Title Page
M
ICRO
-CS
COMMUNICATIONS SERVER FOR M
ICRO
MMAC
INSTALLATION GUIDE
MicroMMAC 22ES
10BASE-T HUB
WITH
LANVIEW®
DISPLAY RESET COM 2 COM 1
PWR
CPU
CLN
ATTN STATUS
SETUP NET 7 6 5 4 3
Micro-CS
PORT
7 6 5 4 3 2 1 M INT
RCV
LNK
12 11 10 9 8 7 6 5 4 3 2 1
E
1
12X 11X 10X 9X 8X 7X
2 1
6X
SETUP ETHERNET MODEM
5X 4X 3X 2X 1X
EPIM-1
NOTICE
Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.
The hardware, firmware, or software described in this manual is subject to change without notice.
IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY
INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES
WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING
OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED
IN IT, EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF, KNOWN, OR
SHOULD HAVE KNOWN, THE POSSIBILITY OF SUCH DAMAGES.
© Copyright April 1997 by:
Cabletron Systems, Inc.
P.O. Box 5005
Rochester, NH 03866-5005
All Rights Reserved
Printed in the United States of America
Order number: 9032220 April 1997
MicroMMAC , CSMIM2 , MODMIM , and Micro-CS are trademarks of
Cabletron Systems, Inc.
Annex , Annex Three , Annex3, and Remote Annex 2000 are trademarks of Xylogics, Inc.
HST is a registered trademark of U.S. Robotics, Inc. Courier HST Dual
Standard Fax , Courier V.32 terbo Fax , Total Control , and Adaptive
Speed Leveling (ASL) are trademarks of US Robotics, Inc.
Ethernet is a trademark of Xerox Corporation.
LAT and ULTRIX are trademarks of Digital Equipment Corporation.
UNIX is a registered trademark of UNIX System Laboratories, Inc.
XENIX is a trademark of Microsoft Corporation.
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
WARNING : Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment complies with FCC Rules Part 68. The FCC Registration Number and
Ringer Equivalence Number (REN) are also located on the MicroMMACchassis rear panel . You must provide this information to the telephone company if requested.
FCC Registration Number
3N9USA-21775-MM-E
Ringer Equivalence Number (REN)
0.4B
Micro-CS Installation Guide -ii
SPECIAL REQUIREMENTS FOR CANADA
The Industry Canada Department’s label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. For their own protection users should ensure that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
CAUTION : Users should not make installation connections themselves, but should contact the appropriate electric inspection authority or electrician.
Load Number
The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop can consist of any combination of devices subject only to the requirement that the total of the LNs of all the devices does not exceed 100.
Industry Canada Certification Number
2179 6467A
LN = 4
Micro-CS Installation Guide -iii
:
IC NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Industry Canada.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
EXCLUSION OF WARRANTY
AND DISCLAIMER OF LIABILITY
1.
EXCLUSION OF WARRANTY. Except as may be specifically provided by
Cabletron in writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including Its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE
SUPPLIED TO YOU BY CABLETRON IN WRITING, EITHER EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF
MERCHANTABLITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH
RESPECT TO THE PROGRAM, THE ACCOMPANYING WRITTEN
MATERIALS, AND ANY ACCOMPANYING HARDWARE.
2.
NO LIABILITY FOR CONSEQUENTIAL DAMAGES.
IN NO EVENT SHALL
CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES
WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR
LOSS OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF
BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR
RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR
INABILITY TO USE THIS CABLETRON PRODUCT, EVEN IF CABLETRON
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF
LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR ON
THE DURATION OR LIMITATION OF IMPLIED WARRANTEES IN SOME
INSTANCES THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT
APPLY TO YOU.
-iv Micro-CS Installation Guide
SPECIAL INSTALLATION INSTRUCTIONS
MODEM ONLY
CAUTION : THIS MODEM CARD IS INTENDED TO BE INSTALLED IN CSA
CERTIFIED/UL LISTED EQUIPMENT BY QUALIFIED SERVICE PERSONNEL.
CHECK THE EQUIPMENT OPERATING/INSTALLATION INSTRUCTIONS
AND/OR EQUIPMENT MANUFACTURER TO VERIFY/CONFIRM YOUR
EQUIPMENT IS SUITABLE FOR INSTALLED APPLICATION CARDS.
CAUTION : ALWAYS DISCONNECT MODEM BOARD (THE ONE WITH THE
TELEPHONE PLUG/JACK) FROM THE TELEPHONE SYSTEM WHEN
INSTALLING UPGRADE OPTIONS OR WHEN THE COVERS ARE REMOVED
FROM THE HOST PRODUCT.
CAUTION : APPLY THE ENCLOSED ADHESIVE WARNING LABEL TO THE
OUTSIDE OR THE INSIDE OF THE EQUIPMENT ENCLOSURE ADJACENT TO
THE MODEM CARD.
Micro-CS Installation Guide -v
:
-vi Micro-CS Installation Guide
CONTENTS
CHAPTER 1 INTRODUCTION
1.1
General........................................................................................ 1-1
1.2
Organization of this Document .................................................... 1-1
1.3
Document Conventions ............................................................... 1-2
1.4
Getting Help................................................................................. 1-2
1.5
Micro-CS Overview...................................................................... 1-3
1.5.1
Remote Network Access ................................................ 1-3
1.5.2
Dial-Up Routing .............................................................. 1-3
1.5.3
Terminal and Communications Access .......................... 1-4
1.5.4
System Description ......................................................... 1-4
1.5.5
Micro-CS Front Panel ..................................................... 1-5
1.5.6
System Status LEDs ....................................................... 1-6
1.5.7
Modem Status LEDs ....................................................... 1-7
1.5.8
SETUP Switch ................................................................ 1-7
1.5.9
Port Activity Indicators .................................................... 1-7
1.5.10 Console Port ................................................................... 1-8
1.5.11 Network Port ................................................................... 1-8
1.5.12 Modem Port .................................................................... 1-8
1.6
Micro-CS Physical Characteristics .............................................. 1-9
1.7
Environment ................................................................................ 1-9
1.8
Approvals..................................................................................... 1-9
CHAPTER 2 MICRO-CS INSTALLATION
2.1
General........................................................................................ 2-1
2.2
Console Port Terminal................................................................. 2-1
2.3
Serial Devices.............................................................................. 2-2
2.4
Power-up and Test ...................................................................... 2-3
2.5
Auto-Initializing the ROMs ........................................................... 2-6
2.5.1
Retrieving Boot Information Using BOOTP .................... 2-6
2.5.2
Retrieving Boot Information Using RARP ....................... 2-7
2.6
Software Installation Procedures................................................. 2-8
Micro-CS Installation Guide i
Contents
CHAPTER 3 ROM MONITOR COMMANDS
3.1
General ........................................................................................3-1
3.2
Commands...................................................................................3-3
3.2.1
addr .................................................................................3-3
3.2.2
boot .................................................................................3-6
3.2.3
config.............................................................................3-11
3.2.4
console-baud.................................................................3-11
3.2.5
erase .............................................................................3-13
3.2.6
help................................................................................3-14
3.2.7
image.............................................................................3-14
3.2.8
ipx..................................................................................3-15
3.2.9
lat_key ...........................................................................3-16
3.2.10 mop ...............................................................................3-17
3.2.11 net .................................................................................3-17
3.2.12 option_key .....................................................................3-18
3.2.13 ping................................................................................3-18
3.2.14 ports ..............................................................................3-19
3.2.15 sequence.......................................................................3-21
3.2.16 slip .................................................................................3-22
3.2.17 stats...............................................................................3-24
CHAPTER 4 TROUBLESHOOTING PROCEDURES
4.1
General ........................................................................................4-1
4.2
Power-Up and Boot Procedures ..................................................4-1
4.2.1
Normal Mode...................................................................4-1
4.3
Boot Failures ................................................................................4-5
4.4
Correcting Micro-CS Parameters .................................................4-8
4.5
Load Server Host Not Responding ..............................................4-9
4.6
Micro-CS Dumps........................................................................4-12
APPENDIX A PORT PIN/SIGNAL ALLOCATIONS
A.1
General ....................................................................................... A-1
A.2
Console Port ............................................................................... A-1
A.3
Serial Port ................................................................................... A-2
A.4
LAN Network Port ....................................................................... A-2
A.5
Modem Port ................................................................................ A-3
APPENDIX B CONNECTORS
B.1
General ....................................................................................... B-1
B.2
Additional Cabletron Cables and Connectors ............................. B-2 ii Micro-CS Installation Guide
Contents
APPENDIX C FLASH UPGRADE INSTRUCTIONS
C.1
General........................................................................................C-1
C.2
Contents of the Kit .......................................................................C-1
C.3
Required Tools ............................................................................C-1
C.4
Installation Procedure..................................................................C-2
C.4.1
Installing the Flash Daughter Card..................................C-2
C.4.2
Changing the Boot Method .............................................C-3
APPENDIX D MICRO-CS UPGRADE INSTALLATION
D.1
General........................................................................................D-1
D.2
Locating The Configuration Jumpers...........................................D-1
D.3
Required Tools ............................................................................D-2
D.4
Installation Procedure..................................................................D-3
D.5
Installing the Micro-CS Upgrade..................................................D-4
Micro-CS Installation Guide iii
Contents iv Micro-CS Installation Guide
CHAPTER 1
INTRODUCTION
1.1
GENERAL
Welcome to the Cabletron Systems Micro-CS User’s Guide. Read through this manual to gain an understanding of the features and capabilities of the Micro-CS. A general knowledge of Ethernet and IEEE
802.3 type data communications networks and their physical layer components will be helpful when installing the Micro-CS.
1.2
ORGANIZATION OF THIS DOCUMENT
Chapter 1, Introduction , outlines the contents of this manual, and describes Micro-CS features, installation requirements, network guidelines, getting help, and operating specifications.
Chapter 2, Micro-CS Installation , contains instructions for network connections, attaching to the ports, power up and test information, initializing the ROM, and preparing to load software.
Chapter 3, ROM Monitor Commands , explains accessing the ROM commands and describes them in detail.
Chapter 4, Troubleshooting Procedures , describes how to use the
LANVIEW LED’s to troubleshoot problems.
Appendix A provides port pinout information.
Appendix B lists cabling and connector specifications.
Appendix C provides optional Flash Upgrade instructions.
Appendix D gives Memory Upgrade instructions.
Appendix E explains the installation of the Micro-CS into a
MicroMMAC.
Micro-CS Installation Guide 1-1
Chapter 1: Introduction
1.3
DOCUMENT CONVENTIONS
The following conventions are used throughout this document:
NOTE
Note symbol. Calls the reader’s attention to any item of information that may be of special importance.
!
CAUTION
Caution symbol. Contains information essential to avoid damage to the equipment.
Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or death due to an electrical hazard.
1.4
GETTING HELP f you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact
Cabletron Systems Technical Support:
Phone (603) 332-9400
Monday – Friday; 8 A .
M . – 8 P .
M . Eastern Time
CompuServe
Internet mail
FTP
BBS
GO CTRON from any ! prompt [email protected]
ctron.com (134.141.197.25) anonymous Login
Password your email address
(603) 335-3358
Modem setting 8N1: 8 data bits, 1 stop bit, No parity
For additional information about Cabletron Systems products, visit our
World Wide Web site: http://www.cabletron.com/
1-2 Micro-CS Installation Guide
Micro-CS Overview
•
•
•
•
•
•
•
Before calling Cabletron Systems Technical Support, have the following information ready:
A description of the failure
A description of any action(s) already taken to resolve the problem
(e.g., changing mode switches, rebooting the unit, etc.)
A description of your network environment (layout, cable type, etc.)
Network load and frame size at the time of trouble (if known)
The serial and revision numbers of all Cabletron Systems products in the network
The device history (i.e., have you returned the device before, is this a recurring problem, etc.)
Any previous Return Material Authorization (RMA) numbers
1.5
MICRO-CS OVERVIEW
The Cabletron Micro-CS is a Xylogics Remote Annex 2000 compatible, multi-port communication server designed to reside in the MicroMMAC series of stand-alone hubs. The Micro-CS integrates a communication server with remote dial-in/dial out access, dial-up routing, and terminal and communications access capabilities into the MicroMMAC.
1.5.1
Remote Network Access
The Micro-CS provides network support for: TCP/IP, Novell Netware, and AppleTalk.
1.5.2
Dial-Up Routing
The Micro-CS provides dial-up routing support for UNIX and Novell networks. Using a Micro-CS, Network Administrators can connect two or more networks over a standard telephone line.
Micro-CS Installation Guide 1-3
Chapter 1: Introduction
1.5.3
Terminal and Communications Access
The Micro-CS provides terminal and communications access to users on a local area network. The Micro-CS can connect up to 7 asynchronous serial devices to host computers on a LAN.
1.5.4
System Description
The Micro-CS is a powerful 32-bit device that comes with an Intel 80486
SXLC2 clock-doubled processor. The Micro-CS read-only memory
(ROM) contains firmware for performing power-up self-tests and loading operational code. A non-volatile EEPROM stores the configuration parameters.
The ROM Monitor is an interactive command interpreter that accesses the
ROM’s functions. ROM Monitor commands are issued through a terminal connected to the console port on the Micro-CS . Using the ROM Monitor commands, you can:
•
•
•
Modify and display a set of EEPROM parameters.
Execute interactive diagnostic tests.
Receive information and statistics for the hardware configuration and the network.
• Boot the Micro-CS manually.
The Micro-CS is a diskless device. It obtains operational code either over the network from a host running Micro Annex Communication Software
Version 9.2.6 or above, another Micro-CS configured as a load server, or from self-contained Flash Memory.
The Micro-CS has a watchdog timer that is reset by the software at regular intervals. The watchdog timer reboots the Micro-CS in the unlikely event of an internal software error. This feature allows the
Micro-CS to run for long periods of time without intervention.
A modem upgrade for the Micro-CS is available for added functionality.
It consists of a single daughter card, and can be user installed. The upgrade kit can be purchased separately from Cabletron as part number
CSM-V.34-UGK.
1-4 Micro-CS Installation Guide
Micro-CS Overview
LED indicators provide the user feedback on system activity. Each port connector has an associated LED to indicate activity on the receive data line. Several other LEDs indicate Network Activity, diagnostic failure and other fault connections.
1.5.5
Micro-CS Front Panel
The Micro-CS (Figure 1-1) front panel contains the following:
•
•
•
•
•
•
4 System Indicators
5 Modem status indicators
Modem port indicator (when optional modem is operating)
7 port LEDs
Internal connection indicator
SETUP Switch
MicroMMAC 22ES
10BASE-T HUB WITH LANVIEW®
DISPLAY RESET
COM 2 COM 1
PWR
CPU
CLN
ATTN STATUS
SETUP NET 7 6 5 4
Micro-CS
3
PORT
7 6 5 4 3 2 1 M INT
RCV
LNK
12 11 10 9 8 7 6 5 4 3 2 1
E
1
12X 11X 10X 9X 8X 7X
2 1
6X
SETUP ETHERNET MODEM
5X 4X 3X 2X 1X
EPIM-1
Figure 1-1 Micro-CS front panel
Micro-CS Installation Guide 1-5
Chapter 1: Introduction
1.5.6
System Status LEDs
The front panel LEDs provide information on system status and activity.
SETUP
ATTN
STATUS
NET
INT
PORT
(green)
(amber)
(green)
(green)
(green)
(green)
Table 1-1 : System LEDs
On when Setup button has been pressed within
3 seconds of Setup, indicating Port 1 is now a console port.
Flashing when the unit is in Setup.
NOTE: Both the SETUP and ATTN LED’s will be on when the Micro-CS is in Monitor mode.
On when the Micro-CS requires operator attention.
Flashing when the unit encounters a problem.
On when the unit is loading or dumping.
Flashing when the unit is trying to initiate a load.
Flashes to show network activity on the
Ethernet.
On when the AUI port to the MicroMMAC is selected.
Off when the front panel 10BASE-T port is selected.
Flashes with activity from the numbered port
(eight total, one per port including modem).
1-6 Micro-CS Installation Guide
Micro-CS Overview
1.5.7
Modem Status LEDs
The modem LEDs provide information on modem activity
TxD
RxD
CTS
(green)
(green)
DTR (green)
(green)
DCD (green)
Table 1-2 : Modem LEDs
Flashes to indicate modem has transmitted data to remote modem via dial up link.
Flashes to indicate data received from remote modem over dial up link.
On when optional modem receives Data
Terminal Ready from the Micro-CS.
On until the modem lowers Clear To Send when transmit Data hardware flow control is enabled. Always on during synchronous connections.
On when optional modem receives a valid
Data Carrier Detect signal from a remote modem, indicating that data transmission is possible.
1.5.8
SETUP Switch
The SETUP button allows you to change the operational mode of the
Micro-CS from Normal to Test. It also functions as a Reset button (see
Note below). The Micro-CS automatically powers up in normal mode. To enter test mode, press the SETUP button within three seconds of powering-up.
Additionally, a Setup signal is provided from the MicroMMAC motherboard. When this signal is active, it will perform a cold start of the
Micro-CS.
1.5.9
Port Activity Indicators
The LED activity indicators associated with ports 1-7 blink to indicate data either data transmitted to or received by that port. The “M” port lights to indicate the modem is seeing activity. The 5 modem LED’s blink to indicate the modem is sending or receiving data from the WAN network.
Micro-CS Installation Guide 1-7
Chapter 1: Introduction
1.5.10
Console Port
The Micro-CS uses port 1 as a console port during SETUP. To access the console port, press the Setup switch within 3 seconds of powering-up.
The console port provides access to the ROM Monitor commands when the Micro-CS is in set up mode. After returning to normal mode, Port 1 functions as a serial port. Refer to Appendix B for console pinout information.
1.5.11
Network Port
The Micro-CS can be connected to an Ethernet LAN either one of two ways: through an RJ-45 connector to the MicroMMAC internal AUI, or through an RJ-45 connector on the front panel between the network port and a port on the MicroMMAC. The internal AUI is provided by the
Cabletron EPIM-3PS, provided with the Micro-CS. The Micro-CS automatically sets up the connection, either internally to the
MicroMMAC, or externally to a 10BASE-T port. Refer to Appendix B for port pinout information.
1.5.12
Modem Port
If your Micro-CS is equipped with the optional modem card, the punch out on the faceplate should have been removed to expose the modem port.
This port supports a V.34 modem with an RJ-11 connector allowing modem network access.
If your Micro-CS does not have the optional modem, then connecting to the port is futile. The modem card can be purchased by contacting
Cabletron Customer Support at (603) 332-9400 and ordering part number
CSM-V.34-UGK.
1-8 Micro-CS Installation Guide
Micro-CS Physical Characteristics
1.6
MICRO-CS PHYSICAL CHARACTERISTICS
• Dimensions: Height: 1 inch (2.54 cm)
Width: 12.4 inch (31.5 cm)
Depth: 5.35 inch (13.6 cm)
• Weight: .91 lbs (.14 kg)
• Power: 3A @ 5V
1A @ 12V
1.7
ENVIRONMENT
Operating:
5
°
to 40
°
C (41
°
to 104
°
F)
5% to 90% relative humidity, non-condensing
Storage:
-30
°
to 73
°
C (-22
°
to 164
°
Fº)
1.8
APPROVALS
Safety:
This equipment meets the safety requirements of
UL 1950, CSA C22.2 No. 950, EN60950, IEC 950, and 73/23/EEC.
Electromagnetic Compatability:
This equipment meets the requirements of FCC Part
15, EN 55022, VCCI V-3/93.01, CSA C108.8, EN
50082-1, and 89/336/EEC.
Telecom:
FCC Part 68, Industry Canada CS-02/CS-03
Micro-CS Installation Guide 1-9
Chapter 1: Introduction
1-10 Micro-CS Installation Guide
CHAPTER 2
MICRO-CS INSTALLATION
2.1
GENERAL
The Micro-CS comes factory installed in the MicroMMAC as a
MicroCS-T-22ES, or MicroCS-LT-22ES, or can be ordered seperately as an upgrade kit, part number MICRO-CST-UGK or MICRO-CSLT-UGK.
If you have the upgrade kit, please refer to Appendix E for installation instructions.
Installation procedures for the MicroCS follow those of the Cabletron
Systems MicroMMAC series. For installation and Local Management instructions related to the Ethernet networking functionality of the
MicroCS, please refer to the MicroMMAC documentation.
This chapter explains the connection of serial devices, attaching to the console port, power up and testing, and software installation of your new
Micro-CS. Please read through all the material before powering up to gain an understanding of how to set up the system.
2.2
CONSOLE PORT TERMINAL
In order to access the ROM Monitor and boot the Micro-CS for the first time, the Micro-CS must be connected to a terminal. Connect the console terminal to port 1. Set the terminal to 9600 baud, eight data bits, no parity, one stop bit, and XON/XOFF flow control. The ROM Monitor assumes that this terminal is CRT-based and displays the backspace (BS) character accordingly.
Appendix A describes the console port’s signal/pin allocations.
Micro-CS Installation Guide 2-1
Chapter 2: Micro-CS Installation
Press SETUP within 3 seconds of powering up to put the Micro-CS into
ROM Monitor mode. You can also reset the Micro-CS and enter the ROM
Monitor mode by pressing the SETUP switch for at least three seconds, until the SETUP LED flashes indicating a reset. Release the switch and all the port LEDs will turn on then off. Press the SETUP switch again within 3 seconds after the PORT LEDs have turned off, and the SETUP
LED will be on indicating the Micro-CS is in setup mode. Once the
Micro-CS has successfully completed its start-up diagnostics, the ATTN
LED will turn on indicating ROM Monitor mode. Each subsequent depression of the SETUP switch will toggle the Micro-CS SETUP LED off and on. In order to return to Normal mode, the Micro-CS must be re-booted.
NOTE
The amber ATTN light is ON when the unit is in ROM Monitor state.
2.3
SERIAL DEVICES
The Micro-CS provides 7 total port connections. Port 1 is used for the initial console connection, but reverts to an Annex serial port after bootup.
To connect to serial devices, simply insert one end of the RJ45 cable into one of the seven numbered ports on the front of the Micro-CS. Attach the opposite end of the serial port cable to your serial device.
The Micro-CS serial cables conform to both the RS232 and RS423 specifications regarding the data signals (TxD, RxD). However, it is possible to exceed the specifications’ cable limits given high quality cables that are run in an electrically quiet environment, or a DTE connecting device that uses RS423 drivers. Refer to the DTE manual for information regarding the serial drivers supported. Cabletron only guarantees operation with cables that conform to the appropriate specification. Table 2-4 lists the maximum recommended cable lengths when connecting to an RS232C compliant device.
!
CAUTION
The Micro-CS can incur damage if the cables conduct transients such as those induced by lightning strikes, etc.
2-2 Micro-CS Installation Guide
Power-up and Test
NOTE
Table 2-1 Maximum Recommended Cable Lengths
Line Speed
50 to 19.2kbps
38.4kbps
57.6kbps
115.2kbps
Feet
250
200
100
50
Cable Length
Meters
75
60
30
15
If you exceed these recommended cable lengths, you must compensate for any resulting problems by reducing the baud rate, using low capacitance cable, etc. Exceed these distances at your own risk.
2.4
POWER-UP AND TEST
1.
Power up the MicroMMAC in accordance with the instruction found in the MicroMMAC user documentation.
The Micro-CS now runs its ROM-resident power-up diagnostics. The indicators momentarily light and then turn off, except for the NET indicator.
2.
Verify that the CPU light on the MicroMMAC is blinking/green, and that the LCD reads out correctly (refer to your MicroMMAC documentation for information).
3.
Set the Micro-CS to ROM Monitor mode (SETUP and ATTN LEDs on).
Press SETUP within 3 seconds of powering up to put the Micro-CS into ROM Monitor mode. You can also reset the Micro-CS and enter the ROM Monitor mode by pressing the SETUP switch for at least three seconds, until the SETUP LED flashes indicating a reset.
Release the switch and all the port LEDs will turn on then off. Press the SETUP switch again within 3 seconds after the PORT LEDs have turned off, and the SETUP LED will be on indicating the Micro-CS is in setup mode. Once the Micro-CS has successfully completed its start-up diagnostics, the ATTN LED will turn on indicating ROM
Monitor mode.
Micro-CS Installation Guide 2-3
Chapter 2: Micro-CS Installation
Next, the Micro-CS runs diagnostic tests causing the NET indicator to flash. If the diagnostics complete successfully, the STATUS and
ATTN indicators light, and the ROM Monitor prompt ( monitor::
) appears on the terminal. The tests complete in approximately one minute. If the prompt appears, go to Step 4.
If the STAT and ATTN indicators do not light within one minute or if the indicators flash, a hardware failure has occurred. Contact
Cabletron Technical Support.
4.
Verify the Micro-CS hardware configuration.
At the monitor prompt on the console, type config and press the
Return key. The following is a typical configuration display: monitor:: config
REVISION/CONFIGURATION INFORMATION
ROM Software Rev: 0901
Memory Size: 4 Meg
EEPROM Size: 32736
Installed Alternate Interface: ThinNet
ASYNC Config
Number of Ports: 16
Max Port Speed: 115.2 Kbps
2-4 Micro-CS Installation Guide
Power-up and Test
5.
Record the Ethernet address of the Micro-CS for future reference.
At the monitor prompt, type addr -d and press the Return key. The display looks like this: monitor:: addr -d
Ethernet address (hex): 00-80-2D-00-18-B6
Internet address: <uninitialized>
Subnet mask: 255.255.0.0
Broadcast address: 0.0.0.0
Preferred Load Host address: <any host>
Preferred Dump Host address: 0.0.0.0
Load/Dump Gateway address: <uninitialized>
Type of IP packet encapsulation: <ethernet>
Load Broadcast: Y
NOTE
You are prompted for the gateway address only if the internet address differs from the preferred load host address based on the subnet mask. If these addresses are the same, the
Micro-CS assumes there is no gateway.
6.
Perform the “net” test to verify your network connectivity.
Connect the Micro-CS to the Ethernet network either through the internal AUI, or by connecting a jumper cable from the Ethernet port on the Micro-CS to a MicroMMAC port. At the monitor:: prompt, type “net”.
If the unit passes the test, the console displays “Passed”. If it fails, an error message is displayed.
7.
“Ping” the software load host, as well as the IP address of the
MicroMMAC. This will test the connectivity of the Micro-CS to a remote device.
Micro-CS Installation Guide 2-5
Chapter 2: Micro-CS Installation
At the monitor prompt, type “ping” and then specify the IP address of the remote device. Specify the number of bytes per packet, and the number of packets to be sent. The ping command display looks like this: monitor:: ping 134.141.72.165
PING 134.141.72.165: 64 data bytes
2.5
AUTO-INITIALIZING THE ROMS
The Micro-CS supports the BOOTP and RARP protocols. The ROMs use these protocols to obtain boot information without requiring any manual setup on the Micro-CS.
• BOOTP is a bootstrap protocol that allows a diskless client to determine its Internet address, the Internet address of the server, and the name of the file to be loaded into memory.
• RARP (Reverse Address Resolution Protocol) maps a hardware address into an Internet address.
The ROMs invoke this system of acquiring boot information when a boot is initiated and the Micro-CS’s Internet Address is not initialized. Under this condition the Micro-CS first tries to get boot information via BOOTP; if BOOTP fails, it tries to get boot information via RARP. If neither protocol is successful, the Micro-CS either prompts the user for the
Internet address (if in SETUP mode) or it lights the ATTN LED to indicate the Internet address is not set (if in Normal mode).
2.5.1
Retrieving Boot Information Using BOOTP
For a successful BOOTP retrieval a bootpd must be running on a host on the same network as the Micro-CS and must have the appropriate information in the bootptab file. The Micro-CS’s BOOTP implementation adheres to rfc951, rfc1048, and rfc1084 specifications.
Below is a sample bootptab file entry used to initialize the Micro-CS named terminator.
2-6 Micro-CS Installation Guide
Auto-Initializing the ROMs microcs default:\
:sm=255.255.255.0:gw=132.245.22.66:\
:hn:vm=auto:to=-18000: terminator:\
:ht=1:ha=00802d004879:ip=132.245.22.6
:tc=microcsdefault:
In the previous example:
• sm is the subnet mask;
• gw is the load/ dump gateway address; ht is host type (1=Ethernet);
• ip is the Micro-CS’s Internet Address; ha is the Micro-CS’s hardware address (Ethernet Address); and
• vm is the Vendor Magic Cookie.
When the Micro-CS receives a BOOTP response with the sm, gw, and ip set, it sets the respective parameters: subnet_mask,
load_dump_gateway, and inet_addr. The Vendor Magic Cookie must be set to auto. This indicates that bootpd should respond to the client
(Micro-CS in this case) with whatever format the client requests; the
Micro-CS (client) always requests in the decimal dot notation format
(99.130.83.99). The bootpd adds the address of the host on which it is running as the Server Address in the bootp response message. The ROMs use the Server Address as the preferred load host and store it in the
pref_load_addr parameter.
NOTE
The bootpd must be running on the Micro-CS’s preferred load host.
2.5.2
Retrieving Boot Information Using RARP
If the Micro-CS does not receive a successful BOOTP response it uses
RARP to get the boot information. For a successful RARP retrieval,
TCP/IP must be running on a host that is on the same network as the
Micro-CS and the host’s ARP table must be initialized with the
Micro-CS’s Internet and Ethernet addresses (see the arp man page,
arp -s).
Micro-CS Installation Guide 2-7
Chapter 2: Micro-CS Installation
The only boot information that RARP provides is the Micro-CS’s Internet address. The ROMs save this information in the inet_addr parameter.
The ROMs use default information for the subnet mask and preferred load host. This means the ROMs will broadcast their request.
The host serving the Micro-CS its boot information must be running on the same network as the Micro-CS because the Micro-CS only broadcasts
BOOTP and RARP queries.
2.6
SOFTWARE INSTALLATION PROCEDURES
The Micro-CS’s operational image can be installed from a UNIX host on a network. To do this, the operational code must first be loaded on the
UNIX host. The Micro-CS may also be booted from software loaded on a another Micro-CS or from Flash memory (see Chapter 3). When loading the Micro-CS software for the first time, use the ROM Monitor commands. At the monitor prompt:
1.
Execute the erase command to clear the EEPROM. (See the erase command in Chapter 3.)
2.
Execute the addr command to:
Enter the Micro-CS’s Internet address.
Modify any other parameters that the Micro-CS may require for the initial boot, i.e., the preferred load host’s Internet address and the subnet mask. (See the addr command in Chapter 3.)
3.
If you are booting the Micro-CS using a Serial Line Internet Protocol
(SLIP) network interface, you must:
2-8 Micro-CS Installation Guide
Software Installation Procedures
Use the slip command to modify the port parameters for the SLIP network interface (see the slip command in Chapter 3).
Use the sequence command to list the SLIP network interface in the load/dump interface list (see the sequence command in Chapter 3).
4.
Execute the boot command (see the boot command in Chapter 3).
After successful execution of the boot command, your Micro-CS should display the Annex prompt. If the Micro-CS was booted from the monitor mode, the SETUP button should be depressed once to turn off the SETUP
LED.
Micro-CS Installation Guide 2-9
Chapter 2: Micro-CS Installation
2-10 Micro-CS Installation Guide
CHAPTER 3
ROM MONITOR COMMANDS
3.1
GENERAL
This chapter describes the ROM Monitor commands. These commands are accessed through a terminal connected to port 1 when the Micro-CS is in SETUP mode. Pressing the SETUP switch within 3 seconds of powering up puts the Micro-CS into Set Up mode.
The ROM Monitor commands allow you to set a number of EEPROM parameters. Some of these parameters, like the unit’s Internet address, are required for booting the Micro-CS; some parameters, like the broadcast address, are required if the network configuration differs from the supplied defaults. Table 3-1 lists the ROM Monitor commands.
Other parameters, although not required, are recommended for the
Micro-CS’s initial boot. Setting these parameters rather than using the assigned defaults minimizes errors during the initial boot. For example, setting the parameter that defines the preferred load host enables the
Micro-CS to load by requesting assistance from a specific host rather than by broadcasting that request to all hosts on the Ethernet.
You can define the same parameters using the Network Administrator
(na) program as you can using the ROM Monitor. ROM Monitor commands generally provide data about current EEPROM parameters.
When appropriate, they also display a prompt that allows the operator to change those parameters. Default or current values for parameters are displayed in brackets. For example:
Enter broadcast address [132.245.6.255]:
At the prompt enter a different value or press the Return key <cr> to leave the displayed value unchanged.
You can use unique abbreviations for all ROM Monitor commands except
erase. For example, enter boot as bo, and enter net as n. If you enter an abbreviation that is not unique enough, an error message is displayed on the console terminal.
Micro-CS Installation Guide 3-1
Chapter 3: ROM Monitor Commands addr [-d] boot [-v] [<file>] boot [-l] [<file>] config console-baud erase help (or “?”) image [-d/<file>] ipx [-d] lat_key [-d] mop [-d] net option_key [-d] ping ports [-d] sequence
[-d | <list>] slip [-d] <port> stats [-slip]
Table 3-1 ROM Monitor Command
Displays and sets EEPROM values relevant to network addressing, including the Micro-CS’s Internet address.
Manually boots and loads the Micro-CS’s operating code.
Erases the existing Flash memory and copies a new image to Flash.
Displays the current hardware configuration and revision levels.
Changes the console port’s baud rate.
Erases non-volatile memory.
Display the list of ROM Monitor commands.
Displays and/or sets the load image and TFTP load dump names.
Sets IPX load/dump file server.
Sets LAT key.
Sets MOP load/dump address.
Executes an Ethernet stand-alone external loopback test.
Sets or displays the option key.
Sends ICMP ECHO_REQUEST, host [data size]
[npackets].
Shows the current status of all ports and tests specified port(s).
Displays and edits the load/dump interface list.
Configures an SL/IP interface.
Displays current network statistics gathered by the
ROM.
3-2 Micro-CS Installation Guide
Commands
3.2
COMMANDS
Following is an explanation of each of the ROM monitor commands, syntax and other usage information.
3.2.1
addr
The addr command displays and sets several Micro-CS operating parameters (EEPROM values) relevant to IP network addressing:
• Internet address.
• Subnet mask.
• Broadcast address.
• Preferred Load Host address.
• Preferred Dump Host address.
• Load/Dump Gateway address.
• Type of IP Packet encapsulation.
• Load Broadcast
The addr -d command also displays the unit’s ROM-resident Ethernet address in hexadecimal notation (see the CSMIM/MicroCS
Administrator’s Guide for UNIX). The command syntax is:
addr [–d]
If you enter the addr command without the –d argument, the console prompts you for each Internet address. Enter Internet addresses using the standard decimal dot (.) notation.
The addr –d command displays the Micro-CS’s Ethernet address, IP address, subnet mask, broadcast address, preferred load host address, preferred dump host address, load/dump gateway address, IP encapsulation type, and Load Broadcast. The addr -d command cannot be used to make changes to any of the displayed parameters.
Micro-CS Installation Guide 3-3
Chapter 3: ROM Monitor Commands
The addr command display looks like this: monitor:: addr
Enter Internet address [<uninitialized>]:: 192.9.200.214
Internet address: 192.9.200.214
Enter Subnet mask [255.255.0.0]::
Enter Broadcast address [0.0.0.0]:: 192.9.200.0
Broadcast address: 192.9.200.0
Enter Preferred Load Host address [<any host>]:: 192.9.200.88
Preferred Load Host address: 192.9.200.88
Enter Preferred Dump Host address [0.0.0.0]:: 192.9.200.88
Preferred Dump Host address: 192.9.200.88
Enter Load/Dump Gateway address [<uninitialized>]:: 192.9.200.
Load/Dump Gateway address: 192.9.200.88
Select type of IP packet encapsulation (ieee802/ethernet)
[<ethernet>]::
Load Broadcast Y/N [Y]::
The addr -d command display looks like this: monitor:: addr -d
Ethernet address (hex): 00-80-2D-00-C6-1E
Internet address: 192.9.200.214
Subnet mask: 255.255.0.0
Broadcast address: 192.9.200.0
Preferred Load Host address: 192.9.200.88
Preferred Dump Host address: 192.9.200.88
Load/Dump Gateway address: 192.9.200.10
Type of IP packet encapsulation: <ethernet>
Load Broadcast: Y
3-4 Micro-CS Installation Guide
NOTE
Commands
The Micro-CS must have an Internet (IP) address in its memory before it can load its operational image across the Ethernet via the IP protocol.
Therefore, you must enter the IP address before booting the Micro-CS from a UNIX load host. If you do not define an IP address for the
Micro-CS, it will attempt to learn the address using BOOTP or RARP. If you do not define a subnet mask, the Micro-CS uses the generic mask for the specified IP address.
The Micro-CS tries to boot from a preferred UNIX load host. If you do not define a preferred load host, the Micro-CS broadcasts its load request on the subnet and loads software from the first host that responds.
If the part of the IP address containing the network address differs from the preferred load or dump host, that host must be reached through a gateway. The addr command prompts you for this gateway’s IP address.
The Micro-CS uses the broadcast address parameter when loading a file.
If this parameter contains a specific address (for example,
132.245.6.255), the Micro-CS uses only that address for broadcast. If the value is all zeroes (0.0.0.0), the ROM Monitor tries various combinations of broadcast addresses and subnet or network broadcasts. The Micro-CS broadcasts its request three times for each possible combination of broadcast addresses.
You can specify the IP encapsulation type as either ethernet for Ethernet, or ieee802 for IEEE 802.2/802.3. The default IP encapsulation is
ethernet. Many systems have hardware Ethernet interfaces that are IEEE
802.3 compliant, but very few actually do 802.3 IP packet encapsulation.
Do not change this parameter unless you know absolutely that your Ethernet does 802.2/802.3 IP packet encapsulation. An incorrect IP encapsulation type prevents your Micro-CS from booting.
Micro-CS Installation Guide 3-5
Chapter 3: ROM Monitor Commands
3.2.2
boot
The boot command requests the loading of appropriate Micro-CS operating software from the preferred load host. The command syntax is:
boot [–lv | filename]
NOTE
The boot –l command is supported only if the self-boot option
(Flash) is installed.
Typing the letter q or CONTROLC interrupts the boot.
If you try to boot with a non-existent image file name, the
Micro-CS will hang as it searches for the image. You must press the RESET button to recover.
A successful boot disables the Console and the ROM monitor.
The boot command accepts a file name for the Micro-CS’s image. If the file name is not specified, boot displays the default file name and prompts for one. If you do not provide a file name, or have not defined one for the
Micro-CS, boot requests the default file oper.56.enet. You can also enter a file name using the image command.
The Micro-CS boots from the defined preferred load host (UNIX/IP,
Novell/IPX, or VAX VMS/MOP). If the preferred load host is not defined or does not respond, the Micro-CS broadcasts on the Ethernet and loads from the first host that responds.
To initiate loading, the Micro-CS sends a load request message to the selected host. After receiving a response, the Micro-CS loads its operational code to RAM memory. When loading is complete, it transfers control to the newly-loaded program. The Micro-CS displays a symbol on the console for each data block received during the boot.
When the Micro-CS begins to boot, it displays the load server host’s IP address. If the unit does not boot successfully after several attempts, it displays a boot attempt failed message; if the unit has opened the boot file and an error occurs during the boot process, it displays a boot error report on the console and returns to the ROM Monitor. The boot error report can help determine the cause of the boot failure.
3-6 Micro-CS Installation Guide
Commands
During a boot, the console may display four possible status symbols: “.” indicates received data blocks, “?” indicates unanswered requests, “*” indicates transmission errors, and “! ~XXXX~” is a status word from the
Ethernet chip on the Micro-CS indicating a gross problem with the
Ethernet connection (if this symbol appears in your boot command display, contact technical support).
The status word “! ~XXXX~”, where XXXX are four hexadecimal digits, decodes as follows:
8000 = Command complete
4000 = Chip is busy
2000 = Command completed without error
1000 = Command aborted by an abort command
800 = Late collision detected
400 = Carrier lost
200 = CTS lost
100 = DMA underrun
80 =
40 =
Transmission deferred because link was busy
Collision detected during interframe spacing
20 =
10 =
(SQE/Heartbeat detected)
Excessive collisions
Reserved
The lowest nibble (bits 3 to 0) are a count of collisions during this transmission. For example:
~8802~ = Complete, Late collision, 2 collisions
~8841~ = Complete, Late Collision, SQE detected, 1 collision
Micro-CS Installation Guide 3-7
Chapter 3: ROM Monitor Commands
The boot command display (using bfs) looks like this: monitor:: boot
Enter boot file name[(ip) “oper.56.enet”,\
(mop) “OPER_56_ENET.SYS”]::
Requesting default boot file “OPER_56_ENET.SYS” for MOP/VMS\ loads and “oper.56.enet” for all other protocols.
Unanswered requests shown as ‘?’,transmission errors as ‘*’.
Requesting boot from 192.9.200.88 via Ethernet...
Booting BFS file using open delay of 8
Booting BFS file from 192.9.200.88
Header received OK. Received data blocks shown as ‘.’.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. .. . . . . . . . . . . ? . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. * . . . . . . . . . . . . . . . . . . . . . . . . . . . . * .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . ? . . . . . . . . . . . . . . . .
. . . . . . . . . . EOF
The next example shows a boot using tftp. The Micro-CS always tries to open a file using bfs first. If unsuccessful, the Micro-CS uses tftp to open the file.
monitor:: boot
Enter boot file name [(ip) “oper.56.enet”, \
(mop) “OPER_56_ENET.SYS”]::
Requesting default boot file “OPER_56_ENET.SYS” for MOP/VMS\
loads and “oper.56.enet” for all other protocols.
Unanswered requests shown as ‘?’,transmission errors as ‘*’.
Requesting boot from 192.9.200.88 via Ethernet...
Booting BFS file using open delay of 8
?
Booting TFTP file using open delay of 8
Booting TFTP file from 192.9.200.88
Header received OK. Received data blocks shown as ’.’.
.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .. . . . . . . . . . . ? . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . * . . . . . . . . . . . . . . . . . . . . . . . . . . .
. * . . . . . . . . . . . . . . . . . . . ? . . . . . . . . . .
. . . . . . . . . . . . . . . . EOF
3-8 Micro-CS Installation Guide
Commands
The boot –l command downloads and saves the operational image to non-volatile memory, erases the existing Flash memory, copies the new image from non-volatile memory to Flash memory, and then executes the image.
NOTE
The boot –l command is supported only if the self-boot option is installed.
After executing a boot –l, the ls command may not show the newly-loaded image.
The boot –l command display looks like this: monitor:: boot –l
Enter boot file name [(ip) “oper.56.enet”, \
(mop) “OPER_56_ENET.SYS”]::
Requesting default boot file “OPER_56_ENET.SYS” for \
MOP/VMS loads and “oper.56.enet” for all other protocols.\
Unanswered requests shown as ‘?’, transmission errors as\ ‘*’.
Requesting boot from 192.9.200.88 via Ethernet...
Booting BFS file using open delay of 8
Booting from 192.9.200.88
Header received OK. Received data blocks shown as ‘.’.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
. . . . . . . . . . . . . . . . . . . .EOF
Saving image into storage device ...
Erasing device
|----------------------------|
..............................
Erase completed
Storing image .............
Storage completed
Beginning execution of image...
Annex Command Line Interpreter * Copyright 1993, 1995\ Xylogics,
Inc.
annex:
Micro-CS Installation Guide 3-9
Chapter 3: ROM Monitor Commands
NOTE
Only use the boot -l command when reloading your Flash memory (e.g., when upgrading to a new version of software).
Make sure that you have a properly configured load host available or you will erase your image from Flash and will not be able to load a new one.
The boot –v command displays the boot in verbose mode. This output includes the turnaround time in milliseconds for each request. This value equals the time lapse between sending the request and receiving the proper reply from the host.
When the boot is complete, verbose output includes a display of network statistics: monitor:: boot –v
Enter boot file name [(ip) “oper.56.enet”, \
(mop) “OPER_56_ENET.SYS”]::
Requesting default boot file “OPER_56_ENET.SYS” for MOP/VMS\
loads and “oper.56.enet” for all other protocols.
Unanswered requests shown as ‘?’, transmission errors as ‘*’.
Requesting boot from 192.9.200.88 via Ethernet...
Booting from 192.9.200.88 (42 msec)
Header received OK. Received data blocks shown as msec
turnaround time.
4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 4 4 4 4
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 5 4 4
4 4 4 4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 4
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 24 4 4 6 4 10 4 6
73 4 4 5 4 4 4 4 4 9 4 4 11 4 4 4 4 4 4 4 4 4 4 4 4 4 3 4 4 4 4 4
4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 11 6 4 4 4 4
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
4 4 4 4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 4
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 EOF
Ethernet Statistics
Frames Received: 1031
CRC Errors: 0
Alignment Errors: 0
Resource Drops: 9
Bus Wait Drops: 0
Bad Types/Lengths: 0
Carrier Sense Losses: 0
Clear to Send Losses: 0
Collisions Detected: 9
Excessive Collision Losses: 0
3-10 Micro-CS Installation Guide
Commands
3.2.3
config
The config command displays the Micro-CS’s total number of ports, total amount of memory, the ID number, the serial number, the major and minor hardware revision numbers, and the ROM software revision number. The config command display contains information describing whether or not Flash ROM is installed. The command syntax is: config
The config command display looks like this: monitor:: config
REVISION/CONFIGURATION INFORMATION
ROM Software Rev: 0901
Board ID: 56 Board Type: Micro-CS
CPU Type: 486SXLC2 Ethernet Address: 00-80-2D-00-C6-1E
Memory Size: 4 Meg
Flash Size: 2 Meg Flash ID: 8989
EEPROM Size: 32736
Installed Alternate Interface: ThinNet
ASYNC Config
Number of Ports: 16
Max Port Speed: 115.2 Kbps
3.2.4
console-baud
The console-baud command changes the console port’s baud rate. Thus, the console port can interface with any modem to which it is connected.
When the baud rate is entered as auto, the Micro-CS detects the baud rate of the incoming line and adjusts its baud rate accordingly. This command provides support for remote troubleshooting. The command syntax is: console-baud
Micro-CS Installation Guide 3-11
Chapter 3: ROM Monitor Commands
The command display looks like this: monitor:: console-baud
Remote Diagnostic Test Mode
In order to use the remote diagnostic functionality, you must first connect a modem to the console port of the
Annex. The modem should be configured such that DTR is forced on, carrier detect and DSR are set normal, and auto-answer is enabled. Once this is done, contact your service representative for remote diagnostic maintenance.
To enter “Autobaud Mode”, please type “Auto”. To
“manually” configure the Annex console port, please type in the desired baud rate. To return to the “monitor::” prompt strike the “carriage return <CR>” key.
[Baudrate Range: 50-9600 BAUD]
Select Baudrate []::
NOTE
This command has no effect on the port’s baud rate after the
Micro-CS is booted
To provide remote access to the Micro-CS ROMs:
1.
From a site local to the Micro-CS:
• Set the Micro-CS into test mode so the monitor prompt appears on the console.
• Set the modem into auto-answer mode.
2.
From the Micro-CS console port:
• At the monitor prompt, enter console-baud.
• At the Select baud rate prompt, enter the appropriate baud rate or auto.
• Connect the modem to the Micro-CS’s console port.
3-12 Micro-CS Installation Guide
Commands
3.
From the remote site:
• Dial into the modem connected to the Micro-CS.
• Type RETURN until the monitor prompt appears.
3.2.5
erase
The erase command erases the contents of non-volatile memory, including the Micro-CS’s IP address. This command also restores the parameters to their factory defaults. The syntax is: erase
If the self-boot option is installed, the erase command prompts for which non-volatile memory to erase: EEPROM or FLASH. Entering 1 at the prompt causes the Micro-CS to erase the EEPROM memory
(configuration information); entering 2 at the prompt causes the
Micro-CS to erase the Flash memory (self-boot image).
The erase command display looks like this: monitor:: erase
1) EEPROM (i.e. configuration information)
2) FLASH (i.e. self boot image)
Enter 1 or 2 :: 1
Erase all non-volatile EEPROM memory? (y/n) [n]:: y
Erasing <16352 or 8160 bytes> of non-volatile memory.
Please wait . . .
.
.
.
16K->|Data 0xff
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16K->|Data 0x0
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Initialized checksum record installed
Micro-CS Installation Guide 3-13
Chapter 3: ROM Monitor Commands
If the self-boot option is not installed, the command display looks like this: monitor:: erase
Erase all non-volatile EEPROM memory? (y/n) [n]:: y
Erasing <16352 or 8160 bytes> of non-volatile memory.
Please wait . . .
16K->|Data 0xff
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16K->|Data 0x0
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Initialized checksum record installed
NOTE
The erase command does not erase the Ethernet address.
Since the erase command erases the IP address, you must use the addr command to re-enter the Micro-CS’s IP address before reloading any software.
3.2.6
help
Entering help, or ?, displays brief descriptions of the Micro-CS ROM
Monitor commands.
3.2.7
image
The image command sets and displays the name of the image file containing the Micro-CS’s software. The command syntax is:
image [–d | filename]
The filename argument permits up to 100 characters. To return the image name to its default, enter a pair of double-quote characters (""). The default image name is oper.56.enet. The image command display looks like this: monitor:: image
Enter Image name: [(ip) "oper.56.enet", (mop)
"OPER_56_ENET.SYS"]::
Enter TFTP Load Directory [""]::
Enter TFTP Dump path/filename ["dump.192.9.200.88"]::
3-14 Micro-CS Installation Guide
Commands
The image –d command display looks like this: monitor:: image -d
Image name: Default (ip): "oper.56.enet"
Default (mop): "OPER_56_ENET.SYS"
TFTP Load Directory: ""
TFTP Dump path/filename: "dump.192.9.200.88"
SELF image name: "oper.56.enet"
NOTE
The SELF image name appears only if the self-boot image is loaded.
If the image file name contains more than 16 characters, it is truncated when MOP is attempted.
3.2.8
ipx
The ipx command sets several parameters associated with IPX booting and dumping. This is useful when loading the Micro-CS’s operational image from a Novell file server. The command syntax is:
ipx [–d]
The ipx command display looks like this: monitor:: ipx
Enter IPX file server name [<uninitialized>]::mars
Enter Frame type, 0=802.3 1=Ethernet II 2=802.2 3=SNAP\
[802.3]::
Enter IPX dump user name [<uninitialized>]::susans
Enter IPX dump password [<uninitialized>]::********
Verify IPX dump password []::********
Enter IPX dump path [<uninitialized>]::SYS:\user\susans\
Micro-CS Installation Guide 3-15
Chapter 3: ROM Monitor Commands
The ipx –d command displays the current settings for all of the entries.
The command display looks like this: monitor:: ipx -d
IPX preferred load file server: "MARS"
IPX Frame type: “802.3”
IPX dump user name: "SUSANS"
IPX dump password: <SET>
IPX dump path name: "SYS:\user\susans\"
3.2.9
lat_key
The lat_key command allows you to set the LAT key from the ROM monitor.
NOTE
The lat_key command is optional and may be purchased separately.
The command syntax is:
lat_key [–d]
The lat_key command display looks like this: monitor:: lat_key
Enter LAT_KEY: [<uninitialized>]::
The lat_key –d command displays the current LAT key setting: monitor:: lat_key -d
LAT_KEY: <uninitialized>
3-16 Micro-CS Installation Guide
Commands
3.2.10
mop
The mop command sets the MOP load/dump address. This is useful when the loading the Micro-CS’s operational image from a VAX VMS load host. The command syntax is:
mop [–d]
The mop command display looks like this: monitor:: mop
Enter preferred MOP load/dump address [<uninitialized>]::
Load Broadcast Y/N [Y]::
The mop –d command displays the current MOP settings: monitor:: mop -d
MOP preferred load/dump address <uninitialized>
Load Broadcast: Y
3.2.11
net
The net command executes an Ethernet transceiver loopback test on the local area network. The command syntax is: net
The net command display looks like this: monitor:: net
Network test – PASSED
This transciever loopback test sends out a short test packet from the
Micro-CS through the MicroMMAC to test the integrity of the network.
One of the Ethernet connections (internal AUI or external connection) must be valid for this test to pass.
Micro-CS Installation Guide 3-17
Chapter 3: ROM Monitor Commands
If the unit passes this test, the console displays PASSED. If the Micro-CS fails, the console displays an error message. Failing this test indicates that the Micro-CS failed to communicate with the MicroMMAC. Contact
Cabletron Systems Technical Support.
3.2.12
option_key
The option_key command loads an option key from the ROM monitor.
The command syntax is:
option_key [–d ]
The option_key command display looks like this: monitor:: option_key
Enter option_key [<uninitialized>]::
The option_key –d command displays the current settings: monitor:: option_key -d option_key: <uninitialized>
3.2.13
ping
The ping command sends an Internet Control Message Protocol (ICMP) mandatory ECHO_REQUEST datagram to elicit an ICMP
ECHO_RESPONSE from a host or gateway. ECHO_REQUEST datagrams (pings) have an IP and ICMP header, followed by a structured time value and an arbitrary number of pad bytes that fill out the packet.
The syntax for this command is:
ping host_ip_address [data_size] [npackets]
The host_ip_address entry is the Internet address of the host or gateway from which you wish to elicit a response.
The optional data_size entry is the number of bytes sent in a datagram packet. The default value is 64 and the maximum value is 1024.
3-18 Micro-CS Installation Guide
Commands
The optional npackets entry is the number of packets to transmit. If you specify npackets, then you must also specify a data_size.
The ping command display looks something like this: monitor:: ping 132.245.33.69
PING 132.245.33.69: 64 data bytes
To exit out of ping either wait for npackets to be transmitted or, at any point, type q . The ping statistics display upon exit.
3.2.14
ports
The ports command tests serial line ports, exercising both the data lines and the control lines for each serial port specified. The syntax for this command is:
ports [–d]
Each serial port to be tested must be looped-back with a loopback plug to test both the data lines and the control lines (the accessory kit provides a loopback plug). Connect this plug to the connector on the Micro-CS that corresponds to the port to be tested.
NOTE
Do not run the ports command for a port to which a device is connected. The test will transmit data to the device and toggle its control lines.
When invoked, the command displays a menu of options.
Micro-CS Installation Guide 3-19
Chapter 3: ROM Monitor Commands monitor:: ports
Individual Port Tests (Data and Control Lines)
Some important notes:
- All Serial Ports (1-7) which are to be tested require a loopback plug in order to pass the Data Line and Control Line loopback tests.
WARNING. If there is a device instead of a loopback plug connected to the port being tested, the device will have data transmitted to it and its Control Line toggled.
Ports with faulty Control Lines:
Ports with faulty Data Lines:
Enter port number or range of ports to test (Return to exit):: 3
Enter the number of times to loop on this test [1]::
Testing data lines on channel 3
ERROR -- Data line loopback failure on port 3 Testing modem signals on channel 3
ERROR -- No RTS/CTS turning (ON) loopback interrupt sensed on
Chan 3 !
Pressing the RETURN key after the prompt Selection (Return to exit) returns you to the monitor prompt.
If you enter the ports –d command, only the data lines are tested. The outgoing control lines are asserted during this test.
monitor:: ports -d
Individual Port Tests (Data Lines)
Some important notes:
- All Asynch Serial Ports (2-16) which are to be tested require a loopback plug in order to pass the Data Line loopback tests.
WARNING. If there is a device instead of a loopback plug connected to the port being tested, the device will have data transmitted to it.
You may enter a list of ports to test separated by spaces/commas.
You may also enter ranges of ports, such as 2-16.
Ports with faulty Data Lines: 3
Enter port number or range of ports to test (Return to exit)::
3-20 Micro-CS Installation Guide
Commands
3.2.15
sequence
The sequence command edits the load/dump interface list. This list determines the order of the network interfaces, and either the local area network (LAN) or the SLIP interface the Micro-CS will use for loading and dumping. The default, net, uses the LAN interface. The list can contain up to four interfaces. If the Micro-CS fails to boot using the first interface, it will try the next, and then the next interface, and then repeat the sequence. The command syntax is:
sequence [–d] | [interface[,interface]. . .]
Specify the LAN interface by selecting net; specify each SLIP interface as slnn, where nn is a port number; and specify self-boot by selecting self.
Separate each interface with a comma or a space. Enter the interface list as an argument to the command; otherwise, the console displays a list of available interfaces and prompts for a new list.
In the following example, interfaces are assigned to the load/dump sequence list. Ports 12, 14, and 15 can be added to the list because they were configured earlier as SLIP interfaces: monitor:: sequence
Enter a list of 1 to 4 interfaces to attempt to use for downloading code or upline dumping. Enter them in the order they should be tried, separated by commas or spaces. Possible interfaces are:
Ethernet: net
SL/IP: sl12,sl14,s115
SELF: self
Enter interface sequence [net]:: sl12, net
Interface sequence: sl12,net
NOTE
The SELF option appears only if the self-boot image is loaded.
Micro-CS Installation Guide 3-21
Chapter 3: ROM Monitor Commands
If you enter the command with the –d argument, the console displays the current load/dump interface list. You cannot specify both the –d argument and the interface list with the same command. The sequence –d command display looks like this: monitor:: sequence -d
Interface sequence: sl12,net
Entering a number for a port that has not been configured properly for
SLIP causes the Port nn is not configured for SL/IP message to display, where nn is the port number.
The Micro-CS can slip boot over any port except Port 1.
NOTE
3.2.16
slip
The slip command defines a serial port as a Serial Line Internet Protocol
(SLIP) interface. This command defines a number of port parameters.
The command syntax is:
slip [–d] [port]
After entering the command, you are prompted for each parameter. The
port is the number of the serial port to be configured with this command.
If you do not enter a port number, you will be prompted for one. Table
3-2 lists the information for which the slip command prompts.
Entering slip –d causes the command to display all the current settings.
3-22 Micro-CS Installation Guide
Commands
Table 3-2 . The slip Command Prompts
Prompt
Allow SLIP on this port
Enter local endpoint address
Enter remote endpoint address
Enter remote load/dump host address
Description
Modifies the port’s mode. A y response changes the port to a SLIP interface. An n response changes the port’s mode to CLI. The port is not available as a SLIP interface and the SLIP parameters are ignored. The default is n.
Specifies the Micro-CS IP address for this SLIP interface. The Micro-CS boots over the SLIP interface only if this address is set.
Specifies the IP address of the remote end of the
SLIP interface.
Specifies the IP address of the remote host to which load and dump requests are sent. This address is required only if the remote host is a gateway and not the load host. By default, this is the same as the remote end-point address.
Should this interface be used for memory dumps
Enables the Micro-CS to use a SLIP interface for memory dumps. The default is y.
Enter the baud rate
Enter the number of stop bits
Enter the parity
Specifies the baud rate of the serial interface. The default is 9600.
Pressing the RETURN key accepts the default
(one). Generally, SLIP implementations require the default.
Pressing the RETURN key accepts the default
(none). Generally, SLIP implementations require the default.
Micro-CS Installation Guide 3-23
Chapter 3: ROM Monitor Commands
The slip command automatically sets the number of data bits to 8 for all
SLIP interfaces. The number of data bits does not include the start, stop, or parity bits. The slip command display looks like this: monitor:: slip
Line number (1-16):: 6
Allow SL/IP on this port? (y/n) [n]:: y
Enter local endpoint address [0.0.0.0]:: 192.9.200.214
Local endpoint address: 192.9.200.214
Enter subnet mask [255.255.255.0]::
Constructed new subnet mask.
Enter remote endpoint address [0.0.0.0.]:: 192.9.200.0
Remote endpoint address: 192.9.200.0
Enter remote load/dump host address [default 192.9.200.88]::
Using remote endpoint address: 192.9.200.88
Should this interface be used for memory dumps? (y/n) [y]::
Enter the baud rate [9600]::
Enter the number of stop bits (1,1.5,2) [1]::
Enter the parity (none,even,odd) [none]::
NOTE
Pressing CONTROL + C interrupts the slip command; the parameters remain unchanged until the command completes normally.
3.2.17
stats
The stats command displays current network statistics gathered by the
ROM. Use stats along with the boot command to help isolate problems.
Table 3-3 describes the network statistics displayed by the stats command. The syntax is: stats [-slip]
3-24 Micro-CS Installation Guide
Commands
The stats command display looks like this: monitor:: stats
Ethernet Statistics
Frames Received: 398 Frames Sent: 3
CRC Errors: 0 Carrier Sense Losses: 0
Alignment Errors: 0 Clear to Send Losses: 0
Resource Drops: 0 Collisions Detected: 0
Bus Wait Drops: 0 Excessive Collision Losses 0
Bad Types/Lengths: 0
Statistic
Frames Received
CRC Errors
Alignment Errors
Resource Drops
Bus Wait Drops
Bad Types/
Lengths
Frames Sent
Carrier Sense
Losses
Table 3-3 . Network Statistics
Description
The number of frames received.
The number of CRC checksum errors detected.
The number of frames received misaligned with a CRC error.
The number of packets dropped because the ROM code could not buffer them quickly enough. The ROM code cannot always handle back-to-back incoming packets. The Micro-CS accepts the first response it receives and drops all others. Dropped packets are normal.
The number of packets dropped due to waiting too long for a bus to become available.
The number of unknown packet types if Ethernet IP encapsulation is being used. The number of packets with illegal lengths if IEEE 802.2/802.3 IP encapsulation is being used.
The number of frames sent.
The number of times packets could not be transmitted because the Micro-CS lost the Carrier Sense signal – usually the result of excessive traffic on the Ethernet.
Micro-CS Installation Guide 3-25
Chapter 3: ROM Monitor Commands
Table 3-3 . Network Statistics (Continued)
Statistic
Clear to Send
Losses
Collisions Detected
Excessive Collision
Losses
Description
The number of times packets could not be transmitted because the Micro-CS lost the Clear to Send signal – usually the result of excessive traffic.
The number of times the Micro-CS had to retry transmissions automatically – usually the result of normal Ethernet traffic. These retries do not cause the
boot command to display ‘‘*.”
The number of times the Micro-CS could not transmit packets because there were too many collisions – usually the result of excessive traffic on the Ethernet.
The boot command displays these retries as “*.”
3-26 Micro-CS Installation Guide
CHAPTER 4
TROUBLESHOOTING PROCEDURES
4.1
GENERAL
The Micro-CS’s front panel displays 4 system indicators and 9 status indicators. The system indicators are labeled STATUS, NET, ATTN, and SETUP. The status indicators are labeled 1 through 7, M(odem), and
INT.
The system indicators provide information about normal operations and about problems that occur. Use these indicators and the ROM Monitor commands to diagnose problems.
The status indicators display port activity during normal operations; each indicator supports 1 port.
During power-up and booting it is more complicated to diagnose problems because they can originate in the Micro-CS or the load server host. However, the indicators provide both a progress report and an error display to assist you in troubleshooting.
4.2
POWER-UP AND BOOT PROCEDURES
The Micro-CS has two modes of operation: normal and SETUP. Normal mode is the standard operational mode. Set Up mode provides access to the ROM Monitor commands. Pressing the SETUP switch on the front panel within 3 seconds of powering–up puts the Micro-CS into SETUP mode. When the Micro-CS is in SETUP mode the SETUP indicator lights.
During the power-up and boot sequence the Micro-CS performs a set of diagnostics. The system indicators display the diagnostics status. The
Micro-CS stops when it detects one of two error conditions (see Table
4-2). The pattern of the system indicators identifies the error condition.
4.2.1
Normal Mode
Upon power-up or reset the Micro-CS enters normal mode. The following subsections describe both the possible error and error-free conditions that can occur during power-up and booting in normal mode.
Micro-CS Installation Guide 4-1
Chapter 4: Troubleshooting Procedures
4.2.1.1
Normal Mode Error-free Sequence
Table 4-1 summarizes the indicator display sequences during error-free power-up in normal mode.
Key:
Table 4-1 Normal Mode Error-free Indicator States
Activity
N1: Indicators OK
N2: Hardware OK
STAT green
ATTN amber
● ●
●
NET green
●
✕ ■
●
= On continuously
✕
= Off
■
= Flashing irregularly
◆
= Flashing regularly (about 1Hz)
Activity N1: Testing Indicators
All front panel indicators light for a few seconds then all turn off, confirming that all indicators are operational.
Activity N2: Testing the Hardware
During the power-up sequence the Micro-CS runs a series of self-test diagnostics. These diagnostics test internal hardware functions. If a test fails, the ATTN and STATUS LEDs flash and an error message is displayed, if the console port is selected. The NET indicator flashes during the power-up self-tests. After the tests are complete, only the
STATUS LED stays on.
4.2.1.2
Normal Mode Error States
Table 4-2 shows the state of the indicators when an error occurs at given stages of the start-up process. For example, if the Micro-CS fails during the testing hardware state (N2), the error condition is hardware failure
NE2. A description of possible causes and solutions for each error condition follows Table 4-2.
4-2 Micro-CS Installation Guide
Power-Up and Boot Procedures
Table 4-2 Normal Mode Error Indicator States
Activity
NE2: Hardware failure
STATUS green
◆
ATTN amber
◆
Key:
NE5: Booted wrong image
● ◆
●
= On continuously
✕
= Off
■
= Flashing irregularly
◆
= Flashing regularly (about 1Hz)
NET green
✕
✕
Activity NE2: Hardware Failure
The ROM diagnostics detected a Micro-CS hardware problem requiring service. Call technical support.
Activity NE5: Booted Wrong Image
The Micro-CS has just loaded an inappropriate image. Pressing the
SETUP switch for approximately 3 seconds to generate a reset clears this error. The Micro-CS loads inappropriate images if one of the following operator errors occur:
• Configuring the Micro-CS with an incorrect file name or renaming or copying the image file to the wrong name.
• Supplying the wrong name to any of the boot commands (na boot,
dumpboot, or the superuser CLI boot).
If you are uncertain as to why the Micro-CS booted the wrong image, enter Set Up mode and issue an image -d command. This command shows which host file the Micro-CS is trying to load.
SETUP Mode
Pressing the SETUP switch within 3 seconds of either a reset or cycling on power puts the Micro-CS into Set Up mode. The SETUP indicator is on after pressing the SETUP switch.
Micro-CS Installation Guide 4-3
Chapter 4: Troubleshooting Procedures
4.2.1.3
SETUP Mode Error-Free Sequence
Table 4-3 summarizes the indicator sequences that display in SETUP mode during an error-free start-up. A description of each sequence follows Table 4-3.
Table 4-3 SETUP Mode Error-Free Indicator States
Key:
Activity
T1: Testing Indicators
STATUS green
●
ATTN amber
NET green
● ●
T2: Testing hardware
T3: At monitor prompt
●
●
✕
●
■
■
●
= On continuously
✕
= Off
■
= Flashing irregularly
◆
= Flashing regularly (about 1Hz)
Activity T1: Testing Indicators
All front panel indicators except the non-selected segment LEDs, light for a few seconds, then all indicators turn off. This sequence confirms that all indicators are operational. At this point the Micro-CS is in normal mode.
Press the SETUP switch to put the Micro-CS into monitor mode.
Activity T2: Testing the Hardware
During power-up the Micro-CS runs self-tests that execute CPU diagnostics, ROM and E2 PROM, flash checksums, refresh, internal serial port and LAN loopbacks, and RAM tests. The NET indicator flashes during the tests. After completing the power-up self-tests the
STATUS indicator remains on.
Activity T3: At the Monitor Prompt
When the STAT and ATTN indicators are on, the ROM Monitor prompt displays on the console terminal. Enter the boot command at the prompt.
If you did not enter a file name with the command, a prompt asks you for one.
4-4 Micro-CS Installation Guide
Boot Failures
4.2.1.4
Set Up Mode Error States
Table 4-4 describes the state of the indicators if errors occur at different stages of the start-up process. For example, if the Micro-CS fails while testing the hardware (state T2), the error condition is hardware failure
TE2. A description of each error condition follows Table 4-4.
Table 4-4 SETUP Mode Error Indicator States
Key:
Activity
TE2: Hardware failure
TE7: Booted wrong image
STATUS green
◆
●
ATTN amber
◆
◆
●
= On continuously
✕
= Off
■
= Flashing irregularly
◆
= Flashing regularly (about 1Hz)
NET green
✕
✕
Activity TE2: Hardware Failure
The ROM diagnostics detected a Micro-CS hardware problem requiring service. Call technical support.
Activity TE7: Booted Wrong Image
The Micro-CS loaded an inappropriate image. Pressing the SETUP switch approximately 3 seconds to generate a reset clears this error. The
Micro-CS loads inappropriate images if one of the following operator errors occurs:
• Configuring the Micro-CS with an incorrect file name or renaming or copying the image file to the wrong name.
• Supplying the wrong name to the boot command.
4.3
BOOT FAILURES
The procedures for troubleshooting a power-up failure established that
• the hardware is functional
• the Ethernet interface is functional
• the Micro-CS can communicate with the Ethernet
If the Micro-CS still is not booted, you must pinpoint the problem. The boot error report can help in this process.
Micro-CS Installation Guide 4-5
Chapter 4: Troubleshooting Procedures
NOTE
The Micro-CS generates a boot error report only if it opens the boot file and an error occurs during the boot process.
Generally, two problems cause boot failures: the Micro-CS is not configured properly, or the load server host is not responding. The
Micro-CS requests a boot either from a pre-defined load host, or by broadcasting its boot request. When a host responds, the Micro-CS loads its operational code.
The Micro-CS requires setting certain configuration parameters. Enter these parameters with ROM Monitor commands for the initial boot sequence. See Chapter 3 for more information on these commands.
If the problem is a non-responsive host the boot error report displays that information under the Rsp T/O’s: field. This field indicates that the
Micro-CS timed out while waiting for a response to its boot request; if this field is empty, check the Micro-CS’s configuration parameters.
Boot Error Report
If an error occurs, a boot error report is generated only if the Micro-CS has opened the boot file. The report uses the following format:
BOOT ERROR REPORT (for BFS files only)
Boot attempt from host nn.nn.nn.nn:
Errors from Last Open Request:
0 ARP errors 0 ERPC layer errors 0 Aborts rx’d
Errors from Last Read Request:
0 Msgs w/ wrong size 0 ERPC layer errors 0 Aborts rxd
Errors from Last ERPC Layer Invocation:
0 H/W errors 1 Msgs from wrong host 0 Rsp T/O’s 0 Msgs of wrong type
NOTE
TFTP error reporting complies with the standard, pre-defined
TFTP error codes.
The Micro-CS generates a boot error report for the Internet address from which it tried and failed to boot. Table 4-5 describes the Errors from Last
Open Request; Table 4-6 describes the Errors from Last Read Request; and Table 4-7 describes the Errors from Last ERPC Layer Invocation.
4-6 Micro-CS Installation Guide
Boot Failures
The error count pinpoints the error that caused the boot failure. For example, if the boot failed during a Read Request due to excessive
Expedited Remote Procedure Call (ERPC) layer errors, the Errors from
Last ERPC Layer Invocation lists only errors that occurred during the failed Read Request. The report does not list errors that occurred during any other Read Request or during the Open Request.
The Open Request and the Read Request layers communicate with the block file server (BFS) on the host. The ERPC layer resides below the
Open Request and the Read Request layers. It is responsible for sending a given message to a specific host UDP port and for receiving the correct response to that message from the port.
ARP errors
Aborts rx’d
Table 4-5 Errors from Last Open Request
ERPC layer errors
Address Resolution Protocol (ARP) errors indicate that the Micro-CS is configured to boot from a specified host, but the host would not transmit its Ethernet address to the Micro-CS. Possibly, the Micro-CS configuration includes the wrong IP encapsulation.
See Errors from Last ERPC Layer Invocation below.
The host’s BFS transmitted an abort in response to the
Micro-CS’s Open Request. This often means that the requested file does not exist on that server. Run
erpcd -D on the host to obtain more information.
Aborts rx’d
Table 4-6 Errors from Last Read Request
Msgs with wrong size
ERPC layer errors
The correct host responded to the Read Request, but the data size is incorrect.
See Errors from Last ERPC Layer Invocation below.
The host’s BFS transmitted an abort in response to the
Micro-CS’s Read Request. Run erpcd -D on the host to obtain more information.
Micro-CS Installation Guide 4-7
Chapter 4: Troubleshooting Procedures
H/W errors
Msgs from wrong host
Rsp T/O’s
Table 4-7 Errors from Last ERPC Layer Invocation
Msgs of wrong type
The Micro-CS sensed a hardware error during message transmission or reception. This error indicates a fault with the Micro-CS network interface. Use the net command to isolate the problem (see Chapter 3).
The Micro-CS received a message from an incorrect host. This indicates that the
Micro-CS received, and ignored, an unsolicited packet.
The Micro-CS never received a correctly formatted response from the correct host, or any response from any load server hosts.
The correct host sent a message to the
Micro-CS, but the message was not a correctly formatted response to the transmitted request.
4.4
CORRECTING MICRO-CS PARAMETERS
The following parameters must accurately reflect both the Micro-CS and the network environment in which it operates:
• Verify the Micro-CS’s Internet address using the addr command.
• If your network configuration does not support the factory defaults, verify the following parameters using the addr command:
The broadcast address.
The subnet mask.
The load/dump gateway address (which must be specified if the preferred load server host is located on another network or subnet).
The IP encapsulation type. Many systems have hardware Ethernet interfaces that are IEEE 802.3 compliant but very few actually do
802.3 IP packet encapsulation. Use the default, Ethernet, unless you know absolutely that your LAN does 802.2/802.3 IP packet encapsulation.
4-8 Micro-CS Installation Guide
Load Server Host Not Responding
• Unless otherwise stated, if you are using a SLIP interface to boot the
Micro-CS, verify the following using the slip command:
The port is configured as a SLIP interface.
The Internet address for the SLIP network interface.
The Internet address for the remote end of the SLIP connection.
The Internet address for the load/dump host (this must be specified if the remote end is a gateway and not a load host).
The SLIP network interface is included in the load/dump interface list (use the sequence command).
Both the name of the image file containing the Micro-CS’s software and the address of the preferred load server host can be defaulted. If the value for the image name is incorrect, the Micro-CS cannot boot. Correct the name using the image command. If the address for the preferred load server host is incorrect, the boot takes longer, since the Micro-CS has to broadcast for a host. Correct the load host’s address using the addr command.
Confirm that the Micro-CS boot parameters are correct by using the appropriate ROM Monitor commands. Modify any boot parameters that are incorrect or missing. Boot the Micro-CS either by entering the boot command at the console, or by pressing the SETUP switch approximately
3 seconds to generate a reset, followed by an automatic boot.
4.5
LOAD SERVER HOST NOT RESPONDING
The Micro-CS can boot from one of four types of hosts acting as a load server host:
• A UNIX host on the local area network.
• A UNIX host at the end of a SLIP interface.
• Another Micro-CS.
• Any host (UNIX or non-UNIX, using tftp).
The following sections discuss troubleshooting for each of these load server hosts.
Micro-CS Installation Guide 4-9
Chapter 4: Troubleshooting Procedures
UNIX Host on the LAN
When troubleshooting a UNIX host on the LAN, make sure
• The host is booted and functioning properly.
• The host can communicate with other network nodes using standard
UNIX networking features and utilities.
• All Micro-CS software is installed properly on the host. (See the
CSMIM2 Installation Notes.)
• The erpcd daemon or tftp server, which loads the operational image to the Micro-CS, is running.
In SETUP mode, Micro-CS displays the boot progress report on the console.
• To place the Micro-CS into SETUP mode, press the SETUP switch after a reset and wait for monitor prompt.
• To place erpcd on the load server host into test mode, kill the erpcd program (requires superuser privileges) and restart it using the -D option:
# /etc/erpcd -D
When the Micro-CS boots in SETUP mode the console displays the load server host’s Internet address and indicates whether it receives a response to its Open File Request and to any of its Read File Requests.
The host’s progress report indicates receipt of any File Server Requests and its responses to such requests. The host displays erpc_return 0 if it successfully receives a request and is sending out an affirmative response.
If any Micro-CS related files are missing or cannot be installed, contact technical support.
4-10 Micro-CS Installation Guide
Load Server Host Not Responding
UNIX Host on a SLIP Interface
When troubleshooting a UNIX host at the end of a SLIP network interface, make sure
• The host is booted and functioning properly.
• The SLIP link is connected correctly.
• The Internet addresses are correct for both sides of the SLIP link.
• All Micro-CS software is installed properly on the host. See the
CSMIM2 Installation Notes.
• The erpcd daemon or tftp server, which loads the operational image to the Micro-CS, is running.
A PC host running the XENIX operating system has both the erpcd and
slipd daemons (provided with the distribution and installed in the file
/etc) running in the background on the PC. Set the Micro-CS and the
erpcd on the load host into Set Up mode:
• For the Micro-CS, press SETUP following a reset and wait for the monitor prompt.
• For erpcd on the load server host, as superuser, kill the erpcd program and restart it using the -D option:
# /etc/erpcd -D
Another Micro-CS
When troubleshooting a Micro-CS configured as a load server host
• Use the CLI telnet command to access the unit and verify that it is up and running.
• Communicate with the unit on the Ethernet using the superuser CLI
ping command. Ping is also available through the monitor command.
• Verify the unit’s configuration using na or the admin command.
The CSMIM Network Administrator’s Guide provides more information on these commands.
Micro-CS Installation Guide 4-11
Chapter 4: Troubleshooting Procedures
Be aware that the Micro-CS can only boot another Micro-CS that has the same configuration. Thus, a Micro-CS with only 2MB of RAM and no option keys enabled cannot boot a Micro-CS with 4 MB of RAM and the
IPX option enabled.
A Micro-CS that has been reconfigured as a load server host, but not rebooted, cannot boot another Micro-CS on the network. Rebooting the
Micro-CS load server host ensures that the parameters are set.
4.6
MICRO-CS DUMPS
The Micro-CS dumps its memory image to a host running load server software when certain software or hardware events occur. Events that trigger Micro-CS dumps are
• Non-recoverable hardware or software errors.
• Software fails to reset the Micro-CS’s watchdog timer.
• Software fails one or more internal consistency checks.
• Hardware detects an internal fault.
NOTE
Dump files are generated for use by technical support personnel only.
Table 4-8 Indicator States during a Dump
Activity
Dump
STATUS green
●
ATTN amber
●
NET green
■
●
= On continuously
■
= Flashing irregularly Key:
The Micro-CS sends a dump file to a preferred load dump host. If you do not define this host by specifying an address, the Micro-CS broadcasts a request and dumps to the first host running erpcd daemon that responds.
The dump creates a file in the dump host’s directory, named
/usr/spool/erpcd/bfs, and assigns a unique file name for each Micro-CS but not for each crash dump. For each dump, the Micro-CS overwrites the existing file.
4-12 Micro-CS Installation Guide
Micro-CS Dumps
The assigned name depends on the number of characters per file name that the dump host supports. For hosts supporting file names longer than
14 characters (e.g., BSD hosts), dump files are named dump.addr. The file extension addr is the Micro-CS’s Internet address.
For hosts that limit file names to 14 characters (e.g., System V hosts), a dump creates two additional directories under /usr/spool/erpcd/bfs. The name of the first directory is dump; the second directory uses the
Micro-CS’s Internet network address as its name. The dump file uses the
Micro-CS’s Internet host address as its name.
Each dump file contains a complete image of the Micro-CS RAM memory and hardware state. The amount of space required for a dump file varies according to the port configuration. The ROM Monitor config command displays the amount of memory for the Micro-CS. Table 4-9 shows sample dump file names. All pathnames are relative to the file
/usr/spool/erpcd/bfs.
Micro-CS
Address
63.0.0.75
131.140.23.1
195.46.2.15
Table 4-9 Dump File Naming Conventions
Network
Address
BSD
Filename
System V
Pathname
63
131.140
195.46.2
dump.63.0.0.75
dump/63/0.0.75
dump.131.140.23.1
dump/131.140/23.1
dump.195.46.2.15
dump/195.46.2/15
NOTE
The tftp dump names are user-defined. If a name is not specified, the Micro-CS uses the bfs convention.
Micro-CS Installation Guide 4-13
Chapter 4: Troubleshooting Procedures
4-14 Micro-CS Installation Guide
APPENDIX A
PORT PIN/SIGNAL ALLOCATIONS
A.1
GENERAL
This appendix identifies the signals and the associated pins used by the following Micro-CS ports:
• Console
• Serial
NOTE
Port 1 of the Micro-CS serves as a console port only during Set
Up. At all other times, port 1 acts as a serial port.
A.2
CONSOLE PORT
When the Micro-CS is in SETUP mode, port 1 becomes the console port.
The cable shipped with the Annex Communication Software can be used as the console cable.
Table 1-1 RJ45 Console Port Pin/Signal Allocations
RJ45 Pin
3
4
5
1
2
6
7
8
Signal
RTS
DTR
TXD
CD
RXD
GND
DSR
CTS
Micro-CS Installation Guide A-1
Appendix A: Port Pin/Signal Allocations
1 8
Front view
Figure A-1 RJ45 Console Port Receptacle
A.3
SERIAL PORT
The following table provides pinout information for the Micro-CS serial ports.
Table A-2 RJ45 Serial Port Pin/Signal Allocations
RJ45 Pin Signal
5
6
7
8
1
2
3
4
RTS
DTR
TXD
DCD
RXD
GND
DSR
CTS
A.4
LAN NETWORK PORT
There are two ways to connect to the network with the Micro-CS:
Through an RJ45 connector to the MicroMMAC internal AUI, or through an RJ45 mounted on the front panel.
A-2 Micro-CS Installation Guide
Table A-3 Internal AUI RJ45
Pin Signal
7
8
5
6
3
4
1
2
DI+
DI-
DO+
DO-
CI+
CI-
LINKUP
LINKDN
Direction
IN
IN
OUT
OUT
IN
IN
IN
OUT
Signal Type
Data+
Data-
Data+
Data-
Collision
Collision
Control
Control
Modem Port
Pin
6
7
4
5
8
1
2
3
Table A-4 Front Panel 10BASE-T RJ45
Signal
TD+
TD-
RD+
Direction
OUT
OUT
IN
Signal Type
Data+
Data-
Data+
RDIN Data-
A.5
MODEM PORT
The modem network interface supports an RJ11 connector with the following pinout:
Table A-5 Modem Port Pinouts
RJ11 Pin
1
2
Signal
A
Ring
Micro-CS Installation Guide A-3
Appendix A: Port Pin/Signal Allocations
Table A-5 Modem Port Pinouts
RJ11 Pin Signal
3
4
Tip
A1
A-4 Micro-CS Installation Guide
APPENDIX B
CONNECTORS
B.1
GENERAL
This appendix describes the wiring for the following connectors:
• DTE (Cabletron part number 9372074) for DB25 female
• DTE (Cabletron part number 9372082) for DB25 male
• DTE (Cabletron part number 9372076) for DB9 female
• DCE (Cabletron part number 9372083) for DB25 female
• DCE (Cabletron part number 9372075) for DB25 male
7
8
5
6
1
2
3
4
RJ45
Pin
Signal
RTS
DTR
TxD
DCD
RxD
GND
DSR
CTS
Direction
OUT
OUT
OUT
IN
IN
GND
IN
IN
DTE
DB25
DCE
DB25
2
7
20
4
5 4
8 + 6 20
3
20
2
8
6
5
3
7
DTE
DB9
4
7
3
5
2
4
8
6+1
MMJ
(RS423)
6 DSR
5 RXD
1 DTR
2 TXD
3+4 GND
Use these adapters with Cabletron part number 9360005-X or a straight-through cable.
Part Numbers 9360005-X, 9372074, and 9372076 are shipped with the software package.
Micro-CS Installation Guide B-1
Appendix B: Connectors
B.2
ADDITIONAL CABLETRON CABLES AND
CONNECTORS
Micro-CS to Micro-CS Rollover Cable: part number 9360167-XX
Micro-CS to RJ45 Console Connector: part number 9360166-XX
Micro-CS to DB9 Console Connector: part number 9372087
B-2 Micro-CS Installation Guide
APPENDIX C
FLASH UPGRADE INSTRUCTIONS
C.1
GENERAL
The Micro-CS flash upgrade kit allows you to add flash memory to your existing Micro-CS by adding a flash daughter card. These installation instructions provide the following:
• Kit contents
• Required tools
• Installation instructions
C.2
CONTENTS OF THE KIT
Table C-1 lists the contents of the Micro-CS upgrade kit.
4
5
6
7
1
2
3
Item
Table C-1 Micro-CS Upgrade Kit Contents
Qty.
Description/Part No.
1
1
1
1
1
2
1
Flash Daughter Card
Standoff, 1/2”, nylon
Retainer, snap in
Disposable wrist strap
9372074 25 pin DTE female
9372076 9 pin DTE female
9360005-10 10’ cable
C.3
REQUIRED TOOLS
The only required tool is a Phillips screwdriver.
Micro-CS Installation Guide C-1
Appendix C: Flash Upgrade Instructions
C.4
INSTALLATION PROCEDURE
!
CAUTION
Observe all anti-static procedures when handling electronic equipment.
C.4.1
Installing the Flash Daughter Card
1.
Install the two (2) snap-in nylon standoffs through the holes in each corner of the flash daughter card.
2.
Align the connector of the flash daughter card with the J12 connector on the Micro-CS (see Figure C-1) and seat firmly ensuring that the nylon standoffs snap into their mating holes on the board.
Nylon standoffs
Snap In Retainer
FLASH CARD
J12
Figure C-1 Flash Card Installation
Please note that although the hardware configuration of the FLASH card is the same for the Micro-CS, CSMIM2, and MODMIM, the image is not.
The Micro-CS uses “oper.52.enet” and the CSMIM2/MODMIM use
“oper.42.enet”. It is possible to use the FLASH card on either platform, but the image loaded must be the correct one for the application.
C-2 Micro-CS Installation Guide
Installation Procedure
C.4.2
Changing the Boot Method
1.
Attach a VT-100 type console terminal to port 1. Set this terminal to
9600, no parity, 8 data, 1 stop.
2.
Power-up the MicroMMAC with the Micro-CS installed. Immediately following the LED test (all turn on and then off), depress the SETUP switch on the Micro-CS using a thin tool and note that the SETUP indicator turns on.
3.
After approximately one minute the console displays the monitor prompt (monitor::). At this prompt, enter:
seq <cr>
4.
The console responds with the prompt
Enter interface sequence {net}::
5.
At this prompt, enter:
self <cr>
6.
Now check for a bootable image in the flash PROM. At the monitor prompt, enter:
image -d <cr>
7.
The last line of the response should read:
SELF image name: “oper.52.enet”
8.
If this name is missing, the Micro-CS did not find a bootable image in the newly-installed Flash PROM. Contact Technical Support for assistance.
9.
At the monitor prompt, execute the boot command by entering:
boot <cr>
NOTE
In the unlikely event that you should ever have to return the
Micro-CS to Cabletron for repair, please remove and save the flash upgrade for use on the replacement board supplied by
Cabletron. If you are unable to remove the Flash, contact your
Cabletron Customer Support Representative so that they can document that the board was returned with the Flash still installed.
Micro-CS Installation Guide C-3
Appendix C: Flash Upgrade Instructions
C-4 Micro-CS Installation Guide
APPENDIX D
MICRO-CS UPGRADE INSTALLATION
D.1
GENERAL
In most cases, the Micro-CS will come factory installed and preconfigured. However, because it is also available as an upgrade, this section details the installation of a Micro-CS into a MicroMMAC. See the appropriate appendices for the installation of additional memory and/or
Flash upgrades. After completing the physical installation, please return to Chapter 2 for setup information.
D.2
LOCATING THE CONFIGURATION JUMPERS
The Micro-CS has 5 jumpers. Figure E-1 shows the locations of the jumpers. Please note that the pins on the Micro-CS are to be read from left to right.
J18
J16
J25
J10
J2
1
2
3
1 2 3 1 2 3
SIMM CARDS
Figure D-1 Jumper Locations
Micro-CS Installation Guide D-1
Appendix D: Micro-CS Upgrade Installation
The configuration of your Micro-CS will determine how the jumpers should be set. Table E-1 shows possible configurations and jumper positions.
Jumper
J2
J10
J16
J18
J25
Position
1-2
2-3
1-2
2-3
1-2
2-3
1-2
2-3
Table 4-1 Jumper Configuration
Description
SIMM upgrade has been installed
SIMMs are not present
Modem card is not installed
Modem is installed
No jumper should be present. DO NOT use jumper.
Installed SIMMs are 4Mx8
Installed SIMMs are 1Mx8, OR if no SIMMS are present
Modem uses ROM for configuration data The modem uses Power On and ATZ Reset Software factory default settings from read only memory
(ROM). If the user uses the modem's dial security password (not recommended) and forgets the password, then this jumper setting is used to regain access to the modem, and then change the password.
Modem uses NVRAM for configuration data
(default)The modem uses Power On and ATZ
Reset Software defaults from the user configurable nonvolatile memory (NVRAM). This is the default and preferred setting which allows normal operation of the Micro-CS
D.3
REQUIRED TOOLS
The only required tool is a phillips screwdriver.
D-2 Micro-CS Installation Guide
Item
7
8
9
10
3
4
5
6
1
2
Installation Procedure
D.4
INSTALLATION PROCEDURE
Please read all the installation instructions prior to performing the install to determine the correct steps for your configuration. Since the
MicroMMAC can be configured with 24 ports, 2 EPIMs and a BRIM, some components may have to be removed in order to facilitate installation of the Micro-CS.
!
CAUTION
Observe all antistatic precautions when handling electronic components.
Table 4-2 Micro-CS Upgrade Kit Contents
Qty.
1
4
4
1
1
4
1
1
1
1
Description/Part No.
Micro-CS / 8910394
Wrist Strap / (part of 8910394)
Overlay Label / (part of 8910394)
1” Stand off (only 2 needed) / 8020076
6 inch cable / 9360171-6”
EPIM-3PS and manual
Micro-CS User’s Guide (this manual) / 9031431
Screw, 6-32x5/16” (only 2 needed)
Washer, flat #6 (only 2 needed)
FCC Compliance Label
Micro-CS Installation Guide D-3
Appendix D: Micro-CS Upgrade Installation
D.5
INSTALLING THE MICRO-CS UPGRADE
Ensure that the power cord is removed from the unit before removing the cover. Do not remove any screws other than those necessary for this installation. Failure to follow these warnings may result in the presence of an electrical hazard.
1.
Remove the cover from the MicroMMAC.
Chassis Cover
Chassis
BRIM Slot
Cover Screw (7)
NVRAM Switch
Figure D-2 : Cover Removal
Depending on the configuration of your MicroMMAC, you may have to remove certain components at this time.
2.
Remove the upper port cutout blank, or the 12 port daughter card from the MicroMMAC.
D-4 Micro-CS Installation Guide
Installing the Micro-CS Upgrade
MicroMMAC TOP VIEW screws
Blank
Front Panel screws
Figure D-3: Screw Locations a.
Remove screws securing the blank or the daughterboard to the motherboard. If you are removing the blank there are two screws.
If you are removing the daughterboard, there are four screws (see
Figure D-3).
b.
For the MicroMMAC-22E you will have to remove the two screws on either side of JP2 and replace with 1” standoffs.
3.
Install the EPIM-3PS with the RJ45 cable connected to it, into slot 1 of the MicroMMAC now.
4.
Carefully align the pins on the Micro-CS with the connector JP2 on the
MicroMMAC (see Figure D-4).
5.
Press the Micro-CS into place on the MicroMMAC.
Micro-CS Installation Guide D-5
Appendix D: Micro-CS Upgrade Installation
J3
Figure D-4 : Micro-CS Installation
6.
Connect the RJ45 cable from the EPIM-3PS (or the BRIM) to the J3 jack on the Micro-CS.
7.
Check the alignment of the ports on the front panel.
8.
Insert screws through holes in the Micro-CS to the standoffs in the
MicroMMAC and tighten.
9.
Locate the mylar replacement faceplate for the MicroMMAC and
carefully attach it now.
TIP
The mylar faceplate for the MicroMMAC is very sticky. You may only have one chance to get it on right. It is easier if you start from the right side of the MicroMMAC and align the corners.
Ensure that the cover is in place before connecting the power cord.
10.
Attach FCC Compliance Label to the rear of the MicroMMAC chassis.
11.
Replace the cover on the MicroMMAC, and apply power.
Please return to Chapter 2 for information regarding Setup, Commands, and Software Installation.
D-6 Micro-CS Installation Guide
A addr command 3-3 examples 3-4
Auto-initializing the ROMs 2-6
B boot command 3-6 examples 3-10 boot error report 4-6 field descriptions 4-6 boot failures correcting boot parameters 4-8 error report 4-6 file server hosts not responding
CSMIM 4-11 over SLIP 4-11
UNIX 4-10 troubleshooting procedures 4-5 boot -l command 3-9 booting sequence 4-1
BOOTP 2-6 broadcast address setting 3-5
C
Cables maximum lengths 2-2 cables and connectors B-1 config command 3-11
Configuration Jumpers D-1
Connecting CSMIM to console 2-1 to serial devices 2-2
Console Port A-1
Console port description of 1-8 console port 1-8, 2-1
Console terminal description 2-1
Micro-CS Installation Guide
INDEX
console-baud command 3-11
D dumps 4-12 files 4-12
E environmental requirements 1-9 erase command 3-13
Ethernet transceiver loopback test 3-17
Ethernet address displaying 3-3 during power-up 2-5
F
FCC Notice ii front panel description of 1-6
H hardware configuration displaying 3-11 during power-up 2-4 help command 3-14
I
IC Notice iv image command 3-14, 3-15 examples 3-14, 3-15, 3-16, 3-17,
3-18 image -d command 3-16 image name default 3-6, 3-14 indicator states normal mode error states 4-2
Industry Canada Certification
Number iii initial boot parameters setting addresses 3-3
-1
Index
Installation D-1
Installation Procedure D-3
Internet address setting 3-5
IP encapsulation setting 3-5
J jumper positions D-2
L lat -d command 3-16 lat_key command 3-16
Load Number iii load/dump gateway setting 3-5
M manual booting description 3-6
Micro-CS upgrade D-1 mop command 3-17 mop -d command 3-17
N net command 3-17 normal mode error indicator states 4-2 error-free sequence 4-2 power-up and booting sequence 4-1 power-up error states 4-2
O option_key command 3-18 option_key -d command 3-18
P ping command 3-18 port pin/signal allocations A-1 port upgrade instructions 2-1, C-1 ports command 3-19 power-up applying power 2-3 failures during 2-4 in normal mode 4-1 in SETUP mode 4-3 instructions 2-3 running self-tests 2-4 self-testing procedures during 2-3 sequence 4-1 setting to test mode 2-3 power-up and boot sequence 4-1 preferred load host setting 3-5
R
RARP 2-6
ROM Monitor command syntax 3-1 commands 3-1 description of 1-4 list of commands 3-1
S sequence command 3-21 examples 3-21
Serial Devices 2-2 setting boot sequence 3-21 broadcast address 3-5
Internet address 3-5
IP encapsulation 3-5 load/dump gateway address 3-5 preferred load host address 3-5
SLIP parameters 3-22 subnet mask 3-5
SETUP Mode 4-3
SETUP mode error-free power-up sequence 4-4 size 1-9
SLIP parameters 3-23 slip command 3-22 example 3-24
-2 Micro-CS Installation Guide
Index software installation executing boot command 2-9 procedures 2-8 setting boot sequence 2-9 setting initial boot parameters 2-8 setting Internet address 2-8 setting SLIP parameters 2-9 stats command 3-24 example 3-25 status indicators description of 1-7 subnet mask setting 3-5
System Description 1-4
T test
Ethernet transceiver loopback 3-17 printer port 3-19 serial line ports 3-19 test mode entering 4-3 entering during power-up 2-3 power-up and booting sequence 4-3 power-up error states 4-5
Test switch 1-7
TFTP 3-8 troubleshooting during power-up and booting 4-1 procedures 4-1
U
Upgrades
MicroCS 2-1
Modem 1-4
Micro-CS Installation Guide -3
Index
-4 Micro-CS Installation Guide
POWER SUPPLY CORD
The mains cord used with this equipment must be a 2 conductor plus ground type with minimum 0.75 mm square conductors and must incorporate a standard IEC appliance coupler on one end and a mains plug on the other end which is suitable for the use and application of the product and that is approved for use in the country of application.
GERMAN:
Die Netzleitung, die mit diesem Geraet benuetzt wird, soll einen zwei Leiter mit
Erdleiter haben, wobei die Leiter mindestens 0.75 mm sind, mit einer normalen
IEC Geraetesteckdose an einem Ende und einem Geraetestecker am anderen Ende versehen sind, der fuer den Gebrauch und die Anwendung des Geraetes geeignet und der zum Benuetzen im Lande der Anwendung anerkannt ist.
SPANISH:
El cable principal de la red eléctrica utilizado con este equipo debe tener 2 conductores y 1 toma de tierra con un mínimo de 0.75 mm2 cada uno y necesita tener un aparato de acoplamiento standard IEC en un extremo y un enchufe para el cable principal de la red eléctrica en el otro extremo, lo cual sea adecuado para el uso y applicación del producto y lo cual sea aprobado para uso en el pais de applicación.
FRENCH:
Le cordon d' alimentation reliant cet appareil au secteur doit obligatoirement avoir deux fils conducteurs de 0.75 mm2 minimum et un fil de terre. It doit également
être équipé du côté appareil d'une fiche agrée IEC et du côte secteur, d'une prise adaptée à l'usage du produit et aux normes du pays où l'appareil est utilisé.