Alcatel-Lucent Service Aggregation Router 7705 Installation Manual
โฆษณา
โฆษณา
Alcatel-Lucent 7705
SERVICE AGGREGATION ROUTER | RELEASE 1.0
S A R - 8 C H A S S I S I N S T A L L A T I O N G U I D E
Alcatel-Lucent Proprietary
This document contains proprietary information of Alcatel-Lucent and is not to be disclosed or used except in accordance with applicable agreements.
Copyright 2008 © Alcatel-Lucent. All rights reserved.
Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is subject to change without notice.
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.
Copyright 2008 Alcatel-Lucent.
All rights reserved.
Disclaimers
Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life-support machines, or weapons systems, in which the failure of products could lead directly to death, personal injury, or severe physical or environmental damage. The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications.
This document may contain information regarding the use and installation of non-Alcatel-Lucent products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent tries to ensure that this information accurately reflects information provided by the supplier, please refer to the materials provided with any non-Alcatel-Lucent product and contact the supplier for confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete information provided about non-Alcatel-Lucent products.
However, this does not constitute a representation or warranty. The warranties provided for
Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by
Alcatel-Lucent and its customers.
This document was originally written in English. If there is any conflict or inconsistency between the
English version and any other version of a document, the English version shall prevail.
When printed by Alcatel-Lucent, this document is printed on recycled paper.
Table of Contents
7705 SAR-8 Installation Guide Page 3
Table of Contents
Page 4 7705 SAR-8 Installation Guide
Table of Contents
7705 SAR-8 Installation Guide Page 5
Table of Contents
Page 6 7705 SAR-8 Installation Guide
List of Tables
7705 SAR-8 Installation Guide Page 7
List of Tables
Page 8 7705 SAR-8 Installation Guide
List of Figures
7705 SAR-8 Installation Guide Page 9
List of Figures
CSM Connectors and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Fan Module Connectors and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Page 10 7705 SAR-8 Installation Guide
List of Acronyms
Acronym
2G
3G
ABR
AC
ACL
AIS
Apipe
ARP
AS
ASAP
ATM
ATM PVC
B-bit
Batt A
BFD
BOF
BSTA
BTS
CBN
CBS
CC
CE
7705 SAR-8 Installation Guide
Expansion second generation wireless telephone technology third generation mobile telephone technology available bit rate alternating current attachment circuit access control list alarm indication signal
ATM VLL address resolution protocol autonomous system any service, any port asynchronous transfer mode
ATM permanent virtual circuit beginning bit (first packet of a fragment) battery A bidirectional forwarding detection boot options file
Broadband Service Termination Architecture base transceiver station common bonding networks committed buffer space control channel customer edge circuit emulation
Page 11
List of Acronyms
Acronym
CPE
Cpipe
CPU
CRC
CRON
CSM
CSPF
CV
CIR
CLI
CLP
CoS
CEM
CES
CESoPSN
CIDR
CW
DC
DC-C
DC-I
DDoS
DHCP
DNS
DoS dot1q
Page 12
Expansion circuit emulation circuit emulation services circuit emulation services over packet switched network classless inter-domain routing committed information rate command line interface cell loss priority class of service customer premises equipment circuit emulation (or TDM) VLL central processing unit cyclic redundancy check a time-based scheduling service (from chronos = time)
Control and Switching Module constrained shortest path first connection verification customer VLAN (tag) control word direct current
DC return - common
DC return - isolated distributed DoS dynamic host configuration protocol domain name server denial of service
IEEE 802.1q encapsulation for Ethernet interfaces
7705 SAR-8 Installation Guide
List of Acronyms
Acronym
FDB
FEC
FIB
FTN
Epipe
ESD
FC
FCS
DSCP
DTE
DU e911
E-bit
ECMP
EFM
ELER
GigE
GRE
GSM
HSDPA
HSPA
IBN
ICMP
ICP
IEEE
IETF
7705 SAR-8 Installation Guide
Expansion differentiated services code point data termination equipment downstream unsolicited enhanced 911 service ending bit (last packet of a fragment) equal cost multi-path
Ethernet in the first mile egress label edge router
Ethernet VLL electrostatic discharge forwarding class frame check sequence forwarding database forwarding equivalence class forwarding information base
FEC-to-NHLFE
Gigabit Ethernet generic router encapsulation
Global System for Mobile Communications (2G) high-speed downlink packet access high-speed packet access isolated bonding networks
Internet control message protocol
IMA control protocol cells
Institute of Electrical and Electronics Engineers
Internet Engineering Task Force
Page 13
List of Acronyms
Acronym
LLID
LSP
LSR
LTN
MAC
MBB
MBS
IP
LCP
LDP
LER
ILER
ILM
IMA
IOM
MD5
MDA
MEF
MFC
MIB
MIR
MLPPP
MP
MPLS
Page 14
Expansion ingress label edge router incoming label map inverse multiplexing over ATM input/output module
Internet Protocol link control protocol label distribution protocol label edge router loopback location ID label switched path label switch router
LSP ID to NHLFE media access control make-before-break maximum buffer space maximum burst size media buffer space message digest version 5 algorithm media dependent adapter
Metro Ethernet Forum multi-field classification management information base minimum information rate multilink point-to-point protocol multilink protocol multiprotocol label switching
7705 SAR-8 Installation Guide
List of Acronyms
Acronym
MRRU
MRU
MTSO
MTU
NHLFE
NNI
Node-B
PID
PIR
POP
PPP
PSN
PVCC
PW
PWE3
QoS
RDI
OAM
OAMPDU
OS
OSS
PDU
PE
PHY
7705 SAR-8 Installation Guide
Expansion maximum received reconstructed unit maximum receive unit mobile trunk switching office maximum transmission unit multi-tenant unit next hop label forwarding entry network-to-network interface similar to BTS but used in 3G networks (term used in
UMTS (3G systems while BTS is used in GSM (2G systems) operations, administration, and maintenance
OAM protocol data units operating system operations support system protocol data units provider edge router physical layer protocol ID peak information rate point of presence point-to-point protocol packet switched network permanent virtual channel connection pseudowire pseudowire emulation edge-to-edge quality of service remote defect indication
Page 15
List of Acronyms
Acronym
SAP
SAR
SAR-8
SDP
SIR
SLA
SNTP
SPF
RED
RSVP
RSVP-TE
R&TTE
RT
RTM
RTN
RTP
SSH
TCP
TDM
TLDP
TLV
TOS
TPID
TTM
UDP
UMTS
Page 16
Expansion random early discard resource reservation protocol resource reservation protocol - traffic engineering
Radio and Telecommunications Terminal Equipment receive/transmit route table manager battery return real-time protocol service access point service aggregation router service aggregation router - 8-slot chassis service destination point sustained information rate
Service Level Agreement simple network time protocol shortest path first secure shell transmission control protocol time division multiplexing targeted LDP type length value type of service tag protocol identifier tunnel table manager user datagram protocol
Universal Mobile Telecommunications System (3G)
7705 SAR-8 Installation Guide
Acronym
UNI
VC
VCCV
VCI
VLAN
VLL
VoIP
VP
VPC
VPI
VPN
WCDMA
WRED
List of Acronyms
Expansion user-to-network interface virtual circuit virtual circuit connectivity verification virtual circuit identifier virtual LAN virtual leased line voice over IP virtual path virtual path connection virtual path identifier virtual private network wideband code division multiple access (transmission protocol used in UMTS networks) weighted random early discard
7705 SAR-8 Installation Guide Page 17
List of Acronyms
Page 18 7705 SAR-8 Installation Guide
Preface
About This Guide
This guide provides site preparation recommendations, step-by-step procedures to install the
Alcatel-Lucent 7705 Service Aggregation Router (SAR) in a standard 19-inch utility rack, and instructions to install, provision, and remove the Control and Switching Module (CSM), adapter cards, and Fan module.
After the hardware installation process is completed, refer to the 7705 SAR OS documentation set for details on the boot process, software configuration, and Command
Line Interface (CLI) information to configure system and network parameters.
List of Technical Publications
The 7705 SAR-series OS documentation set is composed of the following guides:
• 7705 SAR OS Basic System Configuration Guide
This guide describes basic system configurations and operations.
• 7705 SAR OS System Management Guide
This guide describes system security and access configurations as well as event logging and accounting logs.
• 7705 SAR OS Interface Configuration Guide
This guide describes card and port provisioning.
• 7705 SAR OS Router Configuration Guide
This guide describes logical IP routing interfaces, IP-based filtering, and routing policies.
• 7705 SAR OS MPLS Guide
This guide describes how to configure Multiprotocol Label Switching (MPLS) and
Label Distribution Protocol (LDP).
• 7705 SAR OS Services Guide
This guide describes how to configure service parameters such as service access points (SAPs), service destination points (SDPs), customer information, user services, and Operations, Administration and Management (OAM) tools.
7705 SAR-8 Installation Guide Page 19
Preface
• 7705 SAR OS Quality of Service Guide
This guide describes how to configure Quality of Service (QoS) policy management.
Warnings and Notes
Observe the warnings and notes in this guide to avoid injury or router damage during installation and maintenance. Follow the safety procedures and guidelines when working with and near electrical equipment. Warning statements and notes are provided in each chapter.
Audience
This guide is intended for network installers and system administrators who are responsible for installing, configuring, or maintaining networks. This guide assumes you are familiar with electronic and networking technologies.
Information Symbols
describes symbols contained in this guide.
Symbol Meaning
Danger
Warning
Table 1: Information Symbols
Description
This symbol warns that improper handling and installation could result in bodily injury. An electric shock hazard could exist. Before you begin work on this equipment, be aware of hazards involving electrical circuitry, be familiar with networking environments, and instigate accident prevention procedures.
This symbol warns that improper handling and installation could result in equipment damage or loss of data.
Caution This symbol warns that improper handling may reduce your component or system performance.
Page 20 7705 SAR-8 Installation Guide
Preface
Symbol Meaning
Note
Class 1 Laser Product
Table 1: Information Symbols (Continued)
Description
This symbol provides additional operational information.
Class 1 laser products are identified in the adapter card installation guides. Only approved Class 1 replaceable laser transceivers should be used with this product.
Technical Support
If you purchased a service agreement for your 7705 SAR-8 and related products from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller for assistance. If you purchased an Alcatel-Lucent service agreement, contact technical assistance at:
Web: http://www1.alcatel-lucent.com/comps/pages/carrier_support.jhtml
7705 SAR-8 Installation Guide Page 21
Preface
Page 22 7705 SAR-8 Installation Guide
Mandatory Regulations
In This Chapter
The following sections describe the mandatory regulations that govern the installation and operation of the 7705 SAR-8:
•
•
General Requirements on page 25
•
•
United States Regulations on page 29
•
European Union Regulations on page 31
•
Australia/New Zealand Regulations on page 35
•
7705 SAR-8 Installation Guide Page 23
Mandatory Regulations
List of Terms
lists the terms used in this chapter.
EEC
EMC
EMI
EN
FCC
ICES
IEC
IEE
Term
ACMA
ACTA
ANSI
AS/NZ
CE
CFR
CSA International
ETSI
LVD
NRTL
OSHA (USA)
RoHS
SELV
UL
WEEE
Table 2: List of Terms
Expansion
Australian Communications and Media Authority
Administrative Council for Terminal Attachments
American National Standards Institute
Australian/New Zealand standard
Conformité Européene
Code of Federal Regulations
Canadian Standards Association International
European Economic Community
Electromagnetic Compatibility
Electromagnetic Interference
European Standards
Federal Communications Commission
Interference Causing Equipment Standard
International Electrotechnical Commission
Institute of Electrical Engineers (UK)
European Telecommunications Standards Institute
Low Voltage Directive
Nationally Recognized Testing Laboratory
Occupational Safety and Health Administration (USA)
Restriction of the use of certain Hazardous Substances
Safety Extra Low Voltage
Underwriters Laboratories
Waste Electrical and Electronic Equipment
Page 24 7705 SAR-8 Installation Guide
Mandatory Regulations
General Requirements
The sections that follow outline the mandatory regulations that govern the installation and operation of the
7705 SAR-8
. You must adhere to these instructions so that your system meets regulatory requirements.
Danger: When removing cards from a shelf under power, some of the components such as the DC converters may be extremely hot. Handle by the card guides only.
Warning: There are no user-serviceable parts in this unit. Refer servicing to qualified personnel.
Warning: To prevent accidental electrical short circuits, align the card correctly between the card guides before inserting it in the slot.
Warning: The unit should be connected to a DC branch circuit with a maximum 10A circuit breaker or fuse that meets the requirements for branch circuit protection. A suitable disconnect device, such as a circuit breaker or switch, must be provided in the DC branch circuit and must be used to disconnect power to the system during servicing.
Equipment Interconnection Points
Interconnection points of the
7705 SAR-8
are defined as the following SELV connectors:
• T1/E1
• Ethernet (10/100/1000 Base-T)
• alarms
• clock inputs and clock outputs (BITS, 2 MHz, 5 MHz, 10 MHz)
SELV
Connect SELV circuits on this equipment only to other circuits that comply with the requirements of SELV circuits as defined in CSA C22.2 No. 60950-1, UL 60950-1,
EN 60950-1, AS/NZS 60950-1, and IEC60950-1.
Prevention of Access
The 7705 SAR-8 must be accessible only to authorized personnel. Install this apparatus in a restricted access location or similar environment to prevent unauthorized access.
7705 SAR-8 Installation Guide Page 25
Mandatory Regulations
Laser Interface
The
7705 SAR-8
uses a fiber-optic communications method and is an FDA and IEC Class 1
Laser product. Only trained service personnel thoroughly familiar with laser radiation hazards should install or remove the fiber-optic cables and cards in this system.
Protective Safety Ground (Earth)
The cable used for safety ground should be at least the same gauge as the supply conductors, green and yellow in color, and of sufficient length to connect the building earth point to the chassis ground connection (refer to the installation chapter for specific instructions on connecting the chassis ground).
EMC Compliance
EMC compliance may require the use of ferrites, shielded cables or other special accessories. Where required, these special accessories must be installed as per the instructions.
To maintain EMC compliance, cables that are shielded and grounded at both ends must be used on the following cards, interfaces, and ports:
• CSM card
→ Management (Ethernet), DB9 Console, and Synchronization interfaces
• 8-port Ethernet Adapter card
→ Fast Ethernet interface (CAT5 shielded cable)
→ Gigabit Ethernet interface (CAT5E shielded cable)
• 16-port T1/E1 ASAP Adapter card
→ T1 and E1 interfaces
• Fan module
→ DB15 Alarm port
Page 26 7705 SAR-8 Installation Guide
Mandatory Regulations
Regulatory Symbols
The
7705 SAR-8
uses various regulatory approvals symbols. They may be used on product markings such as approvals labels. These symbols are described in IEC 417.
show symbols of a terminal that you must connect to earth ground before you make any other connections to the equipment.
Figure 1: Protective Earth (ground)
9717
Figure 2: Earth (ground)
9718
7705 SAR-8 Installation Guide Page 27
Mandatory Regulations
Canada Regulations
This section describes the mandatory regulations that govern the installation and operation of the
7705 SAR-8
in Canada.
Industry Canada Regulations
ICES-003: Interference-Causing Equipment Standard Digital Apparatus
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
IC CS-03: Specification for Terminal Equipment, Terminal Systems,
Network Protection Devices, Connection Arrangements and Hearing Aids
Compatibility
This product meets the applicable Industry Canada technical specifications with respect to
IC CS-03: Specification for Terminal Equipment, Terminal Systems, Network Protection
Devices, Connection Arrangements and Hearing Aids Compatibility
Registration number: IC: 1737F-0010.
EMC Compliance
EMC compliance may require the use of ferrites, shielded cables or other special accessories. Where required, these special accessories must be installed as per the instructions.
Safety Approval for DC Systems
The DC source for the system must meet the requirements of a SELV source to comply with
CSA standard C22.2 No. 60950-1. Use the system with a SELV secondary source that is electrically isolated from the AC source and that is grounded reliably.
The 7705 SAR-8 is safety certified according to CSA standard C22.2 No. 60950-1 by CSA.
Page 28 7705 SAR-8 Installation Guide
Mandatory Regulations
United States Regulations
This section describes the mandatory regulations that govern the installation and operation of the
7705 SAR-8
in the United States.
Federal Communications Commission
FCC Part 15
Important! Changes or modifications not expressly approved by Alcatel-Lucent could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s expense.
FCC Part 68
The T1 network interface on this equipment meets the FCC specifications.
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the
ACTA. On the equipment is a label that contains, among other information, a product identifier in the format of AAAEQ##TXXXX.
Identification Number: GQ6DENAN7705SAR
In the event that repairs to this equipment are needed, contact:
Technical Support Services
Alcatel-Lucent
Within the United States: 1-866-582-3688, prompt 1
7705 SAR-8 Installation Guide Page 29
Mandatory Regulations
NRTL
This equipment is certified by the NRTL as meeting the requirements of UL 60950-1, Safety of Information Technology Equipment.
NRTL Approval for External DC Supplies
When the system is equipped with an AC rectifier, the rectifier must have NRTL-accredited approval. In addition, the DC outputs must meet UL 60950-1 SELV requirements.
Safety Approval for DC Systems
The DC source for the system must meet the requirements of a SELV source in accordance with UL 60950-1. You must use the system with a SELV secondary source that is electrically isolated from the AC source and that is grounded reliably.
Food and Drug Administration
This product complies with 21 CFR 1040.10 and 1040.11 regulations, which govern the safe use of lasers. Only qualified service personnel, thoroughly familiar with laser radiation hazards, should install or remove the fiber-optic cables used in this system. You can find information about the safe use of lasers in ANSI Z 136.1: Safe Use of Lasers and ANSI Z
136.2: Safe Use of Lasers in Optical Fiber Communications Systems. You can obtain these documents and other instructional material from:
Laser Institute of America
12424 Research Parkway, Suite 125
Orlando, FL 32826-3274
Page 30 7705 SAR-8 Installation Guide
Mandatory Regulations
European Union Regulations
Declaration of Conformity
Hereby, Alcatel-Lucent declares that the equipment documented in this publication is in compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC and
2004/108/EC
.
The technical documentation as required by the Conformity Assessment procedure is kept at the Alcatel-Lucent location that is responsible for this product. For more information please contact your local Alcatel-Lucent Customer Service Organization.
EU Compliance Statement
This product has been CE marked in accordance with the requirements of European
Directive 99/05/EC, the Radio and Telecommunications Terminal Equipment Directive
(R&TTE),
and 2004/108/EC, the Electromagnetic Compatibility (EMC) Directive
.
EMC/EMI Compliance
The equipment complies with the following EMC and EMI specification: EN 300 386
Class A.
General
This equipment must be permanently grounded.
Laser Interface
The system uses laser devices that are rated in accordance with IEC 60825-1 as Class 1 devices.
7705 SAR-8 Installation Guide Page 31
Mandatory Regulations
Safety Approval for DC Systems
The DC source for the system must meet the requirements of a SELV source as defined in
EN 60950-1. For 60V station battery systems, the source is considered TNV-2 as per
IEC/EN 60950-1 and must have reinforced insulation from the AC mains.
The equipment complies with the following Product Safety specification: EN 60950-1.
Protective Earth
Protective earth is referred to as chassis ground in this document. A green and yellow colored earth wire must be connected from the site equivalent of the AC earth to all shelves in accordance with IEE Wiring Regulations (16th edition). This connection is made via the chassis ground connection (refer to the installation chapter for specific instructions on connecting the protective earth). The protective earth is also carried by the mains plug and socket (for AC systems only).
Approval for External AC Rectifiers
When the system is equipped with an external AC rectifier, the rectifier must meet
EN 60950-1 SELV DC output requirements. Make sure that the rectifier is rated and adjusted for the appropriate AC input voltage and frequency for the country where it is installed. Set the output of the rectifier according to the installation and operating instructions of the manufacturer, to provide output levels that coincide with the nominal DC input ratings of the system.
Eco-Environmental
Packaging collection and recovery requirements
Countries, states, localities, or other jurisdictions may require that systems be established for the return and/or collection of packaging waste from the consumer, or other end user, or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for the return and/or collection of the packaging waste may be established.
For more information regarding collection and recovery of packaging and packaging waste within specific jurisdictions, please contact the Environmental Health and Safety organization.
Page 32 7705 SAR-8 Installation Guide
Mandatory Regulations
For installations not performed by Alcatel-Lucent, please contact the Alcatel-Lucent
Customer Support Center at:
Technical Support Services
+1 630 224 4672, prompt 2
Recycling / take-back / disposal of product
Electronic products bearing or referencing the symbol shown in
, when put on the market within the European Union, shall be collected and treated at the end of their useful life in compliance with applicable European Union and local legislation. They shall not be disposed of as part of unsorted municipal waste. Due to materials that may be contained in the product, such as heavy metals or batteries, the environment and human health may be negatively impacted as a result of inappropriate disposal.
Note: In the European Union, the WEEE symbol (a wheeled trash bin that has been crossed out and is positioned above a solid bar) indicates that the product was put on the market after 13 August 2005. This product is compliant with the WEEE marking requirements of
DIRECTIVE 2002/96/EC Waste Electrical and Electronic Equipment (WEEE).
Figure 3: WEEE Symbol for post-August 13, 2005 Product
Moreover, in compliance with legal requirements and contractual agreements, where applicable, Alcatel-Lucent will offer to provide for the collection and treatment of Alcatel-
Lucent products bearing the logo at the end of their useful life, or products displaced by
Alcatel-Lucent equipment offers. For information regarding take-back of equipment by
Alcatel-Lucent, or for more information regarding the requirements for recycling/disposal of product, please contact your Alcatel-Lucent Account Manager or Alcatel-Lucent Takeback
Support at [email protected].
7705 SAR-8 Installation Guide Page 33
Mandatory Regulations
Material Content Compliance
European Union (EU) Directive 2002/95/EC, “Restriction of the use of certain Hazardous
Substances” (RoHS), restricts the use of lead, mercury, cadmium, hexavalent chromium, and certain flame retardants in electrical and electronic equipment. This Directive applies to electrical and electronic products placed on the EU market after 1 July 2006, with various exemptions, including an exemption for lead solder in network infrastructure equipment.
Alcatel-Lucent products shipped to the EU after 1 July 2006 comply with the EU RoHS
Directive.
Page 34 7705 SAR-8 Installation Guide
Mandatory Regulations
Australia/New Zealand Regulations
This section describes the mandatory regulations that govern the installation and operation of the 7705 SAR-8 in Australia and New Zealand.
ACMA Regulations
The 7705 SAR-8 complies with the ACMA requirements and the product is marked with the
'A Tick' under the Supplier Code N594.
EMC
This Class A digital apparatus complies with AS/NZS CISPR22.
Telecom
This product meets the applicable ACMA technical specifications: AS/ACIF S016.
Safety
All products supplied in Australia are to be safe and to comply with an applicable Australian
Standard electrical safety standard.
The 7705 SAR-8 complies with the AS/NZS 60950 — Business Equipment, Computers,
Telecommunications requirements.
7705 SAR-8 Installation Guide Page 35
Mandatory Regulations
China Regulations
The statements that follow are the product conformance statements that apply to the
7705 SAR-8 when deployed in China.
Safety
The equipment complies with the Product Safety specification of IEC 60950-1.Eco-
Environmental.
Packaging Collection and Recovery Requirements
Countries, states, localities, or other jurisdictions may require that systems be established for the return and/or collection of packaging waste from the consumer, or other end user, or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for the return and/or collection of the packaging waste may be established.
For more information regarding collection and recovery of packaging and packaging waste within specific jurisdictions, please contact the Alcatel-Lucent Environmental Health and
Safety organization. For installations not performed by Alcatel-Lucent, please contact the
Alcatel-Lucent Customer Support Center at:
Technical Support Services
+1 630 224 4672, prompt 2
Material Content Compliance
The People’s Republic of China Ministry of Information Industry has published a regulation
(Order #39) and associated standards regarding restrictions on hazardous substances (China
RoHS). Currently, the legislation requires all Electronic and Information Products (EIP) to comply with certain labeling and documentation requirements. Alcatel-Lucent products manufactured on or after 1 March 2007, that are intended for sale to customers in the China market, comply with these requirements.
Page 36 7705 SAR-8 Installation Guide
Mandatory Regulations
In accordance with the People’s Republic of China Electronic Industry Standard “Marking for the Control of Pollution Caused by Electronic Information Product” (SJ/T11364-2006), customers may access Alcatel-Lucent’s Hazardous Substances Table information at either of the following two URLs:
• Access via the Alcatel-Lucent Corporate website at: http://www.alcatel-lucent.com/cn
• Access via the Alcatel Shanghai Bell website at: http://www.alcatel-sbell.com.cn/product_solution/in4.asp
7705 SAR-8 Installation Guide Page 37
Mandatory Regulations
Page 38 7705 SAR-8 Installation Guide
7705 SAR-8 Overview
In This Chapter
This chapter provides an introduction to the Alcatel-Lucent 7705 SAR-8:
•
7705 SAR-8 Components on page 40
→
→
→
→
→
→
→
Distribution Panels on page 46
•
SAR System Installation Process on page 49
7705 SAR-8 Installation Guide Page 39
7705 SAR-8 Components
7705 SAR-8 Components
The main components of the 7705 Service Aggregation Router (SAR) are the chassis,
Control and Switching Module (CSM), adapter cards, and Fan module. In addition, there are optional distribution panels to connect the adapter cards to the customer equipment.
Figure 4 shows the front view of the 7705 SAR-8. There are eight horizontal slots for the
CSMs and adapter cards, and one vertical slot for the Fan module. The connectors for the
DC power feeds are located to the right of the Fan module and are factory-installed. The
CSM, adapter cards, and Fan module are installed by the customer. All physical connections are made from the front of the unit, including the chassis ground point. There are no back panel connections.
Figure 4: 7705 SAR-8 Front View
SLOT ID
CSM A
MDA 1
MDA 3
CSM B
MDA 2
MDA 5
MDA 4
MDA 6
CSM
Stat
Act
Pwr
Mgmnt Port
A16-CHDS1
Stat Act
Pwr Port
Console
Ports 1-16
Sync
In Out
A8-ETN
Stat
Pwr
Link 1 Act
Link 2 Act
Link 3 Act
Link 4 Act
Link 5 Act
Link 6 Act
Link
Act Link
Act
7
CSM
Stat Act
Pwr
Mgmnt Port
A16-CHDS1
Stat
Act
Pwr Port
A16-CHDS1
Stat Act
A8-ETN
Pwr
Port
Stat
Console
Ports 1-16
Ports 1-16
Pwr
Link 1 Act
Link 2 Act
Link 3 Act
Link 4 Act
Link 5 Act
Link 6 Act
Link
Act
Link Act
7
Sync
In
Out
8
Fan
Batt A
Batt B
7705 SAR-8
Alarm
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
19634
Chassis
The chassis is shipped with a backplane, card cage, and connectors for the DC power feeds.
Mounting brackets for the 7705 SAR-8 chassis are factory-installed so the unit can be mounted in a recommended 19-inch wide rack. The chassis grounding stud is on the righthand side bracket. Slot covers are also factory-installed.
Figure 5 identifies the slots used for the CSMs, adapter cards (MDA), and Fan module. In
redundant systems, the CSMs go in slots CSM A and CSM B, and the adapter cards are installed in slots MDA 1 through MDA 6. In simplex systems, the CSM goes in slot CSM A, a slot cover goes on slot CSM B, and the adapter cards go in slots MDA 1 through MDA 6.
Page 40 7705 SAR-8 Installation Guide
7705 SAR-8 Overview
.
Figure 5: 7705 SAR-8 Slot Identification
CSM A
MDA 1
MDA 3
MDA 5
CSM B
MDA 2
MDA 4
MDA 6
Batt A
FAN
Batt B
19635
CSM
The Control and Switching Module (CSM) has three main functions:
• it provides the management and console interfaces to the 7705 SAR-8
• it provides system synchronization interfaces for external synchronization input and output signals
• it controls the routing, switching, and services functions for the entire system
Each CSM is shipped with one compact flash memory device that stores system boot images, software images, and configuration files and logs. The compact flash device cannot be accessed or removed by an operator or installer.
Figure 6 shows the CSM faceplate. Refer to
CSM Connectors and LEDs on page 112
for identification and description of the CSM faceplate features.
Figure 6: 7705 SAR-8 CSM Features
CSM
Stat Act
Pwr
Mgmt Port Console
Sync
In Out
19636
There must be at least one CSM installed in the 7705 SAR-8. Install two CSMs for system redundancy. The redundant CSM operates in standby mode and takes over system operation if the active (primary) CSM fails. CSMs are field-replaceable and hot-swappable. Refer to
7705 SAR OS Basic System Configuration Guide for information on CSM redundancy.
7705 SAR-8 Installation Guide Page 41
7705 SAR-8 Components
The CSM connects directly to the backplane and carries traffic between adapter cards. The switch fabric portion of the CSM receives and directs traffic to the appropriate destinations according to the routing information.
The CSM also provides 1.0/2.3 coaxial connectors for an external synchronization input and output. For redundant CSM configurations, a Y-cable can be used to connect the Sync In connectors on the two CSMs to the same external synchronization source.
Note: There is an IOM software module on the CSM that must be activated before any adapter card and port parameter can be provisioned and configured. The IOM is activated using the card
and card-type
CLI commands to specify its slot number and card type.
See Provisioning CSM and Adapter Card Parameters on page 108 for more information.
Adapter Cards
Figure 7 shows a sample adapter card. Adapter cards on the 7705 SAR-8 provide a wide
variety of interfaces of different speed and type, including Ethernet (10/100/1000 Base-T and optical), T1/E1 with ATM and IMA, and TDM (channelized and unchannelized).
The following adapter cards are supported in the 7705 SAR-8:
• 16-port T1/E1 ASAP Adapter card
• 8-port Ethernet Adapter card
The 16-port T1/E1 ASAP Adapter cards can support T1/E1 connections via a distribution panel. The 8-port Ethernet Adapter adapter cards can support six 10/100 Base-T ports and 2
SFP ports.
Adapter cards are hot-swappable and field-replaceable by qualified personnel. Adapter cards
install in slots MDA 1 through MDA 6. Refer to Figure 5 for adapter card slot locations on
the 7705 SAR-8, and to the appropriate adapter card installation guide for installation and
LED information.
Page 42 7705 SAR-8 Installation Guide
7705 SAR-8 Overview
Figure 7: 7705 SAR-8 Adapter Card
A16-CHDS1
Stat
Act
Pwr
Port
Ports 1-16
19637
Slot Covers
Figure 8 shows a slot cover. Slot covers (blank panels) are required on all empty slots to
prevent dust accumulation, help control airflow and confine electromagnetic interference, and for safety reasons. Slot covers do not have board components or connector pins.
shows a cover on slot MDA 3.
Figure 8: 7705 SAR-8 Slot Cover
19638
Power System
The 7705 SAR-8 has two power connectors mounted on the front of the chassis. These connectors provide access for two independent -48/-60 VDC power feeds, providing power redundancy for the system. When only one power feed is used, the system does not have power supply redundancy. The 7705 SAR-8 has a distributed power design, where each
CSM and adapter card provides independent power for its own functionality. The power system has no field-replaceable parts.
The DC power LEDs are located on the Fan module (see
). Refer to
Connectors and LEDs on page 114 for a description of the Fan module LEDs.
7705 SAR-8 Installation Guide Page 43
7705 SAR-8 Components
Refer to DC Power Connections on page 77
for requirements and information regarding preparing DC power cables.
Note: For sites that operate using +24VDC supplies, a +24VDC to -48VDC converter is needed to provide power to the 7705 SAR-8.
Figure 9: Fan Module
7705 SAR-8
FAN
Batt A
Batt B
Alarms
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
19639
Fan Module
Figure 9 shows the Fan module. The Fan module provides cooling for the system, as well as
alarm indicators (LEDs), an external alarm I/O connector, and an Audible Alarm
Cutoff/Lamp Test (ACO/LT) pushbutton.
The Fan module is hot-swappable and field-replaceable by qualified personnel. It must always be installed and fully operational while the 7705 SAR-8 is powered up. During routine maintenance and Fan module replacement, the system can operate safely for up to four minutes.
Fan Operation
The Fan module houses eight fans. Air enters from the intake vent on the right side of the chassis and exits through the exhaust vent on the left side. The fans have one operating speed
(full speed) and are always operational, regardless of ambient temperature.
Page 44 7705 SAR-8 Installation Guide
7705 SAR-8 Overview
Individual fans are not field-replaceable; however, there is sufficient cooling even if one of the fans fails. A critical alarm is generated when one or more fans fails. If one fan has failed the module should be replaced as soon as possible. If more than one fan has failed, the Fan module must be replaced immediately.
The FAN LED on the Fan module provides the following indications:
• green: normal operation
• amber: one or more fans out of operation
• unlit: fan power failure
Monitoring Temperature
Each CSM and adapter card has temperature sensors to continuously monitor its own temperature and report the temperature to the CSM. If the temperature of any card exceeds the preset threshold of 75ºC (167ºF), then an alarm is generated. The show chassis
CLI command displays the problem; check the Over Temperature state value, which will show
“Out of range”.
If the temperature inside the chassis becomes high enough to damage a card or the system, safety mechanisms are activated until a safe operating level is reached. Normal operating conditions do not activate any safety mechanisms. Safety mechanisms include shutting down a card until its temperature returns to an operationally safe value, at which time the card resets and returns to service.
If the FAN LED is amber (indicating a fan problem), a Fan Fail Alarm or a Temperature
Threshold Alarm is raised and the Fan module should be replaced.
7705 SAR-8 Installation Guide Page 45
7705 SAR-8 Components
Distribution Panels
Distribution panels are used with 16-port T1/E1 ASAP Adapter cards to connect to T1/E1 circuits.
There are two distribution panels:
• BNC
• RJ45
Note: The connector on the faceplate of the 16-port T1/E1 ASAP Adapter card is a 68-pin
AMP connector that provides a SCSI-2 interface. Although the connector is sometimes referred to as a SCSI-2 connector, this document refers to it as a 68-pin AMP connector. This naming convention applies to the connector on any T1/E1 cable that attaches to the 16-port
T1/E1 ASAP Adapter card.
BNC Distribution Panel
Figure 10 shows the BNC Distribution panel. Table 3
lists the panel features.
The BNC panel provides 75-ohm E1 access for up to 32 ports. On the customer side, each access port has separate transmit and receive BNC female connectors. On the equipment side, the panel has two sets of 68-pin AMP connectors for connection to two 16-port T1/E1
ASAP cards via 68-pin AMP to 68-pin AMP T1/E1 cables (see T1/E1 Cables on page 48 ).
One set of AMP connectors on the panel is for network ports 1 to 16, and the other set is for network ports 17 to 32.
Note: A set of connectors consists of one MAIN connector and one SPARE connector. When connecting to 16-port T1/E1 ASAP Adapter cards, always use the (bottom) connectors labeled MAIN.
Page 46 7705 SAR-8 Installation Guide
7705 SAR-8 Overview
Figure 10: BNC Distribution Panel
Front
1 2 3 4 5 6 7 8 RX 1 - 8
TX 1 - 8
RX 17-24
TX 17-24
17 18 19 20 21 22 23 24
9 10 11 12 13 14 15 16
RX 9 - 16
TX 9 - 16
RX 25-32
TX 25-32 25 26 27 28 29 30 31 32
Back
1
TX /
SPARE / EXT
RX 17 32 M4
TX / RX
MAIN
17 32 M2
TX /
SPARE /
RX 1 -
EXT
16 M4
TX / RX
MAIN
1 16 M2
1
2
19788
Key
1
2
Table 3: Distribution Panel Features
Description
Label
68-pin AMP connectors
RJ45 Distribution Panel
shows the RJ45 Distribution panel. Table 3
lists the panel features.
The RJ45 panel provides 100-ohm T1 or 120-ohm E1 access to 32 ports. On the customer side, each port has an RJ45 connector. On the equipment side, the panel has two sets of
68-pin AMP connectors for connection to two 16-port T1/E1 ASAP cards via 68-pin AMP to 68-pin AMP T1/E1 cables (see
). One set of AMP connectors on the panel is for network ports 1 to 16, and the other set is for network ports 17 to 32.
Note: A set of connectors consists of one MAIN connector and one SPARE connector. When connecting to 16-port T1/E1 ASAP Adapter cards, always use the (bottom) connectors labeled MAIN.
7705 SAR-8 Installation Guide Page 47
7705 SAR-8 Components
1 2
I/O
3 4
9 10
I/O
11 12
5 6
I/O
7 8
13 14
I/O
15 16
Figure 11: RJ45 Distribution Panel
Front
17 18
I/O
19 20
25 26
I/O
27 28
21 22
I/O
23 24
29 30
I/O
31 32
Back
TX /
SPARE
RX 17 -
/ EXT
32 M4
TX / RX
MAIN
17 32 M2
1 2
M3 /
SPARE
TX /
/ EXT
RX 1 - 16
M1 /
MAIN
TX / RX 1 - 16
1
19604
T1/E1 Cables
Installation Guide Name
68-pin AMP connector to open-ended wire
T1/E1 cable
68-pin AMP to 68-pin AMP
T1/E1 cable
describes the T1/E1 cables that are available for the 7705 SAR-8, and gives the name used in the various installation guides as well as the name used in the orderable parts catalog.
Table 4: T1/E1 Cables
Orderable Parts Name
T1/E1 Cable 28 AWG Open-ended 30m
T1/E1 Cable 28 AWG Open-ended 15m
T1/E1 Cable 26 AWG Open-ended 30m
T1/E1 Cable 26 AWG Open-ended 15m
Description
• 68-pin AMP connector to openended wire
• for equipment connection to telecom equipment
T1/E1 Cable for Distribution Panel, 1m • 68-pin AMP to 68-pin AMP connectors
• for equipment connection to a distribution panel
For pinout information on the cables listed above, refer to the 7705 SAR 16-port T1/E1
ASAP Adapter Card Installation Guide.
Page 48 7705 SAR-8 Installation Guide
7705 SAR-8 Overview
SAR System Installation Process
To install the 7705 SAR-8 system, perform the installation procedures in the following order:
Step 1.
Prepare the site.
Step 2.
Unpack the chassis.
Step 3.
Mount and ground the chassis.
Step 4.
Prepare and connect the DC input power cables.
Step 5.
Install the components.
Step 6.
Power up the system.
Step 7.
Connect the network cables.
Step 8.
Provision (preconfigure) the system.
7705 SAR-8 Installation Guide Page 49
SAR System Installation Process
Page 50 7705 SAR-8 Installation Guide
Site Preparation
In This Chapter
This chapter provides information about preparing your site to install a 7705 SAR-8:
•
•
System Specifications on page 54
→
Chassis Specifications on page 54
→
Environmental Specifications on page 54
→
Adapter Card Specifications on page 55
→
→
Fan Module Specifications on page 56
→
Component Power Consumption on page 56
→
Component Operating Requirements on page 57
•
Installation Locations on page 58
→
Chassis Location Requirements on page 59
•
Safety Considerations on page 61
→
→
→
→
→
→
7705 SAR-8 Installation Guide Page 51
Warnings and Notes
Warnings and Notes
Warning:
• Do not transport and relocate a 7705 SAR-8 chassis that has any cards or modules installed. To properly transport and relocate a 7705 SAR-8 chassis, do the following:
→ (optional) label cards and modules to facilitate reassembly
→ remove all CSMs, adapter cards, and the Fan module from the chassis
→ disconnect any connected power cables from the chassis
→ repackage the cards and modules in their original shipping containers for relocation
• The 7705 SAR-8 uses external circuit breakers or fuses as a disconnect means.
Disconnect both A and B feeds before servicing.
• Do not assume that power has been disconnected from a circuit. Be sure to disconnect power to the equipment rack and external cables before installing or removing the
7705 SAR-8.
• Do not install equipment that appears to be damaged.
• 7705 SAR-8 systems equipped with DC-input power supplies should be installed in restricted access areas, such as a dedicated equipment room or an equipment closet, in accordance with Articles 110-16, 110-17, and 110-18 of the National Electric Code
ANSI/ NFPA 70.
• This product complies with, and has been CE marked in accordance with, the European
Directive 99/05/EC (R&TTE) and 2004/108/EC (EMC).
• Failure to comply with the equipment rack and chassis instructions as outlined in
Installation Locations on page 58
and Chassis Location Requirements on page 59
will cause thermal failure.
• The 7705 SAR-8 uses a fiber-optic communications method and is a Class 1 laser product.
Only trained service personnel familiar with laser radiation hazards should install or remove fiber-optic cables and cards in this system.
Notes:
• Prepare the equipment rack and site before installing the router. Plan the router placement near the power sources and network interface connections.
• An empty 7705 SAR-8 chassis weighs approximately 8.5 lbs (3.8 kg).
• A fully loaded 7705 SAR-8 chassis with the heaviest components/cards weighs approximately 15 lbs (6.8 kg).
• Always install the heaviest equipment on the bottom of the rack to keep the center of gravity of the equipment rack as low as possible.
Page 52 7705 SAR-8 Installation Guide
Site Preparation
Notes: (continued)
• To provide necessary stability, ensure that the equipment rack is bolted to the floor. Ceiling brackets are useful to provide additional stability.
• The equipment rack must be properly grounded.
• Install components after the chassis is installed in the rack.
• Maintain a clearance of at least 2.5 in. (6.4 cm) at the front of the router for cable management.
• Maintain a clearance of at least 3 in. (7.6 cm) on each side to ensure adequate air intake and exhaust. When mounting the router in a rack, ensure that the rack complies with all
requirements outlined in Chassis Location Requirements on page 59 .
• The 7705 SAR-8 includes factory-installed rack-mounting brackets to mount in a 19-inch equipment rack.
7705 SAR-8 Installation Guide Page 53
System Specifications
System Specifications
Chassis Specifications
Table 5: 7705 SAR-8 Chassis Specifications
Parameter
Dimensions
(without mounting brackets)
Chassis weight (unpopulated) 8.4 lbs. (3.8 kg)
Chassis weight
(FAM, 2 x CSM, 2 x Ethernet cards, 4 x ASAP cards)
16.1 lbs. (7.3 kg)
Adapter card slots
Fan module slots
6
1
CSM slots
Mounting
Description
(3.50 x 17.48 x 9.84 in.) (H x W x D)
(8.89 x 44.4 x 25 cm)
2
Mount in a recommended 19-inch equipment rack
Rack-mount brackets are factory-installed for 19-inch
NEBS mounting
Environmental Specifications
Table 6: Environmental Specifications
Parameter
Normal operating temperature
Short-term operating temperature
(1)
Relative humidity
Short-term relative humidity
(1)
Altitude range
Description
5 to 45ºC (41 to 113ºF)
-5 to 55ºC (23 to 131ºF)
5 to 85% (non-condensing)
5 to 95%, not to exceed 0.024 lb of water per
1.0 lb of air (35 g of water per 1.0 cubic meter of air)
Between 197 ft. (60 m) below sea level and
5906 ft. (1800 m) above sea level (70kPa to
106kPa)
Page 54 7705 SAR-8 Installation Guide
Site Preparation
Parameter
Shock and vibration
Earthquake
Pollution degree
Table 6: Environmental Specifications (Continued)
(2)
Rated voltage (DC)
Description
Very low levels for continuous duration (similar to modern office building, for example)
Suitable for high risk areas (Zone 4/California, for short duration)
2
Operating voltage range (DC)
Heat dissipation (worst case configuration)
-48/-60 VDC (-60 VDC is for various European countries)
-40 to -75 VDC
190 Watts
Notes:
1. Short-term is a period of less than 96 consecutive hours and a total of no more than 15 days per year. This is equivalent to 360 hours per year, with short-term periods occurring no more than 15 times per year.
2. Pollution degree is as defined in IEC 60950.
Adapter Card Specifications
Table 7: Adapter Card Specifications
Parameter
Dimensions (H x W x D)
Weight
Description
(6.69 x 0.88 x 8.66 in.)
(17.0 x 2.24 x 22.0 cm)
0.84 lbs (0.38 kg) (16-port T1/E1 ASAP card)
0.77 lbs (0.35 kg) (8-port Ethernet card)
7705 SAR-8 Installation Guide Page 55
System Specifications
CSM Specifications
Parameter
Dimensions (H x W x D)
Weight
Table 8: CSM Specifications
Description
(6.69 x 0.88 x 8.66 in.)
(17.0 x 2.24 x 22.0 cm)
0.88 lbs (0.4 kg)
Fan Module Specifications
Table 9: Fan Module Specifications
Parameter
Dimensions (H x W x D)
Weight
Description
(3.32 x 0.88 x 8.66 in.)
(8.43 x 2.24 x 22.0 cm)
0.81 lbs (0.37 kg)
Component Power Consumption
Table 10: Component Power Consumption
Component Power (Watts)
(conservative estimate)
28 W
Chassis
(1)
(all fans operating, no adapter cards)
Fan module 28 W
Adapter cards a16-chds1 a8-eth
17 W
20 W
Note:
1. In Release 1.0, the chassis itself consumes no power because an external DC power supply provides system power. Thus, power consumption of the chassis with all fans operating is equivalent to the power consumption of the Fan module.
Page 56 7705 SAR-8 Installation Guide
Site Preparation
Refer to the 7705 SAR-8 adapter card installation guide s for more information on these components.
Component Operating Requirements
Table 11: 7705 SAR-8 Hardware Components for DC Operational Requirements
Component Minimum
Backplane (factory-installed) 1
Maximum
1
Field-Replaceable
N
Fan module
Adapter cards
DC power harness (1)
1
1
1
6
1 2
Y
Y
Y
Note:
1. DC power harnesses are available from Alcatel-Lucent. Each harness has two wires. Use two harnesses when redundant DC supplies are used. All power cables used on the 7705 SAR-8 chassis must meet your local safety codes.
7705 SAR-8 Installation Guide Page 57
Installation Locations
Installation Locations
The 7705 SAR-8 is intended to be installed in facilities that provide weather protection and a temperature-controlled environment. The facilities provide protection from mold growth, pest incursion, and precipitation. The 7705 SAR-8 is not intended for installation in outdoor facilities.
Warning: Follow the equipment rack manufacturer’s instructions for proper rack installation.
Failure to comply with the requirements and the location requirements outlined in this section and
Chassis Location Requirements on page 59 will impede proper airflow and will result in
the system overheating.
Airflow on the 7705 SAR-8 is defined as EC Class (S) SR-SL per GR3028. For proper thermal performance, the following conditions must be met.
• The rack must be constructed using channel or angle rack uprights that are at least
1.25 in. (3.2 cm) deep, 3 in. (7.6 cm) wide (maximum), and oriented away from the chassis such that no solid metal from the uprights is located immediately adjacent to the chassis side walls (see
).
Example: Telect 02008-02011 Series or Newton 0040140XXX Relay Racks.
• The rack must not be an unequal flange rack that has solid walls located immediately adjacent to the chassis side walls. This will cause thermal failure.
Example: Telect 02033-02036 series.
• For seismic applications, the rack must be a Telect Global Seismic Frame
(GS series).
• 7705 SAR-8 deployments in closed cabinets are not recommended. If closed cabinets must be used, they must not restrict shelf airflow in any way. Furthermore, they must not cause the shelf inlet bulk air temperatures to rise above those defined in GR-63 under worst case environmental conditions, including any preheating of the cabinet air by other equipment.
• The rail mounting holes in the equipment rack must align with the mounting holes on the chassis mounting brackets. The 7705 SAR-8 mounting brackets are factoryinstalled for a NEBS mount in a 19-inch rack.
Follow the equipment rack manufacturer’s instructions for proper rack installation.
Page 58 7705 SAR-8 Installation Guide
Site Preparation
Required tools:
• #2 Phillips screwdriver
• flathead screwdriver
• anti-static bags, mats, and packaging
• ESD wrist strap
Chassis Location Requirements
Allow at least 3 in. (7.6 cm) clearance on the sides of the chassis for proper airflow and at
least 2.5 in. (6.4 cm) in front for cable management. See Figure 12 .
Warning: Failure to comply with the location requirements outlined in
Installation Locations on page 58
and Chassis Location Requirements on page 59
will impede proper airflow and will result in thermal failure.
Note: The Fan module provides 120 CFM of airflow through the 7705 SAR-8 (8 fans at
14.8 CFM/fan).
Observe the following requirements when installing the system.
• Ensure that the chassis is located in an area that can provide an average inlet air temperature (bulk air temperature averaged over 1 year) no greater than 104°F
(40°C) under full system power loading combined with worst-case environmental deployment conditions per GR-63.
• Ensure that the 7705 SAR-8 system intake is not located immediately adjacent to the exhaust of another chassis such that preheated air above 40°C long term or 55°C short term (per GR-63) is drawn into the system.
• Ensure that the 7705 SAR-8 system intake is not located immediately adjacent to the intake of another chassis such that 7705 SAR-8 airflow is restricted in any way.
• Ensure that the inlet and exhaust of the chassis is free of obstructions from cabling,
mounting hardware, or other electronic equipment in the areas shown in Figure 12 .
7705 SAR-8 Installation Guide Page 59
Installation Locations
Figure 12: Chassis Clearance Requirements (View from Top)
2 Rear
3 3
2
3
Key
1
4
4
1
Front
4
Rack upright
19765
Table 12: Chassis Clearance Specifications
Description
Front: 2.5 in. (6.4 cm) required for cable management
Rear: No clearance required
Side: 3 in. (7.6 cm) minimum required for airflow
Rack upright: 5 in. (12.7 cm) maximum required for airflow
Page 60 7705 SAR-8 Installation Guide
Site Preparation
Safety Considerations
Placement
Warning:
• Install the 7705 SAR-8 in recommended equipment racks.
• Install in clean, dry, ventilated, and temperature-controlled rooms.
• Verify that the rack is properly bolted and braced and is properly grounded to a grounding electrode.
• Install the chassis in the equipment rack before installing components.
Grounding
Warning:
• The router and equipment rack must be properly grounded. Chassis ground cables are not included. Lack of proper grounding (earthing) of the equipment may result in a safety hazard and excessive electromagnetic emissions.
• Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD-preventive wrist or ankle strap connected to a nearby ground point that is connected to site grounding point (typically, the grounding stud on the 7705 SAR-8 , or a properly grounded rack or work bench).
• The 7705 SAR-8 includes a chassis ground stud on the mounting bracket attached to the right-hand side of the router (when viewed from the front). The chassis ground must be connected to the building ground, using either a direct connection or a ground bus.
• Before making the chassis ground connection, ensure that all power is OFF from the DC circuit. To switch the power OFF, locate the circuit breaker on the panel board that services the DC circuit and switch the circuit breaker to the OFF position.
Tip: For extra safety, you can tape the handle of the circuit breaker in the OFF position.
• Do not use the chassis ground wire connection on the chassis ground stud for any other purpose. That is, the washers and nut used to secure the chassis ground wire on the ground stud must only be used for that purpose.
• When wiring the unit, the chassis ground connection must always be made first and disconnected last.
7705 SAR-8 Installation Guide Page 61
Safety Considerations
The
7705 SAR-8
supports both Common Bonding Networks (CBN) and Isolated Bonding
Networks (IBN). The positive battery inputs (Batt A and Batt B) are floating inputs relative to digital or chassis ground within the chassis and on the CSM, the adapter cards, and the
Fan module.
To use the system in a CBN installation, the 0V RTN terminal must be connected to the frame ground on the rack in which the
7705 SAR-8
is installed. For IBN installations, no additional grounding is needed.
Warning: In an IBN installation, the 0V RTN terminal must be connected to the building ground at the source.
Warning: In a CBN installation, if you use the 7705 SAR-8 chassis ground stud (located on the right-hand side mounting bracket) to connect the 0V RTN terminal to the frame ground on the rack, then you must use a second nut on the stud to secure the attachment. The first nut is used to secure the building ground point wire to the chassis ground lug, which must be a single-purpose permanent connection. Refer to
Chassis Ground Wiring on page 73 .
Page 62 7705 SAR-8 Installation Guide
Site Preparation
Cabling
Warning:
• To comply with the GR-1089-CORE requirement R4-9 [31] standard for electromagnetic compatibility and safety, all intra-building ports are specified for use with cables that are shielded and grounded at both ends.
• To meet surge protection requirements, the shield must be grounded by attaching the shield to a convenient chassis ground point, using hardware suitable to provide a solid electrical and mechanical connection. In addition, ensure that there is sufficient strain relief to remove any mechanical strain on the ground connection due to cable movement.
• The intra-building port(s) of the equipment or sub-assembly is suitable for connection to intra-building or unexposed wiring or cabling only. The intra-building port(s) of the equipment or sub-assembly must not be metallically connected to interfaces that connect to the Outside Plant (OSP) or its wiring. These interfaces are designed for use as intrabuilding interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE) and require isolation from the exposed OSP cabling. The addition of primary protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
Connection to external OSP wiring must be made through an external CSU prior to exiting the building.
• Bare conductors must be coated with an appropriate antioxidant compound before crimp connections are made. All unplated connectors, braided strap, and bus bars must be brought to a bright finish and then coated with an antioxidant before they are connected.
• The 7705 SAR-8 is suitable for both DC-I and DC-C power configurations. However, when used in a DC-I configuration, the battery returns must remain isolated until they reach the main power bus.
Power
Danger:
• Only electrical service personnel should perform wiring and cabling to the system.
• All power to the equipment rack or cabinet should be disconnected before the installation.
• Power cable(s) must meet your local electric code requirements.
• An external circuit breaker no greater than 10A must be located within a readily accessible distance from the equipment. This is intended as the disconnect device.
• When removing the DC power harness from the system, first disconnect the power from the source and then disconnect the harness from the 7705 SAR-8.
7705 SAR-8 Installation Guide Page 63
Safety Considerations
DC Power Requirements
• A means of disconnect must be provided within 10 ft (3 m) of the 7705 SAR-8.
• A maximum 10A circuit breaker or fuse must be provided.
• A minimum #18 AWG power conductor must be used for each DC input connection.
Fan Module
The 7705 SAR-8 supports a field-replaceable Fan module housing eight fans. The Fan module is replaceable as a single unit; individual fans are not replaceable.
The 7705 SAR-8 cooling system requires a minimum of 3 in. (7.6 cm) of unrestricted, unobstructed airflow on each side of the chassis to function properly.
Warning:
Failure to comply with the location requirements outlined in Installation Locations on page 58
and in this section will impede proper airflow and will result in thermal failure.
Danger: When removing the Fan module for servicing or any other reason, wait until all fans have stopped rotating before continuing work.
Storage
To store an uninstalled 7705 SAR-8 or extra field-replaceable parts (if applicable), re-wrap the components in the original packaging and keep them in a dry, dust-free temperaturecontrolled environment.
Table 13: Storage Specifications
Parameter Description
Storage and shipping temperature From -40° to 158°F (-40° to 70°C)
Non-condensing relative humidity Within 5 to 95%
Page 64 7705 SAR-8 Installation Guide
Site Preparation
Compliance
Refer to Standards and Protocol Support on page 137 for compliance information.
7705 SAR-8 Installation Guide Page 65
Safety Considerations
Page 66 7705 SAR-8 Installation Guide
Installing the Chassis
In This Chapter
This chapter provides information on installing a 7705 SAR-8 chassis:
•
Unpacking the Chassis on page 68
→
Unpacking Precautions on page 68
•
Installing the Chassis in a Rack on page 70
→
Rack-Mounting the Chassis on page 70
•
Chassis Ground Wiring on page 73
→
Making the Ground Connection on page 73
7705 SAR-8 Installation Guide Page 67
Unpacking the Chassis
Unpacking the Chassis
The Control and Switching Module (CSM), adapter cards, Fan module, and cables are field-
installable and field-replaceable components. Refer to Installing the Components on page 83
for more details. The DC power connectors are part of the 7705 SAR-8 chassis and are not field-replaceable.
Warning:
If the 7705 SAR-8 is to be relocated at a later time, observe the following warning:
• Do not transport and relocate a 7705 SAR-8 chassis that has any cards or modules installed. To properly transport and relocate a 7705 SAR-8 chassis, do the following:
→ (optional) label cards and modules to facilitate reassembly
→ remove all CSMs, adapter cards, and the Fan module from the chassis
→ disconnect any connected power cables from the chassis
→ repackage the cards and modules in their original shipping containers for relocation
Unpacking Precautions
Review the following list to avoid injury and to prevent damage to the 7705 SAR-8.
• The shipping weight of the chassis is approximately 10 lbs. (4.5 kg) without any components installed.
• The chassis is shipped in a heavy corrugated cardboard container protected by foam end caps. Do not discard the packaging container and materials used in shipping.
The packing materials should be re-used if it is necessary to reship the router.
• Keep the chassis wrapped in the anti-static packaging until you are ready to install the router.
Page 68 7705 SAR-8 Installation Guide
Installing the Chassis
displays the components of a packed 7705 SAR-8 chassis.
Figure 13: Unpacking the 7705 SAR-8 Chassis
3
2
3
1
19600
2
3
Key
1
Table 14: Unpacking the 7705 SAR-8 Chassis
Description
Shipping container
7705 SAR-8 chassis (wrapped in an anti-static bag)
Foam end caps
To unpack the chassis, open the carton and follow these steps:
Caution: Lift the chassis by the bottom of the chassis. Do not put your hands inside a card slot to lift the unit.
Step 1.
Carefully lift the router out of the carton and place it on a flat surface.
The chassis shipping weight is approximately 10 lbs. (4.5 kg) without any components installed.
Step 2.
Remove the foam end caps on the sides of the router.
Step 3.
Remove the protective anti-static wrapping when you are ready to install the router.
7705 SAR-8 Installation Guide Page 69
Installing the Chassis in a Rack
Installing the Chassis in a Rack
Danger: Only trained and qualified personnel should install or replace this equipment.
Caution:
• Always wear an ESD-preventive wrist or ankle strap and always connect an ESD strap to a nearby ground point that is connected to the site grounding point (typically, the grounding stud on the 7705 SAR-8, or a properly grounded rack or work bench).
• Lift the chassis by the bottom of the chassis. Do not put your hands inside a card slot to lift the unit.
• When rack-mounting the chassis in an equipment rack, do not stack other 7705 SAR-8 units or any other equipment directly on top (where the bottom unit is supporting other devices). Each unit must be secured in the rack with the appropriate mounting apparatus.
Warning:
• Failure to comply with the location requirements outlined in Installation Locations on page
and
Chassis Location Requirements on page 59
will impede proper airflow and will result in thermal failure.
• Non-conductive coatings (such as lacquer and enamel) must be removed from threads and other contact surfaces to ensure electrical conductivity. Thread-forming screws with paint piercing washers may be used for this purpose during installation.
Rack-Mounting the Chassis
The 7705 SAR-8 router chassis is designed for installation in a 19-inch rack. The rack-
mount brackets are factory-installed. Figure 14 illustrates the installation of the chassis in a
rack.
It is easier to install the 7705 SAR-8 chassis in the rack with two people, one person to hold the router and one person to secure it to the rack.
Page 70 7705 SAR-8 Installation Guide
Figure 14: Installing the 7705 SAR-8 Chassis in a Rack
Installing the Chassis
1
3
SLOT ID
CSM A
MDA 1
CSM B
MDA 3
MDA 5
MDA 2
MDA 4
MDA 6
CSM
Stat Act
Pwr
Mgmnt Port
A16-CND31
Stat Act
Pwr
Port
Console
Ports 1-16
Sync
In Out
Fan
Batt A
Batt B
7705 SAR-8
Alarm
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
2
2
3
Key
1
4
Table 15: Rack-Mounting the 7705 SAR-8 Chassis
Description
Equipment rack
Rack-mounting screws
7705 SAR-8 chassis
Rack-mounting bracket
4
19640
7705 SAR-8 Installation Guide Page 71
Installing the Chassis in a Rack
Before you begin, verify that:
• the equipment rack is securely installed, anchored, and grounded. Refer to the rack manufacturer’s documentation for instructions.
• the power to the rack is OFF
Required tools:
• a torque driver for Phillips screws
To install the chassis in the rack:
Step 1.
Lift the 7705 SAR-8 from the bottom and position it in the rack. If two people are installing the chassis, position one person in front of the rack and one behind it.
Step 2.
Align the mounting holes on each bracket with the mounting holes on the rack rail.
Insert a screw into each mounting hole and tighten.
Step 3.
Ground the chassis to the building ground. See Chassis Ground Wiring (below).
Page 72 7705 SAR-8 Installation Guide
Installing the Chassis
Chassis Ground Wiring
To make sure that the equipment is connected to earth ground, use the following instructions to prepare the ground wire and make the connection. Ground wire is not provided. The length of the ground wire depends on the location of the router and proximity to the proper grounding facilities.
Caution: The 7705 SAR-8 chassis ground stud located on the right-hand side mounting bracket must be a single-purpose permanent connection to the earth (building) ground point.
Therefore, the connection requires its own washers and nut.
Note:
• When wiring the unit, the chassis ground connection must always be made first and disconnected last.
• All bare conductors must be coated with an appropriate antioxidant compound before crimp connections are made. All unplated connectors, braided strap, and bus bars must be brought to a bright finish and then coated with an antioxidant before connecting them.
• All surfaces that are used for intentionally grounding the 7705 SAR-8 must be brought to a bright finish and an antioxidant solution must be applied to the surfaces being joined.
Making the Ground Connection
Tools and hardware required:
• wire stripper
• wire cutter
• crimping tool
• torque driver for hex nut
• M4 ring lug
• minimum #18 AWG wire (green/yellow)
Figure 15: Preparing the Ground Wire
2
3
1
19641
7705 SAR-8 Installation Guide Page 73
Chassis Ground Wiring
2
3
Key
1
Table 16: Ground Wire Descriptions
Description
Copper ground wire with green/yellow shield (minimum #18 AWG)
Insulation stripped according to local safety code
Ring lug
Figure 16: Attaching the Chassis Ground Connector
4 5 6 5 3
3
2
1
Page 74
19599
5
6
3
4
Key
1
2
Table 17: Chassis Ground Connection
Description
Lance
Cable tie
Chassis ground stud
Nut
Star washer
Ring lug and chassis ground wire (green/yellow)
7705 SAR-8 Installation Guide
Installing the Chassis
To make the chassis ground connection:
Step 1.
Run a single length of minimum #18 AWG wire from the ground point (building ground or equipment ground bus) to the chassis ground stud. When routing the cable, ensure that there is enough extra wire to form a service loop at the chassis end in order to facilitate maintenance.
Step 2.
Using a wire-stripping tool, strip the insulation from the wire according to local
safety codes and crimp the ring lug to the wire ( Figure 15 ).
Step 3.
Remove the nut and star washers from the ground stud on the mounting bracket.
Step 4.
Place a star washer and the ring lug on the ground stud such that the wire runs down
the rack upright. Secure the lug with the second star washer and nut ( Figure 16 ).
Tighten the nut to a torque of 8-10 lbf-in. maximum. Do not over-tighten.
Step 5.
Use a cable tie to secure the ground wire to the lance on the mounting bracket.
Step 6.
Form a service loop with the extra wire and secure it to a convenient place (for example, a rack upright).
Step 7.
Connect the opposite end of the ground wire to the appropriate ground point at your installation site. Ensure that the chassis ground connection is made according to local safety codes.
Step 8.
Connect the 7705 SAR-8 to the DC power source. See DC Power Connections on page 77
.
7705 SAR-8 Installation Guide Page 75
Chassis Ground Wiring
Page 76 7705 SAR-8 Installation Guide
DC Power Connections
In This Chapter
This chapter provides information about wiring and connecting the DC power source to the
7705 SAR-8 :
•
Wiring and Connecting DC Power on page 78
→
•
DC-Input Power Connections on page 79
→
Wiring the DC Inputs on page 79
7705 SAR-8 Installation Guide Page 77
Wiring and Connecting DC Power
Wiring and Connecting DC Power
Warnings and Notes
Danger:
• Make the ground connections first.
• Only qualified personnel should install or replace this equipment.
• Confirm that the DC power source is OFF during installation. The power source should be a safety extra-low voltage (SELV) source.
• Turn off power at the power source before you install or remove power cables or cords.
• The unit should be connected to a DC branch circuit with a maximum 10A circuit breaker or fuse that meets the requirements for branch circuit protection. A suitable disconnect device must be provided in the DC branch, either a circuit breaker or switch that can be employed to disconnect power to the system during servicing.
• Before working on equipment that is connected to power, remove jewelry, such as rings, necklaces, and watches. When metal objects are in contact with power and ground, serious burns can occur or the objects can be welded to the terminals.
• You must use cables that meet local electrical code requirements.
Warning:
• Do not install equipment that appears to be damaged.
• The router and equipment rack must be properly grounded. Electrostatic discharge (ESD) damage can occur if components are mishandled.
• Always wear an ESD-preventive wrist or ankle strap and always connect an ESD strap to a nearby ground point that is connected to the site grounding point (typically, the grounding stud on the 7705 SAR-8, or a properly grounded rack or work bench).
• The 0V RTN terminal must always be connected to the building ground at the source.
• If the disconnect device for the 7705 SAR-8 is not permanently incorporated, a readily accessible disconnect device to shut off power during servicing must be incorporated in your building’s branch circuit.
Page 78 7705 SAR-8 Installation Guide
DC Power Connections
Note:
• The 7705 SAR-8 requires a minimum of one DC power source to operate, but using two
DC power sources is recommended for redundancy.
• The 7705 SAR-8 is suitable for both DC-I and DC-C power configurations.
• All bare conductors must be coated with an appropriate antioxidant compound before crimp connections are made. All unplated connectors, braided strap, and bus bars must be brought to a bright finish and then coated with an antioxidant before connecting them.
• To comply with the GR-1089-CORE requirement R4-9 [31] standard for electromagnetic compatibility and safety, all intra-building ports are specified for use with cables that are shielded and grounded at both ends.
DC-Input Power Connections
Warning:
• Ensure that all power is OFF from the DC circuit. Locate the circuit breaker on the panel board that services the DC circuit and switch the circuit breaker to the OFF position. For extra safety, you can tape the handle of the circuit breaker in the OFF position.
• When wiring the unit, the chassis ground connection must always be made first and disconnected last.
Wiring the DC Inputs
The
7705 SAR-8
has two D-Sub 2W2 connectors mounted on the front of the chassis. These connectors are the DC power feed points for DC source voltage from the DC circuit. A 13 ft
(4 m) wiring harness is available from Alcatel-Lucent to facilitate the DC source-to-router connection. The harness has a 2W2 connector at one end and open-ended wires at the other end.
For redundant power configurations, you must use two DC power feeds (one for each power connector on the 7705 SAR-8).
7705 SAR-8 Installation Guide Page 79
DC-Input Power Connections
Page 80
Each 2W2 connector is keyed to ensure proper attachment (one female and one male pin) and is secured with thumbscrews on the harness connector to prevent accidental removal.
shows the DC power harness.
Figure 17: DC Power Harness
2
2
1
1
19601
Key
1
2
Table 18: DC Power Connection Descriptions
Description
0V RTN (male pin on chassis, black wire, #12 AWG)
-VDC (female pin on chassis, blue wire, #12 AWG)
Required tools and hardware:
• one or two DC power wiring harnesses (3HE03400AA) (two harnesses are required for redundant power configurations)
• torque driver for slot screws
Follow these steps to wire and connect a DC power feed:
Step 1.
Ensure power has been disconnected from the DC power source end. Typically, this is done via a circuit breaker or another disconnect device.
Step 2.
Prepare the DC power harness at the DC power source end. Strip the wire insulation to the proper length according to your local safety codes.
Step 3.
Attach the -VDC (blue) and RTN (black) wires at the DC power source end according to local safety codes.
Step 4.
At the chassis end, attach the 2W2 connector on the wiring harness to the connector on the chassis.
Step 5.
Use a slot screwdriver to secure the chassis connection by tightening the screws on the 2W2 connector.
7705 SAR-8 Installation Guide
DC Power Connections
Step 6.
Secure the power harness to a rack upright within 6 inches (15.25 cm) of the power connection with a cable tie.
Step 7.
For redundant configurations, repeat steps 2 through 6 for the second DC power source.
Step 8.
Install the other
7705 SAR-8
components. See
Installing the Components on page 83 .
7705 SAR-8 Installation Guide Page 81
DC-Input Power Connections
Page 82 7705 SAR-8 Installation Guide
Installing the Components
In This Chapter
This chapter provides information about installing the components in the 7705 SAR-8:
•
Installing Components on page 84
→
→
→
→
→
•
Installing a Distribution Panel in a Rack on page 92
→
Rack-Mounting a BNC or RJ45 Distribution Panel on page 92
•
Managing Cable Connections to Adapter Cards on page 95
→
→
Ethernet and Copper Cables on page 96
→
→
Making a Shield Ground Connection on page 98
•
Making External Synchronization Connections on page 99
→
Connecting an External Synchronization Input on page 100
→
Providing an External Synchronization Output on page 100
7705 SAR-8 Installation Guide Page 83
Installing Components
Installing Components
The Control and Switching Module (CSM), adapter cards, Fan module, distribution panel, and cables are field-installable and field-replaceable components.
Warnings and Notes
Danger:
• Only trained and qualified personnel should install or replace this equipment.
• Use of procedures other than those specified in this Installation Guide can result in hazardous radiation exposure.
• Invisible laser radiation can be emitted from an adapter card aperture port when no cable is connected. Avoid exposure and do not stare into open apertures.
Warning:
• Electrostatic discharge (ESD) damage can occur if adapter cards are mishandled.
Always wear an ESD-preventive wrist or ankle strap connected to a nearby ground point that is connected to site grounding point (typically, the grounding stud on the
7705 SAR-8
, or a properly grounded rack or work bench).
• Always place components on an anti-static surface.
• Do not power up a 7705 SAR-8 until all components are installed and verified as having been installed correctly.
• Use only approved small form-factor pluggable (SFP) fiber-optic devices in adapter card ports.
Note:
• Ports cannot be configured until the adapter card is provisioned.
• Services cannot be configured until the ports are configured.
CSM
The CSM includes one compact flash memory device that can be used to copy and store system boot, software images, and configuration files and logs. The CSM is shipped with the compact flash memory device installed. The CSM provides the console and management interfaces to the 7705 SAR-8, as well as external synchronization input and output interfaces.
Page 84 7705 SAR-8 Installation Guide
Installing the Components
To maintain EMC compliance, cables that are shielded and grounded at both ends must be used with the Console, (Ethernet) Management, and Synchronization interfaces.
The 7705 SAR-8 cannot boot without a CSM installed. CSMs are installed in slots A and B.
Install a CSM in slot A for a simplex control configuration. Install two CSMs — one in slot A and another in slot B —
for a redundant control configuration. Figure 18 illustrates the
installation of a CSM in slot A.
Refer to CSM Connectors and LEDs on page 112
for a description of the CSM LEDs.
Refer to Replacing a CSM on page 119 for instructions on replacing a CSM.
Figure 18: Installing the CSM
CSM
Stat
Act
Pwr
Mgmnt Port
Console
MDA 1
MDA 3
MDA 5
MDA 2
MDA 4
MDA 6
Sync
In Out
CSM
Stat Act
Pwr
Sync
In Out
Fan
Batt A
Batt B
7705 SAR-8
Alarm
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
19603
2
3
Key
1
4
Table 19: CSM Installation Features
Description
CSM card
Slot guide
Captive screw
Ejector lever
Tools required:
• torque driver for Phillips screws
7705 SAR-8 Installation Guide Page 85
Installing Components
To install a CSM:
Step 1.
Remove the new CSM from the packaging. Do not touch the printed circuit board or connector pins.
Step 2.
Install the CSM. For simplex configurations, the CSM must be installed in slot A. For redundant configurations, install a CSM in slot A and in slot B.
With the ejector levers rotated inward, hold the CSM by the levers, align the card with the slot guides, and slide the card inward until the connectors are seated in the backplane and the faceplate is flush with the front of the chassis.
Note: If the CSM does not seat properly in the backplane, an ejector lever may not be completely rotated inward. Pull the card out half way, adjust the levers, and reinsert the card.
Step 3.
Secure the card in place by tightening the captive screws. Do not over-tighten. The recommended torque is 4-6 lbf.-in.
Note: The CSM cannot be removed if the captive screws are tightened. To remove the CSM, loosen the captive screws, rotate the ejector levers outward to loosen the backplane connectors, and pull the CSM out of the slot.
Fan Module
The Fan module has eight fans mounted on its circuit board. The Fan module must always be installed and fully operational while the 7705 SAR-8 is powered up. During routine maintenance and Fan module replacement, the system can operate safely for up to four
minutes without the Fan module installed. Figure 19 illustrates the installation of the Fan
module.
To maintain EMC compliance, cables that are shielded and grounded at both ends must be used with the Alarm interface.
Refer to
Fan Module Connectors and LEDs on page 114
for a description of the Fan module
LEDs.
Refer to Replacing the Fan Module on page 127
for information on replacing the Fan module.
The Fan module provides an alarm interface equipped with relays that can be used to trigger external alarm indicators. It also provides inputs that can be used to trigger the generation of alarms on the 7705 SAR-8 that indicate environmental or external alarm conditions. Refer to
External Alarms Port Pinouts on page 135
for pinout definitions.
Page 86 7705 SAR-8 Installation Guide
Installing the Components
Warnings and Notes
Warning:
• Always keep your fingers away from rotating fan blades.
• The Fan module is hot-swappable. The 7705 SAR-8 operates safely for up to four minutes while you replace the Fan module. If a longer maintenance time is required, power off the system to prevent over-heating conditions.
Note: In the event of a single fan failure, the remaining fans continue to run. This is sufficient to continue to provide adequate cooling for the system but the Fan module needs to be replaced as soon as possible. The individual fans are not field-replaceable.
Figure 19: Installing the Fan Module
1
SLOT ID
MDA 1
MDA 3
CSM B
MDA 2
MDA 5
MDA 4
MDA 6
Fan
Batt A
Batt B
7705 SAR-8
Alarms
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
2
3
19642
2
3
Key
1
Table 20: Fan Module Installation Features
Description
Slot guide
Captive screw
Threaded receptacle
7705 SAR-8 Installation Guide Page 87
Installing Components
Tools required:
• torque driver for Phillips screws
To install a Fan module:
Step 1.
Remove the Fan module from the packaging and place it on a flat anti-static work surface. Avoid touching the board components and connector pins.
Step 2.
Insert the Fan module into the Fan slot. Align the Fan module with the slot guides and the captive screw with the threaded receptacle.
Step 3.
Press the Fan module firmly into the slot. Make sure that the connectors are fully seated in the receptacle.
Step 4.
Secure the Fan module to the chassis, using a calibrated torque screwdriver set at
4-6 lbf.in. Do not over-tighten.
Adapter Cards
The 7705 SAR-8 system supports the following adapter cards:
• 16-port T1/E1 ASAP Adapter card
• 8-port Ethernet Adapter card
A maximum of up to six adapter cards may be installed on the 7705 SAR-8 in slots MDA 1 through MDA 6 (up to six 16-port T1/E1 ASAP Adapter cards or up to two 8-port Ethernet
Adapter cards). See Figure 5 on page 41
for slot identification. Figure 20
illustrates the installation of an adapter card.
The 8-port Ethernet Adapter card has two small form-factor pluggable (SFP) ports for
Gigabit Ethernet connections and six RJ45 ports for 10/100 BASE-T Ethernet connections.
For more information on installing an SFP, see SFPs on page 90
.
To maintain EMC compliance, cables that are shielded and grounded at both ends must be used with the adapter card interfaces. Use CAT5 shielded cables with Fast Ethernet interfaces and CAT5E shielded cables with Gigabit Ethernet interfaces.
Page 88 7705 SAR-8 Installation Guide
Installing the Components
Refer to Replacing Adapter Cards on page 122
for general information on replacing an adapter card. For information on replacing a specific adapter card, as well as information on its connectors and LEDs, refer to the appropriate adapter card installation guide .
Figure 20: Installing an Adapter Card
1
2
MDA 1
MDA 3
MDA 5
MDA 2
MDA 4
MDA 6
A16-CND31
Stat
Act
Pwr
Port
Ports 1-16
3
4
Fan
Batt A
Batt B
7705 SAR-8
Alarm
Critical
Major
Minor
External
Alarms
FAN
4
3
19643
3
4
Key
1
2
Table 21: Adapter Card Installation Features
Description
Slot guide
Threaded receptacle
Captive screw
Ejector lever
Tools required:
• torque driver for Phillips screws
To install an adapter card:
Step 1.
Remove the adapter card from the packaging and place on a flat anti-static work surface. Avoid touching board components and connector pins.
With the ejector levers rotated inward, hold the adapter card by the levers, align the card with the slot guides, and slide the adapter card into the slot (see
Note: If the adapter card does not seat properly in the backplane, an ejector lever may not be completely rotated inward. Pull the card out half way, adjust the levers, and reinsert the card.
7705 SAR-8 Installation Guide Page 89
Installing Components
Step 2.
Press the adapter card firmly into the slot. Make sure that the card connectors are seated in the backplane connectors and the faceplate is flush with the front of the chassis.
Step 3.
Tighten the captive screws to secure the card. Do not over-tighten. The recommended torque is 4-6 lbf.-in.
Note: The adapter card cannot be removed if the captive screws are tightened. To remove the adapter card, loosen the captive screws, rotate the ejector levers outward, and pull the adapter card out of the slot.
SFPs
A small form-factor pluggable (SFP) module can be installed on the following adapter cards:
• 8-port Ethernet Adapter card
illustrates the installation of an SFP. Refer to the appropriate adapter card installation guide for more information on SFPs and a list of available types supported by the adapter card.
Figure 21: Installing an SFP
SLOT ID
CSM A
MDA 1
MDA 3
CSM B
MDA 2
MDA 4
MDA 5 MDA 6
CSM
Stat
Act
Pwr
Mgmnt Port
A16-CHDS1
Stat Act
Pwr Port
Console
Ports 1-16
Sync
In Out
A8-ETN
Stat
Pwr
Link 1 Act
Link 2 Act
Link 3 Act
Link 4 Act
Link 5 Act
Link 6 Act
Link
Act Link
Act
7
CSM
Stat Act
Pwr
Mgmnt Port
A16-CHDS1
Stat Act
Pwr Port
A16-CHDS1
Stat Act
Console
Ports 1-16
Sync
In Out
A8-ETN
Pwr Port
Stat
Pwr
Ports 1-16
Link 1 Act
Link 2 Act
Link 3 Act
Link 4 Act
Link 5 Act
Link 6 Act
Link
Act Link
Act
7
8
Fan
Batt A
Batt B
7705 SAR-8
Alarm
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
1
Link 5 Act
Link 6 Act
Link
Act
7
Link
8
2
19667
Page 90 7705 SAR-8 Installation Guide
Installing the Components
Key
1
2
Description
SFP receptacle
SFP
Table 22: SFP Installation Features
To install an SFP:
Step 1.
Remove the SFP from the packaging and place it on a flat anti-static work surface.
Avoid touching any SFP components and connector pins.
Step 2.
Insert the SFP into the appropriate receptacle on the adapter card until it clicks in place.
7705 SAR-8 Installation Guide Page 91
Installing a Distribution Panel in a Rack
Installing a Distribution Panel in a Rack
Danger: Only trained and qualified personnel should install or replace this equipment.
Caution: When rack-mounting the distribution panel in an equipment rack, do not stack another panel or any other equipment directly on top of the panel. Each panel must be secured in the rack with the appropriate mounting apparatus.
Rack-Mounting a BNC or RJ45 Distribution Panel
The distribution panel is designed for installation in a 19-inch rack. Figure 22 illustrates the
installation of a distribution panel.
Note: There should be at least 1 RU of space above and/or below the 7705 SAR-8 to run cables from the faceplate connectors. It is not necessary for the space to be immediately above or below the 7705 SAR-8.
Figure 22: Installing a Distribution Panel in a Rack
1
3
1 2
I/O
3 4
9 10
I/O
11 12
5 6
I/O
7 8
13
14
I/O
15 16
2
17 18
I/O
19 20
25
26
I/O
27
28
21 22
I/O
23 24
29 30
I/O
31 32
4
19605
Page 92 7705 SAR-8 Installation Guide
Installing the Components
2
3
Key
1
4
Table 23: Rack-Mounting the Distribution Panel
Description
Equipment rack
Rack-mount screws
Distribution panel
Rack-mount bracket
Before you begin, verify that:
• the equipment rack is securely installed, anchored, and grounded. Refer to the rack manufacturer’s documentation for instructions.
• the power to the rack is OFF
Tools required:
• torque driver for Phillips screws
To install a distribution panel in the rack:
Step 1.
Attach the rack-mount brackets to the panel as shown in
.
Step 2.
Lift the panel and position it in the rack. Ensure that there is at least 1 RU of empty space above or below the 7705 SAR-8 to run cables. See
Connections to Adapter Cards on page 95 .
Step 3.
Align the mounting holes on each bracket to the mounting holes on the rack uprights.
Insert a screw into each mounting hole and tighten.
Step 4.
Ground the panel to the building ground using one of the methods described below.
a)
If a ground stud is present on the panel, see Chassis Ground Wiring on page 73
.
Warning: Some panels have a grounding tab riveted to the side of the chassis. Do not use the ground tab to make the building ground connection because it does not conform to GR-1089-CORE specifications. Using the grounding tab may result in equipment damage or loss of data.
7705 SAR-8 Installation Guide Page 93
Installing a Distribution Panel in a Rack b) Alternatively, the panel may be grounded to the rack through its mounting screws while adhering to the following requirements.
→ All surfaces that are used for intentionally grounding the panel must be brought to a bright finish and an antioxidant solution must be applied to the surfaces being joined.
→ Non-conductive coatings (such as lacquer and enamel) must be removed from threads and other contact surfaces to ensure electrical conductivity. Threadforming screws with paint piercing washers may be used for this purpose during installation.
Page 94 7705 SAR-8 Installation Guide
Installing the Components
Managing Cable Connections to Adapter Cards
All cable connections to adapter cards are made from the front of the 7705 SAR-8 . The adapter cards can be connected using Ethernet, copper, or fiber-optic cables. A distribution panel is needed to make coaxial cable connections. Refer to the appropriate adapter card installation guide for details on connecting to a specific adapter card.
Note:
• Alcatel-Lucent recommends leaving at least 1 RU of space above and/or below the
7705 SAR-8 to run cables from the faceplate connectors. It is not necessary for the space to be immediately above or below the 7705 SAR-8.
• Ensure cables are dressed such that they do not impede the insertion or removal of fieldreplaceable units (FRUs), such as CSMs, adapter cards, and the Fan module.
• To maintain EMC compliance, cables that are shielded and grounded at both ends must be used with the adapter card interfaces.
• To meet surge protection requirements, the cable shield must be grounded by attaching the shield to a convenient chassis ground point, using hardware suitable to provide a solid electrical and mechanical connection. In addition, ensure that there is sufficient strain relief to remove any mechanical strain on the ground connection due to cable movement.
Warnings and Notes
Danger: Only trained and qualified personnel should install or replace this equipment.
Warning:
• Electrostatic discharge (ESD) damage can occur if CSMs or adapter cards are mishandled. Always wear an ESD-preventive wrist or ankle strap connected to a nearby ground point that is connected to site grounding point (typically, the grounding stud on the
7705 SAR-8, or a properly grounded rack or work bench).
• Invisible laser radiation can be emitted from the adapter card aperture ports when no cable is connected. Avoid exposure and do not stare into open apertures.
• Do not power up a 7705 SAR-8 until all components are installed and verified as having been installed correctly.
• Use only approved small form-factor pluggable (SFP) fiber-optic devices in adapter card ports.
7705 SAR-8 Installation Guide Page 95
Managing Cable Connections to Adapter Cards
Ethernet and Copper Cables
illustrates how Ethernet and copper wire cables are routed on the
7705 SAR-8
.
Cables can be routed under or over the chassis.
Figure 23: Managing Cable Connections
A8-ETN
Stat
Pwr
Link 1 Act Link 2 Act
Link 3 Act Link 4 Act Link 5 Act
Link 6 Act
Link Act Link Act
7
A8-ETN
Stat
Pwr
Link 1 Act Link 2 Act
Link 3 Act Link 4 Act
Link 5 Act Link 6 Act
Link Act Link
Act
7 8 FAN
SLOT ID
CSM A
MDA 1
MDA 3
CSM B
MDA 2
MDA 4
MDA 5 MDA 6
CSM
Stat
Act
Pwr
Mgmnt Port
A16-CHDS1
Stat Act
Pwr Port
Console
Ports 1-16
Sync
In Out
A8-ETN
Stat
Pwr
Link 1 Act
Link 2 Act
Link 3 Act
Link 4 Act
Link 5 Act
Link 6 Act
Link Act
Link
Act
7
CSM
Stat Act
Pwr
A16-CHDS1
Stat
Act
Mgmnt Port
Console
Pwr Port
A16-CHDS1
Stat
Act
Pwr
Port
A8-ETN
Stat
Pwr
Ports 1-16
Ports 1-16
Link 1 Act
Link 2 Act
Link 3 Act
Link 4 Act
Link 5 Act
Link 6 Act
7
Sync
In
Out
Link Act
Link
Act
8
SLOT ID
CSM A
MDA 1
CSM B
MDA 3
MDA 5
MDA 2
MDA 4
MDA 6
CSM
Stat Act
Pwr
Mgmnt Port
Console
Sync
In Out
CSM
Stat Act
Pwr
Mgmnt Port
Console Sync
In
Out
Fan
Batt A
Batt B
7705 SAR-8
Alarm
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
19668
Hardware required:
• cable ties
To attach Ethernet and copper wire cables:
Step 1.
Attach the cable to the connector on the adapter card.
Step 2.
Route the cables under or over the chassis. If desired, loosely bundle the cables from each slot together using a cable tie. Do not over-tighten the cable tie.
Note: Dress the cables such that they do not impede the insertion or removal of field-replaceable units, including the Fan module.
Step 3.
Attach the cable to a distribution panel or appropriate connector.
Page 96 7705 SAR-8 Installation Guide
Installing the Components
Fiber Cables
Warning:
• Fiber cables are sensitive to bending, twisting and general over-exertion. Extreme caution is recommended when handling fiber cable.
• In order to ensure that the minimum fiber bend radius of 1.2 in. (30 mm) is maintained within the allowable space, an open-angled 90º boot such as TYCO 1374737-x or equivalent is recommended. The boots must be installed and oriented during fiber termination.
• Observe proper fiber connector handling with respect to the use of dust covers and cleaning.
Fiber-optic cables are routed in a similar fashion to Ethernet and copper wire cables (see
). Cables are routed under or over the chassis.
Hardware required:
• fiber cable boot (optional)
• cable ties (optional)
To attach fiber cables:
Step 1.
Attach the cable to the connector on the adapter card. If necessary, attach the fiber cable boot according to the manufacturer’s instructions.
Warning: Fiber cables are sensitive to bending, twisting and general overexertion. Extreme caution is recommended when handling fiber cable.
Step 2.
Route the cables under or over the chassis. If desired, loosely bundle the cables from each slot together using a cable tie. Do not over-tighten the cable tie.
Note: Dress the cables such that they do not impede the insertion or removal of field-replaceable units, including the Fan module.
Step 3.
Attach the fiber cable to a distribution panel or appropriate connector.
7705 SAR-8 Installation Guide Page 97
Managing Cable Connections to Adapter Cards
Making a Shield Ground Connection
To maintain EMC compliance, cables that are shielded and grounded at both ends must be used with the CSM, Fan module, and adapter card interfaces.
To meet surge protection requirements, the cable shield must be grounded to a convenient chassis ground point, such as the equipment rack.
Hardware required:
• wire stripper
• hardware for making the connection (such as a screw, star washer, and cable ties)
To make a shield ground connection:
Step 1.
Locate a convenient chassis ground point, such as the equipment rack.
Step 2.
Carefully strip enough insulation (outer jacket) off of the cable such that the exposed grounding wire can reach the chassis ground point. Ensure that there is enough stipped insulation to provide strain relief for the ground connection.
Caution: When stripping the cable insulation, avoid nicking the ground conductors or the insulation on the signal conductor. Nicks can weaken or break a conductor or expose a wire to a potential short circuit.
Step 3.
Separate the ground shield (braid, foil, and drain wire) from the signal conductors.
Step 4.
Securely attach the shield to the chassis ground point. Use a screw and star washer large enough to make a proper ground connection. Use proper cable dressing and strain relief techniques.
Page 98 7705 SAR-8 Installation Guide
Installing the Components
Making External Synchronization Connections
The CSM provides 1.0/2.3 coaxial connectors for external synchronization input and output.
For redundant CSM configurations, a Y-cable can be used to connect the Sync In connectors on both CSMs to the same external synchronization source. The Y-cable is available from
Alcatel-Lucent.
illustrates the use of a Y-cable for redundant Sync In connections.
Figure 24: Installing Redundant External Synchronization Inputs
1
SLOT ID
CSM A
MDA 1
CSM B
MDA 3
MDA 5
MDA 2
MDA 4
MDA 6
CSM
Stat Act
Pwr
Mgmnt Port
A16-CHDS1
Stat
Act
Pwr Port
Console
Ports 1-16
Sync
In Out
A8-ETN
Stat
Pwr
Link 1 Act
Link 2 Act
Link 3 Act
Link 4 Act
Link 5 Act
Link 6 Act
Link
Act Link
Act
7
2
CSM
Stat Act
Pwr
A16-CHDS1
Stat Act
Mgmnt Port
Pwr Port
A16-CHDS1
Stat Act
Pwr Port
A8-ETN
Stat
Console
Ports 1-16
Ports 1-16
Pwr
Link 1 Act
Link 2 Act
Link 3 Act
Link 4 Act
Link 5 Act
Link 6 Act
Link
Act
Link Act
7
Sync
In
Out
8
Fan
Batt A
Batt B
7705 SAR-8
Alarm
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
3
4
19602
2
3
Key
1
4
Table 24: Redundant External Synchronization Input Features
Description
Sync In — CSM A
Sync In — CSM B
Y-cable
From external synchronization source
Hardware required:
• coaxial cable with 1.0/2.3 coaxial connector (for single CSM systems)
• Y-cable available from Alcatel-Lucent (for redundant CSM systems)
7705 SAR-8 Installation Guide Page 99
Making External Synchronization Connections
Connecting an External Synchronization Input
To connect an external synchronization source input to the router:
Step 1.
For single CSM systems, attach the synchronization cable to the Sync In connector on the CSM.
For redundant CSM systems, attach the two branch connectors on the Y-cable to the
Sync In connectors on the CSMs — one connector for each Sync In connector.
Step 2.
Attach the other end of the synchronization cable to the external synchronization source.
Providing an External Synchronization Output
To provide an external synchronization source output from the router:
Step 1.
Attach the synchronization cable to the Sync Out connector on the CSM. In a redundant CSM system, either Sync Out connector can be used.
Step 2.
Attach the other end of the synchronization cable to the device requiring a synchronization source.
Page 100 7705 SAR-8 Installation Guide
Initializing and Provisioning
In This Chapter
This chapter provides information about initializing and provisioning the router:
•
Powering Up the Router on page 102
→
Power-Up and Initialization on page 102
→
Troubleshooting Initial Startup on page 103
•
Establishing Router Management Connections on page 105
→
Console Connection on page 105
→
→
•
Provisioning CSM and Adapter Card Parameters on page 108
→
Card and Card-Type Commands on page 108
→
MDA and MDA-Type Commands for Adapter Cards on page 109
7705 SAR-8 Installation Guide Page 101
Powering Up the Router
Powering Up the Router
Complete the steps in Wiring the DC Inputs on page 79 and
Installing the Components on page 83
before proceeding with the following instructions. Then power up the system and verify the LED activity of all components.
The primary copy of the 7705 SAR-8 TiMOS software is located on the compact flash memory device that is factory-installed on the CSM. The compact flash device is not fieldreplaceable.
Note:
• The DC-powered 7705 SAR-8 does not have a power switch or circuit breaker. The system is powered on by applying power from the DC power source. Typically, this is done via a circuit breaker or a disconnect device.
• Configurations and executable images can be stored on the compact flash memory device or an FTP file location.
• For proper thermal operation, ensure that slot covers are installed on all empty slots before powering up the router.
• You must have a console or Telnet connection to communicate with and provision the
7705 SAR-8. See
Establishing Router Management Connections on page 105 .
Power-Up and Initialization
To power up the router, follow these steps:
Step 1.
Turn on the power to the router at the remote DC power source(s) to initiate the boot process.
The Power LEDs on the CSM and adapter cards should be blue and the Batt A, Batt
B, and Fan LEDs on the Fan module should be green. If only one DC power source is used, only one Batt LED should be lit.
Step 2.
Verify that the system is initializing.
The system searches the compact flash device on the CSM (cf3) for the boot.ldr
file (also known as the bootstrap or boot loader file). The Status and Activity LEDs on the CSM blink green during initialization. After initialization (approximately 30 seconds), the Status LED and the Activity LED on the active CSM turn solid green; the Activity LED on the inactive CSM continues to blink green.
If the LEDS do not operate as described above, or if they blink and turn off, refer to
Troubleshooting Initial Startup on page 103
.
Page 102 7705 SAR-8 Installation Guide
Initializing and Provisioning
Step 3.
Verify the operational status of the router components by checking all the LEDs on the following components:
→
Fan module (refer to Fan Module Connectors and LEDs on page 114 )
→ CSM (refer to
CSM Connectors and LEDs on page 112
)
→ Adapter cards (refer to the appropriate adapter card installation guide)
Step 4.
After verifying the LEDs, establish communication with the router via the Console port. Refer to
Console Connection on page 105 .
Step 5.
Configuration Guide for detailed information.
Step 6.
(Optional at this time) Configure or modify the primary, secondary, or tertiary BOF file locations. Refer to
Telnet Connection on page 106 for reference information and
to the 7705 SAR OS Basic System Configuration Guide for detailed information.
Troubleshooting Initial Startup
If the system cannot load or cannot find the boot.ldr
file on the compact flash memory device (cf3), the system will continuously reboot in an attempt to successfully find and load the boot.ldr
file. In this happens, the CSM should be replaced and the faulty CSM returned to Alcatel-Lucent. The example below displays the output when the boot.ldr
file cannot be found.
Example: Rebooting display
Rebooting...
Alcatel 7705 Boot ROM. Copyright 2007 Alcatel-Lucent.
All rights reserved. All use is subject to applicable license agreements.
Build: X-0.0.I166 on Wed Aug 8 23:22:35 EDT 2007 by csabuild
Version: 0x1C
Processor core is xxxxXX
COLD boot on processor #1
?Preparing for jump to RAM...
Starting bootrom RAM code...
Boot rom version is v28
>>>Octeon BIST check passed.
>>>Testing SDRAM from 0x02200000 to 0x40000000
>>>Testing Compact Flash ... Slot Empty
Board Serial Number is 'NS073640003'
Platforms in BP EEProm is 0x8
Chassis type 9 (csa8) found in BP EEProm
Chassis Serial Number is 'A60511000005'
Searching for boot.ldr on local drives:
No disk in cf3
No disk in cf3
No disk in cf3
Error - file boot.ldr not found on any drive
Please insert CF containing boot.ldr. Rebooting in 5 seconds.
7705 SAR-8 Installation Guide Page 103
Powering Up the Router
When the system finds the boot.ldr
file, the system processes the initialization parameters from the BOF (boot option file). The BOF should be on the same drive as the boot.ldr
file. If the BOF cannot be found or loaded, then the system prompts the user for alternate image and configuration file locations.
When the image is successfully loaded, control is passed from the boot loader file to the image. The runtime image attempts to locate the configuration file as configured in the BOF.
The configuration file includes chassis, CSM, adapter card, and port configurations, as well as system, routing, and service configurations.
displays the compact flash directory structure and file names.
Figure 25: Files on the Compact Flash
Root bof.cfg
boot.ldr
config.cfg
TiMOS-m.n.Yz
both.tim
Files on the compact flash are:
• bof.cfg — Boot option file
• boot.ldr — Bootstrap image
• config.cfg — Default configuration file
• TiMOS-m.n.Yz: m — Major release number n — minor release number
Y: A — Alpha release
B — Beta release
M — Maintenance release
R — Released software z — Version number both.tim — Application image file
19644
Page 104 7705 SAR-8 Installation Guide
Initializing and Provisioning
Establishing Router Management Connections
There are two ways to access management of the 7705 SAR-8:
• Console connection
• Telnet connection
Console Connection
The console connector on the CSM is a male DB9 connector. To establish a console connection, you need the following:
• an ASCII terminal or a PC running terminal emulation software set to the parameters shown in
• a standard serial cable with a female DB9 connector
For pinout information, refer to
Console Port Pinouts on page 133 .
Parameter
Baud Rate
Data Bits
Parity
Stop Bits
Flow Control
Table 25: Console Port Default Settings
Value
115 200
8
None
1
None
CSM
Stat Act
Pwr
Mgmt Port
Figure 26: Console Port Connection
Console port
Console
Sync
In Out
19645
7705 SAR-8 Installation Guide Page 105
Establishing Router Management Connections
To establish a console connection:
Step 1.
Connect the terminal to the Console port on the front panel ( Figure 26 ) using the
serial cable.
Step 2.
Power on the terminal.
Step 3.
Establish the connection by pressing the <Enter> key a few times on your terminal keyboard.
Step 4.
At the router prompt, enter the login and password.
The default login is admin
.
The default password is admin
.
Telnet Connection
Telnet access provides the same options for user and administrator access as those available through the console port. You can access the router with a Telnet connection from a PC or workstation connected to the network once the following conditions are met:
• the router has successfully initialized
•
the Management port ( Figure 27 ) has been configured using the
bof>address command (see CLI Syntax )
CLI Syntax: bof address ip-address/mask [primary|secondary]
For more information about configuring router parameters, refer to the 7705 SAR OS Router
Configuration Guide. For pinout information, refer to
Management Port Pinouts on page
.
Figure 27: Management Port Connection
CSM
Management port
Stat Act
Pwr
Mgmt Port Console
Sync
In Out
19646
Page 106 7705 SAR-8 Installation Guide
Initializing and Provisioning
Running Telnet
After the IP parameters are configured, the CLI can be accessed with a Telnet connection.
To establish a Telnet connection, run a Telnet program and issue the Telnet command, followed by the IP address.
The following displays an example of a Telnet login:
C:\>telnet 192.168.1.xx1
Login: admin
Password: ########
ALU-1#
The default login is admin
.
The default password is admin
.
7705 SAR-8 Installation Guide Page 107
Provisioning CSM and Adapter Card Parameters
Provisioning CSM and Adapter Card Parameters
The CSM does not require provisioning. However, the IOM, which is a software module on the CSM, must be activated before any adapter cards and port parameters can be provisioned and configured. The IOM is activated using the card
and card-type
CLI commands to specify its slot number and card type. Adapter cards must be provisioned before their ports can be configured.
Notes:
• IOMs are specified using the card
and card-type
commands (items 1 and 2 in the list below).
• Adapter cards are provisioned and configured using the mda
and mda-type
commands
(items 3 and 4 in the list below).
Configure components in the following order:
1. Card slot number (use the card
command)
2. Card type
3. Adapter card slot number (use the mda
command)
4. Adapter card type
5. Ports
Card and Card-Type Commands
In the config
context, activate the IOM on the CSM using the card
and card-type
CLI commands to specify the IOM.
Note: For the 7705 SAR-8, when specifying the IOM, the slot number value is always 1 and the card type is always iom-1g.
Command
Step 1.
card slot-number
Step 2.
card-type card-type
Example card 1 card-type iom-1g
Page 108 7705 SAR-8 Installation Guide
Initializing and Provisioning
MDA and MDA-Type Commands for Adapter Cards
Note:
• In the config
context, adapter cards are identified by their mda-number , where the mda-number
is a number from 1 through 6. For example, an adapter card in slot MDA 4 is identified by mda-number 4.
• In the show
context, adapter cards are identified as “1/ n
”, where “1” is the slot number and “ n” is the mda-number . For example, the command show mda 1/5
displays information on the adapter card in slot MDA 5. For the 7705 SAR-8, the slot number is always 1.
• Adapter cards must be configured before their ports can be configured.
Adapter card slots with odd numbers are on the left side of the router (slots MDA 1, 3, and
5); adapter card slots with even numbers are on the right side (slots MDA 2, 4, and 6). See
, which identifies the slots.
After the IOM is activated, continue in the config
context with the following CLI commands to provision the adapter card(s).
Command
Step 1.
mda mda-number
Step 2.
mda-type mda-type
Step 3.
exit
Example mda 1 mda-type a8-eth exit
To provision additional adapter cards, continue the configuration process with Step 4:
Step 4.
mda mda-number
Step 5.
mda-type mda-type
Step 6.
exit mda 3 mda-type a16-chds1 exit
7705 SAR-8 Installation Guide Page 109
Provisioning CSM and Adapter Card Parameters
Example
The following example displays the card
, card-type
, mda
and mda-type
commands to specify the IOM as an iom-1g type, with an 8-port Ethernet Adapter card in slot MDA 1 and a 16-port T1/E1 ASAP Adapter card in slot MDA 2:
ALU-1>config# card 1
ALU-1>config>card# card-type iom-1g
ALU-1>config>card# mda 1
ALU-1>config>card>mda# mda-type a8-eth
ALU-1>config>card>mda# exit
ALU-1>config>card# mda 2
ALU-1>config>card>mda# mda-type a16-chds1
ALU-1>config>card>mda# exit
The CLI display for the configuration example above looks similar to the following:
ALU-1>config# info
. . .
---------------------------------------------echo "Card Configuration"
#--------------------------------------------card 1
card-type iom-1g
mda 1
mda-type a8-eth
exit
mda 2
mda-type a16-chds1
exit exit
----------------------------------------------
ALU-1>config#
To configure ports, refer to the Card and Port Configuration section of the 7705 SAR OS
Interface Configuration Guide .
Page 110 7705 SAR-8 Installation Guide
Appendix A: Connectors and
LEDs
In This Chapter
This chapter provides information on the connectors and LEDs seen on the front of the
7705 SAR-8 . There are no connectors or LEDs on the back of the unit:
•
CSM Connectors and LEDs on page 112
•
Fan Module Connectors and LEDs on page 114
•
Adapter Card Connectors and LEDs on page 116
7705 SAR-8 Installation Guide Page 111
CSM Connectors and LEDs
CSM Connectors and LEDs
identifies the connectors and LEDs on the CSM.
Figure 28: CSM Connectors and LEDs
CSM
7 2 3
Stat Act
Pwr
1
4
Mgmt Port
5
Console
6
Sync
In Out
7
19647
Key
1
2
3
Table 26 describes the connectors and LEDs on the CSM.
Label/Part
Pwr
Stat (Status)
Act (Active)
Table 26: 7705 SAR-8 CSM Connector and LED Descriptions
Sub category
—
Description
—
—
Blue: Indicates that power to the CSM is on
Unlit: Indicates that there is no power to the CSM or the power is faulty
Green (solid): Indicates that the CSM is operationally up and administratively up
Green (blinking): Indicates that the CSM is initializing the system
Amber: Indicates that the CSM is operationally down but administratively up, or that hardware is booting up
Unlit: Indicates that the CSM is operationally down and administratively down
Green (solid): Indicates the active CSM
Green (blinking): Indicates the standby CSM
Page 112 7705 SAR-8 Installation Guide
Appendix A: Connectors and LEDs
Key
4
5
6
7
Table 26: 7705 SAR-8 CSM Connector and LED Descriptions (Continued)
Label/Part Sub category
Description
Mgmt Port Connector The Ethernet Management port is provisioned with an RJ-45 port and used for the initial system startup as well as system configuration and monitoring. It supports both half and full duplex modes, and 10M/100M or autonegotiated communication.
Refer to Management Port Pinouts on page 132
for pinout assignments.
LEDs
Link
Data
The Link LED is located in the top left corner of the port and the Data
LED is located in the top right corner.
Amber (blinking): Indicates that the Ethernet link has Rx/Tx activity
Unlit: Indicates that the Ethernet link has no activity, or is down or disabled
Green: Indicates that there is a valid communications link
Unlit: Indicates that there is no communications link, or that the link is operationally down or disabled or shut down
Note: The Data LED is not affected by a Lamp Test
Console — The console port is provisioned with a DB9 male connector and is used for the initial system startup as well as system configuration and monitoring.
The console port is a Universal Asynchronous Receiver/Transmitter
(UART) port. Refer to
Console Port Pinouts on page 133
for pinout assignments.
Use an EIA/TIA-232 DTE console cable to connect a terminal to the console port. The factory default baud rate is 115.2KBaud, and can be reconfigured for 9.6, 19.2, 38.4, or 57.6 KBaud.
Sync In
Ejector lever
Out
—
The “In” synchronization port is provisioned with a 1.0/2.3 coaxial connector that can be used to receive an external synchronization input signal.
The “Out” synchronization port is provisioned with a 1.0/2.3 coaxial connector that can be used to provide an external synchronization output signal.
The ejector levers help insert and remove the CSM from its card slot.
When rotated outward, the levers release the CSM connectors from the backplane.
7705 SAR-8 Installation Guide Page 113
Fan Module Connectors and LEDs
Fan Module Connectors and LEDs
identifies the connectors and LEDs on the Fan module.
Figure 29: Fan Module Connectors and LEDs
1
2
4
7705 SAR-8
FAN
Batt A
Batt B
Alarms
Critical
Major
Minor
ACO/LT
External
Alarms
3
5
FAN
19648
Key
1
2
Table 27 describes the connectors and LEDs on the Fan module.
Label/Part
FAN
Batt A
Batt B
Table 27: 7705 SAR-8 Fan Module Connector and LED Descriptions
Sub category
—
Description
—
Green: Indicates that the fans are operational.
Amber: Indicates that there is a fan failure.
Unlit : Indicates that the fan has power failure.
Note: The FAN LED is not affected by a Lamp Test.
Green: Indicates that DC input power is present and operational.
Unlit: Indicates that the DC power supply is not installed or the DC power feed is not connected.
Note: The Batt A and Batt B LEDs are not affected by a Lamp Test.
Page 114 7705 SAR-8 Installation Guide
Appendix A: Connectors and LEDs
Key
3
4
5
Table 27: 7705 SAR-8 Fan Module Connector and LED Descriptions (Continued)
Label/Part
Alarms
ACO/LT
External
Alarms
Sub category
Critical
Description
Major
Red: Indicates that a critical condition exists, such as a fan failure or a power feed failure.
Unlit: Indicates that there are no critical alarm conditions.
Red: Indicates that a serious condition exists, such as an overtemperature condition or a full compact flash device.
Unlit: Indicates that there are no major alarm conditions.
Minor Amber: Indicates that a condition exists, such as a card removal or a synchronization reference failure.
Unlit: Indicates that there are no minor alarm conditions.
The Audible Alarm Cutoff/Lamp Test button has two functions.
When pressed, the Lamp Test is enabled and the following LED activity occurs: all activity and status LEDs on the chassis glow green; all port
LEDs on T1/E1 ASAP Adapter cards glow green; critical and major
Alarm LEDs glow red and the minor Alarm LED glows amber.
Note: The following LEDS are not affected by the Lamp Test:
Management port LEDs on the CSM; Fan and Battery A/B LEDs on the
Fan module; and all port LEDs on the Ethernet Adapter card.
When released, all LEDs on CSM(s) and MDAs return to their pre-Lamp
Test state. The Alarm LEDs become unlit until the next new alarm condition.
Connector The External Alarms port is a DB15 serial port. It can receive input signals from four external alarm devices and provide output signals through three sets of contacts. Refer to
External Alarms Port Pinouts on page 135
for pinout assignments.
7705 SAR-8 Installation Guide Page 115
Adapter Card Connectors and LEDs
Adapter Card Connectors and LEDs
Adapter card connectors and LEDs are described in the specific adapter card installation guide.
Page 116 7705 SAR-8 Installation Guide
Appendix B: Field-Replaceable
Units
In This Chapter
This chapter provides information about field-replaceable units (FRUs) in the 7705 SAR-8 chassis:
•
Warnings and Notes on page 118
•
•
Replacing Adapter Cards on page 122
•
Replacing the Fan Module on page 127
•
Installing a Slot Cover on page 130
7705 SAR-8 Installation Guide Page 117
Warnings and Notes
Warnings and Notes
Danger:
• Only trained and qualified personnel should install or replace this equipment.
• Use of procedures other than those specified in this Installation Guide can result in hazardous radiation exposure.
Warning:
• Electrostatic discharge (ESD) damage can occur if 7705 SAR-8 components are mishandled. Always wear an ESD-preventive wrist or ankle strap connected to a nearby ground point that is connected to site grounding point (typically, the grounding stud on the
7705 SAR-8, or a properly grounded rack or work bench).
• If power cables are connected to a circuit panel, always use caution when removing and replacing field-replaceable components.
• Always place router components on an anti-static surface.
• Slot covers are required in all empty slots to prevent excess dust accumulation and to help control airflow and electromagnetic interference.
Note: Unless stated otherwise in this installation guide, replacing an FRU requires modifying the configuration of the FRU before the FRU can be removed. Typically, this means using the shutdown
command to put the element(s) in an administratively “down” status.
Page 118 7705 SAR-8 Installation Guide
Appendix B: Field-Replaceable Units
Replacing a CSM
This section contains:
•
•
•
Warnings and Notes
Warning:
• Electrostatic discharge (ESD) damage can occur if 7705 SAR-8 components are mishandled. Always wear an ESD-preventive wrist or ankle strap connected to a nearby ground point that is connected to site grounding point (typically, the grounding stud on the
7705 SAR-8, or a properly grounded rack or work bench).
• Always place router components on an anti-static surface.
• Slot covers are required in all empty slots to prevent excess dust accumulation and to help control airflow and electromagnetic interference.
Note:
• When replacing CSMs, modifying the configuration is not required.
• The 7705 SAR-8 requires at least one CSM, which must be installed in slot CSM A. For redundancy, install a second CSM in slot CSM B.
• Do not force an adapter card into a CSM slot.
• Do not force a CSM into an adapter card slot.
• When removing a CSM, always use the ejector levers to make sure that the connector pins disconnect from the backplane.
• In a single CSM system, removing the active CSM causes the system to shut down. If you are not immediately installing a replacement CSM, cover the empty slot with a slot cover and power off the system until the CSM is replaced.
7705 SAR-8 Installation Guide Page 119
Replacing a CSM
Removing a CSM
Tools required:
• Phillips screwdriver
To remove a CSM:
Step 1.
Disconnect all cable connections to the CSM.
Step 2.
Use a Phillips screwdriver to loosen the captive screws that fasten the CSM to the chassis.
Step 3.
Simultaneously rotate the ejector levers outward to unseat the backplane connectors.
Step 4.
Pull the CSM out of the slot using the ejector levers. Place the CSM on an anti-static surface.
Step 5.
If you are not replacing the CSM immediately, install a slot cover to cover the empty
slot. Refer to Installing a Slot Cover on page 130 for instructions.
Replacing a CSM
Note: Each CSM has two ejector levers that release the card from the backplane connectors. During installation, the ejector levers must be rotated inward. The ejector levers must remain in the inward position while the card is installed in the chassis.
illustrates replacing a CSM.
Figure 30: Replacing a CSM
CSM
Stat Act
Pwr
Mgmnt Port
Console
SLOT ID
CSM A
MDA 1
MDA 3
CSM B
MDA 2
MDA 5
MDA 4
MDA 6
Sync
In
Out
CSM
Stat Act
Pwr
Sync
In Out
Fan
Batt A
Batt B
7705 SAR-8
Alarm
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
19603
Tools required:
• torque driver for Phillips screws
Page 120 7705 SAR-8 Installation Guide
Appendix B: Field-Replaceable Units
To replace a CSM:
Step 1.
Remove the old CSM from the chassis.
Step 2.
Remove the new CSM from the packaging. Do not touch the printed circuit board or connector pins.
Step 3.
Install the replacement CSM. With the ejector levers rotated inward, hold the CSM by the levers, align the card with the slot guides and slide the card into the slot until the connectors are seated in the backplane and the faceplate is flush with the front of the chassis.
Warning: Do not force a CSM into its slot if its connector pins to not mate smoothly with the backplane connectors. The card may not be seated properly and the pins can get damaged. Pull the card half way out and then reinsert it.
Step 4.
Secure the card in place by tightening the captive screws. Do not over-tighten. The recommended torque is 4-6 lbf.-in.
7705 SAR-8 Installation Guide Page 121
Replacing Adapter Cards
Replacing Adapter Cards
This section contains:
•
•
Changing the Adapter Card Configuration
•
•
Warnings and Notes
Danger:
• Electrostatic discharge (ESD) damage can occur if 7705 SAR-8 components are mishandled. Always wear an ESD-preventive wrist or ankle strap connected to a nearby ground point that is connected to site grounding point (typically, the grounding stud on the
7705 SAR-8, or a properly grounded rack or work bench).
• Invisible laser radiation can be emitted from the aperture ports of an adapter card when no cable is connected. Avoid exposure and do not stare into open apertures.
Warning:
• Always place components on an anti-static surface.
• Do not power up a 7705 SAR-8 until all components are installed and their installation verified.
• Use only approved small form-factor pluggable (SFP) fiber-optic devices in adapter card ports.
• Slot covers are required in all empty slots to prevent excess dust accumulation and to help control airflow and electromagnetic interference.
Note:
• Ports cannot be configured if the adapter card is not provisioned.
• Services cannot be configured if ports are not configured.
• Adapter card slots are numbered MDA 1 through 6.
• Adapter cards and their slots are identified on the CLI as mda
slots.
• When you remove an adapter card, always use the ejector levers to ensure that the connector pins disconnect from the backplane.
Page 122 7705 SAR-8 Installation Guide
Appendix B: Field-Replaceable Units
Changing the Adapter Card Configuration
If you replace an adapter card with a different type, you must change the configuration to reflect the new adapter card type prior to removing the installed card. Each active port must be shut down before you shut down and remove an adapter card configuration. If you replace an adapter card with the same type, no configuration change is necessary. Refer to the 7705
SAR OS Interface Configuration Guide for details on configuring cards and ports.
Issue the following commands in the config
context to shut down ports, remove the adapter card from the configuration, and change to an 8-port Ethernet Adapter card:
Command
Step 1.
port port-id *
Example port 1/1/5
Step 2.
shutdown shutdown
*NOTE: The port>shutdown
command must be repeated for all enabled ports on the adapter card.
Step 3.
exit
Step 4.
card slot-number
Step 5.
mda mda-slot
Step 6.
shutdown exit card 1 mda 1 shutdown
Step 7.
exit
Step 8.
no mda mda-slot exit no mda 1
Step 9.
mda mda-slot mda
Step 10.
mda-type mda-type
Step 11.
no shutdown
Step 12.
exit mda a8-eth no shutdown exit
7705 SAR-8 Installation Guide Page 123
Replacing Adapter Cards
Removing an Adapter Card
illustrates removing an adapter card.
Figure 31: Removing an Adapter Card
1
2
MDA 1
MDA 3
MDA 5
MDA 2
MDA 4
MDA 6
A16-CND31
Stat
Act
Pwr
Port
Ports 1-16
3
4
Fan
Batt A
Batt B
7705 SAR-8
Alarm
Critical
Major
Minor
External
Alarms
FAN
4
3
3
4
Key
1
2
Table 28: Adapter Card Installation Features
Description
Card guide
Threaded receptacle
Captive screws
Ejector lever
Tools required:
• Phillips screwdriver
19649
Page 124 7705 SAR-8 Installation Guide
Appendix B: Field-Replaceable Units
To remove an adapter card:
Step 1.
If you are replacing an adapter card with a different type, change the configuration to reflect the new adapter card type. See
Changing the Adapter Card Configuration on page 123
.
Step 2.
Disconnect all cables from the adapter card ports.
Step 3.
Use a Phillips screwdriver to loosen the adapter card captive screws.
Note: The adapter card cannot be removed if the captive screws are tightened.
Step 4.
Simultaneously rotate the ejector levers outward to release the adapter card connectors from the backplane receptacles.
Step 5.
Grip the adapter card by the ejector levers and slide the card out of the slot. Place the adapter card on an anti-static surface.
Step 6.
If you are not replacing the adapter card immediately, cover the adapter card slot with a slot cover. See
Installing a Slot Cover on page 130
for instructions on installing a slot cover.
Replacing an Adapter Card
illustrates the replacement of an adapter card. Table 28 on page 124 identifies the
installation features.
Figure 32: Replacing an Adapter Card
SLOT ID
CSM A
MDA 1
MDA 3
CSM B
MDA 2
MDA 5
MDA 4
MDA 6
A16-CND31
Stat Act
Pwr Port
Ports 1-16
Fan
Batt A
Batt B
7705 SAR
Alarm
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
19650
Tools required:
• torque driver for Phillips screws
7705 SAR-8 Installation Guide Page 125
Replacing Adapter Cards
To replace an adapter card:
Step 1.
Remove the replacement adapter card from the packaging and place on a flat antistatic work surface. Avoid touching board components and connector pins.
Step 2.
With the ejector levers rotated inwards, hold the adapter card by the levers, align the card with the slot guides, and slide the adapter card into the slot.
Step 3.
Press the adapter card firmly into the slot. Make sure that the card connectors are seated in the backplane connectors.
Step 4.
Secure the card in place by tightening the captive screws. Do not over-tighten. The recommended torque is 4-6 lbf.-in.
Step 5.
Check the Power LED on the adapter card faceplate. If the chassis is powered ON , the Power LED on the adapter card is lit (blue). Refer to the adapter card installation guide for information on LEDs for the specific adapter card.
Step 6.
Reconnect all previoulsy removed network cables to the adapter card ports.
Page 126 7705 SAR-8 Installation Guide
Appendix B: Field-Replaceable Units
Replacing the Fan Module
This section contains:
•
•
•
Warnings and Notes
Warning:
• Always keep your fingers away from rotating fan blades.
• The Fan module is hot-swappable. The 7750 SAR chassis operates safely for up to four minutes while you replace the Fan module. If a longer maintenance time is required, power off the system to prevent over-temperature conditions.
Note: In the event of a single fan failure, the remaining fans continue to run. This is sufficient to continue to provide adequate cooling for the system but the Fan module needs to be replaced as soon as possible. The individual fans are not field-replaceable.
7705 SAR-8 Installation Guide Page 127
Replacing the Fan Module
Removing the Fan Module
illustrates removing the Fan module.
Figure 33: Removing the Fan Module
SLOT ID
MDA 1
MDA 3
CSM B
MDA 2
MDA 5
MDA 4
MDA 6
Fan
Batt A
Batt B
7705 SAR-8
Alarms
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
19651
Tools required:
• Phillips screwdriver
To remove the Fan module:
Step 1.
Unpack the replacement Fan module from the protective packaging. Place the Fan module on an anti-static surface.
Step 2.
Use a Phillips screwdriver to loosen the captive screw on the Fan module faceplate.
Step 3.
Pull the Fan module halfway out of the chassis and allow the fans to stop spinning.
Caution: DO NOT put your fingers or any tool in the Fan module if the fans are still spinning.
Wait until the fans stop spinning (about 20 seconds) before completely removing the Fan module from its slot.
Step 4.
When the fans stop spinning, pull the Fan module completely out of the slot.
Page 128 7705 SAR-8 Installation Guide
Appendix B: Field-Replaceable Units
Replacing the Fan Module
illustrates replacing the Fan module.
Figure 34: Replacing the Fan Module
SLOT ID
CSM A
MDA 1
CSM B
MDA 3
MDA 5
MDA 2
MDA 4
MDA 6
Fan
Batt A
Batt B
7705 SAR-8
Alarms
Critical
Major
Minor
ACO/LT
External
Alarms
FAN
19652
Tools required:
• torque driver for Phillips screws
To replace the Fan module:
Step 1.
Hold the replacement Fan module by its edges, align it with the slot guides, and slide it into the slot.
Step 2.
Press the Fan module firmly into the slot. Make sure that the Fan module connectors are seated in the backplane connectors.
Step 3.
Secure the Fan module by tightening the captive screw. Do not over-tighten. The recommended torque is 4-6 lbf.-in.
Step 4.
Verify that the Batt A and/or Batt B LEDs on the Fan module faceplate are lit. When lit (green), the system is receiving power from power feeds A and/or B. At least one of the Batt LEDs must be lit. Refer to
Fan Module Connectors and LEDs on page 114
for more information on Fan module LEDs.
7705 SAR-8 Installation Guide Page 129
Installing a Slot Cover
Installing a Slot Cover
A slot cover must be installed in all empty chassis slots.
Tools required:
• slot screwdriver
To install a slot cover:
Step 1.
Align the slot cover and insert the cover into the chassis slot.
Step 2.
Tighten the two captive screws that fasten the slot cover to the chassis. Do not overtighten. Slot covers do not have backplane connectors.
Page 130 7705 SAR-8 Installation Guide
Appendix C: Pinout Assignments
In This Chapter
This chapter provides information about the pinout assignments for the port connectors on the 7705 SAR-8:
•
→
→
Management Port Pinouts on page 132
→
→
Console Port Pinouts on page 133
•
→
External Alarms Port on page 134
→
External Alarms Port Pinouts on page 135
→
•
Adapter Card Ports on page 136
7705 SAR-8 Installation Guide Page 131
CSM Ports
CSM Ports
The CSM has two ports: the (Ethernet) Management port and the Console port.
identifies these ports.
Figure 35: CSM Ports
CSM
Management port
Console port
Stat Act
Pwr
Mgmt Port Console
Sync
In Out
19653
Management Port
The Management port supports half and full duplex communication via 10/100 or autonegotiated Ethernet. The Management port provides a channel to download software and configuration images and manage the system. This port is provisioned with an RJ45 connector on the front panel. You must provide a CAT5 Ethernet cable to connect to the port.
Management Port Pinouts
Table 29 displays the Management port pin assignments.
2
3
4
5
6
Pin
1
Table 29: Ethernet Management Port Pinouts — RJ45 Female
Signal
TX+
TX-
Direction
Output
Output
Description
Differential transmit data
–
positive
Differential transmit data – negative
NC
NC
RX-
—
—
Input
Not connected
Not connected
Differential receive data – negative
Page 132 7705 SAR-8 Installation Guide
Appendix C: Pinout Assignments
Pin
7
8
Table 29: Ethernet Management Port Pinouts — RJ45 Female (Continued)
Signal
NC
NC
Direction
—
—
Description
Not connected
Not connected
Console Port
The Console port is a Universal Asynchronous Receiver/Transmitter (UART) port used to configure router and system parameters. It can also be used for monitoring purposes. The
Console port is enabled by default and is configured as DTE. The default baud rate is
115 200. This port has a DB9 male connector. Connect the Console port to a terminal using an EIA/TIA-232 serial cable.
Console Port Pinouts
Table 30 displays the Console port pin assignments. The Console port is configured for DTE
mode.
6
7
4
5
8
9
2
3
Pin
1
Signal
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
RI
Table 30: Console Port Pinouts — DB9 Male
Direction
Input
Input
Output
Output
Signal ground
Input
Output
Input
Input
Description
Data carrier detect
Receive data
Transmit data
Data terminal ready
Signal ground
Data set ready
Request to send
Clear to send
Ring indicator
7705 SAR-8 Installation Guide Page 133
Fan Module Port
Fan Module Port
identifies the connector for the External Alarms port on the Fan module.
Figure 36: Fan Module Port
7705 SAR-8
FAN
Batt A
Batt B
Alarms
Critical
Major
Minor
ACO/LT
External
Alarms
External Alarms port
FAN
19654
External Alarms Port
The External Alarms port provides access to three pairs of alarm output contacts and four alarm inputs. All alarm interfaces are rated for 5 VDC and 100 mA (source or sink). Each alarm input has a fixed severity associated with it — there is one Critical alarm input, two
Major alarm inputs, and one Minor alarm input (see Table 31
). State transitions on the inputs are debounced for 2 seconds.
You can display the status of the alarm inputs using the show chassis environment
CLI command.
The port uses a DB15 connector. You must provide an appropriate cable configured according to your alarm panel.
Page 134 7705 SAR-8 Installation Guide
Appendix C: Pinout Assignments
External Alarms Port Pinouts
Table 31 specifies the External Alarms port connector pinouts.
11
12
13
14
15
7
8
9
10
5
6
3
4
Pin
1
2
Table 31: External Alarms Port Pinouts
Signal
Alarm 1
Alarm 2 nc
Alarm output 3, pin 2
Alarm output 3, pin 1 nc
Ground nc
Alarm output 2, pin 2
Alarm output 2, pin 1
Alarm 3
Alarm 4 nc
Alarm output 1, pin 2
Alarm output 1, pin 1
Direction
Input
Input
—
Output
Output
—
Reference
—
Output
Output
Input
Input
—
Output
Output
Description
Critical alarm severity (fixed)
Major alarm severity (fixed)
Not connected
Contact opens on minor alarm
Contact opens on minor alarm
Not connected
Reference output for alarm inputs
Not connected
Contact opens on major alarm
Contact opens on major alarm
Major alarm severity (fixed)
Minor alarm severity (fixed)
Not connected
Contact closes on critical alarm
Contact closes on critical alarm
7705 SAR-8 Installation Guide Page 135
Adapter Card Ports
Alarm examples
Table 32 lists critical, major, and minor alarm examples.
Alarm Severity
Critical
Major
Minor
Table 32: Alarm Examples
Examples
• one or more fans have failed
• a power feed has failed
• a critical external alarm has been detected
• one or more adapter or CSM cards has reported an overtemperature condition
• a major external alarm has been detected
• a minor external alarm has been detected
Adapter Card Ports
Refer to the appropriate adapter card installation guide for port and pinout information on a specific adapter card.
Page 136 7705 SAR-8 Installation Guide
Standards and Protocol Support
Standards Compliance
IEEE 802.1p/q VLAN Tagging
IEEE 802.3 10BaseT
IEEE 802.3u 100BaseTX
IEEE 802.3x Flow Control
IEEE 802.3z 1000BaseSX/LX
Protocol Support
LDP
RFC 5036 LDP Specification
MPLS
RFC 3031 MPLS Architecture
RFC 3032 MPLS Label Stack Encoding
RFC 4379 Detecting Multi-Protocol Label
Switched (MPLS) Data Plane Failures
DIFFERENTIATED SERVICES
RFC 2474 Definition of the DS Field in the IPv4 and IPv6 Headers
RFC 2597 Assured Forwarding PHB Group
RFC 2598 An Expedited Forwarding PHB
RFC 3140 Per-Hop Behavior Identification Codes
TCP/IP
RFC 768 UDP
RFC 791 IP
RFC 792 ICMP
RFC 793 TCP
RFC 826 ARP
RFC 854 Telnet
RFC 1350 The TFTP Protocol (Rev. 2)
RFC 1812 Requirements for IPv4 Routers
PPP
RFC 1332 PPP IPCP
RFC 1661 PPP
RFC 1989 PPP Link Quality Monitoring
RFC 1990 The PPP Multilink Protocol (MP)
ATM
RFC 2514 Definitions of Textual Conventions and
OBJECT_IDENTITIES for ATM
Management, February 1999
RFC 2515 Definition of Managed Objects for ATM
Management, February 1999 af-tm-0121.000 Traffic Management Specification
Version 4.1, March 1999
ITU-T Recommendation I.610 - B-ISDN Operation and Maintenance Principles and Functions version
11/95
ITU-T Recommendation I.432.1 - B-ISDN usernetwork interface - Physical layer specification:
General characteristics
GR-1248-CORE - Generic Requirements for
Operations of ATM Network Elements (NEs). Issue
3 June 1996
GR-1113-CORE - Bellcore, Asynchronous Transfer
Mode (ATM) and ATM Adaptation Layer (AAL)
Protocols Generic Requirements, Issue 1, July 1994
PSEUDOWIRES
RFC 4385 Pseudowire Emulation Edge-to-Edge
(PWE3) Control Word for Use over an
MPLS PSN
RFC 4447 Pseudowire Setup and Maintenance
Using the Label Distribution Protocol
(LDP)
RFC 4448 Encapsulation Methods for Transport of
Ethernet over MPLS Networks
RFC 4717 Encapsulation Methods for Transport of
Asynchronous Transfer Mode (ATM) over MPLS Networks
7705 SAR-8 Installation Guide Page 137
Standards and Protocol Support
RFC 5086 Structure-Aware Time Division
Multiplexed (TDM) Circuit Emulation
Service over Packet Switched Network
(CESoPSN)
RFC 5085 Pseudowire Virtual Circuit Connectivity
Verification (VCCV): A Control
Channel for Pseudowires
RADIUS
RFC 2865 Remote Authentication Dial In User
Service
RFC 2866 RADIUS Accounting
SSH draft-ietf-secsh-architecture.txt SSH Protocol
Architecture draft-ietf-secsh-userauth.txt SSH Authentication
Protocol draft-ietf-secsh-transport.txt SSH Transport Layer
Protocol draft-ietf-secsh-connection.txt SSH Connection
Protocol draft-ietf-secsh- newmodes.txt SSH Transport Layer
Encryption Modes
TACACS+ draft-grant-tacacs-02.txt The TACACS+ Protocol
NETWORK MANAGEMENT
ITU-T X.721: Information technology- OSI-Structure of Management Information
ITU-T X.734: Information technology- OSI-Systems
Management: Event Report Management Function
M.3100/3120 Equipment and Connection Models
TMF 509/613 Network Connectivity Model
RFC 1157 SNMPv1
RFC 1907 SNMPv2-MIB
RFC 2011 IP-MIB
RFC 2012 TCP-MIB
RFC 2013 UDP-MIB
RFC 2138 RADIUS
RFC 2571 SNMP-FRAMEWORKMIB
RFC 2572 SNMP-MPD-MIB
RFC 2573 SNMP-TARGET-&-
NOTIFICATION-MIB
RFC 2574 SNMP-USER-BASED-SMMIB
RFC 2575 SNMP-VIEW-BASED ACM-
MIB
RFC 2576 SNMP-COMMUNITY-MIB
RFC 2665 EtherLike-MIB
RFC 2819 RMON-MIB
RFC 2863 IF-MIB
RFC 2864 INVERTED-STACK-MIB
RFC 3014 NOTIFICATION-LOG MIB
RFC 3273 HCRMON-MIB
RFC 3411 An Architecture for Describing Simple
Network Management Protocol (SNMP)
Management Frameworks
RFC 3412 Message Processing and Dispatching for the Simple Network Management
Protocol (SNMP)
RFC 3413 Simple Network Management Protocol
(SNMP) Applications
RFC 3414 User-based Security Model (USM) for version 3 of the Simple Network
Management Protocol (SNMPv3)
RFC 3418 SNMP MIB draft-ietf-disman-alarm-mib-04.txt
draft-ietf-mpls-ldp-mib-07.txt
IANA-IFType-MIB
Proprietary MIBs
TIMETRA-ATM-MIB.mib
TIMETRA-CAPABILITY-7705-V1.mib
TIMETRA-CFLOWD-MIB.mib
TIMETRA-CHASSIS-MIB.mib
TIMETRA-CLEAR-MIB.mib
TIMETRA-FILTER-MIB.mib
TIMETRA-GLOBAL-MIB.mib
TIMETRA-LDP-MIB.mib
TIMETRA-LOG-MIB.mib
TIMETRA-MPLS-MIB.mib
TIMETRA-OAM-TEST-MIB.mib
TIMETRA-PORT-MIB.mib
TIMETRA-PPP-MIB.mib
TIMETRA-QOS-MIB.mib
TIMETRA-ROUTE-POLICY-MIB.mib
TIMETRA-SAP-MIB.mib
TIMETRA-SDP-MIB.mib
TIMETRA-SECURITY-MIB.mib
TIMETRA-SERV-MIB.mib
TIMETRA-SYSTEM-MIB.mib
TIMETRA-TC-MIB.mib
Page 138 7705 SAR-8 Installation Guide
Numerics
16-port T1/E1 ASAP Adapter card cable connections
Ethernet and copper cables
fiber cables
changing the configuration
connectors
EMC compliance
installing
LEDs
operating requirements
ports
provisioning
MDA commands
parameters
removing
replacing
shield ground connection
specifications
storage specifications
7705 SAR-8 components
adapter cards
chassis
CSM
fan module
installation process
power connectors
storage specifications
8-port Ethernet Adapter card cable connections
Ethernet and copper cables
fiber cables
changing the configuration
connectors
EMC compliance
installing
LEDs
operating requirements
ports
provisioning
7705 SAR-8 Installation Guide
Index
MDA commands
MDA-type commands
parameters
removing
replacing
shield ground connection
specifications
storage specifications
A
adapter cards; See 16-port T1/E1 ASAP Adapter card, See 8-port Ethernet Adapter card
alarm examples
B backplane operating requirements
BNC Distribution panel
grounding
installing
C cables
CAT5 shielded cable
CAT5E shielded cable
T1/E1
chassis
clearance requirements
DC power
connections
DC power harness
wiring
ground wiring
ground wire description
grounding making the ground connection
installation cabling
choosing a location
DC power requirements
grounding
Page 139
Index placement
unpacking
installing rack-mounting
location requirements
slot identification
specifications
storage specifications
compact flash directory structure
file descriptions
components installing
connections console
Telnet
connector descriptions adapter cards
CSM
fan module
console port pinouts
critical alarm examples
CSM
compact flash
connectors
EMC compliance
external synchronization connections
faceplate
installing
IOM module provisioning
LEDs
operating requirements
ports
console port
console port pinouts
management port
management port pinouts
redundant configurations
removing
replacing
shield ground connection
simplex configurations
specifications
storage specifications
D
DB9 male port pinouts
DC inputs
DC power harness
operating requirements
DC power LEDs
DC-input power connections
distribution panels; See BNC Distribution panel,
D-Sub 2W2 connectors
E
EMC compliance
environmental specifications
Ethernet management port pinouts
external alarms port pinouts
external synchronization source input connections
source output connections
F fan module
airflow
alarm interface
connectors
EMC compliance
external alarms port
external alarms port pinouts
installing
LEDs
monitoring temperature
operating requirements
operation
removing
replacing
safety
shield ground connection
specifications
storage specifications
fan operation
field-replaceable units; see FRUs
FRUs adapter cards
CSM
fan module
Page 140 7705 SAR-8 Installation Guide
slot cover
storage specifications
G grounding ground connection
grounding the chassis
I initializing the system
troubleshooting
installation chassis location requirements
installing
7705 SAR-8 chassis
components
adapter cards
CSM
fan module
fan trays
SFPs
IOM card commands
card type commands
configuring components
provisioning
L
LED descriptions adapter cards
CSM
fan module
M major alarm examples
minor alarm examples
monitoring temperature
P power connections
consumption by component
power system
provisioning adapter card parameters
7705 SAR-8 Installation Guide
Index
CSM IOM module
R redundant configurations
RJ45 Distribution panel
grounding
installing
RJ45 female port pinouts
router initializing
powering up
troubleshooting initial startup
router management
console connection console port
default settings
establishing
Telnet connection access conditions
login
management port
running Telnet
S safety
cabling
fan module
grounding
placement
power
DC power requirements
SFPs
installing
simplex configurations
site preparation compliance
slot cover
installing
storage specifications
system specifications
adapter card specifications
chassis specifications
component operating requirements
CSM specifications
environmental specifications
Page 141
Index fan module specifications
power consumption
T
T1/E1 cables
temperature
troubleshooting system startup
U unpacking the chassis
Y
Y-cable
Page 142 7705 SAR-8 Installation Guide
Customer documentation and product support
Customer documentation
http://www.alcatel-lucent.com/osds
Product manuals and documentation updates are available through the Alcatel-Lucent Support
Documentation and Software Download service at alcatel-lucent.com. If you are a new user and require access to this service, please contact your Alcatel-Lucent sales representative.
Technical support
http://www.alcatel-lucent.com/support
Customer documentation feedback
© 2008 Alcatel-Lucent. All rights reserved.
3HE 03256 AAAA TQZZA Edition 01