Bigeyes BE-X9 User Manual

Add to My manuals
34 Pages

advertisement

Bigeyes BE-X9 User Manual | Manualzz

WiFi+GSM+RFID Smart Alarm System

User Manual

When designing, this system be added many amazing & practical new features, to make sure a better smart life.

Key Features

1. Pure WiFi version, WiFi+GSM version optional.

2. Android & iOS APP operation. User can do all settings via APP.

3. Support working with WiFi camera. The App integrated the IP camera's to realize the video record, send pic to user Email when

system alarm.

4. Support 10 remote controls, 24 wireless + 4 hardwired sensors.

5. Zone 1 to 16 can be customized the SMS text message content.

6. A powerful 20 slaves wireless smart home control lighting, appliances etc.

7. App detection system per 4 hours: AC power OK or not; system ARM OR DISARM. Accessories power lower or not; connect to panel or not.; Zone

has accessories or not... Check the all system clearly, get system status in time.

8. Support ADEMCO Contact ID Protocol. It can work with CMS (Central Monitor System).

9. Delay Alarm/External & Internal siren On/Off for any zone.

10. Low-voltage sensor/sensor-lost be monitored.

11. RFID tag to Arm/Disarm (optional)

Technical Information

1. Power supply: input AC=100~240V, output DC=12V

2. Static current: <50mA (when not in charging, excluding wired detectors)

3. Alarm current: <120mA (excluding wired siren)

4. GSM transmission power: 2W

5. WiFi frequency: 2.4G, built-in wireless internet protocol IEEE802.11b/g and TCP/IP protocol stack

6. WiFi receiving sensitivity: -86dbm; Emitting power: 18dbm

7. GSM frequency: 850/900/1800/1900MHz

8. Back-up battery: 3.7V/800mA; Standby time: 8 hours; Full charge time: 12 hours

9. Wireless receiving distance: >100 meters (open space)

10. Wireless transmission distance: >100 meters (open space)

11. Working condition: Temperature -10°C~70 °C, RH 5%~95%

1

Zones’Attribute Definition:

Zones’Type: 1 Defend Line, 2 Defend Line, 24-Hour defend Line

Defence Line 1: Which must pass Door window, balcony and boundary etc, which consists of wireless Door Sensor, Wireless Motion Sensor.

Defence Line 2: Which must pass Saloon, Lobby, Apartment and Living-Room etc. Which consists of Wireless Wide-Angle Motion Sensor.

24-Hours Defend Line: 24-Hour zones, This attribute can not be modiÞed. In arm or disarm or stay mode, once the sensor in these zones be triggered, system will alarm immediately, But not drive Siren. Which Consists of SOS Button, Wireless Gas Alarm, Wireless Somke Alarm.

Font Panel View

LCD Display

UP

Left

Right

Down

Conteol home appliances Call/#Confi rm

Set/Exit FRID

Away Arm

Home/Stay Arm

Disarm

SOS/Delete

2

Back Panel View

Button

DC 12V input jack

Button 12V output

(A: Arm disarm; S: SMS)

J12

S3

S+GND A+ NO COM

ON OFF

-BELL+ 34 33 32 31 -12V+

I/O connector

Wired Siren

Cable Slot

WiFi SET/Recover y

SIM Card Slot

Wired Connection

3

Arm/Disarm System

Notice

“xxxx” is the current user code, default user code is “1111”, and default admin/installer code is “1234”. The system is working with separate wireless

LCD/LED keypads, for activate and deactive operation, please refer to manual of wireless keypad.

Basic Alarm Setting

Enter into Setting Status

When system is in Disarm status, push then input admin code, default “1234”, press “OK” to enter into setting status.

System time setting

When system is in setting status, choose “Time Setting” to modify the current time. The time will back to default automatically once the alarm system is complete OFF.

Time Setting

Phone No.Setting

Time Setting

04:54:08

Activate Away Arm

In keypad, touch to activate Away Arm.

Remotely via SMS, send SMS content: xxxx+A0

Remotely via phone, make phone call to alarm system, after pick up, input xxxx#, you will hear "di" sound, press 1 to activate the Away Arm.

Time Setting

9/11/2013

Time Setting

THU

Activate Stay Arm

In keypad, touch to activate the Stay Arm

Remotely via phone, make phone call to alarm system, after pick up, input xxxx#, you will hear "di" sound, press 2 to active the Stay Arm

Disarm

In keypad, touch then, input xxxx+OK

Remotely via SMS, send SMS content: xxxx+A2

Remotely via phone, make phone call to alarm system, after pick up, input xxxx#, you will hear “di” sound, press 3 to disarm.

Press “OK” to select and “ ” to delete the default date, then enter with new time (XXhours, XXminute, XXsecond). Do same procedure for date. (XXDate, XXMonth, XXYear) Press “OK” and “ ◀▶ ” select the week, press “OK” to confiall settings.

Alarm Receiving Phone Number

This alarm system can totally preset up to 5 personal emergency phone numbers for alarm receiving.

4

Time Setting

Phone No.Setting

Phone Groups 1

Alarm Call >

Phone Groups 1

13800138000

·

Push “ ◀▶ ” toselect the Alarm Call or Alarm SMS, then push “OK”, you can input the number.

1st and 2nd group for setting Alarm SMS, 3rd group for setting Alarm SMS or Alarm Call, 4th&5th groups fot setting Alarm Call.

Basic Alarm Setting

Push “ ” you can delete the existing phone number.

You need touch “Ok” to save,and navigate into next phone number setting menu.

Notice: Maximum digitals fot phone number input is 15.

SMS Number for System System Status

The alarm system can preset one phone number for receiving SMS report of system’s status, including AC power recover, Arm/Disarm, Host Low Voltage,Sensor Low Voltage.

SMS Setting

Record

SMS Phone No.

13800138000

Host Low Volt

OFF >

AC Power Recover

OFF >

Sensor Low Volt

OFF >

Arm/Disarm SMS

OFF >

Push“ ”to delete exist phone number, enter new mobile phone number. Touch “OK” to save the phone number, it will navigate to event report selection. Touch “ ◀▶ ” to select enabled or disable the event report. AC power recover means when external enlectricity is recover, the alarm system will send SMS. Arm/Disarm SMS means when alarm system is Armed or Disarmed, the system will send SMS. Host Low Volt means when backup battery power is low, the system will send SMS. Sensor Low Volt means when battteries run out in wireless sensors, it will send SMS.

5

Basic Alarm Setting

Record Voice Memo

The system allows user to record up to 10 seconds voice memo. When alarm phone call is picked up, press “5” to listen the voice memo.

SMS Setting

Record

Recording Time

10

Record

OFF >

Basic Alarm Setting

Arm Delay

Alarm delay

Alarm Delay

10

Push “ ” to delete exist data, and input new seconds (e.g 10). lt accpet time between 00-59. push“OK” to save.

Notice: You need go to [Zone attribute] to enable which zones are belong to this function, therefore it can work.

Siren Setting

It allows siren time setting for each zone. The siren time can be set from

00-59 minutes. User can choose whether use built-in siren or not.

Push “ ◀▶ ” to choose “On” torecord voice, and push “OK” to start voice recording.

Arm Delay/Exit Delay

The Arm delay or exit delay can allow user to exit protected area before system is Armed. The time is adjustable from 00 to 59 seconds.

Siren Setting

Tone Setting

Siren Time

01

Zone No.

00

Built-in Siren

On >

Arm Delay

Alarm Delay

Arm Delay

10

Push “ ” to delete default data, and enter new time. push “OK” to save.

Push “ ” to delete the zone number, and input new zone number from

00-34. Touch “OK” to save

Push “ ” to delete the siren time, and input new siren time, “00” means disable. Default value is 01

Push “ ◀▶ ” to choose “On” to enable built-in siren, and touch “OK” to save.

Alarm Delay/Entry Delay

The alarm delay or entry delay can allow user to set alarm delay zones before system set alarm off. This allow user enter into specific detection area to disarm the system without triggering alarm.

6

Basic Alarm Setting

Tone setting

Tone setting means the alarm system will make “beep” sound, when detects system event, such as telephone line cut, Arm/Disarm,

Temperature Alert.

Siren Setting

Tone Setting

Push “ ◀▶

Arm/Disarm Tone

Off >

” to choose “OK” to save

Call in Setting

The system can receive the phone call via GSM. It allow user to set the ring times from 1 to 9. When the ring time reach to preset times, it will pick up the phone call for remotely control

Arm/Disarm Beep

Off >

Push “ ” to delete the zone number, and input new zone number from

00-30 and push “OK”. push “ ” to choose [program], then push “OK”, the LCD will display [programming]. Trigger the wireless sensors for two times, the LCD display [Success], push “OK” to save, you can continue to enroll more sensors.

Push “ ” to delete the zone number, and input new zone number from

00-30 and push “OK”. push “ ” to choose delete, the LCD will display

[Success], push”OK” to save. This will erase the current sensors in the zone from the alarm system.

Zone Attribute

The system has advanced zone attribute, it allow user to choose each of attribute for the zones, it helps user to customize the system, which can be more suitable fot speciÞc installation. Ensuring the zones with correct attribute, therefore sensors can work properly.

Call in Setting

Program&Delete

GSM Call in Tone

3

Zone Attribute

Upload

Zone No

00

Activate >

0 Defence Line >

00Help >

Alarm Delay Off >

Push “ ” to delete exist data. It accpets ring time between 1-9. Push

“OK” to save.

Program&Delete

Use this function to program/delete wireless sensors and accessories

(remote keyfob,wireless LED/LCD keypad). The wireless zone number is from 00-30. Zone 00 is for programming wireless remote keyfob or leypads.

Basic Alarm Setting

Zone Chime Off >

Smart Sensor Off >

Call in Setting

Program&Delete

Zone No

00

Program

Delete

Success

7

Basic Alarm Setting

Push “ ” to delete the zone number, and input new zone number from 00-30. push “OK” navigate to next menu. push “OK” you will navigate to last level menu.

Bypass Sensor: push “ ◀▶ ” to choose “Disable” to deactivate/bypass this zone.

Zone type: push “ ” to choose defense line, push “ ◀▶ ” to change the value from including 0, 1, 2.

Sensor type: push “ ” to choose sensor type, push “ ◀▶ ” to change the sensor type.

Alarm Delay: push “ ” to choose alarm delay off, push “ ◀▶ ”to enable or disable the alarm delay.

Zone Chime: push “ ” to choose zone chime off, push “ ◀▶ ” to enable or disable this function.

Smart Sensor Off: push “ ” to choose smart sensor off, push “ ◀▶ ” to enable or disable this function.

Notice:

[0 Defense line] means Þre, panic alarms, which are belong to 24 hours emergency zone. It will trigger the alarm system, even the system in disarm status.

[1 Defense line] means perimeter protection, which is belongto perimeter zone. lt will work when alarm system i n both AwayArm and Home Arm modes.

[2 Defense line] means interior protection, which is belong to motion zone. The sensors in this zone will be activated when system is in AwayArm mode, but will be de-activated, when system in Home Arm/Stay Arm mode.

Sensors Zone Number

00

01~05

06~14

15~24

25~28

29~32

Zone Type

N/A

Emergency Zone

Perimeter Zone

Motion Zone

Hardwired Zone

FRID

Sensor Type

Wireless Remote Keyfob

Wireless Sensors

Wireless Sensors

Wireless Sensors

8

Basic Alarm Setting

Default zone number for sensor and keyfob for standard alarm kit

Wireless Remote Wireless Door Sensor Wireless PIR motion Wireless Smoke

00 11 21 02

Upload

The system can either be used as self-monitoring system or monitored by security company. lt's compatible with ADEMC0 Contact ID protocol for alarm monitoring. lf you want to link the alarm system into alarm monitoring center, you need to do this operation. Moreover, the system not only upload alarm information, but also upload system's status to central monitoring station.

Zone Attribute Center Phone No. User Code Upload status

Upload 911 0001 Off

Push “ ” to delete exist number, and input new alarm monitoring centre number. Push “OK” to save, then navigate to next level menu, push “ ” to delete default user code, and input your user code, push

“OK”to save, then navigate to next level menu, touch " " to choose disable or enalbe upload status, push “OK” to save, navigate to next status selection menu.

Period Test

00000

AC Fail Upload Host Low Volt Sensor Low Volt Manual Test

Off > Off > Off > Off >

9

Basic Alarm Setting

User Code

Navigate to this menu, user can modify the user code. The user code with authorization for Arm/Disarm the system via keypad, SMS, phone call, mobile applications (APP). The default user code is “1111”

Password Setting

Pin Setting

Password Setting

####

Admin Code

Navigate to this menu, user can modify the admin code. The admin code with authorization for programming the system. The default admin code is

"1234"

Password Setting

Pin Setting

Pin Setting

#### push “ ”to delete the default time, and input new time e.g: 1200, push

“OK”to save and next time setting, it will navigate next day for auto arm/disarm setting.

Notice :

The time format should be 12:00, hours then minutes.

Wrong time input can not be saved.

How to use 12V relay Output

User arm the host by remote controller or host‘keyfob, the host also turn on 12V output at the same time; When Disarm, also turn off 12V output simultaneously. This funcation is convenient to allow user to corresponding appliances ( A Wire ports) .

The user also use the funcation by SMS under disarm, send 1111+C002 message to alarm, meaning turn on 12V relay , if sending 1111+C003 message to alarm, means turn off 12V reply (S Wire ports) appliances must be 12V Voltage

Resrt

Navigate to this menu, user can reset the alarm system. The system will reset to factory status. If user have done wrong programming, can not be solved, then you can use reset function. It will erase all the user's programming data.

Reset

Auto Arm/Disarm

Reset

Off >

Auto Arm/Disarm

This function can make the alarm system automatically Arm/Disarm in preset time for everyday.

Reset

Auto Arm/Disarm

SUN

--:-- Away Arm

10

How to use lntelligent home appliances

When user is in the office, on the shopping malls or outside. who wants to turn on the light and other corresponding appliances at home, the host can achieve what you want by remote SMS When user is at home who can operate the funcation by SMS or by host keyfob. The host which is with 8 wireless switch control function. Operation method is

Remarks: The funcation must match with wireless socket

SMS conmmand:

User Password+P11 means turn on No. 1 switch; User Password+P10 means turn off No.1 switch (Press host keyfob +11 turn on +10 turn off)

User Password+P21 means turn on No. 2 switch; User Password+P20 means turn off No.2 switch (Press host keyfob +21 turn on +20 turn off)

User Password+P31 means turn on No. 3 switch; User Password+P30 means turn off No.3 switch (Press host keyfob +31 turn on +30 turn off)

User Password+P41 means turn on No. 4 switch; User Password+P40 means turn off No.4 switch (Press host keyfob +41 turn on +40 turn off)

User Password+P51 means turn on No. 5 switch; User Password+P50 means turn off No.5 switch (Press host keyfob +51 turn on +50 turn off)

User Password+P61 means turn on No. 6 switch; User Password+P60 means turn off No.6 switch (Press host keyfob +61 turn on +60 turn off)

User Password+P71 means turn on No. 7 switch; User Password+P70 means turn off No.7 switch (Press host keyfob +71 turn on +70 turn off)

User Password+P81 means turn on No. 8 switch; User Password+P80 means turn off No.8 switch (Press host keyfob +81 turn on +80 turn off)

11

Alarm Handle for User

Receiving Alarm SMS

Once an alarm occurs, the system will send SMS as long as user choose for alarm SMS notification.

The system will send SMS with below content

(0001)Alarm System: 11 Zone Door Sensor Alarming

Inquiry System’s Status

The system allow user to inquiry the system’s status, send “User code + C” text message to alarm system, alarm will reply text message inform you whether it’s Armed or Disarmed

12

Alarm Handle for User

Receiving Alarm Phone Call

Once an alarm occurs, the system will make phone call as long as user choose for alarm call notiÞcation.The alarm systems support remotely control via phone call, including Away Arm/Stay Arm/Disarm, Onsite voice monitoring, listen voice message, talk back, two-way intercom, recording meno.

When pickup alarm phone call, you will hear the siren sound, after the replay, you can:

·

Press “2” on the phone to Stay Arm (lt will hang up immediately, system will be Stay Armed)

·

Press “4” on the phone to listen onsite voice (lt will hang up, after 20 seconds delay)

·

Press “6” on the phone to talk back (fixed phone number doesn't support this function)

·

13

How to Use Wireless Keyfob

Working LED

Disarm

Stay Arm

Away Arm

SOS

Program&Delete

Go to [Program&Delete] for programming wireless remote keyfob, program keyfobs in sequence into zone 00

Call in Setting

Program&Delete

Zone No.

00

Press “ ◀▶ ” to choose "Program", then press "OK" to conÞrm, the LCD display

[Programming], Now press the “ ”button for two times, the LCD will display

[Success], then touch "OK" to save.

Call in Setting

Program&Delete

Zone No.

00

Press “ ◀▶ " to choose "Delete", then press "OK" to conÞrm, the LCD will display

[Success], then to press "OK" to save.

Arm/Disarm/SOS

Away Arm the system:

Stay Arm the system:

Disarm the system:

Trigger SOS alarm:

14

How to Use Wireless Door Sensor

Introduction

Wireless door sensors or entry point sensors are the most reliable intrusion detection device for perimeter protection. The door sensor is adopting reed switch theory, it consists of wireless transmitter and magnetic two parts. When two parts sperate maximum 1 cm, the sensor will send alarm signal to ala rm system.

LED lndicator

Tamper Swtich

Program&Delete

Go to [Program&Delete] for programming wireless remote keyfob, program keyfob in sequence into zone 06~14.

Press “ ◀▶ " to choose "Program", then press "OK" to confirm, the LCD will display [Programming].

Now separate door sensor for two times, the LCD will display [Success], then press "OK" to save.

Call in Setting

Program&Delete

Zone No.

01

Press “ ◀▶ ” to choose “Delete” , then press “OK” to confirm, the LCD will display [Success]

RF transmitter

Panic button

Magnetic

Notice:

The door sensor in the package may differ from manual.

Battery

15

How to Use Wireless Door Sensor

Installation

·

Mount the transmitter on the door frame and the magnet on the door.

·

Make sure that the magnet will not be more than l cm from the transmitter.

·

Technical lnformation

·

·

·

·

30 μ A

40mA

Emitting frequency: 433MHz/(868MHz optional)

·

·

≤ 100m(Open space)

Lifespan of battery: ≤ 12 months

Notice:

The door sensor in the package may different from manual. The specification will change, when use different model of wireless door sensors.

16

How to Use Wireless PIR Sensor

Introduction

PIR motion sensor is one of common intrusion sensor for instruction detection. It with advantages of large space protection, lowest ener 9V consumption. It detects infrared energy changes which is caused by movement of human.

Program&Delete

Go to [Program&Delete] for programming wireless remote keyfob, program keyfob in sequence into zone 15~24.

Press " ◀▶ " to choose "Program", then touch "OK" to confirm, the LCD will display

[Programming].

Now trigger PIR sensor for two times, the LCD will display [Success], then touch

"OK" to save.

Call in Setting

Program&Delete

Zone No.

21

Press “ ◀▶ ” to choose “Delete”, then press “OK” to confirm, the LCD will display

[Success], then press “OK” to save.

1.Wide angle fresnel lens

2.Alarm LED lndicator

3.Swivel Bracket

17

How to Use Wireless PIR Sensor

Installation

Due to the wide coverage angle and the swivel bracket, the motion sensor can easily be installed:

·

Wall mounted on the wall and sensor points to entry point of doors

·

Technical Information

·

·

≤ 50 μ A

·

≤ 9.5mA

·

≤ 110 °

·

≤ 12m

Emitting frequency: 433MHz/(868MHz optional)

·

≤ 100m (Open space)

·

≤ 12 months

Notice:

The PIR sensor in the package may different from manual. The specification will change, when use different model of wireless PIR sensor.

18

Hardwired Zone Connection

Hardwired Zone Connection

Maintenance and Care

This alarm system is a Hi-Tech product with outstanding design and sophisticated technology. and shall be carefully.

·

Tr y to put the alarm panel in a dr y and well-ventilated location

· from curtailing the ser vice lives of electric parts and preventing the plastic shell from distorting.

· from touching them or the thieves from fi nding them

· with new batteries whenever you feel a sensor is not detecting properly.

19

20

APP Operation Instructions

21

22

23

24

25

26

27

28

29

30

31

32

33

advertisement

Related manuals

advertisement