Schmersal AZ 16 ST3-AS R Safety switch Operating Instructions
Advertisement
Advertisement
Operating instructions
Safety switches
EN
Operating instructions. . . . . . . . . . . . .pages 1 to 4
Original
AZ 16 AS
1. About this document
1.1 Function
This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety switchgear. The operating instructions must be available in a legible condition and a complete version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only.
Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation.
The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Content
1.2
Target group: authorised qualified personnel . . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5
Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 Programming the slave address . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2
Configuration of the safety monitor . . . . . . . . . . . . . . . . . . . . . . . . .3
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
8 EU Declaration of conformity
Caution: Failure to comply with this warning notice could lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating instructions manual, the country specific installation standards as well as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: products.schmersal.com.
The information contained in this operating instructions manual is provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed.
1.6 Warning about misuse
In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded. The relevant requirements of the standard EN ISO 14119 must be observed.
EN 1
2
Operating instructions
Safety switches
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden, the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
AZ 16 ➀ -AS➁
No. Option Description
➀
➁
ST1
ST2
ST3
R
R-2254
Connector in the middle
Connector at the right-hand side
Connector at the left-hand side without latching with latching 30 N with latching 5 N
Only if the information described in this operating instructions manual are realised correctly, the safety function and therefore the compliance with the Machinery Directive is maintained.
2.2 Special versions
For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version.
2.3 Purpose
The safety switch is used in AS-Interface systems (to EN 62026-2) for monitoring the position of moveable safety guards to EN 60947-5-1.
The combination of the AZ 16 AS safety switch, the AZ 15/16 actuator and safety monitor ensures the safe monitoring of the condition of the corresponding safety guard. To actuate the AZ 16 AS safety switch, only the coded AZ 15/16 actuators must be used.
The safety function consists in safely switching off the code transmission when the safety guard is opened and maintaining the safe switched off condition for as long as the safety guard is open.
An AS-Interface Safety at Work component functions on the basis of an individual code generator (8 x 4 bit). This safety code is cyclically transmitted over the AS-i network and monitored by a safety monitor.
The component status can be evaluated through a PLC with
AS-Interface master. The safety-related functions are enabled by means of the AS-i safety monitor.
The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level.
LED display
The LEDs have the following meaning:
Green LED: AS-Interface supply voltage
Red LED: AS-Interface communication error or slave address = 0
Yellow LED: Status enable
2.4 Technical data
AZ 16 AS
Standards: EN 62026-2, EN 60947-5-1,
IEC 61508, EN ISO 13849-1
Operating principle: electromechanical
Material of the housings: Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Mechanical data
Execution of the electrical connection:
Ambient conditions
Ambient temperature:
Storage and transport temperature:
Protection class:
M12 connector plug, 4 poles
−25 °C ... +60 °C
−25 °C ... +85 °C
IP67 to EN 60529
Electrical data - AS-Interface
AS-i supply voltage: 18.0 ... 31.6 VDC, protection against polarity reversal
AS-i power consumption:
AS-i specification:
≤ 50 mA
- Version: V 2.1
- Profile: S-0.B.E
AS-i inputs:
- Contact 1:
- Contact 2:
Data bits D0/D1 = dynamic code transmission
Data bits D2/D3 = dynamic code transmission
Databits condition static 0 or dynamic code transmission no function default value "1111" (0xF)
AS-i Parameter bits:
- P0 … P3:
Parameter request:
AS-i Input module address: 0
(2) red LED:
- preset to address 0, can be changed through
AS-interface bus master or hand-held programming device
LED switching conditions display
(1) green LED:
(3) yellow LED:
Supply voltage
Communication error or Slave address = 0
Device condition (Enabling status)
2.5 Safety classification
Standards: EN ISO 13849-1, IEC 61508
If a fault exclusion of a hazardous damage to the 1-channel mechanics is authorised and sufficient protection against tampering is ensured.
PL:
Control category:
PFH-value:
SIL:
Mission time:
SIL:
Mission time:
Basically suitable up to:
PL:
Control category:
PFH-value:
1.01 x 10 -7
1.14 x 10 -6 up to d up to 3
/ h for ≤ 100,000 operations / year up to 2
20 years up to c up to 1
/ h for ≤ 100,000 operations / year up to 1
20 years
3. Mounting
3.1 General mounting instructions
The mounting dimensions are indicated at the rearside. The enclosure must not be used as an end stop. Any mounting position. The mounting position however must be chosen so that the ingress of dirt and soiling in the used opening is avoided. The unused openings must be sealed by means of slot sealing plugs (AZ 15/16 -1476-1 available as accessory) after fitting.
Please observe the remarks of the standards EN ISO 12100,
EN ISO 14119 and EN ISO 14120.
Mounting of the actuators: See mounting instructions actuators.
The actuator must be permanently fitted to the guard system and protected against displacement by suitable measures
(tamperproof screws, gluing, drilling, pinning).
3.2 Dimensions
EN
Operating instructions
Safety switches
All measurements in mm.
AZ 16 AS
40
ST3
LED
ST1 ST2
5,5
M 12
30
13
9
AZ 16 AS safety switch
56
40
ø 5,5 16
M 12
52
27
AZ 15/16-B1 actuator
Radii over the wide edge of the actuator
Radii over the long edge of the actuator
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by authorised personnel in a de-energised condition.
The connection to the AS-Interface system is realised through an M12 connector. The M12 connector is A-coded. The wiring configuration of the M12 connector is defined as follows (to EN 62026-2): spare
4
AS-Interface +
1
3
2
AS-Interface spare
5. Configuration
5.1 Programming the slave address
The slave address is programmed through the M12 connector.
Any address from 1 to 31 can be set by means of the AS-i bus master or a hand-held programming device.
5.2 Configuration of the safety monitor
The AZ 16 AS must be configured in the monitoring device by default as a double channel forced module (refer to ASIMON manual).
Double channel forced
• Optionally with startup test
• Optional with local acknowledge
The configuration of the safety monitor must be tested and confirmed by a qualified and authorised safety expert/safety engineer.
6. Set-up and maintenance
6.1 Functional testing
The safety function of the safety components must be tested.
The following conditions must be previously checked and met:
1. Check the switch enclosure for damage
2. Fitting and integrity of the cable connections
3. Connect the AZ 16 AS to the AS-Interface network
4. Set the parameter outputs to "1111" (0xF)
5. Check the proper function of the AZ 16 AS system and AZ 15/16 actuator with configured safety monitor
6.2 Maintenance
In case of correct installation in accordance with the above-described instructions, the component requires little maintenance. A regular visual inspection and functional test, including the following steps, is recommended:
1. Remove particles of dust and soiling
2. Fitting and integrity of the cable connections
Adequate measures must be taken to ensure protection against tampering either to prevent tampering of the safety guard, for instance by means of replacement actuators.
Damaged or defective components must be replaced.
7. Disassembly and disposal
7.1 Disassembly
The safety switchgear must be disassembled in a de-energised condition only.
7.2 Disposal
The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations.
EN 3
Operating instructions
Safety switches
8. EU Declaration of conformity
EU Declaration of conformity
Original K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component: AZ 16 AS
See ordering code Type:
Description of the component: Safety switch for movable safety guards with integrated AS-i Safety at Work
Relevant Directives: 2006/42/EC
2014/30/EU
2011/65/EU
Machinery Directive
EMC-Directive
RoHS-Directive
Applied standards: EN 60947-5-1:2017
EN ISO 14119:2013
EN ISO 13849-1:2015
IEC 61508 parts 1-7:2010
Person authorised for the compilation of the technical documentation:
Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue: Wuppertal, August 3, 2020
AZ 16 AS
K.A. Schmersal GmbH & Co. KG
Möddinghofe 30, 42279 Wuppertal
Germany
Phone: +49 202 6474-0
Telefax: +49 202 6474-100
E-Mail: [email protected]
Internet: www.schmersal.com
4
Authorised signature
Philip Schmersal
Managing Director
The currently valid declaration of conformity can be downloaded from the internet at products.schmersal.com.
EN
Download
Advertisement