Extron NAV E 511 Setup guide
Extron NAV E 511 is a streaming encoder that allows you to distribute and switch AV signals over a managed 1G IP network. With its HDMI and analog audio inputs, you can connect various sources like cameras, computers, or media players. The encoder supports HDCP-encrypted content and provides loop-through monitoring via the HDMI output. Control the encoder using the front panel buttons, embedded web pages, or Extron Toolbelt software. Utilize the USB 2.0 port for connecting a host or device. Additionally, the NAV E 511 offers extension and reset capabilities.
Advertisement
Advertisement
NAV E 511 • Setup Guide
IMPO
RTAN
T:
Go to www user guide
.extron.com f
, installation instructions, specifications bef
CLASS 1 LASER PRODUCT, see NAV E 511 User Guide at www.extron.com
.
WARNING:
The NAV E 511 output continuous invisible light (Class 1 rated), which may be harmful to the eyes; use with caution.
• Do not look into the fiber optic cable connectors or into the fiber optic cables themselves.
• Plug the attached dust caps into the optical transceivers when the fiber cable is unplugged.
AVERTISSEMENT :
Le NAV E 511 émettent une lumière invisible en continu (équipement de classe 1) qui peut être dangereuse pour les yeux ; à utiliser avec précaution.
• Ne pas fixer directement les connecteurs optiques ou les câbles fibre optique.
• Associez les bouchons anti-poussière à l’ensemble émetteur/récepteur optique lorsque le câble fibre optique est débranché.
This guide provides instructions for an experienced installer to install the Extron NAV E 511 streaming encoders and to make all connections. The Extron NAV encoder and one or more compatible decoders form an AV distribution and switching matrix on a managed
1G IP network.
NOTE : For more information on any subject in this guide, see the NAV E 511 User Guide , available at www.extron.com
.
Installation
Step 1 — Mounting
Turn off or disconnect all equipment power sources and rack or furniture mount the encoder as required.
Step 2 — Rear Panel Connections
POWER
12V
2.0 A MAX
INPUT
L
AUDIO
R
CONTROL
CONT RS-232 IR
USB 2.0
LAN
HDMI LOOP THRU C T Tx Rx G S G 5V/200 mA NAV 1G EXT
NAV E 511
RESET
Figure 1. NAV E 511 Rear Panel Features
A HDMI input port — Connect an HDMI cable between this port and the HDMI output port (or DVI port, with an appropriate adapter) of the digital video source.
B HDMI Loop Thru port — Connect a display to this female HDMI connector for local loop-through monitoring of the source signal.
NOTE:
See
on page 6 to securely fasten the HDMI connectors to the encoder for
A
and
B
.
C Audio input port — Connect balanced or unbalanced stereo audio input to this 5-pole, 3.5 mm captive screw connector (see
Analog audio input on page 6 to wire the connector).
D Control Contact Closure port — Connect an Extron Show Me ® cable to this port to allow the encoder to select itself as the input to the decoder, using the control system.
E Control RS-232/IR port — Connect a serial RS-232 signal, a modulated IR signal, or both to this 3.5 mm, 5-pole captive screw connector for bidirectional RS-232 and unidirectional IR communication with connected remote controlled devices using an Extron
control system (see Control connector
on page 6 to wire the connector).
F USB 2.0 port
— Connect a USB Type-C cable from a USB host or a USB device. See LockIt
fasten the USB connector to the encoder.
® Lacing Brackets on page 6 to securely
NOTE:
This connector is limited to supplying 200 mA in USB device mode.
1
IMPO
RTAN
T:
for the
Go to www.e
xtron.com
product specifications.
on page 1) — Use a pair of fiber cables to connect to a LAN on which one or more decoders also reside for streaming and control.
NOTE:
Ensure that you use the proper fiber cable for your encoder. Typically, singlemode fiber has a yellow jacket and multimode cable has an orange or aqua jacket.
port (see
on page 6 to wire the connector).
— This button initiates three modes of reset (see the NAV E 511 User Guide , available at www.extron.com
, for details).
wire the connector).
Step 3 — Front Panel Configuration Port Connection
CONFIG
HDMI
HDCP
INPUTS
HDMI AUDIO
ANALOG
AUDIO
NAV
STREAM
USB
USB
HOST
ACTIVE
LAN
NAV
-LNK-
EXT
-ACT-
ID
NAV E 511
F G
Figure 2. NAV E 511 Front Panel Features
A Configuration port — Connect a PC to the encoder via this front panel USB mini-B connector for configuration of the unit. The port uses IP over USB technology; the IP address is always 203.0.113.22 and CANNOT be changed. The Config port is also discoverable via Toolbelt (see the NAV E 511 User Guide ). The guide and Toolbelt are available for download at www.extron.com
).
Indicators
B Power LED — Indicates power and startup status.
• Blinking — The unit is receiving power and is booting up.
• Lit steadily — The unit is receiving power and is operational.
C Input LEDs
— Indicates status of the signal inputs.
• HDMI LED — The encoder is detecting an HDMI input.
• HDCP LED — The HDMI signal is HDCP encrypted.
• HDMI Audio LED — The embedded HDMI audio input is selected.
• Analog Audio LED — The analog audio input is selected.
D NAV LEDs — Indicate the output status of the A/V and USB streams, as follows:
• Stream
• Lit steadily – The encoder is actively streaming a NAV output consisting of video, audio, or both.
• Blinking – The encoder is actively streaming a NAV output, but network errors are present.
• Unlit - The encoder is not actively streaming a NAV output consisting of video, audio, or both.
• USB
• Lit steadily – The encoder is actively sending and receiving a NAV USB stream.
• Blinking – The encoder is unable to establish a NAV USB stream.
• Unlit — The encoder is not actively sending and receiving a NAV USB stream.
2
NAV E 511 • Setup Guide (Continued)
(see
figure 2 on page 2 — Indicates the status of the USB stream, as follows:
• Host
• Lit steadily – The encoder is in USB host mode, the default condition.
• Unlit – The encoder is in USB device mode.
• Active
• Lit steadily – A host or USB device is connected to the rear panel USB port.
• Unlit – No host or USB device is connected to the rear panel USB port.
• Blinking – A USB device or hub is connected to the encoder and is drawing more power than the USB port can supply.
— Indicates status of the network connection.
• NAV LED —
• Link LED — Lit steadily indicates that a network link is established at 1G.
• Act LED — Blinking indicates network traffic. The blink rate corresponds to activity.
• Ext LED —
• Link LED — Lit steadily indicates that a network link is established at 1G. Blinking indicates a link speed less than 1Gbps.
• Act LED — Blinking indicates network traffic. The blink rate corresponds to activity.
— The recessed ID button identifies the encoder to the NAVigator and decoder when pressed. The LED blinks when the encoder is in pairing mode (see
Pairing devices via front panel
on page 5 for details).
Operation
Power
When power is applied, the encoder runs a series of self-tests that blink the front panel Power LED and all other indicators. The encoder then boots the NAV operating system. It can take approximately 45 seconds for self-test and system startup to complete. When the process is complete, the Power LED lights steadily.
NOTE: The
encoder
is NOT operational until the boot process is complete (the Power LED is lit steadily)
.
System Operation
The encoder can be configured and controlled using embedded web pages or Extron Toolbelt (see the NAV E 511 User Guide available at www.extron.com
and the Toolbelt Help file).
NOTE:
The
“Connection via web pages,” Connection settings , and Pairing devices via front panel
procedures (see page 5) may
NOT be necessary if your system includes a NAVigator System Manager
.
3
Connection via web pages
Connection to the encoder and its embedded web pages can be made via either the front panel Configuration (USB) port (using IP over
USB technology) (see figure 2 , A
on page 2) or the rear panel NAV 1G port (see figure 1 , F on page 1).
Access the encoder using HTML pages as follows:
1. Start a web browser.
NOTES:
• Suggested browsers to fully support the NAV system are: Google Chrome ™ , Mozilla ™ Firefox ™ , and Microsoft
®
Edge ™ .
• The network must be properly configured for multicasting (IGMP). Failure to do so may result in degraded performance.
2. Enter the IP address of the encoder in the browser Address field.
NOTES:
• Default settings:
DHCP Port
Config (USB) *
NAV 1G (Fiber) On
IP address
203.0.113.22
Subnet mask
* For the Config port
, the address for IP over USB
CANNOT be changed.
If the unit does not receive a DHCP address , a self-assigned Link Local Address, is assigned in the range 169.254.
X
.
X
.
• If you use IP over USB, Extron recommends waiting a minute after plugging in the cable for your PC to identify the USB connection as a valid Ethernet port.
3.
4.
5.
Press the keyboard < Enter > key. The browser displays a privacy error message (see figure 3 at right for an example in the Chrome browser).
Click Advanced (see figure 3, 1 ). The button changes to Hide Advanced and explanatory text and a link appear below the button.
Click Proceed to < IP address > (unsafe) ( 2 ). The browser opens to the Login dialog box (see figure 4).
4
Figure 3. Privacy Error Message (in Chrome Browser)
6.
Figure 4. Login Dialog Box
Enter the Username (see figure 4, 1 ) and Password ( 2 ) and click Sign In ( 3 ). The browser opens to the embedded web pages
NOTES:
• The default Username is admin .
• The factory configured passwords for all accounts on this device have been set to the device serial number. If the password is reset, the encoder reverts to the default password, which is extron .
• Usernames and passwords are case sensitive.
NAV E 511 • Setup Guide (Continued)
Figure 5. HTML Page
NOTE: Detailed descriptions of communication, configuration, and monitoring are provided in the NAV E 511 User Guide , available at www.extron.com
.
Connection settings
View and change connection settings as follows:
1. On the home page, click Settings (see figure 5, 1 ) and then Network
Connection ( 2 ). The Network Connection pane opens (see figure 6), showing protected views of the network connection settings.
NOTE:
Editing of connection settings is disabled when the device is assigned to an Extron NAVigator System Manager.
2.
3.
4.
5.
To change the settings , click Edit (see figure 6, changes to Save .
1 ). The Edit button
Click in the desired field ( 2 ) and edit it as necessary.
Repeat step 3 as necessary for other values.
Click Save .
Pairing devices via front panel
Pair devices as follows:
1. Use a Tweeker or other small screwdriver to press and hold the encoder front panel ID button for approximately 3 seconds, until the ID LED blinks. The encoder enters pairing mode, which allows decoders to receive the AV and USB streams from encoders.
ID
2.
3.
One at a time, use a Tweeker or other small screwdriver to press and hold the decoder front panel ID button for approximately 3 seconds, until the
ID LED blinks three times. The decoder is now paired to the encoder.
Repeat step 2 for each decoder.
Figure 6. Network Connection Pane
5
4.
5.
Use a Tweeker or other small screwdriver to press and release the encoder front panel ID button. The encoder exits pairing mode.
Repeat steps 1 through 4 to pair decoders to other encoders.
After all devices are connected, powered on, and paired, the system is fully operational.
Operation in a System with a NAVigator
The Extron NAVigator is a system manager that easily configures and controls the NAV System. The NAVigator supports 16 endpoints by default, but a LinkLicense can upgrade its capabilities to support up to 240 endpoints.
See the NAVigator User Guide , available at www.extron.com
for details.
Connection Details
LockIt
®
Lacing Brackets
1. Plug the HDMI or USB cable into the panel connection (see 1 , at right for an HDMI example).
2.
3.
Loosen the connection mounting screw from the panel enough to allow the LockIt lacing bracket to be placed over it ( 2 ). The screw does not have to be removed.
Place the LockIt lacing bracket on the screw and against the connector (
3 to secure the bracket.
), then tighten the screw
ATTENTION:
• Do not overtighten the connector mounting screw. The shield it fastens to is very thin and can easily be stripped.
• Ne serrez pas trop la vis de montage du connecteur. Le blindage auquel elle est attachée est très fin et peut facilement être dénudé.
3
4.
5.
Loosely place the included tie wrap around the connector and the LockIt lacing bracket as shown (
4
).
While holding the connector securely against the lacing bracket, use pliers to tighten the tie wrap, then remove any excess length ( 5 ).
Analog audio input
Do not tin the wires!
Tip
Sleeve
Unbalanced Stereo Input
Tip
Ring
Sleeves
Tip
Ring
Balanced Stereo Input
EXT connector
Pins:
12345678
7
8
5
6
3
4
Pin
1
2
TIA/EIA T568B
Wire color
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
TP Wires
Control connector
IR Device
Rx Tx
Power connector
Smooth
Ridges
Captive
Screw
Connector
3"
16 (5 mm) MAX
A
Contact Tally out
Show Me Cable
Tx Rx Gnd
RS-232
Device
SECTION A–A
Power Supply
Output Cord
A
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.
6
©
2021 Extron — All rights reserved. www.extron.com
All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
68-3605-50 Rev. A
01 21
Download