Suburban P-30S Service Manual

Add to My manuals
48 Pages

advertisement

Suburban P-30S Service Manual | Manualzz

Suburban

RV FURNACES

SERVICE MANUAL

DD-

17DSI • DD-17DSIW

NT-

12S/SE • NT-16S/SE • NT-20S/SE

NT24SP • NT-30SP • NT-34SP

NT-40

P-30S/40

SF-

20 • SF-25 • SF-30 • SF-35 • SF-42

SF-

20F • SF-25F • SF-30F • SF-35F • SF-42F

SH35 • SH-42

SH35F • SH-42F

SHD-2542

SFV-

35 • SFV-42

SFV-

35F • SFV-42F

SUBURBAN MANUFACTURING COMPANY

676 Broadway Street

Dayton, Tennessee 37321

423-775-2131

Fax: 423-775-7015 www.rvcomfort.co

m [email protected]

TABLE OF CONTENTS

Page

General Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Furnace Spec Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Vent Assembly

Illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-16

Return Air Illustrations

Ducting Illustrations

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Installation Requirements (DD, NT and P Model Furnaces) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Installation

Requirements (SF, SH and SHD-2542 Model Furnaces) . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Installation Requirement (SFV Model Furnaces) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Furnace

Specifications (DD, NT and P Model Furnaces) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Furnace Specifications (SF, SFV, SH, and SHD-2542 Model Furnaces)

Sequence of Operation (Time Delay Relay Equipped Furnaces)

. . . . . . . . . . . . . . . . . . . . . . . 22

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Sequence of Operation (Fan Control Module Board (520820) Equipped Furnaces) . . . . . . . . . . . . . . . 24

Sequence of Operation (24 VAC Fan Control Module Board (520947) . . . . . . . . . . . . . . . . . . . . . . . . . 25

Sequence of Operation (SHD-2542 Furance) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Trouble Shooting Flow Chart (Furnaces Equipped with Time Delay Relay) . . . . . . . . . . . . . . . . . . . . . 27

Trouble Shooting Flow Chart (Furnaces Equipped with Fan Control Module Board) . . . . . . . . . . . . . . 28

Service Hints, Diagnosis and Corrective Measures for Suburban 24-Volt AC Electronic Ignition Furnaces . . . . . . . . .

. . . . . . . . . . . . . . . . . . . 29-30 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . 30-34

Furnace Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-36

SF, SH and SHD-2542 Electrode Gap Specifications & Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

NT and Park Model Electrode Gap Specifications & Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Cautions & Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back Cover

NOTE: Our service technicians are available to assist you in making repairs or parts replacements from 8:00 a.m. to 5:00 p.m. Eastern Standard Time, Monday through Friday (except holidays), by calling 423-775-2131 extension 7102. E-mail address: [email protected]

GENERAL SERVICE INFORMATION

Suburban DYNATRAIL furnaces installed in recreational vehicles are classified as Direct Vent Sealed Combustion Furnaces. A forced draft furnace utilizes a sealed combustion chamber which is vented to the outside atmosphere. The intake air for combustion is also taken from outdoors and is completely isolated from the room air. A motor is used to drive an impeller wheel to draw intake air into the chamber to support combustion and force the exhaust gases through the furnace chamber to the outside atmosphere. A second impeller wheel (driven by the same motor yet totally isolated from the combustion air) is used to

2

circulate room air across the furnace chamber where it is heated. The blower then forces the hot air into the living area either through a duct system or through a front grille on the furnace cabinet on direct discharge models.

Suburban furnaces operate on 12-volt DC power which is supplied either by a 12-volt battery or a converter system. A recreational vehicle furnace that is specifically designed for “park model” trailers operates on 120 volts AC. These are designed and tested under the same standards as the 12-volt models.

Suburban forced draft combustion furnaces used in recreational vehicles are designed for use with Propane gas. Although a few recreational vehicle furnaces are approved for use with natural gas, one should never attempt to convert such a unit to natural gas unless the conversion is approved by the manufacturer of the furnace.

Gas Supply Pressure Requirements

Line Pressure:

Minimum 11" WC*, Maximum 14" WC

*WC - water column

Voltage Requirements

Voltage DC: 12 volt D.C.

Minimum 10.5 volts D.C., Maximum 13.5 volts D.C.

Service Tools Required

Manometer gauge/ U-Tube

Volt ohm meter capable of testing above 15 amps

Module board tester #641511

Gas leak detector OR approved leak check liquid

Assorted wrenches

Assorted hand tools

Safety glasses

Suburban

RV FURNACES

12 VDC Direct BTU/h

Discharge Input Height Width

NT-12SE

NT-16SE

12,000

16,000

9 3/8"

9 3/8"

9 3/8"

9 3/8"

Depth Ignition

21-27 3/4" Electronic

21-27 3/4" Electronic

NT-20SE 19,000 9 3/8" 9 3/8"

DD-17DSI 17,000 12" 10 1/2"

Accessories Description

21-27 3/4" Electronic

22-29" Electronic

Shipping

Weight

27

27

27

25

260197

260198

260199

Vent Kit 2" - 4" DD Models

Vent Kit 4" - 6" DD Models

Vent Kit 6" - 9" DD Models

12 VDC Ducted BTU/h

Furnaces

NT-12S

NT-16S

Input Height Width Depth Ignition

12,000 9 3/8" 9 3/8" 22 3/4-29 1/2" Electronic

16,000 9 3/8" 9 3/8" 22 3/4-29 1/2" Electronic

NT-20S 19,000 9 3/8" 9 3/8" 23 3/8-30 1/8" Electronic

Shipping

Weight

27

27

27

3

NT-24SP

NT-30SP

NT-34SP

NT-40

SF-20F

24,000 12 1/2" 12"

30,000 12 1/2" 12"

34,000 12 1/2" 12"

40,000 12 1/2" 12"

20,000 7 1/2" 17"

23"

23"

23"

23"

20"

Electronic

Electronic

Electronic

Electronic

Electronic

40

40

40

42

35

SF-25F

SF-30F

SF-35F

SF-42F

SH-35F

SH-42F

SF-20*

SF-25*

SF-30*

SF-35*

SF-42*

SH-35*

SH-42*

25,000 7 1/2"

30,000 7 1/2"

35,000 7 1/2"

40,000 7 1/2"

35,000 9 1/4"

40,000 9 1/4"

20,000 7 1/2"

25,000 7 1/2"

30,000 7 1/2"

35,000 7 1/2"

40,000 7 1/2"

35,000 9 1/4"

40,000 9 1/4"

17"

17"

17"

17"

17"

17"

17"

17"

17"

17"

17"

17"

17"

20"

20"

20"

20"

20"

20"

20"

20"

20"

20"

20"

20"

20"

Electronic

Electronic

Electronic

Electronic

Electronic

Electronic

Electronic

Electronic

Electronic

Electronic

Electronic

Electronic

Electronic

35

35

35

35

35

35

35

35

40

42

35

40

42

SHD-2542 25/40,000 9 1/4"

Accessories

6258ACW

Description

17" 20" Electronic

*Door, Optional Access, Colonial White, Standard SF Models

6258APW *Door, Optional Access, Polar White, Standard SF Models

44

6267ACW *Door, Optional Access, Colonial White, Standard SH Models

120 VAC Park BTU/h

Model Furnaces Input

P-40 40,000

Height Width

12 1/2" 12"

Accessories Description

Depth

23"

Ignition

Electronic

Shipping

Weight

46

050733

050715

051240

280552

062164

Duct Cover

Duct Collar 4"

Duct Collar 2"

Rain Shield

Bottom Duct Gasket, NT-24/30/34SP, NT-40, P40

4

070853

520009

520576

520753

520864

Wall Thermostats are included with All Models, except SF.

Vent Assemblies are included with all units, except DD.

Bottom Duct Gasket, SF Models Except SF-42, (F)

Bottom Duct Kit W/Gasket, NT-24/30/34SP, NT-40. P40

Bottom Duct Kit W/Gasket, SF Models Except SF-42, (F), SH35 (F)

Bottom Duct Kit W/Gasket and Door, SF-42, (F)

Bottom Duct Kit W/Gasket SH-42 (F) SHD-2542

INSTALLATION

There are several important aspects of the installation which will pertain to all Suburban forced draft furnaces, regardless of the model or the method in which they are installed. They are:

1. Selecting a Location

2. Venting

3. Return Air

4. Ducting

Refer to the furnace installation manual for all installation requirements.

Location and Installation - Locate the furnace near lengthwise center of the coach. Choose a location for installation out of the way of wires, pipes, etc. which might interfere with the installation. Adhere to the minimum clearances from cabinet to combustible construction as listed in the installation manual for your specific furnace model.

Secure furnace cabinet to the floor of the coach using the holes provided in the furnace cabinet.

5

Figure 1

VENTING

Venting - By definition of a Direct Vent Sealed Combustion Furnace, it must be vented to the outside atmosphere and also draw combustion air from outdoors. Therefore, it is imperative that the vent be unobstructed and there must be a seal between the exhaust and intake (caulking) .

Refer to the vent assembly installation in the manual. The vent must be straight. There can be no offsets or turns in the vent. All vent tubes which connect to the furnace exhaust and intake must overlap a minimum of 1/2" on intake, and 1 1/4" on exhaust. Check your furnace model number for vent installation procedures. Vents cannot be altered as supplied from the factory.

VENT ASSEMBLY INSTALLATION (SF and SH SERIES)

6

Figure 2

SF

Figure 2A

SH

VENT ASSEMBLY INSTALLATION (SF and SH SERIES)

7

Figure 3

SF

Figure 3A

SH and SHD-2542

VENT ASSEMBLY INSTALLATION (SF and SH SERIES)

8

Figure 4

SF

Figure 4A

SH

VENT ASSEMBLY INSTALLATION (SFV)

9

Figure 5

Figure 5A

10

Figure 6

11

Figure 6A

VENT ASSEMBLY INSTALLATION (DD SERIES)

Note: Vent cap must be installed on DD furnace when bench testing.

Figure 7

12

VENT ASSEMBLY INSTALLATION (NT SERIES)

Figure 8

NT-12/16/20SE

Figure 9

NT-12/16/20S and SE

Figure 10

NT-12/16S

13

VENT ASSEMBLY INSTALLATION (NT SERIES)

Figure 11

NT-20S

Figure 12

14

VENT ASSEMBLY INSTALLATION (NT SERIES)

NT-24/30/34SP

P-30S

Figure 13

NT-24/30/34SP

P-30

EXTENSION TUBE

KIT NUMBER

520498

520499

520500

520501

MIN./MAX. LENGTH

(Extension Tube Range)

Figure 14

NT-24/30/34SP

P-30S

2-1/4" to 3-1/8"

3-1/8" to 4-7/8"

4-7/8" to 7"

7" to 9"

EXTENSION TUBE

KIT NUMBER

520593

520594

520595

520596

MIN./MAX. LENGTH

(Extension Tube Range)

2-1/4" to 3-1/8"

Figure 15 NT-

40 P-40

3-1/8" to 4-7/8"

4-7/8" to 7"

7" to 9"

15

VENT ASSEMBLY INSTALLATION (NT-40 and P-40)

Figure 16

NT-40

Figure 17

P-40

16

Figure 18

NT-40

P-40

RETURN

AIR

Return Air - The cabinet that the furnace may be installed in will have louvers or openings for the return air back to the furnace. When the furnace is installed, it is imperative that the return air louvers on the furnace cabinet opening are not obstructed.

Usually, these furnaces are installed under a counter, sofa or bed in order to be out of the way. A grille or opening must be built into the cabinetry or into the base area of the sofa or bed. Return air from the living area of the trailer is drawn in through the grille and into the return air openings in the furnace cabinet. Figure 19 illustrates the return air circulation of the furnace. Note:

Refer to the installation manual for the minimum return air area for your specific furnace model.

Insufficient return air will cause the furnace to overheat and cycle on limit. Another symptom of a return air problem is:

1.

Furnace seems to run continuously in an effort to satisfy the thermostat.

*THE TOTAL, FREE, UNOBSTRUCTED RETURN AIR OPENING

TO THE FURNACE MUST NOT BE LESS THAN THE MINIMUM

Figure 19

17

DUCTING

Ducting - Suburban furnaces require that a minimum duct area be maintained throughout entire duct system including through the register. It is very important to adhere to the minimum duct area in order to keep the furnace from cycling on high limit and to assure proper operation of the sail switch (sometimes referred to as a microswitch.) NOTE: (Refer to the installation manual for the minimum ducted square inches area for each model.)

NOTE: Ducts terminating in a dead air space (like holding tank compartments or cargo areas (Toy Boxes) with no means for return air recirculation should not be counted in the required duct area. Also, ducts 2" in diameter or smaller should not be counted in the required duct area.

When installing a duct system, avoid making a lot of turns. The straighter the duct system, the less the resistance to air flow and the better the performance of the furnace.

Avoid making sharp turns in the duct system. Sharp turns will increase the static pressure in the plenum area of the furnace and could cause the furnace to cycle on limit.

The duct connections to the furnace cabinet should be tight to eliminate any heat loss which could result in overheating of the component parts on the furnace as well as a reduction in the heated air flow through the ductwork.

Figure 20

18

FURNACE SPECIFICATIONS

12 VDC

Model Description

Input

BTU/hr

DD-17DSI

Direct

Discharge

17,000

12,000

NT-12S

NT-12SE

NT-16S

NT-16SE

Ducted

Direct

Discharge

Ducted

Direct

Discharge

16,000

19,000

Type Gas

PROPANE

PROPANE

PROPANE

PROPANE

NT-20S

NT-20SE

Ducted

Direct

Discharge

Voltage

12 VDC

12 VDC

12 VDC

12 VDC

Motor

Diameter

3"

3"

3"

3"

NT-24SP

NT-30SP

NT-34SP

NT-40

Park

Models

P-30S

Ducted

Ducted

Ducted

Ducted

Ducted

24,000

30,000

PROPANE

PROPANE

34,000 PROPANE

12 VDC

12 VDC

12 VDC

40,000 PROPANE 12 VDC

30,000 PROPANE 120 VAC

2.5"

2.5"

2.5"

2.5"

3"

Amp Draw

Static

Pressure

C.F.M.

Max.

2.9 n/a 145

2.8

2.8

S - .1" wc

SE - n/a

S - 122

SE -140

S - .1" wc

SE - n/a

S - 165

SE-140

2.8

S - .1" wc

SE-n/a

S - 165

SE-150

3.5

5.5

7.5

9.5

2.5

.2" wc

.2" wc

.1" wc

265

345

373

.155"/.20B 441

.15" wc 345

P-40** Ducted 40,000 PROPANE 120 VAC 3" 2.0 .15" wc 441

NOTES

**P-40 Park Model Furnace and valve is convertible to Natural Gas. Instructions on converting unit to Natural Gas are on sticker on side of cabinet.

FURNACE SPECIFICATIONS

12 VDC

Model

Description

Input

BTU/hr

Type Gas Voltage

Motor

Diameter

Amp Draw

Static

Pressure

C.F.M.

Max.

SF-20/20F Ducted

SF-25/25F Ducted

20,000 PROPANE 12 VDC

25,000 PROPANE 12 VDC

3"

3"

6.5=2.5 in.

Motor

8.5=3 in.

Motor

6.5=2.5 in.

Motor

8.5=3 in.

Motor

.2" wc

.2" wc

300

300

28

SF-30/30F Ducted 30,000 PROPANE 12 VDC

SF-35/35F Ducted 35,000 PROPANE 12 VDC

SF-42/42F Ducted

SFV-20/20F Ducted

SFV-25/25F Ducted

SFV-30/30F Ducted

SFV-35/35F Ducted

SFV-42/42F Ducted

SH-35/35F Ducted

SH-42/42F Ducted

SHD-2542 Ducted

40,000 PROPANE

20,000 PROPANE

12 VDC

12 VDC

25,000 PROPANE

30,000 PROPANE

35,000 PROPANE

40,000 PROPANE

12 VDC

12 VDC

12 VDC

12 VDC

35,000 PROPANE 12 VDC

40,000 PROPANE

25,000

42,000

PROPANE

12 VDC

12 VDC

3"

3"

3"

3"

3"

3"

3"

3"

3"

3"

3"

6.5=2.5 in.

Motor

8.5=3 in.

Motor

8.5=2.5 in.

Motor

9.4=3 in.

Motor

11.5

.2" wc

.2" wc

.25" wc

8.5 .2" wc

8.5

8.5

9.4

11.5

.2" wc

.2" wc

.2" wc

.25" wc

8.2 .2" wc

10.6

8.8 (Low)

12 (High)

.25" wc

.25" wc

300

375

430

300

300

300

375

430

375

430

430

29

SEQUENCE OF OPERATION

For Furnaces Equipped With Time Delay

The thermostat controls the operating circuit to the furnace by reacting to room temperature to open and close a set of contact points which allows current to flow to the ON and OFF switch then to the relay.

The relay receives the power and allows power to pass through to the switch within the relay. This is done by a heater coil within the relay which actuates a bi-metal disc closing the relay circuit.

The power then flows to the motor and allows the blower to operate. One end of the motor shaft drives the room air wheel. The other end of the motor shaft drives the combustion air wheel that delivers the required air to the burner for combustion.

The limit switch is an in-line device which protects the furnace from over heating conditions. The contacts in the limit switch open at a given temperature setting, shutting off power to the ignition system which controls the gas valve.

As the room air wheel comes up to speed, air flow closes sail switch completing the circuit. The sail switch is into the system as a safety to prove there is adequate air

The next operation is controlled by the Direct Spark as power is applied to the DSI board. The system will do

1. The board has a timing circuit which allows the topurge the chamber of any products of combustion or

2. The board will then apply power to the gas

At thesame time it produces a high voltage power supply to the electrode producing spark at the burner.

3. The board will also confirm the presence of a flame. Ifthe flame is not sensed after

7 seconds, the module will try two (2) more times and then go into lock-out. The flame is sensed through the spark wire and electrode.

When the thermostat has reached the set point with the room air temperature, the contacts will open removing power from the controls. The blower will remain on until the relay opens and stops the motor.

NOTE: On some models, sail switch is before limit switch.

the placed for combustion.

Ignition, (DSI) system the following. blower gas. valve.

Time Line

Sequence of Operation for Fan Control Module Board

Part Number 520820

Description - Sequence of Events

30

Start

Thermostat Calls for Heat

15 Seconds Purge

Cycle

The wall thermostat controls the operation of the furnace by reacting to room temperature, this allows current to flow through the On/Off switch to the module board.

The module board constantly checks for a minimum 9.5 volts. If there is not 9.5 volts, the module board will go into a stand by mode until adequate power is supplied. It will then resume normal operation.

Upon a call from the thermostat, the module board thermostat circuit will go active. The sail switch circuit is verified as being open. The blower output is energized. Blower motor starts.

The module board will then verify that the sail switch circuit is closed and motor is up to speed. If this circuit remains open for 30 seconds after the blower motor starts, the module board will go into lock out and shut down the blower motor.

The module board checks that the gas valve relay contacts (which are located on the module board) are open before the ignition sequence starts.

The board has a pre-purge timing circuit of (approximately 15 seconds). This allows the chamber to purge.

7 Seconds Ignition

Cycle and Flame

Sense

The module board will energize the gas valve and enable the high voltage spark output to the electrode for 7 seconds of ignition time.

The module board will then check for flame sense to verify successful lighting of the main burner flame. Sparking will then be terminated and the gas valve and blower outputs will remain energized.

If ignition is successful the module board will monitor the flame sense, sail switch and limit switch circuits, and the thermostat inputs during the heating period.

The flame is sensed through the spark wire and electrode. Therefore, it is essential that the electrode is properly positioned in the burner flame.

2 nd and 3 rd Ignition

Cycles if Required

Heating Cycle

90 Second Shut

Down

3 Try Ignition Board

If the flame is not sensed after seven (7) seconds, a second 15 second purge cycle will begin followed by a second Trial-For-Ignition sequence. After three (3) Trial-For-

Ignition attempts with no ignition of the main burner, the module board will de-energize the gas valve immediately and blower will run for 3 minutes and then shutdown in lockout.

If during the heating cycle, the limit switch circuit opens and remains open for 5 minutes, the module board will go into lock out and shut down the blower motor. If this occurs, the thermostat will need to be reset for the furnace to operate.

When the thermostat has reached its set point and the demand for heat ends, the gas valve will be de-energized and the flame will go out. The post purge period of 90 seconds begins. When it times out, the blower motor output is removed, and the blower stops.

Time Line

Start

Thermostat Calls for Heat

Sequence of Operation for 24 VAC Fan Control Module Board

Part Number 520947

Description - Sequence of Events

The wall thermostat controls the operation of the furnace by reacting to room temperature, this allows current to flow through the On/Off switch to the module board.

The module board must have a minimum 18 volts for normal operation.

Upon a call from the thermostat, the module board thermostat circuit will go active. The sail switch circuit is verified as being open. The blower output is energized. Blower motor starts.

31

15 Seconds Purge

Cycle

7 Seconds Ignition

Cycle and Flame

Sense

2 nd and 3 rd Ignition

Cycles if Required

Heating Cycle

The module board will then verify that the sail switch circuit is closed and motor is up to speed. If this circuit remains open blower motor will run continuously until sail switch closes.

The module board checks that the gas valve relay contacts (which are located on the module board) are open before the ignition sequence starts.

The board has a pre-purge timing circuit of (approximately 15 seconds). This allows the chamber to purge.

The module board will energize the gas valve and enable the high voltage spark output to the electrode for 7 seconds of ignition time.

The module board will then check for flame sense to verify successful lighting of the main burner flame. Sparking will then be terminated and the gas valve and blower outputs will remain energized.

If ignition is successful the module board will monitor the flame sense, sail switch and limit switch circuits, and the thermostat inputs during the heating period.

The flame is sensed through the flame sence electrode. Therefore, it is essential that the electrode is properly positioned in the burner flame.

3 Try Ignition Board

If the flame is not sensed after seven (7) seconds, a second 15 second purge cycle will begin followed by a second Trial-For-Ignition sequence. After three (3) Trial-For-

Ignition attempts with no ignition of the main burner, the module board will de-energize the gas valve immediately and blower will run for 90 seconds and then shutdown in lockout.

If during the heating cycle, the limit switch circuit opens and remains open the gas valve will close and the blower motor will continue to run.

90 Second Shut

Down

When the thermostat has reached its set point and the demand for heat ends, the gas valve will be de-energized and the flame will go out. The post purge period of 90 seconds begins. When it times out, the blower motor output is removed, and the blower stops.

Sequence of Operations for SHD-2542

1st Stage Call for Heat

The wall thermostat controls the operation of the dual stage furnace by reacting to room temperature. This allows current to flow through the On/Off switch to the Blower Speed Control Board then to the Module Board.

The module board constantly checks for a minimum 9.5 volts. If there is not 9.5 volts, the module board will go into a standby mode until adequate power is supplied. It will then resume normal operation.

Upon a call from the thermostat the first stage will be activated. The module board thermostat circuit will go active and the sail switch is verified as being open. The blower output is energized. The blower motor starts.

15 Second Purge Cycle

The module board will then verify that the sail switch circuit is closed and motor is up to speed. If this circuit remains open for 30 seconds after the blower motor starts, the module board will go into lockout and shut down the blower motor.

The module board checks that the gas valve relay contacts (located on the module board) are open before the igniting sequence starts.

The board has a pre-purge timing circuit of approximately 15 seconds. This allows the combustion chamber to purge.

7 Second Ignition Cycle and Flame Sense

The module board will energize the gas valve and enable the high voltage spark output to the electrode for a seven second ignition period.

32

The module board will then check for flame sense to verify successful lighting of the main burner flame. Sparking of the igniter is then terminated. The gas valve and blower outputs will remain energized.

If ignition is successful the module board will monitor the flame sense, sail switch, and the limit switch circuits. The flame is sensed through the spark wire and electrode therefore, it is essential that the electrode is properly positioned in the burner flame.

3 try Ignition Board

If the flame is NOT sensed after seven (7) seconds, or if the unit fails to ignite, a second fifteen (15) purge cycle will begin followed by second trial for ignition sequence. After three (3) trial for ignition attempts with no ignition of the main burner, the module board will deenergize the gas valve immediately and the blower will run for three (3) minutes and then go into lockout mode.

2

nd

Stage Heating

If during the thermostat cycle the demand for heat drops below the second stage thermostat setting ( 3 to 5 degrees variance depending on thermostat manufacturer), the blower speed control board will be energized. The blower speed control board will energize the additional gas valve solenoid and increase motor speed to the high position. Furnace will remain in the second stage operation until thermostat is satisfied.

90 Second Shut Down

When the thermostat has reached its set point and the demand for heat ends, the gas valve will be de-energized and the flame will go out. The post combustion purge period of 90 seconds begins. When it times out, the blower motor output is removed, and the blower stops.

Thermostat closes -No<

TROUBLE SHOOTING GUIDE SUBURBAN RV FURNACES with TIME DELAY

Check thermostat wire connections, contact points and the heat anticipator.

12 VDC HEATING SECTION

-Yes-

<

Clean points, secure loose connections, replace thermostat if

Anticipator is shorted.

?

No

Check 12vdc at blue wire, check the amp draw to thermostat.

?

?

-Yes<

Replace thermostat.

Yes No

?

?

-Yes< Repair or replace connections

Check for shorts.

Check components amperage.

or parts with higher than normal amp draw.

?

?

Yes

Check for 12vdc at furnace -No-

<

Check on/off switch on furnace

Yes

?

Check fuse or circuit breaker -No< Replace fuse/Reset breaker

?

Yes

Approximately 10-20 seconds Blower is operating

?

-No<

Check for 12vdc at time delay relay and for

12vdc to red wire leading to the motor.

Yes

?

-No-

<

Replace the time delay relay.

?

Replace the motor.

Check ground wire on terminal block.

Yes -No<

After 15 seconds the module creates spark and opens valve.

?

-No-

<

Check for 12vdc between red and wires at the module board.

yellow

?

Check plug connection to the

-Yes< mModule-electrode and wire-spark gap 1/8 inch between probe and ground.

No

?

33

sail switch.

limit switch.

Spark occurs for approximately

7 seconds and main burner flame establishes.

-No<

? module.

Yes

?

Check for 12vdc at limit switch, both sides.

No

Check for 12vdc at sail switch both sides.

?

No spark at the electrode

Yes

Check for 12vdc at gas solenoid valve.

?

-No-

<

Yes

Did the gas valve open.

?

?

-Yes<

?

-Yes<

Replace the module.

?

-No<

Replace the

Replace the

Replace the pressure at the manifold or for

?

Yes

?

Yes

Check for restriction in combustion air

Intake (wasps, etc.)

No

Is flame established.

?

-No< Check gas restrictions in the burner orifice.

No

? ?

Replace the gas valve.

contact to electrode. Flame should

?

?

-No- be hard blue.

Check flame

Thermostat opens and the time delay operates the fan for the cool down cycle.

Yes

-No-

<

Replace the time delay relay.

System Ok

Thermostat Closes

NOTE: On some models, sail switch is before limit switch.

TROUBLE SHOOTING GUIDE SUBURBAN RV FURNACE with FAN

CONTROL MODULE BOARDS 12 VDC HEATING SECTION

Check thermostat wire connections, Clean points, secure loose

-No-

< anticipator. contact points and the heat anticipator is shorted.

-Yes-

< connections, replace thermostat if

?

No

?

?

-Yes-

<

Replace thermostat.

Yes

?

Check 12vdc at blue wire, check the amp draw to thermostat.

No

?

Check for shorts.

Check components amperage.

-Yes-

<

Repair or replace connections or parts with higher than normal amp draw.

?

?

?

-No<

Yes

Check for 12vdc at furnace

Yes

?

Check fuse or circuit breaker

Yes

?

Check for 12vdc at power terminal on

34

-No<

-No<

-No<

Check on/off switch on furnace

Replace fuse/Reset breaker.

Blower is operating

?

Yes module board and for 12vdc to red wire at call for heat.

Yes

?

Check ground wire on terminal block. -No<

Replace the module board after confirming motor operation. leading to the motor.

Replace the motor.

?

Motor is operating

Yes

?

-No< Reset thermostat. Motor operating. Check for 12 vdc at blue wire on molex edge connector.

-Yes< Verify voltage thru limit and sail switch to module board. If circuit remains open for 30 seconds, module board will go into lockout and shut down motor. Reset thermostat. Replace defective part.

?

?

Yes

?

?

Spark occurs for approximately

7 seconds and main burner flame establishes.

Check plug connection to the creates spark and opens valve.After 15 seconds the module module board. -Yes-

<

-No-

<

Check for 12vdc between red and yellow wires at the module-electrode and wire-spark gap 1/8 inch between probe and ground.

No

?

Check for 12vdc at limit switch, both sides.

No

?

Check for 12vdc at sail switch -Yes<

-Yes< Replace the sail switch.

Replace the limit switch. both sides.

-No< No spark at the electrode -No< Replace the module.

?

?

Yes

-No< Replace the module.

?

Check for 12vdc at gas solenoid valve.

Yes

?

?

?

-No< Check gas pressure at the manifold or for

Did the gas valve open. restrictions in the burner orifice.

No

?

Yes

?

Yes

?

Check for restriction in combustion air Intake (wasps, etc.)

No

?

Replace the gas valve.

?

-No- Check flame contact to electrode. Flame should

Is flame established. be hard blue.

Thermostat opens and the module board cool down cycle.

Yes

-No-

<

operates the fan for the Replace the module board

System Ok

CAUTIONS:

SERVICE HINTS, DIAGNOSIS, AND CORRECTIVE MEASURES

FOR THE IGNITION SYSTEMS OF

SUBURBAN 24 VOLT ELECTRONIC IGNITION GAS FURNACES

WITH TIME DELAY

4. Be sure the electrode assembly screws are snug at all times, especially after the electrode has been removed and reinstalled.

1. Never operate the furnace with the electrode wire disconnected nor with the electrode assembly removed from the furnace.

2. Never use a screwdriver on any part of the electrode assembly while the furnace is in operation.

5. If the module board is found to be defective, it must be replaced - it is not field repairable. Any attempts to repair the board may alter the board and cause it to operate in an unsatisfactory manner.

3. Be certain that the spark from the electrode never reaches the flame sensor portion of the electrode assembly.

6. Insure that the gap between electrode and ground is always 1/8".

The gap between the flame sensor should be approximately twice the gap

35

between electrode and ground to insure no sparking to sensor. Sparking to sensor will damage the module board.

The electronic ignition system is made up of three main parts; the module board, the electrode assembly, and the electrode wire. The module board is the brain of the electronic ignition system and it has several functions.

1. When the blower reaches approximately 75% of the normal r.p.m.and sufficient air flow is established, the sail switch engages and completes a 24 volt circuit through the limit switch to the module board.

2. After a 12 - 18 second delay, 24 volt current will pass through themodule board to the solenoid valve. The current to the valve opens it and allows gas to the main burner; simultaneously, the module board sends high voltage through the electrode wire to the electrode assembly.

The voltage seeks a ground between electrode and ground probe and a spark occurs. The spark then ignites the main burner.

3.

The module board also performs the lockout function in cases where the spark fails to light the burner. When lockout occurs, the spark stops, the voltage from the module board to the gas valve is discontinued, and the valve closes. The unit will remain in lockout and the blower will continue to run until the thermostat is turned off. Turning the thermostat off disengages the lockout function of the module board. After the blower has stopped, the ignition sequence can be started again. The module will try three times for ignition before lockout.

It is important to determine the type problem being experienced, then the proper checkout procedure can be made. The following is a list of problems, how to identify in which area the problem is located, and how to correct it.

1. Electrode not sparking - with blower running and micro switch engaged, check the following: a. Check for proper voltage at module board after the blower motor reaches full r.p.m. If no voltage, check continuity through micro switch and limit switch. Also check wiring and wire connections.

b. Voltage is present but no spark at electrode after 12 - 18 second delay, check electrode wire connections.

c. Wire connections OK, but electrode wire does not show continuity through it - replace electrode wire.

d. Electrode wire does show continuity through it - check electrode gap to be sure it is 1/8" maximum between electrode and ground. NOTE: Gap between sensor and ground must be twice electrode gap.

e. Electrode gap OK - check electrode assembly for possible cracks or carbon on tip of electrode.

f. Electrode OK - replace module board.

2. Electrode sparking, but gas not coming through burner: a. Check to see if voltage is coming out of module board to gas valve after the 12 - 18 second delay. Check the wires in the molex connector to be sure they are intact and making contact with the module board. Check wire from the module board to valve for continuity. Wire and connections check OK - replace module board.

b. Voltage is coming out of module board to gas valve, but gas valve does not open - replace gas valve.

3. Electrode sparking and gas valve opening, but burner will not light: a. Check to see if gas is coming through to the burner. This can be accomplished by using a flow meter in the gas supply line. If no gas is coming through the burner, check for obstruction in gas line, in main burner orifice, or in main burner.

b. Gas is coming through burner, but spark will still not ignite burner - check gas pressure.

Line Pressure - Min. 11" W.C.*, Max. 14" W.C.

To properly check pressure, first determine the line pressure, cycle furnace and check pressure drop on demand. The drop in pressure should not be more than ½" W.C. A drop of more than 1/2" would indicate a faulty regulator, a restriction in the gas line, or a pinched gas line. Excessive pressure drop could also be due to moisture contamination. c. Gas pressure OK - check for obstruction in main burner; check to be sure electrode is positioned approximately 1/4" above and directly over slots on the main burner - adjust electrode if necessary.

d. Remove burner and check burner for obstructions. Clean as required.

4. Burner ignites, but goes off and into lockout: a. Check to be certain that flame sensor is over slots in the main burner and that the main burner flame is burning against the tip of the flame sensor - adjust by bending sensor probe. NOTE:

Sensor probe should be in the inner blue cone of the burner flame (approximately 1/4" t o 5/16" above burner).

b. Burner still goes off and into lockout - check wire connections at flame sensor and at module board.

c. Wire connections OK - check continuity through flame sensor wire.

d. Continuity of flame sensor wire OK - check with micro amp meter in series with flame sensor and flame sensor wire to be certain that the flame sensor is generating at least seven micro amps within seven seconds after the burner is ignited. Connect meter as follows: (+) to sensor wire, (-) to sensor probe. Adjust position of sensor probe, check for carbon deposits on sensor probe if reading is less than seven micro amps.

e. Flame sensor circuit generating at least seven micro amps, but burner still goes off and into lockout - replace module board.

5. Repeated module board failures: a. Check to be certain that the electrode spark is not sparking against the flame sensor portion of the electrode assembly. b. Check to be sure module board or high voltage wires are not shorted to the chamber wrapper or other furnace parts.

c. Be sure insulator covering the electrode wire connection on the coil of the module board is in place and insulator behind module board is in place.

d. Make certain that the transformer voltage is within 24 - 30 volts

A.C. e. Be sure duct connections to furnace are airtight. Seal duct collar connections to furnace cabinet with duct tape, if necessary to prevent hot air leakage. No air leakage should exist anywhere in the duct system, especially at connections on furnace cabinet.

f. Be sure sensor wire terminal is tightly affixed to sensor probe.

g. Be sure high voltage electrode wire is in good condition and properly positioned onto pierce point electrode.

6.

Customer complains of unit going into lockout only once in a while: a. Thoroughly check electrode and burner relationship.

b. Lockout can occur if the gas pressure fluctuates at the time the thermostat calls for heat. Pressure fluctuations can be caused by a malfunctioning gas bottle regulator, an obstruction or a kink in the gas line, or moisture in the gas bottle regulator or in the gas lines. It is difficult to check for these fluctuations that will not noticeably affect any other appliance in the coach. However,

36

isolating the furnace from the coach gas system will determine if the gas system is responsible. This isolation procedure can be done by connecting a separate upright bottle, regulator and gas line directly to the furnace, eliminating the coach gas system. If the occasional lockout still exists, then the furnace should be thoroughly tested to determine the cause; however, if the furnace works properly on this separate system, then the coach gas system should be checked.

c. Check furnace return air and warm air discharge to be certain sufficient air flow is present to engage micro switch every time.

d. Check micro switch to be sure it moves freely.

1. Disconnect gas bottle and drain it completely dry of all gas and all moisture.

2. Disconnect and blow out all gas lines completely dry.

3. Check pressure regulator on the gas bottle. Replace if necessary.

4. Add the drying agent. One half pint of methanol alcohol per

100 pound bottle capacity is recommended.

Precautions:

5. Never fill the gas bottle over 80%.

6. Do not use the gas bottle completely dry to avoid using up the drying agent.

e. Remove electrode and burner. Clean thoroughly.

We have found the above procedures to be effective in solving f. When moisture in the gas system is suspected as being the most occasional lockout problems, especially where the problem, especially where the horizontal type gas bottle is being used, the following steps should be take to prepare the gas system against further moisture problems:

Corrective Measures: horizontal type gas bottle is used. All of these steps must be performed as described for the preparation of a contaminated gas system to be 100% effective.

Figure 21

P-30S with Time Delay

Figure 22

P-40 with Time Delay

37

Figure 23

Remote Flame Sense

With Time Delay

Figure 24

( NT Models )

With Time Delay

38

Figure 25

(SF-20/25/30/35/42F)

Figure 26

Local Flame Sense

(SF Models)

With Time Delay

Figure 27

Fan Control Board

(NT-12/16/20S and SE)

39

Figure 28

Fan Control Board

(NT-24/30/34SP and NT-40)

Figure 29

Fan Control

40

P-30S

Figure 30

Fan Control Board

P-40

41

FURNACE REMOVAL

To replace parts or service the SUBURBAN family of RV furnaces, it is necessary to follow these steps:

DD-17DSI

1. Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.

2. Remove the vent cap assembly by removing applicable screws.

3. Remove the cabinet front two (2) screws.

4. Remove the applicable screws securing the furnace to the coach floor.

5. Remove duct from side of furnace, if equipped.

6. Remove the furnace from the cabinet area to gain access to combustion chamber and applicable parts.

7. Some parts can be accessed without removal of the complete furnace.

8. To re-install, reverse this procedure.

9. Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.

NT-12/16/20S

1. Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.

2. Remove the vent cap assembly by removing applicable screws.

3. Remove the cabinet front two (2) screws.

4. Remove the (1) one tie down screw securing the chamber to the cabinet.

5. Remove the furnace from the cabinet by pulling chamber outward completely to gain access to all controls and applicable parts.

6. To re-install, reverse this procedure.

7. Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.

NT-12/16/20SE

1. Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.

2. Remove the vent cap assembly by removing applicable screws.

3. Remove the cabinet front two (2) screws.

4. Remove the (2) two tie down screws securing the chamber to the cabinet.

5. Remove the furnace from the cabinet by pulling chamber outward completely to gain access to all controls and applicable parts.

6. To re-install, reverse this procedure.

7. Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.

NT-24/30/34SP and NT-40

1. Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.

2. Remove the vent cap assembly by removing applicable screws and one (1) flue retaining screw. Not applicable to NT-40.

3. Remove the cabinet front two (2) screws.

4. Remove the (2) two tie down screws securing the chamber to the cabinet.

5. Remove the furnace from the cabinet by pulling chamber outward completely to gain access to all controls and applicable parts.

6. To re-install, reverse this procedure.

7. Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.

FURNACE REMOVAL

SF-20/25/30/35/42, SFV-20/25/30/35/42, SH-35/42 and SHD-2542

1. Remove the vent cap assembly from the outside access door by removing applicable screws, also the four (4) screws retaining the door to the frame. Remove the door to gain access to the furnace.

2. Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.

3. Remove the (1) one tie down screw securing the chamber to the cabinet.

4. Remove the furnace from the cabinet by pulling chamber outward completely to gain access to all controls and applicable parts.

5. To re-install, reverse this procedure.

42

6. Rewire applicable wires and perform a leak test on all fittings.

Perform a drop pressure test.

SF-20/25/30/35/42F, SFV-20/25/30/35/42F and SH-35/42F

1. Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.

2. Remove the vent cap assembly by removing applicable screws.

3. Remove the cabinet front two (2) screws.

4. Remove the (1) one tie down screw securing the chamber to the cabinet.

5. Remove the furnace from the cabinet by pulling chamber outward completely to gain access to all controls and applicable parts.

6. To re-install, reverse this procedure.

7. Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.

P-30S and P-40

1. Turn off gas and power, then disconnect gas and power supply at the furnace. Label wires as necessary.

2. Remove the vent cap assembly by removing applicable screws and one (1) flue retaining screw. (Not applicable to P40.)

3. Remove the cabinet front two (2) screws.

4. Remove the (2) two tie down screw securing the chamber to the cabinet.

5. Remove the furnace from the cabinet by pulling chamber outward completely to gain access to all controls and applicable parts.

6. To re-install, reverse this procedure.

7. Rewire applicable wires and perform a leak test on all fittings. Perform a drop pressure test.

SF, SH AND SHD-2542 ELECTRODE GAP SPECIFICATIONS AND POSITIONING

To assure consistent ignition of the burner, it is important for the electrode to be positioned properly over the top of the burner. When replacing the electrode, or should you be experiencing ignition type problems, the electrode should be positioned as outlined in the drawing.

1. Remove the furnace chamber assembly from the furnace cabinet following instructions listed in the installation manual.

2. Remove the burner access door. Manifold assembly will have to be removed at the valve. Remove the burner from the combustion chamber by removing six (6) screws which attach the burner to the chamber and air baffles (plates). Remove top air baffle and clip.

3. Locate the lance in relation to the burner ports for electrode positioning by: a. Shine a flashlight into the burner venturi as illustrated (be sure the flashlight lens is against the end of the burner). b. Light will reflect off the lance in the venturi of the burner and shine through a position of the two (2) rows of burner ports in the top of the burner. c. Using a black felt-tip pen, mark a line along top of burner 3/16" from back of lance and parallel with lance. Make an additional mark indication center line of the lance. (See illustration). Both marks will be used later as reference marks; therefore, keep lines thin.

4. Reassemble the burner into the chamber. Be sure the air baffles (plates) are positioned as removed. Mount center clip in place.

5. Adjust electrode so the electrode probe is positioned along the marked center line of the burner lance and the tip of the electrode terminates 3/16" from the back of the lance (at the line marked in Step 3C). (See illustration).

6. IMPORTANT: Be sure electrode probe maintains a 1/8" spark gap over the burner as illustrated.

7. Reinstall burner access door and reconnect manifold. Manifold must be checked for leaks with unit operating, before installing in cabinet. Reinstall furnace into the cabinet following the instructions in the installation manual. Check all gas connections for leaks using proper leak test solution.

43

Figure 31

NT ELECTRODE GAP SPECIFICATIONS AND POSITIONING

To assure consistent ignition of the burner, it is important for the electrode to be positioned properly over the top of the burner. When replacing the electrode, or should you be experiencing ignition type problems, the electrode should be positioned as outlined in the drawing.

1. 1/8" spark gap between electrode and ground.

2. Maintain electrode position of 3/16" over burner ports.

Figure 32

LOCAL FLAME SENSE

PARK MODEL ELECTRODE GAP SPECIFICATIONS AND POSITIONING

To assure consistent ignition of the burner, it is important for the electrode to be positioned properly over the top of the burner. When replacing the electrode, or should you be experiencing ignition type problems, the electrode should be positioned as outlined in the drawing.

44

3.

1.

2.

1/8" spark gap between electrode and ground.

1/4" spark gap between ground and flame sensor.

Maintain electrode position of 3/16" over burner ports.

Figure 33

REMOTE FLAME SENSE

MAINTENANCE

Preventative maintenance is essential if an RV owner is to have reliable, safe operation of his furnace. Two important areas to watch closely in order to assure safe, reliable operation are the venting and the main burner.

An obstruction in the vent or main burner will reduce the combustion air which results in incomplete combustion. Whenever incomplete combustion occurs, the by-products are carbon monoxide (CO) and soot. If the furnace outside exhaust vent shows black soot forming, the furnace should not be operated until the problem is corrected. Two common causes are:

1. Restriction in the vent or furnace intake (screens, wasp nests, tape).

2. Dirty burner.

If operation of the furnace continues under these conditions, it could result in serious injury to the occupants of the RV or even death.

Cleaning of the main burner and an inspection of the venting system should be done at least once a year, preferably just before the beginning of the heating season. Some RV owners and service personnel have the false assumption that if a furnace has not been used, it will not require cleaning. NOT SO!

A furnace which has not been used for some time could be more in need of cleaning than a furnace which has been used extensively.

Dust and lint should be removed from the room air blower wheel and sail switch. A build up of dust and lint on the blower wheel can cause the motor to drag and not generate enough air flow to engage the sail switch. Dust accumulation on the sail switch will restrict the travel of the actuator arm to where the air flow across the paddle will not sail it in and complete the valve circuit.

A yearly inspection should be made of all gaskets on the furnace. If any gaskets show signs of leakage or deterioration, they must be replaced.

Figure 34

45

Figure 35

Figure 36

Figure 37

46

CAUTIONS & SAFETY INFORMATION

1. Never use a battery charger to power or test an electronic ignition furnace as they sometimes provide more than

14.5 DC Volts that could damage the module board.

2. Never operate the furnace with the electrode wire disconnected nor with the electrode assembly removed from the furnace.

3. Never use a screwdriver on any part of the electrode assembly while the furnace is in operation.

4. Be certain that the spark from the electrode never reaches the flame sensor portion of the electrode assembly on remote sense units.

5. Install the furnace so electrical components and connections are protected from water.

6. Wire the furnace direct to the battery when possible.

7. Use two wrenches on gas fittings when tightening gas connections.

8. Verify voltage of furnace, do not use 120 volt AC with 12 volt DC.

9. Do not modify the furnace in any way.

10. Do not vent the furnace to an outside enclosed porch area or where the vent is covered or obstructed.

11. Always meet or exceed minimum duct requirements. Also meet the minimum return air requirements.

12. Furnace must be installed and vented correctly. Refer to the Installation Manual for the specific model furnace.

13. Do not install aftermarket components.

SUBURBAN MANUFACTURING COMPANY

676 Broadway Street

Dayton, Tennessee 37321

423-775-2131

Fax: 423-775-7015 www.rvcomfort.com

E-mail: [email protected]

2007