schmersal RSS36-AS Operating Instructions Manual
Annonce
Annonce
Operating instructions
Safety sensor
EN Operating instructions. . . . . . . . . . . . .pages 1 to 8
Original
RSS36-AS
6.4 Diagnostic signal periphery error . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.5 Read-out of the parameter port . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
7.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
7.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
9 EU Declaration of conformity
Content
1.2
Target group: authorised qualified personnel . . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Comprehensive quality insurance to 2006/42/EC . . . . . . . . . . . . . .2
2.6
Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.4 Switching distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .5
5
5.1 Programming the slave address . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.2
Configuration of the safety monitor . . . . . . . . . . . . . . . . . . . . . . . . .5
5.3 Status signal "safety release" . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.4 Actuator teaching / actuator detection . . . . . . . . . . . . . . . . . . . . . . .5
6.1 LED indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.3 Diagnostic information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
EN
1. About this document
1.1 Function
This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety switchgear. The operating instructions must be available in a legible condition and a complete version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only.
Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation.
The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating instructions manual, labelled with the caution or warning symbol above, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net.
The information contained in this operating instructions manual is provided without liability and is subject to technical modifications.
1
2
Operating instructions
Safety sensor
There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed.
1.6 Warning about misuse
In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded. The relevant requirements of the standard ISO 14119 must be observed.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
RSS36➀ -ST-AS➁
No. Option Description
➀
➁
AD
I1
I2
R
Actuator
RST36-1
RST36-1-R
RST36-1-AD01…15
Standard coding
Standard coding, actuator detection
Individual coding
Individual coding, re-teaching enabled
Without latching
With latching, latching force approx. 18 N
Without latching
With latching, latching force approx. 18 N without latching, with actuator detection
2.2 Special versions
For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version.
2.3 Comprehensive quality insurance to 2006/42/EC
Schmersal is a certified company to appendix X of the Machinery
Directive. As a result, Schmersal is entitled to autonomously conduct the conformity assessment procedure for the products listed in
Appendix IV of the MD without involving a notified body. The prototype test certificates are available upon request or can be downloaded from the Internet at www.schmersal.com.
2.4 Purpose
This non-contact, electronic safety sensor is designed for application in safety circuits and is used for monitoring the position of movable safety guards. In this application, the safety sensor monitors the position of hinged, sliding or removable safety guards by means of the coded electronic actuator.
The safety function consists of safely switching off the code transmission when the safety guard is opened and maintaining the safe switched off condition for as long as the safety guard is open.
The safety switchgears are classified according to
ISO 14119 as type 4 switching devices.
Designs with individual coding are classified as highly coded and are labelled with "Coding Level: High".
RSS36-AS
An AS-Interface Safety at Work component functions on the basis of an individual code generator (8 x 4 bit). This safety code is cyclically transmitted over the AS-i network and monitored by a safety monitor.
Safety sensors and actuators with latching (ordering suffix 'R') must always be used in pairs. The latching force (approx. 18 N) exercised by the permanent magnet keeps hatches and small guards closed, also in a de-energised condition.
The system can be used as a door end stop up to 5 kg at 0.25 m/s.
The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level.
The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards.
2.5 Technical data
Standards: IEC 60947-5-3, EN 62026-2,
ISO 14119, IEC 61508, ISO 13849-1
Working principle: RFID
Frequency band:
Transmitter output:
Coding level according to ISO 14119:
- I1-version:
- I2-version:
125 kHz max. -6 dBm high high
- Standard coding version: low
Material of the housings: Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Response time:
Duration of risk:
Time to readiness:
Switching frequency f:
Actuator:
Mechanical data
Execution of the electrical connection:
< 100 ms
< 200 ms
≤ 5 s
≤ 1 Hz
RST36-1, RST36-1-R, RST36-1-AD01…15
Mechanical life:
- when used as door stop:
M12 connector plug, 4 poles
≥ 1 million operations for safety guards ≤ 5 kg and actuating speed ≤ 0.25 m/s
12 mm
10 mm
20 mm
Typical switching distance s typ
:
- Assured switch-on distance s
- Hysteresis:
- Repeat accuracy R: ao
:
- Assured switch-off distance s ar
:
< 2.0 mm
< 0.5 mm
Latching force (R): approx. 18 N
Fixation sensor / actuator: 2 x M4 cylinder head screw with washers to
DIN 125A / form A
2.2 … 2.5 Nm Tightening torque of the fixing screws:
Ambient conditions
Ambient temperature:
Storage and transport temperature:
Resistance to shock:
Resistance to vibration:
−25 °C ... +70 °C
−25 °C ... +85 °C
30 g / 11 ms
10 … 55 Hz, amplitude 1 mm
Protection class: IP65 / IP67 / IP69 to IEC 60529
Protection class: III
Insulation values to IEC/EN 60664-1:
- Rated impulse withstand voltage U
- Rated insulation voltage U i imp
: 0.8 kV
: 32 VDC
- Overvoltage category: III
- Degree of pollution: 3
Electrical data - AS-Interface
AS-I voltage range:
AS-i power consumption:
AS-i device insulation:
AS-i specification:
- Version:
18.0 ... 31.6 VDC, protection against polarity reversal
≤ 100 mA internal short-circuit proof
V 3.0
- Profile: S-0.B.F.E
EN
Operating instructions
Safety sensor
AS-i inputs:
- Channel 1:
- Channel 2:
AS-i Outputs:
- DO 0 ... DO 3:
AS-i parameter bits:
- P0:
- P1:
- P2:
- P3:
Actuator detection (AD):
Data bits DI 0/DI 1 = dynamic code transmission
Data bits DI 2/DI 3 = dynamic code transmission
Databits condition static 0 or dynamic code transmission no Function
Actuator present
Hysteresis signal (FID)g
Tamper protection time active (FID)
Device error (FID)
- P0 … P3:
Parameter request:
Actuator number 0, 01 - 15
default value parameter request "1111" (0xF)
AS-i Input module address: 0
- preset to address 0, can be changed through
AS-interface bus master or hand-held programming device
LED switching conditions display: green/red LED (AS-i Duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected /
Yellow LED:
Tamper protection time active device condition (enabling status) / hysteresis signal / device error
For use in NFPA 79 Applications only. Only for use in
Pollution Degree 2 Environment. Adapters providing field wiring means are available from the manufacturer.
Refer to manufacturers information.
2.6 Safety classification
Standards: ISO 13849-1, IEC 61508
PL: e
Control Category: 4
PFH: ≤ 5.13 x 10 -10
PFD:
SIL:
Service life:
/ h
≤ 9.0 x 10 -5 suitable for SIL 3 applications
20 years
RSS36-AS
3. Mounting
3.1 General mounting instructions
Please observe the relevant requirements of the standards
ISO 12100, ISO 14119 and ISO 14120.
Ensure the safety sensor and actuator is mounted on a flat surface.
The universal mounting holes provide for a variable mounting by means of M4 screws (tightening torque 2.2 … 2.5 Nm).
The component can be mounted in any position. The labelled surfaces of the safety sensor and the actuator have to be opposite. The safety sensor must only be used within the assured switching distances
≤ s ao
and ≥ s ar
.
The safety component and the actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling, pinning).
To avoid any interference inherent to this kind of system and any reduction of the switching distances, please observe the following guidelines:
• The presence of metal chips in the vicinity of the sensor is liable to modify the switching distance.
• Keep away from metal chips.
• Minimum distance 100 mm between two safety sensors as well as other systems with same frequency (125 kHz)
3.2 Accessories
Sealing kit
• Ordering code 101215048
• 8 plugs and 4 washers
• to seal the mounting holes and as spacer
(approx. 3 mm) to facilitate the cleaning below the mounting surface
• also suitable as tampering protection for the screw fixings.
Kit tamper-proof screws
• 4 x M4x25 incl. washers, ordering code 101217746
• 4 x M4x30 incl. washers, ordering code 101217747
EN 3
4
Operating instructions
Safety sensor
3.3 Dimensions
All measurements in mm.
Safety sensor
78
74 2
RSS36-AS
The side allows for a maximum height misalignment (X) of sensor and actuator of ± 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm.
X
Y
Actuator
Coding Level: High
91
78
106
91
V2
V2
Alternative suitable actuators with different design: refer to www.schmersal.net.
3.4 Switching distance
Switching distances to IEC 60947-5-3:
Typical switching distance s typ
:
Assured switching distance s ao
Assured switch-off distance s ar
12 mm
: 10 mm
: 20 mm
There are new switch distances as per the table below owing to the necessity of technical modifications (V2).
Please check the design of your guard system following installation to ensure adherence to the secured switch distances (≤ s ao
and ≥ s ar
) in accordance with the specified values and adjust the guard system accordingly.
The positions of the designations V2 should be gleaned from the dimensional drawings under 3.3.
Switching distances in mm to IEC 60947-5-3
Sensor
RSS s typ s ao s ar s typ
Sensor
RSS V2 s ao s ar
Actuator
RST
12
10
16
12
10
20
Actuator
RST V2
12
8
16
12
10
20
With the combination of "old sensor - new actuator (V2)" there may be limitations in availability owing to the reduced s ao
(8 mm). This change has no affect on the performance level.
Latching versions X ± 5 mm, Y ± 3 mm.
The latching force will be reduced by misalignment.
Actuating curves
The actuating curves represent the typical switching distance of the safety sensor during the approach of the actuator subject to the actuating direction
Transverse misalignment
S [mm] 12
10
5
0
-20 -15 -10 -5 0 5 10 15 20
Y [mm]
Height misalignment
S [mm] 12
10
5
0
-24 -20 -15 -10 -5 0 5 10 15 20 24
X [mm]
Preferred actuation directions: from front or from side
3.5 Adjustment
The continuous signal of the yellow LED signals the actuator detection; the flashing of the yellow LED signals that the safety sensor is actuated in the hysteresis area.
Recommended Adjustment
Align the safety sensor and actuator at a distance of 0.5 x s ao
.
The correct functionality of both safety channels must be checked by means of the connected safety-monitoring module.
EN
Operating instructions
Safety sensor
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by authorised personnel in a de-energised condition.
The connection to the AS-Interface system is realised through an M12 connector. The M12 connector is A-coded. The wiring configuration of the M12 connector is determined as follows (to EN 62026-2):
Pin assignment M12 connector spare
4 3
AS-i -
AS-i +
1 2 spare
5. Functions and configuration
5.1 Programming the slave address
The slave address is programmed through the M12 connector.
Any address from 1 to 31 can be set by means of the AS-i bus master or a hand-held programming device.
5.2 Configuration of the safety monitor
The RSS36 AS can be configured in the ASIMON configuration software with the following monitoring devices (also refer to the
ASIMON manual). (also refer to the ASIMON manual)
Double channel dependent
• Synchronisation time: 0.1 s
• Optionally with startup test
• Optional with local acknowledge
The configuration of the safety monitor must be tested and confirmed by a qualified and authorised safety expert/safety engineer.
5.3 Status signal "safety release"
The "safety release" status signal from a Safety at Work slave can be cyclically queried by the control system through the AS-i master. To thiseffect, the 4 input bits with the varying SaW code of a Safety at
Work slave are evaluated through an OR operation with 4 inputs in the control system.
RSS36-AS
5.4 Actuator teaching / actuator detection
Safety sensors with standard coding are ready to use upon delivery.
Individually coded safety sensors and actuators will require the following "teach-in" procedure:
1. Switch the safety sensor's voltage supply off and back on.
2. Introduce the actuator in the detection range. The teach-in procedure is signalled at the safety sensor, yellow LED flashes (1 Hz).
3. After 10 seconds, brief cyclic flashes (3 Hz) request the switch-off of the operating voltage of the safety sensor. (If the voltage is not switched off within 5 minutes, the safety sensor cancels the
"teach-in" procedure and signals a false actuator by 5 red flashes).
4. After the operating voltage is switched back on, the actuator must be detected once more in order to activate the taught actuator code.
In this way, the activated code is definitively saved!
For ordering suffix -I1, the thus executed allocation of safety sensor and actuator is irreversible.
For ordering suffix -I2, the "teach-in" procedure for a new actuator can be repeated an unlimited number of times. When a new actuator is taught, the code, which was applicable until that moment, becomes invalid. Subsequent to that, an enabling inhibit will be active for ten minutes, thus providing for an increased protection against tampering.
The AS-i Duo LED will flash red/green until the expiration of the time of the enabling inhibit and the detection of the new actuator. In case of power failure during the lapse of time, the 10-minutes tampering protection time will restart.
Actuator detection (AD)
Device with actuator detection (AD) can emit the number of especially coded actuators through the parameter port.
In this way, a non-safe identification of the actuator is possible.
Through the 4 bits of the parameter port, the actuators with the numbers 01 - 15 can be detected and transmitted to the control.
If no actuator is detected, a 0 will be emitted.
Safety sensors and actuators with actuator detection must always be used in pairs.
Actuator RST36-1-AD01…15, 15 different actuators at the most
EN 5
6
Operating instructions
Safety sensor RSS36-AS
6. Diagnostic
6.1 LED indications
The LED's have the following meaning (to EN 62026-2):
LED green-red
(AS-i Duo LED):
Yellow LED:
AS-Interface supply voltage /
AS-Interface communication error /
Slave address = 0 /
Periphery error detected /
Enabling inhibit (tamper protection time) active
Device status (enabling status) / hysteresis signal / device error
6.2 Error
Errors, which no longer guarantee the safe functionality of the RSS36 AS electromagnetic interlock, cause the safety outputs to be switched off and are signaled through a flashing pattern of the red LED. (see table 2).
After fault rectification, the error message can be reset by opening and closing the relevant guard door. The safety outputs of the safety monitor can be switched back on, thus enabling the machine.
6.3 Diagnostic information
Table 1: Diagnostic information of the safety switchgear
The safety switch signals the operational state as well as errors through three coloured LED’s installed on the device.
System condition
Safety guard open
Guard door closed
LED green-red
AS-i duo-LED green green yellow
Status
Off on
Actuated in limit area red-green flashing
Enabling inhibit (tamper protection time) active red-green flashing
Internal device error / periphery error red-green flashing red AS-i error: slave address = 0 or communication error
1) refer to flash code
Flashes
Off
Flashes 1) depending on the condition
1
1
1
0 dynamically (authorised operation) static 0 static 0 static 0
Table 2: Error messages / flash codes yellow LED
Flash codes
(yellow)
4 flash pulses
5 flash pulses
Designation
Ambient temperature high
Actuator fault
Continuous signal Internal error
Autonomous switch-off after
0 min
0 min
0 min
Error cause
Ambient temperature too high: T > 70 °C incorrect or defective actuator
Device defective
6.4 Diagnostic signal periphery error
All error messages of the safety switchgear are also transmitted as a
"periphery error" to the control system through the AS-i master.
A "periphery error" (FID input of the AS-i chip) is signaled by the alternating red and green flashing of the AS-i duo LED on the AS-i device.
6.5 Read-out of the parameter port
The parameter port P0 to P3 of an AS-i slave can be read out through the control interface of the AS-i master (see component description) by means of the "Write parameter" instruction (with hexadecimal value F).
This (non-safe) diagnostic information from the reflected parameters or the answer to a "Write parameter instruction" can be used by the user for diagnostic purposes or for the control programme.
Diagnostic information (P0 … P3)
1
2
3
Parameter bit Condition = 1
0 Actuator in
Hysteresis signal (FID)
Enabling inhibit (tamper protection time) active (FID)
Error detected (FID)
Actuator detection (AD) P0 … P3
Parameter bit Condition = 1
0 … 3 Binary number actuator 01 - 15
0 = no actuator detected
EN
Operating instructions
Safety sensor
7. Set-up and maintenance
7.1 Functional testing
The safety function of the safety components must be tested.
The following conditions must be previously checked and met:
1. Fitting of the sensor and the actuator.
2. Fitting and integrity of the power cable.
3. The system is free of dirt and soiling (in particular metal chips).
7.2 Maintenance
In the case of correct installation and adequate use, the safety switchgear features maintenance-free functionality.
A regular visual inspection and functional test, including the following steps, is recommended:
1. Check the safety function
2. Check the fixing and integrity of the safety switchgear, the actuator and the cable
3. Remove possible metal chips.
Adequate measures must be taken to ensure protection against tampering, either to prevent tampering of the safety guard, for instance by means of replacement actuators.
Damaged or defective components must be replaced.
8. Disassembly and disposal
8.1 Disassembly
The safety switchgear must be disassembled in a de-energised condition only.
8.2 Disposal
The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations.
RSS36-AS
EN 7
Operating instructions
Safety sensor
9. EU Declaration of conformity
EU Declaration of conformity
Original K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component: RSS36-AS
See ordering code Type:
Description of the component: Non-contact safety sensor with integrated AS-i Safety at Work
Relevant Directives: Machinery Directive
RED-Directive
RoHS-Directive
2006/42/EC
2014/53/EU
2011/65/EU
Applied standards: EN 60947-5-3:2013,
EN 300 330 V2.1.1:2017,
EN ISO 14119:2013,
EN ISO 13849-1:2015,
EN 61508 parts 1-7:2010,
EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Notified body for the prototype test: TÜV Rheinland Industrie Service GmbH
Alboinstr. 56, 12103 Berlin
ID n°: 0035
EC-prototype test certificate: 01/205/5115.01/15
Person authorised for the compilation of the technical documentation:
Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue: Wuppertal, May 26, 2017
RSS36-AS
Authorised signature
Philip Schmersal
Managing Director
The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net.
K. A. Schmersal GmbH & Co. KG
Möddinghofe 30, D - 42279 Wuppertal
Postfach 24 02 63, D - 42232 Wuppertal
Phone: +49 - (0)2 02 - 64 74 - 0
Telefax: +49 - (0)2 02 - 64 74 - 1 00
E-Mail: [email protected]
Internet: http://www.schmersal.com
8 EN