Ozito MACP-015 6L 1.5HP Air Compressor Kit Product Manual
Ozito MACP-015 is a versatile and powerful air compressor, perfect for a variety of inflation and cleaning tasks. With a 6-liter tank capacity, it can deliver up to 56.4 L/min of free air, making it ideal for inflating tires, balls, and other inflatables. It also features an adjustable pressure regulator, so you can set the perfect pressure for your specific needs. The MACP-015 also comes with a variety of accessories, including a blow gun, inflation adapters, and a tire chuck, making it a great choice for a variety of tasks around the home and garage.
Reklamë
Reklamë
STANDARD EQUIPMENT
AIR COMPRESSOR
KIT
6LITRE 1.5HP
INSTRUCTION MANUAL
SPECIFICATIONS
Power supply: 220–240V ~ 50Hz
Motor:
Tank Capacity:
1200W (1.5HP)
6L
No Load Speed: 3,450/min
Max. Pressure: 8bar (116psi)
Max. Air-Intake Volume: 180 L/min
Free Air Delivary (FAD): 56.4 L/min
IP Rating: IP20
Weight: 11.5kg
ozito.com.au
Air Compressor
Air Gun
6.3m Air Hose
Inflation Adapters x 8
Connection
Accessories x 10
MACP-015
WARRANTY
IN ORDER TO MAKE A CLAIM UNDER THIS
WARRANTY YOU MUST RETURN THE PRODUCT
TO YOUR NEAREST BUNNINGS WAREHOUSE WITH
YOUR BUNNINGS REGISTER RECEIPT. PRIOR TO
RETURNING YOUR PRODUCT FOR WARRANTY
PLEASE TELEPHONE OUR CUSTOMER SERVICE
HELPLINE:
Australia 1800 069 486
New Zealand 0508 069 486
TO ENSURE A SPEEDY RESPONSE PLEASE
HAVE THE MODEL NUMBER AND DATE OF
PURCHASE AVAILABLE. A CUSTOMER SERVICE
REPRESENTATIVE WILL TAKE YOUR CALL
AND ANSWER ANY QUESTIONS YOU MAY
HAVE RELATING TO THE WARRANTY POLICY
OR PROCEDURE.
The benefits provided under this warranty are in addition to other rights and remedies which are available to you at law.
Our goods come with guarantees that cannot be excluded at law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Generally you will be responsible for all costs associated with a claim under this warranty, however, where you have suffered any additional direct loss as a result of a defective product you may be able to claim such expenses by contacting our customer service helpline above.
3 YEAR REPLACEMENT WARRANTY
Your product is guaranteed for a period of 36 months from the original date of purchase.
If a product is defective it will be replaced in accordance with the terms of this warranty.
Warranty excludes consumable parts, for example: valve adapters and accessories.
WARNING
The following actions will result in the warranty being void.
• If the tool has been operated on a supply voltage other than that specified on the tool.
• If the tool shows signs of damage or defects caused by or resulting from abuse, accidents or alterations.
• Failure to perform maintenance as set out within the instruction manual.
• If the tool is disassembled or tampered with in any way.
• Professional, industrial or high frequency use.
OZITO
Australia/New Zealand (Head Office) 1-23 Letcon Drive, Bangholme, Victoria, Australia 3175.
0720
KNOW YOUR PRODUCT
AIR COMPRESSOR
1 Pressure Gauge
2 Carry Handle
3 Nitto Style Coupling
4 Pressure Adjustment Dial
1
5 Drain Valve
6 Safety Release Valve
7 On/Off Switch
2
SETUP & PREPARATION
1. ASSEMBLY AND STARTING
Pre Setup Checks
• Examine the machine for signs of transit damage. If damaged, do not use, return to place of purchase
• The compressor should be set up near to the user.
• Avoid long air lines and long supply lines (extensions).
• Make sure the intake air is dry and dust-free.
• Do not set up the compressor in damp or wet rooms.
• The compressor is designed to be used in dry rooms. It is prohibited to use the compressor in areas where work is conducted with sprayed water. Before you use the machine, make sure that the mains voltage complies with the specifications on the rating plate.
Connecting Air Hose to the Compressor
1 Attach the 1/4” female nitto quick plug to the air hose. Use pipe tape on all threads to ensure a good air seal.
3 4
ACCESSORIES
8 Air Hose (6.3m)
9 Blow Gun
10 Inflation Adapters x 8
8
5 6
11 Connection
Accessories x 10
9
7
2 Insert the 1/4” male nitto quick plug of the air hose into the quicklock coupling of the air compressor by pulling back the sleeve and inserting the plug.
3 The quick-lock sleeve will spring forward automatically, connecting the air hose.
10
ONLINE MANUAL
Scan this QR Code with your mobile device to take you to the online manual.
11
OPERATION
Connecting to the Compressed Air Hose
WARNING! BEFORE CONNECTING OR
DISCONNECTING ACCESSORIES, ALWAYS MAKE
SURE THAT THE COMPRESSOR IS OFF.
1 Insert the 1/4 female nitto coupler connector to the end of the male connector on the air hose.
2. OPERATION
Switching On
WARNING! TO REDUCE THE RISK OF ELECTRIC
SHOCK, WE RECOMMEND THE USE OF A RESIDUAL
CURRENT DEVICE (RATED AT 30MA OR LESS).
WARNING! DO NOT ATTEMPT TO ADJUST/MODIFY
THE SAFETY VALVE IN ANY WAY. THE SAFETY VALVE
INSTALLED ON THIS AIR COMPRESSOR IS DESIGNED
TO AUTOMATICALLY RELEASE PRESSURE IN CASE OF
EXCESS PRESSURE BUILD UP IN THE TANK.
1 Attach the desired tool to the quick release coupling of the air hose.
2 Attach the 1/4”male nitto quick plug into the air tool you wish to use.
2 Connect the compressors power cord to the mains power supply.
3 To switch ON the equipment, set the
On/Off switch to position “I” (On).
3 Pull back the sleeve of the quick-lock coupling whilst pushing in the 1/4”nitto quick plug. The quick-lock sleeve will spring forward automatically, connecting the accessory.
Disconnecting
1 To disconnect the air tool, pull back the sleeve on the quicklock coupling and remove the tool.
WARNING! WHEN RELEASING THE QUICK-
RELEASE COUPLING, BE SURE TO HOLD THE
COUPLING PIECE TO PROTECT YOURSELF
AGAINST INJURY FROM THE REBOUNDING HOSE.
Switching Off
WARNING!
COMPRESSED AIR CAN BE A
DANGEROUS FORM OF ENERGY. GREAT CARE IS
REQUIRED WHEN USING THE COMPRESSOR AND ITS
ACCESSORIES.
1 To switch OFF the equipment, move the On/Off switch to position “0” (Off).
Disconnect the power cord from the mains.
3. INFLATING
Setup
1 Attach the desired tool to the quick release coupling of the air hose.
2 Connect the compressors power cord to the mains power supply.
2 Release remaining pressurised air from tank using the blow gun. Once the pressure has reached 0 PSI, the drain valve should be opened to allow any additional pressure to be released.
3 Close the drain valve.
3 To switch ON the equipment, set the On/Off switch to position “I” (On).
4 Set the compressor to the desired inflation pressure, using the pressure adjustment dial.
4 Disconnect tool and air hose from compressor.
Inflating Tyres
1 Attach the tire chuck to the hose to the compressed air hose.
2 The tyre chuck included in this kit is made for “schrader” valves.
WARNING! AVOID INFLATING THE OBJECTS
ABOVE THE RECOMMENDED INFLATION
PRESSURE. THIS MAY LEAD TO DAMAGE AND/
OR INJURIES.
3 Check compressor is set to the correct pressure.
Pressure can be adjusted using pressure adjustment dial.
4 To inflate the tyre, hold down the tyre chuck onto the schrader valve.
Inflating other items
The compressor kit is supplied with a variety of adapters that can be fitted to the rubber hose or air gun. These adapters are suitable for different valves that are often used on inflatable items:
Adapter A is used for footballs, basketballs, soccer balls etc.
A
Adapters B&C are used for rubber dinghies, inflatable small swimming pools and air beds.
B,C
Adapter D is used for bicycle or car tyres with
“Schrader” valves.
D
5 After a short time, release the air chuck and check the air pressure with the pressure gauge.
Adapter E is used for blowing air to clear work spaces of sawdust or other fine material.
E
Attaching inflation accessories to the Blow Gun
1 To fit the sports ball inflator you’ll need to fit the included nozzle adaptor and screw it into the front of the blow gun.
2 Once the adaptor is installed you can then insert the desired inflation nozzle.
3 Once it is inserted, you can then attach the blow gun to the hose via the nitto fittings.
MACP-015
4. BLOWER PISTOL
Using the Blower Pistol
1 Attach the blow gun nozzle to the blow gun.
2 By varying the pressure on the trigger, you can control the amount of compressed air released through the air nozzle.
WARNING!
OPERATOR IS ADVISED TO WEAR EYE
PROTECTION WHEN USING THE AIR GUN. TAKE
CARE NOT TO BLOW DIRT OR OTHER LOOSE
PARTICLES TOWARDS YOURSELF OR OTHER PERSONS
3 The blower nozzle adapter is useful for blowing dust out of hollow spaces or hard to reach areas, such as vents in electrical items or between the keys of a keyboard.
It is also useful for cleaning soiled equipment.
5. TROUBLESHOOTING
Problem
The compressor does not start
The compressor starts but there is no pressure
The compressor starts, but the tools do not.
Cause
No supply voltage
Insufficient supply voltage
Outside temperature is too low
Motor is overheated
The seals are damaged.
Loose hose connections
Leak in a quick-lock coupling
Solution
Check the supply voltage, the power plug and the socketoutlet.
Make sure that the extension cable is not too long.
Try another product in power point
Never operate with an outside temperature of below 5°c.
Allow the motor to cool down. If necessary, remedy the cause of the overheating.
Check the seals and have any damaged seals replaced by a service centre
Check the compressed air hose and tools and replace if necessary.
Check the quicklock coupling and replace if necessary.
WARNING! DO NOT DIRECT THE JET OF
COMPRESSED AIR TOWARDS PEOPLE OR
ANIMALS.
MAINTENANCE DESCRIPTION OF SYMBOLS
WARNING! BEFORE CLEANING YOUR
COMPRESSOR OR CARRYING OUT ANY
MAINTENANCE PROCEDURE, MAKE SURE
THAT THE MOTOR IS OFF AND THE TOOL
DISCONNECTED FROM THE POWER SUPPLY TO
PREVENT ACCIDENTAL STARTING.
WARNING! WAIT UNTIL THE COMPRESSOR HAS
COMPLETELY COOLED DOWN. RISK OF BURNS!
WARNING! ALWAYS DEPRESSURIZE THE EQUIPMENT
BEFORE CARRYING OUT ANY CLEANING AND
MAINTENANCE WORK.
Cleaning
• Keep the safety devices free of dirt and dust as far as possible.
Wipe the equipment with a clean cloth or blow it with compressed air at low pressure.
• We recommend that you clean the appliance immediately after you use it.
• Clean the appliance regularly with a damp cloth and some soft soap.
Do not use cleaning agents or solvents; these may be aggressive to the plastic parts in the appliance. Ensure that no water can get into the interior of the appliance.
• You must disconnect the hose and any spraying tools from the compressor before cleaning. Do not clean the compressor with water, solvents or the like.
V
~
/min
L
Volts
Alternating Current
Revolutions or reciprocations per minute
Litres
Wear eye, ear & breathing protection
96 Sound power level
Regulatory Compliance Mark
(RCM)
Read Instruction Manual
Hz
W n
0
Hertz
Watts
No load speed
Warning
Beware of electrical voltage
Beware of hot parts.
Warning! The equipment may start up without warning.
CARING FOR THE ENVIRONMENT
Power tools that are no longer usable should not be disposed of with household waste but in an environmentally friendly way. Please recycle where facilities exist. Check with your local council authority for recycling advice.
Recycling packaging reduces the need for landfill and raw materials.
Reuse of recycled material decreases pollution in the environment.
Please recycle packaging where facilities exist. Check with your local council authority for recycling advice.
WARNING! STORE THE COMPRESSOR ONLY IN
A DRY LOCATION WHICH IS NOT ACCESSIBLE
TO UNAUTHORISED PERSONS. ALWAYS STORE
UPRIGHT, NEVER TILTED!
Storage & Transport
Pull the mains plug out of the socket and ventilate the appliance and all connected pneumatic tools. Switch off the compressor and make sure that it is secured in such a way that it cannot be started up again by any unauthorised person. Drain the pressure tank.
Store the compressor only in a dry location which is not accessible to unauthorised persons.
SPARE PARTS
Spare parts can be ordered from the Special Orders Desk at your local Bunnings Warehouse.
For further information, or any parts not listed here, visit www.ozito.com.au or contact Ozito Customer Service:
Australia 1800 069 486
New Zealand 0508 069 486
E-mail: [email protected]
Supply Cords
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
Note: Ozito Industries will not be responsible for any damage or injuries caused by the repair of the tool by an unauthorised person or by mishandling of the tool.
ELECTRICAL SAFETY
WARNING! When using mains-powered tools, basic safety precautions, including the following, should always be followed to reduce risk of fire, electric shock, personal injury and material damage.
Read the whole manual carefully and make sure you know how to switch the tool off in an emergency, before operating the tool.
Save these instructions and other documents supplied with this tool for future reference.
The electric motor has been designed for 230V and 240V only. Always check that the power supply corresponds to the voltage on the rating plate.
Note: The supply of 230V and 240V on Ozito tools are interchangeable for Australia and New Zealand.
If the supply cord is damaged, it must be replaced by an electrician or a power tool repairer in order to avoid a hazard.
Using an Extension Lead
Always use an approved extension lead suitable for the power input of this tool. Before use, inspect the extension lead for signs of damage, wear and ageing. Replace the extension lead if damaged or defective.
When using an extension lead on a reel, always unwind the lead completely. Use of an extension lead not suitable for the power input of the tool or which is damaged or defective may result in a risk of fire and electric shock.
The power outlet for the compressor is recommended to be protected by a 30amp residual current device
GENERAL POWER TOOL SAFETY WARNINGS
WARNING!
Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
1. Work area safety a. Keep work area clean and well lit . Cluttered or dark areas invite accidents. b. Do not operate power tools in explosive atmospheres, such as in the presence of flammable c. Keep children and bystanders away while operating a power tool.
Distractions can cause you a. Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any b. reduce risk of electric shock. c. refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
Do not expose power tools to rain or wet conditions.
Water entering a power tool will increase d. e.
Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power cords increase the risk of electric shock.
When operating a power tool outdoors, use an extension cord suitable for outdoor use.
Use d. e.
Remove any adjusting key or wrench before turning the power tool on.
Do not overreach. Keep proper footing and balance at all times.
A wrench or a key left
This enables better control of f. Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves g. If devices are provided for the connection of dust extraction and collection facilities, ensure h. these are connected and properly used.
Use of dust collection can reduce dust-related hazards.
A careless action can cause severe injury within a fraction of a
4. Power tool use and care a. Do not force the power tool. Use the correct power tool for your application. The correct b. power tool will do the job better and safer at the rate for which it was designed.
Do not use the power tool if the switch does not turn it on and off.
Any power tool that cannot c. Disconnect the plug from the power source and/or the battery pack from the power tool d. preventive safety measures reduce the risk of starting the power tool accidentally. a. Stay alert, watch what you are doing and use common sense when operating a power tool. medication.
A moment of inattention while operating power tools may result in serious personal b. Protective equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries. c. Prevent unintentional starting. Ensure the switch is in the off-position before connecting to your finger on the switch or energising power tools that have the switch on invites accidents. e. Maintain power tools. Check for misalignment or binding of moving parts, breakage of parts power tool repaired before use.
Many accidents are caused by poorly maintained power tools. f. Keep cutting tools sharp and clean.
Properly maintained cutting tools with sharp cutting edges g. are less likely to bind and are easier to control. taking into account the working conditions and the work to be performed. Use of the power tool for operations different from those intended could result in a hazardous situation.
h. Keep handles and grasping surfaces dry, clean and free from oil and grease.
Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations.
a. Have your power tool serviced by a qualified repair person using only identical replacement
AIR COMPRESSOR SAFETY WARNINGS
supervision to ensure that they do not play with play with the appliance.
The appliance is not to be used by persons (including children) with reduced physical, sensory supervision or instruction.
Children being supervised are not to play with the appliance.
WARNING. Before connecting a tool to a power source (mains switch power point receptacle, outlet, etc.) be sure that the voltage supply is the same as that specified on the nameplate of the tool. A power source with a voltage greater than that specified for the tool can result in serious injury to the user, as well as damage to the tool. If in doubt, do not plug in the tool. Using a power source with a voltage less than the nameplate rating is harmful to the motor.
Always remove the plug from the mains socket before making any adjustments or maintenance.
• To reduce the risk of fire or explosion, never spray flammable liquids in a confined area. If sparks come into contact with petrol vapours or solvents, they may ignite the vapours and cause a fire or explosion.
• Always operate the compressor in a well ventilated area. Do not smoke while spraying. Do not spray where sparks or flames are present. Keep the compressor as far away from the spray area as possible.
• The solvents trichloroethane and methylene chloride can chemically react with the aluminium used in some paint spray guns and form an explosion. If these solvents are used, ensure that only stainless steel spray equipment is connected. The compressor is not affected by the use of these solvents.
• Never directly inhale the compressed air produced by a compressor and do not use it for charging breathing tanks.
• Do not use welding equipment in close proximity to the compressor. Do not weld anything to the air tank of the compressor: this could dangerously weaken the tank and will void the warranty.
• Do not use the compressor outdoors when it is raining or on a wet surface; either situation could cause an electric shock.
• Always maintain a safety distance of at least 3 meters between the compressor and the work area,
Ensure that the compressor is on a stable surface.
• Always use the handle to move the compressor.
• Never let the compressor come into contact with water or other liquids, as the appliance is live, this could cause electrocution or short-circuits. Never use the appliance with bare feet, wet hands or wet feet.
• Never pull on the power cable to disconnect the plug from the power outlet or to move the compressor.
• The compressed air produced by the compressor cannot not be used for pharmaceutical, food or medical purposes or to fill the air bottles of scuba divers.
• Do not cover the air inlets on the compressor.
• Compressors and lines reach high temperatures during operation. Avoid contact! Risk of burns!
• Gases or vapours drawn in by the compressor have to be kept free of constituents that may cause fire or explosions inside the compressor.
• When you disconnect the hose coupling, hold the coupling element in your hand to prevent injury from the whiplashing hose.
• Never point the blow-out gun at other persons and never use it to clean clothes that are still being worn.
• Be certain to read all the labels on the containers of paint or other materials to be sprayed. Closely follow all safety instructions. Use a respirator mask if there is a chance that you might otherwise inhale the spray material. Carefully check the effectiveness of any respirator mask you intend using.
• Always wear safety goggles or glasses when using the air compressor. Never point the nozzle of an accessory towards any part of your body or towards another person.
• Keep the compressor at least 300mm from the nearest wall to ensure adequate ventilation for cooling purposes.
• Protect the air hose and cordset from damage. Inspect for weak or worn spots regularly and replace if necessary.
• Avoid using an extension cord with this product. Use additional air hose instead of an extension cord to prevent power loss and possible damage to the motor. Use of an extension cord voids the warranty.
• Always switch off the compressor before switching off the power or removing the power plug.
• After using the compressor, switch off the on/off button, disconnect the power supply and release any remaining pressure.
• Do not attempt to remove any part of the machine whilst it is under pressure.
• Use safety equipment including safety goggles or shield, ear protection, breathing or respirator mask and protective clothing.
Wear goggles, wear earmuffs, wear a breathing mask
Never apply the outlet air of this compressor directly on to any part of a person’s body. Do not attempt to block the air outlet with your finger or any part of your body.
The tool must be used only for its prescribed purpose. Any use other than those mentioned in this
Manual will be considered a case of misuse. The user and not the manufacturer shall be liable for any damage or injury resulting from such cases of misuse.
The manufacturer shall not be liable for any changes made to the tool nor for any damage resulting from such changes.
Even when the tool is used as prescribed it is not possible to eliminate all residual risk factors. The following hazards may arise in connection with the tool’s construction and design:
• Damage to the lungs if an effective breathing mask is not worn.
• Damage to hearing if effective earmuffs are not worn.
• Damage to the eyes if effective safety goggles or shield are not worn.
WARNING.
I n the event that an air line is cut or broken, the air supply must be turned off at the compressor. A broken air line which is not supported is extremely dangerous and can whip around very quickly, both with the capability of striking people, and blowing foreign particles into the air.
Do not attempt to catch the air line but immediately keep bystanders well clear and turn off the air supply to the hose, turn off the compressor at the On / Off button, and then remove the hose from the compressor.
Shkarko
Reklamë