AKM 251
IT PT GR MA SA
PRODUCT DESCRIPTION SHEET
1.
Removable panstand grids
2.
Medium burner
3.
Rapid electric hotplate
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Large burner control knob
8.
Small burner control knob
9.
Hotplate control knob
10.
Electric ignition button
11.
Hotplate operation lamp
Symbols
Shaded circle
Large flame
Small flame
Tap closed
Maximum opening/delivery
Minimum opening or reduced delivery
Operation of burners with electric ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame setting
• At the same time, press the button with
.
the star .
The spark plug gives out a spark that causes the burner to ignite.
If the burner fails to light, repeat the above steps.
Note:
— Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
Operation of the electric hotplate
• Set the knob to one of positions 1-6, which correspond to different temperatures.
• To switch off the hotplate, set the knob to position “0”.
5019 319 61181
DIMENSIONS OF COOKTOP AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CAT. II2H3+
Type of gas used Type of burner
NATURAL
GAS
(Methane) G 20 large medium small
LIQUID PETROLEUM
GAS
(Cylinder) G 30 large medium small
LIQUID PETROLEUM
GAS
(Cylinder) G 31 large medium small
Injector marking
128
94
76
85
65
50
85
65
50
Rated heat capacity
Pcs-kW
Rated consumption
3.00
1.65
1.00
3.00
1.65
1.00
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
0.60
0.35
0.30
0.60
0.35
0.30
Reduced heat capacity
Pcs-kW
0.60
0.35
0.30
min.
Gas pressure rat.
max.
17
20
25
20
28-30
37
25
35
45
Type of gas used
G 20 20 mbar
G 30 28-30 mbar
G 31 37 mbar
Appliance model
3 gas + 1 E
3 gas + 1 E
3 gas + 1 E
ELECTRIC HOTPLATE POWER: 1500 W.
Total rated heat capacity
Pcs-kW
5.65
5.65
5.65
Total rated consumption
538 l/h
411 g/h
403 g/h
Air required for burning m
3
/h
11.3
11.3
11.3