YASKAWA MOTOMAN DX100 Instructions Manual
Werbung
Werbung
DX100 OPTIONS
INSTRUCTIONS
FOR HIGH-SPEED ETHERNET SERVER FUNCTION
Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.
MOTOMAN INSTRUCTIONS
MOTOMAN INSTRUCTIONS
DX100 INSTRUCTIONS
DX100 OPERATOR’S MANUAL
DX100 MAINTENANCE MANUAL
The DX100 Operator’s manual above corresponds to specific usage.
Be sure to use the appropriate manual.
Part Number: 162529-1CD
Revision: 5
MANUAL NO.
HW1480958
6
1 of 119
DX100
162529-1CD
Copyright © 2018, 2017, 2014, 2012 Yaskawa America, Inc.
Terms of Use and Copyright Notice
All rights reserved. This manual is freely available as a service to Yaskawa customers to assist in the operation of Motoman robots, related equipment and software This manual is copyrighted property of Yaskawa and may not be sold or redistributed in any way. You are welcome to copy this document to your computer or mobile device for easy access but you may not copy the PDF files to another website, blog, cloud storage site or any other means of storing or distributing online content.
Printed in the United States of America
First Printing, 2012
Yaskawa America, Inc.
Motoman Robotics Division
100 Automation Way
Miamisburg, OH 45342
Phone: 937-847-6200 www.motoman.com ii
HW1480958
2 of 119
162529-1CD
DX100
MANDATORY
• This manual explains the high-speed Ethernet server function of the
DX100 system and general operations. Read this manual carefully and be sure to understand its contents before handling the DX100.
• General items related to safety are listed in Chapter 1: Safety of the
DX100 Instructions. To ensure correct and safe operation, carefully read the DX100 Instructions before reading this manual.
CAUTION
• Some drawings in this manual are shown with the protective covers or shields removed for clarity. Be sure all covers and shields are replaced before operating this product.
• The drawings and photos in this manual are representative examples and differences may exist between them and the delivered product.
• YASKAWA may modify this model without notice when necessary due to product improvements, modifications, or changes in specifications.
• If such modification is made, the manual number will also be revised.
• If your copy of the manual is damaged or lost, contact a YASKAWA representative to order a new copy. The representatives are listed on the back cover. Be sure to tell the representative the manual number listed on the front cover.
• YASKAWA is not responsible for incidents arising from unauthorized modification of its products. Unauthorized modification voids your product's warranty.
iii
HW1480958
3 of 119
DX100
162529-1CD
We suggest that you obtain and review a copy of the ANSI/RIA National
Safety Standard for Industrial Robots and Robot Systems (ANSI/RIA
R15.06-2012). You can obtain this document from the Robotic Industries
Association (RIA) at the following address:
Robotic Industries Association
900 Victors Way
P.O. Box 3724
Ann Arbor, Michigan 48106
TEL: (734) 994-6088
FAX: (734) 994-3338 www.roboticsonline.com
Ultimately, well-trained personnel are the best safeguard against accidents and damage that can result from improper operation of the equipment. The customer is responsible for providing adequately trained personnel to operate, program, and maintain the equipment. NEVER
ALLOW UNTRAINED PERSONNEL TO OPERATE, PROGRAM, OR
REPAIR THE EQUIPMENT!
We recommend approved Yaskawa training courses for all personnel involved with the operation, programming, or repair of the equipment.
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
iv
HW1480958
4 of 119
162529-1CD
DX100 Notes for Safe Operation
Notes for Safe Operation
Read this manual carefully before installation, operation, maintenance, or inspection of the DX100.
In this manual, the Notes for Safe Operation are classified as “DANGER”,
“WARNING”, “CAUTION”, “MANDATORY” or ”PROHIBITED”.
DANGER
WARNING
CAUTION
Indicates an imminent hazardous situation which, if not avoided, could result in death or serious injury to personnel.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury to personnel.
Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury to personnel and damage to equipment.
It may also be used to alert against unsafe practices.
MANDATORY
Always be sure to follow explicitly the items listed under this heading.
PROHIBITED
Must never be performed.
Even items described as “CAUTION” may result in a serious accident in some situations.
At any rate, be sure to follow these important items
NOTE
To ensure safe and efficient operation at all times, be sure to follow all instructions, even if not designated as “DANGER”,
“WARNING” and “CAUTION”.
v
HW1480958
5 of 119
DX100
162529-1CD
Notes for Safe Operation
WARNING
• Before operating the manipulator, check that servo power is turned
OFF pressing the emergency stop buttons on the programming pendant.
When the servo power is turned OFF, the SERVO ON LED on the programming pendant is turned OFF.
Injury or damage to machinery may result if the emergency stop circuit cannot stop the manipulator during an emergency. The manipulator should not be used if the emergency stop buttons do not function.
Figure 1: Emergency Stop Button
• Once the emergency stop button is released, clear the cell of all items which could interfere with the operation of the manipulator.
Then turn the servo power ON.
Injury may result from unintentional or unexpected manipulator motion.
Figure 2: Release of Emergency Stop
TURN
• Observe the following precautions when performing teaching operations within the P-point maximum envelope of the manipulator:
– Be sure to use a lockout device to the safeguarding when going inside. Also, display the sign that the operation is being performed inside the safeguarding and make sure no one closes the safeguarding.
View the manipulator from the front whenever possible.
– Always follow the predetermined operating procedure.
– Keep in mind the emergency response measures against the manipulator’s unexpected motion toward you.
– Ensure that you have a safe place to retreat in case of emergency.
Improper or unintended manipulator operation may result in injury.
• Confirm that no person is present in the P-point maximum envelope of the manipulator and that you are in a safe location before:
– Turning ON the power for the DX100.
– Moving the manipulator with the programming pendant.
– Running the system in the check mode.
– Performing automatic operations.
Injury may result if anyone enters the P-point maximum envelope of the manipulator during operation. Always press an emergency stop button immediately if there is a problem.
The emergency stop buttons is on the programming pendant.
vi
HW1480958
6 of 119
162529-1CD
DX100 Definition of Terms Used In this Manual
CAUTION
• Perform the following inspection procedures prior to conducting manipulator teaching. If problems are found, repair them immediately, and be sure that all other necessary processing has been performed.
– Check for problems in manipulator movement.
– Check for damage to insulation and sheathing of external wires.
• Always return the programming pendant to the hook on the cabinet of the DX100 after use.
The programming pendant can be damaged if it is left in the manipulator's work area, on the floor, or near fixtures.
• Read and understand the Explanation of Warning Labels in the
DX100 Instructions before operating the manipulator:
Definition of Terms Used In this Manual
The MOTOMAN is the YASKAWA industrial robot product.
The MOTOMAN usually consists of the manipulator, the controller, the programming pendant, and the manipulator cables.
In this manual, the equipment is designated as follows:
Equipment
DX100 controller
DX100 programming pendant
Cable between the manipulator and the controller
Manual Designation
DX100
Programming pendant
Manipulator cable vii
HW1480958
7 of 119
DX100
162529-1CD
Description of the Operation Procedure
Descriptions of the programming pendant, buttons, and displays are shown as follows:
Equipment
Programming
Pendant
Character
Keys
Symbol
Keys
Manual Designation
The keys which have characters printed on them are denoted with [ ].
ex. [ENTER]
The keys which have a symbol printed on them are not denoted with [ ] but depicted with a small picture.
ex. page key
The cursor key is an exception, and a picture is not shown.
Axis Keys
Number Keys
“Axis Keys” and “Number Keys” are generic names for the keys for axis operation and number input.
Keys pressed simultaneously
Displays
When two keys are to be pressed simultaneously, the keys are shown with a “+” sign between them, ex. [SHIFT]+[COORD]
The menu displayed in the programming pendant is denoted with { }.
ex. {JOB}
Description of the Operation Procedure
In the explanation of the operation procedure, the expression [Select • • •]” means that the cursor is moved to the object item and the SELECT key is pressed, or that the item is directly selected by touching the screen.
Registered Trademark
In this manual, names of companies, corporations, or products are trademarks, registered trademarks, or bland names for each company or corporation. The indications of (R) and TM are omitted.
viii
HW1480958
8 of 119
162529-1CD
DX100 Safeguarding Tips
Safeguarding Tips
All operators, programmers, maintenance personnel, supervisors, and anyone working near the system must become familiar with the operation of this equipment. All personnel involved with the operation of the equipment must understand potential dangers of operation. General safeguarding tips are as follows:
• Improper operation can result in personal injury and/or damage to the equipment. Only trained personnel familiar with the operation of this equipment, the operator's manuals, the system equipment, and options and accessories should be permitted to operate this equipment.
• Improper connections can damage the equipment. All connections must be made within the standard voltage and current ratings of the equipment.
• The system must be placed in Emergency Stop (E-Stop) mode whenever it is not in use.
• In accordance with ANSI/RIA R15.06-2012, section 4.2.5, Sources of
Energy, use lockout/tagout procedures during equipment maintenance. Refer also to Section 1910.147 (29CFR, Part 1910),
Occupational Safety and Health Standards for General Industry
(OSHA).
Mechanical Safety Devices
The safe operation of this equipment is ultimately the users responsibility.
The conditions under which the equipment will be operated safely should be reviewed by the user. The user must be aware of the various national codes, ANSI/RIA R15.06-2012 safety standards, and other local codes that may pertain to the installation and use of this equipment.
Additional safety measures for personnel and equipment may be required depending on system installation, operation, and/or location. The following safety equipment is provided as standard:
• Safety barriers
• Door interlocks
• Emergency stop palm buttons located on operator station
Check all safety equipment frequently for proper operation. Repair or replace any non-functioning safety equipment immediately.
ix
HW1480958
9 of 119
162529-1CD
DX100 Programming, Operation, and Maintenance Safety
Programming, Operation, and Maintenance Safety
All operators, programmers, maintenance personnel, supervisors, and anyone working near the system must become familiar with the operation of this equipment. Improper operation can result in personal injury and/or damage to the equipment. Only trained personnel familiar with the operation, manuals, electrical design, and equipment interconnections of this equipment should be permitted to program, or maintain the system.
All personnel involved with the operation of the equipment must understand potential dangers of operation.
• Inspect the equipment to be sure no potentially hazardous conditions exist. Be sure the area is clean and free of water, oil, debris, etc.
• Be sure that all safeguards are in place. Check all safety equipment for proper operation. Repair or replace any non-functioning safety equipment immediately.
• Check the E-Stop button on the operator station for proper operation before programming. The equipment must be placed in Emergency
Stop (E-Stop) mode whenever it is not in use.
• Back up all programs and jobs onto suitable media before program changes are made. To avoid loss of information, programs, or jobs, a backup must always be made before any service procedures are done and before any changes are made to options, accessories, or equipment.
• Any modifications to the controller unit can cause severe personal injury or death, as well as damage to the robot! Do not make any modifications to the controller unit. Making any changes without the written permission from Yaskawa will void the warranty.
• Some operations require standard passwords and some require special passwords.
• The equipment allows modifications of the software for maximum performance. Care must be taken when making these modifications.
All modifications made to the software will change the way the equipment operates and can cause severe personal injury or death, as well as damage parts of the system. Double check all modifications under every mode of operation to ensure that the changes have not created hazards or dangerous situations.
• This equipment has multiple sources of electrical supply. Electrical interconnections are made between the controller and other equipment. Disconnect and lockout/tagout all electrical circuits before making any modifications or connections.
• Do not perform any maintenance procedures before reading and understanding the proper procedures in the appropriate manual.
• Use proper replacement parts.
• Improper connections can damage the equipment. All connections must be made within the standard voltage and current ratings of the equipment.
x
HW1480958
10 of 119
162529-1CD
DX100 Maintenance Safety
Maintenance Safety
Turn the power OFF and disconnect and lockout/tagout all electrical circuits before making any modifications or connections.
Perform only the maintenance described in this manual. Maintenance other than specified in this manual should be performed only by Yaskawatrained, qualified personnel.
Summary of Warning Information
This manual is provided to help users establish safe conditions for operating the equipment. Specific considerations and precautions are also described in the manual, but appear in the form of Dangers, Warnings,
Cautions, and Notes.
It is important that users operate the equipment in accordance with this instruction manual and any additional information which may be provided by Yaskawa. Address any questions regarding the safe and proper operation of the equipment to Yaskawa Customer Support.
xi
HW1480958
11 of 119
162529-1CD
DX100 Customer Support Information
Customer Support Information
If you need assistance with any aspect of your DX100 system, please contact YASKAWA Customer Support at the following 24-hour telephone number:
(937) 847-3200
For routine technical inquiries, you can also contact YASKAWA Customer
Support at the following e-mail address: [email protected]
When using e-mail to contact YASKAWA Customer Support, please provide a detailed description of your issue, along with complete contact information. Please allow approximately 24 to 36 hours for a response to your inquiry.
NOTE
Please use e-mail for routine inquiries only. If you have an urgent or emergency need for service, replacement parts, or information, you must contact YASKAWA Customer
Support at the telephone number shown above.
Please have the following information ready before you call Customer
Support:
• System
• Robots
DX100
___________________________
• Primary Application
• Controller
• Software Version
___________________________
DX100
Access this information on the
Programming Pendant’s LCD display screen by selecting {MAIN
MENU} - {SYSTEM INFO} -
{VERSION}
• Robot Serial Number
• Robot Sales Order Number
Located on the robot data plate
Located on the DX100 controller data plate xii
HW1480958
12 of 119
162529-1CD
DX100 Table of Contents
Table of Contents
3.3.12 Integer Type Variable (I) Reading / Writing Command..................................... 3-39
3.3.13 Double Precision Integer Type Variable (B) Reading / Writing Command ....... 3-40
xiii
HW1480958
13 of 119
162529-1CD
DX100 Table of Contents
3.3.14 Real Type Variable (R) Reading / Writing Command ....................................... 3-41
3.3.15 Character Type Variable (S) Reading Writing Command................................. 3-42
3.3.16 Robot Position Type Variable (P) Reading / Writing Command ....................... 3-43
3.3.17 Base Position Type Variable (Bp) Reading / Writing Command....................... 3-46
3.3.18 External Axis Type Variable (Ex) Reading / Writing Command........................ 3-48
3.3.22 Character String Display Command To The Programming Pendant................ 3-53
3.3.29 Plural Byte Type Variable (B) Reading / Writing Command ............................. 3-62
3.3.30 Plural Integer Type Variable (I) Reading / Writing Command........................... 3-64
3.3.31 Plural Double Precision Integer Type Variable (B)
3.3.32 Plural Real Type Variable (R) Reading / Writing Command............................. 3-66
3.3.33 Plural Character Type Variable (S) Reading / Writing Command..................... 3-67
3.3.34 Plural Robot Position Type Variable (P) Reading / Writing Command ............. 3-69
3.3.35 Plural Base Position Type Variable (Bp) Reading / Writing Command ............ 3-71
3.3.36 Plural External Axis Type Variable (Ex) Reading / Writing Command.............. 3-73
3.3.37 Alarm Data Reading Command
(for Applying the Sub Code Character Strings) ................................................ 3-75
3.3.38 Alarm History Reading Command
(for Applying the Sub Code Character Strings) ................................................ 3-78
3.3.39 Move instruction command (Type Cartesian coordinates) ............................... 3-81
xiv
HW1480958
14 of 119
162529-1CD
DX100 Table of Contents
xv
HW1480958
15 of 119
162529-1CD
DX100 1 Introductions
1.1 Preparation
1 Introductions
The high-speed Ethernet server function is a new communication protocol to enable high-speed Ethernet communication between the DX100 and external devices such as PC, etc.
Followings are the characteristics of this function.
(1) It becomes possible to communicate in more than two times higher peed than the present Ethernet server function and more then 5 times higher speed than the present Ethernet data transmission function.
(2) It combines the present Ethernet data transmission function (host control) and the present Ethernet server function. (except for some functions)
(3) It corresponds to the file receiving/transmission function to which the present Ethernet server function dose not correspond.
(4) It is incompatible to the present data transmission function (host control) and the present Ethernet server function. Therefore,
MotoCom communication library (Ver3.6), which corresponds to the high-speed Ethernet server function, will be released at the same time.
(5) It is also possible to create a communication program without using MotoCom since this function is publishing its communication protocol.
(6) To maintain the compatibility with existing communication software, the present data transmission function and the present
Ethernet server function are still available.
1.1
Preparation
This high-speed Ethernet server function is an expansion option to the
DX100 Ethernet function. In this reason, when using this function, the PC should be ready to use the DX100 Ethernet function.
1.2
Restriction
• This function cannot use concurrently with MotoPlus function, PP customizing function, other Ethernet functions and the data transmission function (serial).
• To increase the speed, the protocol of this function was modified.
Therefore, it has no compatibility with the data transmission function and the Ethernet server function.
To retain the compatibility, MotoCom communication library (Ver3.6) will be released at the same time with this function. Please use
MotoCom communication library of later version than Ver3.6.
1-1
HW1480958
16 of 119
162529-1CD
DX100
2 System Setting
2 System Setting
2.1 Before using the System
To use the high-speed Ethernet server function, configuration of the following settings are required.
2.1
Before using the System
The high-speed Ethernet server function is designed as an expansion option to the DX100 Ethernet function. Before using this function, it is required to make the DX100 Ethernet host control function available.
For more details, see chapter 3 “Ethernet Function Settings” in the
“DX100 OPTIONS INSTRUCTIONS FOR ETHERNET FUNCTION”.
2.2
Parameter Setting
Set the following parameters before using this function.
Parameter
RS022
RS029
RS034
RS035
Parameter
S2C541
S2C542
S2C680
Details
Instance 0 permitted
(Instance 0 is used as the ordinal data)
A job during the playback operation, Loading of a variable
Timer to wait for a replay
Timer for monitoring end of text
Setting value
1
1
200
200
2.3
Setting of Relevant Parameter
Details
Specify the permission of variable and I/O input during the play mode
(0: writing is allowed / 1: writing is not allowed)
Specify the permission of variable and I/O input during the edit-lock status
(0: writing is allowed / 1: writing is not allowed)
Specify the permission of the batch data backup function
(0: INVALID 1: Create RAMDISK at the STARTUP)
When shipping
1
1
1
NOTE
When setting 0 toS2C541 (writing is allowed), writing is possible even during the playback operation. However, please be noted that this setting may affect the manipulator’s cycle time due to some writing timings or their frequencies.
NOTE
Following are the status to which specifying of the “edit-lock status” is permitted by S2C542 parameter.
• During an alarm
• When an external memory device is operated
• When the data transmission function is used
• Specific input EDIT_LOCK (#40064) is turned ON
2-1
HW1480958
17 of 119
DX100
162529-1CD
2 System Setting
2.4 Setting of Command Remote
2.4
Setting of Command Remote
Set Management mode as Security mode, and select {IN/OUT} –
{PSEUDO INPUT SIGNAL} to appear the following display. Move the cursor to the #82015 CMD REMOTE SEL, and press [INTER LOCK] +
[SELECT] to select [ON].
2.5
Setting of a Batch Data Backup Function
With the batch data backup function, the data saved in the DX100 such as system setting or operational condition are collectively backed up by using the command from High Speed Ethernet Server Function. Set the following procedures in advance to use this function.
Set Management mode as Security mode. Select {CONTROLLER SET} +
{AUTO BACKUP SET} in the Main Menu, and following display will appear. Set the DEVICE as “RAMDISK”.
2-2
HW1480958
18 of 119
162529-1CD
DX100 2 System Setting
2.5 Setting of a Batch Data Backup Function
NOTE
• A batch data backup function is available for software version DS3.00 or higher.
• Refer to DX100 Instruction section 9.3 “Auto Backup
Function” for more details.
• Refer to DX100 Instruction section 9.4 “Loading the
Backup Data from the CompactFlash” for using files from the restore system which is backed up by command from
High Speed Ethernet Server Function.
• During an alarm is occurring, it would not be able to change the device. Thus, operate after resetting the alarm.
• When the parameter is S2C680=0, “RAMDISK” will not appear in the “AUTO BACKUP SET” display. Make sure to set the parameter S2C680.
2-3
HW1480958
19 of 119
162529-1CD
DX100 3 Transmission Procedure
3.1 Packet Format
3 Transmission Procedure
3.1
Packet Format
Transmission packet of the high-speed Ethernet server function is composed of header part (32 byte) + data part (changeable: 479 byte at max.)
The transmission packet consists of “request”, which transmits the data from the PC to the DX100, and “answer”, which transmits the data from the DX100 to the PC.
The sub-header setting composition of “request” and “answer” are different. And the setting value of the “answer” varies in accordance with the replying contents.
Followings are the format of each packet.
Request (the PC to the DX100)
4 Byte
Type Byte 0 Byte 1 Byte 2 Byte 3
Identifier
Data size
Reserve 1 / processing division
Block No.
Reserve 2
Sub-header
Data division
Fixed character strings for identification (YERC)
Header part size
(fixed to 0x20)
Reserve 1
(fixed to “3”)
Processing division
Data part size
(variable value)
ACK
Reserve2 (fixed to “99999999”)
Command No.
Attribute Service (when requested)
Instance
Padding
Data division (variable:479Byte at maximum)
Request ID
Header part
(fixed to 32Byte)
3-1
HW1480958
20 of 119
162529-1CD
DX100 3 Transmission Procedure
3.1 Packet Format
Answer (the DX100 to the PC)
4 Byte
Type Byte 0 Byte 1 Byte 2 Byte 3
Identifier
Data size
Reserve 1 / processing division
Block No.
Reserve 2
Sub-header
Data division
Fixed character strings for identification (YERC)
Header part size
(fixed to 0x20)
Data part size
(variable value)
Reserve 1
(fixed to “3”)
Processing division
ACK
Allocate the block number from 0 to0x7fff_ffff
Add 0x8000_0000 to the last block
Reserve 2 (fixed to “99999999”)
Service
(when replying)
Status:
When normal operation:0x00
When abnormal operation: other than 0x00
Added status size
Added status size
1) Padding
Data division (variable:479Byte at maximum)
Request ID
Padding
1 For the details of added status, please refer to chapter 5 “Added Status Code”
.
Header part
(fixed to 32Byte)
3-2
HW1480958
21 of 119
162529-1CD
DX100 3 Transmission Procedure
3.1 Packet Format
Item
Identifier
Header part size
Data part size
Reserve 1
Processing division
ACK
Request ID
Block No.
Reserve 2
Sub-header
(request)
8byte
Command No.
2byte
Instance
Attribute
2byte
1byte
Sub-header
(answer)
Padding
Service
(request)
1byte
Service (answer) 1byte
Status 1byte
Added status size
Added status
1byte
2byte
Variable
Data size
4byte
2byte
2byte
1byte
1byte
1byte
1byte
4byte
Settings
Fixed to “YERC”
Size of header part (fixed to 0x20)
Size of data part (variable)
Fixed to “3”
1: robot control
2: file control
Request: 0
Other than request: 1
Identifying ID for command session
(increment this ID every time the client side outputs a new command. In reply to this, server side answers the received value.)
Request: 0
Answer: add 0x8000_0000 to the last packet.
Data transmission other than above: add 1
(max: 0x7FFF_FFFF)
Fixed to “99999999”
Execute processing by this command.
(conforms to “Class” of CIP communication protocol)
Define SECTION to execute a command.
(conforms to “Padding” of CIP communication protocol)
Define SUB SECTION for executing a command.
Attribute: (conforms to “Attribute” of CIP communication protocol)
Define data accessing method.
Add 0s80 to service (request).
0x00: normal reply
Other than 0x00: abnormal reply
Size of added status
(0: not specified / 1: 1 WORD data / 2: 2 WORD data)
Error code specified by added status size
For details, refer to
.
Reserve area
3-3
HW1480958
22 of 119
162529-1CD
DX100 3 Transmission Procedure
3.1 Packet Format
Details of sub-header
• Sub header (request)
Sub header (request) Command No.
Attribute Service (request)
Instance
Padding
• Sub header (answer/ no added status)
Sub header (request) Service (answer) Status: normal:
0x00
Added status:0x14809580
Added status: size:
0x00
Padding
Padding
• Sub header (answer/ with added status)
Sub header (request) Service (answer) Status: abnormal: other than 0x00
Added status:0x00001010
Added status: size:0x01
Padding
Padding
3-4
HW1480958
23 of 119
DX100
162529-1CD
3 Transmission Procedure
3.2 Outline
3.2
Outline
The transmission/receiving flow of the transmission packet is divided into
robot control and file control. Please refer to section 3.3 “Respective
for the details of respective robot control commands (request/answer) and
section 3.4 “File Control Command”
for the details of respective file control commands.
[Ex. When Reading]
3.2.1 Robot Control/Status Reading
PC
UDP: optional
Socket opened
Request (status reading request)
Answer (status)
Socket closed
More than two commands are occasionally processed till the socket is closed
UDP:10040
DX100
Request
0x03
0x00
0x0020
0x0072
<Format>
“YERC”
0x01
0x0000_0000
“99999999”
0x0000
0x00
Identifier
Header part size
0x00 Reserve 1 Processing division
Block No.
Data part size
ACK Request ID
0x01
0x0001
0x0000
Reserve 2
Command No.
Attribute Service
Instance
Padding
Answer
0x03
0x0020
0x01
“YERC”
0x01
0x0000
0x00
0x81
0x8000_0000
“99999999”
0x00 0x00 0x00
0x0000 0x0000
Status data 1
Status data 2
<Format>
Identifier
Header part size
Reserve 1 Processing division
Data part size
ACK Request ID
Block No.
Reserve 2
Service
Added status status size
Padding
Reading value 1
Reading value 2
3-5
HW1480958
24 of 119
162529-1CD
DX100 3 Transmission Procedure
3.2 Outline
[Ex. When Writing]
3.2.2 Robot Control/Data Writing to Register
PC
UDP: optional UDP:10040
Socket opened
Request (request of data writing to register)
DX100
Answer (writing result)
Socket closed
Request
0x03
0x0020
0x01
“YERC”
0x00
0x0002
0x01
0x0000_0000
‘99999999’
0x0079
0x00 0x02
Register data
Register No.
0x0000
<Format>
Identifier
Header part size
Reserve 1 Processing division
Block No.
Data part size
ACK Request ID
Reserve 2
Command No.
Attribute Service
Writing value
Instance
Padding
Answer
0x03
0x0020
0x01
‘YERC’
0x01
0x0000
0x01
0x82
0x8000_0000
‘99999999’
0x00 0x00 0x00
0x0000 0x0000
<Format>
Identifier
Header part size
Reserve 1 Processing division
Block No.
Data part size
ACK Request ID
Service
Reserve 2
Status Added status size
Added status
Padding
Padding
3-6
HW1480958
25 of 119
DX100
162529-1CD
3 Transmission Procedure
3.2 Outline
3.2.3 File Control
PC
UDP: optional
Socket opened
Request 1 (request saving)
Data 1 (file data 1)
ACK 1 (reply of receiving)
Data 2 (file data 2)
ACK 2 (reply of receiving)
UDP:10040
DX100
The last data (file data N: the last file data)
ACK N (reply of receiving)
Socket closed
Request 1
0x03
0x0020
0x02
“YERC”
0x00
0x000B
0x02
0x0000_0000
“99999999”
0x00
T
J
J
0x00
0x16
E
O
B
S
B
I
0x0000
0x00
T
.
<Format>
Identifier
Header part size
Reserve 1 Processing division
Block No.
Reserve 2
Command No.
Attribute Service
File name
Data part size
ACK Request
ID
Instance
Padding
3-7
HW1480958
26 of 119
162529-1CD
DX100 3 Transmission Procedure
3.2 Outline
Data 1
0x03
0x0020
0x02
“YERC”
0x01
0x01d f
0x02
0x96
0x0000_0001
“99999999”
0x00 0x00 0x00
0x0000 0x0000
File data 1
<Format>
Identifier
Header part size
Reserve 1 Processing division
Data part size
ACK Request ID
Block No.
Reserve 2
Service Status
Added status
Added status size
Padding
Padding
File data 1
ACK1
0x03
0x0020
0x02
“YERC”
0x01
0x0000
0x02
0x00
0x0000_0001
“99999999”
0x00
0x16
0x0000
0x00
<Format>
Identifier
Header part size
Reserve 1 Processing division
Block No.
Data part size
ACK Request ID
Reserve 2
Command No.
Attribute Service
Instance
Padding
Data 2
“YERC”
0x03
0x0020
0x96
0x02 0x01
0x0000_0002
“99999999”
0x00 0x00
0x01d?
0x02
0x00
0x0000 0x0000
File data 2
<Format>
Header part size
Reserve 1
Identifier
Processing division
Data part size
ACK
Block No.
Request ID
Service
Reserve 2
Status Added status size
Added status
Padding
Padding
File data 2
3-8
HW1480958
27 of 119
162529-1CD
DX100 3 Transmission Procedure
3.2 Outline
ACK2
“YERC”
0x0020 0x0000
0x03 0x02 0x01
0x0000_0002
“99999999”
0x00
0x00
0x16
0x0000
0x00
0x02
<Format>
Header part size
Reserve 1
Identifier
Processing division
Data part size
ACK
Block No.
Reserve 2
Command No.
Attribute Service
Request ID
Instance
Padding
The last data (N)
0x0020
0x03
0x96
“YERC”
0x02 0x01
0x8000_000N
“99999999”
0x00 0x00
0x0008
0x02
0x00
0x0000 0x0000
File data N
<Format>
Header part size
Reserve 1
Identifier
Processing division
Data part size
ACK
Block No.
Request ID
Service
Reserve 2 status Added status size
Added status
Padding
Padding
File data N
The last ACK (N)
“YERC”
0x0020 0x0000
0x03 0x02 0x01
0x8000_000N
“99999999”
0x00
0x00
0x16
0x0000
0x00
0x02
<Format>
Header part size
Reserve 1
Identifier
Processing division
Data part size
ACK
Block No.
Reserve 2
Command No.
Attribute Service
Request ID
Instance
Padding
3-9
HW1480958
28 of 119
162529-1CD
DX100 3 Transmission Procedure
3.2 Outline
3.2.4 File Control (File Loading)
PC
UDP: optional
Socket opened
Request 1 (request loading)
ACK (to command)
Data 1 (file data 1)
ACK 1 (reply 1)
UDP:10040
DX100
The last data (data N)
The last ACK (reply N)
Socket closed
Request 1
0x03
0x0020
0x02
“YERC”
0x00
0x000B
0x03
0x0000_0000
“99999999”
0x0000
T
J
J
0x00
0x15
E
O
B
S
B
I
0x0000
0x00
T
.
<Format>
Identifier
Header part size
Reserve 1 Processing division
Data part size
ACK Request ID
Command No.
Attribute Service
Block No.
Reserve 2
File name
Instance
Padding
ACK (to request)
0x03
0x0020
0x02
“YERC”
0x01
0x0000
0x03
0x95
0x0000_0000
“99999999”
0x00 0x00 0x00
0x0000 0x0000
<Format>
Identifier
Header part size
Reserve 1 Processing division
Data part size
ACK Request ID
Service
Block No.
Reserve 2
Status
Added status
Added status size
Padding
Padding
3-10
HW1480958
29 of 119
162529-1CD
DX100 3 Transmission Procedure
3.2 Outline
Data 1
0x03
0x0020
0x02
“YERC”
0x01
0x01d?
0x03
0x0000_0001
“99999999”
0x0000
0x00
0x15
File data 1
0x0000
0x00
<Format>
Identifier
Header part size
Reserve 1 Processing division
Block No.
Data part size
ACK Request ID
Reserve 2
Command No.
Attribute Service
File data 1
Instance
Padding
ACK1
0x03
0x0020
0x02
“YERC”
0x01
0x0000
0x03
0x95
0x0000_0001
“99999999”
0x00 0x00 0x00
0x0000 0x0000
<Format>
Identifier
Header part size
Reserve 1 Processing division
Block No.
Data part size
ACK Request ID
Service
Reserve 2
Status Added status size
Added status
Padding
Padding
The last data (N)
0x03
0x0020
0x02
“YERC”
0x01
0x0008
0x03
0x8000_000N
“99999999”
0x0000
0x00
0x15
File data N
0x0000
0x00
<Format>
Identifier
Header part size
Reserve 1 Processing division
Block No.
Data part size
ACK Request ID
Reserve 2
Command No.
Attribute Service
File data N
Instance
Padding
3-11
HW1480958
30 of 119
162529-1CD
DX100 3 Transmission Procedure
3.2 Outline
The last ACK (N)
0x03
0x0020
0x02
“YERC”
0x01
0x0000
0x03
0x95
0x8000_000N
“99999999”
0x00 0x00 0x00
0x0000 0x0000
<Format>
Identifier
Header part size
Reserve 1 Processing division
Data part size
ACK Request ID
Service
Block No.
Reserve 2
Status
Added status
Added status size
Padding
Padding
3-12
HW1480958
31 of 119
DX100
162529-1CD
3 Transmission Procedure
3.2 Outline
3.2.5 File Control (File list)
UDP: optional
PC Socket opened
Request 1 (request of llist)
Data 1 (file list 1)
ACK 1 (reply of confirmation)
Data 2 (file list 2)
ACK 2 (reply of confirmation)
The last data (file list N: the last file list)
ACK N (reply of confirmation)
Socket closed
UDP:10041
DX100
Request 1
0x03
0x0020
0x02
“YERC”
0x00
0x0005
0x04
0x0000_0000
“99999999”
0x00
*
I
0x00
0x32
.
J
0x0000
0x0000
B
<Format>
Identifier
Header part size
Reserve 1 Processing division
Block No.
Data part size
ACK Request ID
Reserve 2
Command No.
Instance
Attribute Service Padding
File identification (refer to data details)
Data 1
0x03
0x0020
0x02
“YERC”
0x01
0x01d?
0x04
0xB2
0x0000_0001
“99999999”
0x00 0x00 0x00
0x0000 0x0000
File list 1
<Format>
Identifier
Header part size
Reserve 1 Processing division
Block No.
Data part size
ACK Request ID
Service
Reserve 2
Status Added status size
Padding
Added status Padding
File list 1 (refer to “Details of data”)
3-13
HW1480958
32 of 119
162529-1CD
DX100 3 Transmission Procedure
3.2 Outline
ACK1
0x03
0x0020
0x02
“YERC”
0x01
0x0000
0x04
0x00
0x0000_0001
“99999999”
0x00
0x32
0x0000
0x0000
<Format>
Identifier
Header part size
Reserve 1 Processing division
Data part size
ACK Request ID
Command No.
Attribute Service
Block No.
Reserve 2
Instance
Padding
Data 2
0x03
0x0020
0x02
“YERC”
0x01
0x01d?
0x04
0xB2
0x0000_0002
“99999999”
0x00 0x00 0x00
0x0000 0x0000
File list 2
<Format>
Identifier
Header part size
Reserve 1 Processing division
Block No.
Data part size
ACK Request ID
Service
Reserve 2
Status Added status size
Added status
Padding
Padding
File list 2
ACK2
0x03
0x0020
0x02
“YERC”
0x01
0x0000
0x04
0x00
0x0000_0002
“99999999”
0x00
0x32
0x0000
0x0000
<Format>
Identifier
Header part size
Reserve 1 Processing division
Data part size
ACK Request ID
Command No.
Attribute Service
Block No.
Reserve 2
Instance
Padding
3-14
HW1480958
33 of 119
162529-1CD
DX100 3 Transmission Procedure
3.2 Outline
The last data (N)
“YERC”“YERC”
0x03
0x0020
0x02 0x01
0x0008
0x04
0xB2
0x8000_000N
“99999999”
0x00 0x00 0x00
0x0000 0x0000
File list N
<Format>
Identifier
Header part size
Reserve 1 Processing division
Data part size
ACK Request ID
Block No.
Reserve 2
Service Status
Added status
Added status size
Padding
Padding
File list N
The last ACK (N)
0x03
0x0020
0x02
“YERC”
0x01
0x0000
0x04
0x8000_000N
“99999999”
0x00
0x00
0x32
0x0000
0x0000
<Format>
Identifier
Header part size
Reserve 1 Processing division
Block No.
Data part size
ACK Request ID
Reserve 2
Command No.
Attribute Service
Instance
Padding
3-15
HW1480958
34 of 119
162529-1CD
DX100 3 Transmission Procedure
3.2 Outline
Detail of data
Not specified
*.*
*.JBI
*.DAT
*.CND
*.PRM
*.SYS
*.LST
JBI list
JBI list
JBI list
DAT file list
CND file list
PRM file list
SYS file list
LST file list
Output form of the list
The list is described in the form of “file name” + <CR> + <LF>
consecutively
‘I’
‘3’
‘B’
‘4’
<Ex.>
‘1’
‘I’
‘2’
‘.’
<CR>
‘.’
<CR>
‘.’
<CR>
‘3’
‘I’
‘4’
‘J’
<LF>
‘J’
<LF>
‘J’
<LF>
‘.’
<CR>
‘4’
‘B’
‘B’
‘2’
‘B’
‘3’
‘J’
<LF>
‘4’
‘I’
<CR><LF> means end-of -line
<CR> : Carriage Return
<LF> : Line Feed
3-16
HW1480958
35 of 119
DX100
162529-1CD
3 Transmission Procedure
3.2 Outline
3.2.6 File Control (Deleting of file)
PC
UDP: optional
Socket opened
Request 1 (request of llist)
ACK 1 (reply of confirmation)
Socket closed
UDP:10041
DX100
Request 1
0x03
0x0020
0x02
“YERC”
0x01
0x000B
0x05
0x0000_0000
“99999999”
0x00
T
J
J
0x00
0x09
E
O
B
S
B
I
0x0000
0x00
T
.
<Format>
Identifier
Header part size
Reserve 1 Processing division
Data part size
ACK Request ID
Command No.
Attribute Service
Block No.
Reserve 2
File name
Instance
Padding
ACK 1
0x03
0x0020
0x02
‘YERC’
0x01
0x0000
0x05
0x89
0x8000_0000
“99999999”
0x00 0x00 0x00
0x0000 0x0000
<Format>
Identifier
Header part size
Reserve 1 Processing division
Data part size
ACK Request ID
Service
Block No.
Reserve 2
Status
Added status
Added status size
Padding
Padding
3-17
HW1480958
36 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3
Respective Commands for Robot Control
Follows are robot controlling commands which can use in the high-speed
Ethernet communication.
Table 3-1: List of Robot Control Command
No. Command
3
4
1
2
No.
0x70
0x71
7
8
5
6
0x72
0x73
0x74
0x75
0x76
0x77
9 0x78
10 0x79
11 0x7A
12 0x7B
13 0x7C
14 0x7D
15 0x7E
16 0x7F
17 0x80
18 0x81
19 0x82
20 0x83
21 0x84
22 0x85
23 0x86
24 0x87
25 0x88
26 0x89
27 0x300
28 0x301
29 0x302
30 0x303
31 0x304
32 0x305
33 0x306
34 0x307
Name Reference chapter
Alarm data reading command
Alarm history reading command
Status information reading command
Executing job information reading command
Axis configuration information reading command
Robot position data reading command
Position error reading command
Torque data reading command
Refer to
Refer to
Refer to
Refer to
Refer to
Refer to
Refer to
Refer to
I/O data reading / writing command
Register data reading / writing command
Byte variable (B) reading / writing command
Integer type variable (I) reading / writing command
Double precision integer type variable (B) reading / writing command
Refer to
Refer to
Refer to
Refer to
Refer to
Real type variable (R) reading / writing command
Character type variable (S) reading / writing command
Refer to
Refer to
Robot position type variable (P) reading / writing command Refer to
Base position type variable (BP) reading / writing command
Refer to
External axis type variable (EX) reading / writing command Refer to
Alarm reset / error cancel command
HOLD / servo ON/OFF command
Step / cycle / continuous switching command
Refer to
Refer to
Refer to
Refer to
Character string display command to the programming pendant
Start-up (job START) command
Job select command
Management time acquiring command
System information acquiring command
Plural I/O data reading / writing command
Plural register data reading / writing command
Refer to
Refer to
Refer to
Refer to
Refer to
Refer to
Plural byte type variable (B) reading / writing command Refer to
Plural integer type variable (I) reading / writing command Refer to
Refer to
Plural double precision integer type variable (B) reading / writing command
Plural real type variable (R) reading / writing command Refer to
Refer to
Plural character type variable (S) reading / writing command
Plural robot position type variable (P) reading / writing command
Refer to
3-18
HW1480958
37 of 119
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Table 3-1: List of Robot Control Command
No. Command
No.
35 0x308
Name
36
37
38
39
40
0x309
0x30A
0x30B
0x8A
0x8B
Plural base position type variable (BP) reading / writing command
Plural external axis type variable (EX) reading / writing command
Alarm data reading command
(for applying the sub code character strings)
1)
Alarm history reading command
(for applying the sub character strings)
Move instruction command
(Type Cartesian coordinates)
Move instruction command
1 This command is available for system software version DS3.00 or higher.
Reference chapter
162529-1CD
3-19
HW1480958
38 of 119
162529-1CD
DX100
Command No.
Instance
Attribute
Service
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.1 Alarm Data Reading Command
Request
Sub header part
<Details>
0x70
Specify one out of followings
1: The latest alarm
2: The second alarm from the
latest
3: The third alarm from the latest
4: The fourth alarm from the latest
Specify one out of followings
1: Alarm code
2: Alarm data
3: By alarm type
4: Alarm occurring time
5: Alarm character string name
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
Up to four alarms are displayed on the P.P display at the same time. Specify one out of them.
Alarm code means the alarm No.
Alarm data means the sub code which supports the alarm contents. Some alarms may not appear as the sub code.
Specify the accessing method to the data.
0x0E: Read out data of the specified element number
0x01: Read out data of all the element number
(In this case, specify0 to the element number.)
Data part
No data part
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: not specified
•
1: 1 WORD
•
2: 2 WORD
Error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-20
HW1480958
39 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
11
12
13
14
15
7
8
9
10
5
6
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1 Alarm code Range is from 0x0001 to 0x270F(decimal value: 9999)
2 Alarm data
3 Alarm type
Setting values vary in accordance with the contents of the alarm type. Also, some alarms are not displayed with the sub code. In this case, the value is zero (0x0).
0 : No alarm
1 : Decimal UNSIGNED SHORT type
(display example: [1])
2 : UNSIGNED CHAR bit pattern
(display example: [0000_0001])
3 : User axis type (display example: [SLURBT])
4 : Spacial coordinate type (display example: [XYZ])
5 : Robot coordinate type
(display example: [XYZRxRyRz])
6 : Conveyor characteristic file (display example: [123])
8 : Control group type
(display example: [R1R2S1S2])
robot & station
9 : Decimal SHORT type (display example: [-1])
10 : UNSIGNED SHORT bit pattern
(display example: [0000_0000_0000_0001])
11 : Control group type (display example: [R1])
for robot only
12 : Control group type (display example:[R1S1B1])
for robot, station and base
20 : Control group LOW/HIGH logical axis
(display example: [R1:LOW SLURBT, HIGH
SLURBT])
21 : Control group MIN/MAX logical axis
(display example: [R1: MIN SLURBT, MAX
SLURBT])
22 : Control group MIN/MAX spacial coordinate
(display example: [R1: MIN XYZ, MAX XYZ])
23 : Logical axis of both control group 1 and control
group 2
(display example: [R1: SLURBT, R2: SLURBT])
24 : Logical axis 1 and 2 of the control group
(display example: [R1: SLURBT, SLURBT])
25 : Logical axis of the control group and UNSIGNED
CHAR type
(display example: [R1: SLURBT, 1])
27 : Control group and UNSIGNED CHAR type
(display example: [R1: 1])
4 Alarm occurring time
(Character strings of 16 letters)
Ex.2011/10/10 15:49
Alarm character strings name
(character strings: 32 letters)
It is transmitted in the form of the character strings whose language code was selected by the programming pendant and half- and full-width characters are mixed.
3-21
HW1480958
40 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
NOTE
For the alarm character strings name, it is transmitted in the form of the character strings whose language code was selected by the programming pendant.
Use the same language code as the DX100, or the characters corrupt in case the client side dose not correspond to its language code.
3-22
HW1480958
41 of 119
DX100
Command No.
Instance
Attribute
Service
162529-1CD
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.2 Alarm History Reading Command
Request
Sub header part
<Details>
0x71
Specify one out of followings
•
1 to 100
•
1001 to 1100
•
2001 to 2100
•
3001 to 3100
•
4001 to 4100
Specify one out of followings
1: Alarm code
2: Alarm data
3: Alarm type
4: Alarm occurring time
5: Alarm character strings name
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
Specify the alarm number
1 to 100 : Major failure
1001 to 1100: Monitor alarm
2001 to 2100: User alarm (system)
3001 to 3100: User alarm (user)
4001 to 4100: OFF line alarm
Alarm code means the alarm No.
Alarm data means the sub code which supports the alarm content. There are some cases that the sub code for the occurring alarm would not appear.
Specify the accessing method to the data.
0x0E: Read out data of the specified element number
0x01: Read out data of all the element number
(In this case, specify0 to the element number.)
Data part
No data part
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: not specified
•
1: 1 WORD
•
2: 2 WORD
Error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-23
HW1480958
42 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
11
12
13
14
15
7
8
9
10
5
6
32bit Integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1 Alarm code Range is from 0x0001 to 0x270F(decimal value: 9999)
2 Alarm data
3 Alarm type
Setting values vary in accordance with the contents of the alarm type. Also, some alarm are not displayed with the sub code. In this case, the value is 0 :0x0).
0 : No alarm
1 : Decimal UNSIGNED SHORT type
(display example: [1])
2 : UNSIGNED CHAR bit pattern
(display example: [0000_0001])
3 : User axis type (display example: [SLURBT])
4 : Spacial coordinate type (display example: [XYZ])
5 : Robot coordinate type
(display example: [XYZRxRyRz])
6 : Conveyor characteristic file (display example: [123])
8 : Control group type
(display example: [R1R2S1S2])
robot & station
9 : Decimal SHORT type (display example: [-1])
10 : UNSIGNED SHORT bit pattern
(display example: [0000_0000_0000_0001])
11 : Control group type (display example: [R1])
for robot only
12 : Control group type (display example:[R1S1B1])
for robot, station and base
20 : Control group LOW/HIGH logical axis
(display example: [R1: LOW SLURBT, HIGH
SLURBT])
21 : Control group MIN/MAX logical axis
(display example: [R1: MIN SLURBT, MAX
SLURBT])
22 : Control group MIN/MAX spacial coordinate
(display example: [R1: MIN XYZ, MAX XYZ])
23 : Logical axis of both control group 1 and control
group 2
(display example: [R1: SLURBT, R2: SLURBT])
24 : Logical axis 1 and 2 of the control group
(display example: [R1:SLURBT, SLURBT])
25 : Logical axis of the control group and UNSIGNED
CHAR type
(display example: [R1: SLURBT, 1])
27 : Control group and UNSIGNED CHAR type
(display example: [R: 1])
4 Alarm occurring time
(Character strings of 16 letters)
Ex.2011/10/10 15:49
Alarm character strings name
(character strings: 32 letters)
It is transmitted in the form of the character strings whose language code was selected by the programming pendant and half- and full-width characters are mixed.
3-24
HW1480958
43 of 119
DX100
162529-1CD
3 Transmission Procedure
3.3 Respective Commands for Robot Control
NOTE
For the alarm character strings name, it is transmitted in the form of the character strings whose language code was selected by the programming pendant.
Use the same language code as the DX100, or the characters corrupt in case the client side dose not correspond to its language code.
3-25
HW1480958
44 of 119
162529-1CD
DX100
Command No.
Instance
Attribute
Service
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.3 Status Information Reading Command
Request
Sub header part
<Details>
0x72
Fixed to “1”.
Specify one out of followings
1: Data 1
2: Data 2
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
Specify “1”.
Specify the status data number.
For the details of Data1 and Data 2, refer to “Details of data”.
Specify the accessing method to the data.
0x0E: Read out data of the specified element number
0x01: Read out data of all the element number
(In this case, specify0 to the element number.)
Data part
No data part
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: not specified
•
1: 1 WORD
•
2: 2 WORD
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1 Data 1 Refer to “Details of data”.
2 Data 2 Refer to “Details of data”.
Data 1 bit0 bit1 bit2 bit3 bit4 bit5 bit6 bit7
Details of data
Step
1 cycle
Automatic and continuous
Running
In-guard safe operation
Teach
Play
Command remote
Data 2 bit0 bit1 bit2 bit3 bit4 bit5 bit6 bit7
In hold status (by programming pendant)
In hold status (externally)
In hold status (by command)
Alarming
Error occurring
Servo ON
3-26
HW1480958
45 of 119
DX100
Command No.
Instance
Attribute
Service
162529-1CD
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.4 Executing Job Information Reading Command
Request
Sub header part
<Details>
0x73
Specify one out of followings
1: Master task
2: Sub task 1
3: Sub task 2
4: Sub task 3
5: Sub task 4
6: Sub task 5
7: Sub task 6
8: Sub task 7
9: Sub task 8
10: Sub task 9
11: Sub task 10
12: Sub task 11
13: Sub task 12
14: Sub task 13
15: Sub task 14
16: Sub task 15
Specify one out of followings
1: Job name
2: Line number
3: Step number
4: Speed override value
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
Specify the status data number of the executing job information.
Specify the accessing method to the data.
0x0E: Read out data of the specified element number
0x01: Read out data of all the element number
(In this case, specify0 to the element number)
Data part
No data part
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 :respond normally
•
Other than 0x00
: respond abnormally
•
0: not specified
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-27
HW1480958
46 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
8
9
6
7
4
5
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1
2
Job name
(character strings: 32 letters)
Job name
Half-width character: 32 characters
Full-width character: 16 characters
3
10
11
Line No. (0 to 9999)
Step No. (1 to 9998)
Speed override value
Job line number
Job step number
Speed override value
NOTE
For the alarm character strings name, it is transmitted in the form of the character strings whose language code was selected by the programming pendant.
Use the same language code as the DX100, or the characters corrupt in case the client side dose not correspond to its language code.
3-28
HW1480958
47 of 119
DX100
Command No.
Instance
Attribute
Service
162529-1CD
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.5 Axis Configuration Information Reading Command
Request
Sub header part
<Details>
0x74
Specify one out of followings
•
•
•
•
•
1 to 8
11 to 18
21 to 44
101 to 108
111 to 118
Specify the control group
1 : R1 to 8 : R8
11 : B1 to 18 : B8
…Robot (pulse value)
…Base (pulse value)
21 : S1 to 44 : S24 …Station (pulse value)
101 : R1 to 108 : R8 …Robot
(cartesian coordinate)
111 : B1 to 118 : B8 …Base
(cartesian coordinate)
Specify one out of followings
1: “Axis name” of the first axis
2: “Axis name” of the second axis
3: “Axis name” of the third axis
4: “Axis name” of the fourth axis
5: “Axis name” of the fifth axis
6: “Axis name” of the sixth axis
7: “Axis name” of the seventh axis
8: “Axis name” of the eighth axis
• Get_Attribute_Single:0x0E
•
Get_Attribute_All: 0x01
Specify the data number of axis information.
Each axis is justified for setting.
“0” is set to nonexistent axis.
Specify the accessing method to the data.
0x0E: Read out data of the specified element number.
0x01: Read out data of all the element number.
(In this case, specify0 to the element number.)
Data part
No data part
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 :respond normally
• Other than 0x00
: respond abnormally
• 0: not specified
•
1: 1 WORD
• 2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-29
HW1480958
48 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1 First coordinate name “S” (R*: pulse)/“X” (R*/B*: cartesian value)/
“1” (B*/S*: pulse)
2 Second coordinate name
3
4
Third coordinate name
Fourth coordinate name
“L” (R*: pulse)/“Y” (R*/B*: cartesian value)/
“2” (B*/S*: pulse)
“U” (R*: pulse)/“Z” (R*/B*: cartesian value)
“3” (B*/S*: pulse)
“R” (R*: pulse)/“Rx” (R*: cartesian value)/
“4” (B*/S*: pulse)
5 Fifth coordinate name
6
7
Sixth coordinate name
Seventh coordinate name
“B” (R*: pulse)/“Ry” (R*: cartesian value)/
“5” (B*/S*: pulse)
“T” (R*: pulse)/“Rz” (R*: cartesian value)/
“6” (B*/S*: pulse)
“E” (R*: pulse)/“Rz” (R*: cartesian value)/
“7” (B*/S*: pulse)
8 Eighth coordinate name
*: Each control group number.
R: Robot (R1 to R8)
S: Station (S1 to s24)
B: Base (B1 to b8)
3-30
HW1480958
49 of 119
DX100
Service
162529-1CD
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.6 Robot Position Data Reading Command
Cartesian value can select the base coordinate only. (It cannot select the robot, user and tool coordinates.)
Request
Sub header part
Command No.
Instance
0x75
Specify one out of followings
•
1 to 8
•
11 to 18
•
21 to 44
•
101 to 108
Attribute Specify one out of followings
1: Data type
2: Form
3: Tool number
4: User coordinate number
5: Extended form
6: First axis data
7: Second axis data
8: Third axis data
9: Fourth axis data
10: Fifth axis data
11: Sixth axis data
12: Seventh axis data
13: Eighth axis data
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
<Details>
Specify the control group
1 : R1 to 8 : R8
11 : B1 to 18 : B8
101 : R1 to 108 : R8
… Robot (pulse value)
… Base (pulse value)
21 : S1 to 44 : S24 … Station (pulse value)
… Robot
(cartesian coordinate)
Specify the position information data number.
1 0: pulse value/16: base coordinate value
2 As for the form, refer to the “Details of data”.
3 Tool number
4 User coordinate number
5 As for the extended form, refer to the “Details of data”.
6 First axis data
7 Second axis data
8 Third axis data
9 Fourth axis data
10 Fifth axis data
11 Sixth axis data
12 Seventh axis data
13 Eighth axis data
Each axis data is output by the same sequence as
mentioned in section 3.3.5 “Axis Configuration
, and “0” is set to nonexistent axis.
Specify the accessing method to the data.
0x0E: Read out data of the specified element number
0x01: Read out data of all the element number
(In this case, specify0 to the element number.)
3-31
HW1480958
50 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
No data part
Form bit0 0: Front bit1 0: Upper arm bit2 0: Flip bit3 0: ө R < 180, bit4 0: ө T<180, bit5 0: ө S<180, bit6 0: Redundant
front
Detail of data
Please refer section 3.9.5 “Flip/ No flip” in the “DX100 OPERATOR’S
MANUAL” prepared for each application.
1: Back 1: ө L ≥ 180
1: Lower arm
1:No flip
1: ө R ≥ 180
1: ө T ≥ 180
1: ө S ≥ 180
1: Redundant
back bit7 0: Previous step regarded reverse
conversion specified
1: Form regarded reverse conversion
specified
Extended form bit0 0: ө L<180, bit1 0: ө U<180, bit2 0: ө B<180, bit3 0: ө E<180, bit4 0: ө W<180, bit5 Reserve bit6 Reserve bit7 Reserve
1:
1:
1:
1: ө U ≥ 180 ө B ≥ 180 ө E ≥ 180 ө W ≥ 180
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-32
HW1480958
51 of 119
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
8
9
10
11
12
13
6
7
4
5
2
3
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1 Data type 0: Pulse value/ 16: Base coordinate value
Form
Tool number
For the form, refer to “Details of data”.
Tool number
User coordinate number
Extended form
First axis data
Second axis data
User coordinate number
For the extended form, refer to “Details of data”.
Third axis data
Fourth axis data
Fifth axis data
Sixth axis data
Seventh axis data
Eighth axis data
162529-1CD
Form bit0 0: Front
Details of data
Please refer “3.9.5 Flip/ No flip” in “DX100 OPERATOR’S MANUAL” prepared for each application.
1: Back bit1 0: Upper arm bit2 0: Flip bit3 0: ө R < 180, bit4 0: ө T<180, bit5 0: ө S<180, bit6 0: Redundant
front
1: Lower arm
1: No flip
1: ө R ≥ 180
1: ө T ≥ 180
1: ө S ≥ 180
1: Redundant
back bit7 0: Previous step regarded reverse
conversion specified
1: Form regarded reverse conversion
specified
Extended form bit0 0: ө L<180, 1: ө L ≥ 180 bit1 0: ө U<180, 1: ө U ≥ 180 bit2 0: ө B<180, 1: ө B ≥ 180 bit3 0: ө E<180, 1: ө E ≥ 180 bit4 0: ө W<180, 1: ө W ≥ 180 bit5 Reserve bit6 Reserve bit7 Reserve
3-33
HW1480958
52 of 119
162529-1CD
DX100
Command No.
Instance
Attribute
Service
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.7 Position Error Reading Command
Request
Sub header part
<Details>
0x76
Specify one out of followings
•
1 to 8
•
11 to 18
•
21 to 44
Specify the control group
1 : R1 to 8 : R8
11 : B1 to 18 : B8
… Robot axis
… Base axis
21 : S1 to 44 : S24 … Station axis
Specify one out of followings
1: First axis data
2: Second axis data
3: Third axis data
4: Fourth axis data
5: Fifth axis data
6: Sixth axis data
7: Seventh axis data
8: Eighth axis data
•
Get_Attribute_Singlel: 0x0E
• Get_Attribute_All:0x01
Specify the axis number.
Each axis data is output by the same sequence as mentioned in
section 3.3.5 “Axis Configuration
Information Reading Command” , and “0” is set to
nonexistent axis.
Specify the accessing method to the data.
0x0E: Read out data of the specified element number
0x01: Read out data of all the element number
(In this case, specify0 to the element number.)
Data part
No data part
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
• 0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
• 1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
5
6
3
4
7
8
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1
2
First axis data
Second axis data
Position variable data of each axis can be read out.
Third axis data
Fourth axis data
Fifth axis data
Sixth axis data
Seventh axis data
Eighth axis data
3-34
HW1480958
53 of 119
DX100
Command No.
Instance
Attribute
Service
162529-1CD
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.8 Torque Data Reading Data
Request
Sub header part
<Details>
0x77
Specify one out of followings
•
1 to 8
•
11 to 18
•
21 to 44
Specify the control group
1 : R1 to 8 : R8
11 : B1 to 18 : B8
… Robot axis
… Base axis
21 : S1 to 44 : S24 … Station axis
Specify one out of followings
1: First axis data
2: Second axis data
3: Third axis data
4: Fourth axis data
5: Fifth axis data
6: Sixth axis data
7: Seventh axis data
8: Eighth axis data
•
Get_Attribute_Single: 0x0E
• Get_Attribute_All:0x01
Specify the axis number.
Each axis data is output by the same sequence as
mentioned in section 3.3.5 “Axis Configuration
, and “0” is set to nonexistent axis.
Specify the accessing method to the data.
0x0E: Read out data of the specified element number
0x01: Read out data of all the element number
(In this case, specify0 to the element number.)
Data part
No data part
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
• 0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
• 1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
5
6
3
4
7
8
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1
2
First axis data
Second axis data
Torque data of each axis can be read out.
Third axis data
Fourth axis data
Fifth axis data
Sixth axis data
Seventh axis data
Eighth axis data
3-35
HW1480958
54 of 119
162529-1CD
DX100
Command No.
Instance
Attribute
Service
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.9 I/O Data Reading / Writing Command
Request
Sub header part
<Details>
0x78
Specify one out of followings
•
1 to 256
•
1001 to 1256
•
2001 to 2256
•
3001 to 3256
•
4001 to 4160
•
5001 to 5200
•
6001 to 6064
•
7001 to 7999
•
2501 to 2756
•
3501 to 3756
•
8001 to 8064
•
8201 to 8220
Fixed to “1”.
•
Get_Attribute_Single: 0x0E
•
Set_Attribute_Single: 0x10
Specify logical number /10
•
1 to 256 : Robot user input
•
1001 to 1256: Robot user output
•
2001 to 2256: External input
•
2501 to 2756: Network input
•
3001 to 3256: External output
•
3501 to 3756: Network output
•
4001 to 4160: Robot system input
•
5001 to 5200: Robot system output
•
6001 to 6064: Interface panel input
•
7001 to 7999: Auxiliary relay
•
8001 to 8064: Robot control status signal
•
8201 to 8220: Pseudo input
Specify “1”.
Specify the accessing method to the data.
0x0E: Read out of all I/O data is enabler
0x01: Only network input signal is writable.
32bit integer Byte 0
1 IO data
Data part
(Data exists during the writing operation only)
Byte 1 Byte 2 Byte3 <Details>
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
32bit integer Byte 0
1 IO data
Data part
(Data exists during the writing operation only)
Byte 1 Byte 2 Byte3 <Details>
I/O data exists only when requested by the client.
3-36
HW1480958
55 of 119
162529-1CD
DX100
Command No.
Instance
Attribute
Service
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.10 Register Data Reading / Writing Command
Request
Sub header part
<Details>
0x79
Specify one out of followings
•
0 to 999
Fixed to “1”.
•
Get_Attribute_Single: 0x0E
•
Set_Attribute_Single: 0x10
Specify the register number
0 to 999 (writable register: 0 to 559)
Specify “1”.
Specify the accessing method to the data.
0x0E: Read out the specified register data
0x01: Register 0 to 599 is writable
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1
Byte 1
Register data
Byte 2 Byte3 <Details>
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1
Byte 1
Register data
Byte 2 Byte3 <Details>
Register data exists only when requested by the client.
3-37
HW1480958
56 of 119
162529-1CD
DX100
Command No.
Instance
Attribute
Service
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.11 Byte Variable (B) Reading / Writing Command
Request
Sub header part
<Details>
0x7A
Specify one out of followings
•
0 to 99 (for standard setting)
Fixed to “1”.
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
•
Set_Attribute_Single: 0x10
•
Set_Attribute_All: 0x02
Specify the variable number.
Since the extended variable is an optional function, follow the numbers of the variables specified by the parameter when specifying the number.
Specify “1”.
Specify the accessing method to the data.
0x0E/0x01: Read out data of the specified element
number
0x10/0x02: Write the data to the specified variable
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1 B variable
Byte 1 Byte 2 Byte3 <Details>
Set the data when writing.
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1 B variable
Byte 1 Byte 2 Byte3 <Details>
The data exists only when requested by the client.
3-38
HW1480958
57 of 119
DX100
Command No.
Instance
Attribute
Service
162529-1CD
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.12 Integer Type Variable (I) Reading / Writing Command
Request
Sub header part
<Details>
0x7B
Specify one out of followings
•
0 to 99 (for standard setting)
Fixed to “1”.
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
•
Set_Attribute_Single: 0x10
•
Set_Attribute_All: 0x02
Specify the variable number.
Since the extended variable is an optional function, follow the numbers of the variables specified by the parameter when specifying the number.
Specify “1”.
Specify the accessing method to the data.
0x0E/0x01: Read out data of the specified element
number
0x10/0x02: Write the data to the specified variable
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1 I variable
Byte 1 Byte 2 Byte3 <Details>
Set the data when writing.
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1 I variable
Byte 1 Byte 2 Byte3 <Details>
The data exists only when requested by the client.
3-39
HW1480958
58 of 119
162529-1CD
DX100
Command No.
Instance
Attribute
Service
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.13 Double Precision Integer Type Variable (B) Reading / Writing
Command
Request
Sub header part
<Details>
0x7C
Specify one out of followings
•
0 to 99 (for standard setting)
Fixed to “1”.
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
•
Set_Attribute_Single: 0x10
•
Set_Attribute_All: 0x02
Specify the variable number.
Since the extended variable is an optional function, follow the numbers of the variables specified by the parameter when specifying the number.
Specify “1”.
Specify the accessing method to the data.
0x0E/0x01: Read out data of the specified element
number
0x10/0x02: Write the data to the specified variable
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1 D variable
Byte 1 Byte 2 Byte3 <Details>
Set the data when writing.
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1 D variable
Byte 1 Byte 2 Byte3 <Details>
The data exists only when requested by the client.
3-40
HW1480958
59 of 119
DX100
Command No.
Instance
Attribute
Service
162529-1CD
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.14 Real Type Variable (R) Reading / Writing Command
Request
Sub header part
<Details>
0x7D
Specify one out of followings
•
0 to 99 (for standard setting)
Fixed to “1”.
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
•
Set_Attribute_Single: 0x10
•
Set_Attribute_All: 0x02
Specify the variable number.
Since the extended variable is an optional function, follow the numbers of the variables specified by the parameter when specifying the number.
Specify “1”.
Specify the accessing method to the data.
0x0E/0x01: Read out data of the specified element
number
0x10/0x02: Write the data to the specified variable
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1 R variable
Byte 1 Byte 2 Byte3 <Details>
Set the data when writing.
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1 R variable
Byte 1 Byte 2 Byte3 <Details>
The data exists only when requested by the client.
3-41
HW1480958
60 of 119
162529-1CD
DX100
Command No.
Instance
Attribute
Service
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.15 Character Type Variable (S) Reading Writing Command
Request
Sub header part
<Details>
0x7E
Specify one out of followings
•
0 to 99 (for standard setting)
Fixed to “1”.
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
•
Set_Attribute_Single: 0x10
•
Set_Attribute_Al: 0x02
Specify the variable number.
Since the extended variable is an optional function, follow the numbers of the variables specified by the parameter when specifying the number
Specify “1”.
Specify the accessing method to the data.
0x0E/0x01: Read out data of the specified element
number
0x10/0x02: Write the data to the specified variable
Data part
(Data exists during the writing operation only)
2
3
32bit integer Byte 0
1 S variable
Byte 1 Byte 2 Byte3 <Details>
Set the data when writing.
4
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
3
4
1
2
32bit integer Byte 0
S variable
Byte 1 Byte 2 Byte3 <Details>
The data exists only when requested by the client.
3-42
HW1480958
61 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.16 Robot Position Type Variable (P) Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x7F
Instance Specify one out of followings
•
0 to 127 (for standard setting)
Attribute
Service
Specify one out of followings
1: Data type
2: Form
3: Tool number
4: User coordinate number
5: Extended form
6: “Coordinated data” of the first axis
7: “Coordinated data” of the second axis
8: “Coordinated data” of the third axis
9: “Coordinated data” of the fourth axis
10: “Coordinated data” of the fifth axis
11: “Coordinated data” of the sixth axis
12: “Coordinated data” of the seventh axis
13: “Coordinated data” of the eighth axis
•
Get_Attribute_All: 0x01
•
Set_Attribute_All: 0x02
Specify the variable number.
Since the extended variable is an optional function, follow the numbers of the variables specified by the parameter when specifying the number.
Specify the axis information data number.
Followings are the data type.
0: Pulse value
16: Base coordinated value
17: Robot coordinated value
18: User coordinated value
19: Tool coordinated value
Specify the accessing method to the data.
0x0E/0x01: Read out data of the specified
element number
0x10/0x02: Write the data to the specified
variable
Data part
(Data exists during the writing operation only)
10
11
12
13
8
9
6
7
4
5
2
3
32bit integer Byte 0
1 Data type
Byte 1 Byte 2 Byte3 <Details>
Form
Tool number
User coordinate number
Extended form
0: Pulse value
16: Base coordinated value
17: Robot coordinated value
18: User coordinated value
19: Tool coordinated value
For the form, refer to “Details of data”.
Tool number
User coordinate number
For the extended form, refer to “Details of data”.
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
3-43
HW1480958
62 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Form bit0 0: Front bit1 0: Upper arm bit2 0: Flip bit3 0: ө R < 180, bit4 0: ө T<180, bit5 0: ө S<180, bit6 0: Redundant
front
Details of data
Please refer “3.9.5 Flip/ No flip” in “DX100 OPERATOR’S MANUAL” prepared for each application.
1: Back 1: ө L ≥ 180
1: Lower arm
1:No flip
1: ө R ≥ 180
1: ө T ≥ 180
1: ө S ≥ 180
1: Redundant
back bit7 0: Previous step regarded reverse
conversion specified
1: Form regarded reverse conversion
specified
Extended form bit0 0: ө L<180, bit1 0: ө U<180, bit2 0: ө B<180, bit3 0: ө E<180, bit4 0: ө W<180, bit5 Reserve bit6 Reserve bit7 Reserve
1:
1:
1:
1: ө U ≥ 180 ө B ≥ 180 ө E ≥ 180 ө W ≥ 180
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-44
HW1480958
63 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
(Data exists during the writing operation only)
10
11
12
13
8
9
6
7
4
5
2
3
32bit integer Byte 0
1 Data type
Byte 1 Byte 2 Byte3 <Details>
0: Pulse value
16: Base coordinated value
17: Robot coordinated value
18: User coordinated value
19: Tool coordinated value
Form
Tool number
User coordinate number
Extended form
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
For the form, refer to “Details of data”.
Tool number
User coordinate number
For the extended form, refer to “Details of data”.
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
Form bit0 0: Front bit1 0: Upper arm bit2 0: Flip bit3 0: ө R<180, bit4 0: ө T<180, bit5 0: ө S<180, bit6 0: Redundant
front
Details of data
Please refer to section 3.9.5 “Flip/ No flip” in “DX100 OPERATOR’S
MANUAL” prepared for each application.
1: Back 1: ө L ≥ 180
1: Lower arm
1:No flip
1: ө R ≥ 180
1: ө T ≥ 180
1: ө S ≥ 180
1: Redundant
back bit7 0: Previous step regarded reverse
conversion specified
1: Form regarded reverse conversion
specified
Extended form bit0 0: ө L<180, bit1 0: ө U<180, bit2 0: ө B<180, bit3 0: ө E<180, bit4 0: ө W<180, bit5 Reserve bit6 Reserve bit7 Reserve
1: ө U ≥ 180
1: ө B ≥ 180
1: ө E ≥ 180
1: ө W ≥ 180
3-45
HW1480958
64 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.17 Base Position Type Variable (Bp) Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x80
Instance
Attribute
Service
Specify one out of followings
•
0 to 127 (for standard setting)
Specify one out of followings
1: Data type
2: “Coordinated data” of the first axis
3: “Coordinated data” of the second axis
4: “Coordinated data” of the third axis
5: “Coordinated data” of the fourth axis
6: “Coordinated data” of the fifth axis
7: “Coordinated data” of the sixth axis
8: “Coordinated data” of the seventh axis
9: “Coordinated data” of the eighth axis
•
Get_Attribute_Single :0x0E
•
Get_Attribute_All :0x01
•
Set_Attribute_Single :0x10
•
Set_Attribute_All :0x02
Specify the variable number.
Since the extended variable is an optional function, follow the numbers of the variables specified by the parameter when specifying the number.
Specify the axis information data number.
Followings are the data type.
0: Pulse value
16: Base coordinated value
Specify the accessing method to the data.
0x0E: Read out the specified data
0x01: Read out the data
0x10: Write a specified data. If it is not an object
element, keep the data previous to writing
operation.
0x02: Write the data
Data part
(Data exists during the writing operation only)
8
9
6
7
4
5
2
3
32bit integer Byte 0
1 Data type
Byte 1 Byte 2 Byte3 <Details>
0: Pulse value
16: Base coordinated value
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
3-46
HW1480958
65 of 119
DX100
Status
Added status size
Added status
162529-1CD
3 Transmission Procedure
3.3 Respective Commands for Robot Control
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
8
9
6
7
4
5
2
3
32bit integer
1
Byte 0
Data type
Byte 1 Byte 2 Byte3 <Details>
0: Pulse value
16: Base coordinated value
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
3-47
HW1480958
66 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.18 External Axis Type Variable (Ex) Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x81
Instance
Attribute
Service
Specify one out of followings
•
0 to 127 (for standard setting)
Specify one out of followings
1: Data type
2: “Coordinated data” of the first axis
3: “Coordinated data” of the second axis
4: “Coordinated data” of the third axis
5: “Coordinated data” of the fourth axis
6: “Coordinated data” of the fifth axis
7: “Coordinated data” of the sixth axis
8: “Coordinated data” of the seventh axis
9: “Coordinated data” of the eighth axis
•
Get_Attribute_Single :0x0E
•
Get_Attribute_All :0x01
•
Set_Attribute_Single :0x10
•
Set_Attribute_All :0x02
Specify the variable number.
Since the extended variable is an optional function, follow the numbers of the variables specified by the parameter when specifying the number.
Specify the axis information data number.
Followings are the data type.
0: Pulse value
Specify the accessing method to the data.
0x0E : Read out the specified data
0x01 : Read out the data
0x10 :Write a specified data. If it is not an object
element, keep the data previous to writing
operation.
0x02 : Write the data
Data part
(Data exists during the writing operation only)
7
8
9
5
6
3
4
1
2
32bit integer Byte 0
Data type
Byte 1 Byte 2 Byte3 <Details>
0: Pulse value
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
3-48
HW1480958
67 of 119
DX100
Status
Added status size
Added status
162529-1CD
3 Transmission Procedure
3.3 Respective Commands for Robot Control
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
7
8
9
5
6
3
4
1
2
32bit integer Byte 0
Data type
Byte 1 Byte 2 Byte3 <Details>
0: Pulse value
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
3-49
HW1480958
68 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.19 Alarm Reset / Error Cancel Command
Request
Sub header part
<Details>
Command No.
0x82
Instance
Attribute
Specify one out of followings
1: Resetting of alarm
2: Cancelling of error
Fixed to “1”.
Service
•
Set_Attribute_Single: 0x10
Specify the type of reset/cancel
1: RESET (resetting of alarm)
2: CANCEL (cancelling of error)
Specify “1”.
Specify the accessing method to the data.
0x10 : Execute the specified request
32bit integer Byte 0
1 Data 1
Data part
(Data exists during the writing operation only)
Byte 1 Byte 2 Byte3 <Details>
Fixed to “1”.
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
No data part
3-50
HW1480958
69 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.20 Hold / Servo On/off Command
Request
Sub header part
<Details>
Command No.
0x83
Instance Specify one out of followings
1: HOLD
2: Servo ON
3: HLOCK
Attribute
Service
Fixed to “1”.
•
Set_Attribute_Single: 0x10
Specify the type of OFF/ON command
1: HOLD
2: Servo ON
3: HLOCK (Refer to “Details of data”.)
Specify “1”.
Specify the accessing method to the data.
0x10 : Execute the specified request
32bit integer Byte 0
1 1:ON
2:OFF
Data part
(Data exists during the writing operation only)
Byte 1 Byte 2 Byte3 <Details>
Specify ON/OFF
Details of data
HLOCK
This data interlocks the P.P and I/O operation system signals. Only the following operations are available while the interlock operation is ON.
• Emergency stop for the programming pendant
• Inputting signals excluding I/O mode switching, external start, external servo ON, cycle switch, inhibit I/O, inhibit PP/PANEL and master calling up.
HLOCK is invalid while the programming pendant is in edit mode or it is file accessing using other functions.
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-51
HW1480958
70 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.21 Step / Cycle / Continuous Switching Command
Request
Sub header part
<Details>
Command No.
0x84
Instance Specify the following
•
2
Attribute
Service
Fixed to “1”.
•
Set_Attribute_Single: 0x10
Specify the type of status switch command
2: CYCLE (switching of STEP/CYCLE/CONTINUE)
Specify “1”.
Specify the accessing method to the data.
0x10 : Execute the specified request
32bit integer Byte 0
1 Data 1
Data part
(Data exists during the writing operation only)
Byte 1 Byte 2 Byte3 <Details>
CYCLE = 1: STEP/2: 1 CYCLE/3:CONTINUE
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
No data part
3-52
HW1480958
71 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.22 Character String Display Command To The Programming Pendant
Request
Sub header part
<Details>
Command No.
0x85
Instance
Attribute
Service
Fixed to “1”.
Fixed to “1”.
•
Set_Attribute_Single: 0x10
Specify “1”.
Specify “1”.
Specify the accessing method to the data.
0x10 : Execute the specified request
Data part
(Data exists during the writing operation only)
7
8
5
6
1
2
3
4
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
Displaying message Set the character strings to be indicated on the programming pendant
Half-width character: 30 characters
Full-width character: 15 characters
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
No data part
NOTE
For the alarm character strings name, it is transmitted in the form of the character strings whose language code was selected by the programming pendant.
Use the same language code as the DX100, or the characters corrupt in case the client side dose not correspond to its language code.
3-53
HW1480958
72 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.23 Start-up (Job Start) Command
Request
Sub header part
<Details>
Command No.
0x86
Instance
Attribute
Service
Fixed to “1”.
Fixed to “1”.
•
Set_Attribute_Single: 0x10
Specify “1”.
Specify “1”.
Specify the accessing method to the data.
0x10 : Execute the specified request
32bit integer Byte 0
1 Data 1
Data part
(Data exists during the writing operation only)
Byte 1 Byte 2 Byte3 <Details>
Fixed to “1”.
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
No data part
3-54
HW1480958
73 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.24 Job Select Command
Request
Sub header part
<Details>
Command No.
0x87
Instance Specify one out of followings
1: Set the executing job
10: Set the master job (task 0)
11: Set the master job (task 1)
12: Set the master job (task 2)
13: Set the master job (task 3)
14: Set the master job (task 4)
15: Set the master job (task 5)
16: Set the master job (task 6)
17: Set the master job (task 7)
18: Set the master job (task 8)
19: Set the master job (task 9)
20: Set the master job (task 10)
21: Set the master job (task 11)
22: Set the master job (task 12)
23: Set the master job (task 13)
24: Set the master job (task 14)
25: Set the master job (task 15)
Attribute
Service
Specify one out of followings
1: Job name
2: Line number (valid only when
executing job setting.)
•
Set_Attribute_All: 0x02
Specify the type.
Specify the setting content.
Specify the accessing method to the data.
0x02: Read out data of all the element number
(In this case, specify0 to the element number.)
Data part
8
9
6
7
4
5
32bit integer Byte 0
1
2
Job name
Byte 1 Byte 2 Byte3
(Character strings: 32 characters)
<Details>
Job name
Half-width character: 32 characters
Full-width character: 16 characters
3
Line number (0 to 9999) Line number
NOTE
For the alarm character strings name, it is transmitted in the form of the character strings whose language code was selected by the programming pendant.
Use the same language code as the DX100, or the characters corrupt in case the client side dose not correspond to its language code.
3-55
HW1480958
74 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
No data part
3-56
HW1480958
75 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.25 Management Time Acquiring Command
Request
Sub header part
<Details>
Command No.
0x88
Instance Specify one out of followings
•
1
•
10
•
11 to 18
•
21 to 44
•
110
•
111 to 118
•
121 to 144
•
210
•
211 to 218
•
221 to 244
•
301 to 308
Attribute
Service
Specify one out of followings
1: Operation start time
2: Elapse time
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
Specify the type of the management time
1 :Control power ON time
10 :Servo power ON time (TOTAL)
11 to 18 :Servo power ON time (R1 to R8)
21 to 44 :Servo power ON time (S1 to S24)
110 :Play back time (TOTAL)
111 to 118 :Play back time (R1 to R8)
121 to 144 :Play back time (S1 to S24)
210 :Motion time (TOTAL)
211 to 218 :Motion time (R1 to R8)
221 to 244 :Motion time (S1 to S24)
301 to 308 :Operation time (application 1 to 8)
Specify the type of the management time
Specify the accessing method to the data.
0x0E : Read out data of the specified element number
0x01 : Read out data of all the element number
(In this case, specify0 to the element number.)
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
5
6
7
1
2
3
4
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
Operation start time
(Character strings: 16 characters)
Ex. 2011/10/10 15:49
Operation start time
Elapse time
(Character strings: 12 characters)
Ex. 000000:00'00
Elapse time
3-57
HW1480958
76 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.26 System Information Acquiring Command
Request
Sub header part
<Details>
Command No.
0x89
Instance Specify one out of followings
•
11 to 18
•
21 to 44
•
101 to 108
Attribute
Service
Specify one out of followings
1: System software version
2: Model name / application
3: Parameter version
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_Al: 0x01
Specify the type of system type.
11 to 18: Type information (R1 to R8)
21 to 44: Type information (S1 to s24)
101 to 108: Application information (application 1 to 8)
Specify the type of system information
Specify the accessing method to the data.
0x0E: :Read out data of the specified element number
0x01 : Read out data of all the element number
(In this case, specify0 to the element number)
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
10
11
12
8
9
6
7
4
5
32bit integer Byte 0
1
2
Byte 1 Byte 2
System software version
Byte3
(Character strings: 24 characters)
Ex. DS2.07.00A. (JP/US) -00
<Details>
3
The same character strings are returned even if either
11 to 18, 21 to 44 or 101 to 108 is specified to the instance in the request sub-header part.
Model name / application
(Character strings: 16 characters)
Ex.
(For model) ES0165D-A0*
(For application) ARC WELDING
The model name is returned when it is R1 to R8, and
NULL character is returned when it is S1 to S24. Also, application name is returned when it is application 1 to
8R.
Parameter version
(Character strings: 8 characters)
Ex. 12.34
R1 to R8: Parameter version
When it is nonexistent control group, it is returned in
NULL characters.
3-58
HW1480958
77 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.27 Plural I/o Data Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x300
Instance
Attribute
Specify one out of followings
•
1 to 256
•
1001 to 1256
•
2001 to 2256
•
3001 to 3256
•
4001 to 4160
•
5001 to 5200
•
6001 to 6064
•
7001 to 7999
•
2501 to 2756
•
3501 to 3756
•
8001 to 8064
•
8201 to 8220
Fixed to “0”.
Service 0x33:Read plural data
0x34:Write plural data
Specify logical number /10
•
1 to 256 : Robot user input
•
1001 to 1256: Robot user output
•
2001 to 2256: External input
•
2501 to 2756: Network input
•
3001 to 3256: External output
•
3501 to 3756: Network output
•
4001 to 4160: Robot system input
•
5001 to 5200: Robot system output
•
6001 to 6064: Interface panel input
•
7001 to 7999: Auxiliary relay
•
8001 to 8064: Robot control status signal
•
8201 to 8220: Pseudo input
Specify “0”.
Specify the accessing method to the data.
0x33: Read out the fixed size specified by the data part.
0x34: Write the fixed size specified by the data part.
Only the network input signal can be writable.
Data part
32bit integer
1
2
120
Byte 0
Number
Byte 1 Byte 2 Byte3 <Details>
Maximum: 474
*It can specify by a multiple of 2 only.
:
I/O data 1 I/O data 2 I/O data 3 I/O data 4 I/O data part is valid only when writing.
Only the number of data is valid when reading.
I/O data
473
I/O data
474
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-59
HW1480958
78 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
(Data exists during the writing operation only)
32bit integer
1
2
120
Byte 0
Number
Byte 1 Byte 2 Byte3 <Details>
Maximum: 474
*It can specify by a multiple of 2 only.
:
I/O data 1 I/O data 2 I/O data 3 I/O data 4 I/O data part is valid only when writing.
Only the number of data is valid when reading.
I/O data 473 I/O data 474
3-60
HW1480958
79 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.28 Plural Register Data Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x301
Instance Specify one out of followings
•
0 to 999
Attribute
Service
Fixed to “0”
0x33 : Read plural data
0x34 : Write plural data
Specify the variable number (the first number with which reading/writing is executed)
0 to 999 (writable register: 0 to 559)
Specify “0”
Specify the accessing method to the data.
0x33: Read out the fixed size specified by the data part.
0x34: Write the fixed size specified by the data part.
Data part
32bit integer Byte 0
1 Number
2
:
Byte 1
Register data 1
120 Register data 237
Byte 2 Byte3
Register data 2
<Details>
Maximum: 237
I/O data part is valid only when writing. Only the number of data is valid when reading.
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1
2
Number
Byte 1
Register data 1
120
:
Register data 237
Byte 2 Byte3
Register data 2
<Details>
Maximum: 237
The data part is valid only when requested by the client.
3-61
HW1480958
80 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.29 Plural Byte Type Variable (B) Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x302
Instance Specify one out of followings
•
0 to 99 (for standard setting)
Attribute
Service
Fixed to “0”.
0x33 : Read plural data
0x34 : Write plural data
Specify the variable number (the first number with which reading/writing is executed)
Follow the numbers of the variable specified by the parameter since the extended variable is an optional function.
Specify “0”.
Specify the accessing method to the data.
0x33: Read out the fixed size specified by the data part.
0x34: Write the fixed size specified by the data part.
32bit integer
1
2
120
Byte 0
Number
Data part
Byte 1
:
B variable 1 B variable 2
B variable 473 B variable 474
Byte 2 Byte3 <Details>
Maximum: 474
*It can specify by a multiple of
2 only.
B variable 3 B variable 4 Variable data part is valid only when writing. Only the number of data is valid when reading.
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-62
HW1480958
81 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
32bit integer Byte 0
1 Number
2
120
B variable 1
Data part
(Data exists during the writing operation only)
Byte 1 Byte 2 Byte3 <Details>
Maximum: 474
*It can specify by a multiple of 2
only. (invalid if specified by other than a multiple of 2)
B variable 2 B variable
3
B variable 4
:
B variable 473 B variable 474
3-63
HW1480958
82 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.30 Plural Integer Type Variable (I) Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x303
Instance Specify one out of followings
•
0 to 99 (for standard setting)
Attribute
Service
Fixed to “0”
0x33 : Read plural data
0x34 : Write plural data
Specify the variable number (the first number with which reading/writing is executed)
Follow the numbers of the variable specified by the parameter since the extended variable is an optional function.
Specify “0”
Only batch access of all elements is valid
Specify the accessing method to the data.
0x33: Read plural data.
0x34: Write plural data
32bit integer Byte 0
1
2
Number
I variable 1
:
120 I variable 237
Data part
Byte 1 Byte 2
I variable 2
Byte3 <Details>
Maximum: 237
Variable data part is valid only when writing. Only the number of data is valid when reading.
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
32bit integer Byte 0
1
2
Number
I variable 1
120
:
I variable 237
Data part
(Data exists during the writing operation only)
Byte 1 Byte 2 Byte3 <Details>
Maximum: 237
I variable 2
3-64
HW1480958
83 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.31 Plural Double Precision Integer Type Variable (B) Reading / Writing
Command
Request
Sub header part
<Details>
Command No.
0x304
Instance Specify one out of followings
•
0 to 99 (for standard setting)
Attribute
Service
Fixed to “0”
0x33 : Read plural data
0x34 : Write plural data
Specify the variable number (the first number with which reading/writing is executed)
Follow the numbers of the variable specified by the parameter since the extended variable is an optional function.
Specify “0”
Only batch access of all elements is valid
Specify the accessing method to the data.
0x33: Read plural data
0x34: Write plural data
32bit integer Byte 0
1
2
Number
D variable 1
:
Data part
Byte 1
119 D variable 118
Byte 2 Byte3 <Details>
Maximum: 118
Variable data part is valid only when writing. Only the number of data is valid when reading.
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1
2
Number
D variable 1
119
:
D variable 118
Byte 1 Byte 2 Byte3 <Details>
Maximum: 118
3-65
HW1480958
84 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.32 Plural Real Type Variable (R) Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x305
Instance Specify one out of followings
•
0 to 99 (for standard setting)
Attribute
Service
Fixed to “0”
0x33 : Read plural data
0x34 : Write plural data
Specify the variable number (the first number with which reading/writing is executed)
Follow the numbers of the variable specified by the parameter since the extended variable is an optional function.
Specify “0”
Only batch access of all elements is valid
Specify the accessing method to the data.
0x33: Read plural data
0x34: Write plural data
32bit integer Byte 0
1
2
Number
R variable 1
:
Data part
Byte 1
119 R variable 118
Byte 2 Byte3 <Details>
Maximum: 118
Variable data part is valid only when writing. Only the number of data is valid when reading.
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1
2
Number
R variable 1
119
:
R variable 118
Byte 1 Byte 2 Byte3 <Details>
Maximum: 118
3-66
HW1480958
85 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.33 Plural Character Type Variable (S) Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x306
Instance Specify one out of followings
•
0 to 99 (for standard setting)
Attribute
Service
Fixed to “0”
0x33 : Read plural data
0x34 : Write plural data
Specify the variable number (the first number with which reading/writing is executed)
Follow the numbers of the variable specified by the parameter since the extended variable is an optional function.
Specify “0”
Only batch access of all elements is valid
Specify the accessing method to the data.
0x33: Read plural data
0x34: Write plural data
Data part
114
115
116
117
3
4
5
32bit integer Byte 0
1
2
Number
S variable 1
:
S variable 29
Byte 1 Byte 2 Byte3 <Details>
Maximum: 29
Variable data part is valid only when writing.
Only the number of data is valid when reading.
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-67
HW1480958
86 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
(Data exists during the writing operation only)
114
115
116
117
4
5
2
3
32bit integer Byte 0
1 Number
S variable 1
:
S variable 29
Byte 1 Byte 2 Byte3 <Details>
Maximum: 29
3-68
HW1480958
87 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.34 Plural Robot Position Type Variable (P) Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x307
Instance Specify one out of followings
•
0 to 127 (for standard setting)
Attribute
Service
Fixed to “0”
0x33 : Read plural data
0x34 : Write plural data
Specify the variable number (the first number with which reading/writing is executed)
Follow the numbers of the variable specified by the parameter since the extended variable is an optional function.
Specify “0”
Only batch access of all elements is valid
Specify the accessing method to the data.
0x33: Read plural data
0x34: Write plural data
32bit integer Byte 0
1
2 to 14
Number
Data type
Data part
Byte 1 Byte 2 Byte3 <Details>
Maximum: 9
0: Pulse value
16: Base coordinated value
17: Robot coordinated value
18: User coordinated value
19: Tool coordinated value
Form
Tool number
User coordinate number
106 to 118
Form
Tool number
User coordinate number
Extended form
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
:
Data type
Variable data part is valid only when writing.
Only the number of data is valid when reading.
0: Pulse value
16: Base coordinated value
17: Robot coordinated value
18: User coordinated value
19: Tool coordinated value
Form
Tool number
User coordinate number
Form
Tool number
User coordinate number
Extended form
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
3-69
HW1480958
88 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
32bit integer Byte 0
1
2 to 14
Number
Data type
106 to 118
Form
Tool number
User coordinate number
Extended form
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
:
Data type
Data part
(Data exists during the writing operation only)
Byte 1 Byte 2 Byte3 <Details>
Maximum: 9
0: Pulse value
16: Base coordinated value
17: Robot coordinated value
18: User coordinated value
19: Tool coordinated value
Form
Tool number
User coordinate number
Variable data part is valid only when writing.
Only the number of data is valid when reading.
0: Pulse value
16: Base coordinated value
17: Robot coordinated value
18: User coordinated value
19: Tool coordinated value
Form
Tool number
User coordinate number
Form
Tool number
User coordinate number
Extended form
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
3-70
HW1480958
89 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.35 Plural Base Position Type Variable (Bp) Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x308
Instance Specify one out of followings
•
0 to 127 (for standard setting)
Attribute
Service
Fixed to “0”.
0x33 : Read plural data
0x34 : Write plural data
Specify the variable number (the first number with which reading/writing is executed)
Follow the numbers of the variable specified by the parameter since the extended variable is an optional function.
Specify “0”.
Specify the accessing method to the data.
0x33: Read plural data
0x34: Write plural data
Data part
32bit integer Byte 0
1 Number
2
(Replying data is determined by the value specified by the element number.)
Data type
Byte 1
First coordinate data
Third coordinated data
Fourth coordinate data
Byte 2
Second coordinate data
119
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
:
Data type
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
Byte3 <Details>
Maximum: 13
0x00 : Pulse value
0x10 : Base coordinate value
Variable data part is valid only when writing.
Only the number of data is valid when reading.
0x00 : Pulse value
0x10 : Base coordinate value
3-71
HW1480958
90 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1
2 to 10
(Replying data is determined by the value specified by the element number.)
Number
Data type
Byte 1
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
119
Sixth coordinate data
Seventh coordinate data
:
Eighth coordinate data
Data type
Byte 2 Byte3 <Details>
Maximum: 13
0x00 : Pulse value
0x10 : Base coordinate
Variable data part is valid only when writing.
Only the number of data is valid when reading.
0x00 : Pulse value
0x10 : Base coordinate
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
3-72
HW1480958
91 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.36 Plural External Axis Type Variable (Ex) Reading / Writing Command
Request
Sub header part
<Details>
Command No.
0x309
Instance Specify one out of followings
•
0 to 127 (for standard setting)
Attribute
Service
Fixed to “0”
0x33 : Read plural data
0x34 : Write plural data
Specify the variable number (the first number with which reading/writing is executed)
Follow the numbers of the variable specified by the parameter since the extended variable is an optional function.
Specify “0”.
Specify the accessing method to the data.
0x33: Read plural data
0x34: Write plural data
Data part
32bit integer Byte 0
1 Number
2 to 10 Data type
Byte 1
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
110 to 118
Sixth coordinate data
Seventh coordinate data
:
Eighth coordinate data
Data type
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
Byte 2 Byte3 <Details>
Maximum: 13
0 : Pulse value
Variable data part is valid only when writing.
Only the number of data is valid when reading.
0 : Pulse value
3-73
HW1480958
92 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
(Data exists during the writing operation only)
32bit integer Byte 0
1
2 to 10
Number
Data type
Byte 1
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
110 to 118
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
:
Data type
First coordinate data
Second coordinate data
Third coordinated data
Fourth coordinate data
Fifth coordinate data
Sixth coordinate data
Seventh coordinate data
Eighth coordinate data
Byte 2 Byte3 <Details>
Maximum: 13
0: Pulse value
Variable data part is valid only when writing.
Only the number of data is valid when reading.
0: Pulse value
3-74
HW1480958
93 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.37 Alarm Data Reading Command (for Applying the Sub Code
Character Strings)
Request
Sub header part
<Details>
Command No.
0x30A
Instance
Attribute
Specify one out of followings
1: The latest alarm
2: The second alarm from the
latest
3: The third alarm from the latest
4: The fourth alarm from the
latest
Specify one out of followings
1: Alarm code
2: Alarm data
3: By alarm type
4: Alarm occurring time
5: Alarm character string name
6: Sub code data additional
information character strings
7:Sub code data character strings
8:Sub code data character strings
reverse display information
Service
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
Up to four alarms are displayed on the P.P display at the same time. Specify one out of them.
Alarm code means the alarm No.
Alarm data means the sub code which supports the alarm contents. Some alarms may not appear as the sub code.
Sub code additional info character strings means the number for alarms from the Servo circuit board [SV#*]or the function safety board[NSU(CPU#*)]. (*denotes number)
Sub code data character string reverse display information sets [1], when the characters are reverse.
Specify the accessing method to the data.
0x0E: Read out data of the specified element number
0x01: Read out data of all the element number
(In this case, specify0 to the element number.)
Status
Added status size
Added status
Data part
No data part
Answer
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: not specified
•
1: 1 WORD
•
2: 2 WORD
Error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-75
HW1480958
94 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1 Alarm code Range is from 0x0001 to 0x270F(decimal value: 9999)
2 Alarm data
3 Alarm type
Setting values vary in accordance with the contents of the alarm type. Also, some alarms are not displayed with the sub code. In this case, the value is zero (0x0).
0 : No alarm
1 : Decimal UNSIGNED SHORT type
(display example: [1])
2 : UNSIGNED CHAR bit pattern
(display example: [0000_0001])
3 : User axis type (display example: [SLURBT])
4 : Spacial coordinate type (display example: [XYZ])
5 : Robot coordinate type
(display example: [XYZRxRyRz])
6 : Conveyor characteristic file (display example: [123])
8 : Control group type
(display example: [R1R2S1S2])
robot & station
9 : Decimal SHORT type (display example: [-1])
10 : UNSIGNED SHORT bit pattern
(display example: [0000_0000_0000_0001])
11 : Control group type (display example: [R1])
for robot only
12 : Control group type (display example:[R1S1B1])
for robot, station and base
20 : Control group LOW/HIGH logical axis
(display example: [R1:LOW SLURBT, HIGH
SLURBT])
21 : Control group MIN/MAX logical axis
(display example: [R1: MIN SLURBT, MAX
SLURBT])
22 : Control group MIN/MAX spacial coordinate
(display example: [R1: MIN XYZ, MAX XYZ])
23 : Logical axis of both control group 1 and control
group 2
(display example: [R1: SLURBT, R2: SLURBT])
24 : Logical axis 1 and 2 of the control group
(display example: [R1: SLURBT, SLURBT])
25 : Logical axis of the control group and UNSIGNED
CHAR type
(display example: [R1: SLURBT, 1])
27 : Control group and UNSIGNED CHAR type
(display example: [R1: 1])
4 to 7
8 to 15
16 to 19
20 to 43
Alarm occurring time
(Character strings of 16 letters)
Ex.2011/10/10 15:49
Alarm character strings name
(character strings: 32 letters)
Sub code data additional information character strings
(Character strings of 16 letters)
Sub code data character strings
(Character strings of 96 letters)
It is transmitted in the form of the character strings whose language code was selected by the programming pendant and half- and full-width characters are mixed.
[SV#1] indicates the servo board number 1.
[NSU(CPU#1)] indicates that an alarm is found in the function safety unit CPU#1.
44 to 67 Sub code data character strings reverse display information
(Character strings of 96 letters)
Regular characters show [0] and reverse characters show [1]. (display example: [ R1 R2S1S2])
3-76
HW1480958
95 of 119
DX100
162529-1CD
3 Transmission Procedure
3.3 Respective Commands for Robot Control
NOTE
For the alarm character strings name, it is transmitted in the form of the character strings whose language code was selected by the programming pendant.
Use the same language code as the DX100, or the characters corrupt in case the client side dose not correspond to its language code.
3-77
HW1480958
96 of 119
162529-1CD
DX100
Command No.
Instance
Attribute
Service
3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.38 Alarm History Reading Command (for Applying the Sub Code
Character Strings)
Request
Sub header part
<Details>
0x30B
Specify one out of followings
•
•
•
•
•
1 to 100
1001 to 1100
2001 to 2100
3001 to 3100
4001 to 4100
Specify the alarm number
1 to 100 : Major failure
1001 to 1100: Monitor alarm
2001 to 2100: User alarm (system)
3001 to 3100: User alarm (user)
4001 to 4100: OFF line alarm
Specify one out of followings
1:Alarm code
2:Alarm data
3:Alarm type
4:Alarm occurring time
5:Alarm character strings name
6:Sub code data additional
information character strings
7:Sub code data character strings
8:Sub code data character strings
reverse display information
•
Get_Attribute_Single: 0x0E
•
Get_Attribute_All: 0x01
Alarm code means the alarm No.
Alarm data means the sub code which supports the alarm content. Some alarms may not appear as the sub code.
Sub code additional info character strings mean the number for alarms from the Servo circuit board [SV#*]or the function safety board [NSU(CPU#*)].
Sub code data character strings reverse display information means setting [1], when the characters are reverse.
Specify the accessing method to the data.
0x0E: Read out data of the specified element number
0x01: Read out data of all the element number
(In this case, specify0 to the element number.)
Status
Added status size
Added status
Data part
No data part
Answer
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: not specified
•
1: 1 WORD
•
2: 2 WORD
Error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-78
HW1480958
97 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1 Alarm code Range is from 0x0001 to 0x270F(decimal value: 9999)
2 Alarm data
3 Alarm type
Setting values vary in accordance with the contents of the alarm type. Also, some alarms are not displayed with the sub code. In this case, the value is zero (0x0).
0 : No alarm
1 : Decimal UNSIGNED SHORT type
(display example: [1])
2 : UNSIGNED CHAR bit pattern
(display example: [0000_0001])
3 : User axis type (display example: [SLURBT])
4 : Spacial coordinate type (display example: [XYZ])
5 : Robot coordinate type
(display example: [XYZRxRyRz])
6 : Conveyor characteristic file (display example: [123])
8 : Control group type
(display example: [R1R2S1S2])
robot & station
9 : Decimal SHORT type (display example: [-1])
10 : UNSIGNED SHORT bit pattern
(display example: [0000_0000_0000_0001])
11 : Control group type (display example: [R1])
for robot only
12 : Control group type (display example:[R1S1B1])
for robot, station and base
20 : Control group LOW/HIGH logical axis
(display example: [R1:LOW SLURBT, HIGH
SLURBT])
21 : Control group MIN/MAX logical axis
(display example: [R1: MIN SLURBT, MAX
SLURBT])
22 : Control group MIN/MAX spacial coordinate
(display example: [R1: MIN XYZ, MAX XYZ])
23 : Logical axis of both control group 1 and control
group 2
(display example: [R1: SLURBT, R2: SLURBT])
24 : Logical axis 1 and 2 of the control group
(display example: [R1: SLURBT, SLURBT])
25 : Logical axis of the control group and UNSIGNED
CHAR type
(display example: [R1: SLURBT, 1])
27 : Control group and UNSIGNED CHAR type
(display example: [R1: 1])
4 to 7
8 to 15
16 to 19
20 to 43
Alarm occurring time
(Character strings of 16 letters)
Ex.2011/10/10 15:49
Alarm character strings name
(character strings: 32 letters)
Sub code data additional information character strings
(Character strings of 16 letters)
Sub code data character strings
(Character strings of 96 letters)
It is transmitted in the form of the character strings whose language code was selected by the programming pendant and half- and full-width characters are mixed.
[SV#1] indicates the servo board number 1.
[NSU(CPU#1)] indicates that an alarm is found in the function safety unit CPU#1.
44 to 67 Sub code data character strings reverse display information
(Character strings of 96 letters)
Regular characters show [0] and reverse characters show [1]. (display example: [ R1 R2S1S2])
3-79
HW1480958
98 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
NOTE
For the alarm character strings name, it is transmitted in the form of the character strings whose language code was selected by the programming pendant.
Use the same language code as the DX100, or the characters corrupt in case the client side dose not correspond to its language code.
3-80
HW1480958
99 of 119
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.39 Move instruction command (Type Cartesian coordinates)
Request
Sub header part
162529-1CD
<Details>
Command No.
0x8A
Instance Specify one out of followings
1:Link absolute position operation
2:Straight absolute position operation
3:Straight increment value operation
Attribute Fixed to “1”
Service
•
Set_Attribute_All: 0x02
Specify the operation number from one to three.
1:Link absolute position operation
2:Straight absolute position operation
3:Straight increment value operation
Specify “1”.
Specify the accessing method to the data.
0x02: Write the data to the specified coordinate.
3-81
HW1480958
100 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
13
14
15
16
17
18
2
3
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1 Specifying control group (Robot) 1 to 8 (Robot No.)
4
5
6
7
8
9
10
11
12
Specifying control group (Station) 1 to 24 (Station No.)
Specifying the classification in speed Specify the classification of operations
0: % (Link operation)
1: V (Cartesian operation)
2: VR (Cartesian operation)
Specifying a speed Specify the rate
Link operation : 0.01%
Cartesian operation V speed : 0.1 mm/s
Cartesian operation VR speed : 0.1 degree/s
Specifying the operation coordinate Specify the operation coordinate
16: Base coordinate
17: Robot coordinate
18: User coordinate
19: Tool coordinate
X coordinate value (unit: μ m )
Y coordinate value (unit: μ m )
Z coordinate value (unit: μ m )
Tx coordinate value
(unit: 0.0001 degree)
Ty coordinate value
(unit: 0.0001 degree)
Tz coordinate value
(unit: 0.0001 degree)
Reservation
19
20
21
22
23
24
25
26
Reservation
Type
Expanded type
Tool No. (0 to 63)
User coordinate No. (1 to 63)
Base 1st axis position (unit: μ m )
Base 2nd axis position (unit: μ m )
Base 3rd axis position (unit: μ m )
Station 1st axis position
(pulse value)
Station 2nd axis position
(pulse value)
Station 3rd axis position
(pulse value)
Station 4th axis position
(pulse value)
Station 5th axis position
(pulse value)
Station 6th axis position
(pulse value)
Refer to following data at the next page for details
Up to three axes
3-82
101 of 119
HW1480958
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Form bit0 0: Front bit1 0: Upper arm bit2 0: Flip bit3 0: ө R<180, bit4 0: ө T<180, bit5 0: ө S<180, bit6 Reserve bit7 Reserve
Details of data
Please refer to section 3.9.5 “Flip/ No flip” in “DX100 OPERATOR’S
MANUAL” prepared for each application.
1: Back 1: ө L ≥ 180
1: Lower arm
1:No flip
1: ө R ≥ 180
1: ө T ≥ 180
1: ө S ≥ 180
Extended form bit0 0: ө L<180, bit1 0: ө U<180, bit2 0: ө B<180, bit3 0: ө E<180, bit4 0: ө W<180, bit5 Reserve bit6 Reserve bit7 Reserve
1:
1:
1:
1: ө U ≥ 180 ө B ≥ 180 ө E ≥ 180 ө W ≥ 180
NOTE
To move the base axis, specify the robot No. at the specifying control group, and input the current value to the following coordinate values.
• X coordinate value (unit: μ m )
• Y coordinate value (unit: μ m )
• Z coordinate value (unit: μ m )
• Tx coordinate value (unit: 0.0001 degree)
• Ty coordinate value (unit: 0.0001 degree)
• Tz coordinate value (unit: 0.0001 degree)
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: not specified
•
1: 1 WORD
•
2: 2 WORD
Error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
No data part
3-83
HW1480958
102 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
3.3.40 Move Instruction Command (Type Pulse)
Request
Sub header part
<Details>
Command No.
0x8B
Instance Specify one out of followings
1:Link absolute position operation
2:Straight absolute position operation
Specify the operation number from one to three.
1:Link absolute position operation
2:Straight absolute position operation
Attribute
Service
Fixed to “1”
•
Set_Attribute_All: 0x02
Specify “1”.
Specify the accessing method to the data.
0x02: Write the data to the specified coordinate.
NOTE
It is not able to operate the robot and the station at the same time. Setting the both operation at the same time receives the control group setting error (0xB008) from the
DX100.
3-84
103 of 119
HW1480958
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
Data part
14
15
16
17
10
11
12
13
8
9
6
7
2
3
32bit integer Byte 0 Byte 1 Byte 2 Byte3 <Details>
1 Specifying control group (Robot) 1 to 8 (Robot No.)
4
5
Specifying control group (Station) 1 to 24 (Station No.)
Specifying the classification in speed Specify the classification of operations
0: % (Link operation)
1: V (Cartesian operation)
2: VR (Cartesian operation)
Specifying a speed
Robot 1st axis pulse value
Specify the rate
Link Operation : 0.01%
Cartesian operation V speed : 0.1 mm/s
Cartesian operation VR speed : 0.1 degree/s
Robot 2nd axis pulse value
Robot 3rd axis pulse value
Robot 4th axis pulse value
Robot 5thaxis pulse value
18
Robot 6th axis pulse value
Robot 7th axis pulse value
Robot 8th axis pulse value
Tool No. (0 to 63)
Base 1st axis position (Pulse value)
Base 2nd axis position (Pulse value)
Base 3rdaxis position (Pulse value)
Station 1st axis position
(pulse value)
Station 2nd axis position
(pulse value)
Up to three axes
19
20
21
22
Station 3rdaxis position
(pulse value)
Station 4th axis position
(pulse value)
Station 5th axis position
(pulse value)
Station 6th axis position
(pulse value)
162529-1CD
3-85
HW1480958
104 of 119
162529-1CD
DX100 3 Transmission Procedure
3.3 Respective Commands for Robot Control
NOTE
To move the base axis, specify the robot No. at the specifying control group, and input the each axis value.
• Robot 1st axis pulse value
• Robot 2ndt axis pulse value
• Robot 3rd axis pulse value
• Robot 4th axis pulse value
• Robot 5th axis pulse value
• Robot 6th axis pulse value
• Robot 7th axis pulse value
• Robot 8th axis pulse value
Status
Added status size
Added status
Answer
Sub header part
<Details>
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
•
0: not specified
•
1: 1 WORD
•
2: 2 WORD
Error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
No data part
NOTE
It is not able to operate the robot and the station at the same time. Setting the both operation at the same time receives the control group setting error (0xB008) from the
DX100.
3-86
105 of 119
HW1480958
DX100
162529-1CD
3 Transmission Procedure
3.4 File Control Command
3.4
File Control Command
Followings are respective commands used in the high-speed Ethernet communication.
Table 3-2: List of File Control Command
No. Command No. Instance Attribute Service Command name
1 0x0 0x0 0x0 0x09 File delete
2
3
4
5
0x15
0x16
0x32
0x16
File loading command
(the PC to the DX100)
File saving command
(the DX100 to the PC)
File list acquiring command
File saving command
(A batch data backup)
(the DX100 to the
PC)
1)
1 This command is available for system software version DS3.00 or higher.
Reference
Refer to
.
Refer to
.
Refer to
.
Refer to
Refer to
3-87
HW1480958
106 of 119
162529-1CD
DX100 3 Transmission Procedure
3.4 File Control Command
Command No.
0x0
Instance
Attribute
Service
0x0
0x0
0x09
3.4.1 File Deleting Command
Request
Sub header part
<Details>
File deleting process
32bit integer Byte 0
T
J
J
Data part
O
B
Byte 1
E
I
B
Byte 2
S
.
Byte3
T
<Details>
Specify the job name to be deleted
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
No data part
3-88
107 of 119
HW1480958
162529-1CD
DX100 3 Transmission Procedure
3.4 File Control Command
Command No.
0x0
Instance
Attribute
Service
0x0
0x0
0x15
3.4.2 File Loading Command
Request
Sub header part
<Details>
File loading process
32bit integer Byte 0
T
J
J
Data part
O
B
Byte 1
E
I
B
Byte 2
S
.
Byte3
T
<Details>
Specify the job name to be loaded
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
No data part
3-89
HW1480958
108 of 119
162529-1CD
DX100 3 Transmission Procedure
3.4 File Control Command
Command No.
0x0
Instance
Attribute
Service
0x0
0x0
0x16
3.4.3 File Saving Command
Request
Sub header part
<Details>
File saving process
32bit integer Byte 0
T
J
J
Data part
O
B
Byte 1
E
I
B
Byte 2
S
.
Byte3
T
<Details>
Specify the job names to be saved.
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
No data part
3-90
109 of 119
HW1480958
162529-1CD
DX100 3 Transmission Procedure
3.4 File Control Command
Command No.
0x0
Instance
Attribute
Service
0x0
0x0
0x32
3.4.4 File List Acquiring Command
Request
Sub header part
<Details>
File list accruing process
32bit integer Byte 0
*
I
Data part
.
Byte 1 Byte 2
J
Byte3
B
<Details>
Refer to “Details of data” for the file type.
Details of data
No specification JBI list
*.*
*.JBI
JBI list
JBI list
*.DAT
*.CND
*.PRM
*.SYS
*.LST
DAT file list
CND file list
PRM file list
SYS file list
LST file list
Answer
Sub header part
<Details>
Status Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
3-91
HW1480958
110 of 119
162529-1CD
DX100 3 Transmission Procedure
3.4 File Control Command
Data part
32bit integer Byte 0
I
1
3
B
I
2
T
0
B I
E
1
Byte 1
.
<CR>
I
3
.
<CR>
Byte 2
J
<LF>
J
<LF>
.
<CR>
.
S
<CR>
Byte3
B
2
B
3
J
<LF>
T
J
<LF>
<Details>
File name + <CR><LF> to input consecutively
3-92
111 of 119
HW1480958
162529-1CD
DX100 3 Transmission Procedure
3.4 File Control Command
Command No.
0x0
Instance
Attribute
Service
0x0
0x0
0x16
3.4.5 File Saving Command (The Batch Data Backup)
Request
Sub header part
<Details>
File saving process
32bit integer Byte 0
/
R
M
K
N
Data part
.
V
O
Byte 1
S
/
S
Byte 2
P
B I
C
B
Byte3
D
<Details>
Specify /SPDRV/CMOSBK.BIN
Answer
Sub header part
<Details>
Instance
Status
0x96
Respond by one in the followings
•
0x00 : respond normally
•
Other than 0x00
: respond abnormally
Added status size
•
0: no added status
•
1: 1 WORD
•
2: 2 WORD
Added status The error code specified by the added status size
“1” indicates 1 WORD of added status data, and “2” indicates 2 WORD of added status data.
The error code of 1 WORD exists if the added status code is “1” and that of 2 WORD exists if the code is “2”.
Data part
No data part
NOTE
To set the batch data backup function, set the device as
“RAMDISK” as in advance.
It takes about ten minutes to finish backing-up the data by using the batch data backup function.
Refer to
section 2.5 “Setting of a Batch Data Backup
3-93
HW1480958
112 of 119
162529-1CD
DX100
4 Error Code
4 Error Code
The following table is the message list of the status.
Added status code
0x08
0x09
0x1f
0x28
Details
Requested command is not defined
The element number of the invalid data is detected
An error inherent in vendor occurred
(CIP communication protocol corresponds to the vendor specification error)
Refer to chapter 5 “Added Status Code” for more
details.
An array number of the requested data does not exist in the specified command.
4-1
113 of 119
HW1480958
162529-1CD
DX100 5 Added Status Code
5 Added Status Code
3420
3430
3450
3460
4010
4012
3010
3040
3050
3070
3220
3230
3350
3360
3370
3380
3390
3400
3410
The following table is the message list of the added status.
Added status code
2040
2050
2060
2070
2080
2090
2100
2110
1010
1011
1012
1013
1020
2010
2020
2030
2120
2130
2150
4020
4030
Details
Command error
Error in number of command operands
Command operand value range over
Command operand length error
Disk full of files
Manipulator operating
Hold by programming pendant
Hold by playback panel
External hold
Command hold
Error/alarm occurring
Servo OFF
Incorrect mode
File accessing by other function
Command remote not set
This data cannot be accessed
This data cannot be loaded
Editing
Running the coordinate conversion function
*Refer to the NOTE in the last page of this list.
Turn ON the servo power
Perform home positioning
Confirm positions
Current value not made
Panel lock; mode/cycle prohibit signal is ON
Panel lock; start prohibit signal is ON
User coordinate is not taught
User coordinate is destroyed
Incorrect control group
Incorrect base axis data
Relative job conversion prohibited (at CVTRJ)
Master job call prohibited (parameter)
Master job call prohibited
(lamp ON during operation)
Master job call prohibited (teach lock)
Robot calibration data not defined
Servo power cannot be turned ON
Coordinate system cannot be set
Insufficient memory capacity (job registered memory)
Insufficient memory capacity
(position data registered memory)
Job editing prohibited
Same job name exists
5-1
HW1480958
114 of 119
162529-1CD
DX100 5 Added Status Code
Added status code
5430
5480
6010
6020
6030
6040
6050
6060
5120
5130
5170
5180
5200
5310
5340
5370
5390
4190
4200
4230
4420
4430
4480
4490
5110
4040
4060
4120
4130
4140
4150
4170
6070
6080
6090
6100
6110
6120
6130
6140
A000
A001
A002
A101
B001
Details
No specified job
Set an execution job
Position data is destroyed
Position data not exist
Incorrect position variable type
END instruction for job which is not master job
Instruction data is destroyed
Invalid character in job name
Invalid character in the label name
Invalid instruction in this system
No step in job to be converted
Already converted
Teach user coordinate
Relative job/ independent control function not permitted
Syntax error (syntax of instruction)
Position data error
No NOP or END
Format error (incorrect format)
Incorrect number of data
Data range over
Syntax error (except instruction)
Error in pseudo instruction specification
Error in condition file data record
Error in JOB data record
System data not same
Incorrect welding function type
The robot/station is under the operation
Not enough memory of the specified device
Cannot be accessed to the specified device
Unexpected auto backup request
CMOS size is over the RAM area
No memory allocation at the power supply on
Accessing error to backup file information
Failed in sorting backup file (Remove)
Failed in sorting backup file (Rename)
Drive name exceeds the specified values
Incorrect device
System error
Auto backup is not available
Cannot be backed up under the auto backup
Undefined command
Instance error
Attribute error
Replying data part size error (hardware limit)
Replying data part size error (software limit)
5-2
115 of 119
HW1480958
DX100
162529-1CD
5 Added Status Code
Added status code
B009
B00A
B00B
B00C
B00D
B00E
C001
C002
B002
B003
B004
B005
B006
B007
B008
C003
C800
CFFF
D8FA
D8F1
E24F
E250
E2B0
E2B1
E2B2
E2B3
E2B4
E444
E49D
E49E
E49F
E4A1
E4A2
E289
E28A
E28B
E28C
E29D
E29E
E29F
E2A0
E2AA
E2AF
Details
Data use prohibited
Requiring data size error
Outside the data
Data undefined
Specified application unregistered
Specified type unregistered
Control group setting error
Speed setting error
Operating speed is not setting
Operation coordinate system setting error
Type setting error
Tool No. setting error
User No. setting error
Address error
System error
System error
System error
Other error
Transmission exclusive error
(BUSY or Semaphore error)
Processing the another command (BUSY condition)
Parameter setting wrong for the system backup
System backup file creating error
(confirm if the mode is the remote mode)
System error
System error
Disconnect the communication due to receive timeout
Cannot over write the target file
System error
System error
System error
The wrong required pass
System error
Receive the deletion request of the file that cannot to delete
System error
The directory cannot to be deleted
System error
File not found
The requested pass is too long
Processing the another command (BUSY condition)
Format error (data size 0)
Format error (frame size over)
Format error (frame size 0)
Format error (block number error)
Format error (ACK error)
5-3
HW1480958
116 of 119
162529-1CD
DX100 5 Added Status Code
E4A8
E4A9
FFF0
FFF2
FFF3
FFF4
FFF5
FFF6
FFF7
FFF8
FFFE
Added status code
E4A3
E4A4
E4A5
E4A6
E4A7
Details
Format error (processing category error)
Format error (access level error)
Format error (header size error)
Format error (identifier error)
Format error (the size of the requested command and received frame are different)
System error
System error
System error
System error
System error
System error
System error
Too many request and unable to process
(BUSY condition)
System error
System error
The remote mode is detected, and disconnect the communication
NOTE
• Added status code 2150: Running the coordinate conversion function
This error occurs when executes the axis configuration information reading command at the following screen displays.
• Parallel shift job conversion display
• Mirror shift conversion display
• PAM display
• Relative job conversion display
• PMT conversion display
• Position modification display
• Arm bend compensate display
• User coordinate shift display
• Gun teaching position modification display
• 4 point teaching display
It is not only conditions above, but also the error occurs while executing the PMT instruction.
5-4
117 of 119
HW1480958
DX100
162529-1CD
5 Added Status Code
NOTE
When the DX100 returning the system error, perform the following procedures.
1: Reset the alarm.
2: Save the CMOS.BIN, and report the occurrence of the
alarm to YASKAWA service representative.
5-5
HW1480958
118 of 119
DX100 OPTIONS
INSTRUCTIONS
FOR HIGH-SPEED ETHERNET SERVER FUNCTION
HEAD OFFICE
2-1 Kurosakishiroishi, Yahatanishi-ku, Kitakyushu 806-0004, Japan
Phone +81-93-645-7703 Fax +81-93-645-7802
YASKAWA America Inc. (Motoman Robotics Division)
100 Automation Way, Miamisburg, OH 45342, U.S.A.
Phone +1-937-847-6200 Fax +1-937-847-6277
YASKAWA Europe GmbH Robotics Divsion )
Yaskawastrasse 1, 85391 Allershausen, Germany
Phone +49-8166-90-100 Fax +49-8166-90-103
YASKAWA Nordic AB
Verkstadsgatan 2, Box 504 ,SE-385 25 Torsas, Sweden
Phone +46-480-417-800 Fax +46-486-414-10
YASKAWA Electric (China) Co., Ltd.
22F, One Corporate Avenue, No.222, Hubin Road, Huangpu District, Shanghai 200021, China
Phone +86-21-5385-2200 Fax 㸩 86-21-5385-3299
YASKAWA SHOUGANG ROBOT Co. Ltd.
No7 Yongchang North Road, Beijing E&T Development Area China 100176
Phone +86-10-6788-2858 Fax +86-10-6788-2878
YASKAWA India Private Ltd. (Robotics Division)
#426, Udyog Vihar, Phase- IV, Gurgaon, Haryana, India
Phone +91-124-475-8500 Fax +91-124-475-8542
YASKAWA Electric Korea Corporation
35F, Three IFC, 10 Gukjegeumyung-ro, Yeongdeungpo-gu, Seoul, Korea 07326
Phone +82-2-784-7844 Fax +82-2-784-8495
YASKAWA Electric Taiwan Corporation
12F, No.207, Sec. 3, Beishin Rd., Shindian District, New Taipei City 23143, Taiwan
Phone +886-2-8913-1333 Fax +886-2-8913-1513
YASKAWA Electric (Singapore) PTE Ltd.
151 Lorong Chuan, #04-02A, New Tech Park, Singapore 556741
Phone +65-6282-3003 Fax +65-6289-3003
YASKAWA Electric (Thailand) Co., Ltd.
59,1st-5th Floor, Flourish Building, Soi Ratchadapisek 18,Ratchadapisek Road,
Huaykwang, Bangkok 10310, THAILAND
Phone +66-2-017-0099 Fax +66-2-017-0199
PT. YASKAWA Electric Indonesia
Secure Building-Gedung B Lantai Dasar & Lantai 1 JI. Raya Protokol Halim Perdanakusuma,
Jakarta 13610, Indonesia
Phone +62-21-2982-6470 Fax +62-21-2982-6741
Specifications are subject to change without notice for ongoing product modifications and improvements.
119 of 119
MANUAL NO.
HW1480958
6
Herunterladen