Dell PowerEdge R810 server Panduan ringkas

Add to My manuals
70 Pages

advertisement

Dell PowerEdge R810 server Panduan ringkas | Manualzz

Dell™ PowerEdge™

R810 Systems

Getting Started

With Your System

系统使用入门

Memulai Dengan Sistem Anda

はじめに

시스템시작하기

Regulatory Model E05S Series

Dell™ PowerEdge™

R810 Systems

Getting Started

With Your System

Notes, Cautions, and Warnings

NOTE:

A NOTE indicates important information that helps you make better use of your computer.

CAUTION:

A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed.

WARNING:

A WARNING indicates a potential for property damage, personal injury, or death.

____________________

Information in this document is subject to change without notice.

© 2009 Dell Inc. All rights reserved.

Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.

Trademarks used in this text: Dell , the DELL logo and PowerEdge are trademarks of Dell Inc.;

Intel and Xeon are registered trademarks of Intel Corporation in the U.S. and other countries;

Microsoft , Windows , Windows Server and Hyper-V are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries; SUSE is a registered trademark of Novell, Inc. in the United States and other countries; Citrix and XenServer are trademarks of Citrix Systems, Inc. and/or more of its subsidiaries, and may be registered in the United States

Patent and Trademark Office and in other countries; VMware is a registered trademark or trademark

(the “Marks”) of VMware, Inc. in the United States and/or other jurisdictions; Solaris is a trademark of Sun Microsystems, Inc. in the United States and other countries.

Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.

Regulatory Model E05S Series

November 2009 P/N X917M Rev. A00

Installation and Configuration

WARNING:

Before performing the following procedure, review the safety instructions that came with the system.

Unpacking the System

Unpack your system and identify each item.

Installing the Rails and System in a Rack

Assemble the rails and install the system in the rack following the safety instructions and the rack installation instructions provided with your system.

Getting Started With Your System

3

Optional – Connecting the Keyboard, Mouse, and Monitor

Connect the keyboard, mouse, and monitor (optional).

The connectors on the back of your system have icons indicating which cable to plug into each connector. Be sure to tighten the screws (if any) on the monitor's cable connector.

Connecting the Power Cable(s)

4

Connect the system’s power cable(s) to the system and, if a monitor is used, connect the monitor’s power cable to the monitor.

Getting Started With Your System

Securing the Power Cable(s)

Attach the power cable retention bracket on the right bend of the power supply handle. Bend the system power cable into a loop as shown in the illustration and attach to the bracket’s cable clasp.

Plug the other end of the power cable into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).

Turning On the System

Press the power button on the system and the monitor. The power indicators should light.

Getting Started With Your System

5

Installing the Optional Bezel

Install the bezel (optional).

Complete the Operating System Setup

If you purchased a preinstalled operating system, see the operating system documentation that ships with your system. To install an operating system for the first time, see the installation and configuration documentation for your operating system. Be sure the operating system is installed before installing hardware or software not purchased with the system.

Supported Operating Systems

• Microsoft

®

Windows Server

®

2008 R2 Standard, Enterprise, and Datacenter (x64) Editions

• Microsoft Windows Server 2008 Standard and Enterprise (x86) Editions with SP2

• Microsoft Windows Server 2008 Standard, Enterprise, and

Datacenter (x64) Editions with SP2

• Microsoft Windows Server 2008 Standard and Enterprise (x86) Editions

6

Getting Started With Your System

• Microsoft Windows Server 2008 Standard, Enterprise, and

Datacenter (x64) Editions (with Hyper-V role enabled)

• Microsoft Windows Server 2003 Standard and Enterprise (x86) Editions

• Microsoft Windows Server 2003 Standard and Enterprise (x64) Editions

• Microsoft Windows Server 2003 R2 Standard and Enterprise (x86)

Editions with SP2

• Microsoft Windows Server 2003 R2 Standard, Enterprise, and Datacenter (x64) Editions with SP2

• Microsoft Windows Essential Business Server 2008 Standard and

Premium (x64) Editions

• Microsoft Windows Server 2008 Hyper-V™

• Microsoft Windows Server 2008 R2 Hyper-V

• Microsoft Hyper-V Server 2008 R2

• SUSE

®

Linux Enterprise Server 11 (x86_64)

• SUSE Linux Enterprise Server 10 (x86_64) with SP3

• Solaris

®

10 10/9 (x86_64) (when available)

• VMware

®

ESX Version 4.0 Update 1

• VMware ESXi Version 4.0 Update 1

• Citrix

®

XenServer™ 5.6 (when available)

NOTE:

For the latest information on supported operating systems, see support.dell.com

.

Getting Started With Your System

7

Other Information You May Need

WARNING:

See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document.

• The rack documentation included with your rack solution describes how to install your system into a rack.

• The Hardware Owner’s Manual provides information about system features and describes how to troubleshoot the system and install or replace system components. This document is available online at support.dell.com/manuals .

• Any media that ships with your system that provides documentation and tools for configuring and managing your system, including those pertaining to the operating system, system management software, system updates, and system components that you purchased with your system.

NOTE:

Always check for updates on support.dell.com/manuals and read the updates first because they often supersede information in other documents.

Obtaining Technical Assistance

If you do not understand a procedure in this guide or if the system does not perform as expected, see your Hardware Owner’s Manual . Dell™ offers comprehensive hardware training and certification. See dell.com/training for more information. This service may not be offered in all locations.

8

Getting Started With Your System

Información de la NOM (sólo para México)

La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la Norma

Oficial Mexicana (NOM):

Importador:

Número de modelo:

Voltaje de alimentación:

Frecuencia:

Consumo eléctrico:

E05S

100–240 V CA

50/60 Hz

10–5 A

Technical Specifications

Processor

Processor type Up to four Intel

®

Xeon

®

7500 series processors

(up to eight core processors)

Or

Up to four Intel Xeon 6500 series processors

(up to eight core processors)

Getting Started With Your System

9

Expansion Bus

Bus type

Expansion slots

PCI Express Generation 2

Riser 1

Slot 1: x8 link with x16 physical connector,

9.5-inch length, standard height

Slot 2: x4 link with x8 physical connector, low-profile, with a standard height bracket

System Board

Slot 3: x8 link with x8 physical connector, low-profile

Slot 4: x8 link with x8 physical connector, low-profile

Riser 2

Slot 5: x8 link with x16 physical connector,

9.5-inch length, standard height

Slot 6: x8 link with x16 physical connector,

9.5-inch length, standard height

Memory

Architecture

Memory module sockets

Memory module capacities

Minimum RAM

Maximum RAM

1066 MHz DDR3 registered ECC DIMMs

Thirty two 240-pin

1 GB, 2 GB, 4 GB, 8 GB, or 16 GB RDIMMs

(single, dual, or quad-rank depending on capacity)

4 GB (per processor)

NOTE:

It is recommended that you install a minimum of 16 GB to run applications.

512 GB (with 16 GB RDIMMs)

10

Getting Started With Your System

Drives

Hard drives

Diskette drive

Optical drive

Flash drive

Up to six 2.5-inch, internal hot-swappable

SAS, SATA, or SSD drives

Optional external USB 1.44 MB

One optional slimline SATA DVD-ROM or DVD+RW drive

NOTE:

DVD devices are data only.

Optional internal USB

Optional internal dual SD module

Optional vFlash card (with iDRAC6

Enterprise card)

Connectors

Back

NIC

NIC (Management NIC)

Serial

USB

Video vFlash

Front

Video

USB

Internal

USB

SD

Four RJ-45 (for integrated 1 GB NICs)

One optional management NIC port on iDRAC6 Enterprise card

9-pin, DTE, 16550-compatible

Four 4-pin, USB 2.0-compliant

15-pin VGA

One optional vFlash memory card slot on iDRAC6 Enterprise card

15-pin VGA

Two 4-pin, USB 2.0-compliant

One 4-pin, USB 2.0-compliant

Two optional internal SD modules

Getting Started With Your System

11

Video

Video type

Video memory

Integrated Matrox G200 with iDRAC6

8 MB (shared with iDRAC application memory)

Power

AC power supply

Wattage (per power supply)

Voltage (per power supply)

System heat dissipation

Maximum inrush current

(per power supply)

1100 W

100–240 V, 50/60 Hz, auto-ranging

4012 BTU/Hr

Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for 10 ms or less

Batteries

System battery

RAID battery (optional)

Physical

Height

Width

Depth

Weight (maximum configuration)

Weight (empty)

CR 2032 3.0-V lithium coin cell

3.7 V lithium ion

8.642 cm (3.40 in)

44.05 cm (17.34 in) without bezel

48.24 cm (18.99 in) with bezel

72.06 cm (28.37 in) without bezel

75.56 cm (29.75 in) with bezel

26.1 kg (57.54 lb)

21.15 kg (46.64 lb)

12

Getting Started With Your System

Environmental

NOTE:

For additional information about environmental measurements for specific system configurations, see www.dell.com/environmental_datasheets .

Temperature

Operating 10° to 35°C (50° to 95°F) with a maximum temperature gradation of 10°C per hour

NOTE:

For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft.

Storage –40° to 65°C (–40° to 149°F) with a maximum temperature gradation of

20°C per hour

Relative humidity

Operating 20% to 80% (noncondensing) with a maximum humidity gradation of

10% per hour

5% to 95% (noncondensing) Storage

Maximum vibration

Operating

Storage

Maximum shock

Operating

0.26 G at 5–350 Hz for 15 min

0.5 G at 3–200 Hz for 15 min

Storage

One shock pulse in the positive z axis

(one pulse on each side of the system) of

31 G for 2.6 ms in the operational orientation

Six consecutively executed shock pulses in the positive and negative x, y, and z axes

(one pulse on each side of the system) of 71 G for up to 2 ms

Getting Started With Your System

13

Environmental

Altitude

Operating

Storage

Airborne Contaminant Level

Class

–16 to 3048 m (–50 to 10,000 ft)

NOTE:

For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft.

–16 to 10,600 m (–50 to 35,000 ft)

G2 or lower as defined by ISA-S71.04-1985

14

Getting Started With Your System

管制型号 E05S 系列

Dell™ PowerEdge™

R810

系统

系统使用入门

注、小心和警告

注: “注”表示可以帮助您更好地使用计算机的重要信息。

小心 : “小心”表示如果不遵循说明,就有可能损坏硬件或导致数据丢失。

警告 : “警告”表示可能会导致财产损失、人身伤害甚至死亡。

____________________

本说明文件中的信息如有更改,恕不另行通知。

© 2009 Dell Inc.

版权所有,翻印必究。

未经 Dell Inc. 书面许可,严禁以任何形式复制这些材料。

本文中使用的商标:

Dell

DELL

徽标和

PowerEdge

是 Dell Inc. 的商标;

Intel

Xeon

是 Intel Corporation 在美国和其他国家 / 地区的注册商标;

Microsoft

Windows

Windows Server

Hyper-V

是 Microsoft Corporation 在美国和 / 或其他国家 / 地区的商标或

注册商标;

SUSE

是 Novell, Inc. 在美国和其他国家 / 地区的注册商标;

Citrix

XenServer

是 Citrix Systems, Inc. 和 / 或其多个子公司的商标,并可能已在美国专利商标局和其他

国家 / 地区注册;

VMware

是 VMware, Inc. 在美国和 / 或其他辖区的注册商标或商标

(简称“商标”);

Solaris

是 Sun Microsystems, Inc. 在美国和其他国家 / 地区的商标。

本说明文件中述及的其它商标和产品名称是指拥有相应商标和产品名称的公司或其制

造的产品。 Dell Inc. 对其它公司的商标和产品名称不拥有任何所有权。

管制型号 E05S 系列

2009 年 11 月 P/N X917M Rev. A00

安装和配置

警告: 执行下列步骤之前,请查看系统随附的安全说明。

打开系统包装

打开系统包装并确认各个组件。

在机架中安装滑轨和系统

遵循系统随附的安全说明和机架安装说明,在机架中组装滑轨并安装系统。

系统使用入门 17

可选 – 连接键盘、鼠标和显示器

连接键盘、鼠标和显示器(可选)。

系统背面的连接器附有图标,指示要插入每个连接器的电缆。请确保拧紧显

示器电缆连接器上的螺钉(如果有)。

连接电源电缆

18

将系统电源电缆连接至系统,如果使用显示器,则将显示器电源电缆连接至

显示器。

系统使用入门

固定电源电缆

在电源设备手柄的右侧拐弯处上方连接电源电缆固定支架。如示意图所示,

将系统电源电缆弯曲成环状,并连接至支架的电缆挂钩。

将电源电缆的另一端插入接地的电源插座或单独的电源,如不间断电源设备

(UPS)

或配电装置

(PDU)

开启系统

按下系统和显示器的电源按钮。电源指示灯将会亮起。

系统使用入门 19

安装可选挡板

安装挡板(可选)。

完成操作系统安装

如果购买了预安装的操作系统,请参阅系统随附的操作系统说明文件。

第一次安装操作系统时,请参阅操作系统的安装和配置说明文件。

请确保先安装操作系统,然后再安装未预装的硬件或软件。

支持的操作系统

• Microsoft

®

Windows Server

®

2008 R2 (x64)

标准版、企业版

Datacenter

• Microsoft Windows Server 2008 (x86)

标准版和企业版(含

SP2

• Microsoft Windows Server 2008 (x64)

标准版、企业版和

Datacenter

(含

SP2

• Microsoft Windows Server 2008 (x86)

标准版和企业版

• 启用了

Hyper-V

角色的

Microsoft Windows Server 2008 (x64)

标准版、

企业版和

Datacenter

• Microsoft Windows Server 2003 (x86)

标准版和企业版

20 系统使用入门

• Microsoft Windows Server 2003 (x64)

标准版和企业版

• Microsoft Windows Server 2003 R2 (x86) 标准版和企业版(含 SP2 )

• Microsoft Windows Server 2003 R2 (x64)

标准版、

企业版和

Datacenter

版(含

SP2

• Microsoft Windows Small Business Server 2008 (x64) 标准版和高级版

• Microsoft Windows Server 2008 Hyper-V™

• Microsoft Windows Server 2008 R2 Hyper-V

• Microsoft Hyper-V Server 2008 R2

• SUSE

®

Linux Enterprise Server 11 (x86_64)

• SUSE Linux Enterprise Server 10 (x86_64) (含 SP3 )

• Solaris

®

10 10/9 (x86_64) (如果有)

• VMware

®

ESX 版本 4.0 更新 1

• VMware ESXi 4.0 版更新 1

• Citrix

®

XenServer™5.6

(如果有)

注: 有关支持的操作系统的最新信息,请访问 support.dell.com

可能需要的其他信息

警告: 请参阅系统随附的安全与管制信息。保修信息可能包括在该说

明文件中,也可能作为单独的说明文件提供。

机架解决方案附随的机架说明文件介绍了如何将系统安装到机架中。

《硬件用户手册》提供了有关系统功能的信息,并说明了如何排除

系统故障以及安装或更换系统组件。可在 support.dell.com/manuals

在线获取该说明文件。

系统随附的任何介质都提供了用于配置和管理系统的说明文件和

工具,包括随系统购买的操作系统、系统管理软件、系统更新以

及系统组件相关的说明文件和工具。

注: 请经常访问 support.dell.com/manuals

以获得更新,并首先

阅读这些更新,因为这些更新通常会取代其它说明文件中的信息。

系统使用入门 21

获得技术帮助

如果您对本指南中的步骤有疑问,或系统运行无法达到预期效果,请参阅

《硬件用户手册》。

Dell™

提供全面的硬件培训和认证。有关详情,请参阅 dell.com/training

。此服务可能并非在所有地区都提供。

技术规格

处理器

处理器类型 多达四个 Intel ® Xeon ® 7500 系列处理器

(多达八个核心处理器)

多达四个 Intel Xeon 6500 系列处理器

(多达八个核心处理器)

扩充总线

总线类型

扩充槽

PCI Express 第 2 代

提升板 1

插槽 1 : x8 链接(带 x16 物理连接器)、

9.5 英寸长、标准高度

插槽 2 : x4 链接(带 x8 物理连接器)、

矮型(带标准高度支架)

系统板

插槽 3 : x8 链接(带 x8 物理连接器)、

矮型

插槽 4 : x8 链接(带 x8 物理连接器)、

矮型

提升板 2

插槽 5 : x8 链接(带 x16 物理连接器)、

9.5 英寸长、标准高度

插槽 6 : x8 链接(带 x16 物理连接器)、

9.5 英寸长、标准高度

22 系统使用入门

内存

体系结构

内存模块插槽

内存模块容量

最小 RAM

最大 RAM

驱动器

硬盘驱动器

软盘驱动器

光盘驱动器

快擦写驱动器

连接器

背面

NIC

NIC (管理 NIC )

串行

USB

视频 vFlash

1066 MHz DDR3 已注册的 ECC DIMM

32 个 240 针

1 GB 、 2 GB 、 4 GB 、 8 GB 或 16 GB

RDIMM (根据容量,为单列、双列

或四列)

4 GB (每个处理器)

注: 建议安装的最小容量为 16 GB ,

以便运行应用程序。

512 GB (带 16 GB RDIMM )

多达六个 2.5 英寸内置热插拔 SAS 、 SATA 或

SSD 驱动器

可选的外部 USB 1.44 MB

一个可选的细长型 SATA DVD-ROM 或

DVD+RW 驱动器

注: DVD 设备仅用于数据。

可选的内部 USB

可选的内部双 SD 模块

可选的 vFlash 卡(带 iDRAC6 Enterprise 卡)

四个 RJ-45 (用于集成的 1 GB NIC )

一个可选的管理 NIC 端口,位于 iDRAC6 Enterprise 卡上

9 针、 DTE 、 16550 兼容连接器

四个 4 针、 USB 2.0 兼容连接器

15 针 VGA 连接器

一个可选的 vFlash 内存卡插槽,

位于 iDRAC6 Enterprise 卡上

系统使用入门 23

24

连接器 (续)

正面

视频

USB

内部

USB

SD

15 针

两个

VGA

4 针、

连接器

USB 2.0 兼容连接器

一个 4 针、 USB 2.0 兼容连接器

两个可选的内部 SD 模块

视频

视频类型 集成的 Matrox G200 (带 iDRAC6 )

视频内存 8

电源

交流电源设备

每个电源设备的功率

每个电源设备的电压

系统散热

1100 W

100 – 240 V 、 50/60 Hz 、自动量程

4012 BTU/Hr

每个电源设备的最大涌入电流 在典型的线路环境下和整个系统环境运行范

围内,每个电源设备在 10 毫秒或更短时间内

的涌入电流可达 55 A

电池

系统电池

RAID 电池(可选)

CR 2032 3.0V

3.7 V 锂电池

锂离子电池

物理规格

高度

宽度

厚度

重量(最大配置)

重量(空置)

8.642 厘米( 3.40 英寸)

44.05 厘米( 17.34 英寸)不带挡板

48.24 厘米( 18.99 英寸)带挡板

72.06 厘米( 28.37 英寸)不带挡板

75.56 厘米( 29.75 英寸)带挡板

26.1 千克( 57.54 磅)

21.15 千克( 46.64 磅)

系统使用入门

环境参数

注: 有关特定系统配置的环境测量值的其它信息,请参阅 www.dell.com/environmental_datasheets

温度

运行时

存储时

10 °至 35 ° C ( 50 °至 95 ° F ),最大温度变

化梯度为每小时 10 ° C

注: 海拔高度在 2950 英尺以上时,最高操作温

度按 1 ° F/550 英尺降低。

-40 ° 至 65 ° C ( -40 ° 至 149 ° F ),最大温度

变化梯度为每小时 20 ° C

相对湿度

运行时 20% 至 80% (非冷凝),最大湿度变化梯度为

每小时 10%

5% 至 95% (非冷凝) 存储时

最大振动

运行时

存储时

最大撞击

运行时

在 5 – 350 Hz 、 0.26 G 时,可持续 15 分钟

在 3 – 200 Hz 、 0.5 G 时,可持续 15 分钟

存储时 z 轴正方向上可承受一个 31 G 的撞击脉冲

(系统每一面承受一个脉冲),在操作方向

最多可持续 2.6 毫秒 x 、 y 和 z 轴正负方向上可承受连续六个 71 G 的

撞击脉冲(系统每一面承受一个脉冲),最长可

持续 2 毫秒

海拔高度

运行时 -16 至 3,048 米( -50 至 10,000 英尺)

注: 海拔高度在 2950 英尺以上时,最高操作

温度按 1 ° F/550 英尺降低。

-16 至 10,600 米( -50 至 35,000 英尺) 存储时

气载污染物级别

分类 G2 或更低(根据 ISA-S71.04-1985 定义的标准)

系统使用入门 25

26 系统使用入门

Model Regulasi Seri E05S

Sistem Dell™

PowerEdge™ R810

Memulai Dengan

Sistem Anda

Catatan, Perhatian, dan Peringatan

CATATAN:

CATATAN menunjukkan informasi penting yang membantu Anda untuk menggunakan komputer dengan lebih baik.

PERHATIAN:

PERHATIAN menunjukkan kemungkinan kerusakan pada perangkat keras atau hilangnya data jika petunjuk tidak diikuti.

PERINGATAN:

PERINGATAN menunjukkan kemungkinan kerusakan barang, cedera tubuh, atau kematian.

____________________

Informasi dalam dokumen ini dapat berubah tanpa pemberitahuan.

© 2009 Dell Inc. Hak cipta dilindungi undang-undang.

Dilarang keras memperbanyak materi ini dengan cara apa pun tanpa izin tertulis dari Dell Inc.

Merek dagang yang digunakan dalam dokumen ini: Dell , logo DELL dan PowerEdge adalah merek dagang dari Dell Inc.; Intel dan Xeon adalah merek dagang terdaftar dari Intel Corporation di A.S dan negara-negara lainnya; Microsoft , Windows , Windows Server dan Hyper-V adalah merek dagang atau merek dagang terdaftar dari Microsoft Corporation di Amerika Serikat dan/atau negera-negara lainnya; SUSE adalah merek dagang terdaftar dari Novell, Inc., di Amerika Serikat dan negara-negara lainnya; Citrix dan XenServer adalah merek dagang dari Citrix Systems, Inc. dan/atau beberapa anak perusahaannya, dan mungkin terdaftar pada Kantor Paten dan Merek Dagang Amerika Serikat dan di negara-negara lainnya; VMware adalah merek dagang terdaftar atau merek dagang (“Merek”) dari VMware, Inc. di Amerika Serikat dan/atau di wilayah-wilayah hukum lainnya; Solaris adalah merek dagang dari Sun Microsystems, Inc. di Amerika Serikat dan negara-negara lainnya.

Merek dagang dan nama dagang lain mungkin digunakan dalam dokumen ini untuk merujuk ke pihak lain yang memiliki hak kekayaan intelektual atas merek dan nama produk mereka. Dell Inc. menyangkal adanya kepentingan kepemilikan apa pun atas merek dagang dan nama dagang selain miliknya sendiri.

Model Regulasi Seri E05S

November 2009 No. Komp. X917M Rev. A00

Instalasi dan Konfigurasi

PERINGATAN:

Sebelum melakukan prosedur berikut, bacalah petunjuk keselamatan yang disertakan dengan sistem.

Membuka kemasan Sistem

Buka kemasan sistem Anda dan kenali masing-masing barang.

Memasang Rel dan Sistem dalam Rak

Rakit rel dan pasang sistem dalam rak dengan mengikuti petunjuk keselamatan dan petunjuk pemasangan rak yang disertakan dengan sistem Anda.

Memulai Dengan Sistem Anda

29

Opsional – Menghubungkan Keyboard, Mouse, dan Monitor

Hubungkan keyboard, mouse, dan monitor (opsional).

Konektor di bagian belakang sistem Anda ditandai dengan ikon yang menunjukkan kabel mana yang harus ditancapkan ke masing-masing konektor. Pastikan untuk mengencangkan sekrup (jika ada) pada konektor kabel monitor.

Menghubungkan Kabel Daya

30

Hubungkan kabel daya sistem ke sistem dan, jika monitor digunakan, hubungkan kabel daya monitor ke monitor.

Memulai Dengan Sistem Anda

Mengamankan Kabel Daya

Sangkutkan braket penahan kabel daya di arah lekukan kanan gagang catu daya. Tekuk kabel daya sistem secara melingkar seperti ditunjukkan pada gambar kemudian kencangkan kabel dengan pengikat kabel braket.

Tancapkan ujung kabel daya yang lain ke stopkontak listrik yang ditanahkan atau sumber daya terpisah seperti catu daya tak terputus (UPS) atau unit distribusi daya (PDU).

Menyalakan Sistem

Tekan tombol daya pada sistem dan monitor. Indikator daya seharusnya menyala.

Memulai Dengan Sistem Anda

31

Memasang Bezel Opsional

Pasang bezel (opsional).

Menyelesaikan Pemasangan Sistem Operasi

Jika Anda membeli sistem operasi yang telah terinstal, lihat dokumentasi sistem operasi yang dikirimkan dengan sistem Anda. Untuk menginstal sistem operasi untuk pertama kalinya, lihat dokumentasi instalasi dan konfigurasi untuk sistem operasi Anda. Pastikan bahwa sistem operasi telah terinstal sebelum Anda menginstal perangkat keras atau perangkat lunak yang tidak dibeli bersama sistem.

32

Memulai Dengan Sistem Anda

Sistem Operasi yang Didukung

• Microsoft

®

Windows Server

®

2008 R2 edisi Standard, Enterprise, dan Datacenter (x64)

• Microsoft Windows Server 2008 edisi Standard dan Enterprise (x86) dengan SP2

• Microsoft Windows Server 2008 edisi Standard, Enterprise, dan Datacenter (x64) dengan SP2

• Microsoft Windows Server 2008 edisi Standard dan Enterprise (x86)

• Microsoft Windows Server 2008 edisi Standard, Enterprise, dan Datacenter (x64) (dengan fungsi Hyper-V diaktifkan)

• Microsoft Windows Server 2003 edisi Standard dan Enterprise (x86)

• Microsoft Windows Server 2003 edisi Standard dan Enterprise (x64)

• Microsoft Windows Server 2003 R2 edisi Standard, dan Enterprise (x86) dengan SP2

• Microsoft Windows Server 2003 R2 edisi Standard, Enterprise, dan Datacenter (x64) dengan SP2

• Microsoft Windows Essential Business Server 2008 edisi Standard dan Premium (x64)

• Microsoft Windows Server 2008 Hyper-V™

• Microsoft Windows Server 2008 R2 Hyper-V

• Microsoft Hyper-V Server 2008 R2

• SUSE

®

Linux Enterprise Server 11 (x86_64)

• SUSE Linux Enterprise Server 10 (x86_64) dengan SP3

• Solaris

®

10 10/9 (x86_64) (jika tersedia)

• VMware

®

ESX Versi 4.0 Pembaruan 1

• VMware ESXi Versi 4.0 Pembaruan 1

• Citrix

®

XenServer™ 5.6 (jika tersedia)

CATATAN:

Untuk informasi terkini mengenai sistem operasi yang didukung, lihat support.dell.com

.

Memulai Dengan Sistem Anda

33

Informasi Lain Yang Mungkin Anda Perlukan

PERINGATAN:

Lihat informasi keselamatan dan peraturan yang dikirimkan dengan sistem Anda. Informasi garansi mungkin disertakan dalam dokumen ini atau sebagai dokumen yang terpisah.

• Dokumentasi rak juga mencakup solusi rak yang menggambarkan cara memasang sistem Anda dalam rak.

• Panduan Pemilik Perangkat Keras berisi informasi tentang fitur sistem dan menjelaskan cara mengatasi masalah sistem dan menginstal atau mengganti komponen sistem. Dokumen ini tersedia secara online di support.dell.com/manuals .

• Semua media yang dikirimkan dengan sistem yang berisi dokumentasi dan alat untuk mengonfigurasikan dan mengelola sistem Anda, termasuk yang berhubungan dengan sistem operasi, perangkat lunak manajemen sistem, pembaruan sistem, dan komponen sistem yang dibeli bersama dengan sistem Anda.

CATATAN:

Selalu periksa pembaruan di support.dell.com/manuals dan bacalah pembaruan tersebut terlebih dahulu karena seringkali menggantikan informasi dalam dokumen lain.

Mendapatkan Bantuan Teknis

Jika Anda tidak memahami suatu prosedur dalam panduan ini atau jika sistem tidak bekerja seperti yang diharapkan, lihat Panduan Pemilik Perangkat

Keras . Dell™ menyediakan pelatihan dan sertifikasi perangkat keras yang komprehensif. Lihat dell.com/training untuk informasi selebihnya.

Layanan ini mungkin tidak tersedia di semua lokasi.

34

Memulai Dengan Sistem Anda

Spesifikasi Teknis

Prosesor

Tipe prosesor Hingga empat prosesor Intel

®

Xeon

® seri 7500 (hingga prosesor delapan inti)

Atau

Hingga empat prosesor Intel Xeon seri 6500

(hingga prosesor delapan inti)

Bus Ekspansi

Tipe bus

Slot ekspansi

PCI Express Generasi 2

Riser 1

Slot 1: Tautan x8 dengan konektor fisik x16, panjang 9,5-inci, tinggi standar

Slot 2: Tautan x4 dengan konektor fisik x8, profil rendah, dengan tinggi braket standar

Papan Sistem

Slot 3: Tautan x8 dengan konektor fisik x8, profil rendah

Slot 4: Tautan x8 dengan konektor fisik x8, profil rendah

Riser 2

Slot 5: Tautan x8 dengan konektor fisik x16, panjang 9,5-inci, tinggi standar

Slot 6: Tautan x8 dengan konektor fisik x16, panjang 9,5-inci, tinggi standar

Memulai Dengan Sistem Anda

35

Memori

Arsitektur

Soket modul memori

Kapasitas modul memori

RAM minimum

RAM maksimum

Drive

Hard drive

Drive disket

Drive optik

Flash drive

DIMM ECC terdaftar DDR3 1066 MHz

Tigapuluh dua 240 pin

RDIMM 1 GB, 2 GB, 4 GB, 8 GB, atau 16 GB

(single, dual, atau quad-rank tergantung kapasitas)

4 GB (per prosesor)

CATATAN:

Kami rekomendasikan untuk menginstal minumum 16GB untuk menjalankan aplikasi.

512 GB (dengan RDIMM 16 GB)

Hingga enam drive internal SAS, SATA atau SSD hot-swappable 2,5-inci

USD eksternal 1,44 MB opsional

Satu drive DVD-ROM atau DVD+RW SATA slimline opsional

CATATAN:

Perangkat DVD hanya data.

USB internal opsional

Modul dual SD internal opsional

Kartu vFlash opsional (dengan kartu

Enterprise iDRAC6)

36

Memulai Dengan Sistem Anda

Konektor

Belakang

NIC

NIC (NIC Manajemen)

Serial

USB

Video vFlash

Depan

Video

USB

Internal

USB

SD

Video

Tipe video

Memori video

Emapt RJ-45 (untuk NIC 1GB terpadu)

Satu port NIC manajemen opsional pada kartu

Enterprise iDRAC6

9-pin, DTE, kompatibel dengan 16550

Empat 4-pin, memenuhi standar USB 2.0

VGA 15-pin

Satu slot kartu memori vFlash opsional pada kartu Enterprise iDRAC6

VGA 15-pin

Dua 4-pin, memenuhi standar USB 2.0

Satu 4-pin, memenuhi standar USB 2.0

Dua modul SD internal opsional

Matrix G200 terpadu dengan iDRAC6

8 MB (berbagi dengan memori aplikasi iDRAC)

Memulai Dengan Sistem Anda

37

Daya

Catu daya AC

Daya watt (per catu daya)

Tegangan (per catu daya)

Pelepasan panas sistem

Maksimum lonjakan arus

(per catu daya)

Baterai

Baterai sistem

Baterai RAID (opsional)

Fisik

Tinggi

Lebar

Tebal

Berat (konfigurasi maksimum)

Berat (kosong)

1100 W

100–240 V, 50/60 Hz, kisaran otomatis

4012 BTU/jam

Pada kondisi jaringan listik tipikal dan di seluruh kisaran pengoperasian normal sistem, lonjakan arus dapat mencapai 55 A per catu daya selama 10 mdtk atau kurang

Sel koin lithium CR 2032 3,0 V

Ion lithium 3,7 V

8,642 cm (3,40 inci)

44,05 cm (17,34 inci) tanpa bezel

48,24 cm (18,99 inci) dengan bezel

72,06 cm (28,37 inci) tanpa bezel

75,56 cm (29,75 in) dengan bezel

26,1 kg (57,54 pon)

21,15 kg (46,64 pon)

38

Memulai Dengan Sistem Anda

Lingkungan

CATATAN:

Untuk informasi lebih lanjut mengenai ukuran lingkungan untuk konfigurasi sistem spesifik, lihat www.dell.com/environmental_datasheets .

Suhu

Pengoperasian 10° sampai dengan 35°C (50° sampai dengan 95°F) dengan perubahan suhu maksimum 10°C per jam

CATATAN:

Pada ketinggian di atas 900 m

(2.950 ft), suhu pengoperasian maksimum berkurang 1°C/300 m (1°F/550 ft).

Penyimpanan –40° sampai dengan 65°C (–40° sampai dengan 149°F) dengan perubahan suhu maksimum 20°C per jam

Kelembapan relatif

Pengoperasian

Penyimpanan

20% sampai dengan 80%

(tanpa pengembunan) dengan perubahan kelembapan 10% per jam

5% sampai dengan 95%

(tanpa pengembunan)

Getaran maksimum

Pengoperasian

Penyimpanan

Guncangan maksimum

Pengoperasian

0,26 G pada 5–350 Hz selama 15 men

0,5 G pada 3–200 Hz selama 15 men

Penyimpanan

Satu pulsa guncangan pada sumbu z positif

(satu pulsa pada setiap sisi sistem) sebesar

31 G selama 2,6 mdtk dalam orientasi pengoperasian

Enam pulsa guncangan yang terjadi berurutan pada sumbu x, y, dan z positif dan negatif (satu pulsa pada setiap sisi sistem) sebesar 71 G hingga 2 mdtk

Memulai Dengan Sistem Anda

39

Lingkungan

(Bersambung)

Ketinggian

Pengoperasian

Penyimpanan

Tingkat Pencemaran Udara

Kelas

–16 sampai dengan 3.048 m

(–50 sampai dengan 10.000 ft)

CATATAN:

Pada ketinggian di atas 900 m

(2.950 ft), suhu pengoperasian maksimum berkurang 1°C/300 m (1°F/550 ft).

–16 sampai dengan 10.600 m

(–50 sampai dengan 35.000 ft)

G2 atau yang lebih rendah sesuai standar ISA-S71.04-1985

40

Memulai Dengan Sistem Anda

認可モデル E05S シリーズ

Dell™ PowerEdge™

R810

システム

はじめに

メモ、注意、警告

メモ: コンピュータを使いやすくするための重要な情報を説明しています。

注意: 手順に従わない場合は、ハードウェアの損傷やデータの損失の可能

性があることを示しています。

警告: 物的損害、けが、または死亡の原因となる可能性があることを示

しています。

____________________

本書の内容は予告なく変更されることがあります。

© 2009 すべての著作権は Dell Inc. にあります。

Dell Inc. の書面による許可のない複製は、いかなる形態においても厳重に禁じられています。

本書に使用されている商標: Dell 、 DELL ロゴ、および PowerEdge は Dell Inc.

の商標

です。

Intel

および

Xeon

は米国その他の国における

Intel Corporation

の登録商標です。

Microsoft 、 Windows 、 Windows Server および Hyper-V は米国その他の国における

Microsoft Corporation

の商標または登録商標です。

SUSE

は米国その他の国における

Novell, Inc. の登録商標です。 Citrix および XenServer は Citrix Systems, Inc. および / また

はその関連子会社の商標であり、米国特許商標局および他の国で登録されている場合が

あります。 VMware は米国その他の法域における VMware, Inc. の登録商標または商標

(標章)です。

Solaris

は米国その他の国における

Sun Microsystems, Inc.

の商標です。

商標または製品の権利を主張する事業体を表すためにその他の商標および社名が使用さ

れていることがあります。それらの商標や会社名は、一切 Dell Inc. に帰属するものでは

ありません。

認可モデル E05S シリーズ

2009 年 11 月 P/N X917M Rev. A00

取り付けと設定

警告: 次の手順を実行する前に、システムに付属しているマニュアルの

安全にお使いいただくための注意事項をお読みください。

システムの開梱

システムを箱から取り出し、同梱品がすべて揃っていることを確認

します。

ラックへのレールとシステムの取り付け

レールの組み立てとラックへのシステムの取り付けの際は、システムに

付属しているマニュアルの、安全にお使いいただくための注意事項およ

びラックへの取り付け手順に従ってください。

はじめに 43

オプション – キーボード、マウス、モニターの接続

キーボード、マウス、モニター(オプション)を接続します。

システム背面のコネクタには、どのケーブルを各コネクタに接続す

るかを示すアイコンがあります。モニターのケーブルコネクタにネ

ジがある場合は、必ず締めてください。

電源ケーブルの接続

44

システムの電源ケーブルをシステムに接続し、モニターを使用する場

合は、モニターの電源ケーブルをモニターに接続します。

はじめに

電源ケーブルの固定

電源ケーブル固定ブラケットを電源ユニットハンドルの右ベンドに取

り付けます。システムの電源ケーブルをループ状に曲げ(図を参照)、

ブラケットのケーブル留め金に取り付けます。

電源ケーブルのもう一方の端をアースされた電源コンセントまたは UPS

(無停電電源装置)や配電装置( PDU )などの電源に接続します。

システムの電源投入

システムとモニターの電源ボタンを押します。電源インジケータが点灯

します。

はじめに 45

ベゼル(オプション)の取り付け

46

ベゼル(オプション)を取り付けます。

OS

のセットアップの完了

システムに OS がプリインストールされている場合は、システムに同梱

の OS のマニュアルを参照してください。 OS を初めてインストールす

る場合は、お使いの OS のインストールと設定に関するマニュアルを参

照してください。システムとは別途に購入したハードウェアやソフト

ウェアのインストールは、 OS がインストール済みであることを確認し

てから行ってください。

対応

OS

• Microsoft

®

Windows Server

®

Datacenter ( x64 ) Edition

2008 R2 Standard/Enterprise/

• Microsoft Windows Server 2008 Standard/Enterprise ( x86 )

Edition With SP2

• Microsoft Windows Server 2008 Standard/Enterprise/

Datacenter ( x64 ) Edition With SP2

• Microsoft Windows Server 2008 Standard/

Enterprise ( x86 ) Edition

はじめに

• Microsoft Windows Server 2008 Standard/Enterprise/

Datacenter ( x64 ) Edition ( Hyper-V の役割を有効に設定)

• Microsoft Windows Server 2003 Standard/

Enterprise ( x86 ) Edition

• Microsoft Windows Server 2003 Standard/

Enterprise ( x64 ) Edition

• Microsoft Windows Server 2003 R2 Standard/

Enterprise ( x86 ) Editions With SP2

• Microsoft Windows Server 2003 R2 Standard/Enterprise/

Datacenter ( x64 ) Edition With SP2

• Microsoft Windows Essential Business Server 2008

Standard/Premium ( x64 ) Edition

• Microsoft Windows Server 2008 Hyper-V™

• Microsoft Windows Server 2008 R2 Hyper-V

• Microsoft Hyper-V Server 2008 R2

• SUSE

®

Linux Enterprise Server 11 ( x86_64 )

• SUSE Linux Enterprise Server 10 ( x86_64 ) With SP3

• Solaris

®

10 10/9 ( x86_64 )(利用可能時)

• VMware

®

ESX Version 4.0 アップデート 1

• VMware ESXi バージョン 4.0 アップデート 1

• Citrix

®

XenServer™ 5.6

(利用可能時)

メモ: 対応 OS の最新情報については、 support.dell.com

を参照してください。

はじめに 47

その他の情報

警告: システムに付属のマニュアルで安全および認可機関に関する情

報を参照してください。保証情報は、このマニュアルに含まれている

場合と、別の文書として付属する場合があります。

• ラックソリューションに付属のマニュアルでは、システムを

ラックに取り付ける方法について説明しています。

• 『ハードウェアオーナーズマニュアル』では、システムの機能、

トラブルシューティングの方法、およびコンポーネントの取

この文書は support.dell.com/manuals からオンラインで入手できます。

• システムに付属のメディアには、 OS 、システム管理ソフトウェア、

システムアップデート、およびシステムと同時に購入したシステム

コンポーネントに関するものを含め、システムの設定と管理用のマ

ニュアルとツールが収録されています。

メモ: アップデートには他の文書の内容を差し替える情報が含まれ

ている場合がよくありますので、 support.dell.com/manuals でアップ

デートがないかどうかを常に確認し、初めにお読みください。

テクニカルサポートの利用法

本書の手順が理解できない場合やシステムが思ったとおりに動作しな

い場合は、

デルでは広範囲にわたるハードウェアのトレーニングと資格認証を実

施しています。詳細については、 dell.com/training を参照してくだ

さい。このサービスが提供されていない地域もあります。

48 はじめに

仕様

プロセッサ

プロセッサのタイプ

拡張バス

バスのタイプ

拡張スロット

Intel

®

Xeon

®

7500 シリーズのプロセッ

サが 4 個まで( 8 コアまで)

または

Intel Xeon 6500 シリーズのプロセッ

サが 4 個まで( 8 コアまで)

PCI Express Gen 2

ライザー 1

スロット 1: x8 リンクで x16 の物理コネクタ、

9.5 インチ長、標準ハイト

スロット 2: x4 リンクで x8 の物理コネクタ、

ロープロファイル、標準ハイトのブラケット

付き

システム基板

スロット 3: x8 リンクで x8 の物理コネクタ、

ロープロファイル

スロット 4: x8 リンクで x8 の物理コネクタ、

ロープロファイル

ライザー 2

スロット 5: x8 リンクで x16 の物理コネクタ、

9.5 インチ長、標準ハイト

スロット 6: x8 リンクで x16 の物理コネクタ、

9.5 インチ長、標準ハイト

はじめに 49

メモリ

アーキテクチャ

メモリモジュールソケット

メモリモジュールの容量

最小 RAM

1066 MHz DDR3 レジスタ ECC DIMM

240 ピンソケット 32 個

1 GB 、 2 GB 、 4 GB 、 8 GB 、または 16 GB の

GB RDIMM (容量に応じて、シングル、デュ

アル、またはクアッドランク)

4 GB (各プロセッサに)

メモ: アプリケーションを実行するには、

少なくとも 16 GB の RAM を取り付けること

をお勧めします。

512 GB ( 16 GB の RDIMM を使用) 最大 RAM

ドライブ

ハードドライブ

ディスケットドライブ

オプティカルドライブ

フラッシュドライブ

ホットスワップ対応の 2.5 インチ SAS 、

SATA 、または SSD 内蔵ドライブ 6 台まで

オプションの外付け USB 1.44 MB

オプションのスリムライン SATA DVD-ROM

または DVD+RW ドライブ 1 台

メモ: DVD デバイスはデータ専用。

オプションの内蔵 USB ドライブ

オプションの内蔵デュアル SD モジュール

オプションの vFlash カード

( iDRAC6 Enterprise カード使用)

50 はじめに

コネクタ

背面

NIC

NIC

USB

(管理

シリアル

ビデオ vFlash

NIC )

RJ-45 (内蔵 1 GB NIC 用) 個 iDRAC6 Enterprise カード上にオプションの管理

NIC ポート 1 個

16550 互換 9 ピン DTE

4 ピン USB 2.0 対応コネクタ 4 個

15 ピン VGA iDRAC6 Enterprise カード上にオプションの vFlash メモリカードスロット 1 個

前面

ビデオ

USB

内蔵

USB

SD

15

4

ピン

ピン

VGA

USB 2.0 対応コネクタ 2 個

4 ピン USB 2.0 対応コネクタ 1 個

オプションの内蔵 SD モジュール 2 個

ビデオ

ビデオのタイプ 内蔵 Matrox G200 ( iDRAC6 使用)

ビデオメモリ 8

電源

AC 電源ユニット

ワット数

(電源ユニット 1 台当たり)

1100 W

電圧

(電源ユニット 1 台当たり)

システム熱消費

100 ~ 240 V 、 50/60 Hz 、オートレンジ

4012 BTU / 時

最大流入電流

(電源ユニット 1 台当たり)

通常のラインコンディションのもと、システム

の動作環境全範囲で、電源ユニット 1 台に付き

10 ミリ秒以下で 55 A の入電量を許容できます

はじめに 51

電源 (続き)

バッテリー

システムバッテリー

RAID バッテリー

(オプション)

サイズと重量

縦幅

横幅

奥行き

重量(最大構成)

重量(空の状態)

3.0 V コイン型リチウムバッテリー CR 2032

3.7 V リチウムイオン

8.642 cm

44.05 cm (ベゼルを含まず)

48.24 cm (ベゼルを含む)

72.06 cm (ベゼルを含まず)

75.56 cm (ベゼルを含む)

26.1 kg

21.15 kg

環境

メモ: 特定のシステム構成でのその他の環境条件の詳細については、 www.dell.com/environmental_datasheets を参照してください。

温度

動作時

保管時

1 時間当たり最大 10 ° C の温度変化で

10 ~ 35 ° C

メモ: 高度が 900 m を超えると、動作時の許

容最大温度は、 300 m ごとに 1 ° C ずつ低下し

ます。

1 時間当たり最大 20 ° C の温度変化で

-40 ~ 65 ° C

相対湿度

動作時

保管時

1 時間当たり最大 10 パーセントの湿度変

化で 20 ~ 80 パーセント(結露しないこと)

5 ~ 95 パーセント(結露しないこと)

52 はじめに

環境 (続き)

最大耐久震度

動作時

保管時

最大耐久衝撃

動作時

保管時

高度

動作時

保管時

空気汚染物質レベル

クラス

15 分間にわたり 5-350 Hz で 0.26 G

15 分間にわたり 3-200 Hz で 0.5 G z 軸の正方向に 2.6 ミリ秒で 31 G の 1 衝撃パ

ルス(システムの各面に対して 1 パルス) x 、 y 、 z 軸の正および負方向に 6 連続衝撃パルス

(システムの各面に対して 1 パルス)、 2 ミリ秒

以下で 71 G

-16 ~ 3,048 m

メモ: 高度が 900 m を超えると、動作時の許

容最大温度は、 300 m ごとに 1 ° C ずつ低下し

ます。

-16 ~ 10,600 m

G2 またはそれ未満

( ISA-S71.04-1985 の定義による)

はじめに 53

54 はじめに

규정 모델 E05S 시리즈

Dell™ PowerEdge™

R810

시스템

시스템시작하기

주 , 주의 및 경고

주 : 주는 컴퓨터를 보다 효율적으로 사용하는 데 도움을 주는 중요 정보를 제

공합니다 .

주의 : 주의는 지침을 준수하지 않을 경우의 하드웨어 손상이나 데이터 손실

위험을 설명합니다 .

경고 : 경고는 재산상의 피해나 심각한 부상 또는 사망을 유발할 수 있는 위

험이 있음을 알려줍니다 .

____________________

이 문서의 정보는 사전 통보 없이 변경될 수 있습니다 .

© 2009 Dell Inc.

저작권 본사 소유 .

Dell Inc.

의 서면 승인 없이 어떠한 방식으로든 본 자료를 무단 복제하는 행위는 엄격히

금지됩니다 .

본 설명서에 사용된 상표인

Dell

,

DELL

로고 및

PowerEdge

는 Dell Inc.

의 상표이며

Intel

Xeon 은 미국 및 기타 국가에서 Intel Corporation 의 등록 상표입니다 . Microsoft , Windows ,

Windows Server

Hyper-V

는 미국 및 / 또는 기타 국가에서 Microsoft Corporation 의 상표

또는 등록 상표입니다 .

SUSE 는 미국 및 기타 국가에서 Novell, Inc.

의 등록 상표입니다 .

Citrix

XenServer

는 Citrix Systems, Inc. 및 / 또는 해당 자회사의 상표이며 미국 특허청

및 기타 국가의 특허 기관에 등록되어 있을 수 있습니다 . VMware 는 미국 및 / 또는 기타

관할 지역에서 VMware, Inc.

의 등록 상표 또는 상표 ( 이하 " 상표 " 로 통칭 ) 입니다 .

Solaris 는 미국 및 기타 국가에서 Sun Microsystems, Inc.

의 상표입니다 .

본 문서에서 특정 회사의 표시나 제품 이름을 지칭하기 위해 기타 상표나 상호를 사용할

수도 있습니다 . Dell Inc.

는 자사가 소유하고 있는 것 이외에 기타 모든 상표 및 상호에

대한 어떠한 소유권도 없습니다 .

규정 모델 E05S 시리즈

2009 년 11 월 P/N X917M Rev. A00

설치 및 구성

경고 : 다음 절차를 수행하기 전에 시스템과 함께 제공되는 안전 지침을 검토

하십시오 .

시스템 포장 풀기

시스템 포장을 풀고 각 항목을 확인합니다 .

레일 및 시스템을 랙에 설치

시스템과 함께 제공되는 안전 지침 및 랙 설치 지침에 따라 레일을 조립하

고 시스템을 랙에 설치합니다 .

시스템시작하기 57

선택 사양 – 키보드 , 마우스 및 모니터 연결

키보드 , 마우스 및 모니터 ( 선택 사양 ) 를 연결합니다 .

시스템 후면에 있는 커넥터에는 각 커넥터에 연결될 케이블이 표시된

아이콘이 있습니다 . 모니터의 케이블 커넥터에 있는 나사 ( 해당하는

경우 ) 를 단단히 고정하십시오 .

전원 케이블 연결

58

시스템의 전원 케이블을 시스템에 연결하고 , 모니터를 사용하는 경우

모니터의 전원 케이블을 모니터에 연결합니다 .

시스템시작하기

전원 케이블 고정

전원 공급 장치 핸들의 오른쪽 벤드에 전원 케이블 고정 브래킷을 연결합

니다 . 그림과 같이 시스템 전원 케이블을 고리 안으로 구부려서 브래킷의

케이블 걸쇠에 연결합니다 .

전원 케이블의 반대쪽 끝을 접지된 전원 콘센트나 , UPS( 무정전 전원

공급 장치 ) 또는 PDU( 배전 장치 ) 와 같은 별도의 전원에 연결합니다 .

시스템 켜기

시스템과 모니터의 전원 단추를 누릅니다 . 전원 표시등이 켜집니다 .

시스템시작하기 59

베젤 ( 선택 사양 ) 설치

베젤 ( 선택 사양 ) 을 설치합니다 .

운영 체제 설치 완료

시스템 구입 시 운영 체제가 미리 설치되어 있는 경우 시스템과 함께 제

공되는 운영 체제 설명서를 참조하십시오 . 운영 체제를 처음 설치하려면

운영 체제 설치 및 구성 설명서를 참조하십시오 . 시스템과 함께 구입하지

않은 하드웨어 또는 소프트웨어를 설치하기 전에 운영 체제가 설치되어

있는지 확인하십시오 .

60 시스템시작하기

지원되는 운영 체제

• Microsoft

®

Windows Server

®

2008 R2 Standard, Enterprise

Datacenter(x64) Edition

• Microsoft Windows Server 2008 Standard

Enterprise(x86) Edition SP2

• Microsoft Windows Server 2008 Standard, Enterprise 및 Datacenter(x64)

Edition SP2

• Microsoft Windows Server 2008 Standard 및 Enterprise(x86) Edition

• Microsoft Windows Server 2008 Standard, Enterprise 및 Datacenter(x64)

Edition(

활성화된

Hyper-V

역할 포함

)

• Microsoft Windows Server 2003 Standard 및 Enterprise(x86) Edition

• Microsoft Windows Server 2003 Standard

Enterprise(x64) Edition

• Microsoft Windows Server 2003 R2 Standard 및 Enterprise(x86)

Edition SP2

• Microsoft Windows Server 2003 R2 Standard, Enterprise 및

Datacenter(x64) Edition SP2

• Microsoft Windows Essential Business Server 2008 Standard 및

Premium(x64) Edition

• Microsoft Windows Server 2008 Hyper-V ™

• Microsoft Windows Server 2008 R2 Hyper-V

• Microsoft Hyper-V Server 2008 R2

• SUSE

®

Linux Enterprise Server 11(x86_64)

• SUSE Linux Enterprise Server 10(x86_64) SP3

• Solaris

®

10 10/9(x86_64)( 가능한 경우 )

• VMware

®

ESX 버전 4.0 업데이트 1

• VMware ESXi 버전 4.0 업데이트 1

• Citrix

®

XenServer ™ 5.6( 가능한 경우 )

주 : 지원되는 운영 체제에 대한 최신 정보는 support.dell.com

을 참조하십시오 .

시스템시작하기 61

기타 필요한 정보

경고 : 시스템과 함께 제공된 안전 및 규제 정보를 참조하십시오 . 보증 정보

는 본 문서에 포함되거나 별도의 문서로 제공될 수 있습니다 .

• 랙 솔루션과 함께 제공되는 랙 설명서에는 시스템을 랙에 설치하는 방

법이 기술되어 있습니다 .

• 하드웨어 소유자 매뉴얼 에서는 시스템 기능에 대한 정보를 제공하고

시스템 문제 해결 방법 및 시스템 구성요소 설치 또는 교체 방법을 설명

합니다 . 이 문서는 support.dell.com/manuals 에서 온라인으로도 제공됩

니다 .

• 운영 체제 , 시스템 관리 소프트웨어 , 시스템 업데이트 및 시스템과 함께

구입한 시스템 구성요소와 관련된 설명서 및 도구를 비롯하여 시스템

을 구성 및 관리하는 데 필요한 설명서 및 도구를 제공하는 모든 매체가

시스템과 함께 제공됩니다 .

주 : 새로운 업데이트가 없는지 support.dell.com/manuals 에서 항상 확인

하십시오 . 업데이트에는 최신 정보가 수록되어 있으므로 다른 문서를 읽

기 전에 반드시 먼저 참조하시기 바랍니다 .

기술 지원 얻기

본 안내서의 절차가 잘 이해되지 않거나 시스템이 제대로 작동하지 않

을 경우 하드웨어 소유자 매뉴얼 을 참조하십시오 . Dell ™은 포괄적인 하

드웨어 교육 및 인증을 제공합니다 . 자세한 내용은 dell.com/training

을 참

조하십시오 . 지역에 따라 이 서비스가 제공되지 않을 수도 있습니다 .

62 시스템시작하기

기술 사양

프로세서

프로세서 유형

확장 버스

버스 유형

확장 슬롯

최대 4 개의 Intel ® Xeon ® 7500 시리즈 프로

세서 ( 최대 8 코어 프로세서 )

또는

최대 4 개의 Intel Xeon 6500 시리즈 프로세

서 ( 최대 8 코어 프로세서 )

PCI Express Generation 2

라이저 1

슬롯 1: x16 물리적 커넥터를 포함한 x8 링크 ,

9.5

인치 길이 , 표준 높이

슬롯 2: x8 물리적 커넥터를 포함한 x4 링크 ,

로우 프로파일 , 표준 높이 브래킷 포함

시스템 보드

슬롯 3: x8 물리적 커넥터를 포함한 x8 링크 ,

로우 프로파일

슬롯 4: x8 물리적 커넥터를 포함한 x8 링크 ,

로우 프로파일

라이저 2

슬롯 5: x16 물리적 커넥터를 포함한 x8 링크 ,

9.5

인치 길이 , 표준 높이

슬롯 6: x16 물리적 커넥터를 포함한 x8 링크 ,

9.5

인치 길이 , 표준 높이

시스템시작하기 63

메모리

아키텍처

메모리 모듈 소켓

메모리 모듈 용량

최소 RAM

최대 RAM

드라이브

하드 드라이브

디스켓 드라이브

광학 드라이브

플래시 드라이브

1066MHz DDR3 레지스터된 ECC DIMM

240 핀 32 개

1GB, 2GB, 4GB, 8GB 또는 16GB RDIMM

( 용량에 따라 단일 , 이중 또는 4 중 등급 )

4GB( 프로세서당 )

주 : 응용프로그램을 실행하려면 최소 16GB 를

설치하는 것이 좋습니다 .

512GB(16GB RDIMM 사용 )

최대 6 개의 2.5

인치 내부 핫 스왑 가능 SAS,

SATA 또는 SSD 드라이브

외부 USB 1.44MB( 선택 사양 )

슬림라인 SATA DVD-ROM 또는 DVD+RW

드라이브 ( 선택 사양 ) 1 개

주 : DVD 장치는 데이터 전용입니다 .

내부 USB( 선택 사양 )

내부 이중 SD 모듈 ( 선택 사양 ) iDRAC6 Enterprise 카드를 포함한 vFlash

카드 ( 선택 사양 )

64

커넥터

후면

NIC

NIC(Management NIC)

직렬

USB

비디오 vFlash

시스템시작하기

RJ-45( 내장형 1GB NIC 용 ) 4 개 iDRAC6 Enterprise 카드에 있는

Management NIC 포트 ( 선택 사양 ) 1 개

9 핀 , DTE, 16550 호환

4 핀 4 개 , USB 2.0 호환

15 핀 VGA iDRAC6 Enterprise 카드에 있는 vFlash 메모

리 카드 슬롯 ( 선택 사양 ) 1 개

커넥터 ( 계속 )

전면

비디오

USB

내부

USB

SD

15

4

핀 2

VGA

개 , USB 2.0 호환

4 핀 1 개 , USB 2.0 호환

내부 SD 모듈 ( 선택 사양 ) 2 개

비디오

비디오 유형 iDRAC6 을 포함한 내장형 Matrox G200

비디오 메모리 8MB(iDRAC 공유 )

전원

AC 전원 공급 장치

와트 ( 전원 공급 장치당 )

전압 ( 전원 공급 장치당 )

시스템 열 손실

최대 유입 전류

( 전원 공급 장치당 )

전지

시스템

RAID

전지

전지 ( 선택 사양 )

1100W

100-240V, 50/60Hz, 자동 범위 설정

4012BTU/Hr

일반적인 라인 상태 및 전체 시스템의 주변

작동 범위에서는 유입 전류가 10ms 이하인

동안 전원 공급 장치마다 55A 에 달할 수 있

습니다

CR 2032 3.0V 리튬 코인 셀

3.7V 리튬 이온

시스템시작하기 65

규격

높이

깊이

8.642cm(3.40

인치 )

44.05cm(17.34

인치 ) – 베젤 제외

48.24cm(18.99

인치 ) – 베젤 포함

72.06cm(28.37

인치 ) – 베젤 제외

75.56cm(29.75

인치 ) – 베젤 포함

26.1kg(57.54lb)

21.15kg(46.64lb)

무게 ( 최대 구성 시 )

무게 ( 비어 있을 경우 )

환경적 특성

주 : 특정 시스템 구성을 위한 환경 측정에 대한 자세한 내용은 www.dell.com/environmental_datasheets 를 참조하십시오 .

온도

작동

보관

10 ° ~ 35 ° C(50 ° ~ 95 ° F), 시간당 최고

10 ° C 의 온도 변화 기준

주 : 2,950 피트 이상의 고도에서 최대 작동 온

도는 1 ° F/550ft 로 감소됩니다 .

–40 ° ~ 65 ° C(–40 ° ~ 149 ° F), 시간당 최

고 20 ° C 의 온도 변화 기준

상대 습도

작동 20% ~ 80%( 비응축 ), 시간당 최고 10% 의

습도 변화 기준

5% ~ 95%( 비응축 ) 보관

최대 진동

작동

보관

5 ~ 350Hz 에서 15 분 동안 0.26G

3 ~ 200Hz 에서 15 분 동안 0.5G

66 시스템시작하기

환경적 특성 ( 계속 )

최대 충격

작동

보관

고도

작동

보관

공기 중 오염 물질 수준

등급

작동 방향으로 2.6ms 동안 (+) z 축으로 31G 의 충격 펄스 1 회

( 시스템 각 면에 1 회의 펄스 )

최대 2ms 동안 (+/-) x, y, z 축으로

71G 의 연속 충격 펄스 6 회

( 시스템 각 면에 1 회의 펄스 )

–16 ~ 3,048m(–50 ~ 10,000ft)

주 : 2,950 피트 이상의 고도에서 최대 작동

온도는 1 ° F/550ft 로 감소됩니다 .

–16 ~ 10,600m(–50 ~ 35,000ft)

ISA-S71.04-1985 의 규정에 따른 G2 이하

시스템시작하기 67

68 시스템시작하기

advertisement