BEA MULTI-SENSOR HUB User Guide
BEA MULTI-SENSOR HUB is a device designed to connect up to 4 sensors to a single door/window controller. It allows for monitoring the status of the connected sensors, either asynchronously (independently of the door controller) or synchronously (when the door controller sends a monitoring request). The monitoring cycle time can be set to 10 minutes or 20 seconds in asynchronous mode. The device features 2 galvanically isolated outputs for connection to the door controller, 1 galvanically isolated input for monitoring the door controller's status, and 4 non-isolated inputs for connecting the sensors.
Reklama
Reklama
MULTI-SENSOR HUB
Hub for connecting multiple protective sensors to one automated door/window controller
DESCRIPTION
Output 1: Green LED
Output 2: Red LED
Door controller connector
DIP-switches
1 + 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
Input 1: Green LED
Input 2: Red LED
Sensor connectors
Yellow LED
Confirmation push button
LED SIGNAL
GREEN
ON
Output 1
Input 1
RED
ON
Output 2
Input 2
LED switches ON during detection
Active mode
LED switches OFF during detection
Passive mode
YELLOW flashing
Awaiting confirmation
DIP-switch setting
TECHNICAL SPECIFICATIONS
Max. load current:
Supply voltage:
Output to door controller:
2 A
12 V DC - 24 V DC +10% (min. 16 V DC @ max. load current)
Monitoring input from door controller:
Input from each sensor:
Monitoring output to each sensor:
Monitoring response time:
LEDs:
Applicable to :
Conformity:
Temperature range:
Dimensions:
Housing material:
Length of sensor cables:
Length of power cable:
Lifetime: maximum output power dissipation: 200 mW off-state leakage current: 10 µA on-state maximum resistance: 20 Ohms
1 galvanical isolated input (Optocoupler; max 30 V DC (6 mA)); voltage threshold: logic high: >10 V DC (2 mA); logic low: <1 V DC
2 non-isolated inputs
1 non-isolated output (U = U from 200µs to 50ms (depending on sensors & hub setting) red & green for status display of each connected sensor red & green for hub output status display orange for DIP-switch status change display
IXIO-DT1, IXIO-ST, Flatscan SW, Flatscan W, 4Safe
EN ISO 13849-1 Pl"c"/CAT2 from -25° to +60° (for indoor use only)
70 mm (L) x 55 mm (H) x 25 mm (D)
ABS (translucent blue)
2.70 m
2.60 m designed for minimum 10 years
Specifications are subject to changes without prior notice.
For more information concerning the monitoring cycle, see application note on monitoring by voltage.
1/2
WIRING
2.
ON
1 2 3 4 5 6 7 8 9 10
1.
MULTI-SENSOR HUB
OUTPUT 1
OUTPUT 2
GREEN
BROWN
YELLOW
WHITE
GREY
PINK
RED
BLUE
DOOR CONTROLLER
24V DC
GND
IN 1
IN 1
IN 2
IN 2
TEST +
TEST -
1. Connect the sensors (from 1 to 4) to the sensor connectors starting from the left using the cables that have connectors on both ends.
Attention! Never use the 4SAFE power cable to connect the Hub to the door controller.
2. Connect the cable with only one connector from the Hub to the door controller (see wiring diagram).
DIP-SWITCH SETTINGS
DIP1 Number of sensors connected to the Hub
DIP2
ON
1 2
3 4 5 6 7 8 9 10
1 sensor
DIP3 Tested Output(s)
ON
1 2
3 4 5 6 7 8 9 10
2 sensors
ON
OFF
R1 & R2
R2
(e.g. Flatscan SW, 4SAFE)
(e.g. IXIO, Flatscan W)
ON
1 2
3 4 5 6 7 8 9 10
3 sensors
ON
1 2
3 4 5 6 7 8 9 10
4 sensors
The selected test mode is applicable for all connected sensors.
Do not mix sensor types.
DIP4 Logic R1
(Output configuration)
NC
OFF NO
Check the output logic on the connected sensors.
The output logic has to be the same on the Hub and on all connected sensors (see LED-signal).
DIP5 Logic R2
(Output configuration)
OFF
NC
NO
DIP6
Relay debounce avoids the bouncing of the relay contact during a monitoring request
DIP7
Monitoring mode
The monitoring has to be active on all connected sensors!
DIP8
Monitoring cycle time in asynchronous mode
OFF
10 min
20 sec
DIP9
Monitoring type
OFF
ON
OFF
OFF
Asynchronous
Synchronous
OFF
Standard voltage monitoring
Signal output
100 Hz
Check the output logic on the connected sensors.
The output logic has to be the same on the Hub and on all connected sensors (see LED-signal).
Recommended when the monitoring input is connected to a relay output on the door controller.
Set to OFF for a faster response time.
The Hub sends a monitoring request to all connected sensors every x seconds (according to DIP 8 setting), independent of the door controller.
When the door controller sends a monitoring request to the Hub, it answers immediately giving the result of the last monitoring cycle.
The Hub sends a monitoring request to all connected sensors only when the door controller sends a monitoring request to the Hub. The response time on monitoring request is dependent on response time of the connected sensors.
The Hub sends a monitoring request to all connected sensors every 10 minutes (only in asynchronous mode).
The Hub sends a monitoring request to all connected sensors every 20 seconds (only in asynchronous mode).
Most frequently used type of monitoring using test input.
Only if your door controller is compatible with this type of monitoring.
DIP10
Not used
YELLOW OFF
After changing one or more DIP-switch settings, the yellow
LED flashes. Confirm the new setting(s) by pushing the push button until the LED switches off. The setting is confirmed.
Manufactured by BEA SA - LIEGE Science Park - Allée des Noisetiers 5 - B-4031 Angleur - T +32 4 361 65 65 - F +32 4 361 28 58 - [email protected] - www.bea.be