Remko PG12E User Manual
Remko PG12
The Remko PG12 is a powerful and versatile heating device that is perfect for a variety of applications. With its high heat output and efficient design, the PG12 can quickly and easily heat up even the largest rooms. The PG12 is also very easy to use, with simple controls and a clear display.
Some of the key features of the Remko PG12 include:
- High heat output of 12 kW
- Efficient design with a low fuel consumption
- Easy to use controls with a clear display
- Automatic ignition and flame monitoring for safety and convenience
The Remko PG12 is ideal for use in a variety of applications, including:
Reklama
Reklama
#
!
"
%
Make sure to read these instructions carefully before starting/using the unit!
Our guarantee will become void when the unit supplied by us is used and installed for inadequate purposes, or maintained incorrectly, etc., or if it is changed without our prior consent.
!
$ !
Safety Hints
General Hints
Starting
Putting out of Service
Maintenance
Seite
4
5
5 –6
6
7
$ !
Block Diagram
Technical Data
Action in Case of Faults
Drawing
List of Spare Parts
Seite
10
11
8
8
9
Always keep these operating instructions near or on the device!
3
4
# & "
When using this unit make sure always to observe the applicable building and fire protection regulations as well as the rules of the trade cooperative association.
The unit may be operated only by those persons who have been instructed accordingly.
The unit is to be installed and operated in such a way as to ensure that the employees are not endangered by waste gases and radiation heat and that no fire can break out.
The unit may only be installed and operated in rooms, when the air rate fed to the unit is sufficient for combustion.
Make sure to install mobile liquid gas reservoir on a solid ground and in a vertical position.
Liquid gas reservoir may never be used in a lying position while the unit is operating (gas leakage in the liquid phase).
The unit may be operated only in well aerated rooms. Persons may not stay permanently in the room where the unit has been installed. Relevant prohibition signs are to be fastened to the entrances.
The unit is to be installed and operated on a solid non combustible ground.
It is to be ensured that no combustible objects/ materials can be sucked in.
The unit may not be installed or operated in inflammable and explosive surroundings.
A safety zone of 1.5 m around the unit and a minimum distance of 3 m at the unit’s exhaust opening are to be observed, even regarding non combustible objects.
The unit’s exhaust opening may not be reduced or equipped with hoses or pipings.
Make sure not to introduce foreign matters into the unit.
The air suction lattice is always to be kept free from dirt and loose objects.
Make sure not to expose the unit to direct water jets.
All electric cables outside the unit are to be protected from damage (e.g. caused by animals, etc.).
Make sure to cut off the gas supply and to pull the mains plug out of the mains socket when maintenance and repairs are carried out.
Safety devices may be neither overbridged nor blocked.
!
The unit may be operated only by those persons who have been instructed regarding the unit’s operation and the handling of liquid gas.
When using the unit make sure always to observe the guiding principles of the countries and states concerned.
The unit may only be operated in rooms when
– the air rate fed to the unit is sufficient for com-
bustion and
– the rooms are well ventilated and deventilated
and
– the percentage of the substances which are
injurious to health in the breathed in air has
no inadmissible concentration.
A good and natural ventilation and deventilation is given if e.g. the room volume in m³ corresponds to at least 30 times the nominal heat load in kW of all the units being operated in the room, and if a natural air exchange through doors and windows is ensured, or if there are permanently open ventilation possibilities for ingoing and outgoing air near the ceiling and the floor, of which the size in m² corresponds to at least 0.003 times the nominal heat load in kW of all the units being operated in the room.
A uniform unit connection pressure of 0.3 bar (300 mbar) of category I
3B/P is necessary for all countries of the European Community.
The connection pressure may not fall below or
exceed the required value.
Make sure to use exclusively components, such as gas hose, pressure controller and hose security devices (protection against breakage) or safety devices against gas leakage, that have been tested and are suitable for the intended purpose. The pressure controllers must have a firmly regulated initial pressure of
300 mbar and are to be equipped with a security device against hose breakage.
Hose pipes are to be protected generally against chemical, thermal and mechanical damage.
The persons charged with the operation of the unit have to check it prior to starting work to make sure that there are no visible defects. If there are defects which affect the unit’s operational reliability, its operation is to be stopped!
The unit may be only maintained by trained persons and only original spare parts may be used.
If the unit has been switched off by the temperature limiter due to overheating, the reason for the fault has to be detected and eliminated.
#
Make sure to charge a person with the operation of the unit and with the supervision of the reservoirs and of the bottle stock who has been instructed sufficiently regarding the handlings concerned.
The persons charged with the operation of the units have to check the units before starting work to detect obvious defects on the operating and safety elements and to make sure that the safety devices have not been removed.
Make sure to draw the operators‘ attention to possible dangers during the handling of liquid gas.
Important Installation Hint
When installing or removing the gas hose make sure to exert a counterpressure on the gas connection nipple of the unit using an open-end spanner SW 19 and observing the left-handed thread.
1) Unscrew gas hose
Turn union nut clockwise
A constant unit connection pressure of
0.3 bar (300 mbar) must be ensured, also during continuous operation.
2) Fasten gas hose
Turn union nut anti-clockwise
Connect pressure controller to the gas bottle(s).
Attention! left-handed thread!
Open bottle valve(s).
When gas is taken out of several gas bottles simultaneously, all the valves have to be opened.
This procedure also refers to all further gas components, such as pressure controller, hose security device
(protection against breakage), etc.
When any work is carried out on the gas supply line and when the gas cylinder is replaced, all stop valves must be closed and there may be no ignition sources in the direct surroundings.
Press release button of the hose security device (protection against breakage) pened after having othe valve(s).
This has also to be done after each replacement of bottles.
After the installation and connection of the units all the gas bearing connections have to be checked with soap solution, leakage detecting spray etc. to make sure that they are tight.
Do not use open flames!
Hint!
Insufficiently dimensioned supply plants can cause icing of the pressure gas or pressure reservoirs. When the gas pressure falls a proper gas supply to the consumer points can no longer be ensured in many cases.
This will result in imperfect combustion, harmful waste gases or extinction of the flame. Therefore the supply plant is to be dimensioned in such a way as to ensure that problems of this kind cannot be caused.
The cristalline white frost may not be removed by open fire, glowing objects or radiators. Sufficient gas supply to the consumer points can be ensured by using an evaporator.
Sufficient gas supply is to be ensured according to the unit power rating (see identification plate), service life and ambient temperature of the supply tanks.
In principle, we recommend that you use a set of at least 3 cylinders to avoid intensive icing of the reservoirs.
The number of cylinders can be increased by using a set of several cylinders (accessories), depending on the unit capacity and the service life.
Install only in well ventilated rooms, not in rooms which people will be using for longer periods!
5
6
Assembly of Multi-bottle Set
To avoid intensive icing of the gas bottle during a longer operation of the unit, we recommend that you use a bottle battery consisting of at least 3 bottles. All bottle valves must be open to ensure regular gas supply!
2 Press down pin (2) of thermoelectric gas valve (safety pilot).
gas hose to unit hose-break protection pressure controller high pressure hose 0.4 m
T-connection
3
After approx. 2 or 3 sec. the piezo igniter (3) is to be actuated (possibly several times) with the pin (2) still held down, until a formation of flames has occured.
Important!
Make sure to place gas reservoir only laterally behind the unit! Never heat up or defrost gas reservoir through the unit’s hot air current ( danger of explosion!
).
Never use gas reservoir in a lying position when the unit is operating (gas leakage in the liquid phase).
After the formation of flames still hold down the pin (2) for approx. 10 - 15 seconds, until the thermoelectric flame monitoring has started.
Do not release the pin before this.
If the flame is extinguished after the pin has been released, repeat the ignition procedure after having waited for approx. 1 minute. Then keep the pin pressed down a little longer.
Important Hints!
Make sure that the supply air can be freely sucked and the heated air can be blown off without problems.
The suction and blower apertures of the unit may not be narrowed or equipped with hoses or conduits.
Make sure to keep the safety distance from combustible and inflammable materials and to observe the local fire protection codes.
1
1
Put the operating switch into position "O"(= Off) and plug the mains into an appropriate mains socket with fault current safety switch (230V/1~ 50 Hz).
'
The electric connection of the unit is to be carried out according to the VDE 0100 regulations
§ 55, via a special supply point with fault current safety switch.
# % ( )
Put the operating switch into "I" position (= heating operation)
The supply air fan starts.
1
Close all the bottle valves.
Let flame burn out.
The fan should still run for a few seconds to exhaust the accumulated heat.
Put operating switch (1) into “0” position (= off) and unplug mains plug from the mains socket.
Depending on the operation conditions the units are to be tested by an expert when necessary, but at least regularly every two years, to ensure their safe operation.
The test result is to be recorded in a test certificate which is to be safely kept until the next test so that it can be presented to the authorized persons for control purposes at any time.
If any faults are stated the supervisor is to be informed.
If the faults affect the unit’s operational reliability, operation is to be stopped!
Regular maintenance and care, at least after each heating period is the basic condition for a long service life and a faultless operation of the unit.
Make sure to keep the unit free from dust and other deposits and to clean it only with a dry or humid cloth
(do not use water jet).
Do not use sharp or solvent-containing cleaning agents.
Check suction and blowing out lattice regularly to see whether it is dirty and clean it, when necessary.
Check the suction opening for combustion air as well as the injector fitted behind it and the gas nozzle regularly to make sure that they are not dirty.
Check gas hoses and sealings to see whether they are damaged and replace when necessary.
Clean gas burner and gas nozzle regularly.
Clean baffle plate regularly.
Check ignition electrode and set when necessary.
Check thermocouple and clean when necessary
The bi-metal spring may neither be damaged nor bent in or order not to affect the function of the temperature-limiter!
Disassembly for Cleaning
When the unit is being maintained, set or repaired, the gas supply has to be cut off and the mains plug has to be unplugged from the mains socket!
Setting and maintenance work is to be carried out only by authorized specialists!
2
1
1.
Demount 4 fastening screws (1) and pull off outside casing to the. front
2.
Demount 3 fastening screws (2) of air suction grille.
3.
Demount air suction grille with fan motor and fan blade and pull inner casing to the front. ignition electrode thermocouple
3 mm
Intensive yellowish flames indicate that the fresh air supply is probably insufficient and that there is some dirt inside the unit, respectively.
gasburner temperature limiter
Cleaning
After disassemly all components are easily accessible for cleaning and maintenance purposes.
Clean burner using compressed air.
Clean gas nozzle carefully when necessary.
Carefully remove dirt and dust from ignition electrode, thermocouple and temperature limiter.
Remove deposits and other dirt from base of device.
Assemble all the parts thoroughly in reverse order.
Control the functions of the complete unit and carry out a tightness check for all gas-bearing connections using soap solution and leakage detection spray, respectively.
7
! * ( +
KL
1
1
2
2
3
3
4
4
BS
MV2
M
1~
PZ
Z
MV1
TE
TB
PE N L1
KL – terminal strip
BS = operating switch
MV2 = gas valve 2
M = fan motor
Z = ignition electrode
PZ = piezo igniter
TE = thermocouple
MV1 = gas valve (thermoelectric)
TB = temperature limiter
! (
Series PG 12
Nominal heat output
Heating capacity
Air output
Fuel/type of gas
Gas pressure
Gas consumption
Electrical connection kW kW
12
12
0,95
230
50
60
10
44
57
6,8
400
185
320 m³/h 250 liquified gas Cat. I
3B/P
{AT, BE, CH, DE, DK, FR, IT, LU, NL, NO, SE } mbar 300
Frequency
Power consumption max.
Fuse protection
Kind of protection
Sound pressure level L pA
1m 1)
Weight
Dimensions total length kg/h
V
Hz
W
A
IP dB(A) kg mm width height mm mm
1) noise measuring DIN 45635-01-Kl3 in heating operation
Any operation/handling which does not correspond to that indicated in these instructions is prohibited, otherwise we will not be responsible and the guarantee will become void.
The orderer or the customer must have properly filled out the “guarantee certificate” which is enclosed with every
REMKO automatic heater and must have returned it to REMKO GmbH & Co. KG within a timely acceptable period based on the sale and commissioning, to be entitled to possible guarantee claims regarding faulty material.
8
, & . %!
trouble:
– unit doesn’t start
– unit stops during operation
– fan blows, but gas supply is blocked
resp. no ignition
– flame goes out after having released the pin of
thermoelectric gas valve
– gas supply is blocked, resp. flame goes out
– fuel consumption is too high
– unit can’t be shut down
– heating capacity drops during continuous operation
1 – 2 – 3 – 4 – 7
2 – 4 – 7 – 12 – 13
4 – 5 – 8 – 9 – 12
8 – 10 – 11
4 – 6 – 7 –10 – 11 – 12 – 13
12 – 15
3 – 14
13 cause:
1. no electrical connection
3. operating switch defect cause:
4. no gas pressure on solenoid valve
5. no ignition spark
6. air-suction grille impurified
7. unit is shut down by safety thermostat (STB)
8. safety pilot does not open (resp. does not lock)
9. piezo igniter defect
10. thermocouple resp. temperature limiter defect remedy:
- plug the mains into an appropriate mains socket (230V/1~ 50Hz)
- check fan motor, fan blade and clutch plate and replace if necessary.
- close gas supply, unplug the mains and replace defect operating switch
- check gas supply
- check contents of gas cylinders
- check gas hose(s) for damage
- release hose break protection resp. replace it
- set ignition electrode
- check ignition cable
- check porcelain insulation of ignition electrode
- clean air-suction grille
- check air-suction and blow-out grille and clean if necessary
- check fresh air supply
- release safety thermostat (STB - Reset)
- replace safety pilot
- replace piezo igniter
- check position of thermocouple and adjust according to setting hints
- check connection and clean if necessary
14. solenoid valve does not open
- mount original pressure controller
- release hose break protection resp. replace it
- replace empty gas cylinder(s) and connect 2-3 cylinders using multi cylinder set (EDV-No. 1014050)
- close gas supply
- let flame burn out
- put operating switch in position „0” and unplug the mains
- replace solenoid valve
15. leak gas hose(s) - find leakage by foam forming mediums eleminate leakage
Make sure that the gas supply has been closed and the mains plug has been taken out of the mains socket before carrying out any work regarding the unit!
Setting and maintenance is to be carried out by authorized experts only!
9
1
2
30
29 28 27
26
18
17
16
19
14
20
21
25
22
23
24
16
15
14 13
4
8
6
7
5
12
11
We reserve the right to make modifications in dimensions and construction in the interests of technical progress.
9
10
10
3
&
Fig.No. Description
PG 12
EDV-Nr.
17
18
19
20
13
14
15
16
9
10
11
12
7
8
5
6
25
26
27
28
21
22
23
24
1
2
3
4 transport handle outside casing inside casing retaining ring blow out protection grille
Gas burner ignition electrode terminal strip, 4er base foot rest traction relief connecting cable with plug operating switch ignition cable piezo igniter thermocouple gas connection nipple thermoelectric gas valve reducing nipple solenoid valve gas nozzle angled coupling protection socket, small cover plate temperature limiter fan blade clutch plate fan motor
1101142
1103801
1103802
1103811
1103803
1103804
1103818
1101442
1103805
1103806
1103904
1103808
1103809
1103810
1101364
1103812
1103813
1101169
1103829
1101376
1103815
1103816
1101304
1103828
1103817
1103819
1108455
1103820
29
30 air suction grille clutch disk o. Abb. pressure controller with hose-break protection
1103821
1101375
1103825
1,5 running metres gas hose 1103826
2,0 running metres gas hose (HD for building sites) 1103827
W h e n o r d e r i n g s p a r e p a r t s i t i s n e c e s s a r y t o i n d i c a t e
E D V - N o . a n d m a c h i n e n o . ( s e e d a t a p l a t e ) !
11