) 3
Danger zane (red) 3
Breathing Gas Time Remaining Bar Graph
serments
Normal zone {green} 26
Caution zone (yellow) 2
Danger zone (red) 5
Ascent Rate Indicator
segments = féeet/min.
none 0-10
Normal zone (green) 1 11-20
2 21-30
3 41 - 40
Caution zone (yellow) 4 43 - 50
5 51 - 60
Too Fast zone {red flashing) 6 61 - 90
7 91 - 120
5 >120
Breathing Gas Consumption Indicator
segments
Normal zone {green} 3
Caution zone (yellow) 2
High zone (red) 3
750GT
meters'min,
0-3
3-6
6-9
9.12
12.15
15-18
18-27
27 - 36
>36
141
SPECIFICATIONS (continued)
Special Displays Occurrence
* Audible Alarm Access On demand
* Diagnostic Display Activation
* Out of Range
+ Gauge Mode Countdown Timer
>330 feet (>99.5 meters)
12 - 24 hours (after violation)
OPERATIONAL PERFORMANCE
Function Accuracy
* Depth +15 of full scale
* (Cylinder Pressure +1“ of fuli scale
» Timers i second per day
Dive Counter
» Displays Dives #1 - #9 then recvcles to #1 (continues to #9)
» Resets to Dive #1, upon diving (after 12 hour surface time}
Dive Log Mode
* Stores 12 most recent dives in memory for viewing
+ After 12 dives, adds 13th dive in memory and deletes the first dive
Altitude
* Operational from sea level to 14,000 feet (4,267 meters) elevation
* Recalibration of depth readings from "feet of sea water" to feet of fresh water
when higher than 2,000 feet (610 meters) elevation
112
Power (Display and Transmitter)
Battery Each - 1 - 3.6 v, 1/2AA, TADIRAN® Lithium
Model TL-2150
Shelf life Up te 10 years
Replacement User replaceable (annual recommended)
Life expectancy 100 dives, or 1 year, whichever comes first
NOTE: Battery life is maximized when batteries are removed from
the 750GT Transmitter and Display Module during long periods of
inactivity.
Activation:
+
+ + » т я
Display Module - manual push button
Transmitter - gas pressure
Cannot be activated by water immersion
Cannot be activated deeper than 4 feet (1.5 m)
Cannot be activated at elevations higher than 14,000 feet (4,267 m)
Needed before first, dive, and after a 12 hour surface interval,
Automatically shuts unit off if dive is made within 120 minutes after
initial activation. Reactivation required.
(Cannot be shut off manually.
750GT
RESPONSIBLE COMPUTER DIVING
Since the advent of dive computers, it is a common mistake to assume that the old traditional rules of diving
no longer apply, but the truth is just the opposite. Before you dive using your 750GT, keep these basic rules in
mind:
* Plan each dive, and dive your plan - Your computer was not designed to make decisions for you, only
to provide you with the information you need to make responsible decisions for yourself. This begins with
a dive plan that will help you avoid a low air or decompression situation.
* Do not plan any dive that exceeds your training or experience level.
* Inspect your computer before every dive - If it shows any signs of damage or abnormal function, DO
NOT dive with it until it has received factory service.
* Make your deepest dive first - When making repetitive dives, it is imperative to ensure that each con-
secutive dive is shallower than the one before. This will allow your body's slower tissues to continue out-
gassing nitrogen.
* Make the deepest part of your dive first, and gradually work your way to the surface using a
“stairease” profile - The ability to perform multilevel diving is one of the most important contributions
of a dive computer, and you should take advantage of it. It will increase your bottom time and at the
same time decrease your risk of decompression sickness.
° Ascend slowly by following an ascent line whenever possible, or by ascending diagonally to-
ward the surface - Watch the Ascent Rate Tindicator closely while you ascend, and keep it in the green
zone as much as possible,
* Make a safety stop at 15-20 feet (4.5-6 m) at the end of every dive - A safety stop of as little as 5
minutes has been shown to have a dramatic effect on the bubble formation in divers. It's important.
Don't forget it.
113
ENGLISH
MODE: FO2
MODE:PLAN
MODE:LOG
MODE:HIST
MODE:SET
SET: TIME
SET:DATE
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
DEC
114
LANGUAGE CROSS REFERENCE
ITALIANO
MODO:FO2
MODO:PIAN
MODO:LOG
MODO:DATI
MODO:REG
REG:ORA
REG:DATA
GEN
FEB
MAR
APR
MAG
GU
LUG
AGO
SET
OTT
NOV
DIC
DEUTSCH
MODE: FO2
MODE: PLAN
MODE:LOG
MODE:DATA
MODE:SET
SE ZETT
SET:DATM
JAN
FEB
MAR
APR
MAI
JUN
JUL
AUG
SEP
OKT
NOV
DEZ
ESPANOL,
MODO:FO2
MODO:PLAN
MODO:BTC
MODO:HIST
MODO:LST
LST:TIEM
LST:DIA
ENE
FEB
MAR
ABR
MAY
JUN
JUL
AGO
SEP
OCT
NOV
DIC
FRANCAIS
MODE:FOZ
MODE:PLAN
MODE:MEM
MODE: HIST
MODE:REG
REG:HEURE
REG:DATE
JAN
FEV
MAR
AVR
MAI
JUIN
JUIL
AOÛ
SEP
OCT
NOV
DEC
ENGLISH
SET:ALT
ALT:ON
ALT: OFF
SET: UNIT
UNITS
SET: ALRM
ALRM:DPTH
ALRM:GAS
ALRM:ON
ALRM:OFF
SET:LINK
SN 999999
SET:LANG
ENGLISH
ITALIANO
DEUTSCH
ESPAÑOL
FRANCAIS
MODE:EACC
EACC 8
LANGUAGE CROSS REFERENCE (continued)
ITALIANO
REG:ALT
ALT:ON
ALT:OFF
REG:UNIT
UNIT'A'
REG:ALRM
ALRM:PROF
ALRM:GAS
ALRM:ON
ALRM:OFF
REG:COLL
SN 999999
REG:LING
ENGLISH
ITALIANO
DEUTSCH
ESPAÑOL
FRANCAIS
MODO:ACCE
ACCE 8
DEUTSCH
SET:ALT
ALT:AN
ALT:AUS
SET:EINH
EINHEITEN
SET: ALRM
AT RM: TIEF
ALRM:LUF
ALRM:AN
ALRM:AUS
SET:KUPP
SN 999999
SET:SPRA
ENGLISH
ITALIANO
DEUTSCH
ESPAÑOL
FRANCAIS
MODE: AUZU
AUZU 8
ESPAÑOL
LST:ALT
ALT:ON
ALT:OFF
LST:UNID
UNIDADES
LST:ALRM
ALRM:PREN
ALRM:GAS
ALRM:ON
ALRM:OFF
LST:CONX
SN 999999
LST:LENG
ENGLISH
ITALIANO
DEUTSCH
ESPAÑOL
FRANCAIS
MODO:ACCE
ACCE 8
750GT
FRANCAIS
REG:ALT
ALT:QUI
ALT:NON
REG:UNIT
UNITES
REG:ALRM
ALRM:PROF
ALRM:GAS
ALRM:OUT
ALRM:NON
LIAISON
NS 999999
REG:LANG
ENGLISH
ITALIANO
DEUTSCH
ESPAÑOL
FRANCAIS
MODE:ORDI
ORDI 8
115
ENGLISH
CEILING
10 FT
3M
SELF-TEST
GAS ALARM
TOO HIGH
TOO FAST
TOO DEEP
VIOLATION
EXCEEDED
FLY
116
LANGUAGE CROSS REFERENCE (continued)
ITALIANO
TAPPAA
10 PIE
3 MET
TEST
GAS ALARM
QUOTA ECC
RALLENTAR
FONDO ECC
VIOLAZ
ECCEDUTO
VOL
DEUTSCH
MIN-TIEFE
10 FT
3 MET
EIGENTEST
LUFTALARM
ZU HOCK
ZU SCHNEL
ZU TIEF
VERSTOSS
VERSTOSS
FLY
ESPAÑOL
MAX NIVEL
10 PIE
3 MET
AUTO EXAM
GAS ALARM
DEM ALTO
DEM RAPID
DEM PREND
VIOLACION
EXCEDIDO
VER
FRANCAIS
PALIER
10 PIE
3 MET
AUTO-TEST
GAS ALARM
ALTITUDE
VITREMONT
PROFOND
VIOLATION
VIOLATION
VOL
750GT
GLOSSARY
The following are diving terms to become familiar with. Some apply specifically to the 750GT.
Air Dive - A dive conducted using air (approximately 21% oxygen € 79% nitrogen) as the breathing gas.
Algorithm - A step-by-step mathematical formula designed to accomplish a particular result (i.e. Dive Time
Remaining in the 750GT).
Altitude Dive - A dive made at an elevation above sea level (2,000+ ft. / 610+ m.) where a different set of no
decompression tables is used .
Ascent Rate Indicator - A display that shows ascent rate as a bar graph alongside a color-coded indicator.
Breathing Gas Time Remaining - A graphic display of remaining dive time based on a calculation of cylinder
pressure, and the diver’s breathing rate and depth.
Ascent Rate - The speed that a diver ascends toward the surface.
Audible Alarm - A computer emitted tone that alerts the diver to potential danger.
Breathing Gas Consumption Indicator - A graphic display of breathing gas consumption rate,
Caution Zone - The yellow sections of the Bar Graphs that give a visual warning of a diver’s proximity to limits.
Ceiling - See decompression ceiling.
Clean Dive - A dive preceded by 24 hours of no diving activity.
CNS - Abbreviation for the Central Nervous System of the body.
Competitive Dive - A dive conducted for profit or prize.
Compartment - A term applied to the hypothetical modeling of nitrogen absorption in the tissues (more accurate
than the term “tissue” because dive computer models have no direct relation to human tissues).
DCS - Abbreviation for decompression sickness, i.e., “the bends”.
117
GLOSSARY (continued)
DECO - Abbreviation for Decompression.
Decompression Ceiling - The shallowest depth a diver may reach upon ascent without risking decompression :
sickness.
Decompression Stop - The depth(s) at which a diver must pause during ascent to allow absorbed nitrogen to -
escape naturally from the tissues.
Depth Sensor - an electro-mechanical device that converts water pressure into an electrical signal, that is
converted to a visual depth display.
Diagnostic Mode - The first display seen on dive computers after initial activation during which time a self-check
for internal faults is performed.
Display - A visual readout of information.
Dive Log Mode - A computer display of previous dive information.
Dive Time Remaining - A display of the time before a diver must surface based on no-decompression status, :
oxygen accumulation status, or tank pressure, |
Elapsed Dive Time - The total time spent underwater during a dive between 5 feet (1.5 meters) on initial
descent to 3 feet (1 meter) on final ascent.
FO2 - The fraction (percent / 100) of oxygen (02) in the breathing gas mixture.
Icon - a small pictorial representation of an operational mode
Integrated Dive Computer - A dive computer that monitors and displays cylinder pressure in addition to no
decompression information.
LCD - Abbreviation for liquid crystal display, an easily viewed low voltage display usually found on dive computers Ш
Maximum Depth - The deepest depth attained during a dive.
118
750GT
GLOSSARY (continued)
Message - An alpha/numeric display that provides various warnings and messages to the diver to better clarify
on-screen information and audible alarm signals.
Mode - À specific set of functions in a dive computer.
Multiplexing Display - À display on an instrument that alternates to show different information relating to
separate events.
Multi-level Dive - A type of dive profile where the diver spends various times at different depths (opposite of a
“Square Wave” dive profile).
Nitrogen Bar Graph - A graphic display of simulated nitrogen absorption on ABRIS dive computers,
Nitrox - A nitrogen-oxygen breathing gas mixture that contains a higher fraction of oxygen than air.
Nitrox Dive - A dive conducted using nitrox (22 to 50 % O2) as the breathing gas.
No Deco - Abbreviation for No Decompression.
No Deco Time Remaining - The amount of dive time remaining based on no-decompression status.
No Decompression - Any part of a dive where the diver can surface without requiring a decompression stop.
O2 Bar Graph - A visual representation of oxygen accumulation on a dive computer display.
OTU - Abbreviation for oxygen tolerance unit. A Hamilton's Repex method term for oxygen dose.
Out of Range - The point at which a dive computer can no longer supply correct dive information.
Oxygen Tolerance - Dose or exposure to the physiological affects of elevated levels of oxygen.
Oxygen Toxicity - The adverse physiological affects of exposure to elevated levels of oxygen.
Partial Pressure - The proportion of the total pressure contributed by a single gas in a mixture of gases.
PO2 - Partial pressure of oxygen. The proportion of total pressure of a gas mixture contributed by oxygen.
119
GLOSSARY (continued)
Plan Sequence - A display of available dive times at 10 foot (3 meter) intervals from 30 to 160 feet (9 to 48 meters)
used when dive planning.
Pressure Sensor - an electro-mechanical device that converts cylinder pressure into an electrical signal that the
750GT converts into cylinder pressure and air time remaining displays.
Repetitive Dive - Any dive that takes place within 12 hours of a previous dive.
Safety Stop - A depth at which a diver may choose, but is not required, to pause during ascent to allow absorbed .
nitrogen to escape naturally from the tissues.
Square Wave Dive - A type of dive profile where the entire dive is spent at one depth between descent and ascent.
Tissue - See Compartment.
Tissue Compartment - See Compartment.
Transducer - An electro-mechanical device in a dive computer that acts as a depth or pressure sensor.
Transition Period - The first 10 minutes of surface time after ascending above 3 feet (1 meter) from a dive.
120
4
RESPONSIBLE DIVER
I UNDERSTAND AND ASSUME
THE RISKS I MAY ENCOUNTER
SPONSIBLE DI 3 HNSY
* DIVING WITHIN THE LIMITS OF MY
ABILITY AND TRAINING
EVALUATING THE CONDITIONS
BEFORE EVERY DIVE AND MAKING
SURE THEY FIT MY PERSONAL
CAPABILITIES
BEING FAMILIAR WITH AND
CHECKING MY EQUIPMENT BE.
FORE AND DURING EVERY DIVE
ENOWING MY BUDDY'S ABILITY
LEVEL AS WELL AS MY OWN
ACCEPTING THE RESPONSIBILITY
FOR MY OWN SAFETY ON EVERY
DIVE
N
THE CODE OF THE
AS A RESPONSIBLE DIVER
WHILE DIVING.
7
750GT
750GT SERVICE RECORD
Serial Number
Date of purchase
Purchased from
Below to be filled in by an Authorized AERIS Dealer:
Date Service Performed Dealer / Technician
121

advertisement

Key Features

  • Real-time dive data monitoring
  • Depth and time displays
  • Breathing gas pressure monitoring
  • Air consumption monitoring
  • Ascent rate monitoring
  • Nitrogen and oxygen accumulation tracking
  • Dive planning and decompression calculations

Related manuals

Frequently Answers and Questions

How long is the warranty period?
2 Years
Does the device have an audible alarm?
Yes
What is the operating temperature range?
32°F to 122°F (0°C to 50°C)
Can I share the device with other divers?
Yes

advertisement