Excell FAP3 Price Computing Bench Scale User Manual

Add to My manuals
14 Pages

advertisement

Excell FAP3 Price Computing Bench Scale User Manual | Manualzz

Price Computing

Scale

User Manual

©EXCELL PRECISION CO., LTD. 2014. All Rights Reserved Worldwide.

The information contained herein is the property of EXCELL PRECISION CO., LTD. and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.

EXCELL PRECISION CO., LTD

Table of Contents

INSTRUCTIONS FOR USE ......................................................................................................... 2

PREPARING TO USE THE SCALE ............................................................................................. 2

CHAPTER 1 KEYPAD DESCRIPTION ........................................................................................ 4

CHAPTER 2 BACKLIGHT SETTING ........................................................................................... 6

CHAPTER 3 FIXED PRICE UNIT ................................................................................................ 7

CHAPTER 4 FUNCTION SETTINGS........................................................................................... 8

4-1 F0

P

ROGRAM

V

ERSION

...................................................................................................... 9

4-2 F6

C

URRENCY

S

ELECTION

................................................................................................ 9

4-3 F9

G V

ALUE

C

ALIBRATION

............................................................................................... 10

4-4 F10

RS-232 T

RANSMISSION

S

ETTING

(

OPTION

)................................................................ 11

CHAPTER 5 ERROR MESSAGES ............................................................................................ 11

APPENDIX 1 7-SEGMENT DISPLAY CHARACTERS............................................................... 12

01008044

1

ZSME100000124

EXCELL PRECISION CO., LTD

Thank you for purchasing EXCELL Price

Computing Scale. In order to operate smoothly, to last the durability and to reduce chance of breakdown for this product, please read this manual carefully.

Instructions for Use

1. Please cover the scale with dustproof cover when not in use to prevent possible damage from dust and static electricity.

2. Washing with rain or water is prohibited. (If gets wet accidentally, please wipe it dry with cloth. When the scale does not work properly, please return it to our distributor for service.)

3. Please keep the scale in a cool and dry place. Do not store at high temperature or damp places.

4. Please keep the scale clean and away from insects entering the scale.

5. Avoid heavy impact or overloading. (When over its maximum capacity, it might damage the scale)

6. When the scale is not in use for some time, please clean and wrap the scale well.

Recommend to store with desiccators and to recharge battery every 3 months or before use.

7. For an accurate reading, please place objects near the center of the platter and within the platter.

8. Please operate or charge the scale in an open area. Do not squeeze the power cord to avoid wire on fire.

9. Operating temperature: -10

~ + 40

10. Any suggestion for product is warmly welcome.

Preparing to Use the Scale

1. Please locate the precision scale on a stable, flat desk and don’t put it on a shaking or unstable desk. Adjust the four leveling feet to make the scale horizontal. Make sure that the bubble level is in the center of the circle.

2. Keep the scale away from places with strong drafts or excessive temperature fluctuations

(E.g. from direct sunlight or the air louver of an air conditioner).

3. Please use an independent power outlet to avoid interruption by other electrical appliances.

4. Don’t put any object on the scale while switching on the scale.

5. Please keep the scale switched on for 15 ~ 20 minutes before operation.

6. When the low battery indicator appears in the right corner of the display, replace the dry batteries or charge the battery.

7. Introduction of Storage Battery:

2

01008044

ZSME100000124

EXCELL PRECISION CO., LTD

Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte.

The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery.

1. The battery should be charged for 8~10 hours.

2. The temperature of battery should below 45

.

Maintaining

1. Please do not discharge with over-current when using the battery. Please charge the battery after discharging current.

2. Please take down the battery when the scale is not used for a long time or break the connection of cathode.

3. Do not short the battery terminals to check whether there is current. Please check whether the connection point is firm to guarantee good connection.

4. The battery should be replaced by specialized person.

No reverse-battery or the product will be damaged.

a) Anode of battery should be connected with Anode of product battery

( usually red cable

) b) Cathode of battery should be connected with Cathode of product battery (usually brown cable or black cable) c) See the picture following

Brown cable(or black cable) connected with Anode of battery

Red cable connected with

Cathode of battery

Safety warnings

1. The electrolyte of battery is caustic which causes metal, cotton, etc to corrode.

2. The hydrogen will be resolved when using or charging the battery and it will cause explosion when approaches fire.

No burning Caution Corrosion

Warning explosion

Children faraway

01008044

3

ZSME100000124

EXCELL PRECISION CO., LTD

Chapter 1 Keypad Description

~

Number key. Press the keys to input the numbers (0 ~ 9).

Press the key once to enter a double zero “00”

Clear Key. Press the key to clear the unit price.

or

or

or

For 18 keys:

01008044

Clear Key. Press the key to clear the last digit of unit price.

Zero key. Press the key to rezero the scale, and the zero range is

±

2

% of full capacity.

Tare key.

Press the key once to deduct the container weight. And the tare indication “

3

” is displayed in the WEIGHT. When the objects are removed from the platter, WEIGHT will display a negative value.

In the FIX mode, press the key once again to exit the Tare Function and the tare indication “

3

” goes off.

If the weight value is negative and the tare is not enable then press the key to zero the scale.

Multi-tare function: A negative tare value is not allowed. The tare range could extend to 4 digits.

Confirm key.

Shift key. (Euro / NC).

Key in unit price in pricing mode, the TOTAL PRICE displays the

Total price of them.

Press this key again, the TOTAL PRICE displays the converted total price; the UNIT PRICE will display the NC (national currency) symbol.

Press the key, and press the 1 key to select price unit “kg”.

Press the key, and press the 2 key to select price unit “100g”.

The indication “

3

” will be displayed on the UNIT PRICE.

4

ZSME100000124

EXCELL PRECISION CO., LTD

For 17 keys:

Shifted the FIX unit price mode (on / off).

FIX mode off

FIX indication “

3

” goes off in TOTAL PRICE

I Weight is at zero, the unit price will be automatically cleared after 3 seconds.

II In the taring mode, after the object is removed from the platter, the tare value will be cleared automatically.

FIX mode on

FIX indication “

3

” sign is on in TOTAL PRICE

I Weight is at zero or at any weight, press key to clear the unit price.

II In the taring mode, after the object is removed from the platter, the WEIGHT will display the negative value,

press key to clear the tare value.

Shift unit key

Shifted the PREPACK mode (on / off).

PREPACK mode off

PREPACK indication “

3

” goes off in

TOTAL PRICE

I Weight is at zero, the unit price will be automatically cleared after 3 seconds.

II In the taring mode, after the object is removed from the platter, the tare value will be cleared automatically.

PREPACK mode on

PREPACK indication “

3

” sign is on in

TOTAL PRICE

I Weight is at zero or at any weight, press key to clear the unit price.

II In the taring mode, after the object is removed from the platter, the WEIGHT will display the negative value,

press key to clear the tare value.

18keys

7 8 9

4 5 6 kg

100g

NCU

17keys

7 8 9

4 5 6

Í

0 00 FIX

0

T

0 00

PACK

Z

T

5

01008044

ZSME100000124

EXCELL PRECISION CO., LTD

Chapter 2 Backlight Setting

METHOD I

Press the key ( for 17key model) first, and then press the key before the” ” in the WEIGHT window disappears. Thus the “auto backlight” function is activated.

Press the key ( for 17key model) first, and then press the key before the” ” in the WEIGHT window disappears, Thus the “No Backlight” function is selected.

METHOD II

Hold the key for 2 seconds, and the buzzer beeps for three times. In this way the backlight mode is shifted between “Auto Backlight” and “No Backlight”.

The scale will memorize the current backlight mode when it is switched off, and will be the same mode when switched on in the next time.

01008044

6

ZSME100000124

EXCELL PRECISION CO., LTD

Chapter 3 Fixed Price Unit

Setting procedures

Use the key ( for 17key models) to select the desired price unit. Press the key ( for 17key model) first and press the key when the display shows”

” in the WEIGHT window. The selected price unit will be shown when switching on in the next time.

After the above setting, no matter what unit will be used in pricing or any other unit is in use before shutting down, the fixed price unit will still be shown when restarting the scale.

Cancel procedures

Press the key ( for 17key models) first and then press the key when the display shows” ” in the WEIGHT window to cancel the previous fixed price unit.

After canceling the fixed unit price, the scale will memorize the current price unit when it is switched off, and will be the same unit when switched on in the next time.

To change the fixed price unit, take the next 4 steps as following.

1. Enter the previous fixed price unit mode.

2. Cancel the fixed price unit.

3. Enter the new price unit.

4. Fix this price unit.

01008044

7

ZSME100000124

EXCELL PRECISION CO., LTD

Chapter 4 Function Settings

Press and hold key until the scale enters into the function setting mode while the scale is counting down to zero.

Press key in order, the WEIGHT column will display F0 ~ F9 in sequence.

Press

Press

Press

Press

Press

Press

Press

Press

Press

Press

Press

key

key

key

key

key

key

key

key

key

key

key

Program version No.

Reserved

Reserved

Reserved

Reserved

Reserved

Select base currency

Reserved

Reserved

G value calibration

RS-232 Transmission Setting

8

01008044

ZSME100000124

EXCELL PRECISION CO., LTD

4-1 F0

Program Version

WEIGHT UNIT PRICE

Program Version

Press key to go to the next function.

TOTAL PRICE

4-2 F6

Currency Selection

WEIGHT UNIT PRICE TOTAL PRICE

Press key

WEIGHT UNIT PRICE TOTAL PRICE

Press key

Previous value

WEIGHT

UNIT PRICE

TOTAL PRICE

Press key

WEIGHT UNIT PRICE TOTAL PRICE

Press key

WEIGHT UNIT PRICE TOTAL PRICE

Press key

Press the key to confirm, the setting procedure is completed.

To give up the setting, press the key to exit the setting mode.

National currency selection

European currency selection

01008044

9

ZSME100000124

EXCELL PRECISION CO., LTD

4-3 F9

G Value Calibration

1. Please set the G value as the local one. The counter is auto-add once when the setting procedure is completed.

2. The counter is set up to the ninth times.

WEIGHT UNIT PRICE TOTAL PRICE

Press key to enter into check historical data mode. Press key to show the historical value in sequence.

WEIGHT UNIT PRICE

n

TOTAL PRICE

.

Display the last G value.

WEIGHT UNIT PRICE

n-1

TOTAL PRICE

.

Display the last 2 G value.

WEIGHT UNIT PRICE TOTAL PRICE

.

Display the original manufacture G value.

Press key to enter into G value setting mode. To abort the setting, press the key to exit the setting mode.

WEIGHT UNIT PRICE

n+1

Counter +1

TOTAL PRICE

.

Press ~ to input G value.

Press the key to confirm, the setting procedure is completed.

To abort the setting, press the key to exit the setting mode.

The G value is range from 9.83217 to 9.78031

01008044

10

ZSME100000124

EXCELL PRECISION CO., LTD

4-4 F10

RS-232 Transmission Setting (option)

WEIGHT UNIT PRICE TOTAL PRICE

Press key

WEIGHT UNIT PRICE TOTAL PRICE

X

previous value

Press key to select 1 (open) or 0 (close)

Press the key to confirm, the setting procedure is completed.

To give up the setting, press the to exit the setting mode.

Default transmit rate: 9600 N81

Select 1 to open RS232, then the print format is as followed:

N 10.000Kg

T 0.500Kg

U/P 50/Kg

Select 0 to close the RS232.

Chapter 5 Error Messages

ZERO value is higher than +10% F.S.

ZERO value is lower than - 10% F.S.

ZERO value is higher than 350 000 when calibrating.

ZERO value is lower than 80 000 when calibrating.

The weight is higher than 9 division of maximum capacity

- - - - -

If the negative weight is over 20 divisions and there is no tare weight or pre-tare weight, the display shows “- - - - - -”

11

01008044

ZSME100000124

EXCELL PRECISION CO., LTD

Appendix 1 7-Segment Display Characters

Number Display Letter Display Letter Display

0 A N

1 B O

2 C P

3 D Q

4 E R

5 F S

6 G T

7 H U

8 I V

9 J W

K X

L Y

01008044

M

12

Z

ZSME100000124

advertisement

Key Features

  • Accurate and reliable weighing up to 15kg
  • Easy-to-use keypad with large, clear buttons
  • Bright backlit display for easy reading in all lighting conditions
  • Fixed price unit for quick and easy pricing
  • Multiple currency selection for international use
  • RS-232 transmission for connectivity with other devices
  • Rechargeable battery for portable use

Related manuals

Frequently Answers and Questions

How do I set the unit price on the Excell FAP3?
To set the unit price, simply press the number keys to enter the desired price. You can use the or keys to clear the last digit of the unit price, or the key to clear the entire unit price.
How do I change the currency on the Excell FAP3?
To change the currency, press the F6 key and use the number keys to select the desired currency from the list of available currencies.
How do I calibrate the Excell FAP3?
To calibrate the Excell FAP3, press the F9 key and follow the on-screen instructions.
How do I connect the Excell FAP3 to a computer?
To connect the Excell FAP3 to a computer, use a RS-232 cable to connect the scale to the computer's serial port.
How do I charge the battery on the Excell FAP3?
To charge the battery on the Excell FAP3, connect the scale to a power outlet using the included power adapter.
Download PDF

advertisement