Contents. Dell Chassis Management Controller Version 3.1

Add to My manuals
442 Pages

advertisement

Contents. Dell Chassis Management Controller Version 3.1 | Manualzz

Contents

1 Overview

. . . . . . . . . . . . . . . . . . . . . . . . .

19

What’s New For This Release

. . . . . . . . . . . . . .

19

CMC Management Features

. . . . . . . . . . . . . . .

20

Security Features

. . . . . . . . . . . . . . . . . . . .

21

Chassis Overview

. . . . . . . . . . . . . . . . . . . .

22

Hardware Specifications

. . . . . . . . . . . . . . . .

23

TCP/IP Ports . . . . . . . . . . . . . . . . . . . .

23

Supported Remote Access Connections

. . . . . . . .

24

Supported Platforms

. . . . . . . . . . . . . . . . . . .

24

Supported Web Browsers

. . . . . . . . . . . . . . . .

25

Supported Management Console

Applications

. . . . . . . . . . . . . . . . . . . . . . .

25

WS-Management Support

. . . . . . . . . . . . . . . .

25

Other Documents You May Need

. . . . . . . . . . . .

27

2 Installing and Setting Up the CMC

. . . . .

29

Before You Begin

. . . . . . . . . . . . . . . . . . . .

29

Installing the CMC Hardware

. . . . . . . . . . . . . .

29

Checklist for Integration of a Chassis

. . . . . . .

30

Contents 3

4 Contents

Basic CMC Network Connection . . . . . . . . . .

30

Daisy-chain CMC Network Connection . . . . . .

31

Installing Remote Access Software on a

Management Station

. . . . . . . . . . . . . . . . . . .

35

Installing RACADM on a

Linux Management Station . . . . . . . . . . . . .

35

Uninstalling RACADM From a

Linux Management Station . . . . . . . . . . . . .

36

Configuring a Web Browser

. . . . . . . . . . . . . . .

36

Proxy Server

. . . . . . . . . . . . . . . . . . . .

37

Microsoft Phishing Filter

. . . . . . . . . . . . . .

38

Certificate Revocation List (CRL)

Fetching . . . . . . . . . . . . . . . . . . . . . . .

38

Downloading Files From CMC With

Internet Explorer . . . . . . . . . . . . . . . . . .

39

Allow Animations in Internet Explorer

. . . . . . .

39

Setting Up Initial Access to the CMC

. . . . . . . . . .

39

Configuring the CMC Network . . . . . . . . . . .

40

Configuring Networking Using the

LCD Configuration Wizard

. . . . . . . . . . . . .

41

Accessing the CMC Through a Network

. . . . . . . .

48

Installing or Updating the CMC Firmware

. . . . . . . .

49

Downloading the CMC Firmware . . . . . . . . . .

49

Updating CMC Firmware Using the

Web Interface

. . . . . . . . . . . . . . . . . . . .

50

Updating the CMC Firmware Using

RACADM . . . . . . . . . . . . . . . . . . . . . .

50

Configuring CMC Properties

. . . . . . . . . . . . . . .

51

Configuring Power Budgeting . . . . . . . . . . .

51

Configuring CMC Network Settings

. . . . . . . .

51

Adding and Configuring Users

. . . . . . . . . . .

52

Adding SNMP and E-mail Alerts . . . . . . . . . .

52

Configuring Remote Syslog . . . . . . . . . . . . .

52

Understanding the Redundant CMC Environment

. . . .

53

About the Standby CMC

. . . . . . . . . . . . . .

53

Active CMC Election Process

. . . . . . . . . . .

54

Obtaining Health Status of

Redundant CMC . . . . . . . . . . . . . . . . . .

54

3 Configuring CMC to Use Command

Line Consoles

. . . . . . . . . . . . . . . . . . . . .

55

Command Line Console Features on the CMC

. . . . .

55

Using a Serial, Telnet, or SSH Console

. . . . . . . . .

56

Using a Telnet Console With the CMC

. . . . . . . . .

56

Using SSH With the CMC

. . . . . . . . . . . . . . . .

56

Enabling SSH on the CMC . . . . . . . . . . . . .

57

Changing the SSH Port . . . . . . . . . . . . . . .

57

Enabling the Front Panel to iKVM Connection

. . . . . . . . . . . . . . . . . .

58

Configuring Terminal Emulation Software

. . . . . . .

59

Configuring Linux Minicom . . . . . . . . . . . . .

59

Connecting to Servers or I/O Modules With the Connect Command

. . . . . . . . . . . . . . . . . .

61

Configuring the Managed Server BIOS for Serial Console Redirection

. . . . . . . . . . .

62

Configuring Windows for Serial

Console Redirection . . . . . . . . . . . . . . . .

63

Configuring Linux for Server Serial

Console Redirection During Boot

. . . . . . . . . .

63

Configuring Linux for Server Serial

Console Redirection After Boot . . . . . . . . . .

65

Contents 5

6

4 Using the RACADM Command

Line Interface

. . . . . . . . . . . . . . . . . . . . .

69

Using a Serial, Telnet, or SSH Console

. . . . . . . . .

69

Logging in to the CMC . . . . . . . . . . . . . . .

70

Starting a Text Console . . . . . . . . . . . . . . .

70

Using RACADM

. . . . . . . . . . . . . . . . . . . . . .

70

RACADM Subcommands

. . . . . . . . . . . . . .

71

Accessing RACADM Remotely

. . . . . . . . . . .

74

Enabling and Disabling the RACADM

Remote Capability . . . . . . . . . . . . . . . . . .

76

Using RACADM Remotely . . . . . . . . . . . . . .

76

RACADM Error Messages . . . . . . . . . . . . .

77

Using RACADM to Configure the CMC

. . . . . . . . . .

78

Configuring CMC Network Properties

. . . . . . . . . .

78

Setting Up Initial Access to the CMC

. . . . . . . .

78

Viewing Current Network Settings

. . . . . . . . .

79

Configuring the Network LAN Settings . . . . . . .

80

Configuring the Network Security

Settings (IPv4 Only) . . . . . . . . . . . . . . . . .

86

Using RACADM to Configure Users

. . . . . . . . . . .

87

Before You Begin

. . . . . . . . . . . . . . . . . .

87

Adding a CMC User

. . . . . . . . . . . . . . . . .

88

Using RACADM to Configure Public Key

Authentication over SSH

. . . . . . . . . . . . . . . . .

89

Before You Begin

. . . . . . . . . . . . . . . . . .

89

Generating Public Keys for Windows . . . . . . . .

90

Generating Public Keys for Linux

. . . . . . . . . .

91

RACADM Syntax Notes for CMC

. . . . . . . . . .

91

Viewing the Public Keys . . . . . . . . . . . . . .

91

Adding the Public Keys

. . . . . . . . . . . . . . .

92

Contents

Deleting the Public Keys . . . . . . . . . . . . . .

92

Logging in Using Public

Key Authentication . . . . . . . . . . . . . . . . .

92

Enabling a CMC User With Permissions

. . . . . .

93

Disabling a CMC User

. . . . . . . . . . . . . . .

93

Configuring SNMP and E-mail Alerting

. . . . . . . . .

94

Configuring Multiple CMCs in

Multiple Chassis

. . . . . . . . . . . . . . . . . . . . .

94

Creating a CMC Configuration File

. . . . . . . . .

95

Parsing Rules

. . . . . . . . . . . . . . . . . . . .

97

Modifying the CMC IP Address . . . . . . . . . . .

99

Using RACADM to Configure Properties on iDRAC

. . . . . . . . . . . . . . . . . . . . . . . . .

100

Troubleshooting

. . . . . . . . . . . . . . . . . . . . .

101

5 Using the CMC Web Interface

. . . . . . . .

103

Accessing the CMC Web Interface

. . . . . . . . . . .

103

Logging In . . . . . . . . . . . . . . . . . . . . . .

104

Logging Out . . . . . . . . . . . . . . . . . . . . .

105

Configuring Basic CMC Settings

. . . . . . . . . . . .

105

Setting the Chassis Name

. . . . . . . . . . . . .

105

Setting the Date and Time on CMC

. . . . . . . . .

106

Chassis Health Page

. . . . . . . . . . . . . . . . . . .

106

Using Chassis Group

. . . . . . . . . . . . . . . . . . .

107

Chassis Group Features . . . . . . . . . . . . . .

107

Setting up a Chassis Group . . . . . . . . . . . . .

108

Removing a Member from the Leader . . . . . . .

109

Disbanding a Chassis Group . . . . . . . . . . . .

109

Contents 7

8 Contents

Disabling an Individual Member at the

Member Chassis

. . . . . . . . . . . . . . . . .

110

Chassis Component Summary

. . . . . . . . . . . . .

110

Chassis Graphics . . . . . . . . . . . . . . . . .

110

Chassis Health . . . . . . . . . . . . . . . . . .

112

Selected Component Information

. . . . . . . . . . .

113

Monitoring System Health Status

. . . . . . . . . . .

119

Viewing Chassis and Component

Summaries . . . . . . . . . . . . . . . . . . . .

119

Viewing Power Budget Status . . . . . . . . . .

120

Viewing Server Model Name and

Service Tag

. . . . . . . . . . . . . . . . . . . .

120

Viewing the Health Status of

All Servers . . . . . . . . . . . . . . . . . . . .

120

Editing Slot Names . . . . . . . . . . . . . . . .

124

Using Server’s Host Name as the

Slot Name . . . . . . . . . . . . . . . . . . . . .

125

Setting the First Boot Device for

Servers . . . . . . . . . . . . . . . . . . . . . .

125

Viewing the Health Status of an

Individual Server

. . . . . . . . . . . . . . . . .

127

Viewing the Health Status of IOMs

. . . . . . . .

132

Viewing the Health Status of the Fans . . . . . .

133

Viewing the iKVM Status

. . . . . . . . . . . . .

135

Viewing the Health Status of the PSUs

. . . . . .

137

Viewing Status of the Temperature

Sensors . . . . . . . . . . . . . . . . . . . . . .

139

Viewing the LCD Status

. . . . . . . . . . . . . . . .

140

Viewing World Wide Name/Media Access

Control (WWN/MAC) IDs

. . . . . . . . . . . . . . . .

141

Fabric Configuration . . . . . . . . . . . . . . .

141

WWN/MAC Addresses . . . . . . . . . . . . . .

142

Configuring CMC Network Properties

. . . . . . . . .

142

Setting Up Initial Access to CMC

. . . . . . . . . .

142

Configuring the Network LAN Settings

. . . . . . .

143

Configuring CMC Network

Security Settings . . . . . . . . . . . . . . . . . .

151

Configuring VLAN

. . . . . . . . . . . . . . . . . . . .

153

Adding and Configuring CMC Users

. . . . . . . . . . .

154

User Types

. . . . . . . . . . . . . . . . . . . . .

154

Adding and Managing Users . . . . . . . . . . . .

160

Configuring and Managing Microsoft Active

Directory Certificates

. . . . . . . . . . . . . . . . . .

163

Common Settings . . . . . . . . . . . . . . . . . .

163

Standard Schema Settings

. . . . . . . . . . . . .

167

Extended Schema Settings

. . . . . . . . . . . . .

167

Managing Active Directory Certificates

. . . . . . . .

168

Kerberos Keytab

. . . . . . . . . . . . . . . . . . . . .

169

Configuring and Managing Generic Lightweight

Directory Access Protocol Services

. . . . . . . . . .

169

Selecting Your LDAP Servers

. . . . . . . . . . . . . .

171

Managing LDAP Group Settings

. . . . . . . . . . . . .

172

Managing LDAP Security Certificates

. . . . . . . . .

172

Securing CMC Communications Using SSL and

Digital Certificates

. . . . . . . . . . . . . . . . . . . .

173

Secure Sockets Layer (SSL) . . . . . . . . . . . .

173

Certificate Signing Request (CSR) . . . . . . . . .

174

Accessing the SSL Main Menu . . . . . . . . . .

174

Generating a New Certificate

Signing Request

. . . . . . . . . . . . . . . . . .

175

Contents 9

10 Contents

Uploading a Server Certificate . . . . . . . . . .

178

Uploading Webserver Key and

Certificate . . . . . . . . . . . . . . . . . . . . .

178

Viewing a Server Certificate

. . . . . . . . . . .

179

Managing Sessions

. . . . . . . . . . . . . . . . . .

179

Configuring Services

. . . . . . . . . . . . . . . . . .

180

Configuring Power Budgeting

. . . . . . . . . . . . .

188

Managing Firmware Updates

. . . . . . . . . . . . .

189

Viewing the Current Firmware Versions . . . . .

189

Updating Firmware . . . . . . . . . . . . . . . .

190

Recovering iDRAC Firmware

Using CMC . . . . . . . . . . . . . . . . . . . .

195

Managing iDRAC

. . . . . . . . . . . . . . . . . . . .

196

iDRAC QuickDeploy . . . . . . . . . . . . . . . .

196

iDRAC Network Settings . . . . . . . . . . . . .

200

Launching Remote Console from

CMC GUI

. . . . . . . . . . . . . . . . . . . . .

202

Launching iDRAC using Single

Sign-On . . . . . . . . . . . . . . . . . . . . . .

203

FlexAddress

. . . . . . . . . . . . . . . . . . . . . .

205

Viewing FlexAddress Status . . . . . . . . . . .

205

Configuring FlexAddress

. . . . . . . . . . . . .

209

Chassis-Level Fabric and Slot

FlexAddress Configuration . . . . . . . . . . . .

209

Server-Level Slot FlexAddress

Configuration

. . . . . . . . . . . . . . . . . . .

210

Remote File Sharing

. . . . . . . . . . . . . . . . . .

211

Frequently Asked Questions

. . . . . . . . . . . . . .

213

Troubleshooting CMC

. . . . . . . . . . . . . . . . .

215

6 Using FlexAddress

. . . . . . . . . . . . . . . . .

217

Activating FlexAddress

. . . . . . . . . . . . . . . . .

218

Verifying FlexAddress Activation . . . . . . . . . .

220

Deactivating FlexAddress

. . . . . . . . . . . . . . . .

221

Deactivating FlexAddress

. . . . . . . . . . . . .

222

Configuring FlexAddress Using the CLI

. . . . . . . . .

222

Additional FlexAddress Configuration for Linux

. . . . . . . . . . . . . . . . . . . . . . .

223

Viewing FlexAddress Status Using the CLI

. . . . . . .

223

Configuring FlexAddress Using the GUI

. . . . . . . . .

224

Wake-On-LAN with FlexAddress . . . . . . . . . .

224

Troubleshooting FlexAddress

. . . . . . . . . . . . . .

224

Command Messages

. . . . . . . . . . . . . . . . . . .

228

FlexAddress DELL SOFTWARE

LICENSE AGREEMENT

. . . . . . . . . . . . . . . . . .

231

7 Using FlexAddress Plus

. . . . . . . . . . . . .

235

Activating FlexAddress Plus

. . . . . . . . . . . . . .

235

FlexAddress vs FlexAddress Plus

. . . . . . . . . . . .

236

Scheme 1 and Scheme 2 MAC

Address Allocation

. . . . . . . . . . . . . . . . . . .

237

8 Using the CMC Directory Service

. . . . .

241

Using CMC with Microsoft Active Directory

. . . . . .

241

Active Directory Schema Extensions

. . . . . . .

241

Contents 11

12 Contents

Standard Schema Versus Extended

Schema

. . . . . . . . . . . . . . . . . . . . . .

241

Standard Schema Active Directory Overview

. . . . .

242

Configuring Standard Schema

Active Directory to Access CMC

. . . . . . . . .

244

Configuring CMC With Standard Schema

Active Directory and Web Interface . . . . . . .

244

Configuring CMC With Standard Schema

Active Directory and RACADM . . . . . . . . . .

247

Extended Schema Overview

. . . . . . . . . . . . . .

248

Active Directory Schema Extensions . . . . . . .

248

Overview of the RAC Schema Extensions . . . .

249

Active Directory Object Overview . . . . . . . .

249

Configuring Extended Schema

Active Directory to Access Your CMC . . . . . .

254

Extending the Active Directory Schema

. . . . .

254

Installing the Dell Extension to the

Active Directory Users and

Computers Snap-In

. . . . . . . . . . . . . . . .

261

Adding CMC Users and Privileges to

Active Directory . . . . . . . . . . . . . . . . . .

262

Configuring CMC With Extended Schema

Active Directory and the Web Interface

. . . . .

264

Configuring CMC With Extended Schema

Active Directory and RACADM . . . . . . . . . .

267

Frequently Asked Questions . . . . . . . . . . .

269

Configuring Single Sign-On

. . . . . . . . . . . . . .

272

System Requirements

. . . . . . . . . . . . . . .

272

Configuring Settings

. . . . . . . . . . . . . . .

273

Configuring Active Directory . . . . . . . . . . .

273

Configuring CMC

. . . . . . . . . . . . . . . . .

274

Uploading the Kerberos Keytab File

. . . . . . .

274

Enabling Single Sign-On . . . . . . . . . . . . .

275

Configuring the Browser For

Single Sign-On Login

. . . . . . . . . . . . . . . .

276

Logging into CMC Using Single Sign-On . . . . . .

277

Configuring Smart Card Two-Factor

Authentication

. . . . . . . . . . . . . . . . . . . . . .

278

System Requirements . . . . . . . . . . . . . . . .

278

Configuring Settings

. . . . . . . . . . . . . . . .

278

Configuring Active Directory

. . . . . . . . . . . .

279

Configuring CMC . . . . . . . . . . . . . . . . . .

279

Uploading the Kerberos Keytab File

. . . . . . . .

279

Enabling Smart Card Authentication

. . . . . . . .

280

Configuring the Browser For

Smart Card Login . . . . . . . . . . . . . . . . . .

280

Logging into CMC Using Smart Card . . . . . . . .

281

Troubleshooting the Smart Card Login . . . . . . .

281

Using CMC with Generic LDAP

. . . . . . . . . . . . .

282

Configuring the Generic LDAP Directory to Access CMC . . . . . . . . . . . . . . . . . . .

283

Configuring Generic LDAP Directory

Service Using CMC Web-Based Interface

. . . . .

284

Selecting Your LDAP Servers . . . . . . . . . . . .

286

Managing LDAP Group Settings

. . . . . . . . . .

287

Managing LDAP Security Certificates

. . . . . . .

287

Configuring Generic LDAP Directory

Service Using RACADM . . . . . . . . . . . . . .

288

Usage . . . . . . . . . . . . . . . . . . . . . . . .

288

Getting Help . . . . . . . . . . . . . . . . . . . . .

288

9 Power Management

. . . . . . . . . . . . . . .

289

Overview

. . . . . . . . . . . . . . . . . . . . . . . . .

289

AC Redundancy Mode . . . . . . . . . . . . . . .

289

Power Supply Redundancy Mode . . . . . . . . .

291

Contents 13

14 Contents

No Redundancy Mode . . . . . . . . . . . . . .

292

Power Budgeting for Hardware Modules . . . .

293

Server Slot Power Priority Settings . . . . . . . .

295

Dynamic Power Supply Engagement . . . . . . .

296

Redundancy Policies

. . . . . . . . . . . . . . . . . .

298

AC Redundancy . . . . . . . . . . . . . . . . . .

298

Power Supply Redundancy

. . . . . . . . . . . .

298

No Redundancy

. . . . . . . . . . . . . . . . . .

299

Power Conservation and Power

Budget Changes . . . . . . . . . . . . . . . . .

299

Power Supply and Redundancy Policy

Changes in System Event Log . . . . . . . . . . .

306

Redundancy Status and Overall

Power Health . . . . . . . . . . . . . . . . . . .

308

Configuring and Managing Power

. . . . . . . . . . .

308

Viewing the Health Status of the PSUs

. . . . . .

308

Viewing Power Consumption Status

. . . . . . .

311

Viewing Power Budget Status . . . . . . . . . .

315

Configuring Power Budget and Redundancy . . . . . . . . . . . . . . . . .

320

Assigning Priority Levels to Servers . . . . . . .

324

Setting the Power Budget . . . . . . . . . . . .

325

Server Power Reduction to

Maintain Power Budget . . . . . . . . . . . . . .

327

Executing Power Control Operations on the Chassis . . . . . . . . . . . . . . . . . .

327

Executing Power Control Operations on an IOM

. . . . . . . . . . . . . . . . . . . . .

329

Executing Power Control Operations on a Server . . . . . . . . . . . . . . . . . . . .

330

Troubleshooting . . . . . . . . . . . . . . . . . .

332

10 Using the iKVM Module

. . . . . . . . . . . . .

333

Overview

. . . . . . . . . . . . . . . . . . . . . . . . .

333

iKVM User Interface . . . . . . . . . . . . . . . .

333

Security . . . . . . . . . . . . . . . . . . . . . . .

333

Scanning . . . . . . . . . . . . . . . . . . . . . .

333

Server Identification . . . . . . . . . . . . . . . .

334

Video . . . . . . . . . . . . . . . . . . . . . . . .

334

Plug and Play . . . . . . . . . . . . . . . . . . . .

334

FLASH Upgradable . . . . . . . . . . . . . . . . .

334

Physical Connection Interfaces

. . . . . . . . . . . . .

334

iKVM Connection Precedences

. . . . . . . . . .

335

Tiering Through the ACI Connection . . . . . . . .

335

Using OSCAR

. . . . . . . . . . . . . . . . . . . . . . .

336

Navigation Basics . . . . . . . . . . . . . . . . .

336

Configuring OSCAR . . . . . . . . . . . . . . . . .

337

Managing Servers With iKVM

. . . . . . . . . . . . . .

340

Peripherals Compatibility and Support

. . . . . . .

340

Viewing and Selecting Servers . . . . . . . . . . .

340

Setting Console Security

. . . . . . . . . . . . . .

344

Scanning Your System

. . . . . . . . . . . . . . .

348

Broadcasting to Servers . . . . . . . . . . . . . .

350

Managing iKVM From CMC

. . . . . . . . . . . . . . .

351

Enabling or Disabling the Front Panel . . . . . . .

351

Enabling the Dell CMC Console

Through iKVM

. . . . . . . . . . . . . . . . . . .

352

Viewing the iKVM Status and Properties

. . . . . .

352

Updating the iKVM Firmware . . . . . . . . . . . .

354

Troubleshooting

. . . . . . . . . . . . . . . . . . . . .

355

Contents 15

16

11 I/O Fabric Management

. . . . . . . . . . . . .

361

Fabric Management

. . . . . . . . . . . . . . . . . .

362

Invalid Configurations

. . . . . . . . . . . . . . . . .

363

Invalid Mezzanine Card (MC)

Configuration . . . . . . . . . . . . . . . . . . .

364

Invalid IOM-Mezzanine Card (MC)

Configuration . . . . . . . . . . . . . . . . . . .

364

Invalid IOM-IOM Configuration . . . . . . . . . .

364

Fresh Power-up Scenario

. . . . . . . . . . . . . . .

364

Monitoring IOM Health

. . . . . . . . . . . . . . . .

365

Viewing the Health Status of an

Individual IOM . . . . . . . . . . . . . . . . . .

368

Configuring Network Settings for an

Individual IOM

. . . . . . . . . . . . . . . . . .

370

Troubleshooting IOM Network Settings

. . . . .

373

12 Troubleshooting and Recovery

. . . . . . .

375

Overview

. . . . . . . . . . . . . . . . . . . . . . . .

375

Chassis Monitoring Tools

. . . . . . . . . . . . . . .

375

Gathering Configuration information and

Chassis Status and Logs . . . . . . . . . . . . .

375

Usage . . . . . . . . . . . . . . . . . . . . . . .

376

Supported Interfaces . . . . . . . . . . . . . . .

376

CLI RACDUMP . . . . . . . . . . . . . . . . . .

376

Remote RACDUMP . . . . . . . . . . . . . . . .

377

Remote RACDUMP Usage . . . . . . . . . . . .

377

Telnet RACDUMP . . . . . . . . . . . . . . . . .

378

Configuring LEDs to Identify Components on the Chassis . . . . . . . . . . . . . . . . . .

378

Configuring SNMP Alerts

. . . . . . . . . . . . .

379

Contents

Configuring E-mail Alerts . . . . . . . . . . . . . .

385

First Steps to Troubleshooting a Remote System

. . . .

388

Monitoring Power and Executing Power

Control Commands on the Chassis

. . . . . . . . . . .

389

Viewing Power Budget Status . . . . . . . . . . .

389

Executing a Power Control Operation . . . . . . .

389

Power Troubleshooting

. . . . . . . . . . . . . . . . .

389

Viewing Chassis Summaries

. . . . . . . . . . . . . .

392

Viewing Chassis and Component

Health Status

. . . . . . . . . . . . . . . . . . . . . . .

397

Viewing the Event Logs

. . . . . . . . . . . . . . . . .

398

Viewing the Hardware Log . . . . . . . . . . . . .

398

Viewing the CMC Log . . . . . . . . . . . . . . . .

400

Using the Diagnostic Console

. . . . . . . . . . . . . .

401

Resetting Components

. . . . . . . . . . . . . . . . . .

402

Troubleshooting Network Time Protocol

(NTP) Errors

. . . . . . . . . . . . . . . . . . . . . . .

406

Interpreting LED Colors and Blinking Patterns

. . . . .

408

Troubleshooting a Non-responsive CMC

. . . . . . . .

410

Observing the LEDs to Isolate the Problem

. . . . . . . . . . . . . . . . . . . . .

411

Obtain Recovery Information From the DB-9 Serial Port . . . . . . . . . . . . . . . .

411

Recovering the Firmware Image . . . . . . . . . .

412

Troubleshooting Network Problems

. . . . . . . . . .

413

Resetting Forgotten Administrator Password

. . . . . .

413

Contents 17

Troubleshooting Alerting

. . . . . . . . . . . . . . .

416

13 Diagnostics

. . . . . . . . . . . . . . . . . . . . . .

417

Using the LCD Panel Interface

. . . . . . . . . . . . .

417

LCD Navigation

. . . . . . . . . . . . . . . . . . . . .

417

Main Menu . . . . . . . . . . . . . . . . . . . .

418

LCD Setup Menu . . . . . . . . . . . . . . . . .

419

Language Setup Screen . . . . . . . . . . . . .

419

Default Screen . . . . . . . . . . . . . . . . . .

419

Graphical Server Status Screen . . . . . . . . .

420

Graphical Module Status Screen . . . . . . . . .

421

Enclosure Menu Screen . . . . . . . . . . . . .

421

Module Status Screen . . . . . . . . . . . . . .

422

Enclosure Status Screen . . . . . . . . . . . . .

422

IP Summary Screen . . . . . . . . . . . . . . . .

422

Diagnostics

. . . . . . . . . . . . . . . . . . . . . . .

423

LCD Hardware Troubleshooting

. . . . . . . . . . . .

423

Front Panel LCD Messages

. . . . . . . . . . . . . .

426

LCD Error Messages

. . . . . . . . . . . . . . . . . .

426

LCD Module and Server Status Information

. . . . . .

433

Index

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

439

18 Contents

advertisement

Key Features

  • Comprehensive hardware management for PowerEdge rack servers
  • Secure end-to-end management with advanced security features
  • Remote management capabilities for in-band and out-of-band access
  • User-friendly web interface and industry-standard CLI for easy management
  • Support for industry-standard protocols such as SNMP, IPMI, and Redfish
  • Integration with Dell OpenManage Enterprise management console for centralized management

Related manuals

Frequently Answers and Questions

What are the benefits of using the Dell Chassis Management Controller?
The Dell Chassis Management Controller provides several benefits, including improved server uptime and performance, reduced IT costs, and enhanced security.
What are the key features of the Dell Chassis Management Controller?
The key features of the Dell Chassis Management Controller include comprehensive hardware management, secure end-to-end management, remote management capabilities, and an intuitive user interface.
How do I access the Dell Chassis Management Controller?
You can access the Dell Chassis Management Controller through the web interface, CLI, or industry-standard protocols such as SNMP, IPMI, and Redfish.
What are the security features of the Dell Chassis Management Controller?
The Dell Chassis Management Controller includes advanced security features such as role-based access control, authentication, and encryption to protect your servers from unauthorized access and malicious threats.
Can I use the Dell Chassis Management Controller to manage servers from different manufacturers?
No, the Dell Chassis Management Controller is designed to manage Dell PowerEdge rack servers only.
Download PDF

advertisement

Table of contents