Fedders Cased A-Coil AC1A Series Specifications

Add to My manuals
4 Pages

advertisement

Fedders Cased A-Coil AC1A Series Specifications | Manualzz

Residential & Light Commercial HVAC

AC1A Series Cased A-Coil

Upflow/Downflow, 1

1

2

thru 5 Tons

Rated in Accordance with ARI Standard 210/240.

Certification Applies Only When Used with

Proper Components as Listed with ARI.

Additional rating information can be found at www.aridirectory.org

Easy To Install:

All tubing exits through left hand side of front access panel

Split seam front access

Suction and discharge line extend past the outside of the cabinet

Fedders Cased Coils for use with the cool only condensing unit. This reliable matching cased coil was designed to compliment the Fedders full system.

The coils are available for use in R-22 systems. They are housed in a durable gauge painted cabinet and fully insulated for quiet, efficient operation.

Performance:

Rated in accordance with ARI Standard 210/240

A-Coils offer low pressure drops to enhance system performance and airflow characteristics

Quality Built:

Coils have sweat fitting refrigerant connections

Widths match flush with Fedders gas furnaces

Primary and secondary condensate drain connections are 3/4" F.P.T. – Flush Mounted

Condensate drain pan is constructed of high grade, heat resistant, corrosion free material

Copper tube aluminum fin coil

All evaporators are factory leak-tested, dehydrated, sealed and shipped with holding charge

Pressure taps on suction and liquid line

TXV is standard on all coils

R4.0 insulation value in case

All drain pans are compatible with UV lights

Limited 5-year warranty

Serviceability:

Front panel is removable for easy service and coil cleaning

Foil-Face insulation for easy cleaning

Product Specifications

COIL SPECIFICATIONS

MODEL

NUMBER

TYPE

AIR

FLOW*

FLUSH

FIT TO

FURNACE

WIDTH

CFM

RANGE

FACE

AREA

SQ. FT.

AC1A024A U, D

AC1A030A U, D

AC1A036A U, D

AC1A042A U, D

14.5, 16

14.5, 16, 17.5, 20.5

14.5, 16, 17.5, 20.5

17.5, 20.5

600 - 900

800 – 1,250

1,000 – 1,400

1,300 – 1,500

4.00

3.11

4.00

4.89

AC1A060A U, D 17.5, 20.5, 22 1,400 – 1,900 5.80

*U = Upflow Applications. D = Downflow Applications.

1 = Requires a 1/2" - 3/8" reducer.

2 = Requires a 1 1/8" - 3/8" reducer.

MODEL

NUMBER

600

AC1A024A 0.10

AC1A030A

AC1A036A

AC1A042A

AC1A060A

FINS

PER

INCH

14

14

14

12

12

TUBE

O.D.

3/8"

3/8"

3/8"

3/8"

3/8"

NUMBER

OF

ROWS

2

3

3

3

3

NUMBER

OF

CIRCUITS

4

6

6

6

6

LINE

CONNECTIONS O.D.

LIQUID SUCTION

3/8" 3/4"

3/8"

3/8"

3/8"

3/8" 1

700

0.11

STATIC PRESSURE DROP THROUGH WET COIL & HOUSING (INCHES WATER COLUMN / CFM)

800

0.12

900

0.13

0.15

1000 1100

0.17

0.19

0.19

0.20

1200

0.21

0.22

1300

0.23

1400

0.24

1500 1600 1700 1800

0.15

0.17

0.18

0.21

0.21

0.23

7/8"

7/8"

7/8"

7/8" 2

1900

0.23

Airflow configurations (drawings showing different installation configurations)

This product is ARI certified when matched with other Fedders products.

2

Specifications subject to change without notice.

Product Specifications

A

E

B F

C

3/4 NPT

DRAIN

D

3/4 NPT

DRAIN PLUGGED

MODEL

NUMBER

AC1A024A14

AC1A024A16

AC1A030A14

AC1A030A16

AC1A030A17

AC1A030A20

AC1A036A14

AC1A036A16

AC1A036A17

AC1A036A20

AC1A042A17

AC1A042A20

AC1A060A17

AC1A060A20

AC1A060A22

A

14.5

16

17.5

20.5

17.5

20.5

17.5

20.5

22

14.5

16

14.5

16

17.5

20.5

B

20.5

18.5

18.5

18.5

23.5

23.5

22.5

22.5

22.5

20.0

18.5

20.0

18.5

18.5

18.5

C

21

21

21

21

21

21

24

24

24

21

21

21

21

21

21

CASED COIL DIMENSIONS IN INCHES

D

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

3/4 NPT

E

13

14.5

16

19

16

19

16

19

20.5

13

14.5

13

14.5

16

19

F

SHIPPING

WEIGHT

(LBS)

51

52

52

53

55

58

65

67

69

42

43

44

45

46

51

20

20

20

20

20

20

23

23

23

20

20

20

20

20

20

SHIPPING DIMENSIONS

22.8

22.8

21.3

21.3

26.3

26.3

25.7

25.7

25.7

HEIGHT

22.8

21.3

22.8

21.3

21.3

21.3

24.2

24.2

24.2

24.2

24.2

24.2

27.2

27.2

27.2

LENGTH

24.2

24.2

24.2

24.2

24.2

24.2

16.4

17.9

19.4

22.4

19.4

22.4

19.4

22.4

23.9

WIDTH

16.4

17.9

16.4

17.9

19.4

22.4

3

Specifications subject to change without notice.

AC1A Series Cased A-Coil

COIL NOMENCLATURE

A C 1 A 036 A 14 * A

Brand Coil

A = Fedders Coil

Case Designation

C = Cased Coil

Position

1 = Upflow/Downflow

Design Series

A = A Series

Nominal Capacity

024 = 18,000/24,000 BTUH [5.28/7.03 kW]

030 = 30,000 BTUH [8.79 kW]

036 = 36,000 BTUH [10.55 kW]

042 = 42,000 BTUH [12.31 kW]

048 = 48,000 BTUH [14.07 kW]

060 = 60,000 BTUH [17.5 kW]

Casing Width

14 = 14.5" Casing Width

16 = 16" Casing Width

17 = 17.5" Casing Width

20 = 20.5" Casing Width

22 = 22" Casing Width

Major Revision

A = First Revision

Fedders Corporation

505 Martinsville Rd.

Liberty Corner, NJ 07938 USA

(908) 604-8686

Form No. F-Acoil-0407B

All product specifications reflect available information at the printing of this brochure.

Fedders reserves the right to revise or modify products and/or specifications without notice.

Copyright ©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc.

FD-016-0407B

4

Specifications subject to change without notice.

advertisement