Broan L300 KMG Hvac Installation Guide
Add to My manuals4 Pages
Broan L300 KMG is a ceiling/wall mount вентилятор designed for continuous operation in your home. It features a powerful motor for efficient air circulation and a damper that opens and closes freely to prevent backdrafting. The вентилятор can be mounted in new or existing construction and comes with all the necessary hardware for installation. It also has a variety of mounting and wiring options for flexible placement. With its sleek design and easy-to-clean grille, the Broan L300 KMG is a great choice for any home.
advertisement
▼
Scroll to page 2
of
4
BREAN LOSONE SELECT“ VENTILATOR Ceiling/Wall Mount e 120V MODEL « L300KMG READ AND SAVE THESE INSTRUCTIONS WARNING A 77 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have guestions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent waming de- vice, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualifiec person(s) In accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting, Follow the heating equipment manufacturer's guide- ine and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted fans must always be vented to the outdoors. lo reduce the risk of fire, use only metal ductwork. . Never place a switch where It can be reached from a tub or shower. 9. This unit must be grounded. nd DA TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 1. Never leave surface units unattended at high settings. Bollovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. 2. Always turn hood ON when cooking at high heat or when cooking flaming foods. 3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. 4. Use proper pan size. Always use cookware appropriate for the size of the surface element. TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:* 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the bummer. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE HRE DEPARTMENT. . NEVER PICK UP A FLAMING PAN — You may be burned. . DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result. 4. Use an extinguisher ONLY 1í: A. You know you have a Class ABC extinguisher and you already know how to operate it. B. The fire is small and contained in the area where it started. CG. The fire department is being called. D. You can fight the fire with your back to an exit. * Based on Kitchen Fire Safety Tips published by МЕРА. 69 Го CAUTION A 1. For general ventilating use only. Do not use to exhaust hazard- ous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. Please read specification label on product for further Informa- tion and requirements. TABLE OF CONTENTS This manual Is divided into sections as follows: « “TYPICAL INSTALLATION” This section shows a common installation in new and existing, frame construction. - Mounting (new construction) - Mounting (existing construction) - Wiring - Ducting (horizontal blower discharge) « “MOUNTING OPTIONS” « “WIRING OPTIONS” -Wiring Plate Position « “DUCTING OPTIONS" - Blower Discharge Positions - Ducting (vertical blower discharge) + “USE AND CARE” « “SERVICE PARTS” « “WARRANTY” Installer: Leave this manual with the homeowner. Homeowner: Use and Care Information on page 3. BREAN TYPICAL INSTALLATION MOUNTING (New Frame Construction) 8 ROUND DUCT Mounting brackets Г | factory-shipped in position for + celling material. ADDITIONAL 1%" FRAMING CEILING JOIST DD Blower factory-shipped In horizontal discharge position. - Hl el Hl el Hl het at et Tt Be Te et er A па Ве) GRILLE —_ Install after A | Fo, EF eT ee Te Te TE Te Tw Te TE Te Tw eT Emr Tw Te eT wT Tn Belling 15 ME finished. GRILLE | — SCREW ZT shown) I Factory-shipped unit installed in new construction. MOUNTING (Existing Frame Construction) MODEL * L300KMG Page 2 [YPICAL INSTALLATION WIRING BLACK TO BLACK Л TOP / BACK OF HOUSING 2 GROUND TO WIRING PLATE WIRING — PLATE WHITE д TO — #75 White {7 120 VAC LINE INT Ventilator can be wired from outside of housing. Use UL approved connectors to wire per local codes. DUCTING (Horizontal blower discharge) 2 X 4 FRAMING (wide side down) 8" ROUND DUCT CEILING JOIST (16 centers = MOUNTING BRACKETS (Attached to opposite sides of housing & upside-down, so housing Is flush with finished ceiling) FINISHED CEILING MATERIAL GRILLE I— SCREW = ST ROOF CAP E WA | | N h \ TN | wa а" \ | CAP ROUND I E EL BOW N | к Factory-shipped unit installed in existing construction. Two ways to connect ductwork to a factory-shipped unit. IMPORTANT: Remove shipping tape from damper Hemove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork. Use duct tape to make ductwork connections secure and air-tight. Remove shipping ring from blower inlet Hemove the shipping ring from the blower inlet before operating the ventilator. BREAN MOUNTING OPTIONS 15-20 hex nuts secure mounting brackets to housing. Loosen and re-tighten or remove and replace nuts as necessary for desired mounting bracket position. e MAX. AZ = | | ——] i le— 124" — Î LE UT la— 124" —e| Mounting brackets in factory-shipped position. (Outlet parallel to joists.) (New construction) Mounting brackets flipped over and mounted to outlet sides of housing. (Outlet parallel to joists.) (Existing construction) y O a ou ll D qu Frs TS EC la — 1214" — | le— 124" — + Mounting brackets mounted Mounting brackets flipped to outlet sides of housing. over to give approx. 1” (Outlet perpendicular to joists.) more clearance. (New construction) (Outlet parallel to joists.) 10 #4' to as (New construction) —| L__ | M A 91/2" 10. 114 | AN ) _ la 1214" — la— 124" —e Mounting brackets mounted Mounting brackets flipped to top of sides of housing. over and mounted to top of (Outlet parallel to joists.) sides of housing. (New or existing construction) (Outlet parallel to joists.) (New or existing construction) WIRING OPTIONS WIRING PLATE > POSITION PAN VERTICAL POWER CABLE CONNECTION HORIZONTAL POWER CABLE CONNECTION Wiring plate mounts to side or top of housing. MODEL * L300KMG Page 3 DUCTING OPTIONS BLOWER DISCHARGE POSITIONS DUCT CONNECTOR 1 | О < JE" Te Change | 2. ' blower & | duct connector positions for vertical discharge. DUCT CONNECTOR BLOWER — Blower and duct connector in vertical discharge position. Blower and duct connector in horizontal discharge position. (Factory shipped) DUCTING (Vertical blower discharge) = DS ROOF CAP 8” ROUND DUCT — Typical ductwork connection to a ventilator converted to vertical discharge. USE AND CARE Ventilator is designed for continuous operation. If desired, it may be controlled using an on/off switch or a solid-state, variable speed control. Follow wiring instructions packed with control, and adhere to all local and state codes. and the National Electrical Code. WARNING: To reduce the risk of electric shock, disconnect from power supply before servicing. To clean grille: Use appropriate vacuum attachment or remove grille and clean with a soft cloth and mild soap or detergent. Dry grille thoroughly before reinstalling. To clean blower assembly: Remove grille, unplug blower from housing, remove blower mounting nuts, and carefully remove blower from housing. Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure blower assembly is completely dry before reinstalling. Motor is permanently lubricated. Do not oll or disassemble motor. BRAN MODEL * L300KMG Page 4 SERVICE PARTS SERVICE PARTS KEY NO. | PART NO. DESCRIPTION 1 97014726 | Housing Assembly 2 97014728 | Mounting Bracket (2 reg.) 3 97014761 | Damper Assembly 4 99150415 | Screw, 8-18 х № (12 reg)” о 98005513 | Wire Box Cover 6 99400035 | strain Relief Bushing 7 98005512 | Winng Plate 8 99150471 | Ground Screw, 10-32 Xx Ys (2 rec) 9 97014775 | Scroll Assembly 10 98009399 | Inlet Rin 11 99020273 | Blower Wheel 12 99080485 | Motor 13 99260558 | Lock Nut, 8-32 (4 rea.) 14 99250959 | Washer (4 reg )* 15 99100491 | Grommet (4 req.) 97014814 | Blower Assembly, Complete (ncludes Key Nos. 9-15) 16 99260477 | Nut, 14-20 (6 rea.) 17 97006039 | Wire Hamess 18 98009416 | Grille 19 99420470 | Grille Nut (2 req. 20 99150472 | Grille Mounting Screw (2 req.) 21 99150591 | Screw, 10-16 x 7/8 (4 reg.) Order replacement parts by PART NO. - not by KEY NO. * Standard hardware - may be purchased locally. 13 \ № 7), | SLAs » ASSEMBLY WARRANTY BROAN-NUTONE ONE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in matenals or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INGLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MER- CHANTAEILITY OR FITNESS FOR A PARTICULAR FURFOSE. Dring this one-year period, Broan-Nu Tone will, at its option, repair or replace, without charge, any product or part which 15 found to be defective under normal use and ser- vice. THIS WARRANTY DOES NOT EXTEND TO FLUORESGENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary io recommended installation instructions. The duration of an implied warranty Is limited to the one-year penod as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE"S OBLIGATION TO REPAIR OR REFPLAGE, AT BROAN-NUTONE'S OPTION, SHALL BE THE PURCHASERS SOLE AND EXCLUSIVE REMEDY UN- DER THIS WARRANTY. BEROAN-NUTONE SHALL NOT BE LIABLE FOR INGIDEN- TAL, GONSEQUENTIAL OR SPEGIAL DAMAGES ARISING OUT OF OR IN GON- NECTION WITH PRODUCT USE OR PERFORMANGE. Some states do not allow the exclusion or imitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal nights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To quality for warranty service, you must (a) notify Broan-NuTone at the address or phone number stated below, (b) give the model number and part identification and (с) describe the nature of any defect in the product or part. At the time of requesiing warranty service, you must present evidence of the onginal purchase date. In the U.S., contact: Broan-Nutone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) In Canada, contact: Broan-NuTone Canada, 1140 Tristar Drive Mississauga, Ontario LST 1H9 (1-B88-BB2-7625) 99042802F
advertisement
Related manuals
advertisement