Proware EP-4246J/JD-SCSC JBOD 4U 12G SAS - SAS/SATA User manual

Add to My manuals
44 Pages

advertisement

Proware EP-4246J/JD-SCSC JBOD 4U 12G SAS - SAS/SATA User manual | Manualzz

64 Bays

SAS to SAS/SATA

JBOD Subsystem

User Manual

Revision 1.1

64 Bays SAS to SAS/SATA JBOD Subsystem

Table of Contents

Preface ................................................................................................................................ 3

Before You Begin ............................................................................................................. 4

Safety Guidelines.................................................................................................................................................................... 4

Controller Configurations................................................................................................................................................... 4

Packaging, Shipment and Delivery ................................................................................................................................ 4

Unpacking the Shipping Carton ................................................................................................................................ 5

Chapter 1 Product Introduction ................................................................................. 6

1.1 Technical Specifications ........................................................................................................................................... 7

Chapter 2 Identifying Parts of the JBOD Subsystem ............................................ 8

2.1 Main Components ...................................................................................................................................................... 8

2.1.1 Front View ............................................................................................................................................................. 8

2.1.1.1 LCD Display Panel LED ........................................................................................................................... 9

2.1.1.2 HDD Status LEDs ................................................................................................................................... 10

2.1.1.3 Menu Diagram ........................................................................................................................................ 11

2.1.2 Rear View ............................................................................................................................................................ 12

2.3 Power Supply Fan Module (PSFM) .................................................................................................................. 13

2.3.1 PSFM Panel ........................................................................................................................................................ 15

2.4 Fan Module................................................................................................................................................................. 16

2.4.1 Turbo Fan ........................................................................................................................................................... 18

2.5 Disk Drive Installation into the Disk Slot ...................................................................................................... 19

2.5.1 To install a disk drive in a disk tray: ......................................................................................................... 20

Chapter 3 Getting Started with the Subsystem................................................... 23

3.1 Installing the Rails and Mounting into Rack .............................................................................................. 23

3.2 Removing the Disk Array from the Rack ...................................................................................................... 36

3.3 Preparing the JBOD and Connecting to RAID Subsystem ................................................................... 38

3.4 Preparing the JBOD and Connecting to SAS HBA in Host System ................................................. 38

3.5 Powering On .............................................................................................................................................................. 39

3.6 Powering Off .............................................................................................................................................................. 40

Chapter 4 Maintenance ............................................................................................. 41

4.1 Upgrading the JBOD Controller Firmware ................................................................................................... 41

2

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

Preface

About this manual

This manual provides information regarding the hardware features and installation of the

64Bay JBOD subsystem

. Information contained in the manual has been reviewed for accuracy, but not for product warranty because of the various environment/OS/settings. Information and specifications will be changed without further notice.

This manual uses section numbering for every topic being discussed for easy and convenient way of finding information in accordance with the user’s needs. The following icons are being used for some details and information to be considered in going through with this manual:

NOTES:

These are notes that contain useful information and tips that the user must give attention to in going through with the subsystem operation.

IMPORTANT!

These are the important information that the user must remember.

WARNING!

These are the warnings that the user must follow to avoid unnecessary errors and bodily injury during hardware and software operation of the subsystem.

CAUTION:

These are the cautions that user must be aware of to prevent damage to the subsystem and/or its components.

Copyright

No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent.

Trademarks

All products and trade names used in this document are trademarks or registered trademarks of their respective owners.

Changes

The material in this document is for information only and is subject to change without notice.

User Manual

3

64 Bays SAS to SAS/SATA JBOD Subsystem

Before You Begin

Before going through with this manual, you should read and focus on the following safety guidelines. Notes about the subsystem’s controller configuration and the product packaging and delivery are also included here.

Safety Guidelines

To provide reasonable protection against any harm on the part of the user and to obtain maximum performance, user is advised to be aware of the following safety guidelines particularly in handling hardware components:

Upon receiving of the product:

Place the product in its proper location.

Do not try to lift it by yourself alone. Two or more persons are needed to remove or lift the product to its packaging. To avoid unnecessary dropping out, make sure that somebody is around for immediate assistance.

It should be handled with care to avoid dropping that may cause damage to the product. Always use the correct lifting procedures.

Upon installing of the product:

Ambient temperature is very important for the installation site. It must not exceed 30

C. Due to seasonal climate changes; regulate the installation site temperature making it not to exceed the allowed ambient temperature.

Before plugging-in any power cords, cables and connectors, make sure that the power switches are turned off. Disconnect first any power connection if the power supply module is being removed from the enclosure.

Outlets must be accessible to the equipment.

All external connections should be made using shielded cables and as much as possible should not be performed by bare hand. Using anti-static hand gloves is recommended.

In installing each component, secure all the mounting screws and locks. Make sure that all screws are fully tightened. Follow correctly all the listed procedures in this manual for reliable performance.

Controller Configurations

This JBOD subsystem supports single JBOD controller configurations.

Packaging, Shipment and Delivery

Before removing the subsystem from the shipping carton, you should visually inspect the physical condition of the shipping carton.

Unpack and verify that the contents of the shipping carton are complete and in good condition.

Exterior damage to the shipping carton may indicate that the contents of the carton are damaged.

If any damage is found, do not remove the components; contact the dealer where you purchased the subsystem for further instructions.

4

User Manual

Unpacking the Shipping Carton

The shipping carton contains the following:

64 Bays SAS to SAS/SATA JBOD Subsystem

JBOD Subsystem Unit

64 pairs of HDD side brackets

Two (2) Power cords

Two (2) mini SAS HD cables

Two (2) serial cables DB9-to-DB9

Slide rail

Key of Top Cover

Screws

User Manual

NOTE: If any damage is found, contact the dealer or vendor for assistance.

User Manual

5

64 Bays SAS to SAS/SATA JBOD Subsystem

Chapter 1 Product Introduction

The 64 bays JBOD Subsystem

The JBOD subsystem is a 19-inch 4U rackmount JBOD unit. It is a versatile SAS3 /

SATA3 disk expansion system, ideal for high capacity and scalability storage in IT demands. It offers high density storage, hardware redundancy and easily integrates into versatile applications that request high performance and high scalability.

This JBOD subsystem comes with dual SAS Expander JBOD configuration. It features a modular architecture for key components which ease system maintenance and management.

Highest Density Available

- 4U chassis with 64 bays carriers

- Support the 3.5" enterprise class SAS3/SATA3 HDD drives

High Availability

- Dual SAS Expander JBOD consist of four 4x mini SAS HD ports

Power Supply

- Power supply and cooling system contained in 1 module for efficient cooling

- Two 1100W redundant hot swappable power supplies

Enclosure

- Incorporates SAS Expander on disk backplane for maximum signal integrity

- Utilizes industry-standard SCSI enclosure services (SES) to monitor enclosure and disk environmental conditions

Enclosure monitoring

- S.E.S. support for standard enclosure management

- System LED indications

- Fan speed monitoring

- Power supply monitoring

- System voltage monitoring

- System temperature monitoring

- System alarm

6

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

1.1 Technical Specifications

JBOD Redundant

Host Interface

Disk Interface

SAS expansion

Enclosure

Platform

Form Factor

Two 4x mini SAS HD (12Gb/s)

12Gb/s SAS, 6Gb/s SATA

Two 4x mini SAS HD (12Gb/s)

Rackmount

4U

# of Hot Swap Trays

Tray Lock

Disk Status Indicator

Disk Backplane

# of PS/Fan Modules

# of Fans

64

Yes

Access / Fail LED

SAS3 / SATA3

1100W x 2 w/PFC

15

Monitor port support

Power requirements

Environmental

Relative Humidity

Yes

AC 90V ~ 254V Full Range, 50Hz~60Hz

10% ~ 85% Non-condensing

Operating Temperature 10°C ~ 40°C (50°F ~ 104°F)

Physical Dimension 880(L) x 482.6(W) x 177(H) mm

Weight (Without Disk) 43.5 / 45 Kg

Specification is subject to change without notice.

User Manual

7

64 Bays SAS to SAS/SATA JBOD Subsystem

Chapter 2 Identifying Parts of the JBOD Subsystem

2.1 Main Components

2.1.1 Front View

8

User Manual

IMPORTANT: When powering off the JBOD subsystem, turn off first the Main Switch and allow at least 4 minutes for the subsystem to shutdown properly. Then turn off the switches of the 2 Power

Supply Fan Modules.

2.1.1.1 LCD Display Panel LED

64 Bays SAS to SAS/SATA JBOD Subsystem

Part

Power LED

Flashing Blue

Light Blue

No Light

Function

Green indicates power is ON.

Main Switch Button

Indicates that the power cords are inserted and/or indicates the 2 power supply switches are turn on.

Indicates that the sytem is on.

Indicates that the whole system is power off.

User Manual

9

64 Bays SAS to SAS/SATA JBOD Subsystem

2.1.1.2 HDD Status LEDs

The Front Panel shows the disk drives status.

Activity LED

Power On/Fail LED

Indicator Color Description

Activity LED

Blue

Blinking

Indicates the disk drive is busy or being accessed.

Green Indicates the disk drive in this slot is good.

Power

On/Fail LED

RED

LED is off

Indicates the disk drive in this slot is defective or failed.

Indicates there is no disk drive in this slot.

10

User Manual

2.1.1.3 Menu Diagram

Model-Name

F/W V x.x.xx

Temperature Chip1 30’C

Chip2 35’C

Voltage Status

Good

Chip3 31’C

Chip4 30’C

HDD01 33’C

:

HDD64 30’C

Power Status Power01 : Good

Good Power02 : Good

FAN Status

Good

Fan 1: 3970 rpm

Fan 2: 3970 rpm

Fan15: 3970 rpm

1. 5V_ 4.94V

1. 12V_ 12.19V

1. 1.8V_ 1.8V

1. 0.9V_ 0.94V

2. 5V_ 4.94V

2. 12V_ 12.48V

2. 1.8V_ 1.8V

2. 0.9V_ 0.94V

Alarm Status Disable / Enable Alarm

Enabled

64 Bays SAS to SAS/SATA JBOD Subsystem

User Manual

11

64 Bays SAS to SAS/SATA JBOD Subsystem

2.1.2 Rear View

NOTE: Each Power Supply Module has 1 Power Supply and 5 Fans.

The JBOD subsystem is logically divided into two enclosures for hardware monitoring.

The functions of the Expander are as follows:

Module: Function/Description:

Expander CLI A1 & A2

(RS-232 Port)

Expander CLI B1 & B2

(RS-232 Port)

SAS In Port

SAS Expansion Port

Link/Access LED

Use to upgrade the firmware of the expander module. Connect the serial cable DB9-to-DB9 to your system’s serial port. (for Expander 1)

Use to upgrade the firmware of the expander module. Connect the serial cable DB9-to-DB9 to your system’s serial port. (for Expander 2)

Use to connect to SAS HBA or to RAID subsystem’s SAS Expansion Port.

Use to connect to the SAS In Port of another JBOD subsystem.

Green indicates SAS IN/ Expansion

Port has connected or linked.

Green Blinking indicates SAS IN/

Expansion Port is being accessed.

12

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

2.3 Power Supply Fan Module (PSFM)

The 64bay RAID subsystem contains

two 1100W Power Supply/Fan Modules

.

All PSFM are inserted at the rear of the chassis.

Front Panel

Rear Side

NOTE: Each PSFM delivers Full-Range 100V ~ 240V (+/-10%) voltage AC electricity. Each PSFM consists of 1 power supply and 5 fans. Two Fans are located at the panel side, and three fans are located in rear side of the PSFM.

User Manual

13

64 Bays SAS to SAS/SATA JBOD Subsystem

Power Supply 1 Power Supply 2

Fan 1 Fan 2 Fan 7 Fan 8

Rear Side

Front Panel

NOTE: The first PSFM (Power Supply 1, on the left side of enclosure) has five fans: Fan 1 and Fan 2 on the front panel; and

Fan 3, Fan 4 and Fan 5 on the rear side.

The second PSFM (Power Supply 2, on the right side) has five fans also: Fan 7 and Fan 8 on the front panel; and Fan 9, Fan 10 and

Fan 11 on the rear side.

14

User Manual

Rear Side

Front Panel

2.3.1 PSFM Panel

64 Bays SAS to SAS/SATA JBOD Subsystem

Part

AC Power Input Socket

Description

Use to connect the power cord from power source.

Power On/Off Switch Use to power on or power off the PSFM.

Indicator Color

Green

Power Status

LED

Red

Fan Fail LED Red

Description

Indicates the power supply module is good.

Indicates the power supply module is faulty.

Indicates one or more fans in the PSFM has failed.

When the power cord connected from main power source is inserted to the AC

Power Input Socket the Power Status LED becomes RED . When the switch of the

PSFM is turned on, the LED still shows RED . After the main switch in front panel is turned on, the LED turns GREEN , which means it is functioning normally.

The PSFM has a

5V standby

DC voltage. When the power cord(s) is/are connected to the AC Power Input Socket, after 1 second, all Activity LEDs will flash once.

When the power cord(s) is/are disconnected from AC Power Input Socket, after 3 seconds, all Activity LEDs will flash twice.

User Manual

15

64 Bays SAS to SAS/SATA JBOD Subsystem

2.4 Fan Module

The 64bay JBOD subsystem contains 15 fans.

Power Supply 1 Power Supply 2

Fan 1 Fan 2 Fan 7 Fan 8

Rear Side

Front Panel

Rear Side

Front Panel

16

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

Indicator Color Description

No light Indicates the fan is normal.

Fan Fault LED

Red Indicates the turbo fail is faulty.

User Manual

17

64 Bays SAS to SAS/SATA JBOD Subsystem

2.4.1 Turbo Fan

The turbo fan (Fan 6) provides additional airflow inside the enclosure.

Turbo Fan LED

Status LED

Indicator

Status LED

Color

Red

Description

Indicates the turbo fail is faulty.

NOTE: The status of Turbo Fan (Fan 6) is monitored by Expander

Module 1.

18

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

2.5 Disk Drive Installation into the Disk Slot

This section describes the physical locations of the hard drives supported by the subsystem and give instructions on installing a hard drive.

NOTE: When the JBOD is shipped, the disk trays are not placed in the disk slots. If all disk trays will be used to install all 64 disk drives, for quicker and easier installation of disk drives in the

Disk Array, it is recommended to attach first each disk drive with

HDD side brackets.

Slot 61

Slot 1

Slot 64

DISK SLOT NUMBERS

Rear side

Slot 4

61 57 53 49 45 41 37 33 29 25 21 17 13 9 5 1

62 58 54 50 46 42 38 34 30 26 22 18 14 10 6 2

63 59 55 51 47 43 39 35 31 27 23 19 15 11 7 3

64 60 56 52 48 44 40 36 32 28 24 20 16 12 8 4

Front Side

User Manual

19

64 Bays SAS to SAS/SATA JBOD Subsystem

NOTE: In dual SAS Expander mode, it is strongly recommended to use SAS hard drive disks.

2.5.1 To install a disk drive in a disk tray:

1.

Prepare the HDD side brackets. Remove them from the dummy disk by pushing the upper sides of the dummy disk as shown below:

20

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

2.

Place the brackets on both sides of the disk drive and secure them with screws.

2 screws #6-32 UNC L=5.0mm

2 screws #6-32 UNC L=5.0mm

3.

Place the drive carefully in the disk slot.

User Manual

21

64 Bays SAS to SAS/SATA JBOD Subsystem

4.

Tighten the thumbscrews on the sides of the disk drive.

22

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

Chapter 3 Getting Started with the Subsystem

3.1 Installing the Rails and Mounting into Rack

NOTE: At least two persons are needed to lift the Disk Array. To reduce the weight of the Disk Array, remove the power supply modules from the rear of Disk Array. If disk drives are already installed in the disk trays, remove also the disk trays. Refer to appropriate sections on how to remove the power supply modules and how to remove the disk trays/disk drives.

NOTE: The sample model used in the following installation might not be the actual model for this manual.

NOTE: The Disk Array must be installed near the Disk Array or host system where it will be connected. A Phillips screwdriver is needed in installation.

WARNING! It is prohibited to put other enclosures on top of the

64-bay Disk Array because the total weight will not be supported by the rails.

Steps:

1.

Open the rail box.

2.

Remove the 2 rail assemblies and the screws/accessories from the box. Check its contents.

User Manual

23

64 Bays SAS to SAS/SATA JBOD Subsystem

3.

Insert three (3) M5 nuts on the 2 holes of the front left side of the rack post.

4U

Rack Post – Front Left Side

Position of M5 nuts on the 3 holes of left rack post

4.

Insert three (3) M5 nuts on the 2 holes of the front right side of the rack post.

4U

Rack Post – Front Right Side

Position of M5 nuts on the 3 holes of right rack post

24

User Manual

5.

Prepare the 2 rail assemblies.

64 Bays SAS to SAS/SATA JBOD Subsystem

Front Side of Rail Assembly Rear Side of Rail Assembly

6.

Hold one rail assembly and install in the front left side of rack. To install, align and insert the 2 latches of the rail into the 2 holes on the rack post. Use the

Lock Lever to lock the rail assembly in the left rack post.

Lower

M5 nut

Lock

Lever

View from Front Side of Front Left Rack Post

Lock Lever is Not Locked

User Manual

25

64 Bays SAS to SAS/SATA JBOD Subsystem

Lock

Lever

View from Front Side of Front Left Rack Post

Lock Lever is Locked

Lock

6 th

5 th

4 th

3 rd

2 nd

1 st

2 Latches

Lower

M5 Nut

View from Rear Side of Front Left Rack Post

2 Latches are inserted in the 4 th

and 6 th

holes from bottom (M5 nut)

26

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

7.

Install the other end of rail assembly to the left rear side. Align and insert the 2 latches on the 2 holes on the rear rack post, and then push the rail a little towards the rear side and lock the lock lever on the rack post.

Lock

Lever

Latches

View from Rear Side of Rear Left Rack Post

Lock

Lever

Latches

View from Rear Side of Rear Left Rack Post

Lock

Lever

View from Rear Side of Rear Left Rack Post

User Manual

27

64 Bays SAS to SAS/SATA JBOD Subsystem

8.

Repeat step 6 to install the other rail assembly into the right front side.

Lock

Lever

Lower

M5 nut

View from Front Side of Front Right Rack Post

Lock Lever is Not Locked

Lock

Lever

Lower

M5 nut

View from Front Side of Front Right Rack Post

Lock Lever is Locked

28

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

2 Latches

Lower

M5 nut

6 th

5 th

4 th

3 rd

2 nd

1 st

Lock

View from Rear Side of Front Right Rack Post

2 Latches are inserted in the 4 th

and 6 th

holes from bottom (M5 nut)

9.

Repeat step 7 to install the other end of rail assembly to the rack post of rear right side.

Lock

Lever

Latches

View from Rear Side of Rear Right Rack Post

User Manual

29

64 Bays SAS to SAS/SATA JBOD Subsystem

Latches

Lock

Lever

View from Rear Side of Rear Right Rack Post

30

User Manual

Latches

Lock

View from Rear Side of Rear Right Rack Post

64 Bays SAS to SAS/SATA JBOD Subsystem

10.

Pull the 2 middle rail members out from the rail assembly.

Front Left Side

Rear Left Side

Middle Rail Member of Rail Assembly on Left Side of Rack

Right Front Side

Front Side

View from Rear Side

Left Front Side

User Manual

31

64 Bays SAS to SAS/SATA JBOD Subsystem

11.

With at least 4 persons carrying the enclosure, insert the 2 inner rails (attached to the sides of the enclosure) into the middle rails. Slide the enclosure until it stops or about half way through.

NOTE: Be careful when inserting the 2 inner rails into the middle rails. The 2 inner rails must be parallel with the 2 middle rails so that 2 inner rails will insert and slide easily. Use hands to guide the inner rails when inserted into the middle rails.

Inner

Rail

Middle Rail

Inner Rail Aligned with and Inserted into the Middle Rail

Important: Make sure to hold the enclosure firmly in level position while inserting the enclosure in the rail. Keep holding the enclosure moved inside the rack. When the half rear side is inside the rack, you can put down the two rear handles but support in the bottom part of the enclosure is still needed so that the enclosure will not drop down.

32

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

View from Rear Side

12.

Press outwards the blue locks on both sides of the inner rail members at the same time. Then push the enclosure inwards (or backwards) until it goes inside the rack.

Blue Lock of

Inner Rail

View from Right Side of Enclosure

Blue Lock of Inner Rail is Pushed a Little Outwards and

Enclosure is Pushed Inwards

User Manual

33

64 Bays SAS to SAS/SATA JBOD Subsystem

View from Rear Side of Rack Cabinet

Enclosure is Pushed Inwards

13.

Insert the power supply modules.

34

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

14.

Use six (6) M5 screws to lock the enclosure into the rack post, one screw in each corner. Note that the screw driver will need to pass through the corner hole of front panel for the two upper corner holes on both sides.

Corner

Hole

Screw

Front Left Side Front Right Side

15.

Open the top cover and re-insert the disk drives / disk trays, if disk drives/disk trays were previously removed. Then close the top cover.

User Manual

35

64 Bays SAS to SAS/SATA JBOD Subsystem

3.2 Removing the Disk Array from the Rack

1.

Remove the six screws in the front corner.

Front Left Side Front Right Side

2.

Remove the power supplies in the rear and the disk drives from the disk slots.

36

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

3.

Carefully pull the subsystem.

4.

Push the white lock to release the subsystem from the rail.

User Manual

37

64 Bays SAS to SAS/SATA JBOD Subsystem

3.3 Preparing the JBOD and Connecting to RAID Subsystem

1.

Install the disk drives, if not yet installed. Refer to Section 2.5 Disk Drive

Installation for detailed information.

2.

Connect one end of SAS cable to the

SAS In Port

of the JBOD subsystem enclosure and the other end to the

SAS Expansion Port

of the RAID subsystem enclosure.

3.4 Preparing the JBOD and Connecting to SAS HBA in Host System

1.

Install the disk drives, if not yet installed. Refer to Section 2.5 Disk Drive

Installation for detailed information.

2.

Connect one end of SAS cable to the

SAS In Port

of the JBOD subsystem enclosure and the other end to the SAS HBA on the Host system.

38

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

3.5 Powering On

1.

Plug in all the power cords into the AC Power Input Socket located at the PSFM.

NOTE: The subsystem is equipped with redundant, full range power supplies with PFC (power factor correction). The system will automatically select voltage.

NOTE: The PSFM has a 5V standby DC voltage. When the power cord(s) is/are connected to the AC Power Input Socket, after 1 second, all Activity LEDs will flash once. When the power cord(s) is/are disconnected from AC Power Input Socket, after 3 seconds, all Activity LEDs will flash twice.

2.

Turn on each Power On/Off Switch of the PSFM. The main switch button in the front panel will still flashing blue.

NOTE: When the power cord connected from main power source is inserted to the AC Power Input Socket, the Power Status LED becomes RED . When the switch of the PSFM is turned on, the LED still shows RED . After the main switch in front panel is turned on, the LED turns GREEN , which means it is functioning normally.

Power Supply 1 Power Supply 2

User Manual

39

64 Bays SAS to SAS/SATA JBOD Subsystem

3.

Push the main switch button in the front panel to power on.

Main Switch

4.

Allow the machine a few moments to initialize before using it. The main switch button will continue flashing blue until the system is finished checking each disk slot.

NOTE: The system will initialize after turning on the Main Switch.

Each disk slot will be checked during subsystem initialization.

3.6 Powering Off

MPORTANT: When powering off the JBOD Subsystem, turn off first the Main Switch in the front panel and allow at least 4 minutes for the subsystem to shutdown properly. The main switch button in the front panel will flash blue.

When JBOD Subsystem has totally powered down, turn off the switches of the 2 Power Supply Fan Modules at the rear. The main switch button in the front panel will still flash blue until the power cords are pulled out from the sockets.

40

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

Chapter 4 Maintenance

4.1 Upgrading the JBOD Controller Firmware

NOTE: The JBOD firmware upgrade procedure must be done four times. First is the Expander A1, next is the Expander B1 and A2, then last the Expander B2.

NOTE: There must be no I/O in the disk drives in the JBOD subsystem (RAID volumes should not be accessed) during firmware upgrade.

Power Supply 1

Power Supply 2

1

2

3 4

Expander A1

Expander B1

Expander B2

Expander A2

Fan 6

NOTE: It is important to stop I/O access to JBOD subsystem during firmware upgrade.

User Manual

41

64 Bays SAS to SAS/SATA JBOD Subsystem

Steps:

1.

Please use the RS232 cable (DB9 to DB9) to connect Expander A1 RS232 Port and PC COM1 Port (or change to other COM Port as necessary).

2.

Open Windows HyperTerminal or other Program. Connect using COM1 (COM Port used in Step1), Baud Rate: 115200, n, 8, 1, Flow Control: None.

3.

Power on RAID subsystem.

4.

Please type Password :

00000000

, than press

Enter

in command line.

5.

Please type “system upgrade”, than press “Enter” in command line.

6.

Select Transfer & Send File.

You must finish within 25 seconds

42

User Manual

64 Bays SAS to SAS/SATA JBOD Subsystem

7.

Select your firmware file path, and select Xmodem in the communication protocol, and click transfer button.

8.

Wait for the transfer of file to complete.

User Manual

43

64 Bays SAS to SAS/SATA JBOD Subsystem

9.

When the transfer and firmware update is complete, please power cycle the JBOD.

10.

In command line, type “system info”, you can see the Expander firmware version.

44

User Manual

advertisement

Key Features

  • Supports 64 x 3.5" SAS3/SATA3 HDDs, maximizing storage capacity and density.
  • Dual SAS Expander JBOD configuration with four 4x mini SAS HD ports, ensuring reliable data transfer and redundancy.
  • Modular architecture for key components simplifies maintenance and management, reducing downtime and increasing efficiency.

Related manuals

Frequently Answers and Questions

How many bays does the Proware EP-4646JD-SCSC have?
It has 64 bays, supporting a large number of HDDs for high storage capacity.
What type of HDDs does it support?
It supports both SAS3 and SATA3 HDDs, providing flexibility in storage options.
Is it suitable for use in high-availability environments?
Yes, its dual SAS Expander JBOD configuration and hardware redundancy features ensure high availability and data protection.