Excell FTCH3 High Resolution Counting Bench Scale User Manual

Add to My manuals
47 Pages

advertisement

Excell FTCH3 High Resolution Counting Bench Scale User Manual | Manualzz

H3 Series

Counting Scale

User Manual

© EXCELL PRECISION CO., LTD. 2015. All rights reserved worldwide.

The information contained herein is the property of EXCELL PRECISION CO., LTD. and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.

EXCELL PRECISION CO., LTD.

Table of Contents

Instruction for Use ........................................................................................................................ 3

Preparations before Using ........................................................................................................... 3

Chapter 1 Display and Keypad Descriptions................................................................................ 5

1-1 Display Descriptions........................................................................................................... 5

1-2 Keypad Descriptions .......................................................................................................... 6

1-3 Error Messages .................................................................................................................. 7

1-4 Self-Test Mode ................................................................................................................... 8

1-4-1 Check Software Version Number ................................................ 9

1-4-2 Check Key and LCD

BL Test .................................................. 9

1-4-3 Read AD Value ........................................................................... 9

1-4-4 Keypad Test Code .................................................................... 10

1-4-5 EEPROM

Switch Calibration Test .......................................... 11

1-4-6 Real Time Clock (RTC) ............................................................. 11

1-4-7 RS-232 ..................................................................................... 12

1-4-8 Read free format PCB Software Version Number ..................... 12

1-4-9 Read Temperature IC AD Value ................................................ 12

1-4-10 Read Battery AD Value ........................................................... 13

1-4-11 ESC (leave test mode) ............................................................ 13

Chapter 2 Operation .................................................................................................................. 14

2-1 Power On ......................................................................................................................... 14

2-2 Relatively Internal Value Display ...................................................................................... 14

2-3 Zero Function ................................................................................................................... 14

2-4 Sampling Function............................................................................................................ 14

2-4-1 Unknown Unit Weight of a Weighed Object............................................................... 14

2-4-2 Known Unit Weight of a Weighed Object................................................................... 15

2-4-3 Under Tare Status ...................................................................................................... 15

2-5 Tare Function Operation ................................................................................................... 15

2-6 Pre-tare Function Operation ............................................................................................. 16

2-7 Accumulation .................................................................................................................... 17

2-7-1 Quantity Accumulation ............................................................................................... 17

2-7-2 Weight Accumulation ................................................................................................. 18

2-8 Quantity Preset................................................................................................................. 18

2-9 Weight Preset................................................................................................................... 19

2-10 ID Input........................................................................................................................... 20

2-11 Item Input........................................................................................................................ 20

2-12 Unit Weight Preset ......................................................................................................... 21

03004035 1 ZSME200000054

EXCELL PRECISION CO., LTD.

Chapter 3 External Calibration Setting ....................................................................................... 22

3-1 External Function Setting ................................................................. 22

3-1-1 Backlight Mode Setting .............................................................. 23

3-1-2 Auto. Power-off Setting .............................................................. 23

3-1-3 Stable Range Setting for Quantity Sampling ............................. 24

3-1-4 Auto. Average Unit Weight Setting ............................................ 24

3-1-5 A/D Sampling Speed Setting ..................................................... 25

3-1-6 Zero Display Range Setting ...................................................... 25

3-1-7 Zero Tracking Range Setting ..................................................... 26

3-1-8 Accumulation Ending Mode Setting ........................................... 26

3-1-9 Pre-tare mode setting ................................................................ 27

3-1-10 “Beeper” Output Setting for Quantity Limit ................................ 27

3-1-11 Accumulation Acceptable Condition Setting 1 ............................. 28

3-1-12 Accumulation Acceptable Condition Setting 2 ........................... 28

3-1-13 Combination Key Setting ............................................................. 29

3-2 External Weight and G Value Calibration .............................................. 30

3-2-1 External Weight Calibration .............................................................. 31

3-2-2 Calibrate G Value Used in Local or in Verification ............................ 32

3-3 RS-232 and Serial Printer Setting ................................................... 34

3-3-1 Baud Rate Setting .................................................................... 34

3-3-2 Communication Protocol Setting .............................................. 35

3-3-3 Output Data Format Setting ...................................................... 35

3-3-4 Output Count Setting Per-second ............................................. 37

3-3-5 Operation Mode Setting ............................................................ 37

3-3-6 Continuous Transmission Output Condition Setting ................. 39

3-3-7 Zero Band Setting for Auto. Transmission ................................ 40

3-3-8 Weight Band Setting for Auto. Transmission ............................ 40

Appendix 1 RS-232 Full Duplex Format..................................................................................... 41

Appendix 2 Fixed Format RS-232 Transmission Line Description ............................................. 43

Appendix 3 ASCII Code Table .................................................................................................... 44

Appendix 4 7-Segment Display Characters ............................................................................... 45

03004035 2 ZSME200000054

EXCELL PRECISION CO., LTD.

Thank you for purchasing EXCELL counting scale.

In order to operate smoothly, to last the durability and to reduce chance of breakdown for this product,

Please read this manual carefully.

Instruction for Use

1. The scale should not be drenched by rain or water. (If it gets wet carelessly, please wipe it dry with a cloth. If its operation is abnormal, please send it to our distributor for service)

2. Please keep the scale in a cool and dry place. Do not store at high temperature or damp places.

3. Please keep the scale clean and free from insect infestation.

4. To avoid impact and it is to be used under designated pressure (the weight put on the platter can not exceed the maximum capacity of the scale)

5. If the scale is not going to be used for some time, please clean in and store it in a plastic bag with desiccative. The internal rechargeable battery should be recharged every three months. (If using dry batteries, take the dry batteries out before storing)

6. The commodity should be placed in the center of platter for accurate weighing. The dimension of the weighted commodity should not exceed the dimension of platter.

7. In order to maintain the re-chargeable battery in good condition it should be kept fully charged whenever possible. If the scale is to be stored, the battery should be fully charged before storage, and then re-charged at 3 month intervals. The number of times that the battery can be recharged will vary according to the conditions of use. However it can be maximized by re-charging the battery frequently and by avoiding conditions of total discharge. The battery cannot be overcharged.

8. Please operate or charge the scale in an open area. Do not squeeze the power cord to avoid wire on fire. temperature: -10 ~ +40

10. Any suggestion for the product is warmly welcome.

Preparations before Using

1. Put the scale on a firm and flat surface for accurate weighing reading. Adjust the four leveling feet to get the leveling bubble at the center of the circle.

2. Scale must be used under a stable temperature and stable air flow. Avoid direct sunlight onto the scale or near the air-conditioning outlet.

3. Scale must be used under individual socket to avoid the interference of other electric appliances.

4. Remove any weight that might be on the platter before the scale is switched on.

5. The scale requires 15 ~ 20 minutes warm up before operation to ensure best accuracy.

6. When symbol appears on the screen, the internal battery needs to be replaced.

7. Introduction of Storage Battery

03004035 3 ZSME200000054

EXCELL PRECISION CO., LTD.

Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte.

The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery.

1. The battery should be charged for 8~10 hours.

2. The temperature of battery should below 45

.

Maintaining

1. Please do not discharge with over-current when using the battery. Please charge the battery after discharging current.

2. Please take down the battery when the scale is not used for a long time or break the connection of cathode.

3. Do not short the battery terminals to check whether there is current. Please check whether the connection point is firm to guarantee good connection.

4. The battery should be replaced by specialized person.

No reverse-battery or the product will be damaged.

a) Anode of battery should be connected with Anode of product battery

( usually red cable

) b) Cathode of battery should be connected with Cathode of product battery (usually brown cable or black cable) c) See the picture following

Brown cable(or black cable) connected with Cathode of battery

Red cable connected with

Anode of battery

Safety warnings

1. The electrolyte of battery is caustic which causes metal, cotton, etc to corrode.

2. The hydrogen will be resolved when using or charging the battery and it will cause explosion when approaches fire.

No burning

Caution Corrosion Warning explosion Children faraway

03004035 4 ZSME200000054

EXCELL PRECISION CO., LTD.

Chapter 1 Display and Keypad Descriptions

1-1 Display Descriptions o

_

_

.

.

.

.

.

Display Column

_

_

.

.

.

.

.

.

+

_ stable _

.

.

.

.

.

.

1. WEIGHT

Total 6 digits. To display the weight on platter or the total accumulation weight; the left digit is able to display the negative symbol.

2. UNIT WEIGHT

Total 6 digits. To display the unit weight of objects on the platter or total accumulation counts.

3. QUANTITY

Total 6 digits. To display the quantity of the objects on platter or the accumulation.

Symbol Icons “

3

1. or Net or Tare

:

“Tare” indication

2. o or Zero

:

“Zero” indication

3. + or M+

:

“Accumulation” indication

4. Stable

:

“Stable” indication

5.

:

If the weight of the sample is less than the weight of the minimum sample, this symbol will display. Please add the number of sample then sampling.

Minimum unit weight is 0.1d with resolution equal to 1/3000.

Minimum unit weight is 0.2d with resolution range from 1/6000 to 1/30000.

If symbol displays, scale may cause some counting error even if the scale can still be used.

6.

:

If the unit weight of the object on the platter is less than “Minimum Unit Weight”, this symbol will display. The scale can still count the quantity even though the unit weight is too small; however, this may affect the counting inaccuracy.

Please use the scale which the division and specification are both subject to.

If symbol displays, scale may cause some counting error even if the scale can still be used.

Minimum unit weight is 0.1d with resolution equal to 1/3000. (d=division)

Minimum unit weight is 0.2d with resolution range from 1/6,000 to 1/3, 0000.

7.

:

When the symbol displays, the battery need to be recharged for safe use.

03004035 5 ZSME200000054

EXCELL PRECISION CO., LTD.

1-2 Keypad Descriptions

[Standard keypad]

7

9

4

GHI

1

PQRS

8

ABC

5

JKL

2

TUV

9

DEF

6

MNO

3

WXYZ

0

.

SAMPL

UNIT

W.T

Q’TY

PST

PST

CE

Z M+

CE T MC

[Double weighing units keypad]

7

9

4

GHI

1

PQRS

8

ABC

5

JKL

2

TUV

9

DEF

6

MNO

3

WXYZ

SAMPL

UNIT

W.T

Q’TY

PST kg/lb

Z M+

0

.

CE T MC

[10 sets of preset unit weight keypad]

7

9

4

GHI

1

PQRS

8

ABC

5

JKL

2

TUV

9

DEF

6

MNO

3

WXYZ

SAMPL

UNIT

W.T

Q’TY

PST

U.W

PST

Z M+

CE T MC 0

.

Key Function

, ~

:

Number key for setting the unit weight, quantity and etc.

:

Clear key to clear the digits on the display.

:

Unit weight key for setting the unit weight of sample.

:

Press this key, the display returns to 0.

:

Press this key to deduct the weight of container. Or shift the digit pointer to left.

03004035 6 ZSME200000054

EXCELL PRECISION CO., LTD.

:

Pre-setting the upper limit of count. If the calculated count is larger than the limit, the scale sends a warning sound. Or use this key to confirm the setting.

:

Totalizing the quantity or weight.

:

Clear the stored totalizing memory. Or shift the digit pointer to right.

Different keys for different models:

:

Press this key to clear preset.

:

Press this key to switch the unit : kg or lb

:

Press this key to preset the unit weight of sample. Or use this key to enter the setting mode.

1-3 Error Messages

zero value is too high

zero value is too low

Internal value

700,000 (use in factory calibration)

Internal value

100,000 (use in factory calibration)

The weight value is over 9d of the maximum capacity. (d = division)

Internal value is unstable (Unstable time is over 10 seconds after pressing

ZERO

or

TARE

key)

03004035 7 ZSME200000054

EXCELL PRECISION CO., LTD.

1-4 Self-Test Mode

Hold

ZERO key to turn on the scale until the display show “

Shows” ” to enter “Self- Test Mode”.

”. Wait till display

Press

Press

Press

Press

Press

Press

TARE

TARE

TARE

TARE

TARE

TARE

key key key key key key

Check Software version number

Check key and LCD

BL test

Read AD value

Key test code

EEPROM

、 switch calibration test

Real Time Clock (RTC)

RS-232

Read free format PCB Software version number

Read temperature IC AD value

Read AD value

ESC (leave test mode)

Press

TARE

key

Press

TARE

key

1

1

1 x

1

CE

Move cursor leftward

1

TARE

Exit

Move cursor rightward

MC

Enter

Press

Press

TARE

TARE

key key

03004035 8 ZSME200000054

EXCELL PRECISION CO., LTD.

1-4-1 Check Software Version Number

Press

MC

key

Press

MC

key

03004010 is software version number

Press x key

Show the maintenance number 035 for 1 second then return to 010

1-4-2 Check Key and LCD

BL Test

Press

MC

key

Press x key

The number of LCD is count backward as 9~0 pattern The symbol and backlight of LCD is on when it is odd number,conversly it is off.

1-4-3 Read AD Value

Press

MC

key

X X X X X X X

Press x key Internal value

Check if the internal value is within its normal range

(Idler range: 100,000~700,000)

1 x

1

Exit

1

CE

Move cursor leftward

Internal value

700,000 (S+, S- about +5 mV)

Internal value

100,000 (S+, S- about -1.3 mV) 1

TARE

Move cursor rightward

1

MC

Enter

03004035 9 ZSME200000054

EXCELL PRECISION CO., LTD.

1-4-4 Keypad Test Code

Press

Press

MC

x key key

X X

Internal test code

Keypad

Keypad internal test code

7

9

4

GHI

1

PQRS

8

ABC

5

JKL

2

TUV

9

DEF

6

MNO

3

WXYZ

SAMPL

Q’TY

PST

UNIT

W.T

PST

CE

Z M+

1

1 x

1

1

CE

Move cursor leftward

TARE

Move cursor rightward

1

MC

Exit

Enter

00 10 20 30 40

03 13 23 33 43

0

.

CE T MC 02 ESC 22 32 42

7

9

4

GHI

1

PQRS

0

8

ABC

5

JKL

2

TUV

.

9

DEF

6

MNO

3

WXYZ

SAMPL

Q’TY

PST

UNIT

W.T kg/lb

Z M+

CE T MC

00 10 20 30 40

03 13 23 33 43

02 ESC 22 32 42

7

9

4

GHI

1

PQRS

8

ABC

5

JKL

2

TUV

9

DEF

6

MNO

3

WXYZ

SAMPL

Q’TY

PST

UNIT

W.T

U.W

PST

Z M+

00 10 20 30 40

03 13 23 33 43

0

.

CE T MC 02 ESC 22 32 42

03004035 10 ZSME200000054

EXCELL PRECISION CO., LTD.

1-4-5 EEPROM

Switch Calibration Test

Press

MC

key

Press x key

EEPORM switch test

SWA1 switch test

0: ADJ

1: LOCK

EEPROM reading and writing test

P 1: EEPROM reading and writing is successful

F 1: EEPROM reading and writing fail

(EEPROM is uninstalled or damaged)

1-4-6 Real Time Clock (RTC)

Press

MC

key

Press x key

2005/08/18

08:38:18

12 code numbers standard for: year, month, day, hour, minute, second

The display shows 12 zeros and not flicker, which means free format PCB is not been connected to the main board or free format PCB RTC has not been installed.

To use number key to set the date and time of RTC, then Press x key to finish setting.

1

1 x

1

1

CE

Exit

Move cursor leftward

TARE

Move cursor rightward

1

MC

Enter

03004035 11 ZSME200000054

EXCELL PRECISION CO., LTD.

1-4-7 RS-232

Press

MC

key

Press x key PASS RS-232 the operation of internal board is correct

FAIL RS-232 the operation of internal board fail or not circuit

The test can only test whether the transmission and reception operates regularly in internal software.

1-4-8 Read free format PCB Software Version Number

Press

MC

key

Press x key

X X X X X X X X X

Software number of free format PCB

The main board transmit “T”+0DH+0AH (ASCII) 3 byte to free format card to read the version number of free format PCB shows on LCD

If free format PCB is not been connected or there is something with free format PCB, it will show FAIL.

1-4-9 Read Temperature IC AD Value

Press

MC

key

Press x key Show IC AD value of temperature

If shows “NOTMP”

no temperature IC

03004035 12 ZSME200000054

EXCELL PRECISION CO., LTD.

1-4-10 Read Battery AD Value

Press

MC

key

Press x key AD value of volt

If AD value of volt is less than 398, it will show (about 5.8 V)

1-4-11 ESC (leave test mode)

Press

MC

to restart the scale

.

key

1

1 x

1

1

CE

Exit

Move cursor leftward

TARE

Move cursor rightward

1

MC

Enter

03004035 13 ZSME200000054

EXCELL PRECISION CO., LTD.

Chapter 2 Operation

2-1 Power On

SW switch on (Press SW to location “

”)

WEIGHT UNIT

After stable, the scale will count back to zero.

WEIGHT UNIT

600

Maximum countable data: 600 000 Sampling Speed

After return to zero and being stable, scale will enter into counting mode.

2-2 Relatively Internal Value Display

After press

ZERO

key, screen will show “ - - - - - - ”. Press

CE

key.

WEIGHT UNIT

X X X X X X X X X X X X

Max internal calibration SP value is 5 digits Max internal value is 7 digits.

Press

0

key to return to the counting mode.

2-3 Zero Function

While operating the scale, zero may sometimes fluctuate. (Slight weight changes happen in weight column.) Press

ZERO

key to return to zero.

2-4 Sampling Function

2-4-1 Unknown Unit Weight of a Weighed Object

1. Place the sampling object on platter

.

Weight on platter

2. Enter the quantity of the sample on platter

.

Ñ Ò

Weight on platter Enter the sampling quantity

The number of quantity column will flash 6 seconds. If the user doesn

’ t press the

SAMPLE

key before flashing is over, the scale will complete the unit weight setting procedure automatically after flashing. The scale will also take the number that inputted in unit weight column as the unit weight of object to calculate the quantity of object shown in quantity column.

3. Press

SAMPLE

key while total column number is flashing

.

Weight on platter

03004035 14 ZSME200000054

EXCELL PRECISION CO., LTD.

4. After stable, the scale finishes sampling and enters into counting mode

.

.

stable _

Weight on platter Unit weight of object Enter sampling quantity

2-4-2 Known Unit Weight of a Weighed Object

1. Enter known unit weight of object intended to weigh

o

_

.

.

stable _

Ñ

Unit weight of object intended to weigh

2. Press

UNIT WEIGHT

key to complete setting and enter into counting mode

Ò

o

_

.

.

stable _

Unit weight of object intended to weigh

2-4-3 Under Tare Status

1. Take the sample off the platter

.

The weight of object on platter

2. Input the quantity of sample on the platter

.

The weight of object on platter Enter the quantity of sample

Ñ Ò

The number of quantity column will flash 6 seconds. If the user doesn ’ t press the

SAMPLE

key before flashing is over, the scale will complete the unit weight setting procedure automatically after flashing. The scale will also take the number that inputted in unit weight column as the unit weight of object to calculate the quantity of object shown in quantity column.

3. Press

SAMPLE

key while the number of quantity is flashing

.

Weight of the object on platter

4. After stable, the scale finishes sampling and enters into counting mode

.

.

stable _

Weight of the object on platter Unit weight of object quantity of sample entered

The larger quantity of sampling, the more precise unit weight counted out.

When unit weight column and total quantity column both indicate 0, please press

1 UNIT WEIGHT

key, and the previous unit weight value will come out.

Use

+

and

7 keys to decide whether to display negative weight or not.

2-5 Tare Function Operation

1. Place the packaging container on platter

.

Weight of packaging container

03004035 15 ZSME200000054

EXCELL PRECISION CO., LTD.

2. Press

TARE

key

3. The scale will enter into counting mode after stable

o

_

_

.

Clear off the tare value

stable _

Mode 1: After removing the object together with packaging container, weight column will display the negative value of packaging container. Press

TARE

key again to cancel the tare, and return to zero. The tare symbol “

_

” will disappear.

Mode 2: After removing the object together with packaging container, weight column will display the negative value of packaging container. Press

ZERO

key again to cancel the tare, and return to zero. The tare symbol “

_

” will disappear.

2-6 Pre-tare Function Operation

(Pre-tare setting) is set up as . (No weight on platter)

1. No weight on platter

o

_

.

stable _

2. Press

TARE

key

o

_

.

3. Enter the known weight of packaging container

o

_

_

4. Press

TARE

key

.

weight of packaging container entered

_

.

_

(Pre-tare setting) is set up as

1. Object placed on platter stable _ stable _ stable _

. (Weight on platter)

.

.

stable _

Weight of the object on platter Unit weight of the object Quantity of the object

2. Enter the known weight of packaging container

.

.

stable _

Weight of packaging container entered

Ñ Ò

3. Press

TARE

key

_

.

_

.

stable _

Weight of the object without container Unit weight of the object Quantity without packaging container

03004035 16 ZSME200000054

EXCELL PRECISION CO., LTD.

Pre-tare function is also available if the object has been tarred.

If the net weight on platter is more than zero weight, the tare function is available. Otherwise, it’s not capable of tare function.

Clear off Pre-tare value

After removing the object together with packaging container, weight column will display the negative weight value of the packaging container. Press

TARE

key once again to cancel the pre-tare value and return to zero. Then the tare and pre-tare symbol “ _ ” will disappear.

Recall Pre-tare value

1. Press

Q’TY PRSET

key, and then press

TARE

key

_

.

_ stable _

Pre-tare value

2. After displays pre-tare value about 5 seconds, it automatically returns to the weighing mode

_

.

_

.

stable _

Recall pre-tare value function and clear function are not available for

Standard keypad models

.

2-7 Accumulation

The accumulation counts are up to 99 counts, but the total quantity column is at most 6 digits.

Users can not do positive accumulation and negative accumulation at the same time.

2-7-1 Quantity Accumulation

1. Place an object on platter

.

.

stable _

Weight of the object on platter Unit weight of the object Quantity of the object on platter

2. Press

M+

key

3. After scale is stable

.

+

_ stable _

Accumulated total weight Accumulated total counts Accumulated total quantity

4. After about 3 seconds, scale returns to counting mode

.

.

+

_ stable _

Weight of the object on platter Unit weight of the object Quantity of the object on platter

Recall quantity accumulation

While weight column displays 0, press

M+

key to recall the accumulated data

o

_

.

+

_ stable _

Accumulated total weight Accumulated total counts Accumulated total quantity

03004035 17 ZSME200000054

EXCELL PRECISION CO., LTD.

Clear off the accumulated quantity value

Press

MC

key to clear off the accumulated value in the memory, and then accumulation symbol “

_

” will disappear.

2-7-2 Weight Accumulation

1. Place an object on platter when unit weight displays 0

2. Press

M+

key

.

Weight of the object on platter stable _

3. After scale is stable

.

+

_ stable _

Accumulated total weight Accumulated total counts

4. After about 3 seconds, scale returns to weighing mode

.

Weight of the object on platter

Recall weight accumulation value

+

_ stable _

While weight column displays 0, press

M+

key to recall the accumulated data

o

_

.

+

_ stable _

Accumulated total weight Accumulated total counts

Clear off the accumulated weight value

Press

MC

key to clear off the accumulated weight in the memory, and then the accumulation symbol “ _ ” will disappear.

2-8 Quantity Preset

It’s available to pre-set the upper limit of quantity in counting mode. If the counts are over the limit, the beeper makes warning sounds, and the weight column displays flashing “ ”

Upper limit of preset quantity (Non-standard keypad)

1. Whether there is an object on platter or not, press

Q’TY PRESET

key. Press

SAMPLE

key, select “Quantity Preset” mode (Press

UNIT WEIGHT

key to select “Weight Preset” mode)

o

_ stable _

Previous preset value

2. Enter the upper limit intended (Press

CE

key to modify the value entered)

o

_ stable _

Upper limit entered

03004035 18 ZSME200000054

EXCELL PRECISION CO., LTD.

3. Press

SAMPLE

key (Press

CE

key to modify the value entered)

o

_ stable _

4. press

Q’TY PRESET

key, the scale return to the counting mode

o

_

.

Clear off the pre-set upper limit

stable _

To clear the pre-set upper limit of quantity or weight, please follow the above-mentioned operation steps. When entering the pre-set value, please enter “0” instead.

When switching to “weight preset” mode or “quantity preset” mode, previous preset value will be deleted automatically.

If it is standard keypad, use number keys to enter number and then press

Q’TY PRESET

key to finish the setting; If to clear off the pre-set upper limit, press

PRESET CE

key.

2-9 Weight Preset

It’s available to pre-set the upper limit of weight. If the weights are over the limit, the beeper makes warning sounds, and the weight column displays flashing “ ”

Upper limit of preset weight

1. Whether there is an object on platter or not, press

Q’TY PRESET

key. Press

UNIT WEIGHT

key to select “Weight Preset” mode (Press

SAMPLE

key to select “Quantity Preset” mode)

o

_

.

stable _

.

Previous preset value

2. Enter the upper limit intended (Press

CE

key to modify the value entered)

o

_

.

stable _

.

Upper limit entered Previous preset value

3. Press

UNIT WEIGHT

key (Press

CE

key to modify the value entered)

o

_

.

stable _

.

4. press

Q’TY PRESET

key, the scale return to the counting mode

o

_

.

Clear off the pre-set upper limit

stable _

To clear the pre-set upper limit of quantity or weight, please follow the above-mentioned operation steps. When entering the pre-set value, please enter “0” instead.

When switching to “weight preset” mode or “quantity preset” mode, previous preset value will be deleted automatically.

03004035 19 ZSME200000054

EXCELL PRECISION CO., LTD.

2-10 ID Input

Press

ZERO

key, and the screen displays “- - - - - -”. Press

0

key before it disappears.

Enter ID with number keys

Press

MC

key to confirm

o

_

.

ID could be set up to 12 digits. They can be numbers (0~9),

English letters (A~Z), or 9

Press x

key to quit setting stable _

2-11 Item Input

Press

ZERO

key, and the screen displays “- - - - - -”. Press

2

key before it disappears.

Enter Item with number keys

Press

MC

key to confirm

o

_

.

Item could be set up to 12 digits. They can be numbers

(0~9), English letters (A~Z), or

9

Press x

key to quit setting stable _

ID & ITEM are applied in FIX FORMAT or FREE FORMAT.

ID & ITEM could be set up to 12 digits. They can be numbers (0~9), English letters (A~Z), or 9 .

Entering numbers/English letters: Press number key and the digit flashes. Press the same key, and the display shows the number/English letter in cycle. When the entered number/English letter flashes for 2 seconds, the setting will be confirmed and moved to the right place by 1 digit. For example: Press

1

key continuously, and the screen displays 1,P,Q,R,S flashing in cycle.(If to enter too many numbers, please enter 9 to clear superfluous numbers.)

If ID & ITEM are not saved in unit weight preset, the data will be cleared after power off.

1

1 x

1

1

MC

Exit

CE

Move cursor leftward

1

TARE

Move cursor rightward

Enter

03004035 20 ZSME200000054

EXCELL PRECISION CO., LTD.

2-12 Unit Weight Preset

The preset data could be saved in up to 50 addresses

Each address contains: unit weight pre-tare ID and ITEM

2-13-1 Pre-set Unit Weight Operation (Read-in)

Use number keys to enter the unit weight. (The value is 0 or blank without setting)

Press

U.W. PST

key

Press

U.W. PST

key again

Press number keys to select 1 of 50 addresses for saving the data. If it is over 50,

Please re-enter.

Press

U.W. PST

key

2-13-2 Pre-set Unit Weight Saving Operation (Read-out)

Press

U.W. PST

key again

Use number keys to enter preset group that you want. If it is over 50, Please re-enter.

Press

U.W. PST

key again to read-out the data you saved. If the data is blank, it shows NULL.

While read-in or read-out, if the waiting time is over 10 seconds, the scale returns to weighing mode automatically. Press

CE

key to cancel the read-in and read-out.

03004035 21 ZSME200000054

EXCELL PRECISION CO., LTD.

Chapter 3 External Calibration Setting

After starting the machine and it returns to zero, press

ZERO

key and the screen displays

”- - - - - -“. Then press x

key to enter external calibration function setting mode. The weight column displays

Press

TARE

key

Press

TARE

key

Press

TARE

Press

TARE

key key

.

External Function Setting

External Weight Calibration and G Value Calibration

RS-232 and Serial Printer Setting

Exit the Setting

1 x

1

Exit

1

CE

Move cursor leftward

1

TARE

Move cursor rightward

1

MC

Enter

3-1 External Function Setting

Press

MC

key

Enter parameter 00~13

After entering parameter

00, press

MC

key to return to previous level

Return to previous level

Backlight mode setting

Auto. power off setting

Stable range setting for quantity sampling

Auto. unit weight average

A/D sampling speed

“Zero” display range

“Zero” track range

Accumulation ending mode

Pre-tare mode

”Beeper” output setting for quantity limit

Accumulation acceptable condition setting 1

Accumulation acceptable condition setting 2

Combination key Setting

03004035 22 ZSME200000054

EXCELL PRECISION CO., LTD.

3-1-1 Backlight Mode Setting

Press

MC

key

Enter parameter 00~02

Previous setting

Press

MC

key to save the setting

Default Setting: (No backlight)

Backlight is always on.

While weighing (weight is higher than 10d) or pressing any key, backlight be turned on automatically. The backlight is turned off automatically when the scale is idle for 10 minutes. (d=division)

No backlight.

When turning on, the backlight mode is the same as previous setting.

3-1-2 Auto. Power-off Setting

Press

MC

key

Enter parameter 00~10

Previous setting

Press

MC

key to save the setting

Default Setting:

Auto. Power-off function is off.

~

The scale to be automatically power off after the scale in not in use for 1~10 minutes. (If intended to operate continuously, please restart the scale again.)

It can be set up to 10 minutes at most.

1

1 x

1

1

CE

TARE

Move cursor rightward

1

MC

Exit

Move cursor leftward

Enter

03004035 23 ZSME200000054

EXCELL PRECISION CO., LTD.

3-1-3 Stable Range Setting for Quantity Sampling

Press

MC

key

Enter parameter 00~15

Previous setting

Press

MC

key to save the setting

Default Setting:

While quantity sampling, the scale will indicate a stable reading and error is within

±

8d internal value. (d=division)

The higher value makes the sampling faster, but less accurate.

The smaller value makes the sampling slower, but more accurate.

It can’t be shifted after sampling, only when the unit weight is cleared in Brazil version.

3-1-4 Auto. Average Unit Weight Setting

Press

MC

key

Enter parameter 00~01

Previous setting

Press

MC

key to save the setting

Default Setting:

Auto. average unit weight function is off. (Press

SAMPLE

key for manual unit weight calibration)

Auto. average unit weight function is on.

Condition: Auto. unit weight calibration performs when the measured sampling number increase greater than 10% but less than 100% of previous sampling number.

1 x

1

Exit

1

CE

Move cursor leftward

1

TARE

Move cursor rightward

1

MC

Enter

03004035 24 ZSME200000054

EXCELL PRECISION CO., LTD.

3-1-5 A/D Sampling Speed Setting

Press

MC

key

Enter parameter 00~01

Previous setting

Press

MC

key to save the setting

Default Setting:

Low speed is about 7.5 Hz. (Weighing reflection is slow but relatively stable)

Fast speed is about 15 Hz. (Weighing reflection is fast but relatively unstable)

3-1-6 Zero Display Range Setting

Press

MC

key

Enter parameter 00~03

Previous setting

Press

MC

key to save the setting

Default setting: .

Display all

Zero range

±

1 bit will not display division, and displays zero instead.

Zero range

±

2 bit will not display division, and displays zero instead.

If

Zero range

±

3 bit will not display division, and displays zero instead.

is set, when setting pre-tare value, it can not be less or equal to

±

3 bits external value, and so on. When the weight is over 1/3 full capacity and return to 0, this function is activated.

1 x

1

Exit

1

CE

Move cursor leftward

1

TARE

1

MC

Move cursor rightward

Enter

03004035 25 ZSME200000054

EXCELL PRECISION CO., LTD.

3-1-7 Zero Tracking Range Setting

Press

MC

key

Enter parameter 00~03

Previous setting

Press

MC

key to save the setting

Default setting: .

After weight keeps stable for over 1 second, it could track

±

1/4 d.

After weight keeps stable for over 1 second, it could track

±

1/2 d.

After weight keeps stable for over 1 second, it could track

±

1 d.

After weight keeps stable for over 1 second, it could track

±

2 d. (d=division)

Only when gross = 0, zero tracking function is activated.

3-1-8 Accumulation Ending Mode Setting

Press

MC

key

Enter parameter 00~02

Previous setting

Press

MC

key to save the setting

Default Setting:

Press

M+

key. After screen displays accumulation value for 3 seconds, scale returns to weighing mode.

Press

M+

key. And screen displays accumulation value, scale does not return to weighing mode until pressing

CE

key

.

Press

M+

key. And screen does not display accumulation value, but beeper beeps once.

1 x

1

1

CE

Exit

Move cursor leftward

1

TARE

Move cursor rightward

1

MC

Enter

03004035 26 ZSME200000054

EXCELL PRECISION CO., LTD.

3-1-9 Pre-tare mode setting

Press

MC

key

Enter parameter 00~01

Previous setting

Press

MC

key to save the setting

Default setting: .

Traditionally, pre-tare can not proceed when weight on platter. When no weight on platter, press

TARE

key to enter pre-tare value and then press

TARE

key again.

Pre-tare can proceed when weight on platter. (Enter value in

UNIT WEIGHT

and press

TARE

key.)

Pre-tare value can not be more than max. weighing value, or first and second segment point of division; besides, the value can not be less than or equal to the external value set up in

FnC 06.

3-1-10 “Beeper” Output Setting for Quantity Limit

Press

MC

key

Enter parameter 00~01

Previous setting

Press

MC

key to save the setting

Default Setting:

If the quantity exceeds quantity setting (or weight exceeds weight setting), the beeper beeps in unstable situation.

If the quantity exceeds quantity setting (or weight exceeds weight setting), it’s no need to be stable

1 x

1

Exit and the beeper beeps automatically.

1

CE

Move cursor leftward

1

TARE

Move cursor rightward

1

MC

Enter

03004035 27 ZSME200000054

EXCELL PRECISION CO., LTD.

3-1-11 Accumulation Acceptable Condition Setting 1

Press

MC

key

Enter parameter 00~01

Previous setting

Press

MC

key to save the setting

Default setting: .

The scale accepts accumulation only when being stable.

The scale accepts accumulation no matter its being stable or not.

3-1-12 Accumulation Acceptable Condition Setting 2

Press

MC

key

Enter parameter 00~04

Previous setting

Press

MC

key to save the setting

Default Setting:

Only when the weight returns to zero, the scale accepts the next accumulation value. If the weight is near zero band, please adjust the setting in .

The weight is no need to return to zero, the scale accepts the next accumulation value..

That means when no weight on platter, the weight can be accumulated continuously.

The weight must return to zero (gross = 0), and the scale can accept the next accumulation value.

Press

M+

key not to accumulate the value, at the same time, RS-232 transmits the data.

The weight should be less than 1/4 d of zero point, and the scale can accept the next accumulation value.

03004035 28 ZSME200000054

EXCELL PRECISION CO., LTD.

3-1-13 Combination Key Setting

Combination key represents

kg/lb

key or

UNIT WEIGHT PRESET

key. This key contains 2 functions: Unit switching 50 sets for unit weight preset

Press

MC

key

Enter parameter 00~01

Previous setting

Press

MC

key to save the setting

Default setting: .

Press the combination key once to select unit (priority function).

Press the combination key for 3 seconds to preset unit weight (minority function).

Press the combination key once to preset unit weight (priority function).

Press the combination key for 3 seconds to select unit (minority function).

1

1

1 x

1

CE

Move cursor leftward

1

TARE

Exit

Move cursor rightward

MC

Enter

03004035 29 ZSME200000054

EXCELL PRECISION CO., LTD.

3-2 External Weight and G Value Calibration

Press

MC

key

Enter parameter 00~03

After entering parameter

00, press

MC

key to return to previous level

Return to previous level

External weight calibration

Calibrate G value used in local or in verification

1

1

1 x

1

Exit

CE

Move cursor leftward

1

TARE

Move cursor rightward

MC

Enter

03004035 30 ZSME200000054

EXCELL PRECISION CO., LTD.

3-2-1 External Weight Calibration

Zero value can be calibrated separately from the weight calibration value.

X X X

Press

MC

key

If no temperature IC, “notMP” displays in

UNIT WEIGIH

kg

.

No weight display

Make sure that no weight on platter and press

MC

key to read “Zero” kg

.

Calibration poises value

Use

0

~

9

key to modify calibration poises value, place enough poises accord- ing to value entered, and press

MC

key to read calibrated internal value and save into EEPROM.

X X X

A/D value of temperature

Internal value

Press

kg/lb

to switch calibration unit

Press x key to quit “zero” calibration

X X X

X X X X X X

X X X X X X

Internal value

Calibration poises value entered can not be higher than maximum weighing capacity.

Poises weight entered will be compared with internal calibration poises weight. If the actual weight is more than the entered poised weight in 0.9~1.1 times, “Error” displays for 1 second in

WEIGHT

.

Re-enter the calibration poises value, or place the correct weight to operate once again.

If not to calibrate weight, press x key to exit without saving A/D value into EEPROM.

.

kg

Poises weight value on platter

In weight calibration mode,

Put on or remove weight to test. After testing, press

MC key to complete external weight calibration.

X X X X X X X X X

Internal value

1

1 x

1

1

CE

Exit

Move cursor leftward

TARE

Move cursor rightward

1

MC

Enter

03004035 31 ZSME200000054

EXCELL PRECISION CO., LTD.

3-2-2 Calibrate G Value Used in Local or in Verification

y

It is capable for users to set or modify G value for 9 times. If it is the 10 th

revised G value, please enter “06 CGr” to calibrate local G value, and the calibration time will be re-set as “1”. y

Local G value calibration must be done after external weight calibration. y

If the external weight calibration is done after G value calibration, the previous G value will be set as the value used in verification. y

G value modify calculation

G value is the reaction of centrifugal force for free falling object.

Standard G value for equator on earth surface:

G

E

978.03184558 cm/sec

2

= 9.7803184558 m/sec²

Standard G value for polar region:

G p

983.21772792 cm/sec

2

= 9.8321772792 m/sec²

The G value below ground is the object's free fall acceleration at that location.

G value does not decrease gradually from mantle to the earth's core. Gravity in the mantle will reaches its highest value (about 1021 cm/ sec²), and decreases to 0 at the earthe's core.

Standard gravitation acceleration in different latitude ( ψ ) can be calculated by formula described as bellowed descriptions:

G

978.03185

1+0.005278895sin

2

ψ +0.000023462sin

4

ψ

G: cm/sec

2

ψ : Latitude

G value must between 9.78032 m/sec² to 9.83218 m/sec

2

.

03004035 32 ZSME200000054

EXCELL PRECISION CO., LTD.

Press

MC

key to display

Historical revised data

.

Display current revised times and the revised local G value

Press

CE

key Press

TARE

key

Press

MC

key to enter revising mode

Press x key to quit and back to previous level

.

Display previous revised times and the revised local G value

Press

CE

key Press

TARE

key

Press

Press

MC

x key to enter revising mode key to quit and back to previous level

.

Times “01”

To fix the local G value when internal weight calibration is stored

Press

CE

key Press

TARE

key

Press

Press

MC

x key to enter revising mode key to quit and back to previous level

.

Press

MC

key to enter

G value revising mode

Times “00”

To fix the local G value when internal weight calibration is stored

Press x key to quit and back to previous level

.

Enter revised G value

Press

MC

key to finish

Automatically add 1 to times

Press x key to quit and back to previous level

1

1 x

1

1

CE

TARE

Move cursor rightward

1

MC

Exit

Move cursor leftward

Enter

03004035 33 ZSME200000054

EXCELL PRECISION CO., LTD.

3-3 RS-232 and Serial Printer Setting

Press

MC

key

Enter parameter 00~08

After entering parameter

00, press

MC

key to return to previous level

Return to previous level

Baud rate setting

Communication protocol setting

Output data format setting

Output count setting per second in continuous transmission

Operation mode setting

Continuous transmission output condition setting

Zero band setting for auto. transmission

Weight band setting for auto. transmission setting

3-3-1 Baud Rate Setting

Press

MC

key

Enter parameter 00~05

Previous setting

Press

MC

key to save the setting

Default Setting:

(

9,600 bit/sec

)

600 bit/sec

1,200 bit/sec

2,400 bit/sec

4,800 bit/sec

9,600 bit/sec

19,200 bit/sec

If there is free form device, it is 9600 bits/sec transmit.

1 x

1

Exit

1

CE

1

MC

1

TARE

Move cursor rightward

Move cursor leftward

Enter

03004035 34 ZSME200000054

EXCELL PRECISION CO., LTD.

3-3-2 Communication Protocol Setting

Press

MC

key

Enter parameter 00~02

Previous setting

Press

MC

key to save the setting

Default Setting:

(

N, 8, 1

)

N, 8, 1

E, 7, 1

O, 7, 1

If there is free form device, it is 9600 bits/sec transmit.

3-3-3 Output Data Format Setting

Press

MC

key

Enter parameter 00~09

Previous setting

Press

MC

key to save the setting

Default Setting:

(

Fixed format 1

)

Fixed format 1 (details see following page)

Fixed format 2 (details see following page)

Reserved

Same as screen display (general format)

Same as screen display (general format)

Gross weight (general format)

Net weight (general format)

Tare (general format)

Fixed format 3 (details see following page)

Fixed format 4 (details see following page)

Please see “Appendix 1” for output format.

If there is free form device, the setting will be fixed as

1 x

1

Exit

1

CE

Move cursor leftward

1

TARE

Move cursor rightward

1

MC

Enter

Reserved.

03004035 35 ZSME200000054

EXCELL PRECISION CO., LTD.

Fixed format is described as following:

Fixed format 1 “Press

M+

key to print” Fixed format 2 “Press

M+

key to print”

NO. 3

G

N

2.480 kg

2.000 kg

T 0.080 kg

PT 0.400 kg

U/W 1.6003 g

ID: xxxxxxx xxxxx

ITEM: xxxxxxx xxxxx

NO. 3

G 2.480

kg

N 2.000

kg

T

U/W

0.080

kg

0.400

1.60

03 g kg

Q 1250 pc s

If the format in rS1 03 is set that press

M+

or

MC

key to print and the transmission format in rS1 05 is set as continuous or automatic transmission, some content printed out is meaningless.

Fixed format 3 “Press

M+

key to print” Fixed format 4 “continuous or auto. transmission”

NO. 1

N/W 0.500

U/W 1.00013

PCS 500

N/W 0.500

U/W 1.00013

PCS 500

Fixed format 1,2 “Press

MC

key to print”

(Print out total accumulation data and clear data in memory)

================

T/N 3

Fixed format 3 “Press

MC

key to print”

(Print out total accumulation data and clear data in memory)

= = = = = = = = = = =

T/N 3

NO.

Number of Counts Q

Quantity T

Tare PT

Pre-Tare

G

Gross Weight N

Net weight U/W

Unit weight

T/N

Total Number of Counts T/W

Total weight T/Q

Total quantity

ID: 12 digits (max.) ITEM: 12 digits (max.)

03004035 36 ZSME200000054

EXCELL PRECISION CO., LTD.

3-3-4 Output Count Setting Per-second

Press

MC

key

Enter parameter 00~04 Previous setting

Press

MC

key to save the setting

Default Setting:

(

1 count/sec

)

1 count/sec

2 counts/sec

4 counts/sec

8 counts/sec

More than 8 counts/sec

If parameter in due to too long distance.

is set as or , it may not be able to reach transmit counts

If parameter in

If parameter in

is set as , it is not capable of continuous transmission mode. is set as ~ , it is capable of continuous transmission mode.

3-3-5 Operation Mode Setting

Press

MC

key

Enter parameter 00~05 Previous setting

Press

MC

key to save the setting

Default Setting:

Command mode

Continuous transmission + command mode

Auto. transmission + command mode

Manual transmission + command mode

No RS-232 transmission

ZEBERA PRINTER output format

1

1 x

1

1

CE

1

TARE

MC

Enter

If parameter in is set as , the setting in

If there is free form device, the setting will be fixed as .

Please see “Appendix 1” for command mode format.

Exit

Move cursor leftward

Move cursor rightward is fixed as Manual transmission

03004035 37 ZSME200000054

EXCELL PRECISION CO., LTD.

ZEBERA PRINTER output format

1. Press

M+

key to print

? <LF>

PCS <LF>

P 1 , 1 <LF>

G = Gross T = Tare PT = Pretare N = Net

UW = Unit Weight PCS = Quantity , Fill in blanks for zero “0” on the left. n = Net t = Tare + Pretare pcs = Quantity, zero “0” on the left reserved

<LF> = 0x0A line feed

For example: kg

Tare = 0,150 kg

Pre-tare = 0,050 kg

Net = 0,300 kg

UW = 0,5g

PCS = 600

? <LF>

P 1 , 1 <LF>

<LF> = 0x0A (line feed) SP = 0x20 (Blank)

2. Press

MC

key to print

? <LF>

P 1 , 1 <LF>

TN: Total number TW: Total weights TA: Total quantities tn: Total number tw: Total weights ta: Total quantities

NOTE: Fill in zero “0” for the blanks on the left.

03004035 38 ZSME200000054

EXCELL PRECISION CO., LTD.

For example:

TN = 3

TW = 2,395 kg

TA = 23937

? <LF>

P 1 , 1 <LF>

<LF> = 0x0A (line feed) SP = 0x20 (Blank)

3-3-6 Continuous Transmission Output Condition Setting

Press

MC

key

Enter parameter 00~01

Previous setting

Press

MC

key to save the setting

Default Setting:

(

Output all

)

Output all

No output under OL or unstable condition

The setting in will be effective only when the setting is set as

1

1 x

1

1

CE in

TARE

Move cursor rightward

1

MC

Exit

Move cursor leftward

Enter

03004035 39 ZSME200000054

EXCELL PRECISION CO., LTD.

3-3-7 Zero Band Setting for Auto. Transmission

Press

MC

key

Enter parameter 00~99

Previous setting

Press

MC

key to save the setting

Default Setting:

(

External value “5d”

)

External value “0d”

External value “1d”

External value “99d”

The range setting in is related to accumulation acceptable condition in

3-3-8 Weight Band Setting for Auto. Transmission

Press

MC

key

Enter parameter 00~09

Previous setting

Press

MC

key to save the setting

Default Setting:

(

External value “5d”

)

External value “0d”

External value “1d”

External value “99d”

The setting in should be set as

.

1

1 x

1

1

CE

Exit

Move cursor leftward

TARE

Move cursor rightward

1

MC

Enter

03004035 40 ZSME200000054

EXCELL PRECISION CO., LTD.

Appendix 1 RS-232 Full Duplex Format

Table 1 Command Format

Command Format A

Host Command

Slave

MZ Return to zero

Command

CP Clear off pre-tare value

MT Tare CT Clear off tare value

AT Current net weight accumulation & count plus 1 DT Clear off accumulated data and counts

SC Set continuous transmission mode

SM Set manual transmission mode

SA Set automatic transmission mode.

SO Set command mode

UA Shift to first unit UB Shift to second unit

% Cease continuous transmission mode and enter into command mode

Command Format B

Host Command

Slave

RW Read current displaying weight

RG Read gross weight

RN Read net weight

RH Read gross weight (simple)

RU Read unit weight (simple)

Data

RB Read current displaying weight(simple)

RT

RI

Read tare

Read net weight (simple)

RE Read pre-tare (simple)

RD Read accumulated quantity (simple)

RC Read accumulated counts (simple) Rl Read tare (simple)

Rf Read pre-set name (ITEM) Rk Read accumulated weight (simple accumulation format)

Rg Read ID#

RQ Read quantity (simple)

Rh Read weighing unit

Ri Read unit weight unit

Add % before italic and magnified letter to read continuously.

Add # before italic and magnified letter to read stable value only.

Two formats (AB) mentioned above are all RS-232 full duplex. If the slave terminal receives the below-listed messages, it represents Error condition.

E1: Wrong command E2: Wrong format (wrong parameter) E3: Mismatch proceeding condition

If read PLU command, PUL of N group is NULL or unit weight is re-entered, otherwise read PUL command and return value is 255.

Command Format C

According to the command format to modify ID,ITEM ,PT, UW :

ID:

S I A A A A A A A A A A A A CR LF

ITEM:

S C A A A A A A A A A A A A CR LF

PT:

S T 0 0 1

.

0 0 0 CR LF

UW:

S T 0 0 1

.

0 0 0 CR LF

03004035 41 ZSME200000054

EXCELL PRECISION CO., LTD.

Description:

1. 2 previous code is command code (must be capital letter),A is 0-9 or A-Z. Other symbol is unacceptable (because it can’t be showed on LCD).

2.

Decimal point of PT or UW can be moved.

Table 2 Output Format

General Format

Gross weight S T , G S , + 1 .

2 3 .

4 5 6 l b o z

Net 2 .

3 4 .

5 6 T l . g

Tare S T , T R , + 0 1 2 .

3 4 5 6 SP SP k g

+ overload O L , G S , + SP SP SP SP SP SP SP SP SP SP SP SP

CR LF

- overload O L , G S , - SP SP SP SP SP SP SP SP SP SP SP SP

Unstable U S , G S , + 0 1 2 3 .

4 5 6 SP SP l b

Totally 21 bytes (including CR LF)

Simple Format (Price Computing, Counting)

ID# 0 0 0 0 0 0 0 0 0 0 0 2

CR LF

Read preset name SP SP SP SP SP SP SP A P P L E

Totally 14 bytes (including CR LF)

Simple Format

Read current weighing unit 0

Read current price computing unit 1

CR LF

Read current unit weight unit 2

Totally 3 bytes (Including CR LF)

Simple Format (Price Computing, Counting, Weighing)

Tare + 0 1 2 . 3 4 5 6

Pre-tare + 0 1 2 . 3 4 5 6

SP SP SP SP SP

SP SP SP SP SP

CR LF

Unstable + 0 1 2 3 . 4 5 6

Quantity SP 1 2 3 4 5 6 7 8

Accumulated counts

SP 0 0 0 0 0 0 0 1

PLU# SP 0 0 0 0 0 0 1 2

Totally 11 bytes (including CR LF)

Simple Accumulation Format

Accumulated weight SP 0 1 2 3 4 . 5 6 . 7

Accumulated quantity SP 0 1 2 3 4 5 6 7 8 9

Accumulated weight + overflow + SP SP, SP SP SP SP SP SP SP SP

CR LF

Accumulated weight - overflow + SP SP, SP SP SP SP SP SP SP SP

Totally 13 bytes (including CR LF)

03004035 42 ZSME200000054

EXCELL PRECISION CO., LTD.

Appendix 2 Fixed Format RS-232 Transmission Line Description

SCALE

RS-232 PRINTER SCALE

PC

DB 9

DB 9 DB 9

DB 9

2TX

3RX

3TX

2RX

2TX

3RX

5GND

5GND

5GND

Serial Data Transfer / Receive Format

n , 8 , 1

LSB MSB

S 8-bit data STOP

1

0 e , 7 , 1 S 7-bit data P STOP

1

0 o , 7 , 1 S 7-bit data P STOP

1

0

S : Start bit STOP: Stop bit P : Parity bit

03004035 43 ZSME200000054

EXCELL PRECISION CO., LTD.

Appendix 3 ASCII Code Table

Symbol ASCII Symbol ASCII Code

A 41H a 61H 0 30H

B 42H b 62H 1 31H

C 43H c 63H 2 32H

D 44H d 64H 3 33H

E 45H e 65H 4 34H

F 46H f 66H 5 35H

G 47H g 67H 6 36H

H 48H h 68H 7 37H

I 49H i 69H 8 38H

J 4AH j 6AH 9 39H

K 4BH k 6BH

0DH

L 4CH l 6CH

M 4DH m 6DH

N 4EH n 6EH

O 4FH o 6FH

P 50H p 70H

Q 51H q 71H

R 52H r 72H

S 53H s 73H

T 54H t 74H

U 55H u 75H

V 56H v 76H

W 57H w 77H

X 58H x 78H

Y 59H y 79H

Z 5AH z 7AH

03004035 44 ZSME200000054

EXCELL PRECISION CO., LTD.

Appendix 4 7-Segment Display Characters

9

7

8

5

6

3

4

0

1

2

A

B

C

D

E

F

G

H

I

J

K

L

M

W

X

U

V

Y

Z

S

T

Q

R

N

O

P

03004035 45 ZSME200000054

advertisement

Key Features

  • Counts parts, weighs items, and accumulates totals
  • Large, easy-to-read display
  • Simple keypad for easy operation
  • Durable construction for long-lasting use
  • Accurate performance for reliable results
  • Multiple weighing units for versatility
  • Tare and preset functions for added convenience
  • Optional RS-232 interface for data output
  • Battery or AC power for portability or continuous use
  • Auto power-off function to conserve battery life

Related manuals

Frequently Answers and Questions

How do I turn on the Excell FTCH3?
To turn on the Excell FTCH3, simply press the ON/OFF key.
How do I zero the Excell FTCH3?
To zero the Excell FTCH3, press the ZERO key.
How do I count parts using the Excell FTCH3?
To count parts using the Excell FTCH3, first place a sample of the parts on the scale. Then, press the SAMPLE key. The scale will display the average weight of the parts. Next, remove the parts from the scale and press the COUNT key. The scale will start counting the parts as you add them to the scale.
How do I weigh items using the Excell FTCH3?
To weigh items using the Excell FTCH3, simply place the items on the scale. The scale will display the weight of the items in the selected weighing unit.
How do I accumulate totals using the Excell FTCH3?
To accumulate totals using the Excell FTCH3, press the ACCUM key. The scale will start accumulating the total weight of the items placed on the scale. You can view the accumulated total by pressing the TOTAL key.
Download PDF