Whirlpool AKM 210/IX Hob Program Chart
Whirlpool AKM 210/IX offers four gas burners with different heat capacities to accommodate a variety of cooking needs. The large burner is ideal for boiling water or searing meat, while the medium and small burners can be used for tasks like simmering sauces or gently cooking fish.
The electronic ignition system makes lighting the burners quick and easy, with just a simple push of a button and turn of the knob. The removable panstand grids allow for easy cleaning and maintenance of the cooktop.
Reklam
Reklam
AKM 210
FR
PRODUCT DESCRIPTION SHEET
1.
Removable panstand grids
2-3.
Medium burners
4.
Large burner
5.
6.
Small burner
Medium burner control knob
7.
8.
Medium burner control knob
Large burner control knob
9.
Small burner control knob
10.
Electronic ignition button
Symbols
Shaded circle Tap closed flame and star flame delivery and electric ignition reduced delivery
Operation of burners with electronic ignition
To light one of the burners:
• Press the relative knob and turn it anticlockwise to the large flame and star setting .
• At the same time, press the button with the star .
The spark plug gives out a spark that causes the burner to ignite.
If the burner does not ignite, repeat the operations described above.
Note:
— Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Type of gas used Type of burner
NATURAL GAS
(Methane) G 20
NATURAL GAS
(Groningue) G 25
LIQUID PETROLEUM
GAS
(Cylinder) G 30
LIQUID PETROLEUM
GAS
(Cylinder) G 31 large medium small large medium small large medium small large medium small
Injector marking
128
94
76
128
94
76
85
65
50
85
65
50
Rated heat capacity
Pcs-kW
Rated consumption
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
308 l/h
170 l/h
103 l/h
218 l/h
120 l/h
73 l/h
214 l/h
118 l/h
71 l/h
Reduced heat capacity
Pcs-kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
min.
17
20
20
25
Gas pressure rat.
20
25
28-30
37 max.
25
30
35
45
Type of gas used
G 20 20 mbar
G 25 25 mbar
G 25 28-30 mbar
G 31 37 mbar
Appliance model
4 gas
4 gas
4 gas
4 gas
Total rated heat capacity
Pcs-kW
7.30
6.77
7.30
7.30
Total rated consumption
695 l/h
751 l/h
531 g/h
521 g/h
Air required for burning m
3
/h
14.6
13.5
14.6
14.6
5019 319 60131
İndir
Reklam