Burkert 8025 Insertion flowmeter or batch controller Data Sheet
Add to my manuals1 Pages
Burkert 8025 is a versatile batch controller designed for precise liquid dosing in various industrial applications. With seven selectable preset programs, it offers flexible dosing options. The Teach-In function enables automatic calibration, ensuring accurate measurements. The controller features local and remote dosing modes, allowing for manual or automated operation. It also provides batch status and alarm messages through its polarized, potential-free outputs. With compatibility for Bürkert flow sensors and other compatible devices, the 8025 offers reliable flow control solutions.
advertisement
8025
Controller Batch System
Single or Multi 8025 Controller
Batch System
• Batched volume and totalizers displayed
• Simulation: all output signals provided without need of real fl ow
• Seven selectable preset programs
• Automatic calibration: Teach-In
• Customisation available on request
• Enclosures available in mild and stainless steel and plastic/GRP
• Full set of drawings and tags
• Installation and commissioning available upon request
The batch controller is specially designed for use in neutral and slightly aggressive, solid-free liquids.
• Local dosing:
The user enters the quantity to be metered and initiates the dosage from the keypad.
• Local dosing with pre-set quantity:
The user selects a quantity which has been preset and initiates the dosage from the keypad.
• Remote control dosing:
Using a rotary knob (selecting a pre-set quantity) or binary data inputs.
• Dosing controlled by a PLC unit:
Using binary data inputs.
• Automatic dosing controlled by variation of pulse duration.
The quantity of the dose is directly proportional to the duration of a pulse.
Indication in operating mode / Display
• Dosing amount
• Dosing mode
• Main totalizer
• Daily totalizer with reset function Parameter defi nition
• Language
• Engineering units
• K-factor / TEACH-IN function
• Selection of dosing mode
• Over-run correction
• Alarm
• Function mode of relays
• Reset main totalizer Test
• Display of state of binary inputs
• Relay test
• Frequency test
Technical Data
Electrical connection
Connection cable
Protection Class
Relative humidity
Ambient temperature
Electrical Data
Compatibility
Power Supply
Current consumption
Sensor input
Sensor Output
Voltage supply
Current consumption
Input
Output
Batch status
To fi nd your nearest Burkert facility, click on the orange box → www.burkert.com
Via Terminals Mounted in the enclosure
Shielded, max. 1.5mm2
Display IP65, Enclosure IP66
< 80%, without condensation
0 up to +60 deg C
Bürkert fl ow sensor with frequency output
(8020,8030, 8030HT, 8041, 8031, 8070,8071) and other sensors with compatible electrical data.
115/230V AC 50/60Hz
< 2.5A
2.5 up to 700 Hz – Open collector NPN, Coil, TTL,
CMOS
12...30 V DC or 0...18 V DC
Max. Current available from controller: 100 mA
4 binary inputs, 5...30 V DC
Polarized, potential free, 5...30 V DC; 100 mA,
Protected , line drop at 100mA: 1.5V DC – for status and alarm message 2 relays, freely programmable, 3A
230v AC
In case of special application conditions, please consult for advice.
© Christian Bürkert GmbH & Co. KG www.burkert.com
p. 1/2
120
3
/1_EU-en_00895210