Schmersal NAS 311 ST1-AS Emergency stop switch Operating Instructions
Schmersal NAS 311 ST1-AS is an emergency stop station designed to enhance the safety of your machinery and ensure compliance with industry standards. It features an AS-Interface module that detects safety-relevant switching conditions of mechanical contacts and transmits a unique safety code over the AS-i network for monitoring by the ASM safety monitor.
This emergency stop station boasts a robust construction with an IP65 protection class, making it suitable for use in harsh industrial environments. Its compact design allows for flexible installation in various applications, providing easy access in case of emergencies.
Oglas
Oglas
Operating instructions
Emergency stop Station NAS 311 AS
8 EU Declaration of conformity
EN Operating instructions. . . . . . . . . . . . .pages 1 to 6
Original
Content
1.2
Target group: authorised qualified personnel . . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5
Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3.3 Dimensions of the NAS 311 AS M emergency stop station . . . . . . .3
4 Rear side Electrical connection
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 Programming the slave address . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2
Configuration of the safety monitor . . . . . . . . . . . . . . . . . . . . . . . . .3
5.3 Status signal "safety release" . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.4 Diagnostic functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
1. About this document
1.1 Function
This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety switchgear. the operating instructions must be available in a legible condition and a complete version in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only.
Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation.
The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution:
Warning:
Failure to comply with this warning notice could lead to failures or malfunctions.
Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating instructions manual, the country specific installation standards as well as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net.
The information contained in this operating instructions manual is provided without liability and is subject to technical modifications.
EN 1
2
Operating instructions
Emergency stop Station
If multiple safety components are wired in series, the Performance Level to EN ISO 13849-1 will be reduced due to the restricted error detection under certain circumstances. The entire concept of the control system, in which the safety component is integrated, must be validated to EN ISO 13849-2.
There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed.
1.6 Warning about misuse
In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded. The relevant requirements of the standard EN 1088 must be observed.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
NAS 311 ➀ -AS
No. Option
➁
Description
➀ ST1
➁
M
MH
M12 connector, plastic
Thermoplastic enclosure
Metal enclosure and metal button plus metal collar
Only if the information described in this operating instructions manual are realised correctly, the safety function and therefore the compliance with the Machinery Directive is maintained.
2.2 Special versions
For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version.
2.3 Purpose
The emergency stop station of the series NAS 311 AS is used on machinery and plants as a safe command device to generate a safe signal initiating the shutdown of a hazardous movement when actuated.
The NAS 311 AS must only be used in combination with the AS-i ASM safety monitor.
The integrated AS-i module is used to detect safety-relevant switching conditions of mechanical contacts.
An AS-Interface Safety at Work component functions on the basis of an individual code generator (8 x 4 bit). This safety code is cyclically transmitted over the AS-i network and monitored by the ASM safety monitor.
NAS 311 AS
The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level.
Maintenance: Please observe that the safety function must be triggered at least once a year to test the system!
2.4 Technical data
Standards:
Enclosure:
Mechanical life:
Connection:
Switching frequency f:
Response time:
EN 60947-5-1, EN ISO 13850,
EN ISO 13849-1, IEC 61508, EN 50295 glass-fibre reinforced polyamide, self-extinguishing (to UL-94-V-0)
M / MH: light metal
≥ 100.000 operations
M12 connector, 4 pole
≤ 1 Hz
< 100 ms
Electrical data - AS-Interface:
AS-i supply voltage: 26.5 ... 31.6 VDC, through AS-Interface, reverse polarity-proof (stabilised PELV unit)
AS-I power consumption:
AS-i specification:
≤ 50 mA
Version: V 2.1
Profile: S-7.B.0.E
IO code: 0x7
ID code: 0xB
ID code 1: 0x0
ID code 2: 0xE
AS-interface inputs:
- Channel 1:
- Channel 2:
AS-interface outputs:
DI 0 / DI 1 = dynamic code transmission
DI 2 / DI 3 = dynamic code transmission
DO 0 … DO 3: no function
P 0 ... P 3 not used AS-Interface parameter port:
Input module address: 0, preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Ambient conditions:
Protection class:
Ambient temperature:
Storage and transport temperature:
Relative humidity:
IP65
−25 °C ... +60 °C
−25 °C ... +85 °C
30 … 95%, no condensation, no icing
2.5 Safety classification
Standards:
PL:
Control category:
PFH-value:
SIL:
Service life:
EN ISO 13849-1, IEC 61508
≤ 1.4 x 10 -8 up to e up to 4
/h up to max.
5,000 switching cycles/year up to 3
20 years
3. Mounting
3.1 General mounting instructions
The devices are supplied in a completely fitted and wired condition. To fix the enclosure, the cover must be removed after the 4 screws have been unscrewed. On the inside, 4 mounting holes are provided for M4 screws (plastic enclosure) or M5 screws (metal enclosure).
The emergency stop station must be smoothly accessible in case of emergency. The emergency stop station can be used and fitted in any position.
EN
Operating instructions
Emergency stop Station
3.2 Dimensions
All measurements in mm.
Dimensions of the NAS 311 AS emergency stop station
85
M
M12
M12
97,8
37,8
3.3 Dimensions of the NAS 311 AS M emergency stop station
60 20
26 8,2
14 29
Dimensions of the NAS 311 AS MH emergency stop station
5 22
M
85
29
4. Rear side Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by authorised personnel in a de-energised condition.
The NAS 311 AS emergency stop station is supplied from the AS-
Interface cable.
The connection to the AS-Interface system is realised through an M12 connector. The wiring configuration of the M12 connector is defined as follows (to EN 50295): spare
4 3
AS-Interface - (blue)
AS-Interface + (brown)
1
2 spare
5. Functions and configuration
5.1 Programming the slave address
The slave address is programmed through the M12 connector. Any address from 1 to 31 can be set by means of the AS-i bus master or a hand-held programming device.
NAS 311 AS
5.2 Configuration of the safety monitor
The NAS 311 AS emergency stop station must be configured in the
ASIMON configuration software with the following monitoring devices.
(also refer to the ASIMON manual)
Double channel forced
• Optionally with startup test
• Optional with local acknowledge
The configuration of the safety monitor must be tested and confirmed by a qualified and authorised safety expert/safety engineer.
5.3 Status signal "safety release"
The "safety release" status signal from a Safety at Work slave can be cyclically queried by the control system through the AS-i master. To that effect, the 4 input bits with the varying SaW code of a Safety at
Work slave are evaluated through an OR operation with 4 inputs in the control system.
5.4 Diagnostic functions
LED indications (internal)
The LED on the internal AS-i module have the following meaning:
LED green (PWR): AS-Interface supply voltage
LED red (FAULT): AS-Interface communication error or slave address = 0 or periphery error
LED yellow (S-I1): Contact 1
LED yellow (S-I2): Contact 2
6. Set-up and maintenance
6.1 Functional testing
The safety function of the safety components must be tested. The following conditions must be checked and met:
• Correct fixing of the fitted component.
• Check the integrity of the cable entry and connections.
• Check the emergency stop station for damage.
6.2 Maintenance
The function of the emergency stop station must be tested in regular intervals.
Maintenance: Please observe that the safety function must be triggered at least once a year to test the system!
Damaged or defective components must be replaced.
7. Disassembly and disposal
7.1 Disassembly
The safety switchgear must be disassembled in a de-energised condition only.
7.2 Disposal
The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations.
EN 3
Operating instructions
Emergency stop Station
8. EU Declaration of conformity
EU Declaration of conformity
Original K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Name of the component: NAS 311 AS
See ordering code Type:
Description of the component:
Relevant Directives:
Emergency stop station with integrated AS-i Safety at Work
Machinery Directive
EMC-Directive
RoHS-Directive
2006/42/EC
2014/30/EU
2011/65/EU
Applied standards: DIN EN 60947-5-1:2010,
DIN EN 60947-5-5:2015,
DIN EN ISO 13849-1:2016,
EN 62061:2005 + A2:2015
Person authorised for the compilation of the technical documentation:
Oliver Wacker
Möddinghofe 30
42279 Wuppertal
Place and date of issue: Wuppertal, November 17, 2017
NAS 311 AS
Authorised signature
Philip Schmersal
Managing Director
The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net.
K. A. Schmersal GmbH & Co. KG
Möddinghofe 30, D - 42279 Wuppertal
Postfach 24 02 63, D - 42232 Wuppertal
Phone: +49 - (0)2 02 - 64 74 - 0
Telefax: +49 - (0)2 02 - 64 74 - 1 00
E-Mail: [email protected]
Internet: http://www.schmersal.com
4 EN