광고
광고
AKM 535
FR
3
1
9 6 7 8
PRODUCT DESCRIPTION SHEET
4
5
1.
Removable panstand grids
2.
Medium burner
3.
Rapid electric hotplate
4.
Large burner
5.
Small burner
6.
Medium burner control knob
7.
Large burner control knob
8.
Small burner control knob
9.
Hotplate control knob
10.
Electric hotplate operation lamp
Symbols
Shaded circle
Large flame and star
Small flame
Tap closed
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Operation of burners with electronic ignition
To light one of the burners:
Press the relative knob and turn it anticlockwise to the large flame and star setting .
At the same time keep the knob pressed against the control panel until the burner ignites.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Note:
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
Operation of the electric hotplate
Set the knob to one of positions 1-6 , which correspond to different temperatures.
To switch off the hotplate, set the knob to position 0 .
5019 319 53071
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
Important :
If the cooktop is installed over a built-in oven
without forced ventilation cooling, make sure there are air inlets and outlets to allow adequate aeration inside the cabinet. Figure A illustrates an assembly example.
INJECTORS TABLE
Type of gas used Type of burner
NATURAL GAS
(Methane) G 20
NATURAL GAS
(Groningue) G 25
LIQUID PETROLEUM
GAS
(Cylinder) G 30
LIQUID PETROLEUM
GAS
(Cylinder) G 31
Type of gas used large medium small large medium small large medium small large medium small
Appliance model
128
94
76
128
94
76
85
65
50
85
65
50
G 20 20 mbar
G 25 25 mbar
G 30 28-30 mbar
G 31 37 mbar
3 gas + 1 E
3 gas + 1 E
3 gas + 1 E
3 gas + 1 E
ELECTRIC HOT PLATE POWER: 1500 W.
Injector marking
Rated heat capacity
Pcs-kW
Rated consumption
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
308 l/h
170 l/h
103 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Total rated heat capacity Pcs-kW
5.65
5.24
5.65
5.65
Total rated consumption
538 l/h
581 l/h
411 g/h
403 g/h
FIG. A
CATEGORY II2E+3+
Reduced heat capacity
Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
min.
17
20
20
25
Gas pressure rat.
20
25
28-30
37 max.
25
30
35
45
Air required for burning m3/h
11.3
10.5
11.3
11.3