Dell Chassis Management Controller Version 3.1 enables secure, end-to-end management of Dell PowerEdge rack servers. It provides comprehensive hardware management capabilities for configuring, monitoring, updating, and troubleshooting servers both in-band and out-of-band. With its advanced security features, you can rest assured that your servers are protected from unauthorized access and malicious threats. The CMC's intuitive web interface and industry-standard command-line interface (CLI) make it easy to manage your servers remotely, even when they are powered off or the operating system is unavailable.
advertisement
Dell Chassis Management
Controller Firmware
Version 3.1
User Guide
Notes and Cautions
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed.
____________________
Information in this publication is subject to change without notice.
© 2010 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell™, the DELL logo, FlexAddress™ , OpenManage™,
PowerEdge™ , and PowerConnect™ are trademarks of Dell Inc. Microsoft
®
Explorer ® , Windows ® , Windows Server ® , and Windows Vista ®
, Active Directory
®
, Internet are either trademark s or registered trademarks of Microsoft Corporation in the United States and other countries. Red Hat
®
Enterprise Linux ®
and Red Hat
are registered trademarks of Red Hat, Inc. in the United States and other countries.
Novell
®
is a registered trademark and SUSE ™ is a trademark of Novell Inc. in the United States and other countries. Intel ® is a registered trademark of Intel Corporation. UNIX ® is a registered trademark of The
Open Group in the United States and other countries. Avocent
®
OSCAR ®
is a trademark of Avocent Corporation.
is a registered trademark of Avocent Corporation or its affiliates.
Copyright 1998-2006 The OpenLDAP Foundation. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted only as authorized by the OpenLDAP Public
License. A copy of this license is available in the file LICENSE in the top-level directory of the distribution or, alternatively, at http://www.OpenLDAP.org/license.html
. OpenLDAP is a registered trademark of the
OpenLDAP Foundation. Individual files and/or contributed packages may be copyrighted by other parties and subject to additional restrictions. This work is derived from the University of Michigan LDAP v3.3 distribution. This work also contains materials derived from public sources. Information about OpenLDAP can be obtained at http://www.openldap.org/ . Portions Copyright 1998-2004 Kurt D. Zeilenga. Portions
Copyright 1998-2004 Net Boolean Incorporated. Portions Copyright 2001-2004 IBM Corporation. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted only as authorized by the OpenLDAP Public License. Portions Copyright 1999-2003 Howard
Y.H. Chu. Portions Copyright 1999-2003 Symas Corporation. Portions Copyright 1998-2003 Hallvard B.
Furuseth. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that this notice is preserved. The names of the copyright holders may not be used to endorse or promote products derived from this software without their specific prior written permission. This software is provided "as is'' without express or implied warranty. Portions Copyright (c)
1992-1996 Regents of the University of Michigan. All rights reserved. Redistribution and use in source and binary forms are permitted provided that this notice is preserved and that due credit is given to the University of Michigan at Ann Arbor. The name of the University may not be used to endorse or promote products derived from this software without specific prior written permission. This software is provided "as is'' without express or implied warranty.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
December 2010
Contents
1 Overview
. . . . . . . . . . . . . . . . . . . . . . . . .
19
19
20
. . . . . . . . . . . . . . . . . . . .
21
. . . . . . . . . . . . . . . . . . . .
22
. . . . . . . . . . . . . . . .
23
TCP/IP Ports . . . . . . . . . . . . . . . . . . . .
23
Supported Remote Access Connections
24
. . . . . . . . . . . . . . . . . . .
24
. . . . . . . . . . . . . . . .
25
. . . . . . . . . . . . . . . . . . . . . . .
25
. . . . . . . . . . . . . . . .
25
27
2 Installing and Setting Up the CMC
29
. . . . . . . . . . . . . . . . . . . .
29
29
Checklist for Integration of a Chassis
30
Contents 3
4 Contents
Basic CMC Network Connection . . . . . . . . . .
30
Daisy-chain CMC Network Connection . . . . . .
31
Installing Remote Access Software on a
. . . . . . . . . . . . . . . . . . .
35
Linux Management Station . . . . . . . . . . . . .
35
Linux Management Station . . . . . . . . . . . . .
36
36
. . . . . . . . . . . . . . . . . . . .
37
38
Certificate Revocation List (CRL)
Fetching . . . . . . . . . . . . . . . . . . . . . . .
38
Downloading Files From CMC With
Internet Explorer . . . . . . . . . . . . . . . . . .
39
Allow Animations in Internet Explorer
39
Setting Up Initial Access to the CMC
39
Configuring the CMC Network . . . . . . . . . . .
40
Configuring Networking Using the
41
Accessing the CMC Through a Network
48
Installing or Updating the CMC Firmware
49
Downloading the CMC Firmware . . . . . . . . . .
49
Updating CMC Firmware Using the
. . . . . . . . . . . . . . . . . . . .
50
Updating the CMC Firmware Using
RACADM . . . . . . . . . . . . . . . . . . . . . .
50
51
Configuring Power Budgeting . . . . . . . . . . .
51
Configuring CMC Network Settings
51
52
Adding SNMP and E-mail Alerts . . . . . . . . . .
52
Configuring Remote Syslog . . . . . . . . . . . . .
52
Understanding the Redundant CMC Environment
53
53
54
Redundant CMC . . . . . . . . . . . . . . . . . .
54
3 Configuring CMC to Use Command
Line Consoles
. . . . . . . . . . . . . . . . . . . . .
55
Command Line Console Features on the CMC
55
Using a Serial, Telnet, or SSH Console
56
Using a Telnet Console With the CMC
56
. . . . . . . . . . . . . . . .
56
Enabling SSH on the CMC . . . . . . . . . . . . .
57
Changing the SSH Port . . . . . . . . . . . . . . .
57
Enabling the Front Panel to iKVM Connection
. . . . . . . . . . . . . . . . . .
58
Configuring Terminal Emulation Software
59
Configuring Linux Minicom . . . . . . . . . . . . .
59
Connecting to Servers or I/O Modules With the Connect Command
. . . . . . . . . . . . . . . . . .
61
Configuring the Managed Server BIOS for Serial Console Redirection
62
Configuring Windows for Serial
Console Redirection . . . . . . . . . . . . . . . .
63
Configuring Linux for Server Serial
Console Redirection During Boot
63
Configuring Linux for Server Serial
Console Redirection After Boot . . . . . . . . . .
65
Contents 5
6
4 Using the RACADM Command
Line Interface
. . . . . . . . . . . . . . . . . . . . .
69
Using a Serial, Telnet, or SSH Console
69
Logging in to the CMC . . . . . . . . . . . . . . .
70
Starting a Text Console . . . . . . . . . . . . . . .
70
. . . . . . . . . . . . . . . . . . . . . .
70
71
74
Enabling and Disabling the RACADM
Remote Capability . . . . . . . . . . . . . . . . . .
76
Using RACADM Remotely . . . . . . . . . . . . . .
76
RACADM Error Messages . . . . . . . . . . . . .
77
Using RACADM to Configure the CMC
78
Configuring CMC Network Properties
78
Setting Up Initial Access to the CMC
78
Viewing Current Network Settings
79
Configuring the Network LAN Settings . . . . . . .
80
Configuring the Network Security
Settings (IPv4 Only) . . . . . . . . . . . . . . . . .
86
Using RACADM to Configure Users
87
. . . . . . . . . . . . . . . . . .
87
. . . . . . . . . . . . . . . . .
88
Using RACADM to Configure Public Key
. . . . . . . . . . . . . . . . .
89
. . . . . . . . . . . . . . . . . .
89
Generating Public Keys for Windows . . . . . . . .
90
Generating Public Keys for Linux
91
91
Viewing the Public Keys . . . . . . . . . . . . . .
91
92
Contents
Deleting the Public Keys . . . . . . . . . . . . . .
92
Key Authentication . . . . . . . . . . . . . . . . .
92
Enabling a CMC User With Permissions
93
93
Configuring SNMP and E-mail Alerting
94
. . . . . . . . . . . . . . . . . . . . .
94
Creating a CMC Configuration File
95
. . . . . . . . . . . . . . . . . . . .
97
Modifying the CMC IP Address . . . . . . . . . . .
99
Using RACADM to Configure Properties on iDRAC
. . . . . . . . . . . . . . . . . . . . . . . . .
100
. . . . . . . . . . . . . . . . . . . . .
101
5 Using the CMC Web Interface
103
Accessing the CMC Web Interface
103
Logging In . . . . . . . . . . . . . . . . . . . . . .
104
Logging Out . . . . . . . . . . . . . . . . . . . . .
105
Configuring Basic CMC Settings
105
105
Setting the Date and Time on CMC
106
. . . . . . . . . . . . . . . . . . .
106
. . . . . . . . . . . . . . . . . . .
107
Chassis Group Features . . . . . . . . . . . . . .
107
Setting up a Chassis Group . . . . . . . . . . . . .
108
Removing a Member from the Leader . . . . . . .
109
Disbanding a Chassis Group . . . . . . . . . . . .
109
Contents 7
8 Contents
Disabling an Individual Member at the
. . . . . . . . . . . . . . . . .
110
110
Chassis Graphics . . . . . . . . . . . . . . . . .
110
Chassis Health . . . . . . . . . . . . . . . . . .
112
Selected Component Information
113
Monitoring System Health Status
119
Summaries . . . . . . . . . . . . . . . . . . . .
119
Viewing Power Budget Status . . . . . . . . . .
120
. . . . . . . . . . . . . . . . . . . .
120
All Servers . . . . . . . . . . . . . . . . . . . .
120
Editing Slot Names . . . . . . . . . . . . . . . .
124
Using Server’s Host Name as the
Slot Name . . . . . . . . . . . . . . . . . . . . .
125
Setting the First Boot Device for
Servers . . . . . . . . . . . . . . . . . . . . . .
125
Viewing the Health Status of an
. . . . . . . . . . . . . . . . .
127
Viewing the Health Status of IOMs
132
Viewing the Health Status of the Fans . . . . . .
133
135
Viewing the Health Status of the PSUs
137
Viewing Status of the Temperature
Sensors . . . . . . . . . . . . . . . . . . . . . .
139
. . . . . . . . . . . . . . . .
140
Viewing World Wide Name/Media Access
. . . . . . . . . . . . . . . .
141
Fabric Configuration . . . . . . . . . . . . . . .
141
WWN/MAC Addresses . . . . . . . . . . . . . .
142
Configuring CMC Network Properties
142
Setting Up Initial Access to CMC
142
Configuring the Network LAN Settings
143
Security Settings . . . . . . . . . . . . . . . . . .
151
. . . . . . . . . . . . . . . . . . . .
153
Adding and Configuring CMC Users
154
. . . . . . . . . . . . . . . . . . . . .
154
Adding and Managing Users . . . . . . . . . . . .
160
Configuring and Managing Microsoft Active
. . . . . . . . . . . . . . . . . .
163
Common Settings . . . . . . . . . . . . . . . . . .
163
167
167
Managing Active Directory Certificates
168
. . . . . . . . . . . . . . . . . . . . .
169
Configuring and Managing Generic Lightweight
Directory Access Protocol Services
169
171
172
Managing LDAP Security Certificates
172
Securing CMC Communications Using SSL and
. . . . . . . . . . . . . . . . . . . .
173
Secure Sockets Layer (SSL) . . . . . . . . . . . .
173
Certificate Signing Request (CSR) . . . . . . . . .
174
Accessing the SSL Main Menu . . . . . . . . . .
174
. . . . . . . . . . . . . . . . . .
175
Contents 9
10 Contents
Uploading a Server Certificate . . . . . . . . . .
178
Certificate . . . . . . . . . . . . . . . . . . . . .
178
179
. . . . . . . . . . . . . . . . . .
179
. . . . . . . . . . . . . . . . . .
180
188
189
Viewing the Current Firmware Versions . . . . .
189
Updating Firmware . . . . . . . . . . . . . . . .
190
Using CMC . . . . . . . . . . . . . . . . . . . .
195
. . . . . . . . . . . . . . . . . . . .
196
iDRAC QuickDeploy . . . . . . . . . . . . . . . .
196
iDRAC Network Settings . . . . . . . . . . . . .
200
. . . . . . . . . . . . . . . . . . . . .
202
Sign-On . . . . . . . . . . . . . . . . . . . . . .
203
. . . . . . . . . . . . . . . . . . . . . .
205
Viewing FlexAddress Status . . . . . . . . . . .
205
209
FlexAddress Configuration . . . . . . . . . . . .
209
. . . . . . . . . . . . . . . . . . .
210
. . . . . . . . . . . . . . . . . .
211
213
. . . . . . . . . . . . . . . . .
215
6 Using FlexAddress
. . . . . . . . . . . . . . . . .
217
. . . . . . . . . . . . . . . . .
218
Verifying FlexAddress Activation . . . . . . . . . .
220
. . . . . . . . . . . . . . . .
221
222
Configuring FlexAddress Using the CLI
222
Additional FlexAddress Configuration for Linux
. . . . . . . . . . . . . . . . . . . . . . .
223
Viewing FlexAddress Status Using the CLI
223
Configuring FlexAddress Using the GUI
224
Wake-On-LAN with FlexAddress . . . . . . . . . .
224
224
. . . . . . . . . . . . . . . . . . .
228
. . . . . . . . . . . . . . . . . .
231
7 Using FlexAddress Plus
235
235
FlexAddress vs FlexAddress Plus
236
. . . . . . . . . . . . . . . . . . .
237
8 Using the CMC Directory Service
241
Using CMC with Microsoft Active Directory
241
Active Directory Schema Extensions
241
Contents 11
12 Contents
Standard Schema Versus Extended
. . . . . . . . . . . . . . . . . . . . . .
241
Standard Schema Active Directory Overview
242
Active Directory to Access CMC
244
Configuring CMC With Standard Schema
Active Directory and Web Interface . . . . . . .
244
Configuring CMC With Standard Schema
Active Directory and RACADM . . . . . . . . . .
247
248
Active Directory Schema Extensions . . . . . . .
248
Overview of the RAC Schema Extensions . . . .
249
Active Directory Object Overview . . . . . . . .
249
Active Directory to Access Your CMC . . . . . .
254
Extending the Active Directory Schema
254
Installing the Dell Extension to the
. . . . . . . . . . . . . . . .
261
Adding CMC Users and Privileges to
Active Directory . . . . . . . . . . . . . . . . . .
262
Configuring CMC With Extended Schema
Active Directory and the Web Interface
264
Configuring CMC With Extended Schema
Active Directory and RACADM . . . . . . . . . .
267
Frequently Asked Questions . . . . . . . . . . .
269
272
272
273
Configuring Active Directory . . . . . . . . . . .
273
. . . . . . . . . . . . . . . . .
274
Uploading the Kerberos Keytab File
274
Enabling Single Sign-On . . . . . . . . . . . . .
275
. . . . . . . . . . . . . . . .
276
Logging into CMC Using Single Sign-On . . . . . .
277
Configuring Smart Card Two-Factor
. . . . . . . . . . . . . . . . . . . . . .
278
System Requirements . . . . . . . . . . . . . . . .
278
. . . . . . . . . . . . . . . .
278
279
Configuring CMC . . . . . . . . . . . . . . . . . .
279
Uploading the Kerberos Keytab File
279
Enabling Smart Card Authentication
280
Smart Card Login . . . . . . . . . . . . . . . . . .
280
Logging into CMC Using Smart Card . . . . . . . .
281
Troubleshooting the Smart Card Login . . . . . . .
281
282
Configuring the Generic LDAP Directory to Access CMC . . . . . . . . . . . . . . . . . . .
283
Configuring Generic LDAP Directory
Service Using CMC Web-Based Interface
284
Selecting Your LDAP Servers . . . . . . . . . . . .
286
287
Managing LDAP Security Certificates
287
Configuring Generic LDAP Directory
Service Using RACADM . . . . . . . . . . . . . .
288
Usage . . . . . . . . . . . . . . . . . . . . . . . .
288
Getting Help . . . . . . . . . . . . . . . . . . . . .
288
9 Power Management
289
. . . . . . . . . . . . . . . . . . . . . . . . .
289
AC Redundancy Mode . . . . . . . . . . . . . . .
289
Power Supply Redundancy Mode . . . . . . . . .
291
Contents 13
14 Contents
No Redundancy Mode . . . . . . . . . . . . . .
292
Power Budgeting for Hardware Modules . . . .
293
Server Slot Power Priority Settings . . . . . . . .
295
Dynamic Power Supply Engagement . . . . . . .
296
. . . . . . . . . . . . . . . . . .
298
AC Redundancy . . . . . . . . . . . . . . . . . .
298
298
. . . . . . . . . . . . . . . . . .
299
Budget Changes . . . . . . . . . . . . . . . . .
299
Power Supply and Redundancy Policy
Changes in System Event Log . . . . . . . . . . .
306
Power Health . . . . . . . . . . . . . . . . . . .
308
Configuring and Managing Power
308
Viewing the Health Status of the PSUs
308
Viewing Power Consumption Status
311
Viewing Power Budget Status . . . . . . . . . .
315
Configuring Power Budget and Redundancy . . . . . . . . . . . . . . . . .
320
Assigning Priority Levels to Servers . . . . . . .
324
Setting the Power Budget . . . . . . . . . . . .
325
Maintain Power Budget . . . . . . . . . . . . . .
327
Executing Power Control Operations on the Chassis . . . . . . . . . . . . . . . . . .
327
Executing Power Control Operations on an IOM
. . . . . . . . . . . . . . . . . . . . .
329
Executing Power Control Operations on a Server . . . . . . . . . . . . . . . . . . . .
330
Troubleshooting . . . . . . . . . . . . . . . . . .
332
10 Using the iKVM Module
333
. . . . . . . . . . . . . . . . . . . . . . . . .
333
iKVM User Interface . . . . . . . . . . . . . . . .
333
Security . . . . . . . . . . . . . . . . . . . . . . .
333
Scanning . . . . . . . . . . . . . . . . . . . . . .
333
Server Identification . . . . . . . . . . . . . . . .
334
Video . . . . . . . . . . . . . . . . . . . . . . . .
334
Plug and Play . . . . . . . . . . . . . . . . . . . .
334
FLASH Upgradable . . . . . . . . . . . . . . . . .
334
Physical Connection Interfaces
334
335
Tiering Through the ACI Connection . . . . . . . .
335
. . . . . . . . . . . . . . . . . . . . . . .
336
Navigation Basics . . . . . . . . . . . . . . . . .
336
Configuring OSCAR . . . . . . . . . . . . . . . . .
337
340
Peripherals Compatibility and Support
340
Viewing and Selecting Servers . . . . . . . . . . .
340
344
348
Broadcasting to Servers . . . . . . . . . . . . . .
350
351
Enabling or Disabling the Front Panel . . . . . . .
351
. . . . . . . . . . . . . . . . . . .
352
Viewing the iKVM Status and Properties
352
Updating the iKVM Firmware . . . . . . . . . . . .
354
. . . . . . . . . . . . . . . . . . . . .
355
Contents 15
16
11 I/O Fabric Management
361
. . . . . . . . . . . . . . . . . .
362
. . . . . . . . . . . . . . . . .
363
Configuration . . . . . . . . . . . . . . . . . . .
364
Invalid IOM-Mezzanine Card (MC)
Configuration . . . . . . . . . . . . . . . . . . .
364
Invalid IOM-IOM Configuration . . . . . . . . . .
364
364
. . . . . . . . . . . . . . . .
365
Viewing the Health Status of an
Individual IOM . . . . . . . . . . . . . . . . . .
368
Configuring Network Settings for an
. . . . . . . . . . . . . . . . . .
370
Troubleshooting IOM Network Settings
373
12 Troubleshooting and Recovery
375
. . . . . . . . . . . . . . . . . . . . . . . .
375
375
Gathering Configuration information and
Chassis Status and Logs . . . . . . . . . . . . .
375
Usage . . . . . . . . . . . . . . . . . . . . . . .
376
Supported Interfaces . . . . . . . . . . . . . . .
376
CLI RACDUMP . . . . . . . . . . . . . . . . . .
376
Remote RACDUMP . . . . . . . . . . . . . . . .
377
Remote RACDUMP Usage . . . . . . . . . . . .
377
Telnet RACDUMP . . . . . . . . . . . . . . . . .
378
Configuring LEDs to Identify Components on the Chassis . . . . . . . . . . . . . . . . . .
378
379
Contents
Configuring E-mail Alerts . . . . . . . . . . . . . .
385
First Steps to Troubleshooting a Remote System
388
Monitoring Power and Executing Power
Control Commands on the Chassis
389
Viewing Power Budget Status . . . . . . . . . . .
389
Executing a Power Control Operation . . . . . . .
389
. . . . . . . . . . . . . . . . .
389
392
. . . . . . . . . . . . . . . . . . . . . . .
397
. . . . . . . . . . . . . . . . .
398
Viewing the Hardware Log . . . . . . . . . . . . .
398
Viewing the CMC Log . . . . . . . . . . . . . . . .
400
401
. . . . . . . . . . . . . . . . . .
402
Troubleshooting Network Time Protocol
. . . . . . . . . . . . . . . . . . . . . . .
406
Interpreting LED Colors and Blinking Patterns
408
Troubleshooting a Non-responsive CMC
410
Observing the LEDs to Isolate the Problem
. . . . . . . . . . . . . . . . . . . . .
411
Obtain Recovery Information From the DB-9 Serial Port . . . . . . . . . . . . . . . .
411
Recovering the Firmware Image . . . . . . . . . .
412
Troubleshooting Network Problems
413
Resetting Forgotten Administrator Password
413
Contents 17
416
13 Diagnostics
. . . . . . . . . . . . . . . . . . . . . .
417
417
. . . . . . . . . . . . . . . . . . . . .
417
Main Menu . . . . . . . . . . . . . . . . . . . .
418
LCD Setup Menu . . . . . . . . . . . . . . . . .
419
Language Setup Screen . . . . . . . . . . . . .
419
Default Screen . . . . . . . . . . . . . . . . . .
419
Graphical Server Status Screen . . . . . . . . .
420
Graphical Module Status Screen . . . . . . . . .
421
Enclosure Menu Screen . . . . . . . . . . . . .
421
Module Status Screen . . . . . . . . . . . . . .
422
Enclosure Status Screen . . . . . . . . . . . . .
422
IP Summary Screen . . . . . . . . . . . . . . . .
422
. . . . . . . . . . . . . . . . . . . . . . .
423
423
426
. . . . . . . . . . . . . . . . . .
426
LCD Module and Server Status Information
433
Index
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
439
18 Contents
1
Overview
The Dell Chassis Management Controller (CMC) is a hot-pluggable systems management hardware and software solution designed to provide remote management capabilities and power control functions for Dell PowerEdge
M1000e chassis systems.
You can configure the CMC to send e-mail alerts or SNMP trap alerts for warnings or errors related to temperatures, hardware misconfigurations, power outages, and fan speeds.
The CMC, which has its own microprocessor and memory, is powered by the modular chassis into which it is plugged. To get started with the CMC, see
"Installing and Setting Up the CMC" on page 29.
What’s New For This Release
This release of CMC supports the following features:
• Multi-chassis management, which allows up to 8 other chassis to be visible from the lead chassis.
• Power Logging, which allows the user to collect power consumption measurements to a remote server.
• Save and restore configuration on a host.
• Improvement of SEL log.
• GPL/Open source compliant.
• Dell 8/4Gbps Fibre Channel Pass through IOM.
• Dell M8428-k IOM.
• Brocade BR1741M-k Dual Port Mezzanine Card.
• Server Performance Over Power Redundancy mode for power management.
Overview 19
20
CMC Management Features
The CMC provides the following management features:
• Redundant CMC Environment.
• Dynamic Domain Name System (DDNS) registration for IPv4 and IPv6.
• Remote system management and monitoring using SNMP, a Web interface, iKVM, Telnet or SSH connection.
• Support for Microsoft Active Directory authentication — Centralizes
CMC user IDs and passwords in Active Directory using the Standard
Schema or an Extended Schema.
• Monitoring — Provides access to system information and status of components.
• Access to system event logs — Provides access to the hardware log and
CMC log.
• Firmware updates for various components — Enables you to update the firmware for CMC, servers, iKVM, and I/O module infrastructure devices.
• Dell OpenManage software integration — Enables you to launch the CMC Web interface from Dell OpenManage Server Administrator or IT Assistant.
• CMC alert — Alerts you about potential managed node issues through an e-mail message or SNMP trap.
• Remote power management — Provides remote power management functions, such as shutdown and reset on any chassis component, from a management console.
• Power usage reporting.
• Secure Sockets Layer (SSL) encryption — Provides secure remote system management through the Web interface.
• Password-level security management — Prevents unauthorized access to a remote system.
• Role-based authority — Provides assignable permissions for different systems management tasks.
• Launch point for the Integrated Dell Remote Access Controller (iDRAC)
Web interface.
Overview
• Support for WS-Management.
• FlexAddress feature — Replaces the factory-assigned World Wide
Name/Media Access Control (WWN/MAC) IDs with chassis-assigned
WWN/MAC IDs for a particular slot, an optional upgrade. For more
information, see "Using FlexAddress" on page 217.
• Graphical display of chassis component status and health.
• Support for single and multi-slot servers.
• Update multiple iDRAC management consoles firmware at once.
• LCD iDRAC configuration wizard supports iDRAC network configuration
• iDRAC single sign-on.
• Network time protocol (NTP) support.
• Enhanced server summary, power reporting, and power control pages
• Forced CMC failover, and virtual reseat of servers.
• Multi-chassis management, allows up to 8 other chassis to be visible from the lead chassis.
Security Features
The CMC provides the following security features:
• User authentication through Active Directory (optional), or hardware-stored user IDs and passwords
• Role-based authority, which enables an administrator to configure specific privileges for each user
• User ID and password configuration through the Web interface
• Web interface supports 128-bit SSL 3.0 encryption and 40-bit SSL 3.0 encryption (for countries where 128-bit is not acceptable)
NOTE: Telnet does not support SSL encryption.
• Configurable IP ports (if applicable)
• Login failure limits per IP address, with login blocking from the IP address when the limit is exceeded
• Configurable session auto time out, and more than one simultaneous sessions
Overview 21
• Limited IP address range for clients connecting to the CMC
• Secure Shell (SSH), which uses an encrypted layer for higher security
• Single Sign-on, Two-Factor Authentication, and Public Key
Authentication
Chassis Overview
Figure 1-1 shows the facing edge of a CMC (inset) and the locations of the
CMC slots in the chassis.
Figure 1-1. Dell M1000e Chassis and CMC
2
1
1 GB Port
22 Overview
2 STK Port
Hardware Specifications
TCP/IP Ports
You must provide port information when opening firewalls for remote access to a CMC.
Table 1-1. CMC Server Listening Ports
Port Number
22*
23*
80*
161
443*
* Configurable port
Function
SSH
Telnet
HTTP
SNMP Agent
HTTPS
Table 1-2. CMC Client Port
Port Number
25
53
68
69
162
514*
636
3269
* Configurable port
Function
SMTP
DNS
DHCP-assigned IP address
TFTP
SNMP trap
Remote syslog
LDAPS
LDAPS for global catalog (GC)
Overview 23
24
Supported Remote Access Connections
Table 1-3. Supported Remote Access Connections
Connection
CMC Network
Interface ports
Serial port
Other connections
Features
• Two 10/100 GB ports; one for management and the other for chassis to chassis cable consolation
• 10Mbps/100Mbps/1Gbps Ethernet through CMC GbE port
• DHCP support
• SNMP traps and e-mail event notification
• GB port: Dedicated network interface for the CMC Web interface
• STK: Uplink port for chassis to chassis management network cable consolation
• Network interface for the iDRAC and I/O Modules (IOMs)
• Support for Telnet/SSH command console and RACADM CLI commands including system boot, reset, power-on, and shutdown commands
• Support for serial console and RACADM CLI commands including system boot, reset, power-on, and shutdown commands
• Support for binary interchange for applications specifically designed to communicate with a binary protocol to a particular type of IOM
• Serial port can be connected to the serial console of a server, or I/O module, using the connect (or racadm connect ) command
• Access to the Dell CMC Console through the Avocent Integrated
KVM Switch Module (iKVM)
Supported Platforms
The CMC supports modular systems designed for the M1000e platform.
For information about compatibility with the CMC, see the documentation for your device.
For the latest supported platforms, see the Dell Systems Software Support
Matrix located on the Dell Support website at support.dell.com/manuals .
Overview
Supported Web Browsers
The following Web Browsers are supported for CMC 3.1:
• Microsoft Internet Explorer 8.0 for Windows 7, Windows Vista, Windows
XP, and Windows Server 2003 family.
• Microsoft Internet Explorer 7.0 for Windows 7, Windows Vista, Windows
XP, and Windows Server 2003 family.
• Mozilla Firefox 1.5 (32-bit) – limited functionality.
For the latest information on supported Web browsers, see the Dell Systems
Software Support Matrix located on the Dell Support website at support.dell.com/manuals .
To view localized versions of the CMC Web interface:
1 Open the Windows Control Panel .
2 Double-click the Regional Options icon.
3 Select the required locale from the Your locale (location) drop-down menu.
Supported Management Console Applications
The CMC supports integration with Dell OpenManage IT Assistant.
For more information, see the IT Assistant documentation set available on the Dell Support Web site at support.dell.com/manuals .
WS-Management Support
Web Services for Management (WS-MAN) is a Simple Object Access
Protocol (SOAP)-based protocol used for systems management. WS-MAN provides a interoperable protocol for devices to share and exchange data across networks. CMC uses WS-MAN to convey Distributed Management
Task Force (DMTF) Common Information Model (CIM)-based management information. CIM information defines the semantics and information types that can be manipulated in a managed system.
The Dell-embedded server platform management interfaces are organized into profiles, where each profile defines the specific interfaces for a particular
Overview 25
26 management domain or area of functionality. Additionally, Dell has defined a number of model and profile extensions that provide interfaces for additional capabilities.
Access to WS-Management requires logging in using local user privileges with basic authentication over Secured Socket Layer (SSL) protocol at port 443. For information on setting user accounts, see the Session
Management database property section in the Command Line Reference
Guide for iDRAC6 and CMC.
The data available through WS-Management is a subset of data provided by the CMC instrumentation interface mapped to the following
DMTF profiles version 1.0.0:
• Allocation Capabilities Profile
• Base Metrics Profile
• Base Server Profile
• Computer System Profile
• Modular System Profile
• Physical Asset Profile
• Dell Power Allocation Profile
• Dell Power Supply Profile
• Dell Power Topology Profile
• Power State Management Profile
• Profile Registration Profile
• Record Log Profile
• Resource Allocation Profile
• Role Based Authorization Profile
• Sensors Profile
• Service Processor Profile
• Simple Identity Management Profile
• Dell Active Directory Client Profile
• Boot Control Profile
• Dell Simple NIC Profile
Overview
The CMC WS-MAN implementation uses SSL on port 443 for transport security, and supports basic authentication. For information on setting user accounts, see the cfgSessionManagement database property section in the
Command Line Reference Guide for iDRAC6 and CMC . Web services interfaces can be utilized by leveraging client infrastructure, such as Windows
WinRM and Powershell CLI, open source utilities like WSMANCLI, and application programming environments like Microsoft .NET.
For client connection using Microsoft WinRM, the minimum required version is 2.0. For more information, refer to the Microsoft article,
<http://support.microsoft.com/kb/968929>.
There are additional implementation guides, white papers, profile, and code samples available in the Dell Tech Center at www.delltechcenter.com
.
For more information, see:
• DTMF Web site: www.dmtf.org/standards/profiles/
• WS-MAN release notes or Read Me file.
• www.wbemsolutions.com/ws_management.html
• DMTF WS-Management Specifications: www.dmtf.org/standards/wbem/wsman
Other Documents You May Need
In addition to this guide, you can access the following guides available on the
Dell Support website at support.dell.com/manuals. On the Manuals page, click Software ï‚® Systems Management . Click on the appropriate product link on the right-side to access the documents:
• The CMC Online Help provides information about using the Web interface.
• The Chassis Management Controller (CMC) Secure Digital (SD) Card
Technical Specification provides minimum BIOS and firmware version, installation and usage information.
• The Integrated Dell Remote Access Controller 6 (iDRAC6) Enterprise for
Blade Servers User Guide provides information about installation, configuration and maintenance of the iDRAC on managed systems.
• The Dell OpenManage IT Assistant User’s Guide provides information about IT Assistant.
Overview 27
• Documentation specific to your third-party management console application.
• The Dell OpenManage Server Administrator’s User’s Guide provides information about installing and using Server Administrator.
• The Dell Update Packages User's Guide provides information about obtaining and using Dell Update Packages as part of your system update strategy.
The following system documents provide more information about the system in which CMC is installed:
• The safety instructions that came with your system provide important safety and regulatory information. For additional regulatory information, see the Regulatory Compliance home page at www.dell.com/regulatory_compliance . Warranty information may be included within this document or as a separate document.
• The Rack Installation Guide and Rack Installation Instructions included with your rack solution describe how to install your system into a rack.
• The Hardware Owner’s Manual provides information about system features and describes how to troubleshoot the system and install or replace system components.
• Systems management software documentation describes the features, requirements, installation, and basic operation of the software.
• Documentation for any components you purchased separately provides information to configure and install these options.
• Release notes or readme files may be included to provide last-minute updates to the system or documentation or advanced technical reference material intended for experienced users or technicians.
• For more information on IOM network settings, refer to the
Dell PowerConnect M6220 Switch Important Information document and the Dell PowerConnect 6220 Series Port Aggregator White Paper .
Updates are sometimes included with the system to describe changes to the system, software, and/or documentation. Always read the updates first because they often supersede information in other documents.
28 Overview
Installing and Setting Up the CMC
2
This section provides information about how to install your CMC hardware, establish access to the CMC, configure your management environment to use the CMC, and guides you through the next steps for configuring the CMC:
• Set up initial access to the CMC
• Access the CMC through a network
• Add and configure CMC users
• Update the CMC firmware
For more information about installing and setting up redundant CMC
environments see "Understanding the Redundant CMC Environment" on page 53."
Before You Begin
Before setting up your CMC environment, download the latest version of the
CMC firmware from the Dell Support website at support.dell.com
.
Also, ensure that you have the Dell Systems Management Tools and
Documentation DVD that was included with your system.
Installing the CMC Hardware
The CMC is pre-installed on your chassis and hence no installation is required. You can install a second CMC to run as a standby to the active
CMC. For more information about a standby CMC, see "Understanding the
Redundant CMC Environment" on page 53.
Installing and Setting Up the CMC 29
30
Checklist for Integration of a Chassis
The following steps enable you to setup the chassis accurately:
1 Your CMC and the management station where you use your browser must be on the same network, which is called the management network. Cable the CMC Ethernet port labelled GB to management network.
NOTE: Do not place a cable in the CMC Ethernet port labelled STK. For more
information to cable the STK port, see "Understanding the Redundant CMC
2 For rack chassis, install the IO modules in the chassis and cable them.
3 Insert the servers in the chassis.
4 Connect the chassis to the power source.
5 Push the Power button provided at the side of the chassis or, power on the
chassis from the CMC GUI after completing step 7.
NOTE: Do not power on the servers.
6 Using the LCD panel on the front of the system, provide the CMC with a static IP address or configure it for DHCP.
7 Connect to the CMC IP address through the web browser using the default username(root) and password(calvin).
8 Provide each iDRAC with an IP address in the CMC GUI and enable the
LAN and IPMI interface.
NOTE: iDRAC LAN interface on some servers are disabled by default
9 Provide each IO module with an IP address in the CMC GUI.
10 Connect to each iDRAC through the web browser and provide final configuration of iDRAC. Default username is root and password is calvin.
11 Connect to each IO module through the web browser and provide final configuration of the IO module.
12 Power on the servers and install the operating system.
Basic CMC Network Connection
For the highest degree of redundancy, connect each CMC to your management network. If a chassis has just one CMC, make one connection on the management network. If the chassis has a redundant CMC, make two connections to the management network.
Installing and Setting Up the CMC
Each CMC has two RJ-45 Ethernet ports, labeled GB (the uplink port) and
STK (the stacking or cable consolidation port). With basic cabling, you connect the GB port to the management network and leave the STK port unused.
CAUTION: Connecting the STK port to the management network can have unpredictable results. Cabling GB and STK to the same network (broadcast domain) can cause a broadcast storm.
Daisy-chain CMC Network Connection
If you have multiple chassis in a rack, you can reduce the number of connections to the management network by daisy-chaining up to four chassis together. If each of the four chassis contains a redundant CMC, by daisychaining you can reduce the number of management network connections required from eight to two. If each chassis has only one CMC, you can reduce the connections required from four to one.
When daisy-chaining chassis together, GB is the uplink port and STK is the stacking (cable consolidation) port. Connect the GB ports to the management network or to the STK port of the CMC in a chassis that is closer to the network. You must connect the STK port only to a GB port further from the chain or network.
Create separate chains for the CMCs in the active CMC slot and the second
CMC slot.
Figure 2-1 illustrates the arrangement of cables for four daisy-chained chassis,
each with active and standby CMCs.
Installing and Setting Up the CMC 31
Figure 2-1. Daisy-chained CMC Network Connection
1
3
2
32
1 management network
3 active CMC
Installing and Setting Up the CMC
2 standby CMC
Figure 2-2, Figure 2-3, and Figure 2-4 show examples of
incorrect cabling of the CMC.
Figure 2-2. Incorrect Cabling for CMC Network Connection - 2 CMCs
Figure 2-3. Incorrect Cabling for CMC Network Connection - Single CMC
Installing and Setting Up the CMC 33
Figure 2-4. Incorrect Cabling for CMC Network Connection - 2 CMCs
34
Follow these steps to daisy-chain up to four chassis:
1 Connect the GB port of the active CMC in the first chassis to the management network.
2 Connect the GB port of the active CMC in the second chassis to the STK port of the active CMC in the first chassis.
3 If you have a third chassis, connect the GB port of its active CMC to the
STK port of the active CMC in the second chassis.
4 If you have a fourth chassis, connect the GB port of its active CMC to the
STK port of the third chassis.
5 If you have redundant CMCs in the chassis, connect them using the same pattern.
CAUTION: The STK port on any CMC must never be connected to the management network. It can only be connected to the GB port on another chassis.
Connecting a STK port to the management network can disrupt the network and cause a loss of data. Cabling GB and STK to the same network (broadcast domain) can cause a broadcast storm.
NOTE: Never connect an active CMC to a standby CMC.
NOTE: Resetting a CMC whose STK port is chained to another CMC can disrupt the network for CMCs that appear later in the chain. The child CMCs may log messages indicating that the network link has been lost and they may fail over to their redundant CMCs.
To get started with the CMC, see "Installing Remote Access Software on a
Management Station" on page 35.
Installing and Setting Up the CMC
Installing Remote Access Software on a
Management Station
You can access the CMC from a management station using remote access software, such as the Telnet, Secure Shell (SSH), or serial console utilities provided on your operating system or using the Web interface.
To use remote RACADM from your management station, install remote
RACADM using the Dell Systems Management Tools and Documentation
DVD that is available with your system. This DVD includes the following
Dell OpenManage components:
• DVD root — Contains the Dell Systems Build and Update Utility.
• SYSMGMT — Contains the systems management software products including Dell OpenManage Server Administrator.
• Docs — Contains documentation for systems, systems management software products, peripherals, and RAID controllers.
• SERVICE — Contains the tools required to configure your system, and delivers the latest diagnostics and Dell-optimized drivers for your system.
For information about installing Dell OpenManage software components, see the Dell OpenManage Installation and Security User's Guide available on the
DVD or at support.dell.com/manuals . You can also download the latest version of the Dell DRAC Tools from the Dell Support website at support.dell.com
.
Installing RACADM on a Linux Management Station
1 Log on as root to the system running a supported Red Hat Enterprise
Linux or SUSE Linux Enterprise Server operating system where you want to install the managed system components.
2 Insert the Dell Systems Management Tools and Documentation DVD into the DVD drive.
Installing and Setting Up the CMC 35
36
3 To mount the DVD to a required location, use the mount command or a similar command.
NOTE: On the Red Hat Enterprise Linux 5 operating system, DVDs are auto-mounted with the
-noexec mount
option. This option does not allow you to run any executable from the DVD. You need to mount the DVD-ROM manually and then run the executables.
4 Navigate to the SYSMGMT/ManagementStation/linux/rac directory.
To install the RAC software, type the following command: rpm -ivh *.rpm
5 For help on the RACADM command, type racadm help after you run the previous commands. For more information about RACADM, see
"Using the RACADM Command Line Interface" on page 69.
NOTE: When using the RACADM remote capability, you must have write permission on the folders where you are using the RACADM subcommands involving file operations, for example: racadm getconfig -f <file name>
For more information on remote racadm, see "Accessing RACADM
Remotely" on page 74 and the subsequent sections.
Uninstalling RACADM From a Linux Management Station
1 Log on as root to the system where you want to uninstall the management station features.
2 Use the following rpm query command to determine which version of the
DRAC Tools is installed: rpm -qa | grep mgmtst-racadm
3 Verify the package version to be uninstalled and uninstall the feature by using the rpm -e `rpm -qa | grep mgmtst-racadm` command.
Configuring a Web Browser
You can configure and manage the CMC and the servers and modules installed in the chassis through a Web browser. See the Supported Browsers section in the Dell Systems Software Support Matrix on the Dell Support website at support.dell.com/manuals .
Installing and Setting Up the CMC
Your CMC and the management station where you use your browser must be on the same network, which is called the management network . Depending on your security requirements, the management network can be an isolated, highly secure network.
NOTE: Ensure that security measures on the management network, such as firewalls and proxy servers, do not prevent your Web browser from accessing the CMC.
Some browser features can interfere with connectivity or performance, especially if the management network does not have a route to the Internet. If your management station is running a Windows operating system, some
Internet Explorer settings can interfere with connectivity even though you use a command line interface to access the management network.
Proxy Server
To browse through a proxy server that does not have access to the management network, you can add the management network addresses to the browser’s exception list. This instructs the browser to bypass the proxy server while accessing the management network.
Internet Explorer
Follow these steps to edit the exception list in Internet Explorer:
1 Start Internet Explorer.
2 Click Tools ï‚® Internet Options ï‚® Connections .
3 In the Local Area Network (LAN) settings section, click LAN Settings.
4 In the Proxy server section, click Advanced.
5 In the Exceptions section, add the addresses for CMCs and iDRACs on the management network to the semicolon-separated list. You can use
DNS names and wildcards in your entries.
Mozilla FireFox
To edit the exception list in Mozilla Firefox version 3.0:
1 Start Mozilla Firefox.
2 Click Tools ï‚® Options (for Windows) or click Edit ï‚®ï€ Preferences
(for Linux) .
Installing and Setting Up the CMC 37
3 Click Advanced and then click the Network tab.
4 Click Settings .
5 Select the Manual Proxy Configuration.
6 In the No Proxy for field, type the addresses for CMCs and iDRACs on the management network to the comma-separated list. You can use DNS names and wildcards in your entries.
Microsoft Phishing Filter
If the Microsoft Phishing Filter is enabled in Internet Explorer 7 on your management system, and your CMC does not have Internet access, accessing the CMC may be delayed by a few seconds. This delay can happen if you are using the browser or another interface such as remote RACADM.
Follow these steps to disable the phishing filter:
1 Start Internet Explorer.
2 Click Tools ï‚® Phishing Filter , and then click Phishing Filter Settings .
3 Select the Disable Phishing Filter check box.
4 Click OK .
Certificate Revocation List (CRL) Fetching
If your CMC has no route to the Internet, disable the certificate revocation list
(CRL) fetching feature in Internet Explorer. This feature tests whether a server such as the CMC Web server uses a certificate that is on a list of revoked certificates retrieved from the Internet. If the Internet is inaccessible, this feature can cause delays of several seconds when you access the CMC using the browser or with a command line interface such as remote RACADM.
Follow these steps to disable CRL fetching:
1 Start Internet Explorer.
2 Click Tools ï‚® Internet Options , and then click Advanced .
3 Scroll to the Security section and uncheck Check for publisher’s certificate revocation .
4 Click OK .
38 Installing and Setting Up the CMC
Downloading Files From CMC With Internet Explorer
When you use Internet Explorer to download files from the CMC you may experience problems when the Do not save encrypted pages to disk option is not enabled.
Follow these steps to enable the Do not save encrypted pages to disk option:
1 Start Internet Explorer.
2 Click Tools ï‚® Internet Options , then click Advanced .
3 Scroll to the Security section and check Do not save encrypted pages to disk .
Allow Animations in Internet Explorer
When transferring files to and from the Web interface, a file transfer icon spins to show transfer activity. For Internet Explorer, this requires that the browser be configured to play animations, which is the default setting.
Follow these steps to configure Internet Explorer to play animations:
1 Start Internet Explorer.
2 Click Tools ï‚® Internet Options , then click Advanced .
3 Scroll to the Multimedia section and check Play animations in web pages .
Setting Up Initial Access to the CMC
To manage the CMC remotely, connect the CMC to your management network and then configure the CMC network settings.
NOTE: To manage the M1000e solution, it must be connected to your management network.
For information on how to configure the CMC network settings, see
"Configuring the CMC Network" on page 40. This initial configuration
assigns the TCP/IP networking parameters that enable access to the CMC.
The CMC and iDRAC on each server and the network management ports for all switch I/O Modules are connected to a common internal network in the
M1000e chassis. This allows the management network to be isolated from the server data network. It is important to separate this traffic for uninterrupted access to chassis management.
Installing and Setting Up the CMC 39
40
The CMC is connected to the management network. All external access to the CMC and iDRACs is accomplished through the CMC. Access to the managed servers, conversely, is accomplished through network connections to I/O modules (IOMs). This allows the application network to be isolated from the management network.
NOTE: It is recommended to isolate chassis management from the data network.
Dell cannot support or guarantee uptime of a chassis that is improperly integrated into your environment. Due to the potential of traffic on the data network, the management interfaces on the internal management network can be saturated by traffic intended for servers.This results in CMC and iDRAC communication delays.
These delays may cause unpredictable chassis behavior, such as CMC displaying iDRAC as offline even when it is up and running, which in turn causes other unwanted behavior. If physically isolating the management network is impractical, the other option is to separate CMC and iDRAC traffic to a separate VLAN. The CMC and individual iDRAC network interfaces can be configured to use a VLAN with the racadm setniccfg command. For more information, see the Dell Chassis
Management Controller Administrator Reference Guide .
If you have one chassis, connect the CMC and the standby CMC to the management network. If you have a redundant CMC, use another network cable and connect the GB CMC port to a second port of the management network.
If you have more than one chassis you can choose between the basic connection, where each CMC is connected to the management network, or a daisy-chained chassis connection, where the chassis are connected in series and only one CMC is connected to the management network. The basic connection type uses more ports on the management network and provides greater redundancy. The daisy-chain connection type uses fewer ports on the management network but introduces dependencies between CMCs, reducing the redundancy of the system.
For more information on daisy-chained connection, see "Daisy-chain CMC
Network Connection" on page 31."
NOTE: Failure to cable the CMC properly in a redundant configuration can cause loss of management and create broadcast storms.
Configuring the CMC Network
NOTE: Changing your CMC Network settings may disconnect your current network connection.
Installing and Setting Up the CMC
You can perform the initial network configuration of the CMC before or after the CMC has an IP address. If you configure the CMC’s initial network settings before you have an IP address, you can use either of the following interfaces:
• The LCD panel on the front of the chassis
• Dell CMC serial console
If you configure initial network settings after the CMC has an IP address, you can use any of the following interfaces:
• Command line interfaces (CLIs) such as a serial console, Telnet, SSH, or the Dell CMC Console through iKVM
• Remote RACADM
• The CMC Web interface
Configuring Networking Using the LCD Configuration Wizard
NOTE: The option to configure the CMC using the LCD Configuration Wizard is available only until the CMC is deployed or the default password is changed.
If the password is not changed, the LCD can continue to be used to reconfigure the CMC causing a possible security risk.
Installing and Setting Up the CMC 41
The LCD is located on the bottom left corner on the front of the chassis.
Figure 2-5 illustrates the LCD panel.
Figure 2-5. LCD Display
1
1
3
LCD screen scroll buttons (4)
2
4 selection ("check") button status indicator LED
The LCD screen displays menus, icons, pictures, and messages.
A status indicator LED on the LCD panel provides an indication of the overall health of the chassis and its components.
• Solid blue indicates good health.
4
2
3
42 Installing and Setting Up the CMC
• Blinking amber indicates that at least one component has a fault condition.
• Blinking blue is an ID signal, used to identify one chassis in a group of chassis.
Navigating in the LCD Screen
The right side of the LCD panel contains five buttons: four arrow buttons
(up, down, left, and right) and a center button.
• To move between screens , use the right (next) and left (previous) arrow buttons. At any time while using the Configuration Wizard, you can return to a previous screen.
• To scroll through options on a screen , use the down and up arrow buttons.
• To select and save an item on a screen and move to the next screen , use the center button.
For more information about using the LCD panel, see the LCD panel section in the Command Line Reference Guide for iDRAC6 and CMC .
Using the LCD Configuration Wizard
1 If you have not already done so, press the chassis power button to turn it on.
The LCD screen displays a series of initialization screens as it powers up.
When it is ready, the Language Setup screen displays.
2 Select your language using the arrow buttons, and then press the center button to select the Accept/Yes and press the center button again.
3 The Enclosure screen displays with the following question: Configure
Enclosure?
a b
Press the center button to continue to the CMC Network Settings screen. See step 4.
To exit the Configure Enclosure menu, select the NO icon and press the center button. See step 9.
Installing and Setting Up the CMC 43
4 Press the center button to continue to the CMC Network Settings screen.
5 Select your network speed (10Mbps, 100Mbps, Auto (1 Gbps)) using the down arrow button.
NOTE: The Network Speed setting must match your network configuration for effective network throughput. Setting the Network Speed lower than the speed of your network configuration increases bandwidth consumption and slows network communication. Determine whether your network supports the above network speeds and set it accordingly. If your network configuration does not match any of these values, Dell recommends that you use Auto
Negotiation (the Auto option) or refer to your network equipment manufacturer.
Press the center button to continue to the next CMC Network
Settings screen.
6 Select the duplex mode (half or full) that matches your network environment.
NOTE: The network speed and duplex mode settings are not available if Auto
Negotiation is set to On or 1000MB (1Gbps) is selected.
NOTE: If auto negotiation is turned on for one device but not the other, then the device using auto negotiation can determine the network speed of the other device, but not the duplex mode; in this case, duplex mode defaults to the half duplex setting during auto negotiation. Such a duplex mismatch results in a slow network connection.
Press the center button to continue to the next CMC Network
Settings screen.
7 Select the Internet Protocol (IPv4, IPv6, or both) that you want to use for the CMC.
Press the center button to continue to the next CMC Network
Settings screen.
44 Installing and Setting Up the CMC
8 Select the mode in which you want the CMC to obtain the
NIC IP addresses:
Dynamic Host
Configuration
Protocol
(DHCP)
Static
The CMC retrieves IP configuration (IP address, mask, and gateway) automatically from a DHCP server on your network. The CMC is assigned a unique IP address allotted over your network. If you have selected the DHCP option, press the center button. The Configure iDRAC?
screen
You manually enter the IP address, gateway, and subnet mask in the screens immediately following.
If you have selected the Static option, press the center button to continue to the next CMC Network Settings screen, then: a Set the Static IP Address by using the right or left arrow keys to move between positions, and the up and down arrow keys to select a number for each position.
When you have finished setting the Static IP Address , press the center button to continue.
b c
Set the subnet mask, and then press the center button.
Set the gateway, and then press the center button.
The Network Summary screen displays.
d
The Network Summary screen lists the Static IP
Address , Subnet Mask , and Gateway settings you entered. Review the settings for accuracy. To correct a setting, navigate to the left arrow button then press the center key to return to the screen for that setting.
After making a correction, press the center button.
When you have confirmed the accuracy of the settings you entered, press the center button. The Register DNS?
screen appears.
NOTE: If the Dynamic Host Configuration Protocol (DHCP) mode is selected for CMC IP configuration, then DNS registration is also enabled by default.
9 If you selected DHCP in the previous step, go to step 10.
To register your DNS server’s IP address, press the center button to proceed. If you have no DNS, press the right arrow key. The Register
DNS?
screen appears; go to step 10.
Installing and Setting Up the CMC 45
Set the DNS IP Address using the right or left arrow keys to move between positions, and the up and down arrow keys to select a number for each position. When you have finished setting the DNS IP address, press the center button to continue.
10 Indicate whether you want to configure iDRAC:
– No: Skip to step 13.
– Yes: Press the center button to proceed.
You can also configure iDRAC from the CMC GUI.
11 Select the Internet Protocol (IPv4, IPv6, or both) that you want to use for the servers.
46
Dynamic Host
Configuration
Protocol
(DHCP)
Static iDRAC retrieves IP configuration (IP address, mask, and gateway) automatically from a DHCP server on your network. The iDRAC is assigned a unique IP address allotted over your network.Press the center button.
You manually enter the IP address, gateway, and subnet mask in the screens immediately following.
If you have selected the Static option, press the center button to continue to the next iDRAC Network Settings screen, then: a b
Set the Static IP Address by using the right or left arrow keys to move between positions, and the up and down arrow keys to select a number for each position.
This address is the static IP of the iDRAC located in the first slot. The static IP address of each subsequent iDRAC is calculated as a slot number increment of this IP address. When you have finished setting the
Static IP Address , press the center button to continue.
Set the subnet mask, and then press the center button.
c Set the gateway, and then press the center button. a b
Select whether to Enable or Disable the IPMI LAN channel. Press the center button to continue.
On the iDRAC Configuration screen, to apply all iDRAC network settings to the installed servers, highlight the Accept/Yes icon and press the center button. To not apply the iDRAC network settings to
Installing and Setting Up the CMC
c the installed servers, highlight the No icon and press the center button and continue to step c.
On the next iDRAC Configuration screen, to apply all iDRAC network settings to newly installed servers, highlight the Accept/Yes icon and press the center button; when a new server is inserted into the chassis, the LCD prompts the user on whether to automatically deploy the server using the previously configured network settings/policies. To not apply the iDRAC network settings to newly installed servers, highlight the No icon and press the center button; when a new server is inserted into the chassis, the iDRAC network settings do not get configured.
12 On the Enclosure screen, to apply all enclosure settings highlight the
Accept/Yes icon and press the center button. To not apply the enclosure settings, highlight the No icon and press the center button.
13 On the IP Summary screen, review the IP addresses you provided to make sure the addresses are accurate. To correct a setting, navigate to the left arrow button and then press the center key to return to the screen for that setting. After making a correction, press the center button. If necessary, navigate to the right arrow button and then press the center key to return to the IP Summary screen.
When you have confirmed that the settings you entered are accurate, press the center button. The Configuration Wizard closes and returns you to the Main Menu screen.
NOTE: If you selected Yes/Accept, a Wait screen is displayed before the
IP Summary screen is displayed.
The CMC and iDRACs are now available on the network. You can access the CMC on the assigned IP address using the Web interface or CLIs such as a serial console, Telnet, and SSH.
NOTE: After you have completed network setup through the LCD Configuration
Wizard, the Wizard is no longer available.
Installing and Setting Up the CMC 47
48
Accessing the CMC Through a Network
After you have configured the CMC network settings, you can remotely access the CMC using any of the following interfaces:
• Web interface
• Telnet console
• SSH
• Remote RACADM
NOTE: Since telnet is not as secure as the other interfaces, it is disabled by default.
Enable Telnet using web, ssh, or remote RACADM.
Table 2-1. CMC Interfaces
Interface Description
Web interface
Remote RACADM command line interface
Provides remote access to the CMC from a management station using a command line interface (CLI). Remote RACADM uses the racadm -r option with the CMC’s IP address to execute commands on the CMC.
For more information on remote racadm, see "Accessing
RACADM Remotely" on page 74 and subsequent sections.
Telnet
Provides remote access to the CMC using a graphical user interface. The Web interface is built into the CMC firmware and is accessed through the NIC interface from a supported
Web browser on the management station.
For a list of supported Web browsers, see the Supported
Browsers section in the Dell System Software Support Matrix on the Dell Support website at support.dell.com/manuals .
Provides command line access to the CMC through the network.
The RACADM command line interface and the connect command, which is used to connect to the serial console of a server or IO module, are available from the CMC command line.
NOTE: Telnet is an insecure protocol that transmits all data— including passwords—in plain text. When transmitting sensitive information, use the SSH interface.
SSH Provides the same capabilities as Telnet using an encrypted transport layer for greater security.
Installing and Setting Up the CMC
NOTE: The CMC default user name is root and the default password is calvin.
You can access the CMC and iDRAC Web interfaces through the CMC
Network Interface using a supported Web browser; you can also launch them from the Dell Server Administrator or Dell OpenManage IT Assistant.
For a list of supported Web browsers, see the Supported Browsers section in the Dell Systems Software Support Matrix on the Dell Support website at support.dell.com/manuals . To access the CMC using a supported Web
browser, see "Accessing the CMC Web Interface" on page 103. For
information on Dell OpenManage IT Assistant, see "Installing Remote Access
Software on a Management Station" on page 35.
To access the CMC interface using Dell Server Administrator, launch Server
Administrator on your management station. From the system tree on the left pane of the Server Administrator home page, click System ï‚® Main System
Chassis ï‚® Remote Access Controller . For more information, see your Dell
Server Administrator User’s Guide .
To access the CMC command line using Telnet or SSH, see "Configuring
CMC to Use Command Line Consoles" on page 55.
For information about using RACADM, see "Using the RACADM Command
For information about using the connect , or racadm connect , command
to connect to servers and IO modules, see "Connecting to Servers or I/O
Modules With the Connect Command" on page 61.
Installing or Updating the CMC Firmware
Downloading the CMC Firmware
Before beginning the firmware update, download the latest firmware version from the Dell Support website at support.dell.com
, and save it to your local system.
The following software components are included with your CMC firmware package:
• Compiled CMC firmware code and data
• Web interface, JPEG, and other user interface data files
• Default configuration files
Installing and Setting Up the CMC 49
NOTE: During updates of CMC firmware, it is normal for some or all of the fan units in the chassis to spin at 100%.
NOTE: The firmware update, by default, retains the current CMC settings. During the update process, you have the option to reset the CMC configuration settings back to the factory default settings.
NOTE: If you have redundant CMCs installed in the chassis, it is important to update both to the same firmware version. If the CMCs have different firmware and a failover occurs, unexpected results may occur.
You can use the RACADM getsysinfo command (see the getsysinfo command section in the Command Line Reference Guide for iDRAC6 and
CMC ) or the Chassis Summary
page (see "Viewing the Current Firmware
Versions" on page 189) to view the current firmware versions for the CMCs
installed in your chassis.
If you have a standby CMC, it is recommended that you update both CMCs at the same time with a single operation. When the standby CMC has been updated, swap the CMCs’ roles so that the newly updated CMC becomes the active CMC and the CMC with the older firmware becomes the standby.
(See the cmcchangeover command section in the Command Line Reference
Guide for iDRAC6 and CMC for help in swapping roles.) This allows you to verify that the update has succeeded and that the new firmware is working properly, before you update the firmware in the second CMC. When both
CMCs are updated, you can use the cmcchangeover command to restore the
CMCs to their previous roles. CMC Firmware revision 2.x updates both the primary CMC and the redundant CMC without using the cmcchangeover command.
Updating CMC Firmware Using the Web Interface
For instructions on using the Web interface to update CMC firmware, see
"Updating the CMC Firmware" on page 190.
Updating the CMC Firmware Using RACADM
For instructions on using the RACADM fwupdate subcommand to update
CMC firmware, see the fwupdate command section in the Command Line
Reference Guide for iDRAC6 and CMC .
50 Installing and Setting Up the CMC
Configuring CMC Properties
You can configure CMC properties such as power budgeting, network settings, users, and SNMP and e-mail alerts using the Web interface or RACADM.
For more information about using the Web interface, see "Accessing the
CMC Web Interface" on page 103. For more information about using
RACADM, see "Using the RACADM Command Line Interface" on page 69.
CAUTION: Using more than one CMC configuration tool at the same time may generate unexpected results.
Configuring Power Budgeting
The CMC offers a power budgeting service that allows you to configure power budget, redundancy, and dynamic power for the chassis.
The power management service enables optimization of power consumption and re-allocation of power to different modules based on demand.
For more information about CMC power management, see "Power
For instructions on configuring power budgeting and other power settings
using the Web interface, see "Configuring Power Budgeting" on page 188.
Configuring CMC Network Settings
NOTE: Changing your CMC network settings may disconnect your current network connection.
You can configure the CMC network settings using one of the following tools:
• RACADM — For more information, see "Configuring Multiple CMCs in
NOTE:
If you are deploying the CMC in a Linux environment, see "Installing
RACADM on a Linux Management Station" on page 35.
• Web interface — For more information, see "Configuring CMC Network
Installing and Setting Up the CMC 51
Adding and Configuring Users
You can add and configure CMC users using either RACADM or the
CMC Web interface. You can also utilize Microsoft Active Directory to manage users.
For instructions on adding and configuring public key users for the
CMC using RACADM, see "Using RACADM to Configure Public Key
Authentication over SSH" on page 89. For instructions on adding and
configuring users using the Web interface, see "Adding and Configuring
For instructions on using Active Directory with your CMC, see "Using the
CMC Directory Service" on page 241.
Adding SNMP and E-mail Alerts
You can configure the CMC to generate SNMP or e-mail alerts when certain
chassis events occur. For more information, see "Configuring SNMP Alerts"
on page 379 and "Configuring E-mail Alerts" on page 385.
Configuring Remote Syslog
The remote syslog feature is activated and configured through either the
CMC GUI or the racadm command. Configuration options include the syslog server name (or IP address) and the UDP port that CMC uses when forwarding the log entries. You can specify up to 3 distinct syslog server destinations in the configuration. Remote syslog is an additional log target for the CMC. After you configure the remote syslog, each new log entry generated by CMC is forwarded to the destination(s).
NOTE: Since the network transport for the forwarded log entries is UDP, there is no guaranteed delivery of log entries, nor is there any feedback to CMC whether the log entries were received successfully.
To configure CMC services:
1 Log in to the CMC Web interface.
2 Click the Network tab.
3 Click the Services subtab. The Services page appears.
For more information on configuring the remote syslog, see Table 5-56.
52 Installing and Setting Up the CMC
Understanding the Redundant CMC Environment
You can install a standby CMC that takes over if your active CMC fails. Your redundant CMC may be pre-installed or can be added at a later date. It is important that the CMC network is properly cabled to ensure full redundancy or best performance.
Failovers can occur when you:
• Run the RACADM cmcchangeover command. (See the cmcchangeover command section in the Command Line Reference Guide for iDRAC6 and
CMC.
• Run the RACADM racreset command on the active CMC. (See the racreset command section in the Command Line Reference Guide for iDRAC6 and CMC .
• Reset the active CMC from Web interface. (See the Reset CMC option for Power Control Operations
that is described in "Executing Power
Control Operations on the Chassis" on page 327.)
• Remove the network cable from the active CMC
• Remove the active CMC from the chassis
• Initiate a CMC firmware flash on the active CMC
• Have an active CMC that is no longer functional
NOTE: In the event of a CMC failover, all iDRAC connections and all active CMC sessions are lost. Users with lost sessions must reconnect to the new active CMC.
About the Standby CMC
The standby CMC is identical to and is maintained as a mirror of the active
CMC. The active and standby CMCs must both be installed with the same firmware revision. If the firmware revisions differ, the system reports as redundancy degraded.
The standby CMC assumes the same settings and properties of the active CMC. You must maintain the same firmware version on both CMCs, but you do not need to duplicate configuration settings on the standby CMC.
NOTE: For information about installing a standby CMC, see the Hardware Owner’s
Manual . For instructions on installing the CMC firmware on your standby CMC,
follow the instructions in "Installing or Updating the CMC Firmware" on page 49.
Installing and Setting Up the CMC 53
Active CMC Election Process
There is no difference between the two CMC slots; that is, slot does not dictate precedence. Instead, the CMC that is installed or booted first assumes the role of the active CMC. If AC power is applied with two CMCs installed, the CMC installed in CMC chassis slot 1 (the left) normally assumes the active role. The active CMC is indicated by the blue LED.
If two CMCs are inserted into a chassis that is already powered on, automatic active/standby negotiation can take up to two minutes.
Normal chassis operation resumes when the negotiation is complete.
Obtaining Health Status of Redundant CMC
You can view the health status of the standby CMC in the Web interface. For more information about accessing CMC health status in the Web interface,
see "Viewing Chassis and Component Summaries" on page 119.
54 Installing and Setting Up the CMC
Configuring CMC to Use Command
Line Consoles
3
This section provides information about the CMC command line console
(or serial/Telnet/Secure Shell console) features, and explains how to set up your system so you can perform systems management actions through the console. For information on using the RACADM commands in CMC
through the command line console, see "Using the RACADM Command
Command Line Console Features on the CMC
The CMC supports the following serial, Telnet and SSH console features:
• One serial client connection and up to four simultaneous Telnet client connections.
• Up to four simultaneous Secure Shell (SSH) client connections
• RACADM command support.
• Built-in connect command connecting to the serial console of servers and
I/O modules; also available as racadm connect.
• Command Line editing and history.
• Session timeout control on all console interfaces.
Configuring CMC to Use Command Line Consoles 55
56
Using a Serial, Telnet, or SSH Console
When you connect to the CMC command line, you can enter these commands:
Table 3-1. CMC Command Line Commands
Command racadm connect exit, logout, and quit
Description
RACADM commands begin with the keyword racadm and are followed by a subcommand, such as getconfig , serveraction , or getsensorinfo
. See "Using the RACADM Command Line Interface" on page 69 for details on using RACADM.
Connects to the serial console of a server or I/O module.
See "Connecting to Servers or I/O Modules With the Connect
Command" on page 61 for help using the
connect command.
NOTE: The racadm connect command can also be used.
These commands all perform the same action: they end the current session and return to a login prompt.
Using a Telnet Console With the CMC
Up to four Telnet client systems and four SSH clients may connect at any given time.
If your management station is running Windows XP or Windows 2003, you may experience an issue with the characters in a CMC Telnet session. This issue may occur as a frozen login where the return key does not respond and the password prompt does not appear.
To fix this issue, download hotfix 824810 from the Microsoft Support website at support.microsoft.com
. See Microsoft Knowledge Base article 824810 for more information.
Using SSH With the CMC
SSH is a command line session that includes the same capabilities as a Telnet session, but with session negotiation and encryption to improve security.
The CMC supports SSH version 2 with password authentication. SSH is enabled on the CMC by default.
NOTE: The CMC does not support SSH version 1.
Configuring CMC to Use Command Line Consoles
When an error occurs during the login procedure, the SSH client issues an error message. The message text is dependent on the client and is not controlled by the CMC. Review the RACLog messages to determine the cause of the failure.
NOTE: OpenSSH should be run from a VT100 or ANSI terminal emulator on
Windows. You can also run OpenSSH using Putty.exe. Running OpenSSH keys do not respond and no graphics are displayed). For Linux, run SSH Client
Services to connect to CMC with any shell.
at the Windows command prompt does not provide full functionality (that is, some
Four simultaneous SSH sessions are supported at any given time. The session timeout is controlled by the cfgSsnMgtSshIdleTimeout property
(see the database property chapter of the Command Line Reference Guide for iDRAC6 and CMC or from the Services Management page in the Web
interface (see "Configuring Services" on page 180.)
CMC also supports the Public Key Authentication (PKA) over SSH.
This authentication method improves SSH scripting automation by removing the need to embed or prompt for user ID/password. For more information,
see "Using RACADM to Configure Public Key Authentication over SSH" on page 89.
Enabling SSH on the CMC
SSH is enabled by default. If SSH is disabled, then you can enable it using any other supported interface.
For instructions on enabling SSH connections on the CMC using RACADM, see the config command section and the cfgSerial database property section in the Command Line Reference Guide for iDRAC6 and CMC . For instructions on enabling SSH connections on the CMC using the Web
interface, see "Configuring Services" on page 180.
Changing the SSH Port
To change the SSH port, run the following command: racadm config -g cfgRacTuning -o cfgRacTuneSshPort
<port number>
For more information about cfgSerialSshEnable and cfgRacTuneSshPort properties, see the database property chapter of the
Command Line Reference Guide for iDRAC6 and CMC .
Configuring CMC to Use Command Line Consoles 57
The CMC SSH implementation supports multiple cryptography schemes,
Table 3-2. Cryptography Schemes
Scheme Type Scheme
Asymmetric Cryptography Diffie-Hellman DSA/DSS
512–1024 (random) bits per NIST specification
Symmetric Cryptography • AES256-CBC
• RIJNDAEL256-CBC
• AES192-CBC
• RIJNDAEL192-CBC
• AES128-CBC
• RIJNDAEL128-CBC
• BLOWFISH-128-CBC
• 3DES-192-CBC
• ARCFOUR-128
Message Integrity
Authentication
• HMAC-SHA1-160
• HMAC-SHA1-96
• HMAC-MD5-128
• HMAC-MD5-96
Password
Enabling the Front Panel to iKVM Connection
For information and instructions on using the iKVM front panel ports, see
"Enabling or Disabling the Front Panel" on page 351.
58 Configuring CMC to Use Command Line Consoles
Configuring Terminal Emulation Software
Your CMC supports a serial text console from a management station running one of the following types of terminal emulation software:
• Linux Minicom.
• Hilgraeve’s HyperTerminal Private Edition (version 6.3).
Perform the steps in the following subsections to configure the required type of terminal software.
Configuring Linux Minicom
Minicom is a serial port access utility for Linux. The following steps are valid for configuring Minicom version 2.0. Other Minicom versions may differ
slightly but require the same basic settings. Use the information in "Required
Minicom Settings" on page 60 to configure other versions of Minicom.
Configuring Minicom Version 2.0
NOTE: For best results, set the cfgSerialConsoleColumns property to match the number of columns. Be aware that the prompt consumes two characters.
For example, for an 80-column terminal window: racadm config –g cfgSerial –o cfgSerialConsoleColumns 80 .
1 If you do not have a Minicom configuration file, go to the next step.
If you have a Minicom configuration file, type minicom <Minicom config file name>
2 At the Linux command prompt, type minicom -s .
3 Select Serial Port Setup and press <Enter>.
4 Press <a>, and then select the appropriate serial device (for example,
/dev/ttyS0 ).
5 Press <e>, and then set the Bps/Par/Bits option to 115200 8N1 .
6 Press <f>, and then set Hardware Flow Control to Yes and set Software
Flow Control to No .
To exit the Serial Port Setup menu, press <Enter>.
7 Select Modem and Dialing and press <Enter>.
Configuring CMC to Use Command Line Consoles 59
8 In the Modem Dialing and Parameter Setup menu, press <Backspace> to clear the init , reset , connect , and hangup settings so that they are blank, and then press <Enter> to save each blank value.
9 When all specified fields are clear, press <Enter> to exit the Modem
Dialing and Parameter Setup menu.
10 Select Save setup as config_name and press <Enter>.
11 Select Exit From Minicom and press <Enter>.
12 At the command shell prompt, type minicom <Minicom config file name> .
13 Press <Ctrl+a>, <x>, <Enter> to exit Minicom.
Ensure that the Minicom window displays a login prompt. When the login prompt appears, your connection is successful. You are now ready to login and access the CMC command line interface.
Required Minicom Settings
Use Table 3-3 to configure any version of Minicom.
Table 3-3. Minicom Settings
Setting Description
Bps/Par/Bits
Hardware flow control
Software flow control
Terminal emulation
Modem dialing and parameter settings
Required Setting
115200 8N1
Yes
No
ANSI
Clear the init , reset , connect , and hangup settings so that they are blank
60 Configuring CMC to Use Command Line Consoles
Connecting to Servers or I/O Modules With the
Connect Command
The CMC can establish a connection to redirect the serial console of server or
I/O modules. For servers, serial console redirection can be accomplished in several ways:
• Using the CMC command line and the connect , or racadm connect command. For more information about connect , see the racadm connect command in the Command Line Reference Guide for iDRAC6 and CMC .
• Using the iDRAC Web interface serial console redirection feature.
• Using the iDRAC Serial Over LAN (SOL) functionality.
While in a serial/Telnet/SSH console, the CMC supports the connect command to establish a serial connection to server or IOM modules.
The server serial console contains both the BIOS boot and setup screens, as well as the operating system serial console. For I/O modules, the switch serial console is available.
CAUTION: When executed from the CMC serial console, the connect -b option stays connected until the CMC resets. This connection is a potential security risk.
NOTE: The connect command provides the –b (binary) option. The –b option passes raw binary data, and cfgSerialConsoleQuitKey is not used. Additionally, when connecting to a server using the CMC serial console, transitions in the
DTR signal (for example, if the serial cable is removed to connect a debugger) do not cause a logout.
NOTE: If an IOM does not support console redirection, the connect command will display an empty console. In that case, to return to the CMC console, type the Escape sequence. The default console escape sequence is <Ctrl>\.
There are up to six IOMs on the managed system. To connect to an IOM: connect switchn where n is an IOM label a1, a2, b1, b2, c1, and c2.
IOMs are labeled A1, A2, B1, B2, C1, and C2. (See Figure 11-1 for an
illustration of the placement of IOMs in the chassis.) When you reference the
IOMs in the connect command, the IOMs are mapped to switches as shown
Configuring CMC to Use Command Line Consoles 61
62
Table 3-4. Mapping I/O Modules to Switches
I/O Module Label
A1
A2
B1
B2
C1
C2
Switch switch-a1 switch-a2 switch-b1 switch-b2 switch-c1 switch-c2
NOTE: There can only be one IOM connection per chassis at a time.
NOTE: You cannot connect to pass-throughs from the serial console.
To connect to a managed server serial console, use the command connect server-n , where -n is the slot number of the server; you can also use the racadm connect server-n command. When you connect to a server using the b option, binary communication is assumed and the escape character is disabled. If the iDRAC is not available, you see a No route to host error message.
The connect server-n command enables the user to access the server's serial port. After this connection is established, the user can see the server's console redirection through CMC's serial port that includes both the BIOS serial console and the operating system serial console.
NOTE: To see the BIOS boot screens, serial redirection has to be enabled in the servers’ BIOS Setup. Also, you must set the terminal emulator window to 80x25.
Otherwise, the screen is garbled.
NOTE: Not all keys work in the BIOS setup screens, so provide appropriate escape sequences for CTRL+ALT+DEL, and other escape sequences. The initial redirection screen displays the necessary escape sequences.
Configuring the Managed Server BIOS for Serial Console Redirection
It is necessary to connect to the managed server using the iKVM
(see "Managing Servers With iKVM" on page 340), or establish a Remote
Console session from the iDRAC web GUI (see the iDRAC User’s Guide on support.dell.com/manuals ).
Configuring CMC to Use Command Line Consoles
Serial communication in the BIOS is OFF by default. To redirect host text console data to Serial over LAN, you must enable console redirection through COM1. To change the BIOS setting:
1 Boot the managed server.
2 Press <F2> to enter the BIOS setup utility during POST.
3 Scroll down to Serial Communication and press <Enter>. In the pop-up dialog box, the serial communication list displays these options:
• off
• on without console redirection
• on with console redirection via COM1
Use the arrow keys to navigate between these options.
4 Ensure that On with console redirection via COM1 is enabled.
5 Enable Redirection After Boot (default value is disabled ). This option enables BIOS console redirection across subsequent reboots.
6 Save the changes and exit.
7 The managed server reboots.
Configuring Windows for Serial Console Redirection
There is no configuration necessary for servers running the Microsoft
Windows Server versions, starting with Windows Server 2003. Windows receives information from the BIOS, and enable the Special Administration
Console (SAC) console one COM1.
Configuring Linux for Server Serial Console Redirection During Boot
The following steps are specific to the Linux GRand Unified Bootloader
(GRUB). Similar changes are necessary for using a different boot loader.
NOTE: When you configure the client VT100 emulation window, set the window or application that is displaying the redirected console to 25 rows x 80 columns to ensure proper text display; otherwise, some text screens may be garbled.
Edit the /etc/grub.conf file as follows:
1 Locate the general setting sections in the file and add the following two new lines:
Configuring CMC to Use Command Line Consoles 63
serial --unit=1 --speed=57600 terminal --timeout=10 serial
2 Append two options to the kernel line: kernel............. console=ttyS1,57600
3 If the /etc/grub.conf contains a splashimage directive, comment it out.
The following example shows the changes described in this procedure.
# grub.conf generated by anaconda
#
# Note that you do not have to rerun grub after making changes
# to this file
# NOTICE: You do not have a /boot partition.
This means that
# all kernel and initrd paths are relative to
/, e.g.
#
#
/dev/sdal root (hd0,0) kernel /boot/vmlinuz-version ro root=
#
# initrd /boot/initrd-version.img
#boot=/dev/sda default=0 timeout=10
#splashimage=(hd0,2)/grub/splash.xpm.gz
serial --unit=1 --speed=57600 terminal --timeout=10 serial title Red Hat Linux Advanced Server (2.4.9-e.3smp) root (hd0,0) kernel /boot/vmlinuz-2.4.9-e.3smp ro root=
/dev/sda1 hda=ide-scsi console=ttyS0 console= ttyS1,57600 initrd /boot/initrd-2.4.9-e.3smp.img
title Red Hat Linux Advanced Server-up (2.4.9-e.3)
64 Configuring CMC to Use Command Line Consoles
root (hd0,00) kernel /boot/vmlinuz-2.4.9-e.3 ro root=/dev/sda1 initrd /boot/initrd-2.4.9-e.3.img
When you edit the /etc/grub.conf
file, follow these guidelines:
• Disable GRUB's graphical interface and use the text-based interface; otherwise, the GRUB screen is not displayed in console redirection. To disable the graphical interface, comment out the line starting with splashimage .
• To start multiple GRUB options to start console sessions through the serial connection, add the following line to all options: console=ttyS1,57600
The example shows console=ttyS1,57600 added to only the first option.
Configuring Linux for Server Serial Console Redirection After Boot
Edit the file /etc/inittab , as follows:
• Add a new line to configure agetty on the COM2 serial port: co:2345:respawn:/sbin/agetty -h -L 57600 ttyS1 ansi
The following example shows the file with the new line.
#
#
#
# inittab This file describes how the INIT process should set up the system in a certain run-level.
#
#
#
# Author: Miquel van Smoorenburg
Modified for RHS Linux by Marc Ewing and
Donnie Barnes
#
#
#
#
#
# Default runlevel. The runlevels used by RHS are:
0 - halt (Do NOT set initdefault to this)
1 - Single user mode
2 - Multiuser, without NFS (The same as 3, if you do not have networking)
Configuring CMC to Use Command Line Consoles 65
#
#
#
#
3 - Full multiuser mode
4 - unused
5 - X11
6 - reboot (Do NOT set initdefault to this)
# id:3:initdefault:
# System initialization.
si::sysinit:/etc/rc.d/rc.sysinit
l0:0:wait:/etc/rc.d/rc 0 l1:1:wait:/etc/rc.d/rc 1 l2:2:wait:/etc/rc.d/rc 2 l3:3:wait:/etc/rc.d/rc 3 l4:4:wait:/etc/rc.d/rc 4 l5:5:wait:/etc/rc.d/rc 5 l6:6:wait:/etc/rc.d/rc 6
# Things to run in every runlevel.
ud::once:/sbin/update
# Trap CTRL-ALT-DELETE ca::ctrlaltdel:/sbin/shutdown -t3 -r now
# When our UPS tells us power has failed, assume we have a few
# minutes of power left. Schedule a shutdown for 2 minutes from now.
# This does, of course, assume you have power installed and your
# UPS is connected and working correctly. pf::powerfail:/sbin/shutdown -f -h +2 "Power Failure;
System Shutting Down"
# If power was restored before the shutdown kicked in, cancel it.
pr:12345:powerokwait:/sbin/shutdown -c "Power
Restored; Shutdown Cancelled"
66 Configuring CMC to Use Command Line Consoles
# Run gettys in standard runlevels co:2345:respawn:/sbin/agetty -h -L 57600 ttyS1 ansi
1:2345:respawn:/sbin/mingetty tty1
2:2345:respawn:/sbin/mingetty tty2
3:2345:respawn:/sbin/mingetty tty3
4:2345:respawn:/sbin/mingetty tty4
5:2345:respawn:/sbin/mingetty tty5
6:2345:respawn:/sbin/mingetty tty6
# Run xdm in runlevel 5
# xdm is now a separate service x:5:respawn:/etc/X11/prefdm -nodaemon
Edit the file /etc/securetty , as follows:
• Add a new line, with the name of the serial tty for COM2: ttyS1
The following example shows a sample file with the new line.
vc/1 vc/2 vc/3 vc/4 vc/5 vc/6 vc/7 vc/8 vc/9 vc/10 vc/11 tty1 tty2 tty3 tty4 tty5 tty6 tty7 tty8 tty9
Configuring CMC to Use Command Line Consoles 67
tty10 tty11 ttyS1
68 Configuring CMC to Use Command Line Consoles
4
Using the RACADM Command
Line Interface
RACADM provides a set of commands that allow you to configure and manage the CMC through a text-based interface. RACADM can be accessed using a Telnet/SSH or serial connection, using the Dell CMC console on the iKVM, or remotely using the RACADM command line interface installed on a management station.
The RACADM interface is classified as follows :
NOTE: Remote RACADM is included on the Dell Systems Management Tools and
Documentation DVD and is installed on a management station.
• Remote RACADM — Allows you to run RACADM commands on a management station with the -r option and the DNS name or IP address of the CMC.
• Firmware RACADM — Allows you to log in to the CMC using Telnet,
SSH, a serial connection, or the iKVM. With Firmware RACADM, you run the RACADM implementation that is part of the CMC firmware.
You can use remote RACADM commands in scripts to configure multiple
CMCs. The CMC does not have support for scripting, so you cannot run the scripts directly on the CMC. For more information about configuring
multiple CMCs, see "Configuring Multiple CMCs in Multiple Chassis" on page 94.
Using a Serial, Telnet, or SSH Console
You can log in to the CMC through a serial or Telnet/SSH connection, or through Dell CMC console on iKVM. To configure the CMC for serial or
remote access, see "Configuring CMC to Use Command Line Consoles" on
page 55. Commonly used subcommand options are listed in Table 4-2. A
complete list of RACADM subcommands is listed in the RACADM
Subcommands chapter of the Command Line Reference Guide for iDRAC6 and CMC .
Using the RACADM Command Line Interface 69
Logging in to the CMC
After you have configured your management station terminal emulator software and managed node BIOS, perform the following steps to log in to the CMC:
1 Connect to the CMC using your management station terminal emulation software.
2 Type your CMC user name and password, and then press <Enter>.
You are logged in to the CMC.
Starting a Text Console
You can log in to the CMC using Telnet or SSH through a network, serial port, or a Dell CMC console through the iKVM. Open a Telnet or
SSH session, connect and log in to the CMC.
For information about connecting to the CMC through iKVM, see "Using the iKVM Module" on page 333.
Using RACADM
RACADM subcommands can be run remotely from the serial, Telnet, or SSH console command prompt or through a normal command prompt.
Use RACADM subcommands to configure CMC properties and perform remote management tasks. To display a list of RACADM subcommands, type: racadm help
When run without options or subcommands, RACADM displays syntax information and instructions on how to access subcommands and help.
To list syntax and command-line options for individual subcommands, type: racadm help <subcommand>
70 Using the RACADM Command Line Interface
RACADM Subcommands
Table 4-1 provides a brief list of common subcommands used in RACADM.
For a complete list of RACADM subcommands, including syntax and valid entries, see the RACADM Subcommands chapter in the Command Line
Reference Guide for iDRAC6 and CMC .
NOTE: The connect command is available as both—RACADM command and builtin CMC command. The exit, quit, and logout commands are built-in CMC commands, not RACADM commands. None of these commands can be used with remote
RACADM. For information about using these commands, see "Connecting to
Servers or I/O Modules With the Connect Command" on page 61.
Table 4-1. RACADM Subcommands
Command help help < subcommand >
?
? < subcommand > arp chassisaction closessn clrraclog clrsel cmcchangeover config connect deploy
Description
Lists CMC subcommand descriptions.
Lists usage summary for the specified subcommand.
Lists CMC subcommand descriptions.
Lists usage summary for the specified subcommand.
Displays the contents of the ARP table. ARP table entries may not be added or deleted.
Executes power-up, power-down, reset, and power-cycle on the chassis, switch, and KVM.
Closes a session.
Clears the CMC log and creates a single entry indicating the user and time that the log was cleared.
Clears the System Event Log entries.
Changes the state of the CMC from active to standby, or vice versa, in redundant CMC environments.
Configures the CMC.
Connects to the serial console of a server or I/O module.
See "Connecting to Servers or I/O Modules With the
Connect Command" on page 61 for help using the
connect subcommand.
Deploys a server by specifying required properties.
Using the RACADM Command Line Interface 71
72
Table 4-1. RACADM Subcommands (continued)
Command feature featurecard fwupdate getassettag getchassisname getconfig getdcinfo getflexaddr getioinfo getkvminfo getled getmacaddress getmodinfo getniccfg getpbinfo getpminfo getraclog getractime getredundancymode getsel getsensorinfo getslotname getssninfo getsvctag
Description
Displays active features and feature deactivation.
Displays feature card status information.
Performs system component firmware updates, and displays firmware update status.
Displays the asset tag for the chassis.
Displays the name of the chassis.
Displays the current CMC configuration properties.
Displays general I/O module and daughter card misconfiguration information.
Displays the FlexAddress enabled/disabled status on a per slot/fabric basis. If used with the -i option, the command displays the WWN and MAC address for a particular slot.
Displays general I/O module information.
Displays information about the iKVM.
Displays the LED settings on a module.
Displays a server’s MAC address.
Displays module configuration and status information.
Displays the current IP configuration for the controller.
Displays power budget status information.
Displays power management status information.
Displays the CMC log.
Displays the CMC time.
Displays the redundancy mode of the CMC.
Displays the system event log (hardware log).
Displays information about system sensors.
Displays the name of a slot in the chassis.
Displays information about active sessions.
Displays service tags.
Using the RACADM Command Line Interface
Table 4-1. RACADM Subcommands (continued)
Command getsysinfo gettracelog getversion
Description
Displays general CMC and system information.
Displays the CMCtrace log. If used with the -i option, the command displays the number of entries in the CMC trace log.
Displays the current software version, model information, and whether or not the device can be updated.
krbkeytabupload netstat ping ping6 racdump racreset racresetcfg remoteimage serveraction setassettag setchassisname setflexaddr setled setniccfg setractime
Uploads a Kerberos Keytab to the CMC.
Displays the routing table and the current connections.
Verifies that the destination IPv4 address is reachable from the CMC with the current routing-table contents.
Verifies that the destination IPv6 address is reachable from the CMC with the current routing-table contents.
Displays the comprehensive chassis status and configuration state information, as well as historic event logs. Used for post deployment configuration verification and during debugging sessions.
Resets the CMC.
Resets the CMC to the default configuration.
Connects, disconnects, or deploys a media file on a remote server
Performs power management operations on the managed system.
Sets the asset tag for the chassis.
Sets the name of the chassis.
Enables/disables FlexAddress on a particular slot/fabric, when the FlexAddress feature is activated on the chassis
Sets the LED settings on a module.
Sets the IP configuration for the controller.
Sets the CMC time.
Using the RACADM Command Line Interface 73
74
Table 4-1. RACADM Subcommands (continued)
Command setslotname setsysinfo sshpkauth sslcertdownload sslcertupload sslcertview sslcsrgen sslresetcfg testemail testfeature testtrap traceroute traceroute6
Description
Sets the name of a slot in the chassis.
Sets the name and location of the chassis.
Uploads up to 6 different SSH public keys, deletes existing keys, and views the keys already in the CMC.
Downloads a certificate authority-signed certificate.
Uploads a certificate authority-signed certificate or server certificate to the CMC.
Views a certificate authority-signed certificate or server certificate in the CMC.
Generates and downloads the SSL CSR.
Regenerates the self-signed certificate used by the CMC
Web GUI.
Forces the CMC to send an e-mail over the CMC NIC.
Allow you to verify a specific feature's configuration parameters. For example, it supports testing the Active
Directory configuration using simple authentication (user name and password) or Active Directory configuration using Kerberos authentication (Single Sign-on or Smart
Card Login).
Forces the CMC to send an SNMP over the CMC
Network Interface.
Prints the route the IPv4 packets take to a network node.
Prints the route the IPv6 packets take to a network node.
Accessing RACADM Remotely
Table 4-2. Remote RACADM Subcommand Options
Option
-r < racIpAddr >
-r < racIpAddr >:< port >
Description
Specifies the controller’s remote IP address.
Use <port number> if the CMC port number is not the default port (443)
Using the RACADM Command Line Interface
Table 4-2. Remote RACADM Subcommand Options (continued)
Option
-i
-u < usrName >
-p < password >
Description
Instructs RACADM to interactively query the user for user name and password.
Specifies the user name that is used to authenticate the command transaction. If the
-u option is used, the -p option must be used, and the -i option (interactive) is not allowed.
Specifies the password used to authenticate the command transaction. If the -p option is used, the -i option is not allowed.
To access RACADM remotely, type the following commands: racadm -r <CMC IP address> -u <username> -p <password>
<subcommand> <subcommand options> racadm -i -r <CMC IP address> <subcommand> <subcommand options>
NOTE: The -i option instructs RACADM to interactively prompt for user name and password. Without the -i option, you must provide the user name and password in the command using the -u and -p options.
For example: racadm -r 192.168.0.120 -u root -p calvin getsysinfo racadm -i -r 192.168.0.120 getsysinfo
If the HTTPS port number of the CMC has been changed to a custom port other than the default port (443), the following syntax must be used: racadm -r <CMC IP address>:<port> -u <username> -p
<password> <subcommand> <subcommand options> racadm -i -r <CMC IP address>:<port> <subcommand>
<subcommand options>
Using the RACADM Command Line Interface 75
Enabling and Disabling the RACADM Remote Capability
NOTE: Dell recommends that you run these commands at the chassis.
The RACADM remote capability on the CMC is enabled by default. In the following commands, g specifies the configuration group the object belongs to, and -o specifies the configuration object to configure.
To disable the RACADM remote capability, type: racadm config -g cfgRacTuning -o cfgRacTuneRemoteRacadmEnable 0
To re-enable RACADM remote capability, type: racadm config -g cfgRacTuning -o cfgRacTuneRemoteRacadmEnable 1
Using RACADM Remotely
NOTE: Configure the IP address on your CMC before using the RACADM remote
capability. For more information about setting up your CMC, see "Installing and
Setting Up the CMC" on page 29.
The RACADM console’s remote option ( -r ) allows you to connect to the managed system and execute RACADM subcommands from a remote console or management station. To use the remote capability, you need a valid user name ( -u option) and password ( -p option), and the
CMC IP address.
Before you try to access RACADM remotely, confirm that you have permissions to do so. To display your user privileges, type: racadm getconfig -g cfguseradmin -i n where n is your user ID (1–16).
76 Using the RACADM Command Line Interface
If you do not know your user ID, try different values for n .
NOTE: The RACADM remote capability is supported only on management stations through a supported browser. For more information, see the Supported Browsers section in the Dell Systems Software Support Matrix support.dell.com/manuals.
on the Dell Support website at
NOTE: When using the RACADM remote capability, you must have write permissions on the folders where you are using the RACADM subcommands involving file operations. For example: racadm getconfig -f < file name > -r <IP address> or racadm sslcertupload -t 1 -f c:\cert\cert.txt
When using remote RACADM to capture the configuration groups into a file, if a key property within a group is not set, the configuration group is not saved as part of the configuration file. If these configuration groups are needed to be cloned onto other CMCs, the key property must be set before executing the getconfig -f command. Alternatively, you can manually enter the missing properties into the configuration file after running the getconfig
-f command. This is true for all the racadm indexed groups.
This is the list of the indexed groups that exhibit this behavior and their corresponding key properties: cfgUserAdmin - cfgUserAdminUserName cfgEmailAlert - cfgEmailAlertAddress cfgTraps - cfgTrapsAlertDestIPAddr cfgStandardSchema - cfgSSADRoleGroupName cfgServerInfo - cfgServerBmcMacAddress
RACADM Error Messages
For information about RACADM CLI error messages, see "Troubleshooting" on page 101.
Using the RACADM Command Line Interface 77
Using RACADM to Configure the CMC
NOTE: In order to configure CMC the first time, you must be logged in as user root to execute RACADM commands on a remote system. Another user can be created with priviliges to configure the CMC.
The CMC Web interface is the quickest way to configure the CMC (see
"Using the CMC Web Interface" on page 103
) . However, if you prefer CLI or script configuration or need to configure multiple CMCs, use Remote
RACADM, which is installed with the CMC agents on the management station.
Configuring CMC Network Properties
Before you can begin configuring the CMC, you must first configure the
CMC network settings to allow the CMC to be managed remotely.
This initial configuration assigns the TCP/IP networking parameters that enable access to the CMC.
Setting Up Initial Access to the CMC
This section explains how to perform the initial CMC network configuration using RACADM commands. All of the configuration described in this section
can be performed using the front panel LCD. See "Configuring Networking
Using the LCD Configuration Wizard" on page 41.
CAUTION: Changing settings on the CMC Network Settings screen may disconnect your current network connection.
For more information about network subcommands, see the
RACADM Subcommands and Property Database Group and
Object Definitions chapters of the Command Line Reference Guide for iDRAC6 and CMC .
NOTE: You must have Chassis Configuration Administrator privilege to set up CMC network settings.
The CMC supports both IPv4 and IPv6 addressing modes. The configuration settings for IPv4 and IPv6 are independent of one another.
78 Using the RACADM Command Line Interface
Viewing Current IPv4 Network Settings
To view a summary of NIC, DHCP, network speed, and duplex settings, type: racadm getniccfg or racadm getconfig -g cfgCurrentLanNetworking
Viewing Current IPv6 Network Settings
To view a summary of the network settings, type: racadm getconfig -g cfgIpv6LanNetworking
To view IPv4 and IPv6 addressing information for the chassis type: racadm getsysinfo
By default, the CMC requests and obtains a CMC IP address from the
Dynamic Host Configuration Protocol (DHCP) server automatically.
You can disable this feature and specify static CMC IP address, gateway, and subnet mask.
To disable DHCP and specify static CMC IP address, gateway, and subnet mask, type: racadm config -g cfgLanNetworking -o cfgNicUseDHCP 0 racadm config -g cfgLanNetworking -o cfgNicIpAddress
< static IP address > racadm config -g cfgLanNetworking -o cfgNicGateway
< static gateway > racadm config -g cfgLanNetworking -o cfgNicNetmask
< static subnet mask >
Viewing Current Network Settings
To view a summary of NIC, DHCP, network speed, and duplex settings, type: racadm getniccfg or racadm getconfig -g cfgCurrentLanNetworking
Using the RACADM Command Line Interface 79
To view IP address and DHCP, MAC address, and DNS information for the chassis, type: racadm getsysinfo
Configuring the Network LAN Settings
NOTE: To perform the following steps, you must have Chassis Configuration
Administrator privilege.
NOTE: The LAN settings, such as community string and SMTP server IP address, affect both the CMC and the external settings of the chassis.
NOTE: If you have two CMCs (active and standby) on the chassis, and they are connected to the network, the standby CMC automatically assumes the network settings of the active CMC in the event of failover.
NOTE: When IPv6 is enabled at boot time, three router solicitations are sent every four seconds. If external network switches are running the Spanning Tree Protocol
(SPT), the external switch ports may be blocked for more than twelve seconds in which the IPv6 router solicitations are sent. In such cases, there may be a period when IPv6 connectivity is limited, until router advertisements are gratuitously sent by the IPv6 routers.
Enabling the CMC Network Interface
To enable/disable the CMC Network Interface for both IPv4 and IPv6, type: racadm config -g cfgLanNetworking -o cfgNicEnable 1 racadm config -g cfgLanNetworking -o cfgNicEnable 0
NOTE: The CMC NIC is enabled by default.
To enable/disable the CMC IPv4 addressing, type: racadm config -g cfgLanNetworking -o cfgNicIPv4Enable
1 racadm config -g cfgLanNetworking -o cfgNicIPv4Enable
0
NOTE: The CMC IPv4 addressing is enabled by default.
80 Using the RACADM Command Line Interface
To enable/disable the CMC IPv6 addressing, type: racadm config -g cfgIpv6LanNetworking -o cfgIPv6Enable
1 racadm config -g cfgIpv6LanNetworking -o cfgIPv6Enable
0
NOTE: The CMC IPv6 addressing is disabled by default.
By default, for IPv4, the CMC requests and obtains a CMC IP address from the Dynamic Host Configuration Protocol (DHCP) server automatically. You can disable the DHCP feature and specify static CMC IP address, gateway, and subnet mask.
For an IPv4 network, to disable DHCP and specify static CMC IP address, gateway, and subnet mask, type: racadm config -g cfgLanNetworking -o cfgNicUseDHCP 0 racadm config -g cfgLanNetworking -o cfgNicIpAddress
<static IP address> racadm config -g cfgLanNetworking -o cfgNicGateway
<static gateway> racadm config -g cfgLanNetworking -o cfgNicNetmask
<static subnet mask>
By default, for IPv6, the CMC requests and obtains a CMC IP address from the IPv6 Autoconfiguration mechanism automatically.
For an IPv6 network, to disable the Autoconfiguration feature and specify a static CMC IPv6 address, gateway, and prefix length, type: racadm config -g cfgIPv6LanNetworking -o cfgIPv6AutoConfig 0 racadm config -g cfgIPv6LanNetworking -o cfgIPv6Address <IPv6 address> racadm config -g cfgIPv6LanNetworking -o cfgIPv6PrefixLength 64 racadm config -g cfgIPv6LanNetworking -o cfgIPv6Gateway <IPv6 address>
Using the RACADM Command Line Interface 81
Enabling or Disabling DHCP for the CMC Network Interface Address
When enabled, the CMC’s DHCP for NIC address feature requests and obtains an IP address from the Dynamic Host Configuration Protocol
(DHCP) server automatically. This feature is enabled by default.
You can disable the DHCP for NIC address feature and specify a static
IP address, subnet mask, and gateway. For more information, see "Setting Up
Initial Access to the CMC" on page 78.
Enabling or Disabling DHCP for DNS IP Addresses
By default, the CMC’s DHCP for DNS address feature is disabled.
When enabled, this feature obtains the primary and secondary DNS server addresses from the DHCP server. While using this feature, you do not have to configure static DNS server IP addresses.
To disable the DHCP for DNS address feature and specify static preferred and alternate DNS server addresses, type: racadm config -g cfgLanNetworking -o cfgDNSServersFromDHCP 0
To disable the DHCP for DNS address feature for IPv6 and specify static preferred and alternate DNS server addresses, type: racadm config -g cfgIPv6LanNetworking -o cfgIPv6DNSServersFromDHCP6 0
Setting Static DNS IP addresses
NOTE: The Static DNS IP addresses settings are not valid unless the DCHP for DNS address feature is disabled.
For IPv4, to set the preferred primary and secondary DNS IP server addresses, type: racadm config -g cfgLanNetworking -o cfgDNSServer1
< IP-address > racadm config -g cfgLanNetworking -o cfgDNSServer2
<IPv4-address>
82 Using the RACADM Command Line Interface
For IPv6, to set the preferred and secondary DNS IP Server addresses, type: racadm config -g cfgIPv6LanNetworking -o cfgIPv6DNSServer1 <IPv6-address> racadm config -g cfgIPv6LanNetworking -o cfgIPv6DNSServer2 <IPv6-address>
Configuring DNS Settings (IPv4 and IPv6)
• CMC Registration — To register the CMC on the DNS server, type: racadm config -g cfgLanNetworking -o cfgDNSRegisterRac 1
NOTE: Some DNS servers only register names of 31 characters or fewer.
Make sure the designated name is within the DNS required limit.
NOTE: The following settings are valid only if you have registered the CMC on the DNS server by setting cfgDNSRegisterRac to 1.
• CMC Name.
By default, the CMC name on the DNS server is cmc-
<service tag>. To change the CMC name on the DNS server, type: racadm config -g cfgLanNetworking -o cfgDNSRacName
< name > where < name > is a string of up to 63 alphanumeric characters and hyphens. For example, cmc-1, d-345.
• DNS Domain Name.
The default DNS domain name is a single blank character. To set a DNS domain name, type: racadm config -g cfgLanNetworking -o cfgDNSDomainName < name > where < name > is a string of up to 254 alphanumeric characters and hyphens. For example: p45, a-tz-1, r-id-001.
Configuring Auto Negotiation, Duplex Mode, and Network Speed (IPv4 and IPv6)
When enabled, the auto negotiation feature determines whether the
CMC automatically sets the duplex mode and network speed by communicating with the nearest router or switch. Auto negotiation is enabled by default.
Using the RACADM Command Line Interface 83
84
You can disable auto negotiation and specify the duplex mode and network speed by typing: racadm config -g cfgNetTuning -o cfgNetTuningNicAutoneg 0 racadm config -g cfgNetTuning -o cfgNetTuningNicFullDuplex
<duplex mode> where:
< duplex mode > is 0 (half duplex) or 1 (full duplex, default) racadm config -g cfgNetTuning -o cfgNetTuningNicSpeed
<speed> where:
< speed > is 10 or 100(default).
Setting up the CMC VLAN (IPv4 and IPv6)
1 Enable the VLAN capabilities of the external chassis management network: racadm config -g cfgLanNetworking -o cfgNicVLanEnable 1
2 Specify the VLAN ID for the external chassis management network: racadm config -g cfgLanNetworking -o cfgNicVlanID
<VLAN id>
The valid values for <VLAN id> are 1– 4000 and 4021– 4094. Default is 1.
For example: racadm config -g cfgLanNetworking -o cfgNicVlanID
1
3 Then, specify the VLAN priority for the external chassis management network: racadm config -g cfgLanNetworking -o cfgNicVLanPriority <VLAN priority>
The valid values for <VLAN priority> are 0–7. Default is 0.
For example: racadm config -g cfgLanNetworking -o cfgNicVLanPriority 7
Using the RACADM Command Line Interface
You can also specify both the VLAN ID and the VLAN priority with a single command: racadm setniccfg -v <VLAN id> <VLAN priority>
For example: racadm setniccfg -v 1 7
Removing the CMC VLAN
To remove the CMC VLAN, disable the VLAN capabilities of the external chassis management network: racadm config -g cfgLanNetworking -o cfgNicVLanEnable
0
You can also remove the CMC VLAN using the following command: racadm setniccfg -v
Setting up a Server VLAN
Specify the VLAN ID and priority of a particular server with the following command: racadm setniccfg -m server-<n> -v <VLAN id> <VLAN priority>
The valid values for <n> are 1 – 16.
The valid values for <VLAN id> are 1 – 4000 and 4021 – 4094. Default is 1.
The valid values for <VLAN priority> are 0 – 7. Default is 0.
For example: racadm setniccfg -m server-1 -v 1 7
Using the RACADM Command Line Interface 85
Removing a Server VLAN
To remove a server VLAN, disable the VLAN capabilities of the specified server's network: racadm setniccfg -m server-<n> -v
The valid values for <n> are 1-16.
For example: racadm setniccfg -m server-1 -v
Setting the Maximum Transmission Unit (MTU) (IPv4 and IPv6)
The MTU property allows you to set a limit for the largest packet that can be passed through the interface. To set the MTU, type: racadm config -g cfgNetTuning -o cfgNetTuningMtu < mtu > where < mtu > is a value between 576–1500 (inclusive; default is 1500).
NOTE: IPv6 requires a minimum MTU of 1280. If IPv6 is enabled, and cfgNetTuningMtu is set to a lower value, the CMC uses an MTU of 1280.
Setting the SMTP Server IP Address (IPv4 and IPv6)
You can enable the CMC to send e-mail alerts using Simple Mail Transfer
Protocol (SMTP) to a specified IP address. To enable this feature, type: racadm config -g cfgRemoteHosts -o cfgRhostsSmtpServerIpAddr < SMTP IP address > where < SMTP IP address > is the IP address of the network SMTP server.
NOTE: If your network has an SMTP server that releases and renews IP address leases periodically, and the addresses are different, then there is a duration when this property setting does not work due to change in the specified SMTP server IP address. In such cases, use the DNS name.
Configuring the Network Security Settings
(IPv4 Only)
NOTE: To perform the following steps, you must have Chassis Configuration
Administrator privilege.
86 Using the RACADM Command Line Interface
Enabling IP Range Checking (IPv4 Only)
IP filtering compares the IP address of an incoming login to the IP address range that is specified in the following cfgRacTuning properties:
• cfgRacTuneIpRangeAddr
• cfgRacTuneIpRangeMask
A login from the incoming IP address is allowed only if both the following are identical:
• cfgRacTuneIpRangeMask bit-wise and with incoming IP address
• cfgRacTuneIpRangeMask bit-wise and with cfgRacTuneIpRangeAddr
Using RACADM to Configure Users
Before You Begin
You can configure up to 16 users in the CMC property database. Before you manually enable a CMC user, verify if any current users exist. If you are configuring a new CMC or you ran the RACADM racresetcfg command, the only current user is root with the password calvin . The racresetcfg subcommand resets the CMC back to the original defaults.
CAUTION: Use caution when using the racresetcfg command, because it resets all are lost.
configuration parameters to the original defaults. Any previous changes
NOTE: Users can be enabled and disabled over time, and disabling a user does not delete the user from the database.
To verify if a user exists, open a Telnet/SSH text console to the CMC, log in, and type the following command once for each index of 1–16: racadm getconfig -g cfgUserAdmin -i < index >
Several parameters and object IDs are displayed with their current values.
Two objects of interest are:
# cfgUserAdminIndex=XX cfgUserAdminUserName=
If the cfgUserAdminUserName object has no value, that index number, which is indicated by the cfgUserAdminIndex object, is available for use.
If a name appears after the " = ," that index is taken by that user name.
Using the RACADM Command Line Interface 87
NOTE: When you manually enable or disable a user with the RACADM config subcommand, you must specify the index with the -i option. Observe that the cfgUserAdminIndex object displayed in the previous example contains a # character. Also, if you use the racadm config -f racadm.cfg
command to specify any number of groups/objects to write, the index cannot be specified.
A new user is added to the first available index. This behavior allows more flexibility in configuring a second CMC with the same settings as the main CMC.
Adding a CMC User
To add a new user to the CMC configuration, you can use a few basic commands. Perform the following procedures:
1 Set the user name.
2 Set the password.
3
Set user privileges. For information about user privileges, see Table 5-40,
and Table 5-41 in the database property chapter of the
Command Line
Reference Guide for iDRAC6 and CMC .
4 Enable the user.
Example
The following example describes how to add a new user named "John" with a
"123456" password and LOGIN privilege to the CMC.
NOTE: See Table 3-1 in the database property chapter of the Command Line
Reference Guide for iDRAC6 and CMC for a list of valid bit mask values for specific user privileges. The default privilege value is 0, which indicates the user has no privileges enabled.
racadm config -g cfgUserAdmin -o cfgUserAdminUserName
-i 2 john racadm config -g cfgUserAdmin -o cfgUserAdminPassword
-i 2 123456 racadm config -g cfgUserAdmin -i 2 -o cfgUserAdminPrivilege 0x00000001 racadm config -g cfgUserAdmin -i 2 -o cfgUserAdminEnable 1
88 Using the RACADM Command Line Interface
To verify that the user was added successfully with the correct privileges, type the following command: racadm getconfig –g cfgUserAdmin –i 2
Using RACADM to Configure Public Key
Authentication over SSH
Before You Begin
You can configure up to 6 public keys that can be used with the service username over SSH interface. Before adding or deleting public keys, be sure to use the view command to see what keys are already set up so a key is not accidentally overwritten or deleted. The service username is a special user account that can be used when accessing the CMC through SSH. When the
PKA over SSH is set up and used correctly, you need not enter username or passwords to log in to the CMC. This can be very useful to set up automated scripts to perform various functions.
When getting ready to set up this functionality, be aware of the following:
• there is no GUI support for managing this feature; you can only use
RACADM
• when adding new public keys, ensure that the existing keys are not already at the index where the new key is added. CMC does not perform checks to ensure previous keys are deleted before a new one is added. As soon as a new key is added, it is automatically in effect as long as the SSH interface is enabled.
• when using the public key comment section of the public key, remember that only the first 16 characters are utilized by the CMC. The public key comment is used by the CMC to distinguish SSH users when using the
RACADM getssninfo command since all PKA users use the service username to log in.
Using the RACADM Command Line Interface 89
90
For example, if two public keys are set up one with comment PC1 and one with comment PC2: racadm getssninfo
Type User IP Address Login Date/Time
SSH PC1 x.x.x.x 06/16/2009 09:00:00
SSH PC2 x.x.x.x 06/16/2009 09:00:00
For more information on the sshpkauth , see the Command Line
Reference Guide for iDRAC6 and CMC .
Generating Public Keys for Windows
Before adding an account, a public key is required from the system that accesses the CMC over SSH. There are two ways to generate the public/private key pair: using PuTTY Key Generator application for clients running Windows or ssh-keygen CLI for clients running Linux.
This section describes simple instructions to generate a public/private key pair for both applications. For additional or advanced usage of these tools, see the application Help.
To use the PuTTY Key Generator for Windows clients to create the basic key:
1 Start the application and select SSH-2 RSA or SSH-2 DSA for the type of key to generate (SSH-1 is not supported).
2 Enter the number of bits for the key. The number should be between 768 and 4096.
NOTE: The CMC may not display a message if you add keys less than 768 or greater than 4096, but when you try to log in, these keys it fails.
3 Click Generate and move the mouse in the window as directed.
After the key is created, you can modify the key comment field.
You can also enter a passphrase to make the key secure. Ensure that you save the private key.
4 You have two options for using the public key:
• save the public key to a file to upload later
• copy and paste the text from the Public key for pasting… window when adding the account using the text option
Using the RACADM Command Line Interface
Generating Public Keys for Linux
The ssh-keygen application for Linux clients is a command line tool with no graphical user interface. Open a terminal window and at the shell prompt type: ssh-keygen –t rsa –b 1024 –C testing where,
–t option must be dsa or rsa.
–b option specifies the bit encryption size between 768 and 4096.
–C option allows modifying the public key comment and is optional.
the passphrase is optional.
Follow the instructions. After the command completes, use the public file to pass to the RACADM for uploading the file.
RACADM Syntax Notes for CMC
When using the racadm sshpkauth command, ensure the following:
• For the –i option, the parameter must be svcacct . All other parameters for i fail in CMC. The svcacct is a special account for public key authentication over SSH in CMC.
• To log in to the CMC, the user must be service . Users of the other categories do have access to the public keys entered using the sshpkauth command.
Viewing the Public Keys
To view public keys that you have added to the CMC, type: racadm sshpkauth –i svcacct –k all –v
To view just one key at a time, replace all with a number from 1 – 6. For example, to view key 2, type: racadm sshpkauth –i svcacct –k 2 –v
Using the RACADM Command Line Interface 91
92
Adding the Public Keys
To add a public key to the CMC using the file upload (-f) option, type: racadm sshpkauth –i svcacct –k 1 –p 0xfff –f <public key file>
NOTE: You can only use the file upload option with remote RACADM. For more
information, see "Accessing RACADM Remotely" on page 74 and subsequent
sections.
For public key privileges, see Table 3-1 in the Database Property chapter of
Dell Chassis Management Controller Administrator Reference Guide .
To add a public key using the text upload option, type: racadm sshpkauth –i svcacct –k 1 –p 0xfff –t “<public key text>”
Deleting the Public Keys
To delete a public key type: racadm sshpkauth –i svcacct –k 1 –d
To delete all public keys type: racadm sshpkauth –i svcacct –k all –d
Logging in Using Public Key Authentication
After the public keys are uploaded, you should be able to log into the CMC over SSH without having to enter a password. You also have the option of sending a single RACADM command as a command line argument to the
SSH application. The command line options behave like remote RACADM since the session ends after the command is completed. For example:
Logging in: ssh service@<domain>
Or ssh service@< IP_address > where <IP_address> is the IP address of the CMC.
Sending racadm commands: ssh service@<domain> racadm getversion
Using the RACADM Command Line Interface
ssh service@<domain> racadm getsel
When you log in using the service account, if a passphrase was set up when creating the public/private key pair, you may be prompted to enter that passphrase again. If a passphrase is used with the keys, both Windows and
Linux clients provide methods to automate that as well. For Windows clients, you can use the Pageant application. It runs in the background and makes entering the passphrase transparent. For Linux clients, you can use the sshagent. For setting up and using either of these applications, see the documentation provided from that application.
Enabling a CMC User With Permissions
To enable a user with specific administrative permissions (role-based authority), first locate an available user index by performing the steps in
"Before You Begin" on page 87. Next, type the following command lines with
the new user name and password.
racadm config -g cfgUserAdmin -o cfgUserAdminPrivilege -i <index> <user privilege bitmask value>
NOTE: See Table 3-1 in the Database Property chapter of the Dell Chassis
Management Controller Administrator Reference Guide for a list of valid bit mask values for specific user privileges. The default privilege value is 0, which indicates the user has no privileges enabled.
Disabling a CMC User
Using RACADM, you can only disable CMC users manually and on an individual basis. You cannot delete users by using a configuration file.
The following example illustrates the command syntax that can be used to delete a CMC user: racadm config -g cfgUserAdmin -i 2 cfgUserAdminPrivilege 0x0
Using the RACADM Command Line Interface 93
Configuring SNMP and E-mail Alerting
You can configure the CMC to send SNMP event traps and/or e-mail alerts when certain events occur on the chassis. For more information and
instructions, see "Configuring SNMP Alerts" on page 379 and "Configuring Email Alerts" on page 385.
You can specify the trap destinations as appropriately-formatted numeric addresses (IPv6 or IPv4), or Fully-qualified domain names (FQDNs).
Choose a format that is consistent with your networking technology/infrastructure.
NOTE: The Test TRAP functionality does not detect improper choices based on current network configuration. For example, using an IPv6 destination in an
IPv4-only environment.
Configuring Multiple CMCs in Multiple Chassis
Using RACADM, you can configure one or more CMCs with identical properties.
When you query a specific CMC card using its group ID and object ID,
RACADM creates the racadm.cfg
configuration file from the retrieved information. By exporting the file to one or more CMCs, you can configure your controllers with identical properties in a minimal amount of time.
NOTE: Some configuration files contain unique CMC information (such as the static
IP address) that must be modified before you export the file to other CMCs.
1 Use RACADM to query the target CMC that contains the desired configuration.
NOTE: The generated configuration file is myfile.cfg. You can rename the file.
NOTE: The .cfg file does not contain user passwords. When the .cfg file is uploaded to the new CMC, you must re-add all passwords.
2 Open a Telnet/SSH text console to the CMC, log in, and type: racadm getconfig -f myfile.cfg
NOTE: Redirecting the CMC configuration to a file using getconfig -f is only supported with the remote RACADM interface. For more information see
"Accessing RACADM Remotely" on page 74.
94 Using the RACADM Command Line Interface
3 Modify the configuration file using a plain-text editor (optional).
Any special formatting characters in the configuration file may corrupt the RACADM database.
4 Use the newly created configuration file to modify a target CMC.
At the command prompt, type: racadm config -f myfile.cfg
5 Reset the target CMC that was configured. At the command prompt, type: racadm reset
The getconfig -f myfile.cfg
subcommand (step 1) requests the CMC configuration for the active CMC and generates the myfile.cfg
file.
If required, you can rename the file or save it to a different location.
You can use the getconfig command to perform the following actions:
• Display all configuration properties in a group (specified by group name and index)
• Display all configuration properties for a user by user name
The config subcommand loads the information into other CMCs. The Server
Administrator uses the config command to synchronize the user and password database.
Creating a CMC Configuration File
The CMC configuration file, < filename >.cfg
, is used with the racadm config -f <filename>.cfg
command to create a simple text file.
The command allows you to build a configuration file (similar to a .ini
file) and configure the CMC from this file.
You may use any file name, and the file does not require a .cfg extension
(although it is referred to by that designation in this subsection).
NOTE: For more information about the getconfig subcommand, see the Command
Line Reference Guide for iDRAC6 and CMC .
RACADM parses the .cfg
file when it is first loaded onto the CMC to verify that valid group and object names are present and that some simple syntax rules are being followed. Errors are flagged with the line number that detected the error, and a message explains the problem. The entire file is
Using the RACADM Command Line Interface 95
parsed for correctness, and all errors display. Write commands are not transmitted to the CMC if an error is found in the .cfg
file. You must correct all errors before any configuration can take place.
To check for errors before you create the configuration file, use the c option with the config subcommand. With the c option, config only verifies syntax and does not write to the CMC.
Follow these guidelines when you create a .cfg
file:
• If the parser encounters an indexed group, it is the value of the anchored object that differentiates the various indexes.
The parser reads in all of the indexes from the CMC for that group.
Any objects within that group are modifications when the CMC is configured. If a modified object represents a new index, the index is created on the CMC during configuration.
• You cannot specify a desired index in a .cfg
file.
Indexes may be created and deleted. Over time the group may become fragmented with used and unused indexes. If an index is present, it is modified. If an index is not present, the first available index is used.
This method allows flexibility when adding indexed entries where you do not need to make exact index matches between all the CMCs being managed. New users are added to the first available index. A .cfg
file that parses and runs correctly on one CMC may not run correctly on another if all indexes are full and you must add a new user.
• Use the racresetcfg subcommand to configure both CMCs with identical properties.
Use the racresetcfg subcommand to reset the CMC to original defaults, and then run the racadm config -f <filename>.cfg
command. Ensure that the .cfg
file includes all desired objects, users, indexes, and other parameters. See the database property chapter of the
Command Line Reference Guide for iDRAC6 and CMC for a complete list of objects and groups.
CAUTION: Use the racresetcfg subcommand to reset the database and the CMC Network Interface settings to the original default settings and remove all users and user configurations. While the root user is available, other users’ settings are also reset to the default settings.
96 Using the RACADM Command Line Interface
Parsing Rules
• Lines that start with a hash character (#) are treated as comments.
A comment line must start in column one. A "#" character in any other column is treated as a # character.
Some modem parameters may include # characters in their strings.
An escape character is not required. You may want to generate a .cfg
from a racadm getconfig -f <filename> .cfg
command, and then perform a racadm config -f <filename> .cfg
command to a different CMC, without adding escape characters.
For Example:
#
# This is a comment
[cfgUserAdmin] cfgUserAdminPageModemInitString=<Modem init # not a comment>
• All group entries must be surrounded by open- and close-brackets ([ and ] ) .
The starting [ character that denotes a group name must be in column one. This group name must be specified before any of the objects in that group. Objects that do not include an associated group name generate an error. The configuration data is organized into groups as defined in the database property chapter of the Command Line Reference Guide for iDRAC6 and CMC .
The following example displays a group name, object, and the object’s property value:
[cfgLanNetworking] -{ group name } cfgNicIpAddress=143.154.133.121 { object name }
{ object value }
• All parameters are specified as "object=value" pairs with no white space between the object, =, or value.
White spaces that are included after the value are ignored. A white space inside a value string remains unmodified. Any character to the right of the
= (for example, a second =, a #, [, ], and so on) is taken as-is.
These characters are valid modem chat script characters.
Using the RACADM Command Line Interface 97
98
[cfgLanNetworking] -{ group name } cfgNicIpAddress=143.154.133.121 { object value}
• The .cfg
parser ignores an index object entry.
You cannot specify which index is used. If the index already exists, it is either used or the new entry is created in the first available index for that group.
The racadm getconfig -f <filename> .cfg
command places a comment in front of index objects, allowing you to see the included comments.
NOTE: You may create an indexed group manually using the following command: racadm config -g <groupName> -o <anchored object> -i <index 1–16> <unique anchor name>
• The line for an indexed group cannot be deleted from a .cfg
file. If you do delete the line with a text editor, RACADM stops when it parses the configuration file and alert you of the error.
You must remove an indexed object manually using the following command: racadm config -g < groupName > -o < objectName > -i
< index 1–16 > ""
NOTE: A NULL string (identified by two " characters) directs the CMC to delete the index for the specified group.
To view the contents of an indexed group, run the following command: racadm getconfig -g < groupName > -i < index 1–16 >
• For indexed groups the object anchor must be the first object after the [ ] pair.
The following are examples of the current indexed groups:
[cfgUserAdmin] cfgUserAdminUserName=< USER_NAME >
If you type racadm getconfig -f < myexample >.cfg
, the command builds a .cfg
file for the current CMC configuration.
Using the RACADM Command Line Interface
This configuration file can be used as an example and as a starting point for your unique .cfg
file.
Modifying the CMC IP Address
When you modify the CMC IP address in the configuration file, remove all unnecessary < variable >= <value> entries. Only the actual variable group’s label with [ and ] remains, including the two < variable >=
<value> entries pertaining to the IP address change.
Example:
#
# Object Group " cfgLanNetworking "
#
[cfgLanNetworking] cfgNicIpAddress=10.35.10.110
cfgNicGateway=10.35.10.1
This file is updated as follows:
#
# Object Group " cfgLanNetworking "
#
[cfgLanNetworking] cfgNicIpAddress=10.35.9.143
# comment, the rest of this line is ignored cfgNicGateway=10.35.9.1
The command racadm config -f < myfile >.cfg
parses the file and identifies any errors by line number. A correct file updates the proper entries.
Additionally, you can use the same getconfig command from the previous example to confirm the update.
Use this file to download company-wide changes or to configure new systems over the network with the command, racadm getconfig -f
< myfile >.cfg
.
NOTE: Anchor is a reserved word and should not be used in the .cfg file.
Using the RACADM Command Line Interface 99
100
Using RACADM to Configure Properties on iDRAC
RACADM config/getconfig commands support the -m <module> option for the following configuration groups:
• cfgLanNetworking
• cfgIPv6LanNetworking
• cfgRacTuning
• cfgRemoteHosts
• cfgSerial
• cfgSessionManagement
NOTE: For more information on the property default values and ranges, see the
Integrated Dell Remote Access Controller 6 (iDRAC6) Enterprise for Blade Servers
User Guide .
If the firmware on the server does not support a feature, configuring a property related to that feature displays an error. For example, using
RACADM to enable remote syslog on an unsupported iDRAC displays an error message.
Similarly, when displaying the iDRAC properties using the RACADM getconfig command, the property values are displayed as N/A for an unsupported feature on the server.
For example:
$ racadm getconfig -g cfgSessionManagement -m server-1
# cfgSsnMgtWebServerMaxSessions=N/A
# cfgSsnMgtWebServerActiveSessions=N/A
# cfgSsnMgtWebServerTimeout=N/A
# cfgSsnMgtSSHMaxSessions=N/A
# cfgSsnMgtSSHActiveSessions=N/A
# cfgSsnMgtSSHTimeout=N/A
# cfgSsnMgtTelnetMaxSessions=N/A
# cfgSsnMgtTelnetActiveSessions=N/A
# cfgSsnMgtTelnetTimeout=N/A
Using the RACADM Command Line Interface
Troubleshooting
Table 4-3 lists common problems related to remote RACADM.
Table 4-3. Using Serial/ RACADM Commands: Frequently Asked Questions
Question Answer
After performing a CMC reset
(using the RACADM racreset subcommand), I enter a command and the following message is displayed: racadm <subcommand>
Transport: ERROR:
(RC=-1)
What does this message mean?
When I use the RACADM subcommands, I get errors that I do not understand.
You must wait until the CMC completes the reset before issuing another command.
You may encounter one or more of the following errors when using RACADM:
• Local error messages — Problems such as syntax, typographical errors, and incorrect names. Example:
ERROR: <message>
Use the RACADM help subcommand to display correct syntax and usage information.
• CMC-related error messages — Problems where the
CMC is unable to perform an action. Also might say
"racadm command failed."
Type racadm gettracelog for debugging information.
Using the RACADM Command Line Interface 101
Table 4-3. Using Serial/ RACADM Commands: Frequently Asked Questions (continued)
Question Answer
While I was using remote
RACADM, the prompt changed to a ">" and I cannot get the "$" prompt to return.
If you type a non-matched double quotation mark (") or a non-matched single quotation (’) in the command, the CLI changes to the ">" prompt and queue all commands.
To return to the "$" prompt, type <Ctrl>–d.
I tried using the following commands and received an error saying "Not Found":
The logout and quit commands are not supported in the CMC CLI interface.
$ logout
$ quit
102 Using the RACADM Command Line Interface
5
Using the CMC Web Interface
CMC provides a Web interface that enables you to configure CMC properties and users, perform remote management tasks, and troubleshoot a remote (managed) system for problems. For everyday chassis management, use the CMC Web interface. This chapter provides information about how to perform common chassis management tasks using the CMC Web interface.
You can also perform all configuration tasks using local RACADM commands or command line consoles (serial console, Telnet, or SSH). For more
information about using local RACADM, see "Using the RACADM
Command Line Interface" on page 69. For information on using command
line consoles, see "Configuring CMC to Use Command Line Consoles" on page 55.
NOTE: If you are using Microsoft Internet Explorer, connecting through a proxy, and see the error "The XML page cannot be displayed," you need to disable the proxy to continue.
Accessing the CMC Web Interface
To access the CMC Web interface over IPv4:
1 Open a supported Web browser window.
For the latest information on supported Web browsers, see the
Dell Systems Software Support Matrix located on the Dell Support website at support.dell.com/manuals .
2 Type the following URL in the Address field, and then press <Enter>: https://< CMC IP address >
If the default HTTPS port number (port 443) has been changed: https://<CMC IP address>:<port number> where <CMC IP address> is the IP address for CMC and <port number> is the HTTPS port number.
The CMC Login page appears.
103 Using the CMC Web Interface
To access the CMC Web interface over IPv6:
1 Open a supported Web browser window.
For the latest information on supported Web browsers, see the
Dell Systems Software Support Matrix located on the Dell Support website at support.dell.com/manuals .
2 Type the following URL in the Address field, and then press <Enter>: https://[< CMC IP address> ]
NOTE: While using IPv6, you must enclose the <CMC IP address> in square brackets ([ ]).
Specifying the HTTPS port number in the URL is optional if you are still using the default value (443). Otherwise, you must specify the port number. The syntax for the IPv6 CMC URL with the port number specified is: https://[ <CMC IP address> ]:< port number > where <CMC IP address > is the IP address for CMC and <port number > is the HTTPS port number.
The CMC Login page appears.
Logging In
NOTE: To log in to CMC, you must have a CMC account with Log In to CMC privilege.
NOTE: The default CMC user name is root, and the password is calvin. The root account is the default administrative account that ships with CMC. For added security, it is strongly recommended that you change the default password of the root account during initial setup.
NOTE: CMC does not support extended ASCII characters, such as ß, å, é, ü, or other characters used primarily in non-English languages.
NOTE: You cannot log in to the Web interface with different user names in multiple browser windows on a single workstation.
104 Using the CMC Web Interface
You can log in as either a CMC user or as a Directory user.
To log in:
1 In the Username field, type your user name:
• CMC user name: <user name>
• Active Directory user name: <domain>\<user name> ,
<domain>/<user name> or <user>@<domain> .
• LDAP user name: <user name>
NOTE: This field is case sensitive.
2 In the Password field, type your CMC user password or Active Directory user password.
NOTE: This field is case-sensitive.
3 Optionally, select a session timeout. This is the amount of time you can stay logged in with no activity before you are automatically logged out. The default value is the Web Service Idle Timeout. See Configuring Services for more details.
4 Click OK or press <Enter>.
Logging Out
When you are logged in to the Web interface, you can log out at any time by clicking Logout in the upper right corner of any page.
NOTE: Be careful to apply (save) any settings or information you enter on a page.
If you log out or navigate away from that page without applying your changes, the changes are lost.
Configuring Basic CMC Settings
Setting the Chassis Name
You can set the name used to identify the chassis on the network.
(The default name is "Dell Rack System.") For example, an SNMP query on the chassis name returns the name you configure.
Using the CMC Web Interface 105
106
To set the chassis name:
1 Log in to the CMC Web interface. The Chassis Health page displays.
2 Click the Setup tab. The General Chassis Settings page displays.
3 Type the new name in the Chassis Name field, and then click Apply .
Setting the Date and Time on CMC
You can set the date and time manually, or you can synchronize the date and time with a Network Time Protocol (NTP) server.
1 Log in to the CMC Web interface. The Chassis Health page displays.
2 Click the Setup tab. The General Chassis Settings page displays.
3 Click the Date/Time subtab. The Date/Time page displays.
4 To synchronize the date and time with a Network Time Protocol (NTP) server, check Enable NTP and specify up to three NTP servers.
5 To set the date and time manually, uncheck Enable NTP and edit the
Date and Time fields, select the Time Zone from the drop-down menu, and then click Apply .
To set the date and time using the command line interface, see the config command and cfgRemoteHosts database property group sections in the
Command Line Reference Guide for iDRAC6 and CMC.
Chassis Health Page
When you log in to CMC, the Chassis Health page ( Chassis Overview ï‚®
Properties ï‚® Health ) is displayed. The most frequently needed information and actions are available on this page. If your chassis is configured as a Group
Lead, the Group Health page is displayed after login. For additional
information, see "Using Chassis Group" on page 107.
The Chassis Health page displays a live graphical view of the chassis and its components, as well as the details of the components. Depending on the selected component, various actions or links to other pages are available. In addition, the latest events in the CMC Hardware Log are also displayed.
All information on the Chassis Health page is dynamically updated. This page contains two major sections: Chassis Component Summary at the top followed by the Recent CMC Hardware Log Events listing.
Using the CMC Web Interface
The Chassis Component Summary section (also entitled "Chassis Health" when the overall chassis information is shown) displays the graphics and their associated information. You can hide this entire section by clicking the Close icon.
The left half of the Chassis Component Summary section displays the graphics and Chassis Quick Links. The right half of this section displays information, links, and actions related to the selected component. Click the graphical representation of a component to select the component. The graphic is cast in blue after selection.
The Recent CMC Hardware Log Events list displays the latest 10 events from this log. The content of this section is dynamically updated and presented with the latest event at the top of the list. For more information on
CMC Hardware Log entries, see "Viewing the Event Logs" on page 398.
Using Chassis Group
CMC enables you to monitor multiple chassis from a single lead chassis.
When a Chassis Group is enabled, CMC in the lead chassis generates a graphical display of the status of the lead chassis and all member chassis within the Chassis Group.
Chassis Group Features
The Chassis Group GUI page displays images portraying the front and back of each chassis, a set for the leader and a set for each member.
Health concerns for the leader and members of a group are recognized by red or yellow overlays and an X or an !
on the component with the symptoms.
Details are visible below the chassis image when you click the chassis image or the Details button.
A Chassis Group may contain a maximum of eight members. Also, a leader or member can only participate in one group. You cannot join a chassis, either leader or member, that is part of a group to another group. You can delete the chassis from a group and add it later to a different group.
Using the CMC Web Interface 107
Setting up a Chassis Group
The Chassis Group is set up with the GUI:
1 Log in with administrator privileges to the chassis planned as the leader.
2 Click Setup ï‚® Group Administration .
The Chassis Group page is displayed.
3 In the Chassis Group page, under Role , select Leader .
A field to add the group name is displayed.
4 Enter the Group name in the Group Name field, and then click Apply .
NOTE: The same rules that apply for a domain name apply to the group name.
When the Chassis Group is created the GUI automatically switches to the
Chassis Group GUI page. The System Tree indicates the group by the Group
Name and the lead chassis and the unpopulated member chassis appear in the System Tree.
After the Chassis Group is setup, you can add Members to the group:
1 Login with chassis administrator privileges to the leader chassis.
2 Select the Lead chassis in the tree.
3 Click Setup ï‚® Group Administration .
4 Under Group Management , enter the member’s IP address or DNS name in the Hostname/IP Address field.
5 Enter a user name with chassis administrator privileges on the member chassis, in the Username field.
6 Enter the corresponding password in the Password field.
7 Select the Apply button.
8
Repeat step 4 through step 7 to add a maximum of eight members.
The new members’ Chassis Names appear in the dialog box labeled
Members .
108 Using the CMC Web Interface
The status of the new member is displayed by selecting the Group in the tree.
Details are available by clicking on the chassis image or the details button.
NOTE: The credentials entered for a member are passed securely to the member chassis, to establish a trust relationship between the member and lead chassis. The credentials are not persisted on either chassis, and are never exchanged again after the initial trust relationship is established.
Removing a Member from the Leader
You can remove a member from the group from the lead chassis. To remove a member:
1 Login with chassis administrator privileges to the leader chassis.
2 Select the Lead chassis in the tree.
3 Click Setup ï‚® Group Administration .
4 From the Remove Members list, select the member’s name or names to be deleted, and then click Apply .
The lead chassis then communicates to the member or members, if more than one is selected, that it has been removed from the group. The member name is removed from the dialog box. The member chassis may not receive the message, if a network issue prevents contact between the leader and the member. In this case, disable the member from the member chassis to complete the removal. See the sub-section “Disabling an Individual Member at the Member Chassis” for the procedure.
Disbanding a Chassis Group
It is also possible to completely disband a group from the lead chassis. To do this:
1 Login with administrator privileges to the leader chassis.
2 Select the Lead chassis in the tree.
3 Click Setup ï‚® Group Administration .
4 In the Chassis Group page, under Role , select None, and then click Apply .
The lead chassis then communicates to all the members that they have been removed from the group. Finally the lead chassis discontinues its role. It can now be assigned as a member or a leader of another group.
Using the CMC Web Interface 109
The member chassis may not receive the message, if a network issue prevents contact between the leader and the member. In this case, disable the member from the member chassis to complete the removal. See the sub-section
“Disabling an Individual Member at the Member Chassis” for the procedure.
Disabling an Individual Member at the Member Chassis
Sometimes a member cannot be removed from a group by the lead chassis.
This can happen if network connectivity to the member is lost. A member can be removed from a group at the member chassis by:
1 Login with chassis administrator privileges to the member chassis.
2 Click Setup ï‚® Group Administration .
3 Select None, and then click Apply .
Chassis Component Summary
Chassis Graphics
The chassis is represented by front and back views (the upper and lower images, respectively). Servers and the LCD are shown in the front view and the remaining components are shown in the back view. Component selection is indicated by a blue cast and is controlled by clicking the image of the required component. When a component is present in the chassis, an icon of that component type is shown in the graphics in the position (slot) where the component has been installed. Empty positions are shown with a charcoalgray background. The component icon visually indicates the state of the component. The server icon is used in Table 5-1 as an example. Other components display icons that visually represent the physical component.
Icons for servers and IOMs span multiple slots when a double size component is installed. Hovering over a component displays a tooltip with additional information about that component.
110 Using the CMC Web Interface
Table 5-1. Server Icon States
Icon Description
Server is powered on and is operating normally.
Server is off.
Server is reporting a non-critical error.
Server is reporting a critical error.
Using the CMC Web Interface 111
Table 5-1. Server Icon States
Icon Description
No server is present.
The Chassis Quick Links are displayed below the Chassis Graphics.
Table 5-2. Chassis Quick Links
Field Description
Configure Users Navigate to Chassis Overview
Users
ï‚® User Authentication ï‚® Local
Network
Configuration
Navigate to Chassis Overview ï‚® Network ï‚® Network
Power
Configuration
Navigate to Chassis Overview ï‚® Power ï‚® Configuration
Firmware Update Navigate to Chassis Overview ï‚® Update ï‚® Firmware Update
Chassis Health
When the page first displays, the right side of the page contains the chassis level information and alerts. All active critical and non-critical alerts are displayed.
When a component is clicked, the chassis level information is replaced with a display of information for the selected component. To return to the chassis level information, click Return to Chassis Health in the upper right corner.
112 Using the CMC Web Interface
Table 5-3. Chassis Page Information
Field
Model
Firmware
Service Tag
Asset Tag
Input Power
Power Cap
Power Policy
Health
Description
Displays the model of the Chassis LCD panel.
Displays the firmware version of the active CMC.
Displays the service tag of the chassis. The service tag is a unique identifier that the manufacturer provides for support and maintenance.
Displays the asset tag for the chassis.
Amount of power that the chassis consumes presently.
User-assigned maximum Input Power to be consumed. As the chassis reaches this limit, servers begin to throttle to prevent a further rise in the required Input Power.
User-assigned preference for coordinating multiple Power
Supply Units.
Displays the overall health of the chassis power subsystem.
Selected Component Information
Information for the selected component is displayed in three independent sections:
• Health and Performance and Properties
The Active Critical and Non-Critical events as shown by the hardware logs are displayed here, if there are any. Performance data which vary with time are also shown here.
• Properties
Component properties which do not vary with time or change only infrequently are displayed here.
• Quick Links
The Quick Links section provides a convenient means of navigation to the most frequently accessed pages, and also the most frequently performed actions. Only links applicable to the selected component are displayed in this section.
Using the CMC Web Interface 113
Table 5-4. Health and Performance Information - Servers
Item Description
Power State
On/Off state of the server. See Table 5-23 for details on the
various types of power states.
Health Displays the text equivalent of the health icon.
Power Consumption Amount of power that the server consumes at present.
Power Allocated
Temperature
Amount of power budgeted for the server.
Temperature read from the server temperature sensor.
Table 5-5. Server Properties
Item
Name
Model
Service Tag
OS
Host Name iDRAC
BIOS
CPLD
Description
User-assigned slot name.
Server model, for example "PowerEdge M600" or "PowerEdge
M605".
The service tag of the server. The service tag is a unique identifier that the manufacturer provides for support and maintenance. If the server is absent, this field is empty.
Operating system on the server.
Name of the server as established by the operating system.
Version of iDRAC firmware on the server.
Server BIOS version.
Version number of Complex Programmable Logic Device
(CPLD) of the server.
114 Using the CMC Web Interface
Table 5-6. Quick Links - Servers
Item
Server Status
Description
Navigate to Server Overview
Status
ï‚® < selected server > ï‚® Properties ï‚®
Launch Remote
Console
Launch iDRAC
GUI
Invokes a Keyboard-Video-Mouse (KVM) session on the server if the server supports this operation.
Invokes an iDRAC management console for the server.
Power On Server Apply power to a server that is in the "Off" state.
Power Off Server Remove power from a server that is in the "On" state.
Remote File
Share
Navigate to Server Overview ï‚® Setup ï‚® Remote File Share
Deploy iDRAC
Network
Navigate to Server Overview ï‚® Setup ï‚® iDRAC (Deploy iDRAC)
Table 5-7. IOM Health and Performance
Item
Power State
Role
Description
Displays the power status of the I/O module: On, Off, or
Unknown (Absent).
Displays the I/O Module stacking membership while linking I/O modules together. Member indicates that the module is part of a stack set. Master indicates that the module is a primary access point.
Table 5-8. IOM Properties
Item
Model
Service Tag
Description
Displays the I/O module product name.
Displays the service tag of the I/O module. The service tag is a unique identifier provided by Dell for support and maintenance.
Using the CMC Web Interface 115
Table 5-9. Quick Links - I/O Modules
Item
IOM Status
Launch IOM
GUI
Description
Navigate to I/O Modules
Status
ï‚® < Selected IOM > ï‚® Properties ï‚®
If the Launch IOM GUI link is present for a particular I/O module, clicking it launches the IOM management console for that I/O module in a new browser window or tab.
Table 5-10. Active CMC Health and Performance
Item
Redundancy Mode
MAC Address
IPv4
IPv6
Description
Displays failover readiness of the standby CMC. If CMC firmware does not match, or CMC is not cabled properly to the management network, redundancy appears as not available
Displays the MAC address for the CMC Network Interface
Card (NIC). The MAC address is a unique identifier for the CMC over the network.
Displays the current IPv4 address for the CMC Network
Interface.
Displays the first IPv6 address for the CMC Network
Interface.
Table 5-11. CMC Properties
Item
Firmware
Standby Firmware
Last Updated
Hardware
Description
Displays the firmware version of the active CMC.
Displays the firmware version installed on the standby
CMC. If you have not installed a second CMC, this field is displayed NA.
Displays when the firmware was last updated. If no updates have occurred, this field is displayed as NA.
Displays the hardware version of the active CMC.
116 Using the CMC Web Interface
Table 5-12. Quick Links - CMC
Item Description
CMC Status
Networking
Navigate to Chassis Controller ï‚® Properties ï‚® Status
Navigate to Chassis Overview ï‚® Network ï‚® Network
Firmware Update Navigate to Chassis Overview ï‚® Update ï‚® Firmware Update
Table 5-13. iKVM Health and Performance
Item
OSCAR Console
Description
Displays whether the rear panel VGA connector is enabled
(Yes or No) for access to CMC.
Table 5-14. iKVM Properties
Item
Name
Part Number
Firmware
Hardware
Description
Displays the name of the iKVM.
Displays the part number for the iKVM. The part number is a unique identifier provided by the vendor. Part number naming conventions differ from vendor to vendor.
Displays the firmware version of the iKVM.
Displays the hardware version of the iKVM.
Table 5-15. Quick Links - iKVM
Item Description iKVM Status Navigate to iKVM ï‚® Properties ï‚® Status
Firmware Update Navigate to Chassis Overview ï‚® Update ï‚® Firmware Update
Table 5-16. Fan Health and Performance
Item
Speed
Description
Displays the speed of the fan in revolutions per minute
(RPM).
Using the CMC Web Interface 117
Table 5-17. Fan Properties
Item
Lower Critical
Threshold
Upper Critical
Threshold
Description
Speed below which the fan is considered to have failed.
Speed above which the fan is considered to have failed.
Table 5-18. Quick Links - Fan
Item
Fan Status
Description
Navigate to Fans ï‚® Properties ï‚® Status
Table 5-19. PSU Health and Performance
Item
Power Status
Description
Displays the power state of the power supplies (one of the following): Initializing, Online, Standby, In Diagnostics,
Failed, Updating, Offline, or Unknown.
Table 5-20. PSU Properties
Item
Capacity
Description
Displays the capacity of the power supply (in Watts).
Table 5-21. Quick Links - PSU
Item
Power Supply
Status
Power
Consumption
System Budget
Description
Navigate to Power Supplies ï‚®ï€ Properties ï‚® Status
Navigate to Chassis Overview
Consumption
Navigate to Chassis Overview
ï‚® Power ï‚® Power
ï‚® Power ï‚® Budget Status
118 Using the CMC Web Interface
Table 5-22. LCD Health and Performance
Item
LCD Health
Chassis Health
Description
Displays the presence and health of the LCD panel.
Displays the text description of Chassis Health.
There are no Quick Links for the LCD.
Monitoring System Health Status
Viewing Chassis and Component Summaries
CMC displays a graphical representation of the chassis on the Chassis Health page that provides a visual overview of installed component status. The
Chassis Health page is dynamically updated, and the component subgraphic overlays and text hints are automatically changed to reflect the current state.
Figure 5-1. Example of Chassis Graphics in the Web Interface
Using the CMC Web Interface 119
The Chassis Health page provides an overall health status for the chassis, active and standby CMCs, sever modules, IO Modules (IOMs), fans, iKVM, power supplies (PSUs), and LCD assembly. More detailed information for each component is displayed by clicking on that component. For instructions
on viewing chassis and components summaries, see "Viewing Chassis
Viewing Power Budget Status
The Power Budget Status page displays the power budget status for the chassis, servers, and chassis power supply units (PSUs).
For instructions on viewing power budget status, see "Viewing Power
Consumption Status" on page 311. For more information about CMC power
management, see "Power Management" on page 289.
Viewing Server Model Name and Service Tag
The Model Name and Service Tag of each server can be obtained instantly using the following steps:
• Expanding Servers in the System tree. All the servers (1-16) appear in the expanded Servers list. A slot without a server has its name grayed out.
• Using the cursor to hover over the slot name or slot number of a server; a tool tip is displayed with the server’s model name and service tag (if available).
Viewing the Health Status of All Servers
You can view the health status for all servers from the Chassis Graphics section on the Chassis Health page or the Servers Status page.
The Chassis Graphics provides a graphical overview of all servers installed in the chassis.
120 Using the CMC Web Interface
To view health status for all servers using Chassis Graphics:
1 Log in to the CMC Web interface.
The Chassis Health page is displayed. The left section of Chassis
Graphics depicts the front view of the chassis and contains the health status of all servers. Server health status is indicated by the overlay of the server subgraphic:
• No overlay - server is present, powered on and communicating with
CMC; there is no indication of an adverse condition.
• Amber caution sign - indicates that only warning alerts have been issued and that corrective action must be taken.
• Red X - indicates at least one failure condition is present. This means that CMC can still communicate with the component and the health status reported is critical.
• Grayed out - indicates that the component is present and not powered on. It is not communicating with CMC and there is no indication of an adverse condition.
The Servers Status page provides overviews of the servers in the chassis. To view health status for all servers using the Servers Status page:
1 Log in to the CMC Web interface.
2 Select Server Overview in the system tree. The Servers Status page appears.
Table 5-23. All Servers Status Information
Item
Slot
Name
Model
Description
Displays the location of the server. The slot number is a sequential number that identifies the server by its location within the chassis.
Displays the name of the server, which by default is identified by its slot name (SLOT-01 to SLOT-16).
NOTE: You can change the default server name. For instructions, see
"Editing Slot Names" on page 124.
Displays the server's model name. If this field is blank, the server is not present. If this field displays Extension of # (where the value of # is 1-8), the number # is the main slot of a multi-slot server.
Using the CMC Web Interface 121
Table 5-23. All Servers Status Information (continued)
Item
Health
Launch
Remote
Console
Description
OK
Informational Displays information about the server when no change in health status (OK, Warning,
Critical) has occurred.
Warning
Displays that the server is present and communicating with CMC. In the event of a communication failure between CMC and the server, CMC cannot obtain or display health status for the server.
Displays that only warning alerts have been issued, and corrective action must be taken.
If corrective actions are not taken, then critical failures that can affect the integrity of the server may occur.
Critical
No Value
Displays that at least one Failure alert has been issued. Critical status represents a system failure on the server, and corrective action must be taken immediately.
When the server is absent from the slot, health information is not provided.
Click to launch a Keyboard-Video-Mouse (KVM) session on the server in a new browser window or tab. This icon is only displayed for a server where all of the following conditions are met:
• Server is PowerEdge M610, M610X, M710, M710HD, or M910.
• The chassis power is on.
• The LAN interface on the server is enabled.
• The iDRAC version is 2.20 or later.
This feature functions correctly only if the following conditions are met:
• The host system is installed with JRE (Java Runtime Environment)
6 Update 16 or later.
• The browser on host system allows pop-up windows
(pop-up blocking is disabled).
122 Using the CMC Web Interface
Table 5-23. All Servers Status Information (continued)
Item Description
Launch iDRAC GUI
Left click the button to launch the iDRAC management console for a server in a new browser window or tab. This icon is only displayed for a server where all of the following conditions are met:
• The server is present.
• The chassis power is on.
• The LAN interface on the server is enabled.
This feature functions correctly only if the following condition is met:
• The browser on host system allows pop-up windows
(pop-up blocking is disabled).
NOTE: If the server is removed from the chassis, the IP address of iDRAC is changed, or the network connection on iDRAC experiences any problems, then clicking the Launch iDRAC GUI icon may display an error page on the iDRAC LAN interface.
Power State Displays the power status of the server:
• N/A - CMC has not yet determined the power state of the server.
• Off - Either the server is off or the chassis is off.
• On - Both chassis and server are on.
• Powering On - Temporary state between Off and On. When the action completes successfully, the Power State is On ..
• Powering Off - Temporary state between On and Off. When the action completes successfully, the Power State is Off .
Service Tag Displays the service tag for the server. The service tag is a unique identifier provided by the manufacturer for support and maintenance. If the server is absent, this field is empty.
For information on how to launch the iDRAC management console and
single sign-on policies, see "Launching iDRAC using Single Sign-On" on page 203.
Using the CMC Web Interface 123
124
Editing Slot Names
The Slot Names page allows you to update slot names in the chassis. Slot names are used to identify individual servers. When choosing slot names, the following rules apply:
• Names may contain a maximum of 15 non-extended ASCII characters
(ASCII codes 32 through 126).
• Slot names must be unique within the chassis. No two slots may have the same name.
• Strings are not case-sensitive. Server-1 , server-1 , and SERVER-1 are equivalent names.
• Slot names must not begin with the following strings:
• Switch-
• Fan-
• PS-
• KVM
• DRAC-
• MC-
• Chassis
• Housing-Left
• Housing-Right
• Housing-Center
• The strings Server-1 through Server-16 may be used, but only for the corresponding slot. For example, Server-3 is a valid name for slot 3, but not for slot 4. Note that Server-03 is a valid name for any slot.
NOTE: To change a slot name, you must have Chassis Configuration Administrator privilege.
NOTE: The slot name setting in the Web interface resides on CMC only. If a server is removed from the chassis, the slot name setting does not remain with the server.
NOTE: The slot name setting does not extend to the optional iKVM. The slot name information is available through the iKVM FRU.
NOTE: The slot name setting in the CMC Web interface always overrides any change you make to the display name in the iDRAC interface.
Using the CMC Web Interface
To edit a slot name:
1 Log in to the CMC Web interface.
2 Select Server Overview in the Chassis menu in the system tree.
3 Click Setup ï‚® Slot Names . The Slot Names page displays.
4 Type the updated or new name for a slot in the Slot Name field. Repeat this action for each slot you want to rename.
5 Click Apply .
6 To restore the default slot name ( SLOT-01 to SLOT-16 , based on the server's slot position) to the server, press Restore Default Value .
Using Server’s Host Name as the Slot Name
The Slot Names page allows to override the static slot names with the server’s
Host Name (or system name), if it is available. This requires the OMSA agent to be installed on the server. See the Dell OpenManage Server Administrator
User's Guide for more details on the OMSA agent.
To use server’s host name as slot name:
1 Log in to the CMC Web interface.
2 Select Server Overview in the Chassis menu from the system tree.
3 Click Setup ï‚® Slot Names . The Slot Names page displays.
4 Select the Use Host Name for the Slot Name check box.
5 Click Apply .
Setting the First Boot Device for Servers
The First Boot Device page allows you to specify the CMC first boot device for each server. This may not be the actual first boot device for the server or even represent a device present in that server; instead it represents a device sent by CMC to the server and used as its first boot device in regard to that server.
You can set the default boot device and you can also set a one-time boot device so that you can boot a special image to perform tasks such as running diagnostics or reinstalling an operating system.
The boot device that you specify must exist and contain bootable media.
Using the CMC Web Interface 125
126
Table 5-24. Boot Devices
Boot Device
PXE
Hard Drive
Local CD/DVD
Virtual Floppy
Virtual CD/DVD iSCSI
Local SD Card
Floppy
Description
Boot from a Preboot Execution Environment (PXE) protocol on the network interface card.
Boot from the hard drive on the server.
Boot from a CD/DVD drive on the server.
Boot from the virtual floppy drive. The floppy drive (or a floppy disk image) is on another computer on the management network, and is attached using the iDRAC GUI console viewer.
Boot from a virtual CD/DVD drive or CD/DVD ISO image.
The optical drive or ISO image file is located on another computer or disk available on the management network and is attached using the iDRAC GUI console viewer.
Boot from an Internet Small Computer System Interface
(iSCSI) device.
Boot from the local SD (Secure Digital) card - for the
M610/M710/M805/M905 systems only.
Boot from a floppy disk in the local floppy disk drive.
NOTE: To set the first boot device for servers, you must have Server Administrator privileges or Chassis Configuration Administrator privileges and iDRAC login privileges.
To set the first boot device for some or all servers in the chassis:
1 Log in to the CMC Web interface.
2 Click Server Overview in the system tree and then click Setup ï‚® First
Boot Device.
A list of servers is displayed as one per row.
3 Select the boot device you want to use for each server from the list box.
4 If you want the server to boot from the selected device every time it boots, clear the Boot Once check box for the server.
If you want the server to boot from the selected device only on the next boot cycle, select the Boot Once check box for the server.
5 Click Apply .
Using the CMC Web Interface
Viewing the Health Status of an Individual Server
The health status for an individual server can be viewed in two ways: from the Chassis Graphics section on the Chassis Health page or the
Server Status page.
The Chassis Health page provides a graphical overview of an individual server installed in the chassis.
To view health status for individual servers using Chassis Graphics:
1 Log in to the CMC Web interface.
The Chassis Health page is displayed. The top section of Chassis
Graphics depicts the front view of the chassis and contains the health status for individual servers. Server health status is indicated by the overlay of the server subgraphic:
• No overlay - indicates that the server is present, powered on and communicating with the CMC; there is no indication of an adverse condition.
• Amber caution sign - indicates that only warning alerts have been issued and that corrective action must be taken.
• Red X - indicates at least one failure condition is present. This means that CMC can still communicate with the component and that the health status is reported as critical.
• Grayed out - indicates that the component is present and not powered on. It is not communicating with CMC and there is no indication of an adverse condition.
2 Move the cursor to hover over an individual server subgraphic.
A corresponding text hint or screen tip is displayed. The text hint provides additional information on that server.
3 Click the server subgraphic to select that server’s information and display
Quick Links on the right of the chassis graphics.
Using the CMC Web Interface 127
The Server Status page (separate from the Servers Status page) provides an overview of the server and a launch point to the Web interface for the
Integrated Dell Remote Access Controller (iDRAC), which is the firmware used to manage the server.
NOTE: To use the iDRAC user interface, you must have an iDRAC user name and password. For more information about iDRAC and the using the iDRAC Web interface, see the Integrated Dell Remote Access Controller Firmware User’s Guide .
To view the health status of an individual server:
1 Log in to the CMC Web interface.
2 Expand Server Overview in the system tree. All of the servers (1–16) appear in the expanded Servers list.
3 Click the server (slot) you want to view. The Server Status page displays.
You can also view the server status page by clicking the status link in the server Quick Links on the right side of the page.
Table 5-25. Individual Server Status - Properties
Item
Slot
Slot Name
Present
Description
Displays the slot occupied by the server on the chassis.
Slot numbers are sequential IDs, from 1 through 16 (there are
16 slots available on the chassis), that help identify the location of the server in the chassis.
Displays the name of the slot where the server resides.
Displays whether the server is present in the slot (Yes or No). When the server is absent, the health, power state, and service tag information of the server is unknown (not displayed).
128 Using the CMC Web Interface
Table 5-25. Individual Server Status - Properties (continued)
Item Description
Health OK
Informational Displays information about the server when no change in health status (OK, Warning,
Critical) has occurred.
Warning
Displays that the server is present and communicating with CMC. In the event of a communication failure between CMC and the server, CMC cannot obtain or display health status for the server.
Displays that only warning alerts have been issued, and corrective action must be taken.
If corrective actions are not taken, then critical failures that can affect the integrity of the server may occur.
Critical Displays that at least one Failure alert has been issued. Critical status represents a system failure on the server, and corrective action must be taken immediately.
Server Model
No Value When the server is absent from the slot, health information is not provided.
Displays the model of the server in the chassis.
Examples: PowerEdge M600 , PowerEdge M605 .
Service Tag Displays the service tag for the server. The service tag a unique identifier provided by the manufacturer for support and maintenance. If the server is absent, this field is empty. iDRAC
Firmware
Displays the iDRAC version currently installed on the server.
CPLD Version Displays the version number of Complex Programmable Logic
Device (CPLD) of the server.
BIOS version Displays the BIOS version on the server.
Operating
System
Displays the operating system on the server.
Using the CMC Web Interface 129
Table 5-26. Individual Server Status - iDRAC System Event Log
Item
Severity
Date/Time
Description
Description
OK Indicates a normal event that does not require corrective actions.
Informational Indicates an informational entry on an event in which the Severity status has not changed.
Unknown Indicates an unknown/uncategorized event.
Warning
Critical
Indicates a non-critical event for which corrective actions must be taken soon to avoid system failures.
Indicates a critical event requiring immediate corrective actions to avoid system failures.
Displays the exact date and time the event occurred
(for example, Wed May 02 16:26:55 2007).
Provides a brief description of the event.
Table 5-27. Individual Server Status - iDRAC Network Settings
Item Description
LAN Enabled Indicates if the LAN channel is Enabled ( Yes ) or disabled ( No ).
130 Using the CMC Web Interface
Table 5-28. Individual Server Status - IPv4 iDRAC Network Settings
Item Description
Enabled Indicates if the IPv4 protocol is used on the LAN (Yes). If the server does not support IPv6, the IPv4 protocol is always enabled and this setting is not displayed.
DHCP Enabled Indicates whether Dynamic Host Configuration Protocol (DHCP) is enabled ( Yes ) or disabled ( No ).
If this option is enabled ( Yes ), the server retrieves IP configuration
(IP address, subnet mask, and gateway) automatically from a
DHCP server on your network. The server always has a unique IP
Address allotted over your network.
IPMI over LAN
Enabled
Indicates if the IPMI LAN channel is Enabled ( Yes ) or disabled ( No ).
IP Address Specifies the IP address for the iDRAC network interface.
Subnet Mask Specifies the subnet mask for the iDRAC network interface.
Gateway Specifies the gateway for the iDRAC network interface.
Table 5-29. Individual Server Status - IPv6 iDRAC Network Settings
Item Description
Enabled
Autoconfiguration
Enabled
Indicates if Autoconfiguration for IPv6 is enabled (Yes).
If Autoconfiguration is enabled, the server retrieves IPv6 configuration ( IPv6 address, Prefix Length , and IPv6 Gateway ) automatically from an IPv6 router on your network. The server always has a unique IPv6 address over your network, and may be given up to 16 IPv6 addresses.
Link Local
Address
Gateway
IPv6 Address
Indicates if the IPv6 protocol is used on the LAN (Yes).
IPv6 address assigned to CMC based upon the MAC address of
CMC.
Displays the IPv6 gateway for the iDRAC network interface.
Displays an IPv6 address for the iDRAC network interface.
There may be up to 16 of these addresses. The prefix length, if nonzero, is given after a forward slash ("/").
Using the CMC Web Interface 131
Table 5-30. Individual Server Status - WWN/MAC Address
Item Description
Slot
Location
Displays the slot(s) occupied by the server on the chassis.
Displays the location occupied by the Input/Output modules.
The six locations are identified by a combination of the group name (A, B, or C) and slot number (1 or 2). Location names are:
A1, A2, B1, B2, C1, or C2.
Displays the type of the I/O fabric. Fabric
Server-Assigned Displays the server-assigned WWN/MAC addresses embedded in the controller's hardware. WWN/MAC addresses showing N/A indicate that an interface for the specified fabric is not installed.
Chassis-
Assigned
Displays the chassis-assigned WWN/MAC addresses used for the particular slot. WWN/MAC addresses showing N/A indicate that the FlexAddress feature is not installed.
NOTE: A green check mark in the Server-Assigned and
Chassis-Assigned columns indicates the type of active addresses.
NOTE: When FlexAddress is enabled, slots without servers installed display the Chassis-Assigned MAC/WWN assignment for the embedded Ethernet controllers (Fabric A). The Chassis-Assigned addresses for fabrics B and C display N/A, unless these fabrics are in use on servers in populated slots; it is assumed that the same fabric types are deployed in the unpopulated slots.
For information on how to launch the iDRAC management console and
single sign-on policies, see "Launching iDRAC using Single Sign-On" on page 203.
Viewing the Health Status of IOMs
The health status for the IOMs can be viewed in two ways: from the Chassis
Component Summary section on the Chassis Health page or the I/O
Modules Status page. The Chassis Health page provides a graphical overview of the IOMs installed in the chassis.
132 Using the CMC Web Interface
To view health status of the IOMs using Chassis Graphics:
1 Log in to the CMC Web interface.
The Chassis Health page is displayed. The lower section of Chassis
Graphics depicts the rear view of the chassis and contains the health status for the IOMs. IOM health status is indicated by the overlay of the IOM subgraphic:
• No overlay - IOM is present, powered on and communicating with
CMC; there is no indication of an adverse condition.
• Amber caution sign - indicates that only warning alerts have been issued and that corrective action must be taken.
• Red X - indicates at least one failure condition is present. This means that CMC can still communicate with the component and that the health status reported is critical.
• Grayed Out - indicates that the IOM is present and not powered on. It is not communicating with CMC and there is no indication of an adverse condition.
2 Use the cursor to hover over an individual IOM subgraphic.
A text hint or screen tip is displayed. The text hint provides additional information on that IOM.
3 Clicking the IOM subgraphic selects that IOM’s information and Quick
Links for display to the right of the chassis graphics.
The I/O Modules Status page provides overviews of all IOMs associated with the chassis. For instructions on viewing IOM health through the
Web interface or RACADM, see "Monitoring IOM Health" on page 365.
Viewing the Health Status of the Fans
NOTE: During updates of CMC or iDRAC firmware on a server, some or all of the fan units in the chassis spin at 100%. This is normal.
The health status of the fans can be viewed in two ways: from the Chassis
Component Summary section on the Chassis Health page or the Fans Status page. The Chassis Health page provides a graphical overview of all fans installed in the chassis.
Using the CMC Web Interface 133
To view health status for all fans using Chassis Graphics :
1 Log in to the CMC Web interface.
The Chassis Health page is displayed. The lower section of Chassis
Graphics depicts the rear view of the chassis and contains the health status of all fans. Fan health status is indicated by the overlay of the fan subgraphic:
• No overlay - the fan is present and running; there is no indication of an adverse condition.
• Amber caution sign - indicates that only warning alerts have been issued and that corrective action must be taken.
• Red X - indicates at least one failure condition is present. This means that the health status is reported as critical.
• Grayed Out - indicates that the fan is present and not powered on.
There is no indication of an adverse condition.
2 Use the cursor to hover over the an individual fan subgraphic.
A text hint or a screen tip is displayed. The text hint provides additional information on that fan.
3 Clicking the fan subgraphic selects that fan's information and Quick Links for display to the right of the chassis graphics.
The Fans Status page provides the status and speed measurements in revolutions per minute, or RPMs, of the fans in the chassis. There can be one or more fans.
CMC, which controls fan speeds, automatically increases or decreases fan speeds based on system wide events. CMC generates an alert and increases the fan speeds when the following events occur:
• CMC ambient temperature threshold is exceeded.
• A fan fails.
• A fan is removed from the chassis.
To view the health status of the fan units:
1 Log in to the CMC Web interface.
2 Select Fans in the system tree. The Fans Status page displays.
134 Using the CMC Web Interface
You can also view the Fan Status page by clicking the status link in the fan information Quick Links on the right side of the page.
Table 5-31. Fans Health Status Information
Item
Name
Present
Health
Speed
Description
Displays the fan name in the format FAN -n , where n is the fan number.
Indicates whether the fan unit is present ( Yes or No ).
OK Indicates that the fan unit is present and communicating with CMC. In the event of a communication failure between CMC and the fan unit, CMC cannot obtain or display health status for the fan unit.
Critical
Unknown
Indicates that at least one Failure alert has been issued. Critical status represents a system failure on the fan unit, and corrective action must be taken immediately to prevent overheating and system shutdown.
Displayed when the chassis is first powered on.
In the event of a communication failure between CMC and the fan unit, CMC cannot obtain or display health status for the fan unit.
Indicates the speed of the fan in RPM.
Viewing the iKVM Status
The local access KVM module for your Dell M1000e server chassis is called the Avocent Integrated KVM Switch Module, or iKVM.
The health status of the iKVM associated with the chassis can be viewed on the Chassis Health page.
Using the CMC Web Interface 135
To view health status for the iKVM using Chassis Graphics :
1 Log in to the CMC Web interface.
The Chassis Health page is displayed. The lower section of Chassis
Graphics depicts the rear view of the chassis and contains the health status of the iKVM. iKVM health status is indicated by the overlay of the iKVM subgraphic:
• No overlay - iKVM is present, powered on and communicating with
CMC; there is no indication of an adverse condition.
• Amber caution sign - indicates that only warning alerts have been issued and that corrective action must be taken.
• Red X - indicates at least one failure condition is present. This means that CMC can still communicate with the iKVM and that the health status reported is critical.
• Grayed Out - indicates that the iKVM is present and not powered on.
It is not communicating with CMC and there is no indication of an adverse condition.
2 Use the cursor to hover over the iKVM subgraphic.
A text hint or a screen tip is displayed. The text hint provides additional information on that iKVM.
3 Clicking the iKVM subgraphic selects the iKVM's information and Quick
Links for display to the right of the chassis graphics.
You can also view the iKVM Status page by clicking the status link in the iKVM Quick Links on the right side of the chassis graphics.
For additional instructions on viewing iKVM status and setting properties for the iKVM, see:
• "Viewing the iKVM Status and Properties" on page 352
• "Enabling or Disabling the Front Panel" on page 351
• "Enabling the Dell CMC Console Through iKVM" on page 352
• "Updating the iKVM Firmware" on page 354
For more information about iKVM, see "Using the iKVM Module" on page 333.
136 Using the CMC Web Interface
Viewing the Health Status of the PSUs
The health status of the PSUs associated with the chassis can be viewed in two ways: from the Chassis Component Summary section on the Chassis
Health page or the Power Supply Status page. The Chassis Health page provides a graphical overview of all PSUs installed in the chassis.
To view health status for all PSUs using Chassis Graphics :
1 Log in to the CMC Web interface.
The Chassis Health page is displayed. The lower section of Chassis
Graphics depicts the rear view of the chassis and contains the health status of all PSUs. PSU health status is indicated by the overlay of the PSU subgraphic:
• No overlay - PSU is present, powered on and communicating with
CMC; there is no indication of an adverse condition.
• Amber caution sign - indicates that only warning alerts have been issued and that corrective action must be taken.
• Red X - indicates at least one failure condition is present. This means that CMC can still communicate with the PSU and that the health status is reported as critical.
• Grayed Out - indicates that the PSU is present and not powered on. It is not communicating with CMC and there is no indication of an adverse condition.
2 Use the cursor to hover over an individual PSU subgraphic and a corresponding text hint or screen tip is displayed. The text hint provides additional information on that PSU.
3 Clicking on the PSU subgraphic selects that PSU's information and Quick
Links for display to the right of the chassis graphics.
The Power Supply Status page displays the status and readings of the PSUs associated with the chassis. For more information about CMC power
management, see "Power Management" on page 289.
To view the health status of the PSU s:
1 Log in to the CMC Web interface.
2 Select Power Supplies in the system tree. The Power Supply Status page displays.
Using the CMC Web Interface 137
138
You can also view the PSU Status page by clicking the status link in the PSU
Quick Links on the right side of the chassis graphics.
Table 5-32. Power Supply Health Status Information
Item
Name
Description
Present
Health
Power Status
Capacity
OK
Critical
Unknown
Displays the name of the PSU: PS-n , where n is the power supply number.
Indicates whether the power supply is present
( Yes or No ).
Indicates that the PSU is present and communicating with CMC. Indicates that the health of the PSU is OK. In the event of a communication failure between CMC and the fan unit, CMC cannot obtain or display health status for the PSU.
Indicates that the PSU has a failure and the health is critical. Corrective action must be taken immediately. Failure to do so may cause the component to shutdown due to power loss.
Displayed with the chassis is first powered on.
In the event of a communication failure between CMC and the PSU, CMC cannot obtain or display health status for the PSU.
Indicates the power state of the PSU: Online ,
Off , or Slot Empty .
Displays the power capacity in watts.
Table 5-33. System Power Status
Item
Overall Power Health
System Power Status
Description
Displays the health status ( OK, Non-Critical,
Critical, Non-Recoverable, Other, Unknown ) of the power management for the entire chassis.
Displays the power status (On, Off, Powering On,
Powering Off) of the chassis.
Using the CMC Web Interface
Table 5-33. System Power Status (continued)
Item
Redundancy
Description
Displays the power supply redundancy status. Values include:
No : Power Supplies are not redundant.
Yes : Full Redundancy in effect.
Viewing Status of the Temperature Sensors
The Temperature Sensors Status page displays the status and readings of the temperature probes on the entire chassis (chassis and servers).
NOTE: The temperature probes value cannot be edited. Any change beyond the threshold generates an alert that causes the fan speed to vary. For example, if the
CMC ambient temperature probe exceeds threshold, the speed of the fans on the chassis increases.
To view the health status of the temperature probes:
1 Log in to the CMC Web interface.
2 Select Temperature Sensors in the system tree. The Temperature Sensors
Status page displays.
Table 5-34. Temperature Sensors Health Status Information
Item
ID
Name
Present
Health
Description
Displays the location of the temperature probe.
Displays the name of each temperature probe for the chassis and servers.
Indicates whether the module is present (Yes) or absent (No) in the chassis.
OK Indicates that the module is present and communicating with CMC. In the event of a communication failure between CMC and the server, CMC cannot obtain or display the health status for the server.
Using the CMC Web Interface 139
140
Table 5-34. Temperature Sensors Health Status Information (continued)
Item
Reading
Threshold
Maximum
Description
Warning
Severe
Indicates that only warning alerts have been issued, and corrective action must be taken. If corrective actions are not taken, then critical or severe failures that can affect the integrity of the module may occur.
Indicates that one failure alert has been issued.
Severe status represents a system failure on the module and corrective action must be taken immediately.
Unknown Indicates that communication with the module has not been established. This is usually because the chassis is off or the chassis has not completed initialization.
Displays the current temperature in degrees Centigrade and
Fahrenheit.
Displays the highest temperature, in degrees Centigrade and
Fahrenheit, at which a Failure alert is issued.
Viewing the LCD Status
You can view the health status of the LCD using the chassis graphics associated with the chassis on the Chassis Health page.
To view the health status for the LCD:
1 Log in to the CMC Web interface.
The Chassis Health page is displayed. The top section of Chassis Graphics depicts the front view of the chassis. LCD health status is indicated by the overlay of the LCD subgraphic:
• No overlay - LCD is present, powered on, and communicating with
CMC. There is no adverse condition.
• Amber caution sign - warning alerts have been issued and corrective action must be taken.
• Red X - at least one failure condition is present. The health status is critical.
Using the CMC Web Interface
• Grayed Out - the LCD is present and not powered on. It is not communicating with CMC and there is no adverse condition.
2 Move the cursor over the LCD subgraphic. The corresponding text hint or screen tip, which provides additional information on the LCD is displayed.
3 Click the LCD subgraphic to select the LCD's information and display it to the right side of the chassis graphics.
Viewing World Wide Name/Media Access
Control (WWN/MAC) IDs
The WWN/MAC Summary page allows you to view the WWN configuration and MAC address of a slot in the chassis.
Fabric Configuration
The Fabric Configuration section displays the type of Input/Output fabric that is installed for Fabric A, Fabric B, and Fabric C. A green check mark indicates that the fabric is enabled for FlexAddress. The FlexAddress feature is used to deploy chassis assigned and slot persistent WWN/MAC addresses to various fabrics and slots within the chassis. This feature is enabled on a per fabric and per slot basis.
NOTE:
See "Using FlexAddress" on page 217 for more information on the
FlexAddress feature.
Using the CMC Web Interface 141
WWN/MAC Addresses
The WWN/MAC Address section displays the WWN/MAC information that is assigned to all servers, even if those server slots are currently empty.
Location displays the location of the slot occupied by the Input/Output modules. The six slots are identified by a combination of the group name
(A, B, or C) and slot number (1 or 2): slot names A1, A2, B1, B2, C1, or C2. iDRAC is the server's integrated management controller. Fabric displays the type of the I/O fabric. Server-Assigned displays the server-assigned
WWN/MAC addresses embedded in the controller's hardware.
Chassis-Assigned displays the chassis-assigned WWN/MAC addresses used for the particular slot. A green check mark in the Server-Assigned or in Chassis-Assigned columns indicates the type of active addresses.
Chassis-Assign addresses are assigned when FlexAddress is activated on the chassis, and represents the slot-persistent addresses. When Chassis-Assigned addresses are checked, those addresses are used even if one server is replaced with another server.
Configuring CMC Network Properties
NOTE: Network configuration changes can result in the loss of connectivity on current network login.
Setting Up Initial Access to CMC
Before you can begin configuring CMC, you must first configure the CMC network settings to allow the CMC to be managed remotely. This initial configuration assigns the TCP/IP networking parameters that enable access to CMC.
NOTE: You must have Chassis Configuration Administrator privilege to set up CMC network settings.
1 Log in to the Web interface.
2 Select Chassis Overview in the system tree.
142 Using the CMC Web Interface
3 Click the Network tab. The Network Configuration page appears.
4 Enable or disable DHCP for CMC by selecting or clearing the Use DHCP
(For CMC Network Interface IP Address) check box.
5 If you disabled DHCP, type the IP address, gateway, and subnet mask.
6 Click Apply Changes at the bottom of the page.
Configuring the Network LAN Settings
NOTE: You must have Chassis Configuration Administrator privilege to set up CMC network settings.
NOTE: The settings on the Network Configuration page, such as community string and SMTP server IP address, affect both CMC and the external settings of the chassis.
NOTE: If you have two CMCs (active and standby) on the chassis, and they are both connected to the network, the standby CMC automatically assumes the network settings in the event of failover of the active CMC.
To configure the Network LAN settings:
1 Log in to the Web interface.
2 Click the Network tab.
3
Configure the CMC network settings described in Table 5-35 through
4 Click Apply Changes .
To configure IP range and IP blocking settings, click the Advanced Settings
button (see "Configuring CMC Network Security Settings" on page 151.)
To refresh the contents of the Network Configuration page, click Refresh .
To print the contents of the Network Configuration page, click Print .
Using the CMC Web Interface 143
Table 5-35. Network Settings
Setting Description
CMC MAC Address
Enable CMC Network
Interface
Displays the chassis’ MAC address, which is a unique identifier for the chassis over the computer network.
Enables the Network Interface of CMC.
Default: Enabled. If this option is checked:
• CMC communicates with and is accessible over the computer network.
• The Web interface, CLI (remote RACADM), WSMAN,
Telnet, and SSH associated with CMC are available.
If this option is not checked:
• The CMC Network Interface cannot communicate over the network.
• Communication to the chassis through CMC is not available.
• The Web interface, CLI (remote RACADM), WSMAN,
Telnet, and SSH associated with the CMC are not available.
• The server iDRAC Web interface, local CLI,
I/O modules, and iKVM are still accessible.
• Network addresses for the iDRAC6 and CMC can be obtained, in this case, from the chassis' LCD.
NOTE: Access to the other network-accessible components in the chassis is not affected when the network on the chassis is disabled (or lost).
Register CMC on DNS This property registers the CMC name on the DNS Server.
Default : Unchecked (disabled) by default
NOTE: Some DNS Servers only register names of 31 characters or fewer. Make sure the designated name is within the DNS required limit.
144 Using the CMC Web Interface
Table 5-35. Network Settings (continued)
Setting Description
DNS CMC Name
Use DHCP for DNS
Domain Name
DNS Domain Name
Displays the CMC name only when Register CMC on
DNS is selected. The default CMC name is
CMC_service_tag , where service tag is the service tag of the chassis, for example: CMC-00002. The maximum number of characters is 63. The first character must be a letter (a-z,
A-Z), followed by an alphanumeric (a-z, A-Z, 0-9) or a hyphen (-) characters.
Uses the default DNS domain name. This check box is active only when Use DHCP (For CMC Network
Interface IP Address) is selected.
Default: Enabled
The default DNS Domain Name is a blank character.
This field can be edited only when the Use DHCP for
DNS Domain Name check box is selected.
Auto Negotiation (1 Gb) Determines whether CMC automatically sets the duplex mode and network speed by communicating with the nearest router or switch ( On ) or allows you to set the duplex mode and network speed manually ( Off ).
Default : On
If Auto Negotiation is On , CMC automatically communicates with the nearest router or switch and operates at 1 Gb speed.
If Auto Negotiation is Off , you must set the duplex mode and network speed manually.
Using the CMC Web Interface 145
Table 5-35. Network Settings (continued)
Setting
Network Speed
Duplex Mode
MTU
Description
Set the network speed to 100 Mbps or 10 Mbps to match your network environment.
NOTE: The Network Speed setting must match your network configuration for effective network throughput. Setting the
Network Speed lower than the speed of your network configuration increases bandwidth consumption and slows network communication. Determine whether your network supports the above network speeds and set it accordingly.
If your network configuration does not match any of these values, it is recommended that you use Auto Negotiation or refer to your network equipment manufacturer.
NOTE: To use 1000 Mb or 1 Gb speeds, select Auto
Negotiation.
Set the duplex mode to full or half to match your network environment.
Implications: If Auto Negotiation is turned On for one device but not the other, then the device using auto negotiation can determine the network speed of the other device, but not the duplex mode. In this case, duplex mode defaults to the half duplex setting during auto negotiation. such a duplex mismatch results in a slow network connection.
NOTE: The network speed and duplex mode settings are not available if Auto Negotiation is set to On.
Sets the size of the Maximum Transmission Unit (MTU), or the largest packet that can be passed through the interface.
Configuration range: 576 – 1500.
Default: 1500.
NOTE: IPv6 requires a minimum MTU of 1280. If IPv6 is enabled, and cfgNetTuningMtu is set to a lower value, the CMC uses an MTU of 1280.
146 Using the CMC Web Interface
Table 5-36. IPv4 Settings
Setting
Enable IPv4
DHCP Enable
Static IP Address
Static Subnet Mask
Description
Allow CMC to use the IPv4 protocol to communicate on the network. Clearing this box does not prevent IPv6 networking from occurring. Default: Checked (enabled)
Enables CMC to request and obtain an IP address from the IPv4 Dynamic Host Configuration Protocol (DHCP) server automatically. Default: Checked (enabled)
If this option is checked, CMC retrieves
IPv4 configuration (IP Address, subnet mask, and gateway) automatically from a DHCP server on your network. CMC always has a unique IP Address allotted over your network.
NOTE: When this feature is enabled, the Static IP Address,
Static Subnet Mask, and Static Gateway property fields
(located immediately following this option on the Network
Configuration page) are disabled, and any previously entered values for these properties are ignored.
If this option is not checked, you must manually type the
Static IP Address , Static Subnet Mask , and Static
Gateway in the text fields immediately following this option in the Network Configuration page.
Specifies the IPv4 address for the CMC Network Interface.
Specifies the static IPv4 subnet mask for the CMC
Network Interface.
Using the CMC Web Interface 147
Table 5-36. IPv4 Settings (continued)
Setting
Static Gateway
Use DHCP to Obtain
DNS Server Addresses
Description
Specifies the IPv4 gateway for the CMC Network
Interface.
NOTE: The Static IP Address, Static Subnet Mask, and
Static Gateway fields are active only if DHCP Enable (the property field preceding these fields) is disabled
(unchecked). In that case, you must manually type the Static
IP Address, Static Subnet Mask, and Static Gateway for
CMC to use over the network.
NOTE: The Static IP Address, Static Subnet Mask, and
Static Gateway fields apply only to the chassis device. They do not affect the other network-accessible components in the chassis solution, such as the server network, local access, I/O modules, and iKVM.
Obtains the primary and secondary DNS server addresses from the DHCP server instead of the static settings.
Default: Checked (enabled) by default
NOTE: If Use DHCP (For CMC Network Interface IP Address) is enabled, then enable the Use DHCP to Obtain DNS Server
Addresses property.
If this option is checked , CMC retrieves its
DNS IP address automatically from a DHCP server on your network.
NOTE: When this property is enabled, the Static Preferred
DNS Server and Static Alternate DNS Server property fields
(located immediately following this option on the Network
Configuration page) are inactivated, and any previously entered values for these properties are ignored.
If this option is not selected, CMC retrieves the DNS IP address from the Static Preferred DNS Server and Static
Alternate DNS Server. The addresses of these servers are specified in the text fields immediately following this option on the Network Configuration page.
148 Using the CMC Web Interface
Table 5-36. IPv4 Settings (continued)
Setting
Static Preferred DNS
Server
Static Alternate DNS
Server
Description
Specifies the static IP address for the preferred
DNS Server. The Static Preferred DNS Server is implemented only when Use DHCP to Obtain DNS
Server Addresses is disabled.
Specifies the static IP address for the alternate
DNS Server. The Static Alternate DNS Server is implemented only when Use DHCP to obtain
DNS Server addresses is disabled. If you do not have an alternate DNS Server, type an IP address of 0.0.0.0.
Using the CMC Web Interface 149
Table 5-37. IPv6 Settings
Setting Description
Enable IPv6
AutoConfiguration
Enable
Allows CMC to use the IPv6 protocol to communicate on the network. Unchecking this box does not prevent IPv4 networking from occurring. Default: Checked (enabled)
Allows CMC to use the IPv6 protocol to obtain IPv6 related address and gateway settings from an IPv6 router configured to provide this information. CMC then has a unique IPv6 address on your network.
Default: Checked (enabled)
NOTE: When this feature is enabled, the Static IPv6 Address,
Static Prefix Length, and Static Gateway property fields
(located immediately following this option on the Network
Configuration page) are disabled, and any previously entered values for these properties are ignored.
If this option is not checked, you must manually type the
Static IPv6 Address, Static Prefix Length, and Static
Gateway in the text fields located immediately following this option on the Network Configuration page.
Static IPv6 Address
Static Prefix Length Specifies the IPv6 prefix length for the CMC Network
Interface when Autoconfiguration is not enabled.
Static Gateway
Specifies the IPv6 address for the CMC Network Interface when Autoconfiguration is not enabled.
Specifies the static IPv6 gateway for the CMC Network
Interface when Autoconfiguration is not enabled.
NOTE: The Static IPv6 Address, Static Prefix Length, and
Static Gateway fields are active only if AutoConfiguration
Enable (the property field preceding these fields) is disabled
(unchecked). In that case, you must manually type the Static
IPv6 Address, Static Prefix Length, and Static Gateway for
CMC to use over the IPv6 network.
NOTE: The Static IPv6 Address, Static Prefix Length, and
Static Gateway fields apply only to the chassis device. They do not affect the other network-accessible components in the chassis solution, such as the server network, local access, I/O modules, and iKVM.
150 Using the CMC Web Interface
Table 5-37. IPv6 Settings (continued)
Setting
Static Preferred DNS
Server
Static Alternate DNS
Server
Description
Specifies the static IPv6 Address for the preferred DNS
Server. The entry for Static Preferred DNS Server is considered only when Use DHCP to Obtain DNS Server
Addresses is disabled or unchecked. There is an entry for this
Server in both IPv4 and IPv6 configuration areas.
Specifies the static IPv6 Address for the alternate DNS
Server. If you do not have an alternate DNS server, type an
IPv6 Address of "::". The entry for Static Alternate DNS
Server is considered only when Use DHCP to Obtain DNS
Server Addresses is disabled or unchecked. There is an entry for this server in both IPv4 and IPv6 configuration areas.
Configuring CMC Network Security Settings
NOTE: To perform the following steps, you must have Chassis Configuration
Administrator privilege.
1 Log in to the Web interface.
2 Click the Network tab.
The Network Configuration page displays.
3 Click the Advanced Settings button.
The Network Security page displays.
4 Configure the CMC network security settings.
settings on the Network Security page.
NOTE: The IP Range and IP Blocking settings are applicable to IPv4 only.
Table 5-38. Network Security Page Settings
Settings Description
IP Range Enabled Enables the IP Range checking feature, which defines a specific range of IP addresses that can access CMC.
IP Range Address Determines the base IP address for range checking.
Using the CMC Web Interface 151
152
Table 5-38. Network Security Page Settings (continued)
Settings
IP Range Mask
IP Blocking
Enabled
• IP Blocking Fail
Count
• IP Blocking Fail
Window
• IP Blocking
Penalty Time
Description
Defines a specific range of IP addresses that can access the CMC, a process called IP range checking.
IP range checking allows access to CMC only from clients or management stations whose IP addresses are within the user-specified range. All other logins are denied.
For example:
IP range mask: 255.255.255.0
(11111111.11111111.11111111.00000000)
IP range address:192.168.0.255
(11000000.10101000.00000000.11111111)
The resulting IP address range is any address that contains
192.168.0, that is, any address from 192.168.0.0 through
192.168.0.255.
Enables the IP address blocking feature, which limits the number of failed login attempts from a specific IP address for a pre-selected time span.
Sets the number of login failures attempted from an IP address before the login attempts are rejected from that address.
Determines the time span in seconds within which
IP Blocking Fail Count failures must occur to trigger the IP Block Penalty Time.
The time span in seconds within which login attempts from an
IP address with excessive failures are rejected.
NOTE: The IP Blocking Fail Count, IP Blocking Fail Window, and
IP Blocking Penalty Time fields are active only if the IP Blocking
Enabled check box (the property field preceding these fields) is checked (enabled). In that case, you must manually type
IP Blocking Fail Count, IP Blocking Fail Window, and IP Blocking
Penalty Time properties.
5 Click Apply to save your settings.
To refresh the contents of the Network Security page, click Refresh .
To print the contents of the Network Security page, click Print .
Using the CMC Web Interface
Configuring VLAN
VLANs are used to allow multiple virtual LANs to co-exist on the same physical network cable and to segregate the network traffic for security or load management purposes. When you enable the VLAN functionality, each network packet is assigned a VLAN tag.
1 Log in to the Web interface.
2 Click the Network tab ï‚®ï€ VLAN subtab.
The VLAN Tag Settings page displays. VLAN tags are chassis properties.
They remain with the chassis even when a component is removed.
3 Configure the CMC/iDRAC VLAN settings.
settings on the Network Security page.
Table 5-39. VLAN Tag Settings
Setting
Slot
Name
Enable
Priority
ID
Description
Displays the slot occupied by the server in the chassis.
Slots are sequential IDs, from 1 to 16 (for the 16 available slots in the chassis), that help identify the location of the server in the chassis.
Displays the name of the server in each slot.
Enables VLAN if the check box is selected. VLAN is disabled by default.
Indicates the frame priority level, which can be used to prioritize different types of traffic (voice, video, and data).
Valid priorities are 0 to 7; where 0 (default) is the lowest and
7 is the highest.
Displays the VLAN ID (identification). Valid VLAN IDs are:
1 to 4000 and 4021 to 4094. The default VLAN ID is 1.
4 Click Apply to save the settings.
You can also access this page from the Chassis Overview ï‚® Servers ï‚® Setup tab ï‚® VLAN subtab.
Using the CMC Web Interface 153
Adding and Configuring CMC Users
To manage your system with CMC and maintain system security, create unique users with specific administrative permissions (or role-based authority ). For additional security, you can also configure alerts that are e-mailed to specific users when a specific system event occurs.
User Types
There are two types of users: CMC users and iDRAC users. CMC users are also known as "chassis users." Since iDRAC resides on the server, iDRAC users are also known as "server users."
CMC users can be local users or directory service users. iDRAC users can also be local users or directory service users.
Except where a CMC user has Server Administrator privilege, privileges granted to a CMC user are not automatically transferred to the same user on a server, because server users are created independently from CMC users.
In other words, CMC Active Directory users and iDRAC Active Directory users reside on two different branches in the Active Directory tree. To create a local server user, the Configure Users must log in to the server directly. The
Configure Users cannot create a server user from CMC or vice versa. This rule protects the security and integrity of the servers.
Table 5-40. User Types
Privilege
CMC Login
User
Description
User can log in to CMC and view all the CMC data, but cannot add or modify data or execute commands.
It is possible for a user to have other privileges without the CMC
Login User privilege. This feature is useful when a user is temporarily not allowed to login. When that user’s CMC Login
User privilege is restored, the user retains all the other privileges previously granted.
154 Using the CMC Web Interface
Table 5-40. User Types (continued)
Privilege
Chassis
Configuration
Administrator
User
Configuration
Administrator
Description
User can add or change data that:
• Identifies the chassis, such as chassis name and chassis location
• Is assigned specifically to the chassis, such as IP mode (static or
DHCP), static IP address, static gateway, and static subnet mask
• Provides services to the chassis, such as date and time, firmware update, and CMC reset.
• Is associated with the chassis, such as slot name and slot priority.
Although these properties apply to the servers, they are strictly chassis properties relating to the slots rather than the servers themselves. For this reason, slot names and slot priorities can be added or changed whether or not servers are present in the slots.
When a server is moved to a different chassis, it inherits the slot name and priority assigned to the slot it occupies in the new chassis. Its previous slot name and priority remain with the previous chassis.
User can:
• Add a new user
• Delete an existing user
• Change a user's password
• Change a user's privileges
• Enable or disable a user's login privilege but retain the user's name and other privileges in the database.
User can clear the hardware log and CMC log.
Clear Logs
Administrator
Chassis Control
Administrator
(Power
Commands)
CMC users with the Chassis Power Administrator privilege can perform all power-related operations:
• Control chassis power operations, including power on, power off, and power cycle.
Using the CMC Web Interface 155
Table 5-40. User Types (continued)
Privilege
Server
Administrator
Description
This a blanket privilege granting a CMC user all rights to perform any operation on any servers present in the chassis.
When a user with Server Administrator privilege issues an action to be performed on a server, the CMC firmware sends the command to the targeted server without checking the user's privileges on the server. In other words, the Server Administrator privilege overrides any lack of administrator privileges on the server.
Without the Server Administrator privilege, a user created on the chassis can only execute a command on a server when all of the following conditions are true:
• The same user name exists on the server
• The same user name must have the exact same password on the server
• The user must have the privilege to execute the command
When a CMC user who does not have Server Administrator privilege issues an action to be performed on a server, CMC sends a command to the targeted server with the user’s login name and password. If the user does not exist on the server, or if the password does not match, the user is denied the ability to perform the action.
If the user exists on the target server and the password matches, the server responds with the privileges of which the user was granted on the server. Based on the privileges responding from the server, CMC firmware decides if the user has the right to perform the action.
Listed below are the privileges and the actions on the server to which the Server Administrator is entitled. These rights are applied only when the chassis user does not have the Server
Administrative privilege on the chassis.
156 Using the CMC Web Interface
Table 5-40. User Types (continued)
Privilege Description
Server
Administrator
(continued)
Server Configuration Administrator:
• Set IP address
• Set gateway
• Set subnet mask
• Set first boot device
Configure Users:
• Set iDRAC root password
• iDRAC reset
Server Control Administrator:
• Power on
• Power off
• Power cycle
• Graceful shutdown
• Server Reboot
Test Alert User User can send test alert messages.
Debug
Command
Administrator
User can execute system diagnostic commands.
Fabric A
Administrator
Fabric B
Administrator
Fabric C
Administrator
Super User
User can set and configure the Fabric A IOM, which resides in either slot A1 or slot A2 of the I/O slots.
User can set and configure the Fabric B IOM, which resides in either slot B1 or slot B2 of the I/O slots.
User can set and configure the Fabric C IOM, which resides in either slot C1 or slot C2 of the I/O slots.
User has root access to CMC and has User Configuration
Administrator and Login to CMC User privileges. Only users with Super User privileges can grant new or existing users Debug
Command Administrator and Super User privileges.
Using the CMC Web Interface 157
The CMC user groups provide a series of user groups that have pre-assigned user privileges.
NOTE: If you select Administrator, Power User, or Guest User, and then add or remove a privilege from the pre-defined set, the CMC Group automatically changes to Custom.
.
Table 5-41. CMC Group Privileges
User Group
Administrator
Power User
Guest User
Privileges Granted
• CMC Login User
• Chassis Configuration Administrator
• User Configuration Administrator
• Clear Logs Administrator
• Server Administrator
• Test Alert User
• Debug Command Administrator
• Fabric A Administrator
• Fabric B Administrator
• Fabric C Administrator
• Login
• Clear Logs Administrator
• Chassis Control Administrator (Power Commands)
• Server Administrator
• Test Alert User
• Fabric A Administrator
• Fabric B Administrator
• Fabric C Administrator
Login
158 Using the CMC Web Interface
Table 5-41. CMC Group Privileges (continued)
User Group
Custom
None
Privileges Granted
Select any combination of the following permissions:
• CMC Login User
• Chassis Configuration Administrator
• User Configuration Administrator
• Clear Logs Administrator
• Chassis Control Administrator (Power Commands)
• Super User
• Server Administrator
• Test Alert User
• Debug Command Administrator
• Fabric A Administrator
• Fabric B Administrator
• Fabric C Administrator
No assigned permissions.
Table 5-42. Comparison of Privileges Between CMC Administrators, Power Users, and Guest Users
Privilege Set Administrator
Permissions
Power User
Permissions
Guest User
Permissions
CMC Login User
Chassis Configuration
Administrator
User Configuration Administrator
Clear Logs Administrator
Chassis Control Administrator
(Power Commands)
Using the CMC Web Interface 159
Table 5-42. Comparison of Privileges Between CMC Administrators, Power Users, and Guest Users (continued)
Privilege Set Administrator
Permissions
Power User
Permissions
Guest User
Permissions
Super User
Server Administrator
Test Alert User
Debug Command Administrator
Fabric A Administrator
Fabric B Administrator
Fabric C Administrator
Adding and Managing Users
From the Users and User Configuration pages in the Web interface, you can view information about CMC users, add a new user, and change settings for an existing user.
You can configure up to 16 local users. If additional users are required and your company uses Microsoft Active Directory or generic Lightweight
Directory Access Protocol (LDAP) services, you can configure it to provide access to CMC. Active Directory configuration allows you to add and control
CMC user privileges to your existing users in your Active Directory software,
in addition to the 16 local users. For more information, see "Using the CMC
Directory Service" on page 241. For more information about LDAP, see the
"Using CMC with the Lightweight Directory Access Protocol Services" section.
160 Using the CMC Web Interface
Users can be logged in through Web interface, Telnet serial, SSH, and iKVM sessions. A maximum of 22 active sessions (Web interface, Telnet serial, SSH, and iKVM, in any combination) can be divided among users.
NOTE: For added security, it is strongly recommended that you change the default password of the root (User 1) account. The root account is the default administrative account that ships with CMC. To change the default password for the root account, click User ID 1 to open the User Configuration page. Help for that page is available through the Help link at the top right corner of the page.
To add and configure CMC users:
NOTE: You must have Configure Users privilege to perform the following steps.
1 Log in to the Web interface.
2 Click the User Authentication tab. The Local Users page appears, listing each user’s user ID , user name, CMC privilege, and l ogin state, including those of the root user. User IDs available for configuration have no user information displayed.
3 Click an available user ID number. The User Configuration page displays.
To refresh the contents of the Users page, click Refresh . To print the contents of the Users age, click Print .
4 Select general settings for the user.
Table 5-43. General User Settings for Configuring a New or Existing CMC Username and Password
Property
User ID
Enable User
Description
(Read only) Identifies a user by one of 16 preset, sequential numbers used for CLI scripting purposes. The User ID identifies the particular user when configuring the user through the CLI tool
(RACADM). You cannot edit the User ID.
If you are editing information for user root, this field is static.
You cannot edit the user name for root.
Enables or disables the user's access to CMC.
Using the CMC Web Interface 161
162
Table 5-43. General User Settings for Configuring a New or Existing CMC Username and Password (continued)
Property
User Name
Change
Password
Password
Confirm
Password
Description
Sets or displays the unique CMC user name associated with the user. The user name can contain up to 16 characters. CMC user names cannot include forward slash (/) or period (.) characters.
NOTE: If you change the user name, the new name does not appear in the user interface until your next login. Any user logging in after you apply the new user name can see the change immediately.
Allows an existing user’s password to be changed. Set the new password in the New Password field.
The Change Password check box cannot be selected if you are configuring a new user. You can select it only when changing an existing user setting.
Sets a new password for an existing user. To change the password, you must also select the Change Password check box. The password can contain up to 20 characters, which display as dots as you type.
Verifies the password you entered in the New Password field.
NOTE: The New Password and Confirm New Password fields are editable only when you are (1) configuring a new user; or (2) editing the settings for an existing user, and the Change Password check box is selected.
5
Assign the user to a CMC user group. Table 5-40 describes CMC user
privileges.
When you select a user privilege setting from the CMC Group drop-down menu, the enabled privileges (shown as checked boxes in the list) display according to the pre-defined settings for that group.
You can customize the privileges settings for the user by checking or un-checking boxes. After you have selected a CMC Group or made
Custom user privilege selections, click Apply Changes to keep the settings.
6 Click Apply Changes .
To refresh the contents of the User Configuration page, click Refresh .
To print the contents of the User Configuration page, click Print .
Using the CMC Web Interface
Configuring and Managing Microsoft Active
Directory Certificates
NOTE: To configure Active Directory settings for CMC, you must have Chassis
Configuration Administrator privilege.
NOTE: For more information about Active Directory configuration and how to
You can use the Microsoft Active Directory service to configure your software to provide access to CMC. Active Directory service allows you to add and control the CMC user privileges of your existing users.
To access the Active Directory Main Menu page:
1 Log in to the Web interface.
2 Click the User Authentication tab, and then click the Directory Services subtab. Select the radio button for Microsoft Active Directory Standard
Schema or Extended Schema. The Active Directory tables appear.
Common Settings
This section allows you to configure and view common Active Directory settings for CMC.
Table 5-44. Common Settings
Field
Enable Active
Directory
Description
Enables Active Directory Login on CMC. You must install SSL certificates for the Active Directory servers signed by the same certificate authority and upload it to CMC.
Using the CMC Web Interface 163
Table 5-44. Common Settings (continued)
Field Description
Enable Smart Card
Login
Enables Active Directory inter-operation based on the Kerberos
Authentication supported by a Dell-supplied, auto-installed browser plug-in and Smart Card usage. To enable Smart Card, select the check box. To disable Smart Card, clear the check box. If you enable Smart Card, you must also configure your
Microsoft Windows Client Workstation to correctly operate with Smart Card Reader functionality. This involves installing the correct drivers for the Smart Card Reader being used and also, the correct drivers for the actual Smart Card used. These
Smart Card drivers vary by vendor. The Smart Card must be properly programmed with the necessary credentials using the
Smart Card Enrollment Services provided by the appropriate
Active Directory Server.
NOTE: Smart Card Login and Single Sign-On selections are mutually exclusive. You can select only one at a time.
Enable Single
Sign-On
Enables CMC to utilize Active Directory . To enable Single
Sign-On , select the check box. To disable Single Sign-On , clear the check box. If you enable Single Sign-On , you must also set the Active Directory properties and select the schema you want to use.
NOTE: Smart Card Login and Single Sign-On selections are mutually exclusive. You can select only one at a time.
164 Using the CMC Web Interface
Table 5-44. Common Settings (continued)
Field
Enable SSL
Certificate
Validation
Description
Enables SSL certificate validation for CMC's Active Directory
SSL connection. To disable the SSL certificate validation, clear the check box.
Warning: Disabling this feature may expose the authentication to a man-in-the-middle attack.
The browser operation requires that CMC be accessed through a HTTP URL which contains a fully qualified domain address for CMC, that is http://cmc-6g2wxf1.dom.net
. A plain IP address for CMC does not result in proper Single Sign-On operation. To support fully qualified domain addresses, it is necessary to register CMC with the Domain Name Service of the Active Directory Server.
If a Single Sign-On browser authentication is unsuccessful, the usual Local or Active Directory username/password browser authentication method is automatically presented. Similarly, a
Logout action after a successful Single Sign-On presents the username/password method. Single Sign-On usage is intended for convenience and is not meant to be restrictive.
NOTE: Smart Card based browser authentication is only supported for Microsoft Windows Clients and Internet Explorer browsers.
The Dell supplied, auto-loaded, browser plug-in (ActiveX control) is dependent on the Microsoft Windows Client operating system having the following runtime component preinstalled - Microsoft Visual C++ 2005 Redistributable Package
(x86). The following link may help locate the component: http://www.microsoft.com/downloads/details.aspx?FamilyID=
32BC1BEE-A3F9-4C13-9C99-
220B62A191EE&displaylang=en . The Windows Client needs
'elevated privileges' to successfully install the ActiveX Control.
Similarly, the browser configuration needs the capability to accept installation of 'unsigned' ActiveX Controls.
Using the CMC Web Interface 165
166
Table 5-44. Common Settings (continued)
Field
Root Domain
Name
Description
Enabling Smart Card enforces a Smart Card Only policy for browser authentication. All other methods of browser authentication such as Local or Active Directory username/password authentication are restricted. If the Smart
Card Only usage enforcement policy is to be adopted, it is important that the Smart Card operation be fully validated before all other access methods to CMC are disabled.
Otherwise, it is possible to inadvertently lock all access to
CMC.
Specifies the domain name used by Active Directory. The root domain name is the fully qualified root domain name for the forest.
NOTE: The root domain name must be a valid domain name using the x.y naming convention, where x is a 1-256 character ASCII string with no blank spaces between characters, and y is a valid domain type such as com, edu, gov, int, mil, net, or org.
AD Timeout
Specify AD Server to search
(optional)
Sets the time in seconds after which an idle Active Directory session is automatically closed.
Valid values: 15-300 seconds
Default: 90 seconds
Enables (when checked) directed call on the domain controller and global catalog. If you enable this option, you must also specify the domain controller and global catalog locations in the following settings.
NOTE: The name on the Active Directory CA Certificate does not be matched against the specified Active Directory server or the
Global Catalog server.
Domain Controller Specifies the server where your Active Directory service is installed. This option is valid only if Specify AD Server to search (Optional) is enabled.
Global Catalog Specifies the location of the global catalog on the Active
Directory domain controller. The global catalog provides a resource for searching an Active Directory forest.
This option is valid only if Specify AD Server to search
(Optional) is enabled.
Using the CMC Web Interface
Standard Schema Settings
Displayed when Microsoft Active Directory (Standard Schema) is selected, this section presents the role groups with associated names, domains, and privileges for any role groups that have already been configured.
To change the settings for a role group, click the role group button in the Role
Groups list.
NOTE: If you click a role group link prior to applying any new settings you have made, you lose those settings. To avoid losing any new settings, click Apply before clicking a role group button.
The Configure Role Group page displays:
• Group Name – The name that identifies the role group in the Active
Directory associated with the CMC card.
• Group Domain – The domain where the group is located.
• Group Privilege – The privilege level for the group.
Click Apply to save the settings.
Click Go back to Configuration Page to return to the Directory Services page.
To refresh the contents of the Directory Services page, click Refresh .
To print the contents of the Directory Services page, click Print .
Extended Schema Settings
Displayed when Microsoft Active Directory (Extended Schema) is selected, this section presents the following properties:
• CMC Device Name - Displays the name of the RAC Device Object you created for CMC. The CMC Device Name uniquely identifies the CMC card in Active Directory. The CMC Device Name must be the same as the common name of the new RAC Device Object you created in your domain controller. The CMC Name must be a 1-256 character ASCII string with no blank spaces between characters. For more information about RAC
Device Objects, see your CMC User's Guide.
Using the CMC Web Interface 167
• CMC Domain Name - Displays the DNS name (string) of the domain where the Active Directory RAC Device Object resides. The CMC domain name must be a valid domain name consisting of x .
y , where x is a 1-256 character ASCII string with no blank spaces between characters, and y is a valid domain type such as com, edu, gov, int, mil, net, or org.
Managing Active Directory Certificates
This sections displays the properties for the Active Directory certificate that was recently uploaded to the CMC. If you uploaded a certificate, use this information to verify that the certificate is valid and has not expired.
NOTE: By default, CMC does not have a certificate authority-issued server certificate for Active Directory. You must upload a current, certificate authoritysigned server certificate.
The following properties for the certificate are displayed:
• Serial Number - The certificate's serial number.
• Subject Information - The certificate's subject (name of the person or company certified).
• Issuer Information - The certificate's issuer (name of the Certificate
Authority).
• Valid From - The starting date of the certificate.
• Valid To - The expiry date of the certificate.
Use the following controls to upload and download this certificate:
• Upload - Initiates the upload process for the certificate. This certificate, which you obtain from Active Directory, grants access to CMC.
• Download - Initiates the download process. You are prompted for the location to save the file. When you select this option and click Next , a File
Download dialog box appears. Use this dialog box to specify a location on your management station or shared network for the server certificate.
NOTE: By default, CMC does not have a certificate authority-issued server certificate for Active Directory. You must upload a current, certificate authoritysigned server certificate.
168 Using the CMC Web Interface
Kerberos Keytab
You can upload a Kerberos Keytab generated on the associated Active
Directory Server. You can generate the Kerberos Keytab from the Active
Directory Server by executing the ktpass.exe
utility. This keytab establishes a trust relationship between the Active Directory Server and CMC.
NOTE: CMC does not have a Kerberos Keytab for Active Directory. You must upload
The following actions are allowed:
• Browse - Opens a Browse dialog box, from which you select the server certificate you want to upload.
• Upload - Initiates the upload process for the certificate using the file path you specify.
Configuring and Managing Generic Lightweight
Directory Access Protocol Services
You can use the Generic Lightweight Directory Access Protocol (LDAP)
Service to configure your software to provide access to CMC. LDAP allows you to add and control the CMC user privileges of your existing users.
NOTE: To configure LDAP settings for CMC, you must have Chassis Configuration
Administrator privilege.
To view and configure LDAP:
1 Log in to the Web interface.
2 Click the User Authentication tab, and then click the Directory Services subtab. The Directory Services page appears.
3 Click the radio button associated with Generic LDAP.
4 Configure the options shown and click Apply .
Using the CMC Web Interface 169
The following configuration options are available.
Table 5-45. Common Settings
Setting
Generic LDAP
Enabled
Use Distinguished
Name to Search
Group Membership
Enable SSL
Certificate Validation
Bind DN
Description
Enables the generic LDAP service on CMC.
Specifies the distinguished name (DN) of LDAP groups whose members are allowed access to the device.
Password
Base DN to Search
Attribute of User
Login
Attribute of Group
Membership
Search Filter
If checked, CMC uses the CA certificate to validate the
LDAP server certificate during SSL handshake.
Specifies the distinguished name of a user used to bind to the server when searching for the login user's DN. If not provided an anonymous bind is used.
A bind password to use in conjunction with the bind DN.
NOTE: The bind password is sensitive data, and must be properly protected.
The DN of the branch of the directory where all searches must start from.
Specifies the attribute to search for. If not configured, the default is to use uid. It is recommended to be unique within the chosen base DN, otherwise a search filter must be configured to ensure the uniqueness of the login user.If the user DN cannot be uniquely identified by searching the combination of attribute and search filter, login fails with an error.
Specifies the LDAP attribute that is used to check for group membership. This must be an attribute of the group class. If not specified, the member and unique member attributes are used.
Specifies a valid LDAP search filter. This is used if the user attribute cannot uniquely identify the login user within the chosen base DN. If not provided, defaults to (objectClass=
*), which searches for all objects in the tree. The maximum length of this property is 1024 characters.
170 Using the CMC Web Interface
Table 5-45. Common Settings (continued)
Setting
Network Timeout
(seconds)
Search Timeout
(seconds)
Description
Sets the time in seconds after which an idle LDAP session is automatically closed.
Sets the time in seconds after which a search is automatically closed.
Selecting Your LDAP Servers
You can configure the server to use with Generic LDAP in two ways. Static
Servers allows the administrator to place a FQDN or IP address within the field. Alternatively, a list of LDAP servers can be retrieved by looking up their
SRV record within the DNS. The following are the properties in the LDAP
Servers section:
• Use Static LDAP Servers - Selecting this option causes the LDAP service to use the specified servers with the port number provided (see details below).
NOTE: You must select Static or DNS.
• LDAP Server Address - Specify the FQDN or IP of the LDAP server. To specify multiple, redundant LDAP servers that serve the same domain, provide the list of all servers separated by comma. CMC tries to connect to each server in turn, until it makes a successful connection.
• LDAP Server Port - Port of LDAP over SSL, default to 636 if not configured. Non-SSL port is not supported in CMC version 3.0 as the password cannot be transported without SSL.
• Use DNS to find LDAP Servers - Selecting this option causes LDAP to use the search domain and the service name through DNS. You must select
Static or DNS.
The following DNS query is performed for SRV records:
_[Service Name]._tcp.[Search Domain] where < Search Domain > is the root level domain to use within the query and
< Service Name > is the service name to use within the query. For example:
_ldap._tcp.dell.com
where ldap is the service name and dell.com
is the search domain.
Using the CMC Web Interface 171
Managing LDAP Group Settings
The table in the Group Settings section lists role groups, displaying associated names, domains, and privileges for any role groups that are already configured.
• To configure a new role group, click a role group name that does not have a name, domain, and privilege listed.
• To change the settings for an existing role group, click the role group name.
When you click a role group name, the Configure Role Group page appears.
Help for that page is available through the Help link at the top right corner of the page.
Managing LDAP Security Certificates
This sections displays the properties for the LDAP certificate recently uploaded to CMC. If you uploaded a certificate, use this information to verify that the certificate is valid and has not expired.
NOTE: By default, CMC does not have a certificate authority-issued server certificate for Active Directory. You must upload a current, certificate authoritysigned server certificate.
The following properties for the certificate are displayed:
• Serial Number - The certificate's serial number.
• Subject Information - The certificate's subject (name of the person or company certified).
• Issuer Information - The certificate's issuer (name of the Certificate
Authority.
• Valid From - The starting date of the certificate.
• Valid To - The expiry date of the certificate.
172 Using the CMC Web Interface
Use the following controls to upload and download this certificate:
• Upload - Initiates the upload process for the certificate. This certificate, which you obtain from your LDAP server, grants access to CMC.
• Download - Initiates the download process. You are prompted for the location to save the file. When you select this option and click Next , a File
Download dialog box appears. Use this dialog box to specify a location on your management station or shared network for the server certificate.
Securing CMC Communications Using SSL and
Digital Certificates
This subsection provides information about the following data security features that are incorporated in your CMC:
• Secure Sockets Layer (SSL)
• Certificate Signing Request (CSR)
• Accessing the SSL Main Menu
• Generating a new CSR
• Uploading a Server Certificate
• Viewing a Server Certificate
Secure Sockets Layer (SSL)
CMC includes a Web server that is configured to use the industry-standard
SSL security protocol to transfer encrypted data over the Internet. Built upon public-key and private-key encryption technology, SSL is a widely accepted technique for providing authenticated and encrypted communication between clients and servers to prevent eavesdropping across a network.
SSL allows an SSL-enabled system to perform the following tasks:
• Authenticate itself to an SSL-enabled client.
• Allow the client to authenticate itself to the server.
• Allow both systems to establish an encrypted connection.
This encryption process provides a high level of data protection. CMC employs the 128-bit SSL encryption standard, the most secure form of encryption generally available for Internet browsers in North America.
Using the CMC Web Interface 173
174
The CMC Web server includes a Dell self-signed SSL digital certificate
(Server ID). To ensure high security over the Internet, replace the Web server
SSL certificate by submitting a request to CMC to generate a new Certificate
Signing Request (CSR).
Certificate Signing Request (CSR)
A CSR is a digital request to a certificate authority (referred to as a CA in the
Web interface) for a secure server certificate. Secure server certificates ensure the identity of a remote system and ensure that information exchanged with the remote system cannot be viewed or changed by others. To ensure the security for your CMC, it is strongly recommended that you generate a CSR, submit the CSR to a certificate authority, and upload the certificate returned from the certificate authority.
A certificate authority is a business entity that is recognized in the IT industry for meeting high standards of reliable screening, identification, and other important security criteria. Examples of CAs include Thawte and VeriSign.
After the certificate authority receives your CSR, they review and verify the information the CSR contains. If the applicant meets the certificate authority’s security standards, the certificate authority issues a certificate to the applicant that uniquely identifies that applicant for transactions over networks and on the Internet.
After the certificate authority approves the CSR and sends you a certificate, you must upload the certificate to the CMC firmware. The CSR information stored on the CMC firmware must match the information contained in the certificate.
Accessing the SSL Main Menu
NOTE: To configure SSL settings for CMC, you must have Chassis Configuration
Administrator privilege.
NOTE: Any server certificate you upload must be current (not expired) and signed by a certificate authority.
1 Log in to the Web interface.
2 Click the Network tab, and then click the SSL subtab. The SSL Main
Menu page appears.
Use the SSL Main Menu page options to generate a CSR to send to a certificate authority. The CSR information is stored on the CMC firmware.
Using the CMC Web Interface
Generating a New Certificate Signing Request
To ensure security, it is strongly recommended that you obtain and upload a secure server certificate to CMC. Secure server certificates ensure the identity of a remote system and that information exchanged with the remote system cannot be viewed or changed by others. Without a secure server certificate,
CMC is vulnerable to access from unauthorized users.
Table 5-46. SSL Main Menu Options
Field
Generate a New
Certificate Signing
Request (CSR)
Description
Select this option and click Next to open the Generate
Certificate Signing Request (CSR) page, where you can generate a CSR request for a secure Web certificate to submit to a certificate authority.
NOTE: Each new CSR overwrites any previous CSR on CMC.
For a certificate authority to accept your CSR, the CSR in CMC must match the certificate returned from the certificate authority.
Upload Server
Certificate Based on
Generated CSR
Upload Webserver key and Certificate
Select this option and click Next to display the Certificate
Upload page, where you can upload an existing certificate that your company holds title to and uses to control access to CMC.
NOTE: Only X509, Base 64-encoded certificates are accepted by CMC. DER-encoded certificates are not accepted.
Uploading a new certificate replaces the default certificate you received with your CMC.
Select this option and click Next to open the Webserver Key and Certificate Upload page, where you can upload an existing Web server key and server certificate that your company holds title to and uses to control access to CMC.
NOTE: Only X.509, Base64 encoded certificates are accepted by CMC. Binary DER-encoded certificates are not accepted.
Uploading a new certificate replaces the default certificate you received with your CMC.
View Server Certificate Select the option and click the Next button to open the
View Server Certificate page where you can view the current server certificate.
Using the CMC Web Interface 175
To obtain a secure server certificate for CMC, you must submit a Certificate
Signing Request (CSR) to a certificate authority of your choice. A CSR is a digital request for a signed, secure server certificate containing information about your organization and a unique, identifying key.
When a CSR is generated from the Generate Certificate Signing Request
(CSR) page, you are prompted to save a copy to your management station or shared network, and the unique information used to generate the CSR is stored on CMC. This information is used later to authenticate the server certificate you receive from the certificate authority. After you receive the server certificate from the certificate authority, you must then upload it to CMC.
NOTE: For CMC to accept the server certificate returned by the certificate authority, authentication information contained in the new certificate must match the information that was stored on CMC when the CSR was generated.
CAUTION: When a new CSR is generated, it overwrites any previous CSR on
CMC. If a pending CSR is overwritten before its server certificate is granted from a certificate authority, CMC does not accept the server certificate because the information it uses to authenticate the certificate has been lost. Take caution when generating a CSR to prevent overwriting any pending CSR.
To generate a CSR:
1 From the SSL Main Menu page, select Generate a New Certificate
Signing Request (CSR) , and then click Next . The Generate Certificate
Signing Request (CSR) page displays.
2 Type a value for each CSR attribute value.
3 Click Generate . A File Download dialog box appears.
4 Save the csr.txt
file to your management station or shared network.
(You may also open the file at this time and save it later.) You must later submit this file to a certificate authority.
176 Using the CMC Web Interface
Table 5-47. Generate Certificate Signing Request (CSR) Page Options
Field Description
Common Name The exact name being certified (usually the Web server's domain name, for example, www.xyzcompany.com/ ).
Valid : Alphanumeric characters (A–Z, a–z, 0–9); hyphens, underscores, and periods.
Not valid : Non-alphanumeric characters not noted above
(such as, but not limited to, @ # $ % & *); characters used primarily in non-English languages, such as ß, å, é, ü.
Organization Name The name associated with your organization (example: XYZ
Corporation ).
Valid : Alphanumeric characters (A–Z, a–z, 0–9); hyphens, underscores, periods, and spaces.
Not valid : Non-alphanumeric characters not noted above (such as, but not limited to, @ # $ % & *).
Organization Unit The name associated with an organizational unit, such as a department (example: Enterprise Group).
Valid : Alphanumeric characters (A–Z, a–z, 0–9); hyphens, underscores, periods, and spaces.
Not valid : Non-alphanumeric characters not noted above (such as, but not limited to, @ # $ % & *).
Locality The city or other location of your organization
(examples: Atlanta , Hong Kong ).
Valid : Alphanumeric characters (A–Z, a–z, 0–9) and spaces.
Not Valid : Non-alphanumeric characters not noted above
(such as, but not limited to, @ # $ % & *).
State The state, province, or territory where the entity that is applying for a certification is located (examples: Texas , New South
Wales , Andhra Pradesh ).
NOTE: Do not use abbreviations.
Valid : Alphanumeric characters (upper- and lower-case letters;
0–9); and spaces.
Not valid : Non-alphanumeric characters not noted above
(such as, but not limited to, @ # $ % & *).
Using the CMC Web Interface 177
178
Table 5-47. Generate Certificate Signing Request (CSR) Page Options (continued)
Field
Country
Description
The country where the organization applying for certification is located.
Your organization's e-mail address. You may type any e-mail address you want to have associated with the CSR. The e-mail address must be valid, containing the at (@) sign (example: [email protected]
).
NOTE: This e-mail address is an optional field.
Uploading a Server Certificate
1 From the SSL Main Menu page, select Upload Server Certificate Based on Generated CSR , and then click Next . The Certificate Upload page displays.
2 Type the file path in the text field, or click Browse to select the file.
3 Click Apply . If the certificate is invalid, an error message displays.
NOTE: The File Path value displays the relative file path of the certificate you are uploading. You must type the absolute file path, which includes the full path and the complete file name and file extension.
To refresh the contents of the Certificate Upload page, click Refresh .
To print the contents of the Certificate Upload page, click Print .
Uploading Webserver Key and Certificate
1 Select Upload Webserver Key and Certificate option, and then click Next .
2 Enter Private Key File using the browse menu.
3 Enter Certificate File using the browse menu.
4 After both the files are uploaded, click Apply . If the Web server key and certificate do not match, an error message is displayed.
NOTE: Only X509, Base-64 encoded certificates are accepted by CMC. Certificates using other encoding schemes such as DER, are not accepted. Uploading a new certificate replaces the default certificate you received with your CMC.
NOTE: To upload a Web server key and server certificate, you must have Chassis
Configuration Administrator privileges.
Using the CMC Web Interface
NOTE: CMC resets and becomes temporarily unavailable after the certificate has been uploaded successfully. To avoid disconnecting other users during a reset, notify authorized users who might log into CMC and check for active sessions in the
Sessions page under the Network tab.
Viewing a Server Certificate
From the SSL Main Menu page, select View Server Certificate , and then click Next . The View Server Certificate page displays.
Table 5-48 describes the fields and associated descriptions listed in the
Certificate window.
Table 5-48. Certificate Information
Field
Serial
Subject
Issuer notBefore notAfter
Description
Certificate serial number.
Certificate attributes entered by the subject.
Certificate attributes returned by the issuer.
Issue date of the certificate.
Expiration date of the certificate.
To refresh the contents of the View Server Certificate page, click Refresh .
To print the contents of the View Server Certificate page, click Print .
Managing Sessions
The Sessions page displays all current instances of connections to the chassis and allows you to terminate any active session.
NOTE: To terminate a session, you must have Chassis Configuration Administrator privilege.
To manage or terminate a session:
1 Log in to CMC through the Web.
2 Click the Network tab then click the Sessions subtab.
3 On the Sessions page, locate the session you want to terminate and click the appropriate button.
Using the CMC Web Interface 179
Table 5-49. Sessions Properties
Property
Session ID
Username
IP Address
Session Type
Terminate
Description
Displays the sequentially generated ID number for each instance of a login.
Displays the user's login name (local user or Active Directory user).
Examples of Active Directory user names are [email protected]
, domain.com/name , domain.com\name .
Displays the user’s IP address.
Describes the session type: Telnet, serial, SSH, Remote RACADM,
SMASH CLP, WSMAN, or a GUI session.
Allows you to terminate any of the sessions listed, except for your own. To terminate the associated session, click the button. This column is displayed only if you have Chassis Configuration
Administrator privileges.
Configuring Services
CMC includes a Web server that is configured to use the industry-standard
SSL security protocol to accept and transfer encrypted data from and to clients over the Internet. The Web server includes a Dell self-signed SSL digital certificate (Server ID) and is responsible for accepting and responding to secure HTTP requests from clients. This service is required by the Web interface and remote CLI tool for communicating to CMC.
NOTE: The remote (RACADM) CLI tool and the Web interface use the Web server.
In the event that the Web Server is not active, the remote RACADM and the Web interface are not operable.
NOTE: In an event of a Web server reset, wait at least one minute for the services to become available again. A Web server reset usually happens as a result of any of the following events: the network configuration or network security properties are changed through the CMC Web user interface or RACADM; the Web Server port configuration is changed through the Web user interface or RACADM; CMC is reset; a new SSL server certificate is uploaded
NOTE: To modify service settings, you must have Chassis Configuration
Administrator privilege.
180 Using the CMC Web Interface
To configure CMC services:
1 Log in to the CMC Web interface.
2 Click the Network tab.
3 Click the Services subtab. The Services page appears.
4 Configure the following services as required:
• CMC serial console (Table 5-50)
5 Click Apply , and then update all default time outs and maximum time out limits
Table 5-50. CMC Serial Console Settings
Setting
Enabled
Redirect Enabled
Description
Enables Telnet console interface on CMC.
Default : Unchecked (disabled)
Enables the serial/text console redirection to the server through your serial/Telnet/SSH client from CMC.
The CMC connects to iDRAC that internally connects to the server COM2 port.
Configuration options: Checked (enabled), unchecked (disabled)
Default: Checked (enabled)
Using the CMC Web Interface 181
182
Table 5-50. CMC Serial Console Settings (continued)
Setting
Idle Timeout
Baud Rate
Authentication
Disabled
Escape Key
Description
Displays the number of seconds before an idle serial session is automatically disconnected. A change to the Timeout setting takes effect at the next login; it does not affect the current session.
Timeout Range : 0 or 60 to 10800 seconds. To disable the
Timeout feature, enter 0.
Default : 1800 seconds
Displays the data speed on the external serial port on the CMC.
Configuration options: 9600, 19200, 28800, 38400, 57600, and 115200 bps.
Default : 115200 bps
Enables CMC Serial Console login authentication.
Default : Unchecked (disabled)
Allows you to specify the Escape key combination that terminates serial/text console redirection when using the connect or racadm connect command.
Default: ^\
(Hold <Ctrl> and type a backslash (\) character)
NOTE: The caret character ^ represents the <Ctrl> key.
Configuration options:
• Decimal value (example: 95)
• Hexadecimal value (example: 0x12)
• Octal value (example: 007)
• ASCII value (example: ^a)
ASCII values may be represented using the following
Escape key codes:
• Esc followed by any alphabetic character (a-z, A-Z)
• Esc followed by the following special characters: [ ] \ ^ _
• Maximum Allowed Length: 4
Using the CMC Web Interface
Table 5-50. CMC Serial Console Settings (continued)
Setting
History Size Buffer
Login Command
Description
Displays the maximum size of the serial history buffer, which holds the last characters written to the Serial
Console.
Default: 8192 characters
Specifies the serial command that is automatically executed when a user logs into the CMC Serial Console interface.
Example: connect server-1
Default: [Null]
Table 5-51. Web Server Settings
Setting
Enabled
Max Sessions
Description
Enables Web Server services (access through remote
RACADM and the Web interface) for CMC.
Default : Checked (enabled)
Displays the maximum number of simultaneous Web user interface sessions allowed for the chassis. A change to the
Max Sessions property takes effect at the next login; it does not affect current Active Sessions (including your own).
The remote RACADM is not affected by the Max Sessions property for the Web Server.
Allowed range : 1–4
Default : 4
NOTE: If you change the Max Sessions property to a value less than the current number of Active Sessions and then log out, you cannot log back in until the other sessions have been terminated or expired.
Using the CMC Web Interface 183
Table 5-51. Web Server Settings (continued)
Setting Description
Idle Timeout
HTTP Port Number
Displays the number of seconds before an idle Web user interface session is automatically disconnected. A change to the Timeout setting takes effect at the next login; it does not affect the current session.
Timeout range : 60 to 10800 seconds.
Default : 1800 seconds
Displays the default port used by CMC that listens for a server connection.
NOTE: When you provide the HTTP address on the browser, the Web server automatically redirects and uses HTTPS.
If the default HTTP port number (80) has been changed, you must include the port number in the address in the browser address field, as shown: http://< IP address >:< port number > where IP address is the IP address for the chassis, and port number is the HTTP port number other than the default of 80.
Configuration range: 10–65535
Default : 80
HTTPS Port Number Displays the default port used by CMC that listens for a secured server connection.
If the default HTTPS port number (443) has been changed, you must include the port number in the address in the browser address field, as shown: https://< IP address >:< port number > where < IP address > is the IP address for the chassis, and
< port number > is the HTTPS port number other than the default of 443.
Configuration range: 10–65535
Default : 443
184 Using the CMC Web Interface
Table 5-52. SSH Settings
Setting
Enabled
Max Sessions
Idle Timeout
Port Number
Description
Enables the SSH on CMC.
Default : Checked (enabled)
The maximum number of simultaneous SSH sessions allowed for the chassis. A change to this property takes effect at the next login; it does not affect current Active
Sessions (including your own).
Configurable range : 1–4
Default : 4
NOTE: If you change the Max Sessions property to a value less than the current number of Active Sessions and then log out, you cannot log in again till the other sessions have been terminated or expired.
Displays the number of seconds before an idle SSH session is automatically disconnected. A change to the Timeout setting takes effect at the next login; it does not affect the current session.
Timeout Range : 0 or 60–10800 seconds. To disable the
Timeout feature, enter 0.
Default : 1800 seconds
Port used by CMC that listens for a server connection.
Configuration range: 10–65535
Default : 22
Using the CMC Web Interface 185
Table 5-53. Telnet Settings
Setting
Enabled
Max Sessions
Idle Timeout
Port Number
Description
Enables Telnet console interface on CMC.
Default : Unchecked (disabled)
Displays the maximum number of simultaneous Telnet sessions allowed for the chassis. A change to this property takes effect at the next login; it does not affect current
Active Sessions (including your own).
Allowed range : 1–4
Default : 4
NOTE: If you change the Max Sessions property to a value less than the current number of Active Sessions and then log out, you cannot log in again until the other sessions have been terminated or expired.
Displays the number of seconds before an idle Telnet session is automatically disconnected. A change to the
Timeout setting takes effect at the next login; it does not affect the current session.
Timeout Range : 0 or 60–10800 seconds. To disable the
Timeout feature, enter 0.
Default : 1800 seconds
Displays the port used by CMC that listens for a server connection.
Default : 23
186 Using the CMC Web Interface
Table 5-54. Remote RACADM Settings
Setting
Enabled
Max Sessions
Idle Timeout
Description
Enables the remote RACADM utility access to CMC.
Default : Checked (enabled)
Displays the maximum number of simultaneous RACADM sessions allowed for the chassis. A change to this property takes effect at the next login; it does not affect current
Active Sessions (including your own).
Allowed range : 1–4
Default : 4
NOTE: If you change the Max Sessions property to a value less than the current number of Active Sessions and then log out, you cannot log in again until the other sessions have been terminated or expired.
Displays the number of seconds before an idle racadm session is automatically disconnected. A change to the Idle
Timeout setting takes effect at the next login; it does not affect the current session. To disable the Idle Timeout feature, enter 0.
Timeout Range : 0, or 10 to 1920 seconds. To disable the
Timeout feature, enter 0.
Default: 30 seconds
Table 5-55. SNMP Configuration
Setting
Enabled
Community Name
Description
Enables SNMP on CMC.
Valid Values : Checked (enabled), unchecked (disabled)
Default : unchecked (disabled)
Displays the community string used to get data from
CMC's SNMP daemon.
Using the CMC Web Interface 187
Table 5-56. Remote Syslog Configuration
Setting
Enabled
Syslog Server 1
Syslog Server 2
Syslog Server 3
Syslog Port Number
Description
Enables the transmission and remote capture of CMC log and Hardware log entries to the specified server(s).
Valid values : Checked (enabled), unchecked (disabled)
Default : unchecked (disabled)
The first of three possible servers to host a copy of the CMC and hardware log entries. Specified as a Host
Name, an IPv6 address, or an IPv4 address.
The second of three possible servers to host a copy of the CMC and hardware log entries. Specified as a Host
Name, an IPv6 address, or an IPv4 address.
The third of three possible servers to host a copy of the CMC and hardware log entries. Specified as a Host
Name, an IPv6 address, or an IPv4 address.
Specifies the port number on the remote server for receiving a copy of CMC and hardware log entries. The same port number is used for all three servers. A valid syslog port number is in the 10-65535 range.
Default : 514
Configuring Power Budgeting
CMC allows you to budget and manage power to the chassis. The power management service optimizes power consumption and re-allocates power to different modules based on the demand.
For instructions on configuring power through CMC, see "Configuring and
For more information on CMC’s power management service, see "Power
188 Using the CMC Web Interface
Managing Firmware Updates
This section describes how to use the Web interface to update firmware.
The following Chassis components can be updated using the GUI or
RACADM commands:
• CMC — active and standby
• iKVM
• iDRAC
• IOM infrastructure devices
When you update firmware, there is a recommended process to follow that
can prevent a loss of service if the update fails. See "Installing or Updating the
CMC Firmware" on page 49 for guidelines to follow before you use the
instructions in this section.
Viewing the Current Firmware Versions
The Update page displays the current version of all the updatable components in the chassis. These may include the iKVM firmware, active
CMC firmware, (if applicable) the standby CMC firmware, the iDRAC firmware, and the IOM infrastructure device firmware. For more information
see "Updating the IOM Infrastructure Device Firmware" on page 193.
To open an update page for selected devices:
1 Click on the device name or select the Select/Deselect All check box.
2 Click Apply Update.
An update page for the selected devices displays.
If the chassis contains an earlier generation server whose iDRAC is in recovery mode or if CMC detects that iDRAC has corrupted firmware, then the earlier generation iDRAC is also listed on the Firmware Update page. See
"Recovering iDRAC Firmware Using CMC" on page 195 for the steps to
recover iDRAC firmware using CMC.
To view the chassis components that can be updated:
1
Log in to the Web interface. For more information, see "Accessing the
CMC Web Interface" on page 103.
2 Click Chassis Overview in the system tree.
3 Click the Update tab. The Firmware Update page appears.
Using the CMC Web Interface 189
190
To view the updatable server components:
1
Log in to the Web interface. For more information, see "Accessing the
CMC Web Interface" on page 103.
2 Click Server Overview in the system tree.
3 Click the Update tab. The Server Component Update appears.
Updating Firmware
NOTE: To update firmware on CMC, you must have Chassis Configuration
Administrator privilege.
NOTE: The firmware update retains the current CMC and iKVM settings.
NOTE: If a web user interface session is used to update system component firmware, the Idle Timeout setting must be set high enough to accommodate the file transfer time. In some cases, the firmware file transfer time may be as high
as 30 minutes. To set the Idle Timeout value, see "Configuring Services" on page 180.
The Firmware Update page displays the current version of the firmware for each listed component and allows you to update the firmware to the latest revision. The basic steps involved in updating device firmware are:
• Select the devices to update
• Click the Apply button below the grouping
• Click Browse to select the firmware image
• Click Begin Firmware Update to start the update process. A message that states Transferring file image is displayed, followed by a status progress page.
NOTE: Be sure you have the latest firmware version. You can download the latest firmware image file from the Dell Support website at support.dell.com.
Updating the CMC Firmware
NOTE: During updates of CMC firmware or iDRAC firmware on a server, some or all of the fan units in the chassis spins at 100%. This is normal.
NOTE: The Active CMC resets and becomes temporarily unavailable after the firmware has been uploaded successfully. If a standby CMC is present, the standby and active roles swap. The standby CMC becomes the active CMC. If an update is applied only to the active CMC, after the reset is complete the active CMC does not
Using the CMC Web Interface
run the updated image, only the standby CMC has that image. In general, it is highly recommended to maintain identical firmware versions for the active and standby
CMCs.
NOTE: To avoid disconnecting other users during a reset, notify authorized users who might log in to CMC and check for active sessions in the Sessions page. To open the Sessions page, select Chassis in the tree, click the Network tab, and then click the Sessions subtab. Help for that page is available through the Help link at the top right corner of the page.
NOTE: When transferring files to and from CMC, the file transfer icon spins during the transfer. If your icon is not animated, make sure that your browser is configured
to allow animations. See "Allow Animations in Internet Explorer" on page 39 for
instructions.
NOTE: If you experience problems downloading files from CMC using Internet
Explorer, enable the Do not save encrypted pages to disk option. See "Downloading
Files From CMC With Internet Explorer" on page 39 for instructions.
To update the CMC firmware:
1 On the Firmware Update page, select CMC or CMCs to update by selecting the Update Targets check box for CMC(s). Both CMCs can be updated at the same time.
2 Click the Apply CMC Update button below the CMC component list.
NOTE: The default CMC firmware image name is firmimg.cmc. CMC firmware should be updated first, before updating IOM infrastructure device firmware.
3 In the Firmware Image field, enter the path to the firmware image file on your management station or shared network, or click Browse to navigate to the file location.
4 Click Begin Firmware Update . The Firmware Update Progress section provides firmware update status information. A status indicator displays on the page while the image file uploads. File transfer time can vary greatly based on connection speed. When the internal update process begins, the page automatically refreshes and the Firmware update timer displays.
Additional instructions to follow:
• Do not use the Refresh button or navigate to another page during the file transfer.
• To cancel the process, click Cancel File Transfer and Update - this option is available only during file transfer.
Using the CMC Web Interface 191
192
• Update status displays in the Update State field; this field is automatically updated during the file transfer process.
NOTE: The update may take several minutes for CMC.
5 For a standby CMC, when the update is complete the Update State field displays "Done". For an active CMC, during the final phases of the firmware update process, the browser session and connection with CMC is lost temporarily as the active CMC is taken offline. You must log in again after a few minutes, when the active CMC has rebooted.
After CMC resets, the new firmware is displayed on the Firmware Update page.
NOTE: After the firmware update, clear the Web browser cache. See your Web browser’s online help for instructions on how to clear the browser cache.
Updating the iKVM Firmware
NOTE: The iKVM resets and becomes temporarily unavailable after the firmware has been uploaded successfully.
1 Log back in to CMC Web interface.
2 Select Chassis Overview in the system tree.
3 Click the Update tab. The Firmware Update page appears.
4 Select the iKVM to update by selecting the Update Targets check box for that iKVM.
5 Click the Apply iKVM Update button below the iKVM component list.
6 In the Firmware Image field, enter the path to the firmware image file on your management station or shared network, or click Browse to navigate to the file location.
NOTE: The default iKVM firmware image name is ikvm.bin; however, the iKVM firmware image name can be changed by the user to avoid confusion with previous images.
7 Click Begin Firmware Update .
8 Click Yes to continue. The Firmware Update Progress section provides firmware update status information. A status indicator displays on the page while the image file uploads. File transfer time can vary greatly based on connection speed. When the internal update process begins, the page automatically refreshes and the Firmware update timer displays.
Additional instructions to follow:
Using the CMC Web Interface
• Do not use the Refresh button or navigate to another page during the file transfer.
• To cancel the process, click Cancel File Transfer and Update - this option is available only during file transfer.
• Update status displays in the Update State field; this field is automatically updated during the file transfer process.
NOTE: The update may take up to two minutes for the iKVM.
When the update is complete, iKVM resets and the new firmware is displayed on the Firmware Update page.
Updating the IOM Infrastructure Device Firmware
By performing this update, the firmware for a component of the IOM device is updated, but not the firmware of the IOM device itself; the component is the interface circuitry between the IOM device and CMC. The update image for the component resides in the CMC file system, and the component displays as an updatable device on the CMC Web GUI only if the current revision on the component and the component image on CMC do not match.
1 Log back in to CMC Web interface.
2 Select Chassis Overview in the system tree.
3 Click the Update tab. The Firmware Update page appears.
4 Select the IOM device to update by selecting the Update Targets check box for that IOM device.
5 Click the Apply IOM Update button below the IOM component list.
NOTE: The Firmware Image field does not display for an IOM infrastructure device (IOMINF) target because the required image resides on CMC. CMC firmware should be updated first, before updating IOMINF firmware.
IOMINF updates are allowed by CMC if it detects that the IOMINF firmware is out-of-date with the image contained in CMC file system. If the IOMINF firmware is up-to-date, CMC prevents IOMINF updates.
Up-to-date IOMINF devices are be listed as updatable devices.
6 Click Begin Firmware Update . The Firmware Update Progress section provides firmware update status information. A status indicator displays on the page while the image file uploads. File transfer time can vary greatly
Using the CMC Web Interface 193
194 based on connection speed. When the internal update process begins, the page automatically refreshes and the Firmware update timer displays.
Additional instructions to follow:
• Do not use the Refresh button or navigate to another page during the file transfer.
• Update status displays in the Update State field; this field is automatically updated during the file transfer process.
NOTE: No file transfer timer is displayed when updating IOMINF firmware.
The update process may cause a brief loss of connectivity to the IOM device since the device performs a restart when the update is complete. When the update is complete, the new firmware is displayed and the updated system is no longer present on the Firmware Update page.
Updating the Server iDRAC Firmware
NOTE: The iDRAC (on a Server) resets and become temporarily unavailable after firmware updates have been uploaded successfully.
NOTE: The iDRAC firmware must be at version 1.4 or greater for servers with iDRAC, or 2.0 or greater for servers with iDRAC6 Enterprise.
1 Log back in to the CMC Web interface.
2 Select Chassis Overview in the system tree.
3 Click the Update tab. The Firmware Update page appears.
4 Select the iDRAC or iDRACs to update by selecting the Update Targets check box those devices.
5 Click the Apply iDRAC Update button below the iDRAC component list.
6 In the Firmware Image field, enter the path to the firmware image file on your management station or shared network, or click Browse to navigate to the file location.
7 Click Begin Firmware Update . The Firmware Update Progress section provides firmware update status information. A status indicator displays on the page while the image file uploads. File transfer time can vary greatly based on connection speed. When the internal update process begins, the page automatically refreshes and the firmware update timer displays.
Additional instructions to follow:
• Do not use the Refresh button or navigate to another page during the file transfer.
Using the CMC Web Interface
• To cancel the process, click Cancel File Transfer and Update - this option is available only during file transfer.
• Update status displays in the Update State field; this field is automatically updated during the file transfer process.
NOTE: The update may take several minutes for CMC or Server.
Recovering iDRAC Firmware Using CMC
iDRAC firmware is typically updated using iDRAC facilities such as the iDRAC Web interface, the SM-CLP command line interface, or operating system specific update packages downloaded from support.dell.com
. See the iDRAC Firmware User’s Guide for instructions for updating the iDRAC firmware.
Early generations of servers can have corrupted firmware recovered using the new update iDRAC firmware process. When CMC detects corrupted iDRAC firmware, it lists the server on the Firmware Update page.
Follow these steps to update the iDRAC firmware.
1 Download the latest iDRAC firmware to your management computer from support.dell.com
.
2
Log in to the Web interface (see "Accessing the CMC Web Interface" on page 103).
3 Click Chassis Overview in the system tree.
4 Click the Update tab. The Firmware Update page appears.
5 Select the iDRAC or iDRACs of the same model to update by selecting the
Update Targets check box those devices.
6 Click the Apply iDRAC Update button below the iDRAC component list.
7 Click Browse , browse to the iDRAC firmware image you downloaded, and click Open .
NOTE: The default iDRAC firmware image name is firmimg.imc. CMC firmware should be updated first, before updating IOM infrastructure device firmware.
8 Click Begin Firmware Update . Additional instructions to follow:
• Do not use the Refresh button or navigate to another page during the file transfer.
Using the CMC Web Interface 195
• To cancel the process, click Cancel File Transfer and Update - this option is available only during file transfer.
• Update status displays in the Update State field; this field is automatically updated during the file transfer process.
NOTE: It can take up to ten minutes to update the iDRAC firmware.
Managing iDRAC
CMC provides the Deploy iDRAC page to allow the user to configure installed and newly inserted server's iDRAC network configuration settings.
A user can configure one or more installed iDRAC devices from this page.
The user can also configure the default iDRAC network configuration settings and root password for severs that are installed later; these default settings are the iDRAC QuickDeploy settings.
For more information on the behaviour of iDRAC, see the iDRAC User’s
Guides on the Dell Support website at support.dell.com/manuals .
iDRAC QuickDeploy
The iDRAC QuickDeploy section of the Deploy iDRAC page contains network configuration settings that are applied to newly inserted servers.
You may use these settings to automatically populate the iDRAC Network
Settings table that is below the QuickDeploy section. Once QuickDeploy is enabled, the QuickDeploy settings are applied to servers when that server is
installed. See step 8 in "Configuring Networking Using the LCD
Configuration Wizard" on page 41 for more information on the iDRAC
QuickDeploy settings.
Follow these steps to enable and set the iDRAC QuickDeploy settings:
1 Log in to the CMC Web interface.
2 Select Server Overview in the system tree.
3 Click the Setup tab. The Deploy iDRAC page appears.
4 Set the QuickDeploy settings accordingly.
196 Using the CMC Web Interface
Table 5-57. QuickDeploy Settings
Setting Description
QuickDeploy Enabled Enables/disables the QuickDeploy feature that automatically applies the iDRAC settings configured on this page to newly inserted servers; the auto configuration must be confirmed locally on the LCD panel.
NOTE: This includes the root user password if the Set iDRAC
Root Password on Server Insertion box is checked.
Default : Unchecked (disabled)
Set iDRAC Root
Password on Server
Insertion
Specifies whether a server’s iDRAC root password should be changed to the value provided in the iDRAC Root
Password text box when the server is inserted. iDRAC Root Password When Set iDRAC Root Password on Server Insertion and
QuickDeploy Enabled are checked, this password value is assigned to a server's iDRAC root user password when the server is inserted into chassis. The password can have 1 to
20 printable (including spaces) characters.
Confirm iDRAC Root
Password
Verifies the password entered into the iDRAC Root
Password field.
Enable iDRAC LAN Enables/disables the iDRAC LAN channel.
Default: Unchecked (disabled)
Enable iDRAC IPv4 Enables/disables IPv4 on iDRAC. Default setting is enabled.
Enable iDRAC IPMI over LAN
Enables/disables the IPMI over LAN channel for each iDRAC present in the chassis.
Default: Unchecked (disabled)
Enable iDRAC DHCP Enables/disables DHCP for each iDRAC present in the chassis. If this option is enabled, the fields QuickDeploy IP,
QuickDeploy Subnet Mask , and QuickDeploy Gateway are disabled, and can not be modified since DHCP is used to automatically assign these settings for each iDRAC.
Default: Unchecked (disabled)
Using the CMC Web Interface 197
198
Table 5-57. QuickDeploy Settings (continued)
Setting Description
Starting iDRAC IPv4
Address (Slot 1)
Specifies the static IP address of the iDRAC of the server in slot 1 of the enclosure. The IP address of each subsequent iDRAC is incremented by 1 for each slot from slot 1's static
IP address. In the case where the IP address plus the slot number is greater than the subnet mask, an error message is displayed.
NOTE: The subnet mask and the gateway are not incremented like the IP address.
For example, if the starting IP address is 192.168.0.250 and the subnet mask is 255.255.0.0 then the QuickDeploy
IP address for slot 15 is 192.168.0.265. If the subnet mask were 255.255.255.0, the QuickDeploy IP address range is not fully within QuickDeploy
Subnet error message is displayed when either the Save
QuickDeploy Settings or Auto-Populate Using
QuickDeploy Settings buttons are pressed.
iDRAC IPv4 Netmask Specifies the QuickDeploy subnet mask that is assigned to all newly inserted servers.
iDRAC IPv4 Gateway Specifies the QuickDeploy default gateway that is assigned to all iDRAC present in the chassis.
Enable iDRAC IPv6 Enables IPv6 addressing for each iDRAC present in the chassis that is IPv6 capable.
Enable iDRAC IPv6
Autoconfiguration
Enables the iDRAC to obtain IPv6 settings (Address and prefix length) from a DHCPv6 server and also enables stateless address auto configuration. Default setting is enabled.
iDRAC IPv6 Gateway Specifies the default IPv6 gateway to be assigned to the iDRACs. Default setting is "::".
iDRAC IPv6 Prefix
Length
Specifies the prefix length to be assigned for the
IPv6 addresses on the iDRAC. Default setting is 64.
5 To save the selections click the Save QuickDeploy Settings button. If you made changes to the iDRAC network setting, click the Apply iDRAC
Network Settings button to deploy the settings to the iDRAC.
Using the CMC Web Interface
6 To update the table to the last saved QuickDeploy settings, and restore the iDRAC Network settings to the current values for each installed server, click Refresh .
NOTE: Clicking the Refresh button deletes all iDRAC QuickDeploy and iDRAC
Network configuration settings that have not been saved.
The QuickDeploy feature only executes when it is enabled, and a server is inserted in the chassis. If Set iDRAC Root Password on Server Insertion and
QuickDeploy Enabled are checked, the user is prompted using the LCD interface to allow or not allow the password change. If there are network configuration settings that differ from the current iDRAC settings, the user is prompted to either accept or not accept the changes.
NOTE: When there is a LAN or IPMI over LAN difference, the user is prompted to accept the QuickDeploy IP address setting. If the difference is the DHCP setting, the user is prompted to accept the DHCP QuickDeploy setting.
To copy the QuickDeploy settings into the iDRAC Network Settings section, click Auto-Populate Using QuickDeploy Settings . The QuickDeploy network configurations settings are copied into the corresponding fields in the iDRAC
Network Configuration Settings table.
NOTE: Changes made to QuickDeploy fields are immediate, but changes made to one or more iDRAC server network configuration settings may require a couple of minutes to propagate from CMC to iDRAC. Pressing the Refresh button too soon may display only partially correct data for one or more iDRAC servers.
Using the CMC Web Interface 199
iDRAC Network Settings
The iDRAC Network Settings section of the Deploy iDRAC page contains a table listing all installed server’s iDRAC IPv4 and IPv6 network configuration settings. Using this table you can configure the iDRAC network configurations settings for each installed server. The initial values displayed for each of the fields are the current values read from the iDRAC. Changing a field and clicking Apply iDRAC Network Settings saves the changed field to the iDRAC. Follow these steps to enable and set the iDRAC Network
Settings :
1 Log in to the CMC Web interface.
2 Select Server Overview in the system tree.
3 Click the Setup tab.
The Deploy iDRAC page appears.
4 Select the check box for QuickDeploy Enabled to enable the
QuickDeploy settings.
5 Set the remaining iDRAC Network Settings accordingly.
Table 5-58. iDRAC Network Settings
Setting
Slot
Name
Enable LAN
Description
Displays the slot occupied by the server in the chassis.
Slot numbers are sequential IDs, from 1 to 16 (there are 16 slots available on the chassis), that help identify the location of the server in the chassis.
NOTE: When there are fewer than 16 servers occupying slots, only those slots populated by servers are displayed.
Displays the server name of the server in each slot.
By default, the slots are named SLOT-01 to SLOT-16 .
NOTE: The slot name cannot be blank or NULL.
Enables (checked) or disables (unchecked) the LAN channel.
NOTE: When LAN is not selected (disabled), all other network configuration settings, (IPMI over LAN, DHCP, IP Address
Subnet Mask and Gateway) are not used. These fields are not accessible.
200 Using the CMC Web Interface
Table 5-58. iDRAC Network Settings (continued)
Setting Description
Change Root Password Enables (when checked) the ability to change the password of the iDRAC root user. The iDRAC Root Password and
Confirm iDRAC Root Password fields must be provided for this operation to be successful.
DHCP If selected DHCP is used to acquire the iDRAC IP address, subnet mask and default gateway, otherwise the values defined in the iDRAC network configuration fields are used. LAN must be enabled to set this field
IPMI over LAN
IP Address
Subnet Mask
Gateway
Enable IPv4
Enables (checked) or disables (unchecked) the IPMI LAN channel. LAN must be enabled to set this field.
The static IPv4 or IPv6 address assigned to the iDRAC located in this slot.
Specifies the subnet mask assigned to the iDRAC installed in this slot.
Specifies the default gateway assigned to the iDRAC which is installed in this slot.
Enables the iDRAC in the slot to use the IPv4 protocol on the network. You must select the Enable LAN option for this option to be active. Default setting is enabled.
Enable IPv6 Enables the iDRAC in the slot to use the IPv6 protocol on the network. You must select the Enable LAN option and clear the Autoconfiguration option for this option to be active. Default setting is disabled.
NOTE: This option is available only if the server is
IPv6 capable.
Autoconfiguration
Prefix Length
Enables the iDRAC to obtain IPv6 settings (Address and prefix length) from a DHCPv6 server and also enables stateless address auto configuration.
NOTE: This option is available only if the server is
IPv6 capable.
Specifies the length, in bits, of the IPv6 subnet to which this iDRAC belongs.
Using the CMC Web Interface 201
202
6 To deploy the setting to iDRAC, click Apply iDRAC Network Settings button. If you made changes to the QuickDeploy settings, they are also saved.
7 To restore the iDRAC Network settings to the current values for each installed server, and update the QuickDeploy table to the last saved
QuickDeploy settings click Refresh .
NOTE: Clicking Refresh button deletes all iDRAC QuickDeploy and iDRAC
Network configuration settings that have not been saved.
The iDRAC Network Settings table reflects future network configuration settings; the values shown for installed servers may or may not be the same as the currently installed iDRAC network configuration settings. Press the
Refresh button to update the iDRAC Deploy page with each installed iDRAC network configuration settings after changes are made.
NOTE: Changes made to QuickDeploy fields are immediate, but changes made to one or more iDRAC server network configuration settings may require a couple of minutes to propagate from CMC to iDRAC. Pressing the Refresh button too soon may display only partially correct data for a one or more iDRAC servers.
Launching Remote Console from CMC GUI
This feature allows you to launch a Keyboard-Video-Mouse (KVM) session directly on the server.
To launch a server remote console from the CMC GUI Homepage:
1 Click on the specified server in the chassis graphic.
2 On Quicklinks , click the Launch Remote Console link.
To launch a server remote console from the Servers Status page:
1 On System tree, select Server Overview .
2 Click Launch Remote Console in the table for the specified server.
To launch a server Remote Console for an individual:
1 Expand Server Overview in the system tree. All servers (1–16) appear in the expanded servers list.
2 In the system tree, click the server you want to view. The Server Status page appears.
3 Click Launch Remote Console .
Using the CMC Web Interface
The remote console feature is supported only when all of the following conditions are met:
• The chassis power is on.
• Server is PowerEdge M610, M610X, M710, M710HD, or M910.
• The LAN interface on the server is enabled.
• The iDRAC version is 2.20 or later.
• The host system is installed with JRE (Java Runtime Environment) 6
Update 16 or later.
• The browser on host system allows pop-up windows (pop-up blocking is disabled).
NOTE: Remote Console can also be launched from the iDRAC GUI. See iDRAC GUI for more details.
Launching iDRAC using Single Sign-On
CMC provides limited management of individual chassis components, such as servers. For complete management of these individual components, CMC provides a launch point for the server’s management controller (iDRAC)
Web-based interface.
To launch the iDRAC management console from the Servers page:
1 Log in to the CMC Web interface.
2 Select Server Overview in the system tree. The Servers Status page appears.
3 Click the Launch iDRAC GUI button for the server you want to manage.
To launch the iDRAC management console for an individual server:
1 Log in to the CMC Web interface.
2 Expand Server Overview in the system tree. All of the servers (1–16) appear in the expanded Servers list.
3 Click the server you want to view. The Server Status page displays.
4 Click the Launch iDRAC GUI button.
Using the CMC Web Interface 203
A user may be able to launch iDRAC GUI without having to login a second time, as this feature utilizes single sign-on. Single sign-on policies are described below.
• A CMC user who has server administrative privilege, is automatically logged into iDRAC using single sign-on. Once on the iDRAC site, this user is automatically granted Administrator privileges. This is true even if the same user does not have an account on iDRAC, or if the account does not have the Administrator’s privileges.
• A CMC user who does NOT have the server administrative privilege, but has the same account on iDRAC is automatically logged into iDRAC using single sign-on. Once on the iDRAC site, this user is granted the privileges that were created for the iDRAC account.
• A CMC user who does not have the server administrative privilege, or the same account on the iDRAC, does NOT automatically logged into iDRAC using single sign-on. This user is directed to the iDRAC login page when the Launch iDRAC GUI button is clicked.
NOTE: The term "the same account" in this context means that the user has the same login name with a matching password for CMC and for iDRAC. The user who has the same login name without a matching password, is considered to have the same account.
NOTE: Users may be prompted to log in to iDRAC (see the third Single Sign-on policy bullet above).
NOTE: If the iDRAC network LAN is disabled (LAN Enabled = No), single sign-on is not available.
NOTE: If the server is removed from the chassis, the iDRAC IP address is changed, or the iDRAC network connection experiences a problem, then clicking the Launch iDRAC GUI icon may display an error page.
204 Using the CMC Web Interface
FlexAddress
This section describes the FlexAddress Web interface screens. FlexAddress is an optional upgrade that allows server modules to replace the factoryassigned WWN/MAC ID with a WWN/MAC ID provided by the chassis.
NOTE: You must purchase and install the FlexAddress upgrade to have access to the configuration screens. If the upgrade has not been purchased and installed, the following text is displayed on the Web interface:
Optional feature not installed. See the Dell
Chassis Management Controller Users Guide for information on the chassis-based WWN and MAC address administration feature.
To purchase this feature, please contact Dell at www.dell.com.
Viewing FlexAddress Status
You can use the Web interface to view FlexAddress status information. You can view status information for the entire chassis or for an individual server.
The information displayed includes:
• Fabric configuration.
• FlexAddress active/not active.
• Slot number and name.
• Chassis-assigned and server-assigned addresses.
• Addresses in use.
NOTE: You can also view FlexAddress status using the command line interface.
For more command information, see "Using FlexAddress" on page 217.
Viewing Chassis FlexAddress Status
FlexAddress status information can be displayed for the entire chassis.
The status information includes whether the feature is active and an overview of the FlexAddress status for each server.
Using the CMC Web Interface 205
206
To view whether FlexAddress is active for the chassis:
1
Log in to the Web interface (see "Accessing the CMC Web Interface" on page 103).
2 Click Chassis Overview in the system tree.
3 Click the Setup tab. The General Setup page appears. The FlexAddress entry has a value of Active or Not Active ; a value of active means that the feature is installed on the chassis. A value of not active means that the feature is not installed and not in use on the chassis.
To display a FlexAddress status overview for each server module:
1
Log in to the Web interface ("Accessing the CMC Web Interface" on page 103).
2 Click Server Overview ï‚® Properties ï‚® WWN/MAC .
3 The FlexAddress Summary page is displayed. This page allows you to view the WWN configuration and MAC addresses for all slots in the chassis.
The status page presents the following information:
Fabric
Configuration
WWN/MAC
Addresses
Fabric A , Fabric B , and Fabric C display the type of the
Input/Output fabric installed. iDRAC displays the server management MAC address.
NOTE: If Fabric A is enabled, unpopulated slots display chassisassigned MAC addresses for Fabric A and MAC or WWNs for
Fabrics B and C if they are in use by populated slots.
Displays FlexAddress configuration for each slot in the chassis.
Information displayed includes:
• iDRAC management controller is not a fabric but its
FlexAddress is treated like one.
• Slot number and location
• FlexAddress active/not active status
• Fabric type
• Server-assigned and chassis-assigned WWN/MAC addresses in use
A green check mark indicates the active address type, either server-assigned or chassis-assigned.
4 For additional information, click Help .
Using the CMC Web Interface
Viewing Server FlexAddress Status
FlexAddress status information can also be displayed for each individual server. The server level information displays a FlexAddress status overview for that server.
To view FlexAddress server information:
1
Log in to the Web interface (see "Accessing the CMC Web Interface" on page 103).
2 Expand Server Overview in the system tree. All of the servers (1–16) appear in the expanded Servers list.
3 Click the server you want to view.
The Server Status page displays.
4 Click the Setup tab, and the FlexAddress subtab. The Deploy FlexAddress page is displayed. This page allows you to view the WWN configuration and MAC addresses for the selected server.
The status page presents the following information:
Table 5-59. Status Page Information
FlexAddress
Enabled
Current State
Power State
Displays whether the FlexAddress feature is active or not active for the particular slot.
Displays the current FlexAddress configuration:
• Chassis-Assigned - selected slot address is chassis assigned using the FlexAddress. The slot-based WWN/MAC addresses remain the same even if a new server is installed.
• Server-Assigned - server uses the server-assigned address or the default address embedded into the controller hardware.
Displays the current power status of the servers; values are: On,
Powering On, Powering Off, Off , and N/A (if a server is not present).
Using the CMC Web Interface 207
208
Table 5-59. Status Page Information
Health OK
Informational Displays information about FlexAddress when no change in health status
(OK, Warning, Critical) has occurred.
Warning Indicates that only warning alerts have been issued, and c orrective action must be taken.
If corrective actions are not taken, then critical failures that can affect the integrity of the server could occur.
Critical
Indicates that FlexAddress is present and providing status to CMC. In the event of a communication failure between CMC and FlexAddress, CMC cannot obtain or display health status for FlexAddress.
No Value
Indicates that at least one Failure alert has been issued. Critical status represents a system failure on the server, and corrective action must be taken immediately .
When FlexAddress is absent, health information is not provided.
iDRAC firmware Displays the iDRAC version currently installed on the server.
BIOS Version Displays the current BIOS version of the server module.
Slot
Location
Slot number of the server associated with the fabric location.
Displays the location of the Input/Output (I/O) module in the chassis by group number (A, B, or C) and slot number (1 or 2).
Slot names: A1, A2, B1, B2, C1, or C2.
Fabric Displays the type of fabric.
Server-Assigned Displays the server-assigned WWN/MAC addresses that are embedded in the controller's hardware.
Chassis-Assigned Displays the chassis-assigned WWN/MAC addresses that are used for the particular slot.
5 For additional information, click Help .
Using the CMC Web Interface
Configuring FlexAddress
If you purchase FlexAddress with your chassis, is installed and active when you power up your system. If you purchase FlexAddress separately, you must install the SD feature card using the instructions in the Chassis Management
Controller (CMC) Secure Digital (SD) Card Technical Specification document. See support.dell.com/manuals for this document.
The server must be off before you begin configuration. You can enable or disable FlexAddress on a per fabric basis. Additionally, you can enable/disable the feature on a per slot basis. After you enable the feature on a per-fabric basis, you can then select slots to be enabled. For example, if Fabric-A is enabled, any slots that are enabled have FlexAddress enabled only on Fabric-
A. All other fabrics use the factory-assigned WWN/MAC on the server.
Selected slots have FlexAddress enabled for all fabrics that are enabled.
For example, it is not possible to enable Fabric-A and B, and have Slot 1 be
FlexAddress enabled on Fabric-A but not on Fabric-B.
NOTE: You can also configure FlexAddress using the command line interface.
For more command information, see "Using FlexAddress" on page 217.
Chassis-Level Fabric and Slot FlexAddress Configuration
At the chassis level, you can enable or disable the FlexAddress feature for fabrics and slots. FlexAddress is enabled on a per-fabric basis and then slots are selected for participation in the feature. Both fabrics and slots must be enabled to successfully configure FlexAddress.
Perform the following steps to enable or disable fabrics and slots to use the
FlexAddress feature:
1
Log on to the Web interface (see "Accessing the CMC Web Interface" on page 103).
2 Click Server Overview in the system tree.
3 Click the Setup tab ï‚®ï€ FlexAddress subtab. The Deploy FlexAddress page is displayed.
4 The Select Fabrics for Chassis-Assigned WWN/MACs displays a check box for Fabric A , Fabric B, Fabric C , and iDRAC.
5 Click the check box for each fabric you want to enable FlexAddress on.
To disable a fabric, click the check box to clear the selection.
Using the CMC Web Interface 209
NOTE: If no fabrics are selected, FlexAddress is not be enabled for the selected slots.
The Select Slots for Chassis-Assigned WWN/MACs page displays an
Enabled check box for each slot in the chassis (1 - 16).
6 Click the Enabled check box for each slot you want to enable FlexAddress on. If you want to select all slots, use the Select/Deselect All check box.
To disable a slot, click the Enabled check box to clear the selection.
NOTE: If a server is present in the slot, it needs to be powered off before the FlexAddress feature can be enabled on that slot.
NOTE: If no slots are selected, FlexAddress is not be enabled for the selected fabrics.
7 Click Apply to save the changes .
For additional information, click Help .
Server-Level Slot FlexAddress Configuration
At the server level, you can enable or disable the FlexAddress feature for individual slots.
To enable or disable an individual slot to use the FlexAddress feature:
1
Log in to the Web interface (see "Accessing the CMC Web Interface" on page 103).
2 Expand Server Overview in the system tree. All of the servers (1–16) appear in the expanded Servers list.
3 Click the server you want to view. The Server Status page displays.
4 Click the Setup tab, and the FlexAddress subtab. The FlexAddress Status page is displayed.
5 Use the pull down menu for FlexAddress Enabled to make your selection; select Yes to enable FlexAddress or select No to disable FlexAddress.
6 Click Apply to save the changes. For additional information, click Help.
210 Using the CMC Web Interface
Remote File Sharing
The Remote Virtual Media File Share option maps a file from a share drive on the network to one or more servers through CMC to deploy or update an operating system. When connected, the remote file is accessible as if it is on the local system. Two types of media are supported: floppy drives and
CD/DVD drives.
1
Log in to the Web interface (see "Accessing the CMC Web Interface" on page 103).
2 Click Server Overview in the system tree.
3 Click the Setup tab, and the Remote File Sharing subtab. The Deploy
Remote File Share page is displayed.
4 Set the Remote File Sharing settings.
Table 5-60. Remote File Sharing Settings
Setting Description
Image File Path Image File Path is only needed for connect and deploy operations. It does not apply to disconnect operations. The path name of the network drive is mounted to the server through a Windows SMB or
Linux/Unix NFS protocol.
For example, to connect to CIFS:
// <IP to connect for CIFS file system>/<file path>/<image name>
To connect to NFS:
// <IP to connect for NFS file system>:/<file path>/<image name>
File names that end with .img
are connected as virtual floppies. File names that end with .iso
are connected as virtual CD/DVDs. The maximum number of characters is 511.
User Name
Password
User Name is only needed for connect and deploy operations.
It does not apply to disconnect operations. The maximum number of characters you can specify in this field is 40.
Password is only needed for connect and deploy operations. It does not apply to disconnect operations. The maximum number of characters you can specify in this field is 40.
Using the CMC Web Interface 211
212
Table 5-60. Remote File Sharing Settings (continued)
Setting Description
Slot
Name
Model
Power State
Identifies the location of the slot. Slot numbers are sequential from
1 to 16 (for the 16 available slots in the chassis).
Displays the name of the slot. Slots are named depending on their position in the chassis.
Displays the model name of the server.
Displays the power status of the server:
N/A – CMC has not yet determined the power state of the server.
Off – Either the server is off or the chassis is off.
On – Both the chassis and the server are on.
Powering On – Temporary state between Off and On. On success, the Power State is On.
Powering Off – Temporary state between On and Off. On success, the Power State is Off.
Connect Status Displays the remote file share connection status.
Select/Deselect
All
Select this option before initiating a remote file share operation.
Remote file share operations are: Connect, Disconnect, and Deploy.
5 Click Connect to connect to a remote file share. To connect a remote file share, you must provide the path, user name, and password. A successful operation allows access to the media.
Click Disconnect to disconnect a previously connected remote file share.
Click Deploy to deploy the media device.
NOTE: Save all working files before executing the D eploy command because this action causes the server to be restarted.
This command involves these actions:
– The remote file share is connected.
– The file is selected as the first boot device for the servers.
– The server is restarted.
– Power is applied to the server if the server is turned off.
Using the CMC Web Interface
Frequently Asked Questions
Table 5-61 lists the frequently asked questions while managing or recovering
a remote system.
.
Table 5-61. Managing and Recovering a Remote System
Question Answer
When accessing the CMC Web interface, I get a security warning stating the host name of the SSL certificate does not match the host name of CMC.
CMC includes a default CMC server certificate to ensure network security for the Web interface and remote RACADM features. When this certificate is used, the Web browser displays a security warning because the default certificate is issued to
CMC default certificate which does not match the host name of CMC (for example, the IP address).
To address this security concern, upload a CMC server certificate issued to the IP address of CMC.
When generating the certificate signing request
(CSR) to be used for issuing the certificate, ensure that the common name (CN) of the CSR matches the IP address of CMC (for example,
192.168.0.120) or the registered DNS CMC name.
To ensure that the CSR matches the registered
DNS CMC name:
1 In the System tree, click Chassis Overview.
2 Click the Network tab, and then click Network .
The Network Configuration page appears.
3
4
5
Select the Register CMC on DNS check box.
Enter the CMC name In the DNS CMC
Name field.
Click Apply Changes .
For more information about generating CSRs and
issuing certificates, see "Securing CMC
Communications Using SSL and Digital
Using the CMC Web Interface 213
Table 5-61. Managing and Recovering a Remote System (continued)
Question Answer
Why are the remote RACADM and Web-based services unavailable after a property change?
Why doesn’t my DNS server register my CMC?
When accessing the CMC Web interface, I get a security warning stating the SSL certificate was issued by a certificate authority that is not trusted.
It may take a minute for the remote RACADM services and the Web interface to become available after the CMC Web server resets.
The CMC Web server is reset after the following occurrences:
• When changing the network configuration or network security properties using the CMC Web user interface
• When the cfgRacTuneHttpsPort property is changed (including when a config -f < config file > changes it)
• When racresetcfg is used or a chassis configuration backup is restored.
• When CMC is reset
• When a new SSL server certificate is uploaded
Some DNS servers only register names of
31 characters or fewer.
CMC includes a default CMC server certificate to ensure network security for the Web interface and remote RACADM features. This certificate is not issued by a trusted certificate authority. To address this security concern, upload a CMC server certificate issued by a trusted certificate authority
(such as Thawte or Verisign). For more information about issuing certificates, see
"Securing CMC Communications Using SSL and
Digital Certificates" on page 173.
214 Using the CMC Web Interface
Table 5-61. Managing and Recovering a Remote System (continued)
Question
The following message is displayed for unknown reasons:
Remote Access: SNMP
Authentication Failure
Why does this happen?
Answer
As part of discovery, IT Assistant attempts to verify the device’s get and set community names. In IT
Assistant, you have the get community name = public and the set community name = private.
By default, the community name for the CMC agent is public. When IT Assistant sends out a set request, the CMC agent generates the SNMP authentication error because it only accepts requests from community = public .
You can change the CMC community name using
RACADM.
To see the CMC community name, use the following command: racadm getconfig -g cfgOobSnmp
To set the CMC community name, use the following command: racadm config -g cfgOobSnmp -o cfgOobSnmpAgentCommunity
< community name >
To prevent SNMP authentication traps from being generated, you must input community names that are accepted by the agent. Since CMC only allows one community name, you must input the same get and set community name for IT Assistant discovery setup.
Troubleshooting CMC
The CMC Web interface provides tools for identifying, diagnosing, and fixing problems with your chassis. For more information about
troubleshooting, see "Troubleshooting and Recovery."
Using the CMC Web Interface 215
216 Using the CMC Web Interface
6
Using FlexAddress
The FlexAddress feature is an optional upgrade that allows server modules to replace the factory-assigned World Wide Name and Media Access Control
(WWN/MAC) network IDs with WWN/MAC IDs provided by the chassis.
Every server module is assigned unique WWN and/or MAC IDs as part of the manufacturing process. Before FlexAddress, if you had to replace one server module with another, the WWN/MAC IDs would change and Ethernet network management tools and SAN resources would need to be reconfigured to be aware of the new server module.
FlexAddress allows CMC to assign WWN/MAC IDs to a particular slot and override the factory IDs. If the server module is replaced, the slot-based
WWN/MAC IDs remain the same. This feature eliminates the need to reconfigure Ethernet network management tools and SAN resources for a new server module.
Additionally, the override action only occurs when a server module is inserted in a FlexAddress enabled chassis; no permanent changes are made to the server module. If a server module is moved to a chassis that does not support
FlexAddress, the factory-assigned WWN/MAC IDs is used.
Before installing FlexAddress, you can determine the range of MAC addresses contained on a FlexAddress feature card by inserting the SD card into an
USB Memory Card Reader and viewing the file pwwn_mac.xml
. This clear text XML file on the SD card contains an XML tag mac_start that is the first starting hex MAC address that is used for this unique MAC address range.
The mac_count tag is the total number of MAC addresses that the SD card allocates. The total MAC range allocated can be determined by:
< mac_start > + 0xCF (208 - 1) = mac_end where 208 is the mac_count and the formula is
<mac_start> + <mac_count> - 1 = <mac_end>
For example:(starting_mac)00188BFFDCFA + 0xCF =
(ending_mac)00188BFFDDC9.
NOTE: Lock the SD card prior to inserting in the USB "Memory Card Reader" to prevent accidently modifying any of the contents. You before inserting into CMC.
must unlock the SD card
217 Using FlexAddress
218
Activating FlexAddress
FlexAddress is delivered on a Secure Digital (SD) card that must be inserted into CMC to activate the feature. To activate the FlexAddress feature, software updates may be required; if you are not activating FlexAddress these updates are not required . The updates, which are listed in the table below, include server module BIOS, I/O mezzanine BIOS or firmware, and CMC firmware. You must apply these updates before you enable FlexAddress.
If these updates are not applied, the FlexAddress feature may not function as expected.
Component
Ethernet Mezzanine card - Broadcom
M5708t, 5709, 5710
Minimum required version
Boot code firmware 4.4.1 or later iSCSI boot firmware 2.7.11 or later
PXE firmware 4.4.3 or later
BIOS 2.04 or later FC Mezzanine card - QLogic QME2472,
FC8
FC Mezzanine card - Emulex LPe1105-
M4, FC8
Server Module BIOS
BIOS 3.03a3 and firmware 2.72A2 or later
PowerEdge M600 – BIOS 2.02 or later
PowerEdge M605 – BIOS 2.03 or later
PowerEdge M805
PowerEdge M905
PowerEdge M610
PowerEdge M710
PowerEdge M710hd
PowerEdgeM600/M605 LAN on motherboard (LOM) iDRAC
CMC
Boot code firmware 4.4.1 or later iSCSI boot firmware 2.7.11 or later
Version 1.50 or later for PowerEdge xx 0 x systems
Version 2.10 or later for PowerEdge xx 1 x systems
Version 1.10 or later
Using FlexAddress
NOTE: Any system ordered after June 2008 has the correct firmware versions.
To ensure proper deployment of the FlexAddress feature, update the BIOS and the firmware in the following order:
1 Update all mezzanine card firmware and BIOS.
2 Update server module BIOS.
3 Update iDRAC firmware on the server module.
4 Update all CMC firmware in the chassis; if redundant CMCs are present, ensure both are updated.
5 Insert the SD card into the passive module for a redundant CMC module system or into the single CMC module for a non-redundant system.
NOTE: If CMC firmware that supports FlexAddress (version 1.10 or later) is not installed, the feature is not activated.
See the Chassis Management Controller (CMC) Secure Digital (SD) Card
Technical Specification document for SD card installation instructions.
NOTE: The SD card contains a FlexAddress feature. Data contained on the SD card is encrypted and may not be duplicated or altered in any way as it may inhibit system function and cause the system to malfunction.
NOTE: Your use of the SD card is limited to one chassis only. If you have multiple chassis, you must purchase additional SD cards.
Activation of the FlexAddress feature is automatic on restart of CMC with the SD feature card installed; this activation causes the feature to bind to the current chassis. If you have the SD card installed on the redundant CMC, activation of the FlexAddress feature does not occur until the redundant
CMC is made active. See the Chassis Management Controller (CMC) Secure
Digital (SD) Card Technical Specification document for information on how to make a redundant CMC active.
When CMC restarts, verify the activation process by using the steps in the
next section, "Verifying FlexAddress Activation" on page 220.
Using FlexAddress 219
Verifying FlexAddress Activation
To ensure proper activation of FlexAddress, RACADM commands can be used to verify the SD feature card and FlexAddress activation.
Use the following RACADM command to verify the SD feature card and its status: racadm featurecard -s
Table 6-1. Status Messages Returned by featurecard -s Command
Status Message Actions
No feature card inserted.
Check CMC to verify that the SD card was properly inserted. In a redundant
CMC configuration, ensure that the CMC with the SD feature card installed is the active
CMC and not the standby CMC.
The feature card inserted is valid and contains the following feature(s)
FlexAddress: The feature card is bound to this chassis.
No action required.
The feature card inserted is valid and contains the following feature(s)
FlexAddress: The feature card is bound to another chassis, svctag = ABC1234, SD card
SN = 01122334455
Remove the SD card; locate and install the SD card for the current chassis.
The feature card inserted is valid and contains the following feature(s)
FlexAddress: The feature card is not bound to any chassis.
The feature card can be moved to another chassis or can be reactivated on the current chassis.To reactivate on the current chassis, enter racadm racreset until the
CMC module with the feature card installed becomes active.
Use the following RACADM command to display all activated features on the chassis: racadm feature -s
220 Using FlexAddress
The command returns the following status message:
Feature = FlexAddress
Date Activated = 8 April 2008 - 10:39:40
Feature installed from SD-card SN = 01122334455
If there are no active features on the chassis, the command returns a message: racadm feature -s
No features active on the chassis.
Dell Feature Cards may contain more than one feature. Once any feature included on a Dell Feature Card has been activated on a chassis, any other features that may be included on that Dell Feature Card cannot be activated on a different chassis. In this case, the racadm feature -s command displays the following message for the affected features:
ERROR: One or more features on the SD card are active on another chassis.
For further information on the RACADM commands, see the feature and featurecard command sections of the Command Line Reference Guide for iDRAC6 and CMC .
Deactivating FlexAddress
The FlexAddress feature can be deactivated and the SD card returned to a pre-installation state using a RACADM command. There is no deactivation function within the Web interface. Deactivation returns the SD card to its original state where it can be installed and activated on a different chassis.
NOTE: The SD card must be physically installed in CMC, and the chassis must be powered-down before executing the deactivation command.
If you execute the deactivation command with no card installed, or with a card from a different chassis installed, the feature is deactivated and no change is made to the card.
Using FlexAddress 221
222
Deactivating FlexAddress
Use the following RACADM command to deactivate the FlexAddress feature and restore the SD card: racadm feature -d -c flexaddress
The command returns the following status message upon successful deactivation: feature FlexAddress is deactivated on the chassis successfully.
If the chassis is not powered-down prior to execution, the command fails with the following error message:
ERROR: Unable to deactivate the feature because the chassis is powered ON
For further information on the command, see the feature command section of the Command Line Reference Guide for iDRAC6 and CMC .
Configuring FlexAddress Using the CLI
NOTE: You must enable both—the slot and fabric— for the chassis-assigned
MAC address to be pushed to the iDRAC.
NOTE: You can also view FlexAddress status using the graphical user interface.
For more information, see "FlexAddress" on page 205.
You can use the command line interface to enable or disable FlexAddress on a per fabric basis. Additionally, you can enable/disable the feature on a per slot basis. After you enable the feature on a per-fabric basis, you can then select slots to be enabled. For example, if only Fabric-A is enabled, any slots that are enabled have FlexAddress enabled only on Fabric-A. All other fabrics use the factory-assigned WWN/MAC on the server. For this feature to work, the fabric must be enabled and the server must be powered off.
Enabled slots are FlexAddress enabled for all fabrics that are enabled.
For example, it is not possible to enable Fabric-A and B, and have Slot 1 be
FlexAddress enabled on Fabric-A but not on Fabric-B.
Use the following RACADM command to enable or disable fabrics: racadm setflexaddr [-f <fabricName> <state>]
<fabricName> = A, B, C, or iDRAC
Using FlexAddress
<state> = 0 or 1
Where 0 is disable and 1 is enable.
Use the following RACADM command to enable or disable slots: racadm setflexaddr [-i <slot#> <state>]
<slot#> = 1 to 16
<state> = 0 or 1
Where 0 is disable and 1 is enable.
For additional information on the command, see the setflexaddr command section of the Command Line Reference Guide for iDRAC6 and
CMC .
Additional FlexAddress Configuration for Linux
When changing from a server-assigned MAC ID to chassis-assigned
MAC ID on Linux-based operating systems, additional configuration steps may be required:
• SUSE Linux Enterprise Server 9 and 10: You may need to run YAST
(Yet another Setup Tool) on your Linux system to configure your network devices and then restart the network services.
• Red Hat Enterprise Linux 4 and Red Hat Enterprise Linux 5: Run Kudzu, a utility to detect and configure new/changed hardware on the system.
Kudzu presents you with The Hardware Discovery Menu; it detects the
MAC address change as hardware was removed and new hardware added.
Viewing FlexAddress Status Using the CLI
You can use the command line interface to view FlexAddress status information. You can view status information for the entire chassis or for a particular slot. The information displayed includes:
• Fabric configuration
• FlexAddress enabled/disabled
• Slot number and name
• Chassis-assigned and server-assigned addresses
• Addresses in use
Using FlexAddress 223
Use the following RACADM command to display FlexAddress status for the entire chassis: racadm getflexaddr
To display FlexAddress status for a particular slot: racadm getflexaddr [-i <slot#>]
<slot#> = 1 to 16
See "Configuring FlexAddress Using the CLI" on page 222 for additional
details on FlexAddress configuration. For additional information on the command, see the getflexaddr command section of the Command Line
Reference Guide for iDRAC6 and CMC .
Configuring FlexAddress Using the GUI
Wake-On-LAN with FlexAddress
When the FlexAddress feature is deployed for the first time on a given server module, it requires a power-down and power-up sequence for FlexAddress to take effect. FlexAddress on Ethernet devices is programmed by the server module BIOS. For the server module BIOS to program the address, it needs to be operational which requires the server module to be powered up.
When the power-down and power-up sequences complete, the chassis-assigned MAC IDs are available for Wake-On-LAN (WOL) function.
Troubleshooting FlexAddress
This section contains troubleshooting information for FlexAddress.
1 What happens if a feature card is removed?
Nothing happens. Feature cards can be removed and stored or may be left in place.
2 What happens if a feature card that was used in one chassis is removed and put into another chassis?
224 Using FlexAddress
The Web interface displays an error that states:
This feature card was activated with a different chassis. It must be removed before accessing the
FlexAddress feature.
Current Chassis Service Tag = XXXXXXXX
Feature Card Chassis Service Tag = YYYYYYYY
An entry is added to the CMC log that states: cmc <date timestamp> : feature
'FlexAddress@XXXXXXX' not activated; chassis ID=
'YYYYYYY'
3 What happens if the feature card is removed and a non-FlexAddress card is installed?
No activation or modifications to the card should occur. The card is ignored by CMC. In this situation, the $racadm featurecard -s returns a message of:
No feature card inserted
ERROR: can't open file
4 If the chassis service tag is reprogrammed, what happens if there is a feature card bound to that chassis?
• If the original feature card is present in the active CMC on that or any other chassis, the Web interface displays an error that states:
This feature card was activated with a different chassis. It must be removed before accessing the FlexAddress feature.
Current Chassis Service Tag = XXXXXXXX
Feature Card Chassis Service Tag = YYYYYYYY
Using FlexAddress 225
The original feature card is no longer eligible for deactivation on that or any other chassis, unless Dell Service re-programs the original chassis service tag back into a chassis, and CMC that has the original feature card is made active on that chassis.
• The FlexAddress feature remains activated on the originally bound chassis. The binding of that chassis feature is updated to reflect the new service tag.
5 Do I get an error if I have two feature cards installed in my redundant
CMC system?
The feature card in the active CMC is active and installed in the chassis.
The second card is ignored by CMC.
6 Does the SD card have a write protection lock on it?
Yes it does. Before installing the SD card into the CMC module, verify the write protection latch is in the unlock position. The FlexAddress feature cannot be activated if the SD card is write protected. In this situation, the $racadm feature -s command returns this message:
No features active on the chassis. ERROR: read only file system
7 What happens if there isn’t an SD card in the active CMC module?
The $racadm featurecard -s command returns this message:
No feature card inserted.
8 What happens to my FlexAddress feature if the server BIOS is updated from version 1.
xx to version 2.
xx ?
The server module needs to be powered down before it can be used with
FlexAddress. After the server BIOS update is complete, the server module does not get chassis-assigned addresses until the server has been power cycled.
226 Using FlexAddress
9 What happens if a chassis with a single CMC is downgraded with firmware prior to 1.10?
• The FlexAddress feature and configuration is removed from the chassis.
• The feature card used to activate the feature on this chassis is unchanged, and remains bound to the chassis. When this chassis’s
CMC firmware is subsequently upgraded to 1.10 or later, the
FlexAddress feature is reactivated by reinserting the original feature card (if necessary), resetting CMC (if feature card was inserted after firmware upgrade was completed), and reconfiguring the feature.
10 What happens if you are replacing a CMC unit with one that has firmware prior to 1.10 in a chassis with redundant CMCs?
In a chassis with redundant CMCs, if you are replacing a CMC unit with one that has firmware prior to 1.10, the following procedure must be used to ensure the current FlexAddress feature and configuration is NOT be removed. a b c
Ensure the active CMC firmware is always version 1.10 or later.
Remove the standby CMC and insert the new CMC in its place.
From the Active CMC, upgrade the standby CMC firmware to 1.10 or later.
NOTE: If you do not update the standby CMC firmware to 1.10 or later and a failover occurs, the FlexAddress feature is not configured and you need to reactivate and reconfigure the feature.
11 The SD card was not in the chassis when I executed the deactivation command on the FlexAddress. How do I recover my SD card now?
The issue is that the SD card cannot be used to install FlexAddress on another chassis if it was not in CMC when FlexAddress was deactivated.
To recover use of the card, insert the card back into a CMC in the chassis that it is bound to, reinstall FlexAddress, and then deactivate FlexAddress, again.
Using FlexAddress 227
12 I have the SD card properly installed and all the firmware/software updates installed. I see that FlexAddress is active, but I can’t see anything on the server deployment screen to deploy it? What is wrong?
This is a browser caching issue; shut down the browser and relaunch.
13 What happens to FlexAddress if I need to reset my chassis configuration using the RACADM command, racresetcfg ?
The FlexAddress feature is still be activated and ready to use. All fabrics and slots is selected as default.
NOTE: It is highly recommended that you power down your chassis before issuing the RACADM command racresetcfg .
Command Messages
The following table lists the RACADM commands and output for common
FlexAddress situations.
Table 6-2. FlexAddress Commands and Output
Situation Command Output
SD card in the active
CMC module is bound to another service tag.
$racadm featurecard -s The feature card inserted is valid and contains the following feature(s)
FlexAddress: The feature card is bound to another chassis, svctag =
J310TF1 SD card SN
=0188BFFE03A
228 Using FlexAddress
Table 6-2. FlexAddress Commands and Output (continued)
Situation Command Output
SD card in the active
CMC module that is bound to the same service tag.
$racadm featurecard -s The feature card inserted is valid and contains the following feature(s)
FlexAddress: The feature card is bound to this chassis
SD card in the active
CMC module that is not bound to any service tag.
$racadm featurecard -s The feature card inserted is valid and contains the following feature(s)
FlexAddress: The feature card is not bound to any chassis
FlexAddress feature not active on the chassis for any reason (No SD card inserted/ corrupt SD card/ after feature deactivated /SD card bound to a different chassis)
$racadm setflexaddr [-f
<fabricName>
<slotState>] OR
$racadm setflexaddr [-i
<slot#> <slotState>]
ERROR: Flexaddress feature is not active on the chassis
Guest user attempts to set FlexAddress on slots/fabrics
$racadm setflexaddr [-f
<fabricName>
<slotState>]
ERROR: Insufficient user privileges to perform operation
$racadm setflexaddr [-i
<slot#> <slotState>]
Using FlexAddress 229
Table 6-2. FlexAddress Commands and Output (continued)
Situation
Deactivating
FlexAddress feature with chassis powered
ON
Command
$racadm feature -d
-c flexaddress
Guest user tries to deactivate the feature on the chassis
$racadm feature -d
-c flexaddress
Changing the slot/fabric
FlexAddress settings while the server modules are powered
ON
$racadm setflexaddr -i
1 1
Output
ERROR: Unable to deactivate the feature because the chassis is powered
ON
ERROR: Insufficient user privileges to perform operation
ERROR: Unable to perform the set operation because it affects a powered ON server
230 Using FlexAddress
FlexAddress DELL SOFTWARE LICENSE
AGREEMENT
This is a legal agreement between you, the user, and Dell Products L.P. or
Dell Global B.V. ("Dell"). This agreement covers all software that is distributed with the Dell product, for which there is no separate license agreement between you and the manufacturer or owner of the software
(collectively the "Software"). This agreement is not for the sale of Software or any other intellectual property. All title and intellectual property rights in and to Software is owned by the manufacturer or owner of the Software. All rights not expressly granted under this agreement are reserved by the manufacturer or owner of the Software. By opening or breaking the seal on the Software packet(s), installing or downloading the Software, or using the Software that has been preloaded or is embedded in your product, you agree to be bound by the terms of this agreement. If you do not agree to these terms, promptly return all Software items (disks, written materials, and packaging) and delete any preloaded or embedded Software.
You may use one copy of the Software on only one computer at a time. If you have multiple licenses for the Software, you may use as many copies at any time as you have licenses. "Use" means loading the Software in temporary memory or permanent storage on the computer. Installation on a network server solely for distribution to other computers is not "use" if (but only if) you have a separate license for each computer to which the Software is distributed. You must ensure that the number of persons using the Software installed on a network server does not exceed the number of licenses that you have. If the number of users of Software installed on a network server exceeds the number of licenses, you must purchase additional licenses until the number of licenses equals the number of users before allowing additional users to use the Software. If you are a commercial customer of Dell or a Dell affiliate, you hereby grant Dell, or an agent selected by Dell, the right to perform an audit of your use of the Software during normal business hours, you agree to cooperate with Dell in such audit, and you agree to provide Dell with all records reasonably related to your use of the Software. The audit is limited to verification of your compliance with the terms of this agreement.
Using FlexAddress 231
The Software is protected by United States copyright laws and international treaties. You may make one copy of the Software solely for backup or archival purposes or transfer it to a single hard disk provided you keep the original solely for backup or archival purposes. You may not rent or lease the Software or copy the written materials accompanying the Software, but you may transfer the Software and all accompanying materials on a permanent basis as part of a sale or transfer of the Dell product if you retain no copies and the recipient agrees to the terms hereof. Any transfer must include the most recent update and all prior versions. You may not reverse engineer, decompile or disassemble the Software. If the package accompanying your computer contains compact discs, 3.5" and/or 5.25" disks, you may use only the disks appropriate for your computer. You may not use the disks on another computer or network, or loan, rent, lease, or transfer them to another user except as permitted by this agreement.
LIMITED WARRANTY
Dell warrants that the Software disks is free from defects in materials and workmanship under normal use for ninety (90) days from the date you receive them. This warranty is limited to you and is not transferable. Any implied warranties are limited to ninety (90) days from the date you receive the
Software. Some jurisdictions do not allow limits on the duration of an implied warranty, so this limitation may not apply to you. The entire liability of Dell and its suppliers, and your exclusive remedy, shall be (a) return of the price paid for the Software or (b) replacement of any disk not meeting this warranty that is sent with a return authorization number to Dell, at your cost and risk.
This limited warranty is void if any disk damage has resulted from accident, abuse, misapplication, or service or modification by someone other than Dell.
Any replacement disk is warranted for the remaining original warranty period or thirty (30) days, whichever is longer.
Dell does NOT warrant that the functions of the Software meets your requirements or that operation of the Software is uninterrupted or error free.
You assume responsibility for selecting the Software to achieve your intended results and for the use and results obtained from the Software.
DELL, ON BEHALF OF ITSELF AND ITS SUPPLIERS, DISCLAIMS ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, FOR THE SOFTWARE
232 Using FlexAddress
AND ALL ACCOMPANYING WRITTEN MATERIALS. This limited warranty gives you specific legal rights; you may have others, which vary from jurisdiction to jurisdiction.
IN NO EVENT SHALL DELL OR ITS SUPPLIERS BE LIABLE FOR ANY
DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION,
DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS
INTERRUPTION, LOSS OF BUSINESS INFORMATION, OR OTHER
PECUNIARY LOSS) ARISING OUT OF USE OR INABILITY TO USE
THE SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. Because some jurisdictions do not allow an exclusion or limitation of liability for consequential or incidental damages, the above limitation may not apply to you.
OPEN SOURCE SOFTWARE
A portion of this CD may contain open source software, which you can use under the terms and conditions of the specific license under which the open source software is distributed.
THIS OPEN SOURCE SOFTWARE IS DISTRIBUTED IN THE HOPE
THAT IT WILL BE USEFUL, BUT IS PROVIDED "AS IS" WITHOUT
ANY EXPRESSED OR IMPLIED WARRANTY; INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL DELL,
THE COPYRIGHT HOLDERS, OR THE CONTRIBUTORS BE LIABLE
FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY,
OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED
TO, PROCUREMENT OF SUBSTUTUTE GOODS OR SERVICES; LOSS
OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILTIY,
WHETHER IN CONTRACT, STRICT LIABITLY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
POSSIBILTIY OF SUCH DAMAGE.
.U.S. GOVERNMENT RESTRICTED RIGHTS
The software and documentation are "commercial items" as that term is defined at 48 C.F.R. 2.101, consisting of "commercial computer software" and
"commercial computer software documentation" as such terms are used in 48
C.F.R. 12.212. Consistent with 48 C.F.R. 12.212 and 48 C.F.R. 227.7202-1 through 227.7202-4, all U.S. Government end users acquire the software and
Using FlexAddress 233
documentation with only those rights set forth herein.
Contractor/manufacturer is Dell Products, L.P., One Dell Way, Round Rock,
Texas 78682.
GENERAL
This license is effective until terminated. It terminates upon the conditions set forth above or if you fail to comply with any of its terms.
Upon termination, you agree that the Software and accompanying materials, and all copies thereof, is destroyed. This agreement is governed by the laws of the State of Texas. Each provision of this agreement is severable. If a provision is found to be unenforceable, this finding does not affect the enforceability of the remaining provisions, terms, or conditions of this agreement. This agreement is binding on successors and assigns. Dell agrees and you agree to waive, to the maximum extent permitted by law, any right to a jury trial with respect to the Software or this agreement. Because this waiver may not be effective in some jurisdictions, this waiver may not apply to you.
You acknowledge that you have read this agreement, that you understand it, that you agree to be bound by its terms, and that this is the complete and exclusive statement of the agreement between you and Dell regarding the
Software.
234 Using FlexAddress
7
Using FlexAddress Plus
The FlexAddress Plus is a new feature added to the feature card version 2.0. It is an upgrade from FlexAddress feature card version 1.0. FlexAddress Plus contains more MAC addresses than the FlexAddress feature. Both features allow the chassis to assign WWN/MAC (World Wide Name/Media Access
Control) addresses to Fibre Channel and Ethernet devices. Chassis assigned
WWN/MAC addresses are globally unique and specific to a server slot.
Activating FlexAddress Plus
FlexAddress Plus is delivered on the FlexAddress Plus Secure Digital (SD) card along with the FlexAddress feature.
NOTE: The SD card labeled FlexAddress only contains FlexAddress and the card labeled FlexAddress Plus contains FlexAddress and FlexAddress Plus. The card must be inserted into CMC to activate the feature.
Some servers, such as the PowerEdge M710HD, may require more MAC addresses than FA can provide to CMC, depending on how they are configured. For these servers, upgrading to FA+ enables full optimization of the WWN/MACs configuration. Please contact Dell to obtain support for the
FlexAddress Plus feature.
To activate the FlexAddress Plus feature, the following software updates are required: server BIOS, server iDRAC, and CMC firmware. If these updates are not applied, only FlexAddress feature is available.
Table 7-1. Updates Required for Flexaddress Plus
Component
Server Module BIOS iDRAC
CMC
Minimum required version
PowerEdge M710hd
Version 3.0 or later
Version 3.0 or later
Using FlexAddress Plus 235
FlexAddress vs FlexAddress Plus
FlexAddress has 208 addresses divided into 16 server slots, thus each slot is allocated with 13 MACs. FlexAddress Plus has 2928 addresses divided into 16 server slots, thus each slot is allocated with 183 MACs. The table below shows the provision of the MAC addresses in both the features.
Fabric A Fabric B Fabric C iDRAC
Management
FlexAddress 4
FlexAddress
Plus
60
4
60
4
60
1
3
Figure 7-1. FlexAdress (FA) vs FlexPlusAddress (FA+) Features iDRAC
Fabric A
Fabric B
Fabric C
FA
Total MACs
13
183 iDRAC
Fabric A
Fabric B
Fabric C
Slot 16
FA+ iDRAC
Fabric A
Fabric B
Fabric C
Slot 16
236 Using FlexAddress Plus
Scheme 1 and Scheme 2 MAC Address Allocation
For backward compatibility with FA, the addresses in FA+ are divided into two groups: the first group has 208 addresses and the second group has 2928 addresses. In the first group, 13 MACs are allocated to each of the 16 slots in the same way FA does. In the second group, 183 MACs are allocated for each slot.
The allocation of the 13 MAC addresses of the first group for each server is divided as: one for iDRAC and four for each fabric, A, B, and C. Within each fabric, A, B, and C, two addresses are allocated for port 1 and 2 addresses are allocated for port 2. The result is:
• 1 MAC for iDRAC management
• 4 MACs for fabric A (two MACs for port 1, two MACs for port 2)
• 4 MACs for fabric B (two MACs for port 1, two MACs for port 2)
• 4 MACs for fabric C (two MACs for port 1, two MACs for port 2)
For references, this MAC address allocation is called scheme 1.
The allocation of the 183 MAC address for the second group of each server is also divided as: three for iDRAC, 60 for each fabric, A, B and C. Within each fabric, 30 addresses are allocated for port 1 and 30 addresses are allocated for port 2. The result is:
• 3 MACs for iDRAC management
• 60 MACs for fabric A (30 MACs for port 1, 30 MACs for port 2)
• 60 MACs for fabric B (30 MACs for port 1, 30 MACs for port 2)
• 60 MACs for fabric C (30 MACs for port 1, 30 MACs for port 2)
For references, this MAC address allocation is called scheme 2.
The common way of MAC addresses allocation is to allocate MAC addresses per fabric from scheme 1 initially. If a fabric requires more addresses than scheme 1 can provide, additional two MACs per fabric is allocated from scheme 2.
When a chassis is activated only with FA and it has a server with a network configuration that requires more addresses than scheme 1 can provide, the additional addresses are not available. The status is displayed as Not
Installed .
Using FlexAddress Plus 237
If a chassis currently has FA activated, FA does not need to be deactivated in order to add FA+.
In this case, the MAC address allocations are applied as follows:
• The MAC addresses of scheme 1 are allocated from FA of the feature card
1.0. There is no change in the previous WWN/MAC configuration.
• The additional MAC addresses of scheme 2 are allocated from the scheme
2 addresses of FA+.
MAC Address Allocation Example
Assume that, the starting address of MACs in FA is 00:FA:AE:58:59:2B, the starting address of the MACs in scheme 2 of FA+ is 00:FB:AE:58:59:FB. The server is in slot 1, the network configuration for the server is:
• 1 MAC for iDRAC
• 8 MACs for fabric A
• 4 MACs for fabric B
• 4 MACs for fabric C
Since fabric A needs four more MAC addresses than scheme 1 can provide, the first 4 MACs are allocated from FA based on scheme 1 with two MACs for port 1, and two MACs for port 2. The additional four MACs are allocated from FA+ based on scheme 2, with two MACs for port 1 and two MACs for port 2. The MAC addresses allocation for iDRAC for fabric B and C are from
FA based on scheme 1.
The starting address of fabric A port 1 from FA+ is 00:23:AE:58:59:FE, because the first 3 MACs are reserved for iDRAC. Thus the chassis-assigned
MAC addresses for the server are: iDRAC
Fabric A port 1:
00:FA:AE:58:59:2B (from FA)
00:FA:AE:58:59:2C(from FA)
00:FA:AE:58:59:2D (from FA)
00:FB:AE:58:59:FE (from FA+)
00:FB:AE:58:59:FF (from FA+)
238 Using FlexAddress Plus
Fabric A port 2:
Fabric B port 1:
Fabric B port 2:
Fabric C port 1:
Fabric C port 2:
00:FA:AE:58:59:2E (from FA)
00:FA:AE:58:59:2F (from FA)
00:FB:AE:58:5A:00 (from FA+)
00:FB:AE:58:5A:01 (from FA+)
00:FA:AE:58:59:30 (from FA)
00:FA:AE:58:59:31 (from FA)
00:FA:AE:58:59:32 (from FA)
00:FA:AE:58:59:33 (from FA)
00:FA:AE:58:59:34 (from FA)
00:FA:AE:58:59:35 (from FA)
00:FA:AE:58:59:36 (from FA)
00:FA:AE:58:59:37 (from FA)
When a chassis with no previous FA—either it has never been activated or it was activated and then deactivated—and it has a server with the network configuration that requires more addresses than scheme 1 can provide, the scheme 1 allocation acquires addresses from scheme 1 of FA and scheme 2 allocation acquires addresses from scheme 2 of FA+.
Using the same example, the chassis-assigned MAC addresses of the same server in this scenarios are as follows: iDRAC
Fabric A port 1:
Fabric A port 2:
Fabric B port 1:
00:FB:AE:58:59:2B (FA)
00:FB:AE:58:59:2C (FA)
00:FB:AE:58:59:2D (FA)
00:FB:AE:58:59:FE (FA+)
00:FB:AE:58:59:FF (FA+)
00:FB:AE:58:59:2E (FA)
00:FB:AE:58:59:2F (FA)
00:FB:AE:58:5A:00 (FA+)
00:FB:AE:58:5A:01 (FA+)
00:FB:AE:58:59:30 (FA)
00:FB:AE:58:59:31 (FA)
Using FlexAddress Plus 239
Fabric B port 2:
Fabric C port 1:
Fabric C port 2:
00:FB:AE:58:59:32 (FA)
00:FB:AE:58:59:33 (FA)
00:FB:AE:58:59:34 (FA)
00:FB:AE:58:59:35 (FA)
00:FB:AE:58:59:36 (FA)
00:FB:AE:58:59:37 (FA)
240 Using FlexAddress Plus
Using the CMC Directory Service
8
A directory service maintains a common database of all information needed for controlling network users, computers, printers, and so on. If your company uses the Microsoft Active Directory service software or the LDAP Directory
Service software, you can configure CMC to use directory based user authentication.
Using CMC with Microsoft Active Directory
NOTE: Using Active Directory to recognize CMC users is supported on the
Microsoft Windows 2000 and Windows Server 2003 operating systems. Active
Directory over IPv6 is supported only on Windows 2008.
Active Directory Schema Extensions
You can use Active Directory to define user access on CMC through two methods:
• The standard schema solution that uses only the standard Active Directory group objects.
• The extended schema solution that uses Active Directory objects defined by Dell.
Standard Schema Versus Extended Schema
When using Active Directory to configure access to CMC, you must choose either the extended schema or the standard schema solution.
With the standard schema solution:
• No schema extension is required, because standard schema uses only standard Active Directory objects.
• Configuration of the Active Directory is simple.
With the extended schema solution:
• All of the access control objects are maintained in Active Directory.
• Configuring user access on different CMCs with different privilege levels allows maximum flexibility.
241 Using the CMC Directory Service
Standard Schema Active Directory Overview
Using standard schema for Active Directory integration requires configuration on both Active Directory and CMC.
On the Active Directory side, a standard group object is used as a role group.
A user who has CMC access is a member of the role group.
In order to give this user access to a specific CMC card, the role group name and its domain name need to be configured on the specific CMC card. Unlike the extended schema solution, the role and the privilege level is defined on each CMC card, not in the Active Directory. Up to five role groups can be
configured and defined in each CMC. Table 5-41 shows the privileges level of
the role groups and Table 8-1 shows the default role group settings.
Figure 8-1. Configuration of CMC with Active Directory and Standard Schema
Configuration on Active
Directory Side
Configuration on
CMC Side
Role
Group
Role
Group Name and Domain
Name
Role
Definition
User
242 Using the CMC Directory Service
2
3
4
5
Table 8-1. Default Role Group Privileges
Role Group Default
1
Privilege
Level
None
Permissions Granted
None
None
None
None
Bit Mask
• CMC Login User
• Chassis Configuration
Administrator
• User Configuration Administrator
• Clear Logs Administrator
• Chassis Control Administrator
(Power Commands)
• Super User
• Server Administrator
• Test Alert User
• Debug Command User
• Fabric A Administrator
• Fabric B Administrator
• Fabric C Administrator
• CMC Login User
• Clear Logs Administrator
• Chassis Control Administrator
(Power Commands)
• Server Administrator
• Test Alert User
• Fabric A Administrator
• Fabric B Administrator
• Fabric C Administrator
CMC Login User
No assigned permissions
No assigned permissions
0x00000fff
0x000000f9
0x00000001
0x00000000
0x00000000
Using the CMC Directory Service 243
NOTE: The bit mask values are used only when setting Standard Schema with the RACADM.
NOTE:
For more information about user privileges, see "User Types" on page 154.
There are two ways to enable Standard Schema Active Directory:
• With the CMC Web interface. See "Configuring CMC With Standard
Schema Active Directory and Web Interface" on page 244.
• With the RACADM CLI tool. See "Configuring CMC With Standard
Schema Active Directory and RACADM" on page 247.
Configuring Standard Schema Active Directory to Access CMC
Perform the following steps to configure the Active Directory before an Active
Directory user can access CMC:
1 On an Active Directory server (domain controller), open the Active
Directory Users and Computers Snap-in.
2 Create a group or select an existing group. The name of the group and the name of this domain must be configured on CMC using the Web interface or RACADM.
For more information, see "Configuring CMC With Standard Schema
Active Directory and Web Interface" on page 244 or "Configuring CMC
With Standard Schema Active Directory and RACADM" on page 247.
3 Add the Active Directory user as a member of the Active Directory group to access CMC.
Configuring CMC With Standard Schema Active Directory and Web Interface
1 Log in to the CMC Web interface.
2 Select Chassis in the system tree.
3 Click User Authentication ï‚® Directory Services .The Directory Services page is displayed.
4 Select the radio button next to Microsoft Active Directory (Standard
Schema). The Active Directory Configuration and Management page appears.
244 Using the CMC Directory Service
5 In the Common Settings section: a Select the Enable Active Directory check box.
b Type the Root Domain Name .
NOTE: The Root domain name must be a valid domain name using the x.y
naming convention, where between characters, and mil, net, or org.
y x is a 1–256 character ASCII string with no spaces
is a valid domain type such as com, edu, gov, int, c Type the Timeout in seconds. Timeout range is 15–300 seconds.
Default timeout period is 90 seconds.
6 If you want the directed call to search the domain controller and global catalog, select the Search AD Server to search (Optional) check box, and do the following: a b
In the Domain Controller text field, type the server where your Active
Directory service is installed.
In the Global Catalog text field, type the location of the global catalog on the Active Directory domain controller. The global catalog provides a resource for searching an Active Directory forest.
7 Click Apply to save your settings.
NOTE: You must apply your settings before continuing to the next step. If you do not apply the settings, you will lose the settings you entered after you navigate to the next page.
8 In the Standard Schema Settings section, click a Role Group .
The Configure Role Group page appears.
9 Type the Group Name . The group name identifies the role group in the
Active Directory associated with the CMC card.
10 Type the Group Domain . The Group Domain is the fully qualified root domain name for the forest.
11 In the Role Group Privileges page, select privileges for the group.
If you modify any of the privileges, the existing Role Group Privilege
(Administrator, Power User, or Guest User) changes to either the Custom
group or the appropriate Role Group Privilege. See Table 5-41.
12 Click Apply to save the Role Group settings.
13 Click Go Back To Configuration page .
Using the CMC Directory Service 245
14 Upload your domain forest Root certificate authority-signed certificate into CMC. In the Certificate Management section, type the file path of the certificate or browse to the certificate file. Click the Upload button to transfer the file to CMC.
NOTE: The File Path value displays the relative file path of the certificate you are uploading. You must type the absolute file path, which includes the full path and the complete file name and file extension.
The SSL certificates for the domain controllers must be signed by the root certificate authority-signed certificate. The root certificate authority-signed certificate must be available on the management station accessing CMC.
15 Click Apply . The CMC Web server automatically restarts after you click
Apply .
16 Log out and then log in to CMC to complete the CMC Active Directory feature configuration.
17 Select Chassis in the system tree.
18 Click the Network tab.
19 Click the Network subtab. The Network Configuration page appears.
20 If Use DHCP (for CMC Network Interface IP Address) is selected under
Network Settings , select Use DHCP to obtain DNS server address .
To manually enter a DNS server IP address, clear Use DHCP to obtain DNS server addresses and type your primary and alternate
DNS server IP addresses.
21 Click Apply Changes .
The CMC Standard Schema Active Directory feature configuration is complete.
246 Using the CMC Directory Service
Configuring CMC With Standard Schema Active Directory and RACADM
To configure the CMC Active Directory Feature with Standard Schema using the RACADM CLI, use the following commands:
1 Open a serial/Telnet/SSH text console to the CMC, and type: racadm config -g cfgActiveDirectory -o cfgADEnable 1 racadm config -g cfgActiveDirectory -o cfgADType 2 racadm config -g cfgActiveDirectory -o cfgADRootDomain < fully qualified root domain name > racadm config -g cfgStandardSchema -i <index> -o cfgSSADRoleGroupName < common name of the role group > racadm config -g cfgStandardSchema -i <index> -o cfgSSADRoleGroupDomain < fully qualified domain name > racadm config -g cfgStandardSchema -i <index> -o cfgSSADRoleGroupPrivilege <Bit mask number for specific user permissions> racadm sslcertupload -t 0x2 -f < ADS root CA certificate > racadm sslcertdownload -t 0x1 -f < RAC SSL certificate >
NOTE: For bit mask number values, see Table 3-1 in the database property chapter of the Dell Chassis Management Controller Administrator
Reference Guide .
Using the CMC Directory Service 247
2 Specify a DNS server using one of the following options:
• If DHCP is enabled on CMC and you want to use the DNS address obtained automatically by the DHCP server, type the following command: racadm config -g cfgLanNetworking -o cfgDNSServersFromDHCP 1
• If DHCP is disabled on CMC or you want manually to input your
DNS IP address, type the following commands: racadm config -g cfgLanNetworking -o cfgDNSServersFromDHCP 0 racadm config -g cfgLanNetworking -o cfgDNSServer1 < primary DNS IP address > racadm config -g cfgLanNetworking -o cfgDNSServer2 <secondary DNS IP address >
Extended Schema Overview
There are two ways to enable Extended Schema in Active Directory:
• Using the CMC Web interface. For instructions, see "Configuring CMC
With Extended Schema Active Directory and the Web Interface" on page 264.
• Using the RACADM CLI tool. For instructions, see "Configuring CMC
With Extended Schema Active Directory and RACADM" on page 267.
Active Directory Schema Extensions
The Active Directory data is a distributed database of Attributes and Classes.
The Active Directory schema includes the rules that determine the type of data that can be added or included in the database.
One example of a Class that is stored in the database is the user class.
User class attributes can include the user’s first name, last name, phone number, and so on.
248 Using the CMC Directory Service
You can extend the Active Directory database by adding your own unique
Attributes and Classes to address your company’s environment-specific needs. Dell has extended the schema to include the necessary changes to support remote management Authentication and Authorization.
Each Attribute or Class that is added to an existing Active Directory Schema must be defined with a unique ID. To maintain unique IDs across the industry, Microsoft maintains a database of Active Directory Object
Identifiers (OIDs). To extend the schema in Microsoft's Active Directory,
Dell established unique OIDs, unique name extensions, and uniquely linked attribute IDs for Dell-specific Attributes and Classes:
Dell extension: dell
Dell base OID: 1.2.840.113556.1.8000.1280
RAC LinkID range: 12070–2079
Overview of the RAC Schema Extensions
Dell provides a group of properties that you can configure. The Dell extended schema include Association, Device, and Privilege properties.
The Association property links together users or groups with a specific set of privileges to one or more RAC devices. This model provides an Administrator maximum flexibility over the different combinations of users, RAC privileges, and RAC devices on the network without adding too much complexity.
Active Directory Object Overview
When there are two CMCs on the network that you want to integrate with
Active Directory for Authentication and Authorization, you must create at least one Association Object and one RAC Device Object for each CMC.
You can create multiple Association Objects, and each Association Object can be linked to as many users, groups of users, or RAC Device Objects as required. The users and RAC Device Objects can be members of any domain in the enterprise.
However, each Association Object can be linked (or, may link users, groups of users, or RAC Device Objects) to only one Privilege Object. This example allows an Administrator to control each user’s privileges on specific CMCs.
Using the CMC Directory Service 249
The RAC Device object is the link to the RAC firmware for querying Active
Directory for authentication and authorization. When a RAC is added to the network, the Administrator must configure the RAC and its device object with its Active Directory name so users can perform authentication and authorization with Active Directory. Additionally, the Administrator must add the RAC to at least one Association Object in order for users to authenticate.
Figure 8-2 illustrates that the Association Object provides the connection
that is needed for all of the Authentication and Authorization.
NOTE: The RAC privilege object applies to DRAC 4, DRAC 5, and CMC.
You can create as many or as few Association Objects as required. However, you must create at least one Association Object, and you must have one
RAC Device Object for each RAC (CMC) on the network that you want to integrate with Active Directory.
Figure 8-2. Typical Setup for Active Directory Objects
Association Object
User(s) Group(s) Privilege Object RAC Device Object(s)
RAC Privilege Object
250 Using the CMC Directory Service
The Association Object allows for as many or as few users and/or groups as well as RAC Device Objects. However, the Association Object only includes one Privilege Object per Association Object. The Association Object connects the "Users" who have "Privileges" on the RACs (CMCs).
Additionally, you can configure Active Directory objects in a single domain or in multiple domains. For example, you have two CMCs (RAC1 and RAC2) and three existing Active Directory users (user1, user2, and user3). You want to give user1 and user2 an administrator privilege to both CMCs and give
user3 a login privilege to the RAC2 card. Figure 8-3 illustrates how you set up
the Active Directory objects in this scenario.
When adding Universal Groups from separate domains, create an Association
Object with Universal Scope. The Default Association objects created by the
Dell Schema Extender Utility are Domain Local Groups and does not work with Universal Groups from other domains.
Figure 8-3. Setting Up Active Directory Objects in a Single Domain
AO1 AO2
Group1 Priv1 Priv2
User1 User2 User3 RAC1 RAC2
Using the CMC Directory Service 251
To configure the objects for the single domain scenario:
1 Create two Association Objects.
2 Create two RAC Device Objects, RAC1 and RAC2, to represent the two
CMCs.
3 Create two Privilege Objects, Priv1 and Priv2, in which Priv1 has all privileges (administrator) and Priv2 has login privilege.
4 Group user1 and user2 into Group1.
5 Add Group1 as Members in Association Object 1 (A01), Priv1 as Privilege
Objects in A01, and RAC1, RAC2 as RAC Devices in A01.
6 Add User3 as Members in Association Object 2 (A02), Priv2 as Privilege
Objects in A02, and RAC2 as RAC Devices in A02.
For detailed instruction, see "Adding CMC Users and Privileges to Active
Figure 8-4 provides an example of Active Directory objects in multiple
domains. In this scenario, you have two CMCs (RAC1 and RAC2) and three existing Active Directory users (user1, user2, and user3). User1 is in
Domain1, and user2 and user 3 are in Domain2. In this scenario, configure user1 and user 2 with administrator privileges to both CMCs and configure user3 with login privileges to the RAC2 card.
252 Using the CMC Directory Service
Figure 8-4. Setting Up Active Directory Objects in Multiple Domains
Domain1 Domain2
AO1 AO2
Group1 Priv1 Priv2
User1 User2 User3 RAC1 RAC2
To configure the objects for the multiple domain scenario:
1 Ensure that the domain forest function is in Native or Windows 2003 mode.
2 Create two Association Objects, A01 (of Universal scope) and A02, in any domain.
Figure 8-4 shows the objects in Domain2.
3 Create two RAC Device Objects, RAC1 and RAC2, to represent the two CMCs.
4 Create two Privilege Objects, Priv1 and Priv2, in which Priv1 has all privileges (administrator) and Priv2 has login privilege.
5 Group user1 and user2 into Group1. The group scope of Group1 must be Universal.
Using the CMC Directory Service 253
6 Add Group1 as Members in Association Object 1 (A01), Priv1 as Privilege
Objects in A01, and RAC1, RAC2 as RAC Devices in A01.
7 Add User3 as Members in Association Object 2 (A02), Priv2 as Privilege
Objects in A02, and RAC2 as RAC Devices in A02.
Configuring Extended Schema Active Directory to Access Your CMC
Before using Active Directory to access your CMC, configure the Active
Directory software and CMC:
1
Extend the Active Directory schema (see "Extending the Active Directory
2
3
Add CMC users and their privileges to Active Directory (see "Adding
CMC Users and Privileges to Active Directory" on page 262).
4 Enable SSL on each of your domain controllers.
5 Configure the CMC Active Directory properties using either the CMC
Web interface or the RACADM (see "Configuring CMC With Extended
Schema Active Directory and the Web Interface" on page 264 or
"Configuring CMC With Extended Schema Active Directory and
Extending the Active Directory Schema
Extending your Active Directory schema adds a Dell organizational unit, schema classes and attributes, and example privileges and association objects to the Active Directory schema. Before you extend the schema, ensure that you have Schema Admin privilege on the Schema Master Flexible Single
Master Operation (FSMO) Role Owner of the domain forest.
254 Using the CMC Directory Service
You can extend your schema using one of the following methods:
• Dell Schema Extender utility
• LDIF script file
If you use the LDIF script file, the Dell organizational unit is not be added to the schema.
The LDIF files and Dell Schema Extender are located on your Dell Systems
Management Tools and Documentation DVD in the following respective directories:
• <DVDdrive>:\SYSMGMT\ManagementStation\support\
OMActiveDirectory_Tools\<installation type>\LDIF Files
• <DVDdrive>:\SYSMGMT\ManagementStation\support\
OMActiveDirectory_ Tools\<installation type>\Schema Extender
To use the LDIF files, see the instructions in the readme included in the
LDIF_Files directory. For instructions on using the Dell Schema Extender to
extend the Active Directory Schema, see "Using the Dell Schema Extender" on page 255.
You can copy and run the Schema Extender or LDIF files from any location.
Using the Dell Schema Extender
CAUTION: The Dell Schema Extender uses the SchemaExtenderOem.ini file. To ensure that the Dell Schema Extender utility functions properly, do not modify the name of this file.
1 In the Welcome screen, click Next.
2 Read and understand the warning and click Next .
3 Select Use Current Log In Credentials or enter a user name and password with schema administrator rights.
Using the CMC Directory Service 255
4 Click Next to run the Dell Schema Extender.
5 Click Finish .
The schema is extended. To verify the schema extension, use the
Microsoft Management Console (MMC) and the Active Directory
Schema Snap-In to verify that the following exist:
• Classes — see Table 8-2 through Table 8-7
See your Microsoft documentation for more information on how to enable and use the Active Directory Schema Snap-In the MMC.
Table 8-2. Class Definitions for Classes Added to the Active Directory Schema
Class Name Assigned Object Identification Number (OID) dellRacDevice 1.2.840.113556.1.8000.1280.1.1.1.1
dellAssociationObject 1.2.840.113556.1.8000.1280.1.1.1.2
dellRACPrivileges dellPrivileges dellProduct
1.2.840.113556.1.8000.1280.1.1.1.3
1.2.840.113556.1.8000.1280.1.1.1.4
1.2.840.113556.1.8000.1280.1.1.1.5
Table 8-3. dellRacDevice Class
OID
Description
1.2.840.113556.1.8000.1280.1.1.1.1
Represents the Dell RAC device. The RAC device must be configured as dellRacDevice in Active Directory. This configuration enables CMC to send Lightweight Directory Access Protocol
(LDAP) queries to Active Directory.
Class Type Structural Class
SuperClasses dellProduct
Attributes dellSchemaVersion dellRacType
256 Using the CMC Directory Service
Table 8-4. dellAssociationObject Class
OID
Description
1.2.840.113556.1.8000.1280.1.1.1.2
Represents the Dell Association Object. The Association Object provides the connection between the users and the devices.
Class Type Structural Class
SuperClasses Group
Attributes dellProductMembers dellPrivilegeMember
Table 8-5. dellRAC4Privileges Class
OID
Description
1.2.840.113556.1.8000.1280.1.1.1.3
Defines Authorization Rights (privileges) for the CMC device.
Class Type Auxiliary Class
SuperClasses None
Attributes dellIsLoginUser dellIsCardConfigAdmin dellIsUserConfigAdmin dellIsLogClearAdmin dellIsServerResetUser dellIsTestAlertUser dellIsDebugCommandAdmin dellPermissionMask1 dellPermissionMask2
Using the CMC Directory Service 257
258
Table 8-6. dellPrivileges Class
OID
Description
1.2.840.113556.1.8000.1280.1.1.1.4
Container Class for the Dell Privileges (Authorization Rights).
Class Type Structural Class
SuperClasses User
Attributes dellRAC4Privileges
Table 8-7. dellProduct Class
OID
Description
1.2.840.113556.1.8000.1280.1.1.1.5
The main class from which all Dell products are derived.
Class Type Structural Class
SuperClasses Computer
Attributes dellAssociationMembers
Table 8-8. List of Attributes Added to the Active Directory Schema
Assigned OID/Syntax Object Identifier Single Valued
Attribute: dellPrivilegeMember
Description: List of dellPrivilege objects that belong to this attribute.
OID: 1.2.840.113556.1.8000.1280.1.1.2.1
Distinguished Name: (LDAPTYPE_DN
1.3.6.1.4.1.1466.115.121.1.12)
Attribute: dellProductMembers
Description: List of dellRacDevices objects that belong to this role.
This attribute is the forward link to the dellAssociationMembers backward link.
Link ID: 12070
OID: 1.2.840.113556.1.8000.1280.1.1.2.2
Distinguished Name: (LDAPTYPE_DN
1.3.6.1.4.1.1466.115.121.1.12)
FALSE
FALSE
Using the CMC Directory Service
Table 8-8. List of Attributes Added to the Active Directory Schema (continued)
Assigned OID/Syntax Object Identifier Single Valued
Attribute: dellIsCardConfigAdmin
Description: TRUE if the user has Card Configuration rights on the device.
OID: 1.2.840.113556.1.8000.1280.1.1.2.4
Boolean (LDAPTYPE_BOOLEAN 1.3.6.1.4.1.1466.115.121.1.7)
TRUE
Attribute: dellIsLoginUser
Description: TRUE if the user has Login rights on the device.
OID: 1.2.840.113556.1.8000.1280.1.1.2.3
Boolean (LDAPTYPE_BOOLEAN 1.3.6.1.4.1.1466.115.121.1.7)
TRUE
Attribute: dellIsCardConfigAdmin
Description: TRUE if the user has Card Configuration rights on the device.
OID: 1.2.840.113556.1.8000.1280.1.1.2.4
Boolean (LDAPTYPE_BOOLEAN 1.3.6.1.4.1.1466.115.121.1.7)
TRUE
Attribute: dellIsUserConfigAdmin
Description: TRUE if the user has User Configuration
Administrator rights on the device.
OID: 1.2.840.113556.1.8000.1280.1.1.2.5
Boolean (LDAPTYPE_BOOLEAN 1.3.6.1.4.1.1466.115.121.1.7)
TRUE
Attribute: delIsLogClearAdmin
Description: TRUE if the user has Clear Logs Administrator rights on the device.
OID: 1.2.840.113556.1.8000.1280.1.1.2.6
Boolean (LDAPTYPE_BOOLEAN 1.3.6.1.4.1.1466.115.121.1.7)
Attribute: dellIsServerResetUser
Description: TRUE if the user has Server Reset rights on the device.
OID: 1.2.840.113556.1.8000.1280.1.1.2.7
Boolean (LDAPTYPE_BOOLEAN 1.3.6.1.4.1.1466.115.121.1.7)
TRUE
TRUE
Using the CMC Directory Service 259
260
Table 8-8. List of Attributes Added to the Active Directory Schema (continued)
Assigned OID/Syntax Object Identifier Single Valued
Attribute: dellIsTestAlertUser
Description: TRUE if the user has Test Alert User rights on the device.
OID: 1.2.840.113556.1.8000.1280.1.1.2.10
Boolean (LDAPTYPE_BOOLEAN 1.3.6.1.4.1.1466.115.121.1.7)
TRUE
Attribute: dellIsDebugCommandAdmin
Description: TRUE if the user has Debug Command Admin rights on the device.
OID: 1.2.840.113556.1.8000.1280.1.1.2.11
Boolean (LDAPTYPE_BOOLEAN 1.3.6.1.4.1.1466.115.121.1.7)
TRUE
Attribute: dellSchemaVersion
Description: The Current Schema Version is used to update the schema.
TRUE OID: 1.2.840.113556.1.8000.1280.1.1.2.12
Case Ignore String(LDAPTYPE_CASEIGNORESTRING
1.2.840.113556.1.4.905)
Attribute: dellRacType
Description: This attribute is the Current Rac Type for the dellRacDevice object and the backward link to the dellAssociationObjectMembers forward link.
TRUE OID: 1.2.840.113556.1.8000.1280.1.1.2.13
Case Ignore String(LDAPTYPE_CASEIGNORESTRING
1.2.840.113556.1.4.905)
Attribute: dellAssociationMembers
Description: List of dellAssociationObjectMembers that belong to this Product. This attribute is the backward link to the dellProductMembers Linked attribute.
Link ID: 12071
OID: 1.2.840.113556.1.8000.1280.1.1.2.14
Distinguished Name (LDAPTYPE_DN
1.3.6.1.4.1.1466.115.121.1.12)
Attribute: dellPermissionsMask1
FALSE
Using the CMC Directory Service
Table 8-8. List of Attributes Added to the Active Directory Schema (continued)
Assigned OID/Syntax Object Identifier Single Valued
OID: 1.2.840.113556.1.8000.1280.1.6.2.1 Integer (LDAPTYPE_INTEGER)
Attribute: dellPermissionsMask2
OID: 1.2.840.113556.1.8000.1280.1.6.2.2 Integer (LDAPTYPE_INTEGER)
Installing the Dell Extension to the Active Directory Users and
Computers Snap-In
When you extend the schema in Active Directory, you must also extend the
Active Directory Users and Computers Snap-In so the administrator can manage RAC (CMC) devices, Users and User Groups, RAC Associations, and RAC Privileges.
When you install your systems management software using the Dell Systems
Management Tools and Documentation DVD, you can extend the Snap-In by selecting the Dell Extension to the Active Directory User’s and Computers
Snap-In option during the installation procedure. See the Dell OpenManage
Server Administrator Installation Guide and and Dell OpenManage
Management Station Software Installation Guide for additional instructions about installing systems management software.
For more information about the Active Directory User’s and Computers
Snap-In, see your Microsoft documentation.
Installing the Administrator Pack
You must install the Administrator Pack on each system that is managing the
Active Directory CMC Objects. If you do not install the Administrator Pack, you cannot view the Dell RAC Object in the container.
Opening the Active Directory Users and Computers Snap-In
To open the Active Directory Users and Computers Snap-In:
1 If you are logged into the domain controller, click Start Admin Tools ï‚®
Active Directory Users and Computers .
If you are not logged into the domain controller, you must have the appropriate Microsoft Administrator Pack installed on your local system.
To install this Administrator Pack, click Start ï‚® Run , type MMC , and press
<Enter>.
Using the CMC Directory Service 261
262
The Microsoft Management Console (MMC) appears.
2 In the Console 1 window, click File (or Console on systems running
Windows 2000).
3 Click Add/Remove Snap-in .
4 Select the Active Directory Users and Computers Snap-In and click Add .
5 Click Close and click OK .
Adding CMC Users and Privileges to Active Directory
Using the Dell-extended Active Directory Users and Computers Snap-In, you can add CMC users and privileges by creating RAC, Association, and Privilege objects. To add each object type:
1 Create a RAC device Object.
2 Create a Privilege Object.
3 Create an Association Object.
4 Add objects to an Association Object.
Creating a RAC Device Object
1 In the MMC Console Root window, right-click a container.
2 Select New ï‚® Dell RAC Object .
The New Object window appears.
3 Type a name for the new object. The name must be identical to CMC
Name that you type in step 8a of "Configuring CMC With Extended
Schema Active Directory and the Web Interface" on page 264.
4 Select RAC Device Object .
5 Click OK .
Creating a Privilege Object
NOTE: A Privilege Object must be created in the same domain as the related
Association Object.
1 In the Console Root (MMC) window, right-click a container.
2 Select New ï‚® Dell RAC Object .
The New Object window appears.
Using the CMC Directory Service
3 Type a name for the new object.
4 Select Privilege Object .
5 Click OK .
6 Right-click the privilege object that you created, and select Properties .
7 Click the RAC Privileges tab and select the privileges that you want the user to have. For more information about CMC user privileges,
Creating an Association Object
The Association Object is derived from a Group and must contain a Group
Type. The Association Scope specifies the Security Group Type for the
Association Object. When you create an Association Object, choose the
Association Scope that applies to the type of objects you intend to add.
For example, if you select Universal , the association objects are only available when the Active Directory Domain is functioning in Native Mode or above.
1 In the Console Root (MMC) window, right-click a container.
2 Select New ï‚® Dell RAC Object .
This opens the New Object window.
3 Type a name for the new object.
4 Select Association Object .
5 Select the scope for the Association Object .
6 Click OK .
Adding Objects to an Association Object
Using the Association Object Properties window, you can associate users or user groups, privilege objects, and RAC devices or RAC device groups. If your system is running Windows 2000 mode or higher, use Universal Groups to span domains with your user or RAC objects.
You can add groups of Users and RAC devices. The procedure for creating
Dell-related groups and non-Dell-related groups is identical.
Adding Users or User Groups
1 Right-click the Association Object and select Properties .
Using the CMC Directory Service 263
2 Select the Users tab and click Add .
3 Type the user or User Group name and click OK .
Click the Privilege Object tab to add the privilege object to the association that defines the user’s or user group’s privileges when authenticating to a
RAC device. Only one privilege object can be added to an Association Object.
Adding Privileges
1 Select the Privileges Object tab and click Add .
2 Type the Privilege Object name and click OK .
Click the Products tab to add one or more RAC devices to the association.
The associated devices specify the RAC devices connected to the network that are available for the defined users or user groups. Multiple RAC devices can be added to an Association Object.
Adding RAC Devices or RAC Device Groups
To add RAC devices or RAC device groups:
1 Select the Products tab and click Add.
2 Type the RAC device or RAC device group name and click OK .
3 In the Properties window, click Apply and click OK .
Configuring CMC With Extended Schema Active Directory and the Web
Interface
1 Log in to the CMC Web interface.
2 Select Chassis in the system tree.
3 Click User Authentication ï‚® Directory Services .
The Directory Services page is displayed.
4 Select Microsoft Active Directory (Extended Schema) .
5 In the Common Setting s section: a Verify that the Enable Active Directory check box is checked.
b Type the Root Domain Name .
264 Using the CMC Directory Service
NOTE: The Root domain name must be a valid domain name using the x.y
naming convention, where between characters, and mil, net, or org.
y x is a 1–256 character ASCII string with no spaces
is a valid domain type such as com, edu, gov, int, c Type the Timeout time in seconds. Configuration range:
15–300 seconds. Default: 90 seconds
6 Optional: If you want the directed call to search the domain controller and global catalog, select the Search AD Server to search (Optional) check box, then: a b
In the Domain Controller text field, type the server where your Active
Directory service is installed.
In the Global Catalog text field, type the location of the global catalog on the Active Directory domain controller. The global catalog provides a resource for searching an Active Directory forest.
NOTE: Setting the IP address as 0.0.0.0 disables CMC from searching for a server.
NOTE: You can specify a list of domain controller or global catalog servers separated by commas. CMC allows you to specify up to three IP addresses or host names.
NOTE: Domain controller and global catalog servers that are not correctly configured for all domains and applications may produce unexpected results during the functioning of the existing applications/domains.
7 In the Extended Schema Settings section: a Type the CMC Device Name . The CMC Name uniquely identifies the CMC card in Active Directory. The CMC Name must be the same as the common name of the new CMC object you created in your Domain Controller. The CMC Name must be a 1–256 character
ASCII string with no spaces between characters.
b Type the CMC Domain Name (example: cmc.com
). The CMC
Domain Name is the DNS name (string) of the domain where the
Active Directory CMC object resides. The name must be a valid domain name consisting of x.y
, where x is a 1–256 character ASCII string with no spaces between characters, and y is a valid domain type such as com, edu, gov, int, mil, net, or org.
8 Click Apply to save your settings.
Using the CMC Directory Service 265
NOTE: You must apply your settings before continuing to the next step, in which you navigate to another page. If you do not apply the settings, you lose the settings you entered when you navigate to the next page.
9 In the Manage Certificates section, type the file path of the certificate in the text field, or click Browse to select the certificate file. Click the Upload button to transfer the file to CMC.
NOTE: The File Path value displays the relative file path of the certificate you are uploading. You must type the absolute file path, which includes the full path and the complete file name and file extension.
SSL certificate validation is required by default. There is a new setting in the cfgActiveDirectory RACADM group and within the GUI to disable the certificate check.
CAUTION: Disabling this certificate is risky.
To turn on SSL certificate validation (default): racadm config -g cfgActiveDirectory -o cfgADCertValidationEnable 1
To turn off SSL certificate validation: racadm config -g cfgActiveDirectory -o cfgADCertValidationEnable 0
The SSL certificates for the domain controller must be signed by the root certificate authority. The root certificate authority-signed certificate must be available on the management station accessing CMC.
10 Click Apply . The CMC Web server automatically restarts after you click Apply .
11 Log back in to the CMC Web interface.
12 Select Chassis in the system tree, click the Network tab, then click the
Network subtab. The Network Configuration page is displayed.
13 If Use DHCP (for CMC Network Interface IP Address) is enabled
(checked), do one of the following:
• Select Use DHCP to Obtain DNS Server Addresses to enable the
DNS server addresses to be obtained automatically by the DHCP server., or
266 Using the CMC Directory Service
• Manually configure a DNS server IP address by leaving the Use DHCP to Obtain DNS Server Addresses check box unchecked and then typing your primary and alternate DNS server IP addresses in the fields provided.
14 Click Apply Changes .
The CMC Extended Schema Active Directory feature configuration is complete.
Configuring CMC With Extended Schema Active Directory and RACADM
Using the following commands to configure the CMC Active Directory
Feature with Extended Schema using the RACADM CLI tool instead of the
Web interface.
1 Open a serial/Telnet/SSH text console to CMC, log in, and type: racadm config -g cfgActiveDirectory -o cfgADEnable 1 racadm config -g cfgActiveDirectory -o cfgADType 1 racadm config -g cfgActiveDirectory -o cfgADRacDomain < fully qualified CMC domain name > racadm config -g cfgActiveDirectory -o cfgADRootDomain < fully qualified root domain name > racadm config -g cfgActiveDirectory -o cfgADRacName < CMC common name > racadm sslcertupload -t 0x2 -f < ADS root CA certificate > -r racadm sslcertdownload -t 0x1 -f < CMC SSL certificate >
NOTE: You can use this command through remote RACADM only. For more
information on remote RACADM, see "Accessing RACADM Remotely" on page 74.
Optional: If you want to specify an LDAP or Global Catalog server instead of using the servers returned by the DNS server to search for a user name, type the following command to enable the Specify Server option: racadm config -g cfgActiveDirectory -o cfgADSpecifyServerEnable 1
Using the CMC Directory Service 267
268
NOTE: When you use the Specify Server option, the host name in the certificate authority-signed certificate is not matched against the name of the specified server. This is particularly useful if you are a CMC administrator, because it enables you to enter a host name as well as an IP address.
After you enable the Specify Server option, you can specify an LDAP server and global catalog with IP addresses or fully qualified domain names
(FQDNs) of the servers. The FQDNs consist of the host names and the domain names of the servers.
To specify an LDAP server, type: racadm config -g cfgActiveDirectory -o cfgADDomainController <AD domain controller IP address>
To specify a Global Catalog server, type: racadm config -g cfgActiveDirectory -o cfgADGlobalCatalog <AD global catalog IP address>
NOTE: Setting the IP address as 0.0.0.0 disables CMC from searching for a server.
NOTE: You can specify a list of LDAP or global catalog servers separated by commas. CMC allows you to specify up to three IP addresses or host names.
NOTE: LDAP or LDAPs that are not correctly configured for all domains and applications may produce unexpected results during the functioning of the existing applications/domains.
2 Specify a DNS server using one of the following options:
• If DHCP is enabled on CMC and you want to use the DNS address obtained automatically by the DHCP server, type the following command: racadm config -g cfgLanNetworking -o cfgDNSServersFromDHCP 1
• If DHCP is disabled on CMC, or if DHCP is enabled but you want to specify your DNS IP address manually, type following commands: racadm config -g cfgLanNetworking -o cfgDNSServersFromDHCP 0 racadm config -g cfgLanNetworking -o cfgDNSServer1 <primary DNS IP address>
Using the CMC Directory Service
racadm config -g cfgLanNetworking -o cfgDNSServer2 <secondary DNS IP address>
The Extended Schema feature configuration is complete.
Frequently Asked Questions
Table 8-9. Using CMC With Active Directory: Frequently Asked Questions
Question Answer
Can I log into CMC using
Active Directory across multiple trees?
Yes. The CMC’s Active Directory querying algorithm supports multiple trees in a single forest.
Does the login to CMC using Active
Directory work in mixed mode (that is, the domain controllers in the forest run different operating systems, such as Microsoft Windows
2000 or Windows Server 2003)?
Yes. In mixed mode, all objects used by the
CMC querying process (among user,
RAC Device Object, and Association Object) must be in the same domain.
The Dell-extended Active Directory Users and
Computers Snap-In checks the mode and limits users in order to create objects across domains if in mixed mode.
Does using CMC with
Active Directory support multiple domain environments?
Can these Dell-extended objects (Dell Association Object,
Dell RAC Device, and Dell
Privilege Object) be in different domains?
Yes. The domain forest function level must be in Native mode or Windows 2003 mode.
In addition, the groups among Association
Object, RAC user objects, and RAC Device
Objects (including Association Object) must be universal groups.
The Association Object and the Privilege
Object must be in the same domain.
The Dell-extended Active Directory Users and
Computers Snap-In forces you to create these two objects in the same domain. Other objects can be in different domains.
Are there any restrictions on Domain Controller
SSL configuration?
Yes. All SSL certificates for Active Directory servers in the forest must be signed by the same root certificate authority-signed certificate, because CMC only allows you to upload one trusted certificate authority-signed
SSL certificate.
Using the CMC Directory Service 269
Table 8-9. Using CMC With Active Directory: Frequently Asked Questions (continued)
Question
I created and uploaded a new RAC certificate and now the Web interface does not launch.
Answer
If you use Microsoft Certificate Services to generate the RAC certificate, you may have inadvertently chose User Certificate instead of
Web Certificate when creating the certificate.
To recover, generate a CSR, and then create a new Web certificate from Microsoft
Certificate Services and upload it using the following RACADM commands: racadm sslcsrgen [-g]
[-f {filename}] racadm sslcertupload -t 1 -f
{web_sslcert}
270 Using the CMC Directory Service
Table 8-9. Using CMC With Active Directory: Frequently Asked Questions (continued)
Question
What can I do if I cannot log into CMC using Active Directory authentication?
How do I troubleshoot the issue?
Answer
1
2
Ensure that you use the correct user domain name during a login and not the NetBIOS name.
If you have a local CMC user account, log into CMC using your local credentials.
f
After you are logged in, perform the following steps: a Ensure that you have checked the Enable
Active Directory check box on the CMC
Active Directory configuration page.
b c d e
Ensure that the DNS setting is correct on the CMC Networking configuration page.
Ensure that you have uploaded the Active
Directory certificate from your Active
Directory root certificate authority-signed certificate to CMC.
Check the Domain Controller SSL certificates to ensure that they have not expired.
Ensure that your CMC Name ,
Root Domain Name , and CMC Domain
Name match your Active Directory environment configuration.
Ensure that the CMC password has a maximum of 127 characters. While CMC can support passwords of up to
256 characters, Active Directory only supports passwords that have a maximum length of 127 characters.
Using the CMC Directory Service 271
Configuring Single Sign-On
Microsoft Windows 2000, Windows XP, Windows Server 2003,
Windows Vista, Windows 7, and Windows Server 2008 can use Kerberos, a network authentication protocol, as an authentication method allowing users who have signed in to the domain an automatic or single sign-on to subsequent applications such as Exchange.
Starting with CMC version 2.10, CMC can use Kerberos to support two additional types of login mechanisms—single sign-on and Smart Card login.
For single sign-on login, CMC uses the client system’s credentials, which are cached by the operating system after you log in using a valid Active Directory account.
NOTE: Selecting a login method does not set policy attributes with respect to other login interfaces, for example, SSH. You must set other policy attributes for other login interfaces as well. If you want to disable all other login interfaces, navigate to the Services page and disable all (or some) login interfaces.
System Requirements
To use the Kerberos authentication, your network must include:
• DNS server
• Microsoft Active Directory Server
NOTE: If you are using Active Directory on Windows 2003, ensure that you have the latest service packs and patched installed on the client system. If you are using Active Directory on Windows 2008, ensure that you have installed SP1 along with the following hot fixes:
Windows6.0-KB951191-x86.msu for the KTPASS utility. Without this patch the utility generates bad during an LDAP bind.
keytab files.
Windows6.0-KB957072-x86.msu for using GSS_API and SSL transactions
• Kerberos Key Distribution Center (packaged with the Active Directory
Server software).
• DHCP server (recommended).
• The DNS server reverse zone must have an entry for the Active Directory server and CMC.
272 Using the CMC Directory Service
Client Systems
• For only Smart Card login, the client system must have the Microsoft
Visual C++ 2005 redistributable. For more information see www.microsoft.com/downloads/details.aspx?FamilyID=
32BC1BEEA3F9-4C13-9C99-220B62A191EE&displaylang=en
• For Single Sign-On and Smart Card login, the client system must be a part of the Active Directory domain and Kerberos Realm.
CMC
• CMC must have firmware version 2.10 or later
• Each CMC must have an Active Directory account
• CMC must be a part of the Active Directory domain and Kerberos Realm
Configuring Settings
Prerequisites
• The Kerberos realm & Key Distribution Center (KDC) for Active
Directory (AD) has been setup (ksetup).
• A robust NTP and DNS infrastructure to avoid issues with clock drift & reverse lookup.
• The CMC standard schema role group with authorized members.
Configuring Active Directory
On the CMC Properties dialog box under the Accounts options section, configure these settings:
• Account is trusted for delegation — Currently CMC does not use forwarded credentials that are created when this option is selected.
You may or may not select this option depending upon other services requirements.
• Account is sensitive and cannot be delegated — You may or may not select this option depending upon other services requirements.
• User Kerberos DES encryption types for the account — Select this option.
• Do not require Kerberos preauthentication — Do not select this option.
Using the CMC Directory Service 273
Run the ktpass utility—part of Microsoft Windows—on the domain controller (Active Directory server) where you want to map CMC to a user account in Active Directory. For example,
C:\>ktpass -princ
HTTP/cmcname.domain_name.com@REALM_NAME.COM -mapuser dracname -crypto DES-CBC-MD5 -ptype KRB5_NT_PRINCIPAL
-pass * -out c:\krbkeytab
NOTE: The cmcname.domainname.com
must be lower case as required by RFC and the REALM name, @REALM_NAME must be uppercase. In addition,
CMC supports the DES-CBC-MD5 type of cryptography for Kerberos authentication.
This procedure produces a keytab file that you must upload to CMC.
NOTE: The keytab contains an encryption key and must be kept secure. For more information on the ktpass utility, see the Microsoft website at: technet2.microsoft.com/windowsserver/en/library/64042138-9a5a-4981-84e9d576a8db0d051033.mspx?mfr=true.
Configuring CMC
NOTE: The configuration steps described in this section apply only to the CMC's
Web access.
Configure CMC to use the Standard Schema role group(s) set up in Active
Directory. For more information, see "Configuring Standard Schema Active
Directory to Access CMC" on page 244.
Uploading the Kerberos Keytab File
The Kerberos keytab file serves as the CMC's user name and password credentials to the Kerberos Data Center (KDC), which in turns allows access to the Active Directory. Each CMC in the Kerberos realm must be registered with the Active Directory and must have a unique keytab file.
274 Using the CMC Directory Service
To upload the keytab file:
1 Navigate to the User Authentication tab ï‚® Directory Services subtab.
Ensure that Microsoft Active Directory Standard or Extended Schema is selected. If not, select your preference and click Apply .
2 Click Browse on the Kerberos Keytab Upload section, navigate to the folder where the keytab file is saved and click Upload .
When the upload is complete, a message box is displayed indicating a successful or failed upload.
Enabling Single Sign-On
1 Click Chassis Management Controller Network Security tab ï‚® Active
Directory ï‚® Configure Active Directory .
The Active Directory Configuration and Management page is displayed.
2 On the Active Directory Configuration and Management page, select:
• Single Sign-On — this option enables you to log in to CMC using the cached credentials obtained when you log in to the Active Directory.
NOTE: All command line out-of-band interfaces including secure shell (SSH),
Telnet, Serial, and remote RACADM remain unchanged for this option.
3 Scroll to the bottom of the page and click Apply .
You can test the Active Directory using Kerberos authentication by using the
CLI command test feature: testfeature -f adkrb -u < user >@< domain > where user is a valid Active Directory user account.
A command success indicates that CMC is able to acquire Kerberos credentials and access the user's Active Directory account. If the command is not successful, resolve the error and repeat the command. For more information, see Command Line Reference Guide for iDRAC6 and CMC on support.dell.com/manuals .
Using the CMC Directory Service 275
Configuring the Browser For Single Sign-On Login
Single Sign-on is supported on Internet Explorer versions 6.0 and later and
Firefox versions 3.0 and later.
NOTE: The following instructions are applicable only if CMC uses Single Sign-On with Kerberos authentication.
Internet Explorer
1 In the Internet Explorer, select Tools ï‚®ï€ Internet Options .
2 On the Security tab, under Select a zone to view or change security settings , select Local Intranet .
3 Click Sites .
The Local Intranet dialog box is displayed.
4 Click Advanced .
The Local Intranet Advance Settings dialog box is displayed.
5 In the Add this site to the zone , type the name of CMC and the domain it belongs to and click Add .
NOTE: You can use a wildcard (*) to specify all devices/users in that domain.
Mozilla Firefox
1 In Firefox, type about:config in the Address bar.
NOTE: If the browser displays the This might void your warranty warning, click I'll be careful. I promise.
2 In the Filter text box, type negotiate .
The browser displays a list of preference names limited to those containing the word negotiate.
3 From the list, double-click network.negotiate-auth.trusted-uris .
4 In the Enter string value dialog box, type the CMC's domain name and click OK .
276 Using the CMC Directory Service
Logging into CMC Using Single Sign-On
NOTE: You cannot use the IP address to log into the Single Sign-On or Smart Card login. Kerberos validates your credentials against the Fully Qualified Domain Name
(FQDN).
1 Log into the client system using your network account.
2 Access the CMC Web page using https://<
cmcname.domain-name
>
For example, cmc-6G2WXF1.cmcad.lab
where cmc-6G2WXF1 is the cmc-name cmcad.lab
is the domain-name.
NOTE: If you changed the default HTTPS port number (port 80), access the
CMC Web page using the
cmcname
name, and
<cmcname.domain-name>:<port number>
is the CMC host name for CMC,
port number domain-name
is the HTTPS port number.
, where
is the domain
The CMC Single Sign-On page is displayed.
3 Click Login .
CMC logs you in, using the Kerberos credentials that were cached by your browser when you logged in using your valid Active Directory account. If the login fails, the browser is redirected to the normal CMC login page.
NOTE: If you did not log in to the Active Directory domain and are using a browser other then Internet Explorer, the login fails and the browser only displays a blank page.
Using the CMC Directory Service 277
Configuring Smart Card Two-Factor
Authentication
Traditional authentication schemes use user name and password to authenticate users. Two-factor-authentication, on the other hand, provides a higher-level of security by requiring users to have a password or PIN and a physical card containing a private key or digital certificate. Kerberos, a network authentication protocol, uses this two-factor authentication mechanism allowing systems to prove their authenticity. Microsoft
Windows 2000, Windows XP, Windows Server 2003, Windows Vista, and Windows Server 2008 use Kerberos as their preferred authentication method. Starting with CMC version 2.10, CMC can use Kerberos to support
Smart Card login.
NOTE: Selecting a login method does not set policy attributes with respect to other login interfaces, for example, SSH. You must set other policy attributes for other login interfaces as well. If you want to disable all other login interfaces, navigate to the Services page and disable all (or some) login interfaces.
System Requirements
The "System Requirements" on page 272 for Smart Card are the same as
Single Sign-On.
Configuring Settings
The "Prerequisites" on page 273 for Smart Card are the same as Single Sign-
On.
278 Using the CMC Directory Service
Configuring Active Directory
1 Set up Kerberos realm & Key Distribution Center (KDC) for Active
Directory, if not already configured (ksetup).
NOTE: Ensure a robust NTP and DNS infrastructure to avoid issues with clock drift & reverse lookup.
2 Create Active Directory users for each CMC, configured to use
Kerberos DES encryption but not pre-authentication.
3 Register the CMC users to the Key Distribution Center with Ktpass
(this also outputs a key to upload to CMC).
Configuring CMC
NOTE: The configuration steps described in this section apply only to the CMC's
Web access.
Configure CMC to use the Standard Schema role group(s) set up in Active
Directory. For more information, see "Configuring Standard Schema Active
Directory to Access CMC" on page 244.
Uploading the Kerberos Keytab File
The Kerberos keytab file serves as the CMC's user name and password credentials to the Kerberos Data Center (KDC), which in turns allows access to the Active Directory. Each CMC in the Kerberos realm must be registered with the Active Directory and must have a unique keytab file.
To upload the keytab file:
1 Navigate to the User Authentication tab ï‚®ï€ Directory Services subtab.
Ensure that Microsoft Active Directory Standard or Extended Schema is selected. If not, select your preference and click Apply .
2 Click Browse in the Kerberos Keytab Upload section, navigate to the folder where the keytab file is saved and click Upload .
When the upload is complete, a message box is displayed indicating a successful or failed upload.
Using the CMC Directory Service 279
Enabling Smart Card Authentication
1 Navigate to the User Authentication tab ï‚® Directory Services subtab.
Ensure that Microsoft Active Directory Standard or Extended Schema is selected.
2 In the Common Settings Section , select:
• Smart Card — this option requires that you insert a Smart Card into reader and enter the PIN number.
NOTE: All command line out-of-band interfaces including secure shell (SSH),
Telnet, Serial, and remote RACADM remain unchanged for this option.
3 Scroll to the bottom of the page and click Apply .
You can test the Active Directory using Kerberos authentication by using the
CLI command testfeature.
Type: testfeature -f adkrb -u < user >@< domain > where user is a valid Active Directory user account.
A command success indicates that CMC is able to acquire Kerberos credentials and access the user's Active Directory account. If the command is not successful, resolve the error and repeat the command. For more information, see the RACADM command testfeature documentation.
Configuring the Browser For Smart Card Login
Mozilla Firefox
CMC 2.10 does not support Smart Card login through the Firefox browser.
Internet Explorer
Ensure that the Internet Browser is configured to download Active-X plug-ins.
280 Using the CMC Directory Service
Logging into CMC Using Smart Card
NOTE: You cannot use the IP address to log into the Single Sign-On or
Smart Card login. Kerberos validates your credentials against the Fully
Qualified Domain Name (FQDN).
1 Log into the client system using your network account.
2 Access the CMC Web page using https://<
cmcname.domain-name
>
For example, cmc-6G2WXF1.cmcad.lab
where cmc-6G2WXF1 is the cmc-name cmcad.lab
is the domain-name.
NOTE: If you changed the default HTTPS port number (port 80), access the
CMC Web page using
<cmcname.domain-name>:<port number>
, where
cmcname
is the CMC host name for CMC,
domain-name
is the domain name, and
port number
is the HTTPS port number.
The CMC Single Sign-On page is displayed prompting you to insert the Smart Card.
3 Insert the Smart Card into the reader and click OK .
The PIN pop-up dialog box is displayed.
4 Optionally, select a session timeout. This is the amount of time you stay logged in with no activity. The default value is defined as the Web Service
Idle Timeout. See Configuring Services for more details.
5 Enter the PIN and click OK .
Troubleshooting the Smart Card Login
The following tips help you to debug an inaccessible Smart Card:
ActiveX plug-in is unable to detect the Smart Card reader
Ensure that the Smart Card is supported on the Microsoft Windows operating system. Windows supports a limited number of Smart Card cryptographic service providers (CSPs).
Tip : As a general check to see if the Smart Card CSPs are present on a particular client, insert the Smart Card in the reader at the Windows login
Using the CMC Directory Service 281
(Ctrl-Alt-Del) screen and check to see if Windows detects the Smart Card and displays the PIN dialog-box.
Incorrect Smart Card PIN
Check to see if the Smart Card has been locked out due to too many attempts with an incorrect PIN. In such cases, the issuer of the Smart Card in the organization is able to help you get a new Smart Card.
Unable to Log into CMC as an Active Directory User
If you cannot log into CMC as an Active Directory user, try logging into
CMC without enabling the Smart Card logon. You also have the option of disabling the Smart Card Logon through the local RACADM using the following commands: racadm config -g cfgActiveDirectory -o cfgADSCLEnable 0 racadm config -g cfgActiveDirectory -o cfgADSSOEnable 0
Using CMC with Generic LDAP
A CMC administrator can now integrate the LDAP server user logins with
CMC. This integration requires configuration on both LDAP server and
CMC. On the LDAP server, a standard group object is used as a role group. A user who has CMC access becomes a member of the role group.Privileges are still stored on CMC for authorization similar to the working of the Standard
Schema setup with Active Directory support.
To enable the LDAP user to access a specific CMC card, the role group name and its domain name must be configured on the specific CMC card. You can
configure a maximum of five role groups in each CMC. Table 5-41shows the
privileges level of the role groups and Table 8-1 shows the default role group
settings.
282 Using the CMC Directory Service
Figure 8-5. Configuration of CMC with Generic LDAP
Configuration on Generic
LDAP Side
Configuration on
CMC Side
Role
Group
Role
Group Name and Domain
Name
Role
Definition
User
Configuring the Generic LDAP Directory to Access CMC
The CMC's Generic LDAP implementation uses two phases in granting access to a user. Phase 1 begins with user authentication, followed by phase 2 for user authorization.
Authentication and Authorization of the LDAP Users
Some directory servers require a bind before any searches can be performed against a specific LDAP server. The steps for authentication are:
1 Optionally bind to the Directory Service. The default is an anonymous bind.
2 Search for the user based upon their user login. The default attribute is uid .
3 If more than one object is found, then the process returns an error.
Using the CMC Directory Service 283
4 Unbind and perform a bind with the user's DN and password.
5 If the bind fails, then the login fails.
If these steps succeed then the user is considered authenticated. The next phase is authorization. CMC stores a maximum of 5 groups and their corresponding privileges. A user has the option to be added to multiple groups within the directory service. If the user is a member of multiple groups, then the user obtains the privileges of all their groups.
The authorization steps are:
1 Search through each configured group for the user's DN within the member or uniqueMember attributes. This field can be configured by the administrator.
2 For every group the user is a member of, add their privileges together.
Configuring Generic LDAP Directory Service Using CMC Web-Based
Interface
You can use the Generic Lightweight Directory Access Protocol (LDAP)
Service to configure your software to provide access to CMC. LDAP allows you to add and control the CMC user privileges of your existing users.
NOTE: To configure LDAP settings for CMC, you must have Chassis Configuration
Administrator privilege.
For more information about LDAP configuration configuring Generic LDAP,
see "Using CMC with Generic LDAP" on page 282.
To view and configure LDAP, follow these steps:
1 Log in to the Web interface.
2 Click the User Authentication tab, and then click the Directory Services subtab. The Directory Services page appears.
3 Click the radio button associated with Generic LDAP.
4 Configure the options shown and click Apply .
The following configuration options are available.
284 Using the CMC Directory Service
Table 8-10. Common Settings
Setting
Generic LDAP Enabled
Use Distinguished Name to Search Group
Membership
Enable SSL Certificate
Validation
Bind DN
Description
Enables the generic LDAP service on CMC.
Specifies the distinguished name (DN) of LDAP groups whose members are allowed access to the device.
Password
Base DN to Search
Attribute of User Login
Attribute of Group
Membership
Search Filter
If checked, CMC uses the CA certificate to validate the
LDAP server certificate during SSL handshake.
Specifies the distinguished name of a user used to bind to the server when searching for the login user's DN. If not provided an anonymous bind is used.
A bind password to use in conjunction with the bind
DN.
NOTE: The bind password is sensitive data, and must be properly protected.
The DN of the branch of the directory where all searches must start from.
Specifies the attribute to search for. If not configured, the default is to use uid. It is recommended to be unique within the chosen base DN, otherwise a search filter must be configured to ensure the uniqueness of the login user.If the user DN cannot be uniquely identified by searching the combination of attribute and search filter, login fails with an error.
Specifies the LDAP attribute that is used to check for group membership. This must be an attribute of the group class. If not specified, the member and unique member attributes are used.
Specifies a valid LDAP search filter. This is used if the user attribute cannot uniquely identify the login user within the chosen base DN. If not provided, defaults to
(objectClass=*), which searches for all objects in the tree. The maximum length of this property is 1024 characters.
Using the CMC Directory Service 285
286
Table 8-10. Common Settings (continued)
Setting Description
Network Timeout
(seconds)
Sets the time in seconds after which an idle LDAP session is automatically closed.
Search Timeout (seconds) Sets the time in seconds after which a search is automatically closed.
Selecting Your LDAP Servers
You can configure the server to use with Generic LDAP in two ways. Static
Servers allows the administrator to place a FQDN or IP address within the field. Alternatively, a list of LDAP servers can be retrieved by looking up their
SRV record within the DNS.
The following are the properties in the LDAP Servers section:
• Use Static LDAP Servers — Selecting this option causes the LDAP service to use the specified servers with the port number provided (see details below).
NOTE: You must select Static or DNS.
• LDAP Server Address — Specify the FQDN or IP of the LDAP server. To specify multiple, redundant LDAP servers that serve the same domain, provide the list of all servers separated by comma. CMC tries to connect to each server in turn, until it makes a successful connection.
• LDAP Server Port — Port of LDAP over SSL, default to 636 if not configured. Non-SSL port is not supported in CMC version 3.0 as the password cannot be transported without SSL.
• Use DNS to find LDAP Servers — Selecting this option causes LDAP to use the search domain and the service name through DNS. You must select Static or DNS.
The following DNS query is performed for SRV records:
_<Service Name>._tcp.<Search Domain> where < Search Domain > is the root level domain to use within the query and
< Service Name > is the service name to use within the query. For example:
_ldap._tcp.dell.com
where ldap is the service name and dell.com
is the search domain.
Using the CMC Directory Service
Managing LDAP Group Settings
The table in the Group Settings section lists role groups, displaying associated names, domains, and privileges for any role groups that are already configured.
• To configure a new role group, click a role group name that does not have a name, domain, and privilege listed.
• To change the settings for an existing role group, click the role group name.
When you click a role group name, the Configure Role Group page appears.
Help for that page is available through the Help link at the top right corner of the page.
Managing LDAP Security Certificates
This sections displays the properties for the LDAP certificate recently uploaded to CMC. If you uploaded a certificate, use this information to verify that the certificate is valid and has not expired.
NOTE: By default, CMC does not have a certificate authority-issued server certificate for Active Directory. You must upload a current, certificate authoritysigned server certificate.
The following properties for the certificate are displayed:
• Serial Number - The certificate's serial number.
• Subject Information - The certificate's subject (name of the person or company certified).
• Issuer Information - The certificate's issuer (name of the Certificate
Authority.
• Valid From - The starting date of the certificate.
• Valid To - The expiry date of the certificate.
Use the following controls to upload and download this certificate:
• Upload - Initiates the upload process for the certificate. This certificate, which you obtain from your LDAP server, grants access to CMC.
• Download - Initiates the download process. You are prompted for the location to save the file. When you select this option and click Next , a File
Download dialog box appears. Use this dialog box to specify a location on your management station or shared network for the server certificate.
Using the CMC Directory Service 287
288
Configuring Generic LDAP Directory Service Using RACADM
NOTE: This feature supports both IPv4 and IPv6.
There are many options to configure LDAP logins. In most of the cases, some options can be used with their default settings.
NOTE: It is highly recommended to use the 'racadm testfeature -f LDAP' command to test the LDAP settings for first time setups. This feature supports both IPv4 and
IPv6.
Required property changes include enabling LDAP logins, setting the server
FQDN or IP, and configuring the base DN of the LDAP server.
• $ racadm config -g cfgLDAP -o cfgLDAPEnable 1
• $ racadm config -g cfgLDAP -o cfgLDAPServer
192.168.0.1
• $ racadm config -g cfgLDAP -o cfgLDAPBaseDN dc= company,dc=com
CMC can be configured to optionally query a DNS server for SRV records. If the cfgLDAPSRVLookupEnable property is enabled the cfgLDAPServer property is ignored. The following query is used to search the DNS for SRV records:
_ldap._tcp.domainname.com
ldap in the above query is the cfgLDAPSRVLookupServiceName property.
cfgLDAPSRVLookupDomainName is configured to be domainname.com
.
Usage
To login to CMC using an LDAP user, use the username at the login prompt and the user's password at the password prompt. If a LDAP user cannot be logged in for any reason, CMC falls back and attempts to use a local login with the same username and password. This allows a login if network connectivity is broken or the LDAP server is not reachable.
Getting Help
CMC's tracelog contains some information on why a user may fail to login.
To triage LDAP login failures, it is recommended to use the racadm testfeature -f LDAP command with the debugging turned on.
Using the CMC Directory Service
9
Power Management
Overview
The Dell PowerEdge M1000e server enclosure is the most power-efficient modular server enclosure in the market. It is designed to include highlyefficient power supplies and fans, has an optimized layout so that air flows more easily through the system, and contains power-optimized components throughout the enclosure. The optimized hardware design is coupled with sophisticated power management capabilities built into the Chassis
Management Controller (CMC), power supplies, and iDRAC to allow you to further enhance power efficiency and to have full control over your power environment.
The PowerEdge M1000e modular enclosure takes in AC power and distributes the load across all active internal power supply units (PSUs).
The system can deliver up to 11637 Watts of AC power that is allocated to server modules and the associated enclosure infrastructure.
NOTE: Actual power delivery is based on configuration and workload.
The Power Management features of the M1000e help administrators configure the enclosure to reduce power consumption and to tailor power management to their unique requirements and environments.
The PowerEdge M1000e enclosure can be configured for any of three redundancy policies that affect PSU behavior and determine how chassis
Redundancy state is reported to administrators.
AC Redundancy Mode
The purpose of the AC redundancy policy is to enable a modular enclosure system to operate in a mode in which it can tolerate AC power failures.
These failures may originate in the AC power grid, the cabling and delivery, or a PSU itself.
Power Management 289
When you configure a system for AC redundancy, the PSUs are divided into grids: PSUs in slots 1, 2, and 3 are in the first grid while PSUs in slots 4, 5, and
6 are in the second grid. CMC manages power so that if there is a failure of either grid the system continues to operate without any degradation. AC redundancy also tolerates failures of individual PSUs.
NOTE: Since one role of AC redundancy is to provide seamless server operation despite failure of a whole power grid, the most power is available to maintain AC redundancy when the capacities of the two grids are approximately equal.
NOTE: AC redundancy is only met when the load requirements do not exceed the capacity of the weakest power grid.
AC Redundancy Levels
One PSU in each grid is the minimum configuration necessary for use as AC redundant. Additional configurations are possible with every combination that has at least one PSU in each grid. However, to make the maximum power available for use, the total power of the PSUs in each leg should be as close to equal as practical. The upper limit of power while maintaining AC redundancy is the power available on the weakest of the two grids.
If for some reason CMC is unable to maintain AC redundancy then E-mail and/or SNMP alerts are sent to administrators if the Redundancy Lost event is configured for alerting.
Figure 9-1. Figure 8-2. 2 PSUs per grid and a power failure on grid 1
AC Power Grid #1
AC Power Grid #2
Power
Supply
#1
Power
Supply
#2
Empty
Slot
#3
Power
Supply
#4
Power
Supply
#5
Empty
Slot
#6
Chassis DC Power Bus
290 Power Management
NOTE: In the event of a single PSU failure in this configuration, the remaining PSUs in the failing grid are marked as Online. In this state, any of the remaining PSUs can fail without interrupting operation of the system. If a PSU fails, the chassis health is marked non-critical. If the smaller grid cannot support the total chassis power allocations then AC redundancy status is reported as No Redundancy and Chassis health is displayed as Critical.
Power Supply Redundancy Mode
The power supply redundancy mode is useful when redundant power grids are not available, but you may want to be protected against a single PSU failure bringing down your servers in a modular enclosure. The highest capacity PSU is kept in online reserve for this purpose. This forms a Power Supply redundancy pool.
PSUs beyond those required for power and redundancy are still available and is added to the pool in the event of a failure.
Unlike AC redundancy, when power supply redundancy is selected CMC does not require the PSU units to be present in any specific PSU slot positions.
NOTE: Dynamic Power Supply Engagement (DPSE) allows PSUs to be placed in standby. The standby state indicates a physical state, that of not supplying power.
When you enable DPSE, the extra PSUs may be placed in Standby mode to increase efficiency and save power.
Figure 9-2. Power Supply Redundancy: Totally 4 PSUs with a failure of one PSU.
Power
Supply
#1
Power
Supply
#2
Power
Supply
#3
Power
Supply
#4
Empty
Slot
#5
Empty
Slot
#6
Chassis DC Power Bus
Dual or Single Power Grid:
Power Supply Redundancy protects against failure of a single power supply.
Power Management 291
No Redundancy Mode
The no redundancy mode is the factory default setting for 3 PSU configuration and indicates that the chassis does not have any power redundancy configured. In this configuration, the overall redundancy status of the chassis always indicates No Redundancy .
CMC does not require the PSU units to be present in any specific PSU slot positions when No Redundancy is configured.
NOTE: All PSUs in the chassis are Online if DPSE is disabled when in No
Redundancy mode. When DPSE is enabled all active PSUs in the chassis are listed as Online and additional PSUs may be turned to Standby to increase the system's power efficiency.
Figure 9-3. No Redundancy with three PSUs in the chassis
AC Power Grid #1
Power
Supply
#1
Power
Supply
#2
Power
Supply
#3
Empty
Slot
#4
Empty
Slot
#5
Empty
Slot
#6
Chassis DC Power Bus
Single Power Grid:
No protection against grid or power supply failure
A PSU failure brings other PSUs out of Standby mode, as needed, to support the chassis power allocations. If you have 4 PSUs, and require only three, then in the event that one fails, the fourth PSU is brought online. A chassis can have all 6 PSUs online.
292 Power Management
When you enable DPSE, the extra PSUs may be placed in Standby mode to
increase efficiency and save power. For more information, see "Dynamic
Power Supply Engagement" on page 296.
Power Budgeting for Hardware Modules
Figure 9-4 illustrates a chassis that contains a six-PSU configuration.
The PSUs are numbers 1-6, starting on the left-side of the enclosure.
Figure 9-4. Chassis With Six-PSU Configuration
PSU1 PSU2 PSU3 PSU4 PSU5 PSU6
CMC maintains a power budget for the enclosure that reserves the necessary wattage for all installed servers and components.
CMC allocates power to the CMC infrastructure and the servers in the chassis. CMC infrastructure consists of components in the chassis, such as fans, I/O modules, and iKVM (if present). The chassis may have up to 16 servers that communicate to the chassis through the iDRAC. For more information, see the iDRAC User’s Guide at support.dell.com/manuals .
Power Management 293
294 iDRAC provides CMC with its power envelope requirements before powering up the server. The power envelope consists of the maximum and minimum power requirements necessary to keep the server operating. iDRAC’s initial estimate is based on its initial understanding of components in the server.
After operation commences and further components are discovered, iDRAC may increase or decrease its initial power requirements.
When a server is powered-up in an enclosure, the iDRAC software re-estimates the power requirements and requests a subsequent change in the power envelope.
CMC grants the requested power to the server, and the allocated wattage is subtracted from the available budget. Once the server is granted a power request, the server's iDRAC software continuously monitors the actual power consumption. Depending on the actual power requirements, the iDRAC power envelope may change over time. iDRAC requests a power step-up only if the servers are fully consuming the allocated power.
Under heavy load the performance of the server’s processors may be degraded to ensure power consumption stays below the user-configured System Input
Power Cap.
The PowerEdge M1000e enclosure can supply enough power for peak performance of most server configurations, but many available server configurations do not consume the maximum power that the enclosure can supply. To help data centers provision power for their enclosures, the M1000e allows you to specify a System Input Power Cap to ensure that the overall chassis AC power draw stays under a given threshold. CMC first ensures enough power is available to run the fans, IO Modules, iKVM (if present), and CMC itself. This power allocation is called the Input Power Allocated to
Chassis Infrastructure . Following Chassis Infrastructure, the servers in an enclosure are powered up. Any attempt to set a System Input Power Cap below the actual consumption fails.
If necessary for the total power budget to stay below the value of the
System Input Power Cap , CMC allocates servers a value less than their maximum requested power. Servers are allocated power based on their Server
Priority setting, with higher priority servers getting maximum power, priority
2 servers getting power after priority 1 servers, and so on. Lower priority servers may get less power than priority 1 servers based on System Input Max
Power Capacity and the user-configured setting of System Input Power Cap .
Power Management
Configuration changes, such as an additional server in the chassis, may require the System Input Power Cap to be increased. Power needs in a modular enclosure also increase when thermal conditions change and the fans are required to run at higher speed, which causes them to consume additional power. Insertion of I/O modules and iKVM also increases the power needs of the modular enclosure. A fairly small amount of power is consumed by servers even when they are powered down to keep the management controller powered up. Additional servers can be powered up in the modular enclosure only if sufficient power is available. The System Input Power Cap can be increased any time up to a maximum value of 11637 watts to allow the power up of additional servers.
Changes in the modular enclosure that reduce the power allocation are:
• Server power off
• Server
• I/O module
• iKVM removal
• Transition of the chassis to a powered off state
You can reconfigure the System Input Power Cap when chassis is either ON or OFF.
Server Slot Power Priority Settings
CMC allows you to set a power priority for each of the sixteen server slots in an enclosure. The priority settings are 1 (highest) through 9 (lowest). These settings are assigned to slots in the chassis, and the slot's priority is inherited by any server inserted in that slot. CMC uses slot priority to preferentially budget power to the highest priority servers in the enclosure.
According to the default server slot priority setting, power is equally apportioned to all slots. Changing the slot priorities allows administrators to prioritize which servers are given preference for power allocations. If the more critical server modules are left at their default slot priority of 1, and the less critical server modules are changed to lower priority value of 2 or higher, the priority 1 server modules would be powered on first. These higher priority servers would then get their maximum power allocation, while lower priority servers may be not be allocated enough power to run at their maximum performance or they may not even power on at all, depending on how low the system input power cap is set and the server power requirements.
Power Management 295
If an administrator manually powers on the low priority server modules before the higher priority ones, then the low priority server modules are the first modules to have their power allocation lowered down to the minimum value, in order to accommodate the higher priority servers. So after the available power for allocation is exhausted, then CMC reclaims power from lower or equal priority servers until they are at their minimum power level.
NOTE: I/O modules, fans, and iKVM (if present) are given the highest priority. CMC reclaims power only from lower priority devices to meet the power needs of a higher priority module or server.
Dynamic Power Supply Engagement
Dynamic Power Supply Engagement (DPSE) mode is disabled by default.
DPSE saves power by optimizing the power efficiency of the PSU’s supplying power to the chassis. This also results in increased PSU life, and reduced heat generation.
CMC monitors total enclosure power allocation, and moves the PSUs into
Standby state, causing the total power allocation of the chassis to be delivered through fewer PSUs. Since the online PSUs are more efficient when running at higher utilization, this improves their efficiency while also improving longevity of the standby PSUs.
To operate remaining PSUs at their maximum efficiency:
• No Redundancy mode with DPSE is highly power efficient, with optimal
PSUs online. PSUs that are not needed are placed in standby mode.
• PSU Redundancy mode with DPSE also provides power efficiency. At least two supplies are online, with one PSU required to power the configuration and one to provide redundancy in case of PSU failure. PSU Redundancy mode offers protection against the failure of any one PSU, but offers no protection in the event of an AC grid loss.
• AC Redundancy mode with DPSE, where at least two of the supplies are active, one on each power grid, provides a good balance between efficiency and maximum availability for a partially-loaded modular enclosure configuration.
• Disabling DPSE provides the lowest efficiency as all six supplies are active and share the load, resulting in lower utilization of each power supply.
296 Power Management
DPSE can be enabled for all three power supply redundancy configurations explained above — No Redundancy , Power Supply Redundancy , and AC
Redundancy .
• In a No Redundancy configuration with DPSE, the M1000e can have up to five power supply units in Standby state. In a six PSU configuration, some PSU units are placed in Standby and stay unutilized to improve power efficiency. Removal or failure of an online PSU in this configuration cause a PSU in Standby state to become Online ; however, standby PSUs can take up to 2 seconds to become active, so some server modules may lose power during the transition in the No Redundancy configuration.
NOTE: In a three PSU configuration, server load may prevent any PSUs from transitioning to Standby.
• In a Power Supply Redundancy configuration, the enclosure always keeps an additional PSU powered on and marked Online in addition to the PSUs required to power the enclosure. Power utilization is monitored and up to four PSUs could be moved to Standby state depending on the overall system load. In a six PSU configuration, a minimum of two power supply units are always powered on.
Since an enclosure in the Power Supply Redundancy configuration always has an extra PSU engaged, the enclosure can tolerate the loss of one online
PSU and still have enough power for the installed server modules. The loss of the online PSU causes a standby PSU to come online. Simultaneous failure of multiple PSUs may result in the loss of power to some server modules while the standby PSUs are powering up.
• In AC Redundancy configuration, all power supplies are engaged at chassis power up. Power utilization is monitored, and if system configuration and power utilization allows, PSUs are moved to the Standby state. Since the
Online status of PSUs in a grid mirrors that of the other grid, the enclosure can sustain the loss of power to an entire grid with no interruption of power to the enclosure.
An increase in power demand in the AC Redundancy configuration cause the engagement of PSUs from the Standby state. This maintains the mirrored configuration needed for dual-grid redundancy.
NOTE: With DPSE Enabled, the Standby PSUs are brought Online to reclaim power if power demand increases in all three Power Redundancy policy modes.
Power Management 297
298
Redundancy Policies
Redundancy policy is a configurable set of properties that determine how
CMC manages power to the chassis. The following redundancy policies are configurable with or without dynamic PSU engagement:
• AC Redundancy
• Power Supply Redundancy
• No Redundancy
The default redundancy configuration for a chassis depends on how many
PSUs it contains, as shown in Table 9-1.
Table 9-1. Default Redundancy Configuration
PSU Configuration Default Redundancy
Policy
Six PSUs
Three PSUs
AC Redundancy
No Redundancy
Default Dynamic PSU Engagement
Setting
Disabled
Disabled
AC Redundancy
In AC Redundancy mode with six PSUs, all six PSUs are active. The three
PSUs on the left must connect to one AC power grid, while the three PSUs on the right connect to another AC power grid.
CAUTION: To avoid a system failure and for AC Redundancy to work effectively, there must be a balanced set of PSU properly cabled to separate AC grids.
If one AC grid fails, the PSUs on the functioning AC grid take over without interruption to the servers or infrastructure.
CAUTION: In AC redundancy mode, you must have balanced sets of PSUs (at least one PSU in each grid). If this condition is not met, AC redundancy may not be possible.
Power Supply Redundancy
When power supply redundancy is enabled, a PSU in the chassis is kept as a spare, ensuring that the failure of any one PSU does not cause the servers or chassis to power-down. Power Supply Redundancy mode requires up to four
PSUs. Additional PSUs, if present, are utilized to improve power efficiency of the system if DPSE is enabled. Subsequent failures after loss of redundancy may cause the servers in the chassis to power down.
Power Management
No Redundancy
Power in excess of what is necessary to power the chassis is available, even on a failure, to continue to power the chassis.
CAUTION: The No Redundancy mode uses optimum PSUs when DPSE is enabled for the requirements of the chassis. Failure of a single PSU could cause servers to lose power and data in this mode.
Power Conservation and Power Budget Changes
CMC performs power conservation when the user-configured maximum power limit is reached. When the demand for power exceeds the user configured System Input Power Cap , CMC reduces power to servers in reverse-priority order to free power for higher priority servers and other modules in the chassis.
If all or multiple slots in the chassis are configured with the same priority level, CMC decreases power to servers in increasing slot number order. For example, if the servers in slots 1 and 2 have the same priority level, the power for the server in slot 1 is decreased before that of the server in slot 2.
NOTE: You can assign a priority level to each of the servers in the chassis by giving each server a number from 1 through 9. The default priority level for all servers is 1.
The lower the number, the higher the priority level.
For instructions on assigning server priority levels, see "Using RACADM" on page 323.
You can assign server priority using the GUI:
1 Click Servers in the system tree 
2 Click Power ï‚® Priority .
Power Conservation and Max Conservation Mode
CMC performs maximum power conservation when:
• The user selects maximum conservation mode using the Web interface or
RACADM.
• An automated command line script, issued by a UPS device, selects maximum conservation mode.
Power Management 299
300
In maximum power conservation mode, all servers start functioning at their minimum power levels, and all subsequent server power allocation requests are denied. In this mode, the performance of powered on servers may be degraded. Additional servers cannot be powered on, regardless of server priority.
The system is restored to full performance when the user or an automated command line script clears the maximum conservation mode.
Using the Web Interface
You can select or clear the Max Power Conservation mode using the GUI:
1 Click Chassis Overview in the system tree.
2 Click Power ï‚® Configuration .
3 Select the Max Power Conservation Mode box to enable maximum power conservation and click Apply .
4 Clear the Max Power Conservation Mode box to restore normal operation and click Apply .
Using RACADM
Open a serial/Telnet/SSH console to CMC and log in.
• To enable the maximum power consumption mode, type: racadm config -g cfgChassisPower -o cfgChassisMaxPowerConservationMode 1
• To restore normal operation, type: racadm config -g cfgChassisPower -o cfgChassisMaxPowerConservationMode 0
110V PSUs Operation
Some PSUs support operation with 110V AC input. This input can exceed what is allowed for the branch circuit. If any PSUs are connected to 110V AC, the user needs to set CMC for normal operation of the enclosure. If it is not set and 110V PSUs are detected, all subsequent server power allocation requests are denied. In this case, additional servers cannot be powered on, regardless of their priority. You can set CMC to use 110 V PSUs using the
Web interface or RACADM.
Power Management
Using the Web Interface
Verify that the 110 V circuit is rated for the current expected, and then perform the following steps:
1 Click Chassis Overview in the system tree.
2 Click Power ï‚® Configuration .
3 Select Allow 110 VAC Operation and click Apply .
Using RACADM
Verify that your 110 V circuit is rated for the expected current, and then perform the following steps:
1 Open a serial/Telnet/SSH text console to CMC and log in.
2 Enable 110 VAC PSUs: racadm config -g cfgChassisPower -o cfgChassisAllow110VACOperation 1
Server Performance Over Power Redundancy
When enabled, this option favors server performance and server powerup, over maintaining power redundancy. When disabled, the system favors power redundancy over server performance. When disabled, then if the power supplies in the chassis do not provide sufficient power, both for redundancy, as well as full performance, then in order to preserve redundancy, some servers may not be:
• Granted sufficient power for full performance.
• Powered on.
Using the Web Interface
To enable Server Performance Over Power Redundancy, perform the following steps:
1 Click Chassis Overview in the system tree.
2 Click Power ï‚® Configuration .
3 Select Server Performance Over Power Redundancy and click Apply .
Power Management 301
To disable Server Performance Over Power Redundancy, perform the following steps:
1 Click Chassis Overview in the system tree.
2 Click Power ï‚® Configuration .
3 Clear Server Performance Over Power Redundancy and click Apply .
Using RACADM
To enable Server Performance Over Power Redundancy, perform the following steps:
1 Open a serial/Telnet/SSH text console to CMC and log in.
2 Enable Server Performance Over Power Redundancy: racadm config -g cfgChassisPower -o cfgChassisPerformanceOverRedundancy 1
To disable Server Performance Over Power Redundancy, perform the following steps:
1 Open a serial/Telnet/SSH text console to CMC and log in.
2 Disable Server Performance Over Power Redundancy: racadm config -g cfgChassisPower -o cfgChassisPerformanceOverRedundancy 0
Remote Logging
Power consumption can be reported to a remote syslog server. Total chassis power consumption, minimum, maximum, and average power consumption over a collection period can be logged. For more information on enabling this feature and configuring the collection/logging interval, see related sections below.
Using the Web Interface
You can enable power remote logging using the GUI. To do so, log in to the
GUI, and do the following:
1 Click Chassis Overview in the system tree.
2 Click Power ï‚® Configuration .
302 Power Management
3 Select Power Remote Logging , to enable you to log power events to a remote host.
4 Specify the required logging interval (1–1440 minutes).
5 Click Apply , to save changes.
Using RACADM
Open a serial, Telnet or SSH text console to CMC, log in, and configure power remote logging as shown:
1 To enable the power remote logging feature, enter the following command: racadm config -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingEnabled 1
2 To specify the desired logging interval, enter the following command: racadm config -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingInterval n where n is 1-1440 minutes.
3 To determine if the power remote logging feature is enabled, enter the following command: racadm getconfig -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingEnabled
4 To determine the power remote logging interval, enter the following command: racadm getconfig -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingInterval
NOTE: The power remote logging feature is dependent on remote syslog hosts having been previously configured. Logging to one or more remote syslog hosts must be enabled, otherwise power consumption is logged. This can be done either through the web GUI or the RACADM CLI. See the remote syslog configuration instructions for more details.
Power Management 303
PSU Failure With Degraded or No Redundancy Policy
CMC decreases power to servers when an insufficient power event occurs, such as a PSU failure. After decreasing power on servers, CMC re-evaluates the power needs of the chassis. If power requirements are still not met, CMC powers off lower priority servers.
Power for higher priority servers is restored incrementally while power needs remain within the power budget.
NOTE:
To set the redundancy policy, see "Configuring Power Budget and
New Server Engagement Policy
When a new server is powered on, CMC may need to decrease power to lower priority servers to allow more power for the new server if adding the new server exceeds the power available for the chassis. This could happen if the administrator has configured a power limit for the chassis that is below what would be required for full power allocation to the servers, or if insufficient power is available for the worst-case power need of all servers in the chassis.
If enough power cannot be freed by reducing the allocated power of the lower priority servers, the new server may not be allowed to power up.
The highest amount of sustained power required to run the chassis and all of the servers, including the new one, at full power is the worst-case power requirement. If that amount of power is available, then no servers are allocated power that is less than the worst-case power needed and the new server is allowed to power up.
If the worst-case power requirement cannot be met, power is reduced to the lower priority servers until enough power is freed to power up the new server.
Table 9-2 describes the actions taken by CMC when a new server is powered
on in the scenario described above.
304 Power Management
Table 9-2. CMC Response When a Server Power-On is Attempted
Worst Case Power is Available
CMC Response
Yes
No
No power conservation is required
Perform power conservation:
• Power required for new server is available
• Power required for new server is not available
Server
Power On
Allowed
Allowed
Disallowed
If a PSU fails, it results in a non-critical health state and a PSU failure event is generated. The removal of a PSU results in a PSU removal event.
If either event results in a loss of redundancy, based on power allocations, a loss of redundancy event is generated.
If the subsequent power capacity or the user power capacity is greater than the server allocations, servers have degraded performance or, in a worse case, servers may be powered down. Both conditions are in reverse-priority order, that is, the lower priority servers are powered down first.
Table 9-3 describes the firmware response to a PSU power down or removal as
it applies to various PSU redundancy configurations.
Table 9-3. Chassis Impact from PSU Failure or Removal
PSU
Configuration
Dynamic PSU
Engagement
AC Redundancy Disabled
Power Supply
Redundancy
Disabled
No Redundancy Disabled
AC Redundancy Enabled
Firmware Response
CMC alerts you of loss of AC Redundancy.
CMC alerts you of loss of Power Supply
Redundancy.
Decrease power to low priority servers, if needed.
CMC alerts you of loss of AC Redundancy. PSUs in standby mode (if any) are turned on to compensate for power budget lost from the PSU failure or removal.
Power Management 305
Table 9-3. Chassis Impact from PSU Failure or Removal (continued)
PSU
Configuration
Power Supply
Redundancy
Dynamic PSU
Engagement
Enabled
No Redundancy Enabled
Firmware Response
CMC alerts you of loss of Power Supply
Redundancy. PSUs in standby mode (if any) are turned on to compensate for power budget lost from PSU failure or removal.
Decrease power to low priority servers, if needed.
PSU Removals With Degraded or No Redundancy Policy
CMC may begin conserving power when you remove a PSU or a PSU
AC cord. CMC decreases power to the lower priority servers until power allocation is supported by the remaining PSUs in the chassis. If you remove more than one PSU, CMC evaluates power needs again when the second PSU is removed to determine the firmware response. If power requirements are still not met, CMC may power off the lower priority servers.
Limits
• CMC does not support automated power-down of a lower priority server to allow power up of a higher priority server; however, you can perform userinitiated power-downs.
• Changes to the PSU redundancy policy are limited by the number of PSUs in the chassis. You can select any of the three PSU redundancy
configuration settings listed in "Redundancy Policies" on page 298.
Power Supply and Redundancy Policy Changes in System Event Log
Changes in the power supply state and power redundancy policy are recorded as events. Events related to the power supply that record entries in the system event log (SEL) are power supply insertion and removal, power supply input insertion and removal, and power supply output assertion and de-assertion.
Table 9-4 lists the SEL entries that are related to power supply changes.
306 Power Management
Table 9-4. SEL Events for Power Supply Changes
Power Supply Event
Insertion
Removal
AC input received
AC input lost
DC output produced
DC output lost
Unacknowledged 110V operation detected
110V operation acknowledged
System Event Log (SEL) Entry power supply presence was asserted power supply presence was de-asserted power supply input lost was de-asserted power supply input lost was asserted power supply failure was de-asserted power supply failure was asserted power supply low input voltage (110) was asserted power supply low input voltage (110) was deasserted
Events related to changes in the power redundancy status that record entries in the SEL are redundancy loss and redundancy regain for the modular enclosure that is configured for either an AC Redundancy power policy or Power Supply
Redundancy
power policy. Table 9-5 lists the SEL entries that are related to
power redundancy policy changes.
Table 9-5. SEL Events for Power Redundancy Status Changes
Power Policy Event
Redundancy lost
Redundancy regained
System Event Log (SEL) Entry redundancy lost was asserted redundancy lost was de-asserted
Power Management 307
Redundancy Status and Overall Power Health
The redundancy status is a factor in determining the overall power health.
When the power redundancy policy is set, for example, to AC Redundancy and the redundancy status indicates that the system is operating with redundancy, the overall power health is typically OK . However, if the conditions for operating with AC redundancy cannot be met, the redundancy status is No , and the overall power health is Critical . This is because the system is not able to operate in accordance with the configured redundancy policy.
NOTE: CMC does not perform a pre-check of these conditions when you change the redundancy policy to or from AC redundancy. So, configuring the redundancy policy may immediately result in redundancy lost or a regained condition.
Configuring and Managing Power
You can use the Web-based and RACADM interfaces to manage and configure power controls on CMC. Specifically, you can:
• View power allocations, consumption, and status for the chassis, servers, and PSUs.
• Configure System Input Power Cap and Redundancy Policy for the chassis.
• Execute power control operations (power-on, power-off, system reset, power-cycle) for the chassis.
Viewing the Health Status of the PSUs
The Power Supply Status page displays the status and readings of the PSUs associated with the chassis.
Using the Web Interface
The PSU health status can be viewed in two ways: from the Chassis Graphics section on the Chassis Status page or the Power Supply Status page.
The Chassis Graphics page provides a graphical overview of all PSUs installed in the chassis.
308 Power Management
To view health status for all PSUs using Chassis Graphics :
1 Log in to the CMC Web interface.
2 The Chassis Status page is displayed. The lower section of Chassis
Graphics depicts the rear view of the chassis and contains the health status of all PSUs. PSU health status is indicated by the color of the PSU subgraphic:
• Green — PSU is present, powered on and communicating with CMC; there is no indication of an adverse condition.
• Amber — Indicates a PSU failure. See the CMC log for details on the failure condition.
• Gray — Occurs during PSU initialization and when the PSU is set to standby, during Chassis power up, or PSU insertion. PSU is present and not powered on. There is no indication of an adverse condition.
3 Use the cursor to hover over the an individual PSU subgraphic and a corresponding text hint or screen tip is displayed. The text hint provides additional information on that PSU.
4 The PSU subgraphic is hyperlinked to the corresponding CMC GUI page to provide immediate navigation to the Power Supply Status page for all PSUs.
To view the health status of the PSU s using Power Supply Status :
1 Log in to the CMC Web interface.
2 Select Power Supplies in the system tree. The Power Supply Status page displays.
Table 9-6 and Table 9-7 provide descriptions of the information provided on
the Power Supply Status page.
Table 9-6. Power Supplies
Item
Name
Present
Description
Displays the name of the power supply unit: PS-[n], where [n] is the power supply number.
Indicates whether the PSU is Present or Absent .
Power Management 309
Table 9-6. Power Supplies (continued)
Item
Health
Power Status
Capacity
Description
OK
Warning
Indicates that the PSU is present and communicating with CMC. In the event of a communication failure between CMC and the power supply, CMC cannot obtain or display health status for the PSU.
Indicates that only Warning alerts have been issued, and corrective action must be taken.
If corrective actions are not taken, it could lead to critical or severe power failures that can affect the integrity of the chassis.
Severe Indicates that at least one Failure alert has been issued for the power supply. Severe status indicates a power failure on the chassis, and corrective action must be taken immediately .
Displays the power state of the power supplies (one of the following): Initializing , Online , Stand By , In Diagnostics , Failed ,
Offline , Unknown , or Absent .
Displays the power supply’s capacity in watts.
Table 9-7. System Power Status
Item
Overall Power
Health
System Power
Status
Redundancy
Description
Displays the health status ( OK, Non-Critical, Critical,
Non-Recoverable, Other, Unknown ) of the power management for the entire chassis.
Displays the power status ( On, Off, Powering On, Powering
Off ) of the chassis.
Displays the power supply redundancy status. Values include:
No : Power Supplies are not redundant.
Yes : Full Redundancy in effect.
310 Power Management
Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type: racadm getpminfo
For more information about getpminfo , including output details, see the
Command Line Reference Guide for iDRAC6 and CMC on the Dell Support website at support.dell.com/manuals .
Viewing Power Consumption Status
CMC provides the actual input power consumption for the entire system on the Power Consumption Status page.
Using the Web Interface
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
1 Log in to the CMC Web interface.
2 Select Chassis Overview in the system tree.
3 Click Power ï‚®ï€ Power Consumption . The Power Consumption page displays.
Table 9-8 through Table 9-11 describe the information displayed on the
Power Consumption page.
NOTE: You can also view the power redundancy status under Power Supplies in the System tree ï‚® Status tab.
Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type: racadm getpminfo
Power Management 311
Table 9-8. Real-Time Power Statistics
Item Description
System Input
Power
Peak System
Power
Peak System
Power Start Time
Peak System
Power Timestamp
Displays the current cumulative power consumption of all modules in the chassis measured from the input side of the PSUs.
The value for system input power is indicated in both watts and
BTU/h units.
Displays the maximum system level input power consumption since the value was last cleared. This property allows you to track the maximum power consumption by the system (chassis and modules) recorded over a period of time. Click the Reset
Peak/Min Power Statistics button below the table to clear this value. The value for peak system power is indicated in both watts and BTU/h units.
Displays the date and time recorded when the peak system power consumption value was last cleared. The timestamp is displayed in the format hh:mm:ss MM/DD/YYYY , where hh is hours (0-24), mm is minutes (00-60), ss is seconds (00-60),
MM is the month (1-12), DD is the day (1-31), and YYYY is the year. This value is reset with the Reset Peak/Min Power
Statistics button and also when CMC resets or fails over.
Displays the date and time recorded when the peak system power consumption value occurred over the time period being recorded.
The timestamp is displayed in the format hh:mm:ss
MM/DD/YYYY , where hh is hours (0–24), mm is minutes
(00–60), ss is seconds (00–60), MM is the month (1–12), DD is the day, 1–31, and YYYY is the year.
Minimum System
Power
Displays the minimum system level AC power consumption value
(in watts) over the time since the user last cleared this value.
This property allows you to track the minimum power consumption by the system (chassis and modules) recorded over a period of time. Click the Reset Peak/Min Power Statistics button below the table to clear this value. The value for minimum system power is displayed in both watts and BTU/h units. This value is reset with the Reset Peak/Min Power
Statistics button and also when CMC resets or fails over.
312 Power Management
Table 9-8. Real-Time Power Statistics (continued)
Item Description
Minimum System
Power Start Time
Displays the date and time recorded when the minimum system power consumption value was last cleared. The timestamp is displayed in the format hh:mm:ss MM/DD/YYYY , where hh is hours (0-24), mm is minutes (00-60), ss is seconds (00-60),
MM is the month (1-12), DD is the day (1-31), and YYYY is the year. This value is reset with the Reset Peak/Min Power
Statistics button and also when CMC resets or fails over.
Minimum System
Power Timestamp
Displays the date and time recorded when the minimum system power consumption occurred over the time period being recorded. The format of the timestamp is the same as described for Peak System Power Timestamp .
System Idle Power Displays the estimated power consumption of the chassis when it is in idle state. The idle state is defined as the state of the chassis while it's ON and all modules are consuming power while in the idle state. This is an estimated value and not a measured value.
It is computed as the cumulative power allocated to chassis infrastructure components (I/O modules, fans, iKVM, iDRAC controllers and front panel LCD) and the minimum power requirement of all servers that have been allocated power and that are in the powered-on state. The value for system idle power is displayed in both watts and BTU/h units.
System Potential
Power
System Input
Current Reading
Displays the estimated power consumption of the chassis when it is operating at maximum power. The maximum power consumption is defined as the state of the chassis while it is ON and all modules are consuming maximum power. This is an estimated value derived from historical aggregate power consumption of the system configuration and not a measured value.
It is computed as the cumulative power allocated to chassis infrastructure components (I/O modules, fans, iKVM, iDRAC controllers and the front panel LCD) and the maximum power requirement of all servers that have been allocated power and are in the powered-on state. The value for system potential power is displayed in both watts and BTU/h units.
Displays the total input current draw of the chassis based on the sum of the input current draw of each of the individual
PSU modules in the chassis. The value for system input current reading is displayed in Amps.
Power Management 313
Table 9-9. Real-Time Energy Statistics Status
Item
System Energy
Consumption
System Energy
Consumption Start
Time
System Energy
Consumption
Timestamp
Description
Displays the current cumulative energy consumption for all modules in the chassis measured from the input side of the power supplies. The value is displayed in KWh and it is a cumulative value.
Displays the date and time recorded when the system energy consumption value was last cleared, and the new measurement cycle began. The timestamp is displayed in the format hh:mm:ss MM/DD/YYYY , where hh is hours (0-24), mm is minutes (00-60), ss is seconds (00-60), MM is the month (1-12), DD is the day (1-31), and YYYY is the year.
This value is reset with the Reset Energy Statistics button, but persists through a CMC reset or fail over operation.
Displays the date and time when the system energy consumption was calculated for display. The timestamp is displayed in the format hh:mm:ss MM/DD/YYYY , where hh is hours (0-24), mm is minutes (00-60), ss is seconds (00-60),
MM is the month (1-12), DD is the day (1-31), and YYYY is the year.
Table 9-10. System Power Status
Item Description
Overall Power Health Indicates the health status of the chassis’ power subsystem.:
• Green Check Icon for OK
• Yellow Exclamation Icon for Non-Critical
• Red X Icon for Critical
System Power Status Displays the power status ( On , Off , Powering On , Powering
Off ) of the chassis.
Redundancy Displays the redundancy status. Valid values are:
No — PSUs are not redundant
Yes — full redundancy in effect
314 Power Management
Table 9-11. Server Modules
Item
Slot
Name
Present
Actual (AC)
Cumulative
Power Start
Time
Peak
Consumption
Time Stamp
Description
Displays the location of the server module. The Slot is a sequential number (1–16) that identifies the server module by its location within the chassis.
Displays the server name. The server name can be redefined by the user.
Displays whether the server is present in the slot ( Yes or No ).
If this field displays Extension of # (where the # is 1-8), then number that follows it is the main slot of a multi-slot server.
Real-time measurement of the actual power consumption of the server. The measurement is displayed in watts AC.
Real-time measurement of the cumulative power that the server has consumed since the time displayed in the Start Time field.
The measurement is presented in KiloWatt Hour (kWh) units.
Displays the peak power that the server consumed at one time. The time when the peak power consumption occurred is recorded in the
Time Stamp field. The measurement is displayed in watts.
Viewing Power Budget Status
CMC provides power status overviews of the power subsystem on the Power
Budget Status page.
Using the Web Interface
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
1 Log in to the CMC Web interface .
2 Select Chassis Overview in the system tree.
3 Click Power ï‚® Budget Status .
The Power Budget Status page displays.
Power Management 315
Table 9-12 through Table 9-15 describe the information displayed on the
Power Budget Status page.
See "Configuring Power Budget and Redundancy" on page 320 for
information about configuring the settings for this information.
Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type: racadm getpbinfo
For more information about getpbinfo , including output details, see the getpbinfo command section in the Command Line Reference Guide for iDRAC6 and CMC.
Table 9-12. System Power Policy Configuration
Item
System Input
Power Cap
Description
Displays the user configured maximum power consumption limit for the entire system (chassis, CMC, servers, I/O modules, power supply units, iKVM, and fans). CMC enforces this limit via reduced server power allocations, or by powering off lower priority server modules. The value for system input power cap is displayed in watts, BTU/h and percent units.
If the chassis power consumption exceeds the System Input Power
Cap , then the performance of lower priority servers is reduced until total power consumption falls below the cap.
In cases where the servers are set to the same priority, then the selection of the server for power reduction, or power-off action, is based on the server slot number order. For example, the server in slot 1 is selected first and the server in slot 16 is selected last.
316 Power Management
Table 9-12. System Power Policy Configuration (continued)
Item
Redundancy
Policy
Description
Displays the current redundancy configuration: AC Redundancy ,
Power Supply Redundancy , and No Redundancy .
AC Redundancy — Power input is load-balanced across all PSUs.
Half of them should be cabled to one AC grid and the other half should be cabled to another grid. When the system is running optimally in AC Redundancy mode, power is load-balanced across all active supplies. In case of a grid failure, the PSUs on the functioning AC grid take over without interruption.
Power Supply Redundancy — The capacity of the highest-rated
PSU in the chassis is held in reserve, ensuring that a failure of any one PSU does not cause the server modules or chassis to power down.
Power Supply Redundancy may not use all six PSUs; it uses sufficient PSUs to assure that on the failure of any one the remaining can continue to supply power to the chassis. The other
PSUs may be placed in Standby mode if DPSE is enabled.
No Redundancy — The power from all active PSUs are sufficient to power the entire chassis, including the chassis, servers, I/O modules, iKVM, and CMC. The remaining PSUs may be placed in standby mode if DPSE is enabled.
CAUTION: The No Redundancy mode uses only the minimum required number of PSUs at a time, with no backup. Failure of one of the PSUs in use could cause the server modules to lose power and data.
Dynamic Power
Supply
Engagement
Displays whether Dynamic Power Supply Engagement is enabled or disabled. Enabling this feature allows CMC to put under-utilized PSUs into standby mode based on the redundancy policy that is set and the power requirements of the system. Putting under-utilized PSUs into standby mode increases the utilization, and efficiency, of the online PSUs, saving power.
Power Management 317
Table 9-13. Power Budgeting
Item Description
System Input
Max Power
Capacity
Input
Redundancy
Reserve
Maximum input power that the available power supplies can supply to the system (in watts).
Displays the amount of redundant power (in watts) in reserve that can be utilized in the event of an AC grid or power supply unit
(PSU) failure.
When the chassis is configured to operate in AC Redundancy mode, the Input Redundancy Reserve is the amount of reserve power that can be utilized in the event of an AC grid failure.
When the chassis is configured to operate in Power Supply
Redundancy mode, the Input Redundancy Reserve is the amount of reserve power that can be utilized in the event of a PSU failure.
Displays (in watts) the cumulative input power that CMC allocates to servers based on their configuration.
Input Power
Allocated to
Servers
Input Power
Allocated to
Chassis
Infrastructure
Displays (in watts) the cumulative input power that CMC allocates to the chassis infrastructure (Fans, IO modules, iKVM, CMC,
Standby CMC and iDRAC on servers).
Total Input
Power Available for Allocation
Displays the total chassis power, in watts, still available for allocation.
Standby Input
Power Capacity
Displays the amount of standby input power (in watts) that is available in the event of a Power Supply fault or Power Supply removal from the system. This field may show readings when the system has multiple power supplies and the Dynamic Power Supply
Engagement is enabled.
NOTE: It is possible to see a PSU in standby mode but not contribute to the Standby Input Power Capacity value. In this case, the watts from this PSU are contributing to the Total Input Power Available for
Allocation value.
318 Power Management
Table 9-14. Server Modules
Item
Slot
Name
Type
Priority
Power State
Budget
Allocation -
Actual
Description
Displays the location of the server module. The Slot is a sequential number (1–16) that identifies the server module by its location within the chassis.
Displays the server name. The server name is defined by the user.
Displays the type of the server.
Displays the priority level allotted to the server slot in the chassis for power budgeting. CMC uses this value in its calculations when power must be reduced or reallocated based on user-defined power limits or power supply or power grid failures.
Priority levels : 1 (highest) through 9 (lowest)
Default : 1
NOTE: Server slot priority level is associated with the server slot—not with the server inserted into the slot. If you move a server to a different slot in the chassis or to a different chassis, the priority previously associated with new slot determines the priority of the relocated server.
Displays the power status of the server:
• N/A: CMC has not determined the power state of the server.
• Off: Either the server or chassis is off.
• On: Both chassis and server are on.
• Powering On : Temporary state between Off and On. When the powering on cycle completes, the Power State changes to On.
• Powering Off: Temporary state between On and Off. When the powering off cycle completes, the Power State changes to Off.
Displays the power budget allocation for the server module.
• Actual: Current power budget allocation for each server.
Power Management 319
Table 9-15. Chassis Power Supplies
Item Description
Name
Power State
Displays the name of the PSU in the format PSn , where n , is the
PSU number.
Displays the power state of the PSU — Initializing , Online , Stand
By , In Diagnostics , Failed , Unknown , or Absent (missing).
Input Volts Displays the present input voltage of the power supply.
Input Current Displays the present input current of the power supply.
Output Rated
Power
Displays the maximum output power rating of the power supply.
Configuring Power Budget and Redundancy
CMC’s power management service optimizes power consumption for the entire chassis (the chassis, servers, IOMs, iKVM, CMC, and PSUs) and re-allocates power to different modules based on the demand.
Using the Web Interface
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
1 Log in to the CMC Web interface .
2 Select Chassis Overview in the system tree.
3 Click Power ï‚® Configuration .
The Budget/Redundancy Configuration page displays.
4
Set any or all of the properties described in Table 9-16 according
to your needs.
5 Click Apply to save your changes.
To refresh the content on the Budget/Redundancy Configuration page, click Refresh . To print the contents, click Print.
320 Power Management
Table 9-16. Configurable Power Budget/Redundancy Properties
Item
System Input Power
Cap
Description
System Input Power Cap is the maximum AC power that the system is allowed to allocate to servers and chassis infrastructure. It can be configured by the user to any value that exceeds the minimum power needed for servers that are powered on and the chassis infrastructure; configuring a value that falls below the minimum power needed for servers and the chassis infrastructure fails.
(
The power allocated to Servers and Chassis Infrastructure can be found in the User Interface on the Chassis Overview ï‚®
Power ï‚® Power Budget status page under Power Budgeting section or by using the CLI RACADM utility command racadm getpbinfo ).
Users can power off one or more server(s) to lower the current power allocation, and re-attempt setting a lower value for
System Input Power Cap (if desired) or simply configure the cap prior to powering on the servers.
To change this setting, it is possible to enter a value in any of the units. The interface ensures that the unit field that was last changed will be the value that is submitted when those changes are applied.
NOTE: See the Datacenter Capacity Planner (DCCP) tool at www.dell.com/calc for capacity planning.
NOTE: When value changes are specified in watts, the submitted value exactly reflects what is actually applied.
However, when the changes are submitted in either of the
BTU/h or percent units, the submitted value may not exactly reflect what is actually applied. This is because these units are converted to watts and then applied; and the conversion is susceptible to some rounding error.
Power Management 321
322
Table 9-16. Configurable Power Budget/Redundancy Properties (continued)
Item Description
Redundancy Policy This option allows you to select one the following options:
• No Redundancy : Power from the power supplies is used to power the entire chassis, including the chassis, servers, I/O modules, iKVM, and CMC. No power supplies must be kept in reserve.
NOTE: The No Redundancy mode uses only the minimum required number of power supplies at a time. If the minimum number of PSUs are installed, then there is no backup available.
Failure of one of the three power supplies being used could cause the servers to lose power and/or data. If more than the minimum required number of PSUs are present, then the additional PSUs may be placed in Standby mode for improving power efficiency if DPSE is enabled.
• Power Supply Redundancy : The capacity of the highest-rated power supply in the chassis is kept in reserve, ensuring that a failure of any one power supply does not cause the server modules or chassis to power down (hot spare).
Power Supply Redundancy mode may not utilize all installed power supplies. Any additional power supplies, if present, may be placed in Standby mode for improving power efficiency, when DPSE is enabled. Power Supply
Redundancy mode prevents server modules from powering up if the power consumption of the chassis exceeds the rated power. Failure of two power supplies may cause some or all server modules in the chassis to power down. Server module performance is not degraded in this mode.
• AC Redundancy : This mode divides half the PSUs into two power grids (for example, PSUs 1-3 make up power grid 1 and PSUs 4-6 make up power grid 2). Failure of a PSU or loss of AC power to one grid reports the redundancy status as lost.
Server Performance
Over Power
Redundancy
This option favors server performance and server powerup, over maintaining power redundancy. For more information
about this feature, see "Server Performance Over Power
Power Management
Table 9-16. Configurable Power Budget/Redundancy Properties (continued)
Item
Enable Dynamic
Power Supply
Engagement
Disable Chassis
Power Button
Allow 110 VAC
Operation
Max Conservation
Mode
Description
On selection, enables dynamic power management.
In Dynamic Engagement mode, the power supplies are turned ON (online) or OFF (standby) based on power consumption, optimizing the energy consumption of the entire chassis.
For example, your power budget is 5000 watts, your redundancy policy is set to AC redundancy mode, and you have six power supply units. CMC determines that four of the power supply units can manage the AC redundancy while the other two remain in standby mode. If an additional
2000W of power is needed for newly installed servers or power efficiency of the existing system configuration is required to be improved, then the two standby power supply units are engaged.
On selection, disables the chassis power button. If the check box is selected and you attempt to change the power state of the chassis by pressing the chassis power button, the action is ignored.
On selection, permits normal operation if any power supply units are connected to 110V AC input. For more information
see "110V PSUs Operation" on page 300.
On selection, immediately enters the maximum power
conservation mode. For more information see "Power
Conservation and Max Conservation Mode" on page 299.
Using RACADM
To enable and set the redundancy policy:
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
1 Open a serial/Telnet/SSH text console to CMC and log in.
2 Set properties as needed:
• To select a redundancy policy, type: racadm config -g cfgChassisPower -o cfgChassisRedundancyPolicy < value >
Power Management 323
where < value > is 0 (No Redundancy), 1 (AC Redundancy), 2
(Power Supply Redundancy). The default is 0.
For example, the following command: racadm config -g cfgChassisPower -o cfgChassisRedundancyPolicy 1 sets the redundancy policy to 1.
• To enable or disable dynamic PSU engagement, type: racadm config -g cfgChassisPower -o cfgChassisDynamicPSUEngagementEnable < value > where < value > is 0 (disable), 1 (enable). The default is 0.
For example, the following command: racadm config -g cfgChassisPower -o cfgChassisDynamicPSUEngagementEnable 0 disables dynamic PSU engagement.
For information about RACADM commands for chassis power, see the config , getconfig , getpbinfo , and cfgChassisPower sections in the Command
Line Reference Guide for iDRAC6 and CMC .
Assigning Priority Levels to Servers
Server priority levels determine which servers the CMC draws power from when additional power is required.
NOTE: The priority you assign to a server is linked to its slot and not to the server itself. If you move the server to a new slot, you must reconfigure the priority for the new slot location.
NOTE: To perform power management actions, you must have Chassis
Configuration Administrator privilege.
324 Power Management
Using the Web Interface
1 Log in to the CMC Web interface.
2 Select Servers Overview in the system tree. The Servers Status page appears.
3 Click Power ï‚® Server Priority .
The Server Priority page appears, listing all of the servers in your chassis.
4 Select a priority level (1–9, with 1 holding the highest priority) for one, multiple, or all servers. The default value is 1. You can assign the same priority level to multiple servers.
5 Click Apply to save your changes.
Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type: racadm config -g cfgServerInfo -o cfgServerPriority -i
< slot number > < priority level >
Where < slot number > (1–16) refers to the location of the server, and
< priority level > is a value between 1–9.
For example, the following command: racadm config -g cfgServerInfo -o cfgServerPriority -i
5 1 sets the priority level to 1 for the server in slot 5.
Setting the Power Budget
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
Using the Web Interface
1 Log in to the CMC Web interface.
2 Click Chassis Overview in the system tree. The Chassis Health page appears.
3 Click the Power tab.
The Power Consumption Status page appears.
Power Management 325
4 Click the Configuration subtab.
The Budget/Redundancy Configuration page appears.
5 Type a budget value of up to 11637 watts in the System Input Power Cap text field.
NOTE: The power budget is limited to a maximum of which ever set of three
PSUs that is the weakest.. If you attempt to set an AC power budget value that exceeds this value, CMC displays a failure message.
NOTE: When value changes are specified in watts, the submitted value will exactly reflect what is actually applied. However, when the changes are submitted in either of the BTU/h or percent units, the submitted value may not exactly reflect what is actually applied. This is because these units are converted to watts and then applied; and the conversion is susceptible to some rounding error.
6 Click Apply to save your changes.
Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type: racadm config -g cfgChassisPower -o cfgChassisPowerCap < value > where <value> is a number between 2715–11637 representing the maximum power limit in watts. The default is 11637.
For example, the following command: racadm config -g cfgChassisPower -o cfgChassisPowerCap 5400 sets the maximum power budget to 5400 watts.
NOTE: The power budget is limited to 11637 Watts. If you attempt to set an AC power budget value that exceeds the power capacity of your chassis, CMC displays a failure message.
326 Power Management
Server Power Reduction to Maintain Power Budget
CMC reduces power allocations of lower priority servers when additional power is needed to maintain the system power consumption within the user-configured System Input Power Cap . For example, when a new server is engaged, CMC may decrease power to low priority servers to allow more power for the new server. If the amount of power is still insufficient after reducing power allocations of the lower priority servers, CMC lowers the performance of servers until sufficient power is freed to power the new server.
CMC reduces server power allocation in two cases:
• Overall power consumption exceeds the configurable System Input Power
Cap
(see "Setting the Power Budget" on page 325.)
• A power failure occurs in a non-redundant configuration.
For information about assigning priority levels to servers, see "Executing
Power Control Operations on the Chassis" on page 327.
Executing Power Control Operations on the Chassis
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
NOTE: Power control operations affect the entire chassis. For power control
operations on an IOM, see "Executing Power Control Operations on an IOM" on
page 329. For power control operations on servers, see "Executing Power Control
Operations on a Server" on page 330.
CMC enables you to remotely perform several power management actions, such as an orderly shutdown, on the entire chassis (chassis, servers, IOMs, iKVM, and PSUs).
Using the Web Interface
1 Log in to the CMC Web interface.
2 Select Chassis Overview in the system tree.
3 Click the Power tab.
The Power Consumption Status page displays.
4 Click the Control subtab.
The Chassis Power Control page displays.
Power Management 327
5 Click the corresponding radio buttons to select one of the following Power
Control Operations :
• Power On System — Turns on the chassis power (the equivalent of pressing the power button when the chassis power is OFF ).
This option is disabled if the chassis is already powered ON .
NOTE: This action powers on the chassis and other subsystems (iDRAC on the servers, IOMs, and iKVM). Servers do not power on.
• Power Off System — Turns off the chassis power. This option is disabled if the chassis is already powered OFF .
NOTE: This action powers off the chassis (chassis, servers, IOMs, iKVM, and power supplies). CMCs remain powered on, but in virtual standby state; a power supply unit and fans provide cooling for CMCs in this state.
The power supply also provides power to the fans that run at low speed.
• Power Cycle System (cold boot) — Powers off and then reboots the system (cold boot). This option is disabled if the chassis is already powered OFF .
NOTE: This action powers off and then reboots the entire chassis (chassis, servers which are configured to always power on, IOMs, iKVM, and power supplies).
• Reset CMC — Resets CMC without powering off (warm reboot).
(This option is disabled if CMC is already powered off).
NOTE: This action only resets CMC. No other components are affected.
• Non-Graceful Shutdown — This action forces a non-graceful power off of the entire chassis (chassis, servers, IOMs, iKVM, and power supplies). This does not attempt to cleanly shutdown the operating system of the servers prior to powering off.
6 Click Apply . A dialog box appears requesting confirmation.
7 Click OK to perform the power management action (for example, cause the system to reset).
328 Power Management
Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type: racadm chassisaction -m chassis < action > where <action > is powerup , powerdown , powercycle , nongraceshutdown or reset .
Executing Power Control Operations on an IOM
You can remotely execute a reset or power cycle on an individual IOM.
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
Using the Web Interface
1 Log in to the CMC Web interface.
2 Select I/O Modules Overview .
The I/O Modules Status page displays.
3 Click the Power tab.
The Power Control page displays.
4 Select the operation you want to execute ( reset or power cycle ) from the drop-down menu beside the IOM in the list.
5 Click Apply .
A dialog box appears requesting confirmation.
6 Click OK to perform the power management action (for example, cause the IOM to power cycle).
Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type: racadm chassisaction -m switch-< n > < action > where < n > is a number 1-6 and specifies the IOM (A1, A2, B1, B2, C1, C2), and < action > indicates the operation you want to execute: powercycle or reset .
Power Management 329
Executing Power Control Operations on a Server
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
CMC enables you to remotely perform several power management actions, for example, an orderly shutdown, on an individual server in the chassis.
Using the Web Interface
1 Log in to the CMC Web interface.
2 Expand Server Overview in the system tree, and then select the server on which you want to execute a power control operation. The Server Status page displays.
3 Click the Power tab.
The Server Power Management page displays.
4 Power Status displays the power status of the server (one of the following):
• N/A - CMC has not yet determined the power state of the server.
• Off - Either the server is off or the chassis is off.
• On - Both chassis and server are on.
• Powering On - Temporary state between Off and On. When the action completes successfully, the Power State is On .
• Powering Off - Temporary state between On and Off. When the action completes successfully, the Power State is Off .
5 Select one of the following Power Control Operations by clicking its radio button:
• Power On Server — Turns on the server power (equivalent to pressing the power button when the server power is off). This option is disabled if the server is already powered on.
• Power Off Server — Turns off the server power (equivalent to pressing the power button when the server power is on).
• Graceful Shutdown — Powers off and then reboots the server.
330 Power Management
• Reset Server (warm boot) — Reboots the server without powering off.
This option is disabled if the server is powered off.
• Power Cycle Server (cold boot) — Powers off and then reboots the server. This option is disabled if the server is powered off.
6 Click Apply . A dialog box appears requesting confirmation.
7 Click OK to perform the power management action (for example, cause the server to reset).
NOTE: All of the power control operations can be performed on multiple servers from the Servers ï‚® Power ï‚® Control page.
Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type: racadm serveraction -m < module > < action > where <module > specifies the server by its slot number (server-1 through server-16) in the chassis, and <action > indicates the operation you want to execute: powerup , powerdown , powercycle, graceshutdown , or hardreset .
110V Operation
Some models of power supplies (PSUs) are capable of operating both from
220V mains as well as 110V mains. 110V power may have limited capacity; hence when any 110V connection is detected, the chassis does not grant any additional server power requests until the user acknowledges 110V operation by changing that power configuration property. The user must verify that the
110V circuit in use can deliver the power required for the chassis configuration before the acknowledgement. After acknowledgement, the chassis grants all future appropriate server power requests and uses all available power supply capacity.
The user can reset the 110V acknowledgement at any time from the GUI or
RACADM after initial installation. Power supply entries are logged to the
SEL log when 110V power supplies are detected and when 110V supplies are removed. Entries are also logged to the SEL log when acknowledged and unacknowledged by the user.
Power Management 331
The overall power health is at least in Non-Critical state when the chassis is operating in 110V mode and the user has not acknowledged the 110V operation. The "Warning" icon is displayed on the GUI main page when in
Non-Critical state.
Mixed 110V and 220V operation is not supported. If CMC detects that both voltages are in use then one voltage is selected and those power supplies connected to the other voltage are powered off and marked as failed.
Troubleshooting
For power supply and power-related issue troubleshooting, see
"Troubleshooting and Recovery" on page 375.
332 Power Management
10
Using the iKVM Module
Overview
The local access KVM module for your Dell M1000e server chassis is called the Avocent Integrated KVM Switch Module, or iKVM. The iKVM is an analog keyboard, video, and mouse switch that plugs into your chassis. It is an optional, hot-pluggable module to the chassis that provides local keyboard, mouse, and video access to the servers in the chassis, and to the active CMC’s command line.
iKVM User Interface
The iKVM uses the On Screen Configuration and Reporting (OSCAR) graphical user interface, which is activated by a hot key. OSCAR allows you to select one of the servers or the Dell CMC command line you wish to access with the local keyboard, display, and mouse.
Only one iKVM session per chassis is allowed.
Security
The OSCAR user interface allows you to protect your system with a screen saver password. After a user-defined time, the screen saver mode engages, and access is prohibited until the appropriate password is entered to reactivate OSCAR.
Scanning
OSCAR allows you to select a list of servers, which are displayed in the order selected while OSCAR is in scan mode.
Using the iKVM Module 333
Server Identification
CMC assigns slots names for all servers in the chassis. Although you can assign names to the servers using the OSCAR interface from a tiered connection, CMC assigned names take precedence, and any new names you assign to servers using OSCAR is overwritten.
CMC identifies a slot by assigning it a unique name. To change slot names
using the CMC Web interface, see "Editing Slot Names." To change a slot
name using RACADM, see the setslotname section in the
Command Line
Reference Guide for iDRAC6 and CMC.
Video
The iKVM video connections support video display resolutions ranging from 640 x 480 at 60 Hz up to 1280 x 1024 at 60 Hz.
Plug and Play
The iKVM supports Display Data Channel (DDC) Plug and Play, which automates video monitor configuration, and is compliant with the VESA DDC2B standard.
FLASH Upgradable
You can update the iKVM firmware using the CMC Web interface or RACADM fwupdate
command. For more information, see "Managing iKVM From CMC" on page 351.
Physical Connection Interfaces
You can connect to a server or the CMC CLI console through the iKVM from the chassis front panel, an Analog Console Interface (ACI), and the chassis rear panel.
NOTE: The ports on the control panel on the front of the chassis are designed specifically for the iKVM, which is optional. If you do not have the iKVM, you cannot use the front control panel ports.
334 Using the iKVM Module
iKVM Connection Precedences
Only one iKVM connection is available at a time. The iKVM assigns an order of precedence to each type of connection so that when there are multiple connections, only one connection is available while others are disabled.
The order of precedence for iKVM connections is as follows:
1 Front panel
2 ACI
3 Rear Panel
For example, if you have iKVM connections in the front panel and ACI, the front panel connection remains active while the ACI connection is disabled. If you have ACI and rear connections, the ACI connection takes precedence.
Tiering Through the ACI Connection
The iKVM allows tiered connections with servers and the iKVM’s CMC command line console, either locally through a Remote Console Switch port or remotely through the Dell RCS software. The iKVM supports ACI connections from the following products:
• 180AS, 2160AS, 2161DS*, 2161DS-2, or 4161DS Dell Remote Console
Switches
• Avocent AutoView switching system
• Avocent DSR switching system
• Avocent AMX switching system
* Does not support the Dell CMC console connection.
NOTE: The iKVM also supports an ACI connection to the Dell 180ES and 2160ES, but the tiering is non-seamless. This connection requires a USB to PS2 SIP.
Using the iKVM Module 335
336
Using OSCAR
This section provides an overview of the OSCAR interface.
Navigation Basics
.
Table 10-1. OSCAR Keyboard and Mouse Navigation
Key or Key Sequence Result
• <Print Screen>-
<Print Screen>
• <Shift>-<Shift>
• <Alt>-<Alt>
• <Ctrl>-<Ctrl>
<F1>
<Esc>
Any of these key sequences can open OSCAR, depending on your Invoke OSCAR settings. You can enable two, three, or all of these key sequences by selecting boxes in the Invoke
OSCAR section of the Main dialog box, and then clicking
OK .
<Alt>
<Alt>+<X>
<Alt>+<O>
<Enter>
Single-click,
<Enter>
<Print Screen>,
<Backspace>
Opens the Help screen for the current dialog box.
Closes the current dialog box without saving changes and returns to the previous dialog box.
In the Main dialog box, <Esc> closes the OSCAR interface and returns to selected server.
In a message box, it closes the pop-up box and returns to the current dialog box.
Opens dialog boxes, selects or checks options, and executes actions when used in combination with underlined letters or other designated characters.
Closes the current dialog box and returns to the previous dialog box.
Selects the OK button, then returns to the previous dialog box.
Completes a switch operation in the Main dialog box and exits OSCAR.
In a text box, selects the text for editing and enables the left-arrow key and right-arrow keys to move the cursor.
Press <Enter> again to quit the edit mode.
Toggles back to previous selection if there were no other keystrokes.
Using the iKVM Module
Table 10-1. OSCAR Keyboard and Mouse Navigation (continued)
Key or Key Sequence Result
<Print Screen>,
<Alt>+<0>
<Print Screen>,
<Pause>
Immediately disconnects a user from a server; no server is selected. Status flag displays Free. (This action only applies to the =<0> on the keyboard and not the keypad.)
Immediately turns on screen saver mode and prevents access to that specific console, if it is password protected.
Up/Down Arrow keys Moves the cursor from line to line in lists.
Right/Left Arrow keys Moves the cursor within the columns when editing a text box.
<Home>/<End> Moves the cursor to the top (Home) or bottom (End) of a list.
<Delete> Deletes characters in a text box.
Number keys
<Caps Lock>
Type from the keyboard or keypad.
Disabled. To change case, use the <Shift> key.
Configuring OSCAR
Table 10-2. OSCAR Setup Menu Features
Feature
Menu
Security
Flag
Language
Broadcast
Scan
Purpose
Changes the server listing between numerically by slot or alphabetically by name.
• Sets a password to restrict access to servers.
• Enables a screen saver and set an inactivity time before the screen saver appears and set the screen save mode.
Changes display, timing, color, or location of the status flag.
Changes the language for all OSCAR screens.
Sets up to simultaneously control multiple servers through keyboard and mouse actions.
Sets up a custom scan pattern for up to 16 servers.
To access the Setup dialog box:
1 Press <Print Screen> to launch the OSCAR interface. The Main dialog box appears.
2 Click Setup . The Setup dialog box appears.
Using the iKVM Module 337
Changing the Display Behavior
Use the Menu dialog box to change the display order of servers and set a
Screen Delay Time for OSCAR.
To access the Menu dialog box:
1 Press <Print Screen> to launch OSCAR. The Main dialog box appears.
2 Click Setup and then Menu . The Menu dialog box appears.
To choose the default display order of servers in the Main dialog box:
1 Select Name to display servers alphabetically by name.
or
Select Slot to display servers numerically by slot number.
2 Click OK .
To assign one or more key sequences for OSCAR activation:
1 Select a key sequence from the Invoke OSCAR menu.
2 Click OK .
The default key to invoke OSCAR is <Print Screen>.
To set a Screen Delay Time for the OSCAR:
1 Enter the number of seconds (0 through 9) to delay display of OSCAR after you press <Print Screen>. Entering <0> launches OSCAR with no delay.
2 Click OK .
Setting a time to delay display of OSCAR allows you to complete a soft
switch. To perform a soft switch, see "Soft Switching" on page 342.
Controlling the Status Flag
The status flag displays on your desktop and shows the name of the selected server or the status of the selected slot. Use the Flag dialog box to configure the flag to display by server, or to change the flag color, opacity, display time, and location on the desktop.
338 Using the iKVM Module
Table 10-3. OSCAR Status Flags
Flag Description
Flag type by name
Flag indicating that the user has been disconnected from all systems
Flag indicating that Broadcast mode is enabled
To access the Flag dialog box:
1 Press <Print Screen>. The Main dialog box appears.
2 Click Setup and then Flag . The Flag dialog box appears.
To specify how the status flag displays:
1 Select Displayed to show the flag all the time or Displayed and Timed to display the flag for only five seconds after switching.
NOTE: If you select Timed by itself, the flag is not displayed.
2 Select a flag color from the Display Color section. Options are black, red, blue, and purple.
3 In Display Mode , select Opaque for a solid color flag or Transparent to see the desktop through the flag.
4 To position the status flag on the desktop: a b c
Click Set Position.
The Set Position Flag displays.
Left-click on the title bar and drag it to the desired location on the desktop.
Right-click to return to the Flag dialog box.
NOTE: Changes made to the flag position are not saved until you click OK in the
Flag dialog box.
5 Click OK to save settings.
To exit without saving changes, click .
Using the iKVM Module 339
Managing Servers With iKVM
The iKVM is an analog switch matrix supporting up to 16 servers. The iKVM switch uses the OSCAR user interface to select and configure your servers.
In addition, the iKVM includes a system input to establish a CMC command line console connection to CMC.
Peripherals Compatibility and Support
The iKVM is compatible with the following peripherals:
• Standard PC USB keyboards with QWERTY, QWERTZ, AZERTY, and Japanese 109 layouts.
• VGA monitors with DDC support.
• Standard USB pointing devices.
• Self-powered USB 1.1 hubs connected to the local USB port on the iKVM.
• Powered USB 2.0 hubs connected to the Dell M1000e chassis’ front panel console.
NOTE: You can use multiple keyboards and mice on the iKVM local USB port.
The iKVM aggregates the input signals. If there are simultaneous input signals from multiple USB keyboards or mice, it may have unpredictable results.
NOTE: The USB connections are solely for supported keyboard, mouse, and USB hubs. iKVM does not support data transmitted from other USB peripherals.
Viewing and Selecting Servers
Use the OSCAR Main dialog box to view, configure, and manage servers through the iKVM. You can view your servers by name or by slot. The slot number is the chassis slot number the server occupies. The Slot column indicates the slot number in which a server is installed.
NOTE: The Dell CMC command line occupies Slot 17. Selecting this slot displays the CMC command line, where you can execute RACADM commands or connect to the serial console of server or I/O modules.
NOTE: Server names and slot numbers are assigned by CMC.
340 Using the iKVM Module
To access the Main dialog box:
Press <Print Screen> to launch the OSCAR interface. The Main dialog box appears.
or
If a password has been assigned, the Password dialog box appears. Type your password and click OK . The Main dialog box appears.
For more information about setting a password, see "Setting Console
NOTE: There are four options for invoking OSCAR. You can enable one, multiple, or all of these key sequences by selecting boxes in the Invoke OSCAR section of the
Main dialog box and then clicking OK.
Viewing the Status of Your Servers
The status of the servers in your chassis is indicated in the right columns of the Main dialog box. The following table describe the status symbols.
Table 10-4. OSCAR Interface Status Symbols
Symbols Description
(Green dot.) Server is online.
(Red X.) Server is offline or absent from chassis.
(Yellow dot.) Server is not available.
(Green A or B.) Server is being accessed by the user channel indicated by the letter: A=rear panel, B=front panel.
Using the iKVM Module 341
Selecting Servers
Use the Main dialog box to select servers. When you select a server, the iKVM reconfigures the keyboard and mouse to the proper settings for that server.
• To select servers:
Double-click the server name or the slot number.
or
If the display order of your server list is by slot (that is, the Slot button is depressed), type the slot number and press <Enter>.
or
If the display order of your server list is by name (that is, the Name button is depressed), type the first few characters of the server name, establish it as unique, and press <Enter> twice.
• To select the previous server:
Press <Print Screen> and then <Backspace>. This key combination toggles between the previous and current connections.
• To disconnect the user from a server:
Press <Print Screen> to access OSCAR and then click Disconnect .
or
Press <Print Screen> and then <Alt><0>. This leaves you in a free state, with no server selected. The status flag on your desktop,
if active, displays Free. See "Controlling the Status Flag" on page 338.
Soft Switching
Soft switching is switching between servers using a hotkey sequence. You can soft switch to a server by pressing <Print Screen> and then typing the first few characters of its name or number. If you previously set a delay time
(the number of seconds before the Main dialog box is displayed after <Print
Screen> is pressed) and you press the key sequences before that time has elapsed, the OSCAR interface does not display.
342 Using the iKVM Module
To configure OSCAR for soft switching:
1 Press <Print Screen> to launch the OSCAR interface. The Main dialog box appears.
2 Click Setup and then Menu . The Menu dialog box appears.
3 Select Name or Slot for the Display/Sort Key.
4 Type the desired delay time in seconds in the Screen Delay Time field.
5 Click OK .
To soft switch to a server:
• To select a server, press <Print Screen>.
If the display order of your server list is by slot as per your selection in step 3 (that is, the Slot button is depressed), type the slot number and press <Enter>.
or
If the display order of your server list is by name as per your selection in step 3(that is, the Name button is depressed), type the first few characters of the name of the server to establish it as unique and press <Enter>.
• To switch back to the previous server, press <Print Screen> then
<Backspace>.
Video Connections
The iKVM has video connections on the front and rear panels of the chassis.
The front panel connection signals take precedence over that of the rear panel. When a monitor is connected to the front panel, the video connection does not pass through to the rear panel, and an OSCAR message displays stating that the rear panel KVM and ACI connections are disabled. If the monitor is disabled (that is, removed from the front panel or disabled by a
CMC command), the ACI connection becomes active while the rear panel
KVM remains disabled. (For information about order of connection
precedence, see "iKVM Connection Precedences.")
For information about enabling or disabling the front panel connection, see
"Enabling or Disabling the Front Panel."
Using the iKVM Module 343
Preemption Warning
Normally, a user connected to a server console through the iKVM and another user connected to the same server console through the iDRAC GUI console redirection feature both have access to the console and are able to type simultaneously.
To prevent this scenario, the remote user, before starting the iDRAC GUI console redirection, can disable the local console in the iDRAC Web interface. The local iKVM user sees an OSCAR message that the connection is preempted in a specified amount of time. The local user should finish work before the iKVM connection to the server is terminated.
There is no preemption feature available to the iKVM user.
NOTE: If a remote iDRAC user has disabled the local video for a specific server, that server's video, keyboard and mouse is unavailable to the iKVM. The server state is marked with a yellow dot in the OSCAR menu to indicate that it is locked or
unavailable for local use (see "Viewing the Status of Your Servers").
Setting Console Security
OSCAR enables you to configure security settings on your iKVM console.
You can establish a screen saver mode that engages after your console remains unused for a specified delay time. Once engaged, your console remains locked until you press any key or move the mouse. Enter the screen saver password to continue.
Use the Security dialog box to lock your console with password protection, set or change your password, or enable the screen saver.
NOTE: If the iKVM password is lost or forgotten, you can reset it to the iKVM
factory default using the CMC Web interface or RACADM. See "Clearing a Lost or
Accessing the Security Dialog Box
1 Press <Print Screen>. The Main dialog box appears.
2 Click Setup and the Security . The Security dialog box appears.
344 Using the iKVM Module
Setting or Changing the Password
1 Single-click and press <Enter> or double-click in the New field.
2 Type the new password in the New field and then press <Enter>.
Passwords are case sensitive and require 5–12 characters. They must include at least one letter and one number. Legal characters are: A–Z, a–z,
0–9, space, and hyphen.
3 In the Repeat field, type the password again, and then press <Enter>.
4 Click OK if you only want to change your password, and then close the dialog box.
Password-protecting Your Console
1 Set your password as described in the previous procedure.
2 Select the Enable Screen Saver box.
3 Type the number of minutes of Inactivity Time (from 1 through 99) to delay password protection and screen saver activation.
4 For Mode : If your monitor is ENERGY STAR compliant, select Energy ; otherwise select Screen .
NOTE: If the mode is set to Energy, the appliance puts the monitor into sleep mode. This is normally indicated by the monitor powering off and the amber light replacing the green power LED. If the mode is set to Screen, the OSCAR flag bounces around the screen for the duration of the test. Before the test starts, a warning popup box displays the following message: "Energy mode may damage a monitor that is not ENERGY STAR compliant. However, once started, the test can be quit immediately via mouse or keyboard interaction."
CAUTION: Monitor damage may result from the use of Energy mode with monitors not compliant with Energy Star.
5 Optional: To activate the screen saver test, click Test . The Screen Saver
Test dialog box displays. Click OK to start the test.
The test takes 10 seconds. When it concludes, you are returned to the
Security dialog box.
Using the iKVM Module 345
Logging In
1 Press <Print Screen> to launch OSCAR. The Password dialog box appears.
2 Type your password and then click OK . The Main dialog box appears.
Setting Automatic Logout
You can set OSCAR to automatically log out of a server after a period of inactivity.
1 In the Main dialog box, click Setup and then Security .
2 In the Inactivity Time field, enter the length of time you want to stay connected to a server before it automatically disconnects you.
3 Click OK .
Removing Password Protection From Your Console
1 From the Main dialog box, click Setup and then Security .
2 In the Security dialog box, single-click and press <Enter>, or double-click in the New field.
3 Leaving the New field empty, press <Enter>.
4 Single-click and press <Enter>, or double-click in the Repeat field.
5 Leaving the Repeat field empty, press <Enter>.
6 Click OK if you only want to eliminate your password.
Enabling Screen Saver Mode With No Password Protection
NOTE: If your console is password protected, you must first remove password protection. Follow the steps in the previous procedure before following the steps below.
1 Select Enable Screen Saver .
2 Type the number of minutes (1 through 99) that you want to delay activation of the screen saver.
346 Using the iKVM Module
3 Select Energy if your monitor is ENERGY STAR compliant; otherwise select Screen .
CAUTION: Monitor damage may result from the use of Energy mode with monitors not compliant with Energy Star.
4 Optional: To activate the screen saver test, click Test . The Screen Saver
Test dialog box displays. Click OK to start the test.
The test takes 10 seconds. When it concludes, you are returned to the
Security dialog box.
NOTE: Enabling screen saver mode disconnects the user from a server; no server is selected. The status flag displays Free.
Exiting Screen Saver Mode
To exit screen saver mode and return to the Main dialog box, press any key or move your mouse.
To turn off the screen saver:
1 In the Security dialog box, clear the Enable Screen Saver box.
2 Click OK .
To immediately turn on the screen saver, press <Print Screen>, then press <Pause>.
Clearing a Lost or Forgotten Password
When the iKVM password is lost or forgotten, you can reset it to the iKVM factory default, and then change the password. You can reset the password using either the CMC Web interface or RACADM.
To reset a lost or forgotten iKVM password using the CMC Web interface:
1 Log in to the CMC Web interface.
2 Select iKVM from the Chassis submenu.
3 Click the Setup tab. The iKVM Configuration page displays.
4 Click Restore Default Values .
You can then change the password from the default using OSCAR.
See "Setting or Changing the Password."
Using the iKVM Module 347
To reset a lost or forgotten password using RACADM, open a serial/Telnet/SSH text console to CMC, log in, and type: racadm racresetcfg -m kvm
NOTE: Using the racresetcfg command resets the Front Panel Enable and Dell
CMC Console Enable settings, if they are different from the default values.
For more information about the racresetcfg subcommand, see the racresetcfg section in the Command Line Reference Guide for iDRAC6 and CMC .
Changing the Language
Use the Language dialog box to change the OSCAR text to display in any of the supported languages. The text immediately changes to the selected language on all of the OSCAR screens.
To change the OSCAR language:
1 Press <Print Screen>. The Main dialog box appears.
2 Click Setup and then Language . The Language dialog box appears.
3 Click the radio button for the desired language, and then click OK .
Displaying Version Information
Use the Version dialog box to display the iKVM firmware and hardware versions, and to identify the language and keyboard configuration.
To display version information:
1 Press <Print Screen>. The Main dialog box appears.
2 Click Command s and then Display Versions . The Version dialog box appears.
The top half of the Version dialog box lists the subsystem versions in the appliance.
3 Click or press <Esc> to close the Version dialog box.
Scanning Your System
In scan mode, the iKVM automatically scans from slot to slot (server to server). You can scan up to 16 servers by specifying which servers you want to scan and the number of seconds that each server is displayed.
348 Using the iKVM Module
To add servers to the scan list:
1 Press <Print Screen>. The Main dialog box appears.
2 Click Setup and then Scan . The Scan dialog box appears, listing of all servers in the chassis.
3 Select the box next to the servers you wish to scan.
or
Double-click the server name or slot.
or
Press <Alt > and the number of the server you wish to scan. You can select up to 16 servers.
4 In the Time field, enter the number of seconds (3 through 99) that you want iKVM to wait before the scan moves to the next server in the sequence.
5 Click the Add/Remove button, and then click OK .
To remove a server from the Scan list:
1 In the Scan dialog box, select the box next to the server to be removed.
or
Double-click the server name or slot.
or
Click the Clear button to remove all servers from the Scan list.
2 Click the Add/Remove button, and then click OK .
To start Scan mode:
1 Press <Print Screen>. The Main dialog box appears.
2 Click Commands . The Command dialog box appears.
3 Select the Scan Enable box.
4 Click OK . A message appears indicating that the mouse and keyboard have been reset.
5 Click to close the message box.
Using the iKVM Module 349
To cancel scan mode:
1 If OSCAR is open and the Main dialog box is displayed, select a server in the list.
or
If OSCAR is not open, move the mouse or press any key on the keyboard.
Scanning stops at the currently selected server.
or
Press <Print Screen>. The Main dialog box appears; select a server in the list.
2 Click the Commands button. The Commands dialog box appears.
3 Clear the Scan Enable box.
Broadcasting to Servers
You can simultaneously control more than one server in the system to ensure that all selected servers receive identical input. You can choose to broadcast keystrokes and/or mouse movements independently.
NOTE: You can broadcast up to 16 servers at a time.
To broadcast to servers:
1 Press <Print Screen>. The Main dialog box appears.
2 Click Setup and then Broadcast . The Broadcast dialog box appears.
NOTE: Broadcasting keystrokes: When using keystrokes, the keyboard state must be identical for all servers receiving a broadcast for the keystrokes to be interpreted identically. Specifically, the <Caps Lock> and <Num Lock> modes must be the same on all keyboards. While the iKVM attempts to send keystrokes to the selected servers simultaneously, some servers may inhibit and thereby delay the transmission.
NOTE: Broadcasting mouse movements: For the mouse to work accurately, all servers must have identical mouse drivers, desktops (such as identically placed icons), and video resolutions. The mouse also must be in exactly the same place on all screens. Because these conditions are extremely difficult to achieve, broadcasting mouse movements to multiple servers may have unpredictable results.
350 Using the iKVM Module
3 Enable mouse and/or keyboard for the servers that are to receive the broadcast commands by selecting the boxes.
or
Press the up or down arrow keys to move the cursor to a target server.
Then press <Alt><K> to select the keyboard box and/or <Alt><M> to select the mouse box. Repeat for additional servers.
4 Click OK to save the settings and return to the Setup dialog box. Click or press <Escape> to return to the Main dialog box.
5 Click Commands . The Commands dialog box appears.
6 Click the Broadcast Enable box to activate broadcasting. The Broadcast
Warning dialog box appears.
7 Click O K to enable the broadcast.
To cancel and return to the Commands dialog box, click or press
<Esc>.
8 If broadcasting is enabled, type the information and/or perform the mouse movements you want to broadcast from the management station.
Only servers in the list are accessible.
To turn broadcasting off:
From the Commands dialog box, clear the Broadcast Enable box.
Managing iKVM From CMC
Enabling or Disabling the Front Panel
To enable or disable access to the iKVM from the front panel using
RACADM, open a serial/Telnet/SSH text console to CMC, log in, and type: racadm config -g cfgKVMInfo -o cfgKVMFrontPanelEnable
< value > where < value > is 1 (enable) or 0 (disable).
For more information about the config subcommand, see the config command section in the Command Line Reference Guide for iDRAC6 and
CMC .
Using the iKVM Module 351
352
To enable or disable access to the iKVM from the front panel using the Web interface:
1 Log in to the CMC Web interface.
2 Select iKVM in the system tree. The iKVM Status page displays.
3 Click the Setup tab. The iKVM Configuration page displays.
4 To enable, select the Front Panel USB/Video Enabled check box.
To disable, clear the Front Panel USB/Video Enabled check box.
5 Click Apply to save the setting.
Enabling the Dell CMC Console Through iKVM
To enable the iKVM to access the Dell CMC console using RACADM, open a serial/Telnet/SSH text console to CMC, log in, and type: racadm config -g cfgKVMInfo -o cfgKVMAccessToCMCEnable 1
To enable the Dell CMC console using the Web interface:
1 Log in to the CMC Web interface.
2 Select iKVM in the system tree. The iKVM Status page displays.
3 Click the Setup tab. The iKVM Configuration page displays.
4 Select the Allow access to CMC CLI from iKVM check box.
5 Click Apply to save the setting.
Viewing the iKVM Status and Properties
The local access KVM module for your Dell M1000e server chassis is called the Avocent Integrated KVM Switch Module, or iKVM. The health status of the iKVM associated with the chassis can be viewed on the Chassis Properties
Health page under the Chassis Graphics section.
To view health status for the iKVM using Chassis Graphics :
1 Log in to the CMC Web interface.
2 The Chassis Status page is displayed. The right section of Chassis
Graphics depicts the rear view of the chassis and contains the health status of the iKVM. iKVM health status is indicated by the color of the iKVM subgraphic:
Using the iKVM Module
• Green - iKVM is present, powered on and communicating with the CMC; there is no indication of an adverse condition.
• Amber - iKVM is present, but may or may not be powered on, or may or may not be communicating with CMC; an adverse condition may exist.
• Gray - iKVM is present and not powered on. It is not communicating with CMC and there is no indication of an adverse condition.
3 Use the cursor to hover over the iKVM subgraphic and a corresponding text hint or screen tip is displayed. The text hint provides additional information on that iKVM.
4 The iKVM subgraphic is hyperlinked to the corresponding CMC GUI page to provide immediate navigation to the iKVM Status page.
For more information about iKVM, see "Using the iKVM Module."
To view the status of the iKVM using the iKVM Status page:
1 Log in to the CMC Web interface.
2 Select iKVM in the system tree. The iKVM Status page displays.
Table 10-5. iKVM Status Information
Item
Presence
Power State
Name
Manufacturer
Part Number
Firmware Version
Hardware Version
Front Panel
Connected
Description
Displays whether the iKVM module is Present or Absent .
Displays the power status of the iKVM: On , Off , or N/A (Absent).
Displays the product name of the iKVM.
Displays in the manufacturer of the iKVM.
Displays the part number for the iKVM. The part number is a unique identifier provided by the vendor.
Displays the firmware version of the iKVM.
Displays the hardware version of the iKVM.
Displays whether the monitor is connected to the front panel
VGA connector ( Yes or No ). This information is provided to
CMC so it can determine whether a local user has front-panel access to the chassis.
Using the iKVM Module 353
354
Table 10-5. iKVM Status Information (continued)
Item Description
Rear Panel
Connected
Tiering Port
Connected
Front Panel
USB/Video Enabled (
Indicates whether the monitor is connected to the rear panel
VGA connector ( Yes or No ). This information is provided to
CMC so it can determine whether a local user has rear-panel access to the chassis.
The iKVM supports seamless tiering with external KVM appliances from Dell and Avocent using built-in hardware.
When the iKVM is tiered, the servers in the chassis can be accessed through the screen display of the external KVM switch from which the iKVM is tiered.
Displays whether the front panel VGA connector is enabled
Yes or No ).
Allow access to CMC from iKVM
Indicates whether the CMC command console through iKVM is enabled ( Yes or No ).
Updating the iKVM Firmware
You can update the iKVM firmware using the CMC Web interface or
RACADM.
To update the iKVM firmware using the CMC Web interface:
1 Log in to the CMC Web interface.
2 Click Chassis in the system tree.
3 Click the Update tab. The Updatable Components page displays.
4 Click the iKVM name. The Firmware Update page appears.
5 In the Firmware Image field, enter the path to the firmware image file on your management station or shared network, or click Browse to navigate to the file location.
NOTE: The default iKVM firmware image name is ikvm.bin; however, the iKVM firmware image name can be changed by the user.
6 Click Begin Firmware Update . A dialog box prompts you to confirm the action.
7 Click Yes to continue. The Firmware Update Progress section provides firmware update status information. A status indicator displays on the page while the image file uploads. File transfer time can vary greatly
Using the iKVM Module
based on connection speed. When the internal update process begins, the page automatically refreshes and the Firmware update timer displays.
Additional instructions to follow:
• Do not use the Refresh button or navigate to another page during the file transfer.
• To cancel the process, click Cancel File Transfer and Update - this option is available only during file transfer.
• Update status displays in the Update State field; this field is automatically updated during the file transfer process. Certain older browsers do not support these automatic updates. To manually refresh the Update State field, click Refresh .
NOTE: The update may take up to one minute for the iKVM.
When the update is complete, iKVM resets and the new firmware is updated and displayed on the Updatable Components page.
To update the iKVM firmware using RACADM, open a serial/Telnet/SSH text console to CMC, log in, and type: racadm fwupdate -g -u -a < TFTP server IP address or
FQDN> -d < filepath/filename > -m kvm
For example: racadm fwupdate -gua 192.168.0.10 -d ikvm.bin -m kvm
For more information about the fwupdate subcommand, see the fwupdate command section in the Command Line Reference Guide for iDRAC6 and
CMC .
Troubleshooting
NOTE: If you have an active console redirection session and a lower resolution monitor is connected to the iKVM, the server console resolution may reset if the server is selected on the local console. If the server is running a Linux operating system, an X11 console may not be viewable on the local monitor. Pressing
<Ctrl><Alt><F1> at the iKVM switches Linux to a text console.
Using the iKVM Module 355
Table 10-6. Troubleshooting iKVM
Problem
The message "User has been disabled by
CMC control" appears on the monitor connected to the front panel.
The rear panel access does not work.
Likely Cause and Solution
The front panel connection has been disabled by CMC.
You can enable the front panel using either the CMC Web interface or
RACADM.
To enable the front panel using the Web interface:
1 Log in to the CMC Web interface.
2
3
Select iKVM in the system tree.
Click the Setup tab.
4 Select the Front Panel USB/Video
Enabled check box.
5 Click Apply to save the setting.
To enable the front panel using
RACADM, open a serial/Telnet/SSH text console to CMC, log in, and type: racadm config -g cfgKVMInfo o cfgKVMAccesToCMCEnable 1
The front panel setting is enabled by
CMC, and a monitor is currently connected to the front panel.
Only one connection is allowed at a time.
The front panel connection has precedence over ACI and the rear panel.
For more information about connection
precedence, see "iKVM Connection
356 Using the iKVM Module
Table 10-6. Troubleshooting iKVM (continued)
Problem
The message "User has been disabled as another appliance is currently tiered" appears on the monitor connected to the rear panel.
The iKVM’s amber LED is blinking.
Likely Cause and Solution
A network cable is connected to the iKVM
ACI port connector and to a secondary
KVM appliance.
Only one connection is allowed at a time.
The ACI tiering connection has precedence over the rear panel monitor connection. The precedence order is front panel, ACI, and then rear panel.
There are three possible causes:
There is problem with the iKVM , for which the iKVM requires reprogramming. To fix the problem, follow the instructions for updating
iKVM firmware (see "Updating the iKVM
The iKVM is reprogramming the CMC
Console Interface.
In this case, the CMC
Console is temporarily unavailable and represented by a yellow dot in the OSCAR interface. This process takes up to
15 minutes.
The iKVM firmware has detected a hardware error.
For additional information, view the iKVM status.
To view iKVM status using the Web interface:
1 Log in to the CMC Web interface.
2 Select iKVM in the system tree.
To view iKVM status using RACADM, open a serial/Telnet/SSH text console to
CMC, log in, and type: racadm getkvminfo
Using the iKVM Module 357
Table 10-6. Troubleshooting iKVM (continued)
Problem
My iKVM is tiered through the ACI port to an external KVM switch, but all of the entries for the ACI connections are unavailable.
All of the states are showing a yellow dot in the OSCAR interface.
Likely Cause and Solution
The front panel connection is enabled and has a monitor connected. Because the front panel has precedence over all other iKVM connections, the ACI and rear panel connectors are disabled.
To enable your ACI port connection, you must first disable front panel access or remove the monitor connected to the front panel. The external KVM switch
OSCAR entries become active and accessible.
To disable the front panel using the
Web interface:
1 Log in to the CMC Web interface.
2
3
Select iKVM in the system tree.
Click the Setup tab.
4 Clear (un-check) the Front Panel
USB/Video Enabled check box.
5 Click Apply to save the setting.
To disable the front panel using
RACADM, open a serial/Telnet/SSH text console to CMC, log in, and type: racadm config -g cfgKVMInfo o cfgKVMFrontPanelEnable 0
358 Using the iKVM Module
Table 10-6. Troubleshooting iKVM (continued)
Problem
In the OSCAR menu, the Dell CMC connection is displaying a red X, and I cannot connect to CMC.
The slot name for a server is displayed as
"Initializing" in OSCAR, and I cannot select it.
Likely Cause and Solution
There are two possible causes:
The Dell CMC console has been disabled.
In this case, you can enable it using either the CMC Web interface or
RACADM.
To enable the Dell CMC console using the Web interface:
1 Log in to the CMC Web interface.
2
3
Select iKVM in the system tree.
Click the Setup tab.
4
5
Select the Allow access to CMC CLI from iKVM check box.
Click Apply to save the setting.
To enable the Dell CMC connection using RACADM, open a serial/Telnet/SSH text console to CMC, log in, and type: racadm config -g cfgKVMInfo o cfgKVMAccessToCMCEnable 1
CMC is unavailable because it is initializing, switching over to the standby
CMC, or reprogramming.
In this case, simply wait until CMC finishes initializing.
Either the server is initializing or the iDRAC on that server failed initialization.
First, wait 60 seconds. If the server is still initializing, the slot name appears as soon as initialization is complete, and you can select the server.
If, after 60 seconds, OSCAR still indicates that the slot is initializing, remove and then re-insert the server in the chassis.
This action allows iDRAC to re-initialize.
Using the iKVM Module 359
360 Using the iKVM Module
11
I/O Fabric Management
The chassis can hold up to six I/O modules (IOMs), each of which can be pass-through or switch modules.
The IOMs are classified into three groups—A, B, and C. Each group has two slots—Slot 1 and Slot 2. The slots are designated with letters, from left to right, across the back of the chassis: A1 | B1 | C1 | C2 | B2 | A2. Each server has slots for two mezzanine cards (MCs) to connect to the IOMs. The MC and the corresponding IOM must have the same fabric.
Chassis IO is segregated into 3 discrete data paths by letter: A, B and C.
These paths are described as “FABRICS” and support Ethernet, Fibre
Channel or InfiniBand. These discrete fabric paths are split into 2 IO
“Banks”, bank one and two. Each server IO adapter (Mezzanine Card or
LOM) can have either 2 or 4 ports depending on capability. These ports are split out evenly to IOM banks one and two to allow for redundancy. When you deploy your Ethernet, iSCSI or FibreChannel networks, span their redundant links across banks one and two for maximum availability. We denote the discrete IOM with the fabric Identifier and the Bank number.
Example: “A1” denotes Fabric “A” in bank “1”. “C2” Denotes Fabric “C” in
Bank “2”.
The chassis supports three fabric or protocol types. The IOMs and Mezzanine
Cards in a group must have the same or compatible fabric types.
• Group A IOMS are always connected to the servers' on-board Ethernet adapters; the fabric type of Group A is always Ethernet.
• For Group B, the IOM slots are permanently connected to the first MC
(mezzanine card) slot in each server module.
• For Group C , the IOM slots are permanently connected to the second MC
(mezzanine card) in each server module.
NOTE: In the CMC CLI, IOMs are referred to by the convention, switchn :
A1=switch-1, A2=switch-2, B1=switch-3, B2=switch-4, C1=switch-5, and C2= switch-6.
I/O Fabric Management 361
Fabric Management
Fabric management helps avoid electrical, configuration, or connectivity related problems due to installation of an IOM or MC that has an incompatible fabric type from the chassis' established fabric type. Invalid hardware configurations could cause electric or functional problems to the chassis or its components. Fabric management prevents invalid configurations from powering on.
Figure 11-1 shows the location of IOMs in the chassis. The location of each
IOM is indicated by its group number (A, B, or C).These discrete fabric paths are split into two IO Banks, bank one and two. On the chassis, the IOM slot names are marked A1, A2, B1, B2, C1, and C2.
Figure 11-1. Rear View of a Chassis, Showing the Location of the IOMs
1 2
362
1 Bank 1 (Slots A1, B1, C1)
I/O Fabric Management
2 Bank 2 (Slots A2, B2, C2)
CMC creates entries in both the hardware log and CMC logs for invalid hardware configurations.
For example:
• An Ethernet MC connected to a Fibre Channel IOM is an invalid configuration. However, an Ethernet MC connected to both an Ethernet switch and an Ethernet pass-through IOM installed in the same IOM group is a valid connection.
• A Fibre Channel pass-through IOM and a fibre channel switch IOM in slots B1 and B2 is a valid configuration if the first MCs on all of the servers are also fibre channel. In this case, CMC powers-on the IOMs and the servers. However, certain fibre channel redundancy software may not support this configuration; not all valid configurations are necessarily supported configurations.
NOTE: Fabric verification for server IOMs and MCs is performed only when the chassis is powered on. When the chassis is on standby power, the iDRACs on the server modules remain powered off and thus are unable to report the server's MC fabric type. The MC fabric type may not be reported in the CMC user interface until the iDRAC on the server is powered on. Additionally, if the chassis is powered on, fabric verification is performed when a server or IOM is inserted (optional). If a fabric mismatch is detected, the server or IOM is allowed to power on and the status LED flashes Amber.
Invalid Configurations
There are three types of invalid configurations:
• Invalid MC or LOM configuration, where a newly installed servers’s fabric type is different from the existing IOM fabric
• Invalid IOM-MC configuration, where a newly installed IOM’s fabric type and the resident MC’s fabric types do not match or are incompatible
• Invalid IOM-IOM configuration, where a newly installed IOM has a different or incompatible fabric type from an IOM already installed in its group
I/O Fabric Management 363
Invalid Mezzanine Card (MC) Configuration
An invalid MC configuration occurs when a single server’s LOM or MC is not supported by its corresponding IOM. In this case, all the other servers in the chassis can be running, but the server with the mismatched MC card does not be allowed to power on. The power button on the server flashes Amber to alert a fabric mismatch. For information about CMC and hardware logs, see
"Viewing the Event Logs" on page 398 .
Invalid IOM-Mezzanine Card (MC) Configuration
The mismatched IOM is held in the power-off state. CMC adds an entry to
CMC and hardware logs noting the invalid configuration and specifying the
IOM name. CMC causes the error LED on the offending IOM to blink. If
CMC is configured to send alerts, it sends e-mail and/or SNMP alerts for this
event. For information about CMC and hardware logs, see "Viewing the
Invalid IOM-IOM Configuration
CMC holds the newly installed IOM in powered-off state, causes the IOM’s error LED to blink, and creates entries in CMC and hardware logs about the
mismatch. For information about CMC and hardware logs, see "Viewing the
Fresh Power-up Scenario
When the chassis is plugged in and powered up, the I/O modules have priority over the servers. The first IOM in each group is allowed to power up before the others. At this time, no verification of their fabric types is performed. If there is no IOM on the first slot of a group, the module on the second slot of that group powers up. If both slots have IOMs, the module in the second slot is compared for consistency against the one in the first.
After the IOMs power up, the servers power up, and CMC verifies the servers for fabric consistency.
A pass-through module and switch are allowed in the same group as long as their fabric is identical. Switches and pass-through modules can exist in the same group even if they are manufactured by different vendors.
364 I/O Fabric Management
Monitoring IOM Health
The health status for the IOMs can be viewed in two ways: from the Chassis
Graphics section on the Chassis Status page or the I/O Modules Status page.
The Chassis Graphics page provides a graphical overview of the IOMs installed in the chassis.
To view health status of the IOMs using Chassis Graphics:
1 Log in to the CMC Web interface.
2 The Chassis Status page is displayed. The right section of Chassis
Graphics depicts the rear view of the chassis and contains the health status for the IOMs. IOM health status is indicated by the color of the IOM subgraphic:
• Green - IOM is present, powered on and communicating with CMC; there is no indication of an adverse condition.
• Amber - IOM is present, but may or may not be powered on, or may or may not be communicating with CMC; an adverse condition may exist.
• Gray - IOM is present and not powered on. It is not communicating with CMC and there is no indication of an adverse condition.
3 Use the cursor to hover over an individual IOM subgraphic and a corresponding text hint or screen tip is displayed. The text hint provides additional information on that IOM.
4 The IOM subgraphic is hyperlinked to the corresponding CMC GUI page to provide immediate navigation to the I/O Module Status page associated with that IOM.
To view the health status of all IOMs using the I/O Modules Status page:
1 Log in to the CMC Web interface.
2 Select I/O Modules in the Chassis menu in the system tree.
3 Click the Properties tab.
I/O Fabric Management 365
4 Click the Status subtab. The I/O Modules Status page displays.
Table 11-1. I/O Modules Status Information
Item
Slot
Present
Health
Description
Displays the location of the I/O module in the chassis by group number (A, B, or C) and Bank (1 or 2). IOM Enumeration: A1 , A2 ,
B1 , B2 , C1 , or C2 .
Displays whether the IOM is present ( Yes or No ).
OK Indicates that the IOM is present and communicating with CMC. In the event of a communication failure between CMC and the server, CMC cannot obtain or display health status for the IOM.
Informational Displays information about the IOM when no change in health status (OK, Warning, Severe) has occurred.
Warning Indicates that warning alerts have been issued, and c orrective action must be taken.
If corrective actions are not taken, it could lead to critical or severe failures that can affect the integrity of the IOM.
Examples of conditions causing Warnings: IOM fabric mismatch with the server's mezzanine card fabric; invalid IOM configuration, where the newly installed IOM does not match the existing IOM on the same group.
Severe Indicates that at least one Failure alert has been issued. Severe status represents a system failure on the IOM, and corrective action must be taken immediately .
Examples of conditions causing Severe status:
Failure in IOM detected; IOM was removed.
NOTE: Any change in health is logged to both the hardware and CMC
log. For more information, see "Viewing the Event Logs" on page 398.
366 I/O Fabric Management
Table 11-1. I/O Modules Status Information (continued)
Item
Fabric
Description
Displays the type of fabric for the IOM: Gigabit Ethernet, 10GE
XAUI, 10GE KR, 10GE XAUI KR, FC 4 Gbps, FC 8 Gbps, SAS 3
Gbps, SAS 6 Gbps, Infiniband SDR, Infiniband DDR, Infiniband
QDR, PCIe Bypass Generation 1, PCIe Bypass Generation 2.
NOTE: Knowing the fabric types of the IOMs in your chassis is critical in preventing IOM mismatches within the same group. For information
about I/O fabric, see "I/O Fabric Management" on page 361.
Name
Launch IOM
Management
Console
Displays the IOM product name.
If the button is present for a particular I/O module, clicking it launches the IOM management console for that I/O module in a new browser window or tab.
NOTE: This option is only available for the managed switch I/O modules. It is not available for pass-through I/O modules or unmanaged Infiniband switches.
NOTE: If an I/O Module is inaccessible because it is powered off, its LAN interface is disabled, or the module has not been assigned a valid IP address, the Launch IOM GUI option is not displayed for that I/O Module.
NOTE: You are prompted to log in to I/O module management interface.
NOTE: You can configure the I/O module IP address using CMC
GUI, as described in "Configuring Network Settings for an
Role When linking I/O modules together, the Role displays the I/O
Module stacking membership. Member means the module is part of a stack set. Master indicates the module is a primary access point.
Power Status Displays the power status of the IOM: On , Off , or N/A (Absent).
Service Tag Displays the service tag for the IOM. The service tag is a unique identifier provided by Dell for support and maintenance.
Any change in health is logged to both the hardware and CMC log.
For more information, see "Viewing the Event Logs" on page 398.
NOTE: Pass-throughs do not have service tags. Only switches have service tags.
I/O Fabric Management 367
Viewing the Health Status of an Individual IOM
The I/O Module Status page (separate from the I/O Modules Status page) provides an overview of an individual IOM.
To view the health status of an individual IOM:
1 Log in to the CMC Web interface.
2 Expand I/O Modules in the system tree. All of the IOMs (1–6) appear in the expanded I/O Modules list.
3 Click the IOM you want to view in the I/O Modules list in the system tree.
4 Click the Status subtab. The I/O Modules Status page displays.
Table 11-2. I/O Module Health Status Information
Item
Location
Name
Present
Health
Description
Displays the location of the IOM in the chassis by group number
(A, B, or C) and slot number (1 or 2). Slot names: A1 , A2 , B1 , B2 ,
C1 , or C2 .
Displays name of the IOM.
Displays whether the IOM is Present or Absent .
OK Indicates that the IOM is present and communicating with CMC. In the event of a communication failure between CMC and the server, CMC cannot obtain or display health status for the IOM.
Informational Displays information about the IOM when no change in health status (OK, Warning, Severe) has occurred.
Examples of conditions causing Informational status: the IOM presence was detected; a user requested IOM power cycle.
368 I/O Fabric Management
Table 11-2. I/O Module Health Status Information (continued)
Item
Power Status
Service Tag
Fabric
Description
Warning Indicates that warning alerts have been issued, and c orrective action must be taken . If corrective actions are not taken, it could lead to critical or severe failures that can affect the integrity of the IOM.
Examples of conditions causing Warnings:
IOM fabric mismatch with the server's mezzanine card fabric; invalid IOM configuration, where the newly installed
IOM does not match the existing IOM on the same group.
Severe Indicates that at least one Failure alert has been issued. Severe status represents a system failure on the IOM, and corrective action must be taken immediately .
Examples of conditions causing Severe status:
Failure in IOM detected; IOM was removed.
NOTE: Any change in health is logged to both the hardware and CMC
log. For information on viewing logs, see "Viewing the Hardware Log"
on page 398 and "Viewing the CMC Log" on page 400.
Displays the power status of the IOM: On , Off , or N/A (Absent).
Displays the service tag for the IOM. The service tag is a unique identifier provided by Dell for support and maintenance.
Displays the type of fabric for the IOM: Gigabit Ethernet, 10GE
XAUI, 10GE KR, 10GE XAUI KR, FC 4 Gbps, FC 8 Gbps, SAS 3
Gbps, SAS 6 Gbps, Infiniband SDR, Infiniband DDR, Infiniband
QDR, PCIe Bypass Generation 1, PCIe Bypass Generation 2.
NOTE: Knowing the fabric types of the IOMs in your chassis is critical in preventing IOM mismatches within the same group. For information
about I/O fabric, see "I/O Fabric Management" on page 361.
I/O Fabric Management 369
Table 11-2. I/O Module Health Status Information (continued)
Item
MAC Address Displays the MAC address for the IOM. The MAC address is a unique address assigned to a device by the hardware vendor as a means for identification.
NOTE: Pass-throughs do not have MAC addresses. Only switches have MAC addresses.
Role
Description
Displays the I/O module stacking membership when modules are linked together:
• Member - the module is part of a stack set
• Master - the module is a primary access point.
Configuring Network Settings for an Individual IOM
The I/O Modules Setup page allows you to specify the network settings for the interface used to manage the IOM. For Ethernet switches, the out-of-band management port (IP address) is what is configured. The in-band management port (that is, VLAN1) is not configured using this interface.
NOTE: To change settings on the I/O Modules Configuration page, you must have
Fabric A Administrator privileges to configure IOMs in Group A; Fabric B
Administrator privileges to configure IOMs in Group B; or Fabric C Administrator privileges to configure IOMs in Group C.
NOTE: For Ethernet switches, the in-band (VLAN1) and out-of-band management IP addresses cannot be the same or on the same network; this results in the out-of-band IP address not being set. Refer to the IOM documentation for the default in-band management IP address.
NOTE: Only those IOMs present in the chassis are displayed.
NOTE: Do not configure I/O module network settings for Ethernet pass-through and
Infiniband switches.
370 I/O Fabric Management
To configure the network settings for an individual IOM:
1 Log in to the CMC Web interface.
2 Click I/O Modules in the system tree. Click the Setup subtab. The
Configure I/O Modules Network Settings page displays.
3 To configure network settings for I/O modules, type/select values for the following properties, and then click Apply .
NOTE: Only IOMs that are powered on can be configured.
NOTE: The IP address set on the IOMs from CMC is not saved to the switch's permanent startup configuration. To save the IP address configuration permanently, you must enter the connect switch-n command, or racadm connect switch -n RACADM command, or use a direct interface to the IOM GUI to save this address to the startup configuration file.
Table 11-3. Configure I/O Module Network Settings
Item
Slot
Name
Power State
Description
Displays the location of the IOM in the chassis by group number
(A, B, or C) and slot number (1 or 2). Slot names: A1, A2, B1, B2,
C1, or C2. (The Slot value cannot be changed.)
Displays the IOM product name. (The IOM name cannot be changed.)
Displays the Power State of the IOM. (The Power State cannot be changed from this page.)
I/O Fabric Management 371
Table 11-3. Configure I/O Module Network Settings (continued)
Item Description
DHCP Enabled Enables the IOM on the chassis to request and obtain an
IP address from the Dynamic Host Configuration Protocol (DHCP) server automatically.
Default: Checked (enabled).
If this option is checked, the IOM retrieves IP configuration
(IP address, subnet mask, and gateway) automatically from a
DHCP server on your network.
NOTE: When this feature is enabled, the IP Address, Gateway, and Subnet Mask property fields (located immediately adjacent following this option) are inactivated, and any previously entered values for these properties are ignored.
If this option is not checked, you must manually enter a valid
IP address, gateway, and subnet mask in the corresponding text fields immediately following this option.
IP Address Specifies the IP address for the IOM network interface.
Subnet Mask Specifies the subnet mask for the IOM network interface.
Gateway Specifies the gateway for the IOM network interface.
372 I/O Fabric Management
Troubleshooting IOM Network Settings
The following list contains troubleshooting items for IOM network settings:
• CMC can read the IP address setting too quickly after a configuration change; it displays 0.0.0.0
after clicking Apply. You must hit the refresh button in order to see if the IP address is set correctly on the switch.
• If an error is made in setting the IP/mask/gateway, the switch does not set the IP address and returns a 0.0.0.0
in all fields. Common errors are:
• Setting the out-of-band IP address to be the same as, or on the same network as, the in-band management IP address.
• Entering an invalid subnet mask.
• Setting the default gateway to an address that is not on a network that is directly connected to the switch.
For more information on IOM network settings, refer to the Dell
PowerConnect M6220 Switch Important Information document and the Dell
PowerConnect 6220 Series Port Aggregator White Paper .
I/O Fabric Management 373
374 I/O Fabric Management
Troubleshooting and Recovery
12
Overview
This section explains how to perform tasks related to recovering and troubleshooting problems on the remote system using the CMC
Web interface.
• Gathering Configuration information, error status and error logs.
• Managing power on a remote system.
• Viewing chassis information.
• Viewing the event logs.
• Using the Diagnostic Console.
• Reset Components.
• Troubleshooting Network Time Protocol (NTP) problems.
• Troubleshooting network problems.
• Troubleshooting alerting problems.
• Resetting forgotten administrator password.
• Error codes and logs.
Chassis Monitoring Tools
Gathering Configuration information and Chassis Status and Logs
The racdump subcommand provides a single command to get comprehensive chassis status, configuration state information, and the historic event logs.
Troubleshooting and Recovery 375
376
Usage
racadm racdump
The racdump subcommand displays the following information:
• General system/RAC information
• CMC information
• Chassis information
• Session information
• Sensor information
• Firmware build information
Supported Interfaces
• CLI RACADM
• Remote RACADM
• Telnet RACADM
RACDUMP command can be run remotely from the serial, Telnet, or SSH console command prompt or through a normal command prompt.
To list syntax and command-line options for RACDUMP subcommands, type: racadm help <racdump>
CLI RACDUMP
Racdump includes the following subsystems and aggregates the following
RACADM commands:
Table 12-1. Subsystems and RACADM Commands
General System/RAC information
Session information
Sensor information
Switches information (IO Module) getsysinfo getssinfo getsensorinfo getioinfo
Troubleshooting and Recovery
Table 12-1. Subsystems and RACADM Commands
Mezzanine card information (Daughter card)
All modules information
Power budget information
KVM information
NIC information (CMC module)
Redundancy information
Trace log information
RAC event log
System event log getdcinfo getmodinfo getpbinfo getkvminfo getniccfg getredundancymode gettracelog gettraclog getsel
Usage racadm racdump
Remote RACDUMP
Remote RACADM is a client side utility, which can be executed from a management station through the out of band network interface. A remote capability option (-r) is provided that allows you to connect to the managed system and execute RACADM subcommands from a remote console or management station. To use the remote capability, you need a valid user name (-u option) and password (-p option), and CMC IP address.
NOTE: When using the RACADM remote capability, you must have write permissions on the folders where you are using the RACADM subcommands involving file operations, for example:
– racadm getconfig -f <file name>
– racadm sslcertdownload -t <type> [-f
<filename>]
Remote RACDUMP Usage
To use the RACDUMP subcommand remotely, type the following commands: racadm -r <CMC IP address> -u <username> -p <password>
Troubleshooting and Recovery 377
<subcommand> <subcommand options> racadm -i -r <CMC IP address> <subcommand> <subcommand options>
NOTE: The -i option instructs RACADM to interactively prompt for user name and password. Without the -i option, you must provide the user name and password in the command using the -u and -p options.
For example: racadm -r 192.168.0.120 -u root -p calvin racdump racadm -i -r 192.168.0.120 racdump
If the HTTPS port number of CMC has been changed to a custom port other than the default port (443), the following syntax must be used: racadm -r <CMC IP address>:<port> -u <username> -p
<password> <subcommand> <subcommand options> racadm -i -r <CMC IP address>:<port> <subcommand>
<subcommand options>
Telnet RACDUMP
SSH/Telnet RACDUMP is used to refer to the RACDUMP command usage from a SSH or Telnet prompt.
For more information on RACDUMP instruction see the section "Using the
RACADM Command Line Interface" on page 69 and the "
CMC
Administrators Reference Guide ."
Configuring LEDs to Identify Components on the Chassis
You can set component LEDs for all or individual components (chassis, servers, and IOMs) to blink as a means of identifying the component on the chassis.
NOTE: To modify these settings, you must have Chassis Configuration
Administrator privilege.
378 Troubleshooting and Recovery
Using the Web Interface
To enable blinking for one, multiple, or all component LEDs:
1 Log in to the CMC Web interface.
2 Click Chassis in the system tree.
3 Click the Troubleshooting tab.
4 Click the Identify subtab. The Identify page displays, featuring a list of all components on the chassis.
5 To enable blinking for a component LED, check the box beside the device name and then click Blink .
6 To disable blinking for a component LED, check the box beside the device name and then click UnBlink .
Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type: racadm setled -m < module > [-l < ledState >] where < module > specifies the module whose LED you want to configure.
Configuration options:
• servern where n =1–16
• switchn where n =1–6
• cmc-active and < ledState > specifies whether the LED should blink.
Configuration options:
• 0 — not blinking (default)
• 1 — blinking
Configuring SNMP Alerts
Simple network management protocol (SNMP) traps, or event traps , are similar to e-mail event alerts. They are used by a management station to receive unsolicited data from CMC.
Troubleshooting and Recovery 379
You can configure CMC to generate event traps. Table 12-2 provides an
overview of the events that trigger SNMP and e-mail alerts. For information
on e-mail alerts, see "Configuring E-mail Alerts" on page 385.
NOTE: Starting with CMC version 2.10, SNMP is now IPv6 enabled. You can include an IPv6 address or fully qualified domain name (FQDN) in the destination for an event alert.
Table 12-2. Chassis Events That Can Generate SNMP and Email Alerts
Event Description
Fan Probe Failure
Battery Probe Warning
Temperature Probe
Warning
The temperature is approaching excessively high or low limits.
Temperature Probe Failure The temperature is either too high or too low for proper operation.
Redundancy Degraded Redundancy for the fans and/or power supplies has been reduced.
Redundancy Lost
A fan is running too slow or not at all.
A battery has stopped functioning.
Power Supply Warning
Power Supply Failure
Power Supply Absent
Hardware Log Failure
Hardware Log Warning
Server Absent
Server Failure
KVM Absent
KVM Failure
No redundancy remains for the fans and/or power supplies.
The power supply is approaching a failure condition.
The power supply has failed.
An expected power supply is not present.
The hardware log is not functioning.
The hardware log is almost full.
An expected server is not present.
The server is not functioning.
An expected KVM is not present.
The KVM is not functioning.
380 Troubleshooting and Recovery
Table 12-2. Chassis Events That Can Generate SNMP and Email Alerts (continued)
Event Description
IOM Absent
IOM Failure
An expected IOM is not present.
The IOM is not functioning.
Firmware Version Mismatch There is a firmware mismatch for the chassis or server firmware.
Chassis Power Threshold
Error
SDCARD Absent
Power consumption within the chassis reached the
System Input Power Cap.
There is no media in the CMC’s Secure Digital (SD) card slot, and a configured CMC feature requires it.
SDCARD Error An error occurred while accessing the media in the
CMC's Secure Digital (SD) card slot.
You can add and configure SNMP alerts using the Web interface or
RACADM.
Using the Web Interface
NOTE: To add or configure SNMP alerts, you must have Chassis Configuration
Administrator privilege.
NOTE: For added security, it is strongly recommended that you change the default password of the root (User 1) account. The root account is the default administrative account that ships with CMC. To change the default password for the root account, click User ID 1 to open the User Configuration page. Help for that page is available through the Help link at the top right corner of the page.
1 Log in to the CMC Web interface.
2 Select Chassis in the system tree.
3 Click the Alerts tab. The Chassis Events page appears.
4 Enable alerting: a Select the check boxes of the events for which you want to enable alerting. To enable all events for alerting, select the Select All check box.
b Click Apply to save your settings.
5 Click the Traps Settings subtab.The Chassis Event Alert Destinations page displays.
Troubleshooting and Recovery 381
382
6 Type a valid address in an empty Destination field.
NOTE: A valid address is an address that receives the trap alerts. Use the
"quad-dot" IPv4 format, standard IPv6 address notation, or FQDN. For example:
123.123.123.123 or 2001:db8:85a3::8a2e:370:7334 or dell.com
7 Type the SNMP Community String to which the destination management station belongs.
NOTE: The community string on the Chassis Event Alert Destinations page differs from the community string on the Chassis ï‚® Network ï‚® Services page.
The SNMP traps community string is the community that CMC uses for outbound traps destined to management stations. The community string on the Chassis ï‚® Network ï‚® Services page is the community string that management stations use to query the SNMP daemon on CMC.
8 Click Apply to save your changes.
To test an event trap for an alert destination:
1 Log in to the CMC Web interface.
2 Select Chassis in the system tree.
3 Click the Alerts tab. The Chassis Events page displays.
4 Click the Traps Settings tab. The Chassis Event Alert Destinations page displays.
5 Click Send in the Test Trap column beside the destination.
NOTE: Specify trap destinations as appropriately-formatted numeric addresses
(IPv6 or IPv4), or Fully-qualified domain names (FQDNs). Choose a format that is consistent with your networking technology/infrastructure. The Test Trap functionality is unable to detect improper choices based on current network configuration (e.g. use of an IPv6 destination in an IPv4-only environment).
Using RACADM
1 Open a serial/Telnet/SSH text console to CMC and log in.
NOTE: Only one filter mask may be set for both SNMP and e-mail alerting.
You may skip step 2 if you have already selected filter mask.
2 Enable alerting by typing: racadm config -g cfgAlerting -o cfgAlertingEnable 1
3 Specify the events for which you want CMC to generate by typing:
Troubleshooting and Recovery
racadm config -g cfgAlerting -o cfgAlertingFilterMask < mask value > where <mask value> is a hex value between 0x0 and 0xffffffff.
To obtain the mask value, use a scientific calculator in hex mode and add the second values of the individual masks (1, 2, 4, etc.) using the <OR> key.
For example, to enable trap alerts for Battery Probe Warning (0x2),
Power Supply Failure (0x1000), and KVM failure (0x80000), key 2
<OR> 1000 <OR> 200000 and press the <=> key.
The resulting hex value is 208002, and the mask value for the RACADM command is 0x208002.
Table 12-3. Event Traps Filter Masks
Event
Fan Probe Failure
Battery Probe Warning
Temperature Probe Warning
Temperature Probe Failure
Redundancy Degraded
Redundancy Lost
Power Supply Warning
Power Supply Failure
Power Supply Absent
Hardware Log Failure
Hardware Log Warning
Server Absent
Server Failure
KVM Absent
KVM Failure
IOM Absent
Filter Mask Value
0x2000
0x4000
0x8000
0x10000
0x20000
0x40000
0x80000
0x100000
0x1
0x2
0x8
0x10
0x40
0x80
0x800
0x1000
Troubleshooting and Recovery 383
Table 12-3. Event Traps Filter Masks (continued)
Event
IOM Failure
Firmware Version Mismatch
Chassis Power Threshold Error
SDCARD Absent
SDCARD Error
Chassis Group Error
Filter Mask Value
0x200000
0x00400000
0x01000000
0x02000000
0x04000000
0x8000000
4 Enable traps alerting by typing: racadm config -g cfgTraps -o cfgTrapsEnable 1 -i
< index > where <index> is a value 1–4. The index number is used by CMC to distinguish up to four configurable destinations for traps alerts.
Destinations may be specified as appropriately formatted numeric
Addresses (IPv6 or IPv4), or Fully-qualified domain names (FQDNs).
5 Specify a destination IP address to receive the traps alert by typing: racadm config -g cfgTraps -o cfgTrapsAlertDestIPAddr <IP address> -i < index > where <IP address> is a valid destination, and <index> is the index value you specified in step 4.
6 Specify the community name by typing: racadm config -g cfgTraps -o cfgTrapsCommunityName
<community name> -i < index > where <community name> is the SNMP community to which the chassis belongs, and <index> is the index value you specified in steps 4 and 5.
384 Troubleshooting and Recovery
You can configure up to four destinations to receive traps alerts. To add more destinations, repeat steps 2–6.
NOTE: The commands in steps 2–6 overwrites any existing settings configured for the index you specify (1–4). To determine whether an index has previously configured values, type: racadm getconfig -g cfgTraps -i < index configured, values appear for the cfgTrapsAlertDestIPAddr and cfgTrapsCommunityName objects.
>. If the index is
To test an event trap for an alert destination, type: racadm testtrap -i < index > where <index> is a value 1–4 representing the alert destination you want to test. If you are unsure of the index number, type: racadm getconfig -g cfgTraps -i < index >
Configuring E-mail Alerts
When CMC detects a chassis event, such as an environmental warning or a component failure, it can be configured to send an e-mail alert to one or more e-mail addresses.
Table 12-2 provides an overview of the events that trigger e-mail and SNMP
alerts. For information on SNMP alerts, see "Configuring SNMP Alerts" on page 379.
You can add and configure e-mail alerts using the Web interface or
RACADM.
Using the Web Interface
NOTE: To add or configure e-mail alerts, you must have Chassis Configuration
Administrator privilege.
1 Log in to the CMC Web interface.
2 Select Chassis in the system tree.
3 Click the Alerts tab. The Chassis Events page appears.
4 Enable alerting: a b
Select the check boxes of the events for which you want to enable alerting. To enable all events for alerting, select the Select All check box.
Click Apply to save your settings.
Troubleshooting and Recovery 385
5 Click the Email Alert Settings subtab. The Email Alert Destinations page displays.
6 Specify the SMTP server IP address: a Locate the SMTP (Email) Server field, and then type the SMTP hostname or IP address.
b
NOTE: You must configure the SMTP e-mail server to accept relayed emails from the CMC's IP address, a feature which is normally turned off in most mail servers due to security concerns. For instructions as to how to accomplish this in a secure manner, refer to the documentation that came with your SMTP server.
Enter the desired originator e-mail for the alert, or leave it blank to use the default e-mail originator. The default is cmc@<IP_address> where <IP_address> is the IP address of CMC. To enter a value, the syntax of the e-mail name is <emailname>[@<domain>], and an email domain can be optionally specified.
If @<domain> is not specified and there is an active CMC network domain, then the e-mail address of <emailname>@<cmc_domain> is used as the source e-mail. If @<domain> is not specified and
CMC has no active network domain, then the IP address of CMC is used (for example, <emailname>@<IP_address>). c Click Apply to save your changes.
7 Specify the e-mail address(es) that receive the alerts: a b c
Type a valid e-mail address in an empty Destination Email
Address field.
Enter an optional Name . This is the name of the entity receiving the e-mail. If a name is entered for an invalid e-mail address, it is ignored.
Click Apply to save your settings.
386 Troubleshooting and Recovery
To send a test e-mail to an e-mail alert destination:
1 Log in to the CMC Web interface.
2 Select Chassis in the system tree.
3 Click the Alerts tab. The Chassis Events page appears.
4 Click the Email Alert Settings subtab. The Email Alert Destinations page displays.
5 Click Send in the Destination Email Address column beside the destination.
Using RACADM
1 Open a serial/Telnet/SSH text console to CMC and log in.
2 Enable alerting by typing: racadm config -g cfgAlerting -o cfgAlertingEnable 1
NOTE: Only one filter mask may be set by both SNMP and e-mail alerting.
You may skip step 3 if you have already set a filter mask.
3 Specify the events for which you want CMC to generate by typing: racadm config -g cfgAlerting -o cfgAlertingFilterMask < mask value > where <mask value> is a hexadecimal value between 0x0 and 0xffffffff and must be expressed with the leading 0x
characters. Table 12-3 provides
filter masks for each event type. For instructions on calclulating the hex
value for the filter mask you want to enable, see step 3 on "Using
4 Enable e-mail alerting by typing: racadm config -g cfgEmailAlert -o cfgEmailAlertEnable 1 -i < index > where <index> is a value 1–4. The index number is used by CMC to distinguish up to four configurable destination e-mail addresses.
5 Specify a destination e-mail address to receive the e-mail alerts by typing: racadm config -g cfgEmailAlert -o cfgEmailAlertAddress <email address> -i < index >
Troubleshooting and Recovery 387
where <email address> is a valid e-mail address, and <index> is the
index value you specified in step 4.
6 Specify the name of the party receiving the e-mail alert by typing: racadm config -g cfgEmailAlert -o cfgEmailAlertEmailName <email name> -i < index > where <email name> is the name of the person or group receiving the e-mail alert, and <index>
characters, dashes, underscores, and periods. Spaces are not valid.
7 Setup the SMTP host by configuring the cfgRhostsSmtpServerIpAddr database property by typing: racadm config -g cfgRemoteHosts -o cfgRhostsSmtpServerIpAddr host.domain
where host.domain
is a full-qualified domain name.
You can configure up to four destination e-mail addresses to receive e-mail
alerts. To add more e-mail addresses, repeat step 2–step 6.
NOTE: The commands in steps 2–6 overwrite any existing settings configured for the index you specify (1–4). To determine whether an index has previously configured values, type: racadm getconfig -g cfgEmailAlert -i < configured, values appear for the cfgEmailAlertAddress and cfgEmailAlertEmailName objects.
index >. If the index is
First Steps to Troubleshooting a Remote System
The following questions are commonly used to troubleshoot high-level problems in the managed system:
1 Is the system powered on or off?
2 If powered on, is the operating system functioning, crashed, or just frozen?
3 If powered off, did the power turn off unexpectedly?
388 Troubleshooting and Recovery
Monitoring Power and Executing Power Control
Commands on the Chassis
You can use the Web interface or RACADM to:
• View the system’s current power status.
• Perform an orderly shutdown through the operating system when rebooting, and power the system on or off.
For information about power management on CMC and configuring power
budget, redundancy, and power control, see "Power Management" on page 289.
Viewing Power Budget Status
For instructions on viewing power budget status for the chassis, servers,
and PSUs using either the Web interface or RACADM, see "Viewing Power
Consumption Status" on page 311.
Executing a Power Control Operation
For instructions on powering on, powering off, resetting, or power-cycling the
system using the CMC Web interface or RACADM, see "Executing Power
Control Operations on the Chassis" on page 327, "Executing Power Control
Operations on an IOM" on page 329, and "Executing Power Control
Operations on a Server" on page 330.
Power Troubleshooting
Use the items below to assist in troubleshooting power supply and power-related issues:
• Problem: Configured the Power Redundancy Policy to AC Redundancy , and a Power Supply Redundancy Lost event was raised.
– Resolution A : This configuration requires at least one power supply in side 1 (the left three slots) and one power supply in side 2 (the right three slots) to be present and functional in the modular enclosure.
Additionally the capacity of each side must be enough to support the total power allocations for the chassis to maintain AC redundancy .
(For full AC Redundancy operation, ensure that a full PSU configuration of six power supplies is available.)
Troubleshooting and Recovery 389
– Resolution B: Check if all power supplies are properly connected to the two AC grids; power supplies in side 1 need to be connected to one AC grid, those in side 2 need to be connected to the other AC grid, and both AC grids need to be working. AC Redundancy is lost when one of the AC grids is not functioning.
• Problem: The PSU state is displayed as Failed (No AC), even when an
AC cord is connected and the power distribution unit is producing good AC output.
– Resolution A: Check and replace the AC cord. Check and confirm that the power distribution unit providing power to the power supply is operating as expected. If the failure still persists, call Dell customer service for replacement of the power supply.
– Resolution B: Check that the PSU is connected to the same voltage as the other PSUs. If CMC detects a PSU operating at a different voltage, the PSU is turned off and marked Failed.
• Problem: Dynamic Power Supply Engagement is enabled, but none of the power supplies display in the Standby state.
– Resolution A: There is insufficient surplus power. One or more power supplies are moved into the Standby state only when the surplus power available in the enclosure exceeds the capacity of at least one power supply.
– Resolution B: Dynamic Power Supply Engagement cannot be fully supported with the power supply units present in the enclosure. To check if this is the case, use the Web interface to turn Dynamic Power
Supply Engagement off, and then on again. A message is displayed if
Dynamic Power Supply Engagement cannot be fully supported.
• Problem: Inserted a new server into the enclosure with sufficient power supplies, but the server does not power on.
– Resolution A: Check the system input power cap setting - it might be configured too low to allow any additional servers to be powered up.
– Resolution B: Check for 110V operation. If any power supplies are connected to 110V branch circuits, you must acknowledge this as a valid configuration before servers are allowed to power on. For more details, see the power configuration settings.
390 Troubleshooting and Recovery
– Resolution C: Check the max power conservation setting. If this is set then servers are allowed to power on. For more details, see the power configuration settings.
– Resolution D: Check the server slot power priority of the slot associated with the newly inserted server, and ensure it is not lower than any other server slot power priority.
• Problem: Available power keeps changing, even when the modular enclosure configuration hasn't changed
– Resolution: CMC 1.2 and higher versions have dynamic fan power management that reduces server allocations briefly if the enclosure is operating near the peak user configured power cap; it causes the fans to be allocated power by reducing server performance to keep the input power draw below System Input Power Cap . This is normal behavior.
• Problem: 2000 W is reported as the Surplus for Peak Performance .
– Resolution: The enclosure has 2000 W of surplus power available in the current configuration, and the System Input Power Cap can be safely reduced by this amount being reported without impacting server performance.
• Problem: A subset of servers lost power after an AC Grid failure, even when the chassis was operating in the AC Redundancy configuration with six power supplies.
– Resolution: This can occur if the power supplies are improperly connected to the redundant AC grids at the time the AC grid failure occurs. The AC Redundancy policy requires that the left three power supplies to be connected to one AC Grid, and right three power supplies to be connected to other AC Grid. If two PSU are improperly connected, such as PSU3 and PSU4 are connected to the wrong
AC grids, an AC grid failure cause loss of power to the least priority servers.
Troubleshooting and Recovery 391
• Problem: The least priority servers lost power after a PSU failure.
– Resolution: This is expected behavior if the enclosure power policy was configured to No Redundancy . To avoid a future power supply failure causing servers to power off, ensure that the chassis has at least four power supplies and is configured for the Power Supply
Redundancy policy to prevent PSU failure from impacting server operation.
• Problem: Overall server performance decreases when the ambient temperature increases in the data center.
– Resolution: This can occur if the System Input Power Cap has been configured to a value that results in an increased power need by fans having to be made up by reduction in the power allocation to the servers. User can increase the System Input Power Cap to a higher value that allow for additional power allocation to the fans without an impact on server performance.
Viewing Chassis Summaries
CMC provides rollup overviews of the chassis, active and standby CMCs, iKVM, fans, temperature sensors, and I/O modules (IOMs).
Using the Web Interface
To view summaries of the chassis, CMCs, iKVM, and IOMs:
1 Log in to the CMC Web interface.
2 Select Chassis in the system tree.
3 Click the Summary tab. The Chassis Summary page displays.
Table 12-4, Table 12-5, Table 12-6, and Table 12-7 describe the information
displayed on the Chassis Summary page.
392 Troubleshooting and Recovery
Table 12-4. Chassis Summary
Item Description
Name
Model
Displays the name of the chassis. The name identifies the chassis on the network.For information on setting the name
of the chassis, see "Editing Slot Names" on page 124.
Displays the chassis model or manufacturer. For example,
PowerEdge 2900.
Service Tag
Asset Tag
Location
Displays the service tag of the chassis. The service tag is a unique identifier provided by the manufacturer for support and maintenance.
Displays the asset tag of the chassis.
Displays the location of the chassis.
CMC Failover Ready Displays ( Yes , No ) whether the standby CMC (if present) is capable of taking over in the event of a failover condition.
System Power Status Displays the system power status.
Table 12-5. CMC Summary
Item Description
Active CMC Information
Name
Description
Date/Time
Active CMC
Location
Displays the name of CMC. For example, Active CMC or
Standby CMC.
Provides a brief description of the purpose of CMC.
Displays the date and time set on the active CMC.
Displays the slot location of the active CMC.
Redundancy Mode Displays if the standby CMC is present in the chassis.
Primary Firmware
Version
Displays the firmware version of the active CMC.
Firmware Last
Updated
Hardware Version
Displays when the firmware was last updated. If no updates have occurred, this property displays as N/A .
Displays the hardware version of the active CMC.
Troubleshooting and Recovery 393
Table 12-5. CMC Summary (continued)
Item Description
MAC Address
IP Address
Gateway
Subnet Mask
Use DHCP (for
Network Interface IP
Address)
Displays the MAC address for the CMC Network Interface.
The MAC address is a unique identifier for CMC over the network.
Displays the IP address of the CMC Network Interface.
Displays the gateway of the CMC Network Interface.
Displays the subnet mask of the CMC Network Interface.
Displays whether CMC is enabled to request and obtain automatically an IP address from the Dynamic Host
Configuration Protocol (DHCP) server ( Yes or No ).
The default setting for this property is No .
Primary DNS Server Displays the primary DNS server name.
Alternate DNS Server Displays the alternate DNS server name.
Use DHCP for DNS
Domain Name (
Displays use of DHCP to acquire the DNS Domain name
Yes, No) .
DNS Domain Name Displays the DNS Domain name.
394 Troubleshooting and Recovery
Table 12-5. CMC Summary (continued)
Item Description
Standby CMC Information
Present
Standby Firmware
Version
Displays ( Yes , No ) whether a second (standby) CMC is installed.
Displays the CMC firmware version installed on the standby
CMC.
Table 12-6. iKVM Summary
Item Description
Present
Name
Displays whether the iKVM module is present (Yes or No).
Displays the name of the iKVM. The name identifies the iKVM on the network.
Displays the iKVM model or manufacturer.
Manufacturer
Part Number
Firmware Version
Hardware Version
Displays the part number for the iKVM. The part number is a unique identifier provided by the vendor. Part number naming conventions differ from vendor to vendor.
Displays the firmware version of the iKVM.
Displays the hardware version of the iKVM.
Power Status
Front Panel
USB/Video Enabled
Displays the power status of the iKVM: On , Off , N/A
(Absent).
Displays whether the front panel VGA and USB connectors are enabled ( Yes or No ).
Allow Access to CMC
CLI from iKVM
Displays that CLI access is enabled on the iKVM ( Yes or No ).
Troubleshooting and Recovery 395
Table 12-7. IOM Summary
Item
Location
Present
Name
Fabric
Power Status
Service Tag
Description
Displays the slot occupied by the IOMs. Six slots are identified by group name (A, B, or C) and slot number
(1 or 2). Slot names: A-1 , A-2 , B-1 , B-2 , C-1 , or C-2 .
Displays whether the IOM is present ( Yes or No ).
Displays the name of the IOM.
Displays the type of fabric.
Displays the power status of the IOM: On , Off , or N/A
(Absent).
Displays the service tag of the IOM. The service tag a unique identifier provided by the manufacturer for support and maintenance.
Using RACADM
1 Open a serial/Telnet/SSH text console to CMC and log in.
2 To view chassis and CMC summaries, type: racadm getsysinfo
3 To view the iKVM summary, type: racadm getkvminfo
4 To view the IOM summary, type: racadm getioinfo
396 Troubleshooting and Recovery
Viewing Chassis and Component Health Status
Using the Web Interface
To view chassis and component health summaries:
1 Log in to the CMC Web interface.
2 Select Chassis in the system tree. The Chassis Health page displays.
The Chassis Graphics section provides a graphical view of the front and rear of the chassis. This graphical representation provides a visual overview of the components installed within the chassis and its corresponding status.
Each graphic displays a real-time representation of the installed components. The component state is indicated by the overlay of the component subgraphic.
• No overlay - the component is present, powered on and communicating with CMC; there is no indication of an adverse condition.
• Amber caution sign - indicates that only warning alerts have been issued and that corrective action must be taken.
• Red X - indicates at least one failure condition is present. This means that CMC can still communicate with the component and that the health status is reported as critical.
• Grayed Out - indicates that the component is present and not powered on. It is not communicating with CMC and there is no indication of an adverse condition.
All components display a corresponding text hint or screen tip when the mouse is placed over the component subgraphic. Component status is dynamically updated, and the component subgraphic colors and text hints are automatically changed to reflect the current state.
Clicking on the component subgraphic selects that component's information and Quick Links for display below the chassis graphics.
The CMC Hardware Log section provides the latest 10 entries of the
CMC Hardware Log for reference (see Viewing the Hardware Log).
Troubleshooting and Recovery 397
398
Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type: racadm getmodinfo
Viewing the Event Logs
The Hardware Log and CMC Log pages display system-critical events that occur on the managed system.
Viewing the Hardware Log
CMC generates a hardware log of events that occur on the chassis. You can view the hardware log using the Web interface and remote RACADM.
NOTE: To clear the hardware log, you must have Clear Logs Administrator privilege.
NOTE: You can configure CMC to send e-mail or SNMP traps when specific events
occur. For information on configuring CMC to send alerts, see "Configuring SNMP
Alerts" on page 379 and "Configuring E-mail Alerts" on page 385.
Examples of hardware log entries critical System Software event: redundancy lost
Wed May 09 15:26:28 2007 normal System Software event: log cleared was asserted
Wed May 09 16:06:00 2007 warning System Software event: predictive failure was asserted
Wed May 09 15:26:31 2007 critical System Software event: log full was asserted
Wed May 09 15:47:23 2007 unknown System Software event: unknown event
Using the Web Interface
You can view, save a text file version of, and clear the hardware log in the
CMC Web interface.
Table 12-8 provides descriptions of the information provided on the
Hardware Log page in the CMC Web interface.
Troubleshooting and Recovery
To view the hardware log:
1 Log in to the CMC Web interface.
2 Click Chassis in the system tree.
3 Click the Logs tab.
4 Click the Hardware Log subtab. The Hardware Log page displays.
To save a copy of the hardware log to your managed station or network:
1 Click Save Log .
A dialog box opens.
2 Select a location for a text file of the log.
NOTE: Because the log is saved as a text file, the graphical images used to indicate severity in the user interface do not appear. In the text file, severity is indicated with the words OK, Informational, Unknown, Warning, and Severe.
The date and time entries appear in ascending order. If <SYSTEM BOOT> appears in the Date/Time column, it means that the event occurred during shut down or start up of any of the modules, when no date or time is available.
To clear the hardware log, click Clear Log .
NOTE: CMC creates a new log entry indicating that the log was cleared.
Table 12-8. Hardware Log Information
Item
Severity
Description
OK Indicates a normal event that does not require corrective actions.
Informational Indicates an informational entry on an event in which the Severity status has not changed.
Unknown
Warning
Severe
Indicates a noncritical event for which corrective actions should be taken soon to avoid system failures.
Indicates a critical event requiring immediate corrective actions to avoid system failures.
Indicates a critical event that requires immediate corrective actions to avoid system failures.
Troubleshooting and Recovery 399
400
Table 12-8. Hardware Log Information (continued)
Item
Date/Time
Description
Description
Displays the exact date and time the event occurred (for example,
Wed May 02 16:26:55 2007). If no date/time appears, then the event occurred at System Boot.
Provides a brief description, generated by CMC, of the event (for example, Redundancy lost , Server inserted ).
Using RACADM
1 Open a serial/Telnet/SSH text console to CMC and log in.
2 To view the hardware log, type: racadm getsel
To clear the hardware log, type: racadm clrsel
Viewing the CMC Log
CMC generates a log of chassis-related events.
NOTE: To clear the hardware log, you must have Clear Logs Administrator privilege.
Using the Web Interface
You can view, save a text file version of, and clear the CMC log in the CMC
Web interface.
You can re-sort the log entries by Source, Date/Time, or Description by clicking the column heading. Subsequent clicks on the column headings reverse the sort.
Table 12-9 provides descriptions of the information provided on the
CMC
Log page in the CMC Web interface.
To view the CMC log:
1 Log in to the CMC Web interface.
2 Click Chassis in the system tree.
3 Click the Logs tab.
Troubleshooting and Recovery
4 Click the CMC Log subtab. The CMC Log page displays.
5 To save a copy of the CMC log to your managed station or network, click
Save Log .
A dialog box opens; select a location for a text file of the log.
Table 12-9. CMC Log Information
Command
Source
Date/Time
Description
Result
Displays the interface (such as CMC) that caused the event.
Displays the exact date and time the event occurred (for example,
Wed May 02 16:26:55 2007).
Provides a short description of the action, such as a login or a logout, login failure, or clearing the logs. Descriptions are generated by CMC.
Using RACADM
1 Open a serial/Telnet/SSH text console to CMC and log in.
2 To view the hardware log, type: racadm getraclog
To clear the hardware log, type: racadm clrraclog
Using the Diagnostic Console
The Diagnostic Console page enables an advanced user, or a user under the direction of technical support, to diagnose issues related to the chassis hardware using CLI commands.
NOTE: To modify these settings, you must have Debug Command Administrator privilege.
To access the Diagnostic Console page:
1 Log in to the CMC Web interface.
2 Click Chassis in the system tree.
3 Click the Troubleshooting tab.
4 Click the Diagnostics subtab. The Diagnostic Console page displays.
Troubleshooting and Recovery 401
To execute a diagnostic CLI command, type the command into the Enter
RACADM Command field, and then click Submit to execute the diagnostic command. A diagnostic results page appears.
To return to the Diagnostic Console page, click Go Back to Diagnostic
Console Page or Refresh .
The Diagnostic Console supports the commands listed in Table 12-10 as well
as the RACADM commands.
Table 12-10. Supported Diagnostic Commands
Command Result arp ifconfig netstat
Displays the contents of the address resolution protocol (ARP) table. ARP entries may not be added or deleted.
Displays the contents of the network interface table.
Prints the contents of the routing table.
ping < IP address > Verifies that the destination < IP address > is reachable from
CMC with the current routing-table contents. You must type a destination IP address in the field to the right of this option.
An Internet control message protocol (ICMP) echo packet is sent to the destination IP address based on the current routing-table contents.
gettracelog Displays the trace log (may take a few seconds to display the log). The gettracelog -i command returns the number of records in the trace log.
NOTE: For more information about the gettracelog command, see the gettracelog command section in the Command Line
Reference Guide for iDRAC6 and CMC .
Resetting Components
The Reset Components page allows users to reset the active CMC, or to virtually reseat servers causing them to behave as if they were removed and reinserted. If the chassis has a standby CMC, resetting the active CMC causes a failover and the standby CMC becomes active.
NOTE: To reset components, you must have Debug Command Administrator privilege.
402 Troubleshooting and Recovery
To access the Diagnostic Console page:
1 Log in to the CMC Web interface.
2 Click Chassis in the system tree.
3 Click the Troubleshooting tab.
4 Click the Reset Components subtab. The Reset Components page displays. The CMC Summary section of the Reset Components page displays the following information:
Table 12-11. CMC Summary
Attribute
Health
Date/Time
Description
OK
Informational Displays information about CMC when no change in health status (OK, Warning, Severe) has occurred.
Warning
CMC is present and communicating with its components.
Warning alerts have been issued, and corrective action must be taken.
If corrective actions are not taken, critical or severe failures that can affect the integrity of CMC can occur.
Severe At least one failure alert has been issued.
Severe status represents a CMC system failure, and corrective action must be taken immediately .
Displays the date and time for the CMC using the format MM/DD/YYYY , where MM is the month, DD is the date, and YYYY is the year.
Displays the location of the active CMC.
Active CMC
Location
Redundancy
Mode
Displays Redundant if a standby CMC is present in the chassis, and
No Redundancy if no standby CMC is present in the chassis.
Troubleshooting and Recovery 403
5 The Virtual Reseat Server section of the Reset Components page displays the following information:
Table 12-12. Virtual Reseat Server
Attribute
Slot
Name
Present
Health
Description
Displays the slot occupied by the server in the chassis. Slot names are sequential IDs, from 1 to 16, to help identify the location of the server in the chassis.
Displays the name of the server in each slot.
Displays whether the server is present in the slot ( Yes or No ).
OK
Informational Displays information about the server when there is no change in health status (OK,
Warning, Severe).
Warning
The server is present and communicating with
CMC. In the event of a communication failure between CMC and the server, the CMC cannot obtain or display health status for the server.
Warning alerts have been issued, and corrective action must be taken.
If corrective actions are not taken, critical or severe failures that can affect the integrity of the server can occur.
Severe At least one failure alert has been issued.
Severe status represents a CMC system failure, and corrective action must be taken immediately .
404 Troubleshooting and Recovery
Table 12-12. Virtual Reseat Server
Attribute Description iDRAC Status Displays the status of the server iDRAC embedded management controller:
• N/A - Server is not present, or the chassis is not powered on.
• Ready - iDRAC is ready and operating normally.
• Corrupted - iDRAC firmware is corrupted. Use the iDRAC firmware update utility to repair the firmware.
• Failed - Unable to communicate with iDRAC. Use the Virtual
Reseat check box to clear the error. If this fails, manually remove and replace the server to clear the error.
• FW Update - iDRAC firmware update in progress; allow the update to complete before attempting any action.
• Initializing - iDRAC reset in progress; wait for the controller to complete powering-on before attempting any action.
Power State Displays the server power status:
• N/A - CMC has not determined the power state of the server.
• Off - The server or the chassis is off.
• On - The chassis and server are on.
• Powering On - Temporary state between Off and On. Once the powering on cycle completes, the Power State changes to On.
• Powering Off - Temporary state between On and Off. Once the powering off cycle completes, the Power State changes to Off.
Virtual Reseat Select the check box to virtually reseat that server.
6 To virtual reseat a server, click the check box of the servers to reseat, and then select Apply Selections . This operation causes the servers to behave as if they were removed and reinserted.
7 Select Reset/Failover CMC to cause the active CMC to reset. If a standby
CMC is present and a chassis is fully redundant, a failover occurs causing the standby CMC to become active.
Troubleshooting and Recovery 405
Troubleshooting Network Time Protocol (NTP)
Errors
After configuring CMC to synchronize its clock with a remote time server over the network, it may take 2-3 minutes before a change in the date and time occurs. If after this time there is still no change, it may be necessary to troubleshoot a problem. CMC may not be able to synchronize its clock for a number of reasons:
• There could be a problem with the NTP Server 1, NTP Server 2, and NTP Server 3 settings.
• An invalid host name or IP address may have been accidentally entered.
• There could be a network connectivity problem that prevents CMC from communicating with any of the configured NTP servers.
• There could be a DNS problem, preventing any of the NTP server host names from being resolved.
CMC provides tools to troubleshoot these problems, with the primary source of troubleshooting information being the CMC Trace Log. This log contains an error message for NTP related failures. If CMC is unable to synchronize with any of the remote NTP servers that have been configured, then it derives its timing from the local system clock.
If CMC is synchronized to the local system clock rather than a remote time server, the trace log contains an entry similar to the following:
Jan 8 20:02:40 cmc ntpd[1423]: synchronized to
LOCAL(0), stratum 10
You can also check the ntpd status by typing the following racadm command: racadm getractime –n
406 Troubleshooting and Recovery
If an ‘*’ is not displayed against one of the configured servers, something may not be set up properly. The output of the above command also contains detailed NTP statistics that may be useful in debugging why the server does not synchronize. If you attempt to configure an NTP server that is Windows based, it may help to increase the MaxDist parameter for ntpd. Before changing this parameter, read and understand all implications of doing so, especially since the default setting should be large enough to work with most
NTP servers. To modify the parameter type the following command: racadm config –g cfgRemoteHosts –o cfgRhostsNtpMaxDist 32
After making the change, restart the ntpd by disabling NTP, waiting 5-10 seconds, then enabling NTP again.
NOTE: NTP may take an additional 3 minutes to try and synchronize again.
To disable NTP, type: racadm config –g cfgRemoteHosts –o cfgRhostsNtpEnable 0
To enable NTP, type : racadm config –g cfgRemoteHosts –o cfgRhostsNtpEnable 1
If the NTP servers are configured correctly and this entry is present in the trace log, then this confirms that CMC is unable to synchronize with any of the configured NTP servers.
There may be other NTP related trace log entries to assist in your troubleshooting effort. If it is a NTP server IP address misconfiguration problem, you may see an entry similar to the following:
Jan 8 19:59:24 cmc ntpd[1423]: Cannot find existing interface for address 1.2.3.4 Jan 8 19:59:24 cmc ntpd[1423]: configuration of 1.2.3.4 failed
If an NTP server setting has been configured with an invalid host name, you may see a trace log entry as follows:
Aug 21 14:34:27 cmc ntpd_initres[1298]: host name not found: blabla Aug 21 14:34:27 cmc ntpd_initres[1298]: couldn't resolve `blabla', giving up on it
See "Using the Diagnostic Console" on page 401 for information on how to
enter the gettracelog command to review the trace log using the CMC
GUI.
Troubleshooting and Recovery 407
Interpreting LED Colors and Blinking Patterns
The LEDs on the chassis provide information by color and blinking/not blinking:
• Steadily glowing, green LEDs indicate that the component is powered on.
If the green LED is blinking, it indicates a critical but routine event, such as a firmware upload, during which the unit is not operational.
It does not indicate a fault.
• A blinking amber LED on a module indicates a fault on that module.
• Blue, blinking LEDs are configurable by the user and used for
identification (see "Configuring LEDs to Identify Components on the
Table 12-13. LED Color and Blinking Patterns
Component
CMC iKVM
LED Color, Blinking Pattern
Green, glowing steadily
Green, blinking
Green, dark
Blue, glowing steadily
Blue, blinking
Amber, glowing steadily
Amber, blinking
Blue, dark
Green, glowing steadily
Green, blinking
Green, dark
Amber, glowing steadily
Amber, blinking
Amber, dark
Meaning
Powered on
Firmware is being uploaded
Powered off
Active
User-enabled module identifier
Not used
Fault
Standby
Powered on
Firmware is being uploaded
Powered off
Not used
Fault
No fault
408 Troubleshooting and Recovery
Table 12-13. LED Color and Blinking Patterns (continued)
Component
Server
IOM
(Common)
IOM (Pass through)
LED Color, Blinking Pattern
Green, glowing steadily
Green, blinking
Green, dark
Blue, glowing steadily
Blue, blinking
Amber, glowing steadily
Amber, blinking
Blue, dark
Green, glowing steadily
Green, blinking
Green, dark
Blue, glowing steadily
Blue, blinking
Amber, glowing steadily
Amber, blinking
Blue, dark
Green, glowing steadily
Green, blinking
Green, dark
Blue, glowing steadily
Blue, blinking
Amber, glowing steadily
Amber, blinking
Blue, dark
Meaning
Powered on
Firmware is being uploaded
Powered off
Normal
User-enabled module identifier
Not used
Fault
No fault
Powered on
Firmware is being uploaded
Powered off
Normal/stack master
User-enabled module identifier
Not used
Fault
No fault/stack slave
Powered on
Not used
Powered off
Normal
User-enabled module identifier
Not used
Fault
No fault
Troubleshooting and Recovery 409
Table 12-13. LED Color and Blinking Patterns (continued)
Component
Fan
PSU
LED Color, Blinking Pattern Meaning
Green, glowing steadily
Green, blinking
Green, dark
Amber, glowing steadily
Fan working
Not used
Powered off
Fan type not recognized, update
CMC firmware
Amber, blinking
Amber, dark
Fan fault; tachometer out of range
Not used
(Oval) Green, glowing steadily AC OK
(Oval) Green, blinking Not used
(Oval) Green, dark
Amber, glowing steadily
Amber, blinking
Amber, dark
(Circle) Green, glowing steadily
(Circle) Green, dark
AC Not OK
Not used
Fault
No fault
DC OK
DC Not OK
Troubleshooting a Non-responsive CMC
NOTE: It is not possible to log in to the standby CMC using a serial console.
If you cannot log in to CMC using any of the interfaces (the Web interface,
Telnet, SSH, remote RACADM, or serial), you can verify the
CMC functionality by observing the LEDs on CMC, obtaining recovery information using the DB-9 serial port, or recovering the
CMC firmware image.
410 Troubleshooting and Recovery
Observing the LEDs to Isolate the Problem
Facing the front of CMC as it is installed in the chassis, you see two LEDs on the left side of the card.
Top LED — The top green LED indicates power. If it is NOT on:
1 Verify that you have AC present to at least one power supply.
2 Verify that the CMC card is seated properly. You can release/pull on the ejector handle, remove CMC, reinstall CMC making sure the board is inserted all the way and the latch closes correctly.
Bottom LED — The bottom LED is multi-colored. When CMC is active and running, and there are no problems, the bottom LED is blue. If it is amber, a fault was detected. The fault could be caused by any of the following three events:
• A core failure. In this case, the CMC board must be replaced.
• A self-test failure. In this case, the CMC board must be replaced.
• An image corruption. In this case, you can recover CMC by uploading the
CMC firmware image.
NOTE: A normal CMC boot/reset takes over a minute to fully boot into its OS and be available for login. The blue LED is enabled on the active CMC. In a redundant, two-CMC configuration, only the top green LED is enabled on the standby CMC.
Obtain Recovery Information From the DB-9 Serial Port
If the bottom LED is amber, recovery information should be available from the DB-9 serial port located on the front of CMC.
To obtain recovery information:
1 Install a NULL modem cable between CMC and a client machine.
2 Open a terminal emulator of your choice (such as HyperTerminal or
Minicom). Set up: 8 bits, no parity, no flow control, baud rate 115200.
A core memory failure displays an error message every 5 seconds.
3 Press <Enter>. If a recovery prompt appears, additional information is available. The prompt indicates the CMC slot number and failure type.
To display failure reason and syntax for a few commands, type recover
Troubleshooting and Recovery 411
and then press <Enter>. Sample prompts: recover1[self test] CMC 1 self test failure recover2[Bad FW images] CMC2 has corrupted images
• If the prompt indicates a self test failure, there are no serviceable components on CMC. CMC is bad and must returned to Dell.
• If the prompt indicates Bad FW Images , then follow the steps in
"Recovering the Firmware Image" on page 412 to fix the problem.
Recovering the Firmware Image
CMC enters recover mode when a normal CMC OS boot is not possible. In recover mode, a small subset of commands are available that allow you to reprogram the flash devices by uploading the firmware update file, firmimg.cmc
. This is the same firmware image file used for normal firmware updates. The recovery process displays its current activity and boots to the
CMC OS upon completion.
When you type recover and then press <Enter> at the recovery prompt, the recover reason and available sub-commands display. An example recover sequence may be: recover getniccfg recover setniccfg 192.168.0.120 255.255.255.0
192.168.0.1
recover ping 192.168.0.100
recover fwupdate -g -a 192.168.0.100
NOTE: Connect the network cable to the left most RJ45
NOTE: In recover mode, you cannot ping CMC normally because there is no active network stack. The recover ping <TFTP server IP> command allows you to ping to the TFTP server to verify the LAN connection. You may need to use the recover reset command after setniccfg on some systems.
412 Troubleshooting and Recovery
Troubleshooting Network Problems
The internal CMC trace log allows you to debug CMC alerting and networking. You can access the trace log using the CMC Web interface
(see "Using the Diagnostic Console") or RACADM (see "Using the
RACADM Command Line Interface" and the
gettracelog command section in the Command Line Reference Guide for iDRAC6 and CMC .
The trace log tracks the following information:
• DHCP — Traces packets sent to and received from a DHCP server.
• DDNS — Traces dynamic DNS update requests and responses.
• Configuration changes to the network interfaces.
The trace log may also contain CMC firmware-specific error codes that are related to the internal CMC firmware, not the managed system’s operating system.
Resetting Forgotten Administrator Password
CAUTION: Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
To perform management actions, a user with Administrator privileges is required. The CMC software has a user account password protection security feature that may be disabled if the administrator account password is forgotten. If the administrator account password is forgotten, it can be recovered using the PASSWORD_RSET jumper on the CMC board.
The CMC board has a two-pin password reset connector as shown in
Figure 12-1. If a jumper is installed in the reset connector, the default
administrator account and password is enabled and set to the default values of username: root and password: calvin . The administrator account is reset regardless if the account has been removed, or if the password was changed.
NOTE: Ensure the CMC module is in a passive state before you begin.
Troubleshooting and Recovery 413
To perform management actions, a user with Administrator privileges is required. If the administrator account password is forgotten, it can be reset using the PASSWORD_RST jumper on the CMC board.
The PASSWORD_RST jumper uses a two-pin connector as shown in
While the PASSWORD_RST jumper is installed, the default administrator account and password is enabled and set to the following default values: username: root password: calvin
The administrator account is temporarily reset regardless if the administrator account was removed, or if the password was changed.
NOTE: When the PASSWORD_RST jumper is installed, a default serial console configuration is used (rather than configuration property values), as follows: cfgSerialBaudRate=115200 cfgSerialConsoleEnable=1 cfgSerialConsoleQuitKey=^\ cfgSerialConsoleIdleTimeout=0 cfgSerialConsoleNoAuth=0 cfgSerialConsoleCommand="" cfgSerialConsoleColumns=0
1 Press in the CMC release latch on the handle and move the handle away from the module front panel. Slide the CMC module out of the enclosure.
NOTE: Electrostatic discharge (ESD) events can damage CMC. Under certain conditions, ESD may build up on your body or an object, and then discharge into your CMC. To prevent ESD damage, you must take precautions to discharge static electricity from your body while handling and accessing CMC outside the Chassis.
2 Remove the jumper plug from the password reset connector, and insert a
2-pin jumper to enable the default administrator account. See Figure 12-1
to locate the password jumper on the CMC board.
414 Troubleshooting and Recovery
Figure 12-1. Password Reset Jumper Location
PASSWORD_RSET
Table 12-14. CMC Password Jumper Settings
PASSWORD_RSET (default) The password reset feature is disabled.
The password reset feature is enabled.
3 Slide the CMC module into the enclosure. Reattach any cables that were disconnected.
NOTE: Ensure that the CMC module becomes the active CMC, and remains the active CMC until the remaining steps are completed.
Troubleshooting and Recovery 415
4 If the jumpered CMC module is the only CMC, then simply wait for it to finish rebooting. If you have redundant CMCs in your chassis, then initiate a changeover to make the jumpered CMC module active. On the
GUI interface: a b
Navigate to the Chassis page, click the Power tab ï‚® Control subtab.
Select the Reset CMC (warm boot) button. c Click Apply .
CMC automatically fails over to the redundant module, and that module now becomes active.
5 Log into the active CMC using the default administrator username: root and password: calvin, and restore any necessary user account settings. The existing accounts and passwords are not disabled and are still active.
6 Perform any needed management actions, including creating a new administrator password in place of the forgotten one.
7 Remove the 2-pin PASSWORD_RST jumper and replace the jumper plug. a b c
Press in the CMC release latch on the handle and move the handle away from the module front panel. Slide the CMC module out of the enclosure.
Remove the 2-pin jumper and replace the jumper plug.
Slide the CMC module into the enclosure. Reattach any cables that
were disconnected. Repeat step 4 to make the unjumpered CMC
module the active CMC.
Troubleshooting Alerting
Use the CMC log and the trace log to troubleshoot CMC alerts. The success or failure of each e-mail and/or SNMP trap delivery attempt is logged into the
CMC log. Additional information describing the particular error is logged in the trace log. However, since SNMP does not confirm delivery of traps, use a network analyzer or a tool such as Microsoft’s snmputil to trace the packets on the managed system.
You can configure SNMP alerts using the Web interface. For information, see
416 Troubleshooting and Recovery
13
Diagnostics
The LCD panel helps you to diagnose problems with any server or module in the chassis. If there is a problem or fault with the chassis or any server or other module in the chassis, the LCD panel status indicator blinks amber. On the
Main Menu an icon with an amber background displays next to the menu item—Server or Enclosure—that leads to the faulty server or module.
By following the amber icons down through the LCD menu system, you can display the status screen and error messages for the item that has the problem.
Error messages on the LCD panel can be removed by removing the module or server that is the cause of the problem or for server errors, use the iDRAC
Web interface or command line interface to clear the server’s System Event
Log (SEL) to remove the server errors form the LCD.
Using the LCD Panel Interface
You can use the LCD panel to perform configuration and diagnostics, and to obtain status information about the chassis and its contents.
LCD Navigation
Use the buttons to the right of the LCD screen to operate the LCD panel.
The up, down, left, and right arrow buttons change the selected menu items or icons on the screen. The selected item is shown with a light blue background or border.
The center button activates the selected item.
When messages displayed on the LCD screen are longer than what fits on the screen, use the left and right arrow buttons to scroll the text left and right.
The icons described in Table 13-1 are used in navigating between LCD
screens:
Diagnostics 417
Table 13-1. LCD Panel Navigational Icons
Icon
Normal or
Icon
Highlighted
Icon Name and Description
Back . Highlight and press the center button to return to the previous screen.
Accept/Yes . Highlight and press the center button to accept a change and return to the previous screen.
Skip/Next . Highlight and press the center button to skip any changes and go to the next screen.
No . Highlight and press the center button to answer "No" to a question and go to the next screen.
Rotate . Highlight and press the center button to switch between the front and rear graphical views of the chassis.
NOTE: The amber background indicates that the opposite view has errors.
Component Identify. Blinks the blue LED on a component.
NOTE: There is a blinking blue rectangle around this icon when Component Identify is enabled.
Main Menu
From the Main menu you can navigate to one of the following screens:
• LCD Setup Menu — select the language to use and the LCD screen that displays when no one is using the LCD.
• Server — displays status information for servers.
• Enclosure — displays status information for the chassis.
1 Use the up and down arrow buttons to highlight an item.
2 Press the center button to activate your selection.
418 Diagnostics
LCD Setup Menu
The LCD Setup menu displays a menu of items that can be configured:
• Language Setup — choose the language you want to use for LCD screen text and messages.
• Default Screen — choose the screen that displays when there is no activity on the LCD panel.
1 Use the up and down arrow buttons to highlight an item in the menu or highlight the Back icon if you want to return to the Main menu.
2 Press the center button to activate your selection.
Language Setup Screen
The Language Setup screen allows you to select the language used for LCD panel messages. The currently active language is highlighted with a light blue background.
1 Use the up, down, left, and right arrow buttons to highlight the desired language.
2 Press the center button. The Accept icon appears and is highlighted.
3 Press the center button to confirm the change. The LCD Setup menu is displayed.
Default Screen
The Default Screen allows you to change the screen that the LCD panel displays when there is no activity at the panel. The factory default screen is the Main Menu . You can choose from the following screens to display:
• Main Menu
• Server Status (front graphical view of the chassis)
• Module Status (rear graphical view of the chassis)
• Custom (Dell logo with chassis name)
Diagnostics 419
The currently active default screen is highlighted in light blue.
1 Use the up and down arrow buttons to highlight the screen you want to set to the default.
2 Press the center button. The Accept icon is highlighted.
3 Press the center button again to confirm the change. The Default Screen is displayed.
Graphical Server Status Screen
The Graphical Server Status screen displays icons for each server installed in the chassis and indicates the general health status for each server. The server health is indicated by the color of the server icon:
• Gray — server is off with no errors
• Green — server is on with no errors
• Yellow — server has one or more non-critical errors
• Red — server has one or more critical errors
• Black — server is not present
A blinking light blue rectangle around a server icon indicates that the server is highlighted.
To view the Graphical Module Status screen:
1 Highlight the rotate icon.
2 Press the center button.
To view the status screen for a server:
1 Use the arrow buttons to highlight the desired server.
2 Press the center button. The Server Status screen displays.
To return to the Main Menu:
1 Use the arrow buttons to highlight the Back icon.
2 Press the center button.
420 Diagnostics
Graphical Module Status Screen
The Graphical Module Status screen displays all modules installed in the rear of the chassis and provides summary health information for each module.
Module health is indicated by the color of each module icon as follows:
• Gray — module is off or on standby with no errors
• Green — module is on with no errors
• Yellow — module has one or more non-critical errors
• Red — server has one or more critical errors
• Black — module is not present
A blinking light blue rectangle around a module icon indicates that the module is highlighted.
To view the Gra phical Server Status screen:
1 Highlight the rotate icon.
2 Press the center button.
To view the status screen for a module:
1 Use the up, down, left, and right arrow buttons to highlight the desired module.
2 Press the center button. The Module Status screen displays.
To return to the Main Menu :
1 Use the arrow buttons to highlight the Back icon.
2 Press the center button. The Main Menu displays.
Enclosure Menu Screen
From this screen you can navigate to the following screens:
• Module Status screen
• Enclosure Status screen
• IP Summary screen
• Main Menu
1 Use the navigation buttons to highlight the desired item. (Highlight the
Back icon to return to the Main Menu .)
2 Press the center button. The selected screen displays.
Diagnostics 421
Module Status Screen
The Module Status screen displays information and error messages about a
module. See "LCD Module and Server Status Information" on page 433 and
"LCD Error Messages" on page 426 for messages that can appear on this
screen.
Use the up and down arrow keys to move through messages. Use the left and right arrow keys to scroll messages that do not fit on the screen.
Highlight the Back icon and press the center button to return to the
Graphical Module Status screen.
Enclosure Status Screen
The Enclosure Status screen displays information and error messages about
the enclosure. See "LCD Error Messages" on page 426 for messages that can
appear on this screen.
Use the up and down arrow keys to move through messages. Use the left and right arrow keys to scroll messages that do not fit on the screen.
Highlight the Back icon and press the center button to return to the
Enclosure Status screen.
IP Summary Screen
The IP Summary screen shows IP information for CMC and iDRAC of each installed server.
Use the up and down arrow buttons to scroll through the list. Use the left and right arrow buttons to scroll selected messages that are longer than the screen.
Use the up and down arrow buttons to select the Back icon and press the center button to return to the Enclosure menu.
422 Diagnostics
Diagnostics
The LCD panel helps you to diagnose problems with any server or module in the chassis. If there is a problem or fault with the chassis or any server or other module in the chassis, the LCD panel status indicator blinks amber. On the
Main Menu a blinking icon with an amber background displays next to the menu item—Server or Enclosure—that leads to the faulty server or module.
By following the blinking amber icons down through the LCD menu system, you can display the status screen and error messages for the item that has the problem.
Error messages on the LCD panel can be removed by removing the module or server that is the cause of the problem or by clearing the hardware log for the module or server. For server errors, use the iDRAC Web interface or command line interface to clear the server’s System Event Log (SEL). For chassis errors, use the CMC Web interface or command line interface to clear the hardware log.
LCD Hardware Troubleshooting
If you are experiencing issues with the LCD in relation to your use of CMC, use the following hardware troubleshooting items to determine if there is an
LCD hardware or connection issue.
Diagnostics 423
Figure 13-1. Removing and Installing the LCD Module
4
3
5
2
1
1
3
5 cable cover ribbon cable screws (2)
2
4
LCD module hinges (2)
424 Diagnostics
Table 13-2. LCD Hardware Trouble Shooting Items
Symptom Issue Recovery Action
Alert screen message CMC
Not Responding and
LED is blinking amber.
Loss of communication from CMC to the LCD front panel.
Check that CMC is booting; then, reset CMC using GUI or RACADM commands.
Alert screen message CMC
Not Responding and
LED is solid amber or is off.
LCD module communications is stuck during a CMC fail-over or reboots.
Review the hardware log using the GUI or RACADM commands. Look for a message that states: Can not communicate with
LCD controller.
Reseat the LCD module ribbon cable.
Screen text is scrambled. Defective LCD screen.
LED and LCD is off.
LCD screen message
CMC Found.
No
The LCD cable is not connected properly or is faulty; or the LCD module is faulty.
Replace the LCD module.
Review the hardware log using the GUI or RACADM commands. Look for a message that states:
• The LCD module cable is not connected, or is improperly connected.
• The control panel cable is not connected, or is improperly connected .
Reseat cables.
No CMC is present in the chassis.
Insert a CMC into the chassis or reseat existing
CMC if present.
Diagnostics 425
426
Front Panel LCD Messages
This section contains two subsections that list error and status information that is displayed on the front panel LCD.
Error messages on the LCD have a format that is similar to the System Event
Log (SEL) viewed from the CLI or Web interface. The format is as follows:
< Severity > < Sensor Name>: <Sensor Type> sensor for
<Entity>, <Description of event>
The tables in the error section list the error and warning messages that are displayed on the various LCD screens and the possible cause of the message.
Text enclosed in angled brackets (< >) indicates that the text may vary.
Status information on the LCD includes descriptive information about the modules in the chassis. The tables in this section describe the information that is displayed for each component.
LCD Error Messages
Table 13-3. CMC Status Screens
Severity
Critical
Critical
Warning
Warning
Warning
Message
The CMC <number> battery failed.
CMC <number> LAN heartbeat was lost.
A firmware or software incompatibility detected between iDRAC in slot <number> and
CMC.
A firmware or software incompatibility detected between system BIOS in slot <number> and CMC.
A firmware or software incompatibility detected between
CMC 1 and CMC 2.
Cause
CMC CMOS battery is missing or has no voltage.
The CMC NIC connection has been removed or is not connected.
Firmware between the two devices does not match in order to support one or more features.
Firmware between the two devices does not match in order to support one or more features.
Firmware between the two devices does not match in order to support one or more features.
Diagnostics
Table 13-4. Enclosure/Chassis Status Screen
Severity
Critical
Warning
Critical
Critical
Warning
Critical
Critical
Critical
Warning
Warning
Message Cause
Fan <number> is removed.
Power supply redundancy is degraded.
This fan is required for proper cooling of the enclosure/chassis.
One or more PSU have failed or removed and the system can no longer support full PSU redundancy.
Power supply redundancy is lost.
One or more PSU have failed or removed and the system is no longer redundant.
The power supplies are not redundant. Insufficient resources to maintain normal operations.
One or more PSU have failed or removed and the system lacks sufficient power to maintain normal operations. This could cause servers to power down.
The control panel ambient temperature is greater than the upper warning threshold.
The control panel ambient temperature is greater than the upper warning threshold.
CMC redundancy is lost.
All event logging is disabled.
Chassis/Enclosure intake temperature exceeded the warning threshold.
Chassis/Enclosure intake temperature exceeded the warning threshold.
CMC no longer redundant. This happens if the standby CMC is removed.
The Chassis/Enclosure can not store events to the logs. This usually indicates a problem with the control panel or control panel cable.
Log is full.
Log is almost full.
Chassis has detected that only one more entry can be added to the
CEL (hardware log) before it is full.
Chassis event log is 75% full.
Diagnostics 427
Table 13-5. Fan Status Screens
Severity
Critical
Critical
Message Cause
Fan <number> RPM is operating less than the lower critical threshold.
The speed of the specified fan is not sufficient to provide enough cooling to the system.
Fan <number> RPM is operating greater than the upper critical threshold.
The speed of the specified fan is to high, usually due to a broken fan blade.
Table 13-6. IOM Status Screens
Severity
Warning
Warning
Critical
Message Cause
A fabric mismatch detected on I/O module <number>.
The IO module fabric does not match that of the server or the redundant I/O module.
A link tuning failure detected on
I/O module <number>.
The IO module could not be set to correctly use the NIC on one or more servers.
A failure is detected on I/O module
<number>.
The I/O module has a fault. The same error can also happen if the
I/O module is thermal-tripped.
Table 13-7. iKVM Status Screen
Severity
Warning
Critical
Critical
Non-
Recoverable
Message
Console is not available for Local
KVM.
Local KVM can not detect any hosts.
OSCAR, on screen display is not functional for the Local KVM.
Local KVM is not functional, and is powered off.
Cause
Minor failure, such as corrupted firmware.
USB host enumeration failure.
OSCAR failure.
Serial RIP failure or USB host chip failure.
428 Diagnostics
Table 13-8. PSU Status Screens
Severity
Critical
Critical
Warning
Message Cause
Power supply <number> failed.
The PSU has failed.
The power input for power supply
<number> is lost.
Loss of AC power or AC cord unplugged.
Power supply <number> is operating at 110 volts, and could cause a circuit breaker fault.
Power supply is plug into a 110 volt source.
Table 13-9. Server Status Screen
Severity
Warning
Critical
Warning
Critical
Critical.
Critical
Warning
Critical
Message Cause
The system board ambient temperature is less than the lower warning threshold.
The system board ambient temperature is less than the lower critical threshold.
The system board ambient temperature is greater than the upper warning threshold.
The system board ambient temperature is greater than the upper critical threshold.
Server temperature is getting cool.
Server temperature is getting cold.
Server temperature is getting warm.
Server temperature is getting too hot.
The system board Current Latch current is outside of the allowable range
Current crossed a failing threshold.
The system board battery failed.
CMOS battery is not present or has no voltage.
The storage battery is low.
The storage battery failed.
ROMB battery is low.
CMOS battery is not present or has no voltage.
Diagnostics 429
Table 13-9. Server Status Screen (continued)
Severity
Critical
Critical
Critical
Critical
Critical
Critical
Critical
Critical
Critical
Critical
Critical
Critical
Message Cause
The CPU <number> <voltage sensor name > voltage is outside of the allowable range.
The system board <voltage sensor name > voltage is outside of the allowable range.
The mezzanine card <number>
<voltage sensor name > voltage is outside of the allowable range.
The storage <voltage sensor name
> voltage is outside of the allowable range.
CPU <number> has an internal error (IERR).
CPU <number> has a thermal trip (over-temperature) event.
CPU <number> configuration is unsupported.
CPU <number> is absent.
Drive <number> is removed.
Fault detected on Drive
<number>.
CPU failure.
CPU overheated.
Incorrect processor type or in wrong location.
Required CPU is missing or not present.
Mezz B<slot number> Status:
Add-in Card sensor for Mezz
B<slot number>, install error was asserted.
Incorrect Mezzanine card installed for IO fabric.
Mezz C<slot number> Status:
Add-in Card sensor for Mezz
C<slot number>, install error was asserted.
Incorrect Mezzanine card installed for IO fabric.
Storage Drive was removed.
Storage Drive failed.
430 Diagnostics
Table 13-9. Server Status Screen (continued)
Severity
Critical
Critical
Critical
Critical
Critical
Critical
Warning
Warning
Critical
Message
The system board fail-safe voltage is outside of the allowable range.
The watchdog timer expired.
The watchdog timer reset the system.
The watchdog timer powered off the system.
The watchdog timer power cycled the system.
Log is full.
Cause
This event is generated when the system board voltages are not at normal levels.
The iDRAC watchdog timer expires and no action is set.
The iDRAC watchdog detected that the system has crashed (timer expired because no response was received from Host) and the action is set to reboot.
The iDRAC watchdog detected that the system has crashed (timer expired because no response was received from Host) and the action is set to power off.
The iDRAC watchdog detected that the system has crashed (timer expired because no response was received from Host) and the action is set to power cycle.
The SEL device detects that only one entry can be added to the SEL before it is full.
Persistent correctable memory errors detected on a memory device at location <location>.
Persistent correctable memory error rate has increased for a memory device at location
<location>.
Multi-bit memory errors detected on a memory device at location
<location>.
Correctable ECC errors reach a critical rate.
An uncorrectable ECC error was detected.
Diagnostics 431
432
Table 13-9. Server Status Screen (continued)
Severity
Critical
Critical
Critical
Critical
Critical
Critical
Critical
Critical
Non-
Recoverable
Non-
Recoverable
Non-
Recoverable
Non-
Recoverable
Message Cause
An I/O channel check NMI was detected on a component at bus
<number> device <number> function <number>.
An I/O channel check NMI wa detected on a component at slot
<number>.
A critical interrupt is generated in the I/O Channel.
A critical interrupt is generated in the I/O Channel.
A PCI parity error was detected on a component at bus <number> device <number> function
<number>.
Parity error was detected on the
PCI bus.
A PCI parity error was detected on a component at slot <number>.
Parity error was detected on the
PCI bus.
PCI error detected by device.
A PCI system error was detected on a component at bus
<number> device <number> function <number>.
A PCI system error was detected on a component at slot
<number>.
PCI error detected by device.
Persistent correctable memory error logging disabled for a memory device at location
<location>.
All event logging is disabled.
CPU protocol error detected.
Single bit error logging is disable when too many SBE get logged for a memory device.
CPU bus parity error detected.
The processor protocol entered a non-recoverable state.
The processor bus PERR entered a non-recoverable state.
CPU initialization error detected. The processor initialization entered a non-recoverable state.
CPU machine check detected.
The processor machine check entered a non-recoverable state.
Diagnostics
Table 13-9. Server Status Screen (continued)
Severity
Critical
Critical
Critical
Critical
Critical
Critical
Message Cause
Memory redundancy is lost.
A bus fatal error was detected on a component at bus <number> device <number> function
<number>.
Fatal error is detected on the PCIe bus.
A software NMI was detected on a component at bus <number> device <number> function
<number>.
Chip error is detected.
Failed to program virtual MAC address on a component at bus
<number> device <number> function <number>.
Flex address could be programmed for this device.
Device option ROM on mezzanine card <number> failed to support
Link Tuning or FlexAddress.
Option ROM does not support
Flex address or linking tuning.
Failed to get Link Tuning or
FlexAddress data from iDRAC.
NOTE: For information on other server related LCD messages, see "Server User
Guide".
LCD Module and Server Status Information
The tables in this section describe status items that are displayed on the front panel LCD for each type of component in the chassis.
Table 13-10. CMC Status
Item
Example: CMC1,
CMC2
No Errors
Description
Name/Location.
If no error occurs then “No Errors” is displayed, else lists error messages.
Diagnostics 433
Table 13-10. CMC Status (continued)
Item
Firmware Version
Description
Only displays on an active CMC. Displays Standby for the standby CMC.
Displays current IPv4 enabled state only on an active CMC.
IP4 <enabled, disabled>
IP4 Address:
<address, acquiring>
IP6 <enabled, disabled>
IP6 Local Address:
<address>
IP6 Global Address:
<address>
Only displays if IPv4 is enabled only on an active CMC.
Displays current IPv6 enabled state only on an active CMC.
Only displays if IPv6 is enabled only on an active CMC.
Only displays if IPv6 is enabled only on an active CMC.
Table 13-11. Chassis/Enclosure Status
Item Description
User Define Name
Error Messages
Example: “Dell Rack System”. This is settable via CMC CLI or Web GUI.
If no errors occur then No Errors is displayed; otherwise error messages are listed, critical errors first, then warnings.
Model Number Example "PowerEdgeM1000".
Power Consumption Current power consumption in watts.
Peak Power
Minimum Power
Peak power consumed in watts.
Minimum power consumed in watts.
Ambient Temperature Current ambient temperature in degrees Celsius.
Service Tag The factory-assigned service tag.
CMC redundancy mode
Non-Redundant or Redundant.
PSU redundancy mode Non-Redundant, AC Redundant, or DC Redundant.
434 Diagnostics
Table 13-12. Fan Status
Item
Name/Location
Error Messages
RPM
Description
Example: Fan1, Fan2, etc.
If no error then "No Errors" is shown; otherwise error messages are listed, critical errors first, then warnings.
Current fan speed in RPM.
Table 13-13. PSU Status
Item Description
Name/Location
Error Messages
Example: PSU1, PSU2, etc.
If no error then "No Errors" is shown; otherwise error messages are listed, critical errors first, then warnings.
Status Offline, Online, or Standby.
Maximum Wattage Maximum Wattage that PSU can supply to the system.
Table 13-14. IOM Status
Item
Name/Location
Error Messages
Status
Model
Fabric Type
IP address
Service Tag
Description
Example: IOM A1, IOM B1. etc.
If no error then "No Errors" is shown; otherwise error messages are listed, critical errors first, then warnings.
Off or On.
Model of the IOM.
Networking type.
Only shows if IOM is On. This value is zero for a pass through type IOM.
The factory-assigned service tag.
Diagnostics 435
436
Table 13-15. iKVM Status
Item Description
Name
No Error iKVM.
If there are no errors, then No Errors is displayed; otherwise error messages are listed. The critical errors are listed first,
and then the warnings. For more information see "LCD Error
Status Off or On.
Model/Manufacture A description of the iKVM model.
Service Tag
Part Number
The factory-assigned service tag.
The Manufacturer part number.
Firmware Version
Hardware Version iKVM firmware version.
iKVM hardware version.
NOTE: This information is dynamically updated
Table 13-16. Server Status
Item
Example: Server 1, Server 2, etc.
No Errors
Description
Name/Location.
Slot Name
Name
Model Number
If there are no errors, then No Errors is displayed; otherwise error messages are listed. The critical errors are listed first, and then the warnings. For more
information see "LCD Error Messages".
Chassis slot name. For example, SLOT-01.
NOTE: You can set this table through the CMC CLI or
Web GUI.
Name of the server, which the user can set through
Dell OpenManage. The name is displayed only if iDRAC has finished booting, and the server supports this feature, else iDRAC booting messages are displayed.
Displays if iDRAC finished booting.
Diagnostics
Table 13-16. Server Status (continued)
Item Description
Service Tag
BIOS Version
Last POST Code iDRAC Firmware Version
Displays if iDRAC finished booting.
Server BIOS firmware version.
Displays the last server BIOS POST code messages string.
Displays if iDRAC finished booting.
NOTE: iDRAC version 1.01 is displayed as 1.1. There is no iDRAC version 1.10.
IP4 <enabled, disabled>
IP4 Address: <address, acquiring>
IP6 <enabled, disabled>
Displays the current IPv4 enabled state.
Only displays if IPv4 is enabled.
Only displays if iDRAC supports IPv6. Displays current IPv6-enabled state.
IP6 Local Address: <address> Only displays if iDRAC supports IPv6 and IPv6 is enabled.
IP6 Global Address:
<address>
FlexAddress enabled on
Fabrics
Only displays if iDRAC supports IPv6 and IPv6 is enabled.
Only displays if the feature is installed. Lists the fabrics enabled for this server (that is, A, B, C).
Diagnostics 437
The information in Table 13-16 is dynamically updated. If the server does not
support this feature, then the following information does not appear, else
Server Administrator options are as follows:
• Option “None” = No strings must be displayed on the LCD.
• Option “Default” = No Effect.
• Option “Custom” = Allows you to enter a string name for the server.
The information is displayed only if iDRAC has finished booting. For more information on this feature, see " Command Line Reference Guide for iDRAC6 and CMC"
438 Diagnostics
Index
A
Activating FlexAddress Plus, 235
configuring and managing certificates, 163
using with standard schema, 242
adding
alerts
C
Certificate Signing Request
(CSR)
generating a new certificate, 175
certificates
uploading a server certificate, 178
viewing a server certificate, 179
CMC
creating a configuration file, 95
command line console
configuration file
configuring
connect command
CMC command line connection, 61
Index 439
E
Enabling or Disabling DCHP, 82
H
F
firmware
updating, IOM infrastructure device, 193
frequently asked questions
managing and recovering a remote system, 213
I
iDRAC
L
LDC panel
logs
M managed system
accessing through the local serial port, 56
management station
configuring terminal emulation, 59
Microsoft Active Directory, 241
440 Index
N
network properties
configuring manually, 78 configuring using racadm, 78
O
P
password
power budgeting
R
RAC
RACADM
uninstalling from Linux management station, 36
racadm utility
configuring network properties, 78
Red Hat Enterprise Linux
configuring for serial console redirection, 63
remote RACADM
S
Secure Sockets Layer (SSL)
security
using SSL and digital certificates, 173
serial console
server certificate
services
slot names
editing, 124 naming rules, 124
snap-in
installing the Dell extension, 261
Index 441
SNMP alerts
specifications
standard schema
using with Active Directory, 242
T telnet console
U
V
442
W web browser
web interface
Index
advertisement
Key Features
- Comprehensive hardware management for PowerEdge rack servers
- Secure end-to-end management with advanced security features
- Remote management capabilities for in-band and out-of-band access
- User-friendly web interface and industry-standard CLI for easy management
- Support for industry-standard protocols such as SNMP, IPMI, and Redfish
- Integration with Dell OpenManage Enterprise management console for centralized management
Related manuals
Frequently Answers and Questions
What are the benefits of using the Dell Chassis Management Controller?
What are the key features of the Dell Chassis Management Controller?
How do I access the Dell Chassis Management Controller?
What are the security features of the Dell Chassis Management Controller?
Can I use the Dell Chassis Management Controller to manage servers from different manufacturers?
advertisement
Table of contents
- 1 Dell Chassis Management Controller Firmware Version 3.1
- 3 Contents
- 19 1
- 19 Overview
- 19 What’s New For This Release
- 20 CMC Management Features
- 21 Security Features
- 22 Chassis Overview
- 22 Figure 1-1. Dell M1000e Chassis and CMC
- 23 Hardware Specifications
- 23 TCP/IP Ports
- 23 Table 1-1. CMC Server Listening Ports
- 23 Port Number
- 23 Function
- 23 Table 1-2. CMC Client Port
- 23 Port Number
- 23 Function
- 24 Supported Remote Access Connections
- 24 Table 1-3. Supported Remote Access Connections
- 24 Connection
- 24 Features
- 24 Supported Platforms
- 25 Supported Web Browsers
- 25 1 Open the Windows Control Panel.
- 25 2 Double-click the Regional Options icon.
- 25 3 Select the required locale from the Your locale (location) drop-down menu.
- 25 Supported Management Console Applications
- 25 WS-Management Support
- 27 Other Documents You May Need
- 29 2
- 29 Installing and Setting Up the CMC
- 29 Before You Begin
- 29 Installing the CMC Hardware
- 30 Checklist for Integration of a Chassis
- 30 1 Your CMC and the management station where you use your browser must be on the same network, which is called the management network. Cable the CMC Ethernet port labelled GB to management network.
- 30 2 For rack chassis, install the IO modules in the chassis and cable them.
- 30 3 Insert the servers in the chassis.
- 30 4 Connect the chassis to the power source.
- 30 5 Push the Power button provided at the side of the chassis or, power on the chassis from the CMC GUI after completing step 7.
- 30 6 Using the LCD panel on the front of the system, provide the CMC with a static IP address or configure it for DHCP.
- 30 7 Connect to the CMC IP address through the web browser using the default username(root) and password(calvin).
- 30 8 Provide each iDRAC with an IP address in the CMC GUI and enable the LAN and IPMI interface.
- 30 9 Provide each IO module with an IP address in the CMC GUI.
- 30 10 Connect to each iDRAC through the web browser and provide final configuration of iDRAC. Default username is root and password is calvin.
- 30 11 Connect to each IO module through the web browser and provide final configuration of the IO module.
- 30 12 Power on the servers and install the operating system.
- 30 Basic CMC Network Connection
- 31 Daisy-chain CMC Network Connection
- 32 Figure 2-1. Daisy-chained CMC Network Connection
- 33 Figure 2-2. Incorrect Cabling for CMC Network Connection - 2 CMCs
- 33 Figure 2-3. Incorrect Cabling for CMC Network Connection - Single CMC
- 34 Figure 2-4. Incorrect Cabling for CMC Network Connection - 2 CMCs
- 34 1 Connect the GB port of the active CMC in the first chassis to the management network.
- 34 2 Connect the GB port of the active CMC in the second chassis to the STK port of the active CMC in the first chassis.
- 34 3 If you have a third chassis, connect the GB port of its active CMC to the STK port of the active CMC in the second chassis.
- 34 4 If you have a fourth chassis, connect the GB port of its active CMC to the STK port of the third chassis.
- 34 5 If you have redundant CMCs in the chassis, connect them using the same pattern.
- 35 Installing Remote Access Software on a Management Station
- 35 Installing RACADM on a Linux Management Station
- 35 1 Log on as root to the system running a supported Red Hat Enterprise Linux or SUSE Linux Enterprise Server operating system where you want to install the managed system components.
- 35 2 Insert the Dell Systems Management Tools and Documentation DVD into the DVD drive.
- 36 3 To mount the DVD to a required location, use the mount command or a similar command.
- 36 4 Navigate to the SYSMGMT/ManagementStation/linux/rac directory. To install the RAC software, type the following command:
- 36 5 For help on the RACADM command, type racadm help after you run the previous commands. For more information about RACADM, see "Using the RACADM Command Line Interface" on page 69.
- 36 Uninstalling RACADM From a Linux Management Station
- 36 1 Log on as root to the system where you want to uninstall the management station features.
- 36 2 Use the following rpm query command to determine which version of the DRAC Tools is installed:
- 36 3 Verify the package version to be uninstalled and uninstall the feature by using the rpm -e `rpm -qa | grep mgmtst-racadm` command.
- 36 Configuring a Web Browser
- 37 Proxy Server
- 37 Internet Explorer
- 37 1 Start Internet Explorer.
- 37 2 Click ToolsÆ Internet OptionsÆ Connections.
- 37 3 In the Local Area Network (LAN) settings section, click LAN Settings.
- 37 4 In the Proxy server section, click Advanced.
- 37 5 In the Exceptions section, add the addresses for CMCs and iDRACs on the management network to the semicolon-separated list. You can use DNS names and wildcards in your entries.
- 37 Mozilla FireFox
- 37 1 Start Mozilla Firefox.
- 37 2 Click ToolsÆ Options (for Windows) or click EditÆ Preferences (for Linux).
- 38 3 Click Advanced and then click the Network tab.
- 38 4 Click Settings.
- 38 5 Select the Manual Proxy Configuration.
- 38 6 In the No Proxy for field, type the addresses for CMCs and iDRACs on the management network to the comma-separated list. You can use DNS names and wildcards in your entries.
- 38 Microsoft Phishing Filter
- 38 1 Start Internet Explorer.
- 38 2 Click ToolsÆ Phishing Filter, and then click Phishing Filter Settings.
- 38 3 Select the Disable Phishing Filter check box.
- 38 4 Click OK.
- 38 Certificate Revocation List (CRL) Fetching
- 38 1 Start Internet Explorer.
- 38 2 Click ToolsÆ Internet Options, and then click Advanced.
- 38 3 Scroll to the Security section and uncheck Check for publisher’s certificate revocation.
- 38 4 Click OK.
- 39 Downloading Files From CMC With Internet Explorer
- 39 1 Start Internet Explorer.
- 39 2 Click ToolsÆ Internet Options, then click Advanced.
- 39 3 Scroll to the Security section and check Do not save encrypted pages to disk.
- 39 Allow Animations in Internet Explorer
- 39 1 Start Internet Explorer.
- 39 2 Click ToolsÆ Internet Options, then click Advanced.
- 39 3 Scroll to the Multimedia section and check Play animations in web pages.
- 39 Setting Up Initial Access to the CMC
- 40 Configuring the CMC Network
- 41 Configuring Networking Using the LCD Configuration Wizard
- 42 Figure 2-5. LCD Display
- 43 Navigating in the LCD Screen
- 43 Using the LCD Configuration Wizard
- 43 1 If you have not already done so, press the chassis power button to turn it on.
- 43 2 Select your language using the arrow buttons, and then press the center button to select the Accept/Yes and press the center button again.
- 43 3 The Enclosure screen displays with the following question: Configure Enclosure?
- 43 a Press the center button to continue to the CMC Network Settings screen. See step 4.
- 43 b To exit the Configure Enclosure menu, select the NO icon and press the center button. See step 9.
- 44 4 Press the center button to continue to the CMC Network Settings screen.
- 44 5 Select your network speed (10Mbps, 100Mbps, Auto (1 Gbps)) using the down arrow button.
- 44 6 Select the duplex mode (half or full) that matches your network environment.
- 44 7 Select the Internet Protocol (IPv4, IPv6, or both) that you want to use for the CMC.
- 45 8 Select the mode in which you want the CMC to obtain the NIC IP addresses:
- 45 a Set the Static IP Address by using the right or left arrow keys to move between positions, and the up and down arrow keys to select a number for each position. When you have finished setting the Static IP Address, press the center button to continue.
- 45 b Set the subnet mask, and then press the center button.
- 45 c Set the gateway, and then press the center button. The Network Summary screen displays.
- 45 d When you have confirmed the accuracy of the settings you entered, press the center button. The Register DNS? screen appears.
- 45 9 If you selected DHCP in the previous step, go to step 10.
- 46 10 Indicate whether you want to configure iDRAC:
- 46 11 Select the Internet Protocol (IPv4, IPv6, or both) that you want to use for the servers.
- 46 a Set the Static IP Address by using the right or left arrow keys to move between positions, and the up and down arrow keys to s...
- 46 b Set the subnet mask, and then press the center button.
- 46 c Set the gateway, and then press the center button.
- 46 a Select whether to Enable or Disable the IPMI LAN channel. Press the center button to continue.
- 46 b On the iDRAC Configuration screen, to apply all iDRAC network settings to the installed servers, highlight the Accept/Yes icon...
- 47 c On the next iDRAC Configuration screen, to apply all iDRAC network settings to newly installed servers, highlight the Accept/Y...
- 47 12 On the Enclosure screen, to apply all enclosure settings highlight the Accept/Yes icon and press the center button. To not apply the enclosure settings, highlight the No icon and press the center button.
- 47 13 On the IP Summary screen, review the IP addresses you provided to make sure the addresses are accurate. To correct a setting,...
- 48 Accessing the CMC Through a Network
- 48 Table 2-1. CMC Interfaces
- 48 Interface
- 48 Description
- 49 Installing or Updating the CMC Firmware
- 49 Downloading the CMC Firmware
- 50 Updating CMC Firmware Using the Web Interface
- 50 Updating the CMC Firmware Using RACADM
- 51 Configuring CMC Properties
- 51 Configuring Power Budgeting
- 51 Configuring CMC Network Settings
- 52 Adding and Configuring Users
- 52 Adding SNMP and E-mail Alerts
- 52 Configuring Remote Syslog
- 52 1 Log in to the CMC Web interface.
- 52 2 Click the Network tab.
- 52 3 Click the Services subtab. The Services page appears.
- 53 Understanding the Redundant CMC Environment
- 53 About the Standby CMC
- 54 Active CMC Election Process
- 54 Obtaining Health Status of Redundant CMC
- 55 3
- 55 Configuring CMC to Use Command Line Consoles
- 55 Command Line Console Features on the CMC
- 56 Using a Serial, Telnet, or SSH Console
- 56 Table 3-1. CMC Command Line Commands
- 56 Command
- 56 Description
- 56 Using a Telnet Console With the CMC
- 56 Using SSH With the CMC
- 57 Enabling SSH on the CMC
- 57 Changing the SSH Port
- 58 Table 3-2. Cryptography Schemes
- 58 Scheme Type
- 58 Scheme
- 58 Enabling the Front Panel to iKVM Connection
- 59 Configuring Terminal Emulation Software
- 59 Configuring Linux Minicom
- 59 Configuring Minicom Version 2.0
- 59 1 If you do not have a Minicom configuration file, go to the next step.
- 59 2 At the Linux command prompt, type minicom -s.
- 59 3 Select Serial Port Setup and press <Enter>.
- 59 4 Press <a>, and then select the appropriate serial device (for example, /dev/ttyS0).
- 59 5 Press <e>, and then set the Bps/Par/Bits option to 115200 8N1.
- 59 6 Press <f>, and then set Hardware Flow Control to Yes and set Software Flow Control to No.
- 59 7 Select Modem and Dialing and press <Enter>.
- 60 8 In the Modem Dialing and Parameter Setup menu, press <Backspace> to clear the init, reset, connect, and hangup settings so that they are blank, and then press <Enter> to save each blank value.
- 60 9 When all specified fields are clear, press <Enter> to exit the Modem Dialing and Parameter Setup menu.
- 60 10 Select Save setup as config_name and press <Enter>.
- 60 11 Select Exit From Minicom and press <Enter>.
- 60 12 At the command shell prompt, type minicom <Minicom config file name>.
- 60 13 Press <Ctrl+a>, <x>, <Enter> to exit Minicom.
- 60 Required Minicom Settings
- 60 Table 3-3. Minicom Settings
- 60 Setting Description
- 60 Required Setting
- 61 Connecting to Servers or I/O Modules With the Connect Command
- 62 Table 3-4. Mapping I/O Modules to Switches
- 62 Configuring the Managed Server BIOS for Serial Console Redirection
- 63 1 Boot the managed server.
- 63 2 Press <F2> to enter the BIOS setup utility during POST.
- 63 3 Scroll down to Serial Communication and press <Enter>. In the pop-up dialog box, the serial communication list displays these options:
- 63 4 Ensure that On with console redirection via COM1 is enabled.
- 63 5 Enable Redirection After Boot (default value is disabled). This option enables BIOS console redirection across subsequent reboots.
- 63 6 Save the changes and exit.
- 63 7 The managed server reboots.
- 63 Configuring Windows for Serial Console Redirection
- 63 Configuring Linux for Server Serial Console Redirection During Boot
- 63 1 Locate the general setting sections in the file and add the following two new lines:
- 64 2 Append two options to the kernel line:
- 64 3 If the /etc/grub.conf contains a splashimage directive, comment it out.
- 65 Configuring Linux for Server Serial Console Redirection After Boot
- 69 4
- 69 Using the RACADM Command Line Interface
- 69 Using a Serial, Telnet, or SSH Console
- 70 Logging in to the CMC
- 70 1 Connect to the CMC using your management station terminal emulation software.
- 70 2 Type your CMC user name and password, and then press <Enter>.
- 70 Starting a Text Console
- 70 Using RACADM
- 71 RACADM Subcommands
- 71 Table 4-1. RACADM Subcommands
- 71 Command
- 71 Description
- 74 Accessing RACADM Remotely
- 74 Table 4-2. Remote RACADM Subcommand Options
- 74 Option
- 74 Description
- 76 Enabling and Disabling the RACADM Remote Capability
- 76 Using RACADM Remotely
- 77 RACADM Error Messages
- 78 Using RACADM to Configure the CMC
- 78 Configuring CMC Network Properties
- 78 Setting Up Initial Access to the CMC
- 79 Viewing Current IPv4 Network Settings
- 79 Viewing Current IPv6 Network Settings
- 79 Viewing Current Network Settings
- 80 Configuring the Network LAN Settings
- 80 Enabling the CMC Network Interface
- 82 Enabling or Disabling DHCP for the CMC Network Interface Address
- 82 Enabling or Disabling DHCP for DNS IP Addresses
- 82 Setting Static DNS IP addresses
- 83 Configuring DNS Settings (IPv4 and IPv6)
- 83 Configuring Auto Negotiation, Duplex Mode, and Network Speed (IPv4 and IPv6)
- 84 Setting up the CMC VLAN (IPv4 and IPv6)
- 84 1 Enable the VLAN capabilities of the external chassis management network:
- 84 2 Specify the VLAN ID for the external chassis management network:
- 84 3 Then, specify the VLAN priority for the external chassis management network:
- 85 Removing the CMC VLAN
- 85 Setting up a Server VLAN
- 86 Removing a Server VLAN
- 86 Setting the Maximum Transmission Unit (MTU) (IPv4 and IPv6)
- 86 Setting the SMTP Server IP Address (IPv4 and IPv6)
- 86 Configuring the Network Security Settings (IPv4 Only)
- 87 Enabling IP Range Checking (IPv4 Only)
- 87 Using RACADM to Configure Users
- 87 Before You Begin
- 88 Adding a CMC User
- 88 1 Set the user name.
- 88 2 Set the password.
- 88 3 Set user privileges. For information about user privileges, see Table 5-40, and Table 5-41 in the database property chapter of the Command Line Reference Guide for iDRAC6 and CMC.
- 88 4 Enable the user.
- 88 Example
- 89 Using RACADM to Configure Public Key Authentication over SSH
- 89 Before You Begin
- 90 Generating Public Keys for Windows
- 90 1 Start the application and select SSH-2 RSA or SSH-2 DSA for the type of key to generate (SSH-1 is not supported).
- 90 2 Enter the number of bits for the key. The number should be between 768 and 4096.
- 90 3 Click Generate and move the mouse in the window as directed.
- 90 4 You have two options for using the public key:
- 91 Generating Public Keys for Linux
- 91 RACADM Syntax Notes for CMC
- 91 Viewing the Public Keys
- 92 Adding the Public Keys
- 92 Deleting the Public Keys
- 92 Logging in Using Public Key Authentication
- 93 Enabling a CMC User With Permissions
- 93 Disabling a CMC User
- 94 Configuring SNMP and E-mail Alerting
- 94 Configuring Multiple CMCs in Multiple Chassis
- 94 1 Use RACADM to query the target CMC that contains the desired configuration.
- 94 2 Open a Telnet/SSH text console to the CMC, log in, and type:
- 95 3 Modify the configuration file using a plain-text editor (optional). Any special formatting characters in the configuration file may corrupt the RACADM database.
- 95 4 Use the newly created configuration file to modify a target CMC.
- 95 5 Reset the target CMC that was configured. At the command prompt, type:
- 95 Creating a CMC Configuration File
- 97 Parsing Rules
- 99 Modifying the CMC IP Address
- 100 Using RACADM to Configure Properties on iDRAC
- 101 Troubleshooting
- 101 Table 4-3. Using Serial/ RACADM Commands: Frequently Asked Questions
- 101 Question
- 101 Answer
- 103 5
- 103 Using the CMC Web Interface
- 103 Accessing the CMC Web Interface
- 103 1 Open a supported Web browser window.
- 103 2 Type the following URL in the Address field, and then press <Enter>:
- 104 1 Open a supported Web browser window.
- 104 2 Type the following URL in the Address field, and then press <Enter>:
- 104 Logging In
- 105 1 In the Username field, type your user name:
- 105 2 In the Password field, type your CMC user password or Active Directory user password.
- 105 3 Optionally, select a session timeout. This is the amount of time you can stay logged in with no activity before you are automatically logged out. The default value is the Web Service Idle Timeout. See Configuring Services for more details.
- 105 4 Click OK or press <Enter>.
- 105 Logging Out
- 105 Configuring Basic CMC Settings
- 105 Setting the Chassis Name
- 106 1 Log in to the CMC Web interface. The Chassis Health page displays.
- 106 2 Click the Setup tab. The General Chassis Settings page displays.
- 106 3 Type the new name in the Chassis Name field, and then click Apply.
- 106 Setting the Date and Time on CMC
- 106 1 Log in to the CMC Web interface. The Chassis Health page displays.
- 106 2 Click the Setup tab. The General Chassis Settings page displays.
- 106 3 Click the Date/Time subtab. The Date/Time page displays.
- 106 4 To synchronize the date and time with a Network Time Protocol (NTP) server, check Enable NTP and specify up to three NTP servers.
- 106 5 To set the date and time manually, uncheck Enable NTP and edit the Date and Time fields, select the Time Zone from the drop-down menu, and then click Apply.
- 106 Chassis Health Page
- 107 Using Chassis Group
- 107 Chassis Group Features
- 108 Setting up a Chassis Group
- 108 1 Log in with administrator privileges to the chassis planned as the leader.
- 108 2 Click SetupÆ Group Administration.
- 108 3 In the Chassis Group page, under Role, select Leader.
- 108 4 Enter the Group name in the Group Name field, and then click Apply.
- 108 1 Login with chassis administrator privileges to the leader chassis.
- 108 2 Select the Lead chassis in the tree.
- 108 3 Click SetupÆ Group Administration.
- 108 4 Under Group Management, enter the member’s IP address or DNS name in the Hostname/IP Address field.
- 108 5 Enter a user name with chassis administrator privileges on the member chassis, in the Username field.
- 108 6 Enter the corresponding password in the Password field.
- 108 7 Select the Apply button.
- 108 8 Repeat step 4 through step 7 to add a maximum of eight members.
- 109 Removing a Member from the Leader
- 109 1 Login with chassis administrator privileges to the leader chassis.
- 109 2 Select the Lead chassis in the tree.
- 109 3 Click SetupÆ Group Administration.
- 109 4 From the Remove Members list, select the member’s name or names to be deleted, and then click Apply.
- 109 Disbanding a Chassis Group
- 109 1 Login with administrator privileges to the leader chassis.
- 109 2 Select the Lead chassis in the tree.
- 109 3 Click SetupÆ Group Administration.
- 109 4 In the Chassis Group page, under Role, select None, and then click Apply.
- 110 Disabling an Individual Member at the Member Chassis
- 110 1 Login with chassis administrator privileges to the member chassis.
- 110 2 Click SetupÆ Group Administration.
- 110 3 Select None, and then click Apply.
- 110 Chassis Component Summary
- 110 Chassis Graphics
- 111 Table 5-1. Server Icon States
- 112 Table 5-2. Chassis Quick Links
- 112 Chassis Health
- 113 Table 5-3. Chassis Page Information
- 113 Selected Component Information
- 114 Table 5-4. Health and Performance Information - Servers
- 114 Table 5-5. Server Properties
- 115 Table 5-6. Quick Links - Servers
- 115 Table 5-7. IOM Health and Performance
- 115 Table 5-8. IOM Properties
- 116 Table 5-9. Quick Links - I/O Modules
- 116 Table 5-10. Active CMC Health and Performance
- 116 Table 5-11. CMC Properties
- 117 Table 5-12. Quick Links - CMC
- 117 Table 5-13. iKVM Health and Performance
- 117 Table 5-14. iKVM Properties
- 117 Table 5-15. Quick Links - iKVM
- 117 Table 5-16. Fan Health and Performance
- 118 Table 5-17. Fan Properties
- 118 Table 5-18. Quick Links - Fan
- 118 Table 5-19. PSU Health and Performance
- 118 Table 5-20. PSU Properties
- 118 Table 5-21. Quick Links - PSU
- 119 Table 5-22. LCD Health and Performance
- 119 Monitoring System Health Status
- 119 Viewing Chassis and Component Summaries
- 119 Figure 5-1. Example of Chassis Graphics in the Web Interface
- 120 Viewing Power Budget Status
- 120 Viewing Server Model Name and Service Tag
- 120 Viewing the Health Status of All Servers
- 121 1 Log in to the CMC Web interface.
- 121 1 Log in to the CMC Web interface.
- 121 2 Select Server Overview in the system tree. The Servers Status page appears.
- 121 Table 5-23. All Servers Status Information
- 121 Item
- 121 Description
- 124 Editing Slot Names
- 125 1 Log in to the CMC Web interface.
- 125 2 Select Server Overview in the Chassis menu in the system tree.
- 125 3 Click Setup Æ Slot Names. The Slot Names page displays.
- 125 4 Type the updated or new name for a slot in the Slot Name field. Repeat this action for each slot you want to rename.
- 125 5 Click Apply.
- 125 6 To restore the default slot name (SLOT-01 to SLOT-16, based on the server's slot position) to the server, press Restore Default Value.
- 125 Using Server’s Host Name as the Slot Name
- 125 1 Log in to the CMC Web interface.
- 125 2 Select Server Overview in the Chassis menu from the system tree.
- 125 3 Click SetupÆ Slot Names. The Slot Names page displays.
- 125 4 Select the Use Host Name for the Slot Name check box.
- 125 5 Click Apply.
- 125 Setting the First Boot Device for Servers
- 126 Table 5-24. Boot Devices
- 126 Boot Device
- 126 Description
- 126 1 Log in to the CMC Web interface.
- 126 2 Click Server Overview in the system tree and then click SetupÆ First Boot Device. A list of servers is displayed as one per row.
- 126 3 Select the boot device you want to use for each server from the list box.
- 126 4 If you want the server to boot from the selected device every time it boots, clear the Boot Once check box for the server.
- 126 5 Click Apply.
- 127 Viewing the Health Status of an Individual Server
- 127 1 Log in to the CMC Web interface.
- 127 2 Move the cursor to hover over an individual server subgraphic.
- 127 3 Click the server subgraphic to select that server’s information and display Quick Links on the right of the chassis graphics.
- 128 1 Log in to the CMC Web interface.
- 128 2 Expand Server Overview in the system tree. All of the servers (1-16) appear in the expanded Servers list.
- 128 3 Click the server (slot) you want to view. The Server Status page displays.
- 128 Table 5-25. Individual Server Status - Properties
- 128 Item
- 128 Description
- 130 Table 5-26. Individual Server Status - iDRAC System Event Log
- 130 Table 5-27. Individual Server Status - iDRAC Network Settings
- 130 Item
- 130 Description
- 131 Table 5-28. Individual Server Status - IPv4 iDRAC Network Settings
- 131 Item
- 131 Description
- 131 Table 5-29. Individual Server Status - IPv6 iDRAC Network Settings
- 131 Item
- 131 Description
- 132 Table 5-30. Individual Server Status - WWN/MAC Address
- 132 Item
- 132 Description
- 132 Viewing the Health Status of IOMs
- 133 1 Log in to the CMC Web interface.
- 133 2 Use the cursor to hover over an individual IOM subgraphic.
- 133 3 Clicking the IOM subgraphic selects that IOM’s information and Quick Links for display to the right of the chassis graphics.
- 133 Viewing the Health Status of the Fans
- 134 1 Log in to the CMC Web interface.
- 134 2 Use the cursor to hover over the an individual fan subgraphic.
- 134 3 Clicking the fan subgraphic selects that fan's information and Quick Links for display to the right of the chassis graphics.
- 134 1 Log in to the CMC Web interface.
- 134 2 Select Fans in the system tree. The Fans Status page displays.
- 135 Table 5-31. Fans Health Status Information
- 135 Item
- 135 Description
- 135 Viewing the iKVM Status
- 136 1 Log in to the CMC Web interface.
- 136 2 Use the cursor to hover over the iKVM subgraphic.
- 136 3 Clicking the iKVM subgraphic selects the iKVM's information and Quick Links for display to the right of the chassis graphics.
- 137 Viewing the Health Status of the PSUs
- 137 1 Log in to the CMC Web interface.
- 137 2 Use the cursor to hover over an individual PSU subgraphic and a corresponding text hint or screen tip is displayed. The text hint provides additional information on that PSU.
- 137 3 Clicking on the PSU subgraphic selects that PSU's information and Quick Links for display to the right of the chassis graphics.
- 137 1 Log in to the CMC Web interface.
- 137 2 Select Power Supplies in the system tree. The Power Supply Status page displays.
- 138 Table 5-32. Power Supply Health Status Information
- 138 Item
- 138 Description
- 138 Table 5-33. System Power Status
- 139 Viewing Status of the Temperature Sensors
- 139 1 Log in to the CMC Web interface.
- 139 2 Select Temperature Sensors in the system tree. The Temperature Sensors Status page displays.
- 139 Table 5-34. Temperature Sensors Health Status Information
- 139 Item
- 139 Description
- 140 Viewing the LCD Status
- 140 1 Log in to the CMC Web interface.
- 141 2 Move the cursor over the LCD subgraphic. The corresponding text hint or screen tip, which provides additional information on the LCD is displayed.
- 141 3 Click the LCD subgraphic to select the LCD's information and display it to the right side of the chassis graphics.
- 141 Viewing World Wide Name/Media Access Control (WWN/MAC) IDs
- 141 Fabric Configuration
- 142 WWN/MAC Addresses
- 142 Configuring CMC Network Properties
- 142 Setting Up Initial Access to CMC
- 142 1 Log in to the Web interface.
- 142 2 Select Chassis Overview in the system tree.
- 143 3 Click the Network tab. The Network Configuration page appears.
- 143 4 Enable or disable DHCP for CMC by selecting or clearing the Use DHCP (For CMC Network Interface IP Address) check box.
- 143 5 If you disabled DHCP, type the IP address, gateway, and subnet mask.
- 143 6 Click Apply Changes at the bottom of the page.
- 143 Configuring the Network LAN Settings
- 143 1 Log in to the Web interface.
- 143 2 Click the Network tab.
- 143 3 Configure the CMC network settings described in Table 5-35 through Table 5-37.
- 143 4 Click Apply Changes.
- 144 Table 5-35. Network Settings
- 144 Setting
- 144 Description
- 147 Table 5-36. IPv4 Settings
- 147 Setting
- 147 Description
- 150 Table 5-37. IPv6 Settings
- 150 Setting
- 150 Description
- 151 Configuring CMC Network Security Settings
- 151 1 Log in to the Web interface.
- 151 2 Click the Network tab.
- 151 3 Click the Advanced Settings button.
- 151 4 Configure the CMC network security settings.
- 151 Table 5-38. Network Security Page Settings
- 151 Settings
- 151 Description
- 152 5 Click Apply to save your settings.
- 153 Configuring VLAN
- 153 1 Log in to the Web interface.
- 153 2 Click the Network tabÆ VLAN subtab.
- 153 3 Configure the CMC/iDRAC VLAN settings.
- 153 Table 5-39. VLAN Tag Settings
- 153 4 Click Apply to save the settings.
- 154 Adding and Configuring CMC Users
- 154 User Types
- 154 Table 5-40. User Types
- 154 Privilege
- 154 Description
- 158 Table 5-41. CMC Group Privileges
- 158 User Group
- 158 Privileges Granted
- 159 Table 5-42. Comparison of Privileges Between CMC Administrators, Power Users, and Guest Users
- 159 Privilege Set
- 159 Administrator Permissions
- 159 Power User Permissions
- 159 Guest User Permissions
- 160 Adding and Managing Users
- 161 1 Log in to the Web interface.
- 161 2 Click the User Authentication tab. The Local Users page appears, listing each user’s user ID, user name, CMC privilege, and login state, including those of the root user. User IDs available for configuration have no user information displayed.
- 161 3 Click an available user ID number. The User Configuration page displays.
- 161 4 Select general settings for the user.
- 161 Table 5-43. General User Settings for Configuring a New or Existing CMC Username and Password
- 161 Property
- 161 Description
- 162 5 Assign the user to a CMC user group. Table 5-40 describes CMC user privileges.
- 162 6 Click Apply Changes.
- 163 Configuring and Managing Microsoft Active Directory Certificates
- 163 1 Log in to the Web interface.
- 163 2 Click the User Authentication tab, and then click the Directory Services subtab. Select the radio button for Microsoft Active Directory Standard Schema or Extended Schema. The Active Directory tables appear.
- 163 Common Settings
- 163 Table 5-44. Common Settings
- 167 Standard Schema Settings
- 167 Extended Schema Settings
- 168 Managing Active Directory Certificates
- 169 Kerberos Keytab
- 169 Configuring and Managing Generic Lightweight Directory Access Protocol Services
- 169 1 Log in to the Web interface.
- 169 2 Click the User Authentication tab, and then click the Directory Services subtab. The Directory Services page appears.
- 169 3 Click the radio button associated with Generic LDAP.
- 169 4 Configure the options shown and click Apply.
- 170 Table 5-45. Common Settings
- 171 Selecting Your LDAP Servers
- 172 Managing LDAP Group Settings
- 172 Managing LDAP Security Certificates
- 173 Securing CMC Communications Using SSL and Digital Certificates
- 173 Secure Sockets Layer (SSL)
- 174 Certificate Signing Request (CSR)
- 174 Accessing the SSL Main Menu
- 174 1 Log in to the Web interface.
- 174 2 Click the Network tab, and then click the SSL subtab. The SSL Main Menu page appears.
- 175 Generating a New Certificate Signing Request
- 175 Table 5-46. SSL Main Menu Options
- 175 Field
- 175 Description
- 176 1 From the SSL Main Menu page, select Generate a New Certificate Signing Request (CSR), and then click Next. The Generate Certificate Signing Request (CSR) page displays.
- 176 2 Type a value for each CSR attribute value.
- 176 3 Click Generate. A File Download dialog box appears.
- 176 4 Save the csr.txt file to your management station or shared network. (You may also open the file at this time and save it later.) You must later submit this file to a certificate authority.
- 177 Table 5-47. Generate Certificate Signing Request (CSR) Page Options
- 177 Field
- 177 Description
- 178 Uploading a Server Certificate
- 178 1 From the SSL Main Menu page, select Upload Server Certificate Based on Generated CSR, and then click Next. The Certificate Upload page displays.
- 178 2 Type the file path in the text field, or click Browse to select the file.
- 178 3 Click Apply. If the certificate is invalid, an error message displays.
- 178 Uploading Webserver Key and Certificate
- 178 1 Select Upload Webserver Key and Certificate option, and then click Next.
- 178 2 Enter Private Key File using the browse menu.
- 178 3 Enter Certificate File using the browse menu.
- 178 4 After both the files are uploaded, click Apply. If the Web server key and certificate do not match, an error message is displayed.
- 179 Viewing a Server Certificate
- 179 Table 5-48. Certificate Information
- 179 Field
- 179 Description
- 179 Managing Sessions
- 179 1 Log in to CMC through the Web.
- 179 2 Click the Network tab then click the Sessions subtab.
- 179 3 On the Sessions page, locate the session you want to terminate and click the appropriate button.
- 180 Table 5-49. Sessions Properties
- 180 Property
- 180 Description
- 180 Configuring Services
- 181 1 Log in to the CMC Web interface.
- 181 2 Click the Network tab.
- 181 3 Click the Services subtab. The Services page appears.
- 181 4 Configure the following services as required:
- 181 5 Click Apply, and then update all default time outs and maximum time out limits
- 181 Table 5-50. CMC Serial Console Settings
- 181 Setting
- 181 Description
- 183 Table 5-51. Web Server Settings
- 183 Setting
- 183 Description
- 185 Table 5-52. SSH Settings
- 185 Setting
- 185 Description
- 186 Table 5-53. Telnet Settings
- 186 Setting
- 186 Description
- 187 Table 5-54. Remote RACADM Settings
- 187 Setting
- 187 Description
- 187 Table 5-55. SNMP Configuration
- 187 Setting
- 187 Description
- 188 Table 5-56. Remote Syslog Configuration
- 188 Setting
- 188 Description
- 188 Configuring Power Budgeting
- 189 Managing Firmware Updates
- 189 Viewing the Current Firmware Versions
- 189 1 Click on the device name or select the Select/Deselect All check box.
- 189 2 Click Apply Update.
- 189 1 Log in to the Web interface. For more information, see "Accessing the CMC Web Interface" on page 103.
- 189 2 Click Chassis Overview in the system tree.
- 189 3 Click the Update tab. The Firmware Update page appears.
- 190 1 Log in to the Web interface. For more information, see "Accessing the CMC Web Interface" on page 103.
- 190 2 Click Server Overview in the system tree.
- 190 3 Click the Update tab. The Server Component Update appears.
- 190 Updating Firmware
- 190 Updating the CMC Firmware
- 191 1 On the Firmware Update page, select CMC or CMCs to update by selecting the Update Targets check box for CMC(s). Both CMCs can be updated at the same time.
- 191 2 Click the Apply CMC Update button below the CMC component list.
- 191 3 In the Firmware Image field, enter the path to the firmware image file on your management station or shared network, or click Browse to navigate to the file location.
- 191 4 Click Begin Firmware Update. The Firmware Update Progress section provides firmware update status information. A status indica...
- 192 5 For a standby CMC, when the update is complete the Update State field displays "Done". For an active CMC, during the final pha...
- 192 Updating the iKVM Firmware
- 192 1 Log back in to CMC Web interface.
- 192 2 Select Chassis Overview in the system tree.
- 192 3 Click the Update tab. The Firmware Update page appears.
- 192 4 Select the iKVM to update by selecting the Update Targets check box for that iKVM.
- 192 5 Click the Apply iKVM Update button below the iKVM component list.
- 192 6 In the Firmware Image field, enter the path to the firmware image file on your management station or shared network, or click Browse to navigate to the file location.
- 192 7 Click Begin Firmware Update.
- 192 8 Click Yes to continue. The Firmware Update Progress section provides firmware update status information. A status indicator di...
- 193 Updating the IOM Infrastructure Device Firmware
- 193 1 Log back in to CMC Web interface.
- 193 2 Select Chassis Overview in the system tree.
- 193 3 Click the Update tab. The Firmware Update page appears.
- 193 4 Select the IOM device to update by selecting the Update Targets check box for that IOM device.
- 193 5 Click the Apply IOM Update button below the IOM component list.
- 193 6 Click Begin Firmware Update. The Firmware Update Progress section provides firmware update status information. A status indica...
- 194 Updating the Server iDRAC Firmware
- 194 1 Log back in to the CMC Web interface.
- 194 2 Select Chassis Overview in the system tree.
- 194 3 Click the Update tab. The Firmware Update page appears.
- 194 4 Select the iDRAC or iDRACs to update by selecting the Update Targets check box those devices.
- 194 5 Click the Apply iDRAC Update button below the iDRAC component list.
- 194 6 In the Firmware Image field, enter the path to the firmware image file on your management station or shared network, or click Browse to navigate to the file location.
- 194 7 Click Begin Firmware Update. The Firmware Update Progress section provides firmware update status information. A status indica...
- 195 Recovering iDRAC Firmware Using CMC
- 195 1 Download the latest iDRAC firmware to your management computer from support.dell.com.
- 195 2 Log in to the Web interface (see "Accessing the CMC Web Interface" on page 103).
- 195 3 Click Chassis Overview in the system tree.
- 195 4 Click the Update tab. The Firmware Update page appears.
- 195 5 Select the iDRAC or iDRACs of the same model to update by selecting the Update Targets check box those devices.
- 195 6 Click the Apply iDRAC Update button below the iDRAC component list.
- 195 7 Click Browse, browse to the iDRAC firmware image you downloaded, and click Open.
- 195 8 Click Begin Firmware Update. Additional instructions to follow:
- 196 Managing iDRAC
- 196 iDRAC QuickDeploy
- 196 1 Log in to the CMC Web interface.
- 196 2 Select Server Overview in the system tree.
- 196 3 Click the Setup tab. The Deploy iDRAC page appears.
- 196 4 Set the QuickDeploy settings accordingly.
- 197 Table 5-57. QuickDeploy Settings
- 197 Setting
- 197 Description
- 198 5 To save the selections click the Save QuickDeploy Settings button. If you made changes to the iDRAC network setting, click the Apply iDRAC Network Settings button to deploy the settings to the iDRAC.
- 199 6 To update the table to the last saved QuickDeploy settings, and restore the iDRAC Network settings to the current values for each installed server, click Refresh.
- 200 iDRAC Network Settings
- 200 1 Log in to the CMC Web interface.
- 200 2 Select Server Overview in the system tree.
- 200 3 Click the Setup tab.
- 200 4 Select the check box for QuickDeploy Enabled to enable the QuickDeploy settings.
- 200 5 Set the remaining iDRAC Network Settings accordingly.
- 200 Table 5-58. iDRAC Network Settings
- 200 Setting
- 200 Description
- 202 6 To deploy the setting to iDRAC, click Apply iDRAC Network Settings button. If you made changes to the QuickDeploy settings, they are also saved.
- 202 7 To restore the iDRAC Network settings to the current values for each installed server, and update the QuickDeploy table to the last saved QuickDeploy settings click Refresh.
- 202 Launching Remote Console from CMC GUI
- 202 1 Click on the specified server in the chassis graphic.
- 202 2 On Quicklinks, click the Launch Remote Console link.
- 202 1 On System tree, select Server Overview.
- 202 2 Click Launch Remote Console in the table for the specified server.
- 202 1 Expand Server Overview in the system tree. All servers (1-16) appear in the expanded servers list.
- 202 2 In the system tree, click the server you want to view. The Server Status page appears.
- 202 3 Click Launch Remote Console.
- 203 Launching iDRAC using Single Sign-On
- 203 1 Log in to the CMC Web interface.
- 203 2 Select Server Overview in the system tree. The Servers Status page appears.
- 203 3 Click the Launch iDRAC GUI button for the server you want to manage.
- 203 1 Log in to the CMC Web interface.
- 203 2 Expand Server Overview in the system tree. All of the servers (1-16) appear in the expanded Servers list.
- 203 3 Click the server you want to view. The Server Status page displays.
- 203 4 Click the Launch iDRAC GUI button.
- 205 FlexAddress
- 205 Viewing FlexAddress Status
- 205 Viewing Chassis FlexAddress Status
- 206 1 Log in to the Web interface (see "Accessing the CMC Web Interface" on page 103).
- 206 2 Click Chassis Overview in the system tree.
- 206 3 Click the Setup tab. The General Setup page appears. The FlexAddress entry has a value of Active or Not Active; a value of act...
- 206 1 Log in to the Web interface ("Accessing the CMC Web Interface" on page 103).
- 206 2 Click Server OverviewÆ PropertiesÆ WWN/MAC.
- 206 3 The FlexAddress Summary page is displayed. This page allows you to view the WWN configuration and MAC addresses for all slots in the chassis.
- 206 4 For additional information, click Help.
- 207 Viewing Server FlexAddress Status
- 207 1 Log in to the Web interface (see "Accessing the CMC Web Interface" on page 103).
- 207 2 Expand Server Overview in the system tree. All of the servers (1-16) appear in the expanded Servers list.
- 207 3 Click the server you want to view.
- 207 4 Click the Setup tab, and the FlexAddress subtab. The Deploy FlexAddress page is displayed. This page allows you to view the WWN configuration and MAC addresses for the selected server.
- 207 Table 5-59. Status Page Information
- 208 5 For additional information, click Help.
- 209 Configuring FlexAddress
- 209 Chassis-Level Fabric and Slot FlexAddress Configuration
- 209 1 Log on to the Web interface (see "Accessing the CMC Web Interface" on page 103).
- 209 2 Click Server Overview in the system tree.
- 209 3 Click the Setup tabÆ FlexAddress subtab. The Deploy FlexAddress page is displayed.
- 209 4 The Select Fabrics for Chassis-Assigned WWN/MACs displays a check box for Fabric A, Fabric B, Fabric C, and iDRAC.
- 209 5 Click the check box for each fabric you want to enable FlexAddress on. To disable a fabric, click the check box to clear the selection.
- 210 6 Click the Enabled check box for each slot you want to enable FlexAddress on. If you want to select all slots, use the Select/Deselect All check box. To disable a slot, click the Enabled check box to clear the selection.
- 210 7 Click Apply to save the changes.
- 210 Server-Level Slot FlexAddress Configuration
- 210 1 Log in to the Web interface (see "Accessing the CMC Web Interface" on page 103).
- 210 2 Expand Server Overview in the system tree. All of the servers (1-16) appear in the expanded Servers list.
- 210 3 Click the server you want to view. The Server Status page displays.
- 210 4 Click the Setup tab, and the FlexAddress subtab. The FlexAddress Status page is displayed.
- 210 5 Use the pull down menu for FlexAddress Enabled to make your selection; select Yes to enable FlexAddress or select No to disable FlexAddress.
- 210 6 Click Apply to save the changes. For additional information, click Help.
- 211 Remote File Sharing
- 211 1 Log in to the Web interface (see "Accessing the CMC Web Interface" on page 103).
- 211 2 Click Server Overview in the system tree.
- 211 3 Click the Setup tab, and the Remote File Sharing subtab. The Deploy Remote File Share page is displayed.
- 211 4 Set the Remote File Sharing settings.
- 211 Table 5-60. Remote File Sharing Settings
- 212 5 Click Connect to connect to a remote file share. To connect a remote file share, you must provide the path, user name, and password. A successful operation allows access to the media.
- 213 Frequently Asked Questions
- 213 Table 5-61. Managing and Recovering a Remote System
- 213 Question
- 213 Answer
- 213 1 In the System tree, click Chassis Overview.
- 213 2 Click the Network tab, and then click Network. The Network Configuration page appears.
- 213 3 Select the Register CMC on DNS check box.
- 213 4 Enter the CMC name In the DNS CMC Name field.
- 213 5 Click Apply Changes.
- 215 Troubleshooting CMC
- 217 6
- 217 Using FlexAddress
- 218 Activating FlexAddress
- 219 1 Update all mezzanine card firmware and BIOS.
- 219 2 Update server module BIOS.
- 219 3 Update iDRAC firmware on the server module.
- 219 4 Update all CMC firmware in the chassis; if redundant CMCs are present, ensure both are updated.
- 219 5 Insert the SD card into the passive module for a redundant CMC module system or into the single CMC module for a non-redundant system.
- 220 Verifying FlexAddress Activation
- 220 Table 6-1. Status Messages Returned by featurecard -s Command
- 221 Deactivating FlexAddress
- 222 Deactivating FlexAddress
- 222 Configuring FlexAddress Using the CLI
- 223 Additional FlexAddress Configuration for Linux
- 223 Viewing FlexAddress Status Using the CLI
- 224 Configuring FlexAddress Using the GUI
- 224 Wake-On-LAN with FlexAddress
- 224 Troubleshooting FlexAddress
- 224 1 What happens if a feature card is removed?
- 224 2 What happens if a feature card that was used in one chassis is removed and put into another chassis?
- 225 3 What happens if the feature card is removed and a non-FlexAddress card is installed?
- 225 4 If the chassis service tag is reprogrammed, what happens if there is a feature card bound to that chassis?
- 226 5 Do I get an error if I have two feature cards installed in my redundant CMC system?
- 226 6 Does the SD card have a write protection lock on it?
- 226 7 What happens if there isn’t an SD card in the active CMC module?
- 226 8 What happens to my FlexAddress feature if the server BIOS is updated from version 1.xx to version 2.xx?
- 227 9 What happens if a chassis with a single CMC is downgraded with firmware prior to 1.10?
- 227 10 What happens if you are replacing a CMC unit with one that has firmware prior to 1.10 in a chassis with redundant CMCs?
- 227 a Ensure the active CMC firmware is always version 1.10 or later.
- 227 b Remove the standby CMC and insert the new CMC in its place.
- 227 c From the Active CMC, upgrade the standby CMC firmware to 1.10 or later.
- 227 11 The SD card was not in the chassis when I executed the deactivation command on the FlexAddress. How do I recover my SD card now?
- 228 12 I have the SD card properly installed and all the firmware/software updates installed. I see that FlexAddress is active, but I can’t see anything on the server deployment screen to deploy it? What is wrong?
- 228 13 What happens to FlexAddress if I need to reset my chassis configuration using the RACADM command, racresetcfg?
- 228 Command Messages
- 228 Table 6-2. FlexAddress Commands and Output
- 231 FlexAddress DELL SOFTWARE LICENSE AGREEMENT
- 235 7
- 235 Using FlexAddress Plus
- 235 Activating FlexAddress Plus
- 235 Table 7-1. Updates Required for Flexaddress Plus
- 236 FlexAddress vs FlexAddress Plus
- 236 Figure 7-1. FlexAdress (FA) vs FlexPlusAddress (FA+) Features
- 237 Scheme 1 and Scheme 2 MAC Address Allocation
- 238 MAC Address Allocation Example
- 241 8
- 241 Using the CMC Directory Service
- 241 Using CMC with Microsoft Active Directory
- 241 Active Directory Schema Extensions
- 241 Standard Schema Versus Extended Schema
- 242 Standard Schema Active Directory Overview
- 242 Figure 8-1. Configuration of CMC with Active Directory and Standard Schema
- 243 Table 8-1. Default Role Group Privileges
- 243 Role Group
- 243 Default Privilege Level
- 243 Permissions Granted
- 243 Bit Mask
- 244 Configuring Standard Schema Active Directory to Access CMC
- 244 1 On an Active Directory server (domain controller), open the Active Directory Users and Computers Snap-in.
- 244 2 Create a group or select an existing group. The name of the group and the name of this domain must be configured on CMC using the Web interface or RACADM.
- 244 3 Add the Active Directory user as a member of the Active Directory group to access CMC.
- 244 Configuring CMC With Standard Schema Active Directory and Web Interface
- 244 1 Log in to the CMC Web interface.
- 244 2 Select Chassis in the system tree.
- 244 3 Click User AuthenticationÆ Directory Services.The Directory Services page is displayed.
- 244 4 Select the radio button next to Microsoft Active Directory (Standard Schema). The Active Directory Configuration and Management page appears.
- 245 5 In the Common Settings section:
- 245 a Select the Enable Active Directory check box.
- 245 b Type the Root Domain Name.
- 245 c Type the Timeout in seconds. Timeout range is 15-300 seconds. Default timeout period is 90 seconds.
- 245 6 If you want the directed call to search the domain controller and global catalog, select the Search AD Server to search (Optional) check box, and do the following:
- 245 a In the Domain Controller text field, type the server where your Active Directory service is installed.
- 245 b In the Global Catalog text field, type the location of the global catalog on the Active Directory domain controller. The global catalog provides a resource for searching an Active Directory forest.
- 245 7 Click Apply to save your settings.
- 245 8 In the Standard Schema Settings section, click a Role Group. The Configure Role Group page appears.
- 245 9 Type the Group Name. The group name identifies the role group in the Active Directory associated with the CMC card.
- 245 10 Type the Group Domain. The Group Domain is the fully qualified root domain name for the forest.
- 245 11 In the Role Group Privileges page, select privileges for the group.
- 245 12 Click Apply to save the Role Group settings.
- 245 13 Click Go Back To Configuration page.
- 246 14 Upload your domain forest Root certificate authority-signed certificate into CMC. In the Certificate Management section, type the file path of the certificate or browse to the certificate file. Click the Upload button to transfer the file to CMC.
- 246 15 Click Apply. The CMC Web server automatically restarts after you click Apply.
- 246 16 Log out and then log in to CMC to complete the CMC Active Directory feature configuration.
- 246 17 Select Chassis in the system tree.
- 246 18 Click the Network tab.
- 246 19 Click the Network subtab. The Network Configuration page appears.
- 246 20 If Use DHCP (for CMC Network Interface IP Address) is selected under Network Settings, select Use DHCP to obtain DNS server address.
- 246 21 Click Apply Changes.
- 247 Configuring CMC With Standard Schema Active Directory and RACADM
- 247 1 Open a serial/Telnet/SSH text console to the CMC, and type:
- 248 2 Specify a DNS server using one of the following options:
- 248 Extended Schema Overview
- 248 Active Directory Schema Extensions
- 249 Overview of the RAC Schema Extensions
- 249 Active Directory Object Overview
- 250 Figure 8-2. Typical Setup for Active Directory Objects
- 251 Figure 8-3. Setting Up Active Directory Objects in a Single Domain
- 252 1 Create two Association Objects.
- 252 2 Create two RAC Device Objects, RAC1 and RAC2, to represent the two CMCs.
- 252 3 Create two Privilege Objects, Priv1 and Priv2, in which Priv1 has all privileges (administrator) and Priv2 has login privilege.
- 252 4 Group user1 and user2 into Group1.
- 252 5 Add Group1 as Members in Association Object 1 (A01), Priv1 as Privilege Objects in A01, and RAC1, RAC2 as RAC Devices in A01.
- 252 6 Add User3 as Members in Association Object 2 (A02), Priv2 as Privilege Objects in A02, and RAC2 as RAC Devices in A02.
- 253 Figure 8-4. Setting Up Active Directory Objects in Multiple Domains
- 253 1 Ensure that the domain forest function is in Native or Windows 2003 mode.
- 253 2 Create two Association Objects, A01 (of Universal scope) and A02, in any domain.
- 253 3 Create two RAC Device Objects, RAC1 and RAC2, to represent the two CMCs.
- 253 4 Create two Privilege Objects, Priv1 and Priv2, in which Priv1 has all privileges (administrator) and Priv2 has login privilege.
- 253 5 Group user1 and user2 into Group1. The group scope of Group1 must be Universal.
- 254 6 Add Group1 as Members in Association Object 1 (A01), Priv1 as Privilege Objects in A01, and RAC1, RAC2 as RAC Devices in A01.
- 254 7 Add User3 as Members in Association Object 2 (A02), Priv2 as Privilege Objects in A02, and RAC2 as RAC Devices in A02.
- 254 Configuring Extended Schema Active Directory to Access Your CMC
- 254 1 Extend the Active Directory schema (see "Extending the Active Directory Schema" on page 254).
- 254 2 Extend the Active Directory Users and Computers Snap-In (see "Installing the Dell Extension to the Active Directory Users and Computers Snap-In" on page 261).
- 254 3 Add CMC users and their privileges to Active Directory (see "Adding CMC Users and Privileges to Active Directory" on page 262).
- 254 4 Enable SSL on each of your domain controllers.
- 254 5 Configure the CMC Active Directory properties using either the CMC Web interface or the RACADM (see "Configuring CMC With Exte...
- 254 Extending the Active Directory Schema
- 255 Using the Dell Schema Extender
- 255 1 In the Welcome screen, click Next.
- 255 2 Read and understand the warning and click Next.
- 255 3 Select Use Current Log In Credentials or enter a user name and password with schema administrator rights.
- 256 4 Click Next to run the Dell Schema Extender.
- 256 5 Click Finish.
- 256 Table 8-2. Class Definitions for Classes Added to the Active Directory Schema
- 256 Class Name
- 256 Assigned Object Identification Number (OID)
- 256 Table 8-3. dellRacDevice Class
- 257 Table 8-4. dellAssociationObject Class
- 257 Table 8-5. dellRAC4Privileges Class
- 258 Table 8-6. dellPrivileges Class
- 258 Table 8-7. dellProduct Class
- 258 Table 8-8. List of Attributes Added to the Active Directory Schema
- 258 Assigned OID/Syntax Object Identifier
- 258 Single Valued
- 261 Installing the Dell Extension to the Active Directory Users and Computers Snap-In
- 261 Installing the Administrator Pack
- 261 Opening the Active Directory Users and Computers Snap-In
- 261 1 If you are logged into the domain controller, click Start Admin ToolsÆ Active Directory Users and Computers.
- 262 2 In the Console 1 window, click File (or Console on systems running Windows 2000).
- 262 3 Click Add/Remove Snap-in.
- 262 4 Select the Active Directory Users and Computers Snap-In and click Add.
- 262 5 Click Close and click OK.
- 262 Adding CMC Users and Privileges to Active Directory
- 262 1 Create a RAC device Object.
- 262 2 Create a Privilege Object.
- 262 3 Create an Association Object.
- 262 4 Add objects to an Association Object.
- 262 Creating a RAC Device Object
- 262 1 In the MMC Console Root window, right-click a container.
- 262 2 Select NewÆ Dell RAC Object.
- 262 3 Type a name for the new object. The name must be identical to CMC Name that you type in step 8a of "Configuring CMC With Extended Schema Active Directory and the Web Interface" on page 264.
- 262 4 Select RAC Device Object.
- 262 5 Click OK.
- 262 Creating a Privilege Object
- 262 1 In the Console Root (MMC) window, right-click a container.
- 262 2 Select NewÆ Dell RAC Object.
- 263 3 Type a name for the new object.
- 263 4 Select Privilege Object.
- 263 5 Click OK.
- 263 6 Right-click the privilege object that you created, and select Properties.
- 263 7 Click the RAC Privileges tab and select the privileges that you want the user to have. For more information about CMC user privileges, see "User Types" on page 154.
- 263 Creating an Association Object
- 263 1 In the Console Root (MMC) window, right-click a container.
- 263 2 Select NewÆ Dell RAC Object.
- 263 3 Type a name for the new object.
- 263 4 Select Association Object.
- 263 5 Select the scope for the Association Object.
- 263 6 Click OK.
- 263 Adding Objects to an Association Object
- 263 Adding Users or User Groups
- 263 1 Right-click the Association Object and select Properties.
- 264 2 Select the Users tab and click Add.
- 264 3 Type the user or User Group name and click OK.
- 264 Adding Privileges
- 264 1 Select the Privileges Object tab and click Add.
- 264 2 Type the Privilege Object name and click OK.
- 264 Adding RAC Devices or RAC Device Groups
- 264 1 Select the Products tab and click Add.
- 264 2 Type the RAC device or RAC device group name and click OK.
- 264 3 In the Properties window, click Apply and click OK.
- 264 Configuring CMC With Extended Schema Active Directory and the Web Interface
- 264 1 Log in to the CMC Web interface.
- 264 2 Select Chassis in the system tree.
- 264 3 Click User AuthenticationÆ Directory Services.
- 264 4 Select Microsoft Active Directory (Extended Schema).
- 264 5 In the Common Settings section:
- 264 a Verify that the Enable Active Directory check box is checked.
- 264 b Type the Root Domain Name.
- 265 c Type the Timeout time in seconds. Configuration range: 15-300 seconds. Default: 90 seconds
- 265 6 Optional: If you want the directed call to search the domain controller and global catalog, select the Search AD Server to search (Optional) check box, then:
- 265 a In the Domain Controller text field, type the server where your Active Directory service is installed.
- 265 b In the Global Catalog text field, type the location of the global catalog on the Active Directory domain controller. The global catalog provides a resource for searching an Active Directory forest.
- 265 7 In the Extended Schema Settings section:
- 265 a Type the CMC Device Name. The CMC Name uniquely identifies the CMC card in Active Directory. The CMC Name must be the same as ...
- 265 b Type the CMC Domain Name (example: cmc.com). The CMC Domain Name is the DNS name (string) of the domain where the Active Direc...
- 265 8 Click Apply to save your settings.
- 266 9 In the Manage Certificates section, type the file path of the certificate in the text field, or click Browse to select the certificate file. Click the Upload button to transfer the file to CMC.
- 266 10 Click Apply. The CMC Web server automatically restarts after you click Apply.
- 266 11 Log back in to the CMC Web interface.
- 266 12 Select Chassis in the system tree, click the Network tab, then click the Network subtab. The Network Configuration page is displayed.
- 266 13 If Use DHCP (for CMC Network Interface IP Address) is enabled (checked), do one of the following:
- 267 14 Click Apply Changes.
- 267 Configuring CMC With Extended Schema Active Directory and RACADM
- 267 1 Open a serial/Telnet/SSH text console to CMC, log in, and type:
- 268 2 Specify a DNS server using one of the following options:
- 269 Frequently Asked Questions
- 269 Table 8-9. Using CMC With Active Directory: Frequently Asked Questions
- 269 Question
- 269 Answer
- 271 1 Ensure that you use the correct user domain name during a login and not the NetBIOS name.
- 271 2 If you have a local CMC user account, log into CMC using your local credentials.
- 271 a Ensure that you have checked the Enable Active Directory check box on the CMC Active Directory configuration page.
- 271 b Ensure that the DNS setting is correct on the CMC Networking configuration page.
- 271 c Ensure that you have uploaded the Active Directory certificate from your Active Directory root certificate authority-signed certificate to CMC.
- 271 d Check the Domain Controller SSL certificates to ensure that they have not expired.
- 271 e Ensure that your CMC Name, Root Domain Name, and CMC Domain Name match your Active Directory environment configuration.
- 271 f Ensure that the CMC password has a maximum of 127 characters. While CMC can support passwords of up to 256 characters, Active Directory only supports passwords that have a maximum length of 127 characters.
- 272 Configuring Single Sign-On
- 272 System Requirements
- 273 Client Systems
- 273 CMC
- 273 Configuring Settings
- 273 Prerequisites
- 273 Configuring Active Directory
- 274 Configuring CMC
- 274 Uploading the Kerberos Keytab File
- 275 1 Navigate to the User Authentication tabÆ Directory Services subtab. Ensure that Microsoft Active Directory Standard or Extended Schema is selected. If not, select your preference and click Apply.
- 275 2 Click Browse on the Kerberos Keytab Upload section, navigate to the folder where the keytab file is saved and click Upload.
- 275 Enabling Single Sign-On
- 275 1 Click Chassis Management Controller Network Security tabÆ Active DirectoryÆ Configure Active Directory.
- 275 2 On the Active Directory Configuration and Management page, select:
- 275 3 Scroll to the bottom of the page and click Apply.
- 276 Configuring the Browser For Single Sign-On Login
- 276 Internet Explorer
- 276 1 In the Internet Explorer, select ToolsÆ Internet Options.
- 276 2 On the Security tab, under Select a zone to view or change security settings, select Local Intranet.
- 276 3 Click Sites.
- 276 4 Click Advanced.
- 276 5 In the Add this site to the zone, type the name of CMC and the domain it belongs to and click Add.
- 276 Mozilla Firefox
- 276 1 In Firefox, type about:config in the Address bar.
- 276 2 In the Filter text box, type negotiate.
- 276 3 From the list, double-click network.negotiate-auth.trusted-uris.
- 276 4 In the Enter string value dialog box, type the CMC's domain name and click OK.
- 277 Logging into CMC Using Single Sign-On
- 277 1 Log into the client system using your network account.
- 277 2 Access the CMC Web page using
- 277 3 Click Login.
- 278 Configuring Smart Card Two-Factor Authentication
- 278 System Requirements
- 278 Configuring Settings
- 279 Configuring Active Directory
- 279 1 Set up Kerberos realm & Key Distribution Center (KDC) for Active Directory, if not already configured (ksetup).
- 279 2 Create Active Directory users for each CMC, configured to use Kerberos DES encryption but not pre-authentication.
- 279 3 Register the CMC users to the Key Distribution Center with Ktpass (this also outputs a key to upload to CMC).
- 279 Configuring CMC
- 279 Uploading the Kerberos Keytab File
- 279 1 Navigate to the User Authentication tabÆ Directory Services subtab. Ensure that Microsoft Active Directory Standard or Extended Schema is selected. If not, select your preference and click Apply.
- 279 2 Click Browse in the Kerberos Keytab Upload section, navigate to the folder where the keytab file is saved and click Upload.
- 280 Enabling Smart Card Authentication
- 280 1 Navigate to the User Authentication tabÆ Directory Services subtab. Ensure that Microsoft Active Directory Standard or Extended Schema is selected.
- 280 2 In the Common Settings Section, select:
- 280 3 Scroll to the bottom of the page and click Apply.
- 280 Configuring the Browser For Smart Card Login
- 280 Mozilla Firefox
- 280 Internet Explorer
- 281 Logging into CMC Using Smart Card
- 281 1 Log into the client system using your network account.
- 281 2 Access the CMC Web page using
- 281 3 Insert the Smart Card into the reader and click OK.
- 281 4 Optionally, select a session timeout. This is the amount of time you stay logged in with no activity. The default value is defined as the Web Service Idle Timeout. See Configuring Services for more details.
- 281 5 Enter the PIN and click OK.
- 281 Troubleshooting the Smart Card Login
- 282 Using CMC with Generic LDAP
- 283 Figure 8-5. Configuration of CMC with Generic LDAP
- 283 Configuring the Generic LDAP Directory to Access CMC
- 283 Authentication and Authorization of the LDAP Users
- 283 1 Optionally bind to the Directory Service. The default is an anonymous bind.
- 283 2 Search for the user based upon their user login. The default attribute is uid.
- 283 3 If more than one object is found, then the process returns an error.
- 284 4 Unbind and perform a bind with the user's DN and password.
- 284 5 If the bind fails, then the login fails.
- 284 1 Search through each configured group for the user's DN within the member or uniqueMember attributes. This field can be configured by the administrator.
- 284 2 For every group the user is a member of, add their privileges together.
- 284 Configuring Generic LDAP Directory Service Using CMC Web-Based Interface
- 284 1 Log in to the Web interface.
- 284 2 Click the User Authentication tab, and then click the Directory Services subtab. The Directory Services page appears.
- 284 3 Click the radio button associated with Generic LDAP.
- 284 4 Configure the options shown and click Apply.
- 285 Table 8-10. Common Settings
- 286 Selecting Your LDAP Servers
- 287 Managing LDAP Group Settings
- 287 Managing LDAP Security Certificates
- 288 Configuring Generic LDAP Directory Service Using RACADM
- 288 Usage
- 288 Getting Help
- 289 9
- 289 Power Management
- 289 Overview
- 289 AC Redundancy Mode
- 290 AC Redundancy Levels
- 290 Figure 9-1. Figure 8-2. 2 PSUs per grid and a power failure on grid 1
- 291 Power Supply Redundancy Mode
- 291 Figure 9-2. Power Supply Redundancy: Totally 4 PSUs with a failure of one PSU.
- 292 No Redundancy Mode
- 292 Figure 9-3. No Redundancy with three PSUs in the chassis
- 293 Power Budgeting for Hardware Modules
- 293 Figure 9-4. Chassis With Six-PSU Configuration
- 295 Server Slot Power Priority Settings
- 296 Dynamic Power Supply Engagement
- 298 Redundancy Policies
- 298 Table 9-1. Default Redundancy Configuration
- 298 PSU Configuration
- 298 Default Redundancy Policy
- 298 Default Dynamic PSU Engagement Setting
- 298 AC Redundancy
- 298 Power Supply Redundancy
- 299 No Redundancy
- 299 Power Conservation and Power Budget Changes
- 299 1 Click Servers in the system tree.
- 299 2 Click PowerÆ Priority.
- 299 Power Conservation and Max Conservation Mode
- 300 Using the Web Interface
- 300 1 Click Chassis Overview in the system tree.
- 300 2 Click PowerÆ Configuration.
- 300 3 Select the Max Power Conservation Mode box to enable maximum power conservation and click Apply.
- 300 4 Clear the Max Power Conservation Mode box to restore normal operation and click Apply.
- 300 Using RACADM
- 300 110V PSUs Operation
- 301 Using the Web Interface
- 301 1 Click Chassis Overview in the system tree.
- 301 2 Click PowerÆ Configuration.
- 301 3 Select Allow 110 VAC Operation and click Apply.
- 301 Using RACADM
- 301 1 Open a serial/Telnet/SSH text console to CMC and log in.
- 301 2 Enable 110 VAC PSUs:
- 301 Server Performance Over Power Redundancy
- 301 Using the Web Interface
- 301 1 Click Chassis Overview in the system tree.
- 301 2 Click PowerÆ Configuration.
- 301 3 Select Server Performance Over Power Redundancy and click Apply.
- 302 1 Click Chassis Overview in the system tree.
- 302 2 Click PowerÆ Configuration.
- 302 3 Clear Server Performance Over Power Redundancy and click Apply.
- 302 Using RACADM
- 302 1 Open a serial/Telnet/SSH text console to CMC and log in.
- 302 2 Enable Server Performance Over Power Redundancy:
- 302 1 Open a serial/Telnet/SSH text console to CMC and log in.
- 302 2 Disable Server Performance Over Power Redundancy:
- 302 Remote Logging
- 302 Using the Web Interface
- 302 1 Click Chassis Overview in the system tree.
- 302 2 Click PowerÆ Configuration.
- 303 3 Select Power Remote Logging, to enable you to log power events to a remote host.
- 303 4 Specify the required logging interval (1-1440 minutes).
- 303 5 Click Apply, to save changes.
- 303 Using RACADM
- 303 1 To enable the power remote logging feature, enter the following command:
- 303 2 To specify the desired logging interval, enter the following command:
- 303 3 To determine if the power remote logging feature is enabled, enter the following command:
- 303 4 To determine the power remote logging interval, enter the following command:
- 304 PSU Failure With Degraded or No Redundancy Policy
- 304 New Server Engagement Policy
- 305 Table 9-2. CMC Response When a Server Power-On is Attempted
- 305 Worst Case Power is Available
- 305 CMC Response
- 305 Server Power On
- 305 Table 9-3. Chassis Impact from PSU Failure or Removal
- 305 PSU Configuration
- 305 Dynamic PSU Engagement
- 305 Firmware Response
- 306 PSU Removals With Degraded or No Redundancy Policy
- 306 Limits
- 306 Power Supply and Redundancy Policy Changes in System Event Log
- 307 Table 9-4. SEL Events for Power Supply Changes
- 307 Table 9-5. SEL Events for Power Redundancy Status Changes
- 308 Redundancy Status and Overall Power Health
- 308 Configuring and Managing Power
- 308 Viewing the Health Status of the PSUs
- 308 Using the Web Interface
- 309 1 Log in to the CMC Web interface.
- 309 2 The Chassis Status page is displayed. The lower section of Chassis Graphics depicts the rear view of the chassis and contains the health status of all PSUs. PSU health status is indicated by the color of the PSU subgraphic:
- 309 3 Use the cursor to hover over the an individual PSU subgraphic and a corresponding text hint or screen tip is displayed. The text hint provides additional information on that PSU.
- 309 4 The PSU subgraphic is hyperlinked to the corresponding CMC GUI page to provide immediate navigation to the Power Supply Status page for all PSUs.
- 309 1 Log in to the CMC Web interface.
- 309 2 Select Power Supplies in the system tree. The Power Supply Status page displays.
- 309 Table 9-6. Power Supplies
- 309 Item
- 309 Description
- 310 Table 9-7. System Power Status
- 310 Item
- 310 Description
- 311 Using RACADM
- 311 Viewing Power Consumption Status
- 311 Using the Web Interface
- 311 1 Log in to the CMC Web interface.
- 311 2 Select Chassis Overview in the system tree.
- 311 3 Click PowerÆ Power Consumption. The Power Consumption page displays.
- 311 Using RACADM
- 312 Table 9-8. Real-Time Power Statistics
- 312 Item
- 312 Description
- 314 Table 9-9. Real-Time Energy Statistics Status
- 314 Item
- 314 Description
- 314 Table 9-10. System Power Status
- 314 Item
- 314 Description
- 315 Table 9-11. Server Modules
- 315 Item
- 315 Description
- 315 Viewing Power Budget Status
- 315 Using the Web Interface
- 315 1 Log in to the CMC Web interface.
- 315 2 Select Chassis Overview in the system tree.
- 315 3 Click PowerÆ Budget Status.
- 316 Using RACADM
- 316 Table 9-12. System Power Policy Configuration
- 316 Item
- 316 Description
- 318 Table 9-13. Power Budgeting
- 318 Item
- 318 Description
- 319 Table 9-14. Server Modules
- 319 Item
- 319 Description
- 320 Table 9-15. Chassis Power Supplies
- 320 Item
- 320 Description
- 320 Configuring Power Budget and Redundancy
- 320 Using the Web Interface
- 320 1 Log in to the CMC Web interface.
- 320 2 Select Chassis Overview in the system tree.
- 320 3 Click PowerÆ Configuration.
- 320 4 Set any or all of the properties described in Table 9-16 according to your needs.
- 320 5 Click Apply to save your changes.
- 321 Table 9-16. Configurable Power Budget/Redundancy Properties
- 321 Item
- 321 Description
- 323 Using RACADM
- 323 1 Open a serial/Telnet/SSH text console to CMC and log in.
- 323 2 Set properties as needed:
- 324 Assigning Priority Levels to Servers
- 325 Using the Web Interface
- 325 1 Log in to the CMC Web interface.
- 325 2 Select Servers Overview in the system tree. The Servers Status page appears.
- 325 3 Click PowerÆ Server Priority.
- 325 4 Select a priority level (1-9, with 1 holding the highest priority) for one, multiple, or all servers. The default value is 1. You can assign the same priority level to multiple servers.
- 325 5 Click Apply to save your changes.
- 325 Using RACADM
- 325 Setting the Power Budget
- 325 Using the Web Interface
- 325 1 Log in to the CMC Web interface.
- 325 2 Click Chassis Overview in the system tree. The Chassis Health page appears.
- 325 3 Click the Power tab.
- 326 4 Click the Configuration subtab.
- 326 5 Type a budget value of up to 11637 watts in the System Input Power Cap text field.
- 326 6 Click Apply to save your changes.
- 326 Using RACADM
- 327 Server Power Reduction to Maintain Power Budget
- 327 Executing Power Control Operations on the Chassis
- 327 Using the Web Interface
- 327 1 Log in to the CMC Web interface.
- 327 2 Select Chassis Overview in the system tree.
- 327 3 Click the Power tab.
- 327 4 Click the Control subtab.
- 328 5 Click the corresponding radio buttons to select one of the following Power Control Operations:
- 328 6 Click Apply. A dialog box appears requesting confirmation.
- 328 7 Click OK to perform the power management action (for example, cause the system to reset).
- 329 Using RACADM
- 329 Executing Power Control Operations on an IOM
- 329 Using the Web Interface
- 329 1 Log in to the CMC Web interface.
- 329 2 Select I/O Modules Overview.
- 329 3 Click the Power tab.
- 329 4 Select the operation you want to execute (reset or power cycle) from the drop-down menu beside the IOM in the list.
- 329 5 Click Apply.
- 329 6 Click OK to perform the power management action (for example, cause the IOM to power cycle).
- 329 Using RACADM
- 330 Executing Power Control Operations on a Server
- 330 Using the Web Interface
- 330 1 Log in to the CMC Web interface.
- 330 2 Expand Server Overview in the system tree, and then select the server on which you want to execute a power control operation. The Server Status page displays.
- 330 3 Click the Power tab.
- 330 4 Power Status displays the power status of the server (one of the following):
- 330 5 Select one of the following Power Control Operations by clicking its radio button:
- 331 6 Click Apply. A dialog box appears requesting confirmation.
- 331 7 Click OK to perform the power management action (for example, cause the server to reset).
- 331 Using RACADM
- 331 110V Operation
- 332 Troubleshooting
- 333 10
- 333 Using the iKVM Module
- 333 Overview
- 333 iKVM User Interface
- 333 Security
- 333 Scanning
- 334 Server Identification
- 334 Video
- 334 Plug and Play
- 334 FLASH Upgradable
- 334 Physical Connection Interfaces
- 335 iKVM Connection Precedences
- 335 1 Front panel
- 335 2 ACI
- 335 3 Rear Panel
- 335 Tiering Through the ACI Connection
- 336 Using OSCAR
- 336 Navigation Basics
- 336 Table 10-1. OSCAR Keyboard and Mouse Navigation
- 336 Key or Key Sequence
- 336 Result
- 337 Configuring OSCAR
- 337 Table 10-2. OSCAR Setup Menu Features
- 337 Feature
- 337 Purpose
- 337 1 Press <Print Screen> to launch the OSCAR interface. The Main dialog box appears.
- 337 2 Click Setup. The Setup dialog box appears.
- 338 Changing the Display Behavior
- 338 1 Press <Print Screen> to launch OSCAR. The Main dialog box appears.
- 338 2 Click Setup and then Menu. The Menu dialog box appears.
- 338 1 Select Name to display servers alphabetically by name.
- 338 2 Click OK.
- 338 1 Select a key sequence from the Invoke OSCAR menu.
- 338 2 Click OK.
- 338 1 Enter the number of seconds (0 through 9) to delay display of OSCAR after you press <Print Screen>. Entering <0> launches OSCAR with no delay.
- 338 2 Click OK.
- 338 Controlling the Status Flag
- 339 Table 10-3. OSCAR Status Flags
- 339 Flag
- 339 Description
- 339 1 Press <Print Screen>. The Main dialog box appears.
- 339 2 Click Setup and then Flag. The Flag dialog box appears.
- 339 1 Select Displayed to show the flag all the time or Displayed and Timed to display the flag for only five seconds after switching.
- 339 2 Select a flag color from the Display Color section. Options are black, red, blue, and purple.
- 339 3 In Display Mode, select Opaque for a solid color flag or Transparent to see the desktop through the flag.
- 339 4 To position the status flag on the desktop:
- 339 a Click Set Position. The Set Position Flag displays.
- 339 b Left-click on the title bar and drag it to the desired location on the desktop.
- 339 c Right-click to return to the Flag dialog box.
- 339 5 Click OK to save settings.
- 340 Managing Servers With iKVM
- 340 Peripherals Compatibility and Support
- 340 Viewing and Selecting Servers
- 341 Viewing the Status of Your Servers
- 341 Table 10-4. OSCAR Interface Status Symbols
- 341 Symbols
- 341 Description
- 342 Selecting Servers
- 342 Soft Switching
- 343 1 Press <Print Screen> to launch the OSCAR interface. The Main dialog box appears.
- 343 2 Click Setup and then Menu. The Menu dialog box appears.
- 343 3 Select Name or Slot for the Display/Sort Key.
- 343 4 Type the desired delay time in seconds in the Screen Delay Time field.
- 343 5 Click OK.
- 343 Video Connections
- 344 Preemption Warning
- 344 Setting Console Security
- 344 Accessing the Security Dialog Box
- 344 1 Press <Print Screen>. The Main dialog box appears.
- 344 2 Click Setup and the Security. The Security dialog box appears.
- 345 Setting or Changing the Password
- 345 1 Single-click and press <Enter> or double-click in the New field.
- 345 2 Type the new password in the New field and then press <Enter>. Passwords are case sensitive and require 5-12 characters. They must include at least one letter and one number. Legal characters are: A-Z, a-z, 0-9, space, and hyphen.
- 345 3 In the Repeat field, type the password again, and then press <Enter>.
- 345 4 Click OK if you only want to change your password, and then close the dialog box.
- 345 Password-protecting Your Console
- 345 1 Set your password as described in the previous procedure.
- 345 2 Select the Enable Screen Saver box.
- 345 3 Type the number of minutes of Inactivity Time (from 1 through 99) to delay password protection and screen saver activation.
- 345 4 For Mode: If your monitor is ENERGY STAR compliant, select Energy; otherwise select Screen.
- 345 5 Optional: To activate the screen saver test, click Test. The Screen Saver Test dialog box displays. Click OK to start the test.
- 346 Logging In
- 346 1 Press <Print Screen> to launch OSCAR. The Password dialog box appears.
- 346 2 Type your password and then click OK. The Main dialog box appears.
- 346 Setting Automatic Logout
- 346 1 In the Main dialog box, click Setup and then Security.
- 346 2 In the Inactivity Time field, enter the length of time you want to stay connected to a server before it automatically disconnects you.
- 346 3 Click OK.
- 346 Removing Password Protection From Your Console
- 346 1 From the Main dialog box, click Setup and then Security.
- 346 2 In the Security dialog box, single-click and press <Enter>, or double-click in the New field.
- 346 3 Leaving the New field empty, press <Enter>.
- 346 4 Single-click and press <Enter>, or double-click in the Repeat field.
- 346 5 Leaving the Repeat field empty, press <Enter>.
- 346 6 Click OK if you only want to eliminate your password.
- 346 Enabling Screen Saver Mode With No Password Protection
- 346 1 Select Enable Screen Saver.
- 346 2 Type the number of minutes (1 through 99) that you want to delay activation of the screen saver.
- 347 3 Select Energy if your monitor is ENERGY STAR compliant; otherwise select Screen.
- 347 4 Optional: To activate the screen saver test, click Test. The Screen Saver Test dialog box displays. Click OK to start the test.
- 347 Exiting Screen Saver Mode
- 347 1 In the Security dialog box, clear the Enable Screen Saver box.
- 347 2 Click OK.
- 347 Clearing a Lost or Forgotten Password
- 347 1 Log in to the CMC Web interface.
- 347 2 Select iKVM from the Chassis submenu.
- 347 3 Click the Setup tab. The iKVM Configuration page displays.
- 347 4 Click Restore Default Values.
- 348 Changing the Language
- 348 1 Press <Print Screen>. The Main dialog box appears.
- 348 2 Click Setup and then Language. The Language dialog box appears.
- 348 3 Click the radio button for the desired language, and then click OK.
- 348 Displaying Version Information
- 348 1 Press <Print Screen>. The Main dialog box appears.
- 348 2 Click Commands and then Display Versions. The Version dialog box appears.
- 348 3 Click or press <Esc> to close the Version dialog box.
- 348 Scanning Your System
- 349 1 Press <Print Screen>. The Main dialog box appears.
- 349 2 Click Setup and then Scan. The Scan dialog box appears, listing of all servers in the chassis.
- 349 3 Select the box next to the servers you wish to scan.
- 349 4 In the Time field, enter the number of seconds (3 through 99) that you want iKVM to wait before the scan moves to the next server in the sequence.
- 349 5 Click the Add/Remove button, and then click OK.
- 349 1 In the Scan dialog box, select the box next to the server to be removed.
- 349 2 Click the Add/Remove button, and then click OK.
- 349 1 Press <Print Screen>. The Main dialog box appears.
- 349 2 Click Commands. The Command dialog box appears.
- 349 3 Select the Scan Enable box.
- 349 4 Click OK. A message appears indicating that the mouse and keyboard have been reset.
- 349 5 Click to close the message box.
- 350 1 If OSCAR is open and the Main dialog box is displayed, select a server in the list.
- 350 2 Click the Commands button. The Commands dialog box appears.
- 350 3 Clear the Scan Enable box.
- 350 Broadcasting to Servers
- 350 1 Press <Print Screen>. The Main dialog box appears.
- 350 2 Click Setup and then Broadcast. The Broadcast dialog box appears.
- 351 3 Enable mouse and/or keyboard for the servers that are to receive the broadcast commands by selecting the boxes.
- 351 4 Click OK to save the settings and return to the Setup dialog box. Click or press <Escape> to return to the Main dialog box.
- 351 5 Click Commands. The Commands dialog box appears.
- 351 6 Click the Broadcast Enable box to activate broadcasting. The Broadcast Warning dialog box appears.
- 351 7 Click OK to enable the broadcast.
- 351 8 If broadcasting is enabled, type the information and/or perform the mouse movements you want to broadcast from the management station. Only servers in the list are accessible.
- 351 Managing iKVM From CMC
- 351 Enabling or Disabling the Front Panel
- 352 1 Log in to the CMC Web interface.
- 352 2 Select iKVM in the system tree. The iKVM Status page displays.
- 352 3 Click the Setup tab. The iKVM Configuration page displays.
- 352 4 To enable, select the Front Panel USB/Video Enabled check box.
- 352 5 Click Apply to save the setting.
- 352 Enabling the Dell CMC Console Through iKVM
- 352 1 Log in to the CMC Web interface.
- 352 2 Select iKVM in the system tree. The iKVM Status page displays.
- 352 3 Click the Setup tab. The iKVM Configuration page displays.
- 352 4 Select the Allow access to CMC CLI from iKVM check box.
- 352 5 Click Apply to save the setting.
- 352 Viewing the iKVM Status and Properties
- 352 1 Log in to the CMC Web interface.
- 352 2 The Chassis Status page is displayed. The right section of Chassis Graphics depicts the rear view of the chassis and contains the health status of the iKVM. iKVM health status is indicated by the color of the iKVM subgraphic:
- 353 3 Use the cursor to hover over the iKVM subgraphic and a corresponding text hint or screen tip is displayed. The text hint provides additional information on that iKVM.
- 353 4 The iKVM subgraphic is hyperlinked to the corresponding CMC GUI page to provide immediate navigation to the iKVM Status page.
- 353 1 Log in to the CMC Web interface.
- 353 2 Select iKVM in the system tree. The iKVM Status page displays.
- 353 Table 10-5. iKVM Status Information
- 354 Updating the iKVM Firmware
- 354 1 Log in to the CMC Web interface.
- 354 2 Click Chassis in the system tree.
- 354 3 Click the Update tab. The Updatable Components page displays.
- 354 4 Click the iKVM name. The Firmware Update page appears.
- 354 5 In the Firmware Image field, enter the path to the firmware image file on your management station or shared network, or click Browse to navigate to the file location.
- 354 6 Click Begin Firmware Update. A dialog box prompts you to confirm the action.
- 354 7 Click Yes to continue. The Firmware Update Progress section provides firmware update status information. A status indicator di...
- 355 Troubleshooting
- 356 Table 10-6. Troubleshooting iKVM
- 356 Problem
- 356 Likely Cause and Solution
- 356 1 Log in to the CMC Web interface.
- 356 2 Select iKVM in the system tree.
- 356 3 Click the Setup tab.
- 356 4 Select the Front Panel USB/Video Enabled check box.
- 356 5 Click Apply to save the setting.
- 357 1 Log in to the CMC Web interface.
- 357 2 Select iKVM in the system tree.
- 358 1 Log in to the CMC Web interface.
- 358 2 Select iKVM in the system tree.
- 358 3 Click the Setup tab.
- 358 4 Clear (un-check) the Front Panel USB/Video Enabled check box.
- 358 5 Click Apply to save the setting.
- 359 1 Log in to the CMC Web interface.
- 359 2 Select iKVM in the system tree.
- 359 3 Click the Setup tab.
- 359 4 Select the Allow access to CMC CLI from iKVM check box.
- 359 5 Click Apply to save the setting.
- 361 11
- 361 I/O Fabric Management
- 362 Fabric Management
- 362 Figure 11-1. Rear View of a Chassis, Showing the Location of the IOMs
- 363 Invalid Configurations
- 364 Invalid Mezzanine Card (MC) Configuration
- 364 Invalid IOM-Mezzanine Card (MC) Configuration
- 364 Invalid IOM-IOM Configuration
- 364 Fresh Power-up Scenario
- 365 Monitoring IOM Health
- 365 1 Log in to the CMC Web interface.
- 365 2 The Chassis Status page is displayed. The right section of Chassis Graphics depicts the rear view of the chassis and contains the health status for the IOMs. IOM health status is indicated by the color of the IOM subgraphic:
- 365 3 Use the cursor to hover over an individual IOM subgraphic and a corresponding text hint or screen tip is displayed. The text hint provides additional information on that IOM.
- 365 4 The IOM subgraphic is hyperlinked to the corresponding CMC GUI page to provide immediate navigation to the I/O Module Status page associated with that IOM.
- 365 1 Log in to the CMC Web interface.
- 365 2 Select I/O Modules in the Chassis menu in the system tree.
- 365 3 Click the Properties tab.
- 366 4 Click the Status subtab. The I/O Modules Status page displays.
- 366 Table 11-1. I/O Modules Status Information
- 366 Item
- 366 Description
- 368 Viewing the Health Status of an Individual IOM
- 368 1 Log in to the CMC Web interface.
- 368 2 Expand I/O Modules in the system tree. All of the IOMs (1-6) appear in the expanded I/O Modules list.
- 368 3 Click the IOM you want to view in the I/O Modules list in the system tree.
- 368 4 Click the Status subtab. The I/O Modules Status page displays.
- 368 Table 11-2. I/O Module Health Status Information
- 368 Item
- 368 Description
- 370 Configuring Network Settings for an Individual IOM
- 371 1 Log in to the CMC Web interface.
- 371 2 Click I/O Modules in the system tree. Click the Setup subtab. The Configure I/O Modules Network Settings page displays.
- 371 3 To configure network settings for I/O modules, type/select values for the following properties, and then click Apply.
- 371 Table 11-3. Configure I/O Module Network Settings
- 371 Item
- 371 Description
- 373 Troubleshooting IOM Network Settings
- 375 12
- 375 Troubleshooting and Recovery
- 375 Overview
- 375 Chassis Monitoring Tools
- 375 Gathering Configuration information and Chassis Status and Logs
- 376 Usage
- 376 Supported Interfaces
- 376 CLI RACDUMP
- 376 Table 12-1. Subsystems and RACADM Commands
- 377 Usage
- 377 Remote RACDUMP
- 377 Remote RACDUMP Usage
- 378 Telnet RACDUMP
- 378 Configuring LEDs to Identify Components on the Chassis
- 379 Using the Web Interface
- 379 1 Log in to the CMC Web interface.
- 379 2 Click Chassis in the system tree.
- 379 3 Click the Troubleshooting tab.
- 379 4 Click the Identify subtab. The Identify page displays, featuring a list of all components on the chassis.
- 379 5 To enable blinking for a component LED, check the box beside the device name and then click Blink.
- 379 6 To disable blinking for a component LED, check the box beside the device name and then click UnBlink.
- 379 Using RACADM
- 379 Configuring SNMP Alerts
- 380 Table 12-2. Chassis Events That Can Generate SNMP and Email Alerts
- 380 Event
- 380 Description
- 381 Using the Web Interface
- 381 1 Log in to the CMC Web interface.
- 381 2 Select Chassis in the system tree.
- 381 3 Click the Alerts tab. The Chassis Events page appears.
- 381 4 Enable alerting:
- 381 a Select the check boxes of the events for which you want to enable alerting. To enable all events for alerting, select the Select All check box.
- 381 b Click Apply to save your settings.
- 381 5 Click the Traps Settings subtab.The Chassis Event Alert Destinations page displays.
- 382 6 Type a valid address in an empty Destination field.
- 382 7 Type the SNMP Community String to which the destination management station belongs.
- 382 8 Click Apply to save your changes.
- 382 1 Log in to the CMC Web interface.
- 382 2 Select Chassis in the system tree.
- 382 3 Click the Alerts tab. The Chassis Events page displays.
- 382 4 Click the Traps Settings tab. The Chassis Event Alert Destinations page displays.
- 382 5 Click Send in the Test Trap column beside the destination.
- 382 Using RACADM
- 382 1 Open a serial/Telnet/SSH text console to CMC and log in.
- 382 2 Enable alerting by typing:
- 382 3 Specify the events for which you want CMC to generate by typing:
- 383 Table 12-3. Event Traps Filter Masks
- 383 Event
- 383 Filter Mask Value
- 384 4 Enable traps alerting by typing:
- 384 5 Specify a destination IP address to receive the traps alert by typing:
- 384 6 Specify the community name by typing:
- 385 Configuring E-mail Alerts
- 385 Using the Web Interface
- 385 1 Log in to the CMC Web interface.
- 385 2 Select Chassis in the system tree.
- 385 3 Click the Alerts tab. The Chassis Events page appears.
- 385 4 Enable alerting:
- 385 a Select the check boxes of the events for which you want to enable alerting. To enable all events for alerting, select the Select All check box.
- 385 b Click Apply to save your settings.
- 386 5 Click the Email Alert Settings subtab. The Email Alert Destinations page displays.
- 386 6 Specify the SMTP server IP address:
- 386 a Locate the SMTP (Email) Server field, and then type the SMTP hostname or IP address.
- 386 b Enter the desired originator e-mail for the alert, or leave it blank to use the default e-mail originator. The default is cmc@...
- 386 c Click Apply to save your changes.
- 386 7 Specify the e-mail address(es) that receive the alerts:
- 386 a Type a valid e-mail address in an empty Destination Email Address field.
- 386 b Enter an optional Name. This is the name of the entity receiving the e-mail. If a name is entered for an invalid e-mail address, it is ignored.
- 386 c Click Apply to save your settings.
- 387 1 Log in to the CMC Web interface.
- 387 2 Select Chassis in the system tree.
- 387 3 Click the Alerts tab. The Chassis Events page appears.
- 387 4 Click the Email Alert Settings subtab. The Email Alert Destinations page displays.
- 387 5 Click Send in the Destination Email Address column beside the destination.
- 387 Using RACADM
- 387 1 Open a serial/Telnet/SSH text console to CMC and log in.
- 387 2 Enable alerting by typing:
- 387 3 Specify the events for which you want CMC to generate by typing:
- 387 4 Enable e-mail alerting by typing:
- 387 5 Specify a destination e-mail address to receive the e-mail alerts by typing:
- 388 6 Specify the name of the party receiving the e-mail alert by typing:
- 388 7 Setup the SMTP host by configuring the cfgRhostsSmtpServerIpAddr database property by typing:
- 388 First Steps to Troubleshooting a Remote System
- 388 1 Is the system powered on or off?
- 388 2 If powered on, is the operating system functioning, crashed, or just frozen?
- 388 3 If powered off, did the power turn off unexpectedly?
- 389 Monitoring Power and Executing Power Control Commands on the Chassis
- 389 Viewing Power Budget Status
- 389 Executing a Power Control Operation
- 389 Power Troubleshooting
- 392 Viewing Chassis Summaries
- 392 Using the Web Interface
- 392 1 Log in to the CMC Web interface.
- 392 2 Select Chassis in the system tree.
- 392 3 Click the Summary tab. The Chassis Summary page displays.
- 393 Table 12-4. Chassis Summary
- 393 Item
- 393 Description
- 393 Table 12-5. CMC Summary
- 393 Item
- 393 Description
- 393 Active CMC Information
- 395 Standby CMC Information
- 395 Table 12-6. iKVM Summary
- 395 Item
- 395 Description
- 396 Table 12-7. IOM Summary
- 396 Item
- 396 Description
- 396 Using RACADM
- 396 1 Open a serial/Telnet/SSH text console to CMC and log in.
- 396 2 To view chassis and CMC summaries, type:
- 396 3 To view the iKVM summary, type:
- 396 4 To view the IOM summary, type:
- 397 Viewing Chassis and Component Health Status
- 397 Using the Web Interface
- 397 1 Log in to the CMC Web interface.
- 397 2 Select Chassis in the system tree. The Chassis Health page displays.
- 398 Using RACADM
- 398 Viewing the Event Logs
- 398 Viewing the Hardware Log
- 398 Examples of hardware log entries
- 398 Using the Web Interface
- 399 1 Log in to the CMC Web interface.
- 399 2 Click Chassis in the system tree.
- 399 3 Click the Logs tab.
- 399 4 Click the Hardware Log subtab. The Hardware Log page displays.
- 399 1 Click Save Log.
- 399 2 Select a location for a text file of the log.
- 399 Table 12-8. Hardware Log Information
- 399 Item
- 399 Description
- 400 Using RACADM
- 400 1 Open a serial/Telnet/SSH text console to CMC and log in.
- 400 2 To view the hardware log, type:
- 400 Viewing the CMC Log
- 400 Using the Web Interface
- 400 1 Log in to the CMC Web interface.
- 400 2 Click Chassis in the system tree.
- 400 3 Click the Logs tab.
- 401 4 Click the CMC Log subtab. The CMC Log page displays.
- 401 5 To save a copy of the CMC log to your managed station or network, click Save Log.
- 401 Table 12-9. CMC Log Information
- 401 Command
- 401 Result
- 401 Using RACADM
- 401 1 Open a serial/Telnet/SSH text console to CMC and log in.
- 401 2 To view the hardware log, type:
- 401 Using the Diagnostic Console
- 401 1 Log in to the CMC Web interface.
- 401 2 Click Chassis in the system tree.
- 401 3 Click the Troubleshooting tab.
- 401 4 Click the Diagnostics subtab. The Diagnostic Console page displays.
- 402 Table 12-10. Supported Diagnostic Commands
- 402 Command
- 402 Result
- 402 Resetting Components
- 403 1 Log in to the CMC Web interface.
- 403 2 Click Chassis in the system tree.
- 403 3 Click the Troubleshooting tab.
- 403 4 Click the Reset Components subtab. The Reset Components page displays. The CMC Summary section of the Reset Components page displays the following information:
- 403 Table 12-11. CMC Summary
- 403 Attribute
- 403 Description
- 404 5 The Virtual Reseat Server section of the Reset Components page displays the following information:
- 404 Table 12-12. Virtual Reseat Server
- 404 Attribute
- 404 Description
- 405 6 To virtual reseat a server, click the check box of the servers to reseat, and then select Apply Selections. This operation causes the servers to behave as if they were removed and reinserted.
- 405 7 Select Reset/Failover CMC to cause the active CMC to reset. If a standby CMC is present and a chassis is fully redundant, a failover occurs causing the standby CMC to become active.
- 406 Troubleshooting Network Time Protocol (NTP) Errors
- 408 Interpreting LED Colors and Blinking Patterns
- 408 Table 12-13. LED Color and Blinking Patterns
- 408 Component
- 408 LED Color, Blinking Pattern
- 408 Meaning
- 410 Troubleshooting a Non-responsive CMC
- 411 Observing the LEDs to Isolate the Problem
- 411 1 Verify that you have AC present to at least one power supply.
- 411 2 Verify that the CMC card is seated properly. You can release/pull on the ejector handle, remove CMC, reinstall CMC making sure the board is inserted all the way and the latch closes correctly.
- 411 Obtain Recovery Information From the DB-9 Serial Port
- 411 1 Install a NULL modem cable between CMC and a client machine.
- 411 2 Open a terminal emulator of your choice (such as HyperTerminal or Minicom). Set up: 8 bits, no parity, no flow control, baud rate 115200.
- 411 3 Press <Enter>. If a recovery prompt appears, additional information is available. The prompt indicates the CMC slot number and failure type.
- 412 Recovering the Firmware Image
- 413 Troubleshooting Network Problems
- 413 Resetting Forgotten Administrator Password
- 414 1 Press in the CMC release latch on the handle and move the handle away from the module front panel. Slide the CMC module out of the enclosure.
- 414 2 Remove the jumper plug from the password reset connector, and insert a 2-pin jumper to enable the default administrator account. See Figure 12-1 to locate the password jumper on the CMC board.
- 415 Figure 12-1. Password Reset Jumper Location
- 415 Table 12-14. CMC Password Jumper Settings
- 415 3 Slide the CMC module into the enclosure. Reattach any cables that were disconnected.
- 416 4 If the jumpered CMC module is the only CMC, then simply wait for it to finish rebooting. If you have redundant CMCs in your chassis, then initiate a changeover to make the jumpered CMC module active. On the GUI interface:
- 416 a Navigate to the Chassis page, click the Power tabÆ Control subtab.
- 416 b Select the Reset CMC (warm boot) button.
- 416 c Click Apply.
- 416 5 Log into the active CMC using the default administrator username:root and password: calvin, and restore any necessary user account settings. The existing accounts and passwords are not disabled and are still active.
- 416 6 Perform any needed management actions, including creating a new administrator password in place of the forgotten one.
- 416 7 Remove the 2-pin PASSWORD_RST jumper and replace the jumper plug.
- 416 a Press in the CMC release latch on the handle and move the handle away from the module front panel. Slide the CMC module out of the enclosure.
- 416 b Remove the 2-pin jumper and replace the jumper plug.
- 416 c Slide the CMC module into the enclosure. Reattach any cables that were disconnected. Repeat step 4 to make the unjumpered CMC module the active CMC.
- 416 Troubleshooting Alerting
- 417 13
- 417 Diagnostics
- 417 Using the LCD Panel Interface
- 417 LCD Navigation
- 418 Table 13-1. LCD Panel Navigational Icons
- 418 or
- 418 Main Menu
- 418 1 Use the up and down arrow buttons to highlight an item.
- 418 2 Press the center button to activate your selection.
- 419 LCD Setup Menu
- 419 1 Use the up and down arrow buttons to highlight an item in the menu or highlight the Back icon if you want to return to the Main menu.
- 419 2 Press the center button to activate your selection.
- 419 Language Setup Screen
- 419 1 Use the up, down, left, and right arrow buttons to highlight the desired language.
- 419 2 Press the center button. The Accept icon appears and is highlighted.
- 419 3 Press the center button to confirm the change. The LCD Setup menu is displayed.
- 419 Default Screen
- 420 1 Use the up and down arrow buttons to highlight the screen you want to set to the default.
- 420 2 Press the center button. The Accept icon is highlighted.
- 420 3 Press the center button again to confirm the change. The Default Screen is displayed.
- 420 Graphical Server Status Screen
- 420 1 Highlight the rotate icon.
- 420 2 Press the center button.
- 420 1 Use the arrow buttons to highlight the desired server.
- 420 2 Press the center button. The Server Status screen displays.
- 420 1 Use the arrow buttons to highlight the Back icon.
- 420 2 Press the center button.
- 421 Graphical Module Status Screen
- 421 1 Highlight the rotate icon.
- 421 2 Press the center button.
- 421 1 Use the up, down, left, and right arrow buttons to highlight the desired module.
- 421 2 Press the center button. The Module Status screen displays.
- 421 1 Use the arrow buttons to highlight the Back icon.
- 421 2 Press the center button. The Main Menu displays.
- 421 Enclosure Menu Screen
- 421 1 Use the navigation buttons to highlight the desired item. (Highlight the Back icon to return to the Main Menu.)
- 421 2 Press the center button. The selected screen displays.
- 422 Module Status Screen
- 422 Enclosure Status Screen
- 422 IP Summary Screen
- 423 Diagnostics
- 423 LCD Hardware Troubleshooting
- 424 Figure 13-1. Removing and Installing the LCD Module
- 425 Table 13-2. LCD Hardware Trouble Shooting Items
- 426 Front Panel LCD Messages
- 426 LCD Error Messages
- 426 Table 13-3. CMC Status Screens
- 427 Table 13-4. Enclosure/Chassis Status Screen
- 428 Table 13-5. Fan Status Screens
- 428 Table 13-6. IOM Status Screens
- 428 Table 13-7. iKVM Status Screen
- 429 Table 13-8. PSU Status Screens
- 429 Table 13-9. Server Status Screen
- 433 LCD Module and Server Status Information
- 433 Table 13-10. CMC Status
- 434 Table 13-11. Chassis/Enclosure Status
- 435 Table 13-12. Fan Status
- 435 Table 13-13. PSU Status
- 435 Table 13-14. IOM Status
- 436 Table 13-15. iKVM Status
- 436 Table 13-16. Server Status