Whirlpool AKM 521/WH Hob Program Chart
Whirlpool AKM 521/IX/01 is a 4 gas burner cooktop with a removable panstand grid that provides a stable base for your pots and pans. It features a large burner for rapid boiling, two medium burners for everyday cooking, and a small burner for delicate tasks like simmering or melting. The cooktop has an electric ignition system for easy and safe lighting, and each burner is equipped with a safety device that automatically shuts off the gas supply if the flame goes out.
The cooktop is designed for use with natural gas (G20, G25) or liquid petroleum gas (G30, G31). The gas pressure and injector size must be adjusted to match the type of gas being used. The table in the instruction manual provides the correct injector size and gas pressure settings for each type of gas.
广告
广告
AKM 521
FR
PRODUCT DESCRIPTION SHEET
1.
Removable panstand grids
2.
Large burner
3-4.
Medium burners
5.
Small burner
6.
Medium burner control knob
7.
Medium burner control knob
8.
Large burner control knob
9.
Small burner control knob
Symbols
Shaded circle
Large flame and star
Small flame
Tap closed
Maximum opening/delivery and electric ignition
Minimum opening or reduced delivery
Operation of burners with safety device and electric ignition
To light one of the burners:
Press the relative knob and turn it anticlockwise to the large flame and star setting .
At the same time, keep the knob pressed against the control panel until the burners ignites.
After the burner has ignited, keep the knob pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations described above.
Note:
Should particular local conditions of the delivered gas make the ignition of the burner difficult, it is advisable to repeat the operation with the knob turned to the small flame setting .
The safety device of the burner shuts off the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc.).
5019 319 53091
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
Note: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance.
INJECTORS TABLE CATEGORY II2E+3+
Gas pressure mbar
Type of gas used
NATURAL GAS
(Methane) G20
NATURAL GAS
(Groningue) G25
LIQUID PETROLEUM
GAS
(Cylinder) G30
LIQUID PETROLEUM
GAS
(Cylinder) G31
Type of burner large medium small large medium small large medium small large medium small
Injector marking
100/mm
128
94
76
128
94
76
85
65
50
85
65
50
Rated heat capacity kW
Rated consumption
3.00
1.65
1.00
2.78
1.53
0.93
3.00
1.65
1.00
3.00
1.65
1.00
286 l/h
157 l/h
95 l/h
308 l/h
170 l/h
103 l/h
218 g/h
120 g/h
73 g/h
214 g/h
118 g/h
71 g/h
Reduced heat capacity kW
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
0.60
0.35
0.30
min.
17
20
20
25 rat.
20
25
28-30
37 max.
25
30
35
45
Type of gas used
G20 20 mbar
G25 25 mbar
G30 28-30 mbar
G31 37 mbar
Appliance model
4 gas
4 gas
4 gas
4 gas
Total rated heat capacity kW
7.30
6.77
7.30
7.30
Total rated consumption
695 l/h
751 l/h
531 g/h
521 g/h
Air required for burning m 3 /h
14.6
13.5
14.6
14.6
ELECTRIC SUPPLY: 230 V - 50 Hz