YASKAWA VS-616G5 Series Owner's Manual
PDF
Dokument
Annons
Annons
PREFACE YASKAWA’s VS−616G5 is a user−friendly inverter provided with vector control for standard models in addition to V/f control. This instruction manual describes installation, maintenance and inspection, troubleshooting, and specifications of the VS−616G5. Read this instruction manual thoroughly before operation. YASKAWA ELECTRIC CORPORATION General Precautions S Some drawings in this manual are shown with the protective cover or shields removed, in order to describe detail with more clarity. Make sure all covers and shields are replaced before operating this product. S This manual may be modified when necessary because of improvement of the product, modification, or changes in specifications. Such modifications are denoted by a revised manual No. S To order a copy of this manual, if your copy has been damaged or lost, contact your YASKAWA representative. S YASKAWA is not responsible for any modification of the product made by the user, since that will void your guarantee. 2 NOTES FOR SAFE OPERATION NOTES FOR SAFE OPERATION Read this instruction manual thoroughly before installation, operation, maintenance or inspection of the VS−616G5. In this manual, NOTES FOR SAFE OPERATION are classified as ”WARNING” or ”CAUTION”. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury to personnel. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to personnel and damage to equipment. It may also be used to alert against unsafe practices. Even items described in CAUTION may result in a vital accident in some situations. In either case, follow these important notes. NOTE : These are steps to be taken to insure proper operation. RECEIVING CAUTION (Ref. page) S Do not install or operate any inverter which is damaged or has missing parts. Failure to observe this caution may result in personal injury or equipment damage. 10 3 INSTALLATION CAUTION (Ref. page) S Lift the cabinet by the base. When moving the unit, never lift by the front cover. Otherwise, the main unit may be dropped causing damage to the unit. . . . . . . . . . . 12 S Mount the inverter on nonflammable material (i.e. metal). Failure to observe this caution can result in a fire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 S When mounting units in an enclosure, install a fan or other cooling device to keep the intake air temperature below 45_C. Overheating may cause a fire or damage to the unit. . . . . . . . . . . . . . . . . . . . . . . . . 12 WIRING WARNING (Ref. page) S Only commence wiring after verifying that the power supply is turned OFF. Failure to observe this warning can result in an electrical shock or a fire. . . . . . . . . 17 S Wiring should be performed only by qualified personnel. Failure to observe this warning can result in an electrical shock or a fire. . . . . . . . . 17 S When wiring the emergency stop circuit, check the wiring thoroughly before operation. Failure to observe this warning can result in personal injury. . . . . . . . . . . . . . . . . . 17 S Make sure to ground the ground terminal before connecting the other terminals. Failure to observe this warning can result in an electrical shock. . . . . . . . . . . . . . . 21 4 NOTES FOR SAFE OPERATION CAUTION (Ref. page) S Verify that the inverter rated voltage coincides with the AC power supply voltage. Failure to observe this caution can result in personal injury or a fire. . . . . . . . . . . . 17 S Do not perform a withstand voltage test of the inverter. It may cause semi−conductor elements to be damaged. . . . . . . . . . . . . . . . . . . . . . . 17 S To connect a braking resistor, braking resistor unit or braking unit, follow the procedures described in APPENDIX 3. Improper connection may cause a fire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 S Tighten terminal screws to the specified tightening torque. Failure to observe this caution can result in a fire. . . . . . . . . . . . . . . . . . . . . . . . . . . 17 S Never connect the AC main circuit power supply to output terminals U, V and W. The inverter will be damaged and invalidate the guarantee. . . . . . . . . . . . . . . . . . 21 5 OPERATION WARNING (Ref. page) S Only turn ON the input power supply after replacing the front cover. Do not remove the cover while current is flowing. Failure to observe this warning can result in an electrical shock. . . . . . . . . . . . . . . 35 S When the retry function (L5−02) is selected, do not approach the inverter or the load, since it may restart suddenly after being stopped. (Construct machine system, so as to assure safety for personnel, even if the inverter should restart.) Failure to observe this warning can result in personal injury. . . . . . . . . . . . . . . . . . 35 S Since the stop button can be disabled by a function setting, install a separate emergency stop switch. Failure to observe this warning can result in personal injury. . . . . . . . . . . . . . . . . . 35 S If an alarm is reset with the operation signal ON, the inverter restarts automatically. Only reset the alarm after verifying that the operation signal is OFF. Failure to observe this warning can result in personal injury. . . . . . . . . . . . . . . . . . 35 CAUTION (Ref. page) S Never touch the heatsink or discharging resistor since the temperature is very high. Failure to observe this caution can result in harmful burns to the body. . . . . . . . . . 35 S Since it is easy to change operation speed from low to high speed, verify the safe working range of the motor and machine before operation. Failure to observe this caution can result in personal injury and machine damage. . . 35 S Install a holding brake separately if necessary. Failure to observe this caution can result in personal injury. S Do not change signals during operation. The machine or the inverter may be damaged. . . . . . . . . . . . . . . . . . . 35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 S All the constants of the inverter have been preset at the factory. Do not change the settings unnecessarily. The inverter may be damaged. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 6 NOTES FOR SAFE OPERATION MAINTENANCE AND INSPECTION WARNING (Ref. page) S Never touch high−voltage terminals in the inverter. Failure to observe this warning can result in an electrical shock. . . . . . . . . . . . . . . 60 S Replace all protective covers before powering up the inverter. To remove the cover, make sure to disconnect supply mains. Failure to observe this warning can result in an electrical shock. . . . . . . . . . . . . . . 60 S Perform maintenance or inspection only after verifying that the CHARGE LED goes OFF, after the main circuit power supply is turned OFF. The capacitors are still charged and can be dangerous. . . . . . . . . . . . . . . . . . . . . . . 60 S Only authorized personnel should be permitted to perform maintenance, inspections or parts replacement. [Remove all metal objects (watches, bracelets, etc.) before operation.] (Use tools which are insulated against electrical shock.) Failure to observe this warning can result in an electrical shock. . . . . . . . . . . . . . . 60 CAUTION (Ref. page) S The control PC board employs CMOS ICs. Do not touch the CMOS elements. They are easily damaged by static electricity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 S Do not connect or disconnect wires or connectors while power is applied to the circuit. Failure to observe this caution can result in personal injury. . . . . . . . . . . . . . . . . . . 60 S When removing the wiring, remove the ground wire last. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 OTHERS WARNING S Never modify the product. Failure to observe this warning can result in an electrical shock or personal injury and will invalidate the guarantee. 7 WARNING LABEL A warning label is displayed on the front cover of the inverter, as shown below. Follow these instructions when handling the inverter. Warning Label Model CIMR−G5C51P5 Warning Label WARNING May cause injury or electric shock. S Please follow the instructions in the manual before installation or operation. S Disconnect all power before opening front cover of unit. Wait 5 minutes until DC Bus capacitors discharge. S Use proper grounding techniques. AVERTISSMENT Risque de blessure ou décharge électrique. S Faites attention au mode d’emploi avant d’installer et mettre en marche. S Débranchez le courant avant d’ouvrir la couverture d’avant. Attendez 5 minutes jusqu’à les condensateurs de DC Bus sont déchargés. S Soyez à la masse Par une bonne technique. 8 CONTENTS NOTES FOR SAFE OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1 RECEIVING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.1 1.2 INSPECTION CHECKPOINTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 IDENTIFYING THE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2.1 2.2 2.3 2.4 REMOVING AND REPLACING THE DIGITAL OPERATOR . . . . . . . . . . . . . . . . . . . . 12 REMOVING AND REPLACING THE FRONT COVER . . . . . . . . . . . . . . . . . . . . . . . . . 14 CHOOSING A LOCATION TO MOUNT THE INVERTER . . . . . . . . . . . . . . . . . . . . . . 15 CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3 WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.1 3.2 3.3 3.4 3.5 CONNECTION DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 WIRING THE MAIN CIRCUIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 WIRING THE CONTROL CIRCUIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 CONFORMATION TO EMC STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 WIRING INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 4 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 4.1 4.2 4.3 OPERATION MODE SELECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 TEST RUN CHECKPOINTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 TEST RUN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 5 SETTING OPERATION CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 5.1 5.2 5.3 5.4 5.5 5.6 5.7 DIGITAL OPERATOR KEY DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 DIGITAL OPERATOR MODE SELECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 OPERATION MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 INITIALIZE MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 PROGRAMMING MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 MODIFIED CONSTANTS MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 MEMOBUS CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 6 MAINTENANCE AND INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 6.1 6.2 PERIODIC INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 PARTS REPLACEMENT SCHEDULE (GUIDELINES) . . . . . . . . . . . . . . . . . . . . . . . . . 61 7 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 7.1 7.2 FAULT DIAGNOSIS AND CORRECTIVE ACTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 MOTOR FAULTS AND CORRECTIVE ACTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 APPENDIX 1 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 APPENDIX 2 DIMENSIONS (mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 APPENDIX 3 TYPICAL CONNECTION DIAGRAM . . . . . . . . . . . . . . . . . . . . . . 71 3.1 3.2 3.3 3.4 BRAKING RESISTOR UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VS OPERATOR MODELS JVOP−95 AND JVOP−96 . . . . . . . . . . . . . . . . . . . . . . . . . SEQUENCE INPUT AND OUTPUT CONNECTION WITH NPN TRANSISTOR (0V COMMON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SEQUENCE INPUT AND OUTPUT CONNECTION WITH PNP TRANSISTOR (SUPPLY SIDE COMMON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 72 73 74 APPENDIX 4 CONSTANTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 9 1 RECEIVING CAUTION S Do not install or operate any inverter which is damaged or has missing parts. Failure to observe this caution may result in personal injury or equipment damage. This chapter describes how to verify the inverter after delivery to the user. 1.1 INSPECTION CHECKPOINTS (1) Receiving Checkpoints Table 1 Checkpoints Checkpoints Description Does the inverter model number correspond with Check the model number on the nameplate on the side of the the purchase order? VS-616G5. (Refer to page 11.) Are any parts damaged? Visually check the exterior and verify that there was no damage during transport. Is hardware properly seated and securely tightened? Remove inverter front cover. Check all visible hardware with appropriate tools. Was an instruction manual received? VS-616G5 Instruction manual (No.: TOE-S616-10.13) VS-616G5 Descriptive manual for constants (No.: TOEZ-S616-10.11) If any of the above checkpoints are not satisfactory, contact your YASKAWA representative. (2) Checking the Nameplate Data (a) Nameplate Data Example of European model CIMR−G5C51P5 Inverter Model Input Spec. Output Spec. Lot No. MODEL : CIMR − G5C51P5 INPUT : AC 3PH 500 − 600 V 50/60Hz 4.3A OUTPUT : AC 3PH 0 − 400Hz 0 − 600 V VARIABLE TORQUE CONT. 3.9 A PRG: CONSTANT TORQUE CONT. 3.5 A MASS: 4.0kg LOT NO SER NO : : YASKAWA ELECTRIC CORPORATION Fig. 1 Nameplate Data 10 SPEC : 51P51A E131457 MS Inverter Spec. Prg. No. Mass Serial No. UL File No. 1 RECEIVING (b) Model Designation CIMR − G5 C 5 1P5 Inverter VS − 616G5 Series Symbol C Specifications Europe use Symbol 5 Voltage 3−phase 575 V class Symbol 1P5 2P2 to 015 Max. applicable motor output 1.5 kW 2.2 kW to 15 kW Fig. 2 Model Designation (c) Specification Designation 5 1P5 1 A * Symbol 5 Symbol 1P5 2P2 to 015 Voltage 3−phase 575 V class Max. applicable motor output 1.5 kW 2.2 kW to 15 kW Revision symbol Symbol 0 Enclosure Open chassis type 1 Enclosed wall−mounted type (IP20) * For special specifications, a spec. sheet No. appears on the nameplate. Fig. 3 Specification Designation 1.2 IDENTIFYING THE PARTS Protective Cover (top/bottom) 4−Mounting Holes Front Cover Digital Operator JVOP−130 Heatsink Nameplate Ventilation Slots Fig. 4 Configuration of VS−616G5 (Model CIMR−G5C51P5) 11 2 INSTALLATION CAUTION S Lift the cabinet by the base. When moving the unit, never lift by the front cover. Otherwise, the main unit may be dropped causing damage to the unit. S Mount the inverter on nonflammable material (i.e. metal). Failure to observe this caution can result in a fire. S When mounting units in an enclosure, install a fan or other cooling device to keep the intake air temperature below 45_C. Overheating may cause a fire or damage to the unit. This chapter describes the configuration, location and space when mounting the VS−616G5. 2.1 REMOVING AND REPLACING THE DIGITAL OPERATOR Remove and replace the digital operator as follows. (1) Removing the Digital Operator Push the digital operator lever in the direction shown by arrow 1 and lift the digital operator in the direction shown by arrow 2 to remove the digital operator from the front cover. 2 Front Cover Digital Operator 1 Fig. 5 Removing the Digital Operator 12 2 INSTALLATION (2) Replacing the Digital Operator Digital Operator 2 1 Engage the digital operator on claws A in the direction shown by arrow 1 and then on claws B in the direction shown by arrow 2 to lock the digital operator. Front Cover Claws A Claws B Fig. 6 Replacing the Digital Operator NOTE Never fit the digital operator in any other direction or by any other method. The digital operator will not be connected to the inverter. 13 2.2 REMOVING AND REPLACING THE FRONT COVER To remove the front cover, first move the digital operator in the direction shown by arrow 1. (See Par. 2.1.) Then squeeze the cover in the direction shown by arrows 2 on both sides and lift in the direction shown by arrow 3. 1 Front Cover 2 3 2 Fig. 7 Removing and Replacing the Front Cover NOTE 14 Do not replace the front cover with the digital operator connected. The digital operator will not be connected to the inverter. Replace the front cover first and then install the digital operator on the cover. See Par. 2.1 for replacing the digital operator. 2 2.3 INSTALLATION CHOOSING A LOCATION TO MOUNT THE INVERTER To ensure proper performance and long operating life, follow the recommendations below when choosing a location for installing the VS−616G5. Make sure the inverter is protected from the following conditions: V Extreme cold and heat. Use only within ambient temperature range: −10_C to +40_C V Rain, moisture. V Oil sprays, splashes V Salt spray. V Direct sunlight. (Avoid using outdoors.) V Corrosive gases or liquids. V Dust or metallic particles in the air. (For enclosed wall−mounted type) V Physical shock, vibration. V Magnetic noise. (Example: welding machines, power devices, etc.) V High humidity. V Radioactive materials. V Combustibles: thinners, solvents, etc. Climatic condition for temperature, humidity and air pressure should be 3K3 (prEN50178). 15 2.4 CLEARANCES Install the VS−616G5 vertically and allow sufficient clearances for effective cooling as shown in Fig. 8. * Air 50 mm or more 120 mm or more 30 mm or more 30 mm or more * 120 mm or more Air 50 mm or more (a) Front View (b) Side View Fig. 8 Clearances NOTE 16 1. The clearances required at top/bottom and both sides are common in open chassis type (IP00) and enclosed wall−mounted type (IP20). 2. Remove the top and bottom covers to use the open chassis type of 15 kW or less. 3. For the external dimensions and mounting dimensions, refer to APPENDIX 2 “DIMENSIONS.” 4. Allowable intake air temperature to the inverter: Open chassis type : −10_C to +45_C Enclosed wall−mounted type : −10_C to +40_C 5. Ensure sufficient space for the sections at the upper and lower parts marked with ∗ in order to permit the flow of intake/exhaust air to/from the inverter. 3 3 WIRING WIRING WARNING S Only commence wiring after verifying that the power supply is turned OFF. Failure to observe this warning can result in an electrical shock or a fire. S Wiring should be performed only by qualified personnel. Failure to observe this warning can result in an electrical shock or a fire. S When wiring the emergency stop circuit, check the wiring thoroughly before operation. Failure to observe this warning can result in personal injury. CAUTION S Verify that the inverter rated voltage coincides with the AC power supply voltage. Failure to observe this caution can result in personal injury or a fire. S Do not perform a withstand voltage test of the inverter. It may cause semi−conductor elements to be damaged. S To connect a braking resistor, braking resistor unit or braking unit, follow the procedures described in APPENDIX 3. Improper connection may cause a fire. S Tighten terminal screws to the specified tightening torque. Failure to observe this caution can result in a fire. This chapter describes the main circuit wiring and the control circuit wiring of the VS−616G5. 17 3.1 CONNECTION DIAGRAM Below is a connection diagram of the main circuit and control circuit. Using the digital operator, the motor can be operated by wiring the main circuit only. DC Reactor (Option) Braking Resistor Unit (Option) Short−circuit Bar Fuse Line Filter MCCB 1 © ¨1 ¨2 L1(R) 3−Phase L1 Power Supply 500 to 600V L2 50/60 Hz L3 L2(S) L3(T) B1 VS−616G5 B2 U (T1) Motor V (T2) IM W (T3) PE Forward Run/Stop Factory Setting 2 Reverse Run when CLOSED 3 Fault Reset Multi−step Speed Setting 1 (Master/Aux Change) 5 Multi−step Speed Setting 2 6 Jog Reference 7 External Baseblock 8 35 36 2kΩ 4 to 20 mA 0 to +10 V 0V P P Multi−function Analog Output −10 to +10 V (Output Current at Factory − Setting, 5 V / Inverter Rated Current) 21 Analog Monitor 1 22 Sequence Common Terminal (0V) E +24V 18 Shield Sheath Connecti 19 TerminalPower 15 Freq. Setting Supply 15 V 20 mA 20 13 Master Freq. Ref. −10 to +10V (20kΩ) 9 14 Master Freq. Ref. 4 to 20 mA (250Ω) 10 on 0 to +10 V + AM Multi−function Contact Input E 2kΩ 23 Analog Monitor 2 4 11 Master Frequency Reference 3 1 Forward Run when CLOSED Reverse Run/Stop External Fault 16 Multi−function Analog Input −10 to +10V (20kΩ) P Multi−function Analog Output −10 to +10V − FM + (Output Frequency at Factory Setting, 0 to 10 V / 100% Frequency) 2 Fault Contact Output Contact Capacity: 250 VAC 1A or less 30 VDC 1A or less Multi−function Contact Output 250 VAC 1 A or less 30 VDC 1 A or less (Signal during Running at Factory Setting) 17 0V 25 33 Frequency Setting Power Supply −15V 20 mA 37 40 P Serial Communication RS−422/485 41 42 P 43 Model CIMR−G5C57P5 Fig. 9 Connection Diagram 18 27 26 Opto−coupler Output 1 (Zero Speed Signal at Factory Setting) Opto−coupler Output 2 (Speed Agree Signal at Factory Setting) Multi−function Open Collector Output 48 V 50 mA or less 3 WIRING Circuit Descriptions Refer to the numbers indicated in the diagram on the left. NOTE 1 These circuits are hazardous and are separated from accessible surfaces by protective separation. 2 These circuits are separated from all other circuits by protective separation consisting of double and reinforced insulation. These circuits may be interconnected with SELV (or equivalent) or non−SELV circuits, but not both. 3 These circuits are not separated from hazardous circuits by protective separation, but only with basic insulation. These circuits cannot be accessed and must not be interconnected with any circuits which are accessible, unless they are isolated from accessible circuits by supplemental insulation. Layout of control circuit terminals E ª 11 35 36 13 14 15 16 17 33 25 27 26 1 2 3 4 5 6 7 8 21 22 23 37 42 43 40 41 E ª 18 19 20 9 10 19 NOTE indicates shielded wires and 1. 2. Either control circuit terminal 13 or 14 can be used. (For simultaneous inputs, the two signals are added internally.) 3. Control circuit terminal 15/33 of +15 V/−15 V has a maximum output current capacity of 20 mA. 4. Multi−function analog output should be used for monitoring meters (e.g. output frequency meter) and should not be used for feedback control system. Use analog monitor cards (Model AO−08 or AO−12) for the control system, for a more accurate signal. 5. When using a braling resistor unit, set the constant L3−04 to “0” (stall prevention level during decel is “disabled”). If it is not changed, the motor may not stop within the set decel time. 6. When using model ERF braking resistor (inverter−mounted type), set the braking resistor protection selection to “enabled”. If it is not changed, the braking resistor cannot be protected. 7. When installing a DC reactor (optional for models of 15 kW or below), remove the short− circuit bar between ¨1 and ¨2 terminals and connect a DC reactor with the terminals. 8. Select RS−422 or RS−485 of serial communication (terminals 40 to 43) by using the dip switch on the control PC board. The terminal functions differ between RS−422 and RS−485. Table 2 Functions of RS−422 and RS−485 Terminal No. 40 41 42 43 20 indicates twisted−pair shielded wires. RS−422 Receiver R+ R− Driver S+ S− RS−485 Receiver/ R+/S+ Driver R−/S− Receiver/ R+/S+ Driver R−/S− 3 3.2 WIRING WIRING THE MAIN CIRCUIT WARNING S Make sure to ground the ground terminal before connecting other terminal. Failure to observe this warning can result in an electrical shock or a fire. CAUTION S Never connect the AC main circuit power supply to output terminals U, V and W. The inverter will be damaged and invalidate the guarantee. (1) Wiring Precautions for Main Circuit Input (a) Installation of Mains Fuses An input fuse is not provided with VS−616G5. Make sure to connect fuses between the AC main circuit power supply and VS−616G5 input terminals L1, L2 and L3 to protect the input diode or cables. S Input diode protection A semiconductor protection fuse is recommended to protect the input diode when a short−circuit occurs in the inverter. Table 3 shows the recommended fuse specificatons. Another fuse can be applied if I2t is smaller than that in the table and rated current is larger than inverter input current shown in the table. S Cable protection General fuse can be applied for cable protection. Follow the local safety regulation for selection. Select the fuse whose rated current is larger than the inverter input current shown in Table 3. 21 Table 3 Input Fuse Selection Inverter Fuse Max. Applicable Motor Output (kW) Rated Input Current (A) Rated Current (A) I2t max. (A2s) (at 575V) V 1.5 4.3 35 260 700 A70P35 2.2 5.1 35 260 700 A70P35 3.7 7.7 35 260 700 5.5 12.1 50 520 700 7.5 15.4 50 520 700 11 21 70 1040 700 A70P70 15 28 70 1040 700 A70P70 Manufacturer GOULD SHAWMUT Type A70P35 A70P50 A70P50 Note: Select the fuse whose specifications are more than rated current and less than I2t when using a fuse other than in the table. (b) Installation of Ground Fault Interrupter When connecting a ground fault interrupter to input terminals L1, L2 and L3, select one that is not affected by high frequency. (c) Installation of Magnetic Contactor When the main circuit power supply is shut OFF in the sequence, a magnetic contactor (MC) can be used instead of a molded−case circuit breaker (MCCB). However, when a magnetic contactor is switched OFF at the primary side, regenerative braking does not function and the motor coasts to a stop. S The load can be operated/stopped by opening/closing the magnetic contactor at the primary side. However, frequent switching may cause the inverter to malfunction. S When using a braking resistor unit, use a sequencer to break power supply side on overload relay trip contact. If the inverter malfunctions, the braking resistor unit may be burned out. (d) Terminal Block Connection Sequence Input power supply phases can be connected to any terminal regardless of the order of L1, L2 and L3 on the terminal block. (e) Installation of Line Filter Install an input line filter to reduce EMC noise. For specifications of the line filter, refer to Par. 3.4. 22 3 (f) WIRING Installation of Reactor When connecting an inverter (15 kW or less) to a large capacity power supply transformer (600 kVA or more), or when switching a phase advancing capacitor, excessive peak current flows in the input power supply circuit, which may damage the converter section. In such cases, install a DC reactor (optional) between inverter ¨1 and ¨2 terminals or an AC reactor (optional) on the input side. Installation of a reactor is effective for improvement of power factor on the power supply side. (g) Installation of Surge Suppressor For inductive loads (magnetic contactors, magnetic relays, magnetic valves, solenoids, magnetic brakes, etc.) connected near the inverter, use a surge suppressor simultaneously. (h) Prohibition of Installation of Phase Advancing Capacitor If a phase advancing capacitor or surge suppressor is connected in order to improve the power factor, it may become overheated and damaged by inverter high harmonic components. Also, the inverter may malfunction because of overcurrent. (2) Wiring Precautions for Main Circuit Output (a) Connection of Terminal Block and Load Connect output terminals U(T1), V(T2) and W(T3) to motor lead wires U(T1), V(T2) and W(T3). Verify that the motor rotates in the forward direction (CCW: counterclockwise when viewed from the motor load side) with the forward run command. If the motor rotation is incorrect, exchange any two of output terminals U(T1), V(T2) or W(T3). (b) Strict Prohibition of Connection of Input Power Supply to Output Terminals Never connect the input power supply to output terminals U(T1), V(T2) and W(T3). (c) Strict Prohibition of Short Circuiting or Grounding of Output Circuit Never touch the output circuit directly or put the output line in contact with the inverter case. Otherwise, it may cause an electrical shock or grounding. In addition, never short circuit the output line. (d) Prohibition of Connection of Phase Advancing Capacitor or LC/RC Line Filter Never connect a phase advancing capacitor or LC/RC line filter to the output circuit. (e) Avoidance of Installation of Magnetic Starter Do not connect a magnetic starter or magnetic contactor to the output circuit. If the load is connected while the inverter is running, the inverter overcurrent protective circuit operates because of inrush current. 23 (f) Installation of Thermal Overload Relay An electronic overload protective function is incorporated into the inverter. However, connect a thermal overload relay when driving several motors with one inverter or when using a multi−pole motor. When using a thermal overload relay, set inverter constant L1−01 to 0 (motor protection selection: disabled). Additionally, for thermal overload relay, at 50 Hz set the same rated current value as that described on the motor nameplate, or at 60 Hz 1.1 times larger than the rated current value described on the motor nameplate. (g) Wiring Distance between Inverter and Motor If the total wiring distance between inverter and motor is excessively long and the inverter carrier frequency (main transistor switching frequency) is high, harmonic leakage current from the cable will adversely to affect the inverter and peripheral devices. If the wiring distance between inverter and motor is long, reduce the inverter carrier frequency as described below. Carrier frequency can be set by constant C6−01. Table 4 Wiring Distance between Inverter and Motor Wiring Distance between Inverter and Motor Up to 20m More than 20m Carrier Frequency (Set value of constant C6−01) 10 kHz or less (10.0) 5 kHz or less (5.0) (3) Grounding S Never ground the inverter in common with welding machines, motors, or other large−current electrical equipment. Run all the ground wires in a conduit separate from wires for large−current electrical equipment. S Use the ground wires described in Table 6 and keep the length as short as possible. S When using several inverter units side by side, ground the units as shown in Fig. 10, (a). Do not loop the ground wires as shown in (b). (a) Acceptable Fig. 10 24 Grounding of Three Inverter Units (b) Not Acceptable 3 WIRING (4) Functions of Main Circuit Terminals The following table outlines the functions of the main circuit terminals. Wire according to each terminal function. Table 5 Terminal Functions Model CIMR−G5CV 51P5 52P2 53P7 55P5 57P5 5011 5015 Max Applicable M Motor Output O 1 5 kW 1.5 2 2 kW 2.2 3 7 kW 3.7 5 5 kW 5.5 7 5 kW 7.5 11 kW 15 kW L1(R) L2(S) Main circuit input p ppower supply pp y L3(T) U(T1) V(T2) Inverter output W(T3) B1 B2 Braking resistor unit © ¨1 S DC reactor (¨ 1 − ¨ 2) S DC bus terminals (¨ 1 − ©) ¨2 Ground terminal 25 (5) Main Circuit Configuration CIMR−G5C51P5 : B1 B2 ¨1 ¨2 (DCL Option) [ L1(R) L2(S) U(T1) + V(T2) L3(T) W(T3) © Control Circuit Power Supply (RCC) CIMR−G5C52P2 to 5015 B1 B2 : ¨1 ¨2 (DCL Option) [ L1(R) L2(S) U(T1) V(T2) + L3(T) W(T3) © Power Supply (RCC) Control Circuit Cooling Fan * The wiring has been completed at the factory prior to shipping. [ When installing a DC reactor (option) on models of 15 kW or below, remove the short−circuit bar between ¨1 and ¨2 terminals and connect a DC reactor with the terminals. 26 3 WIRING (6) Parts Required for Wiring Select wires or closed−loop connectors to be used for wiring from Tables 6 and 7. Table 6 Circuit Wire Size Model CIMR− Terminal Symbol Terminal Screw Wire Size* mm2 G5C51P5 L1(R), L2(S), L3(T), ©, ¨1, ¨2, B1, B2, U(T1), V(T2), W(T3) M4 2 − 5.5 G5C52P2 L1(R), L2(S), L3(T), ©, ¨1, ¨2, B1, B2, U(T1), V(T2), W(T3) M4 2 − 5.5 G5C53P7 L1(R), L2(S), L3(T), ©, ¨1, ¨2, B1, B2, U(T1), V(T2), W(T3) M4 G5C55P5 L1(R), L2(S), L3(T), ©, ¨1, ¨2, B1, B2, U(T1), V(T2), W(T3) M4 G5C57P5 L1(R), L2(S), L3(T), ©, ¨1, ¨2, B1, B2, U(T1), V(T2), W(T3) M4 Main G5C5011 G5C5015 Control Common to all models L1, L2, L3, ©, ¨1, ¨2, B1, B2, U, V, W L1, L2, L3, ©, ¨1, ¨2, B1, B2, U, V, W M5 M6 M5 M6 1 − 43 −− E M3.5 2 − 5.5 3.5 − 5.5 3.5 − 5.5 5.5 3.5 − 5.5 5 5 − 14 5.5 8 − 14 5.5 − 14 stranded 0.5 − 1.25 solid 0.5 − 1.25 0.5 − 2 * Wire size is determined using 75°C temperature - rated copper wire. When connecting a braking resistor unit or a braking unit, select wire size referring to the instructions of braking resistor unit and braking unit (manual No.:TOE - C726 - 2). 27 Table 7 Closed−Loop Connectors Wire Size mm2 05 0.5 0 75 0.75 1 25 1.25 2 3 5 / 5.5 3.5 55 8 14 22 30 / 38 50 / 60 80 100 Terminal Screw Closed−Loop Connectors M3.5 1.25 − 3.5 M4 1.25 − 4 M3.5 1.25 − 3.5 M4 1.25 − 4 M3.5 1.25 − 3.5 M4 1.25 − 4 M3.5 2 − 3.5 M4 2 −4 M5 2 −5 M6 2 −6 M8 2 −8 M4 5.5 − 4 M5 5.5 − 5 M6 5.5 − 6 M8 5.5 − 8 M5 8 −5 M6 8 −6 M8 8 −8 M6 14 − 6 M8 14 − 8 M6 22 − 6 M8 22 − 8 M8 38 − 8 M8 60 − 8 M10 60 − 10 M10 100 150 100 − 12 M12 200 325 28 80 − 10 100 − 10 150 − 12 200 − 12 M12 × 2 325 − 12 M16 325 − 16 3 NOTE WIRING When determining wire size, consider voltage drop. Select a wire size so that voltage drop will be less than 2% of the normal rated voltage. Voltage drop is calculated by the following equation: Phase−to−phase voltage drop (V) = 3 ¢ wire resistance (Ω/km) ¢ wiring distance (m) ¢ current (A) ¢ 10−3 (7) Recommended Cable Gland When installing the inverter unit as enclosed wall−mounted type (IP20), use the cable gland listed below or equivalent. Cable gland: SKINTOP ST or SKINTOP STE manufactured by LAPP. Blind cap BLK ::: SKINDICHT manufactured by LAPP. DP− :::: DP HOLE PLUG manufactured by HEYCO. Table 8 VS−616G5 VS 616G5 Model CIMR− Recommended Cable Gland Cable Lead−in Hole Cable Gland Diameter of Applicable Model Cable (mm) Model of Blind Cap Diameter (mm) Q’ty G5C51P5 to G5C53P7 35 1 STE21/29 18 to 25 DP−1375 28 2 ST21 13 to 18 DP−1093 G5C55P5 G5C57P5 35 22 44 35 22 3 1 2 1 1 STE21/29 ST13.5 ST29 STE21/29 ST13.5 18 to 25 6 to 12 18 to 25 18 to 25 6 to 12 DP−1375 DP−875 DP−1750 DP−1375 DP−875 G5C5011 G5C5015 29 3.3 WIRING THE CONTROL CIRCUIT The following table outlines the functions of the control circuit terminals. Wire according to each terminal function. (1) Functions of Control Circuit Terminals Table 9 Se uenc Seque nce Inpu put S Signal al Classification Terminal Forward run/stop Reverse run/stop 3 External fault input 4 Fault reset input Master/Auxiliary change (Multi−step speed reference 1) Multi−step speed reference 2 Jog reference External baseblock 0V for sequence input Sequence input internal common +24V for sequence input +15 V Power supply output −15 V Power supply output 5 6 7 8 11 35 36 Analo log IInput S Signal al 33 Sequen Seq enc nce e Ou utpu put Signal S al Description Signal Level Forward run when closed, stop when open Reverse run when closed, stop when open Fault when closed, normal state when open Reset when closed Auxiliary frequency reference when Multi−function contact closed inputs (H1−01 (H1 01 to H1−06) H1 06) Effective when closed Jog run when closed Inv. output stop when closed +15 V (Allowable current 20 mA max.) −15 V (Allowable current 20 mA max.) For analog command +15 V power supply For analog command −15 V power supply 16 Multi−function analog input 17 Common terminal for control circuit During running (NO contact) Closed when running Zero speed detection Closed at zero−speed zero speed level (b2 (b2−01) 01) or b l below Speed ag agree ee detect detection o Closed when the freq. reaches to ¦2 Hz off set freq. f Master frequency reference 14 10 25 27 26 37 18 19 20 Frequency meter output 22 Common 23 Current monitor 40 41 42 43 E Open collector output 48 V 50 mA or less * Dry y co contact tact C t t capacity: Contact it 250 VAC 1 A or less 30 VDC 1 A or less Multi−function analog monitor 1 (H4−01,H4−02) 0 to +10 V/100% freq. 0 to ¦10 V Max. M ¦5% 2 mA or less 5 V/inverter rated current −10 to +10 V (20 kΩ), 0 to +10 V (20 kΩ) 4 to 20 mA (250Ω) −10 to +10V (20kΩ), 0 to +10V (20kΩ) Dry contact Contact capacity: 250 5 VAC 1 A or less l 30 VDC 1 A or less Multi−function u t u ct o output F lt when Fault h closed l d bbetween t tterminals i l 18 and d 20 Fault au t contact co tact output (NO/NC ( O/ C co contact) tact) Fault when open between terminals 19 and 20 21 Photo−coupler Ph t l iinsulation l ti Input : +24 VDC 8 mA −10 to +10 V/−100% to +100% 0 to +10 V/100% 4 to 20 mA/100%, −10 to +10 V/−100% to +100%, 0 to +10 V/100% −10 to +10V/−100% to +100% Auxiliary analog input 0 to +10 V/100% (H3−05) 0V 13 9 Analog og Ou Output Signal al Signal Function 1 2 15 Ser erial Co Commu tion unicatio 2/485)) (RS RS−422 Control Circuit Terminals Multi−function analog monitor 2 (H4−04,H4−05) R+: Receiver (RS−422) R+/S+: Receiver/Driver (RS−485) R−: Receiver (RS−422) R−/S−: Receiver/Driver (RS−485) RS 422 or RS−485 RS−422 RS 485 can be selected by the dip switch on the control PC b d board. S+: Driver (RS−422) R+/S+: Receiver/Driver (RS−485) S−: Driver (RS−422) R−/S−: Receiver/Driver (RS−485) Connection to shield sheath of signal lead or optional unit grounding * When an inductive load such as a relay coil is driven, insert a fly−wheel diode as shown in the following figure. 30 3 WIRING Fly−wheel Diode External Power Supply 48 V or less E ª 1 Fig. 11 NOTE 50 mA or less 11 35 36 13 14 15 16 17 33 25 27 26 2 3 Fly−wheel diode rating should be of rated circuit voltage/current value or over. Coil 4 5 6 7 8 42 43 21 22 23 37 40 41 E ª 18 19 20 9 10 Control Circuit Terminal Arrangement Do not connect the wire to the terminal shown as . (2) Wiring the Control Circuit Terminals Screwdriver Blade Width 3.5 mm max 0.6 mm max Insert the wire into the lower part of the terminal block and connect it tightly with a screwdriver. Wire sheath strip length must be 7 mm. 7 mm (3) Precautions on Control Circuit Wiring S Separate control circuit wires 1 to 11, 13 to 23, 25 to 27, 33, 35 to 37, 40, to 43 and E from main circuit wires L1, L2, L3, B1, B2, U, V, W, ©, ¨1,¨ 2 and other power cables to prevent erroneous operation caused by noise interference. S Separate the wiring of control circuit terminals 9, 10, 18, 19 and 20 (contact output) from those of terminals 1 to 8, 11, 13 to 17, 21 to 23, 25 to 27, 33, 35 to 37, 40 to 43. S Use twisted shielded or twisted−pair shielded wire for the control circuit line and connect the shielded sheath to inverter terminal E. (See Fig. 12.) Wiring distance should be less than 50 m. Shielded Sheath To inverter shielded sheath terminal E Fig. 12 Armor Insulate these parts with insulating tape. Never connect. Shielded Wire Termination 31 3.4 CONFORMATION TO EMC STANDARDS In order to coform to EMC standards, the exclusive−use methods are required for line filter application, cable shielding and inverter installation. The following explains the outline of the methods. The line filter and the inverter must be mounted on the same metal plate. The filter should be mounted as close to the inverter as practical. Keep cable as short as possible. The metal plate should be securely grounded. The ground of line filter and inverter must be bonded to the metal plate with as much area as possible. For mains input cable, screened cable is recommended at least within the panel. The screen of the cable should be connected to a solid ground. For the motor cable, screened cable (max. 20 m) must be used and the screen of the motor cable is connected to ground at both ends by a short connection, using as large an area as practical. For more detailed explanation, refer to “Making YASKAWA Inverter Products Conform with EMC Directive” (EZZ006908). The following table and figures show the line filter list for EMC standards and the installation/wiring of inverter and line filter. Table 10 Inverter Model CIMR−G5C Line Filter List for EMC Standards Line Filter (manufactured by Schaffner) Model Rated Current (A) Mass (kg) Dimensions in mm W×D×H FS5492−18−07 18A 2.4 70×329×185 FS5492−42−07 42A 42 4.2 100×389×185 51P5 52P2 53P7 55P5 57P5 5011 5015 32 3 L3 L2 L1 WIRING PE Ground Bonds (Remove any paint.) Mains Inverter Filter Load L1 L2 L3 U V W Cable Length: Max. 40cm Metal Plate Motor Cable: Max. 20 m Ground Bonds (Remove any paint.) IM Fig. 13 Installation of Line Filter and Inverter (Models CIMR−G5C 51P5 to 5015) 33 3.5 WIRING INSPECTION After completing of installation and wiring, check for the following items. Never use control circuit buzzer check. V Wiring is proper. V Wire clippings or screws are not left in the unit. V Screws are securely tightened. V Bare wire in the terminal does not contact other terminals. 34 4 4 OPERATION OPERATION WARNING S Only turn ON the input power supply after replacing the front cover. Do not remove the cover while current is flowing. Failure to observe this warning can result in an electrical shock. S When the retry function (L5−02) is selected, do not approach the inverter or the load, since it may restart suddenly after being stopped. (Construct machine system, so as to assure safety for personnel, even if the inverter should restart.) Failure to observe this warning can result in personal injury. S Since the stop button can be disabled by a function setting, install a separate emergency stop switch. Failure to observe this warning can result in personal injury. S If an alarm is reset with the operation signal ON, the inverter restarts automatically. Only reset the alarm after verifying that the operation signal is OFF. Failure to observe this warning can result in personal injury. CAUTION S Never touch the heatsink or discharging resistor since the temperature is very high. Failure to observe this caution can result in harmful burns to the body. S Since it is easy to change operation speed from low to high speed, verify the safe working range of the motor and machine before operation. Failure to observe this caution can result in personal injury and machine damage. S Install a holding brake separately if necessary. Failure to observe this caution can result in personal injury. S Do not change signals during operation. The machine or the inverter may be damaged. S All the constants of the inverter have been preset at the factory. Do not change the settings unnecessarily. The inverter may be damaged. This chapter describes the basic operation procedures of the VS−616G5. 35 4.1 OPERATION MODE SELECTION The VS−616G5 has two operation modes, LOCAL and REMOTE, as described below. These two modes can be selected by the digital operator “LOCAL/REMOTE” key only while the operation is stopped. The selected operation mode can be verified by observing the digital operator SEQ and REF LEDs as shown below. The operation mode is set to REMOTE (run by control circuit terminals 13 and 14 frequency reference and run command from a control circuit terminal) prior to shipment. Multi−function contact inputs from control circuit terminals 3 to 8 are enabled in both operation modes LOCAL/REMOTE. S LOCAL : Both frequency reference and run command are set by the digital operator. SEQ and REF LEDs go OFF. S REMOTE : Master frequency reference and run command can be selected as described below. Table 11 Con− stant No. b1−01 b1−02 Reference Selection in REMOTE Mode Digital Operator Display Reference Source Run Source DRIVE FWD 36 REV SEQ Name Remarks Reference selection 0 : Master frequency reference from operator (d1−01) (Operator REF LED is OFF.) 1 : Master frequency reference from control circuit terminals 13 and 14 (Operator REF LED is ON.) 2 : Master frequency reference set by transmission (Operator REF LED blinks.) 3 : Master frequency reference set by option (Operator REF LED blinks.) Operation method selection 0 : Master frequency reference from operator (d1−01) (Operator REF LED is OFF.) 1 : Master frequency reference from control circuit terminals 13 and 14 (Operator REF LED is ON.) 2 : Master frequency reference set by transmission (Operator REF LED blinks.) 3 : Master frequency reference set by option (Operator REF LED blinks.) REMOTE REF ON, OFF or blinking 4 4.2 OPERATION TEST RUN CHECKPOINTS To assure safety, prior to initial operation, disconnect the machine coupling so that the motor is isolated from the machine. If initial operation must be performed while the motor is still coupled to the machine, use great care to avoid potentially hazardous conditions. Check the following items before a test run. V Wiring and terminal connections are correct. V No short circuit caused by wire clippings. V Screw−type terminals are securely tightened. V Motor is securely mounted. V All items are correctly earthed (grounded). 37 4.3 TEST RUN (1) Digital Operator Display at Power−up When the system is ready for operation, turn ON the power supply. Verify that the inverter powers up properly. If any problems are found, turn OFF the power supply immediately. The digital operator display illuminates as shown below when turning the power supply ON. DRIVE FWD REV SEQ REMOTE REF Frequency Ref Mode Indicator LED : DRIVE/REMOTE (SEQ, REF) LED ON Display Section : Displays frequency reference (corre− sponding to analog reference value) U1−01 = 0.00 HZ DIGITAL OPERATOR JVOP−130 LOCAL REMOTE JOG MENU ESC DATA ENTER FWD REV RUN Fig. 14 38 RESET STOP Digital Operator Display at Power−up Operation Indicator LED : STOP LED ON 4 OPERATION (2) Operation Check Points Check the following items during operation. V Motor rotates smoothly. V Motor rotates in the correct direction. V Motor does not have abnormal vibration or noise. V Acceleration and deceleration are smooth. V Current matches the load flow. V Status indicator LEDs and digital operator display are correct. (3) Example of Basic Operation (a) Operation by Digital Operator The diagram below shows a typical operation pattern using the digital operator. 5 Forward 6 7 60 Hz 2 1 6 Hz 3 4 Forward Forward Run Power ON Stop 15 Hz Reverse Run Reverse Forward Jog Run Fig. 15 Frequency Setting Frequency Reference Change 60 Hz Operation Sequence by Digital Operator 39 Table 12 Typical Operation by Digital Operator Description Key Sequence 1 Power ON Frequency Ref U1−01 = 0.00 HZ ⋅Displays frequency reference value. Operation Condition Setting ⋅Select LOCAL mode. 2 Forward Jog Run (6 Hz) ⋅JOG run procedure (Runs while depressing JOG key.) 3 Frequency Setting ⋅Change reference value. Digital Operator Display REMOTE LED OFF (SEQ, REF) LOCAL REMOTE JOG Frequency Ref 000.00 HZ DATA ENTER Digit to be changed blinks. Change the value by depressing Frequency Ref 015.00 HZ RESET DATA ENTER ⋅Write−in set value. ⋅Select output frequency monitor display. Entry Accepted Frequency Ref 015.00 HZ ESC Frequency Ref U1−01 = 15.00 HZ Output Freq U1−02 = 0.00 HZ 4 Forward Run ⋅Forward run (15 Hz) RUN Output Freq U1−02 = 15.00 HZ RUN LED lights. FWD LED lights. RUN (Cont’d) 40 4 Table 12 OPERATION Typical Operation by Digital Operator (Cont’d) Description Key Sequence Frequency Ref U1−01 = 015.00 HZ 5 Frequency Reference Value Change (15 Hz to 60 Hz) ⋅Select frequency reference value display. ⋅Change set value. Digital Operator Display DATA ENTER Frequency Ref 015.00 HZ Change the value by depressing Frequency Ref 060.00 HZ RESET ⋅Write−in set value. DATA ENTER Entry Accepted Frequency Ref 060.00 HZ ⋅Select output frequency monitor display. 6 Reverse Run ⋅Switch to reverse run. ESC Frequency Ref U1−01 = 60.00 HZ Output Freq U1−02 = 60.00 HZ FWD REV Output Freq U1−02 = −60.00 HZ REV LED lights. 7 Stop ⋅Decelerates to a stop. STOP Output Freq U1−02 = 0.00 HZ STOP LED lights. (RUN LED blinks during deceleration.) STOP 41 (b) Operation by Control Circuit Terminal Signal The diagram below shows a typical operation pattern using the control circuit terminal signals. Forward 5 60 Hz 1 3 2 4 6 Hz Reference Operation Power ON Forward Jog Run Fig. 16 42 Frequency Setting Operation Sequence by Control Circuit Terminal Signal Stop 4 Table 13 OPERATION Typical Operation by Control Circuit Terminal Signal Description 1 Power ON ⋅Displays frequency reference value. REMOTE mode is preset at the factory. Output Frequency Display ⋅Switch to output frequency display. 2 Forward Jog Run (6Hz) ⋅Close between control circuit terminals 1 and 11 with 7 and 11 closed to perform JOG run. ⋅Open between terminals 1 and 11, 7 and 11 after verifying normal operation. 3 Frequency Setting ⋅Input frequency reference voltage (current) by control circuit terminal 13 or 14 and verify the input value by the digital operator. Output Frequency Display ⋅Select output frequency monitor display. 4 Forward Run ⋅Close between control circuit terminals 1 and 11 to perform forward run. Key Sequence Digital Operator Display Frequency Ref U1−01 = 0.00 HZ REMOTE LED lights. (SEQ, REF) Output Freq U1−02 = 0.00 HZ Output Freq U1−02 = 6.00 HZ RUN LED lights. FWD LED lights. RUN Frequency Ref U1−01 = 60.00 HZ For reference voltage 10V Output Freq U1−02 = 0.00 HZ Output Freq U1−02 = 60.00 HZ RUN LED lights. FWD LED lights. RUN 5 Stop Output Freq U1−02 = 0.00 HZ ⋅Open between control circuit terminals 1 and 11 to stop operation. STOP LED lights. (RUN LED blinks during deceleration.) STOP 43 5 SETTING OPERATION CONDITIONS 5.1 DIGITAL OPERATOR KEY DESCRIPTION Mode Indicator LEDs Drive Mode Display Lights when selecting drive mode. OFF when selecting any mode other than drive mode. Rotating Direction Display FWD : Lights at forward run. REV : Lights at reverse run. Remote Mode DRIVE FWD REV Lights when selecting input mode from the control circuit terminal. SEQ : Lights when selecting run command from control circuit terminal. REF : Lights when selecting frequency reference from control circuit terminals 13 and 14. REMOTE SEQ REF Display Displays set values of each function or monitoring values such as frequency and output current. (2 lines ¢ 16 characters) Menu Key Displays the menu for mode selection. Escape Key Returns to the status entered before [DATA/ENTER] key was depressed. DIGITAL OPERATOR JVOP−130 Write/Read Key Selects mode, group, function or constant name. Displays each constant set value while displaying a constant name. By depressing this key again, the set value is written in. Menu/Number Change Keys LOCAL MENU Selects mode, group, function, constant name or set value. ∧ : Increment key ∨ : Decrement key ESC Digit Selection Key REMOTE Selects a digit of a set value to be changed. The selected digit blinks. (Resets operation at faults.) DATA JOG ENTER Operation Command Keys FWD REV Operation command keys operate the inverter. Enabled only in the drive mode. RESET RUN STOP * STOP : Red LED lights by depressing STOP. * RUN : Red LED lights by depressing RUN. FWD/REV : Selects forward or reverse run. JOG : Jog run is enabled while depressing this key. Operation Mode Selection Key * RUN or STOP LED changes in accordance with the following operations. The operation mode is alternated between REMOTE and LOCAL (digital operator). Inv. Output Frequency RUN STOP STOP Freq. Setting RUN LED STOP LED : ON : BLINKING D : OFF Fig. 17 44 Digital Operator Key Description Note : Only a digit that is blinking can be changed. 5 5.2 SETTING OPERATION CONDITIONS DIGITAL OPERATOR MODE SELECTION The digital operator of the VS−616G5 has the following four modes. Table 14 Digital Operator Modes Mode Description Opetation Inverter operation is enabled. Displays monitor value, fault trace or faults that occurred previously. Initialize Sets and reads language displayed on the digital operator, level to set/read constants and control method. Programming Sets/reads constants. Auto−tuning Motor−related constants necessary for vector control are automatically set. This mode is not displayed at V/f control or V/f control with PG feedback. Modified Constants Sets/reads constants changed from the values preset at the factory in programming mode or auto−tuning mode. The constants changed in initialize mode are not displayed. Depressing the [MENU] key displays “Operation”. Change the mode display by using key and select a mode by the [DATA/ENTER] key. Table 15 shows typical operation. or 45 Table 15 Description ⋅Displays Operation. Typical Operation of Mode Selection Key Sequence Digital Operator Display MENU ** Main Menu ** Operation ⋅Change the mode. (Displays Initialize.) ** Main Menu ** Initialize ⋅Change the mode. (Displays Programming.) ** Main Menu ** Programming ⋅Change the mode. (Displays Auto-Tuning.) ** Main Menu ** Auto−Tuning ⋅Change the mode. (Displays Modified Consts.) ** Main Menu ** Modified Consts ⋅Select Modified Consts. DATA ENTER ⋅Return the display to Modified Consts. ESC ⋅Change the mode. (Displays Operation.) Remarks Accel Time 1 C1−01 = 20.0 Sec Displays accel time and its setting when accel time (C1−01) has been changed. ** Main Menu ** Modified Consts ** Main Menu ** Operation The mode can be changed even during operation. Even if the mode is changed to the programming mode to set/read constants during operation, the inverter continues operation. The inverter does not operate even if the run command is input, when the programming mode is selected and the inverter is stopped. When the constants are set/read during operation, depress [MENU] key and then [DATA/ENTER] key to return to the frequency reference value display (the same as power−ON display). 46 5 5.3 SETTING OPERATION CONDITIONS OPERATION MODE The inverter can operate in this mode. Operation data or faults can be displayed. Each time when or key, an item to be monitored is changed. If any fault occurs, the digital depressing operator changes to the fault display automatically and returns to the previous display by the [> RESET] key. Table 16 Description POWER ON *1 Displays Operation. Select Operation. Typical Operation in Operation Mode Key Sequence Digital Operator Display MENU ** Main Menu ** Operation Remarks DATA ENTER Displays frequency reference value setting.*1 Frequency Ref U1−01 = 60.00 HZ Displays output frequency.*1 Output Freq U1−02 = 60.00 HZ Displays output current.*1 Output Current U1−03 = 12.3 A Displays output voltage.*1 *2 Output Voltage U1−06 = 575.0 VAC U2− VV *3 Function U2 Fault Trace U3− VV *3 Function U3 Fault History U1− VV *3 Function U1 Monitor To set frequency reference, depress the [DATA/ENTER] key. The value to be set blinks. (This setting is enabled at frequency reference from the digital operator or when using multi− step speed commands d1−01 to 09.) *1: Data to be displayed after the power supply ON can be selected by setting constant o1−02 (monitor selection after power up) among frequency reference value, output frequency, output current or selected monitor. (Initial setting is set to the output voltage monitor. ) *2: Another item to be displayed instead of output voltage can be selected by setting constant o1−01 (monitor selection). *3: For items to be displayed such as U1−jj, U2−jj and U3−jj, refer to Table A−3 “Monitor Constants List”. 47 (1) Changing Frequency Reference Value ( Example ) Frequency reference value is changed from 0.00 Hz to 60.00 Hz using the digital operator. Table 17 Description Changing Frequency Reference Value Key Sequence Digital Operator Display MENU ** Main Menu ** Operation Remarks The inverter is in the LOCAL mode. (Can be operated from the keypad. ) ⋅Displays Operation. ⋅Select Operation. (Displays frequency reference.) ⋅Depress [DATA/ENTER] key. The value to be set blinks. Frequency Ref U1−01 = 0.00 HZ DATA ENTER Frequency Ref 0 00.00 HZ DATA ENTER ⋅Change the value to 60.00Hz. RESET ⋅Write−in the constant. DATA ENTER Frequency Ref 0 6 0.00 HZ Entry Accepted Frequency Ref 0 6 0.00 HZ ESC Frequency Ref U1−01 = 60.00 HZ Note: Only the digit that is blinking can be changed. 48 Returns to the frequency reference value display after Entry Accepted is displayed for 1.5 seconds. 5 SETTING OPERATION CONDITIONS (2) Monitor Display ( Example ) Monitoring DC bus voltage (U1−07) during frequency reference display. Table 18 Description Typical Monitor Display Operation Key Sequence ⋅Displaying frequency reference. Function U1 Monitor DATA ENTER ⋅Displays U1−07. Frequency Ref U1−01 = 60.00 HZ DC Bus Voltage U1−07 = 776 VDC ⋅Returns to U1−VV display. ESC ⋅Returns to frequency reference display. Remarks Frequency Ref U1−01 = 60.00 HZ ⋅Displays U1−VV monitor. ⋅Select U1−VV. Digital Operator Display Function U1 Monitor Frequency Ref U1−01 = 60.00 HZ 49 (3) Fault Display When detecting a fault, the VS−616G5 displays the fault contents on the digital operator and activates fault contact output, the motor coasts to a stop. For the display at fault occurrence or troubleshooting, refer to Table 31 ”Fault Diagnosis and Corrective Actions”. Since the VS−616G5 stores the information obtained at fault occurrence in the inverter, the information can be verified. For details, refer to Table A−3 ”Monitor Constants List”. ( Example ) Verifying the status at fault occurrence and resetting the fault when overcurrent occurs during operation at 60.00 Hz. Table 19 Description Typical Operation of Fault Display Key Sequence ⋅Displaying frequency reference. Digital Operator Display Remarks Frequency Ref U1−01 = 60.00 HZ ⋅Overcurrent occurs. OC Over Current ⋅Verify the status at fault occurrence. Last Fault Over Current Frequency Ref U2−03 = 60.00 HZ Displays the fault. Displays the status immediately before the fault occurred. Output Freq U2−04 = 60.00 HZ Output Current U2−05 = 12.3 A ⋅Reset the fault. RESET NOTE 50 Frequency Ref U1−01 = 60.00 HZ By resetting the fault, the display entered just prior to the fault occurrence is returned. Fault reset cannot be activated while forward/reverse run signal from control circuit terminal is ON. Turn OFF the signal and check the safety of the sorrounding area, then reset the inverter. 5 5.4 SETTING OPERATION CONDITIONS INITIALIZE MODE As described below, the language displayed on the digital operator, the access level to set/read constants or control method (V/f control, vector control) can be selected. Set constants A1−01 and A1−02 before use of the VS−616G5. The following table shows the main constants for initialize mode. Table 20 Initialize Mode Con− stant No. Digital Operator Display Name A1−00 Select Language Language selection (change enable during run) A1−01 Access Level 0 : Exclusive for monitoring 1 : Constants for user selection (Constants to be set/read can be programmed by operator.) Access level 2 : QUICK−START (change enable during (Constants required for test run are set/read.) run) 3 : BASIC (Normally−used constants are set/read.) 4 : ADVANCED (All constants are set/read.) A1−02 Control Method Control method selection 0 : 1 : 2 : 3 : Init Parameters Reset to factory defaults. 0 1110 2220 3330 A1−04 Enter Password Password Password setting A2−01 to A2−32 User Param 1 to 32 User setting constant When A1−01=1 (user program) is selected, selects the constants that can be set/read by digital operator. : A1−03 : Description 0 : English 1 : Japanese V/f control V/f control with PG feedback Open loop vector Flux vector : : : : No Initialization Initialization of user setting 2−wire initialization 3−wire initialization :Do not set the constants unnecessarily, or the constants are initialized (A1−03) or some constants cannot be changed (A1−04). 51 (1) Changing Control Method ( Example ) The control method is changed from open loop vector to V/f control. Table 21 Description Changing Control Method Key Sequence ⋅Displaying frequency reference. ⋅Displays Operation. MENU DATA ENTER DATA ENTER 52 When selecting Initialize, Select Language is displayed. A1−02 = 02 *** Open Loop Vector A1−02 = 00 V/F Control DATA ENTER Entry Accepted MENU ** Main Menu ** Operation DATA ENTER Frequency Ref U1−01 = 60.00 HZ ⋅Return to Operation. ⋅Select Operation to display frequency reference. Select Language English Control Method Open Loop Vector ⋅Change the control method. (Displays V/F Control.) ⋅Select V/F Control. ** Main Menu ** Operation ** Main Menu ** Initialize ⋅Change the constant name. (Displays Control Method.) ⋅By depressing DATA/ENTER key, constant No. and set value are displayed. Remarks Frequency Ref U1−01 = 60.00 HZ ⋅Displays Initialize. ⋅Select Initialize. Digital Operator Display After displaying Entry Accepted for 1.5 seconds, returns to the control method display. 5 5.5 SETTING OPERATION CONDITIONS PROGRAMMING MODE The constants of the VS−616G5 are composed of group symbols, function Nos. and serial Nos. for or key to change the group, function or name each function item as shown below. Use display and select one by [DATA/ENTER] key. For details of the constants, refer to Table A−4 ”Constants List” or Descriptive Manual for Constants. Constant No. b 1 − 01 Serial No. for each function item b : Application−related constants Function No. d : Frequency reference−related constants C : Accel/decel time setting constants E : Motor−related constants Group symbol F : Option−related constants H : Control circuit terminal−related constants L : Protection−related constants o : Operator−related constants Constants to be set/read by digital operator can be selected by setting the access level (constant A1−01) as described below. Table 22 Constant Access Level A1−01 Name 0 Exclusive for monitoring Description Constants can be set/read in operation mode or initialize mode. Constants cannot be set/read in programming mode or modified constants mode. ⋅Up to 32 constants to be set/read by digital operator can be selected. ⋅When A1−01=01 is selected, constants specified by A2−01 to 32 can be set/read by digital operator. Set the constant numbers in A2−01 to 32. ⋅When constant numbers are not set in A2−01 to 32, user selected constants by A1−01 cannot be set/read. 1 User selected constants 2 QUICK−START Constants required for quick−start operation are set/read. For details, refer to Descriptive Manual for Constants. 3 BASIC Constants required for basic operation are set/read. For details, refer to Descriptive Manual for Constants. 4 ADVANCED Constants required for advanced operation are set/read. For details, refer to Descriptive Manual for Constants. 53 ( Example 1 ) Select QUICK−START and change the decel time 1 (C1−02) from 10.0 to 20.0 seconds while frequency reference is displayed. Table 23 Description Changing Constant Data when QUICK−START is Selected Key Sequence ⋅Displaying frequency reference. ⋅Displays Operation. ** Main Menu ** Operation MENU ** Main Menu ** Programming Reference Source Terminal DATA ENTER ⋅Change the constant name display. (Displays Decel Time 1.) ⋅Depress DATA/ENTER key. The value to be set blinks. Decel Time 1 0010.0 Sec DATA ENTER RESET 54 Decel Time 1 0020.0 Sec DATA ENTER Entry Accepted MENU ** Main Menu ** Operation DATA ENTER Frequency Ref U1−01 = 60.00 HZ ⋅Return to Operation. ⋅Select Operation to display frequency reference. When selecting Programming, the constant name and setting are displayed. Decel Time 1 C1−02 = 10.0 Sec ⋅Change the value to 20.0 seconds. ⋅Write−in the constant. Remarks Frequency Ref U1−01 = 60.00 HZ ⋅Displays Programming. ⋅Select Programming. Digital Operator Display After displaying Entry Accepted for 1.5 seconds, returns to the decel time 1 display. 5 SETTING OPERATION CONDITIONS ( Example 2 ) Select BASIC and change the decel time 1 (C1−02) from 10.0 to 20.0 seconds while frequency reference is displayed. Table 24 Description Changing Constant Data when BASIC is Selected Key Sequence ⋅Displaying frequency reference. ⋅Displays Operation. ** Main Menu ** Operation MENU ** Main Menu ** Programming DATA ENTER ⋅Change the function display. (Displays Accel/Decel.) ⋅Select the function (accel/decel time). Function C1 Accel/Decel Searches for C1. DATA ENTER ⋅Return to Operation. MENU DATA ENTER Displays C1−02. Decel Time 1 0010.0 Sec DATA ENTER RESET ⋅Select Operation to display frequency reference. When selecting Programmig, Function b1 is displayed. Decel Time 1 C1−02 = 10.0 Sec ⋅Change the value to 20.0 seconds. ⋅Write−in the constant. Function b1 Sequence Accel Time 1 C1−01 = 10.0 Sec DATA ENTER ⋅Change the name display. (Displays Decel Time 1.) ⋅Depress DATA/ENTER key. The value to be set blinks. Remarks Frequency Ref U1−01 = 60.00 HZ ⋅Displays Programming. ⋅Select Programming. Digital Operator Display Decel Time 1 0020.0 Sec Entry Accepted After displaying Entry Accepted for 1.5 seconds, returns to decel time display. ** Main Menu ** Operation Frequency Ref U1−01 = 60.00 HZ 55 ( Example 3 ) Select ADVANCED and change the decel time 1 (C1−02) from 10.0 to 20.0 seconds while frequency reference is displayed. Table 25 Description Changing Constant Data when ADVANCED is Selected Key Sequence ⋅Displaying frequency reference. ⋅Displays Operation. ** Main Menu ** Operation MENU ** Main Menu ** Programming Group b Application DATA ENTER ⋅Change the group name. (Displays Tuning.) ⋅Select the group. (Selects Tuning group.) ⋅Select the function. (Selects accel/decel time.) DATA ENTER Function C1 Accel/Decel DATA ENTER Accel Time 1 C1−01 = 10.0 Sec Decel Time 1 C1−02 = 10.0 Sec DATA ENTER RESET DATA ENTER Entry Accepted MENU ** Main Menu ** Operation 56 DATA ENTER When selecting the function, the constant name is displayed. Displays C1−02. Decel Time 1 0020.0 Sec ⋅Write−in the constant. ⋅Return to Operation. (Displays Operation.) When selecting the group, the function menu is displayed. Select a function name using ∧ or ∨ key if necessary. Decel Time 1 0010.0 Sec ⋅Change the value to 20.0 seconds. ⋅Select Operation to display frequency reference. When selecting the programming mode, the group menu is displayed. Group C Tuning ⋅Change the constant name. (Displays Decel Time 1.) ⋅Depress DATA/ENTER key. The value to be set blinks. Remarks Frequency Ref U1−01 = 60.00 HZ ⋅Displays Programming. ⋅Select Programming. Digital Operator Display Frequency Ref U1−01 = 60.00 HZ After displaying Entry Accepted for 1.5 seconds, returns to decel time 1 display. 5 5.6 SETTING OPERATION CONDITIONS MODIFIED CONSTANTS MODE Compares the constant values preset at the factory with the values changed by the user, and displays the constants changed from the preset constants automatically. In the modified constants mode, constants can be read; in addition, they can also be set or changed. ( Example ) Read the constants C1−01 (accel time 1) and E1−01 (input voltage) when the factory settings have been changed. In addition, change the setting of E1−01 (input voltage) from 575V to 600V in this mode. Table 26 Description Typical Operation in Modified Constants Mode Key Sequence ⋅Displaying frequency reference. ⋅Displays Operation. ** Main Menu ** Operation MENU ** Main Menu ** Modified Consts Accel Time 1 C1−01 = 20.0 Sec DATA ENTER ⋅Displays the next−to−be−changed constant. (Displays input voltage.) ⋅Depress DATA/ENTER key. The value to be set blinks. ⋅Select Operation to display frequency reference. Input Voltage 575 VAC DATA ENTER RESET DATA ENTER ⋅Displays the next−to−be−changed constant. ⋅Returns to Main Menu. (Displays Operation.) When selecting Modified Consts the constants which have been changed from factory settings are displayed. Input Voltage E1−01 = 575 VAC ⋅Change the value to 600V. ⋅Write−in the constant. Remarks Frequency Ref U1−01 = 60.00 HZ ⋅Displays Modified Consts. ⋅Select the Modified Consts. Digital Operator Display Input Voltage 600 VAC Entry Accepted After displaying Entry Accepted for 1.5 seconds, returns to input voltage display. Accel Time 1 C1−01 = 20.0 Sec MENU DATA ENTER ** Main Menu ** Operation Frequency Ref U1−01 = 60.00 HZ 57 5.7 MEMOBUS CONTROL VS−616G5 can perform serial transmission by using a programmable controller (PLC) and MEMOBUS communication. MEMOBUS is composed of one master PLC and 1 to 31 (maximum) slave units (VS−616G5). The master performs signal transmission with one slave at one time. Therefore, address numbers are assigned to each slave in advance and the master specifies a number to perform signal transmission. The slave which receives the command from the master executes the function and response to the master. (1) Communication Specification S Communication with PLC in accordance with MEMOBUS specifications is enabled only in RTU mode. S RS−422 or RS−485 transmission is selectable by SW2. S Transmission method : Asynchronous, half−duplex transmission S Transmission parameter : S Baud rate: Selectable from 1200, 2400, 4800, 9600 BPS by setting constant H5−02. S Data length:Fixed to 8 bits S Parity: Parity/no−parity, even/odd parity selectabe by setting constant H5−03 S Stop bit: Fixed to 1 bit S Maximum number of units to be connected : 31 units (when RS−485 is used) S Self−diagnosis function of transmission part provided (2) Data to be Sent/Received by Communication Data to be sent/received by communication are run commands, frequency reference, fault constants, inverter status and constant setting/reading. (a) Operation Mode Selection (b1−01, b1−02) Select the run command and frequency reference input method in constants b1−01 and b1−02. To provide a run command and frequency reference by communication, set these constants to “2”. Also, without regard to this selection, monitoring of running status, constant setting/reading, fault reset and multi−function input command from the PLC are enabled. The multi−function input command becomes OR with the command input from control circuit terminals 3 to 8. 58 5 SETTING OPERATION CONDITIONS (b) MEMOBUS Frequency Reference Unit (o1−03, o1−04) Enabled when bit 0 of register No. 0F is “1”. The frequency reference units, the frequency reference and output frequency monitors from master are indicated. The unit is 0.01 Hz when bit 0 of register No. 0 is “0”. (c) MEMOBUS Slave Address (H5−01) The slave address number is set. Set another slave address number connected on the same transmission line. SW2 E ª Fig. 18 SW1 485 OFF 422 2 1 11 35 36 13 14 15 16 17 33 25 27 26 1 2 3 4 5 6 7 8 21 22 23 37 42 43 40 41 E ª 18 19 20 9 10 Arrangement of Control Circuit Terminals, SW1 and SW2 (3) Functions of SW1 and SW2 (a) SW1 (for terminating resistor) Provide a terminating resistor to each receiver side when transmission is perfomed by RS−422A (four−wire system) between one master and one slave. Provide a terminating resistor in devices (both ends) connected to the communication cable when transmission is performed by RS−485 (two−wire system) between one master and more than one slave. The VS−616G5 is provided with a built−in terminating resistor. Switch the resistor ON/ OFF by SW1. Table 27 Functions of SW1 Communication Cable Connecting Method SW1 Setting Four−wire system (1 to 1) Switch both 1 and 2 to the ON side (numbering side). Two−wire system (1 to n) Switch 1 to the OFF side and 2 to the ON side only for devices (both ends) connected to the communication cable. For other devices, switch both 1 and 2 to the OFF side. (b) SW2 Table 28 Functions of SW2 Transmission Method SW2 Setting RS−422A (four−wire system) To 422 side RS−485 (two−wire system) To 485 side 59 6 MAINTENANCE AND INSPECTION WARNING S Never touch high−voltage terminals in the inverter. Failure to observe this warning can result in an electrical shock. S Replace all protective covers before powering up the inverter. To remove the cover, make sure to disconnect supply mains. Failure to observe this warning can result in an electrical shock. S Perform maintenance or inspection only after verifying that the CHARGE LED goes OFF, after the main circuit power supply is turned OFF. The capacitors are still charged and can be dangerous. S Only authorized personnel should be permitted to perform maintenance, inspections or parts replacement. [Remove all metal objects (watches, bracelets, etc.) before operation.] (Use tools which are insulated against electrical shock.) Failure to observe this warning can result in an electrical shock. CAUTION S The control PC board employs CMOS ICs. Do not touch the CMOS elements. They are easily damaged by static electricity. S Do not connect or disconnect wires or connectors while power is applied to the circuit. Failure to observe this caution can result in personal injury. S When removing the wiring, remove the ground wire last. This chapter describes basic maintenance and inspection procedures for the VS−616G5. 60 6 6.1 MAINTENANCE AND INSPECTION PERIODIC INSPECTION The VS−616G5 will function longer if it is kept clean, cool and dry, while observing the precautions listed in Par. 2.3. Check for tightness of electrical connections, discoloration or other signs of overheating or aging. Use Table 29 as your inspection guide. Before servicing, turn OFF AC main circuit power and be sure that the CHARGE LED is OFF. Table 29 Periodic Inspection Component Check External Terminals, Unit Mounting Bolts Bolts, Connectors, etc. Heatsink Printed Circuit Board Loose screws Tighten. Loose connectors Tighten. Build−up of dust and dirt Blow with dry compressed air of 39.2¢104 to 58.8¢104 Pa (4 to 6 kg¡cm2) pressure. Accumulation of conductive dust or oil. Blow with dry compressed air of 39.2¢104 to 58.8¢104 Pa (4 to 6 kg¡cm2) pressure. If dust and oil cannot be removed, replace the board. For abnormal noise and vibration. Whether the cumulative operation time Replace the cooling fan. exceeds 20,000 hours or not. Cooling Fan Power Elements Smoothing Capacitor 6.2 Corrective Action Accumulation of dust and dirt Blow with dry compressed air of 39.2¢104 to 58.8¢104 Pa (4 to 6 kg¡cm2) pressure. Discoloration or odor Replace the capacitor or inverter unit. PARTS REPLACEMENT SCHEDULE (GUIDELINES) Replace the following parts periodically, for a long, safe, trouble free working life of VS−616G5. NOTE Table 30 Parts Replacement Schedule Parts Interval (Approx.) Cooling Fan 2 to 3 years Smoothing Capacitor 5 years Remarks Replace with new one. Replace with new one. (Decided after inspection.) Breakers or Relays Decided after inspection. inspection Fuse 10 years Replace with new one. Aluminum Electrolytic Capacitor on PC Board 5 years Replace with new one. (Decided after inspection.) Operating conditions are as follows: Ambient temperature : 30_C yearly average Load factor : 80% or below Operation rate : 12 hours or below /day 61 7 TROUBLESHOOTING This chapter describes the inverter fault display and the fault contents caused by motor / machine malfunctions and the corrective actions to be taken. 7.1 FAULT DIAGNOSIS AND CORRECTIVE ACTIONS (1) When the VS−616G5 detects a fault, the fault is displayed on the digital operator and activates the fault contact output and the motor coasts to a stop. Check the cause in the table below and take the corrective actions. (2) If the inspections or corrective actions described cannot solve the problem, contact your YASKAWA representative immediately. (3) To restart, turn ON the reset input signal or depress [>RESET] key or shut OFF the main circuit power supply once, to reset the stop status. 62 7 Table 31 Fault Display TROUBLESHOOTING Fault Diagnosis and Corrective Actions Description Details Corrective Action Rank* (Standard Value) Main circuit undervoltage (PUV) Undervoltage in the direct current main circuit during running. Detection level 400 V class: Approx. 380 V or less UV Under Voltage Momentary power loss ⋅The main circuit direct current voltage fell below the PUV level. ⋅The control power source fell below the CUV level. ⋅The pre−charge contactor opened. OC Overcurrent Overcurrent (OC) ⋅Check the motor coil resistance. The inverter output current exceeded the ⋅Extend the accel/decel time. ⋅Check the motor insulation. OC level. ⋅Multi-meter check A GF Ground Fault Grounding (GF) (Earth fault) Inverter output grounding current exceeded 50% of inverter rated current. ⋅Check that motor insulation has not deteriorated. ⋅Check that connection between inverter and motor is not damaged. A OV DC Bus Overvolt Overvoltage (OV) The main circuit direct current voltage exceeded the OV level. Extend the deceleration time, add Detection level braking circuit. 400 V class: Approx. 800 V A Load short−circuit (SC) Inverter output (load) is short−circuited. ⋅Check the motor coil resistance. ⋅Check the motor insulation. A PUF DC Bus Fuse Open Fuse blown (FU) ⋅The direct current circuit fuse is blown. ⋅The output transistors were damaged. Check for damaged transistor, load side short circuit, grounding, etc. A OH1 Heatsnk MAX tmp Heatsink overheat (OH1) The transistor heatsink temperature exceeded the allowable value. Check the fan and ambient temperature. A OL1 Motor Overloaded Motor overload (OL1) Inverter output exceeded the motor overload level. Reduce the load. A OL2 Inv Overloaded Inverter overload (OL2) Inverter output exceeded the inverter overload level. Reduce the load, extend the acceleration time. A Overtorque detection 1 When torque detection selection 1 is enabled (L6−01=1 to 4), inverter output current (in V/f control) or inverter torque reference (in vector control) exceeded torque detection level 1 (L6−02) for the time set by torque detection time 1 (L6−03) or longer. UV1 DC Bus Undervolt SC Short Circuit OL3 OL4 Overtorque detection 2 When torque detection selection 2 is enabled (L6−01=1 to 4), inverter output current (in V/f control) or inverter torque reference (in vector control) exceeded torque detection level 2 (L6−05) for the time set by torque detection time 2 (L6−06) or longer. ⋅Check the power supply wiring. ⋅Correct the line voltage. A B A (when L6−01 =3 or 4) B (when L6−01 =1 or 2) A (when L6−04 =3 or 4) B (when L6−04 =1 or 2) 63 Table 31 Details Corrective Action Rank* (Standard Value) Fault Display Description PF Input Pha Loss Input open−phase ⋅Inverter input power supply has open− ⋅Check the line voltage. phase. ⋅Re−tighten the input terminal ⋅Large unbalance in input voltage. screws. A LF Output Pha Loss Output open−phase Inverter output has open−phase. ⋅Check the output wiring. ⋅Check the motor impedance. ⋅Re−tighten the output terminal screws. A RR Dyn Brk Transistr Braking transistor failure The braking transistor has failed. Replace the inverter. A RH Dyn Brk Resistor Braking resistor unit overheat The braking resistor unit temperature has exceeded the allowable value. Reduce the regenerative load. (Protects only inverter built−in type) A OS Overspeed Det Overspeed (OS) The motor speed exceeded the overspeed level. A PGO PG open PG open circuit (PGO) The PG line is broken. ⋅Check the PG line. ⋅Check the condition of the motor lock or the load. A DEV Speed Deviation Speed deviation (DEV) The deviation of the speed reference and speed feedback exceeded the regulation Check the load. level. B OPR Oper Disconnect Digital operator connection fault The digital operator was disconnected during operation by run command from the digital operator. Check the operator connection. A ERR EEPROM R/W Err EEPROM writing fault (ERR) EEPROM internal data did not match when initializing the constant. Replace the control card. A CALL Serial Com Call Control data was not received normally SI−B transmission error when power supply is turned ON. Check transmission devices and transmission signals. C CE Memobus Com Err Transmission error Control data was not received normally when power supply is turned ON. Check transmission devices and transmission signals. A Control fault In open loop vector control, it took 3 seconds or more for torque limit during deceleration to stop. Check the motor−related constants. A SVE Zero Servo Fault Zero−servo fault The rotation position deviated by 10000 r/min or more during zero−servo operation. ⋅Check that the torque limit value is not too low. ⋅Check that the load torque is not excessive. ⋅Check the noise of PG signals. A EF External Fault Operation reference fault (External) Both FWD and REV run commands were Check sequence circuit. closed for 500 ms or more. EF3 External Fault 3 External fault at terminal 3 EF4 External Fault 4 External fault at terminal 4 EF5 External Fault 5 External fault at terminal 5 EF6 External Fault 6 External fault at terminal 6 CF Out of Control 64 Fault Diagnosis and Corrective Actions (Cont’d) B A Check the condition of the input terminal. Fault occurred in the external control If the fault is displayed when circuit. terminal is not connected, replace the inverter. B B B 7 Table 31 Fault Display Fault Diagnosis and Corrective Actions (Cont’d) Description EF7 External Fault 7 External fault at terminal 7 EF8 External Fault 8 TROUBLESHOOTING Details Corrective Action Rank* (Standard Value) B External fault at terminal 8 Check the condition of the input terminal. Fault occurred in the external control If the fault is displayed when circuit. terminal is not connected, replace the inverter. OPE01 kVA Selection kVA selection fault (OPE01) kVA selection fault Check and set the constant data. C OPE02 Limit Constant setting range fault (OPE02) Constant data is out of range. Check the constant data settings. C Multi−function contact input selection fault (OPE03) ⋅In H1−01 to H1−06 settings: ⋅The same values are set except for F, FF and 20 to 2F. ⋅Both UP/DOWN and HOLD commands are set. ⋅UP and DOWN commands are not set at the same time. ⋅Two or more HOLD, UP/DOWN, sample/hold commands are set. ⋅Two or more speed search 1, 2, 3 commands are set. ⋅In B5−01 setting, both PID control and UP/DOWN commands are set. ⋅In H3−09 setting, terminal 13/14 selection and the value other than ”Not used” are set at the same time. Check the constants. C OPE05 Sequence Select Option reference selection fault (OPE05) ⋅In B1−01 setting, C−option is not connected although frequency reference from C−option is selected. ⋅In B1−02 setting, C−option is not connected although run command from C−option is selected. Check the constants. C OPE06 PG Opt Missing Control method selection fault (OPE06) In A1−02 setting: ⋅PG is not connected although V/f control with PG feedback is selected. ⋅PG−B is not connected although flux vector control is selected. Check the constants. C OPE07 Analog Selection Multi−function analog input selection fault (OPE07) ⋅In H3−05 and H3−09 settings, the same values are set except for 0 and 1F. ⋅While AI−14B is connected, ”0” is set in F2−01 and option/inverter selection is set in multi−function contact input. Check the constants. C Check the constants. C OPE03 Terminal B When the settings of E1−04 to E1−10 do not satisfy the following conditions: F Max.≧F A > F B ≧ F Min. (E1−04)(E1−06)(E1−07)(E1−09) V OPE10 V/f Ptrn Setting V/f data setting fault (E1−04 to E1−10) VMax (E1−05) VC (E1−08) VMin (E1−10) 0 FMin (E1−09) FB (E1−07) FA FMax (E1−06) (E1−04) F 65 Table 31 Fault Display Fault Diagnosis and Corrective Actions (Cont’d) Corrective Action Details OPE11 Carr Frq/On−Delay Constant setting fault When one of the following setting fault occurs: ⋅Carrier frequency upper limit (C6−01) >5kHz, and Carrier frequency lower limit (C6−02)≦5kHz ⋅Carrier frequency proportional gain (C6−03)>6 and (C6−01)<(C6−02) ⋅Setting error of upper/lower limit of C6−01 to 03 and C8−15. Check the constants. C CPF00 COM−ERR(OP&INV) Control circuit fault 1 (CPF00) (Digital operator transmission fault) ⋅Transmission between the inverter and digital operator cannot be established 5 seconds after supplying power. ⋅MPU peripheral element check fault (initial) ⋅Insert the digital operator connector again. ⋅Check the control circuit wiring. ⋅Replace the control card. A CPF01 COM−ERR(OP&INV) Control circuit fault 2 (CPF01) (Digital operator transmission fault) ⋅Transmission between the inverter and digital operator is established once after supplying power, but later transmission fault continues for more than 2 seconds. ⋅MPU peripheral element check fault (online) ⋅Insert the digital operator connector again. ⋅Check the control circuit wiring. ⋅Replace the control card. A CPF02 BB Circuit Err Baseblock circuit fault (CPF02) CPF03 EEPROM Error EEPROM fault (CPF03) A A Inverter control unit fault. fault Replace the control card. card CPF04 Internal A/D Err CPU internal A/D converter fault (CPF04) CPF05 External A/D Err CPU external A/D converter fault (CPF05) CPF06 Option Error Option connection fault (CPF06) The option card is not installed correctly. Install the option card again. A CPF20 Option A/D Error A/D converter fault in analog speed reference card (CPF20) Option card (AI−14B) A/D converter fault Replace the option card. A A A * The ranks are classified as follows: Rank A : Major fault (Motor coasts to a stop, operator indication lights, and fault contact is output.) Rank B : Fault [Operation continues, operator indication blinks, no fault contact is output, and minor fault contact is output (when multi−function output is selected). Rank C : Warning (Operation cannot be performed, operator indication lights, no fault contact is output, no minor fault contact is output.) 66 Rank* (Standard Value) Description 7 7.2 TROUBLESHOOTING MOTOR FAULTS AND CORRECTIVE ACTIONS (1) If any of the following faults occurs in the motor, check the cause and provide the relevant corrective action. (2) If these inspections and corrective actions cannot solve the problem, contact your YASKAWA representative immediately. Table 32 Motor Faults and Corrective Actions Fault Check Point Corrective Action ⋅Turn ON power supply. Power supply voltage applied to power supply ⋅Turn OFF power supply, and then ON again. terminals L1, L2, L3 ? CHARGE LED is ON ? ⋅Check power supply voltage. ⋅Make sure terminal screws are tight. Use rectifier type voltmeter to test. Voltage output to output terminals U(T1), V(T2), W(T3) Turn OFF power supply, then turn ON again. correct? Motor does not rotate. Motor locks due to excessive load? Reduce the load and release the lock. Fault displayed in operator display? Check troubleshooting table. FWD or REV run command entered? Check the wiring. Frequency setting voltage entered? ⋅Correct the wiring. ⋅Check frequency setting voltage. Reference selection (b1−01), operation method Input the correct set value. selection (b1−02) correct? Motor rotation reverses reverses. Motor rotates, bbut M variable speed not available. Wiring of terminals U(T1), V(T2), W(T3) Match wiring to the phase order of the motor correct? leads U(T1), V(T2), W(T3) . FWD and REV wiring run signals entered? Correct the wiring. Wiring of frequency setting circuit correct? Correct the wiring. Reference selection (b1−01), operation method With the digital operator, check the reference selection (b1−02) correct? selection or operation method selection. Load excessively large? Reduce the load. Motor ratings (number of poles, voltage) Check motor nameplate specifications. correct? Motor r/min too high or too low. low Accel/decel speed change ratio for gears, etc. Check speed changer (gears, etc.) correct? Maximum frequency set value correct? Check the maximum frequency set value. Use rectifier voltmeter. Voltage between motor Check V/f characteristics values. terminals not excessively reduced? Motor r/min not stable during operation. Load excessively large? Reduce the load. Load variation excessively large? ⋅Reduce the load variation. ⋅Increase inverter motor capacity. 3−phase or single−phase power supply used? For 3−phase power supply, open phase? ⋅For 3−phase power supply, check the wiring if power supply is open phase. ⋅For single−phase power supply, connect AC reactor to the power supply. 67 APPENDIX 1 SPECIFICATIONS Specifications Model CIMR−G5C 51P5 52P2 53P7 55P5 57P5 5011 5015 Max. Applicable Motor Output * kW 1.5 2.2 3.7 5.5 7.5 11 15 Constant Torque 3.5 4.1 6.3 9.8 12.5 17 22 Variable Torque 3.9 4.6 7 11 14 19 25 Powe wer Sup pply Outp utput Characteris Ch istics Table A−1 Rated Output Current (A) 3−Phase 500/525/575/600 V (Proportional to input voltage) Max. Output Voltage Rated Output Frequency Up to 400 Hz available by programming Rated Input Voltage and Frequency 3−Phase 500/525/575/600 V 50/60 Hz +10%, −15% Allowable Voltage Fluctuation Allowable Frequency Fluctuation ¦5% Sine wave PWM Control Method 150% / 1 Hz (150% / 0 r / min with PG)[ Starting Torque Speed Control Range 1:100 (1:1000 with PG)[ Speed Control Accuracy ¦0.2% (¦ 0.02% with PG)[ 5 Hz (30 Hz with PG)[ Speed Response Available (4 quadrants can be changed by parameter setting.) Torque Limit Co ontrol C Charact cteristics cs Torque Accuracy ¦5% 0.1 to 400 Hz Frequency Control Range Digital command : ¦0.01% (−10°C to +40°C) Frequency Accuracy Analog command : ¦0.1% (25°C ¦ 10°C) Digital operator reference : ¦0.01 Hz Frequency Resolution Analog reference : ¦0.03 Hz/60 Hz (11 bit + code) 0.001 Hz Output Frequency Resolution 150% of rated output current for 1 minute Overload Capacity −10 to 10 V, 0 to 10 V, 4 to 20 mA Frequency Setting Signal Accel/Decel Time 0.01 to 6000.0 sec (Accel/decel time setting independently, 4 steps available) Braking Torque Approx. 20% (Cont’d) * Based on a YASKAWA standard 4−pole motor for max. applicable motor output. [ 68 Occasional tuning may be required. APPENDIX 1 SPECIFICATIONS Table A−1 Specifications (Cont’d) Model CIMR−G5C En Environm nment P Protective ve Funct ctions Motor Overload Protection 51P5 52P2 53P7 55P5 57P5 5011 Protected by electronic thermal overload relay Instantaneous Overcurrent Motor coasts to a stop at approx. 200% of inverter rated current. Blown Fuse Protection Motor coasts to a stop by blown−fuse. Overload Motor coasts to a stop after 1 minute at 150% of rated output current. Overvoltage Motor coasts to a stop if converter output voltage exceeds 1040 V. Undervoltage Motor coasts to a stop if converter output voltage drops to 490 V or below. Momentary Power Loss Immediately stop by 15 ms and above momentary power loss. (Factory setting) Continuous operation during power loss less than 2 sec is equipped as standard. Heatsink Overheat Protected by thermistor Stall Prevention Stall prevention during accel/decel and constant speed operation Ground Fault Protected by electronic circuit (Overcurrent level) Power Charge Indication Charge LED stays ON until bus voltage drops below 50 V. Ambient Temperature −10°C to +40°C (Enclosed wall−mounted type) −10°C to +45°C (Open chassis type) Humidity 90%RH or less Storage Temperature −20°C to +60°C Location Indoor (protected from corrosive gases and dust) Elevation 1000 m or less Vibration 9.81 m/s2 (1G) at 10 to less than 20 Hz, up to 1.96 m / s2 (0.2G) at 20 to 50 Hz Applicable Standards 5015 prEN50178 EN50082−2 EN50081−2 (with RFI filter, screened cable) 69 APPENDIX 2 DIMENSIONS (mm) H H2 H1 The figures below show a 575V 1.5 kW model. Use open chassis type 15 kW or less with the top and bottom covers removed. W1 4−d W D Fig. A−1 Dimensions of VS−616G5 Table A−2 V lt Voltage VS−616G5 Dimensions (mm) and Approx. Mass (kg) Motor Capacity kW 1.5 2.2 Open Chassis Type (IP00) W H D W1 H1 H2 Mass (kg) W H D W1 H1 H2 Mass (kg) d* 140 280 180 126 266 70 7.0 4 140 280 180 126 266 70 7.0 4 M5 200 300 205 186 285 8.0 200 300 205 186 285 8.0 250 380 225 236 365 75 7.5 250 380 225 236 365 75 7.5 3.7 575V Class 5.5 6 7.5 11 15 Enclosed Wall−mounted Type (NEMA1) 65 6.5 13 6 * Mounting holes are the same for the open chassis type and the enclosed wall−mounted type. 70 65 6.5 13 M6 M6 APPENDIX 3 APPENDIX 3 3.1 TYPICAL CONNECTION DIAGRAM TYPICAL CONNECTION DIAGRAM BRAKING RESISTOR UNIT For Models CIMR−G5C51P5 to −G5C5015 (575 V Class 1.5 to 15 kW) Overload Relay Trip Contact Use sequencer to break power supply side on overload relay trip contact of braking resistor unit. Fuse Line Filter MC OFF ¨1 L1 (R) Braking Resistor Unit [ B ¨2 © B1 B2 U (T1) Motor L2 (S) V (T2) L3 (T) W (T3) IM VS−616G5 MC MC Overload Relay Trip Contact of Braking Resistor Unit 1 2 Short−circuit Bar 250 VAC or less THRX x P L1 3−Phase Power Supply 500 to 600 V L2 50/60 Hz L3 ON 1 DC Reactor (Option) * 2 SA THRX 23 SA MC Analog Monitor 2 TRX + AM SA − TRX 20 18 Fault Contact 21 Analog Monitor 1 1 Forward Run when CLOSED 2 Reverse Run when CLOSED Forward Run/Stop Reverse Run/Stop Factory Setting External Fault 3 Fault Reset 4 Multi−step Speed Setting 1 (Master/Aux Change) 5 Multi−step Speed Setting 2 6 Jog Reference 7 External Baseblock 8 22 19 20 9 10 11 35 36 Shield Sheath Connection Terminal 2 kΩ 2 kΩ Master Frequency Reference 0 to +10 V 4 to 20 mA 0 to +10 V 0V Freq. Setting Power Supply +15V 20 mA 13 Master Freq. Ref. 0 to 10V (20kΩ) P 14 Master Freq. Ref. 4 to 20 mA (250Ω) P P 18 Fault Contact Output 250 VAC 1 A or less 30 VDC 1 A or less 20 Multi−function Contact Output 250 VAC 1 A or less 30 VDC 1A or less (Signal during Running at Factory Setting) +24V E 15 Multi−function Analog Output −10 to +10 V 2 mA (Output Frequency at Factory Setting) − FM + E 18 Multi−function Contact Input Multi−function Analog Output −10 to +10V 2 mA (Output Current at Factory Setting) 25 27 26 37 Opto−coupler output 1 (Zero Speed Signal at Factory Setting) Opto−coupler Output 2 (Speed Agree Signal at Factory Setting) Multi−function Open Collector Output 48 V 50 mA or less 16 Multi−function Analog Input 0 to 10V (20kΩ) 17 (Aux Freq. Ref. at Factory Setting) 0V 33 Freq. Setting Power Supply −15V 20 mA * When installing a DC reactor (option), remove the common bar between ¨1 and ¨2 terminals (provided as standard) and connect a DC reactor with the terminals. [ When using the braking resistor unit, set constant L3−04 to “0” (stall prevention selection during decel is disabled). If it is not changed, the inverter may not stop within set decel time. 71 3.2 VS OPERATOR MODELS JVOP−95 AND JVOP−96 Line Filter Fuse MCCB Short−circuit Bar (Provided as Standard) ¨1 L1 3−Phase L2 Power Supply L3 ¨2 © B1 L1(R) B2 U (T1) L2(S) VS−616G5 L3(T) Motor V (T2) IM W (T3) PE VS Operator Models JVOP−95, −96 FWD RUN STOP REV RUN 1 1 Forward Run when CLOSED 2 Reverse Run when CLOSED 3 2 RESET 4 AUX MASTER 4 5 5 6 Multi−function Contact Input 7 8 11 11 35 36 E 15 FREQ SET P 14 Master Freq. Ref. 4 to 20 mA (250Ω) 16 Multi−function Analog Input 0 to 10V (20kΩ) 17 17 33 SOURCE 9 9 RUN 10 10 FAULT 18 P 20 FM F1 Freq. Setting Power Supply −15V 20 mA Multi−function Contact E Output (Signal during Running at Factory Setting) 25 Fault Contact Output 23 Multi−function Analog Output 21 Multi−function Analog Output (Output Frequency at Factory Setting) P F3 0V 18 19 FREQ. METER Shield Sheath Connection Terminal 15 Freq. Setting Power Supply +15V 20 mA 13 Master Freq. Ref. 0 to 10V (20kΩ) 13 P MTR CAL +24V 27 26 37 Opto−coupler Output 1 (Zero Speed Signal at Factory Setting) Opto−coupler Output 2 (Speed Agree Signal at Factory Setting) Multi−function Open Collector Output 48 V 50 mA or less 22 E Note: Main circuit terminals are indicated by 15 kW model or below. 72 APPENDIX 3 3.3 TYPICAL CONNECTION DIAGRAM SEQUENCE INPUT AND OUTPUT CONNECTION WITH NPN TRANSISTOR (0V COMMON) VS−616G5 1 Forward Run/Stop 2 Reverse Run/Stop 3 External Fault 4 Fault Reset Factory Setting 5 Multi−step Speed Setting 1 (Master/Aux Change) 6 Multi−step Speed Setting 2 7 Jog Reference 8 External Baseblock 11 35 36 +24V E Surge Suppressor 250 VAC Max 18 Fault Contact Output 250VAC 1A or less 30 VDC 1A or less 19 20 30 VDC Max 9 48 VDC Max Multi−function Contact Output 250 VAC 1A or less 30 VDC 1A or less (Signal during Running at Factory Setting) 10 25 48 VDC Max Opto−coupler Output 48V 50mA or less (Zero−speed Signal at Factory Setting) 27 26 Opto−coupler Output 48V 50 mA or less (Speed Agree Signal at Factory Setting) 37 73 3.4 SEQUENCE INPUT AND OUTPUT CONNECTION WITH PNP TRANSISTOR (SUPPLY SIDE COMMON) VS−616G5 Factory Setting Forward Run/Stop 1 Reverse Run/Stop 2 External Fault 3 Fault Reset 4 Multi−step Speed Setting 1 (Master/Aux Change) 5 Multi−step Speed Setting 2 6 Jog Reference 7 External Baseblock 8 11 35 36 E 18 Fault Contact Output 250 VAC 1A or less 30 VDC 1A or less 250 VAC Max 19 20 Surge Suppressor 30 VDC Max 48 VDC Max 48 VDC Max 74 9 Multi−function Contact Output 250 VAC 1A or less 30 VDC 1A or less (Signal during Running at Factory Setting) 10 25 Opto−coupler Output 48V 50 mA or less (Zero−speed Signal at Factory Setting) 27 26 Opto−coupler Output 48V 50 mA or less (Speed Agree Signal at Factory Setting) 37 +24V APPENDIX 4 APPENDIX 4 CONSTANTS LIST Table A−3 Digital Operator Function Display Monitor Constants List Digital Operator Display Con Constant No. Frequency Ref U1−01 Output Freq Monitor CONSTANTS LIST U1−02 Control Method: (f=Monitor enable, ×=Monitor disable) Constant Name Unit V/f control V/f with Open Flux PG Loop Feed- Vector Vector back Frequency reference 0.01 Hz[ f f f f Output frequency 0.01 Hz[ f f f f f f f f f f f f Output Current U1−03 Output current 0.1A] Control Method U1−04 Control method Motor Speed U1−05 Motor speed 0.01 Hz[ × f f f Output Voltage U1−06 Output voltage 0.1V f f f f DC Bus Voltage U1−07 DC bus voltage 1V f f f f Output kWatts U1−08 Output power 0.1 kW f f f f Torque Reference U1−09 Torque reference (internal) 0.1% × × f f Input Term Sts U1−10 Input terminal status f f f f Output Term Sts U1−11 Output terminal status f f f f Int Ctl Sts 1 U1−12 Internal control status f f f f Elapsed Time U1−13 Cumulative operation time 1H f f f f FLASH ID U1−14 Software No. (at FLASH side) f f f f Term 13 level U1−15 Control circuit terminal 13 input voltage 0.1% f f f f Term 14 level U1−16 Control circuit terminal 14 input voltage 0.1% f f f f Term 16 level U1−17 Control circuit terminal 16 input voltage 0.1% f f f f Mot SEC Current U1−18 Motor secondary current (Iq) 0.1% f f f f Mot EXC Current U1−19 Motor exciting current (Id) 0.1% × × f f SFS Output U1−20 Output frequency after soft−start 0.01 Hz[ f f f f ASR Input U1−21 ASR input 0.01% × f × f ASR Output U1−22 ASR output 0.01% × f × f Speed Deviation U1−23 Speed deviation 0.01% × f × f PID Feedback U1−24 PID feedback amount 0.01% f f f f DI−16 Reference U1−25 DI−16H input status f f f f Voltage Ref (Vq) U1−26 Output voltage reference Vq 0.1V × × f f Voltage Ref (Vd) U1−27 Output voltage reference Vd 0.1V × × f f CPU ID U1−28 Software No. (at CPU side) f f f f ACR(q) Output U1−32 ACR q−axis output 0.1% × × f f ACR(d) Output U1−33 ACR d−axis output 0.1% × × f f OPE Detected U1−34 Constant No. for OPE detection f f f f : Even if f is indicated, some constants are not displayed depending on access level. [ Depends on the setting of o1−01. ] 0.1A for models of 11 kW or above. # Not displayed for some models depending on software version No. 75 Table A−3 Monitor Constants List (Cont’d) Digital Operator Function Display Fault Trace Fault History Digital Operator Display Con Constant No. Control Method: (f=Monitor enable, ×=Monitor disable) Constant Name Unit V/f control V/f with PG Feedback Open Loop Vector Flux Vector Current Fault U2−01 Current fault f f f f Last Fault U2−02 Last fault f f f f Frequency Ref U2−03 Frequency reference at fault 0.01 Hz f f f f Output Freq U2−04 Output frequency at fault 0.01 Hz f f f f f f f f Output Current U2−05 Output current at fault 0.01A[ Motor Speed U2−06 Motor speed at fault 0.01 Hz × f f f Output Voltage U2−07 Output voltage reference at fault 0.1V f f f f DC Bus Voltage U2−08 DC bus voltage at fault 1V f f f f Output kWatts U2−09 Output power at fault 0.1 kW f f f f Torque Reference U2−10 Torque reference at fault 0.1% × × f f Input Term Sts U2−11 Input terminal status at fault f f f f Output Term Sts U2−12 Output terminal status at fault f f f f Inverter Status U2−13 Operation status at fault f f f f Elapsed Time U2−14 Cumulative operation time at fault 1H f f f f Last Fault U3−01 Most recent fault f f f f Fault Message 2 U3−02 Second most recent fault f f f f Fault Message 3 U3−03 Third most recent fault f f f f Fault Message 4 U3−04 Fourth / Oldest fault f f f f Elapsed Time 1 U3−05 Cumulative operation time at fault 1H f f f f Elapsed Time 2 U3−06 Accumulated time of second fault 1H f f f f Elapsed Time 3 U3−07 Accumulated time of third fault 1H f f f f U3−08 Accumulated time of fourth / oldest fault 1H f f f f Elapsed Time 4 : Even if f is indicated, some constants are not displayed depending on access level. [ 0.1A for models of 11kW or above. Note: If another fault occurs (i.e. fifth fault), then the oldest fault (U3−04) is lost. The fifth fault now becomes the most recent fault (U3−01) and all the other faults move down one step. 76 APPENDIX 4 Table A−4 CONSTANTS LIST Constants List The initial settings are for open loop vector control (A1−02=2), 15 kW models. Constant No. A1−00 Name (Digital Operator Display) 1 User Setting Constant No. Name (Digital Operator Display) Initial Setting b6−01 Dwell frequency at start (Dwell Ref @ Start) 0.0 2 b6−02 0.0 2 b6−03 Dwell time at start (Dwell Time @ Start) Dwell frequency at stop (Dwell Ref @ Stop) Initialize (Init Parameters) Password 1 (Enter Password) 0000 b6−04 0.0 0000 b7−01 Dwell time at stop (Dwell Time @ Stop) Droop control gain [ (Droop Gain) A1−05 Password 2 (Select Password) 0000 b7−02 0.05 A2−01 to A2−32 User setting constant (User Param 1 to 32) Reference selection (Reference Source) Operation method selection (Run Source) Stopping method selection (Stopping Method) Prohibition of reverse operation (Reverse Oper) Operation selection for setting of E1−09 or less (Zero−Speed Oper) Read sequence input twice (Cntl Input Scans) − b8−01 1 b8−02 1 b9−01 0 b9−02 0 C1−01 0 C1−02 1 C1−03 0 C1−04 Droop control delay time [ (Droop Delay Time) Energy−saving gain (Energy Save Gain) Energy−saving frequency (Energy Save Freq) Zero−servo gain (Zero Servo Gain) Zero−servo completion width (Zero Servo Count) Acceleration time 1 (Accel Time 1) Deceleration time 1 (Decel Time 1) Acceleration time 2 (Accel Time 2) Deceleration time 2 (Decel Time 2) 0.5 C1−05 10.0 50 C1−06 0.00 C1−07 0.50 C1−08 0 C1−09 Acceleration time 3 (Accel Time 3) Deceleration time 3 (Decel Time 3) Acceleration time 4 (Accel Time 4) Deceleration time 4 (Decel Time 4) Emergency stop time (Fast Stop Time) A1−01 A1−02 A1−03 A1−04 b1−01 b1−02 b1−03 b1−04 b1−05 b1−06 b1−07 Language selection for digital operator display (Select Language) Initial Setting Constant access level (Access Level) Control method selection (Control Method) : : Operation selection after switching to remote mode [ (LOC/REM RUN Sel) b2−01 b2−02 b2−03 b2−04 b3−01 Zero speed level (DC injection braking starting frequency) (DCInj Start Freq) DC injection braking current (DCinj Current) DC injection braking time at start (DCInj Time @ Start) DC injection braking time at stop (DCInj Time @ Stop) Speed search selection at start (SpdSrch at Start) ] 0.0 0.0 80 0.0 5 10 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 b3−02 Speed search operating current (SpdSrch Current) 100 C1−10 Accel/decel time setting unit (Acc/Dec Units) 1 b3−03 Speed search deceleration time (SpdSrch Dec Time) Timer function ON−delay time (Delay−ON Timer) Timer function OFF−delay time (Delay−OFF Timer) PID control mode selection (PID Mode) Proportional gain (P) (PID Gain) Integral (I) time (PID I Time) Integral (I) limit (PID I Limit) Differential (D) time (PID D Time) PID limit (PID Limit) PID offset adjustment (PID Offset) 2.0 C1−11 0.00 0.0 C2−01 0.0 C2−02 0 C2−03 1.00 C2−04 1.0 C3−01 100.0 C3−02 0.00 C3−03 100.0 C3−04 0.0 C3−05 0.00 C4−01 Accel/decel time switching frequency (Acc/Dec SW Freq) S−curve characteristic time at acceleration start (SCrv Acc @ Start) S−curve characteristic time at acceleration end (SCrv Acc @ End) S−curve characteristic time at deceleration start (SCrv Dec @ Start) S−curve characteristic time at deceleration end (SCrv Dec @ End) Slip compensation gain (Slip Comp Gain) Slip compensation primary delay time (Slip Comp Time) Slip compensation limit (Slip Comp Limit) Slip compensation selection during regeneration (Slip Comp Regen) Flux calculation method (Flux Select) Torque compensation gain (Torq Comp Gain) b4−01 b4−02 b5−01 b5−02 b5−03 b5−04 b5−05 b5−06 b5−07 b5−08 ] PID primary delay time constant (PID Delay Time) : Not initialized. User Setting 0.20 0.20 0.20 0.00 1.0 ] 200 ] 200 0 0 1.00 (Domestic standard specifications: A1−01=1, A1−02=2) [ Not displayed for some models depending on software version No. ] Differs depending on the control method selection (A1−02). 77 Table A−4 Constants List (Cont’d) Constant No. C4−02 C5−01 C5−02 C5−03 C5−04 C5−05 C5−06 C5−07 C5−08 C6−01 C6−02 C6−03 C7−01 C7−02 C8−08 C8−30 d1−01 d1−02 d1−03 d1−04 d1−05 d1−06 d1−07 d1−08 d1−09 d2−01 d2−02 d3−01 d3−02 d3−03 d3−04 Name (Digital Operator Display) Torque compensation time constant (Torq Comp Time) ASR proportional (P) gain 1 (ASR P Gain 1) Initial Setting User Setting Constant No. Name (Digital Operator Display) 20 d4−01 Frequency reference hold function selection (MOP Ref Memory) 0 20.00 d4−02 25 ASR integral (I) time 1 (ASR I Time 1) ASR proportional (P) gain 2 (ASR P Gain 2) ASR integral (I) time 2 (ASR I Time 2) ASR limit (ASR Limit) ASR primary delay time (ASR Delay Time) ASR switching frequency (ASR Gain SW Freq) ASR integral (I) limit [ (ASR I Limit) Carrier frequency upper limit (Carrier Freq Max) Carrier frequency lower limit (Carrier Freq Min) Carrier frequency proportional gain (Carrier Freq Gain) Hunting prevention selection (Hunt Prev Select) Hunting prevention gain (Hunt Prev Gain) AFR gain (AFR Gain) Carrier frequency selection during auto−tuning [ (Carrier in tune) Frequency reference 1 (Reference 1) Frequency reference 2 (Reference 2) Frequency reference 3 (Reference 3) Frequency reference 4 (Reference 4) 0.500 d5−01 20.00 d5−02 0.500 d5−03 5.0 d5−04 0.004 d5−05 0.0 d5−06 400 E1−01 10.0 E1−02 10.0 E1−03 0 E1−04 1 E1−05 1.00 E1−06 1.00 E1−07 2 E1−08 0.00 E1−09 0.00 E1−10 0.00 E1−11 0.00 E1−12 Frequency reference 5 (Reference 5) Frequency reference 6 (Reference 6) Frequency reference 7 (Reference 7) Frequency reference 8 (Reference 8) Jog frequency reference (Jog Reference) Frequency reference upper limit (Ref Upper Limit) Frequency reference lower limit (Ref Lower Limit) Jump frequency 1 (Jump Freq 1) Jump frequency 2 (Jump Freq 2) Jump frequency 3 (Jump Freq 3) Jump frequency width (Jump Bandwidth) 0.00 E1−13 0.00 E2−01 0.00 E2−02 0.00 E2−03 6.00 E2−04 100.0 E2−05 0.0 E2−06 0.0 E2−07 0.0 E2−08 0.0 E2−09 1.0 E3−01 + − Speed limits [ (Trim Control Lvl) Torque control selection (Torq Control Sel) Torque reference delay time (Torq Ref Filter) Speed limit selection (Speed Limit Sel) Speed limit (Speed Lmt Value) Speed limit bias (Speed Lmt Bias) Speed/torque control switching timer (Ref Hold Time) Input voltage setting (Input Voltage) Motor selection (Motor Selection) V/f pattern selection (V/F Selection) Max. output frequency (Max Frequency) Max. voltage (Max Voltage) Base frequency (Base Frequency) Mid. output frequency (Mid Frequency A) Mid. output frequency voltage (Mid Voltage A) Min. output frequency (Min Frequency) Min. output frequency voltage (Min Voltage) Mid. output frequency 2 [ (Mid Frequency B) Mid. output frequency voltage 2 [ (Mid Voltage B) Base voltage [ (Base Voltage) Motor rated current (Motor Rated FLA) Motor rated slip (Motor Rated Slip) Motor no−load current (No−Load Current) Number of motor poles (Number of Poles) Motor line−to−line resistance (Term Resistance) Motor leak inductance (Leak Inductance) Motor iron−core saturation coefficient 1 (Saturation Comp 1) Motor iron−core saturation coefficient 2 (Saturation Comp 2) Motor mechanical loss (Mechanical Loss) Motor 2 control method selection [ (Control Method) : : : : : ] ] ] : Differs depending on the control method selection (A1−02). [ Not displayed for some models depending on software version No. ] Setting unit and initial setting differ depending on inverter capacity. 78 Initial Setting 0 0 1 0 10 0 575 0 0F 60 575 60 3.0 : 31.6 : 0.5 : 5.7 : 0.0 0.0 0.0 22 ] 1.6 ] 6.6 ] 4 0.896 ] 19.2 ] 0.50 0.75 0.0 2 User Setting APPENDIX 4 CONSTANTS LIST Table A−4 Constants List (Cont’d) Constant No. E4−01 E4−02 E4−03 E4−04 Name (Digital Operator Display) Motor 2 max. output frequency : (V/F2 Max Freq) Motor 2 max. voltage : (V/F2 Max Voltage) Motor 2 max. voltage frequency : (V/F2 Base Freq) Motor 2 mid. output frequency 1 : (V/F2 Mid Freq) Initial Setting User Setting Constant No. 60 F4−03 575 F4−04 60.0 F5−01 3.0 F5−02 [ Name (Digital Operator Display) Channel 2 monitor selection (AO Ch2 Select) Channel 2 gain (AO Ch2 Gain) Channel 1 output selection (DO−02 Ch1 Select) Channel 2 output selection (DO−02 Ch2 Select) Initial Setting 3 0.50 0 1 E4−05 Motor 2 mid. output frequency voltage 1 : (V/F2 Mid Voltage) 31.6 F6−01 Output mode selection (DO−08 Selection) 0 E4−06 Motor 2 min. output frequency : (V/F2 Min Freq) 0.5 F7−01 Frequency multiple selection (PO−36F Selection) 1 E4−07 Motor 2 min. output frequency voltage : (V/F2 Min Voltage) 5.7 H1−01 Multi−function input (terminal 3) (Terminal 3 Sel) 24 E5−01 Motor 2 rated current : (Motor 2 rated FLA) 22 H1−02 Multi−function input (terminal 4) (Terminal 4 Sel) 14 E5−02 Motor 2 rated slip : (Motor 2 Slip Freq) 1.6 H1−03 Multi−function input (terminal 5) (Terminal 5 Sel) 3(0) # E5−03 Motor 2 no−load current : (Motor 2 No−load I) 6.6 H1−04 Multi−function input (terminal 6) (Terminal 6 Sel) 4(3) # E5−04 Motor 2 number of poles : (Motor 2 # Poles) Motor 2 line−to−line resistance : (Motor 2 term Ohms) 4 H1−05 0.896 H1−06 Multi−function input (terminal 7) (Terminal 7 Sel) Multi−function input (terminal 8) (Terminal 8 Sel) 6(4) # 8(6) # Motor 2 leak inductance : (Motor 2 Leak) PG constant (PG Pulse/Rev) Operation selection at PG open circuit (PG Fdbk Loss Sel) Operation selection at overspeed (PG Overspeed Sel) Operation selection at deviation (PG Deviation Sel) PG rotation (PG Rotation Sel) PG division rate (PG pulse monitor) (PG Output Ratio) Integral value during accel/decel enable/disable (PG Ramp PI/I Sel) Overspeed detection level (PG Overspd Level) Overspeed detection delay time (PG Overspd Time) 17.2 H2−01 Multi−function input (terminal 9−10) (Terminal 9 Sel) 0 600 H2−02 1 1 H2−03 1 H3−01 3 H3−02 0 H3−03 1 H3−04 0 H3−05 115 H3−06 0.0 H3−07 Multi−function input (terminal 25−27) (Terminal 25 Sel) Multi−function input (terminal 26−27) (Terminal 26 Sel) Signal level selection (terminal 13) (Term 13 Signal) Gain (terminal 13) (Terminal 13 Gain) Bias (terminal 13) bias (Terminal 13 Bias) Signal level selection (terminal 16) (Term 16 Signal) Multi−function analog input (terminal 16) (Terminal 16 Sel) Gain (terminal 16) (Terminal 16 Gain) Bias (terminal 16) (Terminal 16 Bias) Excessive speed deviation detection level (PG Deviate Level) Excessive speed deviation detection delay time (PG Deviate Time) Number of PG gear teeth 1 (PG# Gear Teeth 1) Number of PG gear teeth 2 (PG# Gear Teeth 2) PG open−circuit detection time : (PGO Time) Bi−polar or uni−polar input selection (AI−14 Input Sel) Digital input option (DI Input) Channel 1 monitor selection (AO Ch1 Select) Channel 1 gain (AO Ch1 Gain) 10 H3−08 0.5 H3−09 0 H3−10 0 H3−11 2.0 H3−12 0 H4−01 0 H4−02 2 H4−03 1.00 H4−04 E5−05 E5−06 F1−01 F1−02 F1−03 F1−04 F1−05 F1−06 F1−07 F1−08 F1−09 F1−10 F1−11 F1−12 F1−13 F1−14 F2−01 F3−01 F4−01 F4−02 [ [ [ ] ] ] ] ] [ Signal level selection (terminal 14) (Term 14 Signal) Multi−function analog input (terminal 14) (Terminal 14 Sel) Gain (terminal 14) (Terminal 14 Gain) Bias (terminal 14) (Terminal 14 Bias) Analog input filter time constant (Filter Avg Time) Monitor selection (terminal 21) (Terminal 21 Sel) Gain (terminal 21) (Terminal 21 Gain) Bias (terminal 21) (Terminal 21 Bias) Monitor selection (terminal 23) (Terminal 23 Sel) User Setting 2 0 100.0 0.0 0 0 100.0 0.0 2 1F 100.0 0.0 0.00 2 1.00 0.0 3 : Not displayed for some models depending on software version No. [ Differs depending on the control method selection (A1−02). ] Setting unit and initial setting differ depending on inverter capacity. # Initial settings in the parentheses are values obtained at 3−wire initialization. 79 Table A−4 Constants List (Cont’d) Constant No. H4−05 Name (Digital Operator Display) Initial Setting User Setting Constant No. Gain (terminal 23) (Terminal 23 Gain) Bias (terminal 23) (Terminal 23 Bias) Analog output signal level selection (AO Level Select) Station address (Serial Comm Adr) Communication speed selection (Serial Baud Rate) Communication parity selection (Serial Com Sel) Stopping method after communication error (Serial Fault Sel) Communication error detection selection : (Serial Flt Dtct) Motor protection selection (MOL Fault Select) Motor protection time constant (MOL Time Const) Momentary power loss detection (PwrL Selection) Momentary power loss ridethru time (PwrL Ridethru t) 0.50 L6−02 0.0 L6−03 0 L6−04 1F L6−05 3 L6−06 0 L7−01 3 L7−02 1 L7−03 1 L7−04 1.0 L8−01 0 L8−02 2.0 L8−03 L2−03 Min. baseblock time (PwrL Baseblock t) 0.5 L2−04 Voltage recovery time (PwrL V/F Ramp t) L2−05 Undervoltage detection level (PUV Det Level) Stall prevention selection during accel (StallP Accel Sel) Stall prevention level during accel (StallP Accel Lvl) Stall prevention limit during accel (StallP CHP Lvl) Stall prevention selection during decel (StallP Decel Sel) Stall prevention selection during running (StallP Run Sel) Stall prevention level during running (StallP Run Level) Speed agree detection level (Spd Agree Level) Speed agree detection width (Spd Agree Width) Speed agree detection level (+/−) (Spd Agree Lvl + −) Speed agree detection width (+/−) (Spd Agree Wdth + −) Operation when frequency reference is missing (Ref Loss Sel) Number of auto restart attempts (Num of Restarts) Auto restart operation selection (Restart Sel) Torque detection selection 1 (Torq Det 1 Sel) H4−06 H4−07 H5−01 H5−02 H5−03 H5−04 H5−05 L1−01 L1−02 L2−01 L2−02 L3−01 L3−02 L3−03 L3−04 L3−05 L3−06 L4−01 L4−02 L4−03 L4−04 L4−05 L5−01 L5−02 L6−01 Name (Digital Operator Display) Torque detection level 1 (Torq Det 1 Lvl) Torque detection time 1 (Torq Det 1 Time) Torque detection selection 2 (Torq Det 2 Sel) Torque detection level 2 (Torq Det 2 Lvl) Torque detection time 2 (Torq Det 2 Time) Forward torque limit (Torq Limit Fwd) Reverse torque limit (Torq Limit Rev) Forward regenerative torque limit (Torq Lmt Fwd Rgn) Reverse regenerative torque limit (Torq Lmt Rev Rgn) Protect selection for internal DB resistor (DB Resistor Prot) Overheat pre−alarm level (OH Pre−Alarm Lvl) Operation selection after overheat pre−alarm (OH Pre−Alarm Sel) 150 L8−05 Input open−phase protection selection (Ph Loss In Sel) 0 0.3 L8−07 Output open−phase protection selection (Ph Loss Out Sel) 0 546 o1−01 6 1 o1−02 150 o1−03 50 o1−04 1 o1−05 1 o2−01 160 o2−02 0.0 o2−03 2.0 o2−04 0.0 o2−05 Monitor selection (Monitor Select) Monitor selection after power up (Power−On Monitor) Frequency units of reference setting and monitor (Display Scaling) Frequency units of constant setting (Display Units) Constant No. display selection (Address Display) LOCAL/REMOTE key enable/disable (Local/Remote Key) STOP key during control circuit terminal operation (Oper STOP Key) User constant initial value (User Defaults) kVA selection (Inverter Model #) Frequency reference setting method selection : (Operator M.O.P.) 2.0 o2−06 0 o2−07 0 o2−08 0 o2−09 [ [ [ ] Operation selection when digital operator is disconnected (Oper Detection) Cumulative operation time setting (Elapsed Time Set) Cumulative operation time selection (Elapsed Time Run) Initialize mode selection : (Init Mode Sel) 0 : Not displayed for some models depending on software version No. [ Setting unit and initial setting differ depending on inverter capacity. ] Differs depending on the control method selection (A1−02). # Differs depending on area. 80 Initial Setting 0.1 0 150 0.1 200 200 200 200 0 95 3 1 0 0 0 1 1 0 48 [ 0 0 − 0 2 # User Setting APPENDIX 4 Table A−5 Set Value Multi−digital Output Function Name 00 During RUN 1 01 02 Set Value Function Name 10 Minor Fault Zero Speed 11 Reset Cmd Active Fref/Fout Agree 1 12 Timer Output 03 Fref/Set Agree 1 13 Fref/Fout Agree 2 04 Freq Detect 1 14 Fref/Set Agree 2 05 Freq Detect 2 15 Freq Detect 3 06 Inverter Ready 16 Freq Detect 4 07 DC Bus undervolt 17 Trq Det 1 N.C. 08 BaseBlk 1 18 Trq Det 2 N.O. 09 Option Reference 19 Trq Det 2 N.C. 0A Remote Operation 1A Reverse Dir 0B Trq Det 1 N.O. 1B BaseBlk 2 0C Loss of Ref 1C Motor 2 Selected 0D DB Overheat 1D Regenerating 0E Fault 1E Restart Enabled 0F Not Used 1F Overload (OL1) 20 OH Prealarm 21−2F Set Value Not Used 30 Current / Trq LIM 31 Speed Limit 32 Not Used 33 Zero Servo End 34 During RUN 2 35−3F Table A−6 Not Used Multi−analog Input Function Name 00 Aux Reference 01 02 Set Value Function Name 10 Fwd Torque Limit Frequency Gain 11 Rev Torque Limit Frequency Bias 12 Regen Torq Limit 03 Voltage Bias 13 Torque Reference 04 Acc/Dec Change 14 Torque Comp 05 DCInj Current 15 Speed Limit 06 OverTorque Level 16−1F Not Used 07 Stall Prev Level 08 Ref Lower Limit 09 Jump Frequency 0A PID Feedback 0B−0F CONSTANTS LIST Not Used 81 Table A−7 Constants Array Group MENU U Operation U Monitor A Initialize Programming b Application Modified constants Auto−tuning C Tuning d Constant No. B A Q U1 U2 U3 Monitor Fault trace Fault history 01−14 01−14 01−08 A1 A2 Initialize User constants 00−04 b1 b2 b3 b4 b5 b6 b7 b8 b9 Sequence DC braking Speed search Delay timers PID control Reference hold Droop control Energy saving Zero servo 01−03 C1 C2 C3 C4 C5 C6 C7 C8 Accel/decel S−curve accel/decel Motor−slip compensation Torque compensation ASR tuning Carrier frequency Hunting prevention Factory tuning 01, 02 d1 d2 d3 d4 d5 Preset reference Reference limit Jump frequency Sequence Torque control 01−04, 09 15−19 04 01−04 03, 04, 09 01 01 01−04 01 05−07 04 05−08, 10, 11 01−04 02−04 04 02 05−07 02, 03 01 02−04 01−28 01, 02 01−04 V/f pattern 1 Motor setup 1 Motor 2 control method V/f pattern 2 Motor setup 2 01−10 01−04 F Option F1 F2 F3 F4 F5 F6 F7 PG option setup AI−14 setup DI−08, 16 setup AO−08 setup DO−02 setup DO−08 setup PO−36F setup 01 H Terminal H1 H2 H3 H4 01−06 01−03 01−07 01−06 H5 Digital inputs Digital outputs Analog inputs Analog outputs Serial communication setup L1 L2 L3 L4 L5 L6 L7 L8 Motor overload Power loss ride−thru Stall prevention Reference detection Fault restart Torque detection Torque limit Hardware protection 01, 02 01−03 01, 02, 04−06 01, 02 01, 02 01−03 o1 o2 Monitor select Key select Operator 05−07 05−08 01, 02 01−04 E1 E2 E3 E4 E5 o 20−29 01−03 01, 02 01−08 01−04 01, 02 01, 02 01, 02 Motor Protection F 01−32 E L 82 Reference Function 11−13 05−09 01 01−07 01−05 02−07 01 01 01−04 01, 02 01 01 08−13 08−12 01−04 01−04 04, 05 03 03−05 07, 08 04−06 01 05, 06 02, 03, 05, 07 04, 06, 07−13 01−04 01−04 05 05−08 A A/D converter fault in analog speed reference card . . . . . . . . . . . 66 AC reactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 accel/decel time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 acceleration time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 access level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51, 53 ADVANCED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51, 53 allowable current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 allowable frequency fluctuation . . . . . . . . . . . . . . . . . . . . . . . . . 68 allowable voltage fluctuation . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61, 69 analog input signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 analog output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 applicable standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 approx. mass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 ASR integral time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 ASR proportional gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 auto restart operation selection . . . . . . . . . . . . . . . . . . . . . . . . . 80 auxiliary frequency reference . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 B base frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 baseblock circuit fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 BASIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51, 53 bias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 blown fuse protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 braking resistor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 25, 71 braking resistor unit overheat . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 braking torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 braking transistor failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 C cable gland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 carrier frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 78 closed−loop connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 constant setting fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 constant setting range fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 constants array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 constants list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 control characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 control circuit fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 control circuit terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 control circuit terminal signal . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 control circuit undervoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 control fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 control method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52, 68, 75 control method selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 control method selection fault . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 control PC board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7, 60 cooling fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 CPU external A/D converter fault . . . . . . . . . . . . . . . . . . . . . . . . 66 CPU internal A/D converter fault . . . . . . . . . . . . . . . . . . . . . . . . 66 cumulative operation time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 D DC bus voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 DC injection braking current . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 DC injection braking time at start . . . . . . . . . . . . . . . . . . . . . . . 77 DC injection braking time at stop . . . . . . . . . . . . . . . . . . . . . . . 77 DC reactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 deceleration time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 digital input option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 digital operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12, 38, 44 digital operator connection fault . . . . . . . . . . . . . . . . . . . . . . . . . 64 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 E EEPROM fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 EEPROM writing fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 electronic thermal overload relay . . . . . . . . . . . . . . . . . . . . . . . . 69 elevation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 EMC standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 emergency stop circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4, 17 enclosed wall−mounted type . . . . . . . . . . . . . . . . . . . . . . . . 11, 69 enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 external baseblock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 30 external fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 30 F fault contact output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 50, 62 fault diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62, 63 fault display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 fault reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 30 flux vector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 fly−wheel diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 forward regenerative torque limit . . . . . . . . . . . . . . . . . . . . . . . 80 forward run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 forward torque limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 frequency accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 frequency control range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 frequency multiple selection . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 frequency reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36, 75, 78 frequency resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 frequency setting power supply . . . . . . . . . . . . . . . . . . . . . . . . . . 18 frequency setting signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 frequency units of constant setting . . . . . . . . . . . . . . . . . . . . . . 80 frequency units of reference setting and monitor . . . . . . . . . . . . 80 fuse blown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 G gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 ground fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 ground fault interrupter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 ground terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4, 21 grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23, 24, 63 83 H heatsink overheat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63, 69 humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 I initialize mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 input fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 input open−phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 input terminal status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 input voltage setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 instantaneous overcurrent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 intake air temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 integral value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 internal control status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 inverter capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 inverter overload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 J jog frequency reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 jog reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 jump frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 K kVA selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 kVA selection fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 L line filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 load short−circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 LOCAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 M magnetic contactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 23 magnetic starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 main circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 main circuit configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 main circuit power supply . . . . . . . . . . . . . . . . . . . . . . . . . 5, 21, 60 main circuit terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 main circuit undervoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 master frequency reference . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 30 Max. applicable motor output . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 max. applicable motor output . . . . . . . . . . . . . . . . . . . . . . . 11, 68 max. output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 max. output voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 max. voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 MC fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 MEMOBUS control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 mid. output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 mid. output frequency voltage . . . . . . . . . . . . . . . . . . . . . . . . . . 78 min. baseblock time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 min. output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 min. output frequency voltage . . . . . . . . . . . . . . . . . . . . . . . . . . 78 modified constants mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 84 momentary power loss . . . . . . . . . . . . . . . . . . . . . . . . . . 63, 69, 80 monitor selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 monitor selection after power up . . . . . . . . . . . . . . . . . . . . . . . . 80 motor no−load current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 motor overload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 motor overload protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 motor protection selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 motor protection time constant . . . . . . . . . . . . . . . . . . . . . . . . . 80 motor rated current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 motor rated slip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 motor selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 motor speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 multi−analog input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 multi−digital Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 multi−function analog input . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 30 multi−function analog input selection fault . . . . . . . . . . . . . . . . . 65 multi−function analog output . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 multi−function contact input . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 multi−function contact input selection fault . . . . . . . . . . . . . . . . . 65 multi−function contact outpu . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 multi−function input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 multi−function open collector output . . . . . . . . . . . . . . . . . . . . . . 18 multi−step speed reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 multi−step speed setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 N Nameplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 nameplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 NPN transistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 number of auto restart attempts . . . . . . . . . . . . . . . . . . . . . . . . . 80 number of motor poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 O open chassis type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11, 69 open loop vector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51, 52 open phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 operation method selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 operation mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 operation reference fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 option connection fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 option reference selection fault . . . . . . . . . . . . . . . . . . . . . . . . . . 65 opto−coupler output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 output characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 75 output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 75 output frequency resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 output mode selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 output open−phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 output power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 output selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 output terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 output terminal status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 output voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 overcurrent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50, 63 overload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 overload capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 overload relay trip contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 overspeed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 overtorque detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 overvoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63, 69 P periodic inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 PG constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 PG division rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 PG open circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64, 79 PG rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 phase advancing capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 photo−coupler insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 PNP transistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 power charge indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 programming mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 prohibition of reverse operation . . . . . . . . . . . . . . . . . . . . . . . . . 77 protect selection for internal DB resistor . . . . . . . . . . . . . . . . . . 80 protective functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Q QUICK−START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51, 53 R rated input voltage and frequency . . . . . . . . . . . . . . . . . . . . . . . 68 rated output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 rated output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 reference selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 REMOTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 reverse regenerative torque limit . . . . . . . . . . . . . . . . . . . . . . . . 80 reverse run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 reverse torque limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 S sequence common . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 sequence input internal common . . . . . . . . . . . . . . . . . . . . . . . . . 30 sequence input signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 sequence output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Serial Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 serial communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 shield sheath connection terminal . . . . . . . . . . . . . . . . . . . . . . . . 18 shielded wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 shortcircuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 SI−B transmission error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 signal level selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 sine wave PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 slip compensation gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 software No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 speed agree detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 speed agree detection level . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 speed agree detection width . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 speed agree signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 speed control accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 speed control range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 speed deviation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 speed response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 stall prevention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 stall prevention level during accel . . . . . . . . . . . . . . . . . . . . . . . 80 stall prevention selection during accel . . . . . . . . . . . . . . . . . . . . 80 stall prevention selection during decel . . . . . . . . . . . . . . . . . . . . 80 stall prevention selection during running . . . . . . . . . . . . . . . . . . 80 starting torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 STOP key during control circuit terminal operation . . . . . . . . . . 80 stopping method selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 surge suppressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 switching frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 T test run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37, 38 thermal overload relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 thermistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 torque accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 torque compensation gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 torque detection level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 torque detection selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 torque detection time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 torque limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 transmission error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 twisted−pair shielded wire . . . . . . . . . . . . . . . . . . . . . . . . . . . 20, 31 U undervoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . user constant initial value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 80 V V/f control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51, 52 V/f control with PG feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 V/f data setting fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 V/f pattern selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 VS operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 W Warning Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 wire size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 withstand voltage test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5, 17 Z zero speed detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 zero speed level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 zero speed signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 zero−servo fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 85 ">
/
Ladda ner
Bara en vänlig påminnelse. Du kan visa dokumentet här. Men viktigast av allt, vår AI har redan läst det. Den kan förklara komplexa saker på ett enkelt sätt, svara på dina frågor på vilket språk som helst och hjälpa dig att snabbt navigera även de längsta eller mest komplicerade dokumenten.
Annons